CISCO-MPLS-TE-STD-EXT-MIB

File: CISCO-MPLS-TE-STD-EXT-MIB.mib (24022 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
MPLS-TE-STD-MIB CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Gauge32 Unsigned32 MODULE-COMPLIANCE
OBJECT-GROUP TEXTUAL-CONVENTION mplsTunnelIndex
mplsTunnelInstance mplsTunnelIngressLSRId mplsTunnelEgressLSRId
ciscoMgmt

Defined Objects

cmplsTeStdExtMIB 1.3.6.1.4.1.9.9.738
This MIB module contains Cisco specific managed object definitions for MPLS Traffic Engineering (TE), not contained in MPLS-TE-STD-MIB. The auto bandwidth feature enables MPLS TE Tunnels to adapt automatically their bandwidth to their actual load.
MODULE-IDENTITY    

cmplsTeStdExtMIBNotifs 1.3.6.1.4.1.9.9.738.0
OBJECT IDENTIFIER    

cmplsTeStdExtMIBObjects 1.3.6.1.4.1.9.9.738.1
OBJECT IDENTIFIER    

cmplsTunnelAutoBWTable 1.3.6.1.4.1.9.9.738.1.1
This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTunnelEntry with a mplsTunnelRole of 'head' or 'headTail'. Each row contains auto-bandwidth data for the tunnel identified by the indexes defined later. An entry is created as soon as a 'head' or 'headTail' MPLS TE tunnel is configured in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    CmplsTunnelAutoBWEntry

cmplsTunnelAutoBWEntry 1.3.6.1.4.1.9.9.738.1.1.1
A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'.
OBJECT-TYPE    
  CmplsTunnelAutoBWEntry  

cmplsTunnelAutoBWStatus 1.3.6.1.4.1.9.9.738.1.1.1.1
This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBWEnabled: The auto-bandwidth algorithm is running; - autoBWCollectOnlyMode: The auto-bandwidth algorithm is running, but the bandwidth applications are disabled;
OBJECT-TYPE    
  INTEGER autoBWDisabled(1), autoBWEnabled(2), autoBWCollectOnlyMode(3)  

cmplsTunnelAutoBWMin 1.3.6.1.4.1.9.9.738.1.1.1.2
This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWMax 1.3.6.1.4.1.9.9.738.1.1.1.3
This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWAdjThreshPercs 1.3.6.1.4.1.9.9.738.1.1.1.4
This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  CmplsTunnelBWPercent  

cmplsTunnelAutoBWAdjThreshBW 1.3.6.1.4.1.9.9.738.1.1.1.5
This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWOverflowThreshPercs 1.3.6.1.4.1.9.9.738.1.1.1.6
This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  CmplsTunnelBWPercent  

cmplsTunnelAutoBWOverflowThreshBW 1.3.6.1.4.1.9.9.738.1.1.1.7
This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWOverflowLimit 1.3.6.1.4.1.9.9.738.1.1.1.8
This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWUnderflowThreshPercs 1.3.6.1.4.1.9.9.738.1.1.1.9
This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  CmplsTunnelBWPercent  

cmplsTunnelAutoBWUnderflowThreshBW 1.3.6.1.4.1.9.9.738.1.1.1.10
This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWUnderflowLimit 1.3.6.1.4.1.9.9.738.1.1.1.11
This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWApplicationFrequency 1.3.6.1.4.1.9.9.738.1.1.1.12
This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWCollectionFrequency 1.3.6.1.4.1.9.9.738.1.1.1.13
This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWLastAppliedBW 1.3.6.1.4.1.9.9.738.1.1.1.14
This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWApplications 1.3.6.1.4.1.9.9.738.1.1.1.15
This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWLastApplicationTrigger 1.3.6.1.4.1.9.9.738.1.1.1.16
This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  INTEGER applicationNone(1), applicationPeriodic(2), applicationManual(3), applicationOverflow(4), applicationUnderflow(5)  

cmplsTunnelAutoBWOverflowApplications 1.3.6.1.4.1.9.9.738.1.1.1.17
This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWOverflowOccurrences 1.3.6.1.4.1.9.9.738.1.1.1.18
This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWUnderflowApplications 1.3.6.1.4.1.9.9.738.1.1.1.19
This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWUnderflowOccurrences 1.3.6.1.4.1.9.9.738.1.1.1.20
This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWUnderflowHighestBW 1.3.6.1.4.1.9.9.738.1.1.1.21
This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Gauge32  

cmplsTunnelAutoBWRequested 1.3.6.1.4.1.9.9.738.1.1.1.22
This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWSignaled 1.3.6.1.4.1.9.9.738.1.1.1.23
This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWCollectOnlyRequested 1.3.6.1.4.1.9.9.738.1.1.1.24
This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the collect only mode is enabled, the bandwidth change request will not be executed. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWHighest 1.3.6.1.4.1.9.9.738.1.1.1.25
This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWCollectedSamples 1.3.6.1.4.1.9.9.738.1.1.1.26
This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Counter32  

cmplsTunnelAutoBWJitter 1.3.6.1.4.1.9.9.738.1.1.1.27
This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth is applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  Unsigned32  

cmplsTunnelAutoBWAppRejectReason 1.3.6.1.4.1.9.9.738.1.1.1.28
This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'.
OBJECT-TYPE    
  INTEGER applicationAllowed(1), autoBWDisabled(2), tunnelIsDown(3), tunnelIsFRR(4), tunnelIsBackup(5), tunnelIsLockDown(6)  

cmplsTeStdExtMIBConform 1.3.6.1.4.1.9.9.738.2
OBJECT IDENTIFIER    

cmplsTeStdExtMIBCompliances 1.3.6.1.4.1.9.9.738.2.1
OBJECT IDENTIFIER    

cmplsTeStdExtMIBCompliance 1.3.6.1.4.1.9.9.738.2.1.1
This is the main compliance statement for the MIB.
MODULE-COMPLIANCE    

cmplsTeStdExtMIBGroups 1.3.6.1.4.1.9.9.738.2.2
OBJECT IDENTIFIER    

cmplsTeStdExtMIBAutoBWObjectGroup 1.3.6.1.4.1.9.9.738.2.2.1
This contains the main MPLS TE extensions groups.
OBJECT-GROUP    

cmplsTeStdExtMIBAutoBWOptionalGroup 1.3.6.1.4.1.9.9.738.2.2.2
This contains the optional MPLS TE extensions groups.
OBJECT-GROUP    

Defined Objects

CmplsTunnelBWPercent  
A fraction of the bandwidth expressed in percentage.
TEXTUAL-CONVENTION    
  Unsigned32 0..100  

CmplsTunnelAutoBWEntry  
SEQUENCE    
  INTEGER as cmplsTunnelAutoBWStatus  
  Unsigned32 as cmplsTunnelAutoBWMin  
  Unsigned32 as cmplsTunnelAutoBWMax  
  CmplsTunnelBWPercent as cmplsTunnelAutoBWAdjThreshPercs  
  Unsigned32 as cmplsTunnelAutoBWAdjThreshBW  
  CmplsTunnelBWPercent as cmplsTunnelAutoBWOverflowThreshPercs  
  Unsigned32 as cmplsTunnelAutoBWOverflowThreshBW  
  Unsigned32 as cmplsTunnelAutoBWOverflowLimit  
  CmplsTunnelBWPercent as cmplsTunnelAutoBWUnderflowThreshPercs  
  Unsigned32 as cmplsTunnelAutoBWUnderflowThreshBW  
  Unsigned32 as cmplsTunnelAutoBWUnderflowLimit  
  Unsigned32 as cmplsTunnelAutoBWApplicationFrequency  
  Unsigned32 as cmplsTunnelAutoBWCollectionFrequency  
  Unsigned32 as cmplsTunnelAutoBWLastAppliedBW  
  Counter32 as cmplsTunnelAutoBWApplications  
  INTEGER as cmplsTunnelAutoBWLastApplicationTrigger  
  Counter32 as cmplsTunnelAutoBWOverflowApplications  
  Counter32 as cmplsTunnelAutoBWOverflowOccurrences  
  Counter32 as cmplsTunnelAutoBWUnderflowApplications  
  Counter32 as cmplsTunnelAutoBWUnderflowOccurrences  
  Gauge32 as cmplsTunnelAutoBWUnderflowHighestBW  
  Unsigned32 as cmplsTunnelAutoBWRequested  
  Unsigned32 as cmplsTunnelAutoBWSignaled  
  Unsigned32 as cmplsTunnelAutoBWCollectOnlyRequested  
  Unsigned32 as cmplsTunnelAutoBWHighest  
  Counter32 as cmplsTunnelAutoBWCollectedSamples  
  Unsigned32 as cmplsTunnelAutoBWJitter  
  INTEGER as cmplsTunnelAutoBWAppRejectReason