| SNMPv2-SMI | SNMPv2-CONF | SNMPv2-TC |
| MPLS-TE-STD-MIB | CISCO-SMI |
| MODULE-IDENTITY | OBJECT-TYPE | Counter32 |
| Gauge32 | Unsigned32 | MODULE-COMPLIANCE |
| OBJECT-GROUP | TEXTUAL-CONVENTION | mplsTunnelIndex |
| mplsTunnelInstance | mplsTunnelIngressLSRId | mplsTunnelEgressLSRId |
| ciscoMgmt |
| cmplsTeStdExtMIB | 1.3.6.1.4.1.9.9.738 | ||
| This MIB module contains Cisco specific managed object definitions for MPLS Traffic Engineering (TE), not contained in MPLS-TE-STD-MIB. The auto bandwidth feature enables MPLS TE Tunnels to adapt automatically their bandwidth to their actual load. | |||
| MODULE-IDENTITY | |||
| cmplsTeStdExtMIBNotifs | 1.3.6.1.4.1.9.9.738.0 | ||
| OBJECT IDENTIFIER | |||
| cmplsTeStdExtMIBObjects | 1.3.6.1.4.1.9.9.738.1 | ||
| OBJECT IDENTIFIER | |||
| cmplsTunnelAutoBWTable | 1.3.6.1.4.1.9.9.738.1.1 | ||
| This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTunnelEntry with a mplsTunnelRole of 'head' or 'headTail'. Each row contains auto-bandwidth data for the tunnel identified by the indexes defined later. An entry is created as soon as a 'head' or 'headTail' MPLS TE tunnel is configured in the system. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmplsTunnelAutoBWEntry | |||
| cmplsTunnelAutoBWEntry | 1.3.6.1.4.1.9.9.738.1.1.1 | ||
| A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'. | |||
| OBJECT-TYPE | |||
| CmplsTunnelAutoBWEntry | |||
| cmplsTunnelAutoBWStatus | 1.3.6.1.4.1.9.9.738.1.1.1.1 | ||
| This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBWEnabled: The auto-bandwidth algorithm is running; - autoBWCollectOnlyMode: The auto-bandwidth algorithm is running, but the bandwidth applications are disabled; | |||
| OBJECT-TYPE | |||
| INTEGER | autoBWDisabled(1), autoBWEnabled(2), autoBWCollectOnlyMode(3) | ||
| cmplsTunnelAutoBWMin | 1.3.6.1.4.1.9.9.738.1.1.1.2 | ||
| This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWMax | 1.3.6.1.4.1.9.9.738.1.1.1.3 | ||
| This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWAdjThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.4 | ||
| This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| CmplsTunnelBWPercent | |||
| cmplsTunnelAutoBWAdjThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.5 | ||
| This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWOverflowThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.6 | ||
| This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| CmplsTunnelBWPercent | |||
| cmplsTunnelAutoBWOverflowThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.7 | ||
| This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWOverflowLimit | 1.3.6.1.4.1.9.9.738.1.1.1.8 | ||
| This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWUnderflowThreshPercs | 1.3.6.1.4.1.9.9.738.1.1.1.9 | ||
| This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| CmplsTunnelBWPercent | |||
| cmplsTunnelAutoBWUnderflowThreshBW | 1.3.6.1.4.1.9.9.738.1.1.1.10 | ||
| This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWUnderflowLimit | 1.3.6.1.4.1.9.9.738.1.1.1.11 | ||
| This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWApplicationFrequency | 1.3.6.1.4.1.9.9.738.1.1.1.12 | ||
| This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWCollectionFrequency | 1.3.6.1.4.1.9.9.738.1.1.1.13 | ||
| This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWLastAppliedBW | 1.3.6.1.4.1.9.9.738.1.1.1.14 | ||
| This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWApplications | 1.3.6.1.4.1.9.9.738.1.1.1.15 | ||
| This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWLastApplicationTrigger | 1.3.6.1.4.1.9.9.738.1.1.1.16 | ||
| This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| INTEGER | applicationNone(1), applicationPeriodic(2), applicationManual(3), applicationOverflow(4), applicationUnderflow(5) | ||
| cmplsTunnelAutoBWOverflowApplications | 1.3.6.1.4.1.9.9.738.1.1.1.17 | ||
| This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWOverflowOccurrences | 1.3.6.1.4.1.9.9.738.1.1.1.18 | ||
| This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWUnderflowApplications | 1.3.6.1.4.1.9.9.738.1.1.1.19 | ||
| This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWUnderflowOccurrences | 1.3.6.1.4.1.9.9.738.1.1.1.20 | ||
| This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWUnderflowHighestBW | 1.3.6.1.4.1.9.9.738.1.1.1.21 | ||
| This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Gauge32 | |||
| cmplsTunnelAutoBWRequested | 1.3.6.1.4.1.9.9.738.1.1.1.22 | ||
| This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWSignaled | 1.3.6.1.4.1.9.9.738.1.1.1.23 | ||
| This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWCollectOnlyRequested | 1.3.6.1.4.1.9.9.738.1.1.1.24 | ||
| This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the collect only mode is enabled, the bandwidth change request will not be executed. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWHighest | 1.3.6.1.4.1.9.9.738.1.1.1.25 | ||
| This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWCollectedSamples | 1.3.6.1.4.1.9.9.738.1.1.1.26 | ||
| This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cmplsTunnelAutoBWJitter | 1.3.6.1.4.1.9.9.738.1.1.1.27 | ||
| This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth is applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cmplsTunnelAutoBWAppRejectReason | 1.3.6.1.4.1.9.9.738.1.1.1.28 | ||
| This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. | |||
| OBJECT-TYPE | |||
| INTEGER | applicationAllowed(1), autoBWDisabled(2), tunnelIsDown(3), tunnelIsFRR(4), tunnelIsBackup(5), tunnelIsLockDown(6) | ||
| cmplsTeStdExtMIBConform | 1.3.6.1.4.1.9.9.738.2 | ||
| OBJECT IDENTIFIER | |||
| cmplsTeStdExtMIBCompliances | 1.3.6.1.4.1.9.9.738.2.1 | ||
| OBJECT IDENTIFIER | |||
| cmplsTeStdExtMIBCompliance | 1.3.6.1.4.1.9.9.738.2.1.1 | ||
| This is the main compliance statement for the MIB. | |||
| MODULE-COMPLIANCE | |||
| cmplsTeStdExtMIBGroups | 1.3.6.1.4.1.9.9.738.2.2 | ||
| OBJECT IDENTIFIER | |||
| cmplsTeStdExtMIBAutoBWObjectGroup | 1.3.6.1.4.1.9.9.738.2.2.1 | ||
| This contains the main MPLS TE extensions groups. | |||
| OBJECT-GROUP | |||
| cmplsTeStdExtMIBAutoBWOptionalGroup | 1.3.6.1.4.1.9.9.738.2.2.2 | ||
| This contains the optional MPLS TE extensions groups. | |||
| OBJECT-GROUP | |||
| CmplsTunnelBWPercent | |||
| A fraction of the bandwidth expressed in percentage. | |||
| TEXTUAL-CONVENTION | |||
| Unsigned32 | 0..100 | ||
| CmplsTunnelAutoBWEntry | |||
| SEQUENCE | |||
| INTEGER as cmplsTunnelAutoBWStatus | |||
| Unsigned32 as cmplsTunnelAutoBWMin | |||
| Unsigned32 as cmplsTunnelAutoBWMax | |||
| CmplsTunnelBWPercent as cmplsTunnelAutoBWAdjThreshPercs | |||
| Unsigned32 as cmplsTunnelAutoBWAdjThreshBW | |||
| CmplsTunnelBWPercent as cmplsTunnelAutoBWOverflowThreshPercs | |||
| Unsigned32 as cmplsTunnelAutoBWOverflowThreshBW | |||
| Unsigned32 as cmplsTunnelAutoBWOverflowLimit | |||
| CmplsTunnelBWPercent as cmplsTunnelAutoBWUnderflowThreshPercs | |||
| Unsigned32 as cmplsTunnelAutoBWUnderflowThreshBW | |||
| Unsigned32 as cmplsTunnelAutoBWUnderflowLimit | |||
| Unsigned32 as cmplsTunnelAutoBWApplicationFrequency | |||
| Unsigned32 as cmplsTunnelAutoBWCollectionFrequency | |||
| Unsigned32 as cmplsTunnelAutoBWLastAppliedBW | |||
| Counter32 as cmplsTunnelAutoBWApplications | |||
| INTEGER as cmplsTunnelAutoBWLastApplicationTrigger | |||
| Counter32 as cmplsTunnelAutoBWOverflowApplications | |||
| Counter32 as cmplsTunnelAutoBWOverflowOccurrences | |||
| Counter32 as cmplsTunnelAutoBWUnderflowApplications | |||
| Counter32 as cmplsTunnelAutoBWUnderflowOccurrences | |||
| Gauge32 as cmplsTunnelAutoBWUnderflowHighestBW | |||
| Unsigned32 as cmplsTunnelAutoBWRequested | |||
| Unsigned32 as cmplsTunnelAutoBWSignaled | |||
| Unsigned32 as cmplsTunnelAutoBWCollectOnlyRequested | |||
| Unsigned32 as cmplsTunnelAutoBWHighest | |||
| Counter32 as cmplsTunnelAutoBWCollectedSamples | |||
| Unsigned32 as cmplsTunnelAutoBWJitter | |||
| INTEGER as cmplsTunnelAutoBWAppRejectReason | |||