CISCO-SNA-LLC-MIB

File: CISCO-SNA-LLC-MIB.mib (107200 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RFC1213-MIB CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Counter32 Integer32 TimeTicks
Gauge32 DisplayString RowStatus
TimeStamp MacAddress MODULE-COMPLIANCE
OBJECT-GROUP ifIndex ciscoExperiment

Defined Objects

ciscoSnaLlcMIB 1.3.6.1.4.1.9.10.8
This is the MIB module for objects used to manage LLC devices.
MODULE-IDENTITY    

ciscoSnaLlcMIBObjects 1.3.6.1.4.1.9.10.8.1
OBJECT IDENTIFIER    

llcPortGroup 1.3.6.1.4.1.9.10.8.1.1
OBJECT IDENTIFIER    

llcPortAdminTable 1.3.6.1.4.1.9.10.8.1.1.1
This table contains objects that can be changed to manage an LLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortAdminEntry

llcPortAdminEntry 1.3.6.1.4.1.9.10.8.1.1.1.1
A list of configured values for an LLC port.
OBJECT-TYPE    
  LlcPortAdminEntry  

llcPortVirtualIndex 1.3.6.1.4.1.9.10.8.1.1.1.1.1
This value represents a virtual LLC port. It is assigned by the agent. This value is set to 0 by the agent for interfaces identified by the ifIndex value that do not support virtual interfaces.
OBJECT-TYPE    
  Integer32 0..65535  

llcPortAdminName 1.3.6.1.4.1.9.10.8.1.1.1.1.2
An octet string that defines the virtual port to which this interface is assigned. Its value shall be unique within the administered system. It must contain only ASCII printable characters. A write operation shall not take effect until the port is cycled inactive.
OBJECT-TYPE    
  DisplayString SIZE(1..8)  

llcPortAdminMaxSaps 1.3.6.1.4.1.9.10.8.1.1.1.1.3
This parameter specifies the maximum number of SAPs that can be defined for this port.
OBJECT-TYPE    
  Gauge32  

llcPortAdminMaxCcs 1.3.6.1.4.1.9.10.8.1.1.1.1.4
This parameter specifies the maximum number of connection components that can be administratively defined for this port.
OBJECT-TYPE    
  Gauge32  

llcPortAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.1.1.1.5
This object denotes the default maximum I PDU size, in octets, that LLCs on this port may send to their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsSend object or by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
OBJECT-TYPE    
  Integer32  

llcPortAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.1.1.1.6
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this port may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsSend object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.1.1.1.7
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsRcv object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.1.1.1.8
This object denotes the default value for the maximum number of times which LLCs on this port shall retry a PDU following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxretransmits object or by a non-zero value in the llcCcAdminMaxRetransmits object.
OBJECT-TYPE    
  Integer32  

llcPortAdminAckTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.9
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the unacknowledged frames to be retransmitted (up to N2 times). For Implementations that only use a single 'T1' Value (ref. IBM Token-Ring Network technical reference Chapter 11). This object will be used to control/read the value. This port default value may be overridden by a non-zero value in the llcSapAdminAckTimer object or by a non-zero value in the llcCcAdminAckTimer object.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.10
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the command with the poll bit to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminPbitTimer object or by a non-zero value in the llcCcAdminPbitTimer object.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminRejTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.11
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminRejTimer object or by a non-zero value in the llcCcAdminRejTimer object.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.12
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminBusyTimer object or by a non-zero value in the llcCcAdminBusyTimer object.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminInactTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.13
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture [6] Reference as the Ti parameter and is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. The value for llcPortAdminInactTimer must be much greater than the value for llcPortAdminDelayAckTimer. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminInactTimer object or by a non-zero value in the llcCcAdminInactTimer object. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.1.1.1.14
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this port shall receive during the interval defined by llcCcOperDelayTimertime without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the N3 parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminDelayAckCount object or by a non-zero value in the llcCcAdminDelayCount object. A value of one indicates that acknowledgments will be sent immediately and that the value of llcPortAdminDelayAckTimer shall be ignored.
OBJECT-TYPE    
  Integer32  

llcPortAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.15
This object denotes the default value for the time interval during which the LLCs on this port shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
OBJECT-TYPE    
  TimeTicks  

llcPortAdminNw 1.3.6.1.4.1.9.10.8.1.1.1.1.16
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminNw object.
OBJECT-TYPE    
  Integer32  

llcPortOperTable 1.3.6.1.4.1.9.10.8.1.1.2
This table contains current LLC port parameters. Many of these objects have corresponding objects in the llcPortAdminTable.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortOperEntry

llcPortOperEntry 1.3.6.1.4.1.9.10.8.1.1.2.1
Currently set parameters for a specific LLC port.
OBJECT-TYPE    
  LlcPortOperEntry  

llcPortOperMacAddress 1.3.6.1.4.1.9.10.8.1.1.2.1.1
This is the MAC Address for this local port.
OBJECT-TYPE    
  MacAddress  

llcPortOperNumSaps 1.3.6.1.4.1.9.10.8.1.1.2.1.2
This object defines the number of SAPs on this port that are currently enabled. In other words, this object is a count of the number of instances of llcSapOperEntry that have a llcSapOperStatus value of 'active(2)'.
OBJECT-TYPE    
  Gauge32  

llcPortOperHiWaterNumSaps 1.3.6.1.4.1.9.10.8.1.1.2.1.3
This object reflects the highest number of SAPs active on this Port simultaneously. In other words, this object is a count of the number of instances of llcSapOperEntry on this Port.
OBJECT-TYPE    
  Gauge32  

llcPortOperSimRim 1.3.6.1.4.1.9.10.8.1.1.2.1.4
This object reflects support for transmission and receipt of SIM and RIM control frames for this port. SIM and RIM are not defined in the ANSI/IEEE 802.2 specification [5] nor in the IBM Token Ring Architecture Reference [6]. These control frames are used for the remote program load of IBM communications processors.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcPortOperLastModifyTime 1.3.6.1.4.1.9.10.8.1.1.2.1.5
This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero.
OBJECT-TYPE    
  TimeStamp  

llcPortStatsTable 1.3.6.1.4.1.9.10.8.1.1.3
Each entry in this table contains statistics for a specific LLC port.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortStatsEntry

llcPortStatsEntry 1.3.6.1.4.1.9.10.8.1.1.3.1
A list of statistics for an LLC port.
OBJECT-TYPE    
  LlcPortStatsEntry  

llcPortStatsPDUsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.1
This object reflects the total number of PDUs that have been received on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

llcPortStatsPDUsOut 1.3.6.1.4.1.9.10.8.1.1.3.1.2
This object reflects the total number of PDUs that have been transmitted on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.3
This object reflects the total octets received on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsOut 1.3.6.1.4.1.9.10.8.1.1.3.1.4
This object reflects the total octets transmitted on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

llcPortStatsTESTCommandsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.5
This object reflects the total number of TEST commands received on this port.
OBJECT-TYPE    
  Counter32  

llcPortStatsTESTResponsesOut 1.3.6.1.4.1.9.10.8.1.1.3.1.6
This object reflects the total number of TEST responses transmitted on this port in response to TEST commands received.
OBJECT-TYPE    
  Counter32  

llcPortStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.1.3.1.7
This object reflects the total number of times that the local connection components on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

llcPortStatsUnknownSaps 1.3.6.1.4.1.9.10.8.1.1.3.1.8
This object reflects the total number of times that a connection attempt, from a remote LLC station, for an unknown SAP was detected on this port.
OBJECT-TYPE    
  Counter32  

llcSapGroup 1.3.6.1.4.1.9.10.8.1.2
OBJECT IDENTIFIER    

llcSapAdminTable 1.3.6.1.4.1.9.10.8.1.2.1
This table contains objects that can be changed to manage a local SAP. Changing one of these parameters may take effect in the operating CC immediately or may wait until the interface is restarted depending on the details of the implementation.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapAdminEntry

llcSapAdminEntry 1.3.6.1.4.1.9.10.8.1.2.1.1
A list of configured values for a local SAP.
OBJECT-TYPE    
  LlcSapAdminEntry  

llcSapNumber 1.3.6.1.4.1.9.10.8.1.2.1.1.1
The address of this local SAP.
OBJECT-TYPE    
  INTEGER 1..255  

llcSapAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.2.1.1.2
This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP may send to their remote connection component partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
OBJECT-TYPE    
  Integer32  

llcSapAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.2.1.1.3
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this SAP may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
OBJECT-TYPE    
  INTEGER 0..127  

llcSapAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.2.1.1.4
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
OBJECT-TYPE    
  INTEGER 0..127  

llcSapAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.2.1.1.5
This object denotes the default value for the maximum number of times that LLCs on this SAP shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxRetransmits, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxRetransmits.
OBJECT-TYPE    
  Integer32  

llcSapAdminAckTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.6
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminAckTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminAckTimer.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.7
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminPbitTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminPbitTimer.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminRejTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.8
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminRejTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminRejTimer.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.9
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. A zero value for this object indicates that the port default, llcPortAdminBusyTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminBusyTimer.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminInactTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.10
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. A zero value for this object indicates that the port default, llcPortAdminInactTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminInactTimer. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.2.1.1.11
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this SAP shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A zero value for this object indicates that the port default, llcPortAdminDelayAck, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminDelayAckCount. A value of one indicates that acknowledgments will be sent immediately and that the value of llcSapAdminDelayAckTimer shall be ignored.
OBJECT-TYPE    
  Integer32  

llcSapAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.12
This object denotes the default value for the time interval during which the LLCs on this SAP shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
OBJECT-TYPE    
  TimeTicks  

llcSapAdminNw 1.3.6.1.4.1.9.10.8.1.2.1.1.13
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This SAP default value may be overridden by a non-zero Cc default value in the llcCcAdminNw object.
OBJECT-TYPE    
  Integer32  

llcSapOperTable 1.3.6.1.4.1.9.10.8.1.2.2
This table contains objects that reflect the current operational parameters of a local SAP.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapOperEntry

llcSapOperEntry 1.3.6.1.4.1.9.10.8.1.2.2.1
A list of configured values for a local SAP.
OBJECT-TYPE    
  LlcSapOperEntry  

llcSapOperStatus 1.3.6.1.4.1.9.10.8.1.2.2.1.1
This parameter describes the actual state of this local SAP.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

llcSapOperNumCcs 1.3.6.1.4.1.9.10.8.1.2.2.1.2
This object defines the number of connection components on this SAP that are currently in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)'.
OBJECT-TYPE    
  Integer32  

llcSapOperHiWaterNumCcs 1.3.6.1.4.1.9.10.8.1.2.2.1.3
This object reflects the highest number of connection components on this SAP simultaneously in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)' concurrently on this SAP.
OBJECT-TYPE    
  Gauge32  

llcSapOperLlc2Support 1.3.6.1.4.1.9.10.8.1.2.2.1.4
This parameter describes whether or not the LLC implementation supports LLC2 connection components.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcSapStatsTable 1.3.6.1.4.1.9.10.8.1.2.3
This table contains objects that reflect the current operational parameters of a local SAP.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapStatsEntry

llcSapStatsEntry 1.3.6.1.4.1.9.10.8.1.2.3.1
A list of configured values for a local SAP.
OBJECT-TYPE    
  LlcSapStatsEntry  

llcSapStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.2.3.1.1
This object reflects the total number of times that the local connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsRemoteBusies 1.3.6.1.4.1.9.10.8.1.2.3.1.2
This object reflects the total number of times that the adjacent (i.e. remote) connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsIFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.3
This object reflects the total number of I-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsIFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.4
This object reflects the total number of I-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsIOctetsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.5
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsIOctetsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.6
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsSFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.7
This object reflects the total number of S-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
OBJECT-TYPE    
  Counter32  

llcSapStatsSFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.8
This object reflects the total number of S-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
OBJECT-TYPE    
  Counter32  

llcSapStatsRetransmitsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.9
This object reflects the total number of I-Frames retransmitted by all local connection components on this SAP. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsREJsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.10
This object reflects the total REJ frames received from all adjacent LLC connection components on this SAP since it was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsREJsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.11
This object reflects the total REJ frames transmitted to an adjacent LLC connection components on this SAP since it was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsWwCount 1.3.6.1.4.1.9.10.8.1.2.3.1.12
This object reflects the total number of times, since this SAP was created, that the dynamic window algorithm has been invoked to reduce the value of Ww on any of the connection components of this SAP. This object is initialized to zero when the SAP is created. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTCommandsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.13
This object denotes the number of TEST commands this SAP has received and is a measure of the number of stations in the network trying to connect up. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTCommandsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.14
This object denotes the number of TEST commands this SAP has sent and is a measure of the number of other stations we are trying to connect to. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTResponsesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.15
This object denotes the number of TEST responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTResponsesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.16
This object denotes the number of TEST responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDCommandsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.17
This object denotes the number of XID commands this SAP has received and is a measure of the number of stations in the network trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDCommandsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.18
This object denotes the number of XID commands this SAP has sent and is a measure of the number of other stations this SAP is trying to connect to. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDResponsesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.19
This object denotes the number of XID responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDResponsesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.20
This object denotes the number of XID responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.21
This object reflects the total number of unnumbered information (UI) frames received on a local SAP.
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.22
This object reflects the total number of unnumbered information (UI) frames sent on a local SAP.
OBJECT-TYPE    
  Counter32  

llcSapStatsUIOctetsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.23
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsUIOctetsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.24
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
OBJECT-TYPE    
  Counter32  

llcSapStatsConnectOk 1.3.6.1.4.1.9.10.8.1.2.3.1.25
This object reflects the total number of successful connections that have been established on this SAP since the SAP was created. A successful connection is indicated by a successful SABME/UA exchange.
OBJECT-TYPE    
  Counter32  

llcSapStatsConnectFail 1.3.6.1.4.1.9.10.8.1.2.3.1.26
This object reflects the total number of unsuccessful connections that have been attempted on this SAP since the SAP was created. An unsuccessful connection attempt is indicated by a SABME/DM exchange or a SABME/timeout.
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnect 1.3.6.1.4.1.9.10.8.1.2.3.1.27
This object reflects the total number of normal disconnections that have been performed on this SAP since the SAP was created. A normal disconnection is indicated by a successful DISC/UA exchange or merely a DISC sent or received.
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectFRMRSend 1.3.6.1.4.1.9.10.8.1.2.3.1.28
This object reflects the total number of abnormal disconnections (resulting from a FRMR being sent) that have been performed on this SAP since the SAP was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectFRMRRcv 1.3.6.1.4.1.9.10.8.1.2.3.1.29
This object reflects the total number of abnormal disconnections (resulting from a FRMR being received) that have been performed on this SAP since the SAP was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectTimer 1.3.6.1.4.1.9.10.8.1.2.3.1.30
This object reflects the total number of abnormal disconnections (resulting from a timer expiration) that have been performed on this SAP since the SAP was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsDMsInABM 1.3.6.1.4.1.9.10.8.1.2.3.1.31
This object reflects the total number of Disconnect Mode responses that have been received for CCs in ABM mode on this SAP since the SAP was created.
OBJECT-TYPE    
  Counter32  

llcSapStatsSABMEsInABM 1.3.6.1.4.1.9.10.8.1.2.3.1.32
This object reflects the total number of SABMEs that have been received for CCs in already in ABM mode on this SAP since the SAP was created.
OBJECT-TYPE    
  Counter32  

llcCcGroup 1.3.6.1.4.1.9.10.8.1.3
OBJECT IDENTIFIER    

llcCcAdminTable 1.3.6.1.4.1.9.10.8.1.3.1
This table contains objects that can be changed to manage an LLC connection component. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in llcCcAdminTable can be created either by an agent or a management station. The management station can create an entry in llcCcAdminTable by setting the appropriate value in llcCcAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the llcCcOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcAdminEntry

llcCcAdminEntry 1.3.6.1.4.1.9.10.8.1.3.1.1
A list of configured values for an LLC connection component.
OBJECT-TYPE    
  LlcCcAdminEntry  

llcCcRMac 1.3.6.1.4.1.9.10.8.1.3.1.1.1
This value is the remote MAC address for this Connection Component. This value is provided by the SNMP agent.
OBJECT-TYPE    
  MacAddress  

llcCcRSap 1.3.6.1.4.1.9.10.8.1.3.1.1.2
This value is the address of the remote SAP for this Connection Component. This value is provided by the SNMP agent.
OBJECT-TYPE    
  INTEGER 1..255  

llcCcAdminBounce 1.3.6.1.4.1.9.10.8.1.3.1.1.3
This object controls the resetting of the connection component. Setting this value to yes(2) results in the connection component being reset, llcCcOperState transitioning to a value of aDm(1), and the value of llcCcAdminBounce being set back to no(1).
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcCcAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.3.1.1.4
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
OBJECT-TYPE    
  Integer32  

llcCcAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.3.1.1.5
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
OBJECT-TYPE    
  INTEGER 0..127  

llcCcAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.3.1.1.6
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
OBJECT-TYPE    
  INTEGER 0..127  

llcCcAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.3.1.1.7
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxRetransmits, shall be used.
OBJECT-TYPE    
  Integer32  

llcCcAdminAckTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.8
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminAckTimer, shall be used.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.9
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminPbitTimer, shall be used.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminRejTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.10
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminRejTimer, shall be used.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminBusyTimer, shall be used.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminInactTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.12
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminInactTimer, shall be used. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.3.1.1.13
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminDelayAck, shall be used. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcAdminDelayAckTimer shall be ignored.
OBJECT-TYPE    
  Integer32  

llcCcAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.14
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object contains an administrative value which will be applied the next time this connection is established. This object is associated with the llcCcAdminDelayAckCount object and is only defined if that object has a value greater than one.
OBJECT-TYPE    
  TimeTicks  

llcCcAdminNw 1.3.6.1.4.1.9.10.8.1.3.1.1.15
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented.
OBJECT-TYPE    
  Integer32  

llcCcAdminRowStatus 1.3.6.1.4.1.9.10.8.1.3.1.1.16
This object is used by a management station to create or delete the row entry in llcCcAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the llcCcOperTable with llcCcOperState equal to 'aDM (1)'.
OBJECT-TYPE    
  RowStatus  

llcCcOperTable 1.3.6.1.4.1.9.10.8.1.3.2
This table contains current LLC link parameters. Many of these objects have corresponding objects in the llcCcAdminTable.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcOperEntry

llcCcOperEntry 1.3.6.1.4.1.9.10.8.1.3.2.1
A list of status and control values for an LLC connection component.
OBJECT-TYPE    
  LlcCcOperEntry  

llcCcOperState 1.3.6.1.4.1.9.10.8.1.3.2.1.1
This object describes the operational state of the LLC connection. If the connection component is disabled, llcCcOperState will transition to aDM(1). If the connection component is enabled, llcCcOperState will transition to normal(3).
OBJECT-TYPE    
  INTEGER aDM(1), setup(2), normal(3), busy(4), reject(5), await(6), awaitBusy(7), awaitReject(8), dConn(9), reset(10), error(11), conn(12), resetCheck(13), resetWait(14)  

llcCcOperMaxIPDUOctetsSend 1.3.6.1.4.1.9.10.8.1.3.2.1.2
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect that in this object. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
OBJECT-TYPE    
  Integer32  

llcCcOperMaxIPDUOctetsRcv 1.3.6.1.4.1.9.10.8.1.3.2.1.3
This object denotes the maximum I PDU size, in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5] The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
OBJECT-TYPE    
  Integer32  

llcCcOperMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.3.2.1.4
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect that in this object.
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.3.2.1.5
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5].
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxRetransmits 1.3.6.1.4.1.9.10.8.1.3.2.1.6
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5].
OBJECT-TYPE    
  Integer32  

llcCcOperAckTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.7
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times).
OBJECT-TYPE    
  TimeTicks  

llcCcOperPbitTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.8
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
OBJECT-TYPE    
  TimeTicks  

llcCcOperRejTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.9
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
OBJECT-TYPE    
  TimeTicks  

llcCcOperBusyTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.10
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive.
OBJECT-TYPE    
  TimeTicks  

llcCcOperInactTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
OBJECT-TYPE    
  TimeTicks  

llcCcOperDelayAckCount 1.3.6.1.4.1.9.10.8.1.3.2.1.12
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcOperDelayAckTimer should be ignored.
OBJECT-TYPE    
  Integer32  

llcCcOperDelayAckTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.13
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcCcOperDelayAckCount object and only has meaning if that object has a value greater than one.
OBJECT-TYPE    
  TimeTicks  

llcCcOperNw 1.3.6.1.4.1.9.10.8.1.3.2.1.14
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
OBJECT-TYPE    
  Integer32  

llcCcOperWw 1.3.6.1.4.1.9.10.8.1.3.2.1.15
Maximum number of sequentially numbered IPDUs that the connection component may have outstanding (unacknowledged) at any given time. Ww is initialized to the value of llcCcOperMaxUnackedIPDUsSend when the link is established. When the dynamic window algorithm is invoked, Ww varies from 1 up to llcCcOperMaxUnackedIPDUsSend. Each time the llcCcOperWw value is decreased, the reason is recorded in llcCcOperLastWwCause, and llcCcStatWwCount is incremented by 1. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperCreateTime 1.3.6.1.4.1.9.10.8.1.3.2.1.16
This object describes the value of sysUpTime when this connection was created.
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastModifyTime 1.3.6.1.4.1.9.10.8.1.3.2.1.17
This object describes the value of sysUpTime the last time this connection component was modified. If the connection has not been modified, then this value shall be zero.
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastFailTime 1.3.6.1.4.1.9.10.8.1.3.2.1.18
This object describes the value of sysUpTime when this LLC connection component last failed. If the connection component has not failed, then this value shall be zero.
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastFailCause 1.3.6.1.4.1.9.10.8.1.3.2.1.19
This enumerated object reflects the cause of the last failure of this LLC connection component. If the connection component has not failed, then this object will have a value of undefined(1).
OBJECT-TYPE    
  INTEGER undefined(1), rxFRMR(2), txFRMR(3), discReceived(4), discSent(5), retriesExpired(6), forcedShutdown(7)  

llcCcOperLastFailFRMRInfo 1.3.6.1.4.1.9.10.8.1.3.2.1.20
This object reflects the information field of the FRMR frame if the last failure for this LLC connection component was as a result of an invalid frame. Otherwise, this field has no meaning.
OBJECT-TYPE    
  OCTET STRING SIZE(3)  

llcCcOperLastWwCause 1.3.6.1.4.1.9.10.8.1.3.2.1.21
This object indicates the reason that the llcCcOperWw was reduced the last time this occurred.
OBJECT-TYPE    
  INTEGER neverInvoked(1), lostData(2), macLayerCongestion(3), other(4)  

llcCcStatsTable 1.3.6.1.4.1.9.10.8.1.3.3
Each entry in this table contains statistics for a specific LLC connection component.
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcStatsEntry

llcCcStatsEntry 1.3.6.1.4.1.9.10.8.1.3.3.1
A list of statistics for an LLC connection component.
OBJECT-TYPE    
  LlcCcStatsEntry  

llcCcStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.3.3.1.1
This object reflects the total number of times that the local connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsRemoteBusies 1.3.6.1.4.1.9.10.8.1.3.3.1.2
This object reflects the total number of times that the adjacent (i.e. remote) connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesIn 1.3.6.1.4.1.9.10.8.1.3.3.1.3
This object reflects the total number of I-Frames that have been received by the connection component. This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesOut 1.3.6.1.4.1.9.10.8.1.3.3.1.4
This object reflects the total number of I-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsIn 1.3.6.1.4.1.9.10.8.1.3.3.1.5
This object reflects the total octets received from the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.6
This object reflects the total octets transmitted to the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsSFramesIn 1.3.6.1.4.1.9.10.8.1.3.3.1.7
This object reflects the total number of S-Frames that have been received by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
OBJECT-TYPE    
  Counter32  

llcCcStatsSFramesOut 1.3.6.1.4.1.9.10.8.1.3.3.1.8
This object reflects the total number of S-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
OBJECT-TYPE    
  Counter32  

llcCcStatsRetransmitsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.9
This object reflects the total number of I-Frames retransmitted the local connection component. This object is initialized to zero when the connection component is created.
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsIn 1.3.6.1.4.1.9.10.8.1.3.3.1.10
This object reflects the total REJ frames received from an adjacent LLC connection component since connection component startup.
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.11
This object reflects the total REJ frames transmitted to an adjacent LLC connection component since connection component startup.
OBJECT-TYPE    
  Counter32  

llcCcStatsWwCount 1.3.6.1.4.1.9.10.8.1.3.3.1.12
This object reflects the total number of times, since connection component startup, that the dynamic window algorithm has been invoked to reduce the value of Ww. At connection component startupm this object must be initialized to zero. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
OBJECT-TYPE    
  Counter32  

snaLlcMIBNotificationPrefix 1.3.6.1.4.1.9.10.8.2
OBJECT IDENTIFIER    

snaLlcMIBNotifications 1.3.6.1.4.1.9.10.8.2.0
OBJECT IDENTIFIER    

llcCcStatusChange 1.3.6.1.4.1.9.10.8.2.0.1
This trap indicates that the state of an LLC connection component has transitioned to normal(3) or aDM(1).
NOTIFICATION-TYPE    
  llcCcOperState  
  llcCcOperLastFailTime  
  llcCcOperLastFailCause  
  llcCcOperLastFailFRMRInfo  

snaLlcMIBConformance 1.3.6.1.4.1.9.10.8.3
OBJECT IDENTIFIER    

snaLlcMIBCompliances 1.3.6.1.4.1.9.10.8.3.1
OBJECT IDENTIFIER    

llcCoreCompliance 1.3.6.1.4.1.9.10.8.3.1.1
The core compliance statement for all LLC nodes.
MODULE-COMPLIANCE    

snaLlcMIBGroups 1.3.6.1.4.1.9.10.8.3.2
OBJECT IDENTIFIER    

llcCorePortGroup 1.3.6.1.4.1.9.10.8.3.2.1
The llcCorePortGroup defines objects which are common to the LLC Port of all compliant connections.
OBJECT-GROUP    

llcCoreSapGroup 1.3.6.1.4.1.9.10.8.3.2.2
The llcCoreSapGroup defines objects which are common to the LLC SAP of all compliant connections.
OBJECT-GROUP    

llcCoreCcGroup 1.3.6.1.4.1.9.10.8.3.2.3
The llcCoreCcGroup defines objects which are common to the LLC CC of all compliant connections.
OBJECT-GROUP    

Defined Objects

LlcPortAdminEntry  
SEQUENCE    
  Integer32 as llcPortVirtualIndex  
  DisplayString as llcPortAdminName  
  Gauge32 as llcPortAdminMaxSaps  
  Gauge32 as llcPortAdminMaxCcs  
  Integer32 as llcPortAdminMaxPDUOctets  
  INTEGER as llcPortAdminMaxUnackedIPDUsSend  
  INTEGER as llcPortAdminMaxUnackedIPDUsRcv  
  Integer32 as llcPortAdminMaxRetransmits  
  TimeTicks as llcPortAdminAckTimer  
  TimeTicks as llcPortAdminPbitTimer  
  TimeTicks as llcPortAdminRejTimer  
  TimeTicks as llcPortAdminBusyTimer  
  TimeTicks as llcPortAdminInactTimer  
  Integer32 as llcPortAdminDelayAckCount  
  TimeTicks as llcPortAdminDelayAckTimer  
  Integer32 as llcPortAdminNw  

LlcPortOperEntry  
SEQUENCE    
  MacAddress as llcPortOperMacAddress  
  Gauge32 as llcPortOperNumSaps  
  Gauge32 as llcPortOperHiWaterNumSaps  
  INTEGER as llcPortOperSimRim  
  TimeStamp as llcPortOperLastModifyTime  

LlcPortStatsEntry  
SEQUENCE    
  Counter32 as llcPortStatsPDUsIn  
  Counter32 as llcPortStatsPDUsOut  
  Counter32 as llcPortStatsOctetsIn  
  Counter32 as llcPortStatsOctetsOut  
  Counter32 as llcPortStatsTESTCommandsIn  
  Counter32 as llcPortStatsTESTResponsesOut  
  Counter32 as llcPortStatsLocalBusies  
  Counter32 as llcPortStatsUnknownSaps  

LlcSapAdminEntry  
SEQUENCE    
  INTEGER as llcSapNumber  
  Integer32 as llcSapAdminMaxPDUOctets  
  INTEGER as llcSapAdminMaxUnackedIPDUsSend  
  INTEGER as llcSapAdminMaxUnackedIPDUsRcv  
  Integer32 as llcSapAdminMaxRetransmits  
  TimeTicks as llcSapAdminAckTimer  
  TimeTicks as llcSapAdminPbitTimer  
  TimeTicks as llcSapAdminRejTimer  
  TimeTicks as llcSapAdminBusyTimer  
  TimeTicks as llcSapAdminInactTimer  
  Integer32 as llcSapAdminDelayAckCount  
  TimeTicks as llcSapAdminDelayAckTimer  
  Integer32 as llcSapAdminNw  

LlcSapOperEntry  
SEQUENCE    
  INTEGER as llcSapOperStatus  
  Integer32 as llcSapOperNumCcs  
  Gauge32 as llcSapOperHiWaterNumCcs  
  INTEGER as llcSapOperLlc2Support  

LlcSapStatsEntry  
SEQUENCE    
  Counter32 as llcSapStatsLocalBusies  
  Counter32 as llcSapStatsRemoteBusies  
  Counter32 as llcSapStatsIFramesIn  
  Counter32 as llcSapStatsIFramesOut  
  Counter32 as llcSapStatsIOctetsIn  
  Counter32 as llcSapStatsIOctetsOut  
  Counter32 as llcSapStatsSFramesIn  
  Counter32 as llcSapStatsSFramesOut  
  Counter32 as llcSapStatsRetransmitsOut  
  Counter32 as llcSapStatsREJsIn  
  Counter32 as llcSapStatsREJsOut  
  Counter32 as llcSapStatsWwCount  
  Counter32 as llcSapStatsTESTCommandsIn  
  Counter32 as llcSapStatsTESTCommandsOut  
  Counter32 as llcSapStatsTESTResponsesIn  
  Counter32 as llcSapStatsTESTResponsesOut  
  Counter32 as llcSapStatsXIDCommandsIn  
  Counter32 as llcSapStatsXIDCommandsOut  
  Counter32 as llcSapStatsXIDResponsesIn  
  Counter32 as llcSapStatsXIDResponsesOut  
  Counter32 as llcSapStatsUIFramesIn  
  Counter32 as llcSapStatsUIFramesOut  
  Counter32 as llcSapStatsUIOctetsIn  
  Counter32 as llcSapStatsUIOctetsOut  
  Counter32 as llcSapStatsConnectOk  
  Counter32 as llcSapStatsConnectFail  
  Counter32 as llcSapStatsDisconnect  
  Counter32 as llcSapStatsDisconnectFRMRSend  
  Counter32 as llcSapStatsDisconnectFRMRRcv  
  Counter32 as llcSapStatsDisconnectTimer  
  Counter32 as llcSapStatsDMsInABM  
  Counter32 as llcSapStatsSABMEsInABM  

LlcCcAdminEntry  
SEQUENCE    
  MacAddress as llcCcRMac  
  INTEGER as llcCcRSap  
  INTEGER as llcCcAdminBounce  
  Integer32 as llcCcAdminMaxPDUOctets  
  INTEGER as llcCcAdminMaxUnackedIPDUsSend  
  INTEGER as llcCcAdminMaxUnackedIPDUsRcv  
  Integer32 as llcCcAdminMaxRetransmits  
  TimeTicks as llcCcAdminAckTimer  
  TimeTicks as llcCcAdminPbitTimer  
  TimeTicks as llcCcAdminRejTimer  
  TimeTicks as llcCcAdminBusyTimer  
  TimeTicks as llcCcAdminInactTimer  
  Integer32 as llcCcAdminDelayAckCount  
  TimeTicks as llcCcAdminDelayAckTimer  
  Integer32 as llcCcAdminNw  
  RowStatus as llcCcAdminRowStatus  

LlcCcOperEntry  
SEQUENCE    
  INTEGER as llcCcOperState  
  Integer32 as llcCcOperMaxIPDUOctetsSend  
  Integer32 as llcCcOperMaxIPDUOctetsRcv  
  INTEGER as llcCcOperMaxUnackedIPDUsSend  
  INTEGER as llcCcOperMaxUnackedIPDUsRcv  
  Integer32 as llcCcOperMaxRetransmits  
  TimeTicks as llcCcOperAckTimer  
  TimeTicks as llcCcOperPbitTimer  
  TimeTicks as llcCcOperRejTimer  
  TimeTicks as llcCcOperBusyTimer  
  TimeTicks as llcCcOperInactTimer  
  Integer32 as llcCcOperDelayAckCount  
  TimeTicks as llcCcOperDelayAckTimer  
  Integer32 as llcCcOperNw  
  INTEGER as llcCcOperWw  
  TimeStamp as llcCcOperCreateTime  
  TimeStamp as llcCcOperLastModifyTime  
  TimeStamp as llcCcOperLastFailTime  
  INTEGER as llcCcOperLastFailCause  
  OCTET STRING as llcCcOperLastFailFRMRInfo  
  INTEGER as llcCcOperLastWwCause  

LlcCcStatsEntry  
SEQUENCE    
  Counter32 as llcCcStatsLocalBusies  
  Counter32 as llcCcStatsRemoteBusies  
  Counter32 as llcCcStatsIFramesIn  
  Counter32 as llcCcStatsIFramesOut  
  Counter32 as llcCcStatsIOctetsIn  
  Counter32 as llcCcStatsIOctetsOut  
  Counter32 as llcCcStatsSFramesIn  
  Counter32 as llcCcStatsSFramesOut  
  Counter32 as llcCcStatsRetransmitsOut  
  Counter32 as llcCcStatsREJsIn  
  Counter32 as llcCcStatsREJsOut  
  Counter32 as llcCcStatsWwCount