CISCO-ST-TC
File:
CISCO-ST-TC.mib (18244 bytes)
Imported modules
Imported symbols
Defined Objects
| storageTextualConventions |
1.3.6.1.4.1.9.12.4 |
| This module defines textual conventions used in Storage Area Network technology specific mibs. |
| MODULE-IDENTITY |
|
|
|
Defined Objects
| VsanIndex |
|
| The VSAN id of a VSAN which uniquely identifies a VSAN within a fabric. VSAN id is 12-bit wide; so theoretically, 4096 VSANs can be defined in a fabric and this device can be part of. However, VSAN numbers 0 , 4094 and 4095 are reserved. |
| TEXTUAL-CONVENTION |
|
|
|
| |
Integer32 |
1..4094 |
|
| DomainId |
|
| The Domain Id of the switch. This is assigned dynamically if the Domain Manager is enabled on the switch or could be configured statically by the user. |
| TEXTUAL-CONVENTION |
|
|
|
| |
Integer32 |
1..239 |
|
| DomainIdOrZero |
|
| The Textual convention is an extension to textual convetion 'DomainId'. It includes the value '0'in addition the range 1-239. Value '0' indicates that Domain Id has been neither configured nor assigned. |
| TEXTUAL-CONVENTION |
|
|
|
| |
Integer32 |
0..239 |
|
| FcAddressId |
|
| Represents Fibre Channel Address ID, a 24-bit value unique within the address space of a Fabric. |
| TEXTUAL-CONVENTION |
|
|
|
| |
OCTET STRING |
SIZE(3) |
|
| FcNameId |
|
| Represents the World Wide Name (WWN) associated with a Fibre Channel (FC) entity. A WWN is a 64 bit address to uniquely identify each entity within a Fibre Channel fabric. |
| TEXTUAL-CONVENTION |
|
|
|
| |
OCTET STRING |
SIZE(8) |
|
| FcNameIdOrZero |
|
| The World Wide Name (WWN) associated with a Fibre Channel (FC) entity. WWNs were initially defined as 64-bits in length. The latest definition (for future use) is 128-bits long. The zero-length string value is used in circumstances where the WWN is unassigned/unknown. |
| TEXTUAL-CONVENTION |
|
|
|
| |
OCTET STRING |
SIZE(0 | 8 | 16) |
|
| FcClassOfServices |
|
| Represents the class of service capability of an NxPort or FxPort. |
| TEXTUAL-CONVENTION |
|
|
|
| |
BITS |
classF(0), class1(1), class2(2), class3(3), class4(4), class5(5), class6(6) |
|
| FcPortTypes |
|
| Represents fibre channel port types: auto (1) - Mode is determined by port initialization scheme. fPort (2) - Fibre channel fabric port. flPort (3) - Fibre channel arbitrated loop port. ePort (4) - Fabric Expansion port. bPort (5) - Bridging port. fxPort (6) - This port can only be f_port or fl_port. sdPort (7) - SPAN destination port. SD_ports transmit traffic copied from one or more source ports for monitoring purposes. tlPort (8) - Translation loop port. nPort (9) - Fibre channel N port. nlPort (10) - Fibre channel NL port. nxPort (11) - This port can only be n_port or nl_port. -- read only port types. tePort (12) - Trunking e_port. Note: A port which is administratively set to 'ePort', will operationally have type 'tePort' if fcIfOperTrunkMode has the value 'trunk'. fvPort (13) - Virtual Port. portOperDown (14) - port operationally down If a port is operationally down, the port mode is unknown. In such cases the operational port mode is shown as 'portOperDown'. stPort (15) - SPAN Tunnel destination port. npPort (16) - N Proxy port mode applicable only to N-port Virtualizer (NPV) tfPort (17) - Trunking fibre channel fabric port. tnpPort (18) - Trunking N Proxy port mode applicable only to N-port Virtualizer (NPV). |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
auto(1), fPort(2), flPort(3), ePort(4), bPort(5), fxPort(6), sdPort(7), tlPort(8), nPort(9), nlPort(10), nxPort(11), tePort(12), fvPort(13), portOperDown(14), stPort(15), npPort(16), tfPort(17), tnpPort(18) |
|
| FcPortTxTypes |
|
| Represents port transciever technology types. unknown (1) - unknown longWaveLaser (2) - 1550nm laser shortWaveLaser (3) - 850nm laser longWaveLaserCostReduced (4) - 1310nm laser electrical (5) - electrical tenGigBaseSr (6) - 10GBASE-SR 850nm laser tenGigBaseLr (7) - 10GBASE-LR 1310nm laser tenGigBaseEr (8) - 10GBASE-ER 1550nm laser tenGigBaseLx4 (9) - 10GBASE-LX4 WWDM 1300nm laser tenGigBaseSw (10) - 850nm laser tenGigBaseLw (11) - 1310nm laser tenGigBaseEw (12) - 1550nm laser . |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
unknown(1), longWaveLaser(2), shortWaveLaser(3), longWaveLaserCostReduced(4), electrical(5), tenGigBaseSr(6), tenGigBaseLr(7), tenGigBaseEr(8), tenGigBaseLx4(9), tenGigBaseSw(10), tenGigBaseLw(11), tenGigBaseEw(12) |
|
| FcPortModuleTypes |
|
| Represents module type of the port connector. This object refers to the hardware implementation of the port. The enums are defined as per FC-GS-4 standard. unknown (1) - unknown other (2) - other gbic (3) - gbic (gigabit interface card) embedded (4) - gbic is part of the line card and is unremovable glm (5) - if its a gigabit link module (GLM). A GLM has a different form factor than GBIC. GLM is not supported by our switch. gbicWithSerialID (6) - If GBIC serial id can be read gbicWithoutSerialID (7) - If GBIC serial id cannot be read sfpWithSerialID (8) - If small form factor (SFP) pluggable GBICs serial id can be read sfpWithoutSerialID (9) - If small form factor (SFP) pluggable GBICs serial id cannot be read The following enums are module types for 10 gigabit small form factor pluggable sfp port connectors. xfp (10) - xfp x2Short (11) - x2 short x2Medium (12) - x2 medium x2Tall (13) - x2 tall xpakShort (14) - xpak short xpakMedium (15) - xpak medium xpakTall (16) - xpak tall xenpak (17) - xenpak sfpDwdm (18) - DWDM SFP type qsfp (19) - Quad small form-factor (QSFP) pluggable type x2Dwdm (20) - x2 DWDM . |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
unknown(1), other(2), gbic(3), embedded(4), glm(5), gbicWithSerialID(6), gbicWithoutSerialID(7), sfpWithSerialID(8), sfpWithoutSerialID(9), xfp(10), x2Short(11), x2Medium(12), x2Tall(13), xpakShort(14), xpakMedium(15), xpakTall(16), xenpak(17), sfpDwdm(18), qsfp(19), x2Dwdm(20) |
|
| FcIfSpeed |
|
| Represents the speed of a fibre channel port. Following are the meanings of the enumerated values: auto (1) - Negotiate to determine the speed automatically. oneG (2) - 1Gbit twoG (3) - 2Gbit fourG (4) - 4Gbit autoMaxTwoG (5) - Negotiate to determine the speed automatically upto a maximum of 2Gbit. |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
auto(1), oneG(2), twoG(3), fourG(4), autoMaxTwoG(5) |
|
| PortMemberList |
|
| A list of ifIndex's of the ports that are members of this list. The value of this object is a concatenation of zero or more 4-octet strings, where each 4-octet string contains a 32-bit ifIndex value in network byte order. A zero length string value means this list has no members. |
| TEXTUAL-CONVENTION |
|
|
|
| |
OCTET STRING |
SIZE(0..64) |
|
| FcAddress |
|
| Represents either the Fibre Channel Address ID or the World Wide Name associated with a Fibre Channel (FC) Entity. |
| TEXTUAL-CONVENTION |
|
|
|
| |
OCTET STRING |
SIZE(3 | 8) |
|
| FcAddressType |
|
| Denotes if a Fibre Channel Address is a World Wide Name (WWN) or a Fibre Channel Address ID (FCID). wwn(1) - address is WWN. fcid(2) - address is FCID. |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
wwn(1), fcid(2) |
|
| InterfaceOperMode |
|
| Represents the operational mode of an interface auto (1) - Mode is determined by port initialization scheme. fPort (2) - Fibre channel fabric port. flPort (3) - Fibre channel arbitrated loop port. ePort (4) - Fabric Expansion port. bPort (5) - Bridging port. fxPort (6) - This port can only be f_port or fl_port. sdPort (7) - SPAN destination port. SD_ports transmit traffic copied from one or more source ports for monitoring purposes. tlPort (8) - Translation loop port. nPort (9) - Fibre channel N port. nlPort (10) - Fibre channel NL port. nxPort (11) - This port can only be n_port or nl_port. -- read only port types. tePort (12) - Trunking e_port. Note: A port which is administratively set to 'ePort', will operationally have type 'tePort' if fcIfOperTrunkMode has the value 'trunk'. fvPort (13) - Virtual Port. portOperDown (14) - port operationally down If a port is operationally down, the port mode is unknown. In such cases the operational port mode is shown as 'portOperDown'. stPort (15) - SPAN Tunnel destination port. mgmtPort(16) - Mgmt Port. ipsPort(17) - Ethernet Port. evPort(18) - FCIP tunnels on Ethernet ports. npPort (19) - N Proxy port mode applicable only to N-port Virtualizer (NPV). tfPort (20) - Trunking fibre channel fabric port. tnpPort (21) - Trunking N Proxy port mode applicable only to N-port Virtualizer (NPV). |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
auto(1), fPort(2), flPort(3), ePort(4), bPort(5), fxPort(6), sdPort(7), tlPort(8), nPort(9), nlPort(10), nxPort(11), tePort(12), fvPort(13), portOperDown(14), stPort(15), mgmtPort(16), ipsPort(17), evPort(18), npPort(19), tfPort(20), tnpPort(21) |
|
| FcIfServiceStateType |
|
| Represents the service state of a Fibre Channel interface. Following are the meanings of the enumerated values: inService (1) - interface is in service and is allowed to become operational. outOfService (2) - interface is removed from service and is not allowed to become operational. |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
inService(1), outOfService(2) |
|
| FcIfSfpDiagLevelType |
|
| Represents the severity level of the SFP diagnostic information of an interface for temperature, voltage, current, optical transmit and receive power. |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
unknown(1), normal(2), lowWarning(3), lowAlarm(4), highWarning(5), highAlarm(6) |
|