| RFC-1215 | RFC1065-SMI | RFC-1212 |
| RFC1213-MIB | CNT2-MIB |
| TRAP-TYPE | enterprises | Counter |
| OBJECT-TYPE | DisplayString | cnt2Subagent |
| cnt2Sm | 1.3.6.1.4.1.333.2.4.1 | ||
| OBJECT IDENTIFIER | |||
| cnt2SmHw | 1.3.6.1.4.1.333.2.4.1.1 | ||
| OBJECT IDENTIFIER | |||
| cnt2smEmergencyMsg | 1.3.6.1.4.1.333.2.4.1.1 | ||
| An emergency level trap (0) signifies that an event has occured which has rendered the system unusable. All modules and interfaces will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2SmHwTemperatureF | 1.3.6.1.4.1.333.2.4.1.1.1 | ||
| The temperature in Farenheit of the node in the range (0..255). If/when the temperature transitions from below 113 degrees to above 113 degrees, a advisory trap will be sent. If/when the temperature transitions from below 131 degrees to above 131 degrees, a repair trap will be sent. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwTapeDriveState | 1.3.6.1.4.1.333.2.4.1.1.2 | ||
| The state of the DAT tape drive. | |||
| OBJECT-TYPE | |||
| INTEGER | not-present(1), ok(2), failed(3) | ||
| cnt2SmHwCdRomDriveState | 1.3.6.1.4.1.333.2.4.1.1.3 | ||
| The state of the CD drive. | |||
| OBJECT-TYPE | |||
| INTEGER | not-present(1), ok(2), failed(3) | ||
| cnt2SmHwTapeMounted | 1.3.6.1.4.1.333.2.4.1.1.4 | ||
| Indicates whether the DAT tape drive contains a tape. | |||
| OBJECT-TYPE | |||
| INTEGER | not-applicable(1), empty(2), mounted(3) | ||
| cnt2SmHwCdRomMounted | 1.3.6.1.4.1.333.2.4.1.1.5 | ||
| Indicates whether the CD drive contains a CD. | |||
| OBJECT-TYPE | |||
| INTEGER | not-applicable(1), empty(2), mounted(3) | ||
| cnt2SmHwServiceLed | 1.3.6.1.4.1.333.2.4.1.1.6 | ||
| The state of the service LED. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| cnt2SmHwIplSwitch | 1.3.6.1.4.1.333.2.4.1.1.7 | ||
| The state of the IPL switch. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| cnt2SmHwAdapterTable | 1.3.6.1.4.1.333.2.4.1.1.8 | ||
| List of adapters in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmHwAdapterEntry | |||
| cnt2SmHwAdapterEntry | 1.3.6.1.4.1.333.2.4.1.1.8.1 | ||
| A adapter entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmHwAdapterEntry | |||
| cnt2SmHwAdapterIndex | 1.3.6.1.4.1.333.2.4.1.1.8.1.1 | ||
| The relative index of this adapter entry within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwAdapterOperState | 1.3.6.1.4.1.333.2.4.1.1.8.1.2 | ||
| The state of the adapter in this slot. | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), not-ok(2) | ||
| cnt2SmHwAdapterAdminState | 1.3.6.1.4.1.333.2.4.1.1.8.1.3 | ||
| The state of the adapter in this slot. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2), reset(3) | ||
| cnt2SmHwCardTable | 1.3.6.1.4.1.333.2.4.1.1.9 | ||
| List of adapters in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmHwCardEntry | |||
| cnt2SmHwCardEntry | 1.3.6.1.4.1.333.2.4.1.1.9.1 | ||
| A adapter entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmHwCardEntry | |||
| cnt2SmCardAdapterIndex | 1.3.6.1.4.1.333.2.4.1.1.9.1.1 | ||
| The relative index of this adapter entry within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwCardIndex | 1.3.6.1.4.1.333.2.4.1.1.9.1.2 | ||
| The relative index of this adapter entry within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwCardOperState | 1.3.6.1.4.1.333.2.4.1.1.9.1.3 | ||
| The state of the adapter in this slot. | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), not-ok(2) | ||
| cnt2SmHwCardAdminState | 1.3.6.1.4.1.333.2.4.1.1.9.1.4 | ||
| The state of the adapter in this slot. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2), reset(3) | ||
| cnt2SmHwPowerSupplyTable | 1.3.6.1.4.1.333.2.4.1.1.10 | ||
| List of power supplies in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmHwPowerSupplyEntry | |||
| cnt2SmHwPowerSupplyEntry | 1.3.6.1.4.1.333.2.4.1.1.10.1 | ||
| A power supply entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmHwPowerSupplyEntry | |||
| cnt2SmHwPowerSupplyIndex | 1.3.6.1.4.1.333.2.4.1.1.10.1.1 | ||
| The relative index of this power supply entry within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwPowerSupplyACState | 1.3.6.1.4.1.333.2.4.1.1.10.1.2 | ||
| The AC state of this power supply. | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), not-ok(2), absent(3) | ||
| cnt2SmHwPowerSupplyDCState | 1.3.6.1.4.1.333.2.4.1.1.10.1.3 | ||
| The DC state of this power supply. | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), not-ok(2), absent(3) | ||
| cnt2SmHwFanTable | 1.3.6.1.4.1.333.2.4.1.1.11 | ||
| List of power supplies in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmHwFanEntry | |||
| cnt2SmHwFanEntry | 1.3.6.1.4.1.333.2.4.1.1.11.1 | ||
| A fan entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmHwFanEntry | |||
| cnt2SmHwFanIndex | 1.3.6.1.4.1.333.2.4.1.1.11.1.1 | ||
| The relative index of this fan entry within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmHwFanState | 1.3.6.1.4.1.333.2.4.1.1.11.1.2 | ||
| The state of this fan. | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), not-ok(2) | ||
| cnt2SmSw | 1.3.6.1.4.1.333.2.4.1.2 | ||
| OBJECT IDENTIFIER | |||
| cnt2smAlertMsg | 1.3.6.1.4.1.333.2.4.1.2 | ||
| An Alert level trap (1) signifies that an event has occured which requires that immediate action be taken. The module will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2SmNumModules | 1.3.6.1.4.1.333.2.4.1.2.1 | ||
| The number of software modules making up the set referred to as the Service Monitor. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmSwTable | 1.3.6.1.4.1.333.2.4.1.2.2 | ||
| List of entries in the service monitor software module table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmSwEntry | |||
| cnt2SmSwEntry | 1.3.6.1.4.1.333.2.4.1.2.2.1 | ||
| A service monitor software module entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmSwEntry | |||
| cnt2SmSwIndex | 1.3.6.1.4.1.333.2.4.1.2.2.1.1 | ||
| The relative index of this software module entry within the service monitor. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmSwName | 1.3.6.1.4.1.333.2.4.1.2.2.1.2 | ||
| The name of the service monitor module. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmSwFunction | 1.3.6.1.4.1.333.2.4.1.2.2.1.3 | ||
| The primary function performed by this software module. | |||
| OBJECT-TYPE | |||
| INTEGER | loading(1), dumping(2), configuration(3), messages(4), hw-monitoring(5), tracing(6), snmp-master-agent(7), console(8), utilities(9) | ||
| cnt2SmSwMajorVersion | 1.3.6.1.4.1.333.2.4.1.2.2.1.4 | ||
| The major version number of this software module. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmSwMinorVersion | 1.3.6.1.4.1.333.2.4.1.2.2.1.5 | ||
| The minor version number of this software module. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmSwSlot | 1.3.6.1.4.1.333.2.4.1.2.3 | ||
| The slot number of the active Service Monitor. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmSwAccess | 1.3.6.1.4.1.333.2.4.1.2.4 | ||
| The access permissions of the active Service Monitor. | |||
| OBJECT-TYPE | |||
| INTEGER | read-write-access(1), read-only-access(2) | ||
| cnt2SmMsg | 1.3.6.1.4.1.333.2.4.1.3 | ||
| OBJECT IDENTIFIER | |||
| cnt2smCriticalMsg | 1.3.6.1.4.1.333.2.4.1.3 | ||
| A Critical level trap (1) signifies that an event has occured for which action should be taken. The module will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2SmNumMsgs | 1.3.6.1.4.1.333.2.4.1.3.1 | ||
| The number of messages in the system message file that have been entered by all modules within the node. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMsgTable | 1.3.6.1.4.1.333.2.4.1.3.2 | ||
| List of entries in the service monitor message file. This file contains any messages that has been entered by any software residing in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmMsgEntry | |||
| cnt2SmMsgEntry | 1.3.6.1.4.1.333.2.4.1.3.2.1 | ||
| A message file entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmMsgEntry | |||
| cnt2SmMsgIndex | 1.3.6.1.4.1.333.2.4.1.3.2.1.1 | ||
| The relative index of this message entry within the message file. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMsgSeverity | 1.3.6.1.4.1.333.2.4.1.3.2.1.2 | ||
| The severity of this message. | |||
| OBJECT-TYPE | |||
| INTEGER | emergency(1), alert(2), criticial(3), error(4), warning(5), notice(6), information(7), debug(8) | ||
| cnt2SmMsgProcessName | 1.3.6.1.4.1.333.2.4.1.3.2.1.3 | ||
| The name of the process that sent this message to the message server. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmMsgNumber | 1.3.6.1.4.1.333.2.4.1.3.2.1.4 | ||
| The number of this message. Each module numbers its message type as another way of describing it. This message can then be cross-referenced in the CNT system messages reference manual. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMsgSlotNumber | 1.3.6.1.4.1.333.2.4.1.3.2.1.5 | ||
| The slot number of the module that sent this message to the message server. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmMsgDateTime | 1.3.6.1.4.1.333.2.4.1.3.2.1.6 | ||
| The date and time that this message was sent to the message server. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmMsgErrorNumber | 1.3.6.1.4.1.333.2.4.1.3.2.1.7 | ||
| The number of the Error message which caused us to generate this error message. Each module numbers its message errors as another way of describing it. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMsgContent | 1.3.6.1.4.1.333.2.4.1.3.2.1.8 | ||
| The textual detail of the message sent to the message server. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmMessage | 1.3.6.1.4.1.333.2.4.1.4 | ||
| OBJECT IDENTIFIER | |||
| cnt2smErrorMsg | 1.3.6.1.4.1.333.2.4.1.4 | ||
| An Error level trap (3) signifies that an event has occured that has resulted in errors. The module will probably be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2SmMsgTableSize | 1.3.6.1.4.1.333.2.4.1.4.1 | ||
| The number of messages that are available through SNMP access. This message table is limited to the most recent number messages specified by this object. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMessageTable | 1.3.6.1.4.1.333.2.4.1.4.2 | ||
| List of entries in the service monitor message file. This file contains any messages that has been entered by any software residing in the node. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cnt2SmMessageEntry | |||
| cnt2SmMessageEntry | 1.3.6.1.4.1.333.2.4.1.4.2.1 | ||
| A message file entry. | |||
| OBJECT-TYPE | |||
| Cnt2SmMessageEntry | |||
| cnt2SmMessageText | 1.3.6.1.4.1.333.2.4.1.4.2.1.1 | ||
| The textual detail of the message sent to the message server. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cnt2SmMessageIndex | 1.3.6.1.4.1.333.2.4.1.4.2.1.2 | ||
| The textual index of the message sent to the message server. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cnt2SmMsgToTrapFilter | 1.3.6.1.4.1.333.2.4.1.4.3 | ||
| Messages in cnt2SmMessageTable can be sent as traps to selected destinations. However, the messages are filtered by severity before they are forwarded as traps. This object determines which of the messages are filtered. All messages with severity equal and lower in value than the value of this object are forwarded as traps. Severity levels range from 0 (lowest) to 7 (highest). A value of 0 would cause all messages to be forwarded as traps. | |||
| OBJECT-TYPE | |||
| INTEGER | emergency(1), alert(2), criticial(3), error(4), warning(5), notice(6), information(7), none(8) | ||
| cnt2smWarningMsg | 1.3.6.1.4.1.333.2.4.1.5 | ||
| A Warning level trap (4) signifies that an event has occured that may affect the module. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2smNoticeMsg | 1.3.6.1.4.1.333.2.4.1.6 | ||
| A Notice level trap (1) signifies that an event has occured that is normal but that has significance. The module should be unaffected | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2smInfoMsg | 1.3.6.1.4.1.333.2.4.1.7 | ||
| An Informaiton level trap (6) signifies that an event has occured that informational in severity and that the module will not be affected by this error. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2smDebugMsg | 1.3.6.1.4.1.333.2.4.1.8 | ||
| A Debug level trap (7) signifies that an event has occured at a debug level that is informational. The module will not be affected by this error. | |||
| TRAP-TYPE | |||
| cnt2SmMsgProcessName | |||
| cnt2SmMsgNumber | |||
| cnt2SmMsgSlotNumber | |||
| cnt2SmMsgDateTime | |||
| cnt2SmMsgErrorNumber | |||
| cnt2SmMsgContent | |||
| cnt2smEmergencyTrap | 1.3.6.1.4.1.333.2.4.1.9 | ||
| An emergency level trap signifies that an event has occured which has rendered the system unusable. All modules and interfaces will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smAlertTrap | 1.3.6.1.4.1.333.2.4.1.10 | ||
| An Alert level trap signifies that an event has occured which requires that immediate action be taken. The module will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smCriticalTrap | 1.3.6.1.4.1.333.2.4.1.11 | ||
| A Critical level trap signifies that an event has occured for which action should be taken. The module will be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smErrorTrap | 1.3.6.1.4.1.333.2.4.1.12 | ||
| An Error level trap signifies that an event has occured that has resulted in errors. The module will probably be affected. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smWarningTrap | 1.3.6.1.4.1.333.2.4.1.13 | ||
| A Warning level trap signifies that an event has occured that may affect the module. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smNoticeTrap | 1.3.6.1.4.1.333.2.4.1.14 | ||
| A Notice level trap signifies that an event has occured that is normal but that has significance. The module should be unaffected | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| cnt2smInfoTrap | 1.3.6.1.4.1.333.2.4.1.15 | ||
| An Informaiton level trap signifies that an event has occured that informational in severity and that the module will not be affected by this error. | |||
| TRAP-TYPE | |||
| cnt2SmMessageText | |||
| Cnt2SmHwAdapterEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmHwAdapterIndex | |||
| INTEGER as cnt2SmHwAdapterOperState | |||
| INTEGER as cnt2SmHwAdapterAdminState | |||
| Cnt2SmHwCardEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmCardAdapterIndex | |||
| INTEGER as cnt2SmHwCardIndex | |||
| INTEGER as cnt2SmHwCardOperState | |||
| INTEGER as cnt2SmHwCardAdminState | |||
| Cnt2SmHwPowerSupplyEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmHwPowerSupplyIndex | |||
| INTEGER as cnt2SmHwPowerSupplyACState | |||
| INTEGER as cnt2SmHwPowerSupplyDCState | |||
| Cnt2SmHwFanEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmHwFanIndex | |||
| INTEGER as cnt2SmHwFanState | |||
| Cnt2SmSwEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmSwIndex | |||
| DisplayString as cnt2SmSwName | |||
| INTEGER as cnt2SmSwFunction | |||
| INTEGER as cnt2SmSwMajorVersion | |||
| INTEGER as cnt2SmSwMinorVersion | |||
| Cnt2SmMsgEntry | |||
| SEQUENCE | |||
| INTEGER as cnt2SmMsgIndex | |||
| INTEGER as cnt2SmMsgSeverity | |||
| DisplayString as cnt2SmMsgProcessName | |||
| INTEGER as cnt2SmMsgNumber | |||
| INTEGER as cnt2SmMsgSlotNumber | |||
| DisplayString as cnt2SmMsgDateTime | |||
| INTEGER as cnt2SmMsgErrorNumber | |||
| DisplayString as cnt2SmMsgContent | |||
| Cnt2SmMessageEntry | |||
| SEQUENCE | |||
| DisplayString as cnt2SmMessageText | |||
| INTEGER as cnt2SmMessageIndex | |||