COM21-HCXSTUPRXY-MIB

File: COM21-HCXSTUPRXY-MIB.mib (84421 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC COM21-HCX-MIB
COM21-HCXALM-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 IpAddress Gauge32
TimeTicks DisplayString MacAddress
com21 com21Hcx com21Stu
com21Traps hcxAlmSeverity hcxEventLogTime

Defined Objects

com21StuPrxy 1.3.6.1.4.1.1141.3.1
This is the Com21 ComController ComPort Proxy MIB. COM21 Part# 005-0025-00
MODULE-IDENTITY    

com21StuControlGroup 1.3.6.1.4.1.1141.3.2
OBJECT IDENTIFIER    

com21StuControlTable 1.3.6.1.4.1.1141.3.2.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuControlEntry

com21StuControlEntry 1.3.6.1.4.1.1141.3.2.1.1
.
OBJECT-TYPE    
  StuControlEntry  

stuCtrlMacAddress 1.3.6.1.4.1.1141.3.2.1.1.1
Contains IEEE 802 medium access control address of the ComPort device.
OBJECT-TYPE    
  MacAddress  

stuUserText 1.3.6.1.4.1.1141.3.2.1.1.2
The ComPort User Text is a non-volatile string which is set by the management system with an arbitrary value. This value does not have to be unique. It's purpose is solely to assist the carrier personnel with identifying the ComPort device.
OBJECT-TYPE    
  DisplayString SIZE(32)  

stuSerialNumber 1.3.6.1.4.1.1141.3.2.1.1.3
The Serial Number is a 10 character serial number used by COM21 to uniquely identify the device.
OBJECT-TYPE    
  DisplayString SIZE(16)  

stuBoardRevision 1.3.6.1.4.1.1141.3.2.1.1.4
This string defines the hardware revision of the ComPort board.
OBJECT-TYPE    
  DisplayString SIZE(16)  

stuUnitRevision 1.3.6.1.4.1.1141.3.2.1.1.5
This string defines the hardware revision of the complete ComPort unit.
OBJECT-TYPE    
  DisplayString SIZE(10)  

stuTunerRevision 1.3.6.1.4.1.1141.3.2.1.1.6
This string defines the hardware revision of the RF Tuner.
OBJECT-TYPE    
  DisplayString SIZE(10)  

stuModelName 1.3.6.1.4.1.1141.3.2.1.1.7
This string defines the ComPort Model Type.
OBJECT-TYPE    
  DisplayString SIZE(16)  

stuUnitManufacturer 1.3.6.1.4.1.1141.3.2.1.1.8
This string defines the manufacturer of the ComPort. Initially COM21 and 3COM.
OBJECT-TYPE    
  DisplayString SIZE(8)  

stuDesKeySize 1.3.6.1.4.1.1141.3.2.1.1.9
DES encryption key size supported by the ComPort.
OBJECT-TYPE    
  INTEGER bit56key(1), bit40key(2)  

stuMibRevision 1.3.6.1.4.1.1141.3.2.1.1.10
Indicates the Mib Revision as display string of max. 8 bytes. That includes string terminator.
OBJECT-TYPE    
  DisplayString SIZE(16)  

stuEpochTime 1.3.6.1.4.1.1141.3.2.1.1.11
ComPort time in seconds since 1970.
OBJECT-TYPE    
  EpochTime  

stuRestartAction 1.3.6.1.4.1.1141.3.2.1.1.12
The Restart Action is an active-value. The setting of this value is idempotent. The setting of this value to restart causes the STU to restart utilizing the present software load.
OBJECT-TYPE    
  INTEGER nil(1), restart(2)  

stuPrevTestResult 1.3.6.1.4.1.1141.3.2.1.1.13
Result of previous test. Presently this will be warm or cold restart.
OBJECT-TYPE    
  INTEGER success(1), failure(2)  

stuPrevTestFailCode 1.3.6.1.4.1.1141.3.2.1.1.14
Failure result code. Only set if stuPrevTestResult is equal to failure.
OBJECT-TYPE    
  INTEGER -32768..-1  

stuOperationState 1.3.6.1.4.1.1141.3.2.1.1.15
The ComPort Operational State is controlled either by the stuAdminState or locally detected conditions. Note that downloading and failedRanging are ComController helded states.
OBJECT-TYPE    
  INTEGER operational(1), deauthorized(2), offline(3), upstreamTest(4), etherLoopback(5), downloading(6), failedRanging(7)  

stuAimModuleId 1.3.6.1.4.1.1141.3.2.1.1.16
identifies the connected AIM module type. The maceEthernet entry indicates NO AIM inserted.
OBJECT-TYPE    
  INTEGER none(1), debugModule(2), teleReturn(3), telephony1(4), telephony2(5), wirelessEthernet(6), atm(7)  

stuUpstrmTestFreq 1.3.6.1.4.1.1141.3.2.1.1.17
Transmit Frequency used by ComPort for Upstream RF test. The default shall be 0 (an invalid freq).
OBJECT-TYPE    
  UpstrmFreqKhz  

stuInbPresent 1.3.6.1.4.1.1141.3.2.1.1.19
Indicates if the INB is present on the ComPORT. This is a future item not supported by present ComPORT hardware.
OBJECT-TYPE    
  INTEGER inbInstalled(1), noInbSupport(2), inbReady(3)  

stuInbContToneEnable 1.3.6.1.4.1.1141.3.2.1.1.20
Controls the activation of a continuous pilot tone. This does not effect the standard tone sent before data (which is controlled by a hardware switch). This value is not stored in NVRAM. Default is disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuLastRestartCause 1.3.6.1.4.1.1141.3.2.1.1.21
specifies the reason for the last ComPort reset.
OBJECT-TYPE    
  INTEGER unknown(1), hcxDirected(2), pingFail(3), imageRefresh(4), lof(5), fault(6)  

stuUpstrmPingCntrl 1.3.6.1.4.1.1141.3.2.1.1.22
used to control the upstream ping. Default is enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuUpstrmTestTimeout 1.3.6.1.4.1.1141.3.2.1.1.23
timeout used by ComPort for Upstream RF test. If the ComController does not terminate the test in this period - defined in seconds - then the ComPort will automatically reset, thus terminating the test. 0 means no timeout. Default is 0.
OBJECT-TYPE    
  INTEGER 0..86400  

stuDnstrmAltFreq 1.3.6.1.4.1.1141.3.2.1.1.24
Defines an alternate downstream frequency for the ComPort. This value is non-voltile. Default is 0 (an invalid freq). IMPORTANT - this is a tbd feature not available in 2.3 release.
OBJECT-TYPE    
  FrequencyKhz  

stuAsicRevision 1.3.6.1.4.1.1141.3.2.1.1.25
defines the revision of the ASIC. Presently values 1-255 are supported.
OBJECT-TYPE    
  INTEGER 1..255  

stuVoiceAimLpBk 1.3.6.1.4.1.1141.3.2.1.1.26
If a voiceAim Module is configured on the stu, setting the Aim Module to stuLpBk will configure the Aim Module to loopback from one voice port to the other. default: nil
OBJECT-TYPE    
  INTEGER nil(1), stuLpBk(2)  

stuVoiceAimPort1Status 1.3.6.1.4.1.1141.3.2.1.1.27
Describes whether the AimPort is onhook or offhook. default: nil
OBJECT-TYPE    
  INTEGER onHook(1), offHook(2)  

stuVoiceAimPort2Status 1.3.6.1.4.1.1141.3.2.1.1.28
Describes whether the AimPort is onhook or offhook. default: nil
OBJECT-TYPE    
  INTEGER onHook(1), offHook(2)  

com21StuPhysicalGroup 1.3.6.1.4.1.1141.3.3
OBJECT IDENTIFIER    

com21StuPhysicalTable 1.3.6.1.4.1.1141.3.3.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuPhysicalEntry

com21StuPhysicalEntry 1.3.6.1.4.1.1141.3.3.1.1
.
OBJECT-TYPE    
  StuPhysicalEntry  

stuPhyMacAddress 1.3.6.1.4.1.1141.3.3.1.1.1
Contains IEEE 802 medium access control address of the ComPort device.
OBJECT-TYPE    
  MacAddress  

stuXmitFrequency 1.3.6.1.4.1.1141.3.3.1.1.2
Contains the transmit frequency of the ComPort RF board in KHz. A change in this value shall result in the ComPort being hopped to a differing RX card. The Common Controller shall ensure the sanity of a change to this attribute and shall perform the necessary interface to the RX cards. The actual set of this attribute on the ComPort shall be performed by a GO_SET message.
OBJECT-TYPE    
  UpstrmFreqKhz  

stuRecvFrequency 1.3.6.1.4.1.1141.3.3.1.1.3
Contains the receive frequency in KHz. This attribute will match the downstream frequency of the ComController. The ONLY time when this should be change is when the NMAPS wishes hop the ComPort to a different ComController.
OBJECT-TYPE    
  FrequencyKhz  

stuRecvRfSrEstimate 1.3.6.1.4.1.1141.3.3.1.1.4
Received Signal S/R estimate in dB on Rf Downstream. This value is an approximation in dB. Received value should be divided by 10 to get a fixed point representation. e.g., value 185 means 18.5 dB.
OBJECT-TYPE    
  Integer32  

stuRecvRfSigLevel 1.3.6.1.4.1.1141.3.3.1.1.5
Received Signal Level in dBmv on Rf Downstream.
OBJECT-TYPE    
  Integer32  

stuXmitOffset 1.3.6.1.4.1.1141.3.3.1.1.6
Specifies the transmit offset of the ComPort.
OBJECT-TYPE    
  Offset  

stuXmitDacVRef 1.3.6.1.4.1.1141.3.3.1.1.7
Specifies the upstream RF DAC Voltage Reference. This value is set only via a GO_SET message under the control of the RX card.
OBJECT-TYPE    
  INTEGER 0..4294967295  

stuRecvFreqDrift 1.3.6.1.4.1.1141.3.3.1.1.8
Frequency shift (+/- 250Khz) from Downstream Frequency.
OBJECT-TYPE    
  INTEGER -250..250  

com21StuAlarmGroup 1.3.6.1.4.1.1141.3.4
OBJECT IDENTIFIER    

com21StuAlarmTable 1.3.6.1.4.1.1141.3.4.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuAlarmEntry

com21StuAlarmEntry 1.3.6.1.4.1.1141.3.4.1.1
.
OBJECT-TYPE    
  StuAlarmEntry  

stuAlmMacAddress 1.3.6.1.4.1.1141.3.4.1.1.1
Contains IEEE 802 medium access control address of the ComPort device.
OBJECT-TYPE    
  MacAddress  

stuAlmTime 1.3.6.1.4.1.1141.3.4.1.1.2
Specifies the time the alarm condition was detected.
OBJECT-TYPE    
  EpochTime  

stuAlmTrapId 1.3.6.1.4.1.1141.3.4.1.1.3
Specifies the trap number.
OBJECT-TYPE    
  INTEGER 100..200  

stuAlmSeverity 1.3.6.1.4.1.1141.3.4.1.1.4
Specifies the alarm severity.
OBJECT-TYPE    
  AlarmSeverity  

com21StuEtherConfigGroup 1.3.6.1.4.1.1141.3.5
OBJECT IDENTIFIER    

com21StuEtherConfigTable 1.3.6.1.4.1.1141.3.5.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuEtherConfigEntry

com21StuEtherConfigEntry 1.3.6.1.4.1.1141.3.5.1.1
.
OBJECT-TYPE    
  StuEtherConfigEntry  

stuEthMacAddress 1.3.6.1.4.1.1141.3.5.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuEtherFiltFlushAction 1.3.6.1.4.1.1141.3.5.1.1.2
Controls the flush operations.
OBJECT-TYPE    
  INTEGER none(1), flushMac(2), flushEtherType(3), flushIp(4)  

stuEtherForwArpOnly 1.3.6.1.4.1.1141.3.5.1.1.3
If enable state then only ARP broadcast packets are forwarded upstream. Default is disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherMacFiltAge 1.3.6.1.4.1.1141.3.5.1.1.4
Specifies the number of seconds that a learned MAC Address entry survives since last learning.
OBJECT-TYPE    
  INTEGER 0..4095  

stuEtherBCastRateEn 1.3.6.1.4.1.1141.3.5.1.1.5
Enable rate control. Default is disabled.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherBCastRateCo 1.3.6.1.4.1.1141.3.5.1.1.6
Limit of maximum number of broadcast packets per second allowed upstream.
OBJECT-TYPE    
  INTEGER 1..255  

stuEtherStickyBitCtrl 1.3.6.1.4.1.1141.3.5.1.1.7
When the Sticky Bit control is enabled, a MAC table entry will not be replaced by another MAC address for at least one aging period. Default disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEther8021QEnable 1.3.6.1.4.1.1141.3.5.1.1.8
Enables both 802.1Q priority queuing and the filter of 802.1Q format packets. Default disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherNonSnapRej 1.3.6.1.4.1.1141.3.5.1.1.9
This attribute controls the filtering of 802.2 non- SNAP encoded packets. Ethernet type filtering must be enabled to activate this feature. Default disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherIgmpEnable 1.3.6.1.4.1.1141.3.5.1.1.10
This attribute controls the forwarding of IGMP multicast traffic upstream. This attribute will override any other multicast filtering in the case of IGMP packets. Default is enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherNonIpMultiEn 1.3.6.1.4.1.1141.3.5.1.1.11
This attribute controls the forwarding of non-IP multicast traffic upstream. This attribute will override any other multicast filtering in the case of non-IP multicast packets. Default is enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherBcmpOnly 1.3.6.1.4.1.1141.3.5.1.1.12
When this attribute is enabled, all non-BCMP traffic will be rejected in both the upstream and downstream. This attribute is utilized in a Spannong Tree implementation. Default is disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

stuEtherIgmpSnoopEnable 1.3.6.1.4.1.1141.3.5.1.1.13
This attribute controls the snooping of IGMP multicast traffic upstream. Default is disable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

com21StuEtherTypeGroup 1.3.6.1.4.1.1141.3.6
OBJECT IDENTIFIER    

com21StuEtherTypeTable 1.3.6.1.4.1.1141.3.6.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuFiltEthTypeEntry

com21StuFiltEthTypeEntry 1.3.6.1.4.1.1141.3.6.1.1
Holds Ethernet Types codes that are to be passed upstream. Maximum of 6 entries.
OBJECT-TYPE    
  StuFiltEthTypeEntry  

stuFiltEtherMacAddr 1.3.6.1.4.1.1141.3.6.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuFiltEtherType 1.3.6.1.4.1.1141.3.6.1.1.2
Holds Ethernet Type codes that is to be passed upstream. Held on ComPort.
OBJECT-TYPE    
  INTEGER 1..65535  

stuFiltEtherStatus 1.3.6.1.4.1.1141.3.6.1.1.3
This attribute is used to create or delete Ethernet Type entry.
OBJECT-TYPE    
  Com21RowStatus  

com21StuFiltIpMultiGroup 1.3.6.1.4.1.1141.3.7
OBJECT IDENTIFIER    

com21StuFiltIpMultiTable 1.3.6.1.4.1.1141.3.7.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuFiltIpMultiEntry

com21StuFiltIpMultiEntry 1.3.6.1.4.1.1141.3.7.1.1
Holds IP Multicast Addresses that are to be allowed in either upstream, or downstream, or both directions. Maximum of 16 entries.
OBJECT-TYPE    
  StuFiltIpMultiEntry  

stuFiltIpMacAddr 1.3.6.1.4.1.1141.3.7.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuFiltIpMultiAddr 1.3.6.1.4.1.1141.3.7.1.1.2
Holds Multicast Address. Held on ComPort. Valid values are within the range of MAC addresses of 01.00.5E.00.00.00 to 01.00.5E.7F.FF.FF
OBJECT-TYPE    
  MacAddress  

stuFiltIpMultiStatus 1.3.6.1.4.1.1141.3.7.1.1.3
Used to delete or create an entry.
OBJECT-TYPE    
  Com21RowStatus  

stuFiltIpDirectCntrl 1.3.6.1.4.1.1141.3.7.1.1.4
Used to control the filter direction. Default is bothDirections.
OBJECT-TYPE    
  INTEGER upstreamOnly(1), downstreamOnly(2), bothDirections(3)  

com21StuEtherMacGroup 1.3.6.1.4.1.1141.3.8
OBJECT IDENTIFIER    

com21StuEtherMacTable 1.3.6.1.4.1.1141.3.8.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuEtherMacEntry

com21StuEtherMacEntry 1.3.6.1.4.1.1141.3.8.1.1
Holds Ethernet MAC address that are to be processed as specified. Maximum of 8 entries.
OBJECT-TYPE    
  StuEtherMacEntry  

stuEtherStuMac 1.3.6.1.4.1.1141.3.8.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuEtherMacAddr 1.3.6.1.4.1.1141.3.8.1.1.2
Holds MAC address. Held on ComPort.
OBJECT-TYPE    
  MacAddress  

stuEtherMacType 1.3.6.1.4.1.1141.3.8.1.1.3
Holds action to be performed upon packets of the specified MAC address. In the case of the learned MAC address, this entry becomes read only. Held on ComPort.
OBJECT-TYPE    
  INTEGER learned(1), processor(2), upstream(3), reject(4)  

stuEtherMacStatus 1.3.6.1.4.1.1141.3.8.1.1.4
Used to create or delete an entry.
OBJECT-TYPE    
  Com21RowStatus  

com21StuEtherStatsGroup 1.3.6.1.4.1.1141.3.9
OBJECT IDENTIFIER    

com21StuEtherStatsTable 1.3.6.1.4.1.1141.3.9.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuEtherStatsEntry

com21StuEtherStatsEntry 1.3.6.1.4.1.1141.3.9.1.1
.
OBJECT-TYPE    
  StuEtherStatsEntry  

stuEthStatsMacAddr 1.3.6.1.4.1.1141.3.9.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuCurrEtherRunts 1.3.6.1.4.1.1141.3.9.1.1.2
Contains number of runt packets received by the ComPort in the current 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherCollitns 1.3.6.1.4.1.1141.3.9.1.1.3
Contains number of collisions detected by the ComPort in the current 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherFramErrs 1.3.6.1.4.1.1141.3.9.1.1.4
Contains number of Ethernet Packets with Framing Errors detected by the ComPort in the current 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherCrcErrs 1.3.6.1.4.1.1141.3.9.1.1.5
Contains number of Ethernet Packets with CRC Errors detected by the ComPort in the current 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherCrcThres 1.3.6.1.4.1.1141.3.9.1.1.6
contains 15minute error level at which a threshold trap shall be generated. This is mapped to theComPort alarm severity entry stuThresholdLevel. Default is 0 - threshold disabled.
OBJECT-TYPE    
  Integer32  

stuCurrEtherTxUnder 1.3.6.1.4.1.1141.3.9.1.1.7
Contains number of times Ethernet TX FIFO Underflow occurred on transmit queue in the current 15minute period.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherRxOver 1.3.6.1.4.1.1141.3.9.1.1.8
Contains number of times Ethernet RX FIFO Overflow occurred on a receive queue in the current 15minute period.
OBJECT-TYPE    
  Gauge32  

stuCurrEtherDropFrms 1.3.6.1.4.1.1141.3.9.1.1.9
Contains number of receive frames dropped by MACE controller in the current 15minute period.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherRunts 1.3.6.1.4.1.1141.3.9.1.1.10
Contains number of runt packets received by the ComPort in the previous 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherCollitns 1.3.6.1.4.1.1141.3.9.1.1.11
Contains number of collisions detected by the ComPort in the previous 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherFramErrs 1.3.6.1.4.1.1141.3.9.1.1.12
Contains number of Ethernet Packets with Framing Errors detected by the ComPort in the previous 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherCrcErrs 1.3.6.1.4.1.1141.3.9.1.1.13
Contains number of Ethernet Packets with CRC Errors detected by the ComPort in the previous 15minute period. This data is held on the ComPort.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherTxUnder 1.3.6.1.4.1.1141.3.9.1.1.14
Contains number of times Ethernet TX FIFO Underflow occurred on transmit queue in the previous 15minute period.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherRxOver 1.3.6.1.4.1.1141.3.9.1.1.15
Contains number of times Ethernet RX FIFO Overflow occurred on a receive queue in the previous 15minute period.
OBJECT-TYPE    
  Gauge32  

stuPrevEtherDropFrms 1.3.6.1.4.1.1141.3.9.1.1.16
Contains number of receive frames dropped by MACE controller in the previous 15minute period.
OBJECT-TYPE    
  Gauge32  

stuEtherConnState 1.3.6.1.4.1.1141.3.9.1.1.17
Contains state of Ethernet connection.
OBJECT-TYPE    
  INTEGER unint(1), is(2), oos(3)  

stuEtherClearStats 1.3.6.1.4.1.1141.3.9.1.1.18
This attribute is used to clear all Ethernet statistics counters in this group. This operation is only possible if the hcxStatsControl attribute is set to wrapCurr.
OBJECT-TYPE    
  INTEGER nil(1), clear(2)  

com21StuStatsGroup 1.3.6.1.4.1.1141.3.10
OBJECT IDENTIFIER    

com21StuStatsTable 1.3.6.1.4.1.1141.3.10.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuStatsEntry

com21StuStatsEntry 1.3.6.1.4.1.1141.3.10.1.1
.
OBJECT-TYPE    
  StuStatsEntry  

stuStatsMacAddress 1.3.6.1.4.1.1141.3.10.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuStatsCurrAtmTei 1.3.6.1.4.1.1141.3.10.1.1.2
Number of cells received with transport errors - uncorrectable FEC or HEC errors - in the current 15minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmTeiThreshold 1.3.6.1.4.1.1141.3.10.1.1.3
contains 15minute transport error level at which a threshold trap shall be generated. Default is 0 - threshold disabled.
OBJECT-TYPE    
  Integer32  

stuStatsCurrAtmHec 1.3.6.1.4.1.1141.3.10.1.1.4
Number of cells received with HEC or Encryption errors in the current 15minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmHecThreshold 1.3.6.1.4.1.1141.3.10.1.1.5
contains 15minute HEC error level at which a threshold trap shall be generated. Default is 0 - threshold disabled.
OBJECT-TYPE    
  Integer32  

stuStatsCurrESMin 1.3.6.1.4.1.1141.3.10.1.1.6
Represents the number of errored seconds in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuESMinThreshold 1.3.6.1.4.1.1141.3.10.1.1.7
contains 15minute errored seconds level at which a threshold trap shall be generated. Default is 0 - threshold disabled.
OBJECT-TYPE    
  Integer32  

stuStatsCurrFecCorrect 1.3.6.1.4.1.1141.3.10.1.1.8
Fecs corrected by Demodulator on Downstream in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuFecCorrectThreshold 1.3.6.1.4.1.1141.3.10.1.1.9
contains 15minute Fecs corrected level at which a threshold trap shall be generated. Default is 0 - threshold disabled.
OBJECT-TYPE    
  Integer32  

stuStatsCurrUASMin 1.3.6.1.4.1.1141.3.10.1.1.10
Represents the number of unavailable seconds in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsPrevAtmTei 1.3.6.1.4.1.1141.3.10.1.1.11
Number of cells received with transport errors - HEC or uncorrectable FEC errors - in the previous 15minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsPrevAtmHec 1.3.6.1.4.1.1141.3.10.1.1.12
Number of cells received with HEC or Encryption errors in the previous 15minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsPrevESMin 1.3.6.1.4.1.1141.3.10.1.1.13
Represents the number of errored seconds in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsPrevFecCorrect 1.3.6.1.4.1.1141.3.10.1.1.14
Fecs corrected by Demodulator on Downstream in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsPrevUASMin 1.3.6.1.4.1.1141.3.10.1.1.15
Represents the number of unavailable seconds in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuStatsClearStats 1.3.6.1.4.1.1141.3.10.1.1.16
This attribute is used to clear the all ComPort statistics counters in this group. This operation is only possible if the hcxStatsControl attribute is set to wrapCurr.
OBJECT-TYPE    
  INTEGER nil(1), clear(2)  

com21StuQStatsGroup 1.3.6.1.4.1.1141.3.11
OBJECT IDENTIFIER    

com21StuQStatsTable 1.3.6.1.4.1.1141.3.11.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuQStatsEntry

com21StuQStatsEntry 1.3.6.1.4.1.1141.3.11.1.1
.
OBJECT-TYPE    
  StuQStatsEntry  

stuAtmStuMacAddr 1.3.6.1.4.1.1141.3.11.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuAtmStuQNo 1.3.6.1.4.1.1141.3.11.1.1.2
This index consists of a number representing a Mongoose queue. For initial phase this number shall equal the associated VCI number. i.e. Ethernet or Telephony VCIs. This VCI number shall be mapped to a Mongoose queue id by the ComController. For 3.0 there is only a single Ethernet queue - queue 5.
OBJECT-TYPE    
  Integer32  

stuAtmStatsCurrMinRx 1.3.6.1.4.1.1141.3.11.1.1.3
Represents the number of cells or frames successfully received in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsCurrMinRxDropped 1.3.6.1.4.1.1141.3.11.1.1.4
Represents the number of cells or frames dropped in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsCurrMinCRCErrors 1.3.6.1.4.1.1141.3.11.1.1.5
Represents the number of cells or frames received with CRC errors in the current 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsPrevMinRx 1.3.6.1.4.1.1141.3.11.1.1.6
Represents the number of cells or frames successfully received in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsPrevMinRxDropped 1.3.6.1.4.1.1141.3.11.1.1.7
Represents the number of cells or frames dropped in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsPrevMinCRCErrors 1.3.6.1.4.1.1141.3.11.1.1.8
Represents the number of cells or frames received with CRC errors in the previous 15 minute period.
OBJECT-TYPE    
  Gauge32  

stuAtmStatsClearStats 1.3.6.1.4.1.1141.3.11.1.1.9
This attribute is used to clear the ComPort queue statistics counters in this group. This operation is only possible if the hcxStatsControl attribute is set to wrapCurr.
OBJECT-TYPE    
  INTEGER nil(1), clear(2)  

com21StuAlarmSevGroup 1.3.6.1.4.1.1141.3.12
OBJECT IDENTIFIER    

com21StuAlarmSevTable 1.3.6.1.4.1.1141.3.12.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuAlarmSevEntry

com21StuAlarmSevEntry 1.3.6.1.4.1.1141.3.12.1.1
.
OBJECT-TYPE    
  StuAlarmSevEntry  

stuAlmSevMacAddress 1.3.6.1.4.1.1141.3.12.1.1.1
Contains IEEE 802 medium access control address of the ComPort device.
OBJECT-TYPE    
  MacAddress  

stuAlmSevCrcThres 1.3.6.1.4.1.1141.3.12.1.1.2
Specifies the CRC Error Threshold alarm severity. Default Minor.
OBJECT-TYPE    
  AlarmSeverity  

stuAlmSevTeiThres 1.3.6.1.4.1.1141.3.12.1.1.3
Specifies the TEI Threshold alarm severity. Default Minor.
OBJECT-TYPE    
  AlarmSeverity  

stuAlmSevHecThres 1.3.6.1.4.1.1141.3.12.1.1.4
Specifies the HEC Error Threshold alarm severity. Default Minor.
OBJECT-TYPE    
  AlarmSeverity  

stuAlmSevEsThres 1.3.6.1.4.1.1141.3.12.1.1.5
Specifies the Errored Seconds Threshold alarm severity. Default Minor.
OBJECT-TYPE    
  AlarmSeverity  

stuAlmSevFecThres 1.3.6.1.4.1.1141.3.12.1.1.6
Specifies the Corrected FEC Threshold alarm severity. Default Minor.
OBJECT-TYPE    
  AlarmSeverity  

com21StuCodeImageGroup 1.3.6.1.4.1.1141.3.13
OBJECT IDENTIFIER    

com21StuCodeImageTable 1.3.6.1.4.1.1141.3.13.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuCodeImageEntry

com21StuCodeImageEntry 1.3.6.1.4.1.1141.3.13.1.1
.
OBJECT-TYPE    
  StuCodeImageEntry  

stuCodeStuMacAddr 1.3.6.1.4.1.1141.3.13.1.1.1
Contains IEEE 802 medium access control address of the ComPort device. Held on ComController.
OBJECT-TYPE    
  MacAddress  

stuCodeImageIndex 1.3.6.1.4.1.1141.3.13.1.1.2
Index to receive information about various images; VxWorks - operating system. ApplicationStu - Image comprising Stu Application, DownloadImage - Image downloaded into DRAM.
OBJECT-TYPE    
  INTEGER vxWorksImage(1), applicationStu(2), downloadImage(3)  

stuCodeImageType 1.3.6.1.4.1.1141.3.13.1.1.3
Code image identifier. vxWorks - boot code and OS, boot memory resident, stuBoot - backup application image, boot memory resident, stuNewapp - primary application image, app memory resident, stuDnld - downloaded application supplement (optional), updateApp - downloaded flash update, updates app flash, updateBoth - downloaded flash update, updates boot+app flash.
OBJECT-TYPE    
  INTEGER stuBoot(1), reserved1(2), stuNewapp(3), stuDnld(4), updateApp(5), reserved2(6), reserved3(7), reserved4(8), updateBoth(9), reserved5(10), vxWorks(11)  

stuCodeImageVersion 1.3.6.1.4.1.1141.3.13.1.1.4
Version Description for the Code Image.
OBJECT-TYPE    
  DisplayString SIZE(40)  

stuCodeImageBuildDir 1.3.6.1.4.1.1141.3.13.1.1.5
Directory name where image was built.
OBJECT-TYPE    
  DisplayString SIZE(80)  

stuCodeImageDate 1.3.6.1.4.1.1141.3.13.1.1.6
Date when the image is built.
OBJECT-TYPE    
  DisplayString SIZE(12)  

stuCodeImageTime 1.3.6.1.4.1.1141.3.13.1.1.7
Time when the image is built.
OBJECT-TYPE    
  DisplayString SIZE(9)  

com21StuVoiceChanStatsGroup 1.3.6.1.4.1.1141.3.14
OBJECT IDENTIFIER    

com21StuVoiceChanStatsTable 1.3.6.1.4.1.1141.3.14.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    StuVoiceChanStatsEntry

com21StuVoiceChanStatsEntry 1.3.6.1.4.1.1141.3.14.1.1
.
OBJECT-TYPE    
  StuVoiceChanStatsEntry  

stuVoiceChanStatsMacAddr 1.3.6.1.4.1.1141.3.14.1.1.1
Contains IEEE 802 medium access control address of the ComPort device.
OBJECT-TYPE    
  MacAddress  

stuVoiceChanStatsNum 1.3.6.1.4.1.1141.3.14.1.1.2
Defines the voice port on the Comport device used for Voice.
OBJECT-TYPE    
  INTEGER 1..2  

stuVoiceChanStatsCurrLostCellCnt 1.3.6.1.4.1.1141.3.14.1.1.3
Defines the number of times the Comport's voice port received Cells out of sequence in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrDrpdCellCnt 1.3.6.1.4.1.1141.3.14.1.1.4
Defines the number of times the Comport's voice port dropped cells due to Queue Full in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrCrc3ErrCnt 1.3.6.1.4.1.1141.3.14.1.1.5
Defines the number of cells Comport's voice port received with CRC3 Errors in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrSetUpFailCnt 1.3.6.1.4.1.1141.3.14.1.1.6
Defines the number of times the Comport's voice port had to drop the calls due to Call Setup Failure in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrTxVoiceCellCnt 1.3.6.1.4.1.1141.3.14.1.1.7
Defines the number of Voice cells Comport's voice port Queued to Transmit in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrRxVoiceCellCnt 1.3.6.1.4.1.1141.3.14.1.1.8
Defines the number of Voice cells the Comport's voice port received in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrTxOamCellCnt 1.3.6.1.4.1.1141.3.14.1.1.9
Defines the number of OAM cells Comport's voice port Queued to Transmit in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsCurrRxOamCellCnt 1.3.6.1.4.1.1141.3.14.1.1.10
Defines the number of OAM cells the Comport's voice port received in the current 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevLostCellCnt 1.3.6.1.4.1.1141.3.14.1.1.11
Defines the number of times the Comport's voice port received Cells out of sequence in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevDrpdCellCnt 1.3.6.1.4.1.1141.3.14.1.1.12
Defines the number of times the Comport's voice port dropped cells due to Queue Full in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevCrc3ErrCnt 1.3.6.1.4.1.1141.3.14.1.1.13
Defines the number of cells Comport's voice port received with CRC3 Errors in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevSetUpFailCnt 1.3.6.1.4.1.1141.3.14.1.1.14
Defines the number of times the Comport's voice port had to drop the calls due to Call Setup Failure in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevTxVoiceCellCnt 1.3.6.1.4.1.1141.3.14.1.1.15
Defines the number of Voice cells Comport's voice port Tranmitted in the previous 15-min period
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevRxVoiceCellCnt 1.3.6.1.4.1.1141.3.14.1.1.16
Defines the number of times the Comport's voice port received Cells out of sequence in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevTxOamCellCnt 1.3.6.1.4.1.1141.3.14.1.1.17
Defines the number of times the Comport's voice port received Cells out of sequence in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsPrevRxOamCellCnt 1.3.6.1.4.1.1141.3.14.1.1.18
Defines the number of times the Comport's voice port received Cells out of sequence in the previous 15-min period.
OBJECT-TYPE    
  Integer32  

stuVoiceChanStatsClear 1.3.6.1.4.1.1141.3.14.1.1.19
Provides the capability to clear the statistics. Clearing of statistics allowed only if hcxStatsControl attribute is set to wrapCurr.
OBJECT-TYPE    
  INTEGER nil(1), clear(2)  

stuOperationStateChange 1.3.6.1.4.1.1141.4.110
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuCtrlMacAddress  
  stuOperationState  

stuXmitFeqChange 1.3.6.1.4.1.1141.4.111
This trap is generated whenever an ComPort is hopped. It will not be generated at initial acquisition.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuPhyMacAddress  
  stuXmitFrequency  

stuEtherCrcThres 1.3.6.1.4.1.1141.4.112
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuEthStatsMacAddr  
  stuCurrEtherCrcErrs  
  stuCurrEtherCrcThres  

stuAtmTeiThres 1.3.6.1.4.1.1141.4.113
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuStatsMacAddress  
  stuStatsCurrAtmTei  
  stuAtmTeiThreshold  

stuAtmHecThres 1.3.6.1.4.1.1141.4.114
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuStatsMacAddress  
  stuStatsCurrAtmHec  
  stuAtmHecThreshold  

stuESMinThres 1.3.6.1.4.1.1141.4.115
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuStatsMacAddress  
  stuStatsCurrESMin  
  stuESMinThreshold  

stuFecCorrectThres 1.3.6.1.4.1.1141.4.116
.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuStatsMacAddress  
  stuStatsCurrFecCorrect  
  stuFecCorrectThreshold  

stuOutOfSpecRFCond 1.3.6.1.4.1.1141.4.117
This trap is generated whenever an ComPort is acquired with out of spec signal quality condition. The trap trap is issued after the GO-SET-DONE message.
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuPhyMacAddress  
  stuRecvRfSigLevel  

stuMaceFail 1.3.6.1.4.1.1141.4.119
This trap would be sent after ComPort is completely booted. That is, at least download is completed. Event will be detected during POST (Power On Self Test)
NOTIFICATION-TYPE    
  stuAlmSeverity  
  stuAlmTime  
  stuCtrlMacAddress  

Defined Objects

FrequencyKhz  
INTEGER 0..800000    

UpstrmFreqKhz  
INTEGER 5000..40000    

EpochTime  
INTEGER 0..2147483647    

Offset  
INTEGER 0..16383    

AlarmSeverity  
INTEGER clear(1), warning(2), minor(3), major(4), critical(5)    

Com21RowStatus  
INTEGER active(1), create(2), destroy(3), deactive(4)    

StuControlEntry  
SEQUENCE    
  MacAddress as stuCtrlMacAddress  
  DisplayString as stuUserText  
  DisplayString as stuSerialNumber  
  DisplayString as stuBoardRevision  
  DisplayString as stuUnitRevision  
  DisplayString as stuTunerRevision  
  DisplayString as stuModelName  
  DisplayString as stuUnitManufacturer  
  INTEGER as stuDesKeySize  
  DisplayString as stuMibRevision  
  EpochTime as stuEpochTime  
  INTEGER as stuRestartAction  
  INTEGER as stuPrevTestResult  
  INTEGER as stuPrevTestFailCode  
  INTEGER as stuOperationState  
  INTEGER as stuAimModuleId  
  UpstrmFreqKhz as stuUpstrmTestFreq  
  INTEGER as stuInbPresent  
  INTEGER as stuInbContToneEnable  
  INTEGER as stuLastRestartCause  
  INTEGER as stuUpstrmPingCntrl  
  INTEGER as stuUpstrmTestTimeout  
  FrequencyKhz as stuDnstrmAltFreq  
  INTEGER as stuAsicRevision  
  INTEGER as stuVoiceAimLpBk  
  INTEGER as stuVoiceAimPort1Status  
  INTEGER as stuVoiceAimPort2Status  

StuPhysicalEntry  
SEQUENCE    
  MacAddress as stuPhyMacAddress  
  UpstrmFreqKhz as stuXmitFrequency  
  FrequencyKhz as stuRecvFrequency  
  Integer32 as stuRecvRfSrEstimate  
  Integer32 as stuRecvRfSigLevel  
  Offset as stuXmitOffset  
  INTEGER as stuXmitDacVRef  
  INTEGER as stuRecvFreqDrift  

StuAlarmEntry  
SEQUENCE    
  MacAddress as stuAlmMacAddress  
  EpochTime as stuAlmTime  
  INTEGER as stuAlmTrapId  
  AlarmSeverity as stuAlmSeverity  

StuAlarmSevEntry  
SEQUENCE    
  MacAddress as stuAlmSevMacAddress  
  INTEGER as stuAlmSevCrcThres  
  INTEGER as stuAlmSevTeiThres  
  INTEGER as stuAlmSevHecThres  
  INTEGER as stuAlmSevEsThres  
  INTEGER as stuAlmSevFecThres  

StuEtherConfigEntry  
SEQUENCE    
  MacAddress as stuEthMacAddress  
  INTEGER as stuEtherFiltFlushAction  
  INTEGER as stuEtherForwArpOnly  
  INTEGER as stuEtherMacFiltAge  
  INTEGER as stuEtherBCastRateEn  
  INTEGER as stuEtherBCastRateCo  
  INTEGER as stuEtherStickyBitCtrl  
  INTEGER as stuEther8021QEnable  
  INTEGER as stuEtherNonSnapRej  
  INTEGER as stuEtherIgmpEnable  
  INTEGER as stuEtherNonIpMultiEn  
  INTEGER as stuEtherBcmpOnly  
  INTEGER as stuEtherIgmpSnoopEnable  

StuFiltEthTypeEntry  
SEQUENCE    
  MacAddress as stuFiltEtherMacAddr  
  INTEGER as stuFiltEtherType  
  Com21RowStatus as stuFiltEtherStatus  

StuFiltIpMultiEntry  
SEQUENCE    
  MacAddress as stuFiltIpMacAddr  
  MacAddress as stuFiltIpMultiAddr  
  Com21RowStatus as stuFiltIpMultiStatus  
  INTEGER as stuFiltIpDirectCntrl  

StuEtherMacEntry  
SEQUENCE    
  MacAddress as stuEtherStuMac  
  MacAddress as stuEtherMacAddr  
  INTEGER as stuEtherMacType  
  Com21RowStatus as stuEtherMacStatus  

StuEtherStatsEntry  
SEQUENCE    
  MacAddress as stuEthStatsMacAddr  
  Gauge32 as stuCurrEtherRunts  
  Gauge32 as stuCurrEtherCollitns  
  Gauge32 as stuCurrEtherFramErrs  
  Gauge32 as stuCurrEtherCrcErrs  
  Integer32 as stuCurrEtherCrcThres  
  Gauge32 as stuCurrEtherTxUnder  
  Gauge32 as stuCurrEtherRxOver  
  Gauge32 as stuCurrEtherDropFrms  
  Gauge32 as stuPrevEtherRunts  
  Gauge32 as stuPrevEtherCollitns  
  Gauge32 as stuPrevEtherFramErrs  
  Gauge32 as stuPrevEtherCrcErrs  
  Gauge32 as stuPrevEtherTxUnder  
  Gauge32 as stuPrevEtherRxOver  
  Gauge32 as stuPrevEtherDropFrms  
  INTEGER as stuEtherConnState  
  INTEGER as stuEtherClearStats  

StuStatsEntry  
SEQUENCE    
  MacAddress as stuStatsMacAddress  
  Gauge32 as stuStatsCurrAtmTei  
  Integer32 as stuAtmTeiThreshold  
  Gauge32 as stuStatsCurrAtmHec  
  Integer32 as stuAtmHecThreshold  
  Gauge32 as stuStatsCurrESMin  
  Integer32 as stuESMinThreshold  
  Gauge32 as stuStatsCurrFecCorrect  
  Integer32 as stuFecCorrectThreshold  
  Gauge32 as stuStatsCurrUASMin  
  Gauge32 as stuStatsPrevAtmTei  
  Gauge32 as stuStatsPrevAtmHec  
  Gauge32 as stuStatsPrevESMin  
  Gauge32 as stuStatsPrevFecCorrect  
  Gauge32 as stuStatsPrevUASMin  
  INTEGER as stuStatsClearStats  

StuQStatsEntry  
SEQUENCE    
  MacAddress as stuAtmStuMacAddr  
  Integer32 as stuAtmStuQNo  
  Gauge32 as stuAtmStatsCurrMinRx  
  Gauge32 as stuAtmStatsCurrMinRxDropped  
  Gauge32 as stuAtmStatsCurrMinCRCErrors  
  Gauge32 as stuAtmStatsPrevMinRx  
  Gauge32 as stuAtmStatsPrevMinRxDropped  
  Gauge32 as stuAtmStatsPrevMinCRCErrors  
  INTEGER as stuAtmStatsClearStats  

StuCodeImageEntry  
SEQUENCE    
  MacAddress as stuCodeStuMacAddr  
  INTEGER as stuCodeImageIndex  
  INTEGER as stuCodeImageType  
  DisplayString as stuCodeImageVersion  
  DisplayString as stuCodeImageBuildDir  
  DisplayString as stuCodeImageDate  
  DisplayString as stuCodeImageTime  

StuVoiceChanStatsEntry  
SEQUENCE    
  MacAddress as stuVoiceChanStatsMacAddr  
  INTEGER as stuVoiceChanStatsNum  
  Gauge32 as stuVoiceChanStatsCurrLostCellCnt  
  Gauge32 as stuVoiceChanStatsCurrDrpdCellCnt  
  Gauge32 as stuVoiceChanStatsCurrCrc3ErrCnt  
  Gauge32 as stuVoiceChanStatsCurrSetUpFailCnt  
  Gauge32 as stuVoiceChanStatsCurrTxVoiceCellCnt  
  Gauge32 as stuVoiceChanStatsCurrRxVoiceCellCnt  
  Gauge32 as stuVoiceChanStatsCurrTxOamCellCnt  
  Gauge32 as stuVoiceChanStatsCurrRxOamCellCnt  
  Gauge32 as stuVoiceChanStatsPrevLostCellCnt  
  Gauge32 as stuVoiceChanStatsPrevDrpdCellCnt  
  Gauge32 as stuVoiceChanStatsPrevCrc3ErrCnt  
  Gauge32 as stuVoiceChanStatsPrevSetUpFailCnt  
  Gauge32 as stuVoiceChanStatsPrevTxVoiceCellCnt  
  Gauge32 as stuVoiceChanStatsPrevRxVoiceCellCnt  
  Gauge32 as stuVoiceChanStatsPrevTxOamCellCnt  
  Gauge32 as stuVoiceChanStatsPrevRxOamCellCnt  
  INTEGER as stuVoiceChanStatsClear