CONTIVITY-TRAPS-V1-MIB

File: CONTIVITY-TRAPS-V1-MIB.mib (80661 bytes)

Imported modules

RFC1213-MIB RFC-1212 RFC-1215
RFC1155-SMI SNMPv2-SMI NEWOAK-MIB

Imported symbols

DisplayString sysName sysObjectID
ifIndex ifAdminStatus ifOperStatus
ifType ifDescr snmp
OBJECT-TYPE TRAP-TYPE IpAddress
MODULE-IDENTITY contivity

Defined Objects

coldStart 1.3.6.1.2.1.11.0
A coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered.
TRAP-TYPE    

linkDown 1.3.6.1.2.1.11.2
A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration. Varbind list: ifIndex -- ifIndex of the interface. ifAdminStatus -- ifAdminStatus of the interface. ifOperStatus -- ifOperStatus of the interface. ifDescr -- ifDescr of the interface. ifType -- ifType, this provides descrimination of interfaces that are tunnels. ifReasonForStatus-ces -- reason for the change in status. ifPhysLocation-ces -- this is the slot number. ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation. ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel. ifName-ces -- Name of the tunnel or physical interface. ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero. sysObjectID -- sysObjectID of the unit. sysName -- sysName of the unit.
TRAP-TYPE    
  ifIndex  
  ifAdminStatus  
  ifOperStatus  
  ifDescr  
  ifType  
  ifReasonForStatus-ces  
  ifPhysLocation-ces  
  ifPhysRelPos-ces  
  ifIpAddr-ces  
  ifName-ces  
  ifTunnelRemoteIpAddr-ces  
  sysObjectID  
  sysName  

linkUp 1.3.6.1.2.1.11.3
A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up. Varbind list: ifIndex -- ifIndex of the interface. ifAdminStatus -- ifAdminStatus of the interface. ifOperStatus -- ifOperStatus of the interface. ifDescr -- ifDescr of the interface. ifType -- ifType, this provides descrimination of interfaces that are tunnels. ifReasonForStatus-ces -- reason for the change in status ifPhysLocation-ces -- this is the slot number. ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation. ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel. ifName-ces -- Name of the tunnel or physical interface. ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero. sysObjectID -- sysObjectID of the unit. sysName -- sysName of the unit.
TRAP-TYPE    
  ifIndex  
  ifAdminStatus  
  ifOperStatus  
  ifDescr  
  ifType  
  ifReasonForStatus-ces  
  ifPhysLocation-ces  
  ifPhysRelPos-ces  
  ifIpAddr-ces  
  ifName-ces  
  ifTunnelRemoteIpAddr-ces  
  sysObjectID  
  sysName  

authenticationFailure 1.3.6.1.2.1.11.5
An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. The snmpEnableAuthenTraps object indicates whether this trap will be generated. snmpAuthenOperation-ces identifies the operation( ie. GetRequest, GetNextRequest,... ) was being attempted. snmpAuthenIpAddress-ces identifies the source IP address of the operation. snmpAuthenCommString-ces identifies the community string that was used in the operation.
TRAP-TYPE    
  snmpAuthenOperation-ces  
  snmpAuthenIpAddress-ces  
  snmpAuthenCommString-ces  
  sysObjectID  
  sysName  

contivityTrapsV1 1.3.6.1.4.1.2505.1.0
This MIB defines the traps, and bind objects used in the traps, that are sent by the Convitiy Extranet Switch.
MODULE-IDENTITY    

hardwareCESTrapInfo 1.3.6.1.4.1.2505.1.1
OBJECT IDENTIFIER    

hardDisk1Status 1.3.6.1.4.1.2505.1.1.1
Hard Disk Number 1 Status. Possible Values: Warning: Hard Disk 1 : Device /ide1/ not available Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/ Alert: Hard Disk 1 : Utilization exceeds 87.5%% on /ide1/
OBJECT-TYPE    
  DisplayString  

hardDisk0Status 1.3.6.1.4.1.2505.1.1.2
Hard Disk Number 0 Status. Possible Values: Warning: Hard Disk 0 : Device /ide0/ not available Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/ Alert: Hard Disk 0 : Utilization exceeds 87.5%% on /ide0/
OBJECT-TYPE    
  DisplayString  

memoryUsage 1.3.6.1.4.1.2505.1.1.3
Memory Usage Status. Possible Values: Warning: Memory Usage : Utilization exceeds 75% Alert: Memory Usage : Utilization exceeds 87.5%
OBJECT-TYPE    
  DisplayString  

lanCardStatus 1.3.6.1.4.1.2505.1.1.4
Status of any LAN cards on the system. Possible Values: Please note that X corresponds to the Xth slot in the system. Please note that Y corresponds to the relative position of the port on the card in the Xth slot in the system. Warning: LAN on Slot X Interface Y: Device feiX has no IP address; Warning: LAN on Slot X Interface Y: Device feiX disabled; Alert: LAN on Slot X Interface Y: Device feiX down; Alert: LAN on Slot X Interface Y: Device feiX Invalid Device X The Alert status above indicates that the interface has no link when it should. Possible causes are improper connection speeds and duplex, improper cabling or a configuration issue.
OBJECT-TYPE    
  DisplayString  

cpuTwoStatus 1.3.6.1.4.1.2505.1.1.5
Status of second CPU. Possible Values: Alert: CPU 2: Program load failed; Alert: CPU 2: Bootup did not complete; Alert: CPU 2: Communication lost; Alert: CPU 2: Failed. Reason unknown; Each of these indicates that the application CPU is not functioning correctly. The system will continue to function without the application processor. This can only be sent from a system with multiple CPUs. See the Admin Guide for a list of systems that contain multiple CPUs. The CES will emit an audible alarm and the networking performance will be degraded. A Nortel Networks support representative should be contacted if rese ing the CES does not correct the problem. The effect is the same in each case. The system will be running with only one CPU.
OBJECT-TYPE    
  DisplayString  

fanOneStatus 1.3.6.1.4.1.2505.1.1.6
Status of the first CPU fan. Possible Values: Alert: CPU One Fan: Fan not functioning; This indicates that the fan on the primary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the primary CPU.
OBJECT-TYPE    
  DisplayString  

fanTwoStatus 1.3.6.1.4.1.2505.1.1.7
Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the auxiliary CPU.
OBJECT-TYPE    
  DisplayString  

chassisFanStatus 1.3.6.1.4.1.2505.1.1.8
Status of the chassis fan. Possible Values: Alert: Chassis Fan: Fan not functioning; Alert: Chassis Fan 2: Fan not functioning; This indicates that one of the chassis fans is running either below the specified range of speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. If either of the fans are not working properly, the box must be looked at by a service technician as soon as possible. Not doing so will result in overheating of the system, improper system operation, and possible component failure.
OBJECT-TYPE    
  DisplayString  

fiveVoltsPositive 1.3.6.1.4.1.2505.1.1.9
Status of +5 Volt power. Possible Values: Alert: Voltage 5 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

fiveVoltsMinus 1.3.6.1.4.1.2505.1.1.10
Status of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

threeVoltsPositive 1.3.6.1.4.1.2505.1.1.11
Status of +3 Volt power. Possible Values: Alert: Voltage 3.3 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

twoDotFiveVA 1.3.6.1.4.1.2505.1.1.12
Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

twoDotFiveVB 1.3.6.1.4.1.2505.1.1.13
Status of 2.5VB power. Possible Values: Alert: Voltage 2.5 VB: Voltage out of range; This is the voltage supplied to the seconary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

twelveVoltsPositive 1.3.6.1.4.1.2505.1.1.14
Status of +12 Volt power. Possible Values: Alert: Voltage 12 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

twelveVoltsMinus 1.3.6.1.4.1.2505.1.1.15
Status of -12 Volt power. Possible Values: Alert: Voltage 12 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
OBJECT-TYPE    
  DisplayString  

normalTemperature 1.3.6.1.4.1.2505.1.1.16
Status of normal temperature reading. Possible Values: Alert: Normal Temperature: Normal temperature out of range; This indicates that the box is running above its rated normal operating temperature. This may be the result of an improperly working fan or a high ambient temperature. The box is not guaranteed to run properly while running above the normal operating temperature range. Performance will be degraded. Not taking action to correct this situation can result in component failure. Do not rely on waiting for the criticalTemperatureTrap as that is only supported by certain platforms.
OBJECT-TYPE    
  DisplayString  

criticalTemperature 1.3.6.1.4.1.2505.1.1.17
Status of critical temperature reading. Possible Values: Alert: Critical Temperature: Critial temperature out of range; This indicates that the box is running at a critically high temperature above the normal operating range. This is only supported on certain platforms. See the Admin Guide for a list of platforms which support this. The box must be shut down immediately. Component failure may already have occurred. If the reason for such a high operating temperature cannot be determined, contact a qualified Nortel Networks representative.
OBJECT-TYPE    
  DisplayString  

chassisIntrusion 1.3.6.1.4.1.2505.1.1.18
The chassis intrusion sensor indicates that the unit has been opened. Possible Values: Alert: Intrusion: Box has been opened; The cover to the CES has been opened or is in the process of being opened. This indicates a possible physical security intrusion. The system will continue to operate while the box is opened. Check to insure that no unauthorized persons have opened the unit.
OBJECT-TYPE    
  DisplayString  

dualPowerSupply 1.3.6.1.4.1.2505.1.1.19
Status of the redundant power supplies. Possible Values: Alert: Dual Power Supply: Redundant supply faulted This indicates that, on systems with redundant power supplies, one of the power supplies is not working. This trap can only be sent from systems which have redundant power supplies. The system will continue to run with only one power supply working. A new power supply must be obtained via an authorized Nortel Networks representative as quickly as possible. This will help reduce the risk window of system failure in the event that the working power supply ceases to function.
OBJECT-TYPE    
  DisplayString  

t1WANStatus 1.3.6.1.4.1.2505.1.1.20
Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
OBJECT-TYPE    
  DisplayString  

t3WANStatus 1.3.6.1.4.1.2505.1.1.21
Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
OBJECT-TYPE    
  DisplayString  

hwAccelStatus 1.3.6.1.4.1.2505.1.1.22
Status of hardware accelerator card.
OBJECT-TYPE    
  DisplayString  

hardDisk1StatusTrap 1.3.6.1.4.1.2505.1.1.1001
Hard Disk Number 1 Status
TRAP-TYPE    
  severityLevel  
  hardDisk1Status  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

hardDisk0StatusTrap 1.3.6.1.4.1.2505.1.1.1002
Hard Disk Number 0 Status
TRAP-TYPE    
  severityLevel  
  hardDisk0Status  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

memoryUsageTrap 1.3.6.1.4.1.2505.1.1.1003
Memory Usage Status
TRAP-TYPE    
  severityLevel  
  memoryUsage  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

lanCardStatusTrap 1.3.6.1.4.1.2505.1.1.1004
Status of any LAN cards on the system
TRAP-TYPE    
  severityLevel  
  lanCardStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  
  ifIndex  
  ifDescr  
  ifType  

cpuTwoStatusTrap 1.3.6.1.4.1.2505.1.1.1005
Status of second CPU.
TRAP-TYPE    
  severityLevel  
  cpuTwoStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fanOneStatusTrap 1.3.6.1.4.1.2505.1.1.1006
Status of the first CPU fan
TRAP-TYPE    
  severityLevel  
  fanOneStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fanTwoStatusTrap 1.3.6.1.4.1.2505.1.1.1007
Status of the second CPU fan
TRAP-TYPE    
  severityLevel  
  fanTwoStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

chassisFanStatusTrap 1.3.6.1.4.1.2505.1.1.1008
Status of the chassis fan.
TRAP-TYPE    
  severityLevel  
  chassisFanStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fiveVoltsPosStatusTrap 1.3.6.1.4.1.2505.1.1.1009
Status of the +5 Volt power
TRAP-TYPE    
  severityLevel  
  fiveVoltsPositive  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fiveVoltsMinusTrap 1.3.6.1.4.1.2505.1.1.10010
Status of -5 Volt power
TRAP-TYPE    
  severityLevel  
  fiveVoltsMinus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

threeVoltsPositiveTrap 1.3.6.1.4.1.2505.1.1.10011
Status of +3 Volt power
TRAP-TYPE    
  severityLevel  
  threeVoltsPositive  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

twoDotFiveVATrap 1.3.6.1.4.1.2505.1.1.10012
Status of 2.5VA power
TRAP-TYPE    
  severityLevel  
  twoDotFiveVA  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

twoDotFiveVBTrap 1.3.6.1.4.1.2505.1.1.10013
Status of 2.5VB power
TRAP-TYPE    
  severityLevel  
  twoDotFiveVB  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

twelveVoltsPositveTrap 1.3.6.1.4.1.2505.1.1.10014
Status of +12 Volt power
TRAP-TYPE    
  severityLevel  
  twelveVoltsPositive  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

twelveVoltsMinsTrap 1.3.6.1.4.1.2505.1.1.10015
Status of -12 Volt power
TRAP-TYPE    
  severityLevel  
  twelveVoltsMinus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

normalTemperatureTrap 1.3.6.1.4.1.2505.1.1.10016
Status of the normal temperature reading
TRAP-TYPE    
  severityLevel  
  normalTemperature  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

criticalTemperatureTrap 1.3.6.1.4.1.2505.1.1.10017
Status of the critical temperature reading
TRAP-TYPE    
  severityLevel  
  criticalTemperature  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

chassisIntrusionTrap 1.3.6.1.4.1.2505.1.1.10018
The chassis intrusion sensor indicates that the unit has been physically opened
TRAP-TYPE    
  severityLevel  
  chassisIntrusion  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

dualPowerSupplyTrap 1.3.6.1.4.1.2505.1.1.10019
Status of the redundant power supplies
TRAP-TYPE    
  severityLevel  
  dualPowerSupply  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

t1WANStatusTrap 1.3.6.1.4.1.2505.1.1.10020
Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
TRAP-TYPE    
  severityLevel  
  t1WANStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  
  ifIndex  
  ifDescr  
  ifType  

t3WANStatusTrap 1.3.6.1.4.1.2505.1.1.10021
Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
TRAP-TYPE    
  severityLevel  
  t3WANStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  
  ifIndex  
  ifDescr  
  ifType  

hwAccelTrap 1.3.6.1.4.1.2505.1.1.10022
Status of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED; Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED; Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE; Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING; Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN; Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
TRAP-TYPE    
  severityLevel  
  hwAccelStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

serverCESTrapInfo 1.3.6.1.4.1.2505.1.2
OBJECT IDENTIFIER    

radiusAcctServer 1.3.6.1.4.1.2505.1.2.1
Status of External Radius Accounting Server. Possible Values: Warning: RADIUS Accounting Server: Server not configured Alert: RADIUS Accounting Server: Error Alert: RADIUS Accounting Server: Not Configured
OBJECT-TYPE    
  DisplayString  

backupServer 1.3.6.1.4.1.2505.1.2.2
Status of External Disk Backup Server. Possible Values: Warning: Auto Backup Servers: Server not configured. Warning: Auto Backup Servers: Can't backup to xxx yyy zzz Alert: Auto Backup Servers: Can't backup to xxx yyy zzz Can't backup to xxx yyy zzz is issued as an alert when none of the servers can be reached.
OBJECT-TYPE    
  DisplayString  

diskRedundency 1.3.6.1.4.1.2505.1.2.3
Status of Local Disk Redundency. Possible Values: Alert: Disk Redundancy: Not Configured Alert: Disk Redundancy: Error
OBJECT-TYPE    
  DisplayString  

intLDAPServer 1.3.6.1.4.1.2505.1.2.4
Status of Internal LDAP Server. Possible Values: Warning : Internal LDAP Server : Restore in progress Alert : Internal LDAP Server : Server is down
OBJECT-TYPE    
  DisplayString  

loadBalancingServer 1.3.6.1.4.1.2505.1.2.5
Status of Load Balancing Server. Possible Values: Disabled: Load Balancing Service: Server not enabled; Warning: Load Balancing Service: Timed out waiting for response from server;
OBJECT-TYPE    
  DisplayString  

dnsServer 1.3.6.1.4.1.2505.1.2.6
Status of DNS Server. Possible Values: Warning: DNS Servers : Error Warning: DNS Servers : Operational Alert: DNS Servers : Configured Alert: DNS Servers : Error The values have the following meaning: Warning: DNS Servers : Error -- SysInitCls::InitComplete failed Warning: DNS Servers : Operational -- At least one of the servers is reachable Alert: DNS Servers : Configured -- All servers configured, but none are reachable. Alert: DNS Servers : Error --
OBJECT-TYPE    
  DisplayString  

snmpServer 1.3.6.1.4.1.2505.1.2.7
Status of SNMP Server. Possible Values: Warning: SNMP Servers : Error Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy Alert: SNMP Servers : Error The values have the following meaning: Warning: SNMP Servers : Error -- SysInitCls::InitComplete failed Alert: SNMP Servers : Error -- AT least one server configured, but none are reachable.
OBJECT-TYPE    
  DisplayString  

ipAddressPool 1.3.6.1.4.1.2505.1.2.8
Status of the IP address pool. Possible Values: Warning: IP Address Pool : Reserved address count is low. Warning: IP Address Pool : DHCP server(s) unavailable Alert: IP Address Pool : Server is down Alert: IP Address Pool : Not Configured Alert: IP Address Pool : No IP address available. Alert: IP Address Pool : Reserved address count is low. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Error The values have the following meaning: Warning: IP Address Pool : Reserved address count is low. -- Haven't hit desired cache size yet. Alert: IP Address Pool : Server is down -- SysInitCls::InitComplete failed Alert: IP Address Pool : Not Configured -- Task failed sanity check. Alert: IP Address Pool : No IP address available. -- No addresses in BOUND state. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Error
OBJECT-TYPE    
  DisplayString  

extLDAPServer 1.3.6.1.4.1.2505.1.2.9
Status of External LDAP Server. Possible Values: Warning: External LDAP Servers : Server is down Alert: External LDAP Servers : Server is down The values have the following meaning: Warning: External LDAP Servers : Server is down -- One server is down Alert: External LDAP Servers : Server is down -- All servers are down
OBJECT-TYPE    
  DisplayString  

radiusAuthServer 1.3.6.1.4.1.2505.1.2.10
Status of Radius Authentication Server. Possible Values: Warning: RADIUS Authentication Servers : Error Alert: RADIUS Authentication Servers : Error The values have the following meaning: Warning: RADIUS Authentication Servers : Error -- At least one server is available Alert: RADIUS Authentication Servers : Error -- No servers are available
OBJECT-TYPE    
  DisplayString  

certificateServer 1.3.6.1.4.1.2505.1.2.11
Status of Certificates Validity. Possible Values: Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;
OBJECT-TYPE    
  DisplayString  

extLDAPAuthServer 1.3.6.1.4.1.2505.1.2.12
Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
OBJECT-TYPE    
  DisplayString  

cmpServer 1.3.6.1.4.1.2505.1.2.13
Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;
OBJECT-TYPE    
  DisplayString  

radiusAcctServerTrap 1.3.6.1.4.1.2505.1.2.3001
Status of External Radius Accounting Server
TRAP-TYPE    
  severityLevel  
  radiusAcctServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

backupServerTrap 1.3.6.1.4.1.2505.1.2.3002
Status of External Disk Backup Server
TRAP-TYPE    
  severityLevel  
  backupServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

diskRedundencyTrap 1.3.6.1.4.1.2505.1.2.3003
Status of Local Disk Redundency
TRAP-TYPE    
  severityLevel  
  diskRedundency  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

intLDAPServerTrap 1.3.6.1.4.1.2505.1.2.3004
Status of Internal LDAP Server
TRAP-TYPE    
  severityLevel  
  intLDAPServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

loadBalancingServerTrap 1.3.6.1.4.1.2505.1.2.3005
Status of Load Balancing Server
TRAP-TYPE    
  severityLevel  
  loadBalancingServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

dnsServerTrap 1.3.6.1.4.1.2505.1.2.3006
Status of DNS Server
TRAP-TYPE    
  severityLevel  
  dnsServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

snmpServerTrap 1.3.6.1.4.1.2505.1.2.3007
Status of SNMP Server
TRAP-TYPE    
  severityLevel  
  snmpServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

ipAddressPoolTrap 1.3.6.1.4.1.2505.1.2.3008
Status of the IP address pool
TRAP-TYPE    
  severityLevel  
  ipAddressPool  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

extLDAPServerTrap 1.3.6.1.4.1.2505.1.2.3009
Status of External LDAP Server
TRAP-TYPE    
  severityLevel  
  extLDAPServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

radiusAuthServerTrap 1.3.6.1.4.1.2505.1.2.30010
Status of Radius Authentication Server
TRAP-TYPE    
  severityLevel  
  radiusAuthServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

certificateServerTrap 1.3.6.1.4.1.2505.1.2.30011
Status of Certificates Validity Possible Values: Healthy: Certificates Validity: Operational; Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;
TRAP-TYPE    
  severityLevel  
  certificateServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

extLDAPAuthServerTrap 1.3.6.1.4.1.2505.1.2.30012
Status of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
TRAP-TYPE    
  severityLevel  
  certificateServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

cmpServerTrap 1.3.6.1.4.1.2505.1.2.30013
Status of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;
TRAP-TYPE    
  severityLevel  
  cmpServer  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

serviceCESTrapInfo 1.3.6.1.4.1.2505.1.3
OBJECT IDENTIFIER    

netBuffers 1.3.6.1.4.1.2505.1.3.1
Network buffer usage. Possible Values: Warning: Buffer Usage : Utilization exceeds 75% Alert: Buffer Usage : Utilization exceeds 87.5%
OBJECT-TYPE    
  DisplayString  

fireWall 1.3.6.1.4.1.2505.1.3.2
Status of internal firewall. Possible Values: Disabled: Firewall: Firewall disabled; Disabled: Firewall: Firewall stopped; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; Warning: Firewall: Firewall state is not known!; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended; The values have the following meaning: -- The first two possible values are common to all firewalls. Disabled: Firewall: Firewall disabled; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; -- The firewall type (Contivity / CheckPoint) has been change, but for it -- to take effect, the Contivity must be restarted. -- Contivity Firewall specific values. Warning: Firewall: Firewall state is not known!; -- The Contivity firewall's -- state cannot be determined. -- CheckPoint Firewall specific values. Disabled: Firewall: Firewall stopped; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended;
OBJECT-TYPE    
  DisplayString  

fipsStatus 1.3.6.1.4.1.2505.1.3.3
Status of FIPS. Possible Values: Warning: FIPS: Random generator test failed; Warning: FIPS: DESMAC check on executables Failed; Warning: FIPS: DES KAT Test Failed; Warning: FIPS: SHA1 Self Test Failed; Alert: FIPS: status not known;
OBJECT-TYPE    
  DisplayString  

licensingStatus 1.3.6.1.4.1.2505.1.3.4
Status of temporary SW Licenses. Possible Values: Warning: Licensing: Temporary key will expire within 5 days; Alert: Licensing: Temporary key has expired;
OBJECT-TYPE    
  DisplayString  

natStatus 1.3.6.1.4.1.2505.1.3.5
Status of Network Address Translator. Possible Values: Disabled: NAT: NAT disabled; Warning: NAT: Reboot is required to start Interface NAT; Warning: NAT: NAT state is not known!; Alert: NAT: All Addresses in the Address Translation pool are used; Alert: NAT: LDAP policy parse failed - Using system default policy; The values have the following meaning: -- The first two possible values are common to all firewalls. Disabled: NAT: NAT disabled; Existing NAT sessions are not deleted, but -- no new address bindings are created for Interface NAT. Branch Office NAT -- is not affected. Warning: NAT: Reboot is required to start Interface NAT; -- To take effect, the Contivity must be restarted.
OBJECT-TYPE    
  DisplayString  

netBuffersTrap 1.3.6.1.4.1.2505.1.3.5001
Network buffer usage
TRAP-TYPE    
  severityLevel  
  netBuffers  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fireWallTrap 1.3.6.1.4.1.2505.1.3.5002
Status of internal firewall
TRAP-TYPE    
  severityLevel  
  fireWall  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

fipsStatusTrap 1.3.6.1.4.1.2505.1.3.5003
Status of FIPS
TRAP-TYPE    
  severityLevel  
  fipsStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

licensingStatusTrap 1.3.6.1.4.1.2505.1.3.5004
Status temporary SW Licenses
TRAP-TYPE    
  severityLevel  
  licensingStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

natStatusTrap 1.3.6.1.4.1.2505.1.3.5005
Status of Network Address Translator
TRAP-TYPE    
  severityLevel  
  natStatus  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

loginCESTrapInfo 1.3.6.1.4.1.2505.1.4
OBJECT IDENTIFIER    

failedLogin 1.3.6.1.4.1.2505.1.4.1
Failed Login Attempt. Possible Values: Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ; Failed Login Attempt: Username=(userid): Date/Time=(xx) ; Failed Login Attempt. Invalid Account: Username=(userid): Date/Time=(xx) ; Failed Remote Network Login: Username=(userid): Date/Time=(xx) ; Failed Remote Application Login: Username=(userid): Date/Time=(xx) ; The values have the following meaning: --(userid) is a place holder for the actual userid of the person or branch office --trying to login. --(xx) is a place holder for the date and time string.
OBJECT-TYPE    
  DisplayString  

failedLoginTrap 1.3.6.1.4.1.2505.1.4.101
Failed Login Attempt
TRAP-TYPE    
  severityLevel  
  failedLogin  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

intrusionCESTrapInfo 1.3.6.1.4.1.2505.1.5
OBJECT IDENTIFIER    

securityIntrusion 1.3.6.1.4.1.2505.1.5.1
Security Intrusion. Possible Values: Intruder: : Source: %s, Destination: %s;
OBJECT-TYPE    
  DisplayString  

securityIntrusionTrap 1.3.6.1.4.1.2505.1.5.201
Security Intrusion
TRAP-TYPE    
  severityLevel  
  securityIntrusion  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

powerUpTrap 1.3.6.1.4.1.2505.1.6
Power Up. Possible Values: Cold Start
OBJECT-TYPE    
  DisplayString  

severityLevel 1.3.6.1.4.1.2505.1.7
Severity of specific trap.
OBJECT-TYPE    
  INTEGER alert(1), warning(2), disabled(3), healthy(4), unknown(5)  

systemName 1.3.6.1.4.1.2505.1.8
System Name.
OBJECT-TYPE    
  DisplayString  

systemDate 1.3.6.1.4.1.2505.1.9
System Date.
OBJECT-TYPE    
  DisplayString  

systemTime 1.3.6.1.4.1.2505.1.10
System Time.
OBJECT-TYPE    
  DisplayString  

systemUpTime 1.3.6.1.4.1.2505.1.11
System Up Time.
OBJECT-TYPE    
  DisplayString  

periodicHeartbeat 1.3.6.1.4.1.2505.1.12
Periodic Heartbeat. Possible Values: Has been executed n times
OBJECT-TYPE    
  DisplayString  

snmpAgentTrapInfo-ces 1.3.6.1.4.1.2505.1.14
OBJECT IDENTIFIER    

snmpAgentAuthTrapInfo-ces 1.3.6.1.4.1.2505.1.14.1
OBJECT IDENTIFIER    

snmpAuthenOperation-ces 1.3.6.1.4.1.2505.1.14.1.1
SNMP operation attempted.
OBJECT-TYPE    
  INTEGER getRequest(160), getNextRequest(161), setRequest(163), getBulkRequest(165)  

snmpAuthenIpAddress-ces 1.3.6.1.4.1.2505.1.14.1.2
IP address of host trying to access the CES.
OBJECT-TYPE    
  IpAddress  

snmpAuthenCommString-ces 1.3.6.1.4.1.2505.1.14.1.3
Community string used to access the CES.
OBJECT-TYPE    
  DisplayString  

snmpAgentInterfaceInfo-ces 1.3.6.1.4.1.2505.1.14.2
OBJECT IDENTIFIER    

ifReasonForStatus-ces 1.3.6.1.4.1.2505.1.14.2.1
The reason for the status change. These include: unknown(1) -- the reason could not be determined. timed-out(2) -- connection(tunnel) timed out.
OBJECT-TYPE    
  IfReasonForStatus-ces  

ifPhysLocation-ces 1.3.6.1.4.1.2505.1.14.2.2
The physical location of the port. This has the values of motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5.
OBJECT-TYPE    
  PortLocation-ces  

ifPhysRelPos-ces 1.3.6.1.4.1.2505.1.14.2.3
The relative position of the physical port at the location defined by interfacePhysLocation.
OBJECT-TYPE    
  INTEGER  

ifIpAddr-ces 1.3.6.1.4.1.2505.1.14.2.4
For physical ports this is the associated IP address. For a tunnel connection it is the local IP address.
OBJECT-TYPE    
  IpAddress  

ifName-ces 1.3.6.1.4.1.2505.1.14.2.5
The name of the interface, same as ifName.
OBJECT-TYPE    
  DisplayString  

ifTunnelRemoteIpAddr-ces 1.3.6.1.4.1.2505.1.14.2.6
The remote IP address of a tunnel connection.
OBJECT-TYPE    
  IpAddress  

snmpAgentFirewallInfo-ces 1.3.6.1.4.1.2505.1.14.3
OBJECT IDENTIFIER    

firewallPolicyType-ces 1.3.6.1.4.1.2505.1.14.3.1
Policy type.
OBJECT-TYPE    
  FirewallPolicyType-ces  

firewallRuleTriggeredTrap 1.3.6.1.4.1.2505.1.14.3.1
An event sent at the user's request to signal that a rule has been matched. firewallPolicyType-ces -- Policy type. firewallRuleType-ces -- Type of rule that triggered this event. firewallRuleNumber-ces -- Number of the rule that triggered this event. ifIndex -- ifIndex is the index into the ifTable for port that received the packet. ifName-ces -- The name of the interface, same as ifName. firewallSrcAddr-ces -- Source IP address of the packet. firewallSrcPort-ces -- Source port address of the packet. firewallDestAddr-ces -- Destination IP address of the packet. firewallDestPort-ces -- Destination port of the packet. firewallProtocolID-ces -- The value of the protocol field in the IP header. firewallRuleAction-ces -- Action defined for the triggered rule.
TRAP-TYPE    
  firewallPolicyType-ces  
  firewallRuleType-ces  
  firewallRuleNumber-ces  
  ifIndex  
  ifName-ces  
  firewallSrcAddr-ces  
  firewallSrcPort-ces  
  firewallDestAddr-ces  
  firewallDestPort-ces  
  firewallProtocolID-ces  
  firewallRuleAction-ces  
  sysObjectID  
  sysName  

firewallRuleType-ces 1.3.6.1.4.1.2505.1.14.3.2
Type of rule that triggered this event.
OBJECT-TYPE    
  FirewallRuleType-ces  

firewallRuleNumber-ces 1.3.6.1.4.1.2505.1.14.3.3
Number of the rule that triggered this event.
OBJECT-TYPE    
  INTEGER  

firewallSrcAddr-ces 1.3.6.1.4.1.2505.1.14.3.6
Source IP address of the packet.
OBJECT-TYPE    
  IpAddress  

firewallSrcPort-ces 1.3.6.1.4.1.2505.1.14.3.7
Source port address of the packet.
OBJECT-TYPE    
  INTEGER  

firewallDestAddr-ces 1.3.6.1.4.1.2505.1.14.3.8
Destination IP address of the packet.
OBJECT-TYPE    
  IpAddress  

firewallDestPort-ces 1.3.6.1.4.1.2505.1.14.3.9
Destination port of the packet.
OBJECT-TYPE    
  INTEGER  

firewallProtocolID-ces 1.3.6.1.4.1.2505.1.14.3.10
The value of the protocol field in the IP header.
OBJECT-TYPE    
  INTEGER  

firewallRuleAction-ces 1.3.6.1.4.1.2505.1.14.3.11
Action defined for the triggered rule.
OBJECT-TYPE    
  FirewallRuleAction-ces  

powerUpTrapEntry 1.3.6.1.4.1.2505.1.401
Power Up
TRAP-TYPE    
  severityLevel  
  powerUpTrap  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

periodicHeartbeatTrap 1.3.6.1.4.1.2505.1.601
Periodic Heartbeat
TRAP-TYPE    
  severityLevel  
  periodicHeartbeat  
  systemName  
  systemDate  
  systemTime  
  systemUpTime  

Defined Objects

PortLocation-ces  
INTEGER motherBoardOrSlot0(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6)    

IfReasonForStatus-ces  
INTEGER unknown(1), idle-time-out(2), ip-addr-chg(3), no-response(4), user-interaction(5), time-limit(6), testing(7), test-complete-success(8), test-complete-failure(9), link-down(10), link-up(11)    

FirewallPolicyType-ces  
INTEGER firewall(1), nat(2)    

FirewallRuleType-ces  
INTEGER over-ride(1), sourceInterface(2), destinationInterface(3), default(4)    

FirewallRuleAction-ces  
INTEGER unknown(1), allow(2), reject(3), drop(4)