CTRON-SSR-TRAP-MIB-V1
File:
CTRON-SSR-TRAP-MIB-V1.mib (5437 bytes)
Imported modules
Imported symbols
Defined Objects
| envPowerSupplyFailed |
1.3.6.1.4.1.52.2501.10.1 |
| A power supply on the sending device has failed. The sysHwPowerSupply object identifies the failed supply. Poll sysHwPowerSupply to obtain current status of power supplies |
| TRAP-TYPE |
|
|
|
| |
sysHwPowerSupply |
|
|
| envPowerSupplyRecovered |
1.3.6.1.4.1.52.2501.10.2 |
| A power supply on the sending device has recovered after failure. The sysHwPowerSupply object identifies the recovered supply. Poll sysHwPowerSupply to obtain current status of power supplies |
| TRAP-TYPE |
|
|
|
| |
sysHwPowerSupply |
|
|
| envFanFailed |
1.3.6.1.4.1.52.2501.10.3 |
| A Fan tray on the sending device has failed. The sysHwFan object identifies the failed fan tray. Poll sysHwFan to obtain current status. |
| TRAP-TYPE |
|
|
|
| |
sysHwFan |
|
|
| envFanRecovered |
1.3.6.1.4.1.52.2501.10.4 |
| A Fan tray on the sending device has recovered after failure. The sysHwFan object identifies the recovered Fan tray. Poll sysHwFan to obtain current status. |
| TRAP-TYPE |
|
|
|
| |
sysHwFan |
|
|
| envTempExceeded |
1.3.6.1.4.1.52.2501.10.5 |
| A temperature inside the chassis on the sending device has exceeded normal operating temperature. The sysHwTemperature object identifies the current status. Poll sysHwTemperature to obtain current status. |
| TRAP-TYPE |
|
|
|
| |
sysHwTemperature |
|
|
| envTempNormal |
1.3.6.1.4.1.52.2501.10.6 |
| A temperature inside the chassis on the sending device has returned to normal operating temperature. The sysHwTemperature object identifies the current status. Poll sysHwTemperature to obtain current status. |
| TRAP-TYPE |
|
|
|
| |
sysHwTemperature |
|
|
| envHotSwapIn |
1.3.6.1.4.1.52.2501.10.7 |
| A module has been inserted into the chassis. sysHwModuleSlotNumber identifies the slot the module was inserted into. Poll sysHwLastHotSwapEvent to monitor hotswap events. |
| TRAP-TYPE |
|
|
|
| |
sysHwModuleSlotNumber |
|
|
| envHotSwapOut |
1.3.6.1.4.1.52.2501.10.8 |
| A module has been turned off or removed from the chassis. sysHwModuleSlotNumber identifies the slot the module was removed from. Poll sysHwLastHotSwapEvent to monitor hotswap events. |
| TRAP-TYPE |
|
|
|
| |
sysHwModuleSlotNumber |
|
|
| envBackupControlModuleOnline |
1.3.6.1.4.1.52.2501.10.9 |
| A backup control module that was in standby mode has taken over for a failed primary control module. Poll sysHwControlModuleBackupState for current state of backup control module. sysHwModuleSlotNumber is the index into the sysHwModuleTable for the now active control module. |
| TRAP-TYPE |
|
|
|
| |
sysHwModuleSlotNumber |
|
|