CTRON-SSR-TRAP-MIB-V1

File: CTRON-SSR-TRAP-MIB-V1.mib (5437 bytes)

Imported modules

RFC-1215 CTRON-SSR-SMI-MIB CTRON-SSR-HARDWARE-MIB

Imported symbols

TRAP-TYPE ssrTraps sysHwPowerSupply
sysHwFan sysHwTemperature sysHwModuleSlotNumber

Defined Objects

envPowerSupplyFailed 1.3.6.1.4.1.52.2501.10.1
A power supply on the sending device has failed. The sysHwPowerSupply object identifies the failed supply. Poll sysHwPowerSupply to obtain current status of power supplies
TRAP-TYPE    
  sysHwPowerSupply  

envPowerSupplyRecovered 1.3.6.1.4.1.52.2501.10.2
A power supply on the sending device has recovered after failure. The sysHwPowerSupply object identifies the recovered supply. Poll sysHwPowerSupply to obtain current status of power supplies
TRAP-TYPE    
  sysHwPowerSupply  

envFanFailed 1.3.6.1.4.1.52.2501.10.3
A Fan tray on the sending device has failed. The sysHwFan object identifies the failed fan tray. Poll sysHwFan to obtain current status.
TRAP-TYPE    
  sysHwFan  

envFanRecovered 1.3.6.1.4.1.52.2501.10.4
A Fan tray on the sending device has recovered after failure. The sysHwFan object identifies the recovered Fan tray. Poll sysHwFan to obtain current status.
TRAP-TYPE    
  sysHwFan  

envTempExceeded 1.3.6.1.4.1.52.2501.10.5
A temperature inside the chassis on the sending device has exceeded normal operating temperature. The sysHwTemperature object identifies the current status. Poll sysHwTemperature to obtain current status.
TRAP-TYPE    
  sysHwTemperature  

envTempNormal 1.3.6.1.4.1.52.2501.10.6
A temperature inside the chassis on the sending device has returned to normal operating temperature. The sysHwTemperature object identifies the current status. Poll sysHwTemperature to obtain current status.
TRAP-TYPE    
  sysHwTemperature  

envHotSwapIn 1.3.6.1.4.1.52.2501.10.7
A module has been inserted into the chassis. sysHwModuleSlotNumber identifies the slot the module was inserted into. Poll sysHwLastHotSwapEvent to monitor hotswap events.
TRAP-TYPE    
  sysHwModuleSlotNumber  

envHotSwapOut 1.3.6.1.4.1.52.2501.10.8
A module has been turned off or removed from the chassis. sysHwModuleSlotNumber identifies the slot the module was removed from. Poll sysHwLastHotSwapEvent to monitor hotswap events.
TRAP-TYPE    
  sysHwModuleSlotNumber  

envBackupControlModuleOnline 1.3.6.1.4.1.52.2501.10.9
A backup control module that was in standby mode has taken over for a failed primary control module. Poll sysHwControlModuleBackupState for current state of backup control module. sysHwModuleSlotNumber is the index into the sysHwModuleTable for the now active control module.
TRAP-TYPE    
  sysHwModuleSlotNumber