CXMCVOX-MIB

File: CXMCVOX-MIB.mib (295487 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
CXProduct-SMI CXModuleHardware-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
cxMc600 cxModuleHwPhysSlot

Defined Objects

cxMcVox 1.3.6.1.4.1.495.2.1.1.2
OBJECT IDENTIFIER    

cxMcVoxGlobal 1.3.6.1.4.1.495.2.1.1.2.1
OBJECT IDENTIFIER    

cxMcVoxTrapStatus 1.3.6.1.4.1.495.2.1.1.2.1
Reports that there is a change in the functional state of the voice channel. cxMcVoxTrapStatus = 1 if the port is disabled cxMcVoxTrapStatus = 2 if the port is enabled cxMcVoxTrapStatus = 3 if there is no I/O hardware
TRAP-TYPE    
  cxModuleHwPhysSlot  
  cxMcVoxStatusCardNumber  
  cxMcVoxStatusPortNumber  
  cxMcVoxStatusPortStatus  

cxMcVoxGlobalAdmPathLng 1.3.6.1.4.1.495.2.1.1.2.1.1
obsolete. The ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
OBJECT-TYPE    
  INTEGER 2..4  

cxMcVoxGlobalReinitPath 1.3.6.1.4.1.495.2.1.1.2.1.2
The ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalClearPath 1.3.6.1.4.1.495.2.1.1.2.1.3
Path ID no longer exists with the new voice routing scheme Determines whether to restore all administrative Path IDs to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative Path IDs will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Change: administrative (Voice Routing or VR).
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalReinitNet 1.3.6.1.4.1.495.2.1.1.2.1.4
The ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalClearNet 1.3.6.1.4.1.495.2.1.1.2.1.5
Network ID no longer exists in the new voice routing scheme (Voice Routing or VR). Determines whether to restore all administrative routing entries (i.e. network routing entries, Path IDs and Group IDs) to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative routing entries will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalAdmLocalId 1.3.6.1.4.1.495.2.1.1.2.1.6
Determines the administrative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxGlobalOpeLocalId 1.3.6.1.4.1.495.2.1.1.2.1.7
Displays the operative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxGlobalAdmLocalId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxGlobalTensionRing 1.3.6.1.4.1.495.2.1.1.2.1.8
Displays the state of the ring generator power supply. The power supply resides on the ring generator card located on the voice I/O card. You cannot modify this object. Options: down (1) up (2) Default Value: none
OBJECT-TYPE    
  INTEGER down(1), up(2)  

cxMcVoxGlobalTensionDc 1.3.6.1.4.1.495.2.1.1.2.1.9
Displays the state of the DC power supply on the voice I/O card. Options: down (1): The DC power supply on the voice I/O card is down. up (2):The DC power supply on the voice I/O card is up. Default Value: none
OBJECT-TYPE    
  INTEGER down(1), up(2)  

cxMcVoxGlobalTrapRing 1.3.6.1.4.1.495.2.1.1.2.1.10
Determines if the ring generator power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the ring generator power supply. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management console each time a change occurs in the functional state (i.e., up or down) of the ring generator power supply. Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxGlobalTrapDc 1.3.6.1.4.1.495.2.1.1.2.1.11
Determines if the DC power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the DC power supply. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management consoleto each time a change occurs in the functional state (i.e., up or down) of the voice I/O card DC power supply. Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxGlobalAdmGrpNbPoll 1.3.6.1.4.1.495.2.1.1.2.1.12
The maximum number of remote voice station(s) that the the local voice station polls within a single call request has been moved from the Global Parameters group to the Group ID Entries group. Determines the maximum number of remote voice stations that the local voice station polls with a single call request. Note: This object is only relevant if at least one Group ID has been defined using the objects in the cxMcVox Administrative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..20  

cxMcVoxGlobalOpeGrpNbPoll 1.3.6.1.4.1.495.2.1.1.2.1.13
The the maximum number of remote voice stations the local voice station polls with a single call request. has been moved from the Global Parameters group to the Group ID Entries group. Displays the maximum number of remote voice stations the local voice station polls with a single call request. Note: This object is only relevant if at least one Group ID has been defined with the objects in the cxMcVox Administrative Grp Group Table. You cannot modify this object. If you want to change this value you must modify the object cxMcVoxGlobalAdmNbPoll (of this table). Range of Values: 1 to 20 Default Value: 4
OBJECT-TYPE    
  INTEGER 1..20  

cxMcVoxGlobalClearGrp 1.3.6.1.4.1.495.2.1.1.2.1.14
Determines whether to restore all administrative Group IDs to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative Group IDs will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalOpePathLng 1.3.6.1.4.1.495.2.1.1.2.1.15
The Operational Path Length commands are now in the Operational Path table.
OBJECT-TYPE    
  INTEGER 2..4  

cxMcVoxGlobalReinitRouting 1.3.6.1.4.1.495.2.1.1.2.1.16
Triggers the reinitialization of the operative routing table. The setting of this object is dynamic. When set to 'yes', all administrative routing, path and group entries will be written to the operative routing table (i.e. will be in the active global configuration). Options: no (1) yes (2) Default Value: no (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalForceDefConfig 1.3.6.1.4.1.495.2.1.1.2.1.17
Determines whether the default factory configuration will replace both the administrative and operative configurations. The setting of this object is dynamic. When set to 'yes', this object triggers the immediate reconfiguration of all objects to the default factory settings. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalReinitPinTable 1.3.6.1.4.1.495.2.1.1.2.1.18
Saves the PIN table configuration in non-volatile memory, but only enables it if the object cxMcVoxGlobalAdmEnablePinTable is set to 'yes'. Options: no (1) yes (2) Default Value: no (1)
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalAdmEnablePinTable 1.3.6.1.4.1.495.2.1.1.2.1.19
Specifies whether the voice station verifies PIN (Personal Identification Numbers) codes before allowing a connection to be established. Options: no (1) yes (2) Default Value: no (1)
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalOpeEnablePinTable 1.3.6.1.4.1.495.2.1.1.2.1.20
Displays the operational state of PIN verification. Options: no (1) yes (2) Default Value: no (1)
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalReinitCodesTable 1.3.6.1.4.1.495.2.1.1.2.1.21
Copy the planned zone code configuration table into active zone code table (non-volatile memory). Options: no (1) yes (2) Default Value: no (1)
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalAdmEnableCodesTable 1.3.6.1.4.1.495.2.1.1.2.1.22
The CX900 does not currently support this object. Specifies whether the voice station verifies incoming telephone codes against its internal remote translation table. Options: no (1) yes (2) Default Value: no (1)
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalOpeEnableCodesTable 1.3.6.1.4.1.495.2.1.1.2.1.23
The CX900 does not currently support this object. Displays the operational state of the remote translation table. Options: no (1) yes (2) Default Value: none
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalSoftRev 1.3.6.1.4.1.495.2.1.1.2.1.24
Displays the software revision of the local voice station . You cannot modify this object. It is a display that the software provides. Range of Values: a maximum of 30 alphanumeric characters Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

cxMcVoxGlobalGlmInBetwReqTime 1.3.6.1.4.1.495.2.1.1.2.1.100
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 2000 Default Value: 500
OBJECT-TYPE    
  INTEGER 10..2000  

cxMcVoxGlobalGlmMaxTimeToTxReq 1.3.6.1.4.1.495.2.1.1.2.1.101
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500
OBJECT-TYPE    
  INTEGER 10..20000  

cxMcVoxGlobalGlmInBetwRespTime 1.3.6.1.4.1.495.2.1.1.2.1.102
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 500
OBJECT-TYPE    
  INTEGER 10..2000  

cxMcVoxGlobalGlmMaxTimeToTxResp 1.3.6.1.4.1.495.2.1.1.2.1.103
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500
OBJECT-TYPE    
  INTEGER 10..20000  

cxMcVoxGlobalGlmVoiceSilenceTime 1.3.6.1.4.1.495.2.1.1.2.1.104
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 100 to 60000 Default Value: 3000
OBJECT-TYPE    
  INTEGER 100..60000  

cxMcVoxGlobalGlmSupervSilenceTime 1.3.6.1.4.1.495.2.1.1.2.1.105
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1000 to 60000 Default Value: 3000
OBJECT-TYPE    
  INTEGER 1000..60000  

cxMcVoxGlobalGsdAutoCnctDelay 1.3.6.1.4.1.495.2.1.1.2.1.106
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1 to 20000 Default Value: 1
OBJECT-TYPE    
  INTEGER 1..20000  

cxMcVoxGlobalClearLclExt 1.3.6.1.4.1.495.2.1.1.2.1.107
Clears Local Extensions after the next Reset. Planned Local Extensions are cleared immediately. Options: no (1): Local Extensions are not cleared. yes (2): Local Extensions are cleared. Default Value: no (1) Configuration Change: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalClearRmtExt 1.3.6.1.4.1.495.2.1.1.2.1.108
Clears Remote Extensions after the next Reset. Planned Remote Extensions are cleared immediately. Options: no (1): Remote Extensions are not cleared. yes (2): Remote Extensions are cleared Default Value: no (1) Configuration Change: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxGlobalWanSlot 1.3.6.1.4.1.495.2.1.1.2.1.109
Determines the slot number of the FR600 card that is performing Voice Routing with the new Voice Routing scheme. Range of Values: 1 to 16 Default Value: 1
OBJECT-TYPE    
  INTEGER 1..16  

cxMcVoxGlobalNetNbDigits 1.3.6.1.4.1.495.2.1.1.2.1.110
Determines the number of digits used to represent Local Extensions, Remote Extensions and Remote Extension group IDs. Range of Values: 1 to 4 Default Value: 3
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxMibLevel 1.3.6.1.4.1.495.2.1.1.2.1.111
Used to determine current MIB module release supported by the agent. Object is in decimal.
OBJECT-TYPE    
  INTEGER  

cxMcVoxGlobalRecogAcc 1.3.6.1.4.1.495.2.1.1.2.1.112
This specifies whether to recognize the defined Access Code. With the option enabled, if the Access Code is recognized, it is stripped from the dialing digit flow and then the remaining digits are interpreted as the code that has been really dialed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxGlobalAccCode 1.3.6.1.4.1.495.2.1.1.2.1.113
Determines the numeric code to access the international network. Range of Values: 1 to 5 numeric digits Default Value: 011 Configuration Changed: operational
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxGlobalAccCodeLng 1.3.6.1.4.1.495.2.1.1.2.1.114
Determines the number of digits in the configured Access Code.
OBJECT-TYPE    
  INTEGER  

cxMcVoxGlobalAdmPinCodeLng 1.3.6.1.4.1.495.2.1.1.2.1.115
Determines the administrative number of digits in all Personal Identification Numbers (PINs).
OBJECT-TYPE    
  INTEGER  

cxMcVoxGlobalOpePinCodeLng 1.3.6.1.4.1.495.2.1.1.2.1.116
Determines the operational number of digits in all Personal Identification Numbers (PINs).
OBJECT-TYPE    
  INTEGER  

cxMcVoxGlobalClearHistoryTable 1.3.6.1.4.1.495.2.1.1.2.1.117
Determines whether to clear ALL logging information from the history table. Options: disable(1): No action enable(2): Clear history table completely
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxGlobalHistoryMaxNumberOfEntries 1.3.6.1.4.1.495.2.1.1.2.1.118
The maximum number of entries in the history table.
OBJECT-TYPE    
  INTEGER 20..256  

cxMcVoxGlobalHistoryPercentageFull 1.3.6.1.4.1.495.2.1.1.2.1.119
The percentage of the history table that must be filled before a trap is sent to the management station.
OBJECT-TYPE    
  INTEGER 0..95  

cxMcVoxGlobalTrapHistory 1.3.6.1.4.1.495.2.1.1.2.1.120
Determines if the call history trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the call history trap. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management console each time a change occurs in the functional state (i.e., up or down) of the ring generator power supply. Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxGlobalLseTimerT2 1.3.6.1.4.1.495.2.1.1.2.1.121
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 500
OBJECT-TYPE    
  INTEGER 0..65535  

cxMcVoxGlobalLseTimerT3 1.3.6.1.4.1.495.2.1.1.2.1.122
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 550
OBJECT-TYPE    
  INTEGER 0..65535  

cxMcVoxGlobalExtBitMask 1.3.6.1.4.1.495.2.1.1.2.1.123
This object is a bitmap that selects up to cxMcVoxGlobalNetNbDigits, which can be set up to 4 digits, corresponding to a bit that is set. The default value corresponds to 7 (or 00000111 in binary). Range of Values: 0 to 255 Default Value: 7
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxCfgTable 1.3.6.1.4.1.495.2.1.1.2.2
Voice station configuration Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxCfgEntry

cxMcVoxTrapRing 1.3.6.1.4.1.495.2.1.1.2.2
Reports that there is a change in the functional state of the ring generator power supply. cxMcVoxTrapRing = 2 if the ringing generator is good cxMcVoxTrapRing = 1 otherwise
TRAP-TYPE    
  cxModuleHwPhysSlot  
  cxMcVoxGlobalTensionRing  

cxMcVoxCfgEntry 1.3.6.1.4.1.495.2.1.1.2.2.1
Voice station configuration row definition.
OBJECT-TYPE    
  CxMcVoxCfgEntry  

cxMcVoxCfgCardIndex 1.3.6.1.4.1.495.2.1.1.2.2.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default Value: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxCfgPortIndex 1.3.6.1.4.1.495.2.1.1.2.2.1.2
Displays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxCfgDriverAdmUsed 1.3.6.1.4.1.495.2.1.1.2.2.1.3
Determines the administrative driver of the port. The driver controls which signals the port supports. A port can only support one type of driver at any one time. Depending on the type of driver you choose, you must perform further configuration using one of the following tables: - cxMcVoxEmAdmtable (for E&M drivers) - cxMcVoxFxsAdmTable (for FXS drivers) - cxMcVoxFxoAdmTable (for FXO drivers) Options: em (1): Recommended for a PBX connection. Provides RJ-12 and PB-45 port connectors. fxs (2): Recommended for a standard telephone connection, where the Memotec device simulates a Telco. The device provides the ring and dial tone. FXS can also be used for a PBX connection, and provides an RJ-12 port connector. fxo (3): Recommended for a standard telephone connection, where the Memotec device simulates a telephone. FXO can also be used for a PBX connection, and provides an RJ-12 port connector. Default Value: fxs (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER em(1), fxs(2), fxo(3)  

cxMcVoxCfgDriverOpeUsed 1.3.6.1.4.1.495.2.1.1.2.2.1.4
Displays the operative driver currently running on the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxCfgDriverAdmUsed (of this table). Options: em (1) fxs (2) fxo (3) Default Value: fxs (2)
OBJECT-TYPE    
  INTEGER em(1), fxs(2), fxo(3)  

cxMcVoxCfgTrapOnLine 1.3.6.1.4.1.495.2.1.1.2.2.1.5
Determines the state of the port's online trap. When set to 'enable', every time a fax or phone call begins (i.e. the port switches from online to offline), the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxCfgTrapOffLine 1.3.6.1.4.1.495.2.1.1.2.2.1.6
Determines the state of the port's offline trap. When set to 'enable', every time a fax or phone call ends ( i.e. the port switches from offline to online) the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxCfgTrapStatus 1.3.6.1.4.1.495.2.1.1.2.2.1.7
Determines the state of the port's status trap. When set to 'enable', every time the functional state of the voice channel changes (i.e. up or down) the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the voice channel. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxCfgTrapState 1.3.6.1.4.1.495.2.1.1.2.2.1.8
Determines the state of the port's outgoing calls trap. When set to 'enable', every time an outgoing call request is in process the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxCfgTestPort 1.3.6.1.4.1.495.2.1.1.2.2.1.9
Determines the state of the port's self test. When set to 'yes', this object triggers the port to intiate a self-test. The port examines various hardware components, for example the RAM, DPRAM and I/O access. Each test runs for less than 2 seconds. You can perform the test on either an open (call in progress) or closed channel. If you perform the test on an open channel the call that is in progress is disconnected. The user must place the call again after the test is complete. Note: The port must be set to 'enable' (using the object cxMcVoxEmAdmPortStatus, cxMcVoxFxoAdmstatus or cxMcVoxFxsAdmStatus) to be able to perform the self-test. You can view the results of the test in the cxMcVoxStatusTable. While the port is running a self-test, it is not functional. It will return to normal when the test is complete. The setting of this object is dynamic. When set to'yes' the port immediately begins to monitor itself. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxCfgToneTest 1.3.6.1.4.1.495.2.1.1.2.2.1.10
Determines the state of the port's standard tone test (1004Hz). When set to 'enable', this object triggers the port to perform a tone test. The port tests its voice sound quality by transmitting a 1004Hz tone. You can perform the test on either an open (call in progress) or closed channel. However, if you initiate the test on an open channel, the connection is not disrupted, but the local user will not be able to hear the remote user. The local user will only hear the tone the test generates. You must set this object to 'disable' to stop the test. It does not stop on its own. The setting of this object is dynamic. When set to'enable' the tone test begins immediately. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxCfgReinitPort 1.3.6.1.4.1.495.2.1.1.2.2.1.11
Determines the port's reinitialization state. The setting of this object is dynamic. When set to 'yes', this object triggers the port to write all administrative port configuration entries to the operative port configuration table (i.e. they will be in the active port configuration). Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxCfgClearPort 1.3.6.1.4.1.495.2.1.1.2.2.1.12
Determines whether to restore all administrative voice port configurations to the default factory settings. The setting of this object is dynamic. When set to 'yes' the configuration of the administrative voice port (as displays in the objects cxMcVoxCfgCardIndex and cxMcVoxCfgPortIndex) will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxCfgOpeAcelpRev 1.3.6.1.4.1.495.2.1.1.2.2.1.14
Displays the ACELP software revision currently running on the operative voice channel. Range of Values: 0 to 12 alphanumeric characters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: ACELP-2.BIN
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

cxMcVoxCfgCmdImmTest 1.3.6.1.4.1.495.2.1.1.2.2.1.15
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0
OBJECT-TYPE    
  INTEGER 0..4294967295  

cxMcVoxCfgCmdTest 1.3.6.1.4.1.495.2.1.1.2.2.1.16
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0
OBJECT-TYPE    
  INTEGER 0..4294967295  

cxMcVoxCfgMaxPktFrame 1.3.6.1.4.1.495.2.1.1.2.2.1.17
The number of voice packet included in a voice frame. Less voice packet there is in a frame, bigger is the bandwitdh overhead on the WAN link, but better is the voice path end-to-end delay. The best compromise is a size of two (2) voice packets per voice frame, which correpsond to the default value.
OBJECT-TYPE    
  INTEGER 1..3  

cxMcVoxCfgMaxSkew 1.3.6.1.4.1.495.2.1.1.2.2.1.18
The number of msec of skew that the end-to-end synchronization algorithm must compensate.
OBJECT-TYPE    
  INTEGER 25..125  

cxMcVoxStatAndLog 1.3.6.1.4.1.495.2.1.1.2.3
OBJECT IDENTIFIER    

cxMcVoxTrapDc 1.3.6.1.4.1.495.2.1.1.2.3
Reports that there is a change in the functional state of the DC power supply. cxMcVoxGlobalTensionDc = 2 if the DC power supply is good cxMcVoxGlobalTensionDc = 1 otherwise
TRAP-TYPE    
  cxModuleHwPhysSlot  
  cxMcVoxGlobalTensionDc  

cxMcVoxStatusTable 1.3.6.1.4.1.495.2.1.1.2.3.1
Voice station status table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxStatusEntry

cxMcVoxStatusEntry 1.3.6.1.4.1.495.2.1.1.2.3.1.1
Voice station status row definition.
OBJECT-TYPE    
  CxMcVoxStatusEntry  

cxMcVoxStatusCardNumber 1.3.6.1.4.1.495.2.1.1.2.3.1.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default Value: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxStatusPortNumber 1.3.6.1.4.1.495.2.1.1.2.3.1.1.2
Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxStatusPortStatus 1.3.6.1.4.1.495.2.1.1.2.3.1.1.3
Displays the functional status of the port. You cannot modify this object. It is a display that the software provides. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none
OBJECT-TYPE    
  INTEGER disable(1), enable(2), no-voice-io(3), boot-err-1(31), boot-err-2(32), boot-err-3(33), boot-err-4(34), appl-err-1(41), appl-err-2(42), appl-err-3(43), appl-err-4(44)  

cxMcVoxStatusHookLocal 1.3.6.1.4.1.495.2.1.1.2.3.1.1.4
Displays the state of the local port's ability to establish a connection. When the status shows 'on', the port is idle and ready to transmit. You cannot modify this object. It is a display that the software provides. Options: on (1): port is in the on-hook state and is able to establish a connection. off (2): port is in the off-hook state and cannot establish a connection.
OBJECT-TYPE    
  INTEGER on(1), off(2), unknown(3)  

cxMcVoxStatusHookRem 1.3.6.1.4.1.495.2.1.1.2.3.1.1.5
Displays the state of the remote port's ability to establish a connection. When the status shows 'on', the remote port is idle and ready to transmit. You cannot modify this object. It is a display that the software provides. Options: on (1): port is in the on-hook state and is able to establish a connection. off (2): port is in the off-hook state and cannot establish a connection. unknown (3)
OBJECT-TYPE    
  INTEGER on(1), off(2), unknown(3)  

cxMcVoxStatusIoAccess 1.3.6.1.4.1.495.2.1.1.2.3.1.1.6
Displays the results of the test that the CPU performs on the accessibility of the voice channel control registers residing on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the voice channel registers on the voice I/O card. Contact Memotec service personnel. passed (2): CPU is able to access the voice channel registers on the voice I/O card. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusChannelAccess 1.3.6.1.4.1.495.2.1.1.2.3.1.1.7
Displays the results of the test the CPU performs on the DPRAM. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the DPRAM. Contact Memotec service personnel. passed (2): CPU is able to access DPRAM. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusDspRam 1.3.6.1.4.1.495.2.1.1.2.3.1.1.8
Displays the results of the test the DSP performs on the accessibility of the RAM memory on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot access the RAM memory on the voice I/O card. Contact Memotec service personnel. passed (2): DSP is able to access RAM memory. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusDspDpram 1.3.6.1.4.1.495.2.1.1.2.3.1.1.9
Displays the results of the test the DSP performs on the voice I/O card's DPRAM memory. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot access the DPRAM memory on the voice I/O card. Contact Memotec service personnel. passed (2): DSP is able to access DPRAM memory on the voice I/O card. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusSamplingTime 1.3.6.1.4.1.495.2.1.1.2.3.1.1.10
Displays the results of the test the DSP performs on the sampling rate of a voice stream. The DSP tests that the sampling rate is done at 8KHz. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot test sampling rate. Contact Memotec service personnel. passed (2): DSP is able to test sampling rate and it is at 8KHz. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusWatchdog 1.3.6.1.4.1.495.2.1.1.2.3.1.1.11
Displays the results of the test the CPU performs on the watchdog timer which resides on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the watchdog timer. Contact Memotec service personnel. passed (2): CPU is able to access watchdog timer and it is performing properly. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none
OBJECT-TYPE    
  INTEGER fault(1), passed(2), inapplicable(3), running(4)  

cxMcVoxStatusRemPortStatus 1.3.6.1.4.1.495.2.1.1.2.3.1.1.12
Displays the channel number of the attached remote port. You cannot modify this object. Range of Values: 0-4294967295
OBJECT-TYPE    
  INTEGER 0..4294967295  

cxMcVoxStatusInputDbmLevel 1.3.6.1.4.1.495.2.1.1.2.3.1.1.13
Displays the current Dbm level of the input analog voice signal. You cannot modify this object. . Range of Values: 700 to 1050 (-30dBm to 5dBm) Default Value: none
OBJECT-TYPE    
  INTEGER 700..1050  

cxMcVoxStatusPhyIfType 1.3.6.1.4.1.495.2.1.1.2.3.1.1.14
OBJECT-TYPE    
  INTEGER if-em(1), if-fxs(2), if-fxo(3), if-absent(4), if-unknown(5)  

cxMcVoxStatusDspUtilization 1.3.6.1.4.1.495.2.1.1.2.3.1.1.100
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 1000 Default Value: none
OBJECT-TYPE    
  INTEGER 0..1000  

cxMcVoxStatusIOResetState 1.3.6.1.4.1.495.2.1.1.2.3.1.1.101
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: in-reset (1) normal (2) unknown (3)
OBJECT-TYPE    
  INTEGER in-reset(1), normal(2), unknown(3)  

cxMcVoxEventTable 1.3.6.1.4.1.495.2.1.1.2.3.2
OnLine/OffLine events table for incoming/outgoing calls.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxEventEntry

cxMcVoxEventEntry 1.3.6.1.4.1.495.2.1.1.2.3.2.1
Online/Offline events row definition.
OBJECT-TYPE    
  CxMcVoxEventEntry  

cxMcVoxEventCardNumber 1.3.6.1.4.1.495.2.1.1.2.3.2.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxEventPortNumber 1.3.6.1.4.1.495.2.1.1.2.3.2.1.2
Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: 1 or 2 Default Value: none
OBJECT-TYPE    
  INTEGER 1..2  

cxMcVoxEventLogIndex 1.3.6.1.4.1.495.2.1.1.2.3.2.1.3
Displays the index number of the event log. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxEventDateAndTimeOnLine 1.3.6.1.4.1.495.2.1.1.2.3.2.1.4
Displays the date and time of the last online event. An online event is any incoming or outgoing call that the voice station generates. The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week - 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(20..20)  

cxMcVoxEventDateAndTimeOffLine 1.3.6.1.4.1.495.2.1.1.2.3.2.1.5
Displays the date and time of the last offline event. An offline event is any incoming or outgoing call that the voice station terminates. The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week - 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(20..20)  

cxMcVoxEventPhoneNumber 1.3.6.1.4.1.495.2.1.1.2.3.2.1.6
Displays the phone number (including any voice mail digits) the user enters to reach a remote telephone or fax machine. This object is irrelevant for incoming calls. You cannot modify this object. Range of Values: 1 to 32 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

cxMcVoxEventLnkState 1.3.6.1.4.1.495.2.1.1.2.3.2.1.7
Displays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a remote chassis location that does not exist. remError (2): all voice ports at the specified remote are inactive and therefore cannot accept the call. It is possible that the remote ports are disabled or that the I/O card is not installed. busy (3): all voice ports at the specified remote are busy and therefore unavailable to accept the call. open (4): the call was successfully put through to a voice port at the remote location. errActiveChn (5): the end-user has replaced the receiver (on-hook) at the end of a call and then removed the receiver (off-hook) so quickly that the connection has not had sufficient time to completely disconnect. The end-user should wait a few seconds after replacing the receiver before attempting to place another call. errPath (6): the Path ID (dialing code) the user entered is not listed in the routing table. Check that the Path ID and routing are completely configured. errLnk (7): there is an error condition on the line between the local and remote link stations causing the link to be inactive. fixedLnkDown (8): Memotec use only. Contact Memotec service personnel if this value displays. fixedLnkUp (9): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none
OBJECT-TYPE    
  INTEGER remUnavailable(1), remError(2), busy(3), open(4), errActiveChn(5), errPath(6), errLnk(7), fixedLnkDown(8), fixedLnkUp(9)  

cxMcVoxEventPin 1.3.6.1.4.1.495.2.1.1.2.3.2.1.8
Displays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digits, each number from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(2..8)  

cxMcVoxEventClrEvts 1.3.6.1.4.1.495.2.1.1.2.3.2.1.9
Determines whether to clear ALL logging information from the Event group table. Options: no (1) yes (2) Default Value: no (1) Configuration Change: none
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxStateTable 1.3.6.1.4.1.495.2.1.1.2.3.3
Connections table for outgoing calls.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxStateEntry

cxMcVoxStateEntry 1.3.6.1.4.1.495.2.1.1.2.3.3.1
Outgoing call connection state row definition.
OBJECT-TYPE    
  CxMcVoxStateEntry  

cxMcVoxStateCardNumber 1.3.6.1.4.1.495.2.1.1.2.3.3.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxStatePortNumber 1.3.6.1.4.1.495.2.1.1.2.3.3.1.2
Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card on has 1 port. CX1000: 1 or 2 Default Value: none
OBJECT-TYPE    
  INTEGER 1..2  

cxMcVoxStateLogIndex 1.3.6.1.4.1.495.2.1.1.2.3.3.1.3
Displays the number of the table row containing objects used for monitoring the path state. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxStatePathId 1.3.6.1.4.1.495.2.1.1.2.3.3.1.4
Displays the Path ID or Group ID that the user dials to access the remote telephone or fax machine. Displays the Path ID or Group ID that the user dials to access the remote telephone or fax machine. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathId of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxStateDateAndTime 1.3.6.1.4.1.495.2.1.1.2.3.3.1.5
Displays the date and time the link associated with the Path/Group ID changed state (i.e. the call was initiated). The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week, 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(20..20)  

cxMcVoxStateLnkState 1.3.6.1.4.1.495.2.1.1.2.3.3.1.6
Displays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a remote chassis location that does not exist. remError (2): all voice ports at the specified remote are inactive and therefore cannot accept the call. It is possible that the remote ports are disabled or that the I/O card is not installed. busy (3): all voice ports at the specified remote are busy and therefore unavailable to accept the call. open (4): the call was successfully put through to a voice port at the remote location. errActiveChn (5): the end-user has replaced the receiver (on-hook) at the end of a call and then removed the receiver (off-hook) so quickly that the connection has not had sufficient time to completely disconnect. The end-user should wait a few seconds after replacing the receiver before attempting to place another call. errPath (6): the Path ID (dialing code) the user entered is not listed in the routing table. Check that the Path ID and routing are completely configured. errLnk (7): there is an error condition on the line between the local and remote link stations causing the link to be inactive. fixedLnkDown (8): Memotec use only. Contact Memotec sevice personnel if this value displays. fixedLnkUp (9): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none
OBJECT-TYPE    
  INTEGER remUnavailable(1), remError(2), busy(3), open(4), errActiveChn(5), errPath(6), errLnk(7), fixedLnkDown(8), fixedLnkUp(9)  

cxMcVoxStateRmtExt 1.3.6.1.4.1.495.2.1.1.2.3.3.1.7
Displays the Remote Extension or Group ID that the user dials to access the remote telephone or fax machine. You cannot modify this object. Range of Values: 1 to 5 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxPathAdmTable 1.3.6.1.4.1.495.2.1.1.2.4
Planned pathID table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxPathAdmEntry

cxMcVoxHistoryTrap 1.3.6.1.4.1.495.2.1.1.2.4
Informs the management station of the fact that the history table needs servicing.
TRAP-TYPE    
  cxModuleHwPhysSlot  
  cxMcVoxHistoryIndex  
  cxMcVoxGlobalHistoryMaxNumberOfEntries  

cxMcVoxPathAdmEntry 1.3.6.1.4.1.495.2.1.1.2.4.1
Planned pathID row definition.
OBJECT-TYPE    
  CxMcVoxPathAdmEntry  

cxMcVoxPathAdmIndex 1.3.6.1.4.1.495.2.1.1.2.4.1.1
Displays the index number of the Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
OBJECT-TYPE    
  INTEGER 1..300  

cxMcVoxPathAdmRowStatus 1.3.6.1.4.1.495.2.1.1.2.4.1.2
Determines the status of the objects in a table row. Options: invalid (1): Row is deleted from the table immediately, however values are still in effect until the next reset. valid (2): Use this value to add a new row to the table, or modify an existing row. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxPathAdmPathId 1.3.6.1.4.1.495.2.1.1.2.4.1.3
Determines the administrative numeric dialing code that the user enters to access the remote telephone or fax machine. Note: The length of the ID must match the value you define for the object cxMcVoxPathAdmPathLng (of this table). Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxPathAdmRemStationId 1.3.6.1.4.1.495.2.1.1.2.4.1.4
Determines the administrative ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can be defined. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

cxMcVoxPathAdmHunt 1.3.6.1.4.1.495.2.1.1.2.4.1.5
Determines the port numbers included in the administrative Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with the object cxMcVoxPathAdmRemStationId of this table). The Path ID (defined using the object cxMcVoxPathAdmId of this table) references this Hunt Group during call establishment. Each port in the Hunt Group is polled until one of the ports accepts the call. A maximum of 32 ports can be in a single hunt group. Range of Values: 1 to 4294967295 Default Value: 65535 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxPathAdmLng 1.3.6.1.4.1.495.2.1.1.2.4.1.6
Determines the length (in digits) of the administrative Path ID. Note: If you modify the current operative value to one that is a lower digit, the current operative Path IDs (using the higher value) will be lost once the administrative setting is initialized. Range of Values: 1 to 4 Default Value: 3 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxPathOpeTable 1.3.6.1.4.1.495.2.1.1.2.5
Active pathID table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxPathOpeEntry

cxMcVoxPathOpeEntry 1.3.6.1.4.1.495.2.1.1.2.5.1
Active pathID row definition.
OBJECT-TYPE    
  CxMcVoxPathOpeEntry  

cxMcVoxPathOpeIndex 1.3.6.1.4.1.495.2.1.1.2.5.1.1
Displays the index number of the operational Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
OBJECT-TYPE    
  INTEGER 1..300  

cxMcVoxPathOpePathId 1.3.6.1.4.1.495.2.1.1.2.5.1.2
Displays the operational Path ID. The Path ID is the numeric dialing code the user enters to gain access to the remote telephone or fax machine. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathId of the cxMcVox Administrative Configuration Group. Range of Values: 1 to 4 digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxPathOpeRemStationId 1.3.6.1.4.1.495.2.1.1.2.5.1.3
Displays the operational ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can be defined. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmRemStationId of the cxMcVox Administrative Net group Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

cxMcVoxPathOpeHunt 1.3.6.1.4.1.495.2.1.1.2.5.1.4
Displays the port numbers included in the operational Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with the object cxMcVoxPathAdmRemStationId of this table). The Path ID (defined using the object cxMcVoxPathAdmId of this table) references this hunt group during call establishment. Each port in the Hunt Group is polled until one of the ports accepts the call. A maximum of 8 ports can be in a single hunt group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmHunt of the cxMcVox Administrative Path Group. Range of Values: 1 to 4294967295 Default Value: 65535
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxPathOpeLng 1.3.6.1.4.1.495.2.1.1.2.5.1.5
Displays the length (in digits) of the operative Path ID. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 Default Value: 3
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxNetAdmTable 1.3.6.1.4.1.495.2.1.1.2.6
Planned NET entries.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxNetAdmEntry

cxMcVoxNetAdmEntry 1.3.6.1.4.1.495.2.1.1.2.6.1
Planned NET row.
OBJECT-TYPE    
  CxMcVoxNetAdmEntry  

cxMcVoxNetAdmIndex 1.3.6.1.4.1.495.2.1.1.2.6.1.1
Displays the index number of the administrative network routing entry. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
OBJECT-TYPE    
  INTEGER 1..300  

cxMcVoxNetAdmRowStatus 1.3.6.1.4.1.495.2.1.1.2.6.1.2
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxNetAdmRemStationId 1.3.6.1.4.1.495.2.1.1.2.6.1.3
Determines the administrative ID (name) of the remote voice station. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

cxMcVoxNetAdmLocalLnkStation 1.3.6.1.4.1.495.2.1.1.2.6.1.4
Determines the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..16  

cxMcVoxNetAdmRoute 1.3.6.1.4.1.495.2.1.1.2.6.1.5
Determines the number that identifies the administrative link entry in the GMF (Gateway Mux Frame Relay). The network administrator assigns this number in sequential order starting at 1. You then must establish an internal system route from the GMF route number to a Frame Relay circuit alias using the objects gmfSRLink and gmfSRDestCircuitAlias of the GMF System Routing Definition Group. Range of Values: 1 to 1024 Default Value: 1 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..1024  

cxMcVoxNetAdmRemVoxStation 1.3.6.1.4.1.495.2.1.1.2.6.1.6
Determines the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architecture. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..16  

cxMcVoxNetOpeTable 1.3.6.1.4.1.495.2.1.1.2.7
Active net entries table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxNetOpeEntry

cxMcVoxNetOpeEntry 1.3.6.1.4.1.495.2.1.1.2.7.1
Active net entry row definition.
OBJECT-TYPE    
  CxMcVoxNetOpeEntry  

cxMcVoxNetOpeIndex 1.3.6.1.4.1.495.2.1.1.2.7.1.1
Displays the index number of the operative network routing entry. You cannot modify this object Range of Values: 1 to 300 Default Value: none
OBJECT-TYPE    
  INTEGER 1..300  

cxMcVoxNetOpeRemStationId 1.3.6.1.4.1.495.2.1.1.2.7.1.2
Displays the operative ID (name) of the remote voice station. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeRemStationId of the cxMcVox Administrative Net Group. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

cxMcVoxNetOpeLocalLnkStation 1.3.6.1.4.1.495.2.1.1.2.7.1.3
Displays the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeLocalLnkStation of the cxMcVox Administrative Net Group. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1
OBJECT-TYPE    
  INTEGER 1..16  

cxMcVoxNetOpeRoute 1.3.6.1.4.1.495.2.1.1.2.7.1.4
Displays the number that identifies the operative link entry. The network administrator assigns this number to identify the route in the routing table. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeRoute of the cxMcVox Administrative Net Group. Range of Values: 1 to 1024 Default Value: 1
OBJECT-TYPE    
  INTEGER 1..1024  

cxMcVoxNetOpeRemVoxStation 1.3.6.1.4.1.495.2.1.1.2.7.1.5
Displays the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architecture. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmRemVoxStation of the cxMcVox Administrative Net Group. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1
OBJECT-TYPE    
  INTEGER 1..16  

cxMcVoxDriverAdm 1.3.6.1.4.1.495.2.1.1.2.8
OBJECT IDENTIFIER    

cxMcVoxEmAdmTable 1.3.6.1.4.1.495.2.1.1.2.8.1
Voice station planned E&M Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxEmAdmEntry

cxMcVoxEmAdmEntry 1.3.6.1.4.1.495.2.1.1.2.8.1.1
Voice station planned E&M row definition.
OBJECT-TYPE    
  CxMcVoxEmAdmEntry  

cxMcVoxEmAdmCardUsed 1.3.6.1.4.1.495.2.1.1.2.8.1.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxEmAdmPortUsed 1.3.6.1.4.1.495.2.1.1.2.8.1.1.2
Displays the number of the voice port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxEmAdmPortStatus 1.3.6.1.4.1.495.2.1.1.2.8.1.1.3
Determines the functional status of the administrative E&M port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxEmAdmVocoder 1.3.6.1.4.1.495.2.1.1.2.8.1.1.4
Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative E&M port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxEmAdmFaxBw 1.3.6.1.4.1.495.2.1.1.2.8.1.1.5
Determines the speed (in bits per second) of the FAX channel on the administrative E&M port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxEmAdmAutoCnx 1.3.6.1.4.1.495.2.1.1.2.8.1.1.6
Obsolete.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxEmAdmPathId 1.3.6.1.4.1.495.2.1.1.2.8.1.1.7
Path IDs no longer exist in the new Voice Routing (VR) scheme. Determines the Path ID used for auto-connection on the administrative E&M port. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxEmAdmTxGain 1.3.6.1.4.1.495.2.1.1.2.8.1.1.8
Determines the value defining the sound intensity (loudness) of voice transmissions on the administrative E&M port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxEmAdmRxGain 1.3.6.1.4.1.495.2.1.1.2.8.1.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the administrative E&M port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxEmAdmEchoCancel 1.3.6.1.4.1.495.2.1.1.2.8.1.1.10
Determines the state of echo cancellation on the administrative E&M port. When set to 'enable', at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxEmAdmType 1.3.6.1.4.1.495.2.1.1.2.8.1.1.11
Determines the type of E&M interface on the administrative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Make sure that you select the interface type that matches your PBX. Options: type-1 (1) type-2 (2) type-3 (3) type-4 (4) type-5 (5) Default Value: type-2 (2) Configuration Changed: administrative NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER type-1(1), type-2(2), type-3(3), type-4(4), type-5(5)  

cxMcVoxEmAdmMode 1.3.6.1.4.1.495.2.1.1.2.8.1.1.12
Determines the signalling mode for the administrative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. The mode you select must match the type the PBX punch block uses or the port will not be able to communicate with it. Options: normal (1) reverse (2) Default Value: normal Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER normal(1), reverse(2)  

cxMcVoxEmAdmDialType 1.3.6.1.4.1.495.2.1.1.2.8.1.1.13
Determines the dialing method of the administrative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. mfR1 (3): R1 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 dBm0 +- 1 dB (CCITT Recommendation Q.322). The difference in transmission level between the two frequencies comprises a signal that does not exceed 0.5 dB. mfR2 (4): R2 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -8 dBm0 +- 1 dB (CCITT Recommendation Q.454). The difference in transmission level between the two frequencies comprises a signal that does not exceed 1 dB. Default Value: dtmf (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2), mfR1(3), mfR2(4)  

cxMcVoxEmAdmSignalType 1.3.6.1.4.1.495.2.1.1.2.8.1.1.14
Determines the type of signalling on the administrative E&M port. The signalling type refers to the line seizure technique Options: normal (1) delay (2) wink (3) ac15 (4) openChn (5) R2 (6) MFCR2 (7) isdn (8) Note: If you select 'ac15' you must define the object cxMcVoxEmAdmDialType of this table. Default Value: normal Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3), ac15(4), openchn(5), r2(6), mfcr2(7), isdn(8)  

cxMcVoxEmAdmAc15Type 1.3.6.1.4.1.495.2.1.1.2.8.1.1.15
Determines the type of AC15 signals the administrative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Options: normal (1) delay (2) Default Value: normal Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER normal(1), delay(2)  

cxMcVoxEmAdmAc15TimeOn 1.3.6.1.4.1.495.2.1.1.2.8.1.1.16
Determines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Range of Values: 0 to 60000 Default Value: 60 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxEmAdmAc15TimeOff 1.3.6.1.4.1.495.2.1.1.2.8.1.1.17
Determines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Range of Values: 0 to 60000 Default Value: 40 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxEmAdmCnctType 1.3.6.1.4.1.495.2.1.1.2.8.1.1.18
Determines the method the administrative E&M port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxEmAdmRingType 1.3.6.1.4.1.495.2.1.1.2.8.1.1.19
Determines the ring type of the administrative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxEmAdmRmtExt 1.3.6.1.4.1.495.2.1.1.2.8.1.1.20
Determines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxEmAdmRmtId 1.3.6.1.4.1.495.2.1.1.2.8.1.1.21
Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: A maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxEmAdmTranspMode 1.3.6.1.4.1.495.2.1.1.2.8.1.1.22
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxEmAdmFaxEnable 1.3.6.1.4.1.495.2.1.1.2.8.1.1.23
Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxEmAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxEmAdmBroadcast 1.3.6.1.4.1.495.2.1.1.2.8.1.1.24
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxEmAdmImpedance 1.3.6.1.4.1.495.2.1.1.2.8.1.1.25
Displays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxEmAdmVoiceConnection 1.3.6.1.4.1.495.2.1.1.2.8.1.1.26
Indicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)
OBJECT-TYPE    
  INTEGER two-wires(1), four-wires(2)  

cxMcVoxFxsAdmTable 1.3.6.1.4.1.495.2.1.1.2.8.2
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxFxsAdmEntry

cxMcVoxFxsAdmEntry 1.3.6.1.4.1.495.2.1.1.2.8.2.1
OBJECT-TYPE    
  CxMcVoxFxsAdmEntry  

cxMcVoxFxsAdmCardUsed 1.3.6.1.4.1.495.2.1.1.2.8.2.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxFxsAdmPortUsed 1.3.6.1.4.1.495.2.1.1.2.8.2.1.2
Displays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port CX1000: 1 or 2 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxFxsAdmPortStatus 1.3.6.1.4.1.495.2.1.1.2.8.2.1.3
Determines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxsAdmVocoder 1.3.6.1.4.1.495.2.1.1.2.8.2.1.4
Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXS port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxFxsAdmFaxBw 1.3.6.1.4.1.495.2.1.1.2.8.2.1.5
Determines the speed (in bits per second) of the FAX channel on the administrative FXS port. This value also determines the bandwidth required to pass FAX traffic through the voice software.This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxFxsAdmAutoCnx 1.3.6.1.4.1.495.2.1.1.2.8.2.1.6
obsolete
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxFxsAdmPathId 1.3.6.1.4.1.495.2.1.1.2.8.2.1.7
Path IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group Range of Values: 1 to 4 digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxFxsAdmTxGain 1.3.6.1.4.1.495.2.1.1.2.8.2.1.8
Determines the value defining the sound intensity (loudness) of voice transmissions on the administrative FXS port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxsAdmRxGain 1.3.6.1.4.1.495.2.1.1.2.8.2.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the administrative FXS port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxsAdmEchoCancel 1.3.6.1.4.1.495.2.1.1.2.8.2.1.10
Determines the state of echo cancellation on the administrative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxsAdmSignaling 1.3.6.1.4.1.495.2.1.1.2.8.2.1.11
Determines the type of signalling the administrative FXS port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER ground-start(1), loop-start(2), did(3)  

cxMcVoxFxsAdmTimeOn 1.3.6.1.4.1.495.2.1.1.2.8.2.1.12
obsolete
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxFxsAdmTimeOff 1.3.6.1.4.1.495.2.1.1.2.8.2.1.13
obsolete
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxFxsAdmCnctType 1.3.6.1.4.1.495.2.1.1.2.8.2.1.14
Determines the method the administrative FXS port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxFxsAdmRingType 1.3.6.1.4.1.495.2.1.1.2.8.2.1.15
Determines the ring type of the administrative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxFxsAdmImpedance 1.3.6.1.4.1.495.2.1.1.2.8.2.1.16
Determines the input line impedance of the administrative FXS port. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Configuration Changed: administrative NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxFxsAdmDialType 1.3.6.1.4.1.495.2.1.1.2.8.2.1.17
Determines the dialing method of the administrative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

cxMcVoxFxsAdmDidSignalType 1.3.6.1.4.1.495.2.1.1.2.8.2.1.18
Note: This object only applies to those ports with the object cxMcVoxFxsAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXS port. The signaling type refers to the line seizure technique. Options: normal (1) delay (2) wink (3) Default Value: normal (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3)  

cxMcVoxFxsAdmRmtExt 1.3.6.1.4.1.495.2.1.1.2.8.2.1.19
Determines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to access the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxFxsAdmRmtId 1.3.6.1.4.1.495.2.1.1.2.8.2.1.20
Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type connection. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxFxsAdmTranspMode 1.3.6.1.4.1.495.2.1.1.2.8.2.1.21
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxFxsAdmFaxEnable 1.3.6.1.4.1.495.2.1.1.2.8.2.1.22
Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxFxsAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxsAdmBroadcast 1.3.6.1.4.1.495.2.1.1.2.8.2.1.23
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxFxoAdmTable 1.3.6.1.4.1.495.2.1.1.2.8.3
cx Voice Station Administrative FXO Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxFxoAdmEntry

cxMcVoxFxoAdmEntry 1.3.6.1.4.1.495.2.1.1.2.8.3.1
cx Voice Station Administrative FXO Entry
OBJECT-TYPE    
  CxMcVoxFxoAdmEntry  

cxMcVoxFxoAdmCardUsed 1.3.6.1.4.1.495.2.1.1.2.8.3.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxFxoAdmPortUsed 1.3.6.1.4.1.495.2.1.1.2.8.3.1.2
Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxFxoAdmPortStatus 1.3.6.1.4.1.495.2.1.1.2.8.3.1.3
Determines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxoAdmVocoder 1.3.6.1.4.1.495.2.1.1.2.8.3.1.4
Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXO port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxFxoAdmFaxBw 1.3.6.1.4.1.495.2.1.1.2.8.3.1.5
Determines the speed (in bits per second) of the FAX channel on the administrative FXO port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxFxoAdmAutoCnx 1.3.6.1.4.1.495.2.1.1.2.8.3.1.6
obsolete
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxFxoAdmPathId 1.3.6.1.4.1.495.2.1.1.2.8.3.1.7
Path IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxFxoAdmTxGain 1.3.6.1.4.1.495.2.1.1.2.8.3.1.8
Determines the value defining the sound intensity (loudness) of voice transmission on the administrative FXO port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxoAdmRxGain 1.3.6.1.4.1.495.2.1.1.2.8.3.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the administrative FXO port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxoAdmEchoCancel 1.3.6.1.4.1.495.2.1.1.2.8.3.1.10
Determines the state of echo cancellation on the administrative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxoAdmSignaling 1.3.6.1.4.1.495.2.1.1.2.8.3.1.11
Determines the type of signalling the administrative FXO port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER ground-start(1), loop-start(2), did(3)  

cxMcVoxFxoAdmCnctType 1.3.6.1.4.1.495.2.1.1.2.8.3.1.12
Determines the method the administrative FXO port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxFxoAdmRingType 1.3.6.1.4.1.495.2.1.1.2.8.3.1.13
Determines the ring type of the administrative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxFxoAdmImpedance 1.3.6.1.4.1.495.2.1.1.2.8.3.1.14
Determines the input line impedance of the administrative FXO interface. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Configuration Changed: administrative NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxFxoAdmDialType 1.3.6.1.4.1.495.2.1.1.2.8.3.1.15
Determines the dialing method of the administrative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf 1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

cxMcVoxFxoAdmDidSignalType 1.3.6.1.4.1.495.2.1.1.2.8.3.1.16
Note: This object only applies to those ports with the object cxMcVoxFxoAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXO port. The signaling type refers to the line seizure technique. Options: normal (1) delay (2) wink (3) Default Value: normal (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3)  

cxMcVoxFxoAdmRmtExt 1.3.6.1.4.1.495.2.1.1.2.8.3.1.17
Determines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxFxoAdmRmtId 1.3.6.1.4.1.495.2.1.1.2.8.3.1.18
Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type connection. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxFxoAdmTranspMode 1.3.6.1.4.1.495.2.1.1.2.8.3.1.19
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxFxoAdmFaxEnable 1.3.6.1.4.1.495.2.1.1.2.8.3.1.20
Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxFxoAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxoAdmBroadcast 1.3.6.1.4.1.495.2.1.1.2.8.3.1.21
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxDriverOpe 1.3.6.1.4.1.495.2.1.1.2.9
OBJECT IDENTIFIER    

cxMcVoxEmOpeTable 1.3.6.1.4.1.495.2.1.1.2.9.1
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxEmOpeEntry

cxMcVoxEmOpeEntry 1.3.6.1.4.1.495.2.1.1.2.9.1.1
OBJECT-TYPE    
  CxMcVoxEmOpeEntry  

cxMcVoxEmOpeCardUsed 1.3.6.1.4.1.495.2.1.1.2.9.1.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxEmOpePortUsed 1.3.6.1.4.1.495.2.1.1.2.9.1.1.2
Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxEmOpePortStatus 1.3.6.1.4.1.495.2.1.1.2.9.1.1.3
Displays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmportStatus of the cxMcVox Administrative Driver Group. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)
OBJECT-TYPE    
  INTEGER disable(1), enable(2), no-voice-io(3), boot-err-1(31), boot-err-2(32), boot-err-3(33), boot-err-4(34), appl-err-1(41), appl-err-2(42), appl-err-3(43), appl-err-4(44)  

cxMcVoxEmOpeVocoder 1.3.6.1.4.1.495.2.1.1.2.9.1.1.4
Displays the transmission speed (in bits per second) of the compressed voice stream on the operative E&M port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmVocoder of the cxMcVox Administrative Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxEmOpeFaxBw 1.3.6.1.4.1.495.2.1.1.2.9.1.1.5
Determines the speed (in bits per second) of the FAX channel on the operative E&M port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxEmOpeAutoCnx 1.3.6.1.4.1.495.2.1.1.2.9.1.1.6
obsolete
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxEmOpePathId 1.3.6.1.4.1.495.2.1.1.2.9.1.1.7
Path IDs no longer exist in the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmPathId of the cxMcVox Administrative Driver Group. Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxEmOpeTxGain 1.3.6.1.4.1.495.2.1.1.2.9.1.1.8
Determines the value defining the sound intensity (loudness) of voice transmissions on the operative E&M port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxEmOpeRxGain 1.3.6.1.4.1.495.2.1.1.2.9.1.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the operative E&M port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxEmOpeEchoCancel 1.3.6.1.4.1.495.2.1.1.2.9.1.1.10
Displays the state of echo cancellation on the operative E&M port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmEchoCancel of the cxMcVox Administrative Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxEmOpeType 1.3.6.1.4.1.495.2.1.1.2.9.1.1.11
Displays the type of E&M interface of the operative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Be sure to select the interface type that matches your PBX. You cannot modify this object. If you want to change thevalue you must modify the object cxMcVoxEmAdmType of the cxMcVox Administrative Driver Group. Options: type-1 (1) type-2 (2) type-3 (3) type-4 (4) type-5 (5) Default Value: type-2 (2)
OBJECT-TYPE    
  INTEGER type-1(1), type-2(2), type-3(3), type-4(4), type-5(5)  

cxMcVoxEmOpeMode 1.3.6.1.4.1.495.2.1.1.2.9.1.1.12
Displays the signalling mode for the operative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. The mode you select must match the type the PBX punch block uses or the port will not be able to communicate with it. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmMode of the cxMcVox Administrative Driver Group. Options: normal (1) reverse (2) Default Value: normal (1)
OBJECT-TYPE    
  INTEGER normal(1), reverse(2)  

cxMcVoxEmOpeDialType 1.3.6.1.4.1.495.2.1.1.2.9.1.1.13
Displays the dialing method of the operative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmDialType of the cxMcVox Administrative Driver Group Options: dtmf (1): Dual Tone MultiFrequency uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. mfR1 (3): R1 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 dBm0 +- 1 dB (CCITT Recommendation Q.322). The difference in transmission level between the two frequencies comprises a signal that does not exceed 0.5 dB. mfR2 (4): R2 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -8 dBm0 +- 1 dB (CCITT Recommendation Q.454). The difference in transmission level between the two frequencies comprises a signal that does not exceed 1 dB. Default Value: dtmf (1)
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2), mfR1(3), mfR2(4)  

cxMcVoxEmOpeSignalType 1.3.6.1.4.1.495.2.1.1.2.9.1.1.14
Displays the type of signalling the operative E&M port uses to seize the line. You cannot modify this object. If you want to change the value you must modify thee object cxMcVoxEmAdmSignalType of the cxMcVox Administrative Driver Group. Options: normal (1) delay (2) wink (3) ac15 (4) openChn (5) R2 (6) MFCR2 (7) isdn (8) Default Value: normal (1)
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3), ac15(4), openchn(5), r2(6), mfcr2(7), isdn(8)  

cxMcVoxEmOpeAc15Type 1.3.6.1.4.1.495.2.1.1.2.9.1.1.15
Displays the type of AC15 signals the operative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of the cxMcVox Administrative Driver Group). You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmAcType of the cxMcVox Administrative Driver Group. Options: normal (1) delay (2) Default Value: normal
OBJECT-TYPE    
  INTEGER normal(1), delay(2)  

cxMcVoxEmOpeAc15TimeOn 1.3.6.1.4.1.495.2.1.1.2.9.1.1.16
Determines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). Range of Values: 0 to 60000 Default Value: 60 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxEmOpeAc15TimeOff 1.3.6.1.4.1.495.2.1.1.2.9.1.1.17
Determines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). Range of Values: 0 to 60000 Default Value: 40 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxEmOpeCnctType 1.3.6.1.4.1.495.2.1.1.2.9.1.1.18
Displays the method the operative E&M port uses to make connections. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmCnctType of the cxMcVox Administrative Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxEmOpeRingType 1.3.6.1.4.1.495.2.1.1.2.9.1.1.19
Displays the ring type of the operative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmRingType of the cxMcVox Administrative Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxEmOpeRmtExt 1.3.6.1.4.1.495.2.1.1.2.9.1.1.20
Determines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxEmOpeRmtId 1.3.6.1.4.1.495.2.1.1.2.9.1.1.21
Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxEmAdmRmtId (of this table). With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxEmOpeTranspMode 1.3.6.1.4.1.495.2.1.1.2.9.1.1.22
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxEmOpeFaxEnable 1.3.6.1.4.1.495.2.1.1.2.9.1.1.23
Displays the state of the FAX on the operative E&M port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmFaxEnable of the cxMcVox Administrative Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxEmOpeBroadcast 1.3.6.1.4.1.495.2.1.1.2.9.1.1.24
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxEmOpeImpedance 1.3.6.1.4.1.495.2.1.1.2.9.1.1.25
Displays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxEmOpeVoiceConnection 1.3.6.1.4.1.495.2.1.1.2.9.1.1.26
Indicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)
OBJECT-TYPE    
  INTEGER two-wires(1), four-wires(2)  

cxMcVoxFxsOpeTable 1.3.6.1.4.1.495.2.1.1.2.9.2
cx Voice Station active FXS Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxFxsOpeEntry

cxMcVoxFxsOpeEntry 1.3.6.1.4.1.495.2.1.1.2.9.2.1
cx Voice Station active FXS Entry
OBJECT-TYPE    
  CxMcVoxFxsOpeEntry  

cxMcVoxFxsOpeCardUsed 1.3.6.1.4.1.495.2.1.1.2.9.2.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxFxsOpePortUsed 1.3.6.1.4.1.495.2.1.1.2.9.2.1.2
Displays the number of the voice I/O port. You cannot modify this object Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxFxsOpePortStatus 1.3.6.1.4.1.495.2.1.1.2.9.2.1.3
Displays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmportStatus of the cxMcVox Administrative FXS Driver Group. Options: disable (1): port is not functional enabled (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): = Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)
OBJECT-TYPE    
  INTEGER disable(1), enable(2), no-voice-io(3), boot-err-1(31), boot-err-2(32), boot-err-3(33), boot-err-4(34), appl-err-1(41), appl-err-2(42), appl-err-3(43), appl-err-4(44)  

cxMcVoxFxsOpeVocoder 1.3.6.1.4.1.495.2.1.1.2.9.2.1.4
Displays the transmission speed (in bits per second) of the compressed voice stream on the operative FXS port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmVocoder of the cxMcVox Administrative FXS Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2)
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxFxsOpeFaxBw 1.3.6.1.4.1.495.2.1.1.2.9.2.1.5
Determines the speed (in bits per second) of the FAX channel on the operative FXS port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxFxsOpeAutoCnx 1.3.6.1.4.1.495.2.1.1.2.9.2.1.6
Obsolete
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxFxsOpePathId 1.3.6.1.4.1.495.2.1.1.2.9.2.1.7
Path IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXS port. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmPathId of the cxMcVox Administrative FXS Driver Group. Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxFxsOpeTxGain 1.3.6.1.4.1.495.2.1.1.2.9.2.1.8
Determines the value defining the sound intensity (loudness) of voice transmissions on the operative FXS port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxsOpeRxGain 1.3.6.1.4.1.495.2.1.1.2.9.2.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the operative FXS port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxsOpeEchoCancel 1.3.6.1.4.1.495.2.1.1.2.9.2.1.10
Displays the state of echo cancellation on the operative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmEchoCancel of the cxMcVox Administrative FXS Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxsOpeSignaling 1.3.6.1.4.1.495.2.1.1.2.9.2.1.11
Displays the type of signalling the operative FXS port uses to seize the line. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxfxsAdmSignaling of the cxMcVox Administrative FXS Driver Group. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start
OBJECT-TYPE    
  INTEGER ground-start(1), loop-start(2), did(3)  

cxMcVoxFxsOpeTimeOn 1.3.6.1.4.1.495.2.1.1.2.9.2.1.12
Obsolete
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxFxsOpeTimeOff 1.3.6.1.4.1.495.2.1.1.2.9.2.1.13
Obsoleted
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxFxsOpeCnctType 1.3.6.1.4.1.495.2.1.1.2.9.2.1.14
Displays the method the operative FXS port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmCnctType of the cxMcVox Administrative FXS Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxFxsOpeRingType 1.3.6.1.4.1.495.2.1.1.2.9.2.1.15
Displays the ring type of the operative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmRingType of the cxMcVox Administrative FXS Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxFxsOpeImpedance 1.3.6.1.4.1.495.2.1.1.2.9.2.1.16
Displays the input line impedance of the operative FXS interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxFxsOpeDialType 1.3.6.1.4.1.495.2.1.1.2.9.2.1.17
Displays the dialing method of the operative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmDialType of the cxMcVox Administrative FXS Driver Group table. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1)
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

cxMcVoxFxsOpeDidSignalType 1.3.6.1.4.1.495.2.1.1.2.9.2.1.18
Displays the type of signaling on the operative FXS port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmDidSignalType of the cxMcVox Administrative FXS Driver Group table. Options normal (1) delay (2) wink (3) Default Value: normal (1)
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3)  

cxMcVoxFxsOpeRmtExt 1.3.6.1.4.1.495.2.1.1.2.9.2.1.19
Determines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxFxsOpeRmtId 1.3.6.1.4.1.495.2.1.1.2.9.2.1.20
Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxFxsAdmRmtId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxFxsOpeTranspMode 1.3.6.1.4.1.495.2.1.1.2.9.2.1.21
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxFxsOpeFaxEnable 1.3.6.1.4.1.495.2.1.1.2.9.2.1.22
Displays the state of the FAX on the operative FXS port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmFaxEnable of the cxMcVox Administrative FXS Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxsOpeBroadcast 1.3.6.1.4.1.495.2.1.1.2.9.2.1.23
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxFxoOpeTable 1.3.6.1.4.1.495.2.1.1.2.9.3
cx Voice Station active FXO Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxFxoOpeEntry

cxMcVoxFxoOpeEntry 1.3.6.1.4.1.495.2.1.1.2.9.3.1
cx Voice Station active FXO Entry
OBJECT-TYPE    
  CxMcVoxFxoOpeEntry  

cxMcVoxFxoOpeCardUsed 1.3.6.1.4.1.495.2.1.1.2.9.3.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxFxoOpePortUsed 1.3.6.1.4.1.495.2.1.1.2.9.3.1.2
Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxFxoOpePortStatus 1.3.6.1.4.1.495.2.1.1.2.9.3.1.3
Displays the functional status of the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmportStatus of the cxMcVox Administrative FXO Driver Group. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)
OBJECT-TYPE    
  INTEGER disable(1), enable(2), no-voice-io(3), boot-err-1(31), boot-err-2(32), boot-err-3(33), boot-err-4(34), appl-err-1(41), appl-err-2(42), appl-err-3(43), appl-err-4(44)  

cxMcVoxFxoOpeVocoder 1.3.6.1.4.1.495.2.1.1.2.9.3.1.4
Displays the transmission speed (in bits per second) of the compressed voice stream on the operative FXO port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmVocoder of the cxMcVox Administrative FXO Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2)
OBJECT-TYPE    
  INTEGER bps5800(1), bps8000(2), kbps40(3), kbps32(4), kbps24(5), kbps16(6), opt7(7), opt8(8)  

cxMcVoxFxoOpeFaxBw 1.3.6.1.4.1.495.2.1.1.2.9.3.1.5
Determines the speed (in bits per second) of the FAX channel on the operative FXO port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative
OBJECT-TYPE    
  INTEGER bps2400(1), bps4800(2), bps7200(3), bps9600(4)  

cxMcVoxFxoOpeAutoCnx 1.3.6.1.4.1.495.2.1.1.2.9.3.1.6
Obsolete
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cxMcVoxFxoOpePathId 1.3.6.1.4.1.495.2.1.1.2.9.3.1.7
Path IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXO port. The Path ID is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you modify the object cxMcVoxFxoAdmPathId of the cxMcVox Administrative FXO Driver Group. Range of Values: 1 to 4 digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxFxoOpeTxGain 1.3.6.1.4.1.495.2.1.1.2.9.3.1.8
Determines the value defining the sound intensity (loudness) of voice transmissions on the operative FXO port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxoOpeRxGain 1.3.6.1.4.1.495.2.1.1.2.9.3.1.9
Determines the value defining the sound intensity (loudness) of voice reception on the operative FXO port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxFxoOpeEchoCancel 1.3.6.1.4.1.495.2.1.1.2.9.3.1.10
Displays the state of echo cancellation on the operative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmEchoCancel of the cxMcVox Administrative FXO Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxoOpeSignaling 1.3.6.1.4.1.495.2.1.1.2.9.3.1.11
Displays the type of signalling the operative FXO port uses to seize the line. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmSignaling of the cxMcVox Administrative FXO Driver Group. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start
OBJECT-TYPE    
  INTEGER ground-start(1), loop-start(2), did(3)  

cxMcVoxFxoOpeCnctType 1.3.6.1.4.1.495.2.1.1.2.9.3.1.12
Displays the method the operative FXO port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmCnctType of the cxMcVox Administrative FXO Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)
OBJECT-TYPE    
  INTEGER switched(1), auto-connect(2), fixed(3)  

cxMcVoxFxoOpeRingType 1.3.6.1.4.1.495.2.1.1.2.9.3.1.13
Displays the ring type of the operative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmRingType of the cxMcVox Administrative FXO Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)
OBJECT-TYPE    
  INTEGER north-american(1), international(2)  

cxMcVoxFxoOpeImpedance 1.3.6.1.4.1.495.2.1.1.2.9.3.1.14
Displays the input line impedance of the operative FXO interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800.
OBJECT-TYPE    
  INTEGER i600-ohms(1), i900-ohms(2), att(3), aus(4)  

cxMcVoxFxoOpeDialType 1.3.6.1.4.1.495.2.1.1.2.9.3.1.15
Displays the dialing method of the operative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmDialType of the cxMcVox Administrative FXO Driver Group table. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1)
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

cxMcVoxFxoOpeDidSignalType 1.3.6.1.4.1.495.2.1.1.2.9.3.1.16
Displays the type of signaling on the operative FXO port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmDidSignalType of the cxMcVox Administrative FXO Driver Group table. Options normal (1) delay (2) wink (3) Default Value: normal (1)
OBJECT-TYPE    
  INTEGER normal(1), delay(2), wink(3)  

cxMcVoxFxoOpeRmtExt 1.3.6.1.4.1.495.2.1.1.2.9.3.1.17
Determines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxFxoOpeRmtId 1.3.6.1.4.1.495.2.1.1.2.9.3.1.18
Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxFxoAdmRmtId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cxMcVoxFxoOpeTranspMode 1.3.6.1.4.1.495.2.1.1.2.9.3.1.19
Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational
OBJECT-TYPE    
  INTEGER emulate(1), transparent(2), local(3)  

cxMcVoxFxoOpeFaxEnable 1.3.6.1.4.1.495.2.1.1.2.9.3.1.20
Displays the state of the FAX on the operative FXO port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmFaxEnable of the cxMcVox Administrative FXO Driver Group. Options: disable (1) enable (2) Default Value: enable (2)
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cxMcVoxFxoOpeBroadcast 1.3.6.1.4.1.495.2.1.1.2.9.3.1.21
Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)
OBJECT-TYPE    
  INTEGER none(1), master(2), slave(3)  

cxMcVoxGrpIdAdmTable 1.3.6.1.4.1.495.2.1.1.2.10
Voice Station Group Id identification Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxGrpIdAdmEntry

cxMcVoxGrpIdAdmEntry 1.3.6.1.4.1.495.2.1.1.2.10.1
Associates an entry in the GroupId table with a pathId-like identifier for that groupId.
OBJECT-TYPE    
  CxMcVoxGrpIdAdmEntry  

cxMcVoxGrpIdAdmIndex 1.3.6.1.4.1.495.2.1.1.2.10.1.1
Displays the index number of the administrative Group ID. You cannot modify this object. It is a display that the software provides. Range of Values: 1 to 32 Default Value: none
OBJECT-TYPE    
  INTEGER 1..32  

cxMcVoxGrpIdAdm 1.3.6.1.4.1.495.2.1.1.2.10.1.2
Determines the administrative Group ID. The Group ID is a dialing code that the user enters to gain access to a remote telephone or FAX machine. The group contains up to 48 different Path IDs. Each of these Path IDs (i.e. specific routes to a destination) are polled until one of them is available to handle the call. Each of the Path IDs in the group must be on a separate CPU at the destination. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxGrpIdLenAdm 1.3.6.1.4.1.495.2.1.1.2.10.1.3
Determines the length (in digits) of the administrative Group ID. Range of Values: 1 to 4 Default Value: 3 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxGrpIdAdmRowStatus 1.3.6.1.4.1.495.2.1.1.2.10.1.4
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled. Default Value: valid (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxGrpIdAdmNbPoll 1.3.6.1.4.1.495.2.1.1.2.10.1.5
Determines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object is only relevant if at least one Remote Extension Group ID has been defined using the objects in the cxMcVox Administrative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..20  

cxMcVoxGrpIdOpeTable 1.3.6.1.4.1.495.2.1.1.2.11
cx Voice Station Group Id identification Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxGrpIdOpeEntry

cxMcVoxGrpIdOpeEntry 1.3.6.1.4.1.495.2.1.1.2.11.1
Associates an entry in the GroupId table with a pathId-like identifier for that groupId.
OBJECT-TYPE    
  CxMcVoxGrpIdOpeEntry  

cxMcVoxGrpIdOpeIndex 1.3.6.1.4.1.495.2.1.1.2.11.1.1
Displays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
OBJECT-TYPE    
  INTEGER 1..32  

cxMcVoxGrpIdOpe 1.3.6.1.4.1.495.2.1.1.2.11.1.2
Displays the operative Group ID. The Group ID is a dialing code the user enters to gain access to the remote telephone or FAX machine. The Group ID contains up to 48 different Path IDs. Each of these Path IDs (i.e. specific routes to a destination) are polled until one of them is available to handle the call. Each of the Path IDs in the group must be on a separate CPU at the destination. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxGrpIdAdm of the cxMcVox Administrative Group ID Identificastion Group. Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxGrpIdLenOpe 1.3.6.1.4.1.495.2.1.1.2.11.1.3
Determines the length (in digits) of the operative Group ID. You cannot moify this object. If you want to change the value you must modify the object cxMcVoxGrpIdLenAdm of the cxMcVox Administrative GROUPID identification group Range of Values: 1 to 4 Default Value: 3
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxGrpIdOpeNbPoll 1.3.6.1.4.1.495.2.1.1.2.11.1.4
Determines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object is only relevant if at least one Remote Extension Group ID has been defined using the objects in the cxMcVox Operative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: operative
OBJECT-TYPE    
  INTEGER 1..20  

cxMcVoxGrpDefAdmTable 1.3.6.1.4.1.495.2.1.1.2.12
Planned GroupID definition table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxGrpDefAdmEntry

cxMcVoxGrpDefAdmEntry 1.3.6.1.4.1.495.2.1.1.2.12.1
Planned GroupID row definition.
OBJECT-TYPE    
  CxMcVoxGrpDefAdmEntry  

cxMcVoxGrpDefAdmIndex 1.3.6.1.4.1.495.2.1.1.2.12.1.1
Displays the index number of the administrative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
OBJECT-TYPE    
  INTEGER 1..32  

cxMcVoxGrpDefAdmPriority 1.3.6.1.4.1.495.2.1.1.2.12.1.2
Displays the polling priority level of the administrative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You add a Path ID to a Group ID using the object cxMcVoxGrpDefAdmPathId of this table. You cannot modify this object. Range of Values: 1 to 48. A value of 1 assigns the highest priority to the Path ID. Default Value: none
OBJECT-TYPE    
  INTEGER 1..48  

cxMcVoxGrpDefAdmRowStatus 1.3.6.1.4.1.495.2.1.1.2.12.1.3
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled. Default: valid (2) Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxGrpDefAdmPathId 1.3.6.1.4.1.495.2.1.1.2.12.1.4
Determines the Path ID you want to include in the administrative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxGrpDefAdmRmtExt 1.3.6.1.4.1.495.2.1.1.2.12.1.5
Determines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Remote Extensions that you include in the group will be polled according to their priority until one is available to handle the call. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxGrpDefOpeTable 1.3.6.1.4.1.495.2.1.1.2.13
Active GroupID definition table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxGrpDefOpeEntry

cxMcVoxGrpDefOpeEntry 1.3.6.1.4.1.495.2.1.1.2.13.1
Active GroupID row definition.
OBJECT-TYPE    
  CxMcVoxGrpDefOpeEntry  

cxMcVoxGrpDefOpeIndex 1.3.6.1.4.1.495.2.1.1.2.13.1.1
Displays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
OBJECT-TYPE    
  INTEGER 1..32  

cxMcVoxGrpDefOpePriority 1.3.6.1.4.1.495.2.1.1.2.13.1.2
Displays the polling priority level of the operative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You add a Path ID to a Group ID using the object cxMcVoxGrpDefAdmPathId of the cxMcVox Administrative Grp Group. You cannot modify this object Range of Values: 1 to 48. A value of 1 assigns the highest priority to the Path ID. Default Value: none
OBJECT-TYPE    
  INTEGER 1..48  

cxMcVoxGrpDefOpePathId 1.3.6.1.4.1.495.2.1.1.2.13.1.3
Displays the Path ID included in the operative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxGrpDefAdmPathId of the cxMcVox Administrative GRP Group Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxGrpDefOpeRmtExt 1.3.6.1.4.1.495.2.1.1.2.13.1.4
Determines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefOpePriority of this table). When the user places a call by entering the Group ID, all Remote Extensions that you include in the group will be polled according to their priority, until one is available to handle the call. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxAdmPinTable 1.3.6.1.4.1.495.2.1.1.2.14
Personal identification number Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxAdmPinEntry

cxMcVoxAdmPinEntry 1.3.6.1.4.1.495.2.1.1.2.14.1
Personal identification number row definition.
OBJECT-TYPE    
  CxMcVoxAdmPinEntry  

cxMcVoxAdmPinIndex 1.3.6.1.4.1.495.2.1.1.2.14.1.1
Displays the index number of the Personal Identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256 Default Value: none
OBJECT-TYPE    
  INTEGER 1..256  

cxMcVoxAdmPinCode 1.3.6.1.4.1.495.2.1.1.2.14.1.2
Determines the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station verifies that the PIN included in the call request packet is listed in its PIN table. If it is not,the call will not be established and the user will hear a fast busy signal. Range of Values: 2 to 8 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(2..8)  

cxMcVoxAdmPinRowStatus 1.3.6.1.4.1.495.2.1.1.2.14.1.3
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxOpePinTable 1.3.6.1.4.1.495.2.1.1.2.15
Personal identification number Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxOpePinEntry

cxMcVoxOpePinEntry 1.3.6.1.4.1.495.2.1.1.2.15.1
Personal identification number row definition.
OBJECT-TYPE    
  CxMcVoxOpePinEntry  

cxMcVoxOpePinIndex 1.3.6.1.4.1.495.2.1.1.2.15.1.1
Displays the index number of the Personal identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256. Default Value: none
OBJECT-TYPE    
  INTEGER 1..256  

cxMcVoxOpePinCode 1.3.6.1.4.1.495.2.1.1.2.15.1.2
Displays the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station verifies that the PIN included in the call request packet is listed in its PIN table. If it is not,the call will not be established and the user will hear a fast busy signal. Range of Values: 2 to 8 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(2..8)  

cxMcVoxAdmLclZoneTable 1.3.6.1.4.1.495.2.1.1.2.16
Local Zone Codes Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxAdmLclZoneEntry

cxMcVoxAdmLclZoneEntry 1.3.6.1.4.1.495.2.1.1.2.16.1
Local Zones codes row definition.
OBJECT-TYPE    
  CxMcVoxAdmLclZoneEntry  

cxMcVoxAdmLclZoneIndex 1.3.6.1.4.1.495.2.1.1.2.16.1.1
Displays the index number of the administrative local zone code. Range of Values: 1 to 128. Default Value: none
OBJECT-TYPE    
  INTEGER 1..128  

cxMcVoxAdmLclZoneCode 1.3.6.1.4.1.495.2.1.1.2.16.1.2
Determines the number of the administrative local zone code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Note: The * character is used as a wildcard character. Only one wildcard character can be used per zone code. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmLclZoneLng 1.3.6.1.4.1.495.2.1.1.2.16.1.3
Determines the length (in digits) of the administrative local zone code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmLclZoneRowStatus 1.3.6.1.4.1.495.2.1.1.2.16.1.4
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxOpeLclZoneTable 1.3.6.1.4.1.495.2.1.1.2.17
Local Zones Codes Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxOpeLclZoneEntry

cxMcVoxOpeLclZoneEntry 1.3.6.1.4.1.495.2.1.1.2.17.1
Local Zones codes row definition.
OBJECT-TYPE    
  CxMcVoxOpeLclZoneEntry  

cxMcVoxOpeLclZoneIndex 1.3.6.1.4.1.495.2.1.1.2.17.1.1
Displays the index number of the operational local zone code. Range of Values: 1 to 128. Default Value: none
OBJECT-TYPE    
  INTEGER 1..128  

cxMcVoxOpeLclZoneCode 1.3.6.1.4.1.495.2.1.1.2.17.1.2
Displays the number of the operational local zone code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. You cannot modify this object. If you want to change the code you must change the setting of the cxMcVoxAdmLclZoneCode object in the cxMcVox Administrative Zone Codes Group. Range of Values: 1 to 4 digits from 0 to 9 Note: The * character is used as a wildcard character. Only one wildcard character can be used per zone code. Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeLclZoneLng 1.3.6.1.4.1.495.2.1.1.2.17.1.3
Displays the length (in digits) of the operational local zone code. You cannot modify this object. If you want to change the length you must change the setting of the object cxMcVoxAdmLclZoneLng of the cxMccVox Administrative Local Zone Codes Group. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmRTC 1.3.6.1.4.1.495.2.1.1.2.18
OBJECT IDENTIFIER    

cxMcVoxAdmRTCCountry 1.3.6.1.4.1.495.2.1.1.2.18.1
The CX900 does not currently support this object. Determines the number of the administrative local country code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmRTCCountryLng 1.3.6.1.4.1.495.2.1.1.2.18.2
The CX900 does not currently support this object. Determines the length (in digits) of the administrative local country code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmRTCNonLclCountry 1.3.6.1.4.1.495.2.1.1.2.18.3
The CX900 does not currently support this object. Determines the number of the administrative local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmRTCNonLclCountryLng 1.3.6.1.4.1.495.2.1.1.2.18.4
The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local country code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmRTCArea 1.3.6.1.4.1.495.2.1.1.2.18.5
The CX900 does not currently support this object. Determines the number of the administrative local area code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmRTCAreaLng 1.3.6.1.4.1.495.2.1.1.2.18.6
The CX900 does not currently support this object. Determines the length (in digits) of the administrative local area code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmRTCNonLclArea 1.3.6.1.4.1.495.2.1.1.2.18.7
The CX900 does not currently support this object. Determines the number of the administrative local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmRTCNonLclAreaLng 1.3.6.1.4.1.495.2.1.1.2.18.8
The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local area code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxAdmRTCNonLclZone 1.3.6.1.4.1.495.2.1.1.2.18.9
The CX900 does not currently support this object. Determines the number of the administrative local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxAdmRTCNonLclZoneLng 1.3.6.1.4.1.495.2.1.1.2.18.10
The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local zone code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxOpeRTC 1.3.6.1.4.1.495.2.1.1.2.19
OBJECT IDENTIFIER    

cxMcVoxOpeRTCCountry 1.3.6.1.4.1.495.2.1.1.2.19.1
The CX900 does not currently support this object. Displays the number of the operative local country code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none.
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeRTCCountryLng 1.3.6.1.4.1.495.2.1.1.2.19.2
The CX900 does not currently support this object. Displays the length (in digits) of the operative local country code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxOpeRTCNonLclCountry 1.3.6.1.4.1.495.2.1.1.2.19.3
The CX900 does not currently support this object. Displays the number of the operative local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeRTCNonLclCountryLng 1.3.6.1.4.1.495.2.1.1.2.19.4
The CX900 does not currently support this object. Displays the length (in digits) of the operative non local country code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxOpeRTCArea 1.3.6.1.4.1.495.2.1.1.2.19.5
The CX900 does not currently support this object. Displays the number of the operative local area code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeRTCAreaLng 1.3.6.1.4.1.495.2.1.1.2.19.6
The CX900 does not currently support this object. Displays the length (in digits) of the operative local area code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxOpeRTCNonLclArea 1.3.6.1.4.1.495.2.1.1.2.19.7
The CX900 does not currently support this object. Displays the number of the operative local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeRTCNonLclAreaLng 1.3.6.1.4.1.495.2.1.1.2.19.8
The CX900 does not currently support this object. Displays the length (in digits) of the operative non local area code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxOpeRTCNonLclZone 1.3.6.1.4.1.495.2.1.1.2.19.9
The CX900 does not currently support this object. Displays the number of the operative local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxOpeRTCNonLclZoneLng 1.3.6.1.4.1.495.2.1.1.2.19.10
The CX900 does not currently support this object. Displays the length (in digits) of the operative non local zone code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxDriverAdmPriv 1.3.6.1.4.1.495.2.1.1.2.20
OBJECT IDENTIFIER    

cxMcVoxAdmPortPrivTable 1.3.6.1.4.1.495.2.1.1.2.20.1
Voice station planned Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxAdmPortPrivEntry

cxMcVoxAdmPortPrivEntry 1.3.6.1.4.1.495.2.1.1.2.20.1.1
Voice station planned row definition.
OBJECT-TYPE    
  CxMcVoxAdmPortPrivEntry  

cxMcVoxAdmCardUsed 1.3.6.1.4.1.495.2.1.1.2.20.1.1.1
Displays the slot number of the voice I/O card. You cannot modify this object Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxAdmPortUsed 1.3.6.1.4.1.495.2.1.1.2.20.1.1.2
Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxAdmRingTimeOn 1.3.6.1.4.1.495.2.1.1.2.20.1.1.3
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxAdmRingTimeOff1 1.3.6.1.4.1.495.2.1.1.2.20.1.1.4
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxAdmRingTimeOff2 1.3.6.1.4.1.495.2.1.1.2.20.1.1.5
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxAdmEchoCancelLevel 1.3.6.1.4.1.495.2.1.1.2.20.1.1.6
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100
OBJECT-TYPE    
  INTEGER 0..65535  

cxMcVoxAdmToneDelayAfterCnct 1.3.6.1.4.1.495.2.1.1.2.20.1.1.7
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..6000  

cxMcVoxAdmToneDelayAfterFlash 1.3.6.1.4.1.495.2.1.1.2.20.1.1.8
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400
OBJECT-TYPE    
  INTEGER 0..6000  

cxMcVoxAdmToneOffsetTxGain 1.3.6.1.4.1.495.2.1.1.2.20.1.1.9
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxAdmVoiceOffsetTxGain 1.3.6.1.4.1.495.2.1.1.2.20.1.1.10
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxAdmAc15InterDigit 1.3.6.1.4.1.495.2.1.1.2.20.1.1.11
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmMfToneThold 1.3.6.1.4.1.495.2.1.1.2.20.1.1.12
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxAdmPulseTmin 1.3.6.1.4.1.495.2.1.1.2.20.1.1.13
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxAdmPulseTmax 1.3.6.1.4.1.495.2.1.1.2.20.1.1.14
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxAdmPulseInterDigit 1.3.6.1.4.1.495.2.1.1.2.20.1.1.15
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxAdmDtmfGuard 1.3.6.1.4.1.495.2.1.1.2.20.1.1.16
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxAdmDtmfOpeLevel 1.3.6.1.4.1.495.2.1.1.2.20.1.1.17
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default Value: minus-25 (1)
OBJECT-TYPE    
  INTEGER minus-25(1), minus-28(2), minus-31(3), minus-34(4)  

cxMcVoxAdmDtmfTxTimeOn 1.3.6.1.4.1.495.2.1.1.2.20.1.1.18
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75
OBJECT-TYPE    
  INTEGER 0..500  

cxMcVoxAdmDtmfTxTimeOff 1.3.6.1.4.1.495.2.1.1.2.20.1.1.19
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75
OBJECT-TYPE    
  INTEGER 0..500  

cxMcVoxAdmFlashTmin 1.3.6.1.4.1.495.2.1.1.2.20.1.1.20
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxAdmFlashTmax 1.3.6.1.4.1.495.2.1.1.2.20.1.1.21
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxAdmFlashTgen 1.3.6.1.4.1.495.2.1.1.2.20.1.1.22
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxAdmAfterToneSilences 1.3.6.1.4.1.495.2.1.1.2.20.1.1.23
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 64
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxAdmFaxTxGain 1.3.6.1.4.1.495.2.1.1.2.20.1.1.24
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxAdmFaxRxGain 1.3.6.1.4.1.495.2.1.1.2.20.1.1.25
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxAdmFaxHdlcFlags 1.3.6.1.4.1.495.2.1.1.2.20.1.1.26
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxAdmFaxPreambleDuration 1.3.6.1.4.1.495.2.1.1.2.20.1.1.27
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxPreambleDelay 1.3.6.1.4.1.495.2.1.1.2.20.1.1.28
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxCedToneDuration 1.3.6.1.4.1.495.2.1.1.2.20.1.1.29
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxInterProtoGap 1.3.6.1.4.1.495.2.1.1.2.20.1.1.30
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxTimerDetectSync 1.3.6.1.4.1.495.2.1.1.2.20.1.1.31
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500
OBJECT-TYPE    
  INTEGER 0..65000  

cxMcVoxAdmFaxTimerWaitId 1.3.6.1.4.1.495.2.1.1.2.20.1.1.32
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000
OBJECT-TYPE    
  INTEGER 0..65000  

cxMcVoxAdmFaxMinPreambleDur 1.3.6.1.4.1.495.2.1.1.2.20.1.1.33
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxMaxPreambleDur 1.3.6.1.4.1.495.2.1.1.2.20.1.1.34
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxMinPreambleDly 1.3.6.1.4.1.495.2.1.1.2.20.1.1.35
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxMaxPreambleDly 1.3.6.1.4.1.495.2.1.1.2.20.1.1.36
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxCedToneDetection 1.3.6.1.4.1.495.2.1.1.2.20.1.1.37
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxCedMinToneDur 1.3.6.1.4.1.495.2.1.1.2.20.1.1.38
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxCedMaxToneDur 1.3.6.1.4.1.495.2.1.1.2.20.1.1.39
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxAdmFaxMaxHdlcFlags 1.3.6.1.4.1.495.2.1.1.2.20.1.1.40
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxDriverOpePriv 1.3.6.1.4.1.495.2.1.1.2.21
OBJECT IDENTIFIER    

cxMcVoxOpePortPrivTable 1.3.6.1.4.1.495.2.1.1.2.21.1
Voice station planned Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxOpePortPrivEntry

cxMcVoxOpePortPrivEntry 1.3.6.1.4.1.495.2.1.1.2.21.1.1
Voice station planned row definition.
OBJECT-TYPE    
  CxMcVoxOpePortPrivEntry  

cxMcVoxOpeCardUsed 1.3.6.1.4.1.495.2.1.1.2.21.1.1.1
Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxOpePortUsed 1.3.6.1.4.1.495.2.1.1.2.21.1.1.2
Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxOpeRingTimeOn 1.3.6.1.4.1.495.2.1.1.2.21.1.1.3
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxOpeRingTimeOff1 1.3.6.1.4.1.495.2.1.1.2.21.1.1.4
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxOpeRingTimeOff2 1.3.6.1.4.1.495.2.1.1.2.21.1.1.5
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
OBJECT-TYPE    
  INTEGER 10..10000  

cxMcVoxOpeEchoCancelLevel 1.3.6.1.4.1.495.2.1.1.2.21.1.1.6
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100
OBJECT-TYPE    
  INTEGER 0..65535  

cxMcVoxOpeToneDelayAfterCnct 1.3.6.1.4.1.495.2.1.1.2.21.1.1.7
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..6000  

cxMcVoxOpeToneDelayAfterFlash 1.3.6.1.4.1.495.2.1.1.2.21.1.1.8
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400
OBJECT-TYPE    
  INTEGER 0..6000  

cxMcVoxOpeToneOffsetTxGain 1.3.6.1.4.1.495.2.1.1.2.21.1.1.9
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxOpeVoiceOffsetTxGain 1.3.6.1.4.1.495.2.1.1.2.21.1.1.10
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxOpeAc15InterDigit 1.3.6.1.4.1.495.2.1.1.2.21.1.1.11
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeMfToneThold 1.3.6.1.4.1.495.2.1.1.2.21.1.1.12
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxOpePulseTmin 1.3.6.1.4.1.495.2.1.1.2.21.1.1.13
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxOpePulseTmax 1.3.6.1.4.1.495.2.1.1.2.21.1.1.14
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxOpePulseInterDigit 1.3.6.1.4.1.495.2.1.1.2.21.1.1.15
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275
OBJECT-TYPE    
  INTEGER 0..3000  

cxMcVoxOpeDtmfGuard 1.3.6.1.4.1.495.2.1.1.2.21.1.1.16
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxOpeDtmfOpeLevel 1.3.6.1.4.1.495.2.1.1.2.21.1.1.17
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default Value: minus-25 (1)
OBJECT-TYPE    
  INTEGER minus-25(1), minus-28(2), minus-31(3), minus-34(4)  

cxMcVoxOpeDtmfTxTimeOn 1.3.6.1.4.1.495.2.1.1.2.21.1.1.18
This object is read-only. Range of Values: 0 to 500
OBJECT-TYPE    
  INTEGER 0..500  

cxMcVoxOpeDtmfTxTimeOff 1.3.6.1.4.1.495.2.1.1.2.21.1.1.19
This object is read-only. Range of Values: 0 to 500
OBJECT-TYPE    
  INTEGER 0..500  

cxMcVoxOpeFlashTmin 1.3.6.1.4.1.495.2.1.1.2.21.1.1.20
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxOpeFlashTmax 1.3.6.1.4.1.495.2.1.1.2.21.1.1.21
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxOpeFlashTgen 1.3.6.1.4.1.495.2.1.1.2.21.1.1.22
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500
OBJECT-TYPE    
  INTEGER 50..10000  

cxMcVoxOpeAfterToneSilences 1.3.6.1.4.1.495.2.1.1.2.21.1.1.23
This object is read-only. Range of Values: 0 to 127
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxOpeFaxTxGain 1.3.6.1.4.1.495.2.1.1.2.21.1.1.24
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxOpeFaxRxGain 1.3.6.1.4.1.495.2.1.1.2.21.1.1.25
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
OBJECT-TYPE    
  INTEGER 820..1180  

cxMcVoxOpeFaxHdlcFlags 1.3.6.1.4.1.495.2.1.1.2.21.1.1.26
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxOpeFaxPreambleDuration 1.3.6.1.4.1.495.2.1.1.2.21.1.1.27
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxPreambleDelay 1.3.6.1.4.1.495.2.1.1.2.21.1.1.28
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxCedToneDuration 1.3.6.1.4.1.495.2.1.1.2.21.1.1.29
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxInterProtoGap 1.3.6.1.4.1.495.2.1.1.2.21.1.1.30
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxTimerDetectSync 1.3.6.1.4.1.495.2.1.1.2.21.1.1.31
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500
OBJECT-TYPE    
  INTEGER 0..65000  

cxMcVoxOpeFaxTimerWaitId 1.3.6.1.4.1.495.2.1.1.2.21.1.1.32
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000
OBJECT-TYPE    
  INTEGER 0..65000  

cxMcVoxOpeFaxMinPreambleDur 1.3.6.1.4.1.495.2.1.1.2.21.1.1.33
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxMaxPreambleDur 1.3.6.1.4.1.495.2.1.1.2.21.1.1.34
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxMinPreambleDly 1.3.6.1.4.1.495.2.1.1.2.21.1.1.35
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxMaxPreambleDly 1.3.6.1.4.1.495.2.1.1.2.21.1.1.36
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxCedToneDetection 1.3.6.1.4.1.495.2.1.1.2.21.1.1.37
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxCedMinToneDur 1.3.6.1.4.1.495.2.1.1.2.21.1.1.38
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxCedMaxToneDur 1.3.6.1.4.1.495.2.1.1.2.21.1.1.39
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeFaxMaxHdlcFlags 1.3.6.1.4.1.495.2.1.1.2.21.1.1.40
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32
OBJECT-TYPE    
  INTEGER 0..127  

cxMcVoxTimerOpePriv 1.3.6.1.4.1.495.2.1.1.2.23
OBJECT IDENTIFIER    

cxMcVoxOpeTimerPrivTable 1.3.6.1.4.1.495.2.1.1.2.23.1
Voice station planned Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxOpeTimerPrivEntry

cxMcVoxOpeTimerPrivEntry 1.3.6.1.4.1.495.2.1.1.2.23.1.1
Voice station planned row definition.
OBJECT-TYPE    
  CxMcVoxOpeTimerPrivEntry  

cxMcVoxOpeInterfaceType 1.3.6.1.4.1.495.2.1.1.2.23.1.1.1
Displays the interface type of the voice I/O port. You cannot modify this object Options: em (1) fxs (2) fxo (3) Default: none
OBJECT-TYPE    
  INTEGER em(1), fxs(2), fxo(3)  

cxMcVoxOpeTimeSeizeIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.2
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWaitDialOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.3
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWaitDialIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.4
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 200
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeDialOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.5
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeDialIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.6
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeSiOff 1.3.6.1.4.1.495.2.1.1.2.23.1.1.7
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 300
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeProceed 1.3.6.1.4.1.495.2.1.1.2.23.1.1.8
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeAnswer 1.3.6.1.4.1.495.2.1.1.2.23.1.1.9
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 60000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeBeforeToneOff 1.3.6.1.4.1.495.2.1.1.2.23.1.1.10
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWinkStartIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.11
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 220
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWinkStartOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.12
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 125
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWinkMin 1.3.6.1.4.1.495.2.1.1.2.23.1.1.13
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 140
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeWinkMax 1.3.6.1.4.1.495.2.1.1.2.23.1.1.14
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 290
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeSeize 1.3.6.1.4.1.495.2.1.1.2.23.1.1.15
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeDial 1.3.6.1.4.1.495.2.1.1.2.23.1.1.16
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 210
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeOffIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.17
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeSiOn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.18
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeOffOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.19
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 150
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeDiscIn 1.3.6.1.4.1.495.2.1.1.2.23.1.1.20
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeDiscOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.21
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 650
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxOpeTimeToneOut 1.3.6.1.4.1.495.2.1.1.2.23.1.1.22
WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 15000
OBJECT-TYPE    
  INTEGER 0..60000  

cxMcVoxDiagTable 1.3.6.1.4.1.495.2.1.1.2.24
Voice station diagnostics and events Table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxDiagEntry

cxMcVoxDiagEntry 1.3.6.1.4.1.495.2.1.1.2.24.1
OBJECT-TYPE    
  CxMcVoxDiagEntry  

cxMcVoxDiagCardIndex 1.3.6.1.4.1.495.2.1.1.2.24.1.1
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxDiagPortIndex 1.3.6.1.4.1.495.2.1.1.2.24.1.2
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxDiagScvEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.3
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagGsdEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.4
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagToneInEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.5
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagToneOutEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.6
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagFaxInEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.7
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagFaxOutEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.8
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagGlmEvents 1.3.6.1.4.1.495.2.1.1.2.24.1.9
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagIbvDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.10
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagPcvDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.11
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagGcvDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.12
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagFaxDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.13
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagLseDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.14
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagScvDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.15
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDiagGlmDiags 1.3.6.1.4.1.495.2.1.1.2.24.1.16
OBJECT-TYPE    
  INTEGER no-action(1), trigger(2), reset(3)  

cxMcVoxDownload 1.3.6.1.4.1.495.2.1.1.2.25
OBJECT IDENTIFIER    

cxMcVoxLclExtAdmTable 1.3.6.1.4.1.495.2.1.1.2.26
Planned Local Extensions table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxLclExtAdmEntry

cxMcVoxLclExtAdmEntry 1.3.6.1.4.1.495.2.1.1.2.26.1
Planned Local Extensions row definition.
OBJECT-TYPE    
  CxMcVoxLclExtAdmEntry  

cxMcVoxLclExtAdmIndex 1.3.6.1.4.1.495.2.1.1.2.26.1.1
Displays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none
OBJECT-TYPE    
  INTEGER 1..64  

cxMcVoxLclExtAdmRowStatus 1.3.6.1.4.1.495.2.1.1.2.26.1.2
Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values are disabled and the row is deleted from the table. valid (2): values are enabled. Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

cxMcVoxLclExtAdmExt 1.3.6.1.4.1.495.2.1.1.2.26.1.3
Determines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxLclExtAdmHuntChnl 1.3.6.1.4.1.495.2.1.1.2.26.1.4
Defines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value acts as a mask so that all specified channels are polled until the call is accepted. This hunt channel mask includes a maximum of 30 voice channels. The default value includes all local voice channels. If you want to exclude specific channels, calculate the value by following these steps: 1. Decide which ports to include, for example, 1,5,8,29. 2. Convert the list of ports to a series of bits. Start with a list of 30 zeros. 00 0000 0000 0000 0000 0000 0000 0000 To include ports 1, 5, 8, and 29, place 1s in these positions. Numbering starts at 1 at the extreme right. 01 0000 0000 0000 0000 0000 1001 0001 3. Convert this number to hexadecimal. 10000091 4. Convert this number to decimal. 268 435 601 Range of Values: 1 to 1073741823 Default Value: 1073741823 Configuration Changed: administrative
OBJECT-TYPE    
  INTEGER 1..1073741823  

cxMcVoxLclExtOpeTable 1.3.6.1.4.1.495.2.1.1.2.27
Active Local Extensions table.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxLclExtOpeEntry

cxMcVoxLclExtOpeEntry 1.3.6.1.4.1.495.2.1.1.2.27.1
Active Local Extensions row definition.
OBJECT-TYPE    
  CxMcVoxLclExtOpeEntry  

cxMcVoxLclExtOpeIndex 1.3.6.1.4.1.495.2.1.1.2.27.1.1
Displays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none
OBJECT-TYPE    
  INTEGER 1..64  

cxMcVoxLclExtOpeExt 1.3.6.1.4.1.495.2.1.1.2.27.1.2
Determines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operational
OBJECT-TYPE    
  DisplayString SIZE(1..5)  

cxMcVoxLclExtOpeHuntChnl 1.3.6.1.4.1.495.2.1.1.2.27.1.3
Defines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value acts as a mask so that all specified channels are polled until the call is accepted. This hunt channel mask includes a maximum of 30 voice channels. The default value includes all local voice channels. If you want to exclude specific channels, calculate the value by following these steps: 1. Decide which ports to include, for example, 1,5,8,29. 2. Convert the list of ports to a series of bits. Start with a list of 30 zeros. 00 0000 0000 0000 0000 0000 0000 0000 To include ports 1, 5, 8, and 29, place 1s in these positions. Numbering starts at 1 at the extreme right. 01 0000 0000 0000 0000 0000 1001 0001 3. Convert this number to hexadecimal. 10000091 4. Convert this number to decimal. 268 435 601 Range of Values: 1 to 1073741823 Default Value: 1073741823 Configuration Changed: operational
OBJECT-TYPE    
  INTEGER 1..1073741823  

cxMcVoxRegenOpe 1.3.6.1.4.1.495.2.1.1.2.28
OBJECT IDENTIFIER    

cxMcVoxRegenOpeExt 1.3.6.1.4.1.495.2.1.1.2.28.1
The RegenOpeExt is used to specify if the local extension tones are to be regenerated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxRegenOpeGid 1.3.6.1.4.1.495.2.1.1.2.28.2
The RegenOpeGid is used to specify if the group ids tones are to be regenerated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxRegenOpeNbDigits 1.3.6.1.4.1.495.2.1.1.2.28.3
The number of digits to be regenerated.
OBJECT-TYPE    
  INTEGER 1..8  

cxMcVoxRegenOpeExtBitMask 1.3.6.1.4.1.495.2.1.1.2.28.4
This object is a bitmap that selects up to cxMcVoxRegenOpeNbDigits, which can be set up to 8 digits, corresponding to a bit that is set. The default value corresponds to 7 (or 00000111 in binary). Range of Values: 0 to 255 Default Value: 7
OBJECT-TYPE    
  INTEGER 0..255  

cxMcVoxTranslOpe 1.3.6.1.4.1.495.2.1.1.2.29
OBJECT IDENTIFIER    

cxMcVoxTranslOpeCntryCodeEnable 1.3.6.1.4.1.495.2.1.1.2.29.1
This specifies whether to translate the local country code.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxTranslOpeCntryCode 1.3.6.1.4.1.495.2.1.1.2.29.2
Displays the number of the operational local country code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none.
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxTranslOpeCntryCodeLng 1.3.6.1.4.1.495.2.1.1.2.29.3
Displays the length (in digits) of the operational local country code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxTranslOpeCCPrefix 1.3.6.1.4.1.495.2.1.1.2.29.4
Displays the number of the operational local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxTranslOpeCCPrefixLng 1.3.6.1.4.1.495.2.1.1.2.29.5
Displays the length (in digits) of the operational non local country code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxTranslOpeAreaCodeEnable 1.3.6.1.4.1.495.2.1.1.2.29.6
This specifies whether to translate the local area code.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxTranslOpeAreaCode 1.3.6.1.4.1.495.2.1.1.2.29.7
Displays the number of the operational local area code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxTranslOpeAreaCodeLng 1.3.6.1.4.1.495.2.1.1.2.29.8
Displays the length (in digits) of the operational local area code. Range of Values: 1 to 4. Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxTranslOpeACPrefix 1.3.6.1.4.1.495.2.1.1.2.29.9
Displays the number of the operational local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxTranslOpeACPrefixLng 1.3.6.1.4.1.495.2.1.1.2.29.10
Displays the length (in digits) of the operational non local area code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxTranslOpeZoneCodeEnable 1.3.6.1.4.1.495.2.1.1.2.29.11
This specifies whether to translate the local zone code.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cxMcVoxTranslOpeZCPrefix 1.3.6.1.4.1.495.2.1.1.2.29.12
Displays the number of the operational local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxTranslOpeZCPrefixLng 1.3.6.1.4.1.495.2.1.1.2.29.13
Displays the length (in digits) of the operational non local zone code. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxHistoryTable 1.3.6.1.4.1.495.2.1.1.2.30
OnLine/OffLine history table for incoming/outgoing calls.
OBJECT-TYPE    
  SEQUENCE OF  
    CxMcVoxHistoryEntry

cxMcVoxHistoryEntry 1.3.6.1.4.1.495.2.1.1.2.30.1
Online/Offline history row definition.
OBJECT-TYPE    
  CxMcVoxHistoryEntry  

cxMcVoxHistoryIndex 1.3.6.1.4.1.495.2.1.1.2.30.1.1
The index number of the history log.
OBJECT-TYPE    
  INTEGER 1..256  

cxMcVoxHistoryLclCardNumber 1.3.6.1.4.1.495.2.1.1.2.30.1.2
Displays the voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind the CPU card and card number 2 is one slot up. In the case of the CX900 product, this card number represents the logical slot corresponding to its physical slot as mapped in the 'voxcard' table. You cannot modify this object. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxHistoryLclPortNumber 1.3.6.1.4.1.495.2.1.1.2.30.1.3
Displays the number of the voice I/O port. You cannot modify this object. Range of Values: 1 to 15 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxHistoryRmtCardNumber 1.3.6.1.4.1.495.2.1.1.2.30.1.4
Displays the remote voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind th You cannot modify this object. Range of Values: 1 to 4 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4  

cxMcVoxHistoryRmtPortNumber 1.3.6.1.4.1.495.2.1.1.2.30.1.5
Displays the number of the voice I/O port that was reached at the remote location. You cannot modify this object. Range of Values: 1 to 15 Default Value: none
OBJECT-TYPE    
  INTEGER 1..15  

cxMcVoxHistoryTimeStampOnLine 1.3.6.1.4.1.495.2.1.1.2.30.1.6
Displays the time stamp of the last on-line event. An on-line event is any incoming or outgoing call that is started. The time stamp indicates the number of seconds elapsed since the last power up. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxHistoryTimeStampOffLine 1.3.6.1.4.1.495.2.1.1.2.30.1.7
Displays the time stamp of the last off-line event. An off-line event is any incoming or outgoing call that the voice station terminates. The time stamp indicates the number of seconds elapsed since the last power up. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none
OBJECT-TYPE    
  INTEGER 1..4294967295  

cxMcVoxHistoryLnkState 1.3.6.1.4.1.495.2.1.1.2.30.1.8
Displays the status of the link to the remote user. When the call is successful the status is either 'Incoming' or 'Outgoing'. Else the error type is displayed. You cannot modify this object. Options: Connection established: either 'Incoming' or 'Outgoing' Local port unavailable: 'LclPortUnavail' Remote extension unavailable: 'RmtExtUnavail' Remote ports busy: 'RmtPortsBusy' Invalid PIN: 'InvalidPIN' Call aborted: 'CallAborted' Default Value: 'CallAborted'
OBJECT-TYPE    
  DisplayString SIZE(1..16)  

cxMcVoxHistoryPin 1.3.6.1.4.1.495.2.1.1.2.30.1.9
Displays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digits, each number from 0 to 9 Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(2..8)  

cxMcVoxHistoryExtensionOrGrpId 1.3.6.1.4.1.495.2.1.1.2.30.1.10
Displays the extension or group ID the remote user has dialed to reach the local user. This object is irrelevant for outgoing calls. You cannot modify this object. Range of Values: 1 to 4 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..4)  

cxMcVoxHistoryPhoneNumber 1.3.6.1.4.1.495.2.1.1.2.30.1.11
For outgoing calls, this object displays the complete phone number (including any voice mail digits) the user entered to reach the remote user. This can include access code, country code, area code and zone code but excludes PIN number. For incoming calls, this object displays either the regenerated code or the translated code (or both). Codes that are dialed after the extension or group ID are also logged in this object both for outgoing and incoming calls. You cannot modify this object. Range of Values: 1 to 24 numeric digits Default Value: none
OBJECT-TYPE    
  DisplayString SIZE(1..24)  

Defined Objects

CxMcVoxCfgEntry  
SEQUENCE    
  INTEGER as cxMcVoxCfgCardIndex  
  INTEGER as cxMcVoxCfgPortIndex  
  INTEGER as cxMcVoxCfgDriverAdmUsed  
  INTEGER as cxMcVoxCfgDriverOpeUsed  
  INTEGER as cxMcVoxCfgTrapOnLine  
  INTEGER as cxMcVoxCfgTrapOffLine  
  INTEGER as cxMcVoxCfgTrapStatus  
  INTEGER as cxMcVoxCfgTrapState  
  INTEGER as cxMcVoxCfgTestPort  
  INTEGER as cxMcVoxCfgToneTest  
  INTEGER as cxMcVoxCfgReinitPort  
  INTEGER as cxMcVoxCfgClearPort  
  DisplayString as cxMcVoxCfgOpeAcelpRev  
  INTEGER as cxMcVoxCfgCmdImmTest  
  INTEGER as cxMcVoxCfgCmdTest  
  INTEGER as cxMcVoxCfgMaxPktFrame  
  INTEGER as cxMcVoxCfgMaxSkew  

CxMcVoxStatusEntry  
SEQUENCE    
  INTEGER as cxMcVoxStatusCardNumber  
  INTEGER as cxMcVoxStatusPortNumber  
  INTEGER as cxMcVoxStatusPortStatus  
  INTEGER as cxMcVoxStatusHookLocal  
  INTEGER as cxMcVoxStatusHookRem  
  INTEGER as cxMcVoxStatusIoAccess  
  INTEGER as cxMcVoxStatusChannelAccess  
  INTEGER as cxMcVoxStatusDspRam  
  INTEGER as cxMcVoxStatusDspDpram  
  INTEGER as cxMcVoxStatusSamplingTime  
  INTEGER as cxMcVoxStatusWatchdog  
  INTEGER as cxMcVoxStatusRemPortStatus  
  INTEGER as cxMcVoxStatusInputDbmLevel  
  INTEGER as cxMcVoxStatusDspUtilization  
  INTEGER as cxMcVoxStatusPhyIfType  
  INTEGER as cxMcVoxStatusIOResetState  

CxMcVoxEventEntry  
SEQUENCE    
  INTEGER as cxMcVoxEventCardNumber  
  INTEGER as cxMcVoxEventPortNumber  
  INTEGER as cxMcVoxEventLogIndex  
  DisplayString as cxMcVoxEventDateAndTimeOnLine  
  DisplayString as cxMcVoxEventDateAndTimeOffLine  
  DisplayString as cxMcVoxEventPhoneNumber  
  INTEGER as cxMcVoxEventLnkState  
  DisplayString as cxMcVoxEventPin  
  INTEGER as cxMcVoxEventClrEvts  

CxMcVoxStateEntry  
SEQUENCE    
  INTEGER as cxMcVoxStateCardNumber  
  INTEGER as cxMcVoxStatePortNumber  
  INTEGER as cxMcVoxStateLogIndex  
  DisplayString as cxMcVoxStatePathId  
  DisplayString as cxMcVoxStateDateAndTime  
  INTEGER as cxMcVoxStateLnkState  
  DisplayString as cxMcVoxStateRmtExt  

CxMcVoxPathAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxPathAdmIndex  
  INTEGER as cxMcVoxPathAdmRowStatus  
  DisplayString as cxMcVoxPathAdmPathId  
  DisplayString as cxMcVoxPathAdmRemStationId  
  INTEGER as cxMcVoxPathAdmHunt  
  INTEGER as cxMcVoxPathAdmLng  

CxMcVoxPathOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxPathOpeIndex  
  DisplayString as cxMcVoxPathOpePathId  
  DisplayString as cxMcVoxPathOpeRemStationId  
  INTEGER as cxMcVoxPathOpeHunt  
  INTEGER as cxMcVoxPathOpeLng  

CxMcVoxNetAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxNetAdmIndex  
  INTEGER as cxMcVoxNetAdmRowStatus  
  DisplayString as cxMcVoxNetAdmRemStationId  
  INTEGER as cxMcVoxNetAdmLocalLnkStation  
  INTEGER as cxMcVoxNetAdmRoute  
  INTEGER as cxMcVoxNetAdmRemVoxStation  

CxMcVoxNetOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxNetOpeIndex  
  DisplayString as cxMcVoxNetOpeRemStationId  
  INTEGER as cxMcVoxNetOpeLocalLnkStation  
  INTEGER as cxMcVoxNetOpeRoute  
  INTEGER as cxMcVoxNetOpeRemVoxStation  

CxMcVoxEmAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxEmAdmCardUsed  
  INTEGER as cxMcVoxEmAdmPortUsed  
  INTEGER as cxMcVoxEmAdmPortStatus  
  INTEGER as cxMcVoxEmAdmVocoder  
  INTEGER as cxMcVoxEmAdmFaxBw  
  INTEGER as cxMcVoxEmAdmAutoCnx  
  DisplayString as cxMcVoxEmAdmPathId  
  INTEGER as cxMcVoxEmAdmTxGain  
  INTEGER as cxMcVoxEmAdmRxGain  
  INTEGER as cxMcVoxEmAdmEchoCancel  
  INTEGER as cxMcVoxEmAdmType  
  INTEGER as cxMcVoxEmAdmMode  
  INTEGER as cxMcVoxEmAdmDialType  
  INTEGER as cxMcVoxEmAdmSignalType  
  INTEGER as cxMcVoxEmAdmAc15Type  
  INTEGER as cxMcVoxEmAdmAc15TimeOn  
  INTEGER as cxMcVoxEmAdmAc15TimeOff  
  INTEGER as cxMcVoxEmAdmCnctType  
  INTEGER as cxMcVoxEmAdmRingType  
  DisplayString as cxMcVoxEmAdmRmtExt  
  DisplayString as cxMcVoxEmAdmRmtId  
  INTEGER as cxMcVoxEmAdmTranspMode  
  INTEGER as cxMcVoxEmAdmFaxEnable  
  INTEGER as cxMcVoxEmAdmBroadcast  
  INTEGER as cxMcVoxEmAdmImpedance  
  INTEGER as cxMcVoxEmAdmVoiceConnection  

CxMcVoxFxsAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxFxsAdmCardUsed  
  INTEGER as cxMcVoxFxsAdmPortUsed  
  INTEGER as cxMcVoxFxsAdmPortStatus  
  INTEGER as cxMcVoxFxsAdmVocoder  
  INTEGER as cxMcVoxFxsAdmFaxBw  
  INTEGER as cxMcVoxFxsAdmAutoCnx  
  DisplayString as cxMcVoxFxsAdmPathId  
  INTEGER as cxMcVoxFxsAdmTxGain  
  INTEGER as cxMcVoxFxsAdmRxGain  
  INTEGER as cxMcVoxFxsAdmEchoCancel  
  INTEGER as cxMcVoxFxsAdmSignaling  
  INTEGER as cxMcVoxFxsAdmTimeOn  
  INTEGER as cxMcVoxFxsAdmTimeOff  
  INTEGER as cxMcVoxFxsAdmCnctType  
  INTEGER as cxMcVoxFxsAdmRingType  
  INTEGER as cxMcVoxFxsAdmImpedance  
  INTEGER as cxMcVoxFxsAdmDialType  
  INTEGER as cxMcVoxFxsAdmDidSignalType  
  DisplayString as cxMcVoxFxsAdmRmtExt  
  DisplayString as cxMcVoxFxsAdmRmtId  
  INTEGER as cxMcVoxFxsAdmTranspMode  
  INTEGER as cxMcVoxFxsAdmFaxEnable  
  INTEGER as cxMcVoxFxsAdmBroadcast  

CxMcVoxFxoAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxFxoAdmCardUsed  
  INTEGER as cxMcVoxFxoAdmPortUsed  
  INTEGER as cxMcVoxFxoAdmPortStatus  
  INTEGER as cxMcVoxFxoAdmVocoder  
  INTEGER as cxMcVoxFxoAdmFaxBw  
  INTEGER as cxMcVoxFxoAdmAutoCnx  
  DisplayString as cxMcVoxFxoAdmPathId  
  INTEGER as cxMcVoxFxoAdmTxGain  
  INTEGER as cxMcVoxFxoAdmRxGain  
  INTEGER as cxMcVoxFxoAdmEchoCancel  
  INTEGER as cxMcVoxFxoAdmSignaling  
  INTEGER as cxMcVoxFxoAdmCnctType  
  INTEGER as cxMcVoxFxoAdmRingType  
  INTEGER as cxMcVoxFxoAdmImpedance  
  INTEGER as cxMcVoxFxoAdmDialType  
  INTEGER as cxMcVoxFxoAdmDidSignalType  
  DisplayString as cxMcVoxFxoAdmRmtExt  
  DisplayString as cxMcVoxFxoAdmRmtId  
  INTEGER as cxMcVoxFxoAdmTranspMode  
  INTEGER as cxMcVoxFxoAdmFaxEnable  
  INTEGER as cxMcVoxFxoAdmBroadcast  

CxMcVoxEmOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxEmOpeCardUsed  
  INTEGER as cxMcVoxEmOpePortUsed  
  INTEGER as cxMcVoxEmOpePortStatus  
  INTEGER as cxMcVoxEmOpeVocoder  
  INTEGER as cxMcVoxEmOpeFaxBw  
  INTEGER as cxMcVoxEmOpeAutoCnx  
  DisplayString as cxMcVoxEmOpePathId  
  INTEGER as cxMcVoxEmOpeTxGain  
  INTEGER as cxMcVoxEmOpeRxGain  
  INTEGER as cxMcVoxEmOpeEchoCancel  
  INTEGER as cxMcVoxEmOpeType  
  INTEGER as cxMcVoxEmOpeMode  
  INTEGER as cxMcVoxEmOpeDialType  
  INTEGER as cxMcVoxEmOpeSignalType  
  INTEGER as cxMcVoxEmOpeAc15Type  
  INTEGER as cxMcVoxEmOpeAc15TimeOn  
  INTEGER as cxMcVoxEmOpeAc15TimeOff  
  INTEGER as cxMcVoxEmOpeCnctType  
  INTEGER as cxMcVoxEmOpeRingType  
  DisplayString as cxMcVoxEmOpeRmtExt  
  DisplayString as cxMcVoxEmOpeRmtId  
  INTEGER as cxMcVoxEmOpeTranspMode  
  INTEGER as cxMcVoxEmOpeFaxEnable  
  INTEGER as cxMcVoxEmOpeBroadcast  
  INTEGER as cxMcVoxEmOpeImpedance  
  INTEGER as cxMcVoxEmOpeVoiceConnection  

CxMcVoxFxsOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxFxsOpeCardUsed  
  INTEGER as cxMcVoxFxsOpePortUsed  
  INTEGER as cxMcVoxFxsOpePortStatus  
  INTEGER as cxMcVoxFxsOpeVocoder  
  INTEGER as cxMcVoxFxsOpeFaxBw  
  INTEGER as cxMcVoxFxsOpeAutoCnx  
  DisplayString as cxMcVoxFxsOpePathId  
  INTEGER as cxMcVoxFxsOpeTxGain  
  INTEGER as cxMcVoxFxsOpeRxGain  
  INTEGER as cxMcVoxFxsOpeEchoCancel  
  INTEGER as cxMcVoxFxsOpeSignaling  
  INTEGER as cxMcVoxFxsOpeTimeOn  
  INTEGER as cxMcVoxFxsOpeTimeOff  
  INTEGER as cxMcVoxFxsOpeCnctType  
  INTEGER as cxMcVoxFxsOpeRingType  
  INTEGER as cxMcVoxFxsOpeImpedance  
  INTEGER as cxMcVoxFxsOpeDialType  
  INTEGER as cxMcVoxFxsOpeDidSignalType  
  DisplayString as cxMcVoxFxsOpeRmtExt  
  DisplayString as cxMcVoxFxsOpeRmtId  
  INTEGER as cxMcVoxFxsOpeTranspMode  
  INTEGER as cxMcVoxFxsOpeFaxEnable  
  INTEGER as cxMcVoxFxsOpeBroadcast  

CxMcVoxFxoOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxFxoOpeCardUsed  
  INTEGER as cxMcVoxFxoOpePortUsed  
  INTEGER as cxMcVoxFxoOpePortStatus  
  INTEGER as cxMcVoxFxoOpeVocoder  
  INTEGER as cxMcVoxFxoOpeFaxBw  
  INTEGER as cxMcVoxFxoOpeAutoCnx  
  DisplayString as cxMcVoxFxoOpePathId  
  INTEGER as cxMcVoxFxoOpeTxGain  
  INTEGER as cxMcVoxFxoOpeRxGain  
  INTEGER as cxMcVoxFxoOpeEchoCancel  
  INTEGER as cxMcVoxFxoOpeSignaling  
  INTEGER as cxMcVoxFxoOpeCnctType  
  INTEGER as cxMcVoxFxoOpeRingType  
  INTEGER as cxMcVoxFxoOpeImpedance  
  INTEGER as cxMcVoxFxoOpeDialType  
  INTEGER as cxMcVoxFxoOpeDidSignalType  
  DisplayString as cxMcVoxFxoOpeRmtExt  
  DisplayString as cxMcVoxFxoOpeRmtId  
  INTEGER as cxMcVoxFxoOpeTranspMode  
  INTEGER as cxMcVoxFxoOpeFaxEnable  
  INTEGER as cxMcVoxFxoOpeBroadcast  

CxMcVoxAdmPortPrivEntry  
SEQUENCE    
  INTEGER as cxMcVoxAdmCardUsed  
  INTEGER as cxMcVoxAdmPortUsed  
  INTEGER as cxMcVoxAdmRingTimeOn  
  INTEGER as cxMcVoxAdmRingTimeOff1  
  INTEGER as cxMcVoxAdmRingTimeOff2  
  INTEGER as cxMcVoxAdmEchoCancelLevel  
  INTEGER as cxMcVoxAdmToneDelayAfterCnct  
  INTEGER as cxMcVoxAdmToneDelayAfterFlash  
  INTEGER as cxMcVoxAdmToneOffsetTxGain  
  INTEGER as cxMcVoxAdmVoiceOffsetTxGain  
  INTEGER as cxMcVoxAdmAc15InterDigit  
  INTEGER as cxMcVoxAdmMfToneThold  
  INTEGER as cxMcVoxAdmPulseTmin  
  INTEGER as cxMcVoxAdmPulseTmax  
  INTEGER as cxMcVoxAdmPulseInterDigit  
  INTEGER as cxMcVoxAdmDtmfGuard  
  INTEGER as cxMcVoxAdmDtmfOpeLevel  
  INTEGER as cxMcVoxAdmDtmfTxTimeOn  
  INTEGER as cxMcVoxAdmDtmfTxTimeOff  
  INTEGER as cxMcVoxAdmFlashTmin  
  INTEGER as cxMcVoxAdmFlashTmax  
  INTEGER as cxMcVoxAdmFlashTgen  
  INTEGER as cxMcVoxAdmAfterToneSilences  
  INTEGER as cxMcVoxAdmFaxTxGain  
  INTEGER as cxMcVoxAdmFaxRxGain  
  INTEGER as cxMcVoxAdmFaxHdlcFlags  
  INTEGER as cxMcVoxAdmFaxPreambleDuration  
  INTEGER as cxMcVoxAdmFaxPreambleDelay  
  INTEGER as cxMcVoxAdmFaxCedToneDuration  
  INTEGER as cxMcVoxAdmFaxInterProtoGap  
  INTEGER as cxMcVoxAdmFaxTimerDetectSync  
  INTEGER as cxMcVoxAdmFaxTimerWaitId  
  INTEGER as cxMcVoxAdmFaxMinPreambleDur  
  INTEGER as cxMcVoxAdmFaxMaxPreambleDur  
  INTEGER as cxMcVoxAdmFaxMinPreambleDly  
  INTEGER as cxMcVoxAdmFaxMaxPreambleDly  
  INTEGER as cxMcVoxAdmFaxCedToneDetection  
  INTEGER as cxMcVoxAdmFaxCedMinToneDur  
  INTEGER as cxMcVoxAdmFaxCedMaxToneDur  
  INTEGER as cxMcVoxAdmFaxMaxHdlcFlags  

CxMcVoxOpePortPrivEntry  
SEQUENCE    
  INTEGER as cxMcVoxOpeCardUsed  
  INTEGER as cxMcVoxOpePortUsed  
  INTEGER as cxMcVoxOpeRingTimeOn  
  INTEGER as cxMcVoxOpeRingTimeOff1  
  INTEGER as cxMcVoxOpeRingTimeOff2  
  INTEGER as cxMcVoxOpeEchoCancelLevel  
  INTEGER as cxMcVoxOpeToneDelayAfterCnct  
  INTEGER as cxMcVoxOpeToneDelayAfterFlash  
  INTEGER as cxMcVoxOpeToneOffsetTxGain  
  INTEGER as cxMcVoxOpeVoiceOffsetTxGain  
  INTEGER as cxMcVoxOpeAc15InterDigit  
  INTEGER as cxMcVoxOpeMfToneThold  
  INTEGER as cxMcVoxOpePulseTmin  
  INTEGER as cxMcVoxOpePulseTmax  
  INTEGER as cxMcVoxOpePulseInterDigit  
  INTEGER as cxMcVoxOpeDtmfGuard  
  INTEGER as cxMcVoxOpeDtmfOpeLevel  
  INTEGER as cxMcVoxOpeDtmfTxTimeOn  
  INTEGER as cxMcVoxOpeDtmfTxTimeOff  
  INTEGER as cxMcVoxOpeFlashTmin  
  INTEGER as cxMcVoxOpeFlashTmax  
  INTEGER as cxMcVoxOpeFlashTgen  
  INTEGER as cxMcVoxOpeAfterToneSilences  
  INTEGER as cxMcVoxOpeFaxTxGain  
  INTEGER as cxMcVoxOpeFaxRxGain  
  INTEGER as cxMcVoxOpeFaxHdlcFlags  
  INTEGER as cxMcVoxOpeFaxPreambleDuration  
  INTEGER as cxMcVoxOpeFaxPreambleDelay  
  INTEGER as cxMcVoxOpeFaxCedToneDuration  
  INTEGER as cxMcVoxOpeFaxInterProtoGap  
  INTEGER as cxMcVoxOpeFaxTimerDetectSync  
  INTEGER as cxMcVoxOpeFaxTimerWaitId  
  INTEGER as cxMcVoxOpeFaxMinPreambleDur  
  INTEGER as cxMcVoxOpeFaxMaxPreambleDur  
  INTEGER as cxMcVoxOpeFaxMinPreambleDly  
  INTEGER as cxMcVoxOpeFaxMaxPreambleDly  
  INTEGER as cxMcVoxOpeFaxCedToneDetection  
  INTEGER as cxMcVoxOpeFaxCedMinToneDur  
  INTEGER as cxMcVoxOpeFaxCedMaxToneDur  
  INTEGER as cxMcVoxOpeFaxMaxHdlcFlags  

CxMcVoxOpeTimerPrivEntry  
SEQUENCE    
  INTEGER as cxMcVoxOpeInterfaceType  
  INTEGER as cxMcVoxOpeTimeSeizeIn  
  INTEGER as cxMcVoxOpeTimeWaitDialOut  
  INTEGER as cxMcVoxOpeTimeWaitDialIn  
  INTEGER as cxMcVoxOpeTimeDialOut  
  INTEGER as cxMcVoxOpeTimeDialIn  
  INTEGER as cxMcVoxOpeTimeSiOff  
  INTEGER as cxMcVoxOpeTimeProceed  
  INTEGER as cxMcVoxOpeTimeAnswer  
  INTEGER as cxMcVoxOpeTimeBeforeToneOff  
  INTEGER as cxMcVoxOpeTimeWinkStartIn  
  INTEGER as cxMcVoxOpeTimeWinkStartOut  
  INTEGER as cxMcVoxOpeTimeWinkMin  
  INTEGER as cxMcVoxOpeTimeWinkMax  
  INTEGER as cxMcVoxOpeTimeSeize  
  INTEGER as cxMcVoxOpeTimeDial  
  INTEGER as cxMcVoxOpeTimeOffIn  
  INTEGER as cxMcVoxOpeTimeSiOn  
  INTEGER as cxMcVoxOpeTimeOffOut  
  INTEGER as cxMcVoxOpeTimeDiscIn  
  INTEGER as cxMcVoxOpeTimeDiscOut  
  INTEGER as cxMcVoxOpeTimeToneOut  

CxMcVoxGrpIdAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxGrpIdAdmIndex  
  DisplayString as cxMcVoxGrpIdAdm  
  INTEGER as cxMcVoxGrpIdLenAdm  
  INTEGER as cxMcVoxGrpIdAdmRowStatus  
  INTEGER as cxMcVoxGrpIdAdmNbPoll  

CxMcVoxGrpIdOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxGrpIdOpeIndex  
  DisplayString as cxMcVoxGrpIdOpe  
  INTEGER as cxMcVoxGrpIdLenOpe  
  INTEGER as cxMcVoxGrpIdOpeNbPoll  

CxMcVoxGrpDefAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxGrpDefAdmIndex  
  INTEGER as cxMcVoxGrpDefAdmPriority  
  INTEGER as cxMcVoxGrpDefAdmRowStatus  
  DisplayString as cxMcVoxGrpDefAdmPathId  
  DisplayString as cxMcVoxGrpDefAdmRmtExt  

CxMcVoxGrpDefOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxGrpDefOpeIndex  
  INTEGER as cxMcVoxGrpDefOpePriority  
  DisplayString as cxMcVoxGrpDefOpePathId  
  DisplayString as cxMcVoxGrpDefOpeRmtExt  

CxMcVoxAdmPinEntry  
SEQUENCE    
  INTEGER as cxMcVoxAdmPinIndex  
  DisplayString as cxMcVoxAdmPinCode  
  INTEGER as cxMcVoxAdmPinRowStatus  

CxMcVoxOpePinEntry  
SEQUENCE    
  INTEGER as cxMcVoxOpePinIndex  
  DisplayString as cxMcVoxOpePinCode  

CxMcVoxAdmLclZoneEntry  
SEQUENCE    
  INTEGER as cxMcVoxAdmLclZoneIndex  
  DisplayString as cxMcVoxAdmLclZoneCode  
  INTEGER as cxMcVoxAdmLclZoneLng  
  INTEGER as cxMcVoxAdmLclZoneRowStatus  

CxMcVoxOpeLclZoneEntry  
SEQUENCE    
  INTEGER as cxMcVoxOpeLclZoneIndex  
  DisplayString as cxMcVoxOpeLclZoneCode  
  INTEGER as cxMcVoxOpeLclZoneLng  

CxMcVoxDiagEntry  
SEQUENCE    
  INTEGER as cxMcVoxDiagCardIndex  
  INTEGER as cxMcVoxDiagPortIndex  
  INTEGER as cxMcVoxDiagScvEvents  
  INTEGER as cxMcVoxDiagGsdEvents  
  INTEGER as cxMcVoxDiagToneInEvents  
  INTEGER as cxMcVoxDiagToneOutEvents  
  INTEGER as cxMcVoxDiagFaxInEvents  
  INTEGER as cxMcVoxDiagFaxOutEvents  
  INTEGER as cxMcVoxDiagGlmEvents  
  INTEGER as cxMcVoxDiagIbvDiags  
  INTEGER as cxMcVoxDiagPcvDiags  
  INTEGER as cxMcVoxDiagGcvDiags  
  INTEGER as cxMcVoxDiagFaxDiags  
  INTEGER as cxMcVoxDiagLseDiags  
  INTEGER as cxMcVoxDiagScvDiags  
  INTEGER as cxMcVoxDiagGlmDiags  

CxMcVoxLclExtAdmEntry  
SEQUENCE    
  INTEGER as cxMcVoxLclExtAdmIndex  
  INTEGER as cxMcVoxLclExtAdmRowStatus  
  DisplayString as cxMcVoxLclExtAdmExt  
  INTEGER as cxMcVoxLclExtAdmHuntChnl  

CxMcVoxLclExtOpeEntry  
SEQUENCE    
  INTEGER as cxMcVoxLclExtOpeIndex  
  DisplayString as cxMcVoxLclExtOpeExt  
  INTEGER as cxMcVoxLclExtOpeHuntChnl  

CxMcVoxHistoryEntry  
SEQUENCE    
  INTEGER as cxMcVoxHistoryIndex  
  INTEGER as cxMcVoxHistoryLclCardNumber  
  INTEGER as cxMcVoxHistoryLclPortNumber  
  INTEGER as cxMcVoxHistoryRmtCardNumber  
  INTEGER as cxMcVoxHistoryRmtPortNumber  
  INTEGER as cxMcVoxHistoryTimeStampOnLine  
  INTEGER as cxMcVoxHistoryTimeStampOffLine  
  DisplayString as cxMcVoxHistoryLnkState  
  DisplayString as cxMcVoxHistoryPin  
  DisplayString as cxMcVoxHistoryExtensionOrGrpId  
  DisplayString as cxMcVoxHistoryPhoneNumber