DATA-DOMAIN-MIB

File: DATA-DOMAIN-MIB.mib (69827 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF RFC1155-SMI
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
Counter32 Counter64 enterprises
DisplayString

Defined Objects

dataDomainMib 1.3.6.1.4.1.19746
This MIB is used for managing the suite of Data Domain Products.
MODULE-IDENTITY    

dataDomainMibConformance 1.3.6.1.4.1.19746.0
OBJECT IDENTIFIER    

dataDomainMibCompliances 1.3.6.1.4.1.19746.0.1
OBJECT IDENTIFIER    

dataDomainMibCompliance 1.3.6.1.4.1.19746.0.1.1
The compliance statement for SNMP entities which implement this MIB module.
MODULE-COMPLIANCE    

dataDomainMibGroups 1.3.6.1.4.1.19746.0.2
OBJECT IDENTIFIER    

environmentalsGroup 1.3.6.1.4.1.19746.0.2.1
A collection of objects providing environmental monitoring information.
OBJECT-GROUP    

nvramGroup 1.3.6.1.4.1.19746.0.2.2
A collection of objects providing nvram monitoring information.
OBJECT-GROUP    

fileSystemGroup 1.3.6.1.4.1.19746.0.2.3
A collection of objects providing file system monitoring information.
OBJECT-GROUP    

alertsGroup 1.3.6.1.4.1.19746.0.2.4
A collection of objects providing alert monitoring information.
OBJECT-GROUP    

statisticsGroup 1.3.6.1.4.1.19746.0.2.5
A collection of objects providing statistics information.
OBJECT-GROUP    

raidGroup 1.3.6.1.4.1.19746.0.2.6
A collection of objects providing raid monitoring information.
OBJECT-GROUP    

internalDiskStorageGroup 1.3.6.1.4.1.19746.0.2.7
A collection of objects providing internal disk monitoring information.
OBJECT-GROUP    

externalUnmanagedDiskStorageGroup 1.3.6.1.4.1.19746.0.2.8
A collection of objects providing internal disk monitoring information.
OBJECT-GROUP    

basicNotificationsGroup 1.3.6.1.4.1.19746.0.2.9
A collection of objects providing basic notifications.
NOTIFICATION-GROUP    

internalDiskStorageNotificationsGroup 1.3.6.1.4.1.19746.0.2.10
A collection of objects providing internal disk storage notifications.
NOTIFICATION-GROUP    

replGroup 1.3.6.1.4.1.19746.0.2.11
a collection of objects providing replication pair config and monitoring information.
OBJECT-GROUP    

dataDomainMibObjects 1.3.6.1.4.1.19746.1
OBJECT IDENTIFIER    

environmentals 1.3.6.1.4.1.19746.1.1
OBJECT IDENTIFIER    

power 1.3.6.1.4.1.19746.1.1.1
OBJECT IDENTIFIER    

powerModules 1.3.6.1.4.1.19746.1.1.1.1
OBJECT IDENTIFIER    

powerModuleTable 1.3.6.1.4.1.19746.1.1.1.1.1
A table containing entries of PowerModuleEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    PowerModuleEntry

powerModuleEntry 1.3.6.1.4.1.19746.1.1.1.1.1.1
powerModuleTable Row Description
OBJECT-TYPE    
  PowerModuleEntry  

powerEnclosureID 1.3.6.1.4.1.19746.1.1.1.1.1.1.1
Power Module Enclosure ID
OBJECT-TYPE    
  EnclosureID  

powerModuleIndex 1.3.6.1.4.1.19746.1.1.1.1.1.1.2
Power Module index
OBJECT-TYPE    
  PowerModuleIndex  

powerModuleStatus 1.3.6.1.4.1.19746.1.1.1.1.1.1.3
current enclosure Power Module status
OBJECT-TYPE    
  PowerModuleStatus  

temperatures 1.3.6.1.4.1.19746.1.1.2
OBJECT IDENTIFIER    

temperatureSensors 1.3.6.1.4.1.19746.1.1.2.1
OBJECT IDENTIFIER    

temperatureSensorTable 1.3.6.1.4.1.19746.1.1.2.1.1
A table containing entries of TemperatureSensorEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureSensorEntry

temperatureSensorEntry 1.3.6.1.4.1.19746.1.1.2.1.1.1
temperatureSensorTable Row Description
OBJECT-TYPE    
  TemperatureSensorEntry  

tempEnclosureID 1.3.6.1.4.1.19746.1.1.2.1.1.1.1
Temperature Sensor Enclosure ID
OBJECT-TYPE    
  EnclosureID  

tempSensorIndex 1.3.6.1.4.1.19746.1.1.2.1.1.1.2
Temperature Sensor Number
OBJECT-TYPE    
  TempSensorIndex  

tempSensorDescription 1.3.6.1.4.1.19746.1.1.2.1.1.1.3
Temperature Sensor Description
OBJECT-TYPE    
  TempSensorDescription  

tempSensorCurrentValue 1.3.6.1.4.1.19746.1.1.2.1.1.1.4
Current Temperature Value of the sensor
OBJECT-TYPE    
  Temperature  

tempSensorStatus 1.3.6.1.4.1.19746.1.1.2.1.1.1.5
Current status of the sensor
OBJECT-TYPE    
  TempSensorStatus  

fans 1.3.6.1.4.1.19746.1.1.3
OBJECT IDENTIFIER    

fanProperties 1.3.6.1.4.1.19746.1.1.3.1
OBJECT IDENTIFIER    

fanPropertiesTable 1.3.6.1.4.1.19746.1.1.3.1.1
A table containing entries of FanPropertiesEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    FanPropertiesEntry

fanPropertiesEntry 1.3.6.1.4.1.19746.1.1.3.1.1.1
fanPropertiesTable Row Description
OBJECT-TYPE    
  FanPropertiesEntry  

fanEnclosureID 1.3.6.1.4.1.19746.1.1.3.1.1.1.1
Enclosure ID of fan
OBJECT-TYPE    
  EnclosureID  

fanIndex 1.3.6.1.4.1.19746.1.1.3.1.1.1.2
Fan Number
OBJECT-TYPE    
  FanIndex  

fanDescription 1.3.6.1.4.1.19746.1.1.3.1.1.1.3
Vendor supplied description of the fan
OBJECT-TYPE    
  FanDescription  

fanLevel 1.3.6.1.4.1.19746.1.1.3.1.1.1.4
current run level of fan
OBJECT-TYPE    
  FanLevel  

fanStatus 1.3.6.1.4.1.19746.1.1.3.1.1.1.5
Current status of the fan
OBJECT-TYPE    
  FanStatus  

nvram 1.3.6.1.4.1.19746.1.2
OBJECT IDENTIFIER    

nvramProperties 1.3.6.1.4.1.19746.1.2.1
OBJECT IDENTIFIER    

nvramMemorySize 1.3.6.1.4.1.19746.1.2.1.1
Size of NVRAM Memory in megabytes
OBJECT-TYPE    
  NvramMemorySize  

nvramWindowSize 1.3.6.1.4.1.19746.1.2.1.2
Window size of NVRAM in megabytes
OBJECT-TYPE    
  NvramWindowSize  

nvramStats 1.3.6.1.4.1.19746.1.2.2
OBJECT IDENTIFIER    

nvramPCIErrorCount 1.3.6.1.4.1.19746.1.2.2.1
Number of PCI Errors Encountered on NVRAM Card
OBJECT-TYPE    
  ErrorCount  

nvramMemoryErrorCount 1.3.6.1.4.1.19746.1.2.2.2
Number of Memory Errors Encountered on NVRAM Card
OBJECT-TYPE    
  ErrorCount  

nvramBatteries 1.3.6.1.4.1.19746.1.2.3
OBJECT IDENTIFIER    

nvramBatteryTable 1.3.6.1.4.1.19746.1.2.3.1
A table containing entries of NvramBatteryEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    NvramBatteryEntry

nvramBatteryEntry 1.3.6.1.4.1.19746.1.2.3.1.1
nvramBatteryTable Row Description
OBJECT-TYPE    
  NvramBatteryEntry  

nvramBatteryIndex 1.3.6.1.4.1.19746.1.2.3.1.1.1
NVRAM Battery Number
OBJECT-TYPE    
  NvramBatteryIndex  

nvramBatteryStatus 1.3.6.1.4.1.19746.1.2.3.1.1.2
NVRAM Battery Status
OBJECT-TYPE    
  NvramBatteryStatus  

nvramBatteryCharge 1.3.6.1.4.1.19746.1.2.3.1.1.3
NVRAM Battery change percentage
OBJECT-TYPE    
  Percentage  

fileSystem 1.3.6.1.4.1.19746.1.3
OBJECT IDENTIFIER    

fileSystemProperties 1.3.6.1.4.1.19746.1.3.1
OBJECT IDENTIFIER    

fileSystemStatus 1.3.6.1.4.1.19746.1.3.1.1
Status of the file system
OBJECT-TYPE    
  FileSystemStatus  

fileSystemVirtualSpace 1.3.6.1.4.1.19746.1.3.1.2
Amount of Uncompressed data that has been backed up by the system
OBJECT-TYPE    
  FileSystemSpaceUnit  

fileSystemSpace 1.3.6.1.4.1.19746.1.3.2
OBJECT IDENTIFIER    

fileSystemSpaceTable 1.3.6.1.4.1.19746.1.3.2.1
A table containing entries of FileSystemSpaceEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    FileSystemSpaceEntry

fileSystemSpaceEntry 1.3.6.1.4.1.19746.1.3.2.1.1
fileSystemSpaceTable Row Description
OBJECT-TYPE    
  FileSystemSpaceEntry  

fileSystemResourceIndex 1.3.6.1.4.1.19746.1.3.2.1.1.1
File system resource index
OBJECT-TYPE    
  FileSystemResourceIndex  

fileSystemResourceName 1.3.6.1.4.1.19746.1.3.2.1.1.2
File system resource name
OBJECT-TYPE    
  FileSystemResourceName  

fileSystemSpaceSize 1.3.6.1.4.1.19746.1.3.2.1.1.3
Size of the file system resource in gigabytes
OBJECT-TYPE    
  FileSystemSpaceUnit  

fileSystemSpaceUsed 1.3.6.1.4.1.19746.1.3.2.1.1.4
Amount of used space within the file system resource in gigabytes
OBJECT-TYPE    
  FileSystemSpaceUnit  

fileSystemSpaceAvail 1.3.6.1.4.1.19746.1.3.2.1.1.5
Amount of available space within the file system resource in gigabytes
OBJECT-TYPE    
  FileSystemSpaceUnit  

fileSystemPercentUsed 1.3.6.1.4.1.19746.1.3.2.1.1.6
Percentage of used space within the file system resource
OBJECT-TYPE    
  Percentage  

alerts 1.3.6.1.4.1.19746.1.4
OBJECT IDENTIFIER    

currentAlerts 1.3.6.1.4.1.19746.1.4.1
OBJECT IDENTIFIER    

currentAlertTable 1.3.6.1.4.1.19746.1.4.1.1
A table containing entries of CurrentAlertEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    CurrentAlertEntry

currentAlertEntry 1.3.6.1.4.1.19746.1.4.1.1.1
currentAlertTable Row Description
OBJECT-TYPE    
  CurrentAlertEntry  

currentAlertIndex 1.3.6.1.4.1.19746.1.4.1.1.1.1
Current Alert Row index
OBJECT-TYPE    
  AlertIndex  

currentAlertTimestamp 1.3.6.1.4.1.19746.1.4.1.1.1.2
Timestamp of current alert
OBJECT-TYPE    
  AlertTimestamp  

currentAlertDescription 1.3.6.1.4.1.19746.1.4.1.1.1.3
Alert Description
OBJECT-TYPE    
  AlertDescription  

statistics 1.3.6.1.4.1.19746.1.5
OBJECT IDENTIFIER    

systemStats 1.3.6.1.4.1.19746.1.5.1
OBJECT IDENTIFIER    

systemStatsTable 1.3.6.1.4.1.19746.1.5.1.1
A table containing entries of SystemStatsEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    SystemStatsEntry

systemStatsEntry 1.3.6.1.4.1.19746.1.5.1.1.1
systemStatsTable Row Description
OBJECT-TYPE    
  SystemStatsEntry  

systemStatsIndex 1.3.6.1.4.1.19746.1.5.1.1.1.1
System Stats Row index
OBJECT-TYPE    
  SystemStatsIndex  

cpu0PercentageBusy 1.3.6.1.4.1.19746.1.5.1.1.1.2
CPU 0 Percentage Busy
OBJECT-TYPE    
  Percentage  

cpu1PercentageBusy 1.3.6.1.4.1.19746.1.5.1.1.1.3
CPU 1 Percentage Busy
OBJECT-TYPE    
  Percentage  

nfsOpsPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.4
Number of NFS Operations performed per second
OBJECT-TYPE    
  OpsPerSecond  

nfsIdlePercentage 1.3.6.1.4.1.19746.1.5.1.1.1.5
Percentage of time NFS was Idle
OBJECT-TYPE    
  Percentage  

nfsProcPercentage 1.3.6.1.4.1.19746.1.5.1.1.1.6
Percentage of time NFS was processing
OBJECT-TYPE    
  Percentage  

nfsSendPercentage 1.3.6.1.4.1.19746.1.5.1.1.1.7
Percentage of time NFS was sending requests
OBJECT-TYPE    
  Percentage  

nfsReceivePercentage 1.3.6.1.4.1.19746.1.5.1.1.1.8
Percentage of time NFS was receiving requests
OBJECT-TYPE    
  Percentage  

cifsOpsPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.9
Number of CIFS Operations performed per second
OBJECT-TYPE    
  OpsPerSecond  

diskReadKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.10
Number of KBytes per second read from disk
OBJECT-TYPE    
  KBytesPerSecond  

diskWriteKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.11
Number of KBytes per second read from disk
OBJECT-TYPE    
  KBytesPerSecond  

diskBusyPercentage 1.3.6.1.4.1.19746.1.5.1.1.1.12
Percentage of Time Disks were busy
OBJECT-TYPE    
  Percentage  

nvramReadKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.13
Number of KBytes read per second from NVRAM
OBJECT-TYPE    
  KBytesPerSecond  

nvramWriteKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.14
Number of KBytes read per second from NVRAM
OBJECT-TYPE    
  KBytesPerSecond  

replInKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.15
Number of KBytes per second received for Replication
OBJECT-TYPE    
  KBytesPerSecond  

replOutKBytesPerSecond 1.3.6.1.4.1.19746.1.5.1.1.1.16
Number of KBytes per second sent for Replication
OBJECT-TYPE    
  KBytesPerSecond  

diskStorage 1.3.6.1.4.1.19746.1.6
OBJECT IDENTIFIER    

diskProperties 1.3.6.1.4.1.19746.1.6.1
OBJECT IDENTIFIER    

diskPropertiesTable 1.3.6.1.4.1.19746.1.6.1.1
A table containing entries of DiskPropertiesEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    DiskPropertiesEntry

diskPropertiesEntry 1.3.6.1.4.1.19746.1.6.1.1.1
diskPropertiesTable Row Description
OBJECT-TYPE    
  DiskPropertiesEntry  

diskPropEnclosureID 1.3.6.1.4.1.19746.1.6.1.1.1.1
Enclosure ID of disk
OBJECT-TYPE    
  EnclosureID  

diskPropIndex 1.3.6.1.4.1.19746.1.6.1.1.1.2
Disk Number
OBJECT-TYPE    
  DiskIndex  

diskModel 1.3.6.1.4.1.19746.1.6.1.1.1.3
Manufacture and model of the disk
OBJECT-TYPE    
  DiskModel  

diskFirmwareVersion 1.3.6.1.4.1.19746.1.6.1.1.1.4
Firmware version of the disk
OBJECT-TYPE    
  DiskFirmwareVersion  

diskSerialNumber 1.3.6.1.4.1.19746.1.6.1.1.1.5
Serial Number of the disk
OBJECT-TYPE    
  DiskSerialNumber  

diskCapacity 1.3.6.1.4.1.19746.1.6.1.1.1.6
Capacity of the disk
OBJECT-TYPE    
  DiskCapacity  

diskPropState 1.3.6.1.4.1.19746.1.6.1.1.1.7
Current State of the disk
OBJECT-TYPE    
  DiskState  

diskPerformance 1.3.6.1.4.1.19746.1.6.2
OBJECT IDENTIFIER    

diskPerformanceTable 1.3.6.1.4.1.19746.1.6.2.1
A table containing entries of DiskPerformanceEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    DiskPerformanceEntry

diskPerformanceEntry 1.3.6.1.4.1.19746.1.6.2.1.1
diskPerformanceTable Row Description
OBJECT-TYPE    
  DiskPerformanceEntry  

diskPerfEnclosureID 1.3.6.1.4.1.19746.1.6.2.1.1.1
Enclosure ID of disk
OBJECT-TYPE    
  EnclosureID  

diskPerfIndex 1.3.6.1.4.1.19746.1.6.2.1.1.2
Disk Number
OBJECT-TYPE    
  DiskIndex  

diskSectorsRead 1.3.6.1.4.1.19746.1.6.2.1.1.3
Number of disk sectors read per second
OBJECT-TYPE    
  DiskSectorsPerSecond  

diskSectorsWritten 1.3.6.1.4.1.19746.1.6.2.1.1.4
Number of disk sectors written per second
OBJECT-TYPE    
  DiskSectorsPerSecond  

diskTotalKBytes 1.3.6.1.4.1.19746.1.6.2.1.1.5
Total Number of Kilo-bytes read/written per second
OBJECT-TYPE    
  KBytesPerSecond  

diskBusy 1.3.6.1.4.1.19746.1.6.2.1.1.6
Percentage of time disk is busy
OBJECT-TYPE    
  Percentage  

diskPerfState 1.3.6.1.4.1.19746.1.6.2.1.1.7
Current State of the disk
OBJECT-TYPE    
  DiskState  

diskReliability 1.3.6.1.4.1.19746.1.6.3
OBJECT IDENTIFIER    

diskReliabilityTable 1.3.6.1.4.1.19746.1.6.3.1
A table containing entries of DiskReliabilityEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    DiskReliabilityEntry

diskReliabilityEntry 1.3.6.1.4.1.19746.1.6.3.1.1
diskReliabilityTable Row Description
OBJECT-TYPE    
  DiskReliabilityEntry  

diskErrEnclosureID 1.3.6.1.4.1.19746.1.6.3.1.1.1
Enclosure ID of disk
OBJECT-TYPE    
  EnclosureID  

diskErrIndex 1.3.6.1.4.1.19746.1.6.3.1.1.2
Disk Number
OBJECT-TYPE    
  DiskIndex  

diskTemperature 1.3.6.1.4.1.19746.1.6.3.1.1.3
Current Disk Temperature in Celsius
OBJECT-TYPE    
  Temperature  

diskTimeoutCount 1.3.6.1.4.1.19746.1.6.3.1.1.4
Number of command timeouts
OBJECT-TYPE    
  ErrorCount  

diskReadFailCount 1.3.6.1.4.1.19746.1.6.3.1.1.5
Number of read failures
OBJECT-TYPE    
  ErrorCount  

diskWriteFailCount 1.3.6.1.4.1.19746.1.6.3.1.1.6
Number of write failures
OBJECT-TYPE    
  ErrorCount  

diskMiscFailCount 1.3.6.1.4.1.19746.1.6.3.1.1.7
Number of miscellaneous failures
OBJECT-TYPE    
  ErrorCount  

diskOffTrackErrCount 1.3.6.1.4.1.19746.1.6.3.1.1.8
Number of offtrack errors
OBJECT-TYPE    
  ErrorCount  

diskSoftEccCount 1.3.6.1.4.1.19746.1.6.3.1.1.9
Number of soft ecc errors
OBJECT-TYPE    
  ErrorCount  

diskCrcErrCount 1.3.6.1.4.1.19746.1.6.3.1.1.10
Number of crc errors
OBJECT-TYPE    
  ErrorCount  

diskProbationalCount 1.3.6.1.4.1.19746.1.6.3.1.1.11
Number of probational errors
OBJECT-TYPE    
  ErrorCount  

diskReallocCount 1.3.6.1.4.1.19746.1.6.3.1.1.12
Number of reallocation errors
OBJECT-TYPE    
  ErrorCount  

diskErrState 1.3.6.1.4.1.19746.1.6.3.1.1.13
Current State of the disk
OBJECT-TYPE    
  DiskState  

raid 1.3.6.1.4.1.19746.1.7
OBJECT IDENTIFIER    

raidInfo 1.3.6.1.4.1.19746.1.7.1
OBJECT IDENTIFIER    

raidInfoTable 1.3.6.1.4.1.19746.1.7.1.1
A table containing entries of RaidInfoEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    RaidInfoEntry

raidInfoEntry 1.3.6.1.4.1.19746.1.7.1.1.1
raidInfoTable Row Description
OBJECT-TYPE    
  RaidInfoEntry  

raidDiskEnclosureID 1.3.6.1.4.1.19746.1.7.1.1.1.1
Enclosure id of raid disk
OBJECT-TYPE    
  EnclosureID  

raidDiskIndex 1.3.6.1.4.1.19746.1.7.1.1.1.2
Disk Number of raid disk
OBJECT-TYPE    
  DiskIndex  

raidDiskState 1.3.6.1.4.1.19746.1.7.1.1.1.3
State of raid disk
OBJECT-TYPE    
  RaidDiskState  

raidDiskGroup 1.3.6.1.4.1.19746.1.7.1.1.1.4
Disk Group of raid disk
OBJECT-TYPE    
  RaidDiskGroup  

raidDiskStatus 1.3.6.1.4.1.19746.1.7.1.1.1.5
Status of raid disk
OBJECT-TYPE    
  RaidDiskStatus  

raidDiskReconPercentage 1.3.6.1.4.1.19746.1.7.1.1.1.6
Reconstruction Percentage complete if raidDiskStatus = reconstructing
OBJECT-TYPE    
  Percentage  

raidDiskReconMinutes 1.3.6.1.4.1.19746.1.7.1.1.1.7
Number of minutes reconstruction has taken if raidDiskStatus = reconstructing
OBJECT-TYPE    
  Minutes  

raidDiskResynchPercentage 1.3.6.1.4.1.19746.1.7.1.1.1.8
Resynch Percentage complete if raidDiskStatus = resynching
OBJECT-TYPE    
  Percentage  

raidDiskResynchMinutes 1.3.6.1.4.1.19746.1.7.1.1.1.9
Number of minutes resynching has taken if raidDiskStatus = resynching
OBJECT-TYPE    
  Minutes  

replication 1.3.6.1.4.1.19746.1.8
OBJECT IDENTIFIER    

replicationInfo 1.3.6.1.4.1.19746.1.8.1
OBJECT IDENTIFIER    

replicationInfoTable 1.3.6.1.4.1.19746.1.8.1.1
A table containing entries of ReplicationInfoEntry.
OBJECT-TYPE    
  SEQUENCE OF  
    ReplicationInfoEntry

replicationInfoEntry 1.3.6.1.4.1.19746.1.8.1.1.1
replicationInfoTable Row Description
OBJECT-TYPE    
  ReplicationInfoEntry  

replContext 1.3.6.1.4.1.19746.1.8.1.1.1.1
context ID of replication source/dest pair
OBJECT-TYPE    
  ReplicationContext  

replState 1.3.6.1.4.1.19746.1.8.1.1.1.2
state of replication source/dest pair
OBJECT-TYPE    
  ReplicationState  

replStatus 1.3.6.1.4.1.19746.1.8.1.1.1.3
status of replication source/dest pair connection
OBJECT-TYPE    
  ReplicationStatus  

replFileSysStatus 1.3.6.1.4.1.19746.1.8.1.1.1.4
status of filesystem
OBJECT-TYPE    
  FileSystemStatus  

replConnTime 1.3.6.1.4.1.19746.1.8.1.1.1.5
time of connection established between source and dest, or time since disconnect if status is 'disconnected'
OBJECT-TYPE    
  ReplicationConnectTime  

replSource 1.3.6.1.4.1.19746.1.8.1.1.1.6
network path to replication source directory
OBJECT-TYPE    
  ReplicationPath  

replDestination 1.3.6.1.4.1.19746.1.8.1.1.1.7
network path to replication destination directory
OBJECT-TYPE    
  ReplicationPath  

replLag 1.3.6.1.4.1.19746.1.8.1.1.1.8
time lag between source and destination
OBJECT-TYPE    
  ReplicationLag  

replPreCompBytesSent 1.3.6.1.4.1.19746.1.8.1.1.1.9
pre compression bytes sent
OBJECT-TYPE    
  ReplicationTraffic  

replPostCompBytesSent 1.3.6.1.4.1.19746.1.8.1.1.1.10
post compression bytes sent
OBJECT-TYPE    
  ReplicationTraffic  

replPreCompBytesRemaining 1.3.6.1.4.1.19746.1.8.1.1.1.11
pre compression bytes remaining
OBJECT-TYPE    
  ReplicationTraffic  

replPostCompBytesReceived 1.3.6.1.4.1.19746.1.8.1.1.1.12
post compression bytes received
OBJECT-TYPE    
  ReplicationTraffic  

replThrottle 1.3.6.1.4.1.19746.1.8.1.1.1.13
replication throttle in bps -- -1 is disabled, 0 unlimited
OBJECT-TYPE    
  ReplicationThrottle  

replSyncedAsOfTime 1.3.6.1.4.1.19746.1.8.1.1.1.14
time when the source and destination were in sync, or 0 if the time is unknown
OBJECT-TYPE    
  ReplicationSyncedTime  

dataDomainMibNotifications 1.3.6.1.4.1.19746.2
OBJECT IDENTIFIER    

powerSupplyFailedAlarm 1.3.6.1.4.1.19746.2.1
Meaning: Power Supply failed What to do: replace the power supply
NOTIFICATION-TYPE    

systemOverheatWarningAlarm 1.3.6.1.4.1.19746.2.2
Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
NOTIFICATION-TYPE    
  tempSensorIndex  

systemOverheatAlertAlarm 1.3.6.1.4.1.19746.2.3
Meaning: the temperature reading of one of the thermometers in the Chassis is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the system temperature.
NOTIFICATION-TYPE    
  tempSensorIndex  

systemOverheatShutdowntAlarm 1.3.6.1.4.1.19746.2.4
Meaning: the temperature reading of one of the thermometers in the Chassis has reached or exceeded the 'shutdown' temperature level. The DDR will be shutdown to prevent damage to the system. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: Once the system has been brought back up, after checking for high environment temperatures or other factors which may increase the system temperature, check other environmental values, such as Fan Status, Disk Temperatures, etc...
NOTIFICATION-TYPE    
  tempSensorIndex  

fanModuleFailedAlarm 1.3.6.1.4.1.19746.2.5
Meaning: a Fan Module in the enclosure has failed. The index of the fan is given as the index of the alarm. This same index can be looked up in the environmentals table 'fanProperies' for more information about which fan has failed. What to do: replace the fan
NOTIFICATION-TYPE    
  fanIndex  

nvramFailingAlarm 1.3.6.1.4.1.19746.2.6
Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue.
NOTIFICATION-TYPE    

fileSystemFailedAlarm 1.3.6.1.4.1.19746.2.7
Meaning: The File System process on the DDR has had a serious problem and has had to restart. What to do: check the system logs for conditions that may be triggering the failure. Other alarms may also indicate why the File System is having problems.
NOTIFICATION-TYPE    

fileSpaceMaintenanceAlarm 1.3.6.1.4.1.19746.2.8
Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The system may not have enough space for the routine system activities to run without error. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
NOTIFICATION-TYPE    
  fileSystemResourceIndex  

fileSpaceWarningAlarm 1.3.6.1.4.1.19746.2.9
Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
NOTIFICATION-TYPE    
  fileSystemResourceIndex  

fileSpaceSevereAlarm 1.3.6.1.4.1.19746.2.10
Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
NOTIFICATION-TYPE    
  fileSystemResourceIndex  

fileSpaceCriticalAlarm 1.3.6.1.4.1.19746.2.11
Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
NOTIFICATION-TYPE    
  fileSystemResourceIndex  

diskFailingAlarm 1.3.6.1.4.1.19746.2.12
Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk that is failing. What to do: monitor the status of the disk, and consider replacing if the problem continues.
NOTIFICATION-TYPE    
  diskPropIndex  

diskFailedAlarm 1.3.6.1.4.1.19746.2.13
Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk that has failed. What to do: replace the disk.
NOTIFICATION-TYPE    
  diskPropIndex  

diskOverheatWarningAlarm 1.3.6.1.4.1.19746.2.14
Meaning: the temperature reading of the indicated disk has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
NOTIFICATION-TYPE    
  diskErrIndex  

diskOverheatAlertAlarm 1.3.6.1.4.1.19746.2.15
Meaning: the temperature reading of the indicated disk is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it will trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature. If the temperature continues stays at this level or rises, and no other disks are reading this trouble, consider 'failing' the disk, and get a replacement.
NOTIFICATION-TYPE    
  diskErrIndex  

diskOverheatShutdowntAlarm 1.3.6.1.4.1.19746.2.16
Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown' temperature level. The DDR will be shutdown. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: Boot the DDR and monitor the status and temperatures. If the same disk has continued problems, consider 'failing' it and get a replacement disk.
NOTIFICATION-TYPE    
  diskErrIndex  

raidReconSevereAlarm 1.3.6.1.4.1.19746.2.17
Meaning: Raid group reconstruction is currently active and has not completed after 71 hours. Reconstruction occurs when the raid group falls into 'degraded' mode. This can happen due to a disk failing at run-time or boot-up. What to do: while it is still possible that the reconstruction could succeed, the disk should be replaced to ensure data safety.
NOTIFICATION-TYPE    

raidReconCriticalAlarm 1.3.6.1.4.1.19746.2.18
Meaning: Raid group reconstruction is currently active and has not completed after 72 hours. Reconstruction occurs when the raid group falls into 'degraded' mode. This can happen due to a disk failing at run-time or boot-up. What to do: the disk should be replaced to ensure data safety.
NOTIFICATION-TYPE    

raidReconCriticalShutdownAlarm 1.3.6.1.4.1.19746.2.19
Meaning: Raid group reconstruction is currently active and has not completed after more than 72 hours. Reconstruction occurs when the raid group falls into 'degraded' mode. This can happen due to a disk failing at run-time or boot-up. What to do: the disk must be replaced.
NOTIFICATION-TYPE    

products 1.3.6.1.4.1.19746.3
OBJECT IDENTIFIER    

restorer 1.3.6.1.4.1.19746.3.1
OBJECT IDENTIFIER    

dd200 1.3.6.1.4.1.19746.3.1.1
OBJECT IDENTIFIER    

dd200Proto 1.3.6.1.4.1.19746.3.1.2
OBJECT IDENTIFIER    

dd410 1.3.6.1.4.1.19746.3.1.3
OBJECT IDENTIFIER    

dd430 1.3.6.1.4.1.19746.3.1.4
OBJECT IDENTIFIER    

dd460 1.3.6.1.4.1.19746.3.1.5
OBJECT IDENTIFIER    

dd400g 1.3.6.1.4.1.19746.3.1.6
OBJECT IDENTIFIER    

dd460g 1.3.6.1.4.1.19746.3.1.7
OBJECT IDENTIFIER    

dd560 1.3.6.1.4.1.19746.3.1.8
OBJECT IDENTIFIER    

dd560g 1.3.6.1.4.1.19746.3.1.9
OBJECT IDENTIFIER    

dd580 1.3.6.1.4.1.19746.3.1.10
OBJECT IDENTIFIER    

dd580g 1.3.6.1.4.1.19746.3.1.11
OBJECT IDENTIFIER    

dd565 1.3.6.1.4.1.19746.3.1.12
OBJECT IDENTIFIER    

dd530 1.3.6.1.4.1.19746.3.1.13
OBJECT IDENTIFIER    

dd510 1.3.6.1.4.1.19746.3.1.14
OBJECT IDENTIFIER    

dd120 1.3.6.1.4.1.19746.3.1.15
OBJECT IDENTIFIER    

dd590 1.3.6.1.4.1.19746.3.1.16
OBJECT IDENTIFIER    

dd590g 1.3.6.1.4.1.19746.3.1.17
OBJECT IDENTIFIER    

ddModelUnsupported 1.3.6.1.4.1.19746.3.1.9999
OBJECT IDENTIFIER    

Defined Objects

EnclosureID  
INTEGER    

Temperature  
INTEGER    

Minutes  
INTEGER    

Percentage  
INTEGER 0..100    

KBytesPerSecond  
Counter32    

OpsPerSecond  
Counter32    

ErrorCount  
Counter32    

PowerModuleIndex  
INTEGER    

PowerModuleStatus  
INTEGER ok(1), unknown(2), fail(3)    

TempSensorIndex  
INTEGER    

TempSensorDescription  
DisplayString SIZE(0..64)    

TempSensorStatus  
INTEGER absent(0), ok(1), notfound(2)    

FanIndex  
INTEGER    

FanDescription  
DisplayString SIZE(0..64)    

FanLevel  
INTEGER unknown(0), low(1), normal(2), high(3)    

FanStatus  
INTEGER notfound(0), ok(1), fail(2)    

NvramMemorySize  
INTEGER    

NvramWindowSize  
INTEGER    

NvramBytesTransferred  
INTEGER    

NvramBatteryIndex  
INTEGER    

NvramBatteryStatus  
INTEGER ok(1), disabled(2), discharged(3), unknown(4), softdisabled(5)    

DiskIndex  
INTEGER    

DiskModel  
DisplayString SIZE(0..64)    

DiskFirmwareVersion  
DisplayString SIZE(0..64)    

DiskSerialNumber  
DisplayString SIZE(0..64)    

DiskCapacity  
DisplayString SIZE(0..20)    

DiskState  
INTEGER ok(1), unknown(2), absent(3), failed(4)    

DiskSectorsPerSecond  
Counter32    

FileSystemStatus  
INTEGER enabled(1), disabled(2), running(3), unknown(4)    

FileSystemResourceIndex  
INTEGER    

FileSystemResourceName  
DisplayString SIZE(0..64)    

FileSystemSpaceUnit  
Counter32    

AlertIndex  
INTEGER    

AlertTimestamp  
DisplayString SIZE(0..64)    

AlertDescription  
DisplayString SIZE(0..255)    

SystemStatsIndex  
INTEGER    

RaidDiskState  
INTEGER inuse(1), notinuse(2), spare(3), absent(4), failed(5), unknown(6)    

RaidDiskStatus  
INTEGER ok(1), reconstructing(2), resynching(3), unknown(4)    

RaidDiskGroup  
DisplayString SIZE(0..64)    

ReplicationState  
INTEGER enabled(1), disabled(2), disabledNeedsResync(3)    

ReplicationStatus  
INTEGER connected(1), disconnected(2), migrating(3), suspended(4), neverConnected(5)    

ReplicationConnectTime  
INTEGER    

ReplicationPath  
DisplayString SIZE(0..254)    

ReplicationLag  
INTEGER    

ReplicationTraffic  
INTEGER    

ReplicationThrottle  
INTEGER    

ReplicationSyncedTime  
INTEGER    

ReplicationContext  
INTEGER    

PowerModuleEntry  
SEQUENCE    
  EnclosureID as powerEnclosureID  
  PowerModuleIndex as powerModuleIndex  
  PowerModuleStatus as powerModuleStatus  

TemperatureSensorEntry  
SEQUENCE    
  EnclosureID as tempEnclosureID  
  TempSensorIndex as tempSensorIndex  
  TempSensorDescription as tempSensorDescription  
  Temperature as tempSensorCurrentValue  
  TempSensorStatus as tempSensorStatus  

FanPropertiesEntry  
SEQUENCE    
  EnclosureID as fanEnclosureID  
  FanIndex as fanIndex  
  FanDescription as fanDescription  
  FanLevel as fanLevel  
  FanStatus as fanStatus  

NvramBatteryEntry  
SEQUENCE    
  NvramBatteryIndex as nvramBatteryIndex  
  NvramBatteryStatus as nvramBatteryStatus  
  Percentage as nvramBatteryCharge  

FileSystemSpaceEntry  
SEQUENCE    
  FileSystemResourceIndex as fileSystemResourceIndex  
  FileSystemResourceName as fileSystemResourceName  
  FileSystemSpaceUnit as fileSystemSpaceSize  
  FileSystemSpaceUnit as fileSystemSpaceUsed  
  FileSystemSpaceUnit as fileSystemSpaceAvail  
  Percentage as fileSystemPercentUsed  

CurrentAlertEntry  
SEQUENCE    
  AlertIndex as currentAlertIndex  
  AlertTimestamp as currentAlertTimestamp  
  AlertDescription as currentAlertDescription  

SystemStatsEntry  
SEQUENCE    
  SystemStatsIndex as systemStatsIndex  
  Percentage as cpu0PercentageBusy  
  Percentage as cpu1PercentageBusy  
  OpsPerSecond as nfsOpsPerSecond  
  Percentage as nfsIdlePercentage  
  Percentage as nfsProcPercentage  
  Percentage as nfsSendPercentage  
  Percentage as nfsReceivePercentage  
  OpsPerSecond as cifsOpsPerSecond  
  KBytesPerSecond as diskReadKBytesPerSecond  
  KBytesPerSecond as diskWriteKBytesPerSecond  
  Percentage as diskBusyPercentage  
  KBytesPerSecond as nvramReadKBytesPerSecond  
  KBytesPerSecond as nvramWriteKBytesPerSecond  
  KBytesPerSecond as replInKBytesPerSecond  
  KBytesPerSecond as replOutKBytesPerSecond  

DiskPropertiesEntry  
SEQUENCE    
  EnclosureID as diskPropEnclosureID  
  DiskIndex as diskPropIndex  
  DiskModel as diskModel  
  DiskFirmwareVersion as diskFirmwareVersion  
  DiskSerialNumber as diskSerialNumber  
  DiskCapacity as diskCapacity  
  DiskState as diskPropState  

DiskPerformanceEntry  
SEQUENCE    
  EnclosureID as diskPerfEnclosureID  
  DiskIndex as diskPerfIndex  
  DiskSectorsPerSecond as diskSectorsRead  
  DiskSectorsPerSecond as diskSectorsWritten  
  KBytesPerSecond as diskTotalKBytes  
  Percentage as diskBusy  
  DiskState as diskPerfState  

DiskReliabilityEntry  
SEQUENCE    
  EnclosureID as diskErrEnclosureID  
  DiskIndex as diskErrIndex  
  Temperature as diskTemperature  
  ErrorCount as diskTimeoutCount  
  ErrorCount as diskReadFailCount  
  ErrorCount as diskWriteFailCount  
  ErrorCount as diskMiscFailCount  
  ErrorCount as diskOffTrackErrCount  
  ErrorCount as diskSoftEccCount  
  ErrorCount as diskCrcErrCount  
  ErrorCount as diskProbationalCount  
  ErrorCount as diskReallocCount  
  DiskState as diskErrState  

RaidInfoEntry  
SEQUENCE    
  EnclosureID as raidDiskEnclosureID  
  DiskIndex as raidDiskIndex  
  RaidDiskState as raidDiskState  
  RaidDiskGroup as raidDiskGroup  
  RaidDiskStatus as raidDiskStatus  
  Percentage as raidDiskReconPercentage  
  Minutes as raidDiskReconMinutes  
  Percentage as raidDiskResynchPercentage  
  Minutes as raidDiskResynchMinutes  

ReplicationInfoEntry  
SEQUENCE    
  ReplicationContext as replContext  
  ReplicationState as replState  
  ReplicationStatus as replStatus  
  FileSystemStatus as replFileSysStatus  
  ReplicationConnectTime as replConnTime  
  ReplicationPath as replSource  
  ReplicationPath as replDestination  
  ReplicationLag as replLag  
  ReplicationTraffic as replPreCompBytesSent  
  ReplicationTraffic as replPostCompBytesSent  
  ReplicationTraffic as replPreCompBytesRemaining  
  ReplicationTraffic as replPostCompBytesReceived  
  ReplicationThrottle as replThrottle  
  ReplicationSyncedTime as replSyncedAsOfTime