
| RFC1155-SMI | RFC-1212 | RFC-1215 |
| SNMPv2-TC |
| enterprises | TimeTicks | OBJECT-TYPE |
| TRAP-TYPE | DisplayString |
| dell | 1.3.6.1.4.1.674 | ||
| OBJECT IDENTIFIER | |||
| server3 | 1.3.6.1.4.1.674.10892 | ||
| OBJECT IDENTIFIER | |||
| drsOutofBandGroup | 1.3.6.1.4.1.674.10892.2 | ||
| OBJECT IDENTIFIER | |||
| drsInformationGroup | 1.3.6.1.4.1.674.10892.2.1 | ||
| OBJECT IDENTIFIER | |||
| drsProductInfoGroup | 1.3.6.1.4.1.674.10892.2.1.1 | ||
| OBJECT IDENTIFIER | |||
| drsProductName | 1.3.6.1.4.1.674.10892.2.1.1.1 | ||
| 0001.0001.0001 This attribute defines the product name of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductShortName | 1.3.6.1.4.1.674.10892.2.1.1.2 | ||
| 0001.0001.0002 This attribute defines the short product name of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductDescription | 1.3.6.1.4.1.674.10892.2.1.1.3 | ||
| 0001.0001.0003 This attribute defines the product description of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductManufacturer | 1.3.6.1.4.1.674.10892.2.1.1.4 | ||
| 0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductVersion | 1.3.6.1.4.1.674.10892.2.1.1.5 | ||
| 0001.0001.0005 This attribute defines the product version of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsChassisServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.6 | ||
| 0001.0001.0007 This attribute defines the Service Tag of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductURL | 1.3.6.1.4.1.674.10892.2.1.1.7 | ||
| 0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.8 | ||
| 0001.0001.0008 This attribute defines the Asset Tag of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisLocation | 1.3.6.1.4.1.674.10892.2.1.1.9 | ||
| 0001.0001.0009 This attribute defines the location of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisName | 1.3.6.1.4.1.674.10892.2.1.1.10 | ||
| 0001.0001.0010 This attribute defines the name of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsSystemServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.11 | ||
| 0001.0001.0011 This attribute defines the service tag of a system. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductSystemAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.12 | ||
| 0001.0001.0012 This attribute defines the asset tag of a system. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductSystemSlot | 1.3.6.1.4.1.674.10892.2.1.1.13 | ||
| 0001.0001.0013 This attribute defines the slot number of a CMC. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductType | 1.3.6.1.4.1.674.10892.2.1.1.14 | ||
| 0001.0001.0014 This attribute defines type of a remote access card | |||
| OBJECT-TYPE | |||
| DellRacType | |||
| drsProductChassisDataCenter | 1.3.6.1.4.1.674.10892.2.1.1.15 | ||
| 0001.0001.0015 This attribute defines the Data Center locator of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisAisle | 1.3.6.1.4.1.674.10892.2.1.1.16 | ||
| 0001.0001.0016 This attribute defines the Aisle locator of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisRack | 1.3.6.1.4.1.674.10892.2.1.1.17 | ||
| 0001.0001.0017 This attribute defines the Rack locator of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsProductChassisRackSlot | 1.3.6.1.4.1.674.10892.2.1.1.18 | ||
| 0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsFirmwareGroup | 1.3.6.1.4.1.674.10892.2.1.2 | ||
| OBJECT IDENTIFIER | |||
| drsFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.1 | ||
| 0001.0002.0001 This attribute defines the firmware version of a chassis management controller. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsiKVMFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.2 | ||
| 0001.0002.0002 This attribute defines the firmware version of the iKVM. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsStatusGroup | 1.3.6.1.4.1.674.10892.2.2 | ||
| OBJECT IDENTIFIER | |||
| drsGlobalSystemStatus | 1.3.6.1.4.1.674.10892.2.2.1 | ||
| 0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsChassisStatusGroup | 1.3.6.1.4.1.674.10892.2.3 | ||
| OBJECT IDENTIFIER | |||
| drsStatusNowGroup | 1.3.6.1.4.1.674.10892.2.3.1 | ||
| OBJECT IDENTIFIER | |||
| drsGlobalCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.1 | ||
| 0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsIOMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.2 | ||
| 0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsKVMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.3 | ||
| 0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsRedCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.4 | ||
| 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsPowerCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.5 | ||
| 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsFanCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.6 | ||
| 0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsBladeCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.7 | ||
| 0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsTempCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.8 | ||
| 0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsCMCCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.9 | ||
| 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsChassisFrontPanelAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.10 | ||
| 0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. | |||
| OBJECT-TYPE | |||
| DellTemperatureReading | |||
| drsCMCAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.11 | ||
| 0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. | |||
| OBJECT-TYPE | |||
| DellTemperatureReading | |||
| drsCMCProcessorTemperature | 1.3.6.1.4.1.674.10892.2.3.1.12 | ||
| 0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. | |||
| OBJECT-TYPE | |||
| DellTemperatureReading | |||
| drsStatusPrevGroup | 1.3.6.1.4.1.674.10892.2.3.2 | ||
| OBJECT IDENTIFIER | |||
| drsGlobalPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.1 | ||
| 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsIOMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.2 | ||
| 0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsKVMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.3 | ||
| 0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsRedPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.4 | ||
| 0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsPowerPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.5 | ||
| 0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsFanPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.6 | ||
| 0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsBladePrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.7 | ||
| 0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsTempPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.8 | ||
| 0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsCMCPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.9 | ||
| 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsStatusChangeGroup | 1.3.6.1.4.1.674.10892.2.3.3 | ||
| OBJECT IDENTIFIER | |||
| drsGlobalChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.1 | ||
| 0003.0003.0001 This attribute defines the timestamp of the most recent global status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsIOMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.2 | ||
| 0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsKVMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.3 | ||
| 0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsRedChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.4 | ||
| 0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsPowerChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.5 | ||
| 0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsFanChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.6 | ||
| 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsBladeChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.7 | ||
| 0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsTempChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.8 | ||
| 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsCMCChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.9 | ||
| 0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsChassisPowerGroup | 1.3.6.1.4.1.674.10892.2.4 | ||
| OBJECT IDENTIFIER | |||
| drsCMCPowerTable | 1.3.6.1.4.1.674.10892.2.4.1 | ||
| 0004.0001 This object defines the CMC power table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| DrsCMCPowerTableEntry | |||
| drsCMCPowerTableEntry | 1.3.6.1.4.1.674.10892.2.4.1.1 | ||
| 0004.0001.0001 This object defines the CMC power table entry. | |||
| OBJECT-TYPE | |||
| DrsCMCPowerTableEntry | |||
| drsChassisIndex | 1.3.6.1.4.1.674.10892.2.4.1.1.1 | ||
| 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. | |||
| OBJECT-TYPE | |||
| DellCMCPowerIndexRange | |||
| drsPotentialPower | 1.3.6.1.4.1.674.10892.2.4.1.1.2 | ||
| 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsIdlePower | 1.3.6.1.4.1.674.10892.2.4.1.1.3 | ||
| 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsMaxPowerSpecification | 1.3.6.1.4.1.674.10892.2.4.1.1.4 | ||
| 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsPowerSurplus | 1.3.6.1.4.1.674.10892.2.4.1.1.5 | ||
| 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsKWhCumulative | 1.3.6.1.4.1.674.10892.2.4.1.1.6 | ||
| 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsKWhCumulativeTime | 1.3.6.1.4.1.674.10892.2.4.1.1.7 | ||
| 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. | |||
| OBJECT-TYPE | |||
| DellTimestamp | |||
| drsWattsPeakUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.8 | ||
| 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsWattsPeakTime | 1.3.6.1.4.1.674.10892.2.4.1.1.9 | ||
| 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. | |||
| OBJECT-TYPE | |||
| DellTimestamp | |||
| drsWattsMinUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.10 | ||
| 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsWattsMinTime | 1.3.6.1.4.1.674.10892.2.4.1.1.11 | ||
| 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. | |||
| OBJECT-TYPE | |||
| DellTimestamp | |||
| drsWattsResetTime | 1.3.6.1.4.1.674.10892.2.4.1.1.12 | ||
| 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. | |||
| OBJECT-TYPE | |||
| DellTimestamp | |||
| drsWattsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.13 | ||
| 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsAmpsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.14 | ||
| 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsCMCPSUTable | 1.3.6.1.4.1.674.10892.2.4.2 | ||
| 0004.0002 This object defines the CMC PSU table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| DrsCMCPSUTableEntry | |||
| drsCMCPSUTableEntry | 1.3.6.1.4.1.674.10892.2.4.2.1 | ||
| 0004.0002.0001 This object defines the CMC PSU table entry. | |||
| OBJECT-TYPE | |||
| DrsCMCPSUTableEntry | |||
| drsPSUChassisIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.1 | ||
| 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. | |||
| OBJECT-TYPE | |||
| DellCMCPowerIndexRange | |||
| drsPSUIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.2 | ||
| 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. | |||
| OBJECT-TYPE | |||
| DellCMCPSUIndexRange | |||
| drsPSULocation | 1.3.6.1.4.1.674.10892.2.4.2.1.3 | ||
| 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsPSUMonitoringCapable | 1.3.6.1.4.1.674.10892.2.4.2.1.4 | ||
| 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. | |||
| OBJECT-TYPE | |||
| DellCMCPSUCapable | |||
| drsPSUVoltsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.5 | ||
| 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsPSUAmpsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.6 | ||
| 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsPSUWattsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.7 | ||
| 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. | |||
| OBJECT-TYPE | |||
| DellPowerReading | |||
| drsChassisServerGroup | 1.3.6.1.4.1.674.10892.2.5 | ||
| OBJECT IDENTIFIER | |||
| drsCMCServerTable | 1.3.6.1.4.1.674.10892.2.5.1 | ||
| 0005.0001 This object defines the CMC server table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| DrsCMCServerTableEntry | |||
| drsCMCServerTableEntry | 1.3.6.1.4.1.674.10892.2.5.1.1 | ||
| 0005.0001.0001 This object defines the CMC server table entry. | |||
| OBJECT-TYPE | |||
| DrsCMCServerTableEntry | |||
| drsServerIndex | 1.3.6.1.4.1.674.10892.2.5.1.1.1 | ||
| 0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. | |||
| OBJECT-TYPE | |||
| DellCMCServerIndexRange | |||
| drsServerMonitoringCapable | 1.3.6.1.4.1.674.10892.2.5.1.1.2 | ||
| 0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. | |||
| OBJECT-TYPE | |||
| DellCMCServerCapable | |||
| drsServerServiceTag | 1.3.6.1.4.1.674.10892.2.5.1.1.3 | ||
| 0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsServerSlotName | 1.3.6.1.4.1.674.10892.2.5.1.1.4 | ||
| 0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsServerSlotNumber | 1.3.6.1.4.1.674.10892.2.5.1.1.5 | ||
| 0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsCMCAlertGroup | 1.3.6.1.4.1.674.10892.2.20 | ||
| OBJECT IDENTIFIER | |||
| drsChassisAlertVariables | 1.3.6.1.4.1.674.10892.2.20.10 | ||
| OBJECT IDENTIFIER | |||
| drsCASubSystem | 1.3.6.1.4.1.674.10892.2.20.10.1 | ||
| 0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsCASSCurrStatus | 1.3.6.1.4.1.674.10892.2.20.10.2 | ||
| 0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsCASSPrevStatus | 1.3.6.1.4.1.674.10892.2.20.10.3 | ||
| 0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsCASSChangeTime | 1.3.6.1.4.1.674.10892.2.20.10.4 | ||
| 0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| drsCAMessage | 1.3.6.1.4.1.674.10892.2.20.10.5 | ||
| 0020.0010.0005 This attribute defines the CSSD message of the CMC Alert | |||
| OBJECT-TYPE | |||
| DellString | |||
| drsChassisAlertGroup | 1.3.6.1.4.1.674.10892.2.20.2000 | ||
| OBJECT IDENTIFIER | |||
| alertDrscTestTrapEvent | 1.3.6.1.4.1.674.10892.2.1001 | ||
| The RAC generated a test trap event in response to a user request. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscAuthError | 1.3.6.1.4.1.674.10892.2.1002 | ||
| The RAC Authentication Failures during a time period have Exceeded a Threshold. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscLostESM | 1.3.6.1.4.1.674.10892.2.1003 | ||
| The RAC cannot communicate with the baseboard management controller (ESM). | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscFoundESM | 1.3.6.1.4.1.674.10892.2.1004 | ||
| The RAC is communicating normally with the baseboard management controller (ESM). | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscPowerOff | 1.3.6.1.4.1.674.10892.2.1005 | ||
| The RAC has detected a System power state change to powered-off. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscPowerOn | 1.3.6.1.4.1.674.10892.2.1006 | ||
| The RAC has detected a system power state change to powered-on. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscWatchdogExpired | 1.3.6.1.4.1.674.10892.2.1007 | ||
| The RAC has detected that the system watchdog has expired indicating a system hang. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscBattLow | 1.3.6.1.4.1.674.10892.2.1008 | ||
| The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscTempNormal | 1.3.6.1.4.1.674.10892.2.1009 | ||
| The RAC Temperature probe has retured to a normal value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscTempWarning | 1.3.6.1.4.1.674.10892.2.1010 | ||
| The RAC Temperature probe has detected a Warning value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscTempCritical | 1.3.6.1.4.1.674.10892.2.1011 | ||
| The RAC Temperature probe has detected a failure (or critical) value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscVoltNormal | 1.3.6.1.4.1.674.10892.2.1012 | ||
| The RAC voltage has returned to a normal value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscVoltWarning | 1.3.6.1.4.1.674.10892.2.1013 | ||
| The RAC voltage probe has detected a warning value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscVoltCritical | 1.3.6.1.4.1.674.10892.2.1014 | ||
| The RAC voltage probe has detected a failure (or critical) value. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSELWarning | 1.3.6.1.4.1.674.10892.2.1015 | ||
| The RAC has detected a new event in the System Event Log with Severity: Warning. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSELCritical | 1.3.6.1.4.1.674.10892.2.1016 | ||
| The RAC has detected a new event in the System Event Log with Severity: Critical. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSEL80percentFull | 1.3.6.1.4.1.674.10892.2.1017 | ||
| The RAC has detected that the System Event Log is 80% full. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSEL90percentFull | 1.3.6.1.4.1.674.10892.2.1018 | ||
| The RAC has detected that the System Event Log is 90% full. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSEL100percentFull | 1.3.6.1.4.1.674.10892.2.1019 | ||
| The RAC has detected that the System Event Log is 100% full. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertDrscSELNormal | 1.3.6.1.4.1.674.10892.2.1020 | ||
| The RAC has detected a new event in the System Event Log with Severity: Normal. | |||
| TRAP-TYPE | |||
| drsAlertSystem | |||
| drsAlertTableIndexOID | |||
| drsAlertMessage | |||
| drsAlertCurrentStatus | |||
| drsAlertPreviousStatus | |||
| drsAlertData | |||
| alertCMCTestTrap | 1.3.6.1.4.1.674.10892.2.2000 | ||
| The CMC has generated a test trap | |||
| TRAP-TYPE | |||
| alertCMCNormalTrap | 1.3.6.1.4.1.674.10892.2.2002 | ||
| The CMC reported a return-to-normal or informational event. | |||
| TRAP-TYPE | |||
| drsProductChassisName | |||
| drsProductChassisLocation | |||
| drsGlobalCurrStatus | |||
| drsCASubSystem | |||
| drsCASSCurrStatus | |||
| drsCASSPrevStatus | |||
| drsCASSChangeTime | |||
| drsCAMessage | |||
| alertCMCWarningTrap | 1.3.6.1.4.1.674.10892.2.2003 | ||
| The CMC reported a warning event. | |||
| TRAP-TYPE | |||
| drsProductChassisName | |||
| drsProductChassisLocation | |||
| drsGlobalCurrStatus | |||
| drsCASubSystem | |||
| drsCASSCurrStatus | |||
| drsCASSPrevStatus | |||
| drsCASSChangeTime | |||
| drsCAMessage | |||
| alertCMCCriticalTrap | 1.3.6.1.4.1.674.10892.2.2004 | ||
| The CMC reported a critical event. | |||
| TRAP-TYPE | |||
| drsProductChassisName | |||
| drsProductChassisLocation | |||
| drsGlobalCurrStatus | |||
| drsCASubSystem | |||
| drsCASSCurrStatus | |||
| drsCASSPrevStatus | |||
| drsCASSChangeTime | |||
| drsCAMessage | |||
| alertCMCNonRecoverableTrap | 1.3.6.1.4.1.674.10892.2.2005 | ||
| The CMC reported a catastrophic event. | |||
| TRAP-TYPE | |||
| drsProductChassisName | |||
| drsProductChassisLocation | |||
| drsGlobalCurrStatus | |||
| drsCASubSystem | |||
| drsCASSCurrStatus | |||
| drsCASSPrevStatus | |||
| drsCASSChangeTime | |||
| drsCAMessage | |||
| drsAlertGroup | 1.3.6.1.4.1.674.10892.2.5000 | ||
| OBJECT IDENTIFIER | |||
| drsAlertVariables | 1.3.6.1.4.1.674.10892.2.5000.10 | ||
| OBJECT IDENTIFIER | |||
| drsAlertSystem | 1.3.6.1.4.1.674.10892.2.5000.10.1 | ||
| 5000.0010.0001 Name of the system generating the alert. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| drsAlertTableIndexOID | 1.3.6.1.4.1.674.10892.2.5000.10.2 | ||
| 5000.0010.0002 0.0 | |||
| OBJECT-TYPE | |||
| OBJECT IDENTIFIER | |||
| drsAlertMessage | 1.3.6.1.4.1.674.10892.2.5000.10.3 | ||
| 5000.0010.0003 Message describing the alert. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..1024) | ||
| drsAlertCurrentStatus | 1.3.6.1.4.1.674.10892.2.5000.10.4 | ||
| 5000.0010.0004 Current status of object causing the alert. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsAlertPreviousStatus | 1.3.6.1.4.1.674.10892.2.5000.10.5 | ||
| 5000.0010.0005 Previous status of object causing the alert. | |||
| OBJECT-TYPE | |||
| DellStatus | |||
| drsAlertData | 1.3.6.1.4.1.674.10892.2.5000.10.6 | ||
| 5000.0010.0006 Alert data. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..1024) | ||
| DellString | |||
| DisplayString | SIZE(0..1023) | ||
| DellRacType | |||
| INTEGER | other(1), unknown(2), dracIII(3), era(4), drac4(5), drac5(6), drac5MC(7), cmc(8), idrac(9) | ||
| DellStatus | |||
| INTEGER | other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6) | ||
| DellPowerReading | |||
| DisplayString | SIZE(0..32) | ||
| DellCMCPowerIndexRange | |||
| INTEGER | 1..1 | ||
| DellCMCPSUIndexRange | |||
| INTEGER | 1..6 | ||
| DellCMCPSUCapable | |||
| INTEGER | absent(1), none(2), basic(3) | ||
| DellTemperatureReading | |||
| INTEGER | |||
| DellTimestamp | |||
| DisplayString | SIZE(26) | ||
| DellCMCServerIndexRange | |||
| INTEGER | 1..32 | ||
| DellCMCServerCapable | |||
| INTEGER | absent(1), none(2), basic(3), off(4) | ||
| DrsCMCPowerTableEntry | |||
| SEQUENCE | |||
| DellCMCPowerIndexRange as drsChassisIndex | |||
| DellPowerReading as drsPotentialPower | |||
| DellPowerReading as drsIdlePower | |||
| DellPowerReading as drsMaxPowerSpecification | |||
| DellPowerReading as drsPowerSurplus | |||
| DellPowerReading as drsKWhCumulative | |||
| DellTimestamp as drsKWhCumulativeTime | |||
| DellPowerReading as drsWattsPeakUsage | |||
| DellTimestamp as drsWattsPeakTime | |||
| DellPowerReading as drsWattsMinUsage | |||
| DellTimestamp as drsWattsMinTime | |||
| DellTimestamp as drsWattsResetTime | |||
| DellPowerReading as drsWattsReading | |||
| DellPowerReading as drsAmpsReading | |||
| DrsCMCPSUTableEntry | |||
| SEQUENCE | |||
| DellCMCPowerIndexRange as drsPSUChassisIndex | |||
| DellCMCPSUIndexRange as drsPSUIndex | |||
| DellString as drsPSULocation | |||
| DellCMCPSUCapable as drsPSUMonitoringCapable | |||
| DellPowerReading as drsPSUVoltsReading | |||
| DellPowerReading as drsPSUAmpsReading | |||
| DellPowerReading as drsPSUWattsReading | |||
| DrsCMCServerTableEntry | |||
| SEQUENCE | |||
| DellCMCServerIndexRange as drsServerIndex | |||
| DellCMCServerCapable as drsServerMonitoringCapable | |||
| DellString as drsServerServiceTag | |||
| DellString as drsServerSlotName | |||
| DellString as drsServerSlotNumber | |||