DV2-MIB

File: DV2-MIB.mib (545996 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1215
RFC-1212

Imported symbols

enterprises IpAddress Counter
Gauge DisplayString PhysAddress
TRAP-TYPE OBJECT-TYPE

Defined Objects

netcomm 1.3.6.1.4.1.251
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.251.1
OBJECT IDENTIFIER    

dv2 1.3.6.1.4.1.251.1.1
OBJECT IDENTIFIER    

dv2System 1.3.6.1.4.1.251.1.1.1
OBJECT IDENTIFIER    

dv2Message 1.3.6.1.4.1.251.1.1.1
This is used to send an arbitary text string to the NMS.
TRAP-TYPE    
  sysLastTrapMessage  

sysMemEnd 1.3.6.1.4.1.251.1.1.1.1
The current end of run-time allocated memory.
OBJECT-TYPE    
  Hex  

sysInitialMemB 1.3.6.1.4.1.251.1.1.1.4
initial number of memory items.
OBJECT-TYPE    
  INTEGER  

sysCurrentMemB 1.3.6.1.4.1.251.1.1.1.5
Current number of memory items.
OBJECT-TYPE    
  INTEGER  

sysInitialSema 1.3.6.1.4.1.251.1.1.1.6
Initial number of semaphores.
OBJECT-TYPE    
  INTEGER  

sysCurrentSema 1.3.6.1.4.1.251.1.1.1.7
Current number of semaphores.
OBJECT-TYPE    
  INTEGER  

sysInitialQItems 1.3.6.1.4.1.251.1.1.1.8
Initial number of queue items.
OBJECT-TYPE    
  INTEGER  

sysCurrentQItems 1.3.6.1.4.1.251.1.1.1.9
Current number of queue items.
OBJECT-TYPE    
  INTEGER  

sysInitialQs 1.3.6.1.4.1.251.1.1.1.10
Initial number of queues.
OBJECT-TYPE    
  INTEGER  

sysCurrentQs 1.3.6.1.4.1.251.1.1.1.11
Current number of queues.
OBJECT-TYPE    
  INTEGER  

sysInitialPorts 1.3.6.1.4.1.251.1.1.1.12
Initial number of ports.
OBJECT-TYPE    
  INTEGER  

sysCurrentPorts 1.3.6.1.4.1.251.1.1.1.13
Current number of ports.
OBJECT-TYPE    
  INTEGER  

sysDefaultCellMode 1.3.6.1.4.1.251.1.1.1.14
This flag indicates whether the cell interface is operating in default mode. If yes(2) then this indicates that the daughter card processor is not running its correct code.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sysLinkTable 1.3.6.1.4.1.251.1.1.1.15
This table contains information about each link on this slot controller.
OBJECT-TYPE    
  SEQUENCE OF  
    SysLinkEntry

sysLinkEntry 1.3.6.1.4.1.251.1.1.1.15.1
OBJECT-TYPE    
  SysLinkEntry  

sysLkLinkNo 1.3.6.1.4.1.251.1.1.1.15.1.1
The link number on the slot
OBJECT-TYPE    
  INTEGER 0..3  


sysLkState 1.3.6.1.4.1.251.1.1.1.15.1.3
Status of the link
OBJECT-TYPE    
  INTEGER up(1), down(2), stop(3)  

sysLkTxCells 1.3.6.1.4.1.251.1.1.1.15.1.4
Number of cells sent from link
OBJECT-TYPE    
  Counter  

sysLkRxCells 1.3.6.1.4.1.251.1.1.1.15.1.5
Number of cells received to link
OBJECT-TYPE    
  Counter  

sysLkTxRate 1.3.6.1.4.1.251.1.1.1.15.1.6
Cells per second sent from link
OBJECT-TYPE    
  Gauge  

sysLkRxRate 1.3.6.1.4.1.251.1.1.1.15.1.7
Cells per second received to link
OBJECT-TYPE    
  Gauge  

sysLkTxMaxRate 1.3.6.1.4.1.251.1.1.1.15.1.8
Maximum cells per second transmitted from link
OBJECT-TYPE    
  Gauge  

sysLkRxMaxRate 1.3.6.1.4.1.251.1.1.1.15.1.9
Maximum cells per second received to link
OBJECT-TYPE    
  Gauge  

sysLkResetStats 1.3.6.1.4.1.251.1.1.1.15.1.10
Set to yes(2) to reset the link statistics
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sysLkClockSrc 1.3.6.1.4.1.251.1.1.1.15.1.11
This specifies where the link obtains its clock
OBJECT-TYPE    
  INTEGER normal(1), low-quality(2), high-quality(3), loop-timed(4), local(5)  

sysLkResetResrc 1.3.6.1.4.1.251.1.1.1.15.1.12
Set to yes(2) to reset the link resources
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sysLKEgCLPThreshold 1.3.6.1.4.1.251.1.1.1.15.1.13
Transmit CLP1 threshold
OBJECT-TYPE    
  INTEGER 0..63  

sysLKIgCLPThreshold 1.3.6.1.4.1.251.1.1.1.15.1.14
Receive CLP1 threshold
OBJECT-TYPE    
  INTEGER 0..63  

sysLKEgEFCIThreshold 1.3.6.1.4.1.251.1.1.1.15.1.15
Transmit EFCI threshold
OBJECT-TYPE    
  INTEGER 0..63  

sysLKIgEFCIThreshold 1.3.6.1.4.1.251.1.1.1.15.1.16
Receive EFCI threshold
OBJECT-TYPE    
  INTEGER 0..63  

sysLKEgLogBuffer 1.3.6.1.4.1.251.1.1.1.15.1.17
Transmit logic buffer size
OBJECT-TYPE    
  INTEGER 0..63  

sysLKIgLogBuffer 1.3.6.1.4.1.251.1.1.1.15.1.18
Receive logic buffer size
OBJECT-TYPE    
  INTEGER 0..63  

sysLKEgFIFODepth 1.3.6.1.4.1.251.1.1.1.15.1.19
Transmit FIFO Depth
OBJECT-TYPE    
  INTEGER  

sysLKIgFIFODepth 1.3.6.1.4.1.251.1.1.1.15.1.20
Receive FIFO Depth
OBJECT-TYPE    
  INTEGER  

sysLKEgMemBlockId 1.3.6.1.4.1.251.1.1.1.15.1.21
Transmit Memory Block ID
OBJECT-TYPE    
  INTEGER mem-4k(4), mem-16k(16), mem-64k(63)  

sysLKIgMemBlockId 1.3.6.1.4.1.251.1.1.1.15.1.22
Receive Memory Block ID
OBJECT-TYPE    
  INTEGER mem-4k(4), mem-16k(16), mem-64k(63)  

sysDbTable 1.3.6.1.4.1.251.1.1.1.16
This table contains information about the internal buffer pool on the slot controller.
OBJECT-TYPE    
  SEQUENCE OF  
    SysDbEntry

sysDbEntry 1.3.6.1.4.1.251.1.1.1.16.1
OBJECT-TYPE    
  SysDbEntry  

sysDbIndex 1.3.6.1.4.1.251.1.1.1.16.1.1
Buffer class number
OBJECT-TYPE    
  INTEGER 0..10  

sysDbSize 1.3.6.1.4.1.251.1.1.1.16.1.2
Five classes of buffers are used:- 16, 128, 368 and 1600 bytes plus 48 bytes for cells.
OBJECT-TYPE    
  INTEGER buff16(16), buff128(128), buff368(368), buff1600(1600), cells(48), signal-quota(1), ip-quota(2)  

sysDbInitial 1.3.6.1.4.1.251.1.1.1.16.1.3
This is the initial number of buffers available.
OBJECT-TYPE    
  INTEGER  

sysDbCurrent 1.3.6.1.4.1.251.1.1.1.16.1.4
This is the current number of buffers available.
OBJECT-TYPE    
  INTEGER  

sysAuthenticateTable 1.3.6.1.4.1.251.1.1.1.17
Table containing all the authentication tuples for this agent.
OBJECT-TYPE    
  SEQUENCE OF  
    SysAuthenticateEntry

sysAuthenticateEntry 1.3.6.1.4.1.251.1.1.1.17.1
An authentication tuple. A PDU from the ipaddress specified that contains the community, will have access to this MIB.
OBJECT-TYPE    
  SysAuthenticateEntry  

sysAuIndex 1.3.6.1.4.1.251.1.1.1.17.1.1
Index, identifying each entry in the authentication table.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sysAuIpaddress 1.3.6.1.4.1.251.1.1.1.17.1.2
The network address of the manager that has authentication access to this agent.
OBJECT-TYPE    
  IpAddress  

sysAuCommunity 1.3.6.1.4.1.251.1.1.1.17.1.3
The SNMP community for which the ipaddress is authenticated.
OBJECT-TYPE    
  DisplayString  

sysAuAccess 1.3.6.1.4.1.251.1.1.1.17.1.4
Access permission for this ipaddress/community tuple. Write access is required for performing SNMP sets.
OBJECT-TYPE    
  INTEGER readOnly(1), readWrite(3)  

sysAuSendTraps 1.3.6.1.4.1.251.1.1.1.17.1.5
Set to send-none(2) to prevent traps being sent to this host.
OBJECT-TYPE    
  INTEGER send-all(1), send-none(2)  

sysAuValidity 1.3.6.1.4.1.251.1.1.1.17.1.6
Set to invalid(2) to delete this row.
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

sysLastTrapMessage 1.3.6.1.4.1.251.1.1.1.18
This is used to contain the last trap string sent.
OBJECT-TYPE    
  DisplayString SIZE(0..70)  

sysConfigChanged 1.3.6.1.4.1.251.1.1.1.19
This indicates that a new file is available. This should not be set by the user.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sysConfigFile 1.3.6.1.4.1.251.1.1.1.20
Set to read(2) to re-read the file. Set to write(3) to write the existing configuration to .
OBJECT-TYPE    
  INTEGER no-action(1), read(2), write(3)  

sysCompileTime 1.3.6.1.4.1.251.1.1.1.21
Date and time of link in the form dd Mon yyyy hh:mm:ss. For example:- 15 Aug 1994 10:12:21
OBJECT-TYPE    
  DisplayString  

slotNumber 1.3.6.1.4.1.251.1.1.1.22
Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

sysLastResetTimeM2 1.3.6.1.4.1.251.1.1.1.23
Date and time board was last reset.
OBJECT-TYPE    
  DateAndTime  

sysCurrentTimeM2 1.3.6.1.4.1.251.1.1.1.24
Current date and time in the form dd Mon yyyy hh:mm:ss. For example:- 15 Aug 1994 10:12:21
OBJECT-TYPE    
  DateAndTime  

limTypeStatus 1.3.6.1.4.1.251.1.1.1.25
Describes whether the lim and the DOC card are compatible.
OBJECT-TYPE    
  INTEGER unknown(1), compatible(2), not-compatible(3)  

dv2Slot0 1.3.6.1.4.1.251.1.1.2
OBJECT IDENTIFIER    

slotChanged 1.3.6.1.4.1.251.1.1.2
This is sent when a slot changes state.
TRAP-TYPE    
  slot0PhySlotNo  
  slot0PhyState  

slot0IntIp 1.3.6.1.4.1.251.1.1.2.1
IP address of SLOT 0 for ATM interface.
OBJECT-TYPE    
  IpAddress  

slot0XpInUse 1.3.6.1.4.1.251.1.1.2.2
The current Switch Fabric in Service
OBJECT-TYPE    
  INTEGER unknown(3), main-in-service(1), standby-in-service(2)  

slot0XpToUse 1.3.6.1.4.1.251.1.1.2.3
This indicates the switch fabric card you want the switch to use.
OBJECT-TYPE    
  INTEGER auto(3), main(1), standby(2), not-applicable(4)  

slot0StandbyXp 1.3.6.1.4.1.251.1.1.2.4
Set to yes(1) to enable standby switch fabric.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

slot0PsuTable 1.3.6.1.4.1.251.1.1.2.5
OBJECT-TYPE    
  SEQUENCE OF  
    Slot0PsuEntry

slot0PsuEntry 1.3.6.1.4.1.251.1.1.2.5.1
OBJECT-TYPE    
  Slot0PsuEntry  

slot0PsuIndex 1.3.6.1.4.1.251.1.1.2.5.1.1
Power-supply number.
OBJECT-TYPE    
  INTEGER 0..3  

slot0PsuFault 1.3.6.1.4.1.251.1.1.2.5.1.2
If fault(2) then this indicates a fault condition in the power-supply.
OBJECT-TYPE    
  INTEGER absent(3), ok(1), fault(2)  

slot0PsuTestFault 1.3.6.1.4.1.251.1.1.2.5.1.3
If set to yes(1) the control button on the PSU module has been set to test fault mode.
OBJECT-TYPE    
  INTEGER no(1), yes(2), not-applicable(3)  

slot0PsuVoltage 1.3.6.1.4.1.251.1.1.2.5.1.4
This is a the voltage generated by the power-supply in millivolts.
OBJECT-TYPE    
  INTEGER  

slot0PsuTemp 1.3.6.1.4.1.251.1.1.2.5.1.5
This is the temperature of the power-supply module in degrees celsius.
OBJECT-TYPE    
  INTEGER  

slot0PsuFanASpeed 1.3.6.1.4.1.251.1.1.2.5.1.6
This is the rotation speed of FAN A in RPM.
OBJECT-TYPE    
  INTEGER  

slot0PsuFanBSpeed 1.3.6.1.4.1.251.1.1.2.5.1.7
This is the rotation speed of FAN B in RPM.
OBJECT-TYPE    
  INTEGER  

slot0PsuFanCSpeed 1.3.6.1.4.1.251.1.1.2.5.1.8
This is the rotation speed of FAN C in RPM.
OBJECT-TYPE    
  INTEGER  

slot0PsuReset 1.3.6.1.4.1.251.1.1.2.5.1.9
If set to yes(2) then the power-supply module is returned to its initial state.
OBJECT-TYPE    
  INTEGER no(1), yes(2), not-applicable(3)  

slot0PsuType 1.3.6.1.4.1.251.1.1.2.5.1.10
Shows the type of PSU fitted into switch.
OBJECT-TYPE    
  INTEGER v1-ATM-SWITCH(1), v2-ATM-SWITCH(2), v3-ATM-SWITCH(3), v4-ATM-SWITCH(4), v5-ATM-SWITCH(5)  

slot0PsuFanFail 1.3.6.1.4.1.251.1.1.2.5.1.11
Set to yes(2) if the fan fails.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

slot0PsuTooHot 1.3.6.1.4.1.251.1.1.2.5.1.12
Set to yes(2) if the PSU is too hot
OBJECT-TYPE    
  INTEGER no(1), yes(2), not-applicable(3)  

slot0PsuFrontTooHot 1.3.6.1.4.1.251.1.1.2.5.1.13
Set to yes(2) if the Front is too hot
OBJECT-TYPE    
  INTEGER no(1), yes(2), not-applicable(3)  

slot0PhyTable 1.3.6.1.4.1.251.1.1.2.6
This table summarises the hardware installed in the switch.
OBJECT-TYPE    
  SEQUENCE OF  
    Slot0PhyEntry

slot0PhyEntry 1.3.6.1.4.1.251.1.1.2.6.1
OBJECT-TYPE    
  Slot0PhyEntry  

slot0PhySlotNo 1.3.6.1.4.1.251.1.1.2.6.1.1
This is the slot number in the switch.
OBJECT-TYPE    
  INTEGER 0..15  

slot0PhyName 1.3.6.1.4.1.251.1.1.2.6.1.2
This is a mnemonic name for the slot.
OBJECT-TYPE    
  DisplayString  

slot0PhyType 1.3.6.1.4.1.251.1.1.2.6.1.3
This enumerated type defines the type of card fitted in the slot.
OBJECT-TYPE    
  INTEGER unknown(1), dxdoc(128), qedoc(129), vcdoc(130), cp(133), cl(134), cs(135), hp(136), hl(137), hs(138), ce(139), ve(140), chfrc(141), eth(142), frac(143), trdoc(144), sce(145), dv2ap(146), dv2as(147), vsm(148), ipas(149), ipap(150)  

slot0PhyDlim 1.3.6.1.4.1.251.1.1.2.6.1.4
This is the type of DLIM fitted to the slot.
OBJECT-TYPE    
  INTEGER unknown(1), dx21(2), dx27(3), d2G703(4), d8G703(5), d34G703(6), dAUI(7), dlfLIM(8), dds1(9), dds3(10), dhssi(11), dsolim(12), ds3-2c(13), e3-2c(14), e1-dual(15), e1-quad(16), ds1-dual(17), ds1-quad(18), jpeg(19), j2-dual(20), j2-quad(21), vh320(22), si-dual(23), si-quad(24), delim(25), mpg2v(26), qtlim(27)  

slot0PhySwVer 1.3.6.1.4.1.251.1.1.2.6.1.5
Version of the software running on this slot controller.
OBJECT-TYPE    
  DisplayString  

slot0PhyState 1.3.6.1.4.1.251.1.1.2.6.1.6
The state of the slot, -(1) indicates no card fitted.
OBJECT-TYPE    
  INTEGER absent(1), bootmode(2), active(3), shutdown(4), shadow(5)  

slot0PhyReset 1.3.6.1.4.1.251.1.1.2.6.1.7
Setting to yes(2) will reset the slot - use with care
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

slot0PhyReqState 1.3.6.1.4.1.251.1.1.2.6.1.8
Setting to shutdown(2) will stop the slot running. The slot should only be set to main(3) or shadow(4) if the slot is operating in hardware redundant mode with an adjacent slot.
OBJECT-TYPE    
  INTEGER normal(1), shutdown(2), main(3), shadow(4)  

slot0PhyStateChange 1.3.6.1.4.1.251.1.1.2.6.1.10
Indicates link has changed state.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

slot0PhyLinkedSlot 1.3.6.1.4.1.251.1.1.2.6.1.11
This is used in hardware redundancy mode. If set to 0 then there is no associated slot. Otherwise the value is the slot number that will be used if this slot fails.
OBJECT-TYPE    
  INTEGER 0..15  

slot0PhyLink0State 1.3.6.1.4.1.251.1.1.2.6.1.12
This contains link 0 status.
OBJECT-TYPE    
  INTEGER stop(4), up(1), down(2), off(3), reset(5)  

slot0PhyLink1State 1.3.6.1.4.1.251.1.1.2.6.1.13
This contains link 1 status.
OBJECT-TYPE    
  INTEGER stop(4), up(1), down(2), off(3), reset(5)  

slot0PhyLink2State 1.3.6.1.4.1.251.1.1.2.6.1.14
This contains link 2 status.
OBJECT-TYPE    
  INTEGER stop(4), up(1), down(2), off(3), reset(5)  

slot0PhyLink3State 1.3.6.1.4.1.251.1.1.2.6.1.15
This contains link 3 status.
OBJECT-TYPE    
  INTEGER stop(4), up(1), down(2), off(3), reset(5)  

slot0PhySlotSerNo 1.3.6.1.4.1.251.1.1.2.6.1.16
Serial number of the slot controller.
OBJECT-TYPE    
  DisplayString  

slot0PhySlotHwVerNo 1.3.6.1.4.1.251.1.1.2.6.1.17
Hardware version number and revision of the slot controller.
OBJECT-TYPE    
  DisplayString  

slot0PhyDocSerNo 1.3.6.1.4.1.251.1.1.2.6.1.18
Serial number of the DOC.
OBJECT-TYPE    
  DisplayString  

slot0PhyDocHwVerNo 1.3.6.1.4.1.251.1.1.2.6.1.19
Hardware version number and revision of the DOC.
OBJECT-TYPE    
  DisplayString  

slot0PhyMacAddress 1.3.6.1.4.1.251.1.1.2.6.1.20
MAC address of the slot.
OBJECT-TYPE    
  PhysAddress  

slot0PhyChangeTimeM2 1.3.6.1.4.1.251.1.1.2.6.1.21
Last date and time link changed state.
OBJECT-TYPE    
  DateAndTime  

slot0PhyLstChngLnkNum 1.3.6.1.4.1.251.1.1.2.6.1.22
Holds the link number of the last link status to change.
OBJECT-TYPE    
  INTEGER link-0(1), link-1(2), link-2(3), link-3(4), none(5)  

slot0PhyLstChngPrevLnkStat 1.3.6.1.4.1.251.1.1.2.6.1.23
Holds the previous link state of the last link number whose status changed.
OBJECT-TYPE    
  INTEGER up(1), down(2), off(3), stop(4), reset(5), none(6)  

slot0MaxUpSlots 1.3.6.1.4.1.251.1.1.2.7
The maximum number of slots that have been up.
OBJECT-TYPE    
  INTEGER  

slot0CurrentUpSlots 1.3.6.1.4.1.251.1.1.2.8
The number of slots currently up.
OBJECT-TYPE    
  INTEGER  

slot0IsStandbySlot0 1.3.6.1.4.1.251.1.1.2.9
Set to yes(2) if there is a redundant slot 0 available.
OBJECT-TYPE    
  INTEGER unknown(5), not-applicable(4), no(1), yes(2), not-ready(6)  

slot0TftpToStandby 1.3.6.1.4.1.251.1.1.2.10
Set to no(2) to stop files being transferred to the out of service slot0 automatically when they are changed.
OBJECT-TYPE    
  INTEGER yes(2), no(1)  

slot0MibBroadcast 1.3.6.1.4.1.251.1.1.2.11
Broadcasts particular tables to all other slots.
OBJECT-TYPE    
  INTEGER none(1), snmp-Authentication(2)  

slot0Address 1.3.6.1.4.1.251.1.1.2.14
The E.164 address of the switch.
OBJECT-TYPE    
  E164  

slot0InUse 1.3.6.1.4.1.251.1.1.2.15
The Slot 0 card Redundancy Status.
OBJECT-TYPE    
  INTEGER unknown(5), main-in-service(1), standby-in-service(2), main-out-of-service(3), standby-out-of-service(4), main-disabled(6), standby-disabled(7)  

slot0ToUse 1.3.6.1.4.1.251.1.1.2.16
This indicates the Slot 0 card you want the switch to use.
OBJECT-TYPE    
  INTEGER auto(3), main(1), standby(2), not-applicable(4), disable(5)  

slot0redmode 1.3.6.1.4.1.251.1.1.2.17
The Slot 0 card Redundancy mode.
OBJECT-TYPE    
  INTEGER unknown(4), non-redundant(1), basic-redundancy(2), enhanced-redundancy(3)  

slot0IntIPMask 1.3.6.1.4.1.251.1.1.2.18
IP Mask for Internal Subnet. To reconfigure, Save new configuration and perform then warm Start.
OBJECT-TYPE    
  IpAddress  

slot0SwitchId 1.3.6.1.4.1.251.1.1.2.19
Switch ID for this Apex node
OBJECT-TYPE    
  INTEGER 0..255  

ntms0doc 1.3.6.1.4.1.251.1.1.2.20
Signifies that the S0DOC is capable of communicating with an NTM
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

slot0LecsPrefix 1.3.6.1.4.1.251.1.1.2.21
The NSAP network prefix for LECS.
OBJECT-TYPE    
  E164  

slot0LecsESI 1.3.6.1.4.1.251.1.1.2.22
The NSAP ESI for LECS.
OBJECT-TYPE    
  E164  

dv2Trace 1.3.6.1.4.1.251.1.1.3
OBJECT IDENTIFIER    

linkChanged 1.3.6.1.4.1.251.1.1.3
This is sent when a link changes state.
TRAP-TYPE    
  slot0PhySlotNo  
  slot0PhyLink0State  
  slot0PhyLink1State  
  slot0PhyLink2State  
  slot0PhyLink3State  
  slot0PhyLstChngLnkNum  
  slot0PhyLstChngPrevLnkStat  

traceIp 1.3.6.1.4.1.251.1.1.3.1
Toggle for IP trace flag.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

traceUdp 1.3.6.1.4.1.251.1.1.3.2
Toggle for UDP trace flag.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

traceTcp 1.3.6.1.4.1.251.1.1.3.3
Toggle for TCP trace flag.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

traceSnmp 1.3.6.1.4.1.251.1.1.3.4
Toggle for SNMP trace flag.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

traceCat 1.3.6.1.4.1.251.1.1.3.5
Toggle for CAT trace flag.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dv2SlipLine 1.3.6.1.4.1.251.1.1.4
OBJECT IDENTIFIER    

psuChanged 1.3.6.1.4.1.251.1.1.4
This is sent when a power supply changes state.
TRAP-TYPE    
  slot0PsuIndex  
  slot0PsuFault  

slipIp 1.3.6.1.4.1.251.1.1.4.1
IP address of SLIP line.
OBJECT-TYPE    
  IpAddress  

slipMask 1.3.6.1.4.1.251.1.1.4.2
Mask for SLIP line.
OBJECT-TYPE    
  IpAddress  

slipRemoteIp 1.3.6.1.4.1.251.1.1.4.3
IP address of remote end of SLIP line.
OBJECT-TYPE    
  IpAddress  

slipSpeed 1.3.6.1.4.1.251.1.1.4.4
Baud rate of SLIP serial line.
OBJECT-TYPE    
  INTEGER baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5), baud57600(6), baud115200(7)  

dv2StaticRoute 1.3.6.1.4.1.251.1.1.5
OBJECT IDENTIFIER    

configChanged 1.3.6.1.4.1.251.1.1.5
This is sent when has changed.
TRAP-TYPE    
  sysConfigChanged  
  slotNumber  

dv2Clocks 1.3.6.1.4.1.251.1.1.6
OBJECT IDENTIFIER    

clksTxTimingRef 1.3.6.1.4.1.251.1.1.6.1
Transmit Timing Reference
OBJECT-TYPE    
  INTEGER system-timing-reference(1), local-link0(2), local-link1(3), local-oscillator(4)  

clksSysRefSlotNum 1.3.6.1.4.1.251.1.1.6.2
System Timing Reference Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

clksSysRefLinkNum 1.3.6.1.4.1.251.1.1.6.3
System Timing Reference Link Number
OBJECT-TYPE    
  INTEGER link0(1), link1(2), none(3)  

clksSysRefError 1.3.6.1.4.1.251.1.1.6.4
System Timing Error
OBJECT-TYPE    
  INTEGER slot0(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), none(17)  

dv2VcDoc 1.3.6.1.4.1.251.1.1.8
OBJECT IDENTIFIER    

vcDocTable 1.3.6.1.4.1.251.1.1.8.1
OBJECT-TYPE    
  SEQUENCE OF  
    VcDocEntry

vcDocEntry 1.3.6.1.4.1.251.1.1.8.1.1
OBJECT-TYPE    
  VcDocEntry  

vcDocLinkNo 1.3.6.1.4.1.251.1.1.8.1.1.1
This is the target link number for the PVC.
OBJECT-TYPE    
  INTEGER 0..127  

vcDocEnable 1.3.6.1.4.1.251.1.1.8.1.1.2
Setting to yes(1) enables the VCDOC channel.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vcDocVpi 1.3.6.1.4.1.251.1.1.8.1.1.3
VPI of the VC being used for cell transfers.
OBJECT-TYPE    
  VirtualPathIdentifier  

vcDocVci 1.3.6.1.4.1.251.1.1.8.1.1.4
VCI of the VC being used for cell transfers.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

vcDocLinkSpeed 1.3.6.1.4.1.251.1.1.8.1.1.5
This sets the speed at which the link is to run.
OBJECT-TYPE    
  INTEGER s32kbps(64), s64kbps(128), s128kbps(192), s256kbps(224), s512kbps(240), s1024kbps(248), s2048kbps(252)  

vcDocCLines 1.3.6.1.4.1.251.1.1.8.1.1.6
This sets how control lines should be processed. If Ignore(2) is set then the port is always online.
OBJECT-TYPE    
  INTEGER process(1), ignore(2)  

vcDocFifoSize 1.3.6.1.4.1.251.1.1.8.1.1.7
This is the size of the software emulated FIFO.
OBJECT-TYPE    
  INTEGER 10..100  

vcDocLowWater 1.3.6.1.4.1.251.1.1.8.1.1.8
This is the point at which the transmit clock is switched to low frequency. This must be between 0 and FIFO Size/2
OBJECT-TYPE    
  INTEGER 0..50  

vcDocHighWater 1.3.6.1.4.1.251.1.1.8.1.1.9
This is the point at which the transmit clock is switched to high frequency. This must be between FIFO size and FIFO Size/2
OBJECT-TYPE    
  INTEGER 5..100  

vcDocTestMode 1.3.6.1.4.1.251.1.1.8.1.1.10
This is the type of self-test to perform with the VC DOC.
OBJECT-TYPE    
  INTEGER normal(1), local-loop(2), cable-loop(3), remote-loop(4), pattern-send(5)  

vcDocTestVal 1.3.6.1.4.1.251.1.1.8.1.1.11
This is the test value to use when doing the pattern-send test.
OBJECT-TYPE    
  Hex  

vcDocPriority 1.3.6.1.4.1.251.1.1.8.1.1.12
This indicates that cells will be sent with the priority bit set.
OBJECT-TYPE    
  INTEGER 0..1  

vcDocSuba 1.3.6.1.4.1.251.1.1.8.1.1.13
This is the target link number for the VC.
OBJECT-TYPE    
  INTEGER 0..3  

vcDocSaddr 1.3.6.1.4.1.251.1.1.8.1.1.14
This is the target slot number for the VC.
OBJECT-TYPE    
  INTEGER 0..15  

vcDocClockFix 1.3.6.1.4.1.251.1.1.8.1.1.15
If yes(2) then the clock will not be varied to maintain the size of the send FIFO.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vcStatTable 1.3.6.1.4.1.251.1.1.8.2
This is a two row table that contains status information about the VCDOC.
OBJECT-TYPE    
  SEQUENCE OF  
    VcStatEntry

vcStatEntry 1.3.6.1.4.1.251.1.1.8.2.1
OBJECT-TYPE    
  VcStatEntry  

vcStatPortNo 1.3.6.1.4.1.251.1.1.8.2.1.1
This is the originating port number for the PVC
OBJECT-TYPE    
  INTEGER 0..1  

vcStatRxState 1.3.6.1.4.1.251.1.1.8.2.1.2
This indicates whether control lines are high at the other end of the link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

vcStatTxState 1.3.6.1.4.1.251.1.1.8.2.1.3
This indicates whether the local control lines are high.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

vcStatFifoCount 1.3.6.1.4.1.251.1.1.8.2.1.4
This indicates the number of cells waiting in the FIFO.
OBJECT-TYPE    
  INTEGER  

vcStatOFlow 1.3.6.1.4.1.251.1.1.8.2.1.5
Number of Overflows.
OBJECT-TYPE    
  INTEGER  

vcStatUFlow 1.3.6.1.4.1.251.1.1.8.2.1.6
Number of Underflows.
OBJECT-TYPE    
  INTEGER  

vcStatReSync 1.3.6.1.4.1.251.1.1.8.2.1.7
This is the number of times a sequence number resync has been required.
OBJECT-TYPE    
  INTEGER  

vcStatInvented 1.3.6.1.4.1.251.1.1.8.2.1.8
Number of invented cells.
OBJECT-TYPE    
  INTEGER  

vcStatRxCells 1.3.6.1.4.1.251.1.1.8.2.1.9
Received cells count.
OBJECT-TYPE    
  Counter  

vcStatTxCells 1.3.6.1.4.1.251.1.1.8.2.1.10
Transmitted cells count.
OBJECT-TYPE    
  Counter  

vcStatRxSeqNo 1.3.6.1.4.1.251.1.1.8.2.1.11
Receive current sequence number.
OBJECT-TYPE    
  INTEGER  

vcStatTxSeqNo 1.3.6.1.4.1.251.1.1.8.2.1.12
Transmit current sequence number.
OBJECT-TYPE    
  INTEGER  

vcStatLastError 1.3.6.1.4.1.251.1.1.8.2.1.13
Last error type.
OBJECT-TYPE    
  INTEGER  

vcStatLastCompare 1.3.6.1.4.1.251.1.1.8.2.1.14
Last compare value.
OBJECT-TYPE    
  INTEGER  

vcStatTestErrors 1.3.6.1.4.1.251.1.1.8.2.1.15
Number of test errors detected.
OBJECT-TYPE    
  INTEGER  

dv2FrRelay 1.3.6.1.4.1.251.1.1.9
OBJECT IDENTIFIER    

fRelayStatTable 1.3.6.1.4.1.251.1.1.9.1
This contains the overall status information for the frame relay links.
OBJECT-TYPE    
  SEQUENCE OF  
    FRelayStatEntry

fRelayStatEntry 1.3.6.1.4.1.251.1.1.9.1.1
OBJECT-TYPE    
  FRelayStatEntry  

fRelStatLinkNo 1.3.6.1.4.1.251.1.1.9.1.1.1
Local send sequence.
OBJECT-TYPE    
  INTEGER 0..1  

fRelStatLocSeq 1.3.6.1.4.1.251.1.1.9.1.1.2
Local send sequence.
OBJECT-TYPE    
  INTEGER  

fRelStatLocAck 1.3.6.1.4.1.251.1.1.9.1.1.3
Local ack sequence.
OBJECT-TYPE    
  INTEGER  

fRelStatLocState 1.3.6.1.4.1.251.1.1.9.1.1.4
Local state of link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

fRelStatLocStartT 1.3.6.1.4.1.251.1.1.9.1.1.5
Local start time for poll.
OBJECT-TYPE    
  INTEGER  

fRelStatLocErrThr 1.3.6.1.4.1.251.1.1.9.1.1.6
Local error threshold Counter.
OBJECT-TYPE    
  Counter  

fRelStatLocMec 1.3.6.1.4.1.251.1.1.9.1.1.7
Local monitored events Counter.
OBJECT-TYPE    
  Counter  

fRelStatLocPoll 1.3.6.1.4.1.251.1.1.9.1.1.8
Local poll Counter for DTE.
OBJECT-TYPE    
  Counter  

fRelStatRemSeq 1.3.6.1.4.1.251.1.1.9.1.1.9
Remote send sequence.
OBJECT-TYPE    
  INTEGER  

fRelStatRemAck 1.3.6.1.4.1.251.1.1.9.1.1.10
Remote ack sequence.
OBJECT-TYPE    
  INTEGER  

fRelStatRemState 1.3.6.1.4.1.251.1.1.9.1.1.11
Remote state of link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

fRelStatRemStartT 1.3.6.1.4.1.251.1.1.9.1.1.12
Remote start time for poll.
OBJECT-TYPE    
  INTEGER  

fRelStatRemErrThr 1.3.6.1.4.1.251.1.1.9.1.1.13
Remote error threshold Counter.
OBJECT-TYPE    
  Counter  

fRelStatRemMec 1.3.6.1.4.1.251.1.1.9.1.1.14
Remote monitored events Counter.
OBJECT-TYPE    
  Counter  

fRelStatRemPoll 1.3.6.1.4.1.251.1.1.9.1.1.15
Remote poll Counter for DTE.
OBJECT-TYPE    
  Counter  

fRelayConfTable 1.3.6.1.4.1.251.1.1.9.2
This table contains the overall configuration for the frame relay links.
OBJECT-TYPE    
  SEQUENCE OF  
    FRelayConfEntry

fRelayConfEntry 1.3.6.1.4.1.251.1.1.9.2.1
OBJECT-TYPE    
  FRelayConfEntry  

fRelConfLinkNo 1.3.6.1.4.1.251.1.1.9.2.1.1
Number of the link to configure.
OBJECT-TYPE    
  INTEGER 0..1  

fRelConfLinkEnab 1.3.6.1.4.1.251.1.1.9.2.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

fRelConfLinkMode 1.3.6.1.4.1.251.1.1.9.2.1.3
frame mode.
OBJECT-TYPE    
  INTEGER ansi(1), lmi(2), transport(3), dxi(4)  

fRelConfLinkSpeed 1.3.6.1.4.1.251.1.1.9.2.1.4
Local speed of link.
OBJECT-TYPE    
  INTEGER s48kbps(48), s56kbps(77), s64kbps(100), s72kbps(117), s128kbps(177), s153k6bps(191), s256kbps(217), s307k2bps(223), s614k4bps(240), s819k2bps(244), s1Mbps(246), s2Mbps(251), s3Mbps(253), s5Mbps(254), s10Mbps(255)  

fRelConfLinkCline 1.3.6.1.4.1.251.1.1.9.2.1.5
Set to no(2) to disable control line processing.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

fRelConfLinkType 1.3.6.1.4.1.251.1.1.9.2.1.6
Type of link.
OBJECT-TYPE    
  INTEGER user(1), network(2), nni(3)  

fRelConfN391 1.3.6.1.4.1.251.1.1.9.2.1.7
Poll count.
OBJECT-TYPE    
  INTEGER 1..255  

fRelConfN392 1.3.6.1.4.1.251.1.1.9.2.1.8
Threshold.
OBJECT-TYPE    
  INTEGER 1..10  

fRelConfN393 1.3.6.1.4.1.251.1.1.9.2.1.9
Monitored events.
OBJECT-TYPE    
  INTEGER 1..10  

fRelConfT391 1.3.6.1.4.1.251.1.1.9.2.1.10
Poll period.
OBJECT-TYPE    
  INTEGER 5..30  

fRelConfT392 1.3.6.1.4.1.251.1.1.9.2.1.11
Poll timeout.
OBJECT-TYPE    
  INTEGER 5..30  

fraPStatTable 1.3.6.1.4.1.251.1.1.9.3
This shows the status of the frame relay PVCs for link 0.
OBJECT-TYPE    
  SEQUENCE OF  
    FraPStatEntry

fraPStatEntry 1.3.6.1.4.1.251.1.1.9.3.1
OBJECT-TYPE    
  FraPStatEntry  

fraPStatDlci 1.3.6.1.4.1.251.1.1.9.3.1.1
This is the DLCI for the PVC.
OBJECT-TYPE    
  INTEGER 16..511  

fraPStatRxBCnt 1.3.6.1.4.1.251.1.1.9.3.1.2
The number of bytes received.
OBJECT-TYPE    
  Counter  

fraPStatTxBCnt 1.3.6.1.4.1.251.1.1.9.3.1.3
The number of bytes transmitted.
OBJECT-TYPE    
  Counter  

fraPStatRxFCnt 1.3.6.1.4.1.251.1.1.9.3.1.4
The number of frames received.
OBJECT-TYPE    
  Counter  

fraPStatTxFCnt 1.3.6.1.4.1.251.1.1.9.3.1.5
The number of frames transmitted.
OBJECT-TYPE    
  Counter  

fraPStatRxBRate 1.3.6.1.4.1.251.1.1.9.3.1.6
The rate of bytes being received.
OBJECT-TYPE    
  Gauge  

fraPStatTxBRate 1.3.6.1.4.1.251.1.1.9.3.1.7
The rate of bytes being transmitted.
OBJECT-TYPE    
  Gauge  

fraPStatRxFRate 1.3.6.1.4.1.251.1.1.9.3.1.8
The rate of frames being received.
OBJECT-TYPE    
  Gauge  

fraPStatTxFRate 1.3.6.1.4.1.251.1.1.9.3.1.9
The rate of frames being transmitted.
OBJECT-TYPE    
  Gauge  

fraPStatDERxF 1.3.6.1.4.1.251.1.1.9.3.1.10
The count of discarded eligible received frames.
OBJECT-TYPE    
  Counter  

fraPStatDisRxF 1.3.6.1.4.1.251.1.1.9.3.1.11
The count of discarded received frames.
OBJECT-TYPE    
  Counter  

fraPStatPvcStat 1.3.6.1.4.1.251.1.1.9.3.1.12
The state of the PVC.
OBJECT-TYPE    
  Hex  

fraPStatLinkState 1.3.6.1.4.1.251.1.1.9.3.1.13
The state of the link.
OBJECT-TYPE    
  Hex  

fraPStatLocSeq 1.3.6.1.4.1.251.1.1.9.3.1.14
The local send sequence.
OBJECT-TYPE    
  INTEGER  

fraPStatLocAck 1.3.6.1.4.1.251.1.1.9.3.1.15
The local acknowledge number.
OBJECT-TYPE    
  INTEGER  

fraPStatLocStat 1.3.6.1.4.1.251.1.1.9.3.1.16
The local state of the link.
OBJECT-TYPE    
  INTEGER  

fraPStatLocStartT 1.3.6.1.4.1.251.1.1.9.3.1.17
The local start time for poll.
OBJECT-TYPE    
  INTEGER  

fraPStatLocErrThr 1.3.6.1.4.1.251.1.1.9.3.1.18
The local error threshold Counter.
OBJECT-TYPE    
  Counter  

fraPStatLocMec 1.3.6.1.4.1.251.1.1.9.3.1.19
The local monitored event Counter.
OBJECT-TYPE    
  Counter  

fraPStatLocPoll 1.3.6.1.4.1.251.1.1.9.3.1.20
The local poll Counter for DTE.
OBJECT-TYPE    
  Counter  

fraPStatRemSeq 1.3.6.1.4.1.251.1.1.9.3.1.21
The remote send sequence.
OBJECT-TYPE    
  INTEGER  

fraPStatRemAck 1.3.6.1.4.1.251.1.1.9.3.1.22
The remote acknowledge number.
OBJECT-TYPE    
  INTEGER  

fraPStatRemStat 1.3.6.1.4.1.251.1.1.9.3.1.23
The remote state of the link.
OBJECT-TYPE    
  INTEGER  

fraPStatRemStartT 1.3.6.1.4.1.251.1.1.9.3.1.24
The remote start time for poll.
OBJECT-TYPE    
  INTEGER  

fraPStatRemErrThr 1.3.6.1.4.1.251.1.1.9.3.1.25
The remote error threshold Counter.
OBJECT-TYPE    
  Counter  

fraPStatRemMec 1.3.6.1.4.1.251.1.1.9.3.1.26
The remote monitored event Counter.
OBJECT-TYPE    
  Counter  

fraPStatRemPoll 1.3.6.1.4.1.251.1.1.9.3.1.27
The remote poll Counter for DTE.
OBJECT-TYPE    
  Counter  

fraPStatLastChangeM2 1.3.6.1.4.1.251.1.1.9.3.1.29
The date and time of last state change.
OBJECT-TYPE    
  DateAndTime  

fraPConfigTable 1.3.6.1.4.1.251.1.1.9.4
OBJECT-TYPE    
  SEQUENCE OF  
    FraPConfigEntry

fraPConfigEntry 1.3.6.1.4.1.251.1.1.9.4.1
OBJECT-TYPE    
  FraPConfigEntry  

fraPConfigDlci 1.3.6.1.4.1.251.1.1.9.4.1.1
This is the DLCI for the PVC.
OBJECT-TYPE    
  INTEGER 16..511  

fraPConfigCir 1.3.6.1.4.1.251.1.1.9.4.1.2
The committed information rate.
OBJECT-TYPE    
  INTEGER  

fraPConfigCommitB 1.3.6.1.4.1.251.1.1.9.4.1.3
The committed burst rate.
OBJECT-TYPE    
  INTEGER  

fraPConfigExcessB 1.3.6.1.4.1.251.1.1.9.4.1.4
The excess burst size.
OBJECT-TYPE    
  INTEGER  

fraVpi 1.3.6.1.4.1.251.1.1.9.4.1.5
The VPI for this call.
OBJECT-TYPE    
  VirtualPathIdentifier  

fraVci 1.3.6.1.4.1.251.1.1.9.4.1.6
The VCI for the call.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

fraPConfigPriority 1.3.6.1.4.1.251.1.1.9.4.1.7
OBJECT-TYPE    
  INTEGER  

fraPConfigSuba 1.3.6.1.4.1.251.1.1.9.4.1.8
OBJECT-TYPE    
  INTEGER  

fraPConfigSaddr 1.3.6.1.4.1.251.1.1.9.4.1.9
OBJECT-TYPE    
  INTEGER  

fraPConfigValidity 1.3.6.1.4.1.251.1.1.9.4.1.10
Provides a way of deleting a row in the table when set to invalid.
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

fraPConfigDxivpi 1.3.6.1.4.1.251.1.1.9.4.1.11
This is the VPI for the PVC
OBJECT-TYPE    
  INTEGER 0..7  

fraPConfigDxivci 1.3.6.1.4.1.251.1.1.9.4.1.12
This is the VCI for the PVC
OBJECT-TYPE    
  INTEGER 0..63  

fraPConfigDximode 1.3.6.1.4.1.251.1.1.9.4.1.13
This flag indicates whether the mode is DXI - in that case the value of DLCI is ignored
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

frbPStatTable 1.3.6.1.4.1.251.1.1.9.5
This table shows statistics about the Frame Relay PVCs for link 1.
OBJECT-TYPE    
  SEQUENCE OF  
    FrbPStatEntry

frbPStatEntry 1.3.6.1.4.1.251.1.1.9.5.1
OBJECT-TYPE    
  FrbPStatEntry  

frbPStatDlci 1.3.6.1.4.1.251.1.1.9.5.1.1
This is the DLCI for the PVC.
OBJECT-TYPE    
  INTEGER 16..511  

frbPStatRxBCnt 1.3.6.1.4.1.251.1.1.9.5.1.2
The number of bytes received.
OBJECT-TYPE    
  Counter  

frbPStatTxBCnt 1.3.6.1.4.1.251.1.1.9.5.1.3
The number of bytes transmitted.
OBJECT-TYPE    
  Counter  

frbPStatRxFCnt 1.3.6.1.4.1.251.1.1.9.5.1.4
The number of frames received.
OBJECT-TYPE    
  Counter  

frbPStatTxFCnt 1.3.6.1.4.1.251.1.1.9.5.1.5
The number of frames transmitted.
OBJECT-TYPE    
  Counter  

frbPStatRxBRate 1.3.6.1.4.1.251.1.1.9.5.1.6
The rate of bytes being received.
OBJECT-TYPE    
  Gauge  

frbPStatTxBRate 1.3.6.1.4.1.251.1.1.9.5.1.7
The rate of bytes being transmitted.
OBJECT-TYPE    
  Gauge  

frbPStatRxFRate 1.3.6.1.4.1.251.1.1.9.5.1.8
The rate of frames being received.
OBJECT-TYPE    
  Gauge  

frbPStatTxFRate 1.3.6.1.4.1.251.1.1.9.5.1.9
The rate of frames being transmitted.
OBJECT-TYPE    
  Gauge  

frbPStatDERxF 1.3.6.1.4.1.251.1.1.9.5.1.10
The count of discarded eligible received frames.
OBJECT-TYPE    
  Counter  

frbPStatDisRxF 1.3.6.1.4.1.251.1.1.9.5.1.11
The count of discarded received frames.
OBJECT-TYPE    
  Counter  

frbPStatPvcStat 1.3.6.1.4.1.251.1.1.9.5.1.12
The state of the PVC.
OBJECT-TYPE    
  Hex  

frbPStatLinkState 1.3.6.1.4.1.251.1.1.9.5.1.13
The state of the link.
OBJECT-TYPE    
  Hex  

frbPStatLocSeq 1.3.6.1.4.1.251.1.1.9.5.1.14
The local send sequence.
OBJECT-TYPE    
  INTEGER  

frbPStatLocAck 1.3.6.1.4.1.251.1.1.9.5.1.15
The local acknowledge number.
OBJECT-TYPE    
  INTEGER  

frbPStatLocStat 1.3.6.1.4.1.251.1.1.9.5.1.16
The local state of the link.
OBJECT-TYPE    
  INTEGER  

frbPStatLocStartT 1.3.6.1.4.1.251.1.1.9.5.1.17
The local start time for poll.
OBJECT-TYPE    
  INTEGER  

frbPStatLocErrThr 1.3.6.1.4.1.251.1.1.9.5.1.18
The local error threshold Counter.
OBJECT-TYPE    
  Counter  

frbPStatLocMec 1.3.6.1.4.1.251.1.1.9.5.1.19
The local monitored event Counter.
OBJECT-TYPE    
  Counter  

frbPStatLocPoll 1.3.6.1.4.1.251.1.1.9.5.1.20
The local poll Counter for DTE.
OBJECT-TYPE    
  Counter  

frbPStatRemSeq 1.3.6.1.4.1.251.1.1.9.5.1.21
The remote send sequence.
OBJECT-TYPE    
  INTEGER  

frbPStatRemAck 1.3.6.1.4.1.251.1.1.9.5.1.22
The remote acknowledge number.
OBJECT-TYPE    
  INTEGER  

frbPStatRemStat 1.3.6.1.4.1.251.1.1.9.5.1.23
The remote state of the link.
OBJECT-TYPE    
  INTEGER  

frbPStatRemStartT 1.3.6.1.4.1.251.1.1.9.5.1.24
The remote start time for poll.
OBJECT-TYPE    
  INTEGER  

frbPStatRemErrThr 1.3.6.1.4.1.251.1.1.9.5.1.25
The remote error threshold Counter.
OBJECT-TYPE    
  Counter  

frbPStatRemMec 1.3.6.1.4.1.251.1.1.9.5.1.26
The remote monitored event Counter.
OBJECT-TYPE    
  Counter  

frbPStatRemPoll 1.3.6.1.4.1.251.1.1.9.5.1.27
The remote poll Counter for DTE.
OBJECT-TYPE    
  Counter  

frbPStatLastChangeM2 1.3.6.1.4.1.251.1.1.9.5.1.29
The date and time of last state change.
OBJECT-TYPE    
  DateAndTime  

frbPConfigTable 1.3.6.1.4.1.251.1.1.9.6
OBJECT-TYPE    
  SEQUENCE OF  
    FrbPConfigEntry

frbPConfigEntry 1.3.6.1.4.1.251.1.1.9.6.1
OBJECT-TYPE    
  FrbPConfigEntry  

frbPConfigDlci 1.3.6.1.4.1.251.1.1.9.6.1.1
This is the DLCI for the PVC.
OBJECT-TYPE    
  INTEGER 16..511  

frbPConfigCir 1.3.6.1.4.1.251.1.1.9.6.1.2
The committed information rate.
OBJECT-TYPE    
  INTEGER  

frbPConfigCommitB 1.3.6.1.4.1.251.1.1.9.6.1.3
The committed burst rate.
OBJECT-TYPE    
  INTEGER  

frbPConfigExcessB 1.3.6.1.4.1.251.1.1.9.6.1.4
The excess burst size.
OBJECT-TYPE    
  INTEGER  

frbVpi 1.3.6.1.4.1.251.1.1.9.6.1.5
The VPI for this call.
OBJECT-TYPE    
  VirtualPathIdentifier  

frbVci 1.3.6.1.4.1.251.1.1.9.6.1.6
The VCI for the call.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

frbPConfigPriority 1.3.6.1.4.1.251.1.1.9.6.1.7
OBJECT-TYPE    
  INTEGER  

frbPConfigSuba 1.3.6.1.4.1.251.1.1.9.6.1.8
OBJECT-TYPE    
  INTEGER  

frbPConfigSaddr 1.3.6.1.4.1.251.1.1.9.6.1.9
OBJECT-TYPE    
  INTEGER  

frbPConfigValidity 1.3.6.1.4.1.251.1.1.9.6.1.10
Provides a way of deleting a row in the table when set to invalid.
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

frbPConfigDxivpi 1.3.6.1.4.1.251.1.1.9.6.1.11
This is the VPI for the PVC
OBJECT-TYPE    
  INTEGER 0..7  

frbPConfigDxivci 1.3.6.1.4.1.251.1.1.9.6.1.12
This is the VCI for the PVC
OBJECT-TYPE    
  INTEGER 0..63  

frbPConfigDximode 1.3.6.1.4.1.251.1.1.9.6.1.13
This flag indicates whether the mode is DXI - in that case the value of DLCI is ignored
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dv2VcStatus 1.3.6.1.4.1.251.1.1.10
OBJECT IDENTIFIER    

vcaTable 1.3.6.1.4.1.251.1.1.10.3
This table shows detailed status for native ATM slot controller card link A VCs.
OBJECT-TYPE    
  SEQUENCE OF  
    VcaEntry

vcaEntry 1.3.6.1.4.1.251.1.1.10.3.1
OBJECT-TYPE    
  VcaEntry  

vcaVpi 1.3.6.1.4.1.251.1.1.10.3.1.1
Virtual path identifier for the VC.
OBJECT-TYPE    
  INTEGER 0..4095  

vcaVci 1.3.6.1.4.1.251.1.1.10.3.1.2
Virtual channel identifier for the VC.
OBJECT-TYPE    
  INTEGER 0..65535  

vcaTxGCells 1.3.6.1.4.1.251.1.1.10.3.1.3
Number of transmitted good cells CLP0.
OBJECT-TYPE    
  Counter  

vcaTxGCellsClp1 1.3.6.1.4.1.251.1.1.10.3.1.4
Number of transmitted good cells CLP1.
OBJECT-TYPE    
  Counter  

vcaRxGCells 1.3.6.1.4.1.251.1.1.10.3.1.5
Number of received good cells.
OBJECT-TYPE    
  Counter  

vcaExcessCells 1.3.6.1.4.1.251.1.1.10.3.1.6
Number of cells discarded because of bucket overflow.
OBJECT-TYPE    
  Counter  

vcaPeakExceeds 1.3.6.1.4.1.251.1.1.10.3.1.7
Number of cells discarded because of peak cell rate violation.
OBJECT-TYPE    
  Counter  

vcaCellHead 1.3.6.1.4.1.251.1.1.10.3.1.8
This value is bitwise OR'd with the cell header.
OBJECT-TYPE    
  Hex  

vcaCellMask 1.3.6.1.4.1.251.1.1.10.3.1.9
This value is bitwise AND'd with the cell header.
OBJECT-TYPE    
  Hex  

vcaCellSwitchHead 1.3.6.1.4.1.251.1.1.10.3.1.10
This comprises a tag which is added to the cell before putting into the cell switch and a control byte.
OBJECT-TYPE    
  Hex  

vcaStartTime 1.3.6.1.4.1.251.1.1.10.3.1.11
This is the bucket start time.
OBJECT-TYPE    
  INTEGER  

vcaBucketControl 1.3.6.1.4.1.251.1.1.10.3.1.12
This is the bucket control register value.
OBJECT-TYPE    
  Hex  

vcaBucket0CV 1.3.6.1.4.1.251.1.1.10.3.1.13
The current value of bucket 0.
OBJECT-TYPE    
  Gauge  

vcaBucket0Max 1.3.6.1.4.1.251.1.1.10.3.1.14
The maximum value of bucket 0.
OBJECT-TYPE    
  Gauge  

vcaBucket0Inc 1.3.6.1.4.1.251.1.1.10.3.1.15
The bucket 0 increment value.
OBJECT-TYPE    
  INTEGER  

vcaBucket1CV 1.3.6.1.4.1.251.1.1.10.3.1.16
The current value of bucket 1.
OBJECT-TYPE    
  Gauge  

vcaBucket1Max 1.3.6.1.4.1.251.1.1.10.3.1.17
The maximum value of bucket 1.
OBJECT-TYPE    
  Gauge  

vcaBucket1Inc 1.3.6.1.4.1.251.1.1.10.3.1.18
The bucket 1 increment value.
OBJECT-TYPE    
  INTEGER  

vcaBucket2CV 1.3.6.1.4.1.251.1.1.10.3.1.19
The current value of bucket 2.
OBJECT-TYPE    
  Gauge  

vcaBucket2Max 1.3.6.1.4.1.251.1.1.10.3.1.20
The maximum value of bucket 2.
OBJECT-TYPE    
  Gauge  

vcaBucket2Inc 1.3.6.1.4.1.251.1.1.10.3.1.21
The bucket 2 increment value.
OBJECT-TYPE    
  INTEGER  

vcaBucket3CV 1.3.6.1.4.1.251.1.1.10.3.1.22
The current value of bucket 3.
OBJECT-TYPE    
  Gauge  

vcaBucket3Max 1.3.6.1.4.1.251.1.1.10.3.1.23
The maximum value of bucket 3.
OBJECT-TYPE    
  Gauge  

vcaBucket3Inc 1.3.6.1.4.1.251.1.1.10.3.1.24
The bucket 3 increment value.
OBJECT-TYPE    
  INTEGER  

vcaType 1.3.6.1.4.1.251.1.1.10.3.1.25
Virtual channel type for the VC.
OBJECT-TYPE    
  INTEGER mgmt-vc(3), sr-pp-pvc(2), sr-pp-pvp(6), sr-mp-bi-pvc(10), sr-mp-bi-pvp(14), sr-mp-uni-pvc(26), sr-mp-uni-pvp(30), sr-pp-svc(1), sr-pp-svp(5), sr-mp-bi-svc(9), sr-mp-bi-svp(13), sr-mp-uni-svc(25), sr-mp-uni-svp(29), ds-pp-pvc(34), ds-pp-pvp(38), ds-mp-bi-pvc(42), ds-mp-bi-pvp(46), ds-mp-uni-pvc(58), ds-mp-uni-pvp(62), ds-pp-svc(33), ds-pp-svp(37), ds-mp-bi-svc(41), ds-mp-bi-svp(45), ds-mp-uni-svc(57), ds-mp-uni-svp(61)  

vcaDstSlot 1.3.6.1.4.1.251.1.1.10.3.1.26
slot # this VC is going to
OBJECT-TYPE    
  INTEGER  


vcaDstVpi 1.3.6.1.4.1.251.1.1.10.3.1.28
VPI this VC is destined for.
OBJECT-TYPE    
  INTEGER  

vcaDstVci 1.3.6.1.4.1.251.1.1.10.3.1.29
VCI for this VC is destined for.
OBJECT-TYPE    
  INTEGER  

vcaInternalVpi 1.3.6.1.4.1.251.1.1.10.3.1.30
Internal VPI
OBJECT-TYPE    
  INTEGER  

vcaInternalVci 1.3.6.1.4.1.251.1.1.10.3.1.31
Internal VCI
OBJECT-TYPE    
  INTEGER  

vcbTable 1.3.6.1.4.1.251.1.1.10.4
This table shows detailed status for native ATM slot controller card link B VCs.
OBJECT-TYPE    
  SEQUENCE OF  
    VcbEntry

vcbEntry 1.3.6.1.4.1.251.1.1.10.4.1
OBJECT-TYPE    
  VcbEntry  

vcbVpi 1.3.6.1.4.1.251.1.1.10.4.1.1
Virtual path identifier for the VC.
OBJECT-TYPE    
  INTEGER 0..4095  

vcbVci 1.3.6.1.4.1.251.1.1.10.4.1.2
Virtual channel identifier for the VC.
OBJECT-TYPE    
  INTEGER 0..65535  

vcbTxGCells 1.3.6.1.4.1.251.1.1.10.4.1.3
Number of transmitted good cells CLP0.
OBJECT-TYPE    
  Counter  

vcbTxGCellsClp1 1.3.6.1.4.1.251.1.1.10.4.1.4
Number of transmitted good cells CLP1.
OBJECT-TYPE    
  Counter  

vcbRxGCells 1.3.6.1.4.1.251.1.1.10.4.1.5
Number of received good cells.
OBJECT-TYPE    
  Counter  

vcbExcessCells 1.3.6.1.4.1.251.1.1.10.4.1.6
Number of cells discarded because of bucket overflow.
OBJECT-TYPE    
  Counter  

vcbPeakExceeds 1.3.6.1.4.1.251.1.1.10.4.1.7
Number of cells discarded because of peak cell rate violation.
OBJECT-TYPE    
  Counter  

vcbCellHead 1.3.6.1.4.1.251.1.1.10.4.1.8
This value is bitwise OR'd with the cell header.
OBJECT-TYPE    
  Hex  

vcbCellMask 1.3.6.1.4.1.251.1.1.10.4.1.9
This value is bitwise AND'd with the cell header.
OBJECT-TYPE    
  Hex  

vcbCellSwitchHead 1.3.6.1.4.1.251.1.1.10.4.1.10
This comprises a tag which is added to the cell before putting into the cell switch and a control byte.
OBJECT-TYPE    
  Hex  

vcbStartTime 1.3.6.1.4.1.251.1.1.10.4.1.11
This is the bucket start time.
OBJECT-TYPE    
  INTEGER  

vcbBucketControl 1.3.6.1.4.1.251.1.1.10.4.1.12
This is the bucket control register value.
OBJECT-TYPE    
  Hex  

vcbBucket0CV 1.3.6.1.4.1.251.1.1.10.4.1.13
The current value of bucket 0.
OBJECT-TYPE    
  Gauge  

vcbBucket0Max 1.3.6.1.4.1.251.1.1.10.4.1.14
The maximum value of bucket 0.
OBJECT-TYPE    
  Gauge  

vcbBucket0Inc 1.3.6.1.4.1.251.1.1.10.4.1.15
The bucket 0 increment value.
OBJECT-TYPE    
  INTEGER  

vcbBucket1CV 1.3.6.1.4.1.251.1.1.10.4.1.16
The current value of bucket 1.
OBJECT-TYPE    
  Gauge  

vcbBucket1Max 1.3.6.1.4.1.251.1.1.10.4.1.17
The maximum value of bucket 1.
OBJECT-TYPE    
  Gauge  

vcbBucket1Inc 1.3.6.1.4.1.251.1.1.10.4.1.18
The bucket 1 increment value.
OBJECT-TYPE    
  INTEGER  

vcbBucket2CV 1.3.6.1.4.1.251.1.1.10.4.1.19
The current value of bucket 2.
OBJECT-TYPE    
  Gauge  

vcbBucket2Max 1.3.6.1.4.1.251.1.1.10.4.1.20
The maximum value of bucket 2.
OBJECT-TYPE    
  Gauge  

vcbBucket2Inc 1.3.6.1.4.1.251.1.1.10.4.1.21
The bucket 2 increment value.
OBJECT-TYPE    
  INTEGER  

vcbBucket3CV 1.3.6.1.4.1.251.1.1.10.4.1.22
The current value of bucket 3.
OBJECT-TYPE    
  Gauge  

vcbBucket3Max 1.3.6.1.4.1.251.1.1.10.4.1.23
The maximum value of bucket 3.
OBJECT-TYPE    
  Gauge  

vcbBucket3Inc 1.3.6.1.4.1.251.1.1.10.4.1.24
The bucket 3 increment value.
OBJECT-TYPE    
  INTEGER  

vcbType 1.3.6.1.4.1.251.1.1.10.4.1.25
Virtual channel type for the VC.
OBJECT-TYPE    
  INTEGER mgmt-vc(3), sr-pp-pvc(2), sr-pp-pvp(6), sr-mp-bi-pvc(10), sr-mp-bi-pvp(14), sr-mp-uni-pvc(26), sr-mp-uni-pvp(30), sr-pp-svc(1), sr-pp-svp(5), sr-mp-bi-svc(9), sr-mp-bi-svp(13), sr-mp-uni-svc(25), sr-mp-uni-svp(29), ds-pp-pvc(34), ds-pp-pvp(38), ds-mp-bi-pvc(42), ds-mp-bi-pvp(46), ds-mp-uni-pvc(58), ds-mp-uni-pvp(62), ds-pp-svc(33), ds-pp-svp(37), ds-mp-bi-svc(41), ds-mp-bi-svp(45), ds-mp-uni-svc(57), ds-mp-uni-svp(61)  

vcbDstSlot 1.3.6.1.4.1.251.1.1.10.4.1.26
slot # this VC is going to
OBJECT-TYPE    
  INTEGER  


vcbDstVpi 1.3.6.1.4.1.251.1.1.10.4.1.28
VPI this VC is destined for.
OBJECT-TYPE    
  INTEGER  

vcbDstVci 1.3.6.1.4.1.251.1.1.10.4.1.29
VCI for this VC is destined for.
OBJECT-TYPE    
  INTEGER  

vcbInternalVpi 1.3.6.1.4.1.251.1.1.10.4.1.30
Internal VPI
OBJECT-TYPE    
  INTEGER  

vcbInternalVci 1.3.6.1.4.1.251.1.1.10.4.1.31
Internal VCI
OBJECT-TYPE    
  INTEGER  

xpStatTable 1.3.6.1.4.1.251.1.1.10.5
This table shows status of the switch fabric interface.
OBJECT-TYPE    
  SEQUENCE OF  
    XpStatEntry

xpStatEntry 1.3.6.1.4.1.251.1.1.10.5.1
OBJECT-TYPE    
  XpStatEntry  

xpIFace 1.3.6.1.4.1.251.1.1.10.5.1.1
Switch fabric interface number.
OBJECT-TYPE    
  INTEGER 0..1  

xpRXCells 1.3.6.1.4.1.251.1.1.10.5.1.2
Switch fabric received cell count.
OBJECT-TYPE    
  Counter  

xpTXCells 1.3.6.1.4.1.251.1.1.10.5.1.3
Switch fabric transmit cell count.
OBJECT-TYPE    
  Counter  

xpBadVpiVci 1.3.6.1.4.1.251.1.1.10.5.1.4
Number of cells with bad VCI/VPI received.
OBJECT-TYPE    
  Counter  

xpRxOverflow 1.3.6.1.4.1.251.1.1.10.5.1.5
Number of receiver overflows.
OBJECT-TYPE    
  Counter  

xpTxHighPrOver 1.3.6.1.4.1.251.1.1.10.5.1.6
Number of transmitted cells with high priority overflow.
OBJECT-TYPE    
  Counter  

xpTxLowPrOver 1.3.6.1.4.1.251.1.1.10.5.1.7
Number of transmitted cells with low priority overflow.
OBJECT-TYPE    
  Counter  

xpInputOverflow 1.3.6.1.4.1.251.1.1.10.5.1.8
Number of M68302 fabric input overflow cells.
OBJECT-TYPE    
  Counter  

xpDocErrors 1.3.6.1.4.1.251.1.1.10.5.1.9
Number of DOC errors.
OBJECT-TYPE    
  Counter  

xpLowPriorityFifo 1.3.6.1.4.1.251.1.1.10.5.1.10
Read transmit low priority FIFO count.
OBJECT-TYPE    
  Counter  

xpEgDiscCells 1.3.6.1.4.1.251.1.1.10.5.1.11
Read transmit discard cell count.
OBJECT-TYPE    
  Counter  

xpIgDiscCells 1.3.6.1.4.1.251.1.1.10.5.1.12
Read receive discard cell count.
OBJECT-TYPE    
  Counter  

dv2PLPP 1.3.6.1.4.1.251.1.1.11
OBJECT IDENTIFIER    

plppCTable 1.3.6.1.4.1.251.1.1.11.1
This table is used to control PLPP configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppCEntry

plppCEntry 1.3.6.1.4.1.251.1.1.11.1.1
OBJECT-TYPE    
  PlppCEntry  

plppCLinkNo 1.3.6.1.4.1.251.1.1.11.1.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

plppCLinkEnab 1.3.6.1.4.1.251.1.1.11.1.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppCCPLCPMode 1.3.6.1.4.1.251.1.1.11.1.1.3
The PLCP mode for link.
OBJECT-TYPE    
  INTEGER none(1), e1(2), g751-e3(3), ds1(4), ds3(5), g832-e3(6)  

plppCDS3Framer 1.3.6.1.4.1.251.1.1.11.1.1.4
Set to yes(1) to enable the DS3 framer mode for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppCScrambler 1.3.6.1.4.1.251.1.1.11.1.1.5
Set to no(2) to disable the scrambler mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppC0x55 1.3.6.1.4.1.251.1.1.11.1.1.6
If set to no(2) then HCS is not XORed with 0x55
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppCCLine 1.3.6.1.4.1.251.1.1.11.1.1.7
Control line processing for this link.
OBJECT-TYPE    
  INTEGER processed(1), ignored(2)  

plppCLoopback 1.3.6.1.4.1.251.1.1.11.1.1.8
Set to yes(1) to enable loopback mode for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppCSmdsMode 1.3.6.1.4.1.251.1.1.11.1.1.12
Set to yes(1) to enable SMDS mode.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppCPloadTypeLab 1.3.6.1.4.1.251.1.1.11.1.1.13
Pay type label.
OBJECT-TYPE    
  INTEGER 0..7  

plppCTxTrlTrcIdLen 1.3.6.1.4.1.251.1.1.11.1.1.14
Trail trace length for transmit and expected receive.
OBJECT-TYPE    
  INTEGER l16(16), l64(64)  

plppCTxTrcId 1.3.6.1.4.1.251.1.1.11.1.1.15
Transmit trail trace identifier.
OBJECT-TYPE    
  PhysAddress SIZE(16..64)  

plppCRxExTrcId 1.3.6.1.4.1.251.1.1.11.1.1.16
Receive expected trail trace identifier.
OBJECT-TYPE    
  PhysAddress SIZE(16..64)  

plppSTable 1.3.6.1.4.1.251.1.1.11.2
The status table for plpp.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppSEntry

plppSEntry 1.3.6.1.4.1.251.1.1.11.2.1
OBJECT-TYPE    
  PlppSEntry  

plppSLinkNo 1.3.6.1.4.1.251.1.1.11.2.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

plppSCLines 1.3.6.1.4.1.251.1.1.11.2.1.2
The state of control lines for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppSTXclock 1.3.6.1.4.1.251.1.1.11.2.1.3
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppSRXclock 1.3.6.1.4.1.251.1.1.11.2.1.4
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppSTXCells 1.3.6.1.4.1.251.1.1.11.2.1.5
The transmit cells count for this link.
OBJECT-TYPE    
  Counter  

plppSRXCells 1.3.6.1.4.1.251.1.1.11.2.1.6
The receive cells count for this link.
OBJECT-TYPE    
  Counter  

plppSHCSErrs 1.3.6.1.4.1.251.1.1.11.2.1.7
The header checksum error count for this link.
OBJECT-TYPE    
  Counter  

plppSFrameErrs 1.3.6.1.4.1.251.1.1.11.2.1.11
The frame error count for this link.
OBJECT-TYPE    
  Counter  

plppSBIP8Errs 1.3.6.1.4.1.251.1.1.11.2.1.12
The BIP-8 error count for this link.
OBJECT-TYPE    
  Counter  

plppSFEBEErrs 1.3.6.1.4.1.251.1.1.11.2.1.13
The FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppSSPLRStatus 1.3.6.1.4.1.251.1.1.11.2.1.14
The SPLR Status Register Contents.
OBJECT-TYPE    
  INTEGER  

plppSDs3Lcvs 1.3.6.1.4.1.251.1.1.11.2.1.15
The DS3 LCV count for this link.
OBJECT-TYPE    
  Counter  

plppSDs3FrameErrs 1.3.6.1.4.1.251.1.1.11.2.1.16
The DS3 frame error count for this link.
OBJECT-TYPE    
  Counter  

plppSDs3ParityErrs 1.3.6.1.4.1.251.1.1.11.2.1.17
The DS3 parity error count for this link.
OBJECT-TYPE    
  Counter  

plppSDs3CbitPrtyErrs 1.3.6.1.4.1.251.1.1.11.2.1.18
The DS3 control bit parity error count for this link.
OBJECT-TYPE    
  Counter  

plppSDs3FEBEErrs 1.3.6.1.4.1.251.1.1.11.2.1.19
The DS3 FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppSDs3RxAIS 1.3.6.1.4.1.251.1.1.11.2.1.20
Receive DS3 AIS status.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppSDs3RxRedAlarm 1.3.6.1.4.1.251.1.1.11.2.1.21
Receive DS3 Red Alarm status.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppSDs3RxYellowAlarm 1.3.6.1.4.1.251.1.1.11.2.1.22
Receive DS3 Yellow Alarm status.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppSPLCPRxYellowAlarm 1.3.6.1.4.1.251.1.1.11.2.1.23
Receive PLCP Yellow Alarm status.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppsRxTrIdMis 1.3.6.1.4.1.251.1.1.11.2.1.24
Receive trace id mismatch indication.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppsRxTrIdUnst 1.3.6.1.4.1.251.1.1.11.2.1.25
Receive trace id unstable indication.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppsRxPloadTypeLabMis 1.3.6.1.4.1.251.1.1.11.2.1.26
Receive payload type label mismatch indication.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppsRxPloadTypeLabUnst 1.3.6.1.4.1.251.1.1.11.2.1.27
Receive payload type label unstable indication.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppsRxTrlTrc 1.3.6.1.4.1.251.1.1.11.2.1.28
Last received trail trace message.
OBJECT-TYPE    
  PhysAddress SIZE(16..64)  

plppV2CTable 1.3.6.1.4.1.251.1.1.11.3
This table is used to control DS3-2C PLPP configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppV2CEntry

plppV2CEntry 1.3.6.1.4.1.251.1.1.11.3.1
OBJECT-TYPE    
  PlppV2CEntry  

plppV2CLinkNo 1.3.6.1.4.1.251.1.1.11.3.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

plppV2CLinkEnab 1.3.6.1.4.1.251.1.1.11.3.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2CCPLCPMode 1.3.6.1.4.1.251.1.1.11.3.1.3
Set to yes(1) to enable the PLCP layer mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2CDS3Framer 1.3.6.1.4.1.251.1.1.11.3.1.4
Set to yes(1) to enable the DS3 framer mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2CScrambler 1.3.6.1.4.1.251.1.1.11.3.1.5
Set to no(2) to disable the scrambler mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2C0x55 1.3.6.1.4.1.251.1.1.11.3.1.6
If set to no(2) then HCS is not XORed with 0x55
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2CLoopback 1.3.6.1.4.1.251.1.1.11.3.1.7
Set to yes(1) to enable loopback mode for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2CSmdsMode 1.3.6.1.4.1.251.1.1.11.3.1.8
Set to yes(1) to enable SMDS mode.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2CFrmFmt 1.3.6.1.4.1.251.1.1.11.3.1.9
Set to yes(1) to enable C-bit parity framing format.
OBJECT-TYPE    
  INTEGER c-bit(1), clear-channel(2)  

plppV2CTxAIS 1.3.6.1.4.1.251.1.1.11.3.1.10
Set to yes(1) to enable framer to Txmt AIS.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2STable 1.3.6.1.4.1.251.1.1.11.4
The status table for DS3-2C plpp.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppV2SEntry

plppV2SEntry 1.3.6.1.4.1.251.1.1.11.4.1
OBJECT-TYPE    
  PlppV2SEntry  

plppV2SLinkNo 1.3.6.1.4.1.251.1.1.11.4.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

plppV2STXclock 1.3.6.1.4.1.251.1.1.11.4.1.2
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppV2SRXclock 1.3.6.1.4.1.251.1.1.11.4.1.3
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppV2STXCells 1.3.6.1.4.1.251.1.1.11.4.1.4
The transmit cells count for this link.
OBJECT-TYPE    
  Counter  

plppV2SRXCells 1.3.6.1.4.1.251.1.1.11.4.1.5
The receive cells count for this link.
OBJECT-TYPE    
  Counter  

plppV2SHCSErrs 1.3.6.1.4.1.251.1.1.11.4.1.6
The header checksum error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SFrameErrs 1.3.6.1.4.1.251.1.1.11.4.1.7
The frame error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SBIP8Errs 1.3.6.1.4.1.251.1.1.11.4.1.8
The BIP-8 error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SFEBEErrs 1.3.6.1.4.1.251.1.1.11.4.1.9
The FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SSPLRStatus 1.3.6.1.4.1.251.1.1.11.4.1.10
yes(1) indicates a PLCP LOF.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SDs3FrmFmt 1.3.6.1.4.1.251.1.1.11.4.1.11
Operate in DS3 C-bit Parity or drop-back to Clear Channel.
OBJECT-TYPE    
  INTEGER c-bit(1), clear-channel(2)  

plppV2SDs3Lcvs 1.3.6.1.4.1.251.1.1.11.4.1.12
The DS3 LCV count for this link.
OBJECT-TYPE    
  Counter  

plppV2SDs3FrameErrs 1.3.6.1.4.1.251.1.1.11.4.1.13
The DS3 frame error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SDs3ParityErrs 1.3.6.1.4.1.251.1.1.11.4.1.14
The DS3 parity error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SDs3CbitPrtyErrs 1.3.6.1.4.1.251.1.1.11.4.1.15
The DS3 control bit parity error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SDs3FEBEErrs 1.3.6.1.4.1.251.1.1.11.4.1.16
The DS3 FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppV2SDs3RxAIS 1.3.6.1.4.1.251.1.1.11.4.1.17
Receive DS3 AIS status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SDs3RxRedAlarm 1.3.6.1.4.1.251.1.1.11.4.1.18
Receive DS3 Red Alarm status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SDs3RxYellowAlarm 1.3.6.1.4.1.251.1.1.11.4.1.19
Receive DS3 Yellow Alarm status.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppV2SPLCPRxYellowAlarm 1.3.6.1.4.1.251.1.1.11.4.1.20
Receive PLCP Yellow Alarm status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SDs3FEACTxmt 1.3.6.1.4.1.251.1.1.11.4.1.21
Code that has been transmitted as a FEAC.
OBJECT-TYPE    
  INTEGER none(7), line-loopback-active(6), line-loopback-deactive(5), ds3-idl(4), ds3-ais(3), ds3-oof(2), ds3-los(1)  

plppV2SRxIDL 1.3.6.1.4.1.251.1.1.11.4.1.22
yes(1) indicates an IDLE has been received.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SLOC 1.3.6.1.4.1.251.1.1.11.4.1.23
Receive Loss of cell delineation.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppV2SDs3LPBK 1.3.6.1.4.1.251.1.1.11.4.1.24
if yes(1), the DS3 Framer is in loopback.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1CTable 1.3.6.1.4.1.251.1.1.11.5
This table to control the E1-2C PLPP configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppE1CEntry

plppE1CEntry 1.3.6.1.4.1.251.1.1.11.5.1
OBJECT-TYPE    
  PlppE1CEntry  

plppE1CLinkNo 1.3.6.1.4.1.251.1.1.11.5.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

plppE1CLinkEnab 1.3.6.1.4.1.251.1.1.11.5.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE1CScrambler 1.3.6.1.4.1.251.1.1.11.5.1.3
Set to no(2) to disable the scrambler mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE1C0x55 1.3.6.1.4.1.251.1.1.11.5.1.4
If set to no(2) then HCS is not XORed with 0x55
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE1CSmdsMode 1.3.6.1.4.1.251.1.1.11.5.1.5
Set to yes(1) to enable SMDS mode.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1CLpbk 1.3.6.1.4.1.251.1.1.11.5.1.6
Set to yes(1) to enable DOC Framer loopback.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1STable 1.3.6.1.4.1.251.1.1.11.6
The status table for E1-2C plpp.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppE1SEntry

plppE1SEntry 1.3.6.1.4.1.251.1.1.11.6.1
OBJECT-TYPE    
  PlppE1SEntry  

plppE1SLinkNo 1.3.6.1.4.1.251.1.1.11.6.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

plppE1STXclock 1.3.6.1.4.1.251.1.1.11.6.1.2
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppE1SRXclock 1.3.6.1.4.1.251.1.1.11.6.1.3
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

plppE1STXCells 1.3.6.1.4.1.251.1.1.11.6.1.4
The transmit cells count for this link.
OBJECT-TYPE    
  Counter  

plppE1SRXCells 1.3.6.1.4.1.251.1.1.11.6.1.5
The receive cells count for this link.
OBJECT-TYPE    
  Counter  

plppE1SHCSErrs 1.3.6.1.4.1.251.1.1.11.6.1.6
The HCS error count for this link.
OBJECT-TYPE    
  Counter  

plppE1SCRCErrs 1.3.6.1.4.1.251.1.1.11.6.1.7
The CRC-4 error count for this link.
OBJECT-TYPE    
  Counter  

plppE1SFrameErrs 1.3.6.1.4.1.251.1.1.11.6.1.8
The frame error count for this link.
OBJECT-TYPE    
  Counter  

plppE1SFEBEErrs 1.3.6.1.4.1.251.1.1.11.6.1.9
The FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppE1SLcvs 1.3.6.1.4.1.251.1.1.11.6.1.10
The E1 LCV count for this link.
OBJECT-TYPE    
  Counter  

plppE1SRxAIS 1.3.6.1.4.1.251.1.1.11.6.1.11
Receive E1 AIS status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1SRxOOF 1.3.6.1.4.1.251.1.1.11.6.1.12
Receive E1 OOF status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1SRxLOS 1.3.6.1.4.1.251.1.1.11.6.1.13
Receive E1 LOS status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1SRxLOF 1.3.6.1.4.1.251.1.1.11.6.1.14
Receive E1 LOF status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE1SFerf 1.3.6.1.4.1.251.1.1.11.6.1.15
Receiving a Far-End Receive Failure if yes.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3CTable 1.3.6.1.4.1.251.1.1.11.7
This table is used to control the E3-2C PLPP configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppE3CEntry

plppE3CEntry 1.3.6.1.4.1.251.1.1.11.7.1
OBJECT-TYPE    
  PlppE3CEntry  

plppE3CLinkNo 1.3.6.1.4.1.251.1.1.11.7.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

plppE3CLinkEnab 1.3.6.1.4.1.251.1.1.11.7.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE3CFramer 1.3.6.1.4.1.251.1.1.11.7.1.3
The E3 framer mode for the link.
OBJECT-TYPE    
  INTEGER g832(3), g751(2), none(1)  

plppE3CPLCPMode 1.3.6.1.4.1.251.1.1.11.7.1.4
The PLCP mode for the link.
OBJECT-TYPE    
  INTEGER none(1), g751(3)  

plppE3CScrambler 1.3.6.1.4.1.251.1.1.11.7.1.5
Set to no(2) to disable the scrambler mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE3C0x55 1.3.6.1.4.1.251.1.1.11.7.1.6
If set to no(2) then HCS is not XORed with 0x55
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE3CLoopback 1.3.6.1.4.1.251.1.1.11.7.1.7
Set to yes(1) to enable loopback mode for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3CSmdsMode 1.3.6.1.4.1.251.1.1.11.7.1.8
Set to yes(1) to enable SMDS mode.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3CTxmtTimMk 1.3.6.1.4.1.251.1.1.11.7.1.9
Set to yes(1) if traceable to primary ref clk.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

plppE3CPloadTypeLab 1.3.6.1.4.1.251.1.1.11.7.1.10
Payload type label.
OBJECT-TYPE    
  INTEGER atm(2)  

plppE3CTxTrlTrcIdLen 1.3.6.1.4.1.251.1.1.11.7.1.11
Trail trace length for transmit and expected receive.
OBJECT-TYPE    
  INTEGER length-16(16)  

plppE3CTxTrcIdUH 1.3.6.1.4.1.251.1.1.11.7.1.12
Transmit trail trace ID upper half.
OBJECT-TYPE    
  PhysAddress SIZE(8)  

plppE3CTxTrcIdLH 1.3.6.1.4.1.251.1.1.11.7.1.13
Transmit trail trace ID lower half.
OBJECT-TYPE    
  PhysAddress SIZE(8)  

plppE3CRxExTrcIdUH 1.3.6.1.4.1.251.1.1.11.7.1.14
Receive expected trail trace ID upper half.
OBJECT-TYPE    
  PhysAddress SIZE(8)  

plppE3CRxExTrcIdLH 1.3.6.1.4.1.251.1.1.11.7.1.15
Receive expected trail trace ID lower half.
OBJECT-TYPE    
  PhysAddress SIZE(8)  

plppE3STable 1.3.6.1.4.1.251.1.1.11.8
The E3-2C status table for plpp.
OBJECT-TYPE    
  SEQUENCE OF  
    PlppE3SEntry

plppE3SEntry 1.3.6.1.4.1.251.1.1.11.8.1
OBJECT-TYPE    
  PlppE3SEntry  

plppE3SLinkNo 1.3.6.1.4.1.251.1.1.11.8.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

plppE3STXclock 1.3.6.1.4.1.251.1.1.11.8.1.2
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER down(2), up(1)  

plppE3SRXclock 1.3.6.1.4.1.251.1.1.11.8.1.3
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER down(2), up(1)  

plppE3STXCells 1.3.6.1.4.1.251.1.1.11.8.1.4
The transmit cells count for this link.
OBJECT-TYPE    
  Counter  

plppE3SRXCells 1.3.6.1.4.1.251.1.1.11.8.1.5
The receive cells count for this link.
OBJECT-TYPE    
  Counter  

plppE3SHCSErrs 1.3.6.1.4.1.251.1.1.11.8.1.6
The header checksum error count for this link.
OBJECT-TYPE    
  Counter  

plppE3SE3FrameErrs 1.3.6.1.4.1.251.1.1.11.8.1.7
The E3 frame error count for this link.
OBJECT-TYPE    
  Counter  

plppE3SPLCPFrameErrs 1.3.6.1.4.1.251.1.1.11.8.1.8
The PLCP frame error count for this link.
OBJECT-TYPE    
  Counter  

plppE3SBIP8Errs 1.3.6.1.4.1.251.1.1.11.8.1.9
The BIP-8 error count for this link.
OBJECT-TYPE    
  Counter  

plppE3SFEBEErrs 1.3.6.1.4.1.251.1.1.11.8.1.10
The FEBE error count for this link.
OBJECT-TYPE    
  Counter  

plppE3SLcvs 1.3.6.1.4.1.251.1.1.11.8.1.11
The E3 LCV count for this link.
OBJECT-TYPE    
  Counter  

plppE3SLcd 1.3.6.1.4.1.251.1.1.11.8.1.12
Receive Loss of cell delineation.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxTrlTrc 1.3.6.1.4.1.251.1.1.11.8.1.13
Last received trail trace message.
OBJECT-TYPE    
  PhysAddress SIZE(16)  

plppE3SRxAIS 1.3.6.1.4.1.251.1.1.11.8.1.14
Receive E3 AIS status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxOOF 1.3.6.1.4.1.251.1.1.11.8.1.15
Receive E3 OOF status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxLOS 1.3.6.1.4.1.251.1.1.11.8.1.16
Receive E3 LOS status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxLOF 1.3.6.1.4.1.251.1.1.11.8.1.17
Receive E3 LOF status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxFERF 1.3.6.1.4.1.251.1.1.11.8.1.18
Receive E3 FERF status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SPLCPRxLof 1.3.6.1.4.1.251.1.1.11.8.1.19
The PLCP Rx LOF for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SPLCPRxYellowAlarm 1.3.6.1.4.1.251.1.1.11.8.1.20
Receive PLCP Yellow Alarm status.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxTrIdMis 1.3.6.1.4.1.251.1.1.11.8.1.21
Receive trace id mismatch indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxTrIdUnst 1.3.6.1.4.1.251.1.1.11.8.1.22
Receive trace id unstable indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxPloadTypeLabMis 1.3.6.1.4.1.251.1.1.11.8.1.23
Receive payload type label mismatch indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

plppE3SRxPloadTypeLabUnst 1.3.6.1.4.1.251.1.1.11.8.1.24
Receive payload type label unstable indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

dv2LocalFibre 1.3.6.1.4.1.251.1.1.12
OBJECT IDENTIFIER    

lFibreConfTable 1.3.6.1.4.1.251.1.1.12.1
This table contains configuration information for the LFDOC.
OBJECT-TYPE    
  SEQUENCE OF  
    LFibreConfEntry

lFibreConfEntry 1.3.6.1.4.1.251.1.1.12.1.1
OBJECT-TYPE    
  LFibreConfEntry  

lFibreConfLinkNo 1.3.6.1.4.1.251.1.1.12.1.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

lFibreConfLinkEnab 1.3.6.1.4.1.251.1.1.12.1.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

lFibreConfCLine 1.3.6.1.4.1.251.1.1.12.1.1.3
Set to ignored(2) to stop control line processing for this link.
OBJECT-TYPE    
  INTEGER processed(1), ignored(2)  

lFibreConfLoopback 1.3.6.1.4.1.251.1.1.12.1.1.4
Set to yes(1) to enable loopback mode for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

lFibreStatTable 1.3.6.1.4.1.251.1.1.12.2
This table contains status information for the LFDOC
OBJECT-TYPE    
  SEQUENCE OF  
    LFibreStatEntry

lFibreStatEntry 1.3.6.1.4.1.251.1.1.12.2.1
OBJECT-TYPE    
  LFibreStatEntry  

lFibreStatLinkNo 1.3.6.1.4.1.251.1.1.12.2.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

lFibreStatCLines 1.3.6.1.4.1.251.1.1.12.2.1.2
The state of control lines for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lFibreStatHCSErrs 1.3.6.1.4.1.251.1.1.12.2.1.3
The header checksum error count for this link.
OBJECT-TYPE    
  Counter  

dv2DS 1.3.6.1.4.1.251.1.1.13
OBJECT IDENTIFIER    

ds1Table 1.3.6.1.4.1.251.1.1.13.1
ds1 Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1Entry

ds1Entry 1.3.6.1.4.1.251.1.1.13.1.1
OBJECT-TYPE    
  Ds1Entry  

ds1LinkNo 1.3.6.1.4.1.251.1.1.13.1.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

ds1LineLength 1.3.6.1.4.1.251.1.1.13.1.1.2
Length of the line connected to the physical interface.
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-feet(7), square(8)  

ds1Framing 1.3.6.1.4.1.251.1.1.13.1.1.3
T1 Framing type.
OBJECT-TYPE    
  INTEGER none(1), sf(2), t1dm(3), slc96(4), esf4k(5), esf2k-3(6), esf2k-1(7)  

ds1Coding 1.3.6.1.4.1.251.1.1.13.1.1.4
The line code of incoming DS1 signal. ami(2) selects AMI line code.
OBJECT-TYPE    
  INTEGER b8zs(1), ami(2)  

ds1Tr 1.3.6.1.4.1.251.1.1.13.1.1.5
Set to yes(1) to enable transmit loop-back.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1Rt 1.3.6.1.4.1.251.1.1.13.1.1.6
Set to yes(1) to enable receive loop-back.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1LOSDefect 1.3.6.1.4.1.251.1.1.13.1.1.7
Loss of Signal Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1AISDefect 1.3.6.1.4.1.251.1.1.13.1.1.8
AIS Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1OOFDefect 1.3.6.1.4.1.251.1.1.13.1.1.9
OOF Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1YellowDefect 1.3.6.1.4.1.251.1.1.13.1.1.10
Yellow Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1LOSAlarm 1.3.6.1.4.1.251.1.1.13.1.1.11
Loss Of Signal alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1AISAlarm 1.3.6.1.4.1.251.1.1.13.1.1.12
AIS alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1LOFAlarm 1.3.6.1.4.1.251.1.1.13.1.1.13
Loss Of Frame alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1YellowAlarm 1.3.6.1.4.1.251.1.1.13.1.1.14
Yellow alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1PdvCount 1.3.6.1.4.1.251.1.1.13.1.1.15
Number of pulse density violations detected.
OBJECT-TYPE    
  Counter  

ds1Z16Count 1.3.6.1.4.1.251.1.1.13.1.1.16
Number of 16 consecutive zeroes detected.
OBJECT-TYPE    
  Counter  

ds1LcvCount 1.3.6.1.4.1.251.1.1.13.1.1.17
Number of line code violations detected.
OBJECT-TYPE    
  Counter  

ds1BeeCount 1.3.6.1.4.1.251.1.1.13.1.1.18
Number of block error events detected.
OBJECT-TYPE    
  Counter  

ds1FerCount 1.3.6.1.4.1.251.1.1.13.1.1.19
Number of framing bit error events detected.
OBJECT-TYPE    
  Counter  

ds1OofCount 1.3.6.1.4.1.251.1.1.13.1.1.20
Number of out of frame events detected.
OBJECT-TYPE    
  Counter  

ds1ClrStats 1.3.6.1.4.1.251.1.1.13.1.1.21
Clear counters
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1Reconfig 1.3.6.1.4.1.251.1.1.13.1.1.22
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1LineES 1.3.6.1.4.1.251.1.1.13.1.1.23
Line Errored Seconds
OBJECT-TYPE    
  Counter  

ds1LineSES 1.3.6.1.4.1.251.1.1.13.1.1.24
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

ds1ES 1.3.6.1.4.1.251.1.1.13.1.1.25
Errored Seconds
OBJECT-TYPE    
  Counter  

ds1SES 1.3.6.1.4.1.251.1.1.13.1.1.26
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

ds1AISS 1.3.6.1.4.1.251.1.1.13.1.1.27
AIS Seconds
OBJECT-TYPE    
  Counter  

ds1UAS 1.3.6.1.4.1.251.1.1.13.1.1.28
Unavailable Seconds
OBJECT-TYPE    
  Counter  

ds1TxClkSel 1.3.6.1.4.1.251.1.1.13.1.1.29
Transmit clock select.
OBJECT-TYPE    
  INTEGER local-oscillator(12), local-link(13)  

ds1ExBERDefect 1.3.6.1.4.1.251.1.1.13.1.1.30
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1ExBERAlarm 1.3.6.1.4.1.251.1.1.13.1.1.31
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3Table 1.3.6.1.4.1.251.1.1.13.2
ds3 Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3Entry

ds3Entry 1.3.6.1.4.1.251.1.1.13.2.1
OBJECT-TYPE    
  Ds3Entry  

ds3LinkNo 1.3.6.1.4.1.251.1.1.13.2.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

ds3Lb 1.3.6.1.4.1.251.1.1.13.2.1.2
Loop-back mode active.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3Err 1.3.6.1.4.1.251.1.1.13.2.1.3
AIS or BPV detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3RXLos 1.3.6.1.4.1.251.1.1.13.2.1.4
Receive loss of signal.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3TXLoc 1.3.6.1.4.1.251.1.1.13.2.1.5
Transmit loss of clock.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3RXErr 1.3.6.1.4.1.251.1.1.13.2.1.6
Receive error detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3RXAis 1.3.6.1.4.1.251.1.1.13.2.1.7
Set to yes(1) to generate a receive AIS alarm.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3TXAis 1.3.6.1.4.1.251.1.1.13.2.1.8
Set to yes(1) to transmit an AIS alarm.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3TXLev 1.3.6.1.4.1.251.1.1.13.2.1.9
Transmit level.
OBJECT-TYPE    
  INTEGER normal(1), high(2)  

ds3Tr 1.3.6.1.4.1.251.1.1.13.2.1.10
Transmit loop-back.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3Rt 1.3.6.1.4.1.251.1.1.13.2.1.11
Set to yes(1) to enable receive loop-back.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3Equal 1.3.6.1.4.1.251.1.1.13.2.1.12
Equalisation type.
OBJECT-TYPE    
  INTEGER short(1), long(2)  

ds3LOSAlarm 1.3.6.1.4.1.251.1.1.13.2.1.13
Loss Of Signal Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3Reconfig 1.3.6.1.4.1.251.1.1.13.2.1.14
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1Table 1.3.6.1.4.1.251.1.1.13.5
E1-2C Config/Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    E1Entry

e1Entry 1.3.6.1.4.1.251.1.1.13.5.1
OBJECT-TYPE    
  E1Entry  

e1LinkNo 1.3.6.1.4.1.251.1.1.13.5.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

e1LimType 1.3.6.1.4.1.251.1.1.13.5.1.2
LIM I.D. type
OBJECT-TYPE    
  INTEGER dual(1), quad(2), dual-sig(3), quad-sig(4)  

e1Lb 1.3.6.1.4.1.251.1.1.13.5.1.3
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), line(2), payload(3), digital(4)  

e1FRMRMode 1.3.6.1.4.1.251.1.1.13.5.1.4
e1 Framing options.
OBJECT-TYPE    
  INTEGER crc-mfrm(1), basic(2), unframed(3)  

e1TxClkSel 1.3.6.1.4.1.251.1.1.13.5.1.5
Transmit clock select.
OBJECT-TYPE    
  INTEGER system(11), loc-oscil(12), loc-link0(13), loc-link1(14), loc-link2(15), loc-link3(16)  

e1TS16PayLd 1.3.6.1.4.1.251.1.1.13.5.1.6
Employ TimeSlot 16 for customer data.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1TxAIS 1.3.6.1.4.1.251.1.1.13.5.1.7
Transmit the AIS State.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1GappedClk 1.3.6.1.4.1.251.1.1.13.5.1.8
Select 1,(yes) for Circuit-emulation.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1IntrfType 1.3.6.1.4.1.251.1.1.13.5.1.9
E1 Framing options.
OBJECT-TYPE    
  INTEGER balanc-120(1), unbalan-75(2)  

e1ClrStats 1.3.6.1.4.1.251.1.1.13.5.1.10
Clear Counters
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

e1Reconfig 1.3.6.1.4.1.251.1.1.13.5.1.11
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

se1SA4 1.3.6.1.4.1.251.1.1.13.5.1.12
Nat'l bit Sa4
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SA5 1.3.6.1.4.1.251.1.1.13.5.1.13
Nat'l bit Sa5
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SA6 1.3.6.1.4.1.251.1.1.13.5.1.14
Nat'l bit Sa6
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SA7 1.3.6.1.4.1.251.1.1.13.5.1.15
Nat'l bit Sa7
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SA8 1.3.6.1.4.1.251.1.1.13.5.1.16
Nat'l bit Sa8
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SI0 1.3.6.1.4.1.251.1.1.13.5.1.17
Int'l bit Si0
OBJECT-TYPE    
  INTEGER off(2), on(1)  

se1SI1 1.3.6.1.4.1.251.1.1.13.5.1.18
Nat'l bit Si1
OBJECT-TYPE    
  INTEGER off(2), on(1)  

e1LOSDefect 1.3.6.1.4.1.251.1.1.13.5.1.22
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1OOFDefect 1.3.6.1.4.1.251.1.1.13.5.1.23
Receive Out Of Frame
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1AISDefect 1.3.6.1.4.1.251.1.1.13.5.1.24
Receive AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1FerfDefect 1.3.6.1.4.1.251.1.1.13.5.1.25
Receive Yellow Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1ExBERDefect 1.3.6.1.4.1.251.1.1.13.5.1.26
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

e1LOSAlarm 1.3.6.1.4.1.251.1.1.13.5.1.37
Loss Of Signal Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1LOFAlarm 1.3.6.1.4.1.251.1.1.13.5.1.38
Loss Of Frame Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1AISAlarm 1.3.6.1.4.1.251.1.1.13.5.1.39
AIS Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1FerfAlarm 1.3.6.1.4.1.251.1.1.13.5.1.40
Yellow Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e1ExBERAlarm 1.3.6.1.4.1.251.1.1.13.5.1.41
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

e1SCRCErrs 1.3.6.1.4.1.251.1.1.13.5.1.52
The CRC-4 error count for this link.
OBJECT-TYPE    
  INTEGER  

e1SFrameErrs 1.3.6.1.4.1.251.1.1.13.5.1.53
The frame error count for this link.
OBJECT-TYPE    
  INTEGER  

e1SFEBEErrs 1.3.6.1.4.1.251.1.1.13.5.1.54
The FEBE error count for this link.
OBJECT-TYPE    
  INTEGER  

e1SLcvs 1.3.6.1.4.1.251.1.1.13.5.1.55
The E1 LCV count for this link.
OBJECT-TYPE    
  INTEGER  

e1LineES 1.3.6.1.4.1.251.1.1.13.5.1.66
Line Errored Seconds
OBJECT-TYPE    
  Counter  

e1LineSES 1.3.6.1.4.1.251.1.1.13.5.1.67
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

e1ES 1.3.6.1.4.1.251.1.1.13.5.1.68
Errored Seconds
OBJECT-TYPE    
  Counter  

e1SES 1.3.6.1.4.1.251.1.1.13.5.1.69
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

e1AISS 1.3.6.1.4.1.251.1.1.13.5.1.70
AIS Seconds
OBJECT-TYPE    
  Counter  

e1UAS 1.3.6.1.4.1.251.1.1.13.5.1.71
Unavailable Seconds
OBJECT-TYPE    
  Counter  

soTable 1.3.6.1.4.1.251.1.1.13.7
SOLIM/DELIM Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    SoEntry

soEntry 1.3.6.1.4.1.251.1.1.13.7.1
OBJECT-TYPE    
  SoEntry  

soLinkNo 1.3.6.1.4.1.251.1.1.13.7.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..1  

soLimType 1.3.6.1.4.1.251.1.1.13.7.1.2
Solim version
OBJECT-TYPE    
  INTEGER solim-v0(1), solim-v1(2), solim-v2(3)  

soTimingRef 1.3.6.1.4.1.251.1.1.13.7.1.3
Local timing reference
OBJECT-TYPE    
  INTEGER system(11), local-oscillator(12), local-link0(13), local-link1(14)  

soTxEn0 1.3.6.1.4.1.251.1.1.13.7.1.4
Link 0 Tx Enable (v2 and above)
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

soTxEn1 1.3.6.1.4.1.251.1.1.13.7.1.5
Link 1 Tx Enable (v2 and above)
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

soLimDesc 1.3.6.1.4.1.251.1.1.13.7.1.6
LIM Description
OBJECT-TYPE    
  INTEGER pre-system-timing(1), dual-intermediate-reach(2), single-intermediate-reach(3), dual-short-reach(4), single-short-reach(5), dual-long-reach(6), single-long-reach(7), dual-hybrid-intermediate(8), dual-hybrid-long(9), dual-electrical(10)  

soReconfig 1.3.6.1.4.1.251.1.1.13.7.1.7
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2Table 1.3.6.1.4.1.251.1.1.13.9
ds1 V2 Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1V2Entry

ds1V2Entry 1.3.6.1.4.1.251.1.1.13.9.1
OBJECT-TYPE    
  Ds1V2Entry  

ds1V2LinkNo 1.3.6.1.4.1.251.1.1.13.9.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

ds1V2LimType 1.3.6.1.4.1.251.1.1.13.9.1.2
LIM I.D. type
OBJECT-TYPE    
  INTEGER ds1-dual(1), ds1-quad(2), ds1-dual-signaling(3), ds1-quad-signaling(4)  

ds1V2TxLineLn 1.3.6.1.4.1.251.1.1.13.9.1.3
Select txmt line length.
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-feet(7), square(8)  

ds1V2FRMRMode 1.3.6.1.4.1.251.1.1.13.9.1.4
ds1V2 Framing options.
OBJECT-TYPE    
  INTEGER none(1), sf(2), t1dm(3), slc96(4), esf4k(5), esf2K-3(6), esf2k-1(7)  

ds1V2Coding 1.3.6.1.4.1.251.1.1.13.9.1.5
If Line Coding is yes(1), AMI is selected
OBJECT-TYPE    
  INTEGER b8zs(2), ami(1)  

ds1V2Lb 1.3.6.1.4.1.251.1.1.13.9.1.6
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), line-lpbk(2), payload-lpbk(3), digital-lpbk(4)  

ds1V2TxAIS 1.3.6.1.4.1.251.1.1.13.9.1.7
Transmit the AIS State.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2GappedClk 1.3.6.1.4.1.251.1.1.13.9.1.8
Select 1,(yes) for Circuit-emulation.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1V2TxClkSel 1.3.6.1.4.1.251.1.1.13.9.1.9
Transmit clock select.
OBJECT-TYPE    
  INTEGER system(11), local-oscillator(12), local-link0(13), local-link1(14), local-link2(15), local-link3(16)  

ds1V2ClrStats 1.3.6.1.4.1.251.1.1.13.9.1.10
Clear Counters
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds1V2Reconfig 1.3.6.1.4.1.251.1.1.13.9.1.11
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2LOSDefect 1.3.6.1.4.1.251.1.1.13.9.1.22
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2OOFDefect 1.3.6.1.4.1.251.1.1.13.9.1.23
Receive Out Of Frame
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2AISDefect 1.3.6.1.4.1.251.1.1.13.9.1.24
Receive AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2FerfDefect 1.3.6.1.4.1.251.1.1.13.9.1.25
Receive FERF(Yellow) Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2BERDefect 1.3.6.1.4.1.251.1.1.13.9.1.26
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2LOSAlarm 1.3.6.1.4.1.251.1.1.13.9.1.37
Loss Of Signal Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2LOFAlarm 1.3.6.1.4.1.251.1.1.13.9.1.38
Loss Of Frame Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2AISAlarm 1.3.6.1.4.1.251.1.1.13.9.1.39
AIS Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2FerfAlarm 1.3.6.1.4.1.251.1.1.13.9.1.40
Yellow Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2BERAlarm 1.3.6.1.4.1.251.1.1.13.9.1.41
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds1V2FerCount 1.3.6.1.4.1.251.1.1.13.9.1.52
The framing bit error count for this link.
OBJECT-TYPE    
  INTEGER  

ds1V2BeeCount 1.3.6.1.4.1.251.1.1.13.9.1.53
The bit error count for this link.
OBJECT-TYPE    
  INTEGER  

ds1V2OCfCount 1.3.6.1.4.1.251.1.1.13.9.1.54
The Out-of-frame or Change of Frame alignment error count for this link.
OBJECT-TYPE    
  INTEGER  

ds1V2LcvCount 1.3.6.1.4.1.251.1.1.13.9.1.55
The DS1 Line code violations count for this link.
OBJECT-TYPE    
  INTEGER  

ds1V2LineES 1.3.6.1.4.1.251.1.1.13.9.1.66
Line Errored Seconds
OBJECT-TYPE    
  Counter  

ds1V2LineSES 1.3.6.1.4.1.251.1.1.13.9.1.67
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

ds1V2ES 1.3.6.1.4.1.251.1.1.13.9.1.68
Errored Seconds
OBJECT-TYPE    
  Counter  

ds1V2SES 1.3.6.1.4.1.251.1.1.13.9.1.69
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

ds1V2AISS 1.3.6.1.4.1.251.1.1.13.9.1.70
AIS Seconds
OBJECT-TYPE    
  Counter  

ds1V2UAS 1.3.6.1.4.1.251.1.1.13.9.1.71
Unavailable Seconds
OBJECT-TYPE    
  Counter  

ds1V2ExBER 1.3.6.1.4.1.251.1.1.13.9.1.72
Excessive Bit Error Rate
OBJECT-TYPE    
  Counter  

dlimLpbkTimeout 1.3.6.1.4.1.251.1.1.13.10
This parameter is used to set the dlim loopback timeout in minutes.
OBJECT-TYPE    
  INTEGER 1..604800  

ds3V2Table 1.3.6.1.4.1.251.1.1.13.11
ds3-2C Config/Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3V2Entry

ds3V2Entry 1.3.6.1.4.1.251.1.1.13.11.1
OBJECT-TYPE    
  Ds3V2Entry  

ds3V2LinkNo 1.3.6.1.4.1.251.1.1.13.11.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

ds3V2Lb 1.3.6.1.4.1.251.1.1.13.11.1.2
Loopback Active
OBJECT-TYPE    
  INTEGER none(2), line-lpbk(1), local-lpbk(3)  

ds3V2LimType 1.3.6.1.4.1.251.1.1.13.11.1.3
LIM I.D. type
OBJECT-TYPE    
  INTEGER ds3-2c(1)  

ds3V2LimOK 1.3.6.1.4.1.251.1.1.13.11.1.4
LIM OK.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ds3V2TxLBO 1.3.6.1.4.1.251.1.1.13.11.1.5
Transmit line build-out,(1)for short cables.
OBJECT-TYPE    
  INTEGER short(1), long(2)  

ds3V2TxClkSel 1.3.6.1.4.1.251.1.1.13.11.1.6
Transmit clock select.
OBJECT-TYPE    
  INTEGER system(11), local-oscillator(12), link0-plcp(17), link1-plcp(18)  

ds3V2LOSDefect 1.3.6.1.4.1.251.1.1.13.11.1.8
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3V2LOSAlarm 1.3.6.1.4.1.251.1.1.13.11.1.9
Loss Of Signal Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ds3V2Reconfig 1.3.6.1.4.1.251.1.1.13.11.1.10
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e3Table 1.3.6.1.4.1.251.1.1.13.12
E3-2C Config/Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    E3Entry

e3Entry 1.3.6.1.4.1.251.1.1.13.12.1
OBJECT-TYPE    
  E3Entry  

e3LinkNo 1.3.6.1.4.1.251.1.1.13.12.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

e3LimType 1.3.6.1.4.1.251.1.1.13.12.1.2
LIM I.D. type
OBJECT-TYPE    
  INTEGER e3-2c(1)  

e3LimOK 1.3.6.1.4.1.251.1.1.13.12.1.3
LIM OK.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e3EQSelect 1.3.6.1.4.1.251.1.1.13.12.1.4
Rx Line Equalization select.
OBJECT-TYPE    
  INTEGER auto(1), set-0-to-3p5-dB(2), set-2p6-to-8-dB(3), set-6-to-9p9-dB(4), set-8p6-to-13p2-dB(5)  

e3Loopback 1.3.6.1.4.1.251.1.1.13.12.1.6
Loopback LIU.
OBJECT-TYPE    
  INTEGER none(3), line-lpbk(1), local-lpbk(2)  

e3TxAIS 1.3.6.1.4.1.251.1.1.13.12.1.7
Transmit AIS.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e3TxClkSel 1.3.6.1.4.1.251.1.1.13.12.1.8
Transmit clock select.
OBJECT-TYPE    
  INTEGER system(11), local-oscillator(12), local-link0(13), local-link1(14)  

e3LOSDefect 1.3.6.1.4.1.251.1.1.13.12.1.9
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e3LOSAlarm 1.3.6.1.4.1.251.1.1.13.12.1.10
Loss Of Signal Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

e3Reconfig 1.3.6.1.4.1.251.1.1.13.12.1.11
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

hssiTable 1.3.6.1.4.1.251.1.1.13.13
hssi Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    HssiEntry

hssiEntry 1.3.6.1.4.1.251.1.1.13.13.1
OBJECT-TYPE    
  HssiEntry  

hssiLinkNo 1.3.6.1.4.1.251.1.1.13.13.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

hssiLocalLoopback 1.3.6.1.4.1.251.1.1.13.13.1.2
Local Loopback.
OBJECT-TYPE    
  INTEGER none(1), line(2), internal(3), bilateral(4)  

hssiRemoteLoopback 1.3.6.1.4.1.251.1.1.13.13.1.3
Remote Loopback.
OBJECT-TYPE    
  INTEGER none(1), line(2), digital(3), remote-line(4)  

hssiReconfig 1.3.6.1.4.1.251.1.1.13.13.1.4
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

hssiType 1.3.6.1.4.1.251.1.1.13.13.1.15
Type of link.
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

hssiLimType 1.3.6.1.4.1.251.1.1.13.13.1.16
LIM Version
OBJECT-TYPE    
  INTEGER hssi-v1(1)  

hssiClockSrc 1.3.6.1.4.1.251.1.1.13.13.1.17
Source of clock. Note that for a DCE, from-DCE(4) should not be selected.
OBJECT-TYPE    
  INTEGER local(1), from-dce(2), local-45Mbps(3), local-34Mbps(4)  

hssiCtrTestMode 1.3.6.1.4.1.251.1.1.13.13.1.18
Test Mode.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

hssiLinkReady 1.3.6.1.4.1.251.1.1.13.13.1.19
Set to yes(1) if link is ready.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

hssiRemoteReady 1.3.6.1.4.1.251.1.1.13.13.1.20
Set to yes(1) if remote link is ready.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

hssiLOSDefect 1.3.6.1.4.1.251.1.1.13.13.1.25
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

hssiLOSAlarm 1.3.6.1.4.1.251.1.1.13.13.1.30
Loss Of Signal Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2Table 1.3.6.1.4.1.251.1.1.13.14
J2 Config/Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    J2Entry

j2Entry 1.3.6.1.4.1.251.1.1.13.14.1
OBJECT-TYPE    
  J2Entry  

j2LinkNo 1.3.6.1.4.1.251.1.1.13.14.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

j2FirmwareRev 1.3.6.1.4.1.251.1.1.13.14.1.3
Firmware Revision
OBJECT-TYPE    
  INTEGER  

j2TxEq 1.3.6.1.4.1.251.1.1.13.14.1.4
Select equalizer setting
OBJECT-TYPE    
  INTEGER low-dB(1), high-dB(2)  

j2Lb 1.3.6.1.4.1.251.1.1.13.14.1.6
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), liu-line(2), j2-Framer-Payload(3), j2-Framer-Digital(4)  

j2TxAIS 1.3.6.1.4.1.251.1.1.13.14.1.7
Transmit the AIS State.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2TxClkSel 1.3.6.1.4.1.251.1.1.13.14.1.9
Transmit clock select.
OBJECT-TYPE    
  INTEGER system-bus(11), int-oscillator(12), link-0(13), link-1(14)  

j2ClrStats 1.3.6.1.4.1.251.1.1.13.14.1.10
Clear Counters
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

j2Reconfig 1.3.6.1.4.1.251.1.1.13.14.1.11
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2TS97TS98 1.3.6.1.4.1.251.1.1.13.14.1.12
Set the value (in hex) of the bytes to be transmitted in time slots 97 and 98 of the J2 frame.
OBJECT-TYPE    
  Hex  

j2QualClock 1.3.6.1.4.1.251.1.1.13.14.1.20
Quality of Clock Selection
OBJECT-TYPE    
  INTEGER low-Primary(1), low-Secondary(2), high-Primary(3), high-Secondary(4), local-Oscillator(5)  

j2LOSDefect 1.3.6.1.4.1.251.1.1.13.14.1.22
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2OOFDefect 1.3.6.1.4.1.251.1.1.13.14.1.23
Receive Out Of Frame
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2AISDefect 1.3.6.1.4.1.251.1.1.13.14.1.24
Receive AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2RAlmDefect 1.3.6.1.4.1.251.1.1.13.14.1.26
Remote Alarm Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2LOSAlarm 1.3.6.1.4.1.251.1.1.13.14.1.37
Loss Of Signal Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2LOFAlarm 1.3.6.1.4.1.251.1.1.13.14.1.38
Loss Of Frame Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2AISAlarm 1.3.6.1.4.1.251.1.1.13.14.1.39
AIS Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2RAlmAlarm 1.3.6.1.4.1.251.1.1.13.14.1.41
Remote Alarm Condition
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

j2FerCount 1.3.6.1.4.1.251.1.1.13.14.1.52
The framing bit error count for this link.
OBJECT-TYPE    
  INTEGER  

j2RAlmCount 1.3.6.1.4.1.251.1.1.13.14.1.53
The Remote Alarm error count for this link.
OBJECT-TYPE    
  INTEGER  

j2LcvCount 1.3.6.1.4.1.251.1.1.13.14.1.55
The J2 Line code violations count for this link.
OBJECT-TYPE    
  INTEGER  

j2CrcCount 1.3.6.1.4.1.251.1.1.13.14.1.56
Number of J2 muliframes received with CRC errors
OBJECT-TYPE    
  Counter  

j2LineES 1.3.6.1.4.1.251.1.1.13.14.1.66
Line Errored Seconds
OBJECT-TYPE    
  Counter  

j2LineSES 1.3.6.1.4.1.251.1.1.13.14.1.67
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

j2ES 1.3.6.1.4.1.251.1.1.13.14.1.68
Errored Seconds
OBJECT-TYPE    
  Counter  

j2SES 1.3.6.1.4.1.251.1.1.13.14.1.69
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

j2AISS 1.3.6.1.4.1.251.1.1.13.14.1.70
AIS Seconds
OBJECT-TYPE    
  Counter  

j2UAS 1.3.6.1.4.1.251.1.1.13.14.1.71
Unavailable Seconds
OBJECT-TYPE    
  Counter  

scfTable 1.3.6.1.4.1.251.1.1.13.15
SCF Config/Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    ScfEntry

scfEntry 1.3.6.1.4.1.251.1.1.13.15.1
OBJECT-TYPE    
  ScfEntry  

scfLinkNo 1.3.6.1.4.1.251.1.1.13.15.1.1
Link number - this is the instance.
OBJECT-TYPE    
  INTEGER 0..3  

scfLimType 1.3.6.1.4.1.251.1.1.13.15.1.2
LIM I.D. type
OBJECT-TYPE    
  INTEGER si-dual(1), si-quad(2)  

scfFirmwareRev 1.3.6.1.4.1.251.1.1.13.15.1.3
Firmware Revision
OBJECT-TYPE    
  INTEGER  

scfQualClock 1.3.6.1.4.1.251.1.1.13.15.1.4
Quality of Clock Selection
OBJECT-TYPE    
  INTEGER low-Primary(1), low-Secondary(2), high-Primary(3), high-Secondary(4), local-Oscillator(5)  

scfContr 1.3.6.1.4.1.251.1.1.13.15.1.5
Controller Selection
OBJECT-TYPE    
  INTEGER ce-hpg-hc2(1), ms-ms2(2)  

scfDCEDTE 1.3.6.1.4.1.251.1.1.13.15.1.6
DCE or DTE Selection
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

scfLb 1.3.6.1.4.1.251.1.1.13.15.1.7
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), line(2), link(3), digital(4)  

scfLineTiming 1.3.6.1.4.1.251.1.1.13.15.1.8
Receive Line Timing Selection
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

scfDataRate 1.3.6.1.4.1.251.1.1.13.15.1.9
Data Rate Selection in K Bit/Sec
OBJECT-TYPE    
  INTEGER rate-2x4(1), rate-4x8(2), rate-7x2(3), rate-9x6(4), rate-14x4(5), rate-16x0(6), rate-16x6(7), rate-19x2(8), rate-28x8(9), rate-32x0(10), rate-38x4(11), rate-48x0(12), rate-50x0(13), rate-56x0(14), rate-57x6(15), rate-64x0(16), rate-76x8(17), rate-96x0(18), rate-112x0(19), rate-115x2(20), rate-128x0(21), rate-144x0(22), rate-153x6(23), rate-192x0(24), rate-224x0(25), rate-230x0(26), rate-256x0(27), rate-288x0(28), rate-307x2(29), rate-320x0(30), rate-384x0(31), rate-448x0(32), rate-512x0(33), rate-768x0(34), rate-1024x0(35), rate-1536x0(36), rate-1920x0(37), rate-2048x0(38), rate-3072x0(39), rate-4096x0(40), rate-6144x0(41), rate-8192x0(42)  

scfClkSel 1.3.6.1.4.1.251.1.1.13.15.1.10
Clock select
OBJECT-TYPE    
  INTEGER system(1), localOscillator(2)  

scfInterfaceType 1.3.6.1.4.1.251.1.1.13.15.1.11
Interface type selection
OBJECT-TYPE    
  INTEGER x21(1), rs449(2), eia530-A(3), v35(4)  

scfReconfig 1.3.6.1.4.1.251.1.1.13.15.1.12
Reconfigure Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

scfLOSDefect 1.3.6.1.4.1.251.1.1.13.15.1.13
Loss Of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

scfLOSAlarm 1.3.6.1.4.1.251.1.1.13.15.1.14
Loss Of Signal Integrated Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

dv2Billing 1.3.6.1.4.1.251.1.1.14
OBJECT IDENTIFIER    

billAvailable 1.3.6.1.4.1.251.1.1.14.1
Number of billing records available.
OBJECT-TYPE    
  INTEGER  

billingTable 1.3.6.1.4.1.251.1.1.14.3
This table is used to contain billing records.
OBJECT-TYPE    
  SEQUENCE OF  
    BillingEntry

billingEntry 1.3.6.1.4.1.251.1.1.14.3.1
OBJECT-TYPE    
  BillingEntry  

billSeq 1.3.6.1.4.1.251.1.1.14.3.1.1
billing record sequence number.
OBJECT-TYPE    
  INTEGER 0..2147483647  

billSvpi 1.3.6.1.4.1.251.1.1.14.3.1.2
Source Virtual Path Identifier for VC.
OBJECT-TYPE    
  VirtualPathIdentifier  

billSvci 1.3.6.1.4.1.251.1.1.14.3.1.3
Source Virtual Circuit Identifier for VC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

billDvpi 1.3.6.1.4.1.251.1.1.14.3.1.4
Destination Virtual Path Identifier for VC.
OBJECT-TYPE    
  VirtualPathIdentifier  

billDvci 1.3.6.1.4.1.251.1.1.14.3.1.5
Destination Virtual Circuit Identifier for VC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

billSslot 1.3.6.1.4.1.251.1.1.14.3.1.6
Source slot for VC.
OBJECT-TYPE    
  INTEGER  


billDslot 1.3.6.1.4.1.251.1.1.14.3.1.8
Destination slot for VC.
OBJECT-TYPE    
  INTEGER  


billCalled 1.3.6.1.4.1.251.1.1.14.3.1.10
Called or Destination E.164 address.
OBJECT-TYPE    
  E164  

billCalledSub 1.3.6.1.4.1.251.1.1.14.3.1.11
Called or Destination E.164 sub-address.
OBJECT-TYPE    
  E164SUB  

billCalling 1.3.6.1.4.1.251.1.1.14.3.1.12
Calling or Originating E.164 address.
OBJECT-TYPE    
  E164  

billCallingSub 1.3.6.1.4.1.251.1.1.14.3.1.13
Calling or Originating E.164 sub-address.
OBJECT-TYPE    
  E164SUB  

billCellInC 1.3.6.1.4.1.251.1.1.14.3.1.14
Cell in overflows count.
OBJECT-TYPE    
  Counter  

billCellIn 1.3.6.1.4.1.251.1.1.14.3.1.15
Cell in count.
OBJECT-TYPE    
  Counter  

billFrameIn 1.3.6.1.4.1.251.1.1.14.3.1.16
Frame in count.
OBJECT-TYPE    
  Counter  

billByteInC 1.3.6.1.4.1.251.1.1.14.3.1.17
Byte in overflows count.
OBJECT-TYPE    
  Counter  

billByteIn 1.3.6.1.4.1.251.1.1.14.3.1.18
Byte in count.
OBJECT-TYPE    
  Counter  

billCellOutC 1.3.6.1.4.1.251.1.1.14.3.1.19
Cell out overflows count.
OBJECT-TYPE    
  Counter  

billCellOut 1.3.6.1.4.1.251.1.1.14.3.1.20
Cell out count.
OBJECT-TYPE    
  Counter  

billFrameOut 1.3.6.1.4.1.251.1.1.14.3.1.21
Frame out count.
OBJECT-TYPE    
  Counter  

billByteOutC 1.3.6.1.4.1.251.1.1.14.3.1.22
Byte out overflows count.
OBJECT-TYPE    
  Counter  

billByteOut 1.3.6.1.4.1.251.1.1.14.3.1.23
Byte out count.
OBJECT-TYPE    
  Counter  

billCause 1.3.6.1.4.1.251.1.1.14.3.1.25
Clear cause code.
OBJECT-TYPE    
  INTEGER  

billValid 1.3.6.1.4.1.251.1.1.14.3.1.28
Deletes billing record Entry by setting to invalid(2).
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), block-invalid(3)  

billCLP1OutC 1.3.6.1.4.1.251.1.1.14.3.1.29
CLP1 out overflows count.
OBJECT-TYPE    
  Counter  

billCLP1Out 1.3.6.1.4.1.251.1.1.14.3.1.30
CLP1 out count.
OBJECT-TYPE    
  Counter  

billTag 1.3.6.1.4.1.251.1.1.14.3.1.31
This identifies the billable SVC.
OBJECT-TYPE    
  INTEGER  

billStartM2 1.3.6.1.4.1.251.1.1.14.3.1.32
Call start date-time.
OBJECT-TYPE    
  DateAndTime  

billEndM2 1.3.6.1.4.1.251.1.1.14.3.1.33
Call end date-time.
OBJECT-TYPE    
  DateAndTime  

billFwdPCR 1.3.6.1.4.1.251.1.1.14.3.1.34
SVC Forward Peak Cell Rate.
OBJECT-TYPE    
  INTEGER  

billBwdPCR 1.3.6.1.4.1.251.1.1.14.3.1.35
SVC Backward Peak Cell Rate.
OBJECT-TYPE    
  INTEGER  

billFwdSCR 1.3.6.1.4.1.251.1.1.14.3.1.36
SVC Forward Sustained Cell Rate.
OBJECT-TYPE    
  INTEGER  

billBwdSCR 1.3.6.1.4.1.251.1.1.14.3.1.37
SVC Backward Sustained Cell Rate.
OBJECT-TYPE    
  INTEGER  

billFwdMBS 1.3.6.1.4.1.251.1.1.14.3.1.38
SVC Forward Maximum Burst Size.
OBJECT-TYPE    
  INTEGER  

billBwdMBS 1.3.6.1.4.1.251.1.1.14.3.1.39
SVC Backward Maximum Burst Size.
OBJECT-TYPE    
  INTEGER  

billFwdQOS 1.3.6.1.4.1.251.1.1.14.3.1.40
Forward Quality of Service.
OBJECT-TYPE    
  INTEGER qos1(1), qos2(2), qos3(3), qos4(4), abr(6), cbr(7), vbrRt(8), vbrNrt(9)  

billBwdQOS 1.3.6.1.4.1.251.1.1.14.3.1.41
Backward Quality of Service.
OBJECT-TYPE    
  INTEGER qos1(1), qos2(2), qos3(3), qos4(4), abr(6), cbr(7), vbrRt(8), vbrNrt(9)  

billingControl 1.3.6.1.4.1.251.1.1.14.4
This object is set to start SPVC/PVC process.
OBJECT-TYPE    
  INTEGER stop-billing-process(1), start-SPVC-billing-process(2), start-PVC-billing-process(3), start-SPVC-and-PVC-billing(4), delete-all-billing-records(5), start-SVC-billing-process(6), start-SVC-and-PVC-billing(7)  

billLost 1.3.6.1.4.1.251.1.1.14.7
Lost of billing record count.
OBJECT-TYPE    
  Counter  


billTrapControl 1.3.6.1.4.1.251.1.1.14.9
This object is set to enable or disable billing traps
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

billDirControl 1.3.6.1.4.1.251.1.1.14.10
This object is selected for uni-direction billing or bi-direction billing.
OBJECT-TYPE    
  INTEGER uni-direction(1), bi-direction(2)  

billingInterval 1.3.6.1.4.1.251.1.1.14.12
This parameter is used to set the billing period in 15/30/60/120 minute intervals
OBJECT-TYPE    
  INTEGER period15min(1), period30min(2), period60min(3), period120min(4)  

dv2QeDoc 1.3.6.1.4.1.251.1.1.15
OBJECT IDENTIFIER    

qeDocMacAddress 1.3.6.1.4.1.251.1.1.15.1
MAC address of Ethernet ports.
OBJECT-TYPE    
  PhysAddress  

qeDocTunRetryPeriod 1.3.6.1.4.1.251.1.1.15.2
Number of seconds between retries of tunnel establishment.
OBJECT-TYPE    
  INTEGER 5..60  

qeDocTunIdlePeriod 1.3.6.1.4.1.251.1.1.15.3
Number of seconds to wait without activity before clearing tunnel call.
OBJECT-TYPE    
  INTEGER 5..3600  

qeDocBridgeTable 1.3.6.1.4.1.251.1.1.15.4
This table is used to statistics and control for the bridges.
OBJECT-TYPE    
  SEQUENCE OF  
    QeDocBridgeEntry

qeDocBridgeEntry 1.3.6.1.4.1.251.1.1.15.4.1
OBJECT-TYPE    
  QeDocBridgeEntry  

qeDocBridgeLinkNo 1.3.6.1.4.1.251.1.1.15.4.1.1
Link number.
OBJECT-TYPE    
  INTEGER 0..3  

qeDocBridgeEnable 1.3.6.1.4.1.251.1.1.15.4.1.2
Set to yes(1) to enable MAC bridging.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocBridgeLink0Eligible 1.3.6.1.4.1.251.1.1.15.4.1.3
Link 0 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocBridgeLink1Eligible 1.3.6.1.4.1.251.1.1.15.4.1.4
Link 1 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocBridgeLink2Eligible 1.3.6.1.4.1.251.1.1.15.4.1.5
Link 2 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocBridgeLink3Eligible 1.3.6.1.4.1.251.1.1.15.4.1.6
Link 3 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunTable 1.3.6.1.4.1.251.1.1.15.6
This table is used to establish and control tunnels set-up using SVCs.
OBJECT-TYPE    
  SEQUENCE OF  
    QeDocTunEntry

qeDocTunEntry 1.3.6.1.4.1.251.1.1.15.6.1
OBJECT-TYPE    
  QeDocTunEntry  

qeDocTunIndex 1.3.6.1.4.1.251.1.1.15.6.1.1
The tunnel index number.
OBJECT-TYPE    
  INTEGER 1..127  

qeDocTunName 1.3.6.1.4.1.251.1.1.15.6.1.2
Mnemonic name for tunnel.
OBJECT-TYPE    
  DisplayString  

qeDocTunType 1.3.6.1.4.1.251.1.1.15.6.1.3
Specifies the type of tunnel.
OBJECT-TYPE    
  INTEGER unused(1), ip(2), mac-bridge(3)  

qeDocTunState 1.3.6.1.4.1.251.1.1.15.6.1.4
Set to Use pvc(2) if using with a PVC. Set to Use svc(3) if using with a SVC. Set to idle(1) to prevent tunnel being established.
OBJECT-TYPE    
  INTEGER idle(1), use-pvc(2), use-svc(3), failed(4)  

qeDocTunCallState 1.3.6.1.4.1.251.1.1.15.6.1.5
State of tunnel call.
OBJECT-TYPE    
  INTEGER idle(1), allocated(2), waccept(3), active(4)  

qeDocTunInFrames 1.3.6.1.4.1.251.1.1.15.6.1.6
Received frames count.
OBJECT-TYPE    
  Counter  

qeDocTunOutFrames 1.3.6.1.4.1.251.1.1.15.6.1.7
Transmitted frames count.
OBJECT-TYPE    
  Counter  

qeDocTunVPI 1.3.6.1.4.1.251.1.1.15.6.1.8
VPI being used for the tunnel.
OBJECT-TYPE    
  VirtualPathIdentifier  

qeDocTunVCI 1.3.6.1.4.1.251.1.1.15.6.1.9
VCI being used for the tunnel.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

qeDocTunPriority 1.3.6.1.4.1.251.1.1.15.6.1.10
Cell priority bit value.
OBJECT-TYPE    
  INTEGER 0..1  

qeDocTunSlot 1.3.6.1.4.1.251.1.1.15.6.1.11
Target slot for tunnel.
OBJECT-TYPE    
  INTEGER 0..15  


qeDocTunRemNet 1.3.6.1.4.1.251.1.1.15.6.1.13
Remote network address for tunnel.
OBJECT-TYPE    
  IpAddress  

qeDocTunRemMask 1.3.6.1.4.1.251.1.1.15.6.1.14
Mask for remote network.
OBJECT-TYPE    
  IpAddress  

qeDocTunLocNet 1.3.6.1.4.1.251.1.1.15.6.1.15
Local network address for tunnel.
OBJECT-TYPE    
  IpAddress  

qeDocTunLocMask 1.3.6.1.4.1.251.1.1.15.6.1.16
Mask for local network.
OBJECT-TYPE    
  IpAddress  

qeDocTunRemStartSkt 1.3.6.1.4.1.251.1.1.15.6.1.17
Specifies start of socket range from remote that is allowed/barred from access to tunnel.
OBJECT-TYPE    
  INTEGER 1..65535  

qeDocTunRemEndSkt 1.3.6.1.4.1.251.1.1.15.6.1.18
Specifies end of socket range from remote that is allowed/barred from access to tunnel.
OBJECT-TYPE    
  INTEGER 1..65535  

qeDocTunLocStartSkt 1.3.6.1.4.1.251.1.1.15.6.1.19
Specifies start of socket range from local that is allowed/barred from access to tunnel.
OBJECT-TYPE    
  INTEGER 1..65535  

qeDocTunLocEndSkt 1.3.6.1.4.1.251.1.1.15.6.1.20
Specifies end of socket range from local that is allowed/barred from access to tunnel.
OBJECT-TYPE    
  INTEGER 1..65535  

qeDocTunSktType 1.3.6.1.4.1.251.1.1.15.6.1.21
Specifies the protocol type and whether to include or exclude frames with socket number in the specified range.
OBJECT-TYPE    
  INTEGER tcpInc-udpInc(4), tcpInc-udpExc(3), tcpExc-udpInc(2), tcpExc-udpExc(1)  

qeDocTunDestAddress 1.3.6.1.4.1.251.1.1.15.6.1.22
Destination address for tunnel. This is only required for SVC tunnels.
OBJECT-TYPE    
  E164  

qeDocTunDestSubAddress 1.3.6.1.4.1.251.1.1.15.6.1.23
Destination sub-address for tunnel. This is only required for SVC tunnels.
OBJECT-TYPE    
  E164SUB  

qeDocTunLink0Eligible 1.3.6.1.4.1.251.1.1.15.6.1.24
Link 0 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunLink1Eligible 1.3.6.1.4.1.251.1.1.15.6.1.25
Link 1 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunLink2Eligible 1.3.6.1.4.1.251.1.1.15.6.1.26
Link 2 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunLink3Eligible 1.3.6.1.4.1.251.1.1.15.6.1.27
Link 3 eligible for frames
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunValidity 1.3.6.1.4.1.251.1.1.15.6.1.28
Setting to invalid(2) removes the row from the table.
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

qeDocTunRfc1483Encap 1.3.6.1.4.1.251.1.1.15.6.1.29
Setting to yes(1) enable RFC 1483 LLC encapsulation.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

qeDocTunClp 1.3.6.1.4.1.251.1.1.15.6.1.31
Cell loss priority bit value.
OBJECT-TYPE    
  INTEGER 0..1  

qeDocIpAddress 1.3.6.1.4.1.251.1.1.15.7
The IP address of the QEDOC for management use.
OBJECT-TYPE    
  IpAddress  

qeDocIpMask 1.3.6.1.4.1.251.1.1.15.8
The mask for management use.
OBJECT-TYPE    
  IpAddress  

qeDocIpBCast 1.3.6.1.4.1.251.1.1.15.9
The management broadcast address.
OBJECT-TYPE    
  IpAddress  

dv2SDH 1.3.6.1.4.1.251.1.1.16
OBJECT IDENTIFIER    

sdhCTable 1.3.6.1.4.1.251.1.1.16.1
This table is used to control sdh/Sonet configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    SdhCEntry

sdhCEntry 1.3.6.1.4.1.251.1.1.16.1.1
OBJECT-TYPE    
  SdhCEntry  

sdhCLinkNo 1.3.6.1.4.1.251.1.1.16.1.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

sdhCLinkEnab 1.3.6.1.4.1.251.1.1.16.1.1.2
Set to yes(1) to enable the link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhCLoopTimer 1.3.6.1.4.1.251.1.1.16.1.1.3
Set to yes(1) to enable loop timing for this link.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

sdhCLoopDiag 1.3.6.1.4.1.251.1.1.16.1.1.4
Set to yes(1) to enable diagnostic loopback.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

sdhCLoopLine 1.3.6.1.4.1.251.1.1.16.1.1.5
Set to yes(1) to enable line loopback.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

sdhCScrambler 1.3.6.1.4.1.251.1.1.16.1.1.6
Set to no(2) to disable scramble mode for this link.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhC0x55 1.3.6.1.4.1.251.1.1.16.1.1.7
If set to no(2) then HCS is XORed with 0x55
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSonetSdh 1.3.6.1.4.1.251.1.1.16.1.1.8
If set to sdh(2) then sdh header is used
OBJECT-TYPE    
  INTEGER sonet(1), sdh(2)  

sdhClearCounts 1.3.6.1.4.1.251.1.1.16.1.1.9
Clear Error Counts and Performance Parameters
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

sdhReconfig 1.3.6.1.4.1.251.1.1.16.1.1.10
Perform Reconfiguration for Link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

sdhCLpbkTimeout 1.3.6.1.4.1.251.1.1.16.1.1.11
This parameter is used to set the loopback timeout in minutes.
OBJECT-TYPE    
  INTEGER 1..604800  

sdhStmSts 1.3.6.1.4.1.251.1.1.16.1.1.12
Set to 155.52(1) for STS-3c/STM-1 format
OBJECT-TYPE    
  INTEGER oc-3(1), oc-1(2)  

sdhAPSOnOff 1.3.6.1.4.1.251.1.1.16.1.1.13
If set to on(2) then sdh APS is used
OBJECT-TYPE    
  INTEGER off(1), on(2)  

sdhCIdleCell 1.3.6.1.4.1.251.1.1.16.1.1.14
Idle Cell Header Contents
OBJECT-TYPE    
  INTEGER unassigned(1), idle(2)  

sdhSTable 1.3.6.1.4.1.251.1.1.16.3
The status table for sdh/SONET.
OBJECT-TYPE    
  SEQUENCE OF  
    SdhSEntry

sdhSEntry 1.3.6.1.4.1.251.1.1.16.3.1
OBJECT-TYPE    
  SdhSEntry  

sdhSLinkNo 1.3.6.1.4.1.251.1.1.16.3.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

sdhSTXclock 1.3.6.1.4.1.251.1.1.16.3.1.2
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sdhSRXclock 1.3.6.1.4.1.251.1.1.16.3.1.3
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sdhSSectLOS 1.3.6.1.4.1.251.1.1.16.3.1.4
The loss of signal indicator.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSSectOOF 1.3.6.1.4.1.251.1.1.16.3.1.5
The out of frame indicator.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSSectLOF 1.3.6.1.4.1.251.1.1.16.3.1.6
The loss of frame indicator.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSLineAIS 1.3.6.1.4.1.251.1.1.16.3.1.7
Set to yes(1) if Line AIS detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSLineFERF 1.3.6.1.4.1.251.1.1.16.3.1.8
Set to yes(1) if Line FERF detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathAIS 1.3.6.1.4.1.251.1.1.16.3.1.9
Set to yes(1) if Alarm Indication Signal detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathYellow 1.3.6.1.4.1.251.1.1.16.3.1.10
Set to yes(1) if yellow alarm active.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathFERF 1.3.6.1.4.1.251.1.1.16.3.1.11
Set to yes(1) if Far End Receive Failure detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathLOP 1.3.6.1.4.1.251.1.1.16.3.1.12
Set to yes(1) if Loss Of Pointer detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathLabelMM 1.3.6.1.4.1.251.1.1.16.3.1.13
Set to yes(1) if a Path Label Mismatch is detected
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSExBERDefect 1.3.6.1.4.1.251.1.1.16.3.1.14
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSPathLabel 1.3.6.1.4.1.251.1.1.16.3.1.15
The Path Label.
OBJECT-TYPE    
  INTEGER atm(1), non-atm(2)  

sdhSCellDelState 1.3.6.1.4.1.251.1.1.16.3.1.16
The Cell Delineation State
OBJECT-TYPE    
  INTEGER hunt-or-presync(1), sync(2)  

sdhSAlarmLOS 1.3.6.1.4.1.251.1.1.16.3.1.17
Set to yes(1) if a LOS failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmLOF 1.3.6.1.4.1.251.1.1.16.3.1.18
Set to yes(1) if a LOF failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmLineAIS 1.3.6.1.4.1.251.1.1.16.3.1.19
Set to yes(1) if a Line AIS failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmLineRFI 1.3.6.1.4.1.251.1.1.16.3.1.20
Set to yes(1) if a Line Remote Failure Indication (Yellow Alarm) failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmPathAIS 1.3.6.1.4.1.251.1.1.16.3.1.21
Set to yes(1) if a Path AIS failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmPathRFI 1.3.6.1.4.1.251.1.1.16.3.1.22
Set to yes(1) if a Path Remote Failure Indication (Yellow Alarm) failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmLOP 1.3.6.1.4.1.251.1.1.16.3.1.23
Set to yes(1) if a LOP failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSAlarmPLM 1.3.6.1.4.1.251.1.1.16.3.1.24
Set to yes(1) if a Payload Mismatch failure is declared
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSExBERAlarm 1.3.6.1.4.1.251.1.1.16.3.1.25
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

sdhSCorrHCS 1.3.6.1.4.1.251.1.1.16.3.1.26
The correctable HCS errors count.
OBJECT-TYPE    
  Counter  

sdhSUnCorrHCS 1.3.6.1.4.1.251.1.1.16.3.1.27
The uncorrectable HCS errors count.
OBJECT-TYPE    
  Counter  

sdhS2Table 1.3.6.1.4.1.251.1.1.16.4
The second status table for sdh/SONET.
OBJECT-TYPE    
  SEQUENCE OF  
    SdhS2Entry

sdhS2Entry 1.3.6.1.4.1.251.1.1.16.4.1
OBJECT-TYPE    
  SdhS2Entry  

sdhS2LinkNo 1.3.6.1.4.1.251.1.1.16.4.1.1
The link number for this status.
OBJECT-TYPE    
  INTEGER 0..1  

sdhSSectBIP8 1.3.6.1.4.1.251.1.1.16.4.1.2
Section BIP-8 error count.
OBJECT-TYPE    
  Counter  

sdhSSectES 1.3.6.1.4.1.251.1.1.16.4.1.3
Section Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSSectSES 1.3.6.1.4.1.251.1.1.16.4.1.4
Section Severely Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSLineBIP24 1.3.6.1.4.1.251.1.1.16.4.1.5
Line BIP-24 error count.
OBJECT-TYPE    
  Counter  

sdhSLineES 1.3.6.1.4.1.251.1.1.16.4.1.6
Line Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSLineSES 1.3.6.1.4.1.251.1.1.16.4.1.7
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSLineUAS 1.3.6.1.4.1.251.1.1.16.4.1.8
Line Unavailable Seconds
OBJECT-TYPE    
  Counter  

sdhSLineFC 1.3.6.1.4.1.251.1.1.16.4.1.9
Line Failure Count
OBJECT-TYPE    
  Counter  

sdhSPathBIP8 1.3.6.1.4.1.251.1.1.16.4.1.10
The path BIP-8 count.
OBJECT-TYPE    
  Counter  

sdhSPathES 1.3.6.1.4.1.251.1.1.16.4.1.11
Path Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSPathSES 1.3.6.1.4.1.251.1.1.16.4.1.12
Path Severely Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSPathUAS 1.3.6.1.4.1.251.1.1.16.4.1.13
Path Unavailable Seconds
OBJECT-TYPE    
  Counter  

sdhSPathFC 1.3.6.1.4.1.251.1.1.16.4.1.14
Path Failure Count
OBJECT-TYPE    
  Counter  

sdhSLineFEBE 1.3.6.1.4.1.251.1.1.16.4.1.15
Far end block errors.
OBJECT-TYPE    
  Counter  

sdhSLineFarEndES 1.3.6.1.4.1.251.1.1.16.4.1.16
Far End Line Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSLineFarEndSES 1.3.6.1.4.1.251.1.1.16.4.1.17
Far End Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSLineFarEndUAS 1.3.6.1.4.1.251.1.1.16.4.1.18
Far End Line Unavailable Seconds
OBJECT-TYPE    
  Counter  

sdhSLineFarEndFC 1.3.6.1.4.1.251.1.1.16.4.1.19
Far End Line Failure Count
OBJECT-TYPE    
  Counter  

sdhSPathFEBE 1.3.6.1.4.1.251.1.1.16.4.1.20
The Path Far End Block Error count.
OBJECT-TYPE    
  Counter  

sdhSPathFarEndES 1.3.6.1.4.1.251.1.1.16.4.1.21
Far End Path Errored Second
OBJECT-TYPE    
  Counter  

sdhSPathFarEndSES 1.3.6.1.4.1.251.1.1.16.4.1.22
Far End Path Severely Errored Seconds
OBJECT-TYPE    
  Counter  

sdhSPathFarEndUAS 1.3.6.1.4.1.251.1.1.16.4.1.23
Far End Path Unavailable Seconds
OBJECT-TYPE    
  Counter  

sdhSPathFarEndFC 1.3.6.1.4.1.251.1.1.16.4.1.24
Far End Path Failure Count
OBJECT-TYPE    
  Counter  

dv2Pvc 1.3.6.1.4.1.251.1.1.17
OBJECT IDENTIFIER    

pvcResourceTable 1.3.6.1.4.1.251.1.1.17.1
This table contains information about the resource available for pvcs on each link.
OBJECT-TYPE    
  SEQUENCE OF  
    PvcResourceEntry

pvcResourceEntry 1.3.6.1.4.1.251.1.1.17.1.1
OBJECT-TYPE    
  PvcResourceEntry  

pvcSlot 1.3.6.1.4.1.251.1.1.17.1.1.1
The slot number.
OBJECT-TYPE    
  INTEGER 0..15  


pvcVciStart 1.3.6.1.4.1.251.1.1.17.1.1.3
Identifies the start of the range of PVC VCI values supported on this link.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

pvcVciEnd 1.3.6.1.4.1.251.1.1.17.1.1.4
Identifies the end of the range of PVC VCI values supported on this link.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

pvcVpiStart 1.3.6.1.4.1.251.1.1.17.1.1.5
Identifies the start of the range of PVC VPI values supported on this link.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcVpiEnd 1.3.6.1.4.1.251.1.1.17.1.1.6
Identifies the end of the range of PVC VPI values supported on this link.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcVpStart 1.3.6.1.4.1.251.1.1.17.1.1.7
Identifies the start of the range of VPs supported on this link.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcVpEnd 1.3.6.1.4.1.251.1.1.17.1.1.8
Identifies the end of the range of VPs supported on this link.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcBackwardCellRateTotal 1.3.6.1.4.1.251.1.1.17.1.1.11
The backward total cell rate configured for PVCs on this link. Note that this object is in cells per second (CPS).
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcLinkQoS 1.3.6.1.4.1.251.1.1.17.1.1.13
This specifies the type of ATM link.
OBJECT-TYPE    
  INTEGER uni(1), nni(2), b-ici(3), non-atm-link(4)  

pvcMolnVpi 1.3.6.1.4.1.251.1.1.17.1.1.14
This is the VPI for the management overlay network.
OBJECT-TYPE    
  INTEGER 0..255  

pvcMolnVci 1.3.6.1.4.1.251.1.1.17.1.1.15
This is the VCI for the management overlay network.
OBJECT-TYPE    
  INTEGER 0..255  

pvcLowPriOverbookFactor 1.3.6.1.4.1.251.1.1.17.1.1.16
This is the percentage of low priority traffic overbook factor.
OBJECT-TYPE    
  INTEGER 0..10000  

pvcTable 1.3.6.1.4.1.251.1.1.17.2
This table contains information on each PVC.
OBJECT-TYPE    
  SEQUENCE OF  
    PvcEntry

pvcEntry 1.3.6.1.4.1.251.1.1.17.2.1
OBJECT-TYPE    
  PvcEntry  

pvcDSlot 1.3.6.1.4.1.251.1.1.17.2.1.1
The destination slot for the PVC.
OBJECT-TYPE    
  INTEGER 0..15  


pvcDvci 1.3.6.1.4.1.251.1.1.17.2.1.3
The destination virtual circuit identifier for the PVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

pvcDvpi 1.3.6.1.4.1.251.1.1.17.2.1.4
The destination virtual path identifier for the PVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcSSlot 1.3.6.1.4.1.251.1.1.17.2.1.5
The source slot for the PVC.
OBJECT-TYPE    
  INTEGER 0..15  


pvcSvci 1.3.6.1.4.1.251.1.1.17.2.1.7
The source virtual circuit identifier for the PVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

pvcSvpi 1.3.6.1.4.1.251.1.1.17.2.1.8
The source virtual path identifier for the PVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

pvcForwardPeakCellRate 1.3.6.1.4.1.251.1.1.17.2.1.9
Forward Peak Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcForwardPeakSize 1.3.6.1.4.1.251.1.1.17.2.1.10
Forward Peak Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcForwardPeakMode 1.3.6.1.4.1.251.1.1.17.2.1.11
Forward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4)  

pvcBackwardPeakCellRate 1.3.6.1.4.1.251.1.1.17.2.1.12
Backward Peak Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcBackwardPeakSize 1.3.6.1.4.1.251.1.1.17.2.1.13
Backward Peak Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcBackwardPeakMode 1.3.6.1.4.1.251.1.1.17.2.1.14
Backward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4)  

pvcForwardSustainedCellRate 1.3.6.1.4.1.251.1.1.17.2.1.15
Forward Sustained Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcForwardSustainedSize 1.3.6.1.4.1.251.1.1.17.2.1.16
Forward Sustained Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcForwardSustainedMode 1.3.6.1.4.1.251.1.1.17.2.1.17
Forward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4), clp0-tag(6), clp01-tag(8)  

pvcBackwardSustainedCellRate 1.3.6.1.4.1.251.1.1.17.2.1.18
Backward Sustained Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcBackwardSustainedSize 1.3.6.1.4.1.251.1.1.17.2.1.19
Backward Sustained Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcBackwardSustainedMode 1.3.6.1.4.1.251.1.1.17.2.1.20
Backward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4), clp0-tag(6), clp01-tag(8)  

pvcAuxForwardPeakCellRate 1.3.6.1.4.1.251.1.1.17.2.1.21
Auxiliary Forward Peak Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxForwardPeakSize 1.3.6.1.4.1.251.1.1.17.2.1.22
Auxiliary Forward Peak Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxForwardPeakMode 1.3.6.1.4.1.251.1.1.17.2.1.23
Auxiliary Forward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4)  

pvcAuxBackwardPeakCellRate 1.3.6.1.4.1.251.1.1.17.2.1.24
Auxiliary Backward Peak Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxBackwardPeakSize 1.3.6.1.4.1.251.1.1.17.2.1.25
Auxiliary Backward Peak Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxBackwardPeakMode 1.3.6.1.4.1.251.1.1.17.2.1.26
Auxiliary Backward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4)  

pvcAuxForwardSustainedCellRate 1.3.6.1.4.1.251.1.1.17.2.1.27
Auxiliary Forward Sustained Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxForwardSustainedSize 1.3.6.1.4.1.251.1.1.17.2.1.28
Auxiliary Forward Sustained Bucket Size (Cells)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxForwardSustainedMode 1.3.6.1.4.1.251.1.1.17.2.1.29
Auxiliary Forward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4), clp0-tag(6), clp01-tag(8)  

pvcAuxBackwardSustainedCellRate 1.3.6.1.4.1.251.1.1.17.2.1.30
Auxiliary Backward Sustained Cell Rate (CPS)
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxBackwardSustainedSize 1.3.6.1.4.1.251.1.1.17.2.1.31
Auxiliary Backward Sustained Bucket Size
OBJECT-TYPE    
  INTEGER 0..16777215  

pvcAuxBackwardSustainedMode 1.3.6.1.4.1.251.1.1.17.2.1.32
Auxiliary Backward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-disc(2), clp1-disc(3), clp01-disc(4), clp0-tag(6), clp01-tag(8)  

pvcQoSClass 1.3.6.1.4.1.251.1.1.17.2.1.33
CBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) is a `best effort' service - low priority and the cells may be discard.
OBJECT-TYPE    
  INTEGER cbr(1), vbr-high(2), vbr-med(3), vbr-low(4)  

pvcStatus 1.3.6.1.4.1.251.1.1.17.2.1.34
If this object is set to invalid(2), the PVC entry is removed. Set to start-PVC(3) to activate the PVC. When the state changes to running(5) then the PVC is successfully running. (6) pvc restarted
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), start-PVC(3), notified(4), running(5), waiting(6)  

pvcMulticast 1.3.6.1.4.1.251.1.1.17.2.1.35
If this object is set to no, multicast is not allowed; otherwise, multicast is allowed.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pvcInternalVpi 1.3.6.1.4.1.251.1.1.17.2.1.36
This object indicates the internal VPI value that the source side of multicast tree ranslates its orignal VPI to.
OBJECT-TYPE    
  INTEGER  

pvcInternalVci 1.3.6.1.4.1.251.1.1.17.2.1.37
This object indicates the internal VCI value that the source side of multicast tree ranslates its orignal VCI to.
OBJECT-TYPE    
  INTEGER  

pvcNumLeaves 1.3.6.1.4.1.251.1.1.17.2.1.38
This object indicates the number of leaves this multicast tree currently contains.
OBJECT-TYPE    
  INTEGER  

pvcDirection 1.3.6.1.4.1.251.1.1.17.2.1.39
This object determines if a multicast PVC is to be unidirectional or bidirectional
OBJECT-TYPE    
  INTEGER bidirect(1), unidirect(2)  

dv2Svc 1.3.6.1.4.1.251.1.1.18
OBJECT IDENTIFIER    

svcMaxPtPtConnections 1.3.6.1.4.1.251.1.1.18.1
The maximum number of point-to-point connections.
OBJECT-TYPE    
  INTEGER 0..750  

svcMaxPtMptConnections 1.3.6.1.4.1.251.1.1.18.2
The maximum number of point-to-multipoint connections.
OBJECT-TYPE    
  INTEGER 0..25  

svcMaxPtMptParties 1.3.6.1.4.1.251.1.1.18.3
The maximum number of parties in a point-to-multipoint connection.
OBJECT-TYPE    
  INTEGER 0..500  

svcResourceTable 1.3.6.1.4.1.251.1.1.18.6
This table contains information about the resource available for svcs on each link.
OBJECT-TYPE    
  SEQUENCE OF  
    SvcResourceEntry

svcResourceEntry 1.3.6.1.4.1.251.1.1.18.6.1
OBJECT-TYPE    
  SvcResourceEntry  

svcSAP 1.3.6.1.4.1.251.1.1.18.6.1.1
Identifies the SAP.
OBJECT-TYPE    
  INTEGER 0..31  

svcHiLo 1.3.6.1.4.1.251.1.1.18.6.1.2
Select VPI/VCI values from low to high or high to low
OBJECT-TYPE    
  INTEGER low(2), high(1)  

svcVciStart 1.3.6.1.4.1.251.1.1.18.6.1.3
Identifies the start of the range of SVC VCI values supported on this link.
OBJECT-TYPE    
  INTEGER 32..4095  

svcVciEnd 1.3.6.1.4.1.251.1.1.18.6.1.4
Identifies the end of the range of SVC VCI values supported on this link.
OBJECT-TYPE    
  INTEGER 32..4095  

svcVpiStart 1.3.6.1.4.1.251.1.1.18.6.1.5
Identifies the start of the range of SVC VPI values supported on this link.
OBJECT-TYPE    
  INTEGER 0..255  

svcVpiEnd 1.3.6.1.4.1.251.1.1.18.6.1.6
Identifies the end of the range of SVC VPI values supported on this link.
OBJECT-TYPE    
  INTEGER 0..255  

svcVpStart 1.3.6.1.4.1.251.1.1.18.6.1.7
Identifies the start of the range of SVPs supported on this link.
OBJECT-TYPE    
  INTEGER 0..255  

svcVpEnd 1.3.6.1.4.1.251.1.1.18.6.1.8
Identifies the end of the range of SVPs supported on this link.
OBJECT-TYPE    
  INTEGER 0..255  

svcBackwardCellRateTotal 1.3.6.1.4.1.251.1.1.18.6.1.11
The backward total cell rate configured for SVCs on this link. Note that this object is in cells per second (CPS).
OBJECT-TYPE    
  INTEGER 0..16777215  

svcBackwardCellRateAvailable 1.3.6.1.4.1.251.1.1.18.6.1.12
The backward cell rate available for SVCs on this link. Note that this object is in cells per second (CPS).
OBJECT-TYPE    
  INTEGER 0..16777215  

svcSigVci 1.3.6.1.4.1.251.1.1.18.6.1.13
The VCI used for signalling.
OBJECT-TYPE    
  INTEGER 0..511  

svcSigVpi 1.3.6.1.4.1.251.1.1.18.6.1.14
The VPI used for signalling.
OBJECT-TYPE    
  INTEGER 0..255  

svcSAPStatus 1.3.6.1.4.1.251.1.1.18.6.1.15
Select on(4) to activate the SAP, off(1) to deactivate, reconfigure(2) to hot reconfigure the vci/vpi ranges and reset(3) to clear all calls on the SAP.
OBJECT-TYPE    
  INTEGER off(1), reconfigure(2), reset(3), on(4), idle(5)  

svcCDVTSize 1.3.6.1.4.1.251.1.1.18.6.1.16
Cell Delay Variation Tolerance size.
OBJECT-TYPE    
  INTEGER  

svcIntType 1.3.6.1.4.1.251.1.1.18.6.1.17
Interface type - NETWORK or USER.
OBJECT-TYPE    
  INTEGER network(1), user(2)  

svcPolicing 1.3.6.1.4.1.251.1.1.18.6.1.18
Policing - ON or OFF
OBJECT-TYPE    
  INTEGER on(1), off(2)  

svcLowPriOverbookFactor 1.3.6.1.4.1.251.1.1.18.6.1.19
This is the percentage of low priority traffic overbook factor.
OBJECT-TYPE    
  INTEGER 0..10000  

svcMaxSapConn 1.3.6.1.4.1.251.1.1.18.6.1.20
Maximum SVCs this SAP
OBJECT-TYPE    
  INTEGER 0..750  

svcCurSapConn 1.3.6.1.4.1.251.1.1.18.6.1.21
Current SVC count this SAP
OBJECT-TYPE    
  INTEGER  

svcLinkNo 1.3.6.1.4.1.251.1.1.18.6.1.22
This is the physical link number associated with this SAP
OBJECT-TYPE    
  INTEGER 0..3  

svcVpiMapping 1.3.6.1.4.1.251.1.1.18.6.1.23
VPI and VPCI mapping status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

svcQosRoute 1.3.6.1.4.1.251.1.1.18.6.1.24
QoS based route
OBJECT-TYPE    
  INTEGER off(1), on(2)  

svcSwtch 1.3.6.1.4.1.251.1.1.18.6.1.25
UNI Interface Type
OBJECT-TYPE    
  INTEGER uni30(1), uni31(2), iisp30(3), iisp31(4)  

svcRestart 1.3.6.1.4.1.251.1.1.18.6.1.26
Send Restart when link is up
OBJECT-TYPE    
  INTEGER off(1), on(2)  

svcE164Addr 1.3.6.1.4.1.251.1.1.18.6.1.27
The E.164 address for this SAP
OBJECT-TYPE    
  E164  

svcAutoSapOff 1.3.6.1.4.1.251.1.1.18.6.1.28
This option allows a Sap Status to be automatically turned OFF after T309 expiry. Select Yes(1) if a sap (which was ON before) is to be turned OFF after T309 expiry, else select No(2). By default, No(2) is selected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

svcTable 1.3.6.1.4.1.251.1.1.18.7
This table contains information on each on SVC.
OBJECT-TYPE    
  SEQUENCE OF  
    SvcEntry

svcEntry 1.3.6.1.4.1.251.1.1.18.7.1
OBJECT-TYPE    
  SvcEntry  

svcId 1.3.6.1.4.1.251.1.1.18.7.1.1
The svc ID number
OBJECT-TYPE    
  INTEGER 0..2147483647  

svcDSlot 1.3.6.1.4.1.251.1.1.18.7.1.2
The destination slot of the SVC.
OBJECT-TYPE    
  INTEGER 0..15  


svcDvci 1.3.6.1.4.1.251.1.1.18.7.1.4
The destination virtual circuit identifier for the SVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

svcDvpi 1.3.6.1.4.1.251.1.1.18.7.1.5
The destination virtual path identifier for the SVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

svcDE164 1.3.6.1.4.1.251.1.1.18.7.1.6
The destination E.164 address for the SVC.
OBJECT-TYPE    
  E164  

svcDE164Sub 1.3.6.1.4.1.251.1.1.18.7.1.7
The destination sub-address for the SVC.
OBJECT-TYPE    
  E164SUB  

svcSSlot 1.3.6.1.4.1.251.1.1.18.7.1.8
The source slot of the SVC.
OBJECT-TYPE    
  INTEGER 0..15  


svcSvci 1.3.6.1.4.1.251.1.1.18.7.1.10
The source virtual circuit identifier for a SVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

svcSvpi 1.3.6.1.4.1.251.1.1.18.7.1.11
The source virtual path identifier for a SVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

svcSE164 1.3.6.1.4.1.251.1.1.18.7.1.12
The source E.164 address for the SVC.
OBJECT-TYPE    
  E164  

svcSE164Sub 1.3.6.1.4.1.251.1.1.18.7.1.13
The source sub-address for the SVC.
OBJECT-TYPE    
  E164SUB  

svcForwardPeakCellRate 1.3.6.1.4.1.251.1.1.18.7.1.14
The forward user cell rate for a SVC. The forward user cell rate is a measurement of bandwidth available to the initiating user to transfer information to the responding user.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcForwardPeakMode 1.3.6.1.4.1.251.1.1.18.7.1.15
SVC/SVP Forward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6), clp01-tag(8)  

svcBackwardPeakCellRate 1.3.6.1.4.1.251.1.1.18.7.1.16
The backward user cell rate for a SVC. The backward user cell rate is a measurement of bandwidth available to the responding user to transfer information to the initiating user.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcBackwardPeakMode 1.3.6.1.4.1.251.1.1.18.7.1.17
SVC/SVP Backward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6), clp01-tag(8)  

svcForwardSustainableCellRate 1.3.6.1.4.1.251.1.1.18.7.1.18
The sustainable forward cell rate for the SVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcForwardMaxBurstSize 1.3.6.1.4.1.251.1.1.18.7.1.19
The forward maximum burst size for the SVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcForwardSustainableMode 1.3.6.1.4.1.251.1.1.18.7.1.20
SVC/SVP Forward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6), clp01-tag(8)  

svcBackwardSustainableCellRate 1.3.6.1.4.1.251.1.1.18.7.1.21
The sustainable backward cell rate for the SVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcBackwardMaxBurstSize 1.3.6.1.4.1.251.1.1.18.7.1.22
The backward maximum burst size for the SVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcBackwardSustainableMode 1.3.6.1.4.1.251.1.1.18.7.1.23
SVC/SVP Backward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6), clp01-tag(8)  

svcQoSClass 1.3.6.1.4.1.251.1.1.18.7.1.24
CBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) is a `best effort' service - low priority and the cells may be discarded.
OBJECT-TYPE    
  INTEGER qos1(1), qos2(2), qos3(3), qos4(4), ubrBe(5), abr(6), cbr(7), vbrRt(8), vbrNrt(9)  

svcBillTag 1.3.6.1.4.1.251.1.1.18.7.1.25
This identifies the billable SVC.
OBJECT-TYPE    
  INTEGER  

svcDuration 1.3.6.1.4.1.251.1.1.18.7.1.26
Duration of the SVC in milliseconds.
OBJECT-TYPE    
  Counter  

svcType 1.3.6.1.4.1.251.1.1.18.7.1.27
The type of SVC.
OBJECT-TYPE    
  INTEGER point-to-point(1), point-to-multipoint(2)  

svcStatus 1.3.6.1.4.1.251.1.1.18.7.1.28
If this object is set to invalid (2), the SVC is cleared and the entry is removed. If set to active(4) then the SVC is active.
OBJECT-TYPE    
  INTEGER idle(1), invalid(2), reset(3), active(5)  

svcNumLeaves 1.3.6.1.4.1.251.1.1.18.7.1.29
Number of multicast leaves
OBJECT-TYPE    
  INTEGER  

svcInternalVpi 1.3.6.1.4.1.251.1.1.18.7.1.30
internal VPI used for multicast operation
OBJECT-TYPE    
  INTEGER  

svcInternalVci 1.3.6.1.4.1.251.1.1.18.7.1.31
internal VCI used for multicast operation
OBJECT-TYPE    
  INTEGER  

sPvcTable 1.3.6.1.4.1.251.1.1.18.8
This table contains information on Semi-Permanent Virtual Circuits (SPVCs).
OBJECT-TYPE    
  SEQUENCE OF  
    SPvcEntry

sPvcEntry 1.3.6.1.4.1.251.1.1.18.8.1
OBJECT-TYPE    
  SPvcEntry  

sPvcId 1.3.6.1.4.1.251.1.1.18.8.1.1
Slot-unique SPVC identifier.
OBJECT-TYPE    
  INTEGER 1..750  

sPvcCallId 1.3.6.1.4.1.251.1.1.18.8.1.2
Call identifier.
OBJECT-TYPE    
  INTEGER  


sPvcAddress 1.3.6.1.4.1.251.1.1.18.8.1.4
The E.164 address for the SPVC.
OBJECT-TYPE    
  E164  

sPvcForwardPeakCellRate 1.3.6.1.4.1.251.1.1.18.8.1.5
The forward user cell rate for an SPVC. The forward user cell rate is a measurement of bandwidth available to the initiating user to transfer information to the responding user.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcForwardPeakMode 1.3.6.1.4.1.251.1.1.18.8.1.6
SPVC/SPVP Forward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp01-discard(4)  

sPvcBackwardPeakCellRate 1.3.6.1.4.1.251.1.1.18.8.1.7
The backward user cell rate for an SPVC. The backward user cell rate is a measurement of bandwidth available to the responding user to transfer information to the initiating user.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcBackwardPeakMode 1.3.6.1.4.1.251.1.1.18.8.1.8
SPVC/SPVP Backward Peak Mode
OBJECT-TYPE    
  INTEGER off(1), clp01-discard(4)  

sPvcForwardSustainableCellRate 1.3.6.1.4.1.251.1.1.18.8.1.9
The sustainable forward cell rate for the SPVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcForwardMaxBurstSize 1.3.6.1.4.1.251.1.1.18.8.1.10
The forward maximum burst size for the SPVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcForwardSustainableMode 1.3.6.1.4.1.251.1.1.18.8.1.11
SPVC/SPVP Forward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6)  

sPvcBackwardSustainableCellRate 1.3.6.1.4.1.251.1.1.18.8.1.12
The sustainable backward cell rate for the SPVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcBackwardMaxBurstSize 1.3.6.1.4.1.251.1.1.18.8.1.13
The backward maximum burst size for the SPVC.
OBJECT-TYPE    
  INTEGER 0..16777215  

sPvcBackwardSustainableMode 1.3.6.1.4.1.251.1.1.18.8.1.14
SPVC/SPVP Backward Sustained Mode
OBJECT-TYPE    
  INTEGER off(1), clp0-discard(2), clp01-discard(4), clp0-tag(6)  

sPvcQoSClass 1.3.6.1.4.1.251.1.1.18.8.1.15
CBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) has low priority and the cells may be discarded, best-effort is the same as vbr-low except no bandwidth is reserved.
OBJECT-TYPE    
  INTEGER cbr(1), vbr-high(2), vbr-med(3), vbr-low(4), best-effort(5)  

sPvcSourceVci 1.3.6.1.4.1.251.1.1.18.8.1.16
The source virtual circuit identifier for the SPVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

sPvcSourceVpi 1.3.6.1.4.1.251.1.1.18.8.1.17
The source virtual path identifier for the SPVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

sPvcTargetVci 1.3.6.1.4.1.251.1.1.18.8.1.18
The target virtual circuit identifier for the SPVC.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

sPvcTargetVpi 1.3.6.1.4.1.251.1.1.18.8.1.19
The target virtual path identifier for the SPVC.
OBJECT-TYPE    
  VirtualPathIdentifier  

sPvcRetry 1.3.6.1.4.1.251.1.1.18.8.1.20
Retry timeout. Zero represents an infinite timeout.
OBJECT-TYPE    
  INTEGER 0..1000  

sPvcConnectTime 1.3.6.1.4.1.251.1.1.18.8.1.21
Connect time in ms.
OBJECT-TYPE    
  INTEGER  

sPvcNumberRetries 1.3.6.1.4.1.251.1.1.18.8.1.22
Number of retries to attempt. Zero represents no limit.
OBJECT-TYPE    
  INTEGER 0..1000  

sPvcFailures 1.3.6.1.4.1.251.1.1.18.8.1.23
A count of the SPVC setup failures.
OBJECT-TYPE    
  INTEGER  

sPvcAlertFailures 1.3.6.1.4.1.251.1.1.18.8.1.24
Describes the circumstances under which to issue an Alert message to the NMS.
OBJECT-TYPE    
  INTEGER no-trap(1), fail(2), fail-or-clear(3), fail-all-attempts(4), call-success(5), trap-all(6), trap-state-change(7)  

sPvcCauseDiag 1.3.6.1.4.1.251.1.1.18.8.1.25
Cause and diagnostic codes.
OBJECT-TYPE    
  Q93bCauseDiag  

sPvcType 1.3.6.1.4.1.251.1.1.18.8.1.26
If the SPVC entry is passive, it will not try to initiate a call. An active will attempt to build an SPVC at intervals set by the retry field.
OBJECT-TYPE    
  INTEGER passive(1), active(2)  

sPvcCallState 1.3.6.1.4.1.251.1.1.18.8.1.27
Sets the state of the SPVC. Set the value to invalid(3) to tear down the SPVC.
OBJECT-TYPE    
  INTEGER idle(1), call-setup(2), reset(3), invalid(4)  

sPvcStatus 1.3.6.1.4.1.251.1.1.18.8.1.28
Describes the state of the SPVC.
OBJECT-TYPE    
  INTEGER idle(1), sPVC-wait(2), l4-wait(3), active(4)  

sPvcCauseDiagCode 1.3.6.1.4.1.251.1.1.18.8.1.29
Cause and diagnostic codes as defined in UNI-3.0 Annex E .
OBJECT-TYPE    
  INTEGER  

sPvcMulticast 1.3.6.1.4.1.251.1.1.18.8.1.30
pt-pt - point-to-point SPVC; pt-mpt - point-to-multipoint SPVC; bidirect-root: pt-mpt birection root.
OBJECT-TYPE    
  INTEGER pt-pt(1), pt-mpt-root(2), pt-mpt-leaf(3), bidirect-root(4)  

svcQ93bStatTable 1.3.6.1.4.1.251.1.1.18.9
This table contains statistical protocol information for each link.
OBJECT-TYPE    
  SEQUENCE OF  
    SvcQ93bStatEntry

svcQ93bStatEntry 1.3.6.1.4.1.251.1.1.18.9.1
OBJECT-TYPE    
  SvcQ93bStatEntry  

svcQ93bStatSAP 1.3.6.1.4.1.251.1.1.18.9.1.1
This is the layer 3 Service Access Point for the link.
OBJECT-TYPE    
  INTEGER 0..31  

svcQ93bStatActive 1.3.6.1.4.1.251.1.1.18.9.1.2
Number of calls currently active on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAccumalative 1.3.6.1.4.1.251.1.1.18.9.1.3
Total number of calls established on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatCallProcTx 1.3.6.1.4.1.251.1.1.18.9.1.4
Call Proceeding pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatConnTx 1.3.6.1.4.1.251.1.1.18.9.1.5
Connect pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatConnAckTx 1.3.6.1.4.1.251.1.1.18.9.1.6
Connect Acknowledge pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatSetupTx 1.3.6.1.4.1.251.1.1.18.9.1.7
Setup pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRelTx 1.3.6.1.4.1.251.1.1.18.9.1.8
Release pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRelCmpltTx 1.3.6.1.4.1.251.1.1.18.9.1.9
Release Complete pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRstTx 1.3.6.1.4.1.251.1.1.18.9.1.10
Restart pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRstAckTx 1.3.6.1.4.1.251.1.1.18.9.1.11
Restart Acknowledge pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatStatTx 1.3.6.1.4.1.251.1.1.18.9.1.12
Status pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatStatEnqTx 1.3.6.1.4.1.251.1.1.18.9.1.13
Status Enquiry pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyTx 1.3.6.1.4.1.251.1.1.18.9.1.14
Add Party pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyAckTx 1.3.6.1.4.1.251.1.1.18.9.1.15
Add Party Acknowledge pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyRejTx 1.3.6.1.4.1.251.1.1.18.9.1.16
Add Party Reject pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatDropPtyTx 1.3.6.1.4.1.251.1.1.18.9.1.17
Drop Party pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatDropPtyAckTx 1.3.6.1.4.1.251.1.1.18.9.1.18
Drop Party Acknowledge pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatLstCauseTx 1.3.6.1.4.1.251.1.1.18.9.1.19
Last cause code transmitted.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatLstDiagTx 1.3.6.1.4.1.251.1.1.18.9.1.20
Last diagnostic code transmitted.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatCallProcRx 1.3.6.1.4.1.251.1.1.18.9.1.21
Call Proceeding pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatConnRx 1.3.6.1.4.1.251.1.1.18.9.1.22
Connect pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatConnAckRx 1.3.6.1.4.1.251.1.1.18.9.1.23
Connect Acknowledge pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatSetupRx 1.3.6.1.4.1.251.1.1.18.9.1.24
Setup pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRelRx 1.3.6.1.4.1.251.1.1.18.9.1.25
Release pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRelCmpltRx 1.3.6.1.4.1.251.1.1.18.9.1.26
Release Complete pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRstRx 1.3.6.1.4.1.251.1.1.18.9.1.27
Restart pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatRstAckRx 1.3.6.1.4.1.251.1.1.18.9.1.28
Restart Acknowledge pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatStatRx 1.3.6.1.4.1.251.1.1.18.9.1.29
Status pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatStatEnqRx 1.3.6.1.4.1.251.1.1.18.9.1.30
Status Enquiry pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyRx 1.3.6.1.4.1.251.1.1.18.9.1.31
Add Party pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyAckRx 1.3.6.1.4.1.251.1.1.18.9.1.32
Add Party Acknowledge pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatAddPtyRejRx 1.3.6.1.4.1.251.1.1.18.9.1.33
Add Party Reject pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatDropPtyRx 1.3.6.1.4.1.251.1.1.18.9.1.34
Drop Party pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatDropPtyAckRx 1.3.6.1.4.1.251.1.1.18.9.1.35
Drop Party Acknowledge pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatLstCauseRx 1.3.6.1.4.1.251.1.1.18.9.1.36
Last cause code received.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatLstDiagRx 1.3.6.1.4.1.251.1.1.18.9.1.37
Last diagnostic code received.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQ93bStatClr 1.3.6.1.4.1.251.1.1.18.9.1.38
Clear Q.93B statistics for this SAP.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

svcQ93bStatDiagTx 1.3.6.1.4.1.251.1.1.18.9.1.39
Tx SAP diagnostic codes
OBJECT-TYPE    
  Q93bCauseDiag  

svcQ93bStatDiagRx 1.3.6.1.4.1.251.1.1.18.9.1.40
Rx SAP diagnostic codes
OBJECT-TYPE    
  Q93bCauseDiag  

svcQsaalStatTable 1.3.6.1.4.1.251.1.1.18.10
This table contains protocol information for the Q.SAAL layer for each link.
OBJECT-TYPE    
  SEQUENCE OF  
    SvcQsaalStatEntry

svcQsaalStatEntry 1.3.6.1.4.1.251.1.1.18.10.1
OBJECT-TYPE    
  SvcQsaalStatEntry  

svcQsaalStatSAP 1.3.6.1.4.1.251.1.1.18.10.1.1
This is the layer 3 Service Access Point for the link.
OBJECT-TYPE    
  INTEGER 0..31  

svcQsaalStatOutSduDisc 1.3.6.1.4.1.251.1.1.18.10.1.2
Outgoing SDUs discarded.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatInPduErr 1.3.6.1.4.1.251.1.1.18.10.1.3
Number of incoming PDUs with a reception error.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatInPduDisc 1.3.6.1.4.1.251.1.1.18.10.1.4
Number of incoming PDUs discarded.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatOutPduErr 1.3.6.1.4.1.251.1.1.18.10.1.5
Number of outgoing PDUs with a transmission error.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatOutPduDisc 1.3.6.1.4.1.251.1.1.18.10.1.6
Number of outgoing PDUs discarded.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgnTx 1.3.6.1.4.1.251.1.1.18.10.1.7
BGN pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgakTx 1.3.6.1.4.1.251.1.1.18.10.1.8
BGAK pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgrejTx 1.3.6.1.4.1.251.1.1.18.10.1.9
BGREJ pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatEndTx 1.3.6.1.4.1.251.1.1.18.10.1.10
END pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatRsTx 1.3.6.1.4.1.251.1.1.18.10.1.11
RS pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatRsakTx 1.3.6.1.4.1.251.1.1.18.10.1.12
RSAK pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatSdTx 1.3.6.1.4.1.251.1.1.18.10.1.13
SD pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatSdpTx 1.3.6.1.4.1.251.1.1.18.10.1.14
SDP pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatPollTx 1.3.6.1.4.1.251.1.1.18.10.1.15
POLL pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatStatTx 1.3.6.1.4.1.251.1.1.18.10.1.16
STAT pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatUstatTx 1.3.6.1.4.1.251.1.1.18.10.1.17
USTAT pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatUdTx 1.3.6.1.4.1.251.1.1.18.10.1.18
UD pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatMdTx 1.3.6.1.4.1.251.1.1.18.10.1.19
MD pdus transmitted on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgnRx 1.3.6.1.4.1.251.1.1.18.10.1.20
BGN pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgakRx 1.3.6.1.4.1.251.1.1.18.10.1.21
BGAK pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatBgrejRx 1.3.6.1.4.1.251.1.1.18.10.1.22
BGREJ pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatEndRx 1.3.6.1.4.1.251.1.1.18.10.1.23
END pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatRsRx 1.3.6.1.4.1.251.1.1.18.10.1.24
RS pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatRsakRx 1.3.6.1.4.1.251.1.1.18.10.1.25
RSAK pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatSdRx 1.3.6.1.4.1.251.1.1.18.10.1.26
SD pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatSdpRx 1.3.6.1.4.1.251.1.1.18.10.1.27
SDP pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatPollRx 1.3.6.1.4.1.251.1.1.18.10.1.28
POLL pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatStatRx 1.3.6.1.4.1.251.1.1.18.10.1.29
STAT pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatUstatRx 1.3.6.1.4.1.251.1.1.18.10.1.30
USTAT pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatUdRx 1.3.6.1.4.1.251.1.1.18.10.1.31
UD pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatMdRx 1.3.6.1.4.1.251.1.1.18.10.1.32
MD pdus received on this SAP.
OBJECT-TYPE    
  INTEGER 0..16777215  

svcQsaalStatClr 1.3.6.1.4.1.251.1.1.18.10.1.33
Clear statistics for this SAP.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

svcQsaalTmrPoll 1.3.6.1.4.1.251.1.1.18.11
SSCOP Timer_POLL (8=800ms).
OBJECT-TYPE    
  INTEGER  

svcQsaalTmrKeepAlive 1.3.6.1.4.1.251.1.1.18.12
SSCOP Timer_KEEPALIVE (20=2seconds).
OBJECT-TYPE    
  INTEGER  

svcQsaalTmrNoResponse 1.3.6.1.4.1.251.1.1.18.13
SSCOP Timer_NORESPONSE (100=10seconds).
OBJECT-TYPE    
  INTEGER  

svcQsaalTmrCC 1.3.6.1.4.1.251.1.1.18.14
SSCOP Timer_CC (20=2seconds).
OBJECT-TYPE    
  INTEGER  

svcQsaalMaxPD 1.3.6.1.4.1.251.1.1.18.15
SSCOP Maximum PD.
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT303 1.3.6.1.4.1.251.1.1.18.16
Q.93B T303 (40=4seconds).
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT310 1.3.6.1.4.1.251.1.1.18.17
Q.93B T310 (200=20seconds).
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT308 1.3.6.1.4.1.251.1.1.18.18
Q.93B T308 (300=30seconds).
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT309 1.3.6.1.4.1.251.1.1.18.19
Q.93B T309 (150=15seconds).
OBJECT-TYPE    
  INTEGER  

maxOutstanding 1.3.6.1.4.1.251.1.1.18.20
Max Outgoing Outstanding Calls.
OBJECT-TYPE    
  INTEGER 1..20  

svcLoadRoute 1.3.6.1.4.1.251.1.1.18.21
Poke point for loading routing tables
OBJECT-TYPE    
  INTEGER both(1), none(2), rte-table(3), dtl-bin(4)  

svcHalfConTimer 1.3.6.1.4.1.251.1.1.18.22
SVC half connect recovery poll timer
OBJECT-TYPE    
  INTEGER 0..3000  

svcHalfConCnt 1.3.6.1.4.1.251.1.1.18.23
SVC half connect counter
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT398 1.3.6.1.4.1.251.1.1.18.24
Q.93B T398 (40= 4 seconds).
OBJECT-TYPE    
  INTEGER  

svcQ93bTmrT399 1.3.6.1.4.1.251.1.1.18.25
Q.93B T399 (140= 14 seconds).
OBJECT-TYPE    
  INTEGER  

svcRetryPeriod 1.3.6.1.4.1.251.1.1.18.26
Retry Period
OBJECT-TYPE    
  INTEGER 15..180  

svcCellRateTable 1.3.6.1.4.1.251.1.1.18.27
This table contains information about the limitations on Cell Rates on link
OBJECT-TYPE    
  SEQUENCE OF  
    SvcCellRateEntry

svcCellRateEntry 1.3.6.1.4.1.251.1.1.18.27.1
OBJECT-TYPE    
  SvcCellRateEntry  

svcCRLinkNo 1.3.6.1.4.1.251.1.1.18.27.1.1
This is the physical link number associated with this SAP
OBJECT-TYPE    
  INTEGER 0..3  

svcPCRCLP01Max 1.3.6.1.4.1.251.1.1.18.27.1.2
PCRCLP01 Max(0 disables checking)
OBJECT-TYPE    
  INTEGER 0..16777216  

svcSCRMax 1.3.6.1.4.1.251.1.1.18.27.1.3
SCR Max(0 disables checking)
OBJECT-TYPE    
  INTEGER 0..16777216  

svcMBSMax 1.3.6.1.4.1.251.1.1.18.27.1.4
MBS Max(0 disables checking)
OBJECT-TYPE    
  INTEGER 0..16777216  

svcTrafficTable 1.3.6.1.4.1.251.1.1.18.28
This table contains information about the limitations on Cell Rates on link
OBJECT-TYPE    
  SEQUENCE OF  
    SvcTrafficEntry

svcTrafficEntry 1.3.6.1.4.1.251.1.1.18.28.1
OBJECT-TYPE    
  SvcTrafficEntry  

svcTLinkNo 1.3.6.1.4.1.251.1.1.18.28.1.1
Lnk Number
OBJECT-TYPE    
  INTEGER 0..3  

svcCBRallowed 1.3.6.1.4.1.251.1.1.18.28.1.2
Allows or disallows CBR traffic
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

svcVBRHallowed 1.3.6.1.4.1.251.1.1.18.28.1.3
Allows or disallows VBR High traffic
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

svcVBRMallowed 1.3.6.1.4.1.251.1.1.18.28.1.4
Allows or disallows VBR Med traffic
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

svcVBRLUBRallowed 1.3.6.1.4.1.251.1.1.18.28.1.5
Allows or disallows VBR Low/UBR traffic
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

svcVBRLUBRsubtractpercent 1.3.6.1.4.1.251.1.1.18.28.1.6
Specifies a percentage of BW to be subtracted for VBR Low/UBR traffic
OBJECT-TYPE    
  INTEGER 0..100  

dv2CE 1.3.6.1.4.1.251.1.1.19
OBJECT IDENTIFIER    

ceTable 1.3.6.1.4.1.251.1.1.19.1
Configuration Table for dv2CE Links
OBJECT-TYPE    
  SEQUENCE OF  
    CeEntry

ceEntry 1.3.6.1.4.1.251.1.1.19.1.1
OBJECT-TYPE    
  CeEntry  

ceLinkNo 1.3.6.1.4.1.251.1.1.19.1.1.1
Link Number for Table Entry
OBJECT-TYPE    
  INTEGER 0..127  

ceEnable 1.3.6.1.4.1.251.1.1.19.1.1.2
Setting to yes(1) enables the Link
OBJECT-TYPE    
  INTEGER yes(1), no(2), restart(3)  

ceMode 1.3.6.1.4.1.251.1.1.19.1.1.3
Service Clock Recovery Mode
OBJECT-TYPE    
  INTEGER none(1), adaptive(2), srts(3)  

cePriority 1.3.6.1.4.1.251.1.1.19.1.1.4
Set to high for normal CBR operation
OBJECT-TYPE    
  INTEGER high(1), low(2)  

cePvcValid 1.3.6.1.4.1.251.1.1.19.1.1.5
Indicates if valid PVC exists for Link
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceDstSlot 1.3.6.1.4.1.251.1.1.19.1.1.6
Destination Slot for PVC
OBJECT-TYPE    
  INTEGER 0..15  


ceDstVpi 1.3.6.1.4.1.251.1.1.19.1.1.8
Destination VPI for PVC
OBJECT-TYPE    
  VirtualPathIdentifier  

ceDstVci 1.3.6.1.4.1.251.1.1.19.1.1.9
Destination VCI for PVC
OBJECT-TYPE    
  VirtualCircuitIdentifier  

ceCDV 1.3.6.1.4.1.251.1.1.19.1.1.10
Cell Delay Variation Tolerance
OBJECT-TYPE    
  INTEGER 1..31  

ceCDVMax 1.3.6.1.4.1.251.1.1.19.1.1.11
Cell Delay Variation Tolerance
OBJECT-TYPE    
  INTEGER 1..62  

ceMulticast 1.3.6.1.4.1.251.1.1.19.1.1.24
Is link part of multicast tree
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceXhInt 1.3.6.1.4.1.251.1.1.19.1.1.25
XH Interface for Link
OBJECT-TYPE    
  INTEGER inactive(1), point-to-point(2), uni-root(3), bi-root(4), uni-rt-and-leaf(5), uni-leaf(6), bi-leaf(7), unknown(8)  

ceStatTable 1.3.6.1.4.1.251.1.1.19.2
status information about the dv2CE.
OBJECT-TYPE    
  SEQUENCE OF  
    CeStatEntry

ceStatEntry 1.3.6.1.4.1.251.1.1.19.2.1
OBJECT-TYPE    
  CeStatEntry  

ceStatPortNo 1.3.6.1.4.1.251.1.1.19.2.1.1
Link Number for Table Entry
OBJECT-TYPE    
  INTEGER 0..3  

ceStatReset 1.3.6.1.4.1.251.1.1.19.2.1.2
Clear Statistics for Link
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceStatTxState 1.3.6.1.4.1.251.1.1.19.2.1.3
Indicates if data is being received and segmented
OBJECT-TYPE    
  INTEGER idle(1), start(2), fifostart(3), wideband(4), fifokick(5), narrowband(6), operating(7)  

ceStatRxState 1.3.6.1.4.1.251.1.1.19.2.1.4
Indicates if data being reassembled and transmitted
OBJECT-TYPE    
  INTEGER idle(1), ais(2), operating(3)  

ceTxCnt 1.3.6.1.4.1.251.1.1.19.2.1.5
Count of Cells transmitted from switch fabric
OBJECT-TYPE    
  Counter  

ceRxCnt 1.3.6.1.4.1.251.1.1.19.2.1.6
Count of Cells received into switch fabric
OBJECT-TYPE    
  Counter  

ceOflCnt 1.3.6.1.4.1.251.1.1.19.2.1.7
Count of 1S intervals during which RX FIFO overflowed
OBJECT-TYPE    
  Counter  

ceUflCnt 1.3.6.1.4.1.251.1.1.19.2.1.8
Count of 1S intervals during which RX FIFO underflowed
OBJECT-TYPE    
  Counter  

ceDisCnt 1.3.6.1.4.1.251.1.1.19.2.1.9
Count of 1S intervals during which cells were discarded
OBJECT-TYPE    
  Counter  

ceInvCnt 1.3.6.1.4.1.251.1.1.19.2.1.10
Count of 1S intervals during which cells were invented
OBJECT-TYPE    
  Counter  

ceResCnt 1.3.6.1.4.1.251.1.1.19.2.1.11
Count of 1S intervals during which AAL1 resync occurred
OBJECT-TYPE    
  Counter  

ceFifoLvlCnt 1.3.6.1.4.1.251.1.1.19.2.1.12
Number of Cells currently in FIFO
OBJECT-TYPE    
  Counter  

cePriVal 1.3.6.1.4.1.251.1.1.19.21
Primary Clock Valid
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceSecVal 1.3.6.1.4.1.251.1.1.19.22
Secondary Clock Valid
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceClkSel 1.3.6.1.4.1.251.1.1.19.23
Clock Select
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

ceClkInp 1.3.6.1.4.1.251.1.1.19.24
Is there clock input
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ceStr3 1.3.6.1.4.1.251.1.1.19.25
Is there STR3
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dv2VE 1.3.6.1.4.1.251.1.1.20
OBJECT IDENTIFIER    

veTable 1.3.6.1.4.1.251.1.1.20.1
Configuration Table for dv2VE Links
OBJECT-TYPE    
  SEQUENCE OF  
    VeEntry

veEntry 1.3.6.1.4.1.251.1.1.20.1.1
OBJECT-TYPE    
  VeEntry  

veLinkNo 1.3.6.1.4.1.251.1.1.20.1.1.1
Link Number for Table Entry
OBJECT-TYPE    
  INTEGER 0..127  

veEnable 1.3.6.1.4.1.251.1.1.20.1.1.2
Setting to yes(1) enables the Link
OBJECT-TYPE    
  INTEGER yes(1), no(2), restart(3)  

veMode 1.3.6.1.4.1.251.1.1.20.1.1.3
Service Clock Recovery Mode
OBJECT-TYPE    
  INTEGER video(4)  

vePriority 1.3.6.1.4.1.251.1.1.20.1.1.4
Set to high for normal CBR operation
OBJECT-TYPE    
  INTEGER high(1), low(2)  

vePvcValid 1.3.6.1.4.1.251.1.1.20.1.1.5
Indicates if valid PVC exists for Link
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

veDstSlot 1.3.6.1.4.1.251.1.1.20.1.1.6
Destination Slot for PVC
OBJECT-TYPE    
  INTEGER 0..15  


veDstVpi 1.3.6.1.4.1.251.1.1.20.1.1.8
Destination VPI for PVC
OBJECT-TYPE    
  VirtualPathIdentifier  

veDstVci 1.3.6.1.4.1.251.1.1.20.1.1.9
Destination VCI for PVC
OBJECT-TYPE    
  VirtualCircuitIdentifier  

veCDV 1.3.6.1.4.1.251.1.1.20.1.1.10
Cell Delay Variation Tolerance
OBJECT-TYPE    
  INTEGER 1..31  

veCDVMax 1.3.6.1.4.1.251.1.1.20.1.1.11
Cell Delay Variation Tolerance
OBJECT-TYPE    
  INTEGER 1..62  

veMulticast 1.3.6.1.4.1.251.1.1.20.1.1.24
Is link part of multicast tree
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

veXhInt 1.3.6.1.4.1.251.1.1.20.1.1.25
XH Interface for Link
OBJECT-TYPE    
  INTEGER inactive(1), point-to-point(2), uni-root(3), bi-root(4), uni-rt-and-leaf(5), uni-leaf(6), bi-leaf(7), unknown(8)  

veStatTable 1.3.6.1.4.1.251.1.1.20.2
status information about the dv2VE.
OBJECT-TYPE    
  SEQUENCE OF  
    VeStatEntry

veStatEntry 1.3.6.1.4.1.251.1.1.20.2.1
OBJECT-TYPE    
  VeStatEntry  

veStatPortNo 1.3.6.1.4.1.251.1.1.20.2.1.1
Link Number for Table Entry
OBJECT-TYPE    
  INTEGER 0..3  

veStatReset 1.3.6.1.4.1.251.1.1.20.2.1.2
Clear Statistics for Link
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

veStatTxState 1.3.6.1.4.1.251.1.1.20.2.1.3
Indicates if data is being received and segmented
OBJECT-TYPE    
  INTEGER idle(1), start(2), fifostart(3), wideband(4), fifokick(5), narrowband(6), operating(7)  

veStatRxState 1.3.6.1.4.1.251.1.1.20.2.1.4
Indicates if data being reassembled and transmitted
OBJECT-TYPE    
  INTEGER idle(1), ais(2), operating(3)  

veTxCnt 1.3.6.1.4.1.251.1.1.20.2.1.5
Count of Cells transmitted from switch fabric
OBJECT-TYPE    
  Counter  

veRxCnt 1.3.6.1.4.1.251.1.1.20.2.1.6
Count of Cells received into switch fabric
OBJECT-TYPE    
  Counter  

veOflCnt 1.3.6.1.4.1.251.1.1.20.2.1.7
Count of 1S intervals during which RX FIFO overflowed or underflowed
OBJECT-TYPE    
  Counter  

veUflCnt 1.3.6.1.4.1.251.1.1.20.2.1.8
Count of 1S intervals during which RX FIFO underflowed
OBJECT-TYPE    
  Counter  

veDisCnt 1.3.6.1.4.1.251.1.1.20.2.1.9
Count of 1S intervals during which cells were discarded
OBJECT-TYPE    
  Counter  

veInvCnt 1.3.6.1.4.1.251.1.1.20.2.1.10
Count of 1S intervals during which cells were invented
OBJECT-TYPE    
  Counter  

veResCnt 1.3.6.1.4.1.251.1.1.20.2.1.11
Count of 1S intervals during which AAL1 resync occurred
OBJECT-TYPE    
  Counter  

veFifoLvlCnt 1.3.6.1.4.1.251.1.1.20.2.1.12
Number of Cells currently in FIFO
OBJECT-TYPE    
  Counter  

dv2SystemClocks 1.3.6.1.4.1.251.1.1.21
OBJECT IDENTIFIER    

autoRevert 1.3.6.1.4.1.251.1.1.21.1
Automatic Revert after Timing Source Recovery
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

revertTimer 1.3.6.1.4.1.251.1.1.21.2
Revert Timer in Seconds
OBJECT-TYPE    
  INTEGER 5..60  

forceRevert 1.3.6.1.4.1.251.1.1.21.3
Force Immediate Revert
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

forceSecondary 1.3.6.1.4.1.251.1.1.21.4
Force Secondary Source Timing
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

alarmStatus 1.3.6.1.4.1.251.1.1.21.5
Timing Alarm Status
OBJECT-TYPE    
  INTEGER clear(1), minor(2), major(3)  

inService 1.3.6.1.4.1.251.1.1.21.6
Card in Service
OBJECT-TYPE    
  INTEGER none(1), pri-line(2), pri-internal(3), pri-stratum3(4), pri-external(5), sec-line(6), sec-internal(7), sec-stratum3(8), sec-external(9), pri-plcp(10), sec-plcp(11)  

primaryClockTable 1.3.6.1.4.1.251.1.1.21.7
OBJECT-TYPE    
  SEQUENCE OF  
    PrimaryEntry

primaryEntry 1.3.6.1.4.1.251.1.1.21.7.1
OBJECT-TYPE    
  PrimaryEntry  

pIndex 1.3.6.1.4.1.251.1.1.21.7.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pValidSource 1.3.6.1.4.1.251.1.1.21.7.1.2
Valid Timing Source
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pOnOffLine 1.3.6.1.4.1.251.1.1.21.7.1.3
On / Off line Toggle
OBJECT-TYPE    
  INTEGER on(1), off(2)  

pSlotNumber 1.3.6.1.4.1.251.1.1.21.7.1.4
Primary Source Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

pSysRefSelect 1.3.6.1.4.1.251.1.1.21.7.1.5
System Reference Select
OBJECT-TYPE    
  INTEGER link0(1), link1(2), link2(3), link3(4), local-oscillator(5)  

pActiveTimingSource 1.3.6.1.4.1.251.1.1.21.7.1.6
Active Timing Reference
OBJECT-TYPE    
  INTEGER line(1), internal(2), plcp(3)  

pInputLineOk 1.3.6.1.4.1.251.1.1.21.7.1.7
Input Line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pSysRefTimingOk 1.3.6.1.4.1.251.1.1.21.7.1.8
System Reference Timing OK
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

secondaryClockTable 1.3.6.1.4.1.251.1.1.21.8
OBJECT-TYPE    
  SEQUENCE OF  
    SecondaryEntry

secondaryEntry 1.3.6.1.4.1.251.1.1.21.8.1
OBJECT-TYPE    
  SecondaryEntry  

sIndex 1.3.6.1.4.1.251.1.1.21.8.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sValidSource 1.3.6.1.4.1.251.1.1.21.8.1.2
Valid Timing Source
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sOnOffLine 1.3.6.1.4.1.251.1.1.21.8.1.3
On / Off line Toggle
OBJECT-TYPE    
  INTEGER on(1), off(2)  

sSlotNumber 1.3.6.1.4.1.251.1.1.21.8.1.4
Secondary Source Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

sSysRefSelect 1.3.6.1.4.1.251.1.1.21.8.1.5
System Reference Select
OBJECT-TYPE    
  INTEGER link0(1), link1(2), link2(3), link3(4), local-oscillator(5)  

sActiveTimingSource 1.3.6.1.4.1.251.1.1.21.8.1.6
Active Timing Reference
OBJECT-TYPE    
  INTEGER line(1), internal(2), plcp(3)  

sInputLineOk 1.3.6.1.4.1.251.1.1.21.8.1.7
Input Line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sSysRefTimingOk 1.3.6.1.4.1.251.1.1.21.8.1.8
System Reference Timing OK
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

str3Configured 1.3.6.1.4.1.251.1.1.21.9
CAT Card present
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pCATcontrolTable 1.3.6.1.4.1.251.1.1.21.10
OBJECT-TYPE    
  SEQUENCE OF  
    PCATcontrolEntry

pCATcontrolEntry 1.3.6.1.4.1.251.1.1.21.10.1
OBJECT-TYPE    
  PCATcontrolEntry  

pccIndex 1.3.6.1.4.1.251.1.1.21.10.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pccatlimtype 1.3.6.1.4.1.251.1.1.21.10.1.2
Type of CAT LIM
OBJECT-TYPE    
  INTEGER none(1), t1(2), e1(3)  

pccatsendcode 1.3.6.1.4.1.251.1.1.21.10.1.3
Send code to NTM LIM
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pccatactivate 1.3.6.1.4.1.251.1.1.21.10.1.4
Activate NTM Code
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pccatsendconfig 1.3.6.1.4.1.251.1.1.21.10.1.5
Send Configuration to NTM LIM
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pccatbytestransferred 1.3.6.1.4.1.251.1.1.21.10.1.6
Code bytes transferred to NTM LIM
OBJECT-TYPE    
  INTEGER  

pccatfilexferstat 1.3.6.1.4.1.251.1.1.21.10.1.7
File transfer status as reported by Slot 0
OBJECT-TYPE    
  INTEGER idle(1), start(2), continue(3), end(4), ack(5), aborted(6), error(7)  

pcatforcesecext 1.3.6.1.4.1.251.1.1.21.10.1.8
Force the secondary external
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pcatforcesecstr3 1.3.6.1.4.1.251.1.1.21.10.1.9
Force the secondary stratum 3
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pcatcommand 1.3.6.1.4.1.251.1.1.21.10.1.10
Internal Use
OBJECT-TYPE    
  INTEGER none(1), revert(2)  

pcatplaceholder1 1.3.6.1.4.1.251.1.1.21.10.1.11
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

pcatplaceholder2 1.3.6.1.4.1.251.1.1.21.10.1.12
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

pcconoffline 1.3.6.1.4.1.251.1.1.21.10.1.13
Put NTM LIM on or offline
OBJECT-TYPE    
  INTEGER offline(1), online(2)  

sCATcontrolTable 1.3.6.1.4.1.251.1.1.21.11
OBJECT-TYPE    
  SEQUENCE OF  
    SCATcontrolEntry

sCATcontrolEntry 1.3.6.1.4.1.251.1.1.21.11.1
OBJECT-TYPE    
  SCATcontrolEntry  

sccIndex 1.3.6.1.4.1.251.1.1.21.11.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sccatlimtype 1.3.6.1.4.1.251.1.1.21.11.1.2
Type of NTM LIM
OBJECT-TYPE    
  INTEGER none(1), t1(2), e1(3)  

sccatsendcode 1.3.6.1.4.1.251.1.1.21.11.1.3
Download code to NTM LIM
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sccatactivate 1.3.6.1.4.1.251.1.1.21.11.1.4
Activate NTM Code
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sccatsendconfig 1.3.6.1.4.1.251.1.1.21.11.1.5
Download Configuration to NTM LIM
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sccatbytestransferred 1.3.6.1.4.1.251.1.1.21.11.1.6
Code bytes transferred to NTM LIM
OBJECT-TYPE    
  INTEGER  

sccatfilexferstat 1.3.6.1.4.1.251.1.1.21.11.1.7
File transfer status as reported by Slot 0
OBJECT-TYPE    
  INTEGER idle(1), start(2), continue(3), end(4), ack(5), aborted(6), error(7)  

scatcommand 1.3.6.1.4.1.251.1.1.21.11.1.8
Internal Use
OBJECT-TYPE    
  INTEGER none(1), revert(2)  

scatplaceholder1 1.3.6.1.4.1.251.1.1.21.11.1.9
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

scatplaceholder2 1.3.6.1.4.1.251.1.1.21.11.1.10
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

scconoffline 1.3.6.1.4.1.251.1.1.21.11.1.11
Put NTM LIM on or offline
OBJECT-TYPE    
  INTEGER offline(1), online(2)  

pCATstatusTable 1.3.6.1.4.1.251.1.1.21.12
OBJECT-TYPE    
  SEQUENCE OF  
    PCATstatusEntry

pCATstatusEntry 1.3.6.1.4.1.251.1.1.21.12.1
OBJECT-TYPE    
  PCATstatusEntry  

pscIndex 1.3.6.1.4.1.251.1.1.21.12.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pscatlimtype 1.3.6.1.4.1.251.1.1.21.12.1.2
Type of NTM LIM detected
OBJECT-TYPE    
  INTEGER none(1), t1(2), e1(3)  

psCATFFrevision 1.3.6.1.4.1.251.1.1.21.12.1.3
NTM LIM Code Revision
OBJECT-TYPE    
  DisplayString  

psCATBootrevision 1.3.6.1.4.1.251.1.1.21.12.1.4
NTM LIM Boot Revision
OBJECT-TYPE    
  DisplayString  

pscatfilestatus 1.3.6.1.4.1.251.1.1.21.12.1.5
Flash file status
OBJECT-TYPE    
  INTEGER na(1), not-present(2), present(3)  

psCATfilerevision 1.3.6.1.4.1.251.1.1.21.12.1.6
NTM LIM file Revision
OBJECT-TYPE    
  DisplayString  

psCATHWrevision 1.3.6.1.4.1.251.1.1.21.12.1.7
NTM LIM Hardware Revision
OBJECT-TYPE    
  INTEGER  

pscatmode 1.3.6.1.4.1.251.1.1.21.12.1.8
Operating Mode of NTM LIM
OBJECT-TYPE    
  INTEGER no-card(3), boot(1), full-feature-offline(2), unknown(4), full-feature-in-dnld(5), boot-in-dnld(6), full-feature-online(7)  

pscaterrorcode 1.3.6.1.4.1.251.1.1.21.12.1.9
NTM LIM Error Code
OBJECT-TYPE    
  INTEGER none(1), bad-config(3), no-code(4), no-config(5), download-ok(6), download-fail(7)  

pscatplaceholder1 1.3.6.1.4.1.251.1.1.21.12.1.10
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

pscatplaceholder2 1.3.6.1.4.1.251.1.1.21.12.1.11
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

sCATstatusTable 1.3.6.1.4.1.251.1.1.21.13
OBJECT-TYPE    
  SEQUENCE OF  
    SCATstatusEntry

sCATstatusEntry 1.3.6.1.4.1.251.1.1.21.13.1
OBJECT-TYPE    
  SCATstatusEntry  

sscIndex 1.3.6.1.4.1.251.1.1.21.13.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sscatlimtype 1.3.6.1.4.1.251.1.1.21.13.1.2
Type of NTM LIM
OBJECT-TYPE    
  INTEGER none(1), t1(2), e1(3)  

ssCATFFrevision 1.3.6.1.4.1.251.1.1.21.13.1.3
NTM LIM Code Revision
OBJECT-TYPE    
  DisplayString  

ssCATBootrevision 1.3.6.1.4.1.251.1.1.21.13.1.4
NTM LIM Boot Revision
OBJECT-TYPE    
  DisplayString  

sscatfilestatus 1.3.6.1.4.1.251.1.1.21.13.1.5
Flash file status
OBJECT-TYPE    
  INTEGER na(1), not-present(2), present(3)  

ssCATfilerevision 1.3.6.1.4.1.251.1.1.21.13.1.6
NTM LIM file Revision
OBJECT-TYPE    
  DisplayString  

ssCATHWrevision 1.3.6.1.4.1.251.1.1.21.13.1.7
NTM LIM Hardware Revision
OBJECT-TYPE    
  INTEGER  

sscatmode 1.3.6.1.4.1.251.1.1.21.13.1.8
Operating mode of NTM LIM
OBJECT-TYPE    
  INTEGER no-card(3), boot(1), full-feature-offline(2), unknown(4), full-feature-in-dnld(5), boot-in-dnld(6), full-feature-online(7)  

sscaterrorcode 1.3.6.1.4.1.251.1.1.21.13.1.9
NTM LIM Error Code
OBJECT-TYPE    
  INTEGER none(1), no-cat(2), bad-config(3), no-code(4), no-config(5), download-ok(6), download-fail(7)  

sscatplaceholder1 1.3.6.1.4.1.251.1.1.21.13.1.10
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

sscatplaceholder2 1.3.6.1.4.1.251.1.1.21.13.1.11
Placeholder for future MIB changes
OBJECT-TYPE    
  INTEGER na(1)  

pCATStratum3ConfigTable 1.3.6.1.4.1.251.1.1.21.14
OBJECT-TYPE    
  SEQUENCE OF  
    PCATStratum3ConfigEntry

pCATStratum3ConfigEntry 1.3.6.1.4.1.251.1.1.21.14.1
OBJECT-TYPE    
  PCATStratum3ConfigEntry  

ps3cIndex 1.3.6.1.4.1.251.1.1.21.14.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pcatstr3listener 1.3.6.1.4.1.251.1.1.21.14.1.2
Configures Stratum 3 Reference
OBJECT-TYPE    
  INTEGER external(1), line(2)  

pcatstr3oscillator 1.3.6.1.4.1.251.1.1.21.14.1.3
Configures Stratum 3 Mode
OBJECT-TYPE    
  INTEGER external-or-line(1), internal(2)  

pcatstr3forcesecondary 1.3.6.1.4.1.251.1.1.21.14.1.4
Disables Stratum 3 Driver on Primary NTM LIM only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pcatstr3reconfigure 1.3.6.1.4.1.251.1.1.21.14.1.5
Re-configure Primary Stratum 3
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sCATStratum3ConfigTable 1.3.6.1.4.1.251.1.1.21.15
OBJECT-TYPE    
  SEQUENCE OF  
    SCATStratum3ConfigEntry

sCATStratum3ConfigEntry 1.3.6.1.4.1.251.1.1.21.15.1
OBJECT-TYPE    
  SCATStratum3ConfigEntry  

ss3cIndex 1.3.6.1.4.1.251.1.1.21.15.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

scatstr3listener 1.3.6.1.4.1.251.1.1.21.15.1.2
Configures Stratum 3 Reference
OBJECT-TYPE    
  INTEGER external(1), line(2)  

scatstr3oscillator 1.3.6.1.4.1.251.1.1.21.15.1.3
Configures Stratum 3 Mode
OBJECT-TYPE    
  INTEGER external-or-line(1), internal(2)  

scatstr3reconfigure 1.3.6.1.4.1.251.1.1.21.15.1.4
Re-configure Secondary Stratum 3
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pCATStratum3StatusTable 1.3.6.1.4.1.251.1.1.21.16
OBJECT-TYPE    
  SEQUENCE OF  
    PCATStratum3StatusEntry

pCATStratum3StatusEntry 1.3.6.1.4.1.251.1.1.21.16.1
OBJECT-TYPE    
  PCATStratum3StatusEntry  

ps3sIndex 1.3.6.1.4.1.251.1.1.21.16.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pcatstr3listenerstatus 1.3.6.1.4.1.251.1.1.21.16.1.2
What the Stratum 3 is referencing to
OBJECT-TYPE    
  INTEGER listening-to-Primary(1), listening-to-Secondary(2), no-input(3)  

pcatstr3driverstatus 1.3.6.1.4.1.251.1.1.21.16.1.3
What the Stratum 3 output is driving
OBJECT-TYPE    
  INTEGER enabled-online(1), disabled-offline(2), fault(3)  

pcatstr3oscstatus 1.3.6.1.4.1.251.1.1.21.16.1.4
Stratum 3 oscillator status
OBJECT-TYPE    
  INTEGER idle(1), acquisition-wide-band(2), locked-in-range(3), acquisition-narrow-band(4), holdover(5), internal(6)  

sCATStratum3StatusTable 1.3.6.1.4.1.251.1.1.21.17
OBJECT-TYPE    
  SEQUENCE OF  
    SCATStratum3StatusEntry

sCATStratum3StatusEntry 1.3.6.1.4.1.251.1.1.21.17.1
OBJECT-TYPE    
  SCATStratum3StatusEntry  

ss3sIndex 1.3.6.1.4.1.251.1.1.21.17.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

scatstr3listenerstatus 1.3.6.1.4.1.251.1.1.21.17.1.2
What the Stratum 3 Listener is referencing
OBJECT-TYPE    
  INTEGER listening-to-Primary(1), listening-to-secondary(2), no-input(3)  

scatstr3driverstatus 1.3.6.1.4.1.251.1.1.21.17.1.3
What the Stratum 3 output is driving
OBJECT-TYPE    
  INTEGER enabled-online(1), disabled-offline(2), fault(3)  

scatstr3oscstatus 1.3.6.1.4.1.251.1.1.21.17.1.4
Stratum 3 oscillator status
OBJECT-TYPE    
  INTEGER idle(1), acquisition-wide-band(2), locked-in-range(3), acquisition-narrow-band(4), holdover(5), internal(6)  

pCATBitsConfigTable 1.3.6.1.4.1.251.1.1.21.18
OBJECT-TYPE    
  SEQUENCE OF  
    PCATBitsConfigEntry

pCATBitsConfigEntry 1.3.6.1.4.1.251.1.1.21.18.1
OBJECT-TYPE    
  PCATBitsConfigEntry  

pbcIndex 1.3.6.1.4.1.251.1.1.21.18.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pbcds1V2TxLineLn 1.3.6.1.4.1.251.1.1.21.18.1.2
Select transmit line length
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-ft(7), na(8)  

pbcplaceholder1 1.3.6.1.4.1.251.1.1.21.18.1.3
Future Use
OBJECT-TYPE    
  INTEGER na(1)  

pbcV2FRMRMode 1.3.6.1.4.1.251.1.1.21.18.1.4
DS1 Framing options.
OBJECT-TYPE    
  INTEGER none(1), sf(2), esf(3)  

pbcds1V2Coding 1.3.6.1.4.1.251.1.1.21.18.1.5
T1 Line Code
OBJECT-TYPE    
  INTEGER na(3), ami(2), b8zs-t1(1)  

pbcV2Lb 1.3.6.1.4.1.251.1.1.21.18.1.6
Loopback Selection DS1
OBJECT-TYPE    
  INTEGER none(1), line-loopback(2), local-loopback(3)  

pbcclrperf 1.3.6.1.4.1.251.1.1.21.18.1.7
Clear the Performance Counters
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pbcreconfigure 1.3.6.1.4.1.251.1.1.21.18.1.9
Re-configure Primary External
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sCATBitsConfigTable 1.3.6.1.4.1.251.1.1.21.19
OBJECT-TYPE    
  SEQUENCE OF  
    SCATBitsConfigEntry

sCATBitsConfigEntry 1.3.6.1.4.1.251.1.1.21.19.1
OBJECT-TYPE    
  SCATBitsConfigEntry  

sbcIndex 1.3.6.1.4.1.251.1.1.21.19.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sbcds1V2TxLineLn 1.3.6.1.4.1.251.1.1.21.19.1.2
Select transmit line length
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-ft(7), na(8)  

sbcplaceholder1 1.3.6.1.4.1.251.1.1.21.19.1.3
Future Use
OBJECT-TYPE    
  INTEGER na(1)  

sbcV2FRMRMode 1.3.6.1.4.1.251.1.1.21.19.1.4
DS1 Framing options.
OBJECT-TYPE    
  INTEGER none(1), sf(2), esf(3)  

sbcds1V2Coding 1.3.6.1.4.1.251.1.1.21.19.1.5
T1 Line Coding
OBJECT-TYPE    
  INTEGER na(3), ami(2), b8zs(1)  

sbcV2Lb 1.3.6.1.4.1.251.1.1.21.19.1.6
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), line-loopback(2), local-loopback(3)  

sbcclrperf 1.3.6.1.4.1.251.1.1.21.19.1.7
Clear the Performance Counters
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sbcreconfigure 1.3.6.1.4.1.251.1.1.21.19.1.8
Re-configure Secondary External
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pCATBitsStatusTable 1.3.6.1.4.1.251.1.1.21.20
Ds1/E1 Bits Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    PCATBitsStatusEntry

pCATBitsStatusEntry 1.3.6.1.4.1.251.1.1.21.20.1
OBJECT-TYPE    
  PCATBitsStatusEntry  

pbsIndex 1.3.6.1.4.1.251.1.1.21.20.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pbslineok 1.3.6.1.4.1.251.1.1.21.20.1.2
Is the line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pbsV2RxAIS 1.3.6.1.4.1.251.1.1.21.20.1.3
Receive DS1 AIS(Blue)Alarm status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pbsV2RxLOS 1.3.6.1.4.1.251.1.1.21.20.1.4
Receive DS1 LOS status.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pbsV2RxOOF 1.3.6.1.4.1.251.1.1.21.20.1.5
Receive DS1 OOF status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pbsV2RxBER 1.3.6.1.4.1.251.1.1.21.20.1.6
Receive DS1 BER status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pbsV2RxOOFCnt 1.3.6.1.4.1.251.1.1.21.20.1.7
Receive DS1 OOF count.
OBJECT-TYPE    
  INTEGER  

pbsV2RxBERCnt 1.3.6.1.4.1.251.1.1.21.20.1.8
Receive DS1 BEE count.
OBJECT-TYPE    
  INTEGER  

pbsV2RxLOSCnt 1.3.6.1.4.1.251.1.1.21.20.1.9
Receive DS1 LOS count.
OBJECT-TYPE    
  INTEGER  

pbsV2LCVCnt 1.3.6.1.4.1.251.1.1.21.20.1.10
Receive DS1 LCV count.
OBJECT-TYPE    
  INTEGER  

sCATBitsStatusTable 1.3.6.1.4.1.251.1.1.21.21
Ds1/E1 Bits Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    SCATBitsStatusEntry

sCATBitsStatusEntry 1.3.6.1.4.1.251.1.1.21.21.1
OBJECT-TYPE    
  SCATBitsStatusEntry  

sbsIndex 1.3.6.1.4.1.251.1.1.21.21.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sbslineok 1.3.6.1.4.1.251.1.1.21.21.1.2
Is the line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sbsV2RxAIS 1.3.6.1.4.1.251.1.1.21.21.1.3
Receive DS1 AIS(Blue)Alarm status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sbsV2RxLOS 1.3.6.1.4.1.251.1.1.21.21.1.4
Receive DS1 LOS status.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sbsV2RxOOF 1.3.6.1.4.1.251.1.1.21.21.1.5
Receive DS1 OOF status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sbsV2RxBER 1.3.6.1.4.1.251.1.1.21.21.1.6
Receive DS1 BER status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sbsV2RxOOFCnt 1.3.6.1.4.1.251.1.1.21.21.1.7
Receive DS1 OOF Counts.
OBJECT-TYPE    
  INTEGER  

sbsV2RxBERCnt 1.3.6.1.4.1.251.1.1.21.21.1.8
Receive DS1 BEE Counts.
OBJECT-TYPE    
  INTEGER  

sbsV2RxLOSCnt 1.3.6.1.4.1.251.1.1.21.21.1.9
Receive DS1/E1 LOS Counts.
OBJECT-TYPE    
  INTEGER  

sbsV2LCVCnt 1.3.6.1.4.1.251.1.1.21.21.1.10
Receive DS1 AIS Counts.
OBJECT-TYPE    
  INTEGER  

pCATDerConfigTable 1.3.6.1.4.1.251.1.1.21.22
OBJECT-TYPE    
  SEQUENCE OF  
    PCATDerConfigEntry

pCATDerConfigEntry 1.3.6.1.4.1.251.1.1.21.22.1
OBJECT-TYPE    
  PCATDerConfigEntry  

pdcIndex 1.3.6.1.4.1.251.1.1.21.22.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pdcds1V2TxLineLn 1.3.6.1.4.1.251.1.1.21.22.1.2
Select transmit line length
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-ft(7), na(8)  

pdcplaceholder1 1.3.6.1.4.1.251.1.1.21.22.1.3
Future Use
OBJECT-TYPE    
  INTEGER na(1)  

pdcV2FRMRMode 1.3.6.1.4.1.251.1.1.21.22.1.4
DS1 Framing options.
OBJECT-TYPE    
  INTEGER none(1), sf(2), esf(3)  

pdcds1V2Coding 1.3.6.1.4.1.251.1.1.21.22.1.5
Line Code
OBJECT-TYPE    
  INTEGER na(3), ami(2), b8zs(1)  

pdcV2Lb 1.3.6.1.4.1.251.1.1.21.22.1.6
Loopback Selection
OBJECT-TYPE    
  INTEGER none(1), line-lpbk(2), local-loopback(3)  

pdcclrperf 1.3.6.1.4.1.251.1.1.21.22.1.7
Clear the performance counters
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pdcreconfigure 1.3.6.1.4.1.251.1.1.21.22.1.8
Re-configure Primary Line
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sCATDerConfigTable 1.3.6.1.4.1.251.1.1.21.23
OBJECT-TYPE    
  SEQUENCE OF  
    SCATDerConfigEntry

sCATDerConfigEntry 1.3.6.1.4.1.251.1.1.21.23.1
OBJECT-TYPE    
  SCATDerConfigEntry  

sdcIndex 1.3.6.1.4.1.251.1.1.21.23.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sdcds1V2TxLineLn 1.3.6.1.4.1.251.1.1.21.23.1.2
Select transmit line length
OBJECT-TYPE    
  INTEGER feet-0-110(1), feet-110-220(2), feet-220-330(3), feet-330-440(4), feet-440-550(5), feet-550-660(6), more-than-655-ft(7), na(8)  

sdcplaceholder1 1.3.6.1.4.1.251.1.1.21.23.1.3
Future Use
OBJECT-TYPE    
  INTEGER na(1)  

sdcV2FRMRMode 1.3.6.1.4.1.251.1.1.21.23.1.4
DS1 Framing options.
OBJECT-TYPE    
  INTEGER none(1), sf(2), esf(3)  

sdcds1V2Coding 1.3.6.1.4.1.251.1.1.21.23.1.5
Line Coding
OBJECT-TYPE    
  INTEGER na(3), ami(2), b8zs(1)  

sdcV2Lb 1.3.6.1.4.1.251.1.1.21.23.1.6
Loopback Selection DS1
OBJECT-TYPE    
  INTEGER none(1), line-lpbk(2), local-loopback(3)  

sdcclrperf 1.3.6.1.4.1.251.1.1.21.23.1.7
Clear the Performance Counters
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdcreconfigure 1.3.6.1.4.1.251.1.1.21.23.1.8
Re-configure Secondary Line
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pCATDerStatusTable 1.3.6.1.4.1.251.1.1.21.24
Ds1/E1 Derived Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    PCATDerStatusEntry

pCATDerStatusEntry 1.3.6.1.4.1.251.1.1.21.24.1
OBJECT-TYPE    
  PCATDerStatusEntry  

pdsIndex 1.3.6.1.4.1.251.1.1.21.24.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

pdslineok 1.3.6.1.4.1.251.1.1.21.24.1.2
Is the line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pdsV2TxReference 1.3.6.1.4.1.251.1.1.21.24.1.3
Transmit Reference Status
OBJECT-TYPE    
  INTEGER no-input(1), primary-valid(2), secondary-valid(3)  

pdsV2RxAIS 1.3.6.1.4.1.251.1.1.21.24.1.4
Receive DS1 AIS(Blue)Alarm status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pdsV2RxLOS 1.3.6.1.4.1.251.1.1.21.24.1.5
Receive DS1 LOS status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pdsV2RxOOF 1.3.6.1.4.1.251.1.1.21.24.1.6
Receive DS1 OOF status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pdsV2RxBER 1.3.6.1.4.1.251.1.1.21.24.1.7
Receive DS1 BER status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

pdsV2RxOOFCnt 1.3.6.1.4.1.251.1.1.21.24.1.8
Receive DS1 OOF count.
OBJECT-TYPE    
  INTEGER  

pdsV2RxBERCnt 1.3.6.1.4.1.251.1.1.21.24.1.9
Receive DS1 BEE count.
OBJECT-TYPE    
  INTEGER  

pdsV2RxLOSCnt 1.3.6.1.4.1.251.1.1.21.24.1.10
Receive DS1 LOS count.
OBJECT-TYPE    
  INTEGER  

pdsV2LCVCnt 1.3.6.1.4.1.251.1.1.21.24.1.11
Receive DS1 AIS count.
OBJECT-TYPE    
  INTEGER  

sCATDerStatusTable 1.3.6.1.4.1.251.1.1.21.25
Ds1/E1 Derived Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    SCATDerStatusEntry

sCATDerStatusEntry 1.3.6.1.4.1.251.1.1.21.25.1
OBJECT-TYPE    
  SCATDerStatusEntry  

sdsIndex 1.3.6.1.4.1.251.1.1.21.25.1.1
Entry Index
OBJECT-TYPE    
  INTEGER  

sdslineok 1.3.6.1.4.1.251.1.1.21.25.1.2
Is the line OK
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sdsV2TxReference 1.3.6.1.4.1.251.1.1.21.25.1.3
Transmit Reference Status
OBJECT-TYPE    
  INTEGER no-input(1), primary-valid(2), secondary-valid(3)  

sdsV2RxAIS 1.3.6.1.4.1.251.1.1.21.25.1.4
Receive DS1 AIS(Blue)Alarm status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sdsV2RxLOS 1.3.6.1.4.1.251.1.1.21.25.1.5
Receive DS1 LOS status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sdsV2RxOOF 1.3.6.1.4.1.251.1.1.21.25.1.6
Receive DS1 OOF status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sdsV2RxBER 1.3.6.1.4.1.251.1.1.21.25.1.7
Receive DS1 BER status.
OBJECT-TYPE    
  INTEGER no(1), yes(2), na(3)  

sdsV2RxOOFCnt 1.3.6.1.4.1.251.1.1.21.25.1.8
Receive DS1 OOF count.
OBJECT-TYPE    
  INTEGER  

sdsV2RxBERCnt 1.3.6.1.4.1.251.1.1.21.25.1.9
Receive DS1 BEE count.
OBJECT-TYPE    
  INTEGER  

sdsV2RxLOSCnt 1.3.6.1.4.1.251.1.1.21.25.1.10
Receive DS1 LOS count.
OBJECT-TYPE    
  INTEGER  

sdsV2LCVCnt 1.3.6.1.4.1.251.1.1.21.25.1.11
Receive DS1 AIS count.
OBJECT-TYPE    
  INTEGER  

sysClkAlarmErr 1.3.6.1.4.1.251.1.1.21.26
Defines the error type for the current clock alarm
OBJECT-TYPE    
  INTEGER none(1), sEClinePRI-ok(2), pRIlineSEC-ok(3), pRIlineSECoffline(4), pRIoscSECoffline(5), sEClinePRIoffline(6), sECoscPRIoffline(7), pRIlineSECline(8), pRIosc(9), sECosc(10), pRIoscSECosc(11), pRIoscSECline(12), pRIlineSECosc(13), no-valid-error(14)  

mjlimSlipLine 1.3.6.1.4.1.251.1.1.22
OBJECT IDENTIFIER    

reset040 1.3.6.1.4.1.251.1.1.22
This is sent when a the master processor is reset by operator
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  

jpegSlipIp 1.3.6.1.4.1.251.1.1.22.1
IP address of SLIP line.
OBJECT-TYPE    
  IpAddress  

jpegSlipMask 1.3.6.1.4.1.251.1.1.22.2
Mask for SLIP line.
OBJECT-TYPE    
  IpAddress  

jpegSlipRemoteIp 1.3.6.1.4.1.251.1.1.22.3
IP address of remote end of SLIP line.
OBJECT-TYPE    
  IpAddress  

jpegSlipSpeed 1.3.6.1.4.1.251.1.1.22.4
Baud rate of SLIP serial line.
OBJECT-TYPE    
  INTEGER baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5)  

mjlimSystem 1.3.6.1.4.1.251.1.1.23
OBJECT IDENTIFIER    

badPassword 1.3.6.1.4.1.251.1.1.23
This is sent when a user enters a bad password
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  

limSysState 1.3.6.1.4.1.251.1.1.23.1
M-JPEG LIM System State
OBJECT-TYPE    
  INTEGER init(1), idle(2), start(3), working(4), terminate(5), fault(6)  

limSysFault 1.3.6.1.4.1.251.1.1.23.2
M-JPEG LIM Hardware Fault - front panel lamp
OBJECT-TYPE    
  INTEGER on(1), off(2)  

limSysCompErr 1.3.6.1.4.1.251.1.1.23.3
M-JPEG LIM Compression Error - front panel lamp
OBJECT-TYPE    
  INTEGER on(1), off(2)  

limSysDecompErr 1.3.6.1.4.1.251.1.1.23.4
M-JPEG LIM Decompression Error - front panel lamp
OBJECT-TYPE    
  INTEGER on(1), off(2)  

limSysVideoIn 1.3.6.1.4.1.251.1.1.23.5
M-JPEG LIM Video Input Present - front panel lamp
OBJECT-TYPE    
  INTEGER on(1), off(2)  

limSysVideoOut 1.3.6.1.4.1.251.1.1.23.6
M-JPEG LIM Video Output Active - front panel lamp
OBJECT-TYPE    
  INTEGER on(1), off(2)  

limSysStartMode 1.3.6.1.4.1.251.1.1.23.30
M-JPEG LIM Default Startup mode
OBJECT-TYPE    
  INTEGER auto(1), force-init(2)  

vidInCfg 1.3.6.1.4.1.251.1.1.24
OBJECT IDENTIFIER    

vidInJpeg 1.3.6.1.4.1.251.1.1.24.1
M-JPEG LIM Video Input JPEG mode
OBJECT-TYPE    
  INTEGER start(1), stop(2)  

vidInRate 1.3.6.1.4.1.251.1.1.24.2
M-JPEG LIM Video Input Channel Bit Rate
OBJECT-TYPE    
  INTEGER mbps25(1), mbps20(2), mbps15(3), mbps10(4), mbps5(5)  

vidInProvMode 1.3.6.1.4.1.251.1.1.24.3
M-JPEG LIM Video Input Provisioning Mode
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

vidInFrameRate 1.3.6.1.4.1.251.1.1.24.4
M-JPEG LIM Video Input Frame Rate
OBJECT-TYPE    
  INTEGER full(1)  

vidInWindowSize 1.3.6.1.4.1.251.1.1.24.5
M-JPEG LIM Video Input Window size
OBJECT-TYPE    
  INTEGER full-screen(1), constrained(2)  

vidInQuanFactor 1.3.6.1.4.1.251.1.1.24.6
M-JPEG LIM Video Input Quantization factor
OBJECT-TYPE    
  INTEGER 10..100  

vidInTransMode 1.3.6.1.4.1.251.1.1.24.7
M-JPEG LIM Video Input Transmit Mode
OBJECT-TYPE    
  INTEGER cbr(1), capped-vbr(2)  

vidInStand 1.3.6.1.4.1.251.1.1.24.8
M-JPEG LIM Video Input Standard
OBJECT-TYPE    
  INTEGER ntsc(1), pal(2)  

vidInVcrMode 1.3.6.1.4.1.251.1.1.24.9
M-JPEG LIM Video Input VCR mode
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidInAnLpbk 1.3.6.1.4.1.251.1.1.24.10
M-JPEG LIM Video Input Analog Loopback
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidInTest 1.3.6.1.4.1.251.1.1.24.11
M-JPEG LIM Video Input Test Pattern
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidOutCfg 1.3.6.1.4.1.251.1.1.25
OBJECT IDENTIFIER    

vidOutJpeg 1.3.6.1.4.1.251.1.1.25.1
M-JPEG LIM Video Output JPEG Mode
OBJECT-TYPE    
  INTEGER start(1), stop(2)  

vidOutStand 1.3.6.1.4.1.251.1.1.25.2
M-JPEG LIM Video Output Standard
OBJECT-TYPE    
  INTEGER ntsc(1), pal(2), auto-sel(3)  

vidOutSource 1.3.6.1.4.1.251.1.1.25.3
M-JPEG LIM Video Output Timing Source
OBJECT-TYPE    
  INTEGER genlock(1), through(2), free(3)  

vidOutUnLpb 1.3.6.1.4.1.251.1.1.25.4
M-JPEG LIM Video Output Uncompressed Loopback
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidOutIdleSrc 1.3.6.1.4.1.251.1.1.25.5
M-JPEG LIM Video Output Idle Source
OBJECT-TYPE    
  INTEGER black(1), color(2)  

vidOutChnlLpbk 1.3.6.1.4.1.251.1.1.25.6
M-JPEG LIM Video Output Channel Loopback
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidInSta 1.3.6.1.4.1.251.1.1.26
OBJECT IDENTIFIER    

billingRecFail 1.3.6.1.4.1.251.1.1.26
Could not create billing record
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  

vidInState 1.3.6.1.4.1.251.1.1.26.1
M-JPEG LIM Video Input State
OBJECT-TYPE    
  INTEGER init(1), idle(2), start(3), working(4), terminate(5), fault(6)  

vidInPres 1.3.6.1.4.1.251.1.1.26.2
M-JPEG LIM Video Input Present Indicator
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidInCurQFactor 1.3.6.1.4.1.251.1.1.26.3
M-JPEG LIM Video Input Current Quality Factor
OBJECT-TYPE    
  INTEGER  

vidInCurFrameRate 1.3.6.1.4.1.251.1.1.26.4
M-JPEG LIM Video Input Current Frame Rate
OBJECT-TYPE    
  INTEGER  

vidInAvgBitRate 1.3.6.1.4.1.251.1.1.26.5
M-JPEG LIM Video Input Average Bitrate (Mpbs)
OBJECT-TYPE    
  INTEGER  

vidInPeakBitRate 1.3.6.1.4.1.251.1.1.26.6
M-JPEG LIM Video Input Peak Bitrate (Mbps)
OBJECT-TYPE    
  INTEGER  

vidInSubSample 1.3.6.1.4.1.251.1.1.26.7
M-JPEG LIM Video Input Field Subsample Status
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidInCompCnt 1.3.6.1.4.1.251.1.1.26.8
M-JPEG LIM Video Input Compressed Packet Count
OBJECT-TYPE    
  Counter  

vidInSkipCnt 1.3.6.1.4.1.251.1.1.26.9
M-JPEG LIM Video Input Skipped Packet Count
OBJECT-TYPE    
  Counter  

vidInBuffOvf 1.3.6.1.4.1.251.1.1.26.10
M-JPEG LIM Video Input Buffer Controller Overflow Count
OBJECT-TYPE    
  Counter  

vidInImageErr 1.3.6.1.4.1.251.1.1.26.11
M-JPEG LIM Video Input JPEG Chip FIFO Overflow
OBJECT-TYPE    
  Counter  

vidInFldSynErr 1.3.6.1.4.1.251.1.1.26.12
M-JPEG LIM Video Input Field Synchronization Errors
OBJECT-TYPE    
  Counter  

vidInCompErr 1.3.6.1.4.1.251.1.1.26.13
M-JPEG LIM Video Input Compression Errors
OBJECT-TYPE    
  Counter  

vidInBufLevel 1.3.6.1.4.1.251.1.1.26.14
M-JPEG LIM Video Input Buffer Fill Level (%)
OBJECT-TYPE    
  INTEGER  

vidInFailReason 1.3.6.1.4.1.251.1.1.26.15
M-JPEG LIM Video Input Fail Reason
OBJECT-TYPE    
  INTEGER none(1), ccube(2), timeout(3), channel(4), xilinx(5), badparms(6), algorithm(7)  

vidOutSta 1.3.6.1.4.1.251.1.1.27
OBJECT IDENTIFIER    

clockAlarm 1.3.6.1.4.1.251.1.1.27
Change in system clock alarm state: declare or clear minor/major alarms, describe error and location, includes primary/secondary clock locations and the active clock reference
TRAP-TYPE    
  alarmStatus  
  sysLastTrapMessage  
  sysClkAlarmErr  
  pSlotNumber  
  pSysRefSelect  
  sSlotNumber  
  sSysRefSelect  
  inService  

vidOutState 1.3.6.1.4.1.251.1.1.27.1
M-JPEG LIM Video Output state
OBJECT-TYPE    
  INTEGER init(1), idle(2), start(3), working(4), terminate(5), fault(6)  

vidOutRate 1.3.6.1.4.1.251.1.1.27.2
M-JPEG LIM Video Output Bitrate (Mbps)
OBJECT-TYPE    
  INTEGER  

vidOutFrameRate 1.3.6.1.4.1.251.1.1.27.3
M-JPEG LIM Video Output Frame Rate
OBJECT-TYPE    
  INTEGER  

vidOutWindowWidth 1.3.6.1.4.1.251.1.1.27.4
M-JPEG LIM Video Output Window Width
OBJECT-TYPE    
  INTEGER  

vidOutWindowHeight 1.3.6.1.4.1.251.1.1.27.5
M-JPEG LIM Video Output Window Height
OBJECT-TYPE    
  INTEGER  

vidOutChnlLock 1.3.6.1.4.1.251.1.1.27.6
M-JPEG LIM Video Output Channel Lock Indicator
OBJECT-TYPE    
  INTEGER on(1), off(2)  

vidOutPackets 1.3.6.1.4.1.251.1.1.27.7
M-JPEG LIM Video Output Packets Received Count
OBJECT-TYPE    
  Counter  

vidOutPlayed 1.3.6.1.4.1.251.1.1.27.8
M-JPEG LIM Video Output Packets Played Count
OBJECT-TYPE    
  Counter  

vidOutSkipped 1.3.6.1.4.1.251.1.1.27.9
M-JPEG LIM Video Output Skipped Packet Count
OBJECT-TYPE    
  Counter  

vidOutChnlErr 1.3.6.1.4.1.251.1.1.27.10
M-JPEG LIM Video Output Channel Error Count
OBJECT-TYPE    
  Counter  

vidOutBuffOvf 1.3.6.1.4.1.251.1.1.27.11
M-JPEG LIM Video Output Buffer Controller Overflow Count
OBJECT-TYPE    
  Counter  

vidOutImageErr 1.3.6.1.4.1.251.1.1.27.12
M-JPEG LIM Video Output JPEG Chip Error Count
OBJECT-TYPE    
  Counter  

vidOutSeqnoErr 1.3.6.1.4.1.251.1.1.27.13
M-JPEG LIM Video Output Packet Sequence Number Error Count
OBJECT-TYPE    
  Counter  

vidOutCurrQFactor 1.3.6.1.4.1.251.1.1.27.14
M-JPEG LIM Video Output Current JPEG Quantization Factor
OBJECT-TYPE    
  INTEGER  

vidOutStdStat 1.3.6.1.4.1.251.1.1.27.15
M-JPEG LIM Video Output Standard Status
OBJECT-TYPE    
  INTEGER ntsc(1), pal(2)  

vidOutBuffLevel 1.3.6.1.4.1.251.1.1.27.16
M-JPEG LIM Video Output Buffer Fill Level (%)
OBJECT-TYPE    
  INTEGER  

vidOutPktsInBuff 1.3.6.1.4.1.251.1.1.27.17
M-JPEG LIM Video Output Packets in Buffer
OBJECT-TYPE    
  INTEGER  

vidOutFailReason 1.3.6.1.4.1.251.1.1.27.18
M-JPEG LIM Video Output Fail Reason
OBJECT-TYPE    
  INTEGER none(1), ccube(2), timeout(3), channel(4), xilinx(5), badparms(6), algorithm(7)  

vidOutSrcSts 1.3.6.1.4.1.251.1.1.27.19
M-JPEG LIM Video Output Timing Source Status
OBJECT-TYPE    
  INTEGER genlock(1), through(2), free(3)  

audInCfg 1.3.6.1.4.1.251.1.1.28
OBJECT IDENTIFIER    

spvcInit 1.3.6.1.4.1.251.1.1.28
Call successfully established
TRAP-TYPE    
  sysLastTrapMessage  
  sPvcId  
  slotNumber  

audInLoopBack 1.3.6.1.4.1.251.1.1.28.1
M-JPEG LIM Audio Input LoopBack Mode
OBJECT-TYPE    
  INTEGER on(1), off(2)  

audOutCfg 1.3.6.1.4.1.251.1.1.29
OBJECT IDENTIFIER    

spvcFail 1.3.6.1.4.1.251.1.1.29
Call attempt failed
TRAP-TYPE    
  sysLastTrapMessage  
  sPvcId  
  slotNumber  
  sPvcCauseDiagCode  

audOutMute 1.3.6.1.4.1.251.1.1.29.1
M-JPEG LIM Audio Output Mute Control
OBJECT-TYPE    
  INTEGER on(1), off(2)  

audOutDigLpbk 1.3.6.1.4.1.251.1.1.29.2
M-JPEG LIM Audio Digital Loopback
OBJECT-TYPE    
  INTEGER on(1), off(2)  

audInSta 1.3.6.1.4.1.251.1.1.30
OBJECT IDENTIFIER    

spvcCallClr 1.3.6.1.4.1.251.1.1.30
Call cleared after established
TRAP-TYPE    
  sysLastTrapMessage  
  sPvcId  
  slotNumber  

audOutSta 1.3.6.1.4.1.251.1.1.31
OBJECT IDENTIFIER    

spvcCallReset 1.3.6.1.4.1.251.1.1.31
Call reset after established
TRAP-TYPE    
  sysLastTrapMessage  
  sPvcId  
  slotNumber  

audOutLock 1.3.6.1.4.1.251.1.1.31.1
M-JPEG LIM Audio Output Channel Lock Indicator
OBJECT-TYPE    
  INTEGER on(1), off(2)  

audOutMuteStat 1.3.6.1.4.1.251.1.1.31.2
M-JPEG LIM Audio Output Mute Status
OBJECT-TYPE    
  INTEGER on(1), off(2)  

dataCfg 1.3.6.1.4.1.251.1.1.32
OBJECT IDENTIFIER    

dataIp 1.3.6.1.4.1.251.1.1.32.1
IP address of Data Channel.
OBJECT-TYPE    
  IpAddress  

dataMask 1.3.6.1.4.1.251.1.1.32.2
Network Mask for Data Channel.
OBJECT-TYPE    
  IpAddress  

dataRemoteIp 1.3.6.1.4.1.251.1.1.32.3
IP address of remote end of Data Channel.
OBJECT-TYPE    
  IpAddress  

dataSta 1.3.6.1.4.1.251.1.1.33
OBJECT IDENTIFIER    

spvcRetryExceeded 1.3.6.1.4.1.251.1.1.33
Call attempts exceeded retry limit
TRAP-TYPE    
  sysLastTrapMessage  
  sPvcId  
  slotNumber  

mjlimControl 1.3.6.1.4.1.251.1.1.34
OBJECT IDENTIFIER    

sendFileSel 1.3.6.1.4.1.251.1.1.34.1
File to send
OBJECT-TYPE    
  INTEGER none(1), vjlim-cod(2), vjlca-cod(3)  

jpegCurrentFile 1.3.6.1.4.1.251.1.1.34.2
File being sent
OBJECT-TYPE    
  INTEGER none(1), vjlim-cod(2), vjlca-cod(3)  

sendFileStat 1.3.6.1.4.1.251.1.1.34.3
Status of file send
OBJECT-TYPE    
  INTEGER idle(1), start(2), continue(3), end(4), ack(5), aborted(6), error(7)  

sendFileBytes 1.3.6.1.4.1.251.1.1.34.4
Bytes sent
OBJECT-TYPE    
  INTEGER  

jpegReset 1.3.6.1.4.1.251.1.1.34.20
Hard/Soft Reset
OBJECT-TYPE    
  INTEGER no(1), reset(2)  

jpegSaveCfg 1.3.6.1.4.1.251.1.1.34.21
Save Configuration
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

jpegLoadCfg 1.3.6.1.4.1.251.1.1.34.22
Load Configuration
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

jpegSWRev 1.3.6.1.4.1.251.1.1.34.40
JPEG Code Revision
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

dv2PDH 1.3.6.1.4.1.251.1.1.35
OBJECT IDENTIFIER    

pdhPLCPTable 1.3.6.1.4.1.251.1.1.35.1
This table is used for PLCP configuration and status
OBJECT-TYPE    
  SEQUENCE OF  
    PdhPLCPEntry

pdhPLCPEntry 1.3.6.1.4.1.251.1.1.35.1.1
OBJECT-TYPE    
  PdhPLCPEntry  

pdhPLCPLinkNo 1.3.6.1.4.1.251.1.1.35.1.1.1
Link Number
OBJECT-TYPE    
  INTEGER 0..1  

pdhPLCPLinkEnable 1.3.6.1.4.1.251.1.1.35.1.1.2
Enable/Disable Link
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

pdhPLCPLinkStatusAffect 1.3.6.1.4.1.251.1.1.35.1.1.3
Link Status affect on receiving/transmitting
OBJECT-TYPE    
  INTEGER ignored(2), processed(1)  

pdhPLCPLinkState 1.3.6.1.4.1.251.1.1.35.1.1.4
Current Link State
OBJECT-TYPE    
  INTEGER up(1), down(2)  

pdhPLCPPhyMode 1.3.6.1.4.1.251.1.1.35.1.1.5
The physical framing for link
OBJECT-TYPE    
  INTEGER none(1), ds3(2), e3(3)  

pdhPLCPMode 1.3.6.1.4.1.251.1.1.35.1.1.6
The PLCP mode for link.
OBJECT-TYPE    
  INTEGER hec-based-delineation(1), ds1-PLCP(2), ds3-PLCP(3), e1-PLCP(4), e3-g751-PLCP(5)  

pdhPLCPScrambler 1.3.6.1.4.1.251.1.1.35.1.1.7
Enable/Disable scrambling
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

pdhPLCP0x55 1.3.6.1.4.1.251.1.1.35.1.1.8
Enable/Disable XORing HCS with 0x55
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

pdhPLCPSmdsMode 1.3.6.1.4.1.251.1.1.35.1.1.9
Enable/Disable SMDS mode
OBJECT-TYPE    
  INTEGER disabled(2), enabled(1)  

pdhPLCPIdleCell 1.3.6.1.4.1.251.1.1.35.1.1.10
Idle Cell Header Contents
OBJECT-TYPE    
  INTEGER unassigned(1), idle(2)  

pdhPLCPLoopback 1.3.6.1.4.1.251.1.1.35.1.1.11
PLCP Loopback
OBJECT-TYPE    
  INTEGER none(1), diagnostic-lpbk(2), line-lpbk(3), payload-lpbk(4), cell-lpbk(5)  

pdhPLCPClear 1.3.6.1.4.1.251.1.1.35.1.1.12
Clear PLCP counts
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPReconfig 1.3.6.1.4.1.251.1.1.35.1.1.13
Reconfigure link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPLpbkTimeout 1.3.6.1.4.1.251.1.1.35.1.1.14
This parameter is used to set the loopback timeout in minutes.
OBJECT-TYPE    
  INTEGER 1..604800  

pdhPLCPChipType 1.3.6.1.4.1.251.1.1.35.1.1.32
PDH Chip Type
OBJECT-TYPE    
  INTEGER plpp(1), suni-pdh(2), unknown(3)  

pdhPLCPTXclock 1.3.6.1.4.1.251.1.1.35.1.1.33
The state of TX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

pdhPLCPRXclock 1.3.6.1.4.1.251.1.1.35.1.1.34
The state of RX clock for this link.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

pdhPLCPTXCells 1.3.6.1.4.1.251.1.1.35.1.1.35
The transmit cells count for this link.
OBJECT-TYPE    
  Counter  

pdhPLCPRXCells 1.3.6.1.4.1.251.1.1.35.1.1.36
The receive cells count for this link.
OBJECT-TYPE    
  Counter  

pdhPLCPHCSErrs 1.3.6.1.4.1.251.1.1.35.1.1.37
The header checksum error count for this link.
OBJECT-TYPE    
  Counter  

pdhPLCPLOCDDefect 1.3.6.1.4.1.251.1.1.35.1.1.43
Loss of cell delineation Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPYellowDefect 1.3.6.1.4.1.251.1.1.35.1.1.44
PLCP Yellow Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPLOFDefect 1.3.6.1.4.1.251.1.1.35.1.1.45
PLCP Loss Of Frame Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPLOCDAlarm 1.3.6.1.4.1.251.1.1.35.1.1.49
Loss of cell delineation Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPYellowAlarm 1.3.6.1.4.1.251.1.1.35.1.1.50
PLCP Yellow Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPLOFAlarm 1.3.6.1.4.1.251.1.1.35.1.1.51
PLCP Loss Of Frame Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhPLCPFrameErrs 1.3.6.1.4.1.251.1.1.35.1.1.56
Number of PLCP frame errors
OBJECT-TYPE    
  Counter  

pdhPLCPBIP8Errs 1.3.6.1.4.1.251.1.1.35.1.1.57
Number of PLCP BIP-8 errors
OBJECT-TYPE    
  Counter  

pdhPLCPFEBEErrs 1.3.6.1.4.1.251.1.1.35.1.1.58
Number of PLCP FEBE errors
OBJECT-TYPE    
  Counter  

pdhPLCPES 1.3.6.1.4.1.251.1.1.35.1.1.63
PLCP Errored Seconds
OBJECT-TYPE    
  Counter  

pdhPLCPSES 1.3.6.1.4.1.251.1.1.35.1.1.64
PLCP Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhPLCPUAS 1.3.6.1.4.1.251.1.1.35.1.1.65
PLCP Unavailable Seconds
OBJECT-TYPE    
  Counter  

pdhPLCPFEES 1.3.6.1.4.1.251.1.1.35.1.1.66
PLCP Far End Errored Seconds
OBJECT-TYPE    
  Counter  

pdhPLCPFESES 1.3.6.1.4.1.251.1.1.35.1.1.67
PLCP Far End Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhPLCPFEUAS 1.3.6.1.4.1.251.1.1.35.1.1.68
PLCP Far End Unavailable Seconds
OBJECT-TYPE    
  Counter  

pdhDS3Table 1.3.6.1.4.1.251.1.1.35.2
This table is used for DS3 config/status supplied by the PLPP chip
OBJECT-TYPE    
  SEQUENCE OF  
    PdhDS3Entry

pdhDS3Entry 1.3.6.1.4.1.251.1.1.35.2.1
OBJECT-TYPE    
  PdhDS3Entry  

pdhDS3TableValid 1.3.6.1.4.1.251.1.1.35.2.1.1
Indicates if table is valid for configured LIM
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3LinkNo 1.3.6.1.4.1.251.1.1.35.2.1.2
Link Number
OBJECT-TYPE    
  INTEGER 0..1  

pdhDS3Framer 1.3.6.1.4.1.251.1.1.35.2.1.3
DS3 framer mode
OBJECT-TYPE    
  INTEGER c-bit(1), m23(2)  

pdhDS3TxAIS 1.3.6.1.4.1.251.1.1.35.2.1.4
Transmit AIS
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3Clear 1.3.6.1.4.1.251.1.1.35.2.1.5
Clear Button for Counters
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pdhDS3Reconfig 1.3.6.1.4.1.251.1.1.35.2.1.6
Reconfigure link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3RxFrmFmt 1.3.6.1.4.1.251.1.1.35.2.1.26
Receive framing format
OBJECT-TYPE    
  INTEGER c-bit(1), clear-channel(2)  

pdhDS3RxIDL 1.3.6.1.4.1.251.1.1.35.2.1.27
Receive IDLE status
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3FEACTxmt 1.3.6.1.4.1.251.1.1.35.2.1.28
Code that has been transmitted as a FEAC.
OBJECT-TYPE    
  INTEGER none(7), line-loopback-active(6), line-loopback-deactive(5), ds3-idl(4), ds3-ais(3), ds3-oof(2), ds3-los(1)  

pdhDS3Lcvs 1.3.6.1.4.1.251.1.1.35.2.1.33
DS3 Line Code Violation count
OBJECT-TYPE    
  Counter  

pdhDS3FrameErrs 1.3.6.1.4.1.251.1.1.35.2.1.34
DS3 frame error count
OBJECT-TYPE    
  Counter  

pdhDS3ParityErrs 1.3.6.1.4.1.251.1.1.35.2.1.35
DS3 parity error count
OBJECT-TYPE    
  Counter  

pdhDS3CbitPrtyErrs 1.3.6.1.4.1.251.1.1.35.2.1.36
DS3 C-bit parity error count
OBJECT-TYPE    
  Counter  

pdhDS3FEBEErrs 1.3.6.1.4.1.251.1.1.35.2.1.37
DS3 FEBE error count
OBJECT-TYPE    
  Counter  

pdhDS3LOSDefect 1.3.6.1.4.1.251.1.1.35.2.1.43
DS3 Loss of Signal Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3OOFDefect 1.3.6.1.4.1.251.1.1.35.2.1.44
DS3 Out of Frame Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3AISDefect 1.3.6.1.4.1.251.1.1.35.2.1.45
Receive DS3 AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3YellowDefect 1.3.6.1.4.1.251.1.1.35.2.1.46
DS3 Yellow Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3ExBERDefect 1.3.6.1.4.1.251.1.1.35.2.1.47
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3LOSAlarm 1.3.6.1.4.1.251.1.1.35.2.1.53
DS3 Loss of Signal Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3LOFAlarm 1.3.6.1.4.1.251.1.1.35.2.1.54
DS3 Loss of Frame Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3AISAlarm 1.3.6.1.4.1.251.1.1.35.2.1.55
Receive DS3 AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3YellowAlarm 1.3.6.1.4.1.251.1.1.35.2.1.56
DS3 Yellow Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3ExBERAlarm 1.3.6.1.4.1.251.1.1.35.2.1.57
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhDS3LES 1.3.6.1.4.1.251.1.1.35.2.1.63
Line Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3LSES 1.3.6.1.4.1.251.1.1.35.2.1.64
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3ES 1.3.6.1.4.1.251.1.1.35.2.1.65
Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3ES2 1.3.6.1.4.1.251.1.1.35.2.1.66
Secondary Errored Seconds (C-bit mode only)
OBJECT-TYPE    
  Counter  

pdhDS3SES 1.3.6.1.4.1.251.1.1.35.2.1.67
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3SES2 1.3.6.1.4.1.251.1.1.35.2.1.68
Secondary Severely Errored Seconds (C-bit mode only)
OBJECT-TYPE    
  Counter  

pdhDS3AISS 1.3.6.1.4.1.251.1.1.35.2.1.69
AIS Seconds
OBJECT-TYPE    
  Counter  

pdhDS3UAS 1.3.6.1.4.1.251.1.1.35.2.1.70
Unavailable Seconds
OBJECT-TYPE    
  Counter  

pdhDS3FarEndES 1.3.6.1.4.1.251.1.1.35.2.1.71
Far End Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3FarEndSES 1.3.6.1.4.1.251.1.1.35.2.1.72
Far End Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhDS3FarEndUAS 1.3.6.1.4.1.251.1.1.35.2.1.73
Far End Unavailable Seconds
OBJECT-TYPE    
  Counter  

pdhE3Table 1.3.6.1.4.1.251.1.1.35.3
This table is used for E3 config/status supplied by the PLPP chip
OBJECT-TYPE    
  SEQUENCE OF  
    PdhE3Entry

pdhE3Entry 1.3.6.1.4.1.251.1.1.35.3.1
OBJECT-TYPE    
  PdhE3Entry  

pdhE3TableValid 1.3.6.1.4.1.251.1.1.35.3.1.1
Indicates if table is valid for configured LIM
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3LinkNo 1.3.6.1.4.1.251.1.1.35.3.1.2
Link Number
OBJECT-TYPE    
  INTEGER 0..1  

pdhE3Framer 1.3.6.1.4.1.251.1.1.35.3.1.3
E3 framer mode
OBJECT-TYPE    
  INTEGER g832(2), g751(1)  

pdhE3Clear 1.3.6.1.4.1.251.1.1.35.3.1.4
Clear Button for Counters
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pdhE3Reconfig 1.3.6.1.4.1.251.1.1.35.3.1.5
Reconfigure link
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3TxmtTimMk 1.3.6.1.4.1.251.1.1.35.3.1.6
Set to yes(1) if traceable to primary ref clk.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pdhE3PloadTypeLab 1.3.6.1.4.1.251.1.1.35.3.1.7
Payload type label.
OBJECT-TYPE    
  INTEGER atm(2)  

pdhE3TxTrlTrcIdLen 1.3.6.1.4.1.251.1.1.35.3.1.8
Trail trace length for transmit and expected receive.
OBJECT-TYPE    
  INTEGER length-16(16)  

pdhE3TxTrcIdUH 1.3.6.1.4.1.251.1.1.35.3.1.9
Transmit trail trace ID upper half.
OBJECT-TYPE    
  PhysAddress  

pdhE3TxTrcIdLH 1.3.6.1.4.1.251.1.1.35.3.1.10
Transmit trail trace ID lower half.
OBJECT-TYPE    
  PhysAddress  

pdhE3RxExTrcIdUH 1.3.6.1.4.1.251.1.1.35.3.1.11
Receive expected trail trace ID upper half.
OBJECT-TYPE    
  PhysAddress  

pdhE3RxExTrcIdLH 1.3.6.1.4.1.251.1.1.35.3.1.12
Receive expected trail trace ID lower half.
OBJECT-TYPE    
  PhysAddress  

pdhE3FrameErrs 1.3.6.1.4.1.251.1.1.35.3.1.32
E3 frame error count
OBJECT-TYPE    
  Counter  

pdhE3Lcvs 1.3.6.1.4.1.251.1.1.35.3.1.33
E3 Line Code Violation count
OBJECT-TYPE    
  Counter  

pdhE3ParityErrs 1.3.6.1.4.1.251.1.1.35.3.1.34
E3-G832 parity error count
OBJECT-TYPE    
  Counter  

pdhE3FEBEErrs 1.3.6.1.4.1.251.1.1.35.3.1.35
E3-G832 FEBE error count
OBJECT-TYPE    
  Counter  

pdhE3LOSDefect 1.3.6.1.4.1.251.1.1.35.3.1.41
LOS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3OOFDefect 1.3.6.1.4.1.251.1.1.35.3.1.42
LOF Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3AISDefect 1.3.6.1.4.1.251.1.1.35.3.1.43
AIS Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3FERFDefect 1.3.6.1.4.1.251.1.1.35.3.1.44
FERF Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3ExBERDefect 1.3.6.1.4.1.251.1.1.35.3.1.45
Excessive Bit Error Rate Defect
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3LOSAlarm 1.3.6.1.4.1.251.1.1.35.3.1.51
LOS Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3LOFAlarm 1.3.6.1.4.1.251.1.1.35.3.1.52
LOF Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3AISAlarm 1.3.6.1.4.1.251.1.1.35.3.1.53
AIS Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3FERFAlarm 1.3.6.1.4.1.251.1.1.35.3.1.54
FERF Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3ExBERAlarm 1.3.6.1.4.1.251.1.1.35.3.1.55
Excessive Bit Error Rate Alarm
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3LES 1.3.6.1.4.1.251.1.1.35.3.1.61
Line Errored Seconds
OBJECT-TYPE    
  Counter  

pdhE3LSES 1.3.6.1.4.1.251.1.1.35.3.1.62
Line Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhE3ES 1.3.6.1.4.1.251.1.1.35.3.1.63
Errored Seconds
OBJECT-TYPE    
  Counter  

pdhE3SES 1.3.6.1.4.1.251.1.1.35.3.1.64
Severely Errored Seconds
OBJECT-TYPE    
  Counter  

pdhE3AISS 1.3.6.1.4.1.251.1.1.35.3.1.65
AIS Seconds
OBJECT-TYPE    
  Counter  

pdhE3UAS 1.3.6.1.4.1.251.1.1.35.3.1.66
Unavailable Seconds
OBJECT-TYPE    
  Counter  

pdhE3RxTrlTrc 1.3.6.1.4.1.251.1.1.35.3.1.76
Last received trail trace message.
OBJECT-TYPE    
  PhysAddress SIZE(16)  

pdhE3RxTrIdMis 1.3.6.1.4.1.251.1.1.35.3.1.77
Receive trace id mismatch indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3RxTrIdUnst 1.3.6.1.4.1.251.1.1.35.3.1.78
Receive trace id unstable indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3RxPloadTypeLabMis 1.3.6.1.4.1.251.1.1.35.3.1.79
Receive payload type label mismatch indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

pdhE3RxPloadTypeLabUnst 1.3.6.1.4.1.251.1.1.35.3.1.80
Receive payload type label unstable indication.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

dv2Oam 1.3.6.1.4.1.251.1.1.36
OBJECT IDENTIFIER    

oamTable 1.3.6.1.4.1.251.1.1.36.1
This table is used for per-port OAM configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    OamEntry

oamEntry 1.3.6.1.4.1.251.1.1.36.1.1
OBJECT-TYPE    
  OamEntry  

oamLinkNo 1.3.6.1.4.1.251.1.1.36.1.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..3  

oamSegEndPoint 1.3.6.1.4.1.251.1.1.36.1.1.2
Set to yes(1) to configure the link as segment end point.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

oamVcEndPoint 1.3.6.1.4.1.251.1.1.36.1.1.3
Set to yes(1) to configure the link as connection end point.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

oamAisRdiGeneration 1.3.6.1.4.1.251.1.1.36.1.1.4
Set to yes(1) to generate AIS/RDI up on physical failure.
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

oamLastRxType 1.3.6.1.4.1.251.1.1.36.1.1.5
Type of the last received OAM cell.
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), loopback(3), continuity-check(4), performance-monitoring(5), unsupported(6), none(10)  

oamLastRxVpi 1.3.6.1.4.1.251.1.1.36.1.1.6
VPI value of the last received OAM cell.
OBJECT-TYPE    
  VirtualPathIdentifier  

oamLastRxVci 1.3.6.1.4.1.251.1.1.36.1.1.7
VCI value of the last received OAM cell.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

oamRxCount 1.3.6.1.4.1.251.1.1.36.1.1.8
Sum of received OAM cells.
OBJECT-TYPE    
  Counter  

oamLastTxType 1.3.6.1.4.1.251.1.1.36.1.1.9
Type of the last transmitted OAM cell.
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), loopback(3), continuity-check(4), performance-monitoring(5), unsupported(6), none(10)  

oamLastTxVpi 1.3.6.1.4.1.251.1.1.36.1.1.10
VPI value of the last transmitted OAM cell.
OBJECT-TYPE    
  VirtualPathIdentifier  

oamLastTxVci 1.3.6.1.4.1.251.1.1.36.1.1.11
VCI value of the last transmitted OAM cell.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

oamTxCount 1.3.6.1.4.1.251.1.1.36.1.1.12
Sum of transmitted OAM cells.
OBJECT-TYPE    
  Counter  

oamClearStats 1.3.6.1.4.1.251.1.1.36.1.1.13
Set to yes(2) to clear OAM Tx and Rx Statistics.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

oamLoopbackTable 1.3.6.1.4.1.251.1.1.36.2
This table is used to configure and control loopback test. Change Test Status to Start Test(1) to initiate loopback test.
OBJECT-TYPE    
  SEQUENCE OF  
    OamLoopbackEntry

oamLoopbackEntry 1.3.6.1.4.1.251.1.1.36.2.1
OBJECT-TYPE    
  OamLoopbackEntry  

oamLoopbackLinkNo 1.3.6.1.4.1.251.1.1.36.2.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

oamLoopbackVpi 1.3.6.1.4.1.251.1.1.36.2.1.2
VPI value for the loopback cells to send.
OBJECT-TYPE    
  VirtualPathIdentifier  

oamLoopbackVci 1.3.6.1.4.1.251.1.1.36.2.1.3
VCI value for the loopback cells to send.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

oamLoopbackSpan 1.3.6.1.4.1.251.1.1.36.2.1.4
Flow span for the loopback cells to send.
OBJECT-TYPE    
  INTEGER segment(4), end-to-end(5), location-id(6)  

oamLoopbackMaxNumCells 1.3.6.1.4.1.251.1.1.36.2.1.5
Maximum number of loopback cells to send.
OBJECT-TYPE    
  INTEGER 1..20  

oamLoopbackNumCellsSent 1.3.6.1.4.1.251.1.1.36.2.1.6
Number of loopback cells sent.
OBJECT-TYPE    
  INTEGER 0..20  

oamLoopbackTimeOut 1.3.6.1.4.1.251.1.1.36.2.1.7
Number of seconds to wait for loopback cells to return.
OBJECT-TYPE    
  INTEGER 1..10  

oamLoopbackActive 1.3.6.1.4.1.251.1.1.36.2.1.8
Change to Start Test to run loopback test.
OBJECT-TYPE    
  INTEGER start-test(1), complete(2), idle(3), under-test(4)  

oamLoopbackResult 1.3.6.1.4.1.251.1.1.36.2.1.9
Loopback test result.
OBJECT-TYPE    
  INTEGER pass(1), fail(2), physical-loopback-detected(3), unknown(4), vpi-range-error(5), vp-is-invalid(6), vci-range-error(7), vci-and-span-mismatch(8), vpc-not-established(9), vcc-not-established(10)  

oamLoopbackLocId 1.3.6.1.4.1.251.1.1.36.2.1.10
Location Node ID for loopback point.
OBJECT-TYPE    
  INTEGER 0..255  

oamDisable 1.3.6.1.4.1.251.1.1.36.3
yes(2) will disable the oam for entire slot.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

oamVcaTable 1.3.6.1.4.1.251.1.1.36.4
This table is used for per-port OAM configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    OamVcaEntry

oamVcaEntry 1.3.6.1.4.1.251.1.1.36.4.1
OBJECT-TYPE    
  OamVcaEntry  

oamVcaVpi 1.3.6.1.4.1.251.1.1.36.4.1.1
The VPI for this configuration.
OBJECT-TYPE    
  VirtualPathIdentifier  

oamVcaVci 1.3.6.1.4.1.251.1.1.36.4.1.2
The VCI for this configuration.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

oamVcaConnectionType 1.3.6.1.4.1.251.1.1.36.4.1.3
Set End point configuration on hardware per VPC/VCC
OBJECT-TYPE    
  INTEGER connection-point(1), segment-endpoint(2), end-to-end-endpoint(3), pass-thru(4)  

oamVcaVpcEndPoint 1.3.6.1.4.1.251.1.1.36.4.1.4
Set yes(1) to configure the VC to VPC end point.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

oamVcaAisRdiGeneration 1.3.6.1.4.1.251.1.1.36.4.1.5
AIS/RDI disable or enable with or without traps.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

oamVcaAisRdiState 1.3.6.1.4.1.251.1.1.36.4.1.6
AIS/RDI state for this VP/VC.
OBJECT-TYPE    
  INTEGER none(1), ais(2), rdi(3)  

oamVcaDefectType 1.3.6.1.4.1.251.1.1.36.4.1.7
AIS/RDI defect type.
OBJECT-TYPE    
  INTEGER none(1), link-down(2), loss-of-continuity(3), unknown(4)  

oamVcaDefectNode 1.3.6.1.4.1.251.1.1.36.4.1.8
AIS/RDI location.
OBJECT-TYPE    
  INTEGER 0..255  

oamVcaDefectSlot 1.3.6.1.4.1.251.1.1.36.4.1.9
AIS/RDI location.
OBJECT-TYPE    
  INTEGER 0..15  


oamVcaTrapEnable 1.3.6.1.4.1.251.1.1.36.4.1.11
Set enable to generate trap when AIS/RDI received.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

oamVcaCC 1.3.6.1.4.1.251.1.1.36.4.1.12
Activate segment or end to end Continuity Checks.
OBJECT-TYPE    
  INTEGER none(1), act-source-seg-cell(2), act-source-ee-cell(3), act-sink-seg-cell(4), act-sink-ee-cell(5), act-bidir-seg-cell(6), act-bidir-ee-cell(7), act-source-seg-manual(8), act-source-ee-manual(9), act-sink-seg-manual(10), act-sink-ee-manual(11), act-bidir-seg-manual(12), act-bidir-ee-manual(13)  

oamVcaCCState 1.3.6.1.4.1.251.1.1.36.4.1.13
Continuity Check state.
OBJECT-TYPE    
  INTEGER not-supported(1), ready(2), wait-act-con(3), wait-act-res(4), wait-deact-con(5), active-cell(6), active-manual(7)  

oamVcaPM 1.3.6.1.4.1.251.1.1.36.4.1.14
Activate segment or end to end Performance Monitoring.
OBJECT-TYPE    
  INTEGER none(1), act-source-seg-cell(2), act-source-ee-cell(3), act-sink-seg-cell(4), act-sink-ee-cell(5), act-source-seg-manual(6), act-source-ee-manual(7), act-sink-seg-manual(8), act-sink-ee-manual(9)  

oamVcaPMBlockSize 1.3.6.1.4.1.251.1.1.36.4.1.15
Performance Monitoring block size.
OBJECT-TYPE    
  INTEGER size128(1), size256(2), size512(3), size1024(4)  

oamVcaPMState 1.3.6.1.4.1.251.1.1.36.4.1.16
Continuity Check state.
OBJECT-TYPE    
  INTEGER not-supported(1), ready(2), wait-act-con(3), wait-act-res(4), wait-deact-con(5), active-cell(6), active-manual(7)  

oamVcaBkwRptLosCells 1.3.6.1.4.1.251.1.1.36.4.1.17
Backward Reporting loss of cell.
OBJECT-TYPE    
  INTEGER  

oamVcaBkwRptMisCells 1.3.6.1.4.1.251.1.1.36.4.1.18
Backward Reporting misinserted cell.
OBJECT-TYPE    
  INTEGER  

oamVcaBkwRptBip16 1.3.6.1.4.1.251.1.1.36.4.1.19
Backward Reporting BIP-16 violations.
OBJECT-TYPE    
  INTEGER  

oamVcaBkwRptSevErr 1.3.6.1.4.1.251.1.1.36.4.1.20
Backward Reporting Severly Errored Cells.
OBJECT-TYPE    
  INTEGER  

oamVcbTable 1.3.6.1.4.1.251.1.1.36.5
This table is used for per-port OAM configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    OamVcbEntry

oamVcbEntry 1.3.6.1.4.1.251.1.1.36.5.1
OBJECT-TYPE    
  OamVcbEntry  

oamVcbVpi 1.3.6.1.4.1.251.1.1.36.5.1.1
The VPI for this configuration.
OBJECT-TYPE    
  VirtualPathIdentifier  

oamVcbVci 1.3.6.1.4.1.251.1.1.36.5.1.2
The VCI for this configuration.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

oamVcbConnectionType 1.3.6.1.4.1.251.1.1.36.5.1.3
Set End point configuration on hardware per VPC/VCC
OBJECT-TYPE    
  INTEGER connection-point(1), segment-endpoint(2), end-to-end-endpoint(3), pass-thru(4)  

oamVcbVpcEndPoint 1.3.6.1.4.1.251.1.1.36.5.1.4
Set yes(1) to configure the VC to VPC end point.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

oamVcbAisRdiGeneration 1.3.6.1.4.1.251.1.1.36.5.1.5
AIS/RDI disable or enable with or without traps.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

oamVcbAisRdiState 1.3.6.1.4.1.251.1.1.36.5.1.6
AIS/RDI state for this VP/VC.
OBJECT-TYPE    
  INTEGER none(1), ais(2), rdi(3)  

oamVcbDefectType 1.3.6.1.4.1.251.1.1.36.5.1.7
AIS/RDI defect type.
OBJECT-TYPE    
  INTEGER none(1), link-down(2), loss-of-continuity(3), unknown(4)  

oamVcbDefectNode 1.3.6.1.4.1.251.1.1.36.5.1.8
AIS/RDI location.
OBJECT-TYPE    
  INTEGER 0..255  

oamVcbDefectSlot 1.3.6.1.4.1.251.1.1.36.5.1.9
AIS/RDI location.
OBJECT-TYPE    
  INTEGER 0..15  


oamVcbTrapEnable 1.3.6.1.4.1.251.1.1.36.5.1.11
Set enable to generate trap when AIS/RDI received.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

oamVcbCC 1.3.6.1.4.1.251.1.1.36.5.1.12
Activate segment or end to end Continuity Checks.
OBJECT-TYPE    
  INTEGER none(1), act-source-seg-cell(2), act-source-ee-cell(3), act-sink-seg-cell(4), act-sink-ee-cell(5), act-bidir-seg-cell(6), act-bidir-ee-cell(7), act-source-seg-manual(8), act-source-ee-manual(9), act-sink-seg-manual(10), act-sink-ee-manual(11), act-bidir-seg-manual(12), act-bidir-ee-manual(13)  

oamVcbCCState 1.3.6.1.4.1.251.1.1.36.5.1.13
Continuity Check state.
OBJECT-TYPE    
  INTEGER not-supported(1), ready(2), wait-act-con(3), wait-act-res(4), wait-deact-con(5), active-cell(6), active-manual(7)  

oamVcbPM 1.3.6.1.4.1.251.1.1.36.5.1.14
Activate segment or end to end Performance Monitoring.
OBJECT-TYPE    
  INTEGER none(1), act-source-seg-cell(2), act-source-ee-cell(3), act-sink-seg-cell(4), act-sink-ee-cell(5), act-source-seg-manual(6), act-source-ee-manual(7), act-sink-seg-manual(8), act-sink-ee-manual(9)  

oamVcbPMBlockSize 1.3.6.1.4.1.251.1.1.36.5.1.15
Performance Monitoring block size.
OBJECT-TYPE    
  INTEGER size128(1), size256(2), size512(3), size1024(4)  

oamVcbPMState 1.3.6.1.4.1.251.1.1.36.5.1.16
Continuity Check state.
OBJECT-TYPE    
  INTEGER not-supported(1), ready(2), wait-act-con(3), wait-act-res(4), wait-deact-con(5), active-cell(6), active-manual(7)  

oamVcbBkwRptLosCells 1.3.6.1.4.1.251.1.1.36.5.1.17
Backward Reporting loss of cell.
OBJECT-TYPE    
  INTEGER  

oamVcbBkwRptMisCells 1.3.6.1.4.1.251.1.1.36.5.1.18
Backward Reporting misinserted cell.
OBJECT-TYPE    
  INTEGER  

oamVcbBkwRptBip16 1.3.6.1.4.1.251.1.1.36.5.1.19
Backward Reporting BIP-16 violations.
OBJECT-TYPE    
  INTEGER  

oamVcbBkwRptSevErr 1.3.6.1.4.1.251.1.1.36.5.1.20
Backward Reporting Severly Errored Cells.
OBJECT-TYPE    
  INTEGER  

dv2Lmi 1.3.6.1.4.1.251.1.1.37
OBJECT IDENTIFIER    

lmiTable 1.3.6.1.4.1.251.1.1.37.1
This table is used to control ILMI configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    LmiEntry

lmiEntry 1.3.6.1.4.1.251.1.1.37.1.1
OBJECT-TYPE    
  LmiEntry  

lmiLinkNo 1.3.6.1.4.1.251.1.1.37.1.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

lmiVpi 1.3.6.1.4.1.251.1.1.37.1.1.2
The VPI used for ILMI.
OBJECT-TYPE    
  VirtualPathIdentifier  

lmiVci 1.3.6.1.4.1.251.1.1.37.1.1.3
The VCI used for ILMI.
OBJECT-TYPE    
  VirtualCircuitIdentifier  

lmiType 1.3.6.1.4.1.251.1.1.37.1.1.4
Set to network side (1) to configure the link as network side ILMI.
OBJECT-TYPE    
  INTEGER network-side(1), user-side(2)  

lmiState 1.3.6.1.4.1.251.1.1.37.1.1.5
The state of ILMI for this link.
OBJECT-TYPE    
  INTEGER initialized(1), connecting(2), registered(3), registering(4), deregistering(5), polling(6), disconnecting(7)  

lmiFormat 1.3.6.1.4.1.251.1.1.37.1.1.6
ILMI address format.
OBJECT-TYPE    
  INTEGER nsap-e-164(1), nsap-dcc(2), nsap-icd(3), non-nsap-e-164(4)  

lmiPrefix 1.3.6.1.4.1.251.1.1.37.1.1.7
Default Network prefix to use.
OBJECT-TYPE    
  E164SUB  

lmiOnOff 1.3.6.1.4.1.251.1.1.37.1.1.8
Turn on/off ILMI.
OBJECT-TYPE    
  INTEGER off(1), on(2), re-register(3)  

lmiPollPeriod 1.3.6.1.4.1.251.1.1.37.1.1.9
Period in seconds to send polling request for link management.
OBJECT-TYPE    
  INTEGER 3..10  

lmiNoRspDown 1.3.6.1.4.1.251.1.1.37.1.1.10
Number of failed polls (no response) before declaration of link down.
OBJECT-TYPE    
  INTEGER 2..10  

lmiLinkMgmt 1.3.6.1.4.1.251.1.1.37.1.1.11
Turn on/off link management.
OBJECT-TYPE    
  INTEGER on(2), off(1)  

lmiConnectivity 1.3.6.1.4.1.251.1.1.37.1.1.12
ATM interface status.
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

lmiPrefixMod 1.3.6.1.4.1.251.1.1.37.1.1.13
Modifiable Network prefix to use. MUST BE 26 DIGITS
OBJECT-TYPE    
  E164  

lmiEsi 1.3.6.1.4.1.251.1.1.37.1.1.14
ESI field to use on User side. MUST BE 12 DIGITS
OBJECT-TYPE    
  E164  

lmiNetSideTable 1.3.6.1.4.1.251.1.1.37.2
This table is used to configure and control network side ILMI.
OBJECT-TYPE    
  SEQUENCE OF  
    LmiNetSideEntry

lmiNetSideEntry 1.3.6.1.4.1.251.1.1.37.2.1
OBJECT-TYPE    
  LmiNetSideEntry  

lmiNetSideLinkNo 1.3.6.1.4.1.251.1.1.37.2.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

lmiNetSidePrefixId 1.3.6.1.4.1.251.1.1.37.2.1.2
Network prefix identification number.
OBJECT-TYPE    
  INTEGER 1..5  

lmiNetSidePrefix 1.3.6.1.4.1.251.1.1.37.2.1.3
Network prefix to register or de-register.
OBJECT-TYPE    
  E164SUB  

lmiNetSidePrefixStatus 1.3.6.1.4.1.251.1.1.37.2.1.4
Set to register to send the prefix to the user side; set to de-register to remove the prefix from the user side.
OBJECT-TYPE    
  INTEGER start-registration(1), start-deregistration(2), valid(3), invalid(4), registered(5), deregistered(6), time-out-failure(7), unknown(8), not-allowed(9), rejected(10)  

lmiUserSideTable 1.3.6.1.4.1.251.1.1.37.3
This table is used to configure and control user side ILMI.
OBJECT-TYPE    
  SEQUENCE OF  
    LmiUserSideEntry

lmiUserSideEntry 1.3.6.1.4.1.251.1.1.37.3.1
OBJECT-TYPE    
  LmiUserSideEntry  

lmiUserSideLinkNo 1.3.6.1.4.1.251.1.1.37.3.1.1
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 0..1  

lmiUserSideAddressId 1.3.6.1.4.1.251.1.1.37.3.1.2
The link number for this configuration.
OBJECT-TYPE    
  INTEGER 1..16  

lmiUserSideAddress 1.3.6.1.4.1.251.1.1.37.3.1.3
ATM address to register or de-register.
OBJECT-TYPE    
  E164SUB  

lmiUserSideAddressStatus 1.3.6.1.4.1.251.1.1.37.3.1.4
Set to valid to register the address to the network side; set to invalid to de-register the address from the network side.
OBJECT-TYPE    
  INTEGER start-registration(1), start-deregistration(2), valid(3), invalid(4), registered(5), deregistered(6), time-out-failure(7), unknown(8), not-allowed(9), rejected(10)  

dv2AlarmHandler 1.3.6.1.4.1.251.1.1.38
OBJECT IDENTIFIER    

alarmNodeCrit 1.3.6.1.4.1.251.1.1.38.1
Node Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

alarmNodeMajor 1.3.6.1.4.1.251.1.1.38.2
Node Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

alarmNodeMinor 1.3.6.1.4.1.251.1.1.38.3
Node Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

alarmStatTable 1.3.6.1.4.1.251.1.1.38.4
This table is used for Alarm Handler status
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmStatEntry

alarmStatEntry 1.3.6.1.4.1.251.1.1.38.4.1
OBJECT-TYPE    
  AlarmStatEntry  

alrStatSlotNo 1.3.6.1.4.1.251.1.1.38.4.1.1
Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

slotCritStatus 1.3.6.1.4.1.251.1.1.38.4.1.2
Slot Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

slotMajorStatus 1.3.6.1.4.1.251.1.1.38.4.1.3
Slot Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

slotMinorStatus 1.3.6.1.4.1.251.1.1.38.4.1.4
Slot Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

link0CritStatus 1.3.6.1.4.1.251.1.1.38.4.1.5
Link 0 Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

link0MajorStatus 1.3.6.1.4.1.251.1.1.38.4.1.6
Link 0 Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

link0MinorStatus 1.3.6.1.4.1.251.1.1.38.4.1.7
Link 0 Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

link1CritStatus 1.3.6.1.4.1.251.1.1.38.4.1.8
Link 1 Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

link1MajorStatus 1.3.6.1.4.1.251.1.1.38.4.1.9
Link 1 Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

link1MinorStatus 1.3.6.1.4.1.251.1.1.38.4.1.10
Link 1 Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

link2CritStatus 1.3.6.1.4.1.251.1.1.38.4.1.11
Link 2 Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

link2MajorStatus 1.3.6.1.4.1.251.1.1.38.4.1.12
Link 2 Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

link2MinorStatus 1.3.6.1.4.1.251.1.1.38.4.1.13
Link 2 Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

link3CritStatus 1.3.6.1.4.1.251.1.1.38.4.1.14
Link 3 Critical Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), crit(2), crit-aco(3)  

link3MajorStatus 1.3.6.1.4.1.251.1.1.38.4.1.15
Link 3 Major Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), maj(2), maj-aco(3)  

link3MinorStatus 1.3.6.1.4.1.251.1.1.38.4.1.16
Link 3 Minor Alarm Status
OBJECT-TYPE    
  INTEGER clr(1), min(2), min-aco(3)  

alarmNodeACO 1.3.6.1.4.1.251.1.1.38.5
Node ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alarmACOTable 1.3.6.1.4.1.251.1.1.38.6
This table is used for the Alarm Handler ACO
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmACOEntry

alarmACOEntry 1.3.6.1.4.1.251.1.1.38.6.1
OBJECT-TYPE    
  AlarmACOEntry  

alrACOslotNo 1.3.6.1.4.1.251.1.1.38.6.1.1
Slot Number
OBJECT-TYPE    
  INTEGER 0..15  

alrACOslotACO 1.3.6.1.4.1.251.1.1.38.6.1.2
Slot ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alrACOlink0ACO 1.3.6.1.4.1.251.1.1.38.6.1.3
Link 0 ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alrACOlink1ACO 1.3.6.1.4.1.251.1.1.38.6.1.4
Link 1 ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alrACOlink2ACO 1.3.6.1.4.1.251.1.1.38.6.1.5
Link 2 ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alrACOlink3ACO 1.3.6.1.4.1.251.1.1.38.6.1.6
Link 3 ACO Status
OBJECT-TYPE    
  INTEGER off(1), on(2)  

userStatusTable 1.3.6.1.4.1.251.1.1.38.7
This table is used for the User Status Inputs
OBJECT-TYPE    
  SEQUENCE OF  
    UserStatusEntry

userStatusEntry 1.3.6.1.4.1.251.1.1.38.7.1
OBJECT-TYPE    
  UserStatusEntry  

userInputNo 1.3.6.1.4.1.251.1.1.38.7.1.1
User Status Input Number
OBJECT-TYPE    
  INTEGER 0..1  

userInputEnable 1.3.6.1.4.1.251.1.1.38.7.1.2
Enable User Status Input
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), not-applicable(3)  

userInputTrapEnable 1.3.6.1.4.1.251.1.1.38.7.1.3
Enable User Defined Trap/Event
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

userInputTrapDesc 1.3.6.1.4.1.251.1.1.38.7.1.4
Description string for trap/event
OBJECT-TYPE    
  DisplayString  

userInputActiveState 1.3.6.1.4.1.251.1.1.38.7.1.5
Alarm active state of user input relay switch
OBJECT-TYPE    
  INTEGER active-closed(1), active-open(2)  

userInputAlrClass 1.3.6.1.4.1.251.1.1.38.7.1.10
Classification of Status/Alarm Input
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3), informational(4)  

userInputStatus 1.3.6.1.4.1.251.1.1.38.7.1.11
Current Status of Status/Alarm Input
OBJECT-TYPE    
  INTEGER clear(1), active(2)  

alarmScanFile 1.3.6.1.4.1.251.1.1.38.8
Rescan the alr_class.txt file
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

dv2Cac 1.3.6.1.4.1.251.1.1.39
OBJECT IDENTIFIER    

cacCurrentEbtId 1.3.6.1.4.1.251.1.1.39.1
Current EBT file ID code. cacCurrentEbtId holds the EBT file ID code of the EBT file currently in memory in a verified state. The CAC application is responsible for maintaining the state of this variable. If there is a verified EBT in memory cacCurrentEbtId will still hold the EBT file's ID code even if the CAC is disabled or the CAC version is scr-pcr. If there is no EBT in memory or the verification was unsuccessful then the value of cacCurrentEbtId is zero (0).
OBJECT-TYPE    
  INTEGER 0..65535  

cacEbtCommand 1.3.6.1.4.1.251.1.1.39.2
EBT file command. This field, normally with the value none, may be set by the manager to: * load-ebt to initiate the loading of a new EBT file into memory. * dump-ebt to initiate the dump of the EBT memory content into flash. * delete-ebt to cause an EBT file to be deleted in the flash. The value of cacEbtCommand will return to none when the EBT file command has been completed.
OBJECT-TYPE    
  INTEGER none(1), load-EBT(2), dump-EBT(3), delete-EBT(4)  

cacCommandEbtId 1.3.6.1.4.1.251.1.1.39.3
Command EBT file ID code. cacCommandEbtId is written to by the manager to identify the EBT file in the flash that should be loaded or deleted. When the cacEbtCommand MIB item is set to either load-ebt or delete-ebt, the CAC software attempts to load or delete the EBT file named ebXXXXX.bin from flash, where XXXXX is the value cacCommandEbtId padded to five digits with leading zeros. The value zero (0) is not a valid EBT file ID code and is reserved to indicate that EBT file ID code has not been specified.
OBJECT-TYPE    
  INTEGER 0..65535  

cacEbtState 1.3.6.1.4.1.251.1.1.39.4
State of the CAC. The state: * uninitialized is an initial MIB value which is never returned to without starting from a new MIB. * initializing indicates the initial part of the CAC boot. * loading indicates that an EBT file is being loaded. * ready indicates that a valid EBT is in memory. In this state the current EBT file ID code shows the ID code of the EBT in memory. * unusable is reached after an unsuccessful load and indicates that the data in the EBT memory block is unusable (in this state current EBT file ID code shows 0).
OBJECT-TYPE    
  INTEGER uninitialized(1), initializing(2), loading(3), ready(4), unusable(5)  

cacErrorCode 1.3.6.1.4.1.251.1.1.39.5
Error code. Error codes are produced at certain stages in the CAC application. The interpretation of the error codes is: Terms: 'ebXXXXX.bin' : binary file in flash data structure: EBT_file_template based structure * no-error: no error encountered. * nonexistent-file: the 'ebXXXXX.bin' file not found in the flash, during APEX boot or MIB EBT load request. * bad-file-length: mismatch in file length specified within 'ebXXXXX.bin' and the pre-specified file length. Occurs while loading file into data structures. * copy-corrupted: copying of data from 'ebXXXXX.bin' into the data structure, EBT_file_template did not proceed smoothly and the data structure is now corrupted. * nunused-cbtdwoEBTid: command EBT id not used and current EBT id is 0. The CAC booted without valid EBT values in the data structure. Occurs during boot while loading file into data structures. * nunused-cinvalid: command EBT id not used. The file eb'current EBT id'.bin contains invalid data. Occurs just after the EBT file got loaded into the data structure, when the verification of values in the data structure takes place. * nEBTid-uninit-cstays: command EBT id is 0 and the data structures remain unchanged. Occurs when mib item cacTableload is switched to yes. * ninvalid-cstays: eb'command EBT id'.bin contains invalid data and the data structures remain unchanged. Occurs when mib item cacTableload is switched to yes. * ninvalid-cEBTid-uninit: eb'command EBT id'.bin contains invalid data and the current EBT id is zero. This means that data structure is corrupted. Occurs when mib item cacTableload is switched to yes. * ninvalid-cinvalid: both eb'command EBT id'.bin and eb'current EBT id'.bin contains invalid data. The data structure is corrupted. Occurs when mib item cacTableload is switched to yes. * ninvalid-cnoerror: eb'command EBT id'.bin contains invalid data and the eb'current EBT id'.bin is loaded successfully. Occurs when mib item cacTableload is switched to yes. * link-not-ready: it is a runtime error which states that link is not ready for configuration. * link-not-configuring: it is a runtime error which states that link is not in configuring mode and therefore the recalculation of EBT or scr-pcr sums is not possible. * EBT-not-loaded: it is a runtime error which states that the data structure does not contain valid data. This occurs when the EBT enable mib switch is turned to 'yes' or the cac version mib item is switched to EBT. * class-not-found: this runtime error indicates that during the processing of allocate, deallocate or change functions, a class corresponding to SCR, PCR or MBS was not found. The effective bandwidth used in this situation is the same as a CBR allocation using the attempted connection's PCR. * dump-fs-error: this error indicates that a file system error (e.g. the file system became full) during the EBT file dump function. The dump file was deleted after the file system error was detected.
OBJECT-TYPE    
  INTEGER no-error(1), nonexistent-file(2), bad-file-length(3), copy-corrupted(4), nunused-cbtdwoebtid(5), nunused-cinvalid(6), nebtid-uninit-cstays(7), ninvalid-cstays(8), ninvalid-cebtid-uninit(9), ninvalid-cinvalid(10), ninvalid-cnoerror(11), link-not-ready(12), link-not-configuring(13), ebt-not-loaded(14), class-not-found(15), dump-fs-error(16), bad-ebt-command(17), delete-fs-error(18), ebt-id-invalid(19)  

cacPerLinkTable 1.3.6.1.4.1.251.1.1.39.6
This table containing per link data. Contains per link specific data
OBJECT-TYPE    
  SEQUENCE OF  
    CacPerLinkEntry

cacPerLinkEntry 1.3.6.1.4.1.251.1.1.39.6.1
OBJECT-TYPE    
  CacPerLinkEntry  

cacLinkNo 1.3.6.1.4.1.251.1.1.39.6.1.1
Link number. cacLinkNo is the index (0..3) to the array of link data.
OBJECT-TYPE    
  INTEGER 0..3  

cacLinkSumE10 1.3.6.1.4.1.251.1.1.39.6.1.2
Running sum of e10. cacSumE10 zero loss effective bandwidth for high priority queue. This value is maintained only when the CAC is enabled on the link (cacEnable) and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacLinkSumE1T 1.3.6.1.4.1.251.1.1.39.6.1.3
Running sum of e1T. cacSumE1T tangent effective bandwidth for high priority queue. This value is maintained only when the CAC is enabled on the link (cacEnable) and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacLinkObfPvc1 1.3.6.1.4.1.251.1.1.39.6.1.4
Utilization factor for high priority pvc. Utilization factor for PVCs and SPVCs for the high priority queue.
OBJECT-TYPE    
  INTEGER  

cacLinkObfSvc1 1.3.6.1.4.1.251.1.1.39.6.1.5
Utilization factor for high priority svc. Utilization factor for SVCs for the high priority queue.
OBJECT-TYPE    
  INTEGER  

cacLinkSumE20 1.3.6.1.4.1.251.1.1.39.6.1.6
Running sum of e20. cacSumE20 zero loss effective bandwidth for low priority queue. This value is maintained only when the CAC is enabled on the link (cacEnable) and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacLinkSumE2T 1.3.6.1.4.1.251.1.1.39.6.1.7
Running sum of e2T. cacSumE1T zero tangent effective bandwidth for low priority queue. This value is maintained only when the CAC is enabled on the link (cacEnable) and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacLinkObfPvc2 1.3.6.1.4.1.251.1.1.39.6.1.8
Utilization factor for low priority pvc. Utilization factor for PVCs and SPVCs for the low priority queue.
OBJECT-TYPE    
  INTEGER  

cacLinkObfSvc2 1.3.6.1.4.1.251.1.1.39.6.1.9
Utilization factor for low priority svc. Utilization factor for SVCs for the low priority queue.
OBJECT-TYPE    
  INTEGER  

cacLinkTotalBwScrPcr 1.3.6.1.4.1.251.1.1.39.6.1.10
total bw allocation on the link by scr-pcr CAC. cacTotalBwScrPcr is the total bandwidth allocated to extant connections when the CAC is enabled and when the SCR-PCR CAC is being used. Its value is zero if CAC is disabled or the EBT CAC mode is used.
OBJECT-TYPE    
  INTEGER  

cacCurrentLinkUsage 1.3.6.1.4.1.251.1.1.39.6.1.11
Current link bandwidth allocation. It is the current indication of bandwidth allocation on a link based on the formula using effective bandwidths
OBJECT-TYPE    
  INTEGER  

cacMaxLinkUsage 1.3.6.1.4.1.251.1.1.39.6.1.12
Max link bw allocation since last reset or card boot. cacMaxLinkUsage shows the maximum value that cacCurrentLinkUsage has reached since cacMaxLinkUsage was last reset.
OBJECT-TYPE    
  INTEGER  

cacLinkReset 1.3.6.1.4.1.251.1.1.39.6.1.13
Reload maximum link usage from current allocation. cacReset resets cacMaxLinkUsage, after the reset cacMaxLinkUsage shows the same value as cacCurrentLinkUsage.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cacLinkVersion 1.3.6.1.4.1.251.1.1.39.6.1.14
Use EB CAC or scr-pcr CAC? The per-link variable cacVersion may take on the values * SCR-PCR indicating that the old, pre Rel 4.2 CAC based on SCR and PCR values, is in operation or * EBT indicating that the new CAC based on effective bandwidths is used. cacVersion may be set by the manager. If cacVersion is set to EBT by the manager it will revert to SCR-PCR unless a valid EBT is currently available in memory (in which case cacEbtState==ready and cacCurrentEbtId holds a non-zero value). The cacVersion may also revert to SCR-PCR if, during boot or an EBT load, a valid EBT cannot be established in memory. A change of state in cacVersion will result in recalculatation of EB Sums.
OBJECT-TYPE    
  INTEGER ebt(1), scr-pcr(2)  

cacLinkEnable 1.3.6.1.4.1.251.1.1.39.6.1.15
Enable cac? When cacEnable has the value * yes, then the three CAC service routines are operational as defined, * no, then all connections are accepted regardless of required bandwidths CAC may be enabled or disabled by the manager at any time that the cacLinkState is ready. Enabling CAC will cause recalculatation of EB sums for that link. Disabling CAC will cause the EB sums for the link (also for associated V-SAPs) to be set to zero.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cacLinkSignalMode 1.3.6.1.4.1.251.1.1.39.6.1.16
Link signalling mode cacSignallingMode is a read-only variable indicating whether the link is currently in the signalling mode: * single-channel or * multi-channel The value of cacSignallingMode is updated any time a virtual SAP is either associated or disassociated with a physical SAP. Multi-channel mode indicates that at least one virtual SAP is associated with the link's physical SAP. In multi-channel mode the zero-loss effective bandwidths are not used for connection admission control.
OBJECT-TYPE    
  INTEGER single-channel(1), multi-channel(2)  

cacLinkState 1.3.6.1.4.1.251.1.1.39.6.1.17
State of the Link The cacLinkState variable can take the values: * uninitialised is an initial MIB value which is never returned to without staring from a new MIB. * configuring indicates that the CAC on that link cannot be used at the current time. This indicates that CAC is booting, an EBT is being loaded. This is a transient state that will go to ready or recalculating. * recalculating indicates that the sums for both eb and scr-pcr are cleared and are recalculated for the existing connections. * ready indicates that CAC may be used on that link. The state machine is given in Figure 3. Transitions out of the ready state can be caused by a boot, an EBT load or the call back functions on (per link) Enable and Version. Whether the transition from configuring back to ready is direct or via recalculating depends on whether or not there is a need to recalculate the effective bandwidth sums; this depends on several factors that can be derived from the detailed design in Section 6.2.4.7. The value of the cacLinkState variable is valid and indicates the current link state of the CAC indepenently of the value of cacEnable, cacVersion and cacEbtState. When cacLinkState is configuring, certain CAC functions are disabled: * Requests to the allocate, deallocate and allocation_change service routines will be rejected without processing. * Requests to the allocation summary routine may produce inconsistent results. When cacLinkState is recalculating, certain CAC functions are disabled: * Requests to allocation_change and deallocate service routines will be rejected without processing. * Requests to the allocation summary routine may produce inconsistent results.
OBJECT-TYPE    
  INTEGER uninitialized(1), configuring(2), recalculating(3), ready(4)  

cacPerSapTable 1.3.6.1.4.1.251.1.1.39.7
This table containing per Sap data. The virtual SAP table in the MIB has 12 entries indexed by cacSapNo in the range (20..31). For each SAP there the table entries are detailed below. These entries are only used when at least one of the link's cacSignallingMode is multi-channel. The association of a virtual SAP to a link is given in the resource table MIB group.
OBJECT-TYPE    
  SEQUENCE OF  
    CacPerSapEntry

cacPerSapEntry 1.3.6.1.4.1.251.1.1.39.7.1
OBJECT-TYPE    
  CacPerSapEntry  

cacSapNo 1.3.6.1.4.1.251.1.1.39.7.1.1
SAP number. cacSapNo is the index (0..11) to the array of sap data.
OBJECT-TYPE    
  INTEGER 20..31  

cacSapSumE1T 1.3.6.1.4.1.251.1.1.39.7.1.2
Running sum of e1T. cacSumE1T tangent effective bandwidth for high priority queue These values are maintained only when the CAC is enabled on the link (cacEnable), when the SAP is assigned to a link and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacSapSumE2T 1.3.6.1.4.1.251.1.1.39.7.1.3
Running sum of e2T. cacSumE1T tangent effective bandwidth for low priority queue These values are maintained only when the CAC is enabled on the link (cacEnable), when the SAP is assigned to a link and when the EBT CAC version is being used (cacVersion==EBT) otherwise the values here are zero.
OBJECT-TYPE    
  Gauge  

cacSapTotalBwScrPcr 1.3.6.1.4.1.251.1.1.39.7.1.4
total bw allocation on the link by scr-pcr CAC. cacTotalBwScrPcr is the total bandwidth allocated to extant connections when the CAC is enabled and when the SCR-PCR CAC is being used. Its value is zero if CAC is disabled or the EBT CAC mode is used.
OBJECT-TYPE    
  INTEGER  

cacCurrentSapUsage 1.3.6.1.4.1.251.1.1.39.7.1.5
Current SAP bandwidth allocation It is the current indication of bandwidth allocation on a sap based on the formula using effective bandwidths.
OBJECT-TYPE    
  INTEGER  

cacMaxSapUsage 1.3.6.1.4.1.251.1.1.39.7.1.6
Max SAP b/w allocation since last reset or card boot. cacMaxSapUsage shows the maximum value that cacCurrentSapUsage has reached since cacMaxSapUsage was last reset.
OBJECT-TYPE    
  INTEGER  

cacSapReset 1.3.6.1.4.1.251.1.1.39.7.1.7
Reload maximum SAP usage from current allocation cacReset resets cacMaxSapUsage, after the reset cacMaxSapUsage shows the same value as cacCurrentSapUsage.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dv2MS2FRAC 1.3.6.1.4.1.251.1.1.40
OBJECT IDENTIFIER    

dv2aal5 1.3.6.1.4.1.251.1.1.41
OBJECT IDENTIFIER    

vhsystem 1.3.6.1.4.1.251.1.1.42
OBJECT IDENTIFIER    

limHostRev 1.3.6.1.4.1.251.1.1.42.1
Host S/W Revision
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

limBootRev 1.3.6.1.4.1.251.1.1.42.2
Boot S/W Revision
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

limHwRev 1.3.6.1.4.1.251.1.1.42.3
Hardware Architecture
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

limAction 1.3.6.1.4.1.251.1.1.42.4
LIM action
OBJECT-TYPE    
  INTEGER none(1), reset(2), test(3), mtce(4)  

limState 1.3.6.1.4.1.251.1.1.42.5
LIM state
OBJECT-TYPE    
  INTEGER init(1), testing(2), idle(3), start(4), working(5), terminate(6), fault(7), mtce(8), loading(9), await-framing(10)  

limFault 1.3.6.1.4.1.251.1.1.42.6
LIM Fault LED
OBJECT-TYPE    
  INTEGER off(1), on(2)  

limFaultReason 1.3.6.1.4.1.251.1.1.42.7
LIM Fault Reason
OBJECT-TYPE    
  INTEGER none(1), bad-rev(2), hw-fault(3), memory(4), fileio(5), codec-section(6), sw-error(7)  

limCodec0 1.3.6.1.4.1.251.1.1.42.8
H.320 Codec 0 Active LED
OBJECT-TYPE    
  INTEGER off(1), on(2)  

limCodec1 1.3.6.1.4.1.251.1.1.42.9
H.320 Codec 1 Active LED
OBJECT-TYPE    
  INTEGER off(1), on(2)  

limSCmgmt 1.3.6.1.4.1.251.1.1.42.10
Slot Controller Mgmt Link Status
OBJECT-TYPE    
  INTEGER up(1), down(2)  

limSCmgmtData 1.3.6.1.4.1.251.1.1.42.11
Slot Controller Mgmt Information Data State
OBJECT-TYPE    
  INTEGER idle(1), start(2), continue(3), end(4), ack(5), aborted(6), error(7)  

limSCfileXferReq 1.3.6.1.4.1.251.1.1.42.12
Slot Controller Mgmt File Transfer Request
OBJECT-TYPE    
  INTEGER none(1), vh320-cod(2), vhdev-cod(3)  

limSCfileXferStat 1.3.6.1.4.1.251.1.1.42.13
Slot Controller Mgmt File Transfer State
OBJECT-TYPE    
  INTEGER idle(1), start(2), continue(3), end(4), ack(5), aborted(6), error(7)  

limSCbytes 1.3.6.1.4.1.251.1.1.42.14
Slot Controller Mgmt File Transfer Byte Count
OBJECT-TYPE    
  INTEGER  

vhcontrol 1.3.6.1.4.1.251.1.1.43
OBJECT IDENTIFIER    

ctrlTable 1.3.6.1.4.1.251.1.1.43.1
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlEntry

ctrlEntry 1.3.6.1.4.1.251.1.1.43.1.1
OBJECT-TYPE    
  CtrlEntry  

ctrlIndex 1.3.6.1.4.1.251.1.1.43.1.1.1
Codec Index
OBJECT-TYPE    
  INTEGER 0..1  

ctrlCodecType 1.3.6.1.4.1.251.1.1.43.1.1.2
Codec Type
OBJECT-TYPE    
  INTEGER h320(1)  

ctrlCodecAction 1.3.6.1.4.1.251.1.1.43.1.1.3
Codec Action
OBJECT-TYPE    
  INTEGER none(1), reset(2), test(3), mtce(4)  

ctrlCodecReq 1.3.6.1.4.1.251.1.1.43.1.1.4
Codec Request
OBJECT-TYPE    
  INTEGER connect(1), disconnect(2)  

ctrlCallType 1.3.6.1.4.1.251.1.1.43.1.1.5
Codec Call Type
OBJECT-TYPE    
  INTEGER h0(1)  

ctrlCodecSta 1.3.6.1.4.1.251.1.1.43.1.1.6
Codec Status
OBJECT-TYPE    
  INTEGER init(1), testing(2), idle(3), start(4), working(5), terminate(6), fault(7), mtce(8), loading(9), await-framing(10)  

ctrlChnlLpbk 1.3.6.1.4.1.251.1.1.43.1.1.7
Codec Channel Loopback
OBJECT-TYPE    
  INTEGER none(1), to-other(2), to-self(3)  

ctrlFraming 1.3.6.1.4.1.251.1.1.43.1.1.8
Codec H.221 Framing Detected
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ctrlChnlStat 1.3.6.1.4.1.251.1.1.43.1.1.9
Codec Channel Link Status
OBJECT-TYPE    
  INTEGER down(1), idle(2), up(3), loopback(4)  

ctrlFaultReason 1.3.6.1.4.1.251.1.1.43.1.1.10
Codec Fault Reason
OBJECT-TYPE    
  INTEGER none(1), host(2), video(3), audio(4), data(5), fileio(6), mem(7), h221(8), h242(9), tdm(10)  

vidTable 1.3.6.1.4.1.251.1.1.43.2
OBJECT-TYPE    
  SEQUENCE OF  
    VidEntry

vidEntry 1.3.6.1.4.1.251.1.1.43.2.1
OBJECT-TYPE    
  VidEntry  

vidIndex 1.3.6.1.4.1.251.1.1.43.2.1.1
VH320 Codec Index
OBJECT-TYPE    
  INTEGER 0..1  

vidStandard 1.3.6.1.4.1.251.1.1.43.2.1.2
VH320 Analog Video I/O Standard
OBJECT-TYPE    
  INTEGER ntsc(1), pal(2)  

vidTxVidReq 1.3.6.1.4.1.251.1.1.43.2.1.3
VH320 Transmit Video Request
OBJECT-TYPE    
  INTEGER normal(1), freeze(2), mute(3)  

vidRxVidReq 1.3.6.1.4.1.251.1.1.43.2.1.4
VH320 Display Video Request
OBJECT-TYPE    
  INTEGER normal(1), freeze(2), mute(3)  

vidViewPip 1.3.6.1.4.1.251.1.1.43.2.1.5
VH320 View Self Picture in Picture
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vidCompQual 1.3.6.1.4.1.251.1.1.43.2.1.6
VH320 Compression Quality
OBJECT-TYPE    
  INTEGER best-picture(1), best-motion(2)  

vidDigLpbk 1.3.6.1.4.1.251.1.1.43.2.1.7
VH320 Digital Loopback
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vidEncFrameCount 1.3.6.1.4.1.251.1.1.43.2.1.8
VH320 Video Encoded Frame Count
OBJECT-TYPE    
  Counter  

vidDecFrameCount 1.3.6.1.4.1.251.1.1.43.2.1.9
VH320 Video Decoded Frame Count
OBJECT-TYPE    
  Counter  

vidState 1.3.6.1.4.1.251.1.1.43.2.1.10
VH320 Video State
OBJECT-TYPE    
  INTEGER init(1), diag(2), idle(3), start(4), working(5), terminate(6), fault(7)  

vidInPresent 1.3.6.1.4.1.251.1.1.43.2.1.11
VH320 Video Input Present
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vidEncBitRate 1.3.6.1.4.1.251.1.1.43.2.1.12
VH320 Encoded Bitrate (bps)
OBJECT-TYPE    
  INTEGER  

audTable 1.3.6.1.4.1.251.1.1.43.3
OBJECT-TYPE    
  SEQUENCE OF  
    AudEntry

audEntry 1.3.6.1.4.1.251.1.1.43.3.1
OBJECT-TYPE    
  AudEntry  

audIndex 1.3.6.1.4.1.251.1.1.43.3.1.1
VH320 Codec Index
OBJECT-TYPE    
  INTEGER 0..1  

audState 1.3.6.1.4.1.251.1.1.43.3.1.2
VH320 Audio State
OBJECT-TYPE    
  INTEGER init(1), testing(2), idle(3), start(4), working(5), terminate(6), fault(7), mtce(8), loading(9), await-framing(10)  

audPrefMode 1.3.6.1.4.1.251.1.1.43.3.1.3
VH320 Audio Preferred Coding Mode
OBJECT-TYPE    
  INTEGER u-law(1), a-law(2), g722(3), g728(4)  

audCommMode 1.3.6.1.4.1.251.1.1.43.3.1.4
VH320 Audio Common Coding Mode
OBJECT-TYPE    
  INTEGER u-law(1), a-law(2), g722(3), g728(4)  

audBitRate 1.3.6.1.4.1.251.1.1.43.3.1.5
VH320 Audio Bit Rate (bps)
OBJECT-TYPE    
  INTEGER  

audMuteInReq 1.3.6.1.4.1.251.1.1.43.3.1.6
VH320 Audio Mute Input Request
OBJECT-TYPE    
  INTEGER off(1), on(2)  

audMuteOutReq 1.3.6.1.4.1.251.1.1.43.3.1.7
VH320 Audio Mute Output Request
OBJECT-TYPE    
  INTEGER off(1), on(2)  

audMuteOutStat 1.3.6.1.4.1.251.1.1.43.3.1.8
VH320 Audio Mute Output Status
OBJECT-TYPE    
  INTEGER off(1), on(2), auto(3)  

audLpbk 1.3.6.1.4.1.251.1.1.43.3.1.9
VH320 Audio Loopback Request
OBJECT-TYPE    
  INTEGER none(1), analog-in(2), digital-in(3), compress-in(4), analog-out(5), digital-out(6), compress-out(7)  

audInVol 1.3.6.1.4.1.251.1.1.43.3.1.10
VH320 Audio Input Volume
OBJECT-TYPE    
  INTEGER 0..255  

audOutVol 1.3.6.1.4.1.251.1.1.43.3.1.11
VH320 Audio Output Volume
OBJECT-TYPE    
  INTEGER 0..255  

audInDelay 1.3.6.1.4.1.251.1.1.43.3.1.12
VH320 Audio Input Delay Request (ms)
OBJECT-TYPE    
  INTEGER 0..200  

audOutDelay 1.3.6.1.4.1.251.1.1.43.3.1.13
VH320 Audio Output Delay Status (ms)
OBJECT-TYPE    
  INTEGER 0..200  

audFaultReason 1.3.6.1.4.1.251.1.1.43.3.1.14
VH320 Audio Fault Reason
OBJECT-TYPE    
  INTEGER none(1), mem(2), self-test(3), download(4), loopback(5), dsp(6)  

dataTable 1.3.6.1.4.1.251.1.1.43.4
OBJECT-TYPE    
  SEQUENCE OF  
    DataEntry

dataEntry 1.3.6.1.4.1.251.1.1.43.4.1
OBJECT-TYPE    
  DataEntry  

dataIndex 1.3.6.1.4.1.251.1.1.43.4.1.1
VH320 Codec Index
OBJECT-TYPE    
  INTEGER 0..1  

dataChnlType 1.3.6.1.4.1.251.1.1.43.4.1.2
Data Channel Type
OBJECT-TYPE    
  INTEGER lsd(1), hsd(2), mlp(3), hmlp(4), none(5)  

dataPortSpeed 1.3.6.1.4.1.251.1.1.43.4.1.3
Data Port Speed (bps)
OBJECT-TYPE    
  INTEGER baud-2400(1), baud-9600(2), baud-19200(3), baud-38400(4)  

dataPortProt 1.3.6.1.4.1.251.1.1.43.4.1.4
Data Port Protocol
OBJECT-TYPE    
  INTEGER async(1), hdlc(2)  

dataHDLCcheck 1.3.6.1.4.1.251.1.1.43.4.1.5
HDLC Check CRC
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

dataChnlStat 1.3.6.1.4.1.251.1.1.43.4.1.6
Data Channel Status
OBJECT-TYPE    
  INTEGER up(1), down(2)  

dataBytesRcvd 1.3.6.1.4.1.251.1.1.43.4.1.7
Data Channel Bytes Received
OBJECT-TYPE    
  Counter  

dataBytesSent 1.3.6.1.4.1.251.1.1.43.4.1.8
Data Channel Bytes Sent
OBJECT-TYPE    
  Counter  

dataResetStat 1.3.6.1.4.1.251.1.1.43.4.1.9
Data Channel Reset Statistics
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vhmgmt 1.3.6.1.4.1.251.1.1.44
OBJECT IDENTIFIER    

mgmtTable 1.3.6.1.4.1.251.1.1.44.1
OBJECT-TYPE    
  SEQUENCE OF  
    MgmtEntry

mgmtEntry 1.3.6.1.4.1.251.1.1.44.1.1
OBJECT-TYPE    
  MgmtEntry  

mgmtIndex 1.3.6.1.4.1.251.1.1.44.1.1.1
VH320 Management Port Index
OBJECT-TYPE    
  INTEGER 0..1  

mgmtDescr 1.3.6.1.4.1.251.1.1.44.1.1.2
VH320 Management Port Descriptor
OBJECT-TYPE    
  DisplayString  

mgmtPortProt 1.3.6.1.4.1.251.1.1.44.1.1.3
Management Port Protocol
OBJECT-TYPE    
  INTEGER async(1), slip(2)  

mgmtPortSpeed 1.3.6.1.4.1.251.1.1.44.1.1.4
Management Port Speed (bps)
OBJECT-TYPE    
  INTEGER serial-200(1), baud-2400(2), baud-9600(3), baud-19200(4), baud-38400(5)  

mgmtPortAddress 1.3.6.1.4.1.251.1.1.44.1.1.5
Management Port Address
OBJECT-TYPE    
  IpAddress  

mgmtAddressMask 1.3.6.1.4.1.251.1.1.44.1.1.6
Management Port Address Mask
OBJECT-TYPE    
  IpAddress  

mgmtRemoteAddress 1.3.6.1.4.1.251.1.1.44.1.1.7
Management Remote Address
OBJECT-TYPE    
  IpAddress  

mgmtPortStat 1.3.6.1.4.1.251.1.1.44.1.1.8
Management Port Status
OBJECT-TYPE    
  INTEGER up(1), down(2)  

mgmtBytesRcvd 1.3.6.1.4.1.251.1.1.44.1.1.9
Management Bytes Received
OBJECT-TYPE    
  Counter  

mgmtBytesSent 1.3.6.1.4.1.251.1.1.44.1.1.10
Management Bytes Sent
OBJECT-TYPE    
  Counter  

mgmtResetStat 1.3.6.1.4.1.251.1.1.44.1.1.11
Management Reset Statistics
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

mainInServ 1.3.6.1.4.1.251.1.1.76
This is sent when the Main Slot 0 Controller goes into service
TRAP-TYPE    
  sysLastTrapMessage  
  slot0InUse  

standbyInServ 1.3.6.1.4.1.251.1.1.77
This is sent when the Standby Slot 0 Controller goes into service
TRAP-TYPE    
  sysLastTrapMessage  
  slot0InUse  

bill25pstfull 1.3.6.1.4.1.251.1.1.78
This is sent when billing table is 25% full.
TRAP-TYPE    
  billAvailable  

bill75pstfull 1.3.6.1.4.1.251.1.1.79
This is sent when billing table is 75% full.
TRAP-TYPE    
  billAvailable  

restart040 1.3.6.1.4.1.251.1.1.80
This is sent when the master processor has been restarted by the 68302 processor.
TRAP-TYPE    
  slotNumber  

alcTxError 1.3.6.1.4.1.251.1.1.81
This is sent after master processor has been reset due to ALC-87 Transmitter Error.
TRAP-TYPE    
  slotNumber  

lim-fault 1.3.6.1.4.1.251.1.1.91
Configured LIM type does not match the LIM in slot
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  limTypeStatus  

lim-oper 1.3.6.1.4.1.251.1.1.92
LIM operational
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  limTypeStatus  

psuAbsent 1.3.6.1.4.1.251.1.1.93
PSU Absent detected
TRAP-TYPE    
  sysLastTrapMessage  
  slot0PsuIndex  

psuPresent 1.3.6.1.4.1.251.1.1.94
PSU Presence detected
TRAP-TYPE    
  sysLastTrapMessage  
  slot0PsuIndex  

switchFabricSwap 1.3.6.1.4.1.251.1.1.95
Switch Fabric Redundant Swap
TRAP-TYPE    
  sysLastTrapMessage  

internalReset 1.3.6.1.4.1.251.1.1.106
This is sent after the software has detected an internal error and restarted itself.
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  

aal1Fault 1.3.6.1.4.1.251.1.1.107
This is sent when an AAL1 fault has occurred.
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

aal1Clear 1.3.6.1.4.1.251.1.1.108
This is sent when an AAL1 fault has been cleared.
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

ds1LOS 1.3.6.1.4.1.251.1.1.109
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1LOSAlarm  

ds1LOF 1.3.6.1.4.1.251.1.1.110
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1LOFAlarm  

ds1AIS 1.3.6.1.4.1.251.1.1.111
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1AISAlarm  

ds1Yellow 1.3.6.1.4.1.251.1.1.112
Yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1YellowAlarm  

ds1ExBER 1.3.6.1.4.1.251.1.1.113
Excessive Bit Error Rate Alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1ExBERAlarm  

ds1v2LOS 1.3.6.1.4.1.251.1.1.114
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1V2LOSAlarm  

ds1v2LOF 1.3.6.1.4.1.251.1.1.115
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1V2LOFAlarm  

ds1v2AIS 1.3.6.1.4.1.251.1.1.116
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1V2AISAlarm  

ds1v2Yellow 1.3.6.1.4.1.251.1.1.117
Yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1V2FerfAlarm  

ds1v2ExBER 1.3.6.1.4.1.251.1.1.118
Excessive Bit Error Rate Alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds1V2BERAlarm  

ds3LOS 1.3.6.1.4.1.251.1.1.119
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds3LOSAlarm  

ds3V2LOS 1.3.6.1.4.1.251.1.1.120
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  ds3V2LOSAlarm  

ds3LOF 1.3.6.1.4.1.251.1.1.121
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhDS3LOFAlarm  

ds3AIS 1.3.6.1.4.1.251.1.1.122
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhDS3AISAlarm  

ds3Yellow 1.3.6.1.4.1.251.1.1.123
Yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhDS3YellowAlarm  

ds3ExBER 1.3.6.1.4.1.251.1.1.124
Excessive Bit Error Rate Alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhDS3ExBERAlarm  

ds3FEFrmrDif 1.3.6.1.4.1.251.1.1.125
Received frame format is different than configured frame format
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhDS3RxFrmFmt  

e1LOS 1.3.6.1.4.1.251.1.1.126
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e1LOSAlarm  

e1LOF 1.3.6.1.4.1.251.1.1.127
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e1LOFAlarm  

e1AIS 1.3.6.1.4.1.251.1.1.128
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e1AISAlarm  

e1Yellow 1.3.6.1.4.1.251.1.1.129
Yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e1FerfAlarm  

e1ExBER 1.3.6.1.4.1.251.1.1.130
Excessive Bit Error Rate Alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e1ExBERAlarm  

e3LOS 1.3.6.1.4.1.251.1.1.131
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  e3LOSAlarm  

e3LOF 1.3.6.1.4.1.251.1.1.132
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhE3LOFAlarm  

e3AIS 1.3.6.1.4.1.251.1.1.133
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhE3AISAlarm  

e3Yellow 1.3.6.1.4.1.251.1.1.134
Yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhE3FERFAlarm  

e3ExBER 1.3.6.1.4.1.251.1.1.135
Excessive Bit Error Rate Alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhE3ExBERAlarm  

locd 1.3.6.1.4.1.251.1.1.136
Loss Of Cell Delineation
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhPLCPLOCDAlarm  

plcpYellow 1.3.6.1.4.1.251.1.1.137
PLCP yellow alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhPLCPYellowAlarm  

plcpLOF 1.3.6.1.4.1.251.1.1.138
PLCP Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  pdhPLCPLOFAlarm  

sdhLOS 1.3.6.1.4.1.251.1.1.139
SONET/SDH Loss of Signal
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmLOS  

sdhLOF 1.3.6.1.4.1.251.1.1.140
SONET/SDH Loss of Frame
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmLOF  

sdhLineAIS 1.3.6.1.4.1.251.1.1.141
SONET/SDH Line AIS failure
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmLineAIS  

sdhPathAIS 1.3.6.1.4.1.251.1.1.142
SONET/SDH Path AIS failure
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmPathAIS  

sdhLOP 1.3.6.1.4.1.251.1.1.143
SONET/SDH Loss of Pointer
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmLOP  

sdhPLM 1.3.6.1.4.1.251.1.1.144
SONET/SDH Path Label Mismatch
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmPLM  

sdhLineYellow 1.3.6.1.4.1.251.1.1.145
SONET/SDH Line FERF failure
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmLineRFI  

sdhPathYellow 1.3.6.1.4.1.251.1.1.146
SONET/SDH Path Yellow failure
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSAlarmPathRFI  

sdhExBER 1.3.6.1.4.1.251.1.1.147
SONET/SDH Excessive Bit Error Rate
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  sdhSExBERAlarm  

clockActiveRef 1.3.6.1.4.1.251.1.1.148
Current Active Reference
TRAP-TYPE    
  inService  

outOfResource 1.3.6.1.4.1.251.1.1.149
Link cell rate is not sufficient for established connections
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

hssiLOS 1.3.6.1.4.1.251.1.1.150
HSSI Loss of Signal
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  hssiLOSAlarm  

hssiDTEReady 1.3.6.1.4.1.251.1.1.151
DTE is Ready
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

hssiDCEReady 1.3.6.1.4.1.251.1.1.152
DCE is Ready
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

hssiDTENotReady 1.3.6.1.4.1.251.1.1.153
DTE is not Ready
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

hssiDCENotReady 1.3.6.1.4.1.251.1.1.154
DCE is not Ready
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  

userstatus1 1.3.6.1.4.1.251.1.1.155
TRAP-TYPE    
  sysLastTrapMessage  
  userInputStatus  

userstatus2 1.3.6.1.4.1.251.1.1.156
TRAP-TYPE    
  sysLastTrapMessage  
  userInputStatus  

pntmoper 1.3.6.1.4.1.251.1.1.157
Sent when Primary NTM card operational status changes
TRAP-TYPE    
  sysLastTrapMessage  
  pscatmode  

sntmoper 1.3.6.1.4.1.251.1.1.158
Sent when Secondary NTM card operational status changes
TRAP-TYPE    
  sysLastTrapMessage  
  sscatmode  

pntmoscstatus 1.3.6.1.4.1.251.1.1.159
Sent when Primary NTM card oscillator status changes
TRAP-TYPE    
  sysLastTrapMessage  
  pcatstr3oscstatus  

sntmoscstatus 1.3.6.1.4.1.251.1.1.160
Sent when secondary NTM card oscillator status changes
TRAP-TYPE    
  sysLastTrapMessage  
  scatstr3oscstatus  

pbitslineok 1.3.6.1.4.1.251.1.1.161
Sent when Primary NTM card BITS line status changes
TRAP-TYPE    
  sysLastTrapMessage  
  pbslineok  

sbitslineok 1.3.6.1.4.1.251.1.1.162
Sent when secondary NTM card BITS line status changes
TRAP-TYPE    
  sysLastTrapMessage  
  sbslineok  

svcHalfConnect 1.3.6.1.4.1.251.1.1.163
SVC half connect detected
TRAP-TYPE    
  slotNumber  
  svcHalfConCnt  

duplicateIpAddr 1.3.6.1.4.1.251.1.1.164
Sent When a duplicate IP address is detected.
TRAP-TYPE    
  sysLastTrapMessage  
  qeDocMacAddress  

svcQsaalReset 1.3.6.1.4.1.251.1.1.165
Sent when SAP is reset
TRAP-TYPE    
  slotNumber  

svcQsaalUpDown 1.3.6.1.4.1.251.1.1.166
Sent when SAP transitions between Up and Down
TRAP-TYPE    
  slotNumber  

svcT309Expiry 1.3.6.1.4.1.251.1.1.167
Sent when T309 timer expired and calls exist on a SAP
TRAP-TYPE    
  slotNumber  

j2LOS 1.3.6.1.4.1.251.1.1.168
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  j2LOSAlarm  

j2LOF 1.3.6.1.4.1.251.1.1.169
Loss of Frame alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  j2LOFAlarm  

j2AIS 1.3.6.1.4.1.251.1.1.170
AIS alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  j2AISAlarm  

j2RAI 1.3.6.1.4.1.251.1.1.171
RAI alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  j2RAlmAlarm  

scfLOS 1.3.6.1.4.1.251.1.1.172
Loss of Signal alarm
TRAP-TYPE    
  sysLastTrapMessage  
  slotNumber  
  sysLkLinkNo  
  scfLOSAlarm  

routeLoadFail 1.3.6.1.4.1.251.1.1.173
def.rtb file load failure
TRAP-TYPE    
  slotNumber  

dTLLoadFail 1.3.6.1.4.1.251.1.1.174
dtl.bin file load failure
TRAP-TYPE    
  slotNumber  

redunNotAvail 1.3.6.1.4.1.251.1.1.175
This is sent when the Redundant Slot 0 Controller is not available
TRAP-TYPE    
  sysLastTrapMessage  
  slot0IsStandbySlot0  

redunAvail 1.3.6.1.4.1.251.1.1.176
This is sent when the Redundant Slot 0 Controller is available
TRAP-TYPE    
  sysLastTrapMessage  
  slot0IsStandbySlot0  

dQ7-error 1.3.6.1.4.1.251.1.1.177
This trap is sent when edos discovers a DQ7 error in flash
TRAP-TYPE    
  slotNumber  

oamVcaRcvAIS-RDI 1.3.6.1.4.1.251.1.1.178
This trap is generated when an AIS or RDI is received on VCa port
TRAP-TYPE    
  sysLastTrapMessage  
  oamVcaVpi  
  oamVcaVci  
  oamVcaAisRdiState  

oamVcbRcvAIS-RDI 1.3.6.1.4.1.251.1.1.179
This trap is generated when an AIS or RDI is received on VCb port
TRAP-TYPE    
  sysLastTrapMessage  
  oamVcbVpi  
  oamVcbVci  
  oamVcbAisRdiState  

Defined Objects

VirtualCircuitIdentifier  
INTEGER 0..65535    

VirtualPathIdentifier  
INTEGER 0..4095    

E164  
OCTET STRING SIZE(2..10)    

E164SUB  
OCTET STRING SIZE(2..22)    

Q93bCauseDiag  
OCTET STRING SIZE(4)    

Hex  
INTEGER 0..65535    

DateTimeString  
OCTET STRING SIZE(8)    

DateAndTime  
DateTimeString    

SysLinkEntry  
SEQUENCE    
  INTEGER as sysLkLinkNo  
  INTEGER as sysLkKillLink  
  INTEGER as sysLkState  
  Counter as sysLkTxCells  
  Counter as sysLkRxCells  
  Gauge as sysLkTxRate  
  Gauge as sysLkRxRate  
  Gauge as sysLkTxMaxRate  
  Gauge as sysLkRxMaxRate  
  INTEGER as sysLkResetStats  
  INTEGER as sysLkClockSrc  
  INTEGER as sysLkResetResrc  
  INTEGER as sysLKEgCLPThreshold  
  INTEGER as sysLKIgCLPThreshold  
  INTEGER as sysLKEgEFCIThreshold  
  INTEGER as sysLKIgEFCIThreshold  
  INTEGER as sysLKEgLogBuffer  
  INTEGER as sysLKIgLogBuffer  
  INTEGER as sysLKEgFIFODepth  
  INTEGER as sysLKIgFIFODepth  
  INTEGER as sysLKEgMemBlockId  
  INTEGER as sysLKIgMemBlockId  

SysDbEntry  
SEQUENCE    
  INTEGER as sysDbIndex  
  INTEGER as sysDbSize  
  INTEGER as sysDbInitial  
  INTEGER as sysDbCurrent  

SysAuthenticateEntry  
SEQUENCE    
  INTEGER as sysAuIndex  
  IpAddress as sysAuIpaddress  
  DisplayString as sysAuCommunity  
  INTEGER as sysAuAccess  
  INTEGER as sysAuSendTraps  
  INTEGER as sysAuValidity  

Slot0PsuEntry  
SEQUENCE    
  INTEGER as slot0PsuIndex  
  INTEGER as slot0PsuFault  
  INTEGER as slot0PsuTestFault  
  INTEGER as slot0PsuVoltage  
  INTEGER as slot0PsuTemp  
  INTEGER as slot0PsuFanASpeed  
  INTEGER as slot0PsuFanBSpeed  
  INTEGER as slot0PsuFanCSpeed  
  INTEGER as slot0PsuReset  
  INTEGER as slot0PsuType  
  INTEGER as slot0PsuFanFail  
  INTEGER as slot0PsuTooHot  
  INTEGER as slot0PsuFrontTooHot  

Slot0PhyEntry  
SEQUENCE    
  INTEGER as slot0PhySlotNo  
  DisplayString as slot0PhyName  
  INTEGER as slot0PhyType  
  INTEGER as slot0PhyDlim  
  DisplayString as slot0PhySwVer  
  INTEGER as slot0PhyState  
  INTEGER as slot0PhyReset  
  INTEGER as slot0PhyReqState  
  INTEGER as slot0PhyStateChange  
  INTEGER as slot0PhyLinkedSlot  
  INTEGER as slot0PhyLink0State  
  INTEGER as slot0PhyLink1State  
  INTEGER as slot0PhyLink2State  
  INTEGER as slot0PhyLink3State  
  DisplayString as slot0PhySlotSerNo  
  DisplayString as slot0PhySlotHwVerNo  
  DisplayString as slot0PhyDocSerNo  
  DisplayString as slot0PhyDocHwVerNo  
  PhysAddress as slot0PhyMacAddress  
  DateAndTime as slot0PhyChangeTimeM2  
  INTEGER as slot0PhyLstChngLnkNum  
  INTEGER as slot0PhyLstChngPrevLnkStat  

PrimaryEntry  
SEQUENCE    
  INTEGER as pIndex  
  INTEGER as pValidSource  
  INTEGER as pOnOffLine  
  INTEGER as pSlotNumber  
  INTEGER as pSysRefSelect  
  INTEGER as pActiveTimingSource  
  INTEGER as pInputLineOk  
  INTEGER as pSysRefTimingOk  

SecondaryEntry  
SEQUENCE    
  INTEGER as sIndex  
  INTEGER as sValidSource  
  INTEGER as sOnOffLine  
  INTEGER as sSlotNumber  
  INTEGER as sSysRefSelect  
  INTEGER as sActiveTimingSource  
  INTEGER as sInputLineOk  
  INTEGER as sSysRefTimingOk  

PCATcontrolEntry  
SEQUENCE    
  INTEGER as pccIndex  
  INTEGER as pccatlimtype  
  INTEGER as pccatsendcode  
  INTEGER as pccatactivate  
  INTEGER as pccatsendconfig  
  INTEGER as pccatbytestransferred  
  INTEGER as pccatfilexferstat  
  INTEGER as pcatforcesecext  
  INTEGER as pcatforcesecstr3  
  INTEGER as pcatcommand  
  INTEGER as pcatplaceholder1  
  INTEGER as pcatplaceholder2  
  INTEGER as pcconoffline  

SCATcontrolEntry  
SEQUENCE    
  INTEGER as sccIndex  
  INTEGER as sccatlimtype  
  INTEGER as sccatsendcode  
  INTEGER as sccatactivate  
  INTEGER as sccatsendconfig  
  INTEGER as sccatbytestransferred  
  INTEGER as sccatfilexferstat  
  INTEGER as scatcommand  
  INTEGER as scatplaceholder1  
  INTEGER as scatplaceholder2  
  INTEGER as scconoffline  

PCATstatusEntry  
SEQUENCE    
  INTEGER as pscIndex  
  INTEGER as pscatlimtype  
  DisplayString as psCATFFrevision  
  DisplayString as psCATBootrevision  
  INTEGER as psCATHWrevision  
  INTEGER as pscatfilestatus  
  DisplayString as psCATfilerevision  
  INTEGER as pscatmode  
  INTEGER as pscaterrorcode  
  INTEGER as pscatplaceholder1  
  INTEGER as pscatplaceholder2  

SCATstatusEntry  
SEQUENCE    
  INTEGER as sscIndex  
  INTEGER as sscatlimtype  
  DisplayString as ssCATFFrevision  
  DisplayString as ssCATBootrevision  
  INTEGER as sscatfilestatus  
  DisplayString as ssCATfilerevision  
  INTEGER as ssCATHWrevision  
  INTEGER as sscatmode  
  INTEGER as sscaterrorcode  
  INTEGER as sscatplaceholder1  
  INTEGER as sscatplaceholder2  

PCATStratum3ConfigEntry  
SEQUENCE    
  INTEGER as ps3cIndex  
  INTEGER as pcatstr3listener  
  INTEGER as pcatstr3oscillator  
  INTEGER as pcatstr3forcesecondary  
  INTEGER as pcatstr3reconfigure  

SCATStratum3ConfigEntry  
SEQUENCE    
  INTEGER as ss3cIndex  
  INTEGER as scatstr3listener  
  INTEGER as scatstr3oscillator  
  INTEGER as scatstr3reconfigure  

PCATStratum3StatusEntry  
SEQUENCE    
  INTEGER as ps3sIndex  
  INTEGER as pcatstr3listenerstatus  
  INTEGER as pcatstr3driverstatus  
  INTEGER as pcatstr3oscstatus  

SCATStratum3StatusEntry  
SEQUENCE    
  INTEGER as ss3sIndex  
  INTEGER as scatstr3listenerstatus  
  INTEGER as scatstr3driverstatus  
  INTEGER as scatstr3oscstatus  

PCATBitsConfigEntry  
SEQUENCE    
  INTEGER as pbcIndex  
  INTEGER as pbcds1V2TxLineLn  
  INTEGER as pbcplaceholder1  
  INTEGER as pbcV2FRMRMode  
  INTEGER as pbcds1V2Coding  
  INTEGER as pbcV2Lb  
  INTEGER as pbcclrperf  
  INTEGER as pbcreconfigure  

SCATBitsConfigEntry  
SEQUENCE    
  INTEGER as sbcIndex  
  INTEGER as sbcds1V2TxLineLn  
  INTEGER as sbcplaceholder1  
  INTEGER as sbcV2FRMRMode  
  INTEGER as sbcds1V2Coding  
  INTEGER as sbcV2Lb  
  INTEGER as sbcclrperf  
  INTEGER as sbcreconfigure  

PCATBitsStatusEntry  
SEQUENCE    
  INTEGER as pbsIndex  
  INTEGER as pbslineok  
  INTEGER as pbsV2RxAIS  
  INTEGER as pbsV2RxLOS  
  INTEGER as pbsV2RxOOF  
  INTEGER as pbsV2RxBER  
  INTEGER as pbsV2RxOOFCnt  
  INTEGER as pbsV2RxBERCnt  
  INTEGER as pbsV2RxLOSCnt  
  INTEGER as pbsV2LCVCnt  

SCATBitsStatusEntry  
SEQUENCE    
  INTEGER as sbsIndex  
  INTEGER as sbslineok  
  INTEGER as sbsV2RxAIS  
  INTEGER as sbsV2RxLOS  
  INTEGER as sbsV2RxOOF  
  INTEGER as sbsV2RxBER  
  INTEGER as sbsV2RxOOFCnt  
  INTEGER as sbsV2RxBERCnt  
  INTEGER as sbsV2RxLOSCnt  
  INTEGER as sbsV2LCVCnt  

PCATDerConfigEntry  
SEQUENCE    
  INTEGER as pdcIndex  
  INTEGER as pdcds1V2TxLineLn  
  INTEGER as pdcplaceholder1  
  INTEGER as pdcV2FRMRMode  
  INTEGER as pdcds1V2Coding  
  INTEGER as pdcV2Lb  
  INTEGER as pdcclrperf  
  INTEGER as pdcreconfigure  

SCATDerConfigEntry  
SEQUENCE    
  INTEGER as sdcIndex  
  INTEGER as sdcds1V2TxLineLn  
  INTEGER as sdcplaceholder1  
  INTEGER as sdcV2FRMRMode  
  INTEGER as sdcds1V2Coding  
  INTEGER as sdcV2Lb  
  INTEGER as sdcclrperf  
  INTEGER as sdcreconfigure  

PCATDerStatusEntry  
SEQUENCE    
  INTEGER as pdsIndex  
  INTEGER as pdslineok  
  INTEGER as pdsV2TxReference  
  INTEGER as pdsV2RxAIS  
  INTEGER as pdsV2RxLOS  
  INTEGER as pdsV2RxOOF  
  INTEGER as pdsV2RxBER  
  INTEGER as pdsV2RxOOFCnt  
  INTEGER as pdsV2RxBERCnt  
  INTEGER as pdsV2RxLOSCnt  
  INTEGER as pdsV2LCVCnt  

SCATDerStatusEntry  
SEQUENCE    
  INTEGER as sdsIndex  
  INTEGER as sdslineok  
  INTEGER as sdsV2TxReference  
  INTEGER as sdsV2RxAIS  
  INTEGER as sdsV2RxLOS  
  INTEGER as sdsV2RxOOF  
  INTEGER as sdsV2RxBER  
  INTEGER as sdsV2RxOOFCnt  
  INTEGER as sdsV2RxBERCnt  
  INTEGER as sdsV2RxLOSCnt  
  INTEGER as sdsV2LCVCnt  

VcDocEntry  
SEQUENCE    
  INTEGER as vcDocLinkNo  
  INTEGER as vcDocEnable  
  VirtualPathIdentifier as vcDocVpi  
  VirtualCircuitIdentifier as vcDocVci  
  INTEGER as vcDocLinkSpeed  
  INTEGER as vcDocCLines  
  INTEGER as vcDocFifoSize  
  INTEGER as vcDocLowWater  
  INTEGER as vcDocHighWater  
  INTEGER as vcDocTestMode  
  Hex as vcDocTestVal  
  INTEGER as vcDocPriority  
  INTEGER as vcDocSuba  
  INTEGER as vcDocSaddr  
  INTEGER as vcDocClockFix  

VcStatEntry  
SEQUENCE    
  INTEGER as vcStatPortNo  
  INTEGER as vcStatRxState  
  INTEGER as vcStatTxState  
  INTEGER as vcStatFifoCount  
  INTEGER as vcStatOFlow  
  INTEGER as vcStatUFlow  
  INTEGER as vcStatReSync  
  INTEGER as vcStatInvented  
  Counter as vcStatRxCells  
  Counter as vcStatTxCells  
  INTEGER as vcStatRxSeqNo  
  INTEGER as vcStatTxSeqNo  
  INTEGER as vcStatLastError  
  INTEGER as vcStatLastCompare  
  INTEGER as vcStatTestErrors  

FRelayStatEntry  
SEQUENCE    
  INTEGER as fRelStatLinkNo  
  INTEGER as fRelStatLocSeq  
  INTEGER as fRelStatLocAck  
  INTEGER as fRelStatLocState  
  INTEGER as fRelStatLocStartT  
  Counter as fRelStatLocErrThr  
  Counter as fRelStatLocMec  
  Counter as fRelStatLocPoll  
  INTEGER as fRelStatRemSeq  
  INTEGER as fRelStatRemAck  
  INTEGER as fRelStatRemState  
  INTEGER as fRelStatRemStartT  
  Counter as fRelStatRemErrThr  
  Counter as fRelStatRemMec  
  Counter as fRelStatRemPoll  

FRelayConfEntry  
SEQUENCE    
  INTEGER as fRelConfLinkNo  
  INTEGER as fRelConfLinkEnab  
  INTEGER as fRelConfLinkMode  
  INTEGER as fRelConfLinkSpeed  
  INTEGER as fRelConfLinkCline  
  INTEGER as fRelConfLinkType  
  INTEGER as fRelConfN391  
  INTEGER as fRelConfN392  
  INTEGER as fRelConfN393  
  INTEGER as fRelConfT391  
  INTEGER as fRelConfT392  

FraPStatEntry  
SEQUENCE    
  INTEGER as fraPStatDlci  
  Counter as fraPStatRxBCnt  
  Counter as fraPStatTxBCnt  
  Counter as fraPStatRxFCnt  
  Counter as fraPStatTxFCnt  
  Gauge as fraPStatRxBRate  
  Gauge as fraPStatTxBRate  
  Gauge as fraPStatRxFRate  
  Gauge as fraPStatTxFRate  
  Counter as fraPStatDERxF  
  Counter as fraPStatDisRxF  
  Hex as fraPStatPvcStat  
  Hex as fraPStatLinkState  
  INTEGER as fraPStatLocSeq  
  INTEGER as fraPStatLocAck  
  INTEGER as fraPStatLocStat  
  INTEGER as fraPStatLocStartT  
  Counter as fraPStatLocErrThr  
  Counter as fraPStatLocMec  
  Counter as fraPStatLocPoll  
  INTEGER as fraPStatRemSeq  
  INTEGER as fraPStatRemAck  
  INTEGER as fraPStatRemStat  
  INTEGER as fraPStatRemStartT  
  Counter as fraPStatRemErrThr  
  Counter as fraPStatRemMec  
  Counter as fraPStatRemPoll  
  DateAndTime as fraPStatLastChangeM2  

FraPConfigEntry  
SEQUENCE    
  INTEGER as fraPConfigDlci  
  INTEGER as fraPConfigCir  
  INTEGER as fraPConfigCommitB  
  INTEGER as fraPConfigExcessB  
  VirtualCircuitIdentifier as fraVci  
  VirtualPathIdentifier as fraVpi  
  INTEGER as fraPConfigPriority  
  INTEGER as fraPConfigSuba  
  INTEGER as fraPConfigSaddr  
  INTEGER as fraPConfigValidity  
  INTEGER as fraPConfigDxivpi  
  INTEGER as fraPConfigDxivci  
  INTEGER as fraPConfigDximode  

FrbPStatEntry  
SEQUENCE    
  INTEGER as frbPStatDlci  
  Counter as frbPStatRxBCnt  
  Counter as frbPStatTxBCnt  
  Counter as frbPStatRxFCnt  
  Counter as frbPStatTxFCnt  
  Gauge as frbPStatRxBRate  
  Gauge as frbPStatTxBRate  
  Gauge as frbPStatRxFRate  
  Gauge as frbPStatTxFRate  
  Counter as frbPStatDERxF  
  Counter as frbPStatDisRxF  
  Hex as frbPStatPvcStat  
  Hex as frbPStatLinkState  
  INTEGER as frbPStatLocSeq  
  INTEGER as frbPStatLocAck  
  INTEGER as frbPStatLocStat  
  INTEGER as frbPStatLocStartT  
  Counter as frbPStatLocErrThr  
  Counter as frbPStatLocMec  
  Counter as frbPStatLocPoll  
  INTEGER as frbPStatRemSeq  
  INTEGER as frbPStatRemAck  
  INTEGER as frbPStatRemStat  
  INTEGER as frbPStatRemStartT  
  Counter as frbPStatRemErrThr  
  Counter as frbPStatRemMec  
  Counter as frbPStatRemPoll  
  DateAndTime as frbPStatLastChangeM2  

FrbPConfigEntry  
SEQUENCE    
  INTEGER as frbPConfigDlci  
  INTEGER as frbPConfigCir  
  INTEGER as frbPConfigCommitB  
  INTEGER as frbPConfigExcessB  
  VirtualPathIdentifier as frbVpi  
  VirtualCircuitIdentifier as frbVci  
  INTEGER as frbPConfigPriority  
  INTEGER as frbPConfigSuba  
  INTEGER as frbPConfigSaddr  
  INTEGER as frbPConfigValidity  
  INTEGER as frbPConfigDxivpi  
  INTEGER as frbPConfigDxivci  
  INTEGER as frbPConfigDximode  

VcaEntry  
SEQUENCE    
  INTEGER as vcaVpi  
  INTEGER as vcaVci  
  Counter as vcaTxGCells  
  Counter as vcaTxGCellsClp1  
  Counter as vcaRxGCells  
  Counter as vcaExcessCells  
  Counter as vcaPeakExceeds  
  Hex as vcaCellHead  
  Hex as vcaCellMask  
  Hex as vcaCellSwitchHead  
  INTEGER as vcaStartTime  
  Hex as vcaBucketControl  
  Gauge as vcaBucket0CV  
  Gauge as vcaBucket0Max  
  INTEGER as vcaBucket0Inc  
  Gauge as vcaBucket1CV  
  Gauge as vcaBucket1Max  
  INTEGER as vcaBucket1Inc  
  Gauge as vcaBucket2CV  
  Gauge as vcaBucket2Max  
  INTEGER as vcaBucket2Inc  
  Gauge as vcaBucket3CV  
  Gauge as vcaBucket3Max  
  INTEGER as vcaBucket3Inc  
  INTEGER as vcaType  
  INTEGER as vcaDstSlot  
  INTEGER as vcaDstLink  
  INTEGER as vcaDstVpi  
  INTEGER as vcaDstVci  
  INTEGER as vcaInternalVpi  
  INTEGER as vcaInternalVci  

VcbEntry  
SEQUENCE    
  INTEGER as vcbVpi  
  INTEGER as vcbVci  
  Counter as vcbTxGCells  
  Counter as vcbTxGCellsClp1  
  Counter as vcbRxGCells  
  Counter as vcbExcessCells  
  Counter as vcbPeakExceeds  
  Hex as vcbCellHead  
  Hex as vcbCellMask  
  Hex as vcbCellSwitchHead  
  INTEGER as vcbStartTime  
  Hex as vcbBucketControl  
  Gauge as vcbBucket0CV  
  Gauge as vcbBucket0Max  
  INTEGER as vcbBucket0Inc  
  Gauge as vcbBucket1CV  
  Gauge as vcbBucket1Max  
  INTEGER as vcbBucket1Inc  
  Gauge as vcbBucket2CV  
  Gauge as vcbBucket2Max  
  INTEGER as vcbBucket2Inc  
  Gauge as vcbBucket3CV  
  Gauge as vcbBucket3Max  
  INTEGER as vcbBucket3Inc  
  INTEGER as vcbType  
  INTEGER as vcbDstSlot  
  INTEGER as vcbDstLink  
  INTEGER as vcbDstVpi  
  INTEGER as vcbDstVci  
  INTEGER as vcbInternalVpi  
  INTEGER as vcbInternalVci  

XpStatEntry  
SEQUENCE    
  INTEGER as xpIFace  
  Counter as xpRXCells  
  Counter as xpTXCells  
  Counter as xpBadVpiVci  
  Counter as xpRxOverflow  
  Counter as xpTxHighPrOver  
  Counter as xpTxLowPrOver  
  Counter as xpInputOverflow  
  Counter as xpDocErrors  
  Counter as xpLowPriorityFifo  
  Counter as xpEgDiscCells  
  Counter as xpIgDiscCells  

PdhPLCPEntry  
SEQUENCE    
  INTEGER as pdhPLCPLinkNo  
  INTEGER as pdhPLCPLinkEnable  
  INTEGER as pdhPLCPLinkStatusAffect  
  INTEGER as pdhPLCPLinkState  
  INTEGER as pdhPLCPPhyMode  
  INTEGER as pdhPLCPMode  
  INTEGER as pdhPLCPScrambler  
  INTEGER as pdhPLCP0x55  
  INTEGER as pdhPLCPSmdsMode  
  INTEGER as pdhPLCPIdleCell  
  INTEGER as pdhPLCPLoopback  
  INTEGER as pdhPLCPClear  
  INTEGER as pdhPLCPReconfig  
  INTEGER as pdhPLCPLpbkTimeout  
  INTEGER as pdhPLCPChipType  
  INTEGER as pdhPLCPTXclock  
  INTEGER as pdhPLCPRXclock  
  Counter as pdhPLCPTXCells  
  Counter as pdhPLCPRXCells  
  Counter as pdhPLCPHCSErrs  
  INTEGER as pdhPLCPLOCDDefect  
  INTEGER as pdhPLCPYellowDefect  
  INTEGER as pdhPLCPLOFDefect  
  INTEGER as pdhPLCPLOCDAlarm  
  INTEGER as pdhPLCPYellowAlarm  
  INTEGER as pdhPLCPLOFAlarm  
  Counter as pdhPLCPFrameErrs  
  Counter as pdhPLCPBIP8Errs  
  Counter as pdhPLCPFEBEErrs  
  Counter as pdhPLCPES  
  Counter as pdhPLCPSES  
  Counter as pdhPLCPUAS  
  Counter as pdhPLCPFEES  
  Counter as pdhPLCPFESES  
  Counter as pdhPLCPFEUAS  

PdhDS3Entry  
SEQUENCE    
  INTEGER as pdhDS3TableValid  
  INTEGER as pdhDS3LinkNo  
  INTEGER as pdhDS3Framer  
  INTEGER as pdhDS3TxAIS  
  INTEGER as pdhDS3Clear  
  INTEGER as pdhDS3Reconfig  
  INTEGER as pdhDS3RxFrmFmt  
  INTEGER as pdhDS3RxIDL  
  INTEGER as pdhDS3FEACTxmt  
  Counter as pdhDS3Lcvs  
  Counter as pdhDS3FrameErrs  
  Counter as pdhDS3ParityErrs  
  Counter as pdhDS3CbitPrtyErrs  
  Counter as pdhDS3FEBEErrs  
  INTEGER as pdhDS3LOSDefect  
  INTEGER as pdhDS3OOFDefect  
  INTEGER as pdhDS3AISDefect  
  INTEGER as pdhDS3YellowDefect  
  INTEGER as pdhDS3ExBERDefect  
  INTEGER as pdhDS3LOSAlarm  
  INTEGER as pdhDS3LOFAlarm  
  INTEGER as pdhDS3AISAlarm  
  INTEGER as pdhDS3YellowAlarm  
  INTEGER as pdhDS3ExBERAlarm  
  Counter as pdhDS3LES  
  Counter as pdhDS3LSES  
  Counter as pdhDS3ES  
  Counter as pdhDS3ES2  
  Counter as pdhDS3SES  
  Counter as pdhDS3SES2  
  Counter as pdhDS3AISS  
  Counter as pdhDS3UAS  
  Counter as pdhDS3FarEndES  
  Counter as pdhDS3FarEndSES  
  Counter as pdhDS3FarEndUAS  

PdhE3Entry  
SEQUENCE    
  INTEGER as pdhE3TableValid  
  INTEGER as pdhE3LinkNo  
  INTEGER as pdhE3Framer  
  INTEGER as pdhE3Clear  
  INTEGER as pdhE3Reconfig  
  INTEGER as pdhE3TxmtTimMk  
  INTEGER as pdhE3PloadTypeLab  
  INTEGER as pdhE3TxTrlTrcIdLen  
  PhysAddress as pdhE3TxTrcIdUH  
  PhysAddress as pdhE3TxTrcIdLH  
  PhysAddress as pdhE3RxExTrcIdUH  
  PhysAddress as pdhE3RxExTrcIdLH  
  Counter as pdhE3FrameErrs  
  Counter as pdhE3Lcvs  
  Counter as pdhE3ParityErrs  
  Counter as pdhE3FEBEErrs  
  INTEGER as pdhE3LOSDefect  
  INTEGER as pdhE3OOFDefect  
  INTEGER as pdhE3AISDefect  
  INTEGER as pdhE3FERFDefect  
  INTEGER as pdhE3ExBERDefect  
  INTEGER as pdhE3LOSAlarm  
  INTEGER as pdhE3LOFAlarm  
  INTEGER as pdhE3AISAlarm  
  INTEGER as pdhE3FERFAlarm  
  INTEGER as pdhE3ExBERAlarm  
  Counter as pdhE3LES  
  Counter as pdhE3LSES  
  Counter as pdhE3ES  
  Counter as pdhE3SES  
  Counter as pdhE3AISS  
  Counter as pdhE3UAS  
  PhysAddress as pdhE3RxTrlTrc  
  INTEGER as pdhE3RxTrIdMis  
  INTEGER as pdhE3RxTrIdUnst  
  INTEGER as pdhE3RxPloadTypeLabMis  
  INTEGER as pdhE3RxPloadTypeLabUnst  

PlppCEntry  
SEQUENCE    
  INTEGER as plppCLinkNo  
  INTEGER as plppCLinkEnab  
  INTEGER as plppCCPLCPMode  
  INTEGER as plppCDS3Framer  
  INTEGER as plppCScrambler  
  INTEGER as plppC0x55  
  INTEGER as plppCCLine  
  INTEGER as plppCLoopback  
  INTEGER as plppCSmdsMode  
  INTEGER as plppCPloadTypeLab  
  INTEGER as plppCTxTrlTrcIdLen  
  PhysAddress as plppCTxTrcId  
  PhysAddress as plppCRxExTrcId  

PlppSEntry  
SEQUENCE    
  INTEGER as plppSLinkNo  
  INTEGER as plppSCLines  
  INTEGER as plppSTXclock  
  INTEGER as plppSRXclock  
  Counter as plppSTXCells  
  Counter as plppSRXCells  
  Counter as plppSHCSErrs  
  Counter as plppSFrameErrs  
  Counter as plppSBIP8Errs  
  Counter as plppSFEBEErrs  
  INTEGER as plppSSPLRStatus  
  Counter as plppSDs3Lcvs  
  Counter as plppSDs3FrameErrs  
  Counter as plppSDs3ParityErrs  
  Counter as plppSDs3CbitPrtyErrs  
  Counter as plppSDs3FEBEErrs  
  INTEGER as plppSDs3RxAIS  
  INTEGER as plppSDs3RxRedAlarm  
  INTEGER as plppSDs3RxYellowAlarm  
  INTEGER as plppSPLCPRxYellowAlarm  
  INTEGER as plppsRxTrIdMis  
  INTEGER as plppsRxTrIdUnst  
  INTEGER as plppsRxPloadTypeLabMis  
  INTEGER as plppsRxPloadTypeLabUnst  
  PhysAddress as plppsRxTrlTrc  

PlppV2CEntry  
SEQUENCE    
  INTEGER as plppV2CLinkNo  
  INTEGER as plppV2CLinkEnab  
  INTEGER as plppV2CCPLCPMode  
  INTEGER as plppV2CDS3Framer  
  INTEGER as plppV2CScrambler  
  INTEGER as plppV2C0x55  
  INTEGER as plppV2CLoopback  
  INTEGER as plppV2CSmdsMode  
  INTEGER as plppV2CFrmFmt  
  INTEGER as plppV2CTxAIS  

PlppV2SEntry  
SEQUENCE    
  INTEGER as plppV2SLinkNo  
  INTEGER as plppV2STXclock  
  INTEGER as plppV2SRXclock  
  Counter as plppV2STXCells  
  Counter as plppV2SRXCells  
  Counter as plppV2SHCSErrs  
  Counter as plppV2SFrameErrs  
  Counter as plppV2SBIP8Errs  
  Counter as plppV2SFEBEErrs  
  INTEGER as plppV2SSPLRStatus  
  INTEGER as plppV2SDs3FrmFmt  
  Counter as plppV2SDs3Lcvs  
  Counter as plppV2SDs3FrameErrs  
  Counter as plppV2SDs3ParityErrs  
  Counter as plppV2SDs3CbitPrtyErrs  
  Counter as plppV2SDs3FEBEErrs  
  INTEGER as plppV2SDs3RxAIS  
  INTEGER as plppV2SDs3RxRedAlarm  
  INTEGER as plppV2SDs3RxYellowAlarm  
  INTEGER as plppV2SPLCPRxYellowAlarm  
  INTEGER as plppV2SDs3FEACTxmt  
  INTEGER as plppV2SRxIDL  
  INTEGER as plppV2SLOC  
  INTEGER as plppV2SDs3LPBK  

PlppE1CEntry  
SEQUENCE    
  INTEGER as plppE1CLinkNo  
  INTEGER as plppE1CLinkEnab  
  INTEGER as plppE1CScrambler  
  INTEGER as plppE1C0x55  
  INTEGER as plppE1CSmdsMode  
  INTEGER as plppE1CLpbk  

PlppE1SEntry  
SEQUENCE    
  INTEGER as plppE1SLinkNo  
  INTEGER as plppE1STXclock  
  INTEGER as plppE1SRXclock  
  Counter as plppE1STXCells  
  Counter as plppE1SRXCells  
  Counter as plppE1SHCSErrs  
  Counter as plppE1SCRCErrs  
  Counter as plppE1SFrameErrs  
  Counter as plppE1SFEBEErrs  
  Counter as plppE1SLcvs  
  INTEGER as plppE1SRxAIS  
  INTEGER as plppE1SRxOOF  
  INTEGER as plppE1SRxLOS  
  INTEGER as plppE1SRxLOF  
  INTEGER as plppE1SFerf  

PlppE3CEntry  
SEQUENCE    
  INTEGER as plppE3CLinkNo  
  INTEGER as plppE3CLinkEnab  
  INTEGER as plppE3CFramer  
  INTEGER as plppE3CPLCPMode  
  INTEGER as plppE3CScrambler  
  INTEGER as plppE3C0x55  
  INTEGER as plppE3CLoopback  
  INTEGER as plppE3CSmdsMode  
  INTEGER as plppE3CTxmtTimMk  
  INTEGER as plppE3CPloadTypeLab  
  INTEGER as plppE3CTxTrlTrcIdLen  
  PhysAddress as plppE3CTxTrcIdUH  
  PhysAddress as plppE3CTxTrcIdLH  
  PhysAddress as plppE3CRxExTrcIdUH  
  PhysAddress as plppE3CRxExTrcIdLH  

PlppE3SEntry  
SEQUENCE    
  INTEGER as plppE3SLinkNo  
  INTEGER as plppE3STXclock  
  INTEGER as plppE3SRXclock  
  Counter as plppE3STXCells  
  Counter as plppE3SRXCells  
  Counter as plppE3SHCSErrs  
  Counter as plppE3SE3FrameErrs  
  Counter as plppE3SPLCPFrameErrs  
  Counter as plppE3SBIP8Errs  
  Counter as plppE3SFEBEErrs  
  Counter as plppE3SLcvs  
  INTEGER as plppE3SLcd  
  PhysAddress as plppE3SRxTrlTrc  
  INTEGER as plppE3SRxAIS  
  INTEGER as plppE3SRxOOF  
  INTEGER as plppE3SRxLOS  
  INTEGER as plppE3SRxLOF  
  INTEGER as plppE3SRxFERF  
  INTEGER as plppE3SPLCPRxLof  
  INTEGER as plppE3SPLCPRxYellowAlarm  
  INTEGER as plppE3SRxTrIdMis  
  INTEGER as plppE3SRxTrIdUnst  
  INTEGER as plppE3SRxPloadTypeLabMis  
  INTEGER as plppE3SRxPloadTypeLabUnst  

LFibreConfEntry  
SEQUENCE    
  INTEGER as lFibreConfLinkNo  
  INTEGER as lFibreConfLinkEnab  
  INTEGER as lFibreConfCLine  
  INTEGER as lFibreConfLoopback  

LFibreStatEntry  
SEQUENCE    
  INTEGER as lFibreStatLinkNo  
  INTEGER as lFibreStatCLines  
  Counter as lFibreStatHCSErrs  

Ds1Entry  
SEQUENCE    
  INTEGER as ds1LinkNo  
  INTEGER as ds1LineLength  
  INTEGER as ds1Framing  
  INTEGER as ds1Coding  
  INTEGER as ds1Tr  
  INTEGER as ds1Rt  
  INTEGER as ds1LOSDefect  
  INTEGER as ds1AISDefect  
  INTEGER as ds1OOFDefect  
  INTEGER as ds1YellowDefect  
  INTEGER as ds1LOSAlarm  
  INTEGER as ds1AISAlarm  
  INTEGER as ds1LOFAlarm  
  INTEGER as ds1YellowAlarm  
  Counter as ds1PdvCount  
  Counter as ds1Z16Count  
  Counter as ds1LcvCount  
  Counter as ds1BeeCount  
  Counter as ds1FerCount  
  Counter as ds1OofCount  
  INTEGER as ds1ClrStats  
  INTEGER as ds1Reconfig  
  Counter as ds1LineES  
  Counter as ds1LineSES  
  Counter as ds1ES  
  Counter as ds1SES  
  Counter as ds1AISS  
  Counter as ds1UAS  
  INTEGER as ds1TxClkSel  
  INTEGER as ds1ExBERDefect  
  INTEGER as ds1ExBERAlarm  

Ds3Entry  
SEQUENCE    
  INTEGER as ds3LinkNo  
  INTEGER as ds3Lb  
  INTEGER as ds3Err  
  INTEGER as ds3RXLos  
  INTEGER as ds3TXLoc  
  INTEGER as ds3RXErr  
  INTEGER as ds3RXAis  
  INTEGER as ds3TXAis  
  INTEGER as ds3TXLev  
  INTEGER as ds3Tr  
  INTEGER as ds3Rt  
  INTEGER as ds3Equal  
  INTEGER as ds3LOSAlarm  
  INTEGER as ds3Reconfig  

E1Entry  
SEQUENCE    
  INTEGER as e1LinkNo  
  INTEGER as e1LimType  
  INTEGER as e1Lb  
  INTEGER as e1FRMRMode  
  INTEGER as e1TxClkSel  
  INTEGER as e1TS16PayLd  
  INTEGER as e1TxAIS  
  INTEGER as e1GappedClk  
  INTEGER as e1IntrfType  
  INTEGER as e1ClrStats  
  INTEGER as e1Reconfig  
  INTEGER as se1SA4  
  INTEGER as se1SA5  
  INTEGER as se1SA6  
  INTEGER as se1SA7  
  INTEGER as se1SA8  
  INTEGER as se1SI0  
  INTEGER as se1SI1  
  INTEGER as e1LOSDefect  
  INTEGER as e1OOFDefect  
  INTEGER as e1AISDefect  
  INTEGER as e1FerfDefect  
  INTEGER as e1ExBERDefect  
  INTEGER as e1LOSAlarm  
  INTEGER as e1LOFAlarm  
  INTEGER as e1AISAlarm  
  INTEGER as e1FerfAlarm  
  INTEGER as e1ExBERAlarm  
  INTEGER as e1SCRCErrs  
  INTEGER as e1SFrameErrs  
  INTEGER as e1SFEBEErrs  
  INTEGER as e1SLcvs  
  Counter as e1LineES  
  Counter as e1LineSES  
  Counter as e1ES  
  Counter as e1SES  
  Counter as e1AISS  
  Counter as e1UAS  

SoEntry  
SEQUENCE    
  INTEGER as soLinkNo  
  INTEGER as soLimType  
  INTEGER as soTimingRef  
  INTEGER as soTxEn0  
  INTEGER as soTxEn1  
  INTEGER as soLimDesc  
  INTEGER as soReconfig  

Ds1V2Entry  
SEQUENCE    
  INTEGER as ds1V2LinkNo  
  INTEGER as ds1V2LimType  
  INTEGER as ds1V2TxLineLn  
  INTEGER as ds1V2FRMRMode  
  INTEGER as ds1V2Coding  
  INTEGER as ds1V2Lb  
  INTEGER as ds1V2TxAIS  
  INTEGER as ds1V2GappedClk  
  INTEGER as ds1V2TxClkSel  
  INTEGER as ds1V2ClrStats  
  INTEGER as ds1V2Reconfig  
  INTEGER as ds1V2LOSDefect  
  INTEGER as ds1V2OOFDefect  
  INTEGER as ds1V2AISDefect  
  INTEGER as ds1V2FerfDefect  
  INTEGER as ds1V2BERDefect  
  INTEGER as ds1V2LOSAlarm  
  INTEGER as ds1V2LOFAlarm  
  INTEGER as ds1V2AISAlarm  
  INTEGER as ds1V2FerfAlarm  
  INTEGER as ds1V2BERAlarm  
  INTEGER as ds1V2FerCount  
  INTEGER as ds1V2BeeCount  
  INTEGER as ds1V2OCfCount  
  INTEGER as ds1V2LcvCount  
  Counter as ds1V2LineES  
  Counter as ds1V2LineSES  
  Counter as ds1V2ES  
  Counter as ds1V2SES  
  Counter as ds1V2AISS  
  Counter as ds1V2UAS  
  Counter as ds1V2ExBER  

Ds3V2Entry  
SEQUENCE    
  INTEGER as ds3V2LinkNo  
  INTEGER as ds3V2Lb  
  INTEGER as ds3V2LimType  
  INTEGER as ds3V2LimOK  
  INTEGER as ds3V2TxLBO  
  INTEGER as ds3V2TxClkSel  
  INTEGER as ds3V2LOSDefect  
  INTEGER as ds3V2LOSAlarm  
  INTEGER as ds3V2Reconfig  

E3Entry  
SEQUENCE    
  INTEGER as e3LinkNo  
  INTEGER as e3LimType  
  INTEGER as e3LimOK  
  INTEGER as e3EQSelect  
  INTEGER as e3Loopback  
  INTEGER as e3TxAIS  
  INTEGER as e3TxClkSel  
  INTEGER as e3LOSDefect  
  INTEGER as e3LOSAlarm  
  INTEGER as e3Reconfig  

HssiEntry  
SEQUENCE    
  INTEGER as hssiLinkNo  
  INTEGER as hssiType  
  INTEGER as hssiLimType  
  INTEGER as hssiLinkReady  
  INTEGER as hssiRemoteReady  
  INTEGER as hssiClockSrc  
  INTEGER as hssiLocalLoopback  
  INTEGER as hssiRemoteLoopback  
  INTEGER as hssiCtrTestMode  
  INTEGER as hssiReconfig  
  INTEGER as hssiLOSDefect  
  INTEGER as hssiLOSAlarm  

J2Entry  
SEQUENCE    
  INTEGER as j2LinkNo  
  INTEGER as j2FirmwareRev  
  INTEGER as j2TxEq  
  INTEGER as j2Lb  
  INTEGER as j2TxAIS  
  INTEGER as j2TxClkSel  
  INTEGER as j2ClrStats  
  INTEGER as j2Reconfig  
  Hex as j2TS97TS98  
  INTEGER as j2QualClock  
  INTEGER as j2LOSDefect  
  INTEGER as j2OOFDefect  
  INTEGER as j2AISDefect  
  INTEGER as j2RAlmDefect  
  INTEGER as j2LOSAlarm  
  INTEGER as j2LOFAlarm  
  INTEGER as j2AISAlarm  
  INTEGER as j2RAlmAlarm  
  INTEGER as j2FerCount  
  INTEGER as j2RAlmCount  
  INTEGER as j2LcvCount  
  Counter as j2CrcCount  
  Counter as j2LineES  
  Counter as j2LineSES  
  Counter as j2ES  
  Counter as j2SES  
  Counter as j2AISS  
  Counter as j2UAS  

ScfEntry  
SEQUENCE    
  INTEGER as scfLinkNo  
  INTEGER as scfLimType  
  INTEGER as scfFirmwareRev  
  INTEGER as scfQualClock  
  INTEGER as scfContr  
  INTEGER as scfDCEDTE  
  INTEGER as scfLb  
  INTEGER as scfLineTiming  
  INTEGER as scfDataRate  
  INTEGER as scfClkSel  
  INTEGER as scfInterfaceType  
  INTEGER as scfReconfig  
  INTEGER as scfLOSDefect  
  INTEGER as scfLOSAlarm  

BillingEntry  
SEQUENCE    
  INTEGER as billSeq  
  VirtualPathIdentifier as billSvpi  
  VirtualCircuitIdentifier as billSvci  
  VirtualPathIdentifier as billDvpi  
  VirtualCircuitIdentifier as billDvci  
  INTEGER as billSslot  
  INTEGER as billSlink  
  INTEGER as billDslot  
  INTEGER as billDlink  
  E164 as billCalled  
  E164SUB as billCalledSub  
  E164 as billCalling  
  E164SUB as billCallingSub  
  Counter as billCellInC  
  Counter as billCellIn  
  Counter as billFrameIn  
  Counter as billByteInC  
  Counter as billByteIn  
  Counter as billCellOutC  
  Counter as billCellOut  
  Counter as billFrameOut  
  Counter as billByteOutC  
  Counter as billByteOut  
  INTEGER as billCause  
  INTEGER as billValid  
  Counter as billCLP1OutC  
  Counter as billCLP1Out  
  INTEGER as billTag  
  DateAndTime as billStartM2  
  DateAndTime as billEndM2  
  INTEGER as billFwdPCR  
  INTEGER as billBwdPCR  
  INTEGER as billFwdSCR  
  INTEGER as billBwdSCR  
  INTEGER as billFwdMBS  
  INTEGER as billBwdMBS  
  INTEGER as billFwdQOS  
  INTEGER as billBwdQOS  

QeDocBridgeEntry  
SEQUENCE    
  INTEGER as qeDocBridgeLinkNo  
  INTEGER as qeDocBridgeEnable  
  INTEGER as qeDocBridgeLink0Eligible  
  INTEGER as qeDocBridgeLink1Eligible  
  INTEGER as qeDocBridgeLink2Eligible  
  INTEGER as qeDocBridgeLink3Eligible  

QeDocTunEntry  
SEQUENCE    
  INTEGER as qeDocTunIndex  
  DisplayString as qeDocTunName  
  INTEGER as qeDocTunType  
  INTEGER as qeDocTunState  
  INTEGER as qeDocTunCallState  
  VirtualPathIdentifier as qeDocTunVPI  
  VirtualCircuitIdentifier as qeDocTunVCI  
  INTEGER as qeDocTunPriority  
  INTEGER as qeDocTunSlot  
  INTEGER as qeDocTunLink  
  Counter as qeDocTunInFrames  
  Counter as qeDocTunOutFrames  
  IpAddress as qeDocTunRemNet  
  IpAddress as qeDocTunRemMask  
  IpAddress as qeDocTunLocNet  
  IpAddress as qeDocTunLocMask  
  INTEGER as qeDocTunRemStartSkt  
  INTEGER as qeDocTunRemEndSkt  
  INTEGER as qeDocTunLocStartSkt  
  INTEGER as qeDocTunLocEndSkt  
  INTEGER as qeDocTunSktType  
  E164 as qeDocTunDestAddress  
  E164SUB as qeDocTunDestSubAddress  
  INTEGER as qeDocTunValidity  
  INTEGER as qeDocTunLink0Eligible  
  INTEGER as qeDocTunLink1Eligible  
  INTEGER as qeDocTunLink2Eligible  
  INTEGER as qeDocTunLink3Eligible  
  INTEGER as qeDocTunRfc1483Encap  
  INTEGER as qeDocTunClp  

SdhCEntry  
SEQUENCE    
  INTEGER as sdhCLinkNo  
  INTEGER as sdhCLinkEnab  
  INTEGER as sdhCLoopTimer  
  INTEGER as sdhCLoopDiag  
  INTEGER as sdhCLoopLine  
  INTEGER as sdhCScrambler  
  INTEGER as sdhC0x55  
  INTEGER as sdhSonetSdh  
  INTEGER as sdhClearCounts  
  INTEGER as sdhReconfig  
  INTEGER as sdhCLpbkTimeout  
  INTEGER as sdhStmSts  
  INTEGER as sdhAPSOnOff  
  INTEGER as sdhCIdleCell  

SdhSEntry  
SEQUENCE    
  INTEGER as sdhSLinkNo  
  INTEGER as sdhSTXclock  
  INTEGER as sdhSRXclock  
  INTEGER as sdhSSectLOS  
  INTEGER as sdhSSectOOF  
  INTEGER as sdhSSectLOF  
  INTEGER as sdhSLineAIS  
  INTEGER as sdhSLineFERF  
  INTEGER as sdhSPathAIS  
  INTEGER as sdhSPathYellow  
  INTEGER as sdhSPathFERF  
  INTEGER as sdhSPathLOP  
  INTEGER as sdhSPathLabelMM  
  INTEGER as sdhSExBERDefect  
  INTEGER as sdhSPathLabel  
  INTEGER as sdhSCellDelState  
  INTEGER as sdhSAlarmLOS  
  INTEGER as sdhSAlarmLOF  
  INTEGER as sdhSAlarmLineAIS  
  INTEGER as sdhSAlarmLineRFI  
  INTEGER as sdhSAlarmPathAIS  
  INTEGER as sdhSAlarmPathRFI  
  INTEGER as sdhSAlarmLOP  
  INTEGER as sdhSAlarmPLM  
  INTEGER as sdhSExBERAlarm  
  Counter as sdhSCorrHCS  
  Counter as sdhSUnCorrHCS  

SdhS2Entry  
SEQUENCE    
  INTEGER as sdhS2LinkNo  
  Counter as sdhSSectBIP8  
  Counter as sdhSSectES  
  Counter as sdhSSectSES  
  Counter as sdhSLineBIP24  
  Counter as sdhSLineES  
  Counter as sdhSLineSES  
  Counter as sdhSLineUAS  
  Counter as sdhSLineFC  
  Counter as sdhSPathBIP8  
  Counter as sdhSPathES  
  Counter as sdhSPathSES  
  Counter as sdhSPathUAS  
  Counter as sdhSPathFC  
  Counter as sdhSLineFEBE  
  Counter as sdhSLineFarEndES  
  Counter as sdhSLineFarEndSES  
  Counter as sdhSLineFarEndUAS  
  Counter as sdhSLineFarEndFC  
  Counter as sdhSPathFEBE  
  Counter as sdhSPathFarEndES  
  Counter as sdhSPathFarEndSES  
  Counter as sdhSPathFarEndUAS  
  Counter as sdhSPathFarEndFC  

PvcResourceEntry  
SEQUENCE    
  INTEGER as pvcSlot 0..15  
  INTEGER as pvcLink  
  VirtualCircuitIdentifier as pvcVciStart  
  VirtualCircuitIdentifier as pvcVciEnd  
  VirtualPathIdentifier as pvcVpiStart  
  VirtualPathIdentifier as pvcVpiEnd  
  VirtualPathIdentifier as pvcVpStart  
  VirtualPathIdentifier as pvcVpEnd  
  INTEGER as pvcBackwardCellRateTotal 0..16777215  
  INTEGER as pvcLinkQoS  
  INTEGER as pvcMolnVci  
  INTEGER as pvcMolnVpi  
  INTEGER as pvcLowPriOverbookFactor  

PvcEntry  
SEQUENCE    
  INTEGER as pvcDSlot 0..15  
  INTEGER as pvcDLink 0..3  
  VirtualCircuitIdentifier as pvcDvci  
  VirtualPathIdentifier as pvcDvpi  
  INTEGER as pvcSSlot 0..15  
  INTEGER as pvcSLink 0..3  
  VirtualCircuitIdentifier as pvcSvci  
  VirtualPathIdentifier as pvcSvpi  
  INTEGER as pvcForwardPeakCellRate 0..16777215  
  INTEGER as pvcForwardPeakSize 0..16777215  
  INTEGER as pvcForwardPeakMode  
  INTEGER as pvcBackwardPeakCellRate 0..16777215  
  INTEGER as pvcBackwardPeakSize 0..16777215  
  INTEGER as pvcBackwardPeakMode  
  INTEGER as pvcForwardSustainedCellRate 0..16777215  
  INTEGER as pvcForwardSustainedSize 0..16777215  
  INTEGER as pvcForwardSustainedMode  
  INTEGER as pvcBackwardSustainedCellRate 0..16777215  
  INTEGER as pvcBackwardSustainedSize 0..16777215  
  INTEGER as pvcBackwardSustainedMode  
  INTEGER as pvcAuxForwardPeakCellRate 0..16777215  
  INTEGER as pvcAuxForwardPeakSize 0..16777215  
  INTEGER as pvcAuxForwardPeakMode  
  INTEGER as pvcAuxBackwardPeakCellRate 0..16777215  
  INTEGER as pvcAuxBackwardPeakSize 0..16777215  
  INTEGER as pvcAuxBackwardPeakMode  
  INTEGER as pvcAuxForwardSustainedCellRate 0..16777215  
  INTEGER as pvcAuxForwardSustainedSize 0..16777215  
  INTEGER as pvcAuxForwardSustainedMode  
  INTEGER as pvcAuxBackwardSustainedCellRate 0..16777215  
  INTEGER as pvcAuxBackwardSustainedSize 0..16777215  
  INTEGER as pvcAuxBackwardSustainedMode  
  INTEGER as pvcQoSClass  
  INTEGER as pvcStatus  
  INTEGER as pvcMulticast  
  INTEGER as pvcInternalVpi  
  INTEGER as pvcInternalVci  
  INTEGER as pvcNumLeaves  
  INTEGER as pvcDirection  

SvcResourceEntry  
SEQUENCE    
  INTEGER as svcSAP 0..31  
  INTEGER as svcHiLo  
  INTEGER as svcVciStart 32..4095  
  INTEGER as svcVciEnd 32..4095  
  INTEGER as svcVpiStart 0..255  
  INTEGER as svcVpiEnd 0..255  
  INTEGER as svcVpStart 0..255  
  INTEGER as svcVpEnd 0..255  
  INTEGER as svcBackwardCellRateTotal 0..16777215  
  INTEGER as svcBackwardCellRateAvailable 0..16777215  
  INTEGER as svcSigVci 0..511  
  INTEGER as svcSigVpi 0..255  
  INTEGER as svcSAPStatus  
  INTEGER as svcCDVTSize  
  INTEGER as svcIntType  
  INTEGER as svcPolicing  
  INTEGER as svcLowPriOverbookFactor  
  INTEGER as svcMaxSapConn  
  INTEGER as svcCurSapConn  
  INTEGER as svcLinkNo 0..3  
  INTEGER as svcVpiMapping  
  INTEGER as svcQosRoute  
  INTEGER as svcSwtch  
  INTEGER as svcRestart  
  E164 as svcE164Addr  
  INTEGER as svcAutoSapOff  

SvcEntry  
SEQUENCE    
  INTEGER as svcId  
  INTEGER as svcDSlot 0..15  
  INTEGER as svcDLink 0..3  
  VirtualCircuitIdentifier as svcDvci  
  VirtualPathIdentifier as svcDvpi  
  E164 as svcDE164  
  E164SUB as svcDE164Sub  
  INTEGER as svcSSlot 0..15  
  INTEGER as svcSLink 0..3  
  VirtualCircuitIdentifier as svcSvci  
  VirtualPathIdentifier as svcSvpi  
  E164 as svcSE164  
  E164SUB as svcSE164Sub  
  INTEGER as svcForwardPeakCellRate 0..16777215  
  INTEGER as svcForwardPeakMode  
  INTEGER as svcBackwardPeakCellRate 0..16777215  
  INTEGER as svcBackwardPeakMode  
  INTEGER as svcForwardSustainableCellRate 0..16777215  
  INTEGER as svcForwardMaxBurstSize 0..16777215  
  INTEGER as svcForwardSustainableMode  
  INTEGER as svcBackwardSustainableCellRate 0..16777215  
  INTEGER as svcBackwardMaxBurstSize 0..16777215  
  INTEGER as svcBackwardSustainableMode  
  INTEGER as svcQoSClass  
  INTEGER as svcBillTag  
  Counter as svcDuration  
  INTEGER as svcType  
  INTEGER as svcStatus  
  INTEGER as svcNumLeaves  
  INTEGER as svcInternalVpi  
  INTEGER as svcInternalVci  

SPvcEntry  
SEQUENCE    
  INTEGER as sPvcId  
  INTEGER as sPvcCallId  
  INTEGER as sPvcLink  
  E164 as sPvcAddress  
  INTEGER as sPvcForwardPeakCellRate 0..16777215  
  INTEGER as sPvcForwardPeakMode  
  INTEGER as sPvcBackwardPeakCellRate 0..16777215  
  INTEGER as sPvcBackwardPeakMode  
  INTEGER as sPvcForwardSustainableCellRate 0..16777215  
  INTEGER as sPvcForwardMaxBurstSize 0..16777215  
  INTEGER as sPvcForwardSustainableMode  
  INTEGER as sPvcBackwardSustainableCellRate 0..16777215  
  INTEGER as sPvcBackwardMaxBurstSize 0..16777215  
  INTEGER as sPvcBackwardSustainableMode  
  INTEGER as sPvcQoSClass  
  VirtualCircuitIdentifier as sPvcSourceVci  
  VirtualPathIdentifier as sPvcSourceVpi  
  VirtualCircuitIdentifier as sPvcTargetVci  
  VirtualPathIdentifier as sPvcTargetVpi  
  INTEGER as sPvcRetry 0..1000  
  INTEGER as sPvcConnectTime  
  INTEGER as sPvcNumberRetries 0..1000  
  INTEGER as sPvcFailures  
  INTEGER as sPvcAlertFailures  
  Q93bCauseDiag as sPvcCauseDiag  
  INTEGER as sPvcType  
  INTEGER as sPvcCallState  
  INTEGER as sPvcStatus  
  INTEGER as sPvcCauseDiagCode  
  INTEGER as sPvcMulticast  

SvcQ93bStatEntry  
SEQUENCE    
  INTEGER as svcQ93bStatSAP 0..31  
  INTEGER as svcQ93bStatActive 0..16777215  
  INTEGER as svcQ93bStatAccumalative 0..16777215  
  INTEGER as svcQ93bStatCallProcTx 0..16777215  
  INTEGER as svcQ93bStatConnTx 0..16777215  
  INTEGER as svcQ93bStatConnAckTx 0..16777215  
  INTEGER as svcQ93bStatSetupTx 0..16777215  
  INTEGER as svcQ93bStatRelTx 0..16777215  
  INTEGER as svcQ93bStatRelCmpltTx 0..16777215  
  INTEGER as svcQ93bStatRstTx 0..16777215  
  INTEGER as svcQ93bStatRstAckTx 0..16777215  
  INTEGER as svcQ93bStatStatTx 0..16777215  
  INTEGER as svcQ93bStatStatEnqTx 0..16777215  
  INTEGER as svcQ93bStatAddPtyTx 0..16777215  
  INTEGER as svcQ93bStatAddPtyAckTx 0..16777215  
  INTEGER as svcQ93bStatAddPtyRejTx 0..16777215  
  INTEGER as svcQ93bStatDropPtyTx 0..16777215  
  INTEGER as svcQ93bStatDropPtyAckTx 0..16777215  
  INTEGER as svcQ93bStatLstCauseTx 0..16777215  
  INTEGER as svcQ93bStatLstDiagTx 0..16777215  
  INTEGER as svcQ93bStatCallProcRx 0..16777215  
  INTEGER as svcQ93bStatConnRx 0..16777215  
  INTEGER as svcQ93bStatConnAckRx 0..16777215  
  INTEGER as svcQ93bStatSetupRx 0..16777215  
  INTEGER as svcQ93bStatRelRx 0..16777215  
  INTEGER as svcQ93bStatRelCmpltRx 0..16777215  
  INTEGER as svcQ93bStatRstRx 0..16777215  
  INTEGER as svcQ93bStatRstAckRx 0..16777215  
  INTEGER as svcQ93bStatStatRx 0..16777215  
  INTEGER as svcQ93bStatStatEnqRx 0..16777215  
  INTEGER as svcQ93bStatAddPtyRx 0..16777215  
  INTEGER as svcQ93bStatAddPtyAckRx 0..16777215  
  INTEGER as svcQ93bStatAddPtyRejRx 0..16777215  
  INTEGER as svcQ93bStatDropPtyRx 0..16777215  
  INTEGER as svcQ93bStatDropPtyAckRx 0..16777215  
  INTEGER as svcQ93bStatLstCauseRx 0..16777215  
  INTEGER as svcQ93bStatLstDiagRx 0..16777215  
  INTEGER as svcQ93bStatClr  
  Q93bCauseDiag as svcQ93bStatDiagTx  
  Q93bCauseDiag as svcQ93bStatDiagRx  

SvcQsaalStatEntry  
SEQUENCE    
  INTEGER as svcQsaalStatSAP 0..31  
  INTEGER as svcQsaalStatOutSduDisc 0..16777215  
  INTEGER as svcQsaalStatInPduErr 0..16777215  
  INTEGER as svcQsaalStatInPduDisc 0..16777215  
  INTEGER as svcQsaalStatOutPduErr 0..16777215  
  INTEGER as svcQsaalStatOutPduDisc 0..16777215  
  INTEGER as svcQsaalStatBgnTx 0..16777215  
  INTEGER as svcQsaalStatBgakTx 0..16777215  
  INTEGER as svcQsaalStatBgrejTx 0..16777215  
  INTEGER as svcQsaalStatEndTx 0..16777215  
  INTEGER as svcQsaalStatRsTx 0..16777215  
  INTEGER as svcQsaalStatRsakTx 0..16777215  
  INTEGER as svcQsaalStatSdTx 0..16777215  
  INTEGER as svcQsaalStatSdpTx 0..16777215  
  INTEGER as svcQsaalStatPollTx 0..16777215  
  INTEGER as svcQsaalStatStatTx 0..16777215  
  INTEGER as svcQsaalStatUstatTx 0..16777215  
  INTEGER as svcQsaalStatUdTx 0..16777215  
  INTEGER as svcQsaalStatMdTx 0..16777215  
  INTEGER as svcQsaalStatBgnRx 0..16777215  
  INTEGER as svcQsaalStatBgakRx 0..16777215  
  INTEGER as svcQsaalStatBgrejRx 0..16777215  
  INTEGER as svcQsaalStatEndRx 0..16777215  
  INTEGER as svcQsaalStatRsRx 0..16777215  
  INTEGER as svcQsaalStatRsakRx 0..16777215  
  INTEGER as svcQsaalStatSdRx 0..16777215  
  INTEGER as svcQsaalStatSdpRx 0..16777215  
  INTEGER as svcQsaalStatPollRx 0..16777215  
  INTEGER as svcQsaalStatStatRx 0..16777215  
  INTEGER as svcQsaalStatUstatRx 0..16777215  
  INTEGER as svcQsaalStatUdRx 0..16777215  
  INTEGER as svcQsaalStatMdRx 0..16777215  
  INTEGER as svcQsaalStatClr  

SvcCellRateEntry  
SEQUENCE    
  INTEGER as svcCRLinkNo  
  INTEGER as svcPCRCLP01Max  
  INTEGER as svcSCRMax  
  INTEGER as svcMBSMax  

SvcTrafficEntry  
SEQUENCE    
  INTEGER as svcTLinkNo  
  INTEGER as svcCBRallowed  
  INTEGER as svcVBRHallowed  
  INTEGER as svcVBRMallowed  
  INTEGER as svcVBRLUBRallowed  
  INTEGER as svcVBRLUBRsubtractpercent  

CeEntry  
SEQUENCE    
  INTEGER as ceLinkNo  
  INTEGER as ceEnable  
  INTEGER as ceMode  
  INTEGER as cePriority  
  INTEGER as cePvcValid  
  INTEGER as ceDstSlot  
  INTEGER as ceDstLink  
  VirtualPathIdentifier as ceDstVpi  
  VirtualCircuitIdentifier as ceDstVci  
  INTEGER as ceCDV  
  INTEGER as ceCDVMax  
  INTEGER as ceMulticast  
  INTEGER as ceXhInt  

CeStatEntry  
SEQUENCE    
  INTEGER as ceStatPortNo  
  INTEGER as ceStatReset  
  INTEGER as ceStatTxState  
  INTEGER as ceStatRxState  
  Counter as ceTxCnt  
  Counter as ceRxCnt  
  Counter as ceOflCnt  
  Counter as ceUflCnt  
  Counter as ceDisCnt  
  Counter as ceInvCnt  
  Counter as ceResCnt  
  Counter as ceFifoLvlCnt  

VeEntry  
SEQUENCE    
  INTEGER as veLinkNo  
  INTEGER as veEnable  
  INTEGER as veMode  
  INTEGER as vePriority  
  INTEGER as vePvcValid  
  INTEGER as veDstSlot  
  INTEGER as veDstLink  
  VirtualPathIdentifier as veDstVpi  
  VirtualCircuitIdentifier as veDstVci  
  INTEGER as veCDV  
  INTEGER as veCDVMax  
  INTEGER as veMulticast  
  INTEGER as veXhInt  

VeStatEntry  
SEQUENCE    
  INTEGER as veStatPortNo  
  INTEGER as veStatReset  
  INTEGER as veStatTxState  
  INTEGER as veStatRxState  
  Counter as veTxCnt  
  Counter as veRxCnt  
  Counter as veOflCnt  
  Counter as veUflCnt  
  Counter as veDisCnt  
  Counter as veInvCnt  
  Counter as veResCnt  
  Counter as veFifoLvlCnt  

CtrlEntry  
SEQUENCE    
  INTEGER as ctrlIndex  
  INTEGER as ctrlCodecType  
  INTEGER as ctrlCodecAction  
  INTEGER as ctrlCodecReq  
  INTEGER as ctrlCallType  
  INTEGER as ctrlCodecSta  
  INTEGER as ctrlChnlLpbk  
  INTEGER as ctrlFraming  
  INTEGER as ctrlChnlStat  
  INTEGER as ctrlFaultReason  

VidEntry  
SEQUENCE    
  INTEGER as vidIndex  
  INTEGER as vidStandard  
  INTEGER as vidTxVidReq  
  INTEGER as vidRxVidReq  
  INTEGER as vidViewPip  
  INTEGER as vidCompQual  
  Counter as vidEncFrameCount  
  Counter as vidDecFrameCount  
  INTEGER as vidState  
  INTEGER as vidInPresent  
  INTEGER as vidEncBitRate  
  INTEGER as vidDigLpbk  

AudEntry  
SEQUENCE    
  INTEGER as audIndex  
  INTEGER as audState  
  INTEGER as audPrefMode  
  INTEGER as audCommMode  
  INTEGER as audBitRate  
  INTEGER as audMuteInReq  
  INTEGER as audMuteOutReq  
  INTEGER as audMuteOutStat  
  INTEGER as audLpbk  
  INTEGER as audInVol  
  INTEGER as audOutVol  
  INTEGER as audInDelay  
  INTEGER as audOutDelay  
  INTEGER as audFaultReason  

DataEntry  
SEQUENCE    
  INTEGER as dataIndex  
  INTEGER as dataChnlType  
  INTEGER as dataPortSpeed  
  INTEGER as dataPortProt  
  INTEGER as dataHDLCcheck  
  INTEGER as dataChnlStat  
  Counter as dataBytesRcvd  
  Counter as dataBytesSent  
  INTEGER as dataResetStat  

MgmtEntry  
SEQUENCE    
  INTEGER as mgmtIndex  
  DisplayString as mgmtDescr  
  INTEGER as mgmtPortProt  
  INTEGER as mgmtPortSpeed  
  IpAddress as mgmtPortAddress  
  IpAddress as mgmtAddressMask  
  IpAddress as mgmtRemoteAddress  
  INTEGER as mgmtPortStat  
  Counter as mgmtBytesRcvd  
  Counter as mgmtBytesSent  
  INTEGER as mgmtResetStat  

OamEntry  
SEQUENCE    
  INTEGER as oamLinkNo  
  INTEGER as oamSegEndPoint  
  INTEGER as oamVcEndPoint  
  INTEGER as oamAisRdiGeneration  
  INTEGER as oamLastRxType  
  VirtualPathIdentifier as oamLastRxVpi  
  VirtualCircuitIdentifier as oamLastRxVci  
  Counter as oamRxCount  
  INTEGER as oamLastTxType  
  VirtualPathIdentifier as oamLastTxVpi  
  VirtualCircuitIdentifier as oamLastTxVci  
  Counter as oamTxCount  
  INTEGER as oamClearStats  

OamLoopbackEntry  
SEQUENCE    
  INTEGER as oamLoopbackLinkNo  
  VirtualPathIdentifier as oamLoopbackVpi  
  VirtualCircuitIdentifier as oamLoopbackVci  
  INTEGER as oamLoopbackSpan  
  INTEGER as oamLoopbackMaxNumCells  
  INTEGER as oamLoopbackNumCellsSent  
  INTEGER as oamLoopbackTimeOut  
  INTEGER as oamLoopbackActive  
  INTEGER as oamLoopbackResult  
  INTEGER as oamLoopbackLocId  

OamVcaEntry  
SEQUENCE    
  VirtualPathIdentifier as oamVcaVpi  
  VirtualCircuitIdentifier as oamVcaVci  
  INTEGER as oamVcaConnectionType  
  INTEGER as oamVcaVpcEndPoint  
  INTEGER as oamVcaAisRdiGeneration  
  INTEGER as oamVcaAisRdiState  
  INTEGER as oamVcaDefectType  
  INTEGER as oamVcaDefectNode  
  INTEGER as oamVcaDefectSlot  
  INTEGER as oamVcaDefectLink  
  INTEGER as oamVcaTrapEnable  
  INTEGER as oamVcaCC  
  INTEGER as oamVcaCCState  
  INTEGER as oamVcaPM  
  INTEGER as oamVcaPMBlockSize  
  INTEGER as oamVcaPMState  
  INTEGER as oamVcaBkwRptLosCells  
  INTEGER as oamVcaBkwRptMisCells  
  INTEGER as oamVcaBkwRptBip16  
  INTEGER as oamVcaBkwRptSevErr  

OamVcbEntry  
SEQUENCE    
  VirtualPathIdentifier as oamVcbVpi  
  VirtualCircuitIdentifier as oamVcbVci  
  INTEGER as oamVcbConnectionType  
  INTEGER as oamVcbVpcEndPoint  
  INTEGER as oamVcbAisRdiGeneration  
  INTEGER as oamVcbAisRdiState  
  INTEGER as oamVcbDefectType  
  INTEGER as oamVcbDefectNode  
  INTEGER as oamVcbDefectSlot  
  INTEGER as oamVcbDefectLink  
  INTEGER as oamVcbTrapEnable  
  INTEGER as oamVcbCC  
  INTEGER as oamVcbCCState  
  INTEGER as oamVcbPM  
  INTEGER as oamVcbPMBlockSize  
  INTEGER as oamVcbPMState  
  INTEGER as oamVcbBkwRptLosCells  
  INTEGER as oamVcbBkwRptMisCells  
  INTEGER as oamVcbBkwRptBip16  
  INTEGER as oamVcbBkwRptSevErr  

LmiEntry  
SEQUENCE    
  INTEGER as lmiLinkNo  
  VirtualPathIdentifier as lmiVpi  
  VirtualCircuitIdentifier as lmiVci  
  INTEGER as lmiType  
  INTEGER as lmiState  
  INTEGER as lmiFormat  
  E164SUB as lmiPrefix  
  INTEGER as lmiOnOff  
  INTEGER as lmiPollPeriod  
  INTEGER as lmiNoRspDown  
  INTEGER as lmiLinkMgmt  
  INTEGER as lmiConnectivity  
  E164 as lmiPrefixMod  
  E164 as lmiEsi  

LmiNetSideEntry  
SEQUENCE    
  INTEGER as lmiNetSideLinkNo  
  INTEGER as lmiNetSidePrefixId  
  E164SUB as lmiNetSidePrefix  
  INTEGER as lmiNetSidePrefixStatus  

LmiUserSideEntry  
SEQUENCE    
  INTEGER as lmiUserSideLinkNo  
  INTEGER as lmiUserSideAddressId  
  E164SUB as lmiUserSideAddress  
  INTEGER as lmiUserSideAddressStatus  

AlarmStatEntry  
SEQUENCE    
  INTEGER as alrStatSlotNo  
  INTEGER as slotCritStatus  
  INTEGER as slotMajorStatus  
  INTEGER as slotMinorStatus  
  INTEGER as link0CritStatus  
  INTEGER as link0MajorStatus  
  INTEGER as link0MinorStatus  
  INTEGER as link1CritStatus  
  INTEGER as link1MajorStatus  
  INTEGER as link1MinorStatus  
  INTEGER as link2CritStatus  
  INTEGER as link2MajorStatus  
  INTEGER as link2MinorStatus  
  INTEGER as link3CritStatus  
  INTEGER as link3MajorStatus  
  INTEGER as link3MinorStatus  

AlarmACOEntry  
SEQUENCE    
  INTEGER as alrACOslotNo  
  INTEGER as alrACOslotACO  
  INTEGER as alrACOlink0ACO  
  INTEGER as alrACOlink1ACO  
  INTEGER as alrACOlink2ACO  
  INTEGER as alrACOlink3ACO  

UserStatusEntry  
SEQUENCE    
  INTEGER as userInputNo  
  INTEGER as userInputEnable  
  INTEGER as userInputTrapEnable  
  DisplayString as userInputTrapDesc  
  INTEGER as userInputActiveState  
  INTEGER as userInputAlrClass  
  INTEGER as userInputStatus  

CacPerLinkEntry  
SEQUENCE    
  INTEGER as cacLinkNo  
  Gauge as cacLinkSumE10  
  Gauge as cacLinkSumE1T  
  INTEGER as cacLinkObfPvc1  
  INTEGER as cacLinkObfSvc1  
  Gauge as cacLinkSumE20  
  Gauge as cacLinkSumE2T  
  INTEGER as cacLinkObfPvc2  
  INTEGER as cacLinkObfSvc2  
  INTEGER as cacLinkTotalBwScrPcr  
  INTEGER as cacCurrentLinkUsage  
  INTEGER as cacMaxLinkUsage  
  INTEGER as cacLinkReset  
  INTEGER as cacLinkVersion  
  INTEGER as cacLinkEnable  
  INTEGER as cacLinkSignalMode  
  INTEGER as cacLinkState  

CacPerSapEntry  
SEQUENCE    
  INTEGER as cacSapNo  
  Gauge as cacSapSumE1T  
  Gauge as cacSapSumE2T  
  INTEGER as cacSapTotalBwScrPcr  
  INTEGER as cacCurrentSapUsage  
  INTEGER as cacMaxSapUsage  
  INTEGER as cacSapReset