DVB-MGTR101290-MIB

File: DVB-MGTR101290-MIB.mib (342672 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC

Imported symbols

OBJECT-GROUP MODULE-COMPLIANCE NOTIFICATION-GROUP
enterprises Integer32 Unsigned32
Counter32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE TruthValue DateAndTime
DisplayString RowStatus TEXTUAL-CONVENTION

Defined Objects

dvb 1.3.6.1.4.1.2696
OBJECT IDENTIFIER    

mg 1.3.6.1.4.1.2696.3
OBJECT IDENTIFIER    

tr101290 1.3.6.1.4.1.2696.3.2
DVB Measurement Group MIB to support TR 101 290. This tr101290 module contains measurements defined in TR 101 290.
MODULE-IDENTITY    

tr101290Objects 1.3.6.1.4.1.2696.3.2.1
OBJECT IDENTIFIER    

tr101290Control 1.3.6.1.4.1.2696.3.2.1.1
OBJECT IDENTIFIER    

controlNow 1.3.6.1.4.1.2696.3.2.1.1.1
The current date and time at the location of the measurement equipment. It is highly desirable that the offset from UTC should be included. It is possible to set the time and date through this object, but it is expected that most systems will incorporate a more accurate method for doing this.
OBJECT-TYPE    
  DateAndTime  

controlEventPersistence 1.3.6.1.4.1.2696.3.2.1.1.2
The persistence timer used with Event errors. An Event error test remains in the 'fail' state for this length of time after the occurrence of the Event.
OBJECT-TYPE    
  FloatingPoint  

controlRFSystemTable 1.3.6.1.4.1.2696.3.2.1.1.3
Table which controls the RF modulation expected to be received on each input.
OBJECT-TYPE    
  SEQUENCE OF  
    ControlRFSystemEntry

controlRFSystemEntry 1.3.6.1.4.1.2696.3.2.1.1.3.1
Row specification
OBJECT-TYPE    
  ControlRFSystemEntry  

rfSystemInputNumber 1.3.6.1.4.1.2696.3.2.1.1.3.1.1
RF input whose mode of operation is to be set
OBJECT-TYPE    
  InputNumber  

rfSystemDelivery 1.3.6.1.4.1.2696.3.2.1.1.3.1.2
The type of signal the instrument should expect at its input.
OBJECT-TYPE    
  DeliverySystemType  

controlSynchronizationTable 1.3.6.1.4.1.2696.3.2.1.1.4
Table reserved for future specification of synchronized timing.
OBJECT-TYPE    
  SEQUENCE OF  
    ControlSynchronizationEntry

controlSynchronizationEntry 1.3.6.1.4.1.2696.3.2.1.1.4.1
Row specification
OBJECT-TYPE    
  ControlSynchronizationEntry  

controlSynchronizationInputNumber 1.3.6.1.4.1.2696.3.2.1.1.4.1.1
Transport Stream number to which the objects in this row apply.
OBJECT-TYPE    
  InputNumber  

controlSynchronizedTime 1.3.6.1.4.1.2696.3.2.1.1.4.1.2
This object is reserved pending future standardisation of timestamping of Transport Streams.
OBJECT-TYPE    
  FloatingPoint  

tr101290Trap 1.3.6.1.4.1.2696.3.2.1.2
OBJECT IDENTIFIER    

trapPrefix 1.3.6.1.4.1.2696.3.2.1.2.0
OBJECT IDENTIFIER    

testFailTrap 1.3.6.1.4.1.2696.3.2.1.2.0.1
This trap is sent when a test which is not associated with a measurement fails. This trap is triggered by the transition of the '...State' or '...TestState' object associated with the test to the 'fail' state from any other state. Transmission of the trap is subject to rate control and to the enable status of each test.
NOTIFICATION-TYPE    
  trapControlOID  
  trapControlGenerationTime  
  trapControlFailureSummary  
  trapInput  

measurementFailTrap 1.3.6.1.4.1.2696.3.2.1.2.0.2
Trap which is sent when a test which is associated with a measurement fails. This trap is triggered by the transition of the '...State' or '...TestState' object associated with the test to the 'fail' state from any other state. Transmission of the trap is subject to rate control and to the enable status of each test.
NOTIFICATION-TYPE    
  trapControlOID  
  trapControlGenerationTime  
  trapControlMeasurementValue  
  trapControlFailureSummary  
  trapInput  

measurementUnknownTrap 1.3.6.1.4.1.2696.3.2.1.2.0.3
Trap which is sent when a measurement value becomes unavailable. This trap is triggered by the transition of the '...MeasurementState' object associated with the measurement to the 'unknown' state from any other state. Transmission of the trap is subject to rate control.
NOTIFICATION-TYPE    
  trapControlOID  
  trapControlGenerationTime  
  trapControlFailureSummary  
  trapInput  

trapControlTable 1.3.6.1.4.1.2696.3.2.1.2.1
Table of trap control information for each input
OBJECT-TYPE    
  SEQUENCE OF  
    TrapControlEntry

trapControlEntry 1.3.6.1.4.1.2696.3.2.1.2.1.1
Row specification
OBJECT-TYPE    
  TrapControlEntry  

trapControlInputNumber 1.3.6.1.4.1.2696.3.2.1.2.1.1.1
Each Transport Stream input has separate trap control parameters. This object identifies the Transport Stream input to which the trap control parameters apply
OBJECT-TYPE    
  InputNumber  

trapControlOID 1.3.6.1.4.1.2696.3.2.1.2.1.1.2
In the case of a testFailTrap or a measurementFailTrap, this object holds the OID of the '...State' or '...TestState' object whose transition to 'fail' has triggered the trap. In the case of a measurementUnknownTrap, this object holds the OID of the '...MeasurementState' object whose transition to 'unknown' has triggered the trap. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

trapControlGenerationTime 1.3.6.1.4.1.2696.3.2.1.2.1.1.3
In the case of a testFailTrap or a measurementFailTrap, at the moment when the trap is generated, the value of the '...LatestError' object associated with the test which caused the trap is copied here. In the case of a measurementUnknownTrap, the time at which the measurement became unknown is copied here. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading.
OBJECT-TYPE    
  DateAndTime  

trapControlMeasurementValue 1.3.6.1.4.1.2696.3.2.1.2.1.1.4
At the moment when a measurementFailTrap is generated, the value of this object is set from the '...Value' object associated with the measurement which caused the trap. Where a measurement returns multiple values, the value which is copied here is the one which is compared with the threshold(s) to generate the test result. The measurement units are the same as those of the source object. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading.
OBJECT-TYPE    
  FloatingPoint  

trapControlRateStatus 1.3.6.1.4.1.2696.3.2.1.2.1.1.5
This object is used for rate control of traps, preventing overload of the management network by transmission of an excessive number of traps. The value 'disabled' means that traps are never sent. The value 'enabled' means that a trap will be sent when triggered. When a trap is sent, the agent changes the value of this object to 'enabledThrottled'. In this state the agent will not send any more traps. The agent automatically changes the value back to 'enabled' when the time specified by trapControlPeriod expires. A management application may set the value to 'enabled' at any time, but must never set the value to 'enabledThrottled'. This single status applies to all the trap types, so for example if an agent sends a testFailTrap it will not send a measurementFailTrap until the trapControlPeriod expires.
OBJECT-TYPE    
  RateStatus  

trapControlPeriod 1.3.6.1.4.1.2696.3.2.1.2.1.1.6
An agent will ensure that the interval between sending traps is no shorter than this time period. The management system can override this by setting trapControlRateStatus back to 'enabled' within the time period.
OBJECT-TYPE    
  Unsigned32 0..3600000  

trapControlFailureSummary 1.3.6.1.4.1.2696.3.2.1.2.1.1.7
This bit string contains a summary of all the test failures. If the bit for the test is set to one, that test is in a fail state. When a trap is being generated, the agent should ensure that this information is as up to date as possible, without causing undue delay in sending the trap.
OBJECT-TYPE    
  TestSummary  

trapInput 1.3.6.1.4.1.2696.3.2.1.2.2
The Transport Stream input whose change triggered the current trap. This information can also be obtained by analysing the trapControlOID, but trapInput provides the information directly. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading.
OBJECT-TYPE    
  InputNumber  

tr101290Capability 1.3.6.1.4.1.2696.3.2.1.3
OBJECT IDENTIFIER    

capabilityMIBRevision 1.3.6.1.4.1.2696.3.2.1.3.1
The capabilities of the agent are expressed in relation to a specific revision of the tr101290 MIB module. The date and time here must exactly match one of the revision dates in the MODULE-IDENTITY section of the MIB.
OBJECT-TYPE    
  DateAndTime  

capabilityTS 1.3.6.1.4.1.2696.3.2.1.3.5
OBJECT IDENTIFIER    

capabilityTSGroup 1.3.6.1.4.1.2696.3.2.1.3.5.1
Specifies the overall availability of the Transport Stream group of tests and measurements, tr101290TS.
OBJECT-TYPE    
  GroupAvailability  

capabilityTSTable 1.3.6.1.4.1.2696.3.2.1.3.5.2
Specifies the individual availability of the Transport Stream group of tests and measurements, tr101290TS.
OBJECT-TYPE    
  SEQUENCE OF  
    CapabilityTSEntry

capabilityTSEntry 1.3.6.1.4.1.2696.3.2.1.3.5.2.1
Row specification
OBJECT-TYPE    
  CapabilityTSEntry  

capabilityTSOID 1.3.6.1.4.1.2696.3.2.1.3.5.2.1.1
The object identifier of a specific test/measurement. The object identifier of the object within the table whose SYNTAX is 'TestState' is used to identify the test/measurement. Table index components of the object identifier are set to zero, except for those which identify specific tests/measurements. Such index objects always have a syntax which begins 'Index...' in this MIB.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

capabilityTSAvailability 1.3.6.1.4.1.2696.3.2.1.3.5.2.1.2
The availability of a specific test or measurement
OBJECT-TYPE    
  Availability  

capabilityTSPollInterval 1.3.6.1.4.1.2696.3.2.1.3.5.2.1.3
Indicates the interval between updates of the information supplied by this object.
OBJECT-TYPE    
  PollingInterval  

capabilityCableSat 1.3.6.1.4.1.2696.3.2.1.3.6
OBJECT IDENTIFIER    

capabilityCableSatGroup 1.3.6.1.4.1.2696.3.2.1.3.6.1
Specifies the overall availability of the cable and satellite group of tests and measurements, tr101290CableSat.
OBJECT-TYPE    
  GroupAvailability  

capabilityCableSatTable 1.3.6.1.4.1.2696.3.2.1.3.6.2
Specifies the individual availability of the cable and satellite group of tests and measurements, tr101290CableSat.
OBJECT-TYPE    
  SEQUENCE OF  
    CapabilityCableSatEntry

capabilityCableSatEntry 1.3.6.1.4.1.2696.3.2.1.3.6.2.1
Row specification
OBJECT-TYPE    
  CapabilityCableSatEntry  

capabilityCableSatOID 1.3.6.1.4.1.2696.3.2.1.3.6.2.1.1
The object identifier of a specific test/measurement. The object identifier of the object within the table whose SYNTAX is 'TestState' is used to identify the test/measurement. Table index components of the object identifier are set to zero, except for those which identify specific tests/measurements. Such index objects always have a syntax which begins 'Index...' in this MIB.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

capabilityCableSatAvailability 1.3.6.1.4.1.2696.3.2.1.3.6.2.1.2
The availability of a specific test or measurement
OBJECT-TYPE    
  Availability  

capabilityCableSatPollInterval 1.3.6.1.4.1.2696.3.2.1.3.6.2.1.3
Indicates the interval between updates of the information supplied by this object.
OBJECT-TYPE    
  PollingInterval  

capabilityCable 1.3.6.1.4.1.2696.3.2.1.3.7
OBJECT IDENTIFIER    

capabilityCableGroup 1.3.6.1.4.1.2696.3.2.1.3.7.1
Specifies the overall availability of the cable group of tests and measurements, tr101290Cable.
OBJECT-TYPE    
  GroupAvailability  

capabilityCableTable 1.3.6.1.4.1.2696.3.2.1.3.7.2
Specifies the individual availability of the cable group of tests and measurements, tr101290Cable.
OBJECT-TYPE    
  SEQUENCE OF  
    CapabilityCableEntry

capabilityCableEntry 1.3.6.1.4.1.2696.3.2.1.3.7.2.1
Row specification
OBJECT-TYPE    
  CapabilityCableEntry  

capabilityCableOID 1.3.6.1.4.1.2696.3.2.1.3.7.2.1.1
The object identifier of a specific test/measurement. The object identifier of the object within the table whose SYNTAX is 'TestState' is used to identify the test/measurement. Table index components of the object identifier are set to zero, except for those which identify specific tests/measurements. Such index objects always have a syntax which begins 'Index...' in this MIB.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

capabilityCableAvailability 1.3.6.1.4.1.2696.3.2.1.3.7.2.1.2
The availability of a specific test or measurement
OBJECT-TYPE    
  Availability  

capabilityCablePollInterval 1.3.6.1.4.1.2696.3.2.1.3.7.2.1.3
Indicates the interval between updates of the information supplied by this object.
OBJECT-TYPE    
  PollingInterval  

capabilitySatellite 1.3.6.1.4.1.2696.3.2.1.3.8
OBJECT IDENTIFIER    

capabilitySatelliteGroup 1.3.6.1.4.1.2696.3.2.1.3.8.1
Specifies the overall availability of the satellite group of tests and measurements, tr101290Satellite.
OBJECT-TYPE    
  GroupAvailability  

capabilitySatelliteTable 1.3.6.1.4.1.2696.3.2.1.3.8.2
Specifies the individual availability of the satellite group of tests and measurements, tr101290Satellite.
OBJECT-TYPE    
  SEQUENCE OF  
    CapabilitySatelliteEntry

capabilitySatelliteEntry 1.3.6.1.4.1.2696.3.2.1.3.8.2.1
Row specification
OBJECT-TYPE    
  CapabilitySatelliteEntry  

capabilitySatelliteOID 1.3.6.1.4.1.2696.3.2.1.3.8.2.1.1
The object identifier of a specific test/measurement. The object identifier of the object within the table whose SYNTAX is 'TestState' is used to identify the test/measurement. Table index components of the object identifier are set to zero, except for those which identify specific tests/measurements. Such index objects always have a syntax which begins 'Index...' in this MIB.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

capabilitySatelliteAvailability 1.3.6.1.4.1.2696.3.2.1.3.8.2.1.2
The availability of a specific test or measurement
OBJECT-TYPE    
  Availability  

capabilitySatellitePollInterval 1.3.6.1.4.1.2696.3.2.1.3.8.2.1.3
Indicates the interval between updates of the information supplied by this object.
OBJECT-TYPE    
  PollingInterval  

capabilityTerrestrial 1.3.6.1.4.1.2696.3.2.1.3.9
OBJECT IDENTIFIER    

capabilityTerrestrialGroup 1.3.6.1.4.1.2696.3.2.1.3.9.1
Specifies the overall availability of the terrestrial group of tests and measurements, tr101290Terrestrial.
OBJECT-TYPE    
  GroupAvailability  

capabilityTerrestrialTable 1.3.6.1.4.1.2696.3.2.1.3.9.2
Specifies the individual availability of the terrestrial group of tests and measurements, tr101290Terrestrial.
OBJECT-TYPE    
  SEQUENCE OF  
    CapabilityTerrestrialEntry

capabilityTerrestrialEntry 1.3.6.1.4.1.2696.3.2.1.3.9.2.1
Row specification
OBJECT-TYPE    
  CapabilityTerrestrialEntry  

capabilityTerrestrialOID 1.3.6.1.4.1.2696.3.2.1.3.9.2.1.1
The object identifier of a specific test/measurement. The object identifier of the object within the table whose SYNTAX is 'TestState' is used to identify the test/measurement. Table index components of the object identifier are set to zero, except for those which identify specific tests/measurements. Such index objects always have a syntax which begins 'Index...' in this MIB.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

capabilityTerrestrialAvailability 1.3.6.1.4.1.2696.3.2.1.3.9.2.1.2
The availability of a specific test or measurement
OBJECT-TYPE    
  Availability  

capabilityTerrestrialPollInterval 1.3.6.1.4.1.2696.3.2.1.3.9.2.1.3
Indicates the interval between updates of the information supplied by this object.
OBJECT-TYPE    
  PollingInterval  

tr101290TS 1.3.6.1.4.1.2696.3.2.1.5
OBJECT IDENTIFIER    

tsTests 1.3.6.1.4.1.2696.3.2.1.5.2
OBJECT IDENTIFIER    

tsTestsSummaryTable 1.3.6.1.4.1.2696.3.2.1.5.2.2
The tsTestsSummaryTable provides access to the state of all of the Transport Stream tests enumerated in IndexTransportStreamTest. The status relates to the whole Transport Stream. In the case of tests which have a status per PID, the tsTestsSummaryTable gives the 'worst' status across all the PIDs and the status for each PID is available in tsTestsPIDTable.
OBJECT-TYPE    
  SEQUENCE OF  
    TsTestsSummaryEntry

tsTestsSummaryEntry 1.3.6.1.4.1.2696.3.2.1.5.2.2.1
Row specification
OBJECT-TYPE    
  TsTestsSummaryEntry  

tsTestsSummaryInputNumber 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.1
Transport Stream on which the test is made
OBJECT-TYPE    
  InputNumber  

tsTestsSummaryTestNumber 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.2
Specifies the test, see definition of IndexTransportStreamTest. Rows in the table exist only for tests which are actually implemented by the measuring equipment.
OBJECT-TYPE    
  IndexTransportStreamTest  

tsTestsSummaryState 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.3
This gives the overall pass/fail state of the test. For tests which have a state per PID, tsTestsSummaryState contains the highest numeric value of all the tsTestsPIDState objects for the test.
OBJECT-TYPE    
  TestState  

tsTestsSummaryEnable 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.4
Determines whether this test and associated traps are enabled. Setting tsTestsSummaryEnable affects tsTestsPIDEnable in tsTestsPIDTable. When tsTestsSummaryEnable is set, all existing instances of tsTestsPIDEnable are set to the same value. Any new rows in tsTestsPIDTable which are created will also have this value for tsTestsPIDEnable (unless the row is created by explicitly setting the value of tsTestsPIDEnable).
OBJECT-TYPE    
  Enable  

tsTestsSummaryCounter 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.5
Count of the number of times this error has occurred. For Status errors this is the number of times the TestState has entered the fail state from some other state. For Error events this is the total number of events; the persistence timer is not taken into account by the counter.
OBJECT-TYPE    
  Counter32  

tsTestsSummaryCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.6
Provides the last time at which there was a discontinuity in the tsTestsSummaryCounter object.
OBJECT-TYPE    
  DateAndTime  

tsTestsSummaryCounterReset 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.7
tsTestsSummaryCounter is reset to zero and tsTestsSummaryCounterDiscontinuity is set to the current time if this object is set to 'true'. This object has no effect on the tsTestsPIDCounter objects.
OBJECT-TYPE    
  TruthValue  

tsTestsSummaryLatestError 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.8
The timestamp at the most recent occurrence of the error. For Status errors this is the most recent time the TestState entered the fail state from some other state. For Error events this is the most recent occurrence; the persistence timer is not taken into account.
OBJECT-TYPE    
  DateAndTime  

tsTestsSummaryActiveTime 1.3.6.1.4.1.2696.3.2.1.5.2.2.1.9
The total time when it has been possible to evaluate this test.
OBJECT-TYPE    
  ActiveTime  

tsTestsPIDTable 1.3.6.1.4.1.2696.3.2.1.5.2.3
The tsTestsPIDTable provides access to the state of those Transport Stream tests enumerated in IndexTransportStreamTest which relate to individual PIDs. These tests are: 1.4 Continuity_count_error 1.5.a PMT_error_2 1.6 PID_error 2.3.a PCR_repetition_error 2.3.b PCR_discontinuity_indicator_error 2.4 PCR_accuracy_error 2.5 PTS_error 3.3 Buffer_error 3.4.a Unreferenced_PID
OBJECT-TYPE    
  SEQUENCE OF  
    TsTestsPIDEntry

tsTestsPIDEntry 1.3.6.1.4.1.2696.3.2.1.5.2.3.1
Row specification
OBJECT-TYPE    
  TsTestsPIDEntry  

tsTestsPIDInputNumber 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.1
Transport Stream on which the test is made
OBJECT-TYPE    
  InputNumber  

tsTestsPIDPID 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.2
PID (plus one) on which the test is made
OBJECT-TYPE    
  PIDPlusOne  

tsTestsPIDTestNumber 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.3
Specifies the test, see definition of IndexTransportStreamTest. Rows in the table exist only for tests which are actually implemented by the measuring equipment.
OBJECT-TYPE    
  IndexTransportStreamTest  

tsTestsPIDRowStatus 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.4
This is used by the manager to create and delete rows in tsTestsPIDTable. The agent automatically creates rows for PID/test combinations where there are errors to report.
OBJECT-TYPE    
  RowStatus  

tsTestsPIDState 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.5
This gives the overall pass/fail state of the test
OBJECT-TYPE    
  TestState  

tsTestsPIDEnable 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.6
Determines whether this test and associated traps are enabled. When a trap triggering condition arises for a per PID test, this object alone is used to determine whether a trap will be generated, without any reference to tsTestsSummaryEnable.
OBJECT-TYPE    
  Enable  

tsTestsPIDCounter 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.7
Count of the number of times this error has occurred. For Status errors this is the number of times the TestState has entered the fail state from some other state. For Error events this is the total number of events; the persistence timer is not taken into account by the counter.
OBJECT-TYPE    
  Counter32  

tsTestsPIDCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.8
Provides the last time at which there was a discontinuity in the tsTestsSummaryCounter object.
OBJECT-TYPE    
  DateAndTime  

tsTestsPIDCounterReset 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.9
tsTestsPIDCounter is reset to zero and tsTestsPIDCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsTestsPIDLatestError 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.10
The timestamp at the most recent occurrence of the error. For Status errors this is the most recent time the TestState entered the fail state from some other state. For Error events this is the most recent occurrence; the persistence timer is not taken into account.
OBJECT-TYPE    
  DateAndTime  

tsTestsPIDActiveTime 1.3.6.1.4.1.2696.3.2.1.5.2.3.1.11
The total time when it has been possible to evaluate this test.
OBJECT-TYPE    
  ActiveTime  

tsTestsPreferences 1.3.6.1.4.1.2696.3.2.1.5.2.100
OBJECT IDENTIFIER    

tsTestsPreferencesTable 1.3.6.1.4.1.2696.3.2.1.5.2.100.1
This table contains measurement thresholds and other configuration information that is applied on a per Transport Stream basis.
OBJECT-TYPE    
  SEQUENCE OF  
    TsTestsPreferencesEntry

tsTestsPreferencesEntry 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1
Row specification
OBJECT-TYPE    
  TsTestsPreferencesEntry  

tsTestsPrefInputNumber 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsTestsPrefTransitionDuration 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.2
Various tests, including CAT_error (2.6) and Unreferenced_PID (3.4) must take into account that short transition periods can exist where the state of the SI and PSI information is inconsistent with the state of the stream. These transitions should not cause error indications. This parameter specifies the period which must be allowed for transition states.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPATSectionIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.3
Maximum repetition interval for PAT sections.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPMTSectionIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.4
Maximum repetition interval for PMT sections.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefReferredIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.5
Maximum permitted interval between the arrival of consecutive packets for all PIDs. When the value of this object is set, the value of tsTestsPrefPIDReferredIntervalMax is changed for every PID. The value of this object is also used as a default for tsTestsPrefPIDReferredIntervalMax when a new row is created in tsTestsPreferencesPIDTable.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPCRIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.6
Maximum permitted interval between PCR arrival times on each PCR PID.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPCRDiscontinuityMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.7
Maximum permitted difference between two consecutive PCR values.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPCRInaccuracyMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.8
Maximum permitted PCR inaccuracy. An error is indicated if the PCR inaccuracy is outside the range: [-tsTestsPrefPCRInaccuracyMax .. +tsTestsPrefPCRInaccuracyMax].
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefPTSIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.9
Maximum permitted PTS repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefNITActualIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.10
Maximum permitted NIT_actual section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefNITActualIntervalMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.11
Minimum permitted NIT_actual section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefNITOtherIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.12
Maximum permitted NIT_other section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSIGapMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.13
Minimum permitted gap between packets containing sections.
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefNITTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.14
Maximum permitted NIT table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefBATTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.15
Maximum permitted BAT table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSDTActualTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.16
Maximum permitted SDT actual transport stream table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSDTOtherTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.17
Maximum permitted SDT other transport stream table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITPFActualTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.18
Maximum permitted EIT Present/Following actual transport stream table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITPFOtherTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.19
Maximum permitted EIT Present/Following other transport stream table repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITSActualNearTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.20
Maximum permitted EIT Schedule actual transport stream table repetition interval for the near future (the next 8 days for satellite and cable, the next day for terrestrial).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITSActualFarTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.21
Maximum permitted EIT Schedule actual transport stream table repetition interval for the far future (beyond the next 8 days for satellite and cable, beyond the next day for terrestrial).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITSOtherNearTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.22
Maximum permitted EIT Schedule other transport stream table repetition interval for the near future (the next 8 days for satellite and cable, the next day for terrestrial).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITSOtherFarTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.23
Maximum permitted EIT Schedule other transport stream table repetition interval for the far future (beyond the next 8 days for satellite and cable, beyond the next day for terrestrial).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefTxTTableIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.24
Maximum permitted TDT and TOT table repetition intervals
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSDTActualIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.25
Maximum permitted SDT_actual section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSDTActualIntervalMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.26
Minimum permitted SDT_actual section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefSDTOtherIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.27
Maximum permitted SDT_other section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITActualIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.28
Maximum permitted EIT_actual section repetition interval (applies to both present and following sections).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITActualIntervalMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.29
Minimum permitted EIT_actual section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefEITOtherIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.30
Maximum permitted EIT_other section repetition interval (applies to both present and following sections).
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefRSTIntervalMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.31
Minimum permitted RST section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefTDTIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.32
Maximum permitted TDT section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPrefTDTIntervalMin 1.3.6.1.4.1.2696.3.2.1.5.2.100.1.1.33
Minimum permitted TDT section repetition interval
OBJECT-TYPE    
  FloatingPoint  

tsTestsPreferencesPIDTable 1.3.6.1.4.1.2696.3.2.1.5.2.100.2
This table contains measurement thresholds and other configuration information that is applied on a per PID per Transport Stream basis.
OBJECT-TYPE    
  SEQUENCE OF  
    TsTestsPreferencesPIDEntry

tsTestsPreferencesPIDEntry 1.3.6.1.4.1.2696.3.2.1.5.2.100.2.1
Description.
OBJECT-TYPE    
  TsTestsPreferencesPIDEntry  

tsTestsPrefPIDInputNumber 1.3.6.1.4.1.2696.3.2.1.5.2.100.2.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsTestsPrefPIDPID 1.3.6.1.4.1.2696.3.2.1.5.2.100.2.1.2
PID to which these preferences apply
OBJECT-TYPE    
  PIDPlusOne  

tsTestsPrefPIDRowStatus 1.3.6.1.4.1.2696.3.2.1.5.2.100.2.1.3
This object is used to manage the rows in this table.
OBJECT-TYPE    
  RowStatus  

tsTestsPrefPIDReferredIntervalMax 1.3.6.1.4.1.2696.3.2.1.5.2.100.2.1.4
Maximum permitted interval between the arrival of consecutive packets of this PID. The default value for this object is the current value of tsTestsPrefReferredIntervalMax for the same input.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurements 1.3.6.1.4.1.2696.3.2.1.5.4
OBJECT IDENTIFIER    

tsPcrMeasurementTable 1.3.6.1.4.1.2696.3.2.1.5.4.1
This table makes available the PCR_FO, PCR_DR, PCR_OJ and PCR_AC measurements.
OBJECT-TYPE    
  SEQUENCE OF  
    TsPcrMeasurementEntry

tsPcrMeasurementEntry 1.3.6.1.4.1.2696.3.2.1.5.4.1.1
Row specification
OBJECT-TYPE    
  TsPcrMeasurementEntry  

tsPcrMeasurementInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.1
Input on which the measurement is made
OBJECT-TYPE    
  InputNumber  

tsPcrMeasurementPID 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.2
PID (plus one) in the Transport Stream carrying (or expected to carry) PCRs.
OBJECT-TYPE    
  PIDPlusOne  

tsPcrMeasurementNumber 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.3
This selects one of the four PCR measurements
OBJECT-TYPE    
  IndexPCRMeasurement  

tsPcrMeasurementRowStatus 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.4
This object is used by the manager to create and delete rows in the table. The agent automatically creates rows for PIDs where it detects the presence of a PCR.
OBJECT-TYPE    
  RowStatus  

tsPcrMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.5
This gives the overall pass/fail state of the threshold test on this measurement
OBJECT-TYPE    
  TestState  

tsPcrMeasurementEnable 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.6
Determines whether this test and associated traps are enabled.
OBJECT-TYPE    
  Enable  

tsPcrMeasurementCounter 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.7
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

tsPcrMeasurementCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.8
Provides the last time at which there was a discontinuity in the tsPcrMeasurementCounter object.
OBJECT-TYPE    
  DateAndTime  

tsPcrMeasurementCounterReset 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.9
tsPcrMeasurementCounter is reset to zero and tsPcrMeasurementCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsPcrMeasurementLatestError 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.10
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

tsPcrMeasurementActiveTime 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.11
The total time when it has been possible to make this measurement
OBJECT-TYPE    
  ActiveTime  

tsPcrMeasurementMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.12
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

tsPcrMeasurementValue 1.3.6.1.4.1.2696.3.2.1.5.4.1.1.13
The units for the measured value depend on the measurement: PCR_FO Hz PCR_DR Hz/s Values for PCR_OJ and PCR_AC are not provided as they occur too quickly to be usefully retrieved via SNMP. For these measurements, the MeasurementState is always 'unknown'. However, the threshold tests are expected to work correctly for these measurements.
OBJECT-TYPE    
  FloatingPoint  

bitRate 1.3.6.1.4.1.2696.3.2.1.5.4.2
OBJECT IDENTIFIER    

tsTransportStreamBitRateTable 1.3.6.1.4.1.2696.3.2.1.5.4.2.1
Bit rates for each complete Transport Stream
OBJECT-TYPE    
  SEQUENCE OF  
    TsTransportStreamBitRateEntry

tsTransportStreamBitRateEntry 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1
Row specification
OBJECT-TYPE    
  TsTransportStreamBitRateEntry  

tsTransportStreamBitRateInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

tsTransportStreamBitRateState 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.2
This gives the overall pass/fail state of the threshold test on this measurement
OBJECT-TYPE    
  TestState  

tsTransportStreamBitRateEnable 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

tsTransportStreamBitRateCounter 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

tsTransportStreamBitRateCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.5
Provides the last time at which there was a discontinuity in the tsTransportStreamBitRateCounterobject.
OBJECT-TYPE    
  DateAndTime  

tsTransportStreamBitRateCounterReset 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.6
tsTransportStreamBitRateCounteris reset to zero and tsTransportStreamBitRateCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsTransportStreamBitRateLatestError 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

tsTransportStreamBitRateActiveTime 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

tsTransportStreamBitRateMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

tsTransportStreamBitRateValue 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.10
The overall Transport Stream bit rate
OBJECT-TYPE    
  FloatingPoint  

tsTransportStreamBitRateNomenclature 1.3.6.1.4.1.2696.3.2.1.5.4.2.1.1.11
Standardised description of the method of measurement of the bitrate, for example 'bit/s @MGB2'
OBJECT-TYPE    
  DisplayString  

tsServiceBitRateTable 1.3.6.1.4.1.2696.3.2.1.5.4.2.2
Bit rates for each service/program within each Transport Stream. The table is sparse, in that only services mentioned in the PMT will be present. The bit rate of a service is the sum of the bit rates of the elementary_PID's in its PMT and the CA_PID's in any CA_descriptors in its PMT (ECMs). The bit rate of the PMT itself is excluded. The bit rate of the PCR_PID is excluded unless the PCR_PID is also one of the elementary_PID's in the PMT.
OBJECT-TYPE    
  SEQUENCE OF  
    TsServiceBitRateEntry

tsServiceBitRateEntry 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1
Row specification
OBJECT-TYPE    
  TsServiceBitRateEntry  

tsServiceBitRateInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

tsServiceBitRateService 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.2
The program_number/service_id to which the information in the rest of the row applies.
OBJECT-TYPE    
  ServiceId  

tsServiceBitRateRowStatus 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.3
This is used by the manager to create and delete rows in the table. The agent will automatically create rows for services it finds in the PMT.
OBJECT-TYPE    
  RowStatus  

tsServiceBitRateState 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.4
This gives the overall pass/fail state of the threshold test on this measurement
OBJECT-TYPE    
  TestState  

tsServiceBitRateEnable 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.5
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

tsServiceBitRateCounter 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.6
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

tsServiceBitRateCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.7
Provides the last time at which there was a discontinuity in the tsServiceBitRateCounter object.
OBJECT-TYPE    
  DateAndTime  

tsServiceBitRateCounterReset 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.8
tsServiceBitRateCounter is reset to zero and tsServiceBitRateCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsServiceBitRateLatestError 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.9
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

tsServiceBitRateActiveTime 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.10
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

tsServiceBitRateMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.11
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

tsServiceBitRateValue 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.12
Overall bit rate for the service
OBJECT-TYPE    
  FloatingPoint  

tsServiceBitRateNomenclature 1.3.6.1.4.1.2696.3.2.1.5.4.2.2.1.13
Standardised description of the method of measurement of the bitrate, for example 'bit/s @MGB2'
OBJECT-TYPE    
  DisplayString  

tsPIDBitRateTable 1.3.6.1.4.1.2696.3.2.1.5.4.2.3
Bit rates for each PID within each Transport Stream. The table is sparse, in that only PIDs whose bit rate is currently greater than zero will be present in the table. This allows for faster traversal of the table to build up a list of PID bit rates.
OBJECT-TYPE    
  SEQUENCE OF  
    TsPIDBitRateEntry

tsPIDBitRateEntry 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1
Row specification
OBJECT-TYPE    
  TsPIDBitRateEntry  

tsPIDBitRateInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

tsPIDBitRatePID 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.2
PID whose bit rate is being measured (plus one)
OBJECT-TYPE    
  PIDPlusOne  

tsPIDBitRateRowStatus 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.3
This is used by the manager to create and delete rows in the table. The agent will automatically create rows for PIDs whose bit rate is non-zero.
OBJECT-TYPE    
  RowStatus  

tsPIDBitRateState 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.4
This gives the overall pass/fail state of the threshold test on this measurement
OBJECT-TYPE    
  TestState  

tsPIDBitRateEnable 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.5
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

tsPIDBitRateCounter 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.6
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

tsPIDBitRateCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.7
Provides the last time at which there was a discontinuity in the tsPIDBitRateCounter object.
OBJECT-TYPE    
  DateAndTime  

tsPIDBitRateCounterReset 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.8
tsPIDBitRateCounter is reset to zero and tsPIDBitRateCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsPIDBitRateLatestError 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.9
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

tsPIDBitRateActiveTime 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.10
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

tsPIDBitRateMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.11
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

tsPIDBitRateValue 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.12
Bit rate for the PID.
OBJECT-TYPE    
  FloatingPoint  

tsPIDBitRateNomenclature 1.3.6.1.4.1.2696.3.2.1.5.4.2.3.1.13
Standardised description of the method of measurement of the bitrate, for example 'bit/s @MGB2'
OBJECT-TYPE    
  DisplayString  

tsConsistencyTable 1.3.6.1.4.1.2696.3.2.1.5.4.3
This table provides the result of the Transport Stream consistency test for each input.
OBJECT-TYPE    
  SEQUENCE OF  
    TsConsistencyEntry

tsConsistencyEntry 1.3.6.1.4.1.2696.3.2.1.5.4.3.1
Row specification
OBJECT-TYPE    
  TsConsistencyEntry  

tsConsistencyInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.1
Input (Transport Stream) on which the consistency check is made.
OBJECT-TYPE    
  InputNumber  

tsConsistencyTestNumber 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.2
Specifies the consistency check test
OBJECT-TYPE    
  IndexConsistencyTest  

tsConsistencyState 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.3
This gives the overall pass/fail state of the consistency check.
OBJECT-TYPE    
  TestState  

tsConsistencyEnable 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.4
Determines whether this test and associated traps are enabled.
OBJECT-TYPE    
  Enable  

tsConsistencyCounter 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.5
Count of the number of times the consistency check has failed.
OBJECT-TYPE    
  Counter32  

tsConsistencyCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.6
Provides the last time at which there was a discontinuity in the tsConsistencyCounter object.
OBJECT-TYPE    
  DateAndTime  

tsConsistencyCounterReset 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.7
tsConsistencyCounter is reset to zero and tsConsistencyCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsConsistencyLatestError 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.8
The timestamp at the most recent failure of the consistency check.
OBJECT-TYPE    
  DateAndTime  

tsConsistencyActiveTime 1.3.6.1.4.1.2696.3.2.1.5.4.3.1.9
The total time when it has been possible to perform this test
OBJECT-TYPE    
  ActiveTime  

tsMeasurePreferences 1.3.6.1.4.1.2696.3.2.1.5.4.100
OBJECT IDENTIFIER    

tsMeasurePreferencesTable 1.3.6.1.4.1.2696.3.2.1.5.4.100.1
This table contains configuration information for the tsMeasurements branch of the MIB. Configuration related to the whole Transport Stream is found here.
OBJECT-TYPE    
  SEQUENCE OF  
    TsMeasurePreferencesEntry

tsMeasurePreferencesEntry 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1
Row specification
OBJECT-TYPE    
  TsMeasurePreferencesEntry  

tsMeasurePrefInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsMeasurePrefPCRDemarcationFrequency 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.2
This is the demarcation frequency used by the PCR measurement system to distinguish between inaccuracy/jitter and drift.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefPCRFOMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.3
Maximum permitted PCR_FO (frequency offset). An error is indicated if the measured PCR_FO is outside the range [-tsMeasurePrefPCRFOMax .. +tsMeasurePrefPCRFOMax].
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefPCRDRMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.4
Maximum permitted PCR_DR (drift rate). An error is indicated if the measured PCR_DR is outside the range [-tsMeasurePrefPCRDRMax .. +tsMeasurePrefPCRDRMax]
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefPCROJMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.5
Maximum permitted PCR_OJ (overall jitter). An error is indicated if the measured PCR_OJ is outside the range [-tsMeasurePrefPCROJMax .. +tsMeasurePrefPCROJMax]
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefTSBitRateTau 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.6
'tau' value for Transport Stream bit rate measurement. The MIB provides very flexible ways of setting the bit rate measurement parameters tau, N and element for the Transport Stream, services, PIDs and for individual services and PIDs. Real measurement equipment can be expected to provide much less flexibility. Management software should anticipate this by either being statically aware of the capabilities of the agent or by checking that preference settings have been accepted by reading them back after each attempt to set them.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefTSBitRateN 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.7
'N' value for Transport Stream bit rate measurement. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  Unsigned32  

tsMeasurePrefTSBitRateElement 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.8
Data unit which is counted by the bit rate measurement algorithm. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  BitRateElement  

tsMeasurePrefTSBitRateMin 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.9
An error is generated if the Transport Stream bit rate is below this value.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefTSBitRateMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.10
An error is generated if the Transport Stream bit rate exceeds this value.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefAllServiceBitRateTau 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.11
'tau' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefServiceBitRateTau columns in all the rows of the tsMeasurePreferencesServiceTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefAllServiceBitRateN 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.12
'N' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefServiceBitRateN columns in all the rows of the tsMeasurePreferencesServiceTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  Unsigned32  

tsMeasurePrefAllServiceBitRateElement 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.13
Data unit which is counted by the bit rate measurement algorithm for services. When a manager sets the value of this object, the values of the tsMeasurePrefServiceBitRateElement columns in all the rows of the tsMeasurePreferencesServiceTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  BitRateElement  

tsMeasurePrefAllPIDBitRateTau 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.14
'tau' value for Service bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefPIDBitRateTau columns in all the rows of the tsMeasurePreferencesPIDTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefAllPIDBitRateN 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.15
'N' value for PID bit rate measurement. When a manager sets the value of this object, the values of the tsMeasurePrefPIDBitRateN columns in all the rows of the tsMeasurePreferencesPIDTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  Unsigned32  

tsMeasurePrefAllPIDBitRateElement 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.16
Data unit which is counted by the bit rate measurement algorithm for PIDs. When a manager sets the value of this object, the values of the tsMeasurePrefPIDBitRateElement columns in all the rows of the tsMeasurePreferencesPIDTable are set to this same value. This also becomes the default value for any new rows created subsequently. See note in description for tsMeasurePrefTSBitRateTau.
OBJECT-TYPE    
  BitRateElement  

tsMeasurePrefExpectedTSID 1.3.6.1.4.1.2696.3.2.1.5.4.100.1.1.17
This object defines the expected Transport Stream ID that is compared with the actual ID to perform the consistency of information check.
OBJECT-TYPE    
  TransportStreamID  

tsMeasurePreferencesServiceTable 1.3.6.1.4.1.2696.3.2.1.5.4.100.2
This table contains configuration information for the tsMeasurements branch of the MIB. Configuration related to individual services is found here.
OBJECT-TYPE    
  SEQUENCE OF  
    TsMeasurePreferencesServiceEntry

tsMeasurePreferencesServiceEntry 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1
Row specification
OBJECT-TYPE    
  TsMeasurePreferencesServiceEntry  

tsMeasurePrefServiceInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsMeasurePrefServiceService 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.2
Service to which the preferences apply.
OBJECT-TYPE    
  ServiceId  

tsMeasurePrefServiceRowStatus 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.3
This is used by the manager to create and delete rows in the table. The agent will automatically create rows for services it finds in the PMT.
OBJECT-TYPE    
  RowStatus  

tsMeasurePrefServiceBitRateTau 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.4
'tau' value for bit rate measurement for this service. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per service tau settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefServiceBitRateN 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.5
'N' value for rate measurement for this service. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per service 'N' settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  Unsigned32  

tsMeasurePrefServiceBitRateElement 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.6
Data unit which is counted by the bit rate measurement algorithm for this service. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per service element settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  BitRateElement  

tsMeasurePrefServiceBitRateMin 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.7
An error is generated if the Service bit rate is below this value.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefServiceBitRateMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.2.1.8
An error is generated if the Transport Stream bit rate exceeds this value.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePreferencesPIDTable 1.3.6.1.4.1.2696.3.2.1.5.4.100.3
This table contains configuration information for the tsMeasurements branch of the MIB. Configuration related to individual PIDs is found here.
OBJECT-TYPE    
  SEQUENCE OF  
    TsMeasurePreferencesPIDEntry

tsMeasurePreferencesPIDEntry 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1
Row specification
OBJECT-TYPE    
  TsMeasurePreferencesPIDEntry  

tsMeasurePrefPIDInputNumber 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsMeasurePrefPIDPID 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.2
PID (plus one) to which the preferences apply.
OBJECT-TYPE    
  PIDPlusOne  

tsMeasurePrefPIDRowStatus 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.3
This is used by the manager to create and delete rows in the table. The agent will automatically create rows for PIDs which have a non-zero bit rate.
OBJECT-TYPE    
  RowStatus  

tsMeasurePrefPIDBitRateTau 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.4
'tau' value for bit rate measurement for this PID. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per PID tau settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefPIDBitRateN 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.5
'N' value for bit rate measurement for this PID. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per PID 'N' settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  Unsigned32  

tsMeasurePrefPIDBitRateElement 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.6
Data unit which is counted by the bit rate measurement algorithm for this PID. See note in description for tsMeasurePrefTSBitRateTau. If an agent does not support per PID element settings, it shall ignore attempts to change the setting by writing to this object.
OBJECT-TYPE    
  BitRateElement  

tsMeasurePrefPIDBitRateMin 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.7
An error is generated if the PID bit rate is below this value.
OBJECT-TYPE    
  FloatingPoint  

tsMeasurePrefPIDBitRateMax 1.3.6.1.4.1.2696.3.2.1.5.4.100.3.1.8
An error is generated if the PID bit rate exceeds this value.
OBJECT-TYPE    
  FloatingPoint  

tsServicePerformance 1.3.6.1.4.1.2696.3.2.1.5.5
OBJECT IDENTIFIER    

tsServicePerformanceTable 1.3.6.1.4.1.2696.3.2.1.5.5.2
This table gives access to the Service Performance measurements and tests
OBJECT-TYPE    
  SEQUENCE OF  
    TsServicePerformanceEntry

tsServicePerformanceEntry 1.3.6.1.4.1.2696.3.2.1.5.5.2.1
Row specification
OBJECT-TYPE    
  TsServicePerformanceEntry  

tsServicePerformanceInputNumber 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

tsServicePerformanceNumber 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.2
The Service Performance measurement which this row applies to.
OBJECT-TYPE    
  IndexServicePerformance  

tsServicePerformanceState 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.3
This gives the overall pass/fail state of the threshold test on this measurement. The threshold test fails if the value of tsServicePerformanceErrorRatio exceeds the value given in the preferences.
OBJECT-TYPE    
  TestState  

tsServicePerformanceEnable 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.4
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

tsServicePerformanceCounter 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.5
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

tsServicePerformanceCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.6
Provides the last time at which there was a discontinuity in the tsServicePerformanceCounter object.
OBJECT-TYPE    
  DateAndTime  

tsServicePerformanceCounterReset 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.7
tsServicePerformanceCounter is reset to zero and tsServicePerformanceCounterDiscontinuity is set to the current time if 'true' is written to this variable. The value read from this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

tsServicePerformanceLatestError 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.8
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

tsServicePerformanceActiveTime 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.9
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

tsServicePerformanceMeasurementState 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.10
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

tsServicePerformanceError 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.11
The calculated xxx_Error parameter as measured at the end of the most recently completed DeltaT period.
OBJECT-TYPE    
  Unsigned32  

tsServicePerformanceErrorRatio 1.3.6.1.4.1.2696.3.2.1.5.5.2.1.12
This is the calculated xxx_Error_Ratio as a percentage (e.g. '1.32'). The value is for the most recently completed evaluation time (e.g. 10 minutes).
OBJECT-TYPE    
  FloatingPoint  

tsServicePerformancePreferencesTable 1.3.6.1.4.1.2696.3.2.1.5.5.100
Parameters controlling the Service Performance measurements
OBJECT-TYPE    
  SEQUENCE OF  
    TsServicePerformancePreferencesEntry

tsServicePerformancePreferencesEntry 1.3.6.1.4.1.2696.3.2.1.5.5.100.1
Row specification
OBJECT-TYPE    
  TsServicePerformancePreferencesEntry  

tsSPPrefInputNumber 1.3.6.1.4.1.2696.3.2.1.5.5.100.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

tsSPPrefNumber 1.3.6.1.4.1.2696.3.2.1.5.5.100.1.2
The service performance parameter to which these preferences apply.
OBJECT-TYPE    
  IndexServicePerformance  

tsSPPrefDeltaT 1.3.6.1.4.1.2696.3.2.1.5.5.100.1.3
The defined time interval over which errors are counted
OBJECT-TYPE    
  FloatingPoint  

tsSPPrefEvaluationTime 1.3.6.1.4.1.2696.3.2.1.5.5.100.1.4
The period over which the ...Error_Ratio is calculated
OBJECT-TYPE    
  FloatingPoint  

tsSPPrefThreshold 1.3.6.1.4.1.2696.3.2.1.5.5.100.1.5
The threshold value used in calculating the ..._Error_Ratio.
OBJECT-TYPE    
  FloatingPoint  

tr101290CableSat 1.3.6.1.4.1.2696.3.2.1.6
OBJECT IDENTIFIER    

sysAvailabilityTable 1.3.6.1.4.1.2696.3.2.1.6.1
System availability measurement
OBJECT-TYPE    
  SEQUENCE OF  
    SysAvailabilityEntry

sysAvailabilityEntry 1.3.6.1.4.1.2696.3.2.1.6.1.1
Row specification
OBJECT-TYPE    
  SysAvailabilityEntry  

sysAvailabilityInputNumber 1.3.6.1.4.1.2696.3.2.1.6.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

sysAvailabilityTestState 1.3.6.1.4.1.2696.3.2.1.6.1.1.2
A 'fail' is an approximate indication that the system is in a period of unavailable time (UAT). 'fail' is indicated as soon as a trigger period for unavailable time completes. 'pass' is indicated as soon as a trigger period for available time completes. This necessarily differs from the strict definition of UAT because the measuring equipment is unable to look into the future.
OBJECT-TYPE    
  TestState  

sysAvailabilityEnable 1.3.6.1.4.1.2696.3.2.1.6.1.1.3
Determines whether system availability testing is performed and whether the associated traps are generated.
OBJECT-TYPE    
  Enable  

sysAvailabilityCounter 1.3.6.1.4.1.2696.3.2.1.6.1.1.4
Count of the number of times the system has become unavailable
OBJECT-TYPE    
  Counter32  

sysAvailabilityCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.1.1.5
Provides the last time at which there was a discontinuity in the sysAvailabilityCounter object.
OBJECT-TYPE    
  DateAndTime  

sysAvailabilityCounterReset 1.3.6.1.4.1.2696.3.2.1.6.1.1.6
sysAvailabilityCounter is reset to zero and sysAvailabilityCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

sysAvailabilityLatestError 1.3.6.1.4.1.2696.3.2.1.6.1.1.7
The timestamp when the system most recently became unavailable.
OBJECT-TYPE    
  DateAndTime  

sysAvailabilityActiveTime 1.3.6.1.4.1.2696.3.2.1.6.1.1.8
This is a monotonically increasing value in units of seconds that represents the total amount of time for which the instrument has been able to perform the test/measurement. It can be used to calculate the Total Time in the calculation of the availability.
OBJECT-TYPE    
  ActiveTime  

sysAvailabilityMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

sysAvailabilityUnavailableTime 1.3.6.1.4.1.2696.3.2.1.6.1.1.10
This is a monotonically increasing time in seconds which measures the total Unavailable Time (UAT) since the measuring system was last restarted.
OBJECT-TYPE    
  Unsigned32  

sysAvailabilityRatio 1.3.6.1.4.1.2696.3.2.1.6.1.1.11
This is the System Availability ratio as a percentage (e.g. 99.643) measured over the previous 'Total Time' measurement period.
OBJECT-TYPE    
  FloatingPoint  

sysAvailabilityInSETI 1.3.6.1.4.1.2696.3.2.1.6.1.1.12
This object has the value 'true' if and only if the most recently completed Time Interval (TI) was a Severely Errored Time Interval (SETI).
OBJECT-TYPE    
  TruthValue  

linkAvailabilityTable 1.3.6.1.4.1.2696.3.2.1.6.2
Link availability measurement
OBJECT-TYPE    
  SEQUENCE OF  
    LinkAvailabilityEntry

linkAvailabilityEntry 1.3.6.1.4.1.2696.3.2.1.6.2.1
Row specification
OBJECT-TYPE    
  LinkAvailabilityEntry  

linkAvailabilityInputNumber 1.3.6.1.4.1.2696.3.2.1.6.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

linkAvailabilityTestState 1.3.6.1.4.1.2696.3.2.1.6.2.1.2
A 'fail' is an approximate indication that the system is in a period of link unavailable time (LUAT). 'fail' is indicated as soon as a trigger period for link unavailable time completes. 'pass' is indicated as soon as a trigger period for link available time completes. This necessarily differs from the strict definition of LUAT because the measuring equipment is unable to look into the future.
OBJECT-TYPE    
  TestState  

linkAvailabilityEnable 1.3.6.1.4.1.2696.3.2.1.6.2.1.3
Determines whether link availability testing is performed and whether the associated traps are generated.
OBJECT-TYPE    
  Enable  

linkAvailabilityCounter 1.3.6.1.4.1.2696.3.2.1.6.2.1.4
Count of the number of times the link has become unavailable.
OBJECT-TYPE    
  Counter32  

linkAvailabilityCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.2.1.5
Provides the last time at which there was a discontinuity in the linkAvailabilityCounter object.
OBJECT-TYPE    
  DateAndTime  

linkAvailabilityCounterReset 1.3.6.1.4.1.2696.3.2.1.6.2.1.6
linkAvailabilityCounter is reset to zero and linkAvailabilityCounterDiscontinuity is set to the current time if 'true' is written to this variable. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

linkAvailabilityLatestError 1.3.6.1.4.1.2696.3.2.1.6.2.1.7
The timestamp when the link most recently became unavailable.
OBJECT-TYPE    
  DateAndTime  

linkAvailabilityActiveTime 1.3.6.1.4.1.2696.3.2.1.6.2.1.8
This is a monotonically increasing value in units of seconds that represents the total amount of time for which the instrument has been able to perform the measurement. It can be used to calculate the Total Time in the calculation of the availability.
OBJECT-TYPE    
  ActiveTime  

linkAvailabilityMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.2.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

linkAvailabilityUnavailableTime 1.3.6.1.4.1.2696.3.2.1.6.2.1.10
This is a monotonically increasing time in seconds which measures the total link unavailable time (LUAT) since the measuring system was last restarted.
OBJECT-TYPE    
  Unsigned32  

linkAvailabilityRatio 1.3.6.1.4.1.2696.3.2.1.6.2.1.11
This is the Link Availability ratio as a percentage (e.g. 99.643) measured over the previous 'Total Time' measurement period.
OBJECT-TYPE    
  FloatingPoint  

linkAvailabilityInSUTI 1.3.6.1.4.1.2696.3.2.1.6.2.1.12
This object has the value 'true' if and only if the most recently completed Time Interval (TI) was a Severely Uncorrectable Time Interval (SETI).
OBJECT-TYPE    
  TruthValue  

berRSinServiceTable 1.3.6.1.4.1.2696.3.2.1.6.3
Measurement of BER before RS decoder
OBJECT-TYPE    
  SEQUENCE OF  
    BerRSinServiceEntry

berRSinServiceEntry 1.3.6.1.4.1.2696.3.2.1.6.3.1
Row specification
OBJECT-TYPE    
  BerRSinServiceEntry  

berRSinServiceInputNumber 1.3.6.1.4.1.2696.3.2.1.6.3.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berRSinServiceTestState 1.3.6.1.4.1.2696.3.2.1.6.3.1.2
This indicates whether the berRSinServiceValue is below the maximum.
OBJECT-TYPE    
  TestState  

berRSinServiceEnable 1.3.6.1.4.1.2696.3.2.1.6.3.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berRSinServiceCounter 1.3.6.1.4.1.2696.3.2.1.6.3.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berRSinServiceCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.3.1.5
Provides the last time at which there was a discontinuity in the berRSinServiceCounter object.
OBJECT-TYPE    
  DateAndTime  

berRSinServiceCounterReset 1.3.6.1.4.1.2696.3.2.1.6.3.1.6
berRSinServiceCounter is reset to zero and berRSinServiceCounterDiscontinuity is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berRSinServiceLatestError 1.3.6.1.4.1.2696.3.2.1.6.3.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berRSinServiceActiveTime 1.3.6.1.4.1.2696.3.2.1.6.3.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berRSinServiceMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.3.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

berRSinServiceValue 1.3.6.1.4.1.2696.3.2.1.6.3.1.10
This is the current BER as a numeric value, for example 0.0000023
OBJECT-TYPE    
  FloatingPoint  

rfIFsignalPowerTable 1.3.6.1.4.1.2696.3.2.1.6.6
RF or IF signal power measurement
OBJECT-TYPE    
  SEQUENCE OF  
    RfIFsignalPowerEntry

rfIFsignalPowerEntry 1.3.6.1.4.1.2696.3.2.1.6.6.1
Row specification
OBJECT-TYPE    
  RfIFsignalPowerEntry  

rfIFsignalPowerInputNumber 1.3.6.1.4.1.2696.3.2.1.6.6.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rfIFsignalPowerTestState 1.3.6.1.4.1.2696.3.2.1.6.6.1.2
This indicates whether the rfIFsignalPowerValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

rfIFsignalPowerEnable 1.3.6.1.4.1.2696.3.2.1.6.6.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

rfIFsignalPowerCounter 1.3.6.1.4.1.2696.3.2.1.6.6.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

rfIFsignalPowerCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.6.1.5
Provides the last time at which there was a discontinuity in the rfIFsignalPowerCounter object.
OBJECT-TYPE    
  DateAndTime  

rfIFsignalPowerCounterReset 1.3.6.1.4.1.2696.3.2.1.6.6.1.6
rfIFsignalPowerCounter is reset to zero and rfIFsignalPowerCounterDiscontinuity is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rfIFsignalPowerLatestError 1.3.6.1.4.1.2696.3.2.1.6.6.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

rfIFsignalPowerActiveTime 1.3.6.1.4.1.2696.3.2.1.6.6.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

rfIFsignalPowerMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.6.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

rfIFsignalPowerValue 1.3.6.1.4.1.2696.3.2.1.6.6.1.10
The current RF power expressed in dBm, which references 0 dBm as the power of 1 mW.
OBJECT-TYPE    
  FloatingPoint  

noisePowerTable 1.3.6.1.4.1.2696.3.2.1.6.7
Noise power measurement
OBJECT-TYPE    
  SEQUENCE OF  
    NoisePowerEntry

noisePowerEntry 1.3.6.1.4.1.2696.3.2.1.6.7.1
Row specification
OBJECT-TYPE    
  NoisePowerEntry  

noisePowerInputNumber 1.3.6.1.4.1.2696.3.2.1.6.7.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

noisePowerTestState 1.3.6.1.4.1.2696.3.2.1.6.7.1.2
This indicates whether the noisePowerValue is currently below the maximum limit.
OBJECT-TYPE    
  TestState  

noisePowerEnable 1.3.6.1.4.1.2696.3.2.1.6.7.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

noisePowerCounter 1.3.6.1.4.1.2696.3.2.1.6.7.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

noisePowerCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.7.1.5
Provides the last time at which there was a discontinuity in the noisePowerCounter object.
OBJECT-TYPE    
  DateAndTime  

noisePowerCounterReset 1.3.6.1.4.1.2696.3.2.1.6.7.1.6
noisePowerCounter is reset to zero and noisePowerCounterDiscontinuity is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

noisePowerLatestError 1.3.6.1.4.1.2696.3.2.1.6.7.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

noisePowerActiveTime 1.3.6.1.4.1.2696.3.2.1.6.7.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

noisePowerMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.7.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

noisePowerValue 1.3.6.1.4.1.2696.3.2.1.6.7.1.10
The current RF noise power expressed in dBm, which references 0 dBm as the power of 1 mW.
OBJECT-TYPE    
  FloatingPoint  

iqAnalysisCS 1.3.6.1.4.1.2696.3.2.1.6.9
OBJECT IDENTIFIER    

merCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.2
Modulation Error Ratio (MER)
OBJECT-TYPE    
  SEQUENCE OF  
    MerCSEntry

merCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.2.1
Row specification
OBJECT-TYPE    
  MerCSEntry  

merCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

merCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.2
This indicates whether the merCSValue is currently below the maximum limit.
OBJECT-TYPE    
  TestState  

merCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

merCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

merCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.5
Provides the last time at which there was a discontinuity in the merCSCounter object.
OBJECT-TYPE    
  DateAndTime  

merCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.6
merCSCounter is reset to zero and merCSCounterDiscontinuity is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

merCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

merCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

merCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

merCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.2.1.10
The Modulation Error Ratio expressed in dB
OBJECT-TYPE    
  FloatingPoint  

steCS 1.3.6.1.4.1.2696.3.2.1.6.9.3
OBJECT IDENTIFIER    

steMeanCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.3.1
System Target Error (mean value)
OBJECT-TYPE    
  SEQUENCE OF  
    SteMeanCSEntry

steMeanCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1
Row specification
OBJECT-TYPE    
  SteMeanCSEntry  

steMeanCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

steMeanCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.2
This indicates whether the steMeanCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

steMeanCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

steMeanCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

steMeanCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

steMeanCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

steMeanCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

steMeanCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

steMeanCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

steMeanCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.3.1.1.10
The current System Target Error Mean as a numeric value
OBJECT-TYPE    
  FloatingPoint  

steDeviationCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.3.2
System Target Error (deviation value)
OBJECT-TYPE    
  SEQUENCE OF  
    SteDeviationCSEntry

steDeviationCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1
Row specification
OBJECT-TYPE    
  SteDeviationCSEntry  

steDeviationCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

steDeviationCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.2
This indicates whether the steDeviationCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

steDeviationCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

steDeviationCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

steDeviationCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

steDeviationCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

steDeviationCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

steDeviationCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

steDeviationCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

steDeviationCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.3.2.1.10
The current System Target Error Deviation as a numeric value
OBJECT-TYPE    
  FloatingPoint  

csCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.4
Carrier suppression measurement
OBJECT-TYPE    
  SEQUENCE OF  
    CsCSEntry

csCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.4.1
Row specification
OBJECT-TYPE    
  CsCSEntry  

csCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

csCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.2
This indicates whether the csCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

csCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

csCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

csCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

csCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

csCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

csCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

csCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

csCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.4.1.10
The current Carrier Suppression value in dB.
OBJECT-TYPE    
  FloatingPoint  

aiCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.5
Amplitude Imbalance (AI) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    AiCSEntry

aiCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.5.1
Row specification
OBJECT-TYPE    
  AiCSEntry  

aiCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

aiCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.2
This indicates whether the aiCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

aiCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

aiCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

aiCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

aiCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

aiCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

aiCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

aiCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

aiCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.5.1.10
The current Amplitude Imbalance as a percentage
OBJECT-TYPE    
  FloatingPoint  

qeCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.6
Quadrature Error (QE) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    QeCSEntry

qeCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.6.1
Row specification
OBJECT-TYPE    
  QeCSEntry  

qeCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

qeCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.2
This indicates whether the qeCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

qeCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

qeCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

qeCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

qeCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

qeCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

qeCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

qeCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

qeCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.6.1.10
The current Quadrature Error value in degrees.
OBJECT-TYPE    
  FloatingPoint  

rteCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.7
Residual Target Error (RTE) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    RteCSEntry

rteCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.7.1
Row description
OBJECT-TYPE    
  RteCSEntry  

rteCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rteCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.2
This indicates whether the rteCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

rteCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

rteCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

rteCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

rteCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rteCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

rteCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

rteCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

rteCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.7.1.10
The current Residual Target Error value as a numeric value.
OBJECT-TYPE    
  FloatingPoint  

ciCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.8
Coherent Interferer measurement
OBJECT-TYPE    
  SEQUENCE OF  
    CiCSEntry

ciCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.8.1
Row specification
OBJECT-TYPE    
  CiCSEntry  

ciCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

ciCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.2
This indicates whether the ciCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

ciCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

ciCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

ciCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

ciCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

ciCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

ciCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

ciCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

ciCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.8.1.10
The current Coherent Interferer value in dB.
OBJECT-TYPE    
  FloatingPoint  

pjCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.9
Phase Jitter (PJ) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    PjCSEntry

pjCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.9.1
Row specification
OBJECT-TYPE    
  PjCSEntry  

pjCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

pjCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.2
This indicates whether the pjCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

pjCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

pjCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

pjCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

pjCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

pjCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

pjCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

pjCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

pjCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.9.1.10
The current Phase Jitter value in degrees.
OBJECT-TYPE    
  FloatingPoint  

snrCSTable 1.3.6.1.4.1.2696.3.2.1.6.9.10
Signal-to-Noise Ratio (SNR)
OBJECT-TYPE    
  SEQUENCE OF  
    SnrCSEntry

snrCSEntry 1.3.6.1.4.1.2696.3.2.1.6.9.10.1
Row specification
OBJECT-TYPE    
  SnrCSEntry  

snrCSInputNumber 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

snrCSTestState 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.2
This indicates whether the snrCSValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

snrCSEnable 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

snrCSCounter 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

snrCSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

snrCSCounterReset 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

snrCSLatestError 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

snrCSActiveTime 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

snrCSMeasurementState 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

snrCSValue 1.3.6.1.4.1.2696.3.2.1.6.9.10.1.10
The current Signal-to-Noise value in dB.
OBJECT-TYPE    
  FloatingPoint  

cableSatPreferencesTable 1.3.6.1.4.1.2696.3.2.1.6.100
Table containing per input configuration information for cable and satellite common measurements.
OBJECT-TYPE    
  SEQUENCE OF  
    CableSatPreferencesEntry

cableSatPreferencesEntry 1.3.6.1.4.1.2696.3.2.1.6.100.1
Row specification
OBJECT-TYPE    
  CableSatPreferencesEntry  

cableSatPrefInputNumber 1.3.6.1.4.1.2696.3.2.1.6.100.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

cableSatPrefCentreFrequency 1.3.6.1.4.1.2696.3.2.1.6.100.1.2
This is the centre frequency to which the measuring equipment is tuned for making cable and satellite measurements. This frequency is the actual input frequency to the measuring equipment, which may be at an intermediate frequency (IF) rather than the final RF. This setting affects the objects in the 'tr101290Cable' and 'tr101290Satellite' branches of the MIB as well as the 'tr101290CableSat' branch.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefModulation 1.3.6.1.4.1.2696.3.2.1.6.100.1.3
This is the modulation which the measuring equipment expects to see and against which it makes modulation measurements. This applies to cable and satellite measurements. This setting affects the objects in the 'tr101290Cable' and 'tr101290Satellite' branches of the MIB as well as the 'tr101290CableSat' branch.
OBJECT-TYPE    
  Modulation  

cableSatPrefSysAvailUATMode 1.3.6.1.4.1.2696.3.2.1.6.100.1.4
Determines whether the 'N consecutive' or 'rolling window' mode of determining the start of a period of Unavailable Time (UAT) is used. If the 'N consecutive' mode is selected, the 'M' and 'T' preference parameters are ignored. Likewise, if the 'rolling window' mode is selected, the 'N' preference parameter is ignored.
OBJECT-TYPE    
  UATMode  

cableSatPrefSysAvailN 1.3.6.1.4.1.2696.3.2.1.6.100.1.5
The N value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  Unsigned32  

cableSatPrefSysAvailT 1.3.6.1.4.1.2696.3.2.1.6.100.1.6
The T value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSysAvailM 1.3.6.1.4.1.2696.3.2.1.6.100.1.7
The M value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  Unsigned32  

cableSatPrefSysAvailTI 1.3.6.1.4.1.2696.3.2.1.6.100.1.8
Each Time Interval of this length is assessed as to whether it is a Severely Errored Time Interval.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSysAvailEBPerCent 1.3.6.1.4.1.2696.3.2.1.6.100.1.9
If more than this percentage of blocks within a Time Interval is an Errored Block, the Time Interval is a Severely Errored Time Interval (SETI). Example values are: '1.53', '10', '0.33'.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSysAvailTotalTime 1.3.6.1.4.1.2696.3.2.1.6.100.1.10
The Total Time over which the System Availability is calculated.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefLinkAvailUATMode 1.3.6.1.4.1.2696.3.2.1.6.100.1.11
Determines whether the 'N consecutive' or 'rolling window' mode of determining the start of a period of Link Unavailable Time (LUAT) is used. If the 'N consecutive' mode is selected, the 'M' and 'T' preference parameters are ignored. Likewise, if the 'rolling window' mode is selected, the 'N' preference parameter is ignored.
OBJECT-TYPE    
  UATMode  

cableSatPrefLinkAvailN 1.3.6.1.4.1.2696.3.2.1.6.100.1.12
The N value used to identify the start and end of a period of Link Unavailable Time (LUAT).
OBJECT-TYPE    
  Unsigned32  

cableSatPrefLinkAvailT 1.3.6.1.4.1.2696.3.2.1.6.100.1.13
The T value used to identify the start and end of a period of Link Unavailable Time (LUAT).
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefLinkAvailM 1.3.6.1.4.1.2696.3.2.1.6.100.1.14
The M value used to identify the start and end of a period of Link Unavailable Time (LUAT).
OBJECT-TYPE    
  Unsigned32  

cableSatPrefLinkAvailTI 1.3.6.1.4.1.2696.3.2.1.6.100.1.15
Each Time Interval of this length is assessed as to whether it is a Severely Uncorrectable Time Interval (SUTI).
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefLinkAvailUPPerCent 1.3.6.1.4.1.2696.3.2.1.6.100.1.16
If more than this percentage of packets within a Time Interval is an Uncorrectable Packet (UP), the Time Interval is a Severely Uncorrectable Time Interval (SUTI). Example values are: '1.53', '10', '0.33'.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefLinkAvailTotalTime 1.3.6.1.4.1.2696.3.2.1.6.100.1.17
The Total Time over which the Link Availability is calculated.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefBERMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.18
If the berRSinServiceValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSignalPowerMin 1.3.6.1.4.1.2696.3.2.1.6.100.1.19
If the power measured by rfIFsignalPowerValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSignalPowerMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.20
If the power measured by rfIFsignalPowerValue is greater than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefNoisePowerMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.21
If the noise power measured by noisePowerValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefMerCSMin 1.3.6.1.4.1.2696.3.2.1.6.100.1.22
If the merCSValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSteMeanCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.23
If the steMeanCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSteDeviationCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.24
If the steDeviationCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefCsCSMin 1.3.6.1.4.1.2696.3.2.1.6.100.1.25
If the csCSValue is less than this value, the associated test fails
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefAiCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.26
If aiCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefQeCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.27
If qeCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefRteCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.28
If rteCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefCiCSMin 1.3.6.1.4.1.2696.3.2.1.6.100.1.29
If ciCSValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefPjCSMax 1.3.6.1.4.1.2696.3.2.1.6.100.1.30
If pjCSValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cableSatPrefSnrCSMin 1.3.6.1.4.1.2696.3.2.1.6.100.1.31
If snrCSValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

tr101290Cable 1.3.6.1.4.1.2696.3.2.1.7
OBJECT IDENTIFIER    

noiseMarginTable 1.3.6.1.4.1.2696.3.2.1.7.1
Noise margin measurement
OBJECT-TYPE    
  SEQUENCE OF  
    NoiseMarginEntry

noiseMarginEntry 1.3.6.1.4.1.2696.3.2.1.7.1.1
Row description
OBJECT-TYPE    
  NoiseMarginEntry  

noiseMarginInputNumber 1.3.6.1.4.1.2696.3.2.1.7.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

noiseMarginTestState 1.3.6.1.4.1.2696.3.2.1.7.1.1.2
This indicates whether the noiseMarginValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

noiseMarginEnable 1.3.6.1.4.1.2696.3.2.1.7.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

noiseMarginCounter 1.3.6.1.4.1.2696.3.2.1.7.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

noiseMarginCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.7.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

noiseMarginCounterReset 1.3.6.1.4.1.2696.3.2.1.7.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

noiseMarginLatestError 1.3.6.1.4.1.2696.3.2.1.7.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

noiseMarginActiveTime 1.3.6.1.4.1.2696.3.2.1.7.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

noiseMarginMeasurementState 1.3.6.1.4.1.2696.3.2.1.7.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

noiseMarginValue 1.3.6.1.4.1.2696.3.2.1.7.1.1.10
The current Noise Margin value in dB.
OBJECT-TYPE    
  FloatingPoint  

estNoiseMarginTable 1.3.6.1.4.1.2696.3.2.1.7.2
Estimated noise margin measurement
OBJECT-TYPE    
  SEQUENCE OF  
    EstNoiseMarginEntry

estNoiseMarginEntry 1.3.6.1.4.1.2696.3.2.1.7.2.1
Row description
OBJECT-TYPE    
  EstNoiseMarginEntry  

estNoiseMarginInputNumber 1.3.6.1.4.1.2696.3.2.1.7.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

estNoiseMarginTestState 1.3.6.1.4.1.2696.3.2.1.7.2.1.2
This indicates whether the estNoiseMarginValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

estNoiseMarginEnable 1.3.6.1.4.1.2696.3.2.1.7.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

estNoiseMarginCounter 1.3.6.1.4.1.2696.3.2.1.7.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

estNoiseMarginCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.7.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

estNoiseMarginCounterReset 1.3.6.1.4.1.2696.3.2.1.7.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

estNoiseMarginLatestError 1.3.6.1.4.1.2696.3.2.1.7.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

estNoiseMarginActiveTime 1.3.6.1.4.1.2696.3.2.1.7.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

estNoiseMarginMeasurementState 1.3.6.1.4.1.2696.3.2.1.7.2.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

estNoiseMarginValue 1.3.6.1.4.1.2696.3.2.1.7.2.1.10
The current Estimated Noise Margin value in dB.
OBJECT-TYPE    
  FloatingPoint  

signQualMarTTable 1.3.6.1.4.1.2696.3.2.1.7.3
Signal quality margin test
OBJECT-TYPE    
  SEQUENCE OF  
    SignQualMarTEntry

signQualMarTEntry 1.3.6.1.4.1.2696.3.2.1.7.3.1
Row description
OBJECT-TYPE    
  SignQualMarTEntry  

signQualMarTInputNumber 1.3.6.1.4.1.2696.3.2.1.7.3.1.1
Transport Stream on which the test is done
OBJECT-TYPE    
  InputNumber  

signQualMarTTestState 1.3.6.1.4.1.2696.3.2.1.7.3.1.2
This indicates an error if the percentage of IQ points outside the threshold box exceeds cablePrefSignQualPercentMax.
OBJECT-TYPE    
  TestState  

signQualMarTEnable 1.3.6.1.4.1.2696.3.2.1.7.3.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

signQualMarTCounter 1.3.6.1.4.1.2696.3.2.1.7.3.1.4
Count of the number of times an error has occurred.
OBJECT-TYPE    
  Counter32  

signQualMarTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.7.3.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

signQualMarTCounterReset 1.3.6.1.4.1.2696.3.2.1.7.3.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

signQualMarTLatestError 1.3.6.1.4.1.2696.3.2.1.7.3.1.7
The timestamp at the most recent occurrence of an error.
OBJECT-TYPE    
  DateAndTime  

signQualMarTActiveTime 1.3.6.1.4.1.2696.3.2.1.7.3.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNDCTable 1.3.6.1.4.1.2696.3.2.1.7.4
Equivalent Noise Degradation (END) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    ENDCEntry

eNDCEntry 1.3.6.1.4.1.2696.3.2.1.7.4.1
Row description
OBJECT-TYPE    
  ENDCEntry  

eNDCInputNumber 1.3.6.1.4.1.2696.3.2.1.7.4.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

eNDCTestState 1.3.6.1.4.1.2696.3.2.1.7.4.1.2
This indicates an error when the eNDCValue exceeds the threshold.
OBJECT-TYPE    
  TestState  

eNDCEnable 1.3.6.1.4.1.2696.3.2.1.7.4.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

eNDCCounter 1.3.6.1.4.1.2696.3.2.1.7.4.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

eNDCCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.7.4.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

eNDCCounterReset 1.3.6.1.4.1.2696.3.2.1.7.4.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

eNDCLatestError 1.3.6.1.4.1.2696.3.2.1.7.4.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

eNDCActiveTime 1.3.6.1.4.1.2696.3.2.1.7.4.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNDCMeasurementState 1.3.6.1.4.1.2696.3.2.1.7.4.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

eNDCValue 1.3.6.1.4.1.2696.3.2.1.7.4.1.10
The current Equivalent Noise Degradation value in dB.
OBJECT-TYPE    
  FloatingPoint  

outBandEmissTable 1.3.6.1.4.1.2696.3.2.1.7.5
Out of band emissions test
OBJECT-TYPE    
  SEQUENCE OF  
    OutBandEmissEntry

outBandEmissEntry 1.3.6.1.4.1.2696.3.2.1.7.5.1
Row specification
OBJECT-TYPE    
  OutBandEmissEntry  

outBandEmissInputNumber 1.3.6.1.4.1.2696.3.2.1.7.5.1.1
Transport Stream on which the test is made
OBJECT-TYPE    
  InputNumber  

outBandEmissTestState 1.3.6.1.4.1.2696.3.2.1.7.5.1.2
This indicates whether the spectrum is within the spectrum mask. Note that the spectrum mask must be provided to the instrument by means outside the scope of this MIB.
OBJECT-TYPE    
  TestState  

outBandEmissEnable 1.3.6.1.4.1.2696.3.2.1.7.5.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

outBandEmissCounter 1.3.6.1.4.1.2696.3.2.1.7.5.1.4
Count of the number of times an error has occurred for this test.
OBJECT-TYPE    
  Counter32  

outBandEmissCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.7.5.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

outBandEmissCounterReset 1.3.6.1.4.1.2696.3.2.1.7.5.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

outBandEmissLatestError 1.3.6.1.4.1.2696.3.2.1.7.5.1.7
The timestamp at the most recent occurrence of an error on this test.
OBJECT-TYPE    
  DateAndTime  

outBandEmissActiveTime 1.3.6.1.4.1.2696.3.2.1.7.5.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

cablePreferencesTable 1.3.6.1.4.1.2696.3.2.1.7.100
Table containing per input preferences for cable measurements.
OBJECT-TYPE    
  SEQUENCE OF  
    CablePreferencesEntry

cablePreferencesEntry 1.3.6.1.4.1.2696.3.2.1.7.100.1
Row specification
OBJECT-TYPE    
  CablePreferencesEntry  

cablePrefInputNumber 1.3.6.1.4.1.2696.3.2.1.7.100.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

cablePrefNoiseMarginMin 1.3.6.1.4.1.2696.3.2.1.7.100.1.2
If the measured noiseMarginValue is less than this value the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cablePrefEstNoiseMarginMin 1.3.6.1.4.1.2696.3.2.1.7.100.1.3
If the measured estNoiseMarginValue is less than this value the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

cablePrefSignQualBoxSize 1.3.6.1.4.1.2696.3.2.1.7.100.1.4
This object determines the size of the quality threshold box for the signal quality margin test. The quality threshold box is assumed to be square. The value is the ratio of the length of one side of a threshold box to the length of one side of the IQ decision boundary box. An example value is '0.5'.
OBJECT-TYPE    
  FloatingPoint  

cablePrefSignQualPercentMax 1.3.6.1.4.1.2696.3.2.1.7.100.1.5
This object sets the limit on how many constellation points may fall outside the threshold box before the signal quality margin test fails. The value is expressed as a percentage, for example '7.5'.
OBJECT-TYPE    
  Integer32  

cablePrefENDBER 1.3.6.1.4.1.2696.3.2.1.7.100.1.6
BER value which is to be used for the END measurement.
OBJECT-TYPE    
  FloatingPoint  

cablePrefENDCtoNSpecified 1.3.6.1.4.1.2696.3.2.1.7.100.1.7
This determines whether cablePrefENDIdeal is expressed as a C/N ratio (value is true) or an Eb/No ratio (value is false).
OBJECT-TYPE    
  TruthValue  

cablePrefENDIdeal 1.3.6.1.4.1.2696.3.2.1.7.100.1.8
This is the 'ideal' value of C/N or Eb/No for the given BER.
OBJECT-TYPE    
  FloatingPoint  

cablePrefENDMax 1.3.6.1.4.1.2696.3.2.1.7.100.1.9
If the measured END exceeds this value the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

tr101290Satellite 1.3.6.1.4.1.2696.3.2.1.8
OBJECT IDENTIFIER    

berViterbiSTable 1.3.6.1.4.1.2696.3.2.1.8.1
BER before Viterbi decoding measurement
OBJECT-TYPE    
  SEQUENCE OF  
    BerViterbiSEntry

berViterbiSEntry 1.3.6.1.4.1.2696.3.2.1.8.1.1
Row description
OBJECT-TYPE    
  BerViterbiSEntry  

berViterbiSInputNumber 1.3.6.1.4.1.2696.3.2.1.8.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berViterbiSTestState 1.3.6.1.4.1.2696.3.2.1.8.1.1.2
This test fails if either berViterbiSIValue or berViterbiSQValue exceeds the threshold set by satellitePrefBERMax.
OBJECT-TYPE    
  TestState  

berViterbiSEnable 1.3.6.1.4.1.2696.3.2.1.8.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berViterbiSCounter 1.3.6.1.4.1.2696.3.2.1.8.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berViterbiSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.8.1.1.5
Provides the last time at which there was a discontinuity in the berViterbiSCounter object.
OBJECT-TYPE    
  DateAndTime  

berViterbiSCounterReset 1.3.6.1.4.1.2696.3.2.1.8.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berViterbiSLatestError 1.3.6.1.4.1.2696.3.2.1.8.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berViterbiSActiveTime 1.3.6.1.4.1.2696.3.2.1.8.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berViterbiSMeasurementState 1.3.6.1.4.1.2696.3.2.1.8.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

berViterbiSIValue 1.3.6.1.4.1.2696.3.2.1.8.1.1.10
This is the pre-Viterbi I path BER value, for example 0.0000023
OBJECT-TYPE    
  FloatingPoint  

berViterbiSQValue 1.3.6.1.4.1.2696.3.2.1.8.1.1.11
This is the pre-Viterbi Q path BER value, for example 0.0000023
OBJECT-TYPE    
  FloatingPoint  

berViterbiSMeasurementMethod 1.3.6.1.4.1.2696.3.2.1.8.1.1.12
This indicates whether the measurement was made separately for the I and Q parts of the signal or by a measurement of I and Q combined.
OBJECT-TYPE    
  BERMeasurementMethod  

ifSpectrumTable 1.3.6.1.4.1.2696.3.2.1.8.2
IF spectrum test
OBJECT-TYPE    
  SEQUENCE OF  
    IfSpectrumEntry

ifSpectrumEntry 1.3.6.1.4.1.2696.3.2.1.8.2.1
Row specification
OBJECT-TYPE    
  IfSpectrumEntry  

ifSpectrumInputNumber 1.3.6.1.4.1.2696.3.2.1.8.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

ifSpectrumTestState 1.3.6.1.4.1.2696.3.2.1.8.2.1.2
This indicates whether the spectrum conforms to the template. Note that the spectrum mask must be provided to the instrument by means outside the scope of this MIB. The group delay is not tested.
OBJECT-TYPE    
  TestState  

ifSpectrumEnable 1.3.6.1.4.1.2696.3.2.1.8.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

ifSpectrumCounter 1.3.6.1.4.1.2696.3.2.1.8.2.1.4
Count of the number of times an error has occurred for this test.
OBJECT-TYPE    
  Counter32  

ifSpectrumCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.8.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

ifSpectrumCounterReset 1.3.6.1.4.1.2696.3.2.1.8.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

ifSpectrumLatestError 1.3.6.1.4.1.2696.3.2.1.8.2.1.7
The timestamp at the most recent occurrence of an error on this test.
OBJECT-TYPE    
  DateAndTime  

ifSpectrumActiveTime 1.3.6.1.4.1.2696.3.2.1.8.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

satellitePreferencesTable 1.3.6.1.4.1.2696.3.2.1.8.100
Table of satellite specific measurement preferences.
OBJECT-TYPE    
  SEQUENCE OF  
    SatellitePreferencesEntry

satellitePreferencesEntry 1.3.6.1.4.1.2696.3.2.1.8.100.1
Row specification
OBJECT-TYPE    
  SatellitePreferencesEntry  

satellitePrefInputNumber 1.3.6.1.4.1.2696.3.2.1.8.100.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

satellitePrefBERMax 1.3.6.1.4.1.2696.3.2.1.8.100.1.2
This defines the upper limit on the BER before Viterbi measurement
OBJECT-TYPE    
  FloatingPoint  

tr101290Terrestrial 1.3.6.1.4.1.2696.3.2.1.9
OBJECT IDENTIFIER    

rfTerr 1.3.6.1.4.1.2696.3.2.1.9.1
OBJECT IDENTIFIER    

rfAccuracyTable 1.3.6.1.4.1.2696.3.2.1.9.1.1
RF frequency accuracy (Precision)
OBJECT-TYPE    
  SEQUENCE OF  
    RfAccuracyEntry

rfAccuracyEntry 1.3.6.1.4.1.2696.3.2.1.9.1.1.1
Row specification
OBJECT-TYPE    
  RfAccuracyEntry  

rfAccuracyInputNumber 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.1
RF input on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rfAccuracyTestState 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.2
This indicates whether the rfAccuracyValue is within the thresholds.
OBJECT-TYPE    
  TestState  

rfAccuracyEnable 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

rfAccuracyCounter 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

rfAccuracyCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

rfAccuracyCounterReset 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rfAccuracyLatestError 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

rfAccuracyActiveTime 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

rfAccuracyMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.9
Indicates the validity of the measurement
OBJECT-TYPE    
  MeasurementState  

rfAccuracyValue 1.3.6.1.4.1.2696.3.2.1.9.1.1.1.10
This is the RF carrier frequency in Hz.
OBJECT-TYPE    
  FloatingPoint  

rfChannelWidthTable 1.3.6.1.4.1.2696.3.2.1.9.1.2
RF channel width (Sampling Frequency Accuracy)
OBJECT-TYPE    
  SEQUENCE OF  
    RfChannelWidthEntry

rfChannelWidthEntry 1.3.6.1.4.1.2696.3.2.1.9.1.2.1
Row specification
OBJECT-TYPE    
  RfChannelWidthEntry  

rfChannelWidthInputNumber 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rfChannelWidthTestState 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.2
This indicates whether the rfChannelWidthValue is within the thresholds.
OBJECT-TYPE    
  TestState  

rfChannelWidthEnable 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

rfChannelWidthCounter 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

rfChannelWidthCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

rfChannelWidthCounterReset 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rfChannelWidthLatestError 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

rfChannelWidthActiveTime 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

rfChannelWidthMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

rfChannelWidthValue 1.3.6.1.4.1.2696.3.2.1.9.1.2.1.10
This is the RF channel width in Hz.
OBJECT-TYPE    
  FloatingPoint  

symbolLengthTable 1.3.6.1.4.1.2696.3.2.1.9.1.3
Symbol Length measurement at RF (Guard Interval verification)
OBJECT-TYPE    
  SEQUENCE OF  
    SymbolLengthEntry

symbolLengthEntry 1.3.6.1.4.1.2696.3.2.1.9.1.3.1
Row specification
OBJECT-TYPE    
  SymbolLengthEntry  

symbolLengthInputNumber 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

symbolLengthTestState 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.2
This indicates whether the symbolLengthValue is within the thresholds.
OBJECT-TYPE    
  TestState  

symbolLengthEnable 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

symbolLengthCounter 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

symbolLengthCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

symbolLengthCounterReset 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

symbolLengthLatestError 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

symbolLengthActiveTime 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

symbolLengthMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

symbolLengthValue 1.3.6.1.4.1.2696.3.2.1.9.1.3.1.10
This is the symbol length in microseconds.
OBJECT-TYPE    
  FloatingPoint  

rfIfPowerTable 1.3.6.1.4.1.2696.3.2.1.9.5
RF/IF signal power
OBJECT-TYPE    
  SEQUENCE OF  
    RfIfPowerEntry

rfIfPowerEntry 1.3.6.1.4.1.2696.3.2.1.9.5.1
Row specification
OBJECT-TYPE    
  RfIfPowerEntry  

rfIfPowerInputNumber 1.3.6.1.4.1.2696.3.2.1.9.5.1.1
RF input on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rfIfPowerTestState 1.3.6.1.4.1.2696.3.2.1.9.5.1.2
This indicates whether the rfIfPowerValue is within the thresholds.
OBJECT-TYPE    
  TestState  

rfIfPowerEnable 1.3.6.1.4.1.2696.3.2.1.9.5.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

rfIfPowerCounter 1.3.6.1.4.1.2696.3.2.1.9.5.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

rfIfPowerCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.5.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

rfIfPowerCounterReset 1.3.6.1.4.1.2696.3.2.1.9.5.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rfIfPowerLatestError 1.3.6.1.4.1.2696.3.2.1.9.5.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

rfIfPowerActiveTime 1.3.6.1.4.1.2696.3.2.1.9.5.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

rfIfPowerMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.5.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

rfIfPowerValue 1.3.6.1.4.1.2696.3.2.1.9.5.1.10
The current RF power expressed in dBm, which references 0 dBm as the power of 1 mW.
OBJECT-TYPE    
  FloatingPoint  

rfIfSpectrumTable 1.3.6.1.4.1.2696.3.2.1.9.7
RF and IF spectrum mask test
OBJECT-TYPE    
  SEQUENCE OF  
    RfIfSpectrumEntry

rfIfSpectrumEntry 1.3.6.1.4.1.2696.3.2.1.9.7.1
Row specification
OBJECT-TYPE    
  RfIfSpectrumEntry  

rfIfSpectrumInputNumber 1.3.6.1.4.1.2696.3.2.1.9.7.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

rfIfSpectrumTestState 1.3.6.1.4.1.2696.3.2.1.9.7.1.2
This indicates whether the signal conforms to the spectrum mask
OBJECT-TYPE    
  TestState  

rfIfSpectrumEnable 1.3.6.1.4.1.2696.3.2.1.9.7.1.3
Determines whether the spectrum mask test and the associated trap are enabled.
OBJECT-TYPE    
  Enable  

rfIfSpectrumCounter 1.3.6.1.4.1.2696.3.2.1.9.7.1.4
Count of the number of times an error has occurred.
OBJECT-TYPE    
  Counter32  

rfIfSpectrumCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.7.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

rfIfSpectrumCounterReset 1.3.6.1.4.1.2696.3.2.1.9.7.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

rfIfSpectrumLatestError 1.3.6.1.4.1.2696.3.2.1.9.7.1.7
The timestamp at the most recent occurrence of an error.
OBJECT-TYPE    
  DateAndTime  

rfIfSpectrumActiveTime 1.3.6.1.4.1.2696.3.2.1.9.7.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNDT 1.3.6.1.4.1.2696.3.2.1.9.9
OBJECT IDENTIFIER    

eNDTTable 1.3.6.1.4.1.2696.3.2.1.9.9.1
Equivalent Noise Degradation measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the HP (high priority) stream. If the transmission is not hierarchical, this table contains the measurement for the whole stream.
OBJECT-TYPE    
  SEQUENCE OF  
    ENDTEntry

eNDTEntry 1.3.6.1.4.1.2696.3.2.1.9.9.1.1
Row specification
OBJECT-TYPE    
  ENDTEntry  

eNDTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

eNDTTestState 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.2
This indicates whether eNDTValue is within the thresholds.
OBJECT-TYPE    
  TestState  

eNDTEnable 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

eNDTCounter 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

eNDTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

eNDTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

eNDTLatestError 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

eNDTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNDTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

eNDTValue 1.3.6.1.4.1.2696.3.2.1.9.9.1.1.10
The current Equivalent Noise Degradation expressed in dB.
OBJECT-TYPE    
  FloatingPoint  

eNFTTable 1.3.6.1.4.1.2696.3.2.1.9.9.2
Equivalent Noise Floor measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the HP (high priority) stream. If the transmission is not hierarchical, this table contains the measurement for the whole stream.
OBJECT-TYPE    
  SEQUENCE OF  
    ENFTEntry

eNFTEntry 1.3.6.1.4.1.2696.3.2.1.9.9.2.1
Row specification
OBJECT-TYPE    
  ENFTEntry  

eNFTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

eNFTTestState 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.2
This indicates whether the eNFTValue is within the thresholds.
OBJECT-TYPE    
  TestState  

eNFTEnable 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

eNFTCounter 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

eNFTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

eNFTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

eNFTLatestError 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

eNFTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNFTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

eNFTValue 1.3.6.1.4.1.2696.3.2.1.9.9.2.1.10
The current Equivalent Noise Floor expressed in dB, see the reference for the method of calculation.
OBJECT-TYPE    
  FloatingPoint  

eNDTLPTable 1.3.6.1.4.1.2696.3.2.1.9.9.3
Equivalent Noise Degradation measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the LP (low priority) stream. If the transmission is not hierarchical, the MeasurementState for this table will be 'unknown'.
OBJECT-TYPE    
  SEQUENCE OF  
    ENDTLPEntry

eNDTLPEntry 1.3.6.1.4.1.2696.3.2.1.9.9.3.1
Row specification
OBJECT-TYPE    
  ENDTLPEntry  

eNDTLPInputNumber 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

eNDTLPTestState 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.2
This indicates whether eNDTLPValue is within the thresholds.
OBJECT-TYPE    
  TestState  

eNDTLPEnable 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

eNDTLPCounter 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

eNDTLPCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

eNDTLPCounterReset 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

eNDTLPLatestError 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

eNDTLPActiveTime 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNDTLPMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

eNDTLPValue 1.3.6.1.4.1.2696.3.2.1.9.9.3.1.10
The current Equivalent Noise Degradation for the low priority stream expressed in dB.
OBJECT-TYPE    
  FloatingPoint  

eNFTLPTable 1.3.6.1.4.1.2696.3.2.1.9.9.4
Equivalent Noise Floor measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the LP (low priority) stream. If the transmission is not hierarchical, the MeasurementState for this table will be 'unknown'.
OBJECT-TYPE    
  SEQUENCE OF  
    ENFTLPEntry

eNFTLPEntry 1.3.6.1.4.1.2696.3.2.1.9.9.4.1
Row specification
OBJECT-TYPE    
  ENFTLPEntry  

eNFTLPInputNumber 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

eNFTLPTestState 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.2
This indicates whether eNFTLPValue is within the thresholds.
OBJECT-TYPE    
  TestState  

eNFTLPEnable 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

eNFTLPCounter 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

eNFTLPCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

eNFTLPCounterReset 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

eNFTLPLatestError 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

eNFTLPActiveTime 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

eNFTLPMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

eNFTLPValue 1.3.6.1.4.1.2696.3.2.1.9.9.4.1.10
The current Equivalent Noise Floor for the low priority stream, expressed in dB, see the reference for the method of calculation.
OBJECT-TYPE    
  FloatingPoint  

linearityTable 1.3.6.1.4.1.2696.3.2.1.9.10
Linearity characterization (shoulder attenuation)
OBJECT-TYPE    
  SEQUENCE OF  
    LinearityEntry

linearityEntry 1.3.6.1.4.1.2696.3.2.1.9.10.1
Row specification
OBJECT-TYPE    
  LinearityEntry  

linearityInputNumber 1.3.6.1.4.1.2696.3.2.1.9.10.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

linearityTestState 1.3.6.1.4.1.2696.3.2.1.9.10.1.2
This indicates whether the linearityValue is above the minimum permitted.
OBJECT-TYPE    
  TestState  

linearityEnable 1.3.6.1.4.1.2696.3.2.1.9.10.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

linearityCounter 1.3.6.1.4.1.2696.3.2.1.9.10.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

linearityCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.10.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

linearityCounterReset 1.3.6.1.4.1.2696.3.2.1.9.10.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

linearityLatestError 1.3.6.1.4.1.2696.3.2.1.9.10.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

linearityActiveTime 1.3.6.1.4.1.2696.3.2.1.9.10.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

linearityMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.10.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

linearityValue 1.3.6.1.4.1.2696.3.2.1.9.10.1.10
The current linearity (shoulder attenuation) expressed in dB.
OBJECT-TYPE    
  FloatingPoint  

berViterbiT 1.3.6.1.4.1.2696.3.2.1.9.15
OBJECT IDENTIFIER    

berViterbiTTable 1.3.6.1.4.1.2696.3.2.1.9.15.1
BER before Viterbi measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the HP (high priority) stream. If the transmission is not hierarchical, this table contains the measurement for the whole stream.
OBJECT-TYPE    
  SEQUENCE OF  
    BerViterbiTEntry

berViterbiTEntry 1.3.6.1.4.1.2696.3.2.1.9.15.1.1
Row specification
OBJECT-TYPE    
  BerViterbiTEntry  

berViterbiTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berViterbiTTestState 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.2
This indicates whether the berViterbiTValue is within the thresholds.
OBJECT-TYPE    
  TestState  

berViterbiTEnable 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berViterbiTCounter 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berViterbiTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

berViterbiTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berViterbiTLatestError 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berViterbiTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berViterbiTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

berViterbiTValue 1.3.6.1.4.1.2696.3.2.1.9.15.1.1.10
This is the overall pre-Viterbi BER value, for example 0.0000046
OBJECT-TYPE    
  FloatingPoint  

berViterbiTLPTable 1.3.6.1.4.1.2696.3.2.1.9.15.2
BER before Viterbi measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the LP (low priority) stream. If the transmission is not hierarchical, the MeasurementState for this table will be 'unknown'.
OBJECT-TYPE    
  SEQUENCE OF  
    BerViterbiTLPEntry

berViterbiTLPEntry 1.3.6.1.4.1.2696.3.2.1.9.15.2.1
Row specification
OBJECT-TYPE    
  BerViterbiTLPEntry  

berViterbiTLPInputNumber 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berViterbiTLPTestState 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.2
This indicates whether the berViterbiTLPValue is within the thresholds.
OBJECT-TYPE    
  TestState  

berViterbiTLPEnable 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berViterbiTLPCounter 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berViterbiTLPCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

berViterbiTLPCounterReset 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berViterbiTLPLatestError 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berViterbiTLPActiveTime 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berViterbiTLPMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

berViterbiTLPValue 1.3.6.1.4.1.2696.3.2.1.9.15.2.1.10
This is the overall pre-Viterbi BER value, for example 0.0000046
OBJECT-TYPE    
  FloatingPoint  

berRS 1.3.6.1.4.1.2696.3.2.1.9.16
OBJECT IDENTIFIER    

berRSTable 1.3.6.1.4.1.2696.3.2.1.9.16.1
BER before RS measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the HP (high priority) stream. If the transmission is not hierarchical, this table contains the measurement for the whole stream.
OBJECT-TYPE    
  SEQUENCE OF  
    BerRSEntry

berRSEntry 1.3.6.1.4.1.2696.3.2.1.9.16.1.1
Row specification
OBJECT-TYPE    
  BerRSEntry  

berRSInputNumber 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berRSTestState 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.2
This indicates whether berRSValue is below the maximum.
OBJECT-TYPE    
  TestState  

berRSEnable 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berRSCounter 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berRSCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

berRSCounterReset 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berRSLatestError 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berRSActiveTime 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berRSMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

berRSValue 1.3.6.1.4.1.2696.3.2.1.9.16.1.1.10
This is the BER before RS (outer) decoder measured using the in-service method. It is expressed as a number, e.g. 0.0000034
OBJECT-TYPE    
  FloatingPoint  

berRSLPTable 1.3.6.1.4.1.2696.3.2.1.9.16.2
BER before RS measurement. If the DVB-T transmission is hierarchical, this table contains the measurement for the LP (low priority) stream. If the transmission is not hierarchical, the MeasurementState for this table will be 'unknown'.
OBJECT-TYPE    
  SEQUENCE OF  
    BerRSLPEntry

berRSLPEntry 1.3.6.1.4.1.2696.3.2.1.9.16.2.1
Row specification
OBJECT-TYPE    
  BerRSLPEntry  

berRSLPInputNumber 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

berRSLPTestState 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.2
This indicates whether berRSLPValue is within the thresholds.
OBJECT-TYPE    
  TestState  

berRSLPEnable 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

berRSLPCounter 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

berRSLPCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

berRSLPCounterReset 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

berRSLPLatestError 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

berRSLPActiveTime 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

berRSLPMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

berRSLPValue 1.3.6.1.4.1.2696.3.2.1.9.16.2.1.10
This is the BER before RS (outer) decoder for the low priority stream measured using the in-service method. It is expressed as a number, e.g. 0.0000034
OBJECT-TYPE    
  FloatingPoint  

iqAnalysisT 1.3.6.1.4.1.2696.3.2.1.9.18
OBJECT IDENTIFIER    

merTTable 1.3.6.1.4.1.2696.3.2.1.9.18.2
Modulation Error Ratio (MER) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    MerTEntry

merTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.2.1
Row specification
OBJECT-TYPE    
  MerTEntry  

merTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

merTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.2
This indicates whether merTValue is within the thresholds.
OBJECT-TYPE    
  TestState  

merTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

merTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

merTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.5
Provides the last time at which there was a discontinuity in the merTCounter object.
OBJECT-TYPE    
  DateAndTime  

merTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

merTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

merTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

merTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

merTValue 1.3.6.1.4.1.2696.3.2.1.9.18.2.1.10
The current Modulation Error Ratio expressed in dB
OBJECT-TYPE    
  FloatingPoint  

steT 1.3.6.1.4.1.2696.3.2.1.9.18.3
OBJECT IDENTIFIER    

steMeanTTable 1.3.6.1.4.1.2696.3.2.1.9.18.3.1
System Target Error Mean (STEM) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    SteMeanTEntry

steMeanTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1
Row specification
OBJECT-TYPE    
  SteMeanTEntry  

steMeanTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

steMeanTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.2
This indicates whether steMeanTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

steMeanTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

steMeanTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

steMeanTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

steMeanTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

steMeanTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

steMeanTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

steMeanTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

steMeanTValue 1.3.6.1.4.1.2696.3.2.1.9.18.3.1.1.10
The current System Target Error Mean as a numeric value
OBJECT-TYPE    
  FloatingPoint  

steDeviationTTable 1.3.6.1.4.1.2696.3.2.1.9.18.3.2
System Target Error Deviation (STED) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    SteDeviationTEntry

steDeviationTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1
Row specification
OBJECT-TYPE    
  SteDeviationTEntry  

steDeviationTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

steDeviationTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.2
This indicates whether steDeviationTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

steDeviationTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

steDeviationTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

steDeviationTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

steDeviationTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

steDeviationTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

steDeviationTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

steDeviationTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

steDeviationTValue 1.3.6.1.4.1.2696.3.2.1.9.18.3.2.1.10
The current System Target Error Deviation as a numeric value
OBJECT-TYPE    
  FloatingPoint  

csTTable 1.3.6.1.4.1.2696.3.2.1.9.18.4
Carrier Suppression (CS) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    CsTEntry

csTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.4.1
Row specification
OBJECT-TYPE    
  CsTEntry  

csTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

csTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.2
This indicates whether csTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

csTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

csTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

csTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

csTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

csTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

csTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

csTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

csTValue 1.3.6.1.4.1.2696.3.2.1.9.18.4.1.10
The current Carrier Suppression value in dB.
OBJECT-TYPE    
  FloatingPoint  

aiTTable 1.3.6.1.4.1.2696.3.2.1.9.18.5
Amplitude Imbalance (AI) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    AiTEntry

aiTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.5.1
Row specification
OBJECT-TYPE    
  AiTEntry  

aiTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

aiTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.2
This indicates whether aiTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

aiTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

aiTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

aiTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

aiTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

aiTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

aiTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

aiTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

aiTValue 1.3.6.1.4.1.2696.3.2.1.9.18.5.1.10
The current Amplitude Imbalance as a percentage
OBJECT-TYPE    
  FloatingPoint  

qeTTable 1.3.6.1.4.1.2696.3.2.1.9.18.6
Quadrature Error (QE) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    QeTEntry

qeTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.6.1
Row specification
OBJECT-TYPE    
  QeTEntry  

qeTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

qeTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.2
This indicates whether qeTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

qeTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

qeTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

qeTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

qeTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

qeTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

qeTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

qeTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

qeTValue 1.3.6.1.4.1.2696.3.2.1.9.18.6.1.10
The current Quadrature Error value in degrees.
OBJECT-TYPE    
  FloatingPoint  

pjTTable 1.3.6.1.4.1.2696.3.2.1.9.18.7
Phase Jitter (PJ) measurement
OBJECT-TYPE    
  SEQUENCE OF  
    PjTEntry

pjTEntry 1.3.6.1.4.1.2696.3.2.1.9.18.7.1
Row specification
OBJECT-TYPE    
  PjTEntry  

pjTInputNumber 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

pjTTestState 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.2
This indicates whether pjTValue is currently within the thresholds.
OBJECT-TYPE    
  TestState  

pjTEnable 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

pjTCounter 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.4
Count of the number of times a threshold error has occurred for this measurement.
OBJECT-TYPE    
  Counter32  

pjTCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

pjTCounterReset 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

pjTLatestError 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.7
The timestamp at the most recent occurrence of a threshold error on this measurement.
OBJECT-TYPE    
  DateAndTime  

pjTActiveTime 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

pjTMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

pjTValue 1.3.6.1.4.1.2696.3.2.1.9.18.7.1.10
The current Phase Jitter value in degrees.
OBJECT-TYPE    
  FloatingPoint  

mipSyntaxTable 1.3.6.1.4.1.2696.3.2.1.9.20
SFN MIP baseband tests
OBJECT-TYPE    
  SEQUENCE OF  
    MipSyntaxEntry

mipSyntaxEntry 1.3.6.1.4.1.2696.3.2.1.9.20.1
Row specification
OBJECT-TYPE    
  MipSyntaxEntry  

mipSyntaxInputNumber 1.3.6.1.4.1.2696.3.2.1.9.20.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

mipSyntaxTestNumber 1.3.6.1.4.1.2696.3.2.1.9.20.1.2
The specific SFN MIP test that this row applies to
OBJECT-TYPE    
  IndexMIPSyntaxTest  

mipSyntaxState 1.3.6.1.4.1.2696.3.2.1.9.20.1.3
This gives the overall pass/fail state of the test.
OBJECT-TYPE    
  TestState  

mipSyntaxEnable 1.3.6.1.4.1.2696.3.2.1.9.20.1.4
Determines whether this test and the associated trap are enabled.
OBJECT-TYPE    
  Enable  

mipSyntaxCounter 1.3.6.1.4.1.2696.3.2.1.9.20.1.5
Count of the number of times this error has occurred
OBJECT-TYPE    
  Counter32  

mipSyntaxCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.20.1.6
Provides the last time at which there was a discontinuity in the mipSyntaxCounter object.
OBJECT-TYPE    
  DateAndTime  

mipSyntaxCounterReset 1.3.6.1.4.1.2696.3.2.1.9.20.1.7
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

mipSyntaxLatestError 1.3.6.1.4.1.2696.3.2.1.9.20.1.8
The timestamp at the most recent occurrence of the error
OBJECT-TYPE    
  DateAndTime  

mipSyntaxActiveTime 1.3.6.1.4.1.2696.3.2.1.9.20.1.9
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

systemErrorPerformance 1.3.6.1.4.1.2696.3.2.1.9.21
OBJECT IDENTIFIER    

sepEtiTable 1.3.6.1.4.1.2696.3.2.1.9.21.1
Measurement of Errored Second Ratio (ESR) or Errored Time Interval Ratio (ETIR).
OBJECT-TYPE    
  SEQUENCE OF  
    SepEtiEntry

sepEtiEntry 1.3.6.1.4.1.2696.3.2.1.9.21.1.1
Row specification
OBJECT-TYPE    
  SepEtiEntry  

sepEtiInputNumber 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

sepEtiTestState 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.2
A 'fail' indicaties that the most recently completed time interval TI was an Errored Time Interval (ETI). A 'pass' indicates that the most recent TI was not errored.
OBJECT-TYPE    
  TestState  

sepEtiEnable 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

sepEtiCounter 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.4
Count of the number of times an ETI has occurred.
OBJECT-TYPE    
  Counter32  

sepEtiCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

sepEtiCounterReset 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

sepEtiLatestError 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.7
The timestamp at the most recent occurrence of an ETI.
OBJECT-TYPE    
  DateAndTime  

sepEtiActiveTime 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

sepEtiMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

sepEtiValue 1.3.6.1.4.1.2696.3.2.1.9.21.1.1.10
This is the Errored Time Interval Ratio (ETIR) for the most recently completed Measurement Interval (MI). It is expressed as a numeric value.
OBJECT-TYPE    
  FloatingPoint  

sepSetiTable 1.3.6.1.4.1.2696.3.2.1.9.21.2
Measurement of Severly Errored Second Ratio (SESR) or Severely Errored Time Interval Ratio (SETIR).
OBJECT-TYPE    
  SEQUENCE OF  
    SepSetiEntry

sepSetiEntry 1.3.6.1.4.1.2696.3.2.1.9.21.2.1
Row specification
OBJECT-TYPE    
  SepSetiEntry  

sepSetiInputNumber 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.1
Transport Stream on which the measurement is made
OBJECT-TYPE    
  InputNumber  

sepSetiTestState 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.2
A 'fail' indicaties that the most recently completed time interval TI was a Severely Errored Time Interval (SETI). A 'pass' indicates that the most recent TI was not severely errored.
OBJECT-TYPE    
  TestState  

sepSetiEnable 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.3
Determines whether the threshold test and associated traps for this measurement are enabled.
OBJECT-TYPE    
  Enable  

sepSetiCounter 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.4
Count of the number of times an SETI has occurred.
OBJECT-TYPE    
  Counter32  

sepSetiCounterDiscontinuity 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.5
Provides the last time at which there was a discontinuity in the counter object.
OBJECT-TYPE    
  DateAndTime  

sepSetiCounterReset 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.6
The counter object is reset to zero and the counter discontinuity object is set to the current time if 'true' is written to this object. When read, the value of this object is always 'false'.
OBJECT-TYPE    
  TruthValue  

sepSetiLatestError 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.7
The timestamp at the most recent occurrence of a SETI.
OBJECT-TYPE    
  DateAndTime  

sepSetiActiveTime 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.8
The total time when it has been possible to perform this measurement
OBJECT-TYPE    
  ActiveTime  

sepSetiMeasurementState 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.9
Specifies the validity of the measurement value
OBJECT-TYPE    
  MeasurementState  

sepSetiValue 1.3.6.1.4.1.2696.3.2.1.9.21.2.1.10
This is the Severely Errored Time Interval Ratio (SETIR) for the most recently completed Measurement Interval (MI). It is expressed as a numeric value.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPreferencesTable 1.3.6.1.4.1.2696.3.2.1.9.100
Table of terrestrial specific measurement preferences.
OBJECT-TYPE    
  SEQUENCE OF  
    TerrestrialPreferencesEntry

terrestrialPreferencesEntry 1.3.6.1.4.1.2696.3.2.1.9.100.1
Row specification
OBJECT-TYPE    
  TerrestrialPreferencesEntry  

terrestrialPrefInputNumber 1.3.6.1.4.1.2696.3.2.1.9.100.1.1
Transport Stream input to which the preferences apply
OBJECT-TYPE    
  InputNumber  

terrestrialPrefCentreFrequency 1.3.6.1.4.1.2696.3.2.1.9.100.1.2
This is the centre frequency to which the measuring equipment is tuned for making terrestrial measurements. This frequency is the actual input frequency to the measuring equipment, which may be at an intermediate frequency (IF) rather than the final RF.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefBandwidth 1.3.6.1.4.1.2696.3.2.1.9.100.1.3
The instrument is set to expect a DVB-T transmission adapted for this bandwidth. Normal values will be 6.0MHz, 7.0MHz or 8.0MHz.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefModulation 1.3.6.1.4.1.2696.3.2.1.9.100.1.4
This is the modulation which the measuring equipment expects to see and against which it makes modulation measurements. This applies to terrestrial measurements.
OBJECT-TYPE    
  Modulation  

terrestrialPrefTransmissionMode 1.3.6.1.4.1.2696.3.2.1.9.100.1.5
The instrument is set to expect a transmission in either 2k mode or 8k mode as set by this object.
OBJECT-TYPE    
  TerrestrialTransmissionMode  

terrestrialPrefGuardInterval 1.3.6.1.4.1.2696.3.2.1.9.100.1.6
The instrument is set to expect a transmission using the guard interval specified by this object.
OBJECT-TYPE    
  GuardInterval  

terrestrialPrefHierarchical 1.3.6.1.4.1.2696.3.2.1.9.100.1.7
The instrument is set according to the value of this object to expect a transmission which is either non-hierachical or hierarchical using the specified alpha value.
OBJECT-TYPE    
  Hierarchy  

terrestrialPrefCentreFreqExpected 1.3.6.1.4.1.2696.3.2.1.9.100.1.8
This is the expected value for the centre frequency as measured by rfAccuracyValue.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefCentreFreqLimit 1.3.6.1.4.1.2696.3.2.1.9.100.1.9
This is the permitted deviation for the centre frequency as measured by rfAccuracyValue. If rfAccuracyValue is outside the range: [terrestrialPrefCentreFreqExpected - terrestrialPrefCentreFreqLimit .. terrestrialPrefCentreFreqExpected + terrestrialPrefCentreFreqLimit] an error will be indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefChannelWidthLimit 1.3.6.1.4.1.2696.3.2.1.9.100.1.10
This is the permitted deviation for the channel width as measured by rfChannelWidthValue. The nominal value of the channel width has a fixed value which depends on the bandwidth (as set by terrestrialPrefBandwidth). If rfChannelWidthValue is outside the range [nominalWidth - terrestrialPrefChannelWidthLimit .. nominalWidth + terrestrialPrefChannelWidthLimit] an error will be indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSymbolLengthLimit 1.3.6.1.4.1.2696.3.2.1.9.100.1.11
This is the permitted deviation for the symbol length as measured by symbolLengthValue. The nominal value of the symbol length has a fixed value which depends on the bandwidth, the mode and the guard interval (as set by terrestrialPrefBandwidth, terrestrialPrefTransmissionMode and terrestrialPrefGuardInterval respectively). If symbolLengthValue is outside the range [nominalLength - terrestrialPrefSymbolLengthLimit .. nominalLength + terrestrialPrefSymbolLengthLimit] an error will be indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefPowerMin 1.3.6.1.4.1.2696.3.2.1.9.100.1.12
If the power measured by rfIfPowerValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefPowerMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.13
If the power measured by rfIfPowerValue is greater than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENDBER 1.3.6.1.4.1.2696.3.2.1.9.100.1.14
BER value which is to be used for the END and ENF measurements.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENDIdeal 1.3.6.1.4.1.2696.3.2.1.9.100.1.15
This is the 'ideal' value of C/N for measurement of END on the whole or high priority stream. It is used in the measurement of eNDTValue.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENDMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.16
If the measured value of eNDTValue exceeds this, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENFIdeal 1.3.6.1.4.1.2696.3.2.1.9.100.1.17
This is the 'ideal' value of C/N for measurement of ENF on the whole or high priority stream. It is used in the measurement of eNFTValue.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENFMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.18
If the measured value of eNFTValue is exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENDLPIdeal 1.3.6.1.4.1.2696.3.2.1.9.100.1.19
This is the 'ideal' value of C/N for measurement of END on the low priority stream. It is used in the measurement of eNDTLPValue.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENDLPMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.20
If the measured value of eNDTLPValue exceeds this, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENFLPIdeal 1.3.6.1.4.1.2696.3.2.1.9.100.1.21
This is the 'ideal' value of C/N for measurement of ENF on the low priority stream. It is used in the measurement of eNFTLPValue.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefENFLPMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.22
If the measured value of eNFTLPValue exeeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefLinearityMin 1.3.6.1.4.1.2696.3.2.1.9.100.1.23
If the shoulder attenuation as measured by linearityValue is less than this value, an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefBERViterbiMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.24
If the BER measured by berViterbiTValue exceeds this value, an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefBERViterbiLPMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.25
If the BER measured by berViterbiTLPValue exceeds this value, an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefBERRSMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.26
If the BER measured by berRSValue exceeds this value, an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefBERRSLPMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.27
If the BER measured by berRSLPValue exceeds this value, an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefMerTMin 1.3.6.1.4.1.2696.3.2.1.9.100.1.28
If merTValue is less than this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSteMeanMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.29
If steMeanTValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSteDeviationMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.30
If steDeviationTValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefCsMin 1.3.6.1.4.1.2696.3.2.1.9.100.1.31
If csTValue is less than this value, the associated test fails
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefAiMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.32
If aiTValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefQeMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.33
If qeTValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefPjMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.34
If pjTValue exceeds this value, the associated test fails.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefMIPTimingLimit 1.3.6.1.4.1.2696.3.2.1.9.100.1.35
This preference affects the MIP_timing_error test. If the calculated value of nT differs from an integral number of seconds by more than terrestrialPrefMIPTimingLimit then an error is indicated.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefMIPDeviationMax 1.3.6.1.4.1.2696.3.2.1.9.100.1.36
This preference affects the MIP_ts_rate_error test. It is the value of Max_deviation in the inequality given in TR 101 290 as the condition for an error indication.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSEPUATMode 1.3.6.1.4.1.2696.3.2.1.9.100.1.37
Determines whether the 'N consecutive' or 'rolling window' mode of determining the start of a period of Unavailable Time (UAT) is used. If the 'N consecutive' mode is selected, the 'M' and 'T' preference parameters are ignored. Likewise, if the 'rolling window' mode is selected, the 'N' preference parameter is ignored.
OBJECT-TYPE    
  UATMode  

terrestrialPrefSEPN 1.3.6.1.4.1.2696.3.2.1.9.100.1.38
The N value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  Unsigned32  

terrestrialPrefSEPT 1.3.6.1.4.1.2696.3.2.1.9.100.1.39
The T value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSEPM 1.3.6.1.4.1.2696.3.2.1.9.100.1.40
The M value used to identify the start and end of a period of unavailable time (UAT).
OBJECT-TYPE    
  Unsigned32  

terrestrialPrefSEPTI 1.3.6.1.4.1.2696.3.2.1.9.100.1.41
Each Time Interval of this length is assessed as to whether it is an Errored Time Interval or a Severely Errored Time Interval.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSEPEBPerCent 1.3.6.1.4.1.2696.3.2.1.9.100.1.42
If more than this percentage of blocks within a Time Interval is an Errored Block, the Time Interval is a Severely Errored Time Interval (SETI). Example values are: '1.53', '10', '0.33'.
OBJECT-TYPE    
  FloatingPoint  

terrestrialPrefSEPMeasurementInterval 1.3.6.1.4.1.2696.3.2.1.9.100.1.43
The Measurement Interval (MI) over which the ESR/ETIR and SESR/SETIR are calculated.
OBJECT-TYPE    
  FloatingPoint  

tr101290Conformance 1.3.6.1.4.1.2696.3.2.3
OBJECT IDENTIFIER    

tr101290Compliances 1.3.6.1.4.1.2696.3.2.3.1
OBJECT IDENTIFIER    

complianceTransportStream 1.3.6.1.4.1.2696.3.2.3.1.1
Compliance for Transport Stream monitor devices
MODULE-COMPLIANCE    

complianceCable 1.3.6.1.4.1.2696.3.2.3.1.2
Compliance for Cable RF measurement devices
MODULE-COMPLIANCE    

complianceSatellite 1.3.6.1.4.1.2696.3.2.3.1.3
Compliance for Satellite RF measurement devices
MODULE-COMPLIANCE    

complianceTerrestrial 1.3.6.1.4.1.2696.3.2.3.1.4
Compliance for Terrestrial RF measurement devices
MODULE-COMPLIANCE    

tr101290ObjectGroups 1.3.6.1.4.1.2696.3.2.3.2
OBJECT IDENTIFIER    

groupControl 1.3.6.1.4.1.2696.3.2.3.2.1
Contains all the objects from the tr101290Control branch of the MIB
OBJECT-GROUP    

groupTrapControl 1.3.6.1.4.1.2696.3.2.3.2.2
Contains all the normal objects from the tr101290Trap branch of the MIB
OBJECT-GROUP    

groupTraps 1.3.6.1.4.1.2696.3.2.3.2.3
Contains all the traps/notifications from the MIB.
NOTIFICATION-GROUP    

groupCapability 1.3.6.1.4.1.2696.3.2.3.2.4
Contains all objects from the tr101290Capability branch of the MIB
OBJECT-GROUP    

groupTransportStream 1.3.6.1.4.1.2696.3.2.3.2.5
Contains all objects relevant to Transport Stream measurement
OBJECT-GROUP    

groupCable 1.3.6.1.4.1.2696.3.2.3.2.6
Contains all objects relevant to cable RF measurement
OBJECT-GROUP    

groupSatellite 1.3.6.1.4.1.2696.3.2.3.2.7
Contains all objects relevent to satellite RF measurements
OBJECT-GROUP    

groupTerrestrial 1.3.6.1.4.1.2696.3.2.3.2.8
Contains all objects relevant to terrestrial RF measurements
OBJECT-GROUP    

Defined Objects

ActiveTime  
This is a monotonically increasing value in units of seconds that represents the total amount of time for which the instrument has been able to perform a particular test or measurement. The instrument might not be performing the test because some other error condition prevented it, because it was operating in a polled mode where it looked at one input at a time or because it had been placed in an inactive state for a while. 'Able to perform the test' corresponds to the TestState being either 'pass' or 'fail'. The existence of this attribute allows a management system to calculate a realistic errors per second value for any test.
TEXTUAL-CONVENTION    
  Unsigned32  

Availability  
Availability is used in the capabilities branch of the MIB to indicate whether the instrument is equipped to provide a specific test and/or measurement.
TEXTUAL-CONVENTION    
  INTEGER notAvailable(1), testAvailable(2), measurementAvailable(3), measurementAndTestAvailable(4)  

BERMeasurementMethod  
Indicates the method used for measuring BER before Viterbi decoding
TEXTUAL-CONVENTION    
  INTEGER iqSeparate(1), iqCombined(2)  

BitRateElement  
The fundamental data unit that is being counted by the bit rate measurement algorithm.
TEXTUAL-CONVENTION    
  INTEGER bit(1), byte(2), packet(3), other(4)  

DeliverySystemType  
Specifies the physical delivery system used for a Transport Stream.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), cable(2), satellite(3), terrestrial(4)  

Enable  
This type is used for the '...Enable' objects of tests and measurements. It determines whether the test is enabled and also which traps can be generated by this test/measurement. If the testEnable bit is zero, the test will not be performed and the failTrapEnable bit is ignored. If the testEnable bit is one, the test will be performed. Additionally, a testFailTrap or measurementFailTrap will be sent when the test state becomes 'fail'. The 'unknownTrapEnable' bit is only relevant to measurements. If it is set to one, a 'measurementUnknownTrap' will be sent when the '...MeasurementState' object becomes 'unknown'.
TEXTUAL-CONVENTION    
  BITS testEnable(0), failTrapEnable(1), unknownTrapEnable(2)  

FloatingPoint  
FloatingPoint provides a way of representing non-integer numbers in SNMP. Numbers are represented as a string of ASCII characters in the natural way. So for example, '3', '3.142' and '0.3142E1' are all valid numbers. The syntax for the string is as follows. [] enclose an optional element, | is the separator for a set of alternatives. () enclose syntax which is to be viewed as a unit. FloatingPoint ::= [Sign] (Float1 | Float2 | DigitSequence) [ExponentPart] Float1 ::= DigitSequence '.' [DigitSequence] Float2 ::= '.' DigitSequence DigitSequence ::= Digit [DigitSequence] ExponentPart ::= ('e' | 'E') [Sign] DigitSequence Digit ::= '0'..'9' Sign ::= '+' | '-'
TEXTUAL-CONVENTION    
  OCTET STRING SIZE(1..63)  

GroupAvailability  
This is used in the tr101290Capability branch of the MIB to specify an agent's degree of support for a whole branch of the MIB. The individual values mean: noSupport no objects in this branch are available selectiveSupport some but not all objects are available, refer to the test table for further details completeSupport all objects defined in the stated revision of the MIB are available
TEXTUAL-CONVENTION    
  INTEGER noSupport(1), selectiveSupport(2), completeSupport(3)  

GuardInterval  
Guard intervals as specified for DVB-T transmissions. interval1d4 means a guard interval of 1/4.
TEXTUAL-CONVENTION    
  INTEGER interval1d4(1), interval1d8(2), interval1d16(3), interval1d32(4)  

Hierarchy  
In DVB-T systems this is used to specify whether the transmission is hierarchical, and if so, the value of alpha.
TEXTUAL-CONVENTION    
  INTEGER nonHierarchical(1), hierarchicalAlphaOne(2), hierarchicalAphaTwo(3), hierarchicalAlphaFour(4)  

IndexConsistencyTest  
Index of consistency check tests
TEXTUAL-CONVENTION    
  INTEGER tsIdCheck(1)  

IndexMIPSyntaxTest  
This assigns numbers to the MIP syntax tests. These numbers are then used as indexes into the MIP syntax table.
TEXTUAL-CONVENTION    
  INTEGER mipTimingError(1), mipStructureError(2), mipPresenceError(3), mipPointerError(4), mipPeriodicityError(5), mipTsRateError(6)  

IndexPCRMeasurement  
This assigns numbers to the PCR measurements. These numbers are then used as indexes into the PCR measurement table.
TEXTUAL-CONVENTION    
  INTEGER pcrFO(1), pcrDR(2), pcrOJ(3), pcrAC(4)  

IndexServicePerformance  
This assigns numbers to the Service Performance measurements. These numbers are then used as indexes into the Service Performance measurement table.
TEXTUAL-CONVENTION    
  INTEGER serviceAvailability(1), serviceDegradation(2), serviceImpairments(3)  

IndexTransportStreamTest  
IndexTransportStreamTest assigns a unique numerical value to each of the TR 101 290 Transport Stream tests in section 5.2. The number allocated is: priority * 1000 + test number * 10 + subtest Subtest is zero if there is no subtest. Subtest 'a' is numbered 1, 'b' is numbered 2 etc. The enumeration names are derived directly from the test names in TR 101 290 taking into account the syntax requirements of the MIB.
TEXTUAL-CONVENTION    
  INTEGER tsSyncLoss(1010), syncByteError(1020), patError2(1031), continuityCountError(1040), pmtError2(1051), pidError(1060), transportError(2010), crcError(2020), pcrRepetitionError(2031), pcrDiscontinuityError(2032), pcrAccuracyError(2040), ptsError(2050), catError(2060), nitActualError(3011), nitOtherError(3012), siRepetitionError(3020), bufferError(3030), unreferencedPID(3041), sdtActualError(3051), sdtOtherError(3052), eitActualError(3061), eitOtherError(3062), eitPfError(3063), rstError(3070), tdtError(3080), emptyBufferError(3090), dataDelayError(3100)  

InputNumber  
InputNumber objects are used to select a specific Transport Stream input on a multi-input monitoring/measurement device. On a single input monitoring/measuring device, InputNumber objects will always have the value one.
TEXTUAL-CONVENTION    
  INTEGER 1..2147483647  

MeasurementState  
MeasurementState is used to represent the state of a single measurement. 'disabled' means that the measurement has been disabled by setting the 'testEnable' bit in its ...Enable object to zero. 'unknown' means that the equipment cannot provide a value because of temporary circumstances, for example some other signal condition makes this measurement impossible. 'abnormal' means that the measurement value is incorrect for reasons connected with that measurement itself. For example the measurement may be out of range. A measurement value is still provided and users or managers with knowledge of the behaviour of this specific measuring equipment may be able to interpret the value. 'normal' means that the measurement is enabled and has been evaluated.
TEXTUAL-CONVENTION    
  INTEGER disabled(1), unknown(2), normal(3), abnormal(4)  

Modulation  
Modulation systems used in RF transmissions
TEXTUAL-CONVENTION    
  INTEGER bpsk(1), qpsk(2), psk8(3), qam16(4), qam32(5), qam64(6), qam128(7), qam256(8), qam16Alpha2(9), qam64Alpha2(10), qam16Alpha4(11), qam64Alpha4(12)  

PIDPlusOne  
An object of type PIDPlusOne represents an MPEG-2 PID number. The numeric value of the object is the PID + 1, to allow for its use as a table index.
TEXTUAL-CONVENTION    
  INTEGER 1..8192  

PollingInterval  
Objects of this type are used by the agent to indicate how often it internally updates the information related to a particular test or measurement. The manager can then adjust its polling behaviour accordingly. The polling interval should be interpreted by the manager as approximate. In practice the agent may update the information faster or slower than indicated depending on the circumstances. The meaning of the value is: positive - represents a normal value in milliseconds zero - the value is updated continuously negative - unknown or not applicable
TEXTUAL-CONVENTION    
  Integer32  

RateStatus  
RateStatus is used in trap control
TEXTUAL-CONVENTION    
  INTEGER disabled(1), enabled(2), enabledThrottled(3)  

ServiceId  
Allowed values of program_number/service_id. Note that zero is used in the PAT to represent the NIT PID and so will never occur as a service_id.
TEXTUAL-CONVENTION    
  INTEGER 1..65535  

TerrestrialTransmissionMode  
Transmission mode for DVB-T transmissions, specifies whether there are 2k or 8k carriers.
TEXTUAL-CONVENTION    
  INTEGER mode2k(1), mode8k(2)  

TestState  
TestState is used to represent the state of a single test. 'disabled' means that the test has been disabled by setting the 'testEnable' bit of its ...Enable variable to zero. 'unknown' means that the equipment cannot provide a value for the state because of temporary circumstances (for example some other error makes this test impossible to evaluate). 'pass' means that the test is enabled, can be evaluated and is not failing. For a 'Status error', 'fail' means that the state of the input is currently in error. For an 'Event error', 'fail' means that an error event has occurred within the most recent persistence interval as defined by the 'controlEventPersistence' object.
TEXTUAL-CONVENTION    
  INTEGER disabled(1), unknown(2), pass(3), fail(4)  

TestSummary  
Bit String providing a status summary for all the tests defined in this MIB module. A bit is set to one if the state of that test is 'fail'. In several cases, a single bit summarises the results of a set of tests. In that case, if the state of any of the tests is 'fail', the bit is set to one. An example of this is 'bitratePID' where the single bit summarises whether all the PID bitrates are within range. To aid identification, the bits are numbered in the order in which the associated tests appear in the MIB. Other than this, there is no connection between the bit number and the OID of the test.
TEXTUAL-CONVENTION    
  BITS tsTsSyncLoss(0), tsSyncByteError(1), tsPatError2(2), tsContinuityCountError(3), tsPmtError2(4), tsPidError(5), tsTransportError(6), tsCrcError(7), tsPcrRepetitionError(8), tsPcrDiscontinuityError(9), tsPcrAccuracyError(10), tsPtsError(11), tsCatError(12), tsNitActualError(13), tsNitOtherError(14), tsSiRepetitionError(15), tsBufferError(16), tsUnreferencedPID(17), tsSdtActualError(18), tsSdtOtherError(19), tsEitActualError(20), tsEitOtherError(21), tsEitPfError(22), tsRstError(23), tsTdtError(24), tsEmptyBufferError(25), tsDataDelayError(26), pcrPcrFO(27), pcrPcrDR(28), pcrPcrOJ(29), pcrPcrAC(30), bitrateTransportStream(31), bitrateService(32), bitratePID(33), tsTsConsistency(34), performanceServiceAvailability(35), performanceServiceDegradation(36), performanceServiceImpairments(37), csSysAvailability(38), csLinkAvailability(39), csBerRS(40), csRFIFSignalPower(41), csNoisePower(42), csMer(43), csSteMean(44), csSteDeviation(45), csCS(46), csAI(47), csQE(48), csRTE(49), csCI(50), csPJ(51), csSNR(52), cNoiseMargin(53), cEstNoiseMargin(54), cSignQualMarT(55), cEND(56), cOutBandEmiss(57), sBerViterbi(58), sIfSpectrum(59), tRFAccuracy(60), tRFChannelWidth(61), tSymbolLength(62), tRFIFPower(63), tRFIFSpectrum(64), tEND(65), tENF(66), tENDLP(67), tENFLP(68), tLinearity(69), tBerViterbi(70), tBerViterbiLP(71), tBerRS(72), tBerRSLP(73), tMER(74), tSteMean(75), tSteDeviation(76), tCS(77), tAI(78), tQE(79), tPJ(80), tMipTimingError(81), tMipStructureError(82), tMipPresenceError(83), tMipPointerError(84), tMipPeriodicityError(85), tMipTsRateError(86), tSepEti(87), tSepSeti(88)  

TransportStreamID  
Range of possible values for a transport_stream_id as found in the PAT.
TEXTUAL-CONVENTION    
  INTEGER 0..65535  

UATMode  
Method of determining the start and end of a period of Unavailable Time.
TEXTUAL-CONVENTION    
  INTEGER nConsecutive(1), rollingWindow(2)  

ControlRFSystemEntry  
SEQUENCE    
  InputNumber as rfSystemInputNumber  
  DeliverySystemType as rfSystemDelivery  

ControlSynchronizationEntry  
SEQUENCE    
  InputNumber as controlSynchronizationInputNumber  
  FloatingPoint as controlSynchronizedTime  

TrapControlEntry  
SEQUENCE    
  InputNumber as trapControlInputNumber  
  OBJECT IDENTIFIER as trapControlOID  
  DateAndTime as trapControlGenerationTime  
  FloatingPoint as trapControlMeasurementValue  
  RateStatus as trapControlRateStatus  
  Unsigned32 as trapControlPeriod  
  TestSummary as trapControlFailureSummary  

CapabilityTSEntry  
SEQUENCE    
  OBJECT IDENTIFIER as capabilityTSOID  
  Availability as capabilityTSAvailability  
  PollingInterval as capabilityTSPollInterval  

CapabilityCableSatEntry  
SEQUENCE    
  OBJECT IDENTIFIER as capabilityCableSatOID  
  Availability as capabilityCableSatAvailability  
  PollingInterval as capabilityCableSatPollInterval  

CapabilityCableEntry  
SEQUENCE    
  OBJECT IDENTIFIER as capabilityCableOID  
  Availability as capabilityCableAvailability  
  PollingInterval as capabilityCablePollInterval  

CapabilitySatelliteEntry  
SEQUENCE    
  OBJECT IDENTIFIER as capabilitySatelliteOID  
  Availability as capabilitySatelliteAvailability  
  PollingInterval as capabilitySatellitePollInterval  

CapabilityTerrestrialEntry  
SEQUENCE    
  OBJECT IDENTIFIER as capabilityTerrestrialOID  
  Availability as capabilityTerrestrialAvailability  
  PollingInterval as capabilityTerrestrialPollInterval  

TsTestsSummaryEntry  
SEQUENCE    
  InputNumber as tsTestsSummaryInputNumber  
  IndexTransportStreamTest as tsTestsSummaryTestNumber  
  TestState as tsTestsSummaryState  
  Enable as tsTestsSummaryEnable  
  Counter32 as tsTestsSummaryCounter  
  DateAndTime as tsTestsSummaryCounterDiscontinuity  
  TruthValue as tsTestsSummaryCounterReset  
  DateAndTime as tsTestsSummaryLatestError  
  ActiveTime as tsTestsSummaryActiveTime  

TsTestsPIDEntry  
SEQUENCE    
  InputNumber as tsTestsPIDInputNumber  
  PIDPlusOne as tsTestsPIDPID  
  IndexTransportStreamTest as tsTestsPIDTestNumber  
  RowStatus as tsTestsPIDRowStatus  
  TestState as tsTestsPIDState  
  Enable as tsTestsPIDEnable  
  Counter32 as tsTestsPIDCounter  
  DateAndTime as tsTestsPIDCounterDiscontinuity  
  TruthValue as tsTestsPIDCounterReset  
  DateAndTime as tsTestsPIDLatestError  
  ActiveTime as tsTestsPIDActiveTime  

TsTestsPreferencesEntry  
SEQUENCE    
  InputNumber as tsTestsPrefInputNumber  
  FloatingPoint as tsTestsPrefTransitionDuration  
  FloatingPoint as tsTestsPrefPATSectionIntervalMax  
  FloatingPoint as tsTestsPrefPMTSectionIntervalMax  
  FloatingPoint as tsTestsPrefReferredIntervalMax  
  FloatingPoint as tsTestsPrefPCRIntervalMax  
  FloatingPoint as tsTestsPrefPCRDiscontinuityMax  
  FloatingPoint as tsTestsPrefPCRInaccuracyMax  
  FloatingPoint as tsTestsPrefPTSIntervalMax  
  FloatingPoint as tsTestsPrefNITActualIntervalMax  
  FloatingPoint as tsTestsPrefNITActualIntervalMin  
  FloatingPoint as tsTestsPrefNITOtherIntervalMax  
  FloatingPoint as tsTestsPrefSIGapMin  
  FloatingPoint as tsTestsPrefNITTableIntervalMax  
  FloatingPoint as tsTestsPrefBATTableIntervalMax  
  FloatingPoint as tsTestsPrefSDTActualTableIntervalMax  
  FloatingPoint as tsTestsPrefSDTOtherTableIntervalMax  
  FloatingPoint as tsTestsPrefEITPFActualTableIntervalMax  
  FloatingPoint as tsTestsPrefEITPFOtherTableIntervalMax  
  FloatingPoint as tsTestsPrefEITSActualNearTableIntervalMax  
  FloatingPoint as tsTestsPrefEITSActualFarTableIntervalMax  
  FloatingPoint as tsTestsPrefEITSOtherNearTableIntervalMax  
  FloatingPoint as tsTestsPrefEITSOtherFarTableIntervalMax  
  FloatingPoint as tsTestsPrefTxTTableIntervalMax  
  FloatingPoint as tsTestsPrefSDTActualIntervalMax  
  FloatingPoint as tsTestsPrefSDTActualIntervalMin  
  FloatingPoint as tsTestsPrefSDTOtherIntervalMax  
  FloatingPoint as tsTestsPrefEITActualIntervalMax  
  FloatingPoint as tsTestsPrefEITActualIntervalMin  
  FloatingPoint as tsTestsPrefEITOtherIntervalMax  
  FloatingPoint as tsTestsPrefRSTIntervalMin  
  FloatingPoint as tsTestsPrefTDTIntervalMax  
  FloatingPoint as tsTestsPrefTDTIntervalMin  

TsTestsPreferencesPIDEntry  
SEQUENCE    
  InputNumber as tsTestsPrefPIDInputNumber  
  PIDPlusOne as tsTestsPrefPIDPID  
  RowStatus as tsTestsPrefPIDRowStatus  
  FloatingPoint as tsTestsPrefPIDReferredIntervalMax  

TsPcrMeasurementEntry  
SEQUENCE    
  InputNumber as tsPcrMeasurementInputNumber  
  PIDPlusOne as tsPcrMeasurementPID  
  IndexPCRMeasurement as tsPcrMeasurementNumber  
  RowStatus as tsPcrMeasurementRowStatus  
  TestState as tsPcrMeasurementState  
  Enable as tsPcrMeasurementEnable  
  Counter32 as tsPcrMeasurementCounter  
  DateAndTime as tsPcrMeasurementCounterDiscontinuity  
  TruthValue as tsPcrMeasurementCounterReset  
  DateAndTime as tsPcrMeasurementLatestError  
  ActiveTime as tsPcrMeasurementActiveTime  
  MeasurementState as tsPcrMeasurementMeasurementState  
  FloatingPoint as tsPcrMeasurementValue  

TsTransportStreamBitRateEntry  
SEQUENCE    
  InputNumber as tsTransportStreamBitRateInputNumber  
  TestState as tsTransportStreamBitRateState  
  Enable as tsTransportStreamBitRateEnable  
  Counter32 as tsTransportStreamBitRateCounter  
  DateAndTime as tsTransportStreamBitRateCounterDiscontinuity  
  TruthValue as tsTransportStreamBitRateCounterReset  
  DateAndTime as tsTransportStreamBitRateLatestError  
  ActiveTime as tsTransportStreamBitRateActiveTime  
  MeasurementState as tsTransportStreamBitRateMeasurementState  
  FloatingPoint as tsTransportStreamBitRateValue  
  DisplayString as tsTransportStreamBitRateNomenclature  

TsServiceBitRateEntry  
SEQUENCE    
  InputNumber as tsServiceBitRateInputNumber  
  ServiceId as tsServiceBitRateService  
  RowStatus as tsServiceBitRateRowStatus  
  TestState as tsServiceBitRateState  
  Enable as tsServiceBitRateEnable  
  Counter32 as tsServiceBitRateCounter  
  DateAndTime as tsServiceBitRateCounterDiscontinuity  
  TruthValue as tsServiceBitRateCounterReset  
  DateAndTime as tsServiceBitRateLatestError  
  ActiveTime as tsServiceBitRateActiveTime  
  MeasurementState as tsServiceBitRateMeasurementState  
  FloatingPoint as tsServiceBitRateValue  
  DisplayString as tsServiceBitRateNomenclature  

TsPIDBitRateEntry  
SEQUENCE    
  InputNumber as tsPIDBitRateInputNumber  
  PIDPlusOne as tsPIDBitRatePID  
  RowStatus as tsPIDBitRateRowStatus  
  TestState as tsPIDBitRateState  
  Enable as tsPIDBitRateEnable  
  Counter32 as tsPIDBitRateCounter  
  DateAndTime as tsPIDBitRateCounterDiscontinuity  
  TruthValue as tsPIDBitRateCounterReset  
  DateAndTime as tsPIDBitRateLatestError  
  ActiveTime as tsPIDBitRateActiveTime  
  MeasurementState as tsPIDBitRateMeasurementState  
  FloatingPoint as tsPIDBitRateValue  
  DisplayString as tsPIDBitRateNomenclature  

TsConsistencyEntry  
SEQUENCE    
  InputNumber as tsConsistencyInputNumber  
  IndexConsistencyTest as tsConsistencyTestNumber  
  TestState as tsConsistencyState  
  Enable as tsConsistencyEnable  
  Counter32 as tsConsistencyCounter  
  DateAndTime as tsConsistencyCounterDiscontinuity  
  TruthValue as tsConsistencyCounterReset  
  DateAndTime as tsConsistencyLatestError  
  ActiveTime as tsConsistencyActiveTime  

TsMeasurePreferencesEntry  
SEQUENCE    
  InputNumber as tsMeasurePrefInputNumber  
  FloatingPoint as tsMeasurePrefPCRDemarcationFrequency  
  FloatingPoint as tsMeasurePrefPCRFOMax  
  FloatingPoint as tsMeasurePrefPCRDRMax  
  FloatingPoint as tsMeasurePrefPCROJMax  
  FloatingPoint as tsMeasurePrefTSBitRateTau  
  Unsigned32 as tsMeasurePrefTSBitRateN  
  BitRateElement as tsMeasurePrefTSBitRateElement  
  FloatingPoint as tsMeasurePrefTSBitRateMin  
  FloatingPoint as tsMeasurePrefTSBitRateMax  
  FloatingPoint as tsMeasurePrefAllServiceBitRateTau  
  Unsigned32 as tsMeasurePrefAllServiceBitRateN  
  BitRateElement as tsMeasurePrefAllServiceBitRateElement  
  FloatingPoint as tsMeasurePrefAllPIDBitRateTau  
  Unsigned32 as tsMeasurePrefAllPIDBitRateN  
  BitRateElement as tsMeasurePrefAllPIDBitRateElement  
  TransportStreamID as tsMeasurePrefExpectedTSID  

TsMeasurePreferencesServiceEntry  
SEQUENCE    
  InputNumber as tsMeasurePrefServiceInputNumber  
  ServiceId as tsMeasurePrefServiceService  
  RowStatus as tsMeasurePrefServiceRowStatus  
  FloatingPoint as tsMeasurePrefServiceBitRateTau  
  Unsigned32 as tsMeasurePrefServiceBitRateN  
  BitRateElement as tsMeasurePrefServiceBitRateElement  
  FloatingPoint as tsMeasurePrefServiceBitRateMin  
  FloatingPoint as tsMeasurePrefServiceBitRateMax  

TsMeasurePreferencesPIDEntry  
SEQUENCE    
  InputNumber as tsMeasurePrefPIDInputNumber  
  PIDPlusOne as tsMeasurePrefPIDPID  
  RowStatus as tsMeasurePrefPIDRowStatus  
  FloatingPoint as tsMeasurePrefPIDBitRateTau  
  Unsigned32 as tsMeasurePrefPIDBitRateN  
  BitRateElement as tsMeasurePrefPIDBitRateElement  
  FloatingPoint as tsMeasurePrefPIDBitRateMin  
  FloatingPoint as tsMeasurePrefPIDBitRateMax  

TsServicePerformanceEntry  
SEQUENCE    
  InputNumber as tsServicePerformanceInputNumber  
  IndexServicePerformance as tsServicePerformanceNumber  
  TestState as tsServicePerformanceState  
  Enable as tsServicePerformanceEnable  
  Counter32 as tsServicePerformanceCounter  
  DateAndTime as tsServicePerformanceCounterDiscontinuity  
  TruthValue as tsServicePerformanceCounterReset  
  DateAndTime as tsServicePerformanceLatestError  
  ActiveTime as tsServicePerformanceActiveTime  
  MeasurementState as tsServicePerformanceMeasurementState  
  Unsigned32 as tsServicePerformanceError  
  FloatingPoint as tsServicePerformanceErrorRatio  

TsServicePerformancePreferencesEntry  
SEQUENCE    
  InputNumber as tsSPPrefInputNumber  
  IndexServicePerformance as tsSPPrefNumber  
  FloatingPoint as tsSPPrefDeltaT  
  FloatingPoint as tsSPPrefEvaluationTime  
  FloatingPoint as tsSPPrefThreshold  

SysAvailabilityEntry  
SEQUENCE    
  InputNumber as sysAvailabilityInputNumber  
  TestState as sysAvailabilityTestState  
  Enable as sysAvailabilityEnable  
  Counter32 as sysAvailabilityCounter  
  DateAndTime as sysAvailabilityCounterDiscontinuity  
  TruthValue as sysAvailabilityCounterReset  
  DateAndTime as sysAvailabilityLatestError  
  ActiveTime as sysAvailabilityActiveTime  
  MeasurementState as sysAvailabilityMeasurementState  
  Unsigned32 as sysAvailabilityUnavailableTime  
  FloatingPoint as sysAvailabilityRatio  
  TruthValue as sysAvailabilityInSETI  

LinkAvailabilityEntry  
SEQUENCE    
  InputNumber as linkAvailabilityInputNumber  
  TestState as linkAvailabilityTestState  
  Enable as linkAvailabilityEnable  
  Counter32 as linkAvailabilityCounter  
  DateAndTime as linkAvailabilityCounterDiscontinuity  
  TruthValue as linkAvailabilityCounterReset  
  DateAndTime as linkAvailabilityLatestError  
  ActiveTime as linkAvailabilityActiveTime  
  MeasurementState as linkAvailabilityMeasurementState  
  Unsigned32 as linkAvailabilityUnavailableTime  
  FloatingPoint as linkAvailabilityRatio  
  TruthValue as linkAvailabilityInSUTI  

BerRSinServiceEntry  
SEQUENCE    
  InputNumber as berRSinServiceInputNumber  
  TestState as berRSinServiceTestState  
  Enable as berRSinServiceEnable  
  Counter32 as berRSinServiceCounter  
  DateAndTime as berRSinServiceCounterDiscontinuity  
  TruthValue as berRSinServiceCounterReset  
  DateAndTime as berRSinServiceLatestError  
  ActiveTime as berRSinServiceActiveTime  
  MeasurementState as berRSinServiceMeasurementState  
  FloatingPoint as berRSinServiceValue  

RfIFsignalPowerEntry  
SEQUENCE    
  InputNumber as rfIFsignalPowerInputNumber  
  TestState as rfIFsignalPowerTestState  
  Enable as rfIFsignalPowerEnable  
  Counter32 as rfIFsignalPowerCounter  
  DateAndTime as rfIFsignalPowerCounterDiscontinuity  
  TruthValue as rfIFsignalPowerCounterReset  
  DateAndTime as rfIFsignalPowerLatestError  
  ActiveTime as rfIFsignalPowerActiveTime  
  MeasurementState as rfIFsignalPowerMeasurementState  
  FloatingPoint as rfIFsignalPowerValue  

NoisePowerEntry  
SEQUENCE    
  InputNumber as noisePowerInputNumber  
  TestState as noisePowerTestState  
  Enable as noisePowerEnable  
  Counter32 as noisePowerCounter  
  DateAndTime as noisePowerCounterDiscontinuity  
  TruthValue as noisePowerCounterReset  
  DateAndTime as noisePowerLatestError  
  ActiveTime as noisePowerActiveTime  
  MeasurementState as noisePowerMeasurementState  
  FloatingPoint as noisePowerValue  

MerCSEntry  
SEQUENCE    
  InputNumber as merCSInputNumber  
  TestState as merCSTestState  
  Enable as merCSEnable  
  Counter32 as merCSCounter  
  DateAndTime as merCSCounterDiscontinuity  
  TruthValue as merCSCounterReset  
  DateAndTime as merCSLatestError  
  ActiveTime as merCSActiveTime  
  MeasurementState as merCSMeasurementState  
  FloatingPoint as merCSValue  

SteMeanCSEntry  
SEQUENCE    
  InputNumber as steMeanCSInputNumber  
  TestState as steMeanCSTestState  
  Enable as steMeanCSEnable  
  Counter32 as steMeanCSCounter  
  DateAndTime as steMeanCSCounterDiscontinuity  
  TruthValue as steMeanCSCounterReset  
  DateAndTime as steMeanCSLatestError  
  ActiveTime as steMeanCSActiveTime  
  MeasurementState as steMeanCSMeasurementState  
  FloatingPoint as steMeanCSValue  

SteDeviationCSEntry  
SEQUENCE    
  InputNumber as steDeviationCSInputNumber  
  TestState as steDeviationCSTestState  
  Enable as steDeviationCSEnable  
  Counter32 as steDeviationCSCounter  
  DateAndTime as steDeviationCSCounterDiscontinuity  
  TruthValue as steDeviationCSCounterReset  
  DateAndTime as steDeviationCSLatestError  
  ActiveTime as steDeviationCSActiveTime  
  MeasurementState as steDeviationCSMeasurementState  
  FloatingPoint as steDeviationCSValue  

CsCSEntry  
SEQUENCE    
  InputNumber as csCSInputNumber  
  TestState as csCSTestState  
  Enable as csCSEnable  
  Counter32 as csCSCounter  
  DateAndTime as csCSCounterDiscontinuity  
  TruthValue as csCSCounterReset  
  DateAndTime as csCSLatestError  
  ActiveTime as csCSActiveTime  
  MeasurementState as csCSMeasurementState  
  FloatingPoint as csCSValue  

AiCSEntry  
SEQUENCE    
  InputNumber as aiCSInputNumber  
  TestState as aiCSTestState  
  Enable as aiCSEnable  
  Counter32 as aiCSCounter  
  DateAndTime as aiCSCounterDiscontinuity  
  TruthValue as aiCSCounterReset  
  DateAndTime as aiCSLatestError  
  ActiveTime as aiCSActiveTime  
  MeasurementState as aiCSMeasurementState  
  FloatingPoint as aiCSValue  

QeCSEntry  
SEQUENCE    
  InputNumber as qeCSInputNumber  
  TestState as qeCSTestState  
  Enable as qeCSEnable  
  Counter32 as qeCSCounter  
  DateAndTime as qeCSCounterDiscontinuity  
  TruthValue as qeCSCounterReset  
  DateAndTime as qeCSLatestError  
  ActiveTime as qeCSActiveTime  
  MeasurementState as qeCSMeasurementState  
  FloatingPoint as qeCSValue  

RteCSEntry  
SEQUENCE    
  InputNumber as rteCSInputNumber  
  TestState as rteCSTestState  
  Enable as rteCSEnable  
  Counter32 as rteCSCounter  
  DateAndTime as rteCSCounterDiscontinuity  
  TruthValue as rteCSCounterReset  
  DateAndTime as rteCSLatestError  
  ActiveTime as rteCSActiveTime  
  MeasurementState as rteCSMeasurementState  
  FloatingPoint as rteCSValue  

CiCSEntry  
SEQUENCE    
  InputNumber as ciCSInputNumber  
  TestState as ciCSTestState  
  Enable as ciCSEnable  
  Counter32 as ciCSCounter  
  DateAndTime as ciCSCounterDiscontinuity  
  TruthValue as ciCSCounterReset  
  DateAndTime as ciCSLatestError  
  ActiveTime as ciCSActiveTime  
  MeasurementState as ciCSMeasurementState  
  FloatingPoint as ciCSValue  

PjCSEntry  
SEQUENCE    
  InputNumber as pjCSInputNumber  
  TestState as pjCSTestState  
  Enable as pjCSEnable  
  Counter32 as pjCSCounter  
  DateAndTime as pjCSCounterDiscontinuity  
  TruthValue as pjCSCounterReset  
  DateAndTime as pjCSLatestError  
  ActiveTime as pjCSActiveTime  
  MeasurementState as pjCSMeasurementState  
  FloatingPoint as pjCSValue  

SnrCSEntry  
SEQUENCE    
  InputNumber as snrCSInputNumber  
  TestState as snrCSTestState  
  Enable as snrCSEnable  
  Counter32 as snrCSCounter  
  DateAndTime as snrCSCounterDiscontinuity  
  TruthValue as snrCSCounterReset  
  DateAndTime as snrCSLatestError  
  ActiveTime as snrCSActiveTime  
  MeasurementState as snrCSMeasurementState  
  FloatingPoint as snrCSValue  

CableSatPreferencesEntry  
SEQUENCE    
  InputNumber as cableSatPrefInputNumber  
  FloatingPoint as cableSatPrefCentreFrequency  
  Modulation as cableSatPrefModulation  
  UATMode as cableSatPrefSysAvailUATMode  
  Unsigned32 as cableSatPrefSysAvailN  
  FloatingPoint as cableSatPrefSysAvailT  
  Unsigned32 as cableSatPrefSysAvailM  
  FloatingPoint as cableSatPrefSysAvailTI  
  FloatingPoint as cableSatPrefSysAvailEBPerCent  
  FloatingPoint as cableSatPrefSysAvailTotalTime  
  UATMode as cableSatPrefLinkAvailUATMode  
  Unsigned32 as cableSatPrefLinkAvailN  
  FloatingPoint as cableSatPrefLinkAvailT  
  Unsigned32 as cableSatPrefLinkAvailM  
  FloatingPoint as cableSatPrefLinkAvailTI  
  FloatingPoint as cableSatPrefLinkAvailUPPerCent  
  FloatingPoint as cableSatPrefLinkAvailTotalTime  
  FloatingPoint as cableSatPrefBERMax  
  FloatingPoint as cableSatPrefSignalPowerMin  
  FloatingPoint as cableSatPrefSignalPowerMax  
  FloatingPoint as cableSatPrefNoisePowerMax  
  FloatingPoint as cableSatPrefMerCSMin  
  FloatingPoint as cableSatPrefSteMeanCSMax  
  FloatingPoint as cableSatPrefSteDeviationCSMax  
  FloatingPoint as cableSatPrefCsCSMin  
  FloatingPoint as cableSatPrefAiCSMax  
  FloatingPoint as cableSatPrefQeCSMax  
  FloatingPoint as cableSatPrefRteCSMax  
  FloatingPoint as cableSatPrefCiCSMin  
  FloatingPoint as cableSatPrefPjCSMax  
  FloatingPoint as cableSatPrefSnrCSMin  

NoiseMarginEntry  
SEQUENCE    
  InputNumber as noiseMarginInputNumber  
  TestState as noiseMarginTestState  
  Enable as noiseMarginEnable  
  Counter32 as noiseMarginCounter  
  DateAndTime as noiseMarginCounterDiscontinuity  
  TruthValue as noiseMarginCounterReset  
  DateAndTime as noiseMarginLatestError  
  ActiveTime as noiseMarginActiveTime  
  MeasurementState as noiseMarginMeasurementState  
  FloatingPoint as noiseMarginValue  

EstNoiseMarginEntry  
SEQUENCE    
  InputNumber as estNoiseMarginInputNumber  
  TestState as estNoiseMarginTestState  
  Enable as estNoiseMarginEnable  
  Counter32 as estNoiseMarginCounter  
  DateAndTime as estNoiseMarginCounterDiscontinuity  
  TruthValue as estNoiseMarginCounterReset  
  DateAndTime as estNoiseMarginLatestError  
  ActiveTime as estNoiseMarginActiveTime  
  MeasurementState as estNoiseMarginMeasurementState  
  FloatingPoint as estNoiseMarginValue  

SignQualMarTEntry  
SEQUENCE    
  InputNumber as signQualMarTInputNumber  
  TestState as signQualMarTTestState  
  Enable as signQualMarTEnable  
  Counter32 as signQualMarTCounter  
  DateAndTime as signQualMarTCounterDiscontinuity  
  TruthValue as signQualMarTCounterReset  
  DateAndTime as signQualMarTLatestError  
  ActiveTime as signQualMarTActiveTime  

ENDCEntry  
SEQUENCE    
  InputNumber as eNDCInputNumber  
  TestState as eNDCTestState  
  Enable as eNDCEnable  
  Counter32 as eNDCCounter  
  DateAndTime as eNDCCounterDiscontinuity  
  TruthValue as eNDCCounterReset  
  DateAndTime as eNDCLatestError  
  ActiveTime as eNDCActiveTime  
  MeasurementState as eNDCMeasurementState  
  FloatingPoint as eNDCValue  

OutBandEmissEntry  
SEQUENCE    
  InputNumber as outBandEmissInputNumber  
  TestState as outBandEmissTestState  
  Enable as outBandEmissEnable  
  Counter32 as outBandEmissCounter  
  DateAndTime as outBandEmissCounterDiscontinuity  
  TruthValue as outBandEmissCounterReset  
  DateAndTime as outBandEmissLatestError  
  ActiveTime as outBandEmissActiveTime  

CablePreferencesEntry  
SEQUENCE    
  InputNumber as cablePrefInputNumber  
  FloatingPoint as cablePrefNoiseMarginMin  
  FloatingPoint as cablePrefEstNoiseMarginMin  
  FloatingPoint as cablePrefSignQualBoxSize  
  Integer32 as cablePrefSignQualPercentMax  
  FloatingPoint as cablePrefENDBER  
  TruthValue as cablePrefENDCtoNSpecified  
  FloatingPoint as cablePrefENDIdeal  
  FloatingPoint as cablePrefENDMax  

BerViterbiSEntry  
SEQUENCE    
  InputNumber as berViterbiSInputNumber  
  TestState as berViterbiSTestState  
  Enable as berViterbiSEnable  
  Counter32 as berViterbiSCounter  
  DateAndTime as berViterbiSCounterDiscontinuity  
  TruthValue as berViterbiSCounterReset  
  DateAndTime as berViterbiSLatestError  
  ActiveTime as berViterbiSActiveTime  
  MeasurementState as berViterbiSMeasurementState  
  FloatingPoint as berViterbiSIValue  
  FloatingPoint as berViterbiSQValue  
  BERMeasurementMethod as berViterbiSMeasurementMethod  

IfSpectrumEntry  
SEQUENCE    
  InputNumber as ifSpectrumInputNumber  
  TestState as ifSpectrumTestState  
  Enable as ifSpectrumEnable  
  Counter32 as ifSpectrumCounter  
  DateAndTime as ifSpectrumCounterDiscontinuity  
  TruthValue as ifSpectrumCounterReset  
  DateAndTime as ifSpectrumLatestError  
  ActiveTime as ifSpectrumActiveTime  

SatellitePreferencesEntry  
SEQUENCE    
  InputNumber as satellitePrefInputNumber  
  FloatingPoint as satellitePrefBERMax  

RfAccuracyEntry  
SEQUENCE    
  InputNumber as rfAccuracyInputNumber  
  TestState as rfAccuracyTestState  
  Enable as rfAccuracyEnable  
  Counter32 as rfAccuracyCounter  
  DateAndTime as rfAccuracyCounterDiscontinuity  
  TruthValue as rfAccuracyCounterReset  
  DateAndTime as rfAccuracyLatestError  
  ActiveTime as rfAccuracyActiveTime  
  MeasurementState as rfAccuracyMeasurementState  
  FloatingPoint as rfAccuracyValue  

RfChannelWidthEntry  
SEQUENCE    
  InputNumber as rfChannelWidthInputNumber  
  TestState as rfChannelWidthTestState  
  Enable as rfChannelWidthEnable  
  Counter32 as rfChannelWidthCounter  
  DateAndTime as rfChannelWidthCounterDiscontinuity  
  TruthValue as rfChannelWidthCounterReset  
  DateAndTime as rfChannelWidthLatestError  
  ActiveTime as rfChannelWidthActiveTime  
  MeasurementState as rfChannelWidthMeasurementState  
  FloatingPoint as rfChannelWidthValue  

SymbolLengthEntry  
SEQUENCE    
  InputNumber as symbolLengthInputNumber  
  TestState as symbolLengthTestState  
  Enable as symbolLengthEnable  
  Counter32 as symbolLengthCounter  
  DateAndTime as symbolLengthCounterDiscontinuity  
  TruthValue as symbolLengthCounterReset  
  DateAndTime as symbolLengthLatestError  
  ActiveTime as symbolLengthActiveTime  
  MeasurementState as symbolLengthMeasurementState  
  FloatingPoint as symbolLengthValue  

RfIfPowerEntry  
SEQUENCE    
  InputNumber as rfIfPowerInputNumber  
  TestState as rfIfPowerTestState  
  Enable as rfIfPowerEnable  
  Counter32 as rfIfPowerCounter  
  DateAndTime as rfIfPowerCounterDiscontinuity  
  TruthValue as rfIfPowerCounterReset  
  DateAndTime as rfIfPowerLatestError  
  ActiveTime as rfIfPowerActiveTime  
  MeasurementState as rfIfPowerMeasurementState  
  FloatingPoint as rfIfPowerValue  

RfIfSpectrumEntry  
SEQUENCE    
  InputNumber as rfIfSpectrumInputNumber  
  TestState as rfIfSpectrumTestState  
  Enable as rfIfSpectrumEnable  
  Counter32 as rfIfSpectrumCounter  
  DateAndTime as rfIfSpectrumCounterDiscontinuity  
  TruthValue as rfIfSpectrumCounterReset  
  DateAndTime as rfIfSpectrumLatestError  
  ActiveTime as rfIfSpectrumActiveTime  

ENDTEntry  
SEQUENCE    
  InputNumber as eNDTInputNumber  
  TestState as eNDTTestState  
  Enable as eNDTEnable  
  Counter32 as eNDTCounter  
  DateAndTime as eNDTCounterDiscontinuity  
  TruthValue as eNDTCounterReset  
  DateAndTime as eNDTLatestError  
  ActiveTime as eNDTActiveTime  
  MeasurementState as eNDTMeasurementState  
  FloatingPoint as eNDTValue  

ENFTEntry  
SEQUENCE    
  InputNumber as eNFTInputNumber  
  TestState as eNFTTestState  
  Enable as eNFTEnable  
  Counter32 as eNFTCounter  
  DateAndTime as eNFTCounterDiscontinuity  
  TruthValue as eNFTCounterReset  
  DateAndTime as eNFTLatestError  
  ActiveTime as eNFTActiveTime  
  MeasurementState as eNFTMeasurementState  
  FloatingPoint as eNFTValue  

ENDTLPEntry  
SEQUENCE    
  InputNumber as eNDTLPInputNumber  
  TestState as eNDTLPTestState  
  Enable as eNDTLPEnable  
  Counter32 as eNDTLPCounter  
  DateAndTime as eNDTLPCounterDiscontinuity  
  TruthValue as eNDTLPCounterReset  
  DateAndTime as eNDTLPLatestError  
  ActiveTime as eNDTLPActiveTime  
  MeasurementState as eNDTLPMeasurementState  
  FloatingPoint as eNDTLPValue  

ENFTLPEntry  
SEQUENCE    
  InputNumber as eNFTLPInputNumber  
  TestState as eNFTLPTestState  
  Enable as eNFTLPEnable  
  Counter32 as eNFTLPCounter  
  DateAndTime as eNFTLPCounterDiscontinuity  
  TruthValue as eNFTLPCounterReset  
  DateAndTime as eNFTLPLatestError  
  ActiveTime as eNFTLPActiveTime  
  MeasurementState as eNFTLPMeasurementState  
  FloatingPoint as eNFTLPValue  

LinearityEntry  
SEQUENCE    
  InputNumber as linearityInputNumber  
  TestState as linearityTestState  
  Enable as linearityEnable  
  Counter32 as linearityCounter  
  DateAndTime as linearityCounterDiscontinuity  
  TruthValue as linearityCounterReset  
  DateAndTime as linearityLatestError  
  ActiveTime as linearityActiveTime  
  MeasurementState as linearityMeasurementState  
  FloatingPoint as linearityValue  

BerViterbiTEntry  
SEQUENCE    
  InputNumber as berViterbiTInputNumber  
  TestState as berViterbiTTestState  
  Enable as berViterbiTEnable  
  Counter32 as berViterbiTCounter  
  DateAndTime as berViterbiTCounterDiscontinuity  
  TruthValue as berViterbiTCounterReset  
  DateAndTime as berViterbiTLatestError  
  ActiveTime as berViterbiTActiveTime  
  MeasurementState as berViterbiTMeasurementState  
  FloatingPoint as berViterbiTValue  

BerViterbiTLPEntry  
SEQUENCE    
  InputNumber as berViterbiTLPInputNumber  
  TestState as berViterbiTLPTestState  
  Enable as berViterbiTLPEnable  
  Counter32 as berViterbiTLPCounter  
  DateAndTime as berViterbiTLPCounterDiscontinuity  
  TruthValue as berViterbiTLPCounterReset  
  DateAndTime as berViterbiTLPLatestError  
  ActiveTime as berViterbiTLPActiveTime  
  MeasurementState as berViterbiTLPMeasurementState  
  FloatingPoint as berViterbiTLPValue  

BerRSEntry  
SEQUENCE    
  InputNumber as berRSInputNumber  
  TestState as berRSTestState  
  Enable as berRSEnable  
  Counter32 as berRSCounter  
  DateAndTime as berRSCounterDiscontinuity  
  TruthValue as berRSCounterReset  
  DateAndTime as berRSLatestError  
  ActiveTime as berRSActiveTime  
  MeasurementState as berRSMeasurementState  
  FloatingPoint as berRSValue  

BerRSLPEntry  
SEQUENCE    
  InputNumber as berRSLPInputNumber  
  TestState as berRSLPTestState  
  Enable as berRSLPEnable  
  Counter32 as berRSLPCounter  
  DateAndTime as berRSLPCounterDiscontinuity  
  TruthValue as berRSLPCounterReset  
  DateAndTime as berRSLPLatestError  
  ActiveTime as berRSLPActiveTime  
  MeasurementState as berRSLPMeasurementState  
  FloatingPoint as berRSLPValue  

MerTEntry  
SEQUENCE    
  InputNumber as merTInputNumber  
  TestState as merTTestState  
  Enable as merTEnable  
  Counter32 as merTCounter  
  DateAndTime as merTCounterDiscontinuity  
  TruthValue as merTCounterReset  
  DateAndTime as merTLatestError  
  ActiveTime as merTActiveTime  
  MeasurementState as merTMeasurementState  
  FloatingPoint as merTValue  

SteMeanTEntry  
SEQUENCE    
  InputNumber as steMeanTInputNumber  
  TestState as steMeanTTestState  
  Enable as steMeanTEnable  
  Counter32 as steMeanTCounter  
  DateAndTime as steMeanTCounterDiscontinuity  
  TruthValue as steMeanTCounterReset  
  DateAndTime as steMeanTLatestError  
  ActiveTime as steMeanTActiveTime  
  MeasurementState as steMeanTMeasurementState  
  FloatingPoint as steMeanTValue  

SteDeviationTEntry  
SEQUENCE    
  InputNumber as steDeviationTInputNumber  
  TestState as steDeviationTTestState  
  Enable as steDeviationTEnable  
  Counter32 as steDeviationTCounter  
  DateAndTime as steDeviationTCounterDiscontinuity  
  TruthValue as steDeviationTCounterReset  
  DateAndTime as steDeviationTLatestError  
  ActiveTime as steDeviationTActiveTime  
  MeasurementState as steDeviationTMeasurementState  
  FloatingPoint as steDeviationTValue  

CsTEntry  
SEQUENCE    
  InputNumber as csTInputNumber  
  TestState as csTTestState  
  Enable as csTEnable  
  Counter32 as csTCounter  
  DateAndTime as csTCounterDiscontinuity  
  TruthValue as csTCounterReset  
  DateAndTime as csTLatestError  
  ActiveTime as csTActiveTime  
  MeasurementState as csTMeasurementState  
  FloatingPoint as csTValue  

AiTEntry  
SEQUENCE    
  InputNumber as aiTInputNumber  
  TestState as aiTTestState  
  Enable as aiTEnable  
  Counter32 as aiTCounter  
  DateAndTime as aiTCounterDiscontinuity  
  TruthValue as aiTCounterReset  
  DateAndTime as aiTLatestError  
  ActiveTime as aiTActiveTime  
  MeasurementState as aiTMeasurementState  
  FloatingPoint as aiTValue  

QeTEntry  
SEQUENCE    
  InputNumber as qeTInputNumber  
  TestState as qeTTestState  
  Enable as qeTEnable  
  Counter32 as qeTCounter  
  DateAndTime as qeTCounterDiscontinuity  
  TruthValue as qeTCounterReset  
  DateAndTime as qeTLatestError  
  ActiveTime as qeTActiveTime  
  MeasurementState as qeTMeasurementState  
  FloatingPoint as qeTValue  

PjTEntry  
SEQUENCE    
  InputNumber as pjTInputNumber  
  TestState as pjTTestState  
  Enable as pjTEnable  
  Counter32 as pjTCounter  
  DateAndTime as pjTCounterDiscontinuity  
  TruthValue as pjTCounterReset  
  DateAndTime as pjTLatestError  
  ActiveTime as pjTActiveTime  
  MeasurementState as pjTMeasurementState  
  FloatingPoint as pjTValue  

MipSyntaxEntry  
SEQUENCE    
  InputNumber as mipSyntaxInputNumber  
  IndexMIPSyntaxTest as mipSyntaxTestNumber  
  TestState as mipSyntaxState  
  Enable as mipSyntaxEnable  
  Counter32 as mipSyntaxCounter  
  DateAndTime as mipSyntaxCounterDiscontinuity  
  TruthValue as mipSyntaxCounterReset  
  DateAndTime as mipSyntaxLatestError  
  ActiveTime as mipSyntaxActiveTime  

SepEtiEntry  
SEQUENCE    
  InputNumber as sepEtiInputNumber  
  TestState as sepEtiTestState  
  Enable as sepEtiEnable  
  Counter32 as sepEtiCounter  
  DateAndTime as sepEtiCounterDiscontinuity  
  TruthValue as sepEtiCounterReset  
  DateAndTime as sepEtiLatestError  
  ActiveTime as sepEtiActiveTime  
  MeasurementState as sepEtiMeasurementState  
  FloatingPoint as sepEtiValue  

SepSetiEntry  
SEQUENCE    
  InputNumber as sepSetiInputNumber  
  TestState as sepSetiTestState  
  Enable as sepSetiEnable  
  Counter32 as sepSetiCounter  
  DateAndTime as sepSetiCounterDiscontinuity  
  TruthValue as sepSetiCounterReset  
  DateAndTime as sepSetiLatestError  
  ActiveTime as sepSetiActiveTime  
  MeasurementState as sepSetiMeasurementState  
  FloatingPoint as sepSetiValue  

TerrestrialPreferencesEntry  
SEQUENCE    
  InputNumber as terrestrialPrefInputNumber  
  FloatingPoint as terrestrialPrefCentreFrequency  
  FloatingPoint as terrestrialPrefBandwidth  
  Modulation as terrestrialPrefModulation  
  TerrestrialTransmissionMode as terrestrialPrefTransmissionMode  
  GuardInterval as terrestrialPrefGuardInterval  
  Hierarchy as terrestrialPrefHierarchical  
  FloatingPoint as terrestrialPrefCentreFreqExpected  
  FloatingPoint as terrestrialPrefCentreFreqLimit  
  FloatingPoint as terrestrialPrefChannelWidthLimit  
  FloatingPoint as terrestrialPrefSymbolLengthLimit  
  FloatingPoint as terrestrialPrefPowerMin  
  FloatingPoint as terrestrialPrefPowerMax  
  FloatingPoint as terrestrialPrefENDBER  
  FloatingPoint as terrestrialPrefENDIdeal  
  FloatingPoint as terrestrialPrefENDMax  
  FloatingPoint as terrestrialPrefENFIdeal  
  FloatingPoint as terrestrialPrefENFMax  
  FloatingPoint as terrestrialPrefENDLPIdeal  
  FloatingPoint as terrestrialPrefENDLPMax  
  FloatingPoint as terrestrialPrefENFLPIdeal  
  FloatingPoint as terrestrialPrefENFLPMax  
  FloatingPoint as terrestrialPrefLinearityMin  
  FloatingPoint as terrestrialPrefBERViterbiMax  
  FloatingPoint as terrestrialPrefBERViterbiLPMax  
  FloatingPoint as terrestrialPrefBERRSMax  
  FloatingPoint as terrestrialPrefBERRSLPMax  
  FloatingPoint as terrestrialPrefMerTMin  
  FloatingPoint as terrestrialPrefSteMeanMax  
  FloatingPoint as terrestrialPrefSteDeviationMax  
  FloatingPoint as terrestrialPrefCsMin  
  FloatingPoint as terrestrialPrefAiMax  
  FloatingPoint as terrestrialPrefQeMax  
  FloatingPoint as terrestrialPrefPjMax  
  FloatingPoint as terrestrialPrefMIPTimingLimit  
  FloatingPoint as terrestrialPrefMIPDeviationMax  
  UATMode as terrestrialPrefSEPUATMode  
  Unsigned32 as terrestrialPrefSEPN  
  FloatingPoint as terrestrialPrefSEPT  
  Unsigned32 as terrestrialPrefSEPM  
  FloatingPoint as terrestrialPrefSEPTI  
  FloatingPoint as terrestrialPrefSEPEBPerCent  
  FloatingPoint as terrestrialPrefSEPMeasurementInterval