EFDATA-SPECTRACAST-DR5000-MIB
File:
EFDATA-SPECTRACAST-DR5000-MIB.mib (15495 bytes)
Imported modules
Imported symbols
Defined Objects
| efdata |
1.3.6.1.4.1.6247 |
| OBJECT IDENTIFIER |
|
|
|
| dr5000 |
1.3.6.1.4.1.6247.3.2 |
| OBJECT IDENTIFIER |
|
|
|
| general |
1.3.6.1.4.1.6247.3.2.1 |
| OBJECT IDENTIFIER |
|
|
|
| polarity |
1.3.6.1.4.1.6247.3.2.2.4 |
| Polarity may take values: Disabled(0), Vertical(14) or Horizontal(18) (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disabled(0), vertical(14), horizontal(18) |
|
| frequencyRange |
1.3.6.1.4.1.6247.3.2.2.5 |
| Frequency range may take values: Low(0) or High(1) (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
low(0), high(1) |
|
| pidTable |
1.3.6.1.4.1.6247.3.2.3.2 |
| List of PID entries. The number of entries is given by PIDs-number value. |
| OBJECT-TYPE |
|
|
|
| |
SEQUENCE OF |
|
|
| |
|
PIDentry |
|
| pidEntry |
1.3.6.1.4.1.6247.3.2.3.2.1 |
| PID entry containing objects for the particular PID. |
| OBJECT-TYPE |
|
|
|
| |
PIDentry |
|
|
| pidindex |
1.3.6.1.4.1.6247.3.2.3.2.1.1 |
| Unique ID for each PID, ranges between 1 and PIDs-number (read-only). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| ccuConnectionMode |
1.3.6.1.4.1.6247.3.2.4.1 |
| CCU connection mode, may take values: Manual(0), Duplex(1) or Simplex(2) (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
manual(0), duplex(1), simplex(2) |
|
| connectionMode |
1.3.6.1.4.1.6247.3.2.5.1 |
| Connection Mode, may take values: Manual(0) or Automatic(1) (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
manual(0), automatic(1) |
|
| dialTone |
1.3.6.1.4.1.6247.3.2.5.5 |
| Dialing mode, may take values: Tone(0)) or Pulse(1) (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
tone(0), pulse(1) |
|
| speed |
1.3.6.1.4.1.6247.3.2.5.7 |
| Modem connection speed, may take values: 9600, 19200, 38400, 57600 or 115200 (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| idleTimeOut |
1.3.6.1.4.1.6247.3.2.5.8 |
| Dial on demand time out in minutes. Set to 0 in order to disable dial on demand (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| authentication |
1.3.6.1.4.1.6247.3.2.5.9 |
| Authentication mode, may take values: PAP or CHAP (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
pap(0), chap(1) |
|
| status |
1.3.6.1.4.1.6247.3.2.6 |
| OBJECT IDENTIFIER |
|
|
|
| ccu-connection-status |
1.3.6.1.4.1.6247.3.2.6.9 |
| CCU connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2), Waiting for Dialup(3), or Waiting for RF Lock(4) (read only). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disconnected(0), connected(1), tryingtoconnect(2), waitingfordialup(3), waitingforrflock(4) |
|
| dialup-connection-status |
1.3.6.1.4.1.6247.3.2.6.10 |
| Dialup connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2) or Idle(10) (read only). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disconnected(0), connected(1), tryingtoconnect(2), idle(10) |
|
| maintenance |
1.3.6.1.4.1.6247.3.2.8 |
| OBJECT IDENTIFIER |
|
|
|
| driverRestart |
1.3.6.1.4.1.6247.3.2.8.1 |
| Set to True in order to restart the Driver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
false(0), true(1) |
|
| ccuconnect |
1.3.6.1.4.1.6247.3.2.8.4 |
| Set to True in order to connect to the CCU. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
false(0), true(1) |
|
| ccudisconnect |
1.3.6.1.4.1.6247.3.2.8.5 |
| Set to True in order to disconnect from the CCU. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
false(0), true(1) |
|
| upgrade |
1.3.6.1.4.1.6247.3.2.8.6 |
| Set to the upgrade file name, and upgrade the system. After upgrade finishes the system reboots automatically (write only). |
| OBJECT-TYPE |
|
|
|
| |
DisplayString |
|
|
| enableTraps |
1.3.6.1.4.1.6247.3.2.9.1 |
| Set to True in order to start getting traps. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| trapList |
1.3.6.1.4.1.6247.3.2.9.4 |
| OBJECT IDENTIFIER |
|
|
|
| multicastTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.1.1 |
| Use multicast daemon status trap. A trap message is sent when multicast daemon goes down (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| demodulator |
1.3.6.1.4.1.6247.3.2.9.4.2 |
| OBJECT IDENTIFIER |
|
|
|
| demodulatorTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.2.1 |
| Use demodulator status trap. A trap message is sent when the demodulator loses data lock (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| ccuTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.3.1 |
| Use CCU connection status trap. A trap message is sent when CCU status changes from Connected to any other one (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| dialup |
1.3.6.1.4.1.6247.3.2.9.4.4 |
| OBJECT IDENTIFIER |
|
|
|
| dialupTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.4.1 |
| Use dialup connection status trap. A trap message is sent when dialup status changes from Connected to any other one except Idle (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| berLevel |
1.3.6.1.4.1.6247.3.2.9.4.5 |
| OBJECT IDENTIFIER |
|
|
|
| berTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.5.1 |
| Use BER level trap. A trap message is sent when BER value is greater then BER trap threshold (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| freqOffset |
1.3.6.1.4.1.6247.3.2.9.4.6 |
| OBJECT IDENTIFIER |
|
|
|
| freqOffsetTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.6.1 |
| Use frequency offset trap. A trap message is sent when absolute frequency offset is greater then frequency offset trap threshold (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
| agcLevel |
1.3.6.1.4.1.6247.3.2.9.4.7 |
| OBJECT IDENTIFIER |
|
|
|
| agcTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.7.1 |
| Use AGC level trap. A trap message is sent when gain value is greater then AGC trap threshold (read-write). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disable(0), enable(1) |
|
Defined Objects
| FLAG |
|
| INTEGER |
on(1), off(2) |
|
|
| PIDentry |
|
| SEQUENCE |
|
|
|
| |
INTEGER as pidindex |
|
|
| |
INTEGER as pidvalue |
|
|