| SNMPv2-SMI | FLARION-MIB |
| MODULE-IDENTITY | OBJECT-TYPE | NOTIFICATION-TYPE |
| flarion | rrCommonMib | AlarmSeverity |
| MoType | AddtlInfo |
| rrTrapVars | 1.3.6.1.4.1.8603.1.1.1 | ||
| OBJECT IDENTIFIER | |||
| rrTimeStamp | 1.3.6.1.4.1.8603.1.1.1.1 | ||
| The time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)). | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| rrSeqNum | 1.3.6.1.4.1.8603.1.1.1.2 | ||
| The event sequence number. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| rrSeverity | 1.3.6.1.4.1.8603.1.1.1.3 | ||
| The event severity. | |||
| OBJECT-TYPE | |||
| AlarmSeverity | |||
| rrMoType | 1.3.6.1.4.1.8603.1.1.1.4 | ||
| Type managed object associated with this trap. | |||
| OBJECT-TYPE | |||
| MoType | |||
| rrMoId | 1.3.6.1.4.1.8603.1.1.1.5 | ||
| The instance of the managed object logical identifier. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..65535 | ||
| rrAddtlInfo | 1.3.6.1.4.1.8603.1.1.1.6 | ||
| Event description. | |||
| OBJECT-TYPE | |||
| AddtlInfo | |||
| rrTraps | 1.3.6.1.4.1.8603.1.1.2 | ||
| OBJECT IDENTIFIER | |||
| rrTrapSpecific | 1.3.6.1.4.1.8603.1.1.2.0 | ||
| OBJECT IDENTIFIER | |||
| alarmTrap | 1.3.6.1.4.1.8603.1.1.2.0.1 | ||
| Alarm notification. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bootStatusUp | 1.3.6.1.4.1.8603.1.1.2.0.2 | ||
| The system is up and running. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bootStatusDown | 1.3.6.1.4.1.8603.1.1.2.0.3 | ||
| The system has failed to boot or the system is shutting down. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| mcuOperStatus | 1.3.6.1.4.1.8603.1.1.2.0.120 | ||
| MCU operational status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| mcuFaultLedStatus | 1.3.6.1.4.1.8603.1.1.2.0.121 | ||
| MCU fault LED status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| mcuTempStatus | 1.3.6.1.4.1.8603.1.1.2.0.122 | ||
| MCU temperature status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| mcuVoltageStatus | 1.3.6.1.4.1.8603.1.1.2.0.123 | ||
| MCU voltage status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| mlpppStatus | 1.3.6.1.4.1.8603.1.1.2.0.160 | ||
| Multilink PPP status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bbuOperStatus | 1.3.6.1.4.1.8603.1.1.2.0.200 | ||
| BBU operational status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bbuFaultLedStatus | 1.3.6.1.4.1.8603.1.1.2.0.201 | ||
| BBU fault LED status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bbuTempStatus | 1.3.6.1.4.1.8603.1.1.2.0.202 | ||
| BBU temperature status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bbuVoltageStatus | 1.3.6.1.4.1.8603.1.1.2.0.203 | ||
| BBU voltage status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| bbuDspStatus | 1.3.6.1.4.1.8603.1.1.2.0.204 | ||
| BBU DSP status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| alarmInputStatus | 1.3.6.1.4.1.8603.1.1.2.0.280 | ||
| Alarm input status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| accountingRadiusStatus | 1.3.6.1.4.1.8603.1.1.2.0.350 | ||
| Accounting/RADIUS server status changed. | |||
| NOTIFICATION-TYPE | |||
| rrTimeStamp | |||
| rrSeqNum | |||
| rrSeverity | |||
| rrMoType | |||
| rrMoId | |||
| rrAddtlInfo | |||
| flarionTraps | 1.3.6.1.4.1.8603.10 | ||
| OBJECT IDENTIFIER | |||
| flaTrapVars | 1.3.6.1.4.1.8603.10.1 | ||
| OBJECT IDENTIFIER | |||
| flaTimeStamp | 1.3.6.1.4.1.8603.10.1.1 | ||
| The time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)). | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| flaSeqNum | 1.3.6.1.4.1.8603.10.1.2 | ||
| The event sequence number. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| flaSeverity | 1.3.6.1.4.1.8603.10.1.3 | ||
| The event severity. | |||
| OBJECT-TYPE | |||
| AlarmSeverity | |||
| flaMoType | 1.3.6.1.4.1.8603.10.1.4 | ||
| Type managed object associated with this trap. | |||
| OBJECT-TYPE | |||
| MoType | |||
| flaMoId | 1.3.6.1.4.1.8603.10.1.5 | ||
| The instance of the managed object logical identifier. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..65535 | ||
| flaAddtlInfo | 1.3.6.1.4.1.8603.10.1.6 | ||
| Event description. | |||
| OBJECT-TYPE | |||
| AddtlInfo | |||
| flaTraps | 1.3.6.1.4.1.8603.10.2 | ||
| OBJECT IDENTIFIER | |||
| flaTrapPrefix | 1.3.6.1.4.1.8603.10.2.0 | ||
| OBJECT IDENTIFIER | |||
| mcuBootStatusUp | 1.3.6.1.4.1.8603.10.2.0.1 | ||
| The MCU software is up and running. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| mcuBootStatusDown | 1.3.6.1.4.1.8603.10.2.0.2 | ||
| The MCU software is shutting down. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| mcuOperStatusUp | 1.3.6.1.4.1.8603.10.2.0.3 | ||
| MCU operational status is up. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| mcuOperStatusDown | 1.3.6.1.4.1.8603.10.2.0.4 | ||
| MCU operational status is down. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| mlpppStatusUp | 1.3.6.1.4.1.8603.10.2.0.5 | ||
| Multilink PPP status is up. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| mlpppStatusDown | 1.3.6.1.4.1.8603.10.2.0.6 | ||
| Multilink PPP status is up. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuOperStatusUp | 1.3.6.1.4.1.8603.10.2.0.7 | ||
| BBU card operational status is up. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuOperStatusDown | 1.3.6.1.4.1.8603.10.2.0.8 | ||
| BBU card operational status is down. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuOperStatusNotPresent | 1.3.6.1.4.1.8603.10.2.0.9 | ||
| BBU card operational status is not present. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuTempNormal | 1.3.6.1.4.1.8603.10.2.0.10 | ||
| BBU temperature has transitioned inot normal operating range. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuTempHigh | 1.3.6.1.4.1.8603.10.2.0.11 | ||
| BBU temperature has transitioned into a high operating range. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuTempSevere | 1.3.6.1.4.1.8603.10.2.0.12 | ||
| BBU temperature has transitioned into a severe operating range. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuTempCritical | 1.3.6.1.4.1.8603.10.2.0.13 | ||
| BBU temperature has transitioned into a critical operating range. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuVoltageNormal | 1.3.6.1.4.1.8603.10.2.0.14 | ||
| BBU voltage has transitioned into normal operating range. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuVoltageHigh | 1.3.6.1.4.1.8603.10.2.0.15 | ||
| BBU voltage has transitioned above normal operating limits. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| bbuVoltageLow | 1.3.6.1.4.1.8603.10.2.0.16 | ||
| BBU voltage has transitioned below normal operating limits. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| dspStatusActive | 1.3.6.1.4.1.8603.10.2.0.17 | ||
| DSP has transitioned into the Active state. In this state, mobiles are allowed to establish connections and data traffic can be received/transmitted. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| dspStatusStandby | 1.3.6.1.4.1.8603.10.2.0.18 | ||
| DSP has transitioned into the Disabled/Standby state. In this state, mobiles can not establish connections and data traffic can not be received/transmitted. This is typically caused by administrative intervention or the DSP has initiated this state change due to an alarm condition elsewhere in the system. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| dspStatusOos | 1.3.6.1.4.1.8603.10.2.0.19 | ||
| DSP has transitioned into the Out of Service state. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| dspStatusNonOperational | 1.3.6.1.4.1.8603.10.2.0.20 | ||
| DSP has transitioned into the Non Operational state. This state is entered when the system is unable to determine the condition of the DSP. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| accountingRadiusUp | 1.3.6.1.4.1.8603.10.2.0.21 | ||
| Accounting/RADIUS server is up. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||
| accountingRadiusDown | 1.3.6.1.4.1.8603.10.2.0.22 | ||
| Accounting/RADIUS server is down. | |||
| NOTIFICATION-TYPE | |||
| flaTimeStamp | |||
| flaSeqNum | |||
| flaSeverity | |||
| flaMoType | |||
| flaMoId | |||
| flaAddtlInfo | |||