FRDCE-OPT-MIB

File: FRDCE-OPT-MIB.mib (50993 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

mgmt NetworkAddress IpAddress
Counter Gauge TimeTicks
enterprises OBJECT-TYPE

Defined Objects

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PCTFRDCEPortTable 1.3.6.1.4.1.449.2.1.2.1.1.6
All of the configuration parameters relevant to the Frame Relay DCE Port table.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PCTFRDCEPortEntry

cdx6500PCTFRDCEPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.6.1
A row of SDLC Port configuration parameters.
OBJECT-TYPE    
  Cdx6500PCTFRDCEPortEntry  

cdx6500frdcepCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.6.1.1
Port Number.
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcepConnectionType 1.3.6.1.4.1.449.2.1.2.1.1.6.1.2
Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. newvalSimp - same functionality as 'simp', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER simp(0), newvalSimp(50)  

cdx6500frdcepClockSource 1.3.6.1.4.1.449.2.1.2.1.1.6.1.3
int - internal clock source. ext - external clock source. extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER int(0), ext(1), extint(2), extlp(3), newvalInt(50)  

cdx6500frdcepClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.6.1.4
This is the speed of the port in bits per second, when using internal clocking. Note that the maximum port speed is dependent on the type of hardware installed. Consult the users manual for details.
OBJECT-TYPE    
  INTEGER 1200..2048000  

cdx6500frdcepMaxStations 1.3.6.1.4.1.449.2.1.2.1.1.6.1.5
The highest station number to be configured on this FRA port. It is used to limit the configuration of stations.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepCtrlProtocol 1.3.6.1.4.1.449.2.1.2.1.1.6.1.6
Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. newvalAnnexD - same functionality as 'annexD', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER annexD(0), none(1), lmi(2), annexA(3), newvalAnnexD(50)  

cdx6500frdcepT391 1.3.6.1.4.1.449.2.1.2.1.1.6.1.7
This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepT392 1.3.6.1.4.1.449.2.1.2.1.1.6.1.8
This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN391 1.3.6.1.4.1.449.2.1.2.1.1.6.1.9
This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN392 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10
This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN393 1.3.6.1.4.1.449.2.1.2.1.1.6.1.11
This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNT1 1.3.6.1.4.1.449.2.1.2.1.1.6.1.12
This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNT2 1.3.6.1.4.1.449.2.1.2.1.1.6.1.13
This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN1 1.3.6.1.4.1.449.2.1.2.1.1.6.1.14
This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN2 1.3.6.1.4.1.449.2.1.2.1.1.6.1.15
This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN3 1.3.6.1.4.1.449.2.1.2.1.1.6.1.16
This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepSubaddress 1.3.6.1.4.1.449.2.1.2.1.1.6.1.17
Calls addressed to this node and with this subaddress will be routed to this port.
OBJECT-TYPE    
  DisplayString SIZE(0..3)  

cdx6500frdcepBiDirAnnexD 1.3.6.1.4.1.449.2.1.2.1.1.6.1.18
Whether ANSI T1.617 Annex D bi-directional procedures are enabled bi - Bi-directional procedures are enabled. uni - Uni-directional procedures are enabled. newvalBi - same functionality as 'bi', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER bi(0), uni(1), newvalBi(50)  

cdx6500frdcepInvertTXClock 1.3.6.1.4.1.449.2.1.2.1.1.6.1.19
This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert.
OBJECT-TYPE    
  INTEGER no(1), yes(2), nc(100)  

cdx6500frdcepControlProtocolOptions 1.3.6.1.4.1.449.2.1.2.1.1.6.1.20
These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)
OBJECT-TYPE    
  DisplayString SIZE(0..16)  

cdx6500frdcepDiscardControlOptions 1.3.6.1.4.1.449.2.1.2.1.1.6.1.21
This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames
OBJECT-TYPE    
  INTEGER none(1), debit(2)  

cdx6500frdcepElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.6.1.22
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500frdcepV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.6.1.23
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500frdcepHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.6.1.24
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
OBJECT IDENTIFIER    

cdx6500SPCTFRDCEStationTable 1.3.6.1.4.1.449.2.1.2.1.3.3
All of the configuration parameters relevant to the Frame Relay DCE Station table.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPCTFRDCEStationEntry

cdx6500SPCTFRDCEStationEntry 1.3.6.1.4.1.449.2.1.2.1.3.3.1
A row of Frame Relay DCE station configuration parameters.
OBJECT-TYPE    
  Cdx6500SPCTFRDCEStationEntry  

cdx6500frdcesCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.3.1.1
Station number.
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcesCfgDLCI 1.3.6.1.4.1.449.2.1.2.1.3.3.1.2
The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port. Its valid range is 16 - 1007. It must match the DLCI configured on the attached FRAD.
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesAutocallMnem 1.3.6.1.4.1.449.2.1.2.1.3.3.1.3
This is the mnemonic name used for auto calling. A blank indicates auto calling is disabled.
OBJECT-TYPE    
  DisplayString SIZE(0..8)  

cdx6500frdcesAutocallTimeout 1.3.6.1.4.1.449.2.1.2.1.3.3.1.4
This is the time interval in seconds between call attempts when auto calling.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesMaxAutocalls 1.3.6.1.4.1.449.2.1.2.1.3.3.1.5
This parameter is used to specify the number of times that this FRA station will attempt to call when auto calling is enabled. A value of zero will allow unlimited attempts.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesRemoteConnID 1.3.6.1.4.1.449.2.1.2.1.3.3.1.6
This parameter specifies the number of the remote LAN Connection or the number of the remote FRA station that this FRA station will attempt to connect to if configured for autocall.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPriority 1.3.6.1.4.1.449.2.1.2.1.3.3.1.7
This parameter specifies the Traffic Priority of this FRA station. newvalLow - same functionality as 'low', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER low(0), medium(1), high(2), expedite(3), newvalLow(50)  

cdx6500frdcesBillingRecords 1.3.6.1.4.1.449.2.1.2.1.3.3.1.8
This controls whether billing (accounting) records will be created for calls on this FRA station. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compliance.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), newvalDisabled(50)  

cdx6500frdcesStationNum 1.3.6.1.4.1.449.2.1.2.1.3.3.1.9
The number of the logical link on the line. This is the value of Sxx for routing purposes.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesMaxInboundQueue 1.3.6.1.4.1.449.2.1.2.1.3.3.1.10
This specifies the maximum number of frames which may be queued in the station's inbound queue. A smaller value may be choosen for applications which experience objectionable delays, if due to excessive growth of the station's inbound queue.
OBJECT-TYPE    
  INTEGER 100..2500  

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PPSTFRDCEPortTable 1.3.6.1.4.1.449.2.1.3.1.1.6
All of the statistics parameters relevant to the Frame Relay DCE Port table.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTFRDCEPortEntry

cdx6500PPSTFRDCEPortEntry 1.3.6.1.4.1.449.2.1.3.1.1.6.1
A row of Frame Relay DCE Port statistics parameters.
OBJECT-TYPE    
  Cdx6500PPSTFRDCEPortEntry  

cdx6500frdcepStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.1.6.1.1
Port Number.
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcepPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.6.1.2
Port Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - Port is down. disabled - Port has been disabled. enabled - port has been enabled, but is not yet Up. busyOut - port has been set to be disabled as soon as last active call is disestablished. No new calls will be established. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), busyOut(2), up(3), down(4), newvalDisabled(50)  

cdx6500frdcepPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.6.1.3
This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.1.6.1.4
Pertcentage of Port input bandwidth in use.
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcepUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.1.6.1.5
Pertcentage of Port output bandwidth in use.
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcepCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.6
Number of message received since last node, port, or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcepCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.7
Number of message sent since last node, port, or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcepCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.8
Number of characters received per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.9
Number of characters received per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.10
Number of frames received since last node, port, or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcepFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.11
Number of frames sent since last node, port, or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcepFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.12
Average number of frames received per second during the previous minute
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.13
Average number of frames transmitted per second during the previous minute
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.14
Total number of overrun errors counted by the I/O driver.
OBJECT-TYPE    
  Counter16  

cdx6500frdcepUnderrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.15
Total number of underrun errors counted by the I/O driver.
OBJECT-TYPE    
  Counter16  

cdx6500frdcepCRCErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.16
Total number of CRC errors counted by the I/O driver.
OBJECT-TYPE    
  Counter16  

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500SPSTFRDCEStationTable 1.3.6.1.4.1.449.2.1.3.1.3.3
All of the statistics parameters relevant to the Frame Relay DCE Station (DLCI) table.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPSTFRDCEStationEntry

cdx6500SPSTFRDCEStationEntry 1.3.6.1.4.1.449.2.1.3.1.3.3.1
A row of Frame Relay DCE station (DLCI) Statistics parameters.
OBJECT-TYPE    
  Cdx6500SPSTFRDCEStationEntry  

cdx6500frdcesStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.3.3.1.1
Port Number.
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcesStatsDLCI 1.3.6.1.4.1.449.2.1.3.1.3.3.1.2
The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port.
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.3
The quantity of user bytes received on the line as a percentage of the maximum number of bytes that could have been received.
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcesUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.4
The quantity of user bytes sent on the line as a percentage of the maximum number of bytes that could have been received.
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcesMaxSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.3.1.5
Maximum number of SVCs available in the network.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCurrentSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.3.1.6
Number of SVCs currently in use.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCharInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.7
Total number of characters received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.8
Total number of characters sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.9
Average number of characters received per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.10
Average number of characters transmitted per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPktInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.11
Total number of Packets received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesPktOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.12
Total number of Packets sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesPktsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.13
Average number of Packets received per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPktsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.14
Average number of Packets transmitted per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPacketsQueued 1.3.6.1.4.1.449.2.1.3.1.3.3.1.15
Current number of packets buffered since since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.16
Total number of frames received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.17
Total number of frames sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.18
Average number of frames received per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.19
Average number of frames transmitted per second.
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesInfoFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.20
Number of data frames received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesInfoFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.21
Number of data frames sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesRNRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.22
Number of RNR frames received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesRNRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.23
Number of RNR frames sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesRRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.24
Number of RR frames received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesRRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.25
Number of RR frames sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesREJFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.26
Number of REJ frames received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesREJFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.27
Number of REJ frames sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesDataPktsIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.28
Number of data packets received since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesDataPktsOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.29
Number of data packets sent since last node, port, or station boot or statistics reset.
OBJECT-TYPE    
  Counter  

cdx6500frdcesResetStats 1.3.6.1.4.1.449.2.1.3.1.3.3.1.30
reset : Resets the specified Frame Relay station statistics. noReset : Do not reset the specified Frame Relay station statistics.
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500frdcesBoot 1.3.6.1.4.1.449.2.1.3.1.3.3.1.31
boot : Boots the specified Frame Relay station. noBoot : Do not boot the specified Frame Relay station.
OBJECT-TYPE    
  INTEGER boot(1), noBoot(2)  

cdx6500frdcesDisable 1.3.6.1.4.1.449.2.1.3.1.3.3.1.32
disable : Disables the specified Frame Relay station. noDisable : Do not disable the specified Frame Relay station.
OBJECT-TYPE    
  INTEGER disable(1), noDisable(2)  

cdx6500frdcesEnable 1.3.6.1.4.1.449.2.1.3.1.3.3.1.33
enable : Enable the specified Frame Relay station. noEnable : Do not enable the specified Frame Relay station.
OBJECT-TYPE    
  INTEGER enable(1), noEnable(2)  

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500ContFRATable 1.3.6.1.4.1.449.2.1.4.17
OBJECT IDENTIFIER    

cdx6500frdcepPContTable 1.3.6.1.4.1.449.2.1.4.17.1
Control parameters for FRA ports.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500frdcepPContEntry

cdx6500frdcepPContEntry 1.3.6.1.4.1.449.2.1.4.17.1.1
A row of FRA port control.
OBJECT-TYPE    
  Cdx6500frdcepPContEntry  

cdx6500frdcepContPortNumber 1.3.6.1.4.1.449.2.1.4.17.1.1.1
Port number of the FRA port.
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdcepContPortControl 1.3.6.1.4.1.449.2.1.4.17.1.1.2
Control operations for the specified FRA port. boot - Boots the FRA port enable - Enables the FRA port disable - Disables the FRA port resetstats - Resets the FRA port statistics.
OBJECT-TYPE    
  INTEGER boot(1), enable(2), disable(3), resetstats(4)  

cdx6500frdcesSContTable 1.3.6.1.4.1.449.2.1.4.17.2
Control parameter for Fra stations
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500frdcesSContEntry

cdx6500frdcesSContEntry 1.3.6.1.4.1.449.2.1.4.17.2.1
A row of FRA Station control
OBJECT-TYPE    
  Cdx6500frdcesSContEntry  

cdx6500frdcesStationPortNumber 1.3.6.1.4.1.449.2.1.4.17.2.1.1
Fra Station Port number
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdcesStationDLCI 1.3.6.1.4.1.449.2.1.4.17.2.1.2
Fra Station DLCI number
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesStationControl 1.3.6.1.4.1.449.2.1.4.17.2.1.3
Control operations for the specified FRA station. boot - Boot the FRA station enable - Enables the FRA station disable - Disables the FRA station resetstats - Resets the FRA station statistics.
OBJECT-TYPE    
  INTEGER boot(1), enable(2), disable(3), resetstats(4)  

Defined Objects

Counter16  
INTEGER 0..65535    

DisplayString  
OCTET STRING    

PhysAddress  
OCTET STRING    

Cdx6500PCTFRDCEPortEntry  
SEQUENCE    
  INTEGER as cdx6500frdcepCfgPortNum  
  INTEGER as cdx6500frdcepConnectionType  
  INTEGER as cdx6500frdcepClockSource  
  INTEGER as cdx6500frdcepClockSpeed  
  INTEGER as cdx6500frdcepMaxStations  
  INTEGER as cdx6500frdcepCtrlProtocol  
  INTEGER as cdx6500frdcepT391  
  INTEGER as cdx6500frdcepT392  
  INTEGER as cdx6500frdcepN391  
  INTEGER as cdx6500frdcepN392  
  INTEGER as cdx6500frdcepN393  
  INTEGER as cdx6500frdcepNT1  
  INTEGER as cdx6500frdcepNT2  
  INTEGER as cdx6500frdcepNN1  
  INTEGER as cdx6500frdcepNN2  
  INTEGER as cdx6500frdcepNN3  
  DisplayString as cdx6500frdcepSubaddress  
  INTEGER as cdx6500frdcepBiDirAnnexD  
  INTEGER as cdx6500frdcepInvertTXClock  
  DisplayString as cdx6500frdcepControlProtocolOptions  
  INTEGER as cdx6500frdcepDiscardControlOptions  
  INTEGER as cdx6500frdcepElectricalInterfaceType  
  INTEGER as cdx6500frdcepV24ElectricalInterfaceOption  
  INTEGER as cdx6500frdcepHighSpeedElectricalInterfaceOption  

Cdx6500PPSTFRDCEPortEntry  
SEQUENCE    
  INTEGER as cdx6500frdcepStatsPortNum  
  INTEGER as cdx6500frdcepPortStatus  
  INTEGER as cdx6500frdcepPortSpeed  
  INTEGER as cdx6500frdcepUtilizationIn  
  INTEGER as cdx6500frdcepUtilizationOut  
  Counter as cdx6500frdcepCharInTotal  
  Counter as cdx6500frdcepCharOutTotal  
  INTEGER as cdx6500frdcepCharsInPerSec  
  INTEGER as cdx6500frdcepCharsOutPerSec  
  Counter as cdx6500frdcepFrameInTotal  
  Counter as cdx6500frdcepFrameOutTotal  
  INTEGER as cdx6500frdcepFramesInPerSec  
  INTEGER as cdx6500frdcepFramesOutPerSec  
  Counter16 as cdx6500frdcepOverrunErrors  
  Counter16 as cdx6500frdcepUnderrunErrors  
  Counter16 as cdx6500frdcepCRCErrors  

Cdx6500SPCTFRDCEStationEntry  
SEQUENCE    
  INTEGER as cdx6500frdcesCfgPortNum  
  INTEGER as cdx6500frdcesCfgDLCI  
  DisplayString as cdx6500frdcesAutocallMnem  
  INTEGER as cdx6500frdcesAutocallTimeout  
  INTEGER as cdx6500frdcesMaxAutocalls  
  INTEGER as cdx6500frdcesRemoteConnID  
  INTEGER as cdx6500frdcesPriority  
  INTEGER as cdx6500frdcesBillingRecords  
  INTEGER as cdx6500frdcesStationNum  
  INTEGER as cdx6500frdcesMaxInboundQueue  

Cdx6500SPSTFRDCEStationEntry  
SEQUENCE    
  INTEGER as cdx6500frdcesStatsPortNum  
  INTEGER as cdx6500frdcesStatsDLCI  
  INTEGER as cdx6500frdcesUtilizationIn  
  INTEGER as cdx6500frdcesUtilizationOut  
  INTEGER as cdx6500frdcesMaxSVCCount  
  INTEGER as cdx6500frdcesCurrentSVCCount  
  Counter as cdx6500frdcesCharInTotal  
  Counter as cdx6500frdcesCharOutTotal  
  INTEGER as cdx6500frdcesCharsInPerSec  
  INTEGER as cdx6500frdcesCharsOutPerSec  
  Counter as cdx6500frdcesPktInTotal  
  Counter as cdx6500frdcesPktOutTotal  
  INTEGER as cdx6500frdcesPktsInPerSec  
  INTEGER as cdx6500frdcesPktsOutPerSec  
  INTEGER as cdx6500frdcesPacketsQueued  
  Counter as cdx6500frdcesFrameInTotal  
  Counter as cdx6500frdcesFrameOutTotal  
  INTEGER as cdx6500frdcesFramesInPerSec  
  INTEGER as cdx6500frdcesFramesOutPerSec  
  Counter as cdx6500frdcesInfoFramesIn  
  Counter as cdx6500frdcesInfoFramesOut  
  Counter as cdx6500frdcesRNRFramesIn  
  Counter as cdx6500frdcesRNRFramesOut  
  Counter as cdx6500frdcesRRFramesIn  
  Counter as cdx6500frdcesRRFramesOut  
  Counter as cdx6500frdcesREJFramesIn  
  Counter as cdx6500frdcesREJFramesOut  
  Counter as cdx6500frdcesDataPktsIn  
  Counter as cdx6500frdcesDataPktsOut  
  INTEGER as cdx6500frdcesResetStats  
  INTEGER as cdx6500frdcesBoot  
  INTEGER as cdx6500frdcesDisable  
  INTEGER as cdx6500frdcesEnable  

Cdx6500frdcepPContEntry  
SEQUENCE    
  INTEGER as cdx6500frdcepContPortNumber  
  INTEGER as cdx6500frdcepContPortControl  

Cdx6500frdcesSContEntry  
SEQUENCE    
  INTEGER as cdx6500frdcesStationPortNumber  
  INTEGER as cdx6500frdcesStationDLCI  
  INTEGER as cdx6500frdcesStationControl