Fore-Apsgroup-MIB

File: Fore-Apsgroup-MIB.mib (11683 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC Fore-Common-MIB
Fore-TrapLog-MIB Fore-Switch-MIB

Imported symbols

Integer32 OBJECT-TYPE NOTIFICATION-TYPE
MODULE-IDENTITY DisplayString atmSwitch
asx trapLogIndex hwPortName
hwPortBoard hwPortModule hwPortNumber

Defined Objects

apsSwitchOver 1.3.6.1.4.1.326.2.2.0.2017
This trap alerts that an aps switchover has occurred and the active port is identified by the tuple {hwPortBoard, hwPortModule, hwPortNumber}.
NOTIFICATION-TYPE    
  hwPortName  
  hwPortBoard  
  hwPortModule  
  hwPortNumber  
  trapLogIndex  

foreAps 1.3.6.1.4.1.326.2.2.1.1.16
SONET APS
MODULE-IDENTITY    

apsPortGroup 1.3.6.1.4.1.326.2.2.1.1.16.1
OBJECT IDENTIFIER    

apsPortTable 1.3.6.1.4.1.326.2.2.1.1.16.1.1
A table of SONET APS port configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    ApsPortEntry

apsPortEntry 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1
A table entry containing SONET APS configuration information for each APS port.
OBJECT-TYPE    
  ApsPortEntry  

apsBoard 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.1
The index of this port's switch board.
OBJECT-TYPE    
  Integer32  

apsModule 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.2
The network module of this port.
OBJECT-TYPE    
  Integer32  

apsPort 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.3
The number of this port.
OBJECT-TYPE    
  Integer32  

apsAdminMode 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.4
This variable indicates the APS configuration for this port. Unprotected indicates that APS is not configured for this port. Working indicates that this port is a working channel. Protection indicates that this port is a protection channel.
OBJECT-TYPE    
  INTEGER working(1), protection(2), unprotected(3)  

apsOperMode 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.5
This variable indicates if this port is an active or standby APS channel. If APS is not configured for this port, the mode is notApplicable. loopbackOn indicates that the port is configured in the loopback mode and is the port on which the loopback has been enabled(or is under test). loopbackOff indicates that the port is configured in the loopback mode and is the port which is in the disabled state (not under test).
OBJECT-TYPE    
  INTEGER active(1), standby(2), notApplicable(3), loopbackOn(4), loopbackOff(5)  

apsPortGroupName 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.6
This object identifies the APS group this port is associated with.
OBJECT-TYPE    
  DisplayString  

apsGroup 1.3.6.1.4.1.326.2.2.1.1.16.2
OBJECT IDENTIFIER    

apsGroupTable 1.3.6.1.4.1.326.2.2.1.1.16.2.1
A table of SONET APS port group configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    ApsGroupEntry

apsGroupEntry 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1
A table entry containing SONET APS configuration information for each APS group.
OBJECT-TYPE    
  ApsGroupEntry  

apsGroupName 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.1
This object identifies the APS group. of all the ports associated with this group.
OBJECT-TYPE    
  DisplayString  

apsGroupStateCommand 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.2
A user initiated APS command. Note this object is write-only and reading it will result in implementation-specific results.
OBJECT-TYPE    
  INTEGER clear(1), lockout(2), forceSwitchToWorking(3), forceSwitchToProtection(4), manualSwitchToWorking(5), manualSwitchToProtection(6)  

apsGroupLastCommand 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.3
Last Aps Command issued by the user.
OBJECT-TYPE    
  INTEGER clear(1), lockout(2), forceSwitchToWorking(3), forceSwitchToProtection(4), manualSwitchToWorking(5), manualSwitchToProtection(6), suspendWorking(7), suspendProtection(8), noRequest(9)  

apsWorkingLineState 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.4
Line State of the Working Port of the APS Group.
OBJECT-TYPE    
  INTEGER signalFailure(1), signalDegrade(2), none(3), notAvailable(4)  

apsProtectionLineState 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.5
Line State of the Protection Port of the APS Group.
OBJECT-TYPE    
  INTEGER signalFailure(1), signalDegrade(2), none(3), notAvailable(4)  

apsGroupMode 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.6
This variable indicates the APS switching mode for this APS group.
OBJECT-TYPE    
  INTEGER uni-directional(1), bi-directional(2)  

apsRxK1K2 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.7
Command specified in the received K1K2 bytes.
OBJECT-TYPE    
  INTEGER lockout(1), forceSwitch(2), manualSwitch(3), signalFailure(4), signalDegrade(5), exercise(6), waitToRestore(7), reverseRequest(8), doNotRevert(9), noRequest(10), none(11), notAvailable(12)  

apsRxChannel 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.8
Channel specified in received K1K2 bytes.
OBJECT-TYPE    
  INTEGER working(1), protection(2), not-applicable(3)  

apsTxK1K2 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.9
Command specified in the transmitted K1K2 bytes.
OBJECT-TYPE    
  INTEGER lockout(1), forceSwitch(2), manualSwitch(3), signalFailure(4), signalDegrade(5), exercise(6), waitToRestore(7), reverseRequest(8), doNotRevert(9), noRequest(10), none(11), notAvailable(12)  

apsTxChannel 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.10
Channel specified in transmitted K1K2 bytes.
OBJECT-TYPE    
  INTEGER working(1), protection(2), not-applicable(3)  

apsRevertMode 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.11
APS revertive mode configuration
OBJECT-TYPE    
  INTEGER on(1), off(2)  

apsRevertTimer 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.12
APS revertive timer value in minutes
OBJECT-TYPE    
  Integer32  

Defined Objects

ApsPortEntry  
SEQUENCE    
  Integer32 as apsBoard  
  Integer32 as apsModule  
  Integer32 as apsPort  
  INTEGER as apsAdminMode  
  INTEGER as apsOperMode  
  DisplayString as apsPortGroupName  

ApsGroupEntry  
SEQUENCE    
  DisplayString as apsGroupName  
  INTEGER as apsGroupStateCommand  
  INTEGER as apsGroupLastCommand  
  INTEGER as apsWorkingLineState  
  INTEGER as apsProtectionLineState  
  INTEGER as apsGroupMode  
  INTEGER as apsRxK1K2  
  INTEGER as apsRxChannel  
  INTEGER as apsTxK1K2  
  INTEGER as apsTxChannel  
  INTEGER as apsRevertMode  
  Integer32 as apsRevertTimer