Fore-DS1-MIB

File: Fore-DS1-MIB.mib (25921 bytes)

Imported modules

SNMPv2-SMI Fore-Common-MIB

Imported symbols

Counter32 Integer32 OBJECT-TYPE
MODULE-IDENTITY asx

Defined Objects

foreDs1 1.3.6.1.4.1.326.2.2.1.1.7
Fore DS1 mib module for supporting the DS1 port module.
MODULE-IDENTITY    

ds1ConfGroup 1.3.6.1.4.1.326.2.2.1.1.7.1
OBJECT IDENTIFIER    

ds1ConfTable 1.3.6.1.4.1.326.2.2.1.1.7.1.1
A table of DS1 switch port configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1ConfEntry

ds1ConfEntry 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1
A table entry containing DS1 configuration information for each port. Not all RFC1406 configuration table variables are included, and some are modified.
OBJECT-TYPE    
  Ds1ConfEntry  

ds1ConfBoard 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.1
The index of this port's switch board.
OBJECT-TYPE    
  Integer32  

ds1ConfModule 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.2
The network module of this port.
OBJECT-TYPE    
  Integer32  

ds1ConfPort 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.3
The number of this port.
OBJECT-TYPE    
  Integer32  

ds1LineType 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.4
This variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. This variable is defined in the rfc1406 configuration table as dsx1LineType. According to rfc1406, the different values are: ds1ESF Extended SuperFrame DS1 ds1D4 AT&T D4 format DS1.
OBJECT-TYPE    
  INTEGER ds1Other(1), ds1ESF(2), ds1D4(3)  

ds1LineCoding 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.5
This variable describes the variety of Zero Code suppression used on this link, which in turn affects a number of its characteristics. ds1B8ZS (2) refers to the use of specified pattern of normal bits and bipolar violations which are used to replaced sequences of eight zero bits. This variable is defined in the rfc1406 configuration table as dsx1LineCoding.
OBJECT-TYPE    
  INTEGER ds1Other(1), ds1JBZS(2), ds1B8ZS(3), ds1HDB3(4), ds1ZBTSI(5), ds1AMI(6)  

ds1SendCode 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.6
This variable indicates what type of code is being sent across the DS1 interface by the device. The values mean: ds1SendNoCode sending looped or normal data ds1SendLineCode sending request for a line loopback ds1SendPayloadCode sending a request for a payload loopback ds1SendResetCode sending a loopback termination request ds1SendQRS sending a Quasi-Random Signal (QRS) test pattern ds1Send511Pattern sending a 511 bit fixed test pattern ds1Send3in24Pattern sending a fixed test pattern of 3 bits set in 24 ds1SendTestPattern sending a test pattern other than the above.
OBJECT-TYPE    
  INTEGER ds1SendNoCode(1), ds1SendLineCode(2), ds1SendPayloadCode(3), ds1SendResetCode(4), ds1SendQRS(5), ds1Send511Pattern(6), ds1Send3in24Pattern(7), ds1SendOtherTestPattern(8)  

ds1ReceiveCode 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.7
This variable indicates the type of code that was received across the DS interface. The values mean: ds1ReceiveNoCode receiving looped or normal data ds1ReceiveLineCode receiving request for a line loopback ds1ReceivePayloadCode receiving a request for a payload loopback ds1ReceiveResetCode receiving a loopback deactivation request ds1ReceiveQRS receiving a Quasi-Random Signal (QRS) test pattern ds1Receive511Pattern receiving a 511 bit fixed test pattern ds1Receive3in24Pattern receiving a fixed test pattern of 3 bits set in 24 ds1ReceiveTestPattern receiving a test pattern other than the above.
OBJECT-TYPE    
  INTEGER ds1ReceiveNoCode(1), ds1ReceiveLineCode(2), ds1ReceivePayloadCode(3), ds1ReceiveResetCode(4), ds1SendQRS(5), ds1Send511Pattern(6), ds1Send3in24Pattern(7), ds1SendOtherTestPattern(8)  

ds1LoopbackConfig 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.8
This variable represents the loopback configuration of the DS1 interface. This variable is defined in the rfc1406 configuration table as dsx1LoopbackConfig, with slightly different values. ds1NoLoop (1) means that the interface is not in a loopback state. ds1LineLoop (2) means that cells that are processed by the receiving component are not written into the receive FIFO, but into the transmit FIFO for retransmission. ds1PayloadLoop (3) means that the receive signal is looped back for retransmission after it has passed through the port's reframing function. ds1DiagLoop (4) means that the transmit data stream is looped back to the receiver. ds1OtherLoop (5) means that the interface is in a loopback that is not defined here.
OBJECT-TYPE    
  INTEGER ds1NoLoop(1), ds1LineLoop(2), ds1PayloadLoop(3), ds1DiagLoop(4), ds1OtherLoop(5)  

ds1TxClockSource 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.9
The source of the transmit clock. rxTiming(1) indicated that the recovered receive clock is used as the transmit clock. localTiming(2) indicates that a local source clock is used as the transmit clock. To determine which local source clock is used advise the ntGlobalClock in the netmodTimingTable for this netmod (refer to the Fore-Switch-MIB for more information).
OBJECT-TYPE    
  INTEGER rxTiming(1), localTiming(2)  

ds1LineStatus 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.12
This variable indicates the Line Status of the interface. A similar object is defined in the rfc1406 configuration table as dsx1LineStatus. The variable contains loopback state information and failure state information. It is a bit map represented as a sum. The ds1NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1 No Alarm. 2 Receiving PLCP Yellow Alarm Indication. 4 Transmitting PLCP Yellow alarm indication. 8 Receiving PLCP LOF. 16 Receiving DS1 Yellow Alarm Indication. 32 Transmiting DS1 Yellow Alarm Indication. 64 Receiving AIS failure indication. 128 Receiving LOF failure indication. 256 Receiving LOS failure indication. 512 Loopback State. 1024 Receiving a test pattern. 2048 Other failures. 4096 Receiving Excessive CRC Errors. 32768 Receiving LCD failure indication.
OBJECT-TYPE    
  Integer32 1..65534  

ds1IdleUnassignedCells 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.13
This variable indicates the types of cells that should be sent in case there is no real data to send. According to the ATM Forum, Unassigned cells should be sent (octet 1-3 are 0's, octet 4 is 0000xxx0, where x is 'don't care'). According to the CCITT specifications, Idle cells should be sent (everything is '0' except for the CLP bit which is '1'). By default, unassigned cells are transmitted is case there is no data to send.
OBJECT-TYPE    
  INTEGER unassigned(1), idle(2)  

ds1LineTypeFraming 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.14
This variable indicates the way ATM cells are constructed from the DS1 stream. ds1Hcs(2) indicates that the ATM cells are constructed upon the Header Check Sequence (HCS) inside the ATM cell header. ds1Plcp(3) indicates that the ATM cells are constructed from the DS1 PLCP (Physical Layer Convergence Protocol) bits.
OBJECT-TYPE    
  INTEGER other(1), ds1Hcs(2), ds1Plcp(3)  

ds1LineLength 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.15
This variable represents the length of the physical cable connected to the ds1 port. The user has to set this object to match the physical cable in order to get the netmod to receive the signal on the cable. The different values are: ds1LineLt110 (1) means the line is shorter than 110 ft, ds1Line110-220 (2) means the line length is between 110 and 220 ft, ds1Line220-330 (3) means the line length is between 220 and 330 ft, ds1Line330-440 (4) means the line length is between 330 and 440 ft, ds1Line440-550 (5) means the line length is between 440 and 550 ft, ds1Line550-660 (6) means the line length is between 550 and 660 ft, ds1LineGt655 (7) means the line is longer than 655 ft.
OBJECT-TYPE    
  INTEGER ds1LineLt110(1), ds1Line110-220(2), ds1Line220-330(3), ds1Line330-440(4), ds1Line440-550(5), ds1Line550-660(6), ds1LineGt655(7), ds1LineLt110Alt(9), ds1Line110-220Alt(10), ds1Line220-330Alt(11), ds1Line330-440Alt(12), ds1Line440-550Alt(13), ds1Line550-660Alt(14), ds1LineGt655Alt(15)  

ds1RxScrambling 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.16
This variable indicates whether the information is being descrambled on receiving. It should be set the same as the transmitting side.
OBJECT-TYPE    
  INTEGER descrambling(1), noDescrambling(2)  

ds1TxScrambling 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.17
This variable indicates whether the information (48 octet payload) is being scrambled before transmitting. It should be set the same as the receiving side.
OBJECT-TYPE    
  INTEGER scrambling(1), noScrambling(2)  

ds1TxPRBS 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.18
This variable controls the Pseudo-Random Bit Sequence Generator (PRSG) which generates an unframed 2^15-1 test sequence as define in Recommendation O.151. The pattern may be inverted.
OBJECT-TYPE    
  INTEGER off(1), on(2), invert(3)  

ds1CRCErrThrSeconds 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.19
This variable represents the consecutive number of BAD/GOOD seconds to detect/clear an Excessive CRC Error Defect. The range of values it can take is between 2 and 10 inclusive.
OBJECT-TYPE    
  Integer32  

ds1CRCErrThrErrors 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.20
This variable is a threshold for the number of CRC Errors per second and is used as a parameter to the Excessive CRC Error Defect. If the number of errors exceeds the threshold, the particular second is declared BAD, otherwise it is declared GOOD.
OBJECT-TYPE    
  Integer32  

ds1CRCErrFailEnable 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.21
This variable controls whether declaration of an Excessive CRC Error Defect forces the port's operState to Down.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ds1SigFailBer 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.22
This is the exponent of 10 for the current signal fail bit error rate (BER) threshold for this port. The value -4, for example, represents a BER of 1E-4. This variable is only applicable when ds1BerErrorModel is set to errorModelRandom.
OBJECT-TYPE    
  Integer32  

ds1SigDegradeBer 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.23
This is the exponent of 10 for the current signal degrade bit error rate (BER) threshold for this port. The value -8, for example, represents a BER of 1E-8. This variable is only applicable when ds1BerErrorModel is set to errorModelRandom.
OBJECT-TYPE    
  Integer32  

ds1BerErrorModel 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.24
This is the error distribution model to be used to identify signal degrade and signal fail conditions. errorModelRandom selects a random error distribution and declares signal conditions based on the thresholds set in ds1SigDegradeBer and ds1SigFailBer. errorModelBurst selects a burst error model and declares signal degrade conditions based on the thresholds set in ds1CRCErrThrSeconds and ds1CRCErrThrErrors. errorModelNone disables detection of signal conditions.
OBJECT-TYPE    
  INTEGER errorModelNone(0), errorModelRandom(1), errorModelBurst(2)  

ds1BerState 1.3.6.1.4.1.326.2.2.1.1.7.1.1.1.25
This value describes the current state of the port as determined through bit error rate analysis.
OBJECT-TYPE    
  INTEGER berStateOk(0), berStateSigDegrade(1), berStateSigFail(2)  

ds1StatsGroup 1.3.6.1.4.1.326.2.2.1.1.7.2
OBJECT IDENTIFIER    

ds1FramingTable 1.3.6.1.4.1.326.2.2.1.1.7.2.1
A table of DS1 framing statistics information.
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1FramingEntry

ds1FramingEntry 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1
A table entry containing DS1 framing statistics information.
OBJECT-TYPE    
  Ds1FramingEntry  

ds1FramingBoard 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.1
The index of this port's switch board.
OBJECT-TYPE    
  Integer32  

ds1FramingModule 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.2
The network module of this port.
OBJECT-TYPE    
  Integer32  

ds1FramingPort 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.3
The number of this port.
OBJECT-TYPE    
  Integer32  

ds1FramingLOSs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.4
The number of seconds in which Loss Of Signal (LOS) errors have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingLCVs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.5
The number of Line Code Violations (LCV) that have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingFERRs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.6
The number of Framing ERRor (FERR) events that have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingOOFs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.7
The number of Out Of Frame (OOF) error events that have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingAISs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.8
The number of seconds in which Alarm Indication Signals (AIS) have been detected. AIS indicates that an upstream failure has been detected by the far end.
OBJECT-TYPE    
  Counter32  

ds1FramingB8ZSPatterns 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.9
The number of seconds in which B8ZS Pattern events have been detected.
OBJECT-TYPE    
  Counter32  

ds1Framing8Zeros 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.10
The number of seconds in which 8 Zeros events have been detected.
OBJECT-TYPE    
  Counter32  

ds1Framing16Zeros 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.11
The number of seconds in which 16 Zeros events have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingYellowAlarms 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.12
The number of seconds in which Yellow Alarm events have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingRedAlarms 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.13
The number of seconds in which Red Alarm events have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingBEEs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.14
The number of Bit Encoding Error (BEE) events that have been detected. A Bit Error Event is defined as a CRC-6 error in ESF.
OBJECT-TYPE    
  Counter32  

ds1FramingPRBSs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.15
The number of seconds in which Pseudo Random Bit Sequence (PRBS) patterns have been detected.
OBJECT-TYPE    
  Counter32  

ds1FramingBERs 1.3.6.1.4.1.326.2.2.1.1.7.2.1.1.16
The number of PRBS Bit ERror events that have been detected.
OBJECT-TYPE    
  Counter32  

ds1PlcpTable 1.3.6.1.4.1.326.2.2.1.1.7.2.2
A table of DS1 Physical Layer Convergence Protocol (Procedure) statistics information.
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1PlcpEntry

ds1PlcpEntry 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1
A table entry containing DS1 PLCP statistics information.
OBJECT-TYPE    
  Ds1PlcpEntry  

ds1PlcpBoard 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.1
The index of this port's switch board.
OBJECT-TYPE    
  Integer32  

ds1PlcpModule 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.2
The network module of this port.
OBJECT-TYPE    
  Integer32  

ds1PlcpPort 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.3
The number of this port.
OBJECT-TYPE    
  Integer32  

ds1PlcpBIP8s 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.4
Number of BIP-8 (Bit Interleaved Parity - 8) error events. The BIP-8 is calculated over the Path Overhead field and the associated ATM cell of the previous frame. A BIP-N is a method of error monitoring. An N bit code is generated by the transmitting equipment in such a manner that the first bit of the code provides even parity over the first bit of all N-bit sequences in the previous VT SPE, the second bit provides even parity over the second bits of all N-bit sequences within the specified portion, etc.
OBJECT-TYPE    
  Counter32  

ds1PlcpFERRs 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.5
Number of Physical Layer Convergence Protocol (PLCP) octet error events.
OBJECT-TYPE    
  Counter32  

ds1PlcpFEBEs 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.6
Number of ATM Far End Block Error (FEBE) events.
OBJECT-TYPE    
  Counter32  

ds1PlcpLOFs 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.7
The number of seconds in which Loss Of Frame (LOF) errors were detected by the PLCP (Physical Layer Convergence Protocol) receiver. LOF is declared when an Out-Of-Frame state persists for more than 1ms. LOF is removed when in-frame state persists for more than 12ms.
OBJECT-TYPE    
  Counter32  

ds1PlcpYellows 1.3.6.1.4.1.326.2.2.1.1.7.2.2.1.8
The number of seconds in which Yellow alarm errors were detected by the PLCP (Physical Layer Convergence Protocol) receiver. Yellow alarm is asserted when 10 consecutive yellow signal bits are set to logical 1. Yellow signals are used to alert upstream terminals of a downstream failure in order to initiate trunk conditioning on the failure circuit.
OBJECT-TYPE    
  Counter32  

ds1AtmTable 1.3.6.1.4.1.326.2.2.1.1.7.2.3
A table of DS1 ATM statistics information.
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1AtmEntry

ds1AtmEntry 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1
A table entry containing DS1 ATM statistics information.
OBJECT-TYPE    
  Ds1AtmEntry  

ds1AtmBoard 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.1
The index of this port's switch board.
OBJECT-TYPE    
  Integer32  

ds1AtmModule 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.2
The network module of this port.
OBJECT-TYPE    
  Integer32  

ds1AtmPort 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.3
The number of this port.
OBJECT-TYPE    
  Integer32  

ds1AtmHCSs 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.4
Number of header check sequence (HCS) error events. The HCS is a CRC-8 calculation over the first 4 octets of the ATM cell header.
OBJECT-TYPE    
  Counter32  

ds1AtmRxCells 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.5
Number of ATM cells that were received.
OBJECT-TYPE    
  Counter32  

ds1AtmTxCells 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.6
Number of non-null ATM cells that were transmitted.
OBJECT-TYPE    
  Counter32  

ds1AtmUHCSs 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.7
Number of uncorrectable header check sequence (UHCS) error events. The HCS is a CRC-8 calculation over the first 4 octets of the ATM cell header.
OBJECT-TYPE    
  Counter32  

ds1AtmCHCSs 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.8
Number of correctable header check sequence (UHCS) error events. The HCS is a CRC-8 calculation over the first 4 octets of the ATM cell header.
OBJECT-TYPE    
  Counter32  

ds1AtmLCDs 1.3.6.1.4.1.326.2.2.1.1.7.2.3.1.9
The number of seconds in which Loss of Cell Delineation (LCD) has occurred. An LCD defect is detected when an out of cell delination state has persisted for 4ms. An LCD defect is cleared when the sync state has been maintained for 4ms.
OBJECT-TYPE    
  Counter32  

Defined Objects

Ds1ConfEntry  
SEQUENCE    
  Integer32 as ds1ConfBoard  
  Integer32 as ds1ConfModule  
  Integer32 as ds1ConfPort  
  INTEGER as ds1LineType  
  INTEGER as ds1LineCoding  
  INTEGER as ds1SendCode  
  INTEGER as ds1ReceiveCode  
  INTEGER as ds1LoopbackConfig  
  INTEGER as ds1TxClockSource  
  Integer32 as ds1LineStatus  
  INTEGER as ds1IdleUnassignedCells  
  INTEGER as ds1LineTypeFraming  
  INTEGER as ds1LineLength  
  INTEGER as ds1RxScrambling  
  INTEGER as ds1TxScrambling  
  INTEGER as ds1TxPRBS  
  Integer32 as ds1CRCErrThrSeconds  
  Integer32 as ds1CRCErrThrErrors  
  INTEGER as ds1CRCErrFailEnable  
  Integer32 as ds1SigFailBer  
  Integer32 as ds1SigDegradeBer  
  INTEGER as ds1BerErrorModel  
  INTEGER as ds1BerState  

Ds1FramingEntry  
SEQUENCE    
  Integer32 as ds1FramingBoard  
  Integer32 as ds1FramingModule  
  Integer32 as ds1FramingPort  
  Counter32 as ds1FramingLOSs  
  Counter32 as ds1FramingLCVs  
  Counter32 as ds1FramingFERRs  
  Counter32 as ds1FramingOOFs  
  Counter32 as ds1FramingAISs  
  Counter32 as ds1FramingB8ZSPatterns  
  Counter32 as ds1Framing8Zeros  
  Counter32 as ds1Framing16Zeros  
  Counter32 as ds1FramingYellowAlarms  
  Counter32 as ds1FramingRedAlarms  
  Counter32 as ds1FramingBEEs  
  Counter32 as ds1FramingPRBSs  
  Counter32 as ds1FramingBERs  

Ds1PlcpEntry  
SEQUENCE    
  Integer32 as ds1PlcpBoard  
  Integer32 as ds1PlcpModule  
  Integer32 as ds1PlcpPort  
  Counter32 as ds1PlcpBIP8s  
  Counter32 as ds1PlcpFERRs  
  Counter32 as ds1PlcpFEBEs  
  Counter32 as ds1PlcpLOFs  
  Counter32 as ds1PlcpYellows  

Ds1AtmEntry  
SEQUENCE    
  Integer32 as ds1AtmBoard  
  Integer32 as ds1AtmModule  
  Integer32 as ds1AtmPort  
  Counter32 as ds1AtmHCSs  
  Counter32 as ds1AtmRxCells  
  Counter32 as ds1AtmTxCells  
  Counter32 as ds1AtmUHCSs  
  Counter32 as ds1AtmCHCSs  
  Counter32 as ds1AtmLCDs