| RFC-1212 | RFC-1215 | RFC1155-SMI |
| SNMPv2-SMI |
| OBJECT-TYPE | TRAP-TYPE | IpAddress |
| enterprises |
| huawei | 1.3.6.1.4.1.2011 | ||
| OBJECT IDENTIFIER | |||
| products | 1.3.6.1.4.1.2011.2 | ||
| OBJECT IDENTIFIER | |||
| hwNetManagement | 1.3.6.1.4.1.2011.2.15 | ||
| OBJECT IDENTIFIER | |||
| hwNmAgent | 1.3.6.1.4.1.2011.2.15.1 | ||
| OBJECT IDENTIFIER | |||
| hwNmFault | 1.3.6.1.4.1.2011.2.15.1.3 | ||
| OBJECT IDENTIFIER | |||
| thirdNMSFaultFilter | 1.3.6.1.4.1.2011.2.15.1.3.5 | ||
| This is to add the filter condition by the upper NMS the syntax is IP:Port:Alarm Level Example : 127.0.0.1:161:0011 In this IP is 127.0.0.1 Port is 161 Alarm Level - Minor and warning should not be sent as the bit is set for them | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(14..32) | ||
| hwNmNorthboundEvent | 1.3.6.1.4.1.2011.2.15.1.7 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventInfo | 1.3.6.1.4.1.2011.2.15.1.7.1 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundNEName | 1.3.6.1.4.1.2011.2.15.1.7.1.1 | ||
| The name of network element,string (255) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundNEType | 1.3.6.1.4.1.2011.2.15.1.7.1.2 | ||
| Device type of element,string(64) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundObjectInstance | 1.3.6.1.4.1.2011.2.15.1.7.1.3 | ||
| Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| hwNmNorthboundEventType | 1.3.6.1.4.1.2011.2.15.1.7.1.4 | ||
| Event type of Network management,string(64) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundEventTime | 1.3.6.1.4.1.2011.2.15.1.7.1.5 | ||
| Alarm generate time,string(64),format: 2003/03/14 00:00:00 | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundProbableCause | 1.3.6.1.4.1.2011.2.15.1.7.1.6 | ||
| Reason of Probable caused alarm, string(64) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundSeverity | 1.3.6.1.4.1.2011.2.15.1.7.1.7 | ||
| Level of Alarm, string(64) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundEventDetail | 1.3.6.1.4.1.2011.2.15.1.7.1.8 | ||
| Alarm ID and detail information, format: ID+detail infomation, string(255) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| hwNmNorthboundAdditionalInfo | 1.3.6.1.4.1.2011.2.15.1.7.1.9 | ||
| Additional infomation of device, such as Country, City and so on, string(255) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| hwNmNorthboundFaultFlag | 1.3.6.1.4.1.2011.2.15.1.7.1.10 | ||
| The flag of the fault.Show whether the alarm is an event ,a fault alarm or a recovery alarm. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundFaultFunction | 1.3.6.1.4.1.2011.2.15.1.7.1.11 | ||
| The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Processerror','UNKNOWN_FUC_TYPE' | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundDeviceIP | 1.3.6.1.4.1.2011.2.15.1.7.1.12 | ||
| The IP address of the device | |||
| OBJECT-TYPE | |||
| IpAddress | |||
| hwNmNorthboundSerialNo | 1.3.6.1.4.1.2011.2.15.1.7.1.13 | ||
| The serial number of alarm. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| hwNmNorthboundProbableRepair | 1.3.6.1.4.1.2011.2.15.1.7.1.14 | ||
| The probable repair advice of the alarm. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..64) | ||
| hwNmNorthboundResourceIDs | 1.3.6.1.4.1.2011.2.15.1.7.1.15 | ||
| The ID of the resource. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB1 | 1.3.6.1.4.1.2011.2.15.1.7.1.16 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB2 | 1.3.6.1.4.1.2011.2.15.1.7.1.17 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB3 | 1.3.6.1.4.1.2011.2.15.1.7.1.18 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB4 | 1.3.6.1.4.1.2011.2.15.1.7.1.19 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB5 | 1.3.6.1.4.1.2011.2.15.1.7.1.20 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB6 | 1.3.6.1.4.1.2011.2.15.1.7.1.21 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB7 | 1.3.6.1.4.1.2011.2.15.1.7.1.22 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundsAdditionalVB8 | 1.3.6.1.4.1.2011.2.15.1.7.1.23 | ||
| Addtional information of the alarm | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundEventName | 1.3.6.1.4.1.2011.2.15.1.7.1.24 | ||
| The name of event,string (255) | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(1..255) | ||
| hwNmNorthboundEventKeepAliveInfo | 1.3.6.1.4.1.2011.2.15.1.7.2 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventKeepAlive | 1.3.6.1.4.1.2011.2.15.1.7.2.2 | ||
| Notification for keep alive traps. | |||
| TRAP-TYPE | |||
| hwNmNorthboundEventSynchronization | 1.3.6.1.4.1.2011.2.15.1.7.7 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventSynchronizationStart | 1.3.6.1.4.1.2011.2.15.1.7.7.1 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventSynchronizationStartNotify | 1.3.6.1.4.1.2011.2.15.1.7.7.1.9 | ||
| Notification indicates the beginning of alarm synchronization. | |||
| TRAP-TYPE | |||
| hwNmNorthboundEventSynchronizationQueryResult | 1.3.6.1.4.1.2011.2.15.1.7.7.2 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventSynchronizationEnd | 1.3.6.1.4.1.2011.2.15.1.7.7.3 | ||
| OBJECT IDENTIFIER | |||
| hwNmNorthboundEventSynchronizationEndStatus | 1.3.6.1.4.1.2011.2.15.1.7.7.3.1 | ||
| It shows the result of alarm synchronization. 1 means the alarm synchronization successfully ended. 2 means the alarm synchronization is stopped by the NMS's command. 3 means some error occured during the alarm synchronization. | |||
| OBJECT-TYPE | |||
| INTEGER | normalEnd(1), stopped(2), error(3) | ||
| hwNmNorthboundEventSynchronizationEndStatusDetail | 1.3.6.1.4.1.2011.2.15.1.7.7.3.2 | ||
| The detail description of the alarm synchronization end status. | |||
| OBJECT-TYPE | |||
| OCTET STRING | |||
| hwNmNorthboundEventSynchronizationEndNotify | 1.3.6.1.4.1.2011.2.15.1.7.7.3.11 | ||
| Notification indicates the end of alarm synchronization. | |||
| TRAP-TYPE | |||
| hwNmNorthboundEventSynchronizationEndStatus | |||
| hwNmNorthboundEventSynchronizationEndStatusDetail | |||
| hwNmNorthboundEventSynchronizationCommandStart | 1.3.6.1.4.1.2011.2.15.1.7.7.4 | ||
| This node is to be set to start the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will send alarm synchronization result to the IP and port specified. If there is already an running alarm synchronization for that IP and port,it will return a commit fail error. | |||
| OBJECT-TYPE | |||
| OCTET STRING | |||
| hwNmNorthboundEventSynchronizationCommandStop | 1.3.6.1.4.1.2011.2.15.1.7.7.5 | ||
| This node is to be set to stop the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will stop alarm synchronization for the IP and port specified. If there is no such an running alarm synchronization for that IP and port,it will return a commit fail error. | |||
| OBJECT-TYPE | |||
| OCTET STRING | |||