INTERFACES-MIB

File: INTERFACES-MIB.mib (126058 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB

Imported symbols

enterprises TimeTicks OBJECT-TYPE
DisplayString

Defined Objects

txport 1.3.6.1.4.1.425
OBJECT IDENTIFIER    

companyinfo 1.3.6.1.4.1.425.1
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.425.2
OBJECT IDENTIFIER    

temporary 1.3.6.1.4.1.425.3
OBJECT IDENTIFIER    

traps 1.3.6.1.4.1.425.4
OBJECT IDENTIFIER    

revision 1.3.6.1.4.1.425.5
OBJECT IDENTIFIER    

pdc 1.3.6.1.4.1.425.6
OBJECT IDENTIFIER    

utilities 1.3.6.1.4.1.425.7
OBJECT IDENTIFIER    

tinterfaces 1.3.6.1.4.1.425.8
OBJECT IDENTIFIER    

mgmtPorts 1.3.6.1.4.1.425.8.1
OBJECT IDENTIFIER    

mgmtPortsTable 1.3.6.1.4.1.425.8.1.1
The Management Ports table.
OBJECT-TYPE    
  SEQUENCE OF  
    MgmtPortsTableEntry

mgmtPortsTableEntry 1.3.6.1.4.1.425.8.1.1.1
An entry in the Management Ports table.
OBJECT-TYPE    
  MgmtPortsTableEntry  

mgmtPortsTableIndex 1.3.6.1.4.1.425.8.1.1.1.1
The index into the Management Ports table.
OBJECT-TYPE    
  INTEGER  

mgmtPortsDescription 1.3.6.1.4.1.425.8.1.1.1.2
Contains a textual description of the port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

mgmtPortsElementID 1.3.6.1.4.1.425.8.1.1.1.3
This object signifies the name of the device.
OBJECT-TYPE    
  DisplayString SIZE(0..27)  

mgmtPortsMode 1.3.6.1.4.1.425.8.1.1.1.4
This object signifies the method used by the port to report alarms.
OBJECT-TYPE    
  INTEGER other(1), disabled(2), coadial(3), coadirect(4), extAlarmOnOpen(5), extAlarmOnClosed(6), slipdial(7), slipdirect(8)  

mgmtPortsDialPrefix 1.3.6.1.4.1.425.8.1.1.1.5
This object contains the dial string prefix for a modem connected to the port.
OBJECT-TYPE    
  DisplayString SIZE(0..38)  

mgmtPortsPrimaryDialString 1.3.6.1.4.1.425.8.1.1.1.6
This object contains the primary dial string for a modem connected to the port.
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

mgmtPortsSecondaryDialString 1.3.6.1.4.1.425.8.1.1.1.7
This object contains the secondary dial string for a modem connected to the port.
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

mgmtPortsExtInitString 1.3.6.1.4.1.425.8.1.1.1.8
This object contains the init string for a modem connected to the port.
OBJECT-TYPE    
  DisplayString SIZE(0..38)  

mgmtPortsCompressedSlip 1.3.6.1.4.1.425.8.1.1.1.9
This object specifies if SLIP compression is to be used.
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3), auto(4)  

mgmtPortsInternalModem 1.3.6.1.4.1.425.8.1.1.1.10
This object signifies if the internal modem (when present) is enabled.
OBJECT-TYPE    
  INTEGER other(1), notPresent(2), enabled(3), disabled(4)  

dbu 1.3.6.1.4.1.425.8.2
OBJECT IDENTIFIER    

dbuConfigTable 1.3.6.1.4.1.425.8.2.1
The Dial Backup Configuration Table.
OBJECT-TYPE    
  SEQUENCE OF  
    DbuConfigTableEntry

dbuConfigTableEntry 1.3.6.1.4.1.425.8.2.1.1
An entry in the Dial Backup Configuration table.
OBJECT-TYPE    
  DbuConfigTableEntry  

dbuNearIndex 1.3.6.1.4.1.425.8.2.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

dbuFarIndex 1.3.6.1.4.1.425.8.2.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

dbuConfigTableIndex 1.3.6.1.4.1.425.8.2.1.1.3
The index into the Dial Backup table.
OBJECT-TYPE    
  INTEGER  

dbuDescription 1.3.6.1.4.1.425.8.2.1.1.4
Contains a textual description of the dbu.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

dbuRate 1.3.6.1.4.1.425.8.2.1.1.5
This object is the identifier of the current DDS DBU rate. The values mean: dbuRate2400 the DBU interface is operating at 2400bps dbuRate4800 the DBU interface is operating at 4800bps dbuRate9600 the DBU interface is operating at 9600bps dbuRate19200 the DBU interface is operating at 19200bps dbuRate38400 the DBU interface is operating at 38400bps dbuRate56000 the DBU interface is operating at 56000bps dbuRate57600 the DBU interface is operating at 57600bps dbuRate64000 the DBU interface is operating at 64000bps
OBJECT-TYPE    
  INTEGER dbuRateOther(1), dbuRate2400(2), dbuRate4800(3), dbuRate9600(4), dbuRate19200(5), dbuRate38400(6), dbuRate56000(7), dbuRate57600(8), dbuRate64000(9)  

dbuMode 1.3.6.1.4.1.425.8.2.1.1.6
This object is the identifier of the current mode that the Dial Backup Unit is operating in. The values mean: dbuModeOrig The dial backup unit is operating in the originate mode dbuModeAnsw The dial backup unit is operating in the answer mode dbuModeNotAvail The dial backup unit's mode is not available dbuModeCallbackOrig The dial backup unit is operating in the callback originate mode dbuModeCallbackAnsw The dial backup unit is operating in the callback mode dbuModeMaster The dial backup unit is configured as a master unit dbuModeSlave The dial backup unit is configured as a slave unit
OBJECT-TYPE    
  INTEGER dbuModeOther(1), dbuModeOrig(2), dbuModeAnsw(3), dbuModeNotAvail(4), dbuModeCallbackOrig(5), dbuModeCallbackAnsw(6), dbuModeMaster(7), dbuModeSlave(8)  

dbuFormat 1.3.6.1.4.1.425.8.2.1.1.7
This object is the identifier of the current format that the Dial Backup Unit is operating in. The values mean: dbuFormatSync The dial backup unit is operating in the synchronous format dbuFormatAsync The dial backup unit is operating in the asynchronous format dbuFormatNotAvail The dial backup unit's format is not available
OBJECT-TYPE    
  INTEGER dbuFormatOther(1), dbuFormatSync(2), dbuFormatAsync(3), dbuFormatNotAvail(4)  

dbuNumber 1.3.6.1.4.1.425.8.2.1.1.8
This string is the currently programmed number for the dial backup unit to call
OBJECT-TYPE    
  DisplayString SIZE(0..100)  

dbuStatus 1.3.6.1.4.1.425.8.2.1.1.9
This object is the identifier of the current Dial Backup Unit operating status. The values mean: dbuStatusDisabled The dial backup unit is either not installed or disabled dbuStatusEnabled The dial backup unit is installed and enabled dbuStatusActive The dial backup unit is currently active dbuStatusLocked The dial backup unit is in a locked state dbuStatusConnecting The dial backup unit is in the process of connecting dbuStatusDisallowed The dial backup unit is currently not allowed to activate due to the Time Of Day Enable settings dbuStatusAwaitingCall The dial backup unit is in the process of waiting for an incoming call dbuStatusDialing The dial backup unit is in the process of placing a call dbuStatusDisconnecting The dial backup unit is in the process of disconnecting dbuStatusTesting The dial backup unit is in the process of testing dbuStatusTestPassed The dial backup unit has passed a self-test dbuStatusTestFailed The dial backup unit has failed a self-test
OBJECT-TYPE    
  INTEGER dbuStatusOther(1), dbuStatusDisabled(2), dbuStatusEnabled(3), dbuStatusActive(4), dbuStatusLocked(5), dbuStatusConnecting(6), dbuStatusDisallowed(7), dbuStatusAwaitingCall(8), dbuStatusDialing(9), dbuStatusDisconnecting(10), dbuStatusTesting(11), dbuStatusTestPassed(12), dbuStatusTestFailed(13)  

dbuCommand 1.3.6.1.4.1.425.8.2.1.1.10
This object is the identifier of the current setting that the Dial Backup Unit is operating in. The values mean: dbuCommandDisable The dial backup unit is not to operate dbuCommandEnable The dial backup unit is to operate, subject to Activator and line conditions only dbuCommandActivate The dial backup unit is to operate, irregardless of line conditions dbuCommandLock The dial backup unit is to continue operating, irregardless of line conditions dbuCommandEnableDaily The dial backup unit is to operate, subject to Activator, line conditions, and the Time Of Day Enable fields dbuCommandTest The dial backup unit is commanded to test the link.
OBJECT-TYPE    
  INTEGER dbuCommandOther(1), dbuCommandDisable(2), dbuCommandEnable(3), dbuCommandActivate(4), dbuCommandLock(5), dbuCommandEnableDaily(6), dbuCommandTest(7)  

dbuActivator1 1.3.6.1.4.1.425.8.2.1.1.11
This object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activated by a LOS alarm condition dbuActivatorOOS The dial backup unit is activated by an OOS alarm condition dbuActivatorOOF The dial backup unit is activated by an OOF alarm condition dbuActivatorAny The dial backup unit is activated by a LOS, OOS, or OOF alarm condition dbuActivatorES The dial backup unit is activated by an ES alarm condition dbuActivatorSES The dial backup unit is activated by an SES alarm condition dbuActivatorUAS The dial backup unit is activated by an UAS alarm condition dbuActivatorLOF The dial backup unit is activated by an LOF alarm condition dbuActivatorRAS The dial backup unit is activated by an RAS alarm condition dbuActivatorAIS The dial backup unit is activated by an AIS alarm condition dbuActivatorBPV The dial backup unit is activated by an BPV alarm condition
OBJECT-TYPE    
  INTEGER dbuActivatorOther(1), dbuActivatorLOS(2), dbuActivatorOOS(3), dbuActivatorOOF(4), dbuActivatorAny(5), dbuActivatorES(6), dbuActivatorSES(7), dbuActivatorUAS(8), dbuActivatorLOF(9), dbuActivatorRAS(10), dbuActivatorAIS(11), dbuActivatorBPV(12)  

dbuActivator2 1.3.6.1.4.1.425.8.2.1.1.12
This object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activated by a LOS alarm condition dbuActivatorOOS The dial backup unit is activated by a OOS alarm condition dbuActivatorOOF The dial backup unit is activated by a OOF alarm condition dbuActivatorAny The dial backup unit is activated by a LOS, OOS, or OOF alarm condition dbuActivatorES The dial backup unit is activated by an ES alarm condition dbuActivatorSES The dial backup unit is activated by an SES alarm condition dbuActivatorUAS The dial backup unit is activated by an UAS alarm condition dbuActivatorLOF The dial backup unit is activated by an LOF alarm condition dbuActivatorRAS The dial backup unit is activated by an RAS alarm condition dbuActivatorAIS The dial backup unit is activated by an AIS alarm condition dbuActivatorBPV The dial backup unit is activated by an BPV alarm condition
OBJECT-TYPE    
  INTEGER dbuActivatorOther(1), dbuActivatorLOS(2), dbuActivatorOOS(3), dbuActivatorOOF(4), dbuActivatorAny(5), dbuActivatorES(6), dbuActivatorSES(7), dbuActivatorUAS(8), dbuActivatorLOF(9), dbuActivatorRAS(10), dbuActivatorAIS(11), dbuActivatorBPV(12)  

dbuDialStr 1.3.6.1.4.1.425.8.2.1.1.13
This string is the dial string sent to the dial backup unit during every connection attempt
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

dbuInitStr 1.3.6.1.4.1.425.8.2.1.1.14
This string is the initialization string sent to the dial backup unit before every connection attempt
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

dbuHangupStr 1.3.6.1.4.1.425.8.2.1.1.15
This string is the hangup command string sent to the dial backup unit after every successful call
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

dbuPasswordStr 1.3.6.1.4.1.425.8.2.1.1.16
This string is the prompt character and password string for the dial backup unit in Callback DBU
OBJECT-TYPE    
  DisplayString SIZE(0..8)  

dbuSecurity 1.3.6.1.4.1.425.8.2.1.1.17
Enables security on dial backup unit.
OBJECT-TYPE    
  INTEGER dbuSecurityOther(1), dbuSecurityDisable(2), dbuSecurityEnable(3)  

dbuDtrDial 1.3.6.1.4.1.425.8.2.1.1.18
Enables DTR dial feature on dial backup unit.
OBJECT-TYPE    
  INTEGER dbuDtrDialOther(1), dbuDtrDialDisable(2), dbuDtrDialEnable(3)  

dbuISDNSwitchType 1.3.6.1.4.1.425.8.2.1.1.19
Specifies the switch type for the ISDN DBU.
OBJECT-TYPE    
  INTEGER  

dbuISDNSwitchVersion 1.3.6.1.4.1.425.8.2.1.1.20
Specifies the switch version for the ISDN DBU.
OBJECT-TYPE    
  INTEGER dbuISDNSwitchVersionOther(1), dbuISDNSwitchVersionNational1(2), dbuISDNSwitchVersionATTP2P(3), dbuISDNSwitchVersionATTMP(4), dbuISDNSwitchVersionDMS100PVCIC0(5), dbuISDNSwitchVersionDMS100PVCIC1(6)  

dbuISDNTEI 1.3.6.1.4.1.425.8.2.1.1.21
Specifies the ISDN DBU TEI.
OBJECT-TYPE    
  INTEGER dbuISDNTEIOther(1), dbuISDNTEIDisable(2), dbuISDNTEIAuto(3), dbuISDNTEI0(4), dbuISDNTEI1(5), dbuISDNTEI2(6), dbuISDNTEI3(7), dbuISDNTEI4(8), dbuISDNTEI5(9), dbuISDNTEI6(10), dbuISDNTEI7(11), dbuISDNTEI8(12), dbuISDNTEI9(13), dbuISDNTEI10(14), dbuISDNTEI11(15), dbuISDNTEI12(16), dbuISDNTEI13(17), dbuISDNTEI14(18), dbuISDNTEI15(19), dbuISDNTEI16(20), dbuISDNTEI17(21), dbuISDNTEI18(22), dbuISDNTEI19(23), dbuISDNTEI20(24), dbuISDNTEI21(25), dbuISDNTEI22(26), dbuISDNTEI23(27), dbuISDNTEI24(28), dbuISDNTEI25(29), dbuISDNTEI26(30), dbuISDNTEI27(31), dbuISDNTEI28(32), dbuISDNTEI29(33), dbuISDNTEI30(34), dbuISDNTEI31(35), dbuISDNTEI32(36), dbuISDNTEI33(37), dbuISDNTEI34(38), dbuISDNTEI35(39), dbuISDNTEI36(40), dbuISDNTEI37(41), dbuISDNTEI38(42), dbuISDNTEI39(43), dbuISDNTEI40(44), dbuISDNTEI41(45), dbuISDNTEI42(46), dbuISDNTEI43(47), dbuISDNTEI44(48), dbuISDNTEI45(49), dbuISDNTEI46(50), dbuISDNTEI47(51), dbuISDNTEI48(52), dbuISDNTEI49(53), dbuISDNTEI50(54), dbuISDNTEI51(55), dbuISDNTEI52(56), dbuISDNTEI53(57), dbuISDNTEI54(58), dbuISDNTEI55(59), dbuISDNTEI56(60), dbuISDNTEI57(61), dbuISDNTEI58(62), dbuISDNTEI59(63), dbuISDNTEI60(64), dbuISDNTEI61(65), dbuISDNTEI62(66), dbuISDNTEI63(67)  

dbuISDNSPID 1.3.6.1.4.1.425.8.2.1.1.22
Specifies the SPID for the ISDN DBU.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

dbuISDNDDNUM 1.3.6.1.4.1.425.8.2.1.1.23
Specifies the Data Directory Number for the ISDN DBU.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

dbuResetStringsTable 1.3.6.1.4.1.425.8.2.2
A table of COLD START reprogramming strings for the dial backup unit.
OBJECT-TYPE    
  SEQUENCE OF  
    DbuResetStringsEntry

dbuResetStringsEntry 1.3.6.1.4.1.425.8.2.2.1
An entry in the dbuResetStringsTable.
OBJECT-TYPE    
  DbuResetStringsEntry  

dbuResetNearIndex 1.3.6.1.4.1.425.8.2.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

dbuResetFarIndex 1.3.6.1.4.1.425.8.2.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

dbuResetConfigEntryIndex 1.3.6.1.4.1.425.8.2.2.1.3
The index into the Dial Backup table.
OBJECT-TYPE    
  INTEGER  

dbuResetStringsIndex 1.3.6.1.4.1.425.8.2.2.1.4
The index into the dbuResetStringsTable.
OBJECT-TYPE    
  INTEGER  

dbuResetString 1.3.6.1.4.1.425.8.2.2.1.5
This string is one of the dial backup unit's COLD START reprogramming strings
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

dbuStartStopTable 1.3.6.1.4.1.425.8.2.3
The Dial Backup StartStop Table.
OBJECT-TYPE    
  SEQUENCE OF  
    DbuStartStopTableEntry

dbuStartStopTableEntry 1.3.6.1.4.1.425.8.2.3.1
An entry in the Dial Backup Start Stop table.
OBJECT-TYPE    
  DbuStartStopTableEntry  

dbuStartStopNearIndex 1.3.6.1.4.1.425.8.2.3.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

dbuStartStopFarIndex 1.3.6.1.4.1.425.8.2.3.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

dbuStartStopConfigEntryIndex 1.3.6.1.4.1.425.8.2.3.1.3
The index into the Dial Backup table.
OBJECT-TYPE    
  INTEGER  

dbuStartStopDayOfWeek 1.3.6.1.4.1.425.8.2.3.1.4
The index into the Dial Backup Start Stop times table.
OBJECT-TYPE    
  INTEGER dbuStartStopSunday(1), dbuStartStopMonday(2), dbuStartStopTuesday(3), dbuStartStopWednesday(4), dbuStartStopThursday(5), dbuStartStopFriday(6), dbuStartStopSaturday(7)  

dbuStart 1.3.6.1.4.1.425.8.2.3.1.5
This object is the beginning of an allowable window for Dial Backup Activation.
OBJECT-TYPE    
  INTEGER dbuStartHour00(1), dbuStartHour01(2), dbuStartHour02(3), dbuStartHour03(4), dbuStartHour04(5), dbuStartHour05(6), dbuStartHour06(7), dbuStartHour07(8), dbuStartHour08(9), dbuStartHour09(10), dbuStartHour10(11), dbuStartHour11(12), dbuStartHour12(13), dbuStartHour13(14), dbuStartHour14(15), dbuStartHour15(16), dbuStartHour16(17), dbuStartHour17(18), dbuStartHour18(19), dbuStartHour19(20), dbuStartHour20(21), dbuStartHour21(22), dbuStartHour22(23), dbuStartHour23(24)  

dbuStop 1.3.6.1.4.1.425.8.2.3.1.6
This object is the end of an allowable window for Dial Backup Activation.
OBJECT-TYPE    
  INTEGER dbuStopHour00(1), dbuStopHour01(2), dbuStopHour02(3), dbuStopHour03(4), dbuStopHour04(5), dbuStopHour05(6), dbuStopHour06(7), dbuStopHour07(8), dbuStopHour08(9), dbuStopHour09(10), dbuStopHour10(11), dbuStopHour11(12), dbuStopHour12(13), dbuStopHour13(14), dbuStopHour14(15), dbuStopHour15(16), dbuStopHour16(17), dbuStopHour17(18), dbuStopHour18(19), dbuStopHour19(20), dbuStopHour20(21), dbuStopHour21(22), dbuStopHour22(23), dbuStopHour23(24)  

t1e1 1.3.6.1.4.1.425.8.3
OBJECT IDENTIFIER    

t1e1ConfigTable 1.3.6.1.4.1.425.8.3.1
The T1 and E1 Configuration Table.
OBJECT-TYPE    
  SEQUENCE OF  
    T1e1ConfigTableEntry

t1e1ConfigTableEntry 1.3.6.1.4.1.425.8.3.1.1
An entry in the t1e1Table.
OBJECT-TYPE    
  T1e1ConfigTableEntry  

t1e1ConfigNearIndex 1.3.6.1.4.1.425.8.3.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

t1e1ConfigFarIndex 1.3.6.1.4.1.425.8.3.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

t1e1ConfigIndex 1.3.6.1.4.1.425.8.3.1.1.3
This object is the index into the t1e1Table.
OBJECT-TYPE    
  INTEGER  

t1e1Description 1.3.6.1.4.1.425.8.3.1.1.4
Contains a textual description of the port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

t1e1Mode 1.3.6.1.4.1.425.8.3.1.1.5
This object identifies the port as either a Network (long-haul) or DTE (short-haul) port.
OBJECT-TYPE    
  INTEGER t1e1ModeOther(1), t1e1ModeDTE(2), t1e1ModeNetwork(3)  

t1e1FrameType 1.3.6.1.4.1.425.8.3.1.1.6
Selects the framing for the network side of the DSU/CSU.
OBJECT-TYPE    
  INTEGER t1e1FrameTypeOther(1), t1e1FrameTypeESF(2), t1e1FrameTypeD4(3), t1e1FrameTypeCCSCRC(4), t1e1FrameTypeCCS(5), t1e1FrameTypeCAS(6), t1e1FrameTypeCASCRC(7), t1e1FrameTypeUnframed(8)  

t1e1LineCode 1.3.6.1.4.1.425.8.3.1.1.7
Selects the network side line coding.
OBJECT-TYPE    
  INTEGER t1e1LineCodeOther(1), t1e1LineCodeAMI(2), t1e1LineCodeB8ZS(3), t1e1LineCodeHDB3(4)  

t1e1LineBuildOut 1.3.6.1.4.1.425.8.3.1.1.8
Selects the line build out for the network interface. The options are: t1e1LineBuildOut0db indicates a line build out of 0db t1e1LineBuildOut75db indicates a line build out of -7.5db t1e1LineBuildOut15db indicates a line build out of -15db t1e1LineBuildOut225db indicates a line build out of -22.5db
OBJECT-TYPE    
  INTEGER t1e1LineBuildOutOther(1), t1e1LineBuildOut0db(2), t1e1LineBuildOut75db(3), t1e1LineBuildOut15db(4), t1e1LineBuildOut225db(5)  

t1e1Timing 1.3.6.1.4.1.425.8.3.1.1.9
Sets the timing source to synchronize the unit's internal timing generators.
OBJECT-TYPE    
  INTEGER t1e1TimingOther(1), t1e1TimingInternal(2), t1e1TimingNetwork(3), t1e1TimingT1DTE(4), t1e1TimingStation(5), t1e1TimingStaClock(6), t1e1TimingPort1(7), t1e1TimingPort2(8), t1e1TimingPort3(9), t1e1TimingPort4(10), t1e1TimingPort5(11), t1e1TimingPort6(12), t1e1TimingPort7(13), t1e1TimingPort8(14), t1e1TimingPort9(15), t1e1TimingPort10(16), t1e1TimingPort11(17), t1e1TimingPort12(18), t1e1TimingPort13(19), t1e1TimingPort14(20), t1e1TimingPort15(21), t1e1TimingPort16(22), t1e1TimingPort17(23), t1e1TimingPort18(24), t1e1TimingPort19(25), t1e1TimingPort20(26), t1e1TimingPort21(27), t1e1TimingPort22(28), t1e1TimingPort23(29), t1e1TimingPort24(30), t1e1TimingPort25(31), t1e1TimingPort26(32), t1e1TimingPort27(33), t1e1TimingPort28(34), t1e1TimingPort29(35), t1e1TimingPort30(36), t1e1TimingPort31(37), t1e1TimingPort32(38), t1e1TimingSlot2PortA(39), t1e1TimingSlot2PortB(40), t1e1TimingSlot3PortA(41), t1e1TimingSlot3PortB(42), t1e1TimingSlot4PortA(43), t1e1TimingSlot4PortB(44), t1e1TimingSlot5PortA(45), t1e1TimingSlot5PortB(46), t1e1TimingSlot6PortA(47), t1e1TimingSlot6PortB(48), t1e1TimingSlot2Dsu1PortA(49), t1e1TimingSlot2Dsu1PortB(50), t1e1TimingSlot2Dsu2PortA(51), t1e1TimingSlot2Dsu2PortB(52), t1e1TimingSlot2Dsu3PortA(53), t1e1TimingSlot2Dsu3PortB(54), t1e1TimingSlot2Dsu4PortA(55), t1e1TimingSlot2Dsu4PortB(56), t1e1TimingSlot2Dsu5PortA(57), t1e1TimingSlot2Dsu5PortB(58), t1e1TimingSlot2Dsu6PortA(59), t1e1TimingSlot2Dsu6PortB(60), t1e1TimingSlot3Dsu1PortA(61), t1e1TimingSlot3Dsu1PortB(62), t1e1TimingSlot3Dsu2PortA(63), t1e1TimingSlot3Dsu2PortB(64), t1e1TimingSlot3Dsu3PortA(65), t1e1TimingSlot3Dsu3PortB(66), t1e1TimingSlot3Dsu4PortA(67), t1e1TimingSlot3Dsu4PortB(68), t1e1TimingSlot3Dsu5PortA(69), t1e1TimingSlot3Dsu5PortB(70), t1e1TimingSlot3Dsu6PortA(71), t1e1TimingSlot3Dsu6PortB(72), t1e1TimingSlot4Dsu1PortA(73), t1e1TimingSlot4Dsu1PortB(74), t1e1TimingSlot4Dsu2PortA(75), t1e1TimingSlot4Dsu2PortB(76), t1e1TimingSlot4Dsu3PortA(77), t1e1TimingSlot4Dsu3PortB(78), t1e1TimingSlot4Dsu4PortA(79), t1e1TimingSlot4Dsu4PortB(80), t1e1TimingSlot4Dsu5PortA(81), t1e1TimingSlot4Dsu5PortB(82), t1e1TimingSlot4Dsu6PortA(83), t1e1TimingSlot4Dsu6PortB(84), t1e1TimingSlot5Dsu1PortA(85), t1e1TimingSlot5Dsu1PortB(86), t1e1TimingSlot5Dsu2PortA(87), t1e1TimingSlot5Dsu2PortB(88), t1e1TimingSlot5Dsu3PortA(89), t1e1TimingSlot5Dsu3PortB(90), t1e1TimingSlot5Dsu4PortA(91), t1e1TimingSlot5Dsu4PortB(92), t1e1TimingSlot5Dsu5PortA(93), t1e1TimingSlot5Dsu5PortB(94), t1e1TimingSlot5Dsu6PortA(95), t1e1TimingSlot5Dsu6PortB(96), t1e1TimingSlot6Dsu1PortA(97), t1e1TimingSlot6Dsu1PortB(98), t1e1TimingSlot6Dsu2PortA(99), t1e1TimingSlot6Dsu2PortB(100), t1e1TimingSlot6Dsu3PortA(101), t1e1TimingSlot6Dsu3PortB(102), t1e1TimingSlot6Dsu4PortA(103), t1e1TimingSlot6Dsu4PortB(104), t1e1TimingSlot6Dsu5PortA(105), t1e1TimingSlot6Dsu5PortB(106), t1e1TimingSlot6Dsu6PortA(107), t1e1TimingSlot6Dsu6PortB(108)  

t1e1StationInTiming 1.3.6.1.4.1.425.8.3.1.1.10
Selects the input timing if t1e1Timing is set to Station.
OBJECT-TYPE    
  INTEGER t1e1StationInTimingOther(1), t1e1StationInTimingNX56(2), t1e1StationInTimingNX64(3), t1e1StationInTiming1544(4), t1e1StationInTiming2048(5)  

t1e1StationTiming 1.3.6.1.4.1.425.8.3.1.1.11
Selects the N-multiple when Station Input Timing is set to either NX56 or NX65. The N range is 1..24
OBJECT-TYPE    
  INTEGER  

t1e1PRM 1.3.6.1.4.1.425.8.3.1.1.12
Enables the ANSI T1.403 Performance Report Message functions.
OBJECT-TYPE    
  INTEGER t1e1PRMOther(1), t1e1PRMDisable(2), t1e1PRMEnable(3)  

t1e1ZeroSuppress 1.3.6.1.4.1.425.8.3.1.1.13
Determines whether ones density insertion is activated after 15 zeros . To ensure compliance with TR54016, this field must be enabled.
OBJECT-TYPE    
  INTEGER t1e1ZeroOther(1), t1e1ZeroDisable(2), t1e1ZeroEnable(3)  

t1e1NationalBit 1.3.6.1.4.1.425.8.3.1.1.14
Selects a national bit to create a 4-kpbs datalink between the endpoint units.
OBJECT-TYPE    
  INTEGER t1e1NationalOther(1), t1e1NationalNone(2), t1e1NationalSA4(3), t1e1NationalSA5(4), t1e1NationalSA6(5), t1e1NationalSA7(6), t1e1NationalSA8(7)  

t1e1KeepAlive 1.3.6.1.4.1.425.8.3.1.1.15
Selects keep alive framed and unframed ones when the unit detects LOS or OOF.
OBJECT-TYPE    
  INTEGER t1e1KeepAliveOther(1), t1e1KeepAliveUnframedOnes(2), t1e1KeepAliveFramedOnes(3), t1e1KeepAliveLoop(4)  

t1e1CRC4Mode 1.3.6.1.4.1.425.8.3.1.1.16
Selects whether CRC4 is enabled or disabled.
OBJECT-TYPE    
  INTEGER t1e1CRC4Other(1), t1e1CRC4Disabled(2), t1e1CRC4Enabled(3)  

t1e1DSXLevel 1.3.6.1.4.1.425.8.3.1.1.17
Selects the DSX1 interface output level.
OBJECT-TYPE    
  INTEGER t1e1DSXOther(1), t1e1DSX0110(2), t1e1DSX111220(3), t1e1DSX221330(4), t1e1DSX331440(5), t1e1DSX441550(6), t1e1DSX551660(7), t1e1DSX661up(8)  

t1e1CRC 1.3.6.1.4.1.425.8.3.1.1.18
Determines whether received CRC data is passed through or regenerated.
OBJECT-TYPE    
  INTEGER t1e1CRCOther(1), t1e1CRCPass(2), t1e1CRCRegenerate(3)  

t1e1FDLPassThrough 1.3.6.1.4.1.425.8.3.1.1.19
Determines whether the ESF FDL passes through the CSU or terminates.
OBJECT-TYPE    
  INTEGER t1e1FDLPassThroughOther(1), t1e1FDLPassThroughPass(2), t1e1FDLPassThroughTerminate(3)  

t1e1AudibleAlarm 1.3.6.1.4.1.425.8.3.1.1.20
If applicable, Enables or Disables the CSU's internal buzzer which alerts users of an alarm condition.
OBJECT-TYPE    
  INTEGER t1e1AudibleAlarmOther(1), t1e1AudibleAlarmDisabled(2), t1e1AudibleAlarmEnabled(3)  

t1e1AlarmTable 1.3.6.1.4.1.425.8.3.2
The T1 and E1 Alarm Table.
OBJECT-TYPE    
  SEQUENCE OF  
    T1e1AlarmTableEntry

t1e1AlarmTableEntry 1.3.6.1.4.1.425.8.3.2.1
An entry in the t1e1Table.
OBJECT-TYPE    
  T1e1AlarmTableEntry  

t1e1AlarmNearIndex 1.3.6.1.4.1.425.8.3.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

t1e1AlarmFarIndex 1.3.6.1.4.1.425.8.3.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

t1e1AlarmIndex 1.3.6.1.4.1.425.8.3.2.1.3
This object is the index into the t1e1Table.
OBJECT-TYPE    
  INTEGER  

t1e1StatusSummary 1.3.6.1.4.1.425.8.3.2.1.4
This object provides a summary of the port status.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

t1e1AlarmSummary 1.3.6.1.4.1.425.8.3.2.1.5
This object provides a summary of the port alarms.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

t1e1ESStatus 1.3.6.1.4.1.425.8.3.2.1.6
Reports if a Errorred Seconds condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoES(2), t1e1StatusES(3)  

t1e1ESCount 1.3.6.1.4.1.425.8.3.2.1.7
This count contains the number of consecutive seconds an Errored Seconds condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1ESThreshold 1.3.6.1.4.1.425.8.3.2.1.8
Sets the Errored Seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1ESAlarm 1.3.6.1.4.1.425.8.3.2.1.9
This status indicates if the Errors Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1ESAlarmOther(1), t1e1ESAlarmNone(2), t1e1ESAlarmThresholdExceeded(3)  

t1e1SESStatus 1.3.6.1.4.1.425.8.3.2.1.10
Reports if a Severely Errorred condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoSES(2), t1e1StatusSES(3)  

t1e1SESCount 1.3.6.1.4.1.425.8.3.2.1.11
This count contains the number of consecutive seconds a Severely Errored condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1SESThreshold 1.3.6.1.4.1.425.8.3.2.1.12
Sets the Severely Errored seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1SESAlarm 1.3.6.1.4.1.425.8.3.2.1.13
This status indicates if the Severely Errors Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1SESAlarmOther(1), t1e1SESAlarmNone(2), t1e1SESAlarmThresholdExceeded(3)  

t1e1LOSSStatus 1.3.6.1.4.1.425.8.3.2.1.14
Reports if a Loss of Signal condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoLOSS(2), t1e1StatusLOSS(3)  

t1e1LOSSCount 1.3.6.1.4.1.425.8.3.2.1.15
This count contains the number of consecutive seconds a Loss of Signal condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1LOSSThreshold 1.3.6.1.4.1.425.8.3.2.1.16
Sets the Loss of Signal seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1LOSSAlarm 1.3.6.1.4.1.425.8.3.2.1.17
This status indicates if the Loss of Signal Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1LOSSAlarmOther(1), t1e1LOSSAlarmNone(2), t1e1LOSSAlarmThresholdExceeded(3)  

t1e1UASStatus 1.3.6.1.4.1.425.8.3.2.1.18
Reports if an Unavailable condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoUAS(2), t1e1StatusUAS(3)  

t1e1UASCount 1.3.6.1.4.1.425.8.3.2.1.19
This count contains the number of consecutive seconds an Unavailable condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1UASThreshold 1.3.6.1.4.1.425.8.3.2.1.20
Sets the unavailable seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1UASAlarm 1.3.6.1.4.1.425.8.3.2.1.21
This status indicates if the Unavailable Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1UASAlarmOther(1), t1e1UASAlarmNone(2), t1e1UASAlarmThresholdExceeded(3)  

t1e1CSSStatus 1.3.6.1.4.1.425.8.3.2.1.22
Reports if a Controlled Slip condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoCSS(2), t1e1StatusCSS(3)  

t1e1CSSCount 1.3.6.1.4.1.425.8.3.2.1.23
This count contains the number of consecutive seconds in which at least one Controlled Slip occurred.
OBJECT-TYPE    
  INTEGER  

t1e1CSSThreshold 1.3.6.1.4.1.425.8.3.2.1.24
Sets the Controlled Slip seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1CSSAlarm 1.3.6.1.4.1.425.8.3.2.1.25
This status indicates if the Controlled Slip seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1CSSAlarmOther(1), t1e1CSSAlarmNone(2), t1e1CSSAlarmThresholdExceeded(3)  

t1e1BPVSStatus 1.3.6.1.4.1.425.8.3.2.1.26
Reports if a Bipolar Violation Error condition exists.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoBPVS(2), t1e1StatusBPVS(3)  

t1e1BPVSCount 1.3.6.1.4.1.425.8.3.2.1.27
This count contains the number of consecutive seconds a Bipolar Violation Error condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1BPVSThreshold 1.3.6.1.4.1.425.8.3.2.1.28
Sets the Bipolar Violation Error seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1BPVSAlarm 1.3.6.1.4.1.425.8.3.2.1.29
This status indicates if the Bipolar Violation Error seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER t1e1BPVSAlarmOther(1), t1e1BPVSAlarmNone(2), t1e1BPVSAlarmThresholdExceeded(3)  

t1e1OOFSStatus 1.3.6.1.4.1.425.8.3.2.1.30
Indicates that the unit is unable to synchronize on the incoming framing pattern.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoOOF(2), t1e1StatusOOF(3)  

t1e1OOFSCount 1.3.6.1.4.1.425.8.3.2.1.31
This count contains the number of consecutive seconds an OOF condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1OOFSThreshold 1.3.6.1.4.1.425.8.3.2.1.32
Sets the OOF seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1OOFSAlarm 1.3.6.1.4.1.425.8.3.2.1.33
Indicates if an OOF seconds alarm condition exists.
OBJECT-TYPE    
  INTEGER t1e1OOFSAlarmOther(1), t1e1OOFSAlarmNone(2), t1e1OOFSAlarmExists(3)  

t1e1AISStatus 1.3.6.1.4.1.425.8.3.2.1.34
Indicates that the unit is receiving an unframed all ones pattern.
OBJECT-TYPE    
  INTEGER t1e1StatusOther(1), t1e1StatusNoAIS(2), t1e1StatusAIS(3)  

t1e1AISCount 1.3.6.1.4.1.425.8.3.2.1.35
This count contains the number of consecutive seconds an Unframed All Ones condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1AISThreshold 1.3.6.1.4.1.425.8.3.2.1.36
Sets the AIS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1AISAlarm 1.3.6.1.4.1.425.8.3.2.1.37
Indicates if an Unframed All Ones alarm condition exists.
OBJECT-TYPE    
  INTEGER t1e1AISAlarmOther(1), t1e1AISAlarmNone(2), t1e1AISAlarmExists(3)  

t1e1RASStatus 1.3.6.1.4.1.425.8.3.2.1.38
Reports if a Remote (Yellow) Alarm condition exists.
OBJECT-TYPE    
  INTEGER t1e1RASStatusOther(1), t1e1RASStatusNoRAS(2), t1e1RASStatusRAS(3)  

t1e1RASCount 1.3.6.1.4.1.425.8.3.2.1.39
This count contains the number of consecutive seconds a Remote (Yellow) Alarm condition has existed.
OBJECT-TYPE    
  INTEGER  

t1e1RASThreshold 1.3.6.1.4.1.425.8.3.2.1.40
Sets the RAS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1RASAlarm 1.3.6.1.4.1.425.8.3.2.1.41
This status indicates if a Remote (Yellow) Alarm exists.
OBJECT-TYPE    
  INTEGER t1e1RASAlarmOther(1), t1e1RASAlarmNone(2), t1e1RASAlarmExists(3)  

t1e1AlarmResetTimer 1.3.6.1.4.1.425.8.3.2.1.42
Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

t1e1AlarmReset 1.3.6.1.4.1.425.8.3.2.1.43
This is used to clear the current alarm counts.
OBJECT-TYPE    
  INTEGER t1e1AlarmResetOther(1), t1e1AlarmResetClearAlarms(2)  

ddsNet 1.3.6.1.4.1.425.8.4
OBJECT IDENTIFIER    

ddsNetConfigTable 1.3.6.1.4.1.425.8.4.1
The dds Network Interface Configuration Table.
OBJECT-TYPE    
  SEQUENCE OF  
    DdsNetConfigTableEntry

ddsNetConfigTableEntry 1.3.6.1.4.1.425.8.4.1.1
An entry in the Network Interface Table.
OBJECT-TYPE    
  DdsNetConfigTableEntry  

ddsNetConfigNearIndex 1.3.6.1.4.1.425.8.4.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

ddsNetConfigFarIndex 1.3.6.1.4.1.425.8.4.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

ddsNetConfigIndex 1.3.6.1.4.1.425.8.4.1.1.3
Index into the ddsNetConfigTable.
OBJECT-TYPE    
  INTEGER  

ddsNetDescription 1.3.6.1.4.1.425.8.4.1.1.4
Contains a textual description of the port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

ddsNetRate 1.3.6.1.4.1.425.8.4.1.1.5
This object is the identifier of the current DDS network rate. The values mean: ddsNetRate2400 the DDS network interface is operating at 2400bps ddsNetRate4800 the DDS network interface is operating at 4800bps ddsNetRate9600 the DDS network interface is operating at 9600bps ddsNetRate19200 the DDS network interface is operating at 19200bps ddsNetRate38400 the DDS network interface is operating at 38400bps ddsNetRate56000 the DDS network interface is operating at 56000bps ddsNetRate64000 the DDS network interface is operating at 64000bps
OBJECT-TYPE    
  INTEGER ddsNetRate2400(1), ddsNetRate4800(2), ddsNetRate9600(3), ddsNetRate19200(4), ddsNetRate38400(5), ddsNetRate56000(6), ddsNetRate64000(7)  

ddsNetMode 1.3.6.1.4.1.425.8.4.1.1.6
This variable describes mode in which data is being sent from the DDS unit back towards the network. Changing the value of this variable can cause a loss of remote communications. The values mean: ddsNetModeNormal (DDS-I) normal data mode of operation ddsNetModeProprietaryTXPI (DDS-I) data being sent out on the DDS network is in a proprietary mode to allow for remote communications, rate adaption, and SYNC to ASYNC modes ddsNetMode64KClearChannel (DDS-II) A special case of DDS-II, where the line rate is 72K, the data rate is 64K, and there is no secondary channel. ddsNetMode64KCCProprietaryTXPII (DDS-II) A special case of DDS-II, where the line rate is 72K, the data rate is 64K, and there is no secondary channel. In addition, the data being sent out on the DDS network is in a proprietary mode to allow for remote communications, rate adaption, SYNC to ASYNC, and/or TDM modes.
OBJECT-TYPE    
  INTEGER ddsNetModeNormal(1), ddsNetModeProprietaryTXPI(2), ddsNetMode64KClearChannel(3), ddsNetMode64KCCProprietaryTXPII(4)  

ddsNetTimingSource 1.3.6.1.4.1.425.8.4.1.1.7
This variable describes the current timing source for the DDS network interface. The values mean: ddsNetTimingNet unit dependant upon network for DDS network interface timing ddsNetTimingInt unit supplying timing for DDS network interface ddsNetTimingDTE unit dependant upon DTE device for network interface timing
OBJECT-TYPE    
  INTEGER ddsNetTimingNet(1), ddsNetTimingInt(2), ddsNetTimingDTE(3)  

ddsNetRemComm 1.3.6.1.4.1.425.8.4.1.1.8
This variable describes the current setting for the remote communications link. The values mean: ddsNetRemCommEnabled remote communications can be carried out end to end ddsNetRemCommDisabled remote communications are not allowed ddsNetRemCommNotAvailable this unit does not support remote communications
OBJECT-TYPE    
  INTEGER ddsNetRemCommEnabled(1), ddsNetRemCommDisabled(2), ddsNetRemCommNotAvailable(3)  

ddsNetCircuitAssur 1.3.6.1.4.1.425.8.4.1.1.9
This variable describes the current setting for the circuit assurance option. The values mean: ddsNetCircuitAssurEnabled Circuit Assurance is enabled and the integrity of the DDS loop will be maintained ddsNetCircuitAssurDisabled Circuit Assurance is disabled ddsNetCircuitAssurNotAvailable this unit does not support Circuit Assurance
OBJECT-TYPE    
  INTEGER ddsNetCircuitAssurEnabled(1), ddsNetCircuitAssurDisabled(2), ddsNetCircuitAssurNotAvailable(3)  

ddsNetAntiStrTimer 1.3.6.1.4.1.425.8.4.1.1.10
This variable describes the current setting for the anti streaming timer. The values mean: ddsNetAntiStrTimerOff the AntiStreaming Timer is off ddsNetAntiStrTimer10 the AntiStreaming Timer is set to 10 seconds ddsNetAntiStrTimer30 the AntiStreaming Timer is set to 30 seconds ddsNetAntiStrTimer60 ths AntiStreaming Timer is set to 60 seconds
OBJECT-TYPE    
  INTEGER ddsNetAntiStrTimerOff(1), ddsNetAntiStrTimer10(2), ddsNetAntiStrTimer30(3), ddsNetAntiStrTimer60(4)  

ddsNetAlarmTable 1.3.6.1.4.1.425.8.4.2
The dds Network Interface Alarm Table.
OBJECT-TYPE    
  SEQUENCE OF  
    DdsNetAlarmTableEntry

ddsNetAlarmTableEntry 1.3.6.1.4.1.425.8.4.2.1
An entry in the ddsNetAlarmTable.
OBJECT-TYPE    
  DdsNetAlarmTableEntry  

ddsNetAlarmNearIndex 1.3.6.1.4.1.425.8.4.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

ddsNetAlarmFarIndex 1.3.6.1.4.1.425.8.4.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

ddsNetAlarmIndex 1.3.6.1.4.1.425.8.4.2.1.3
Index into the ddsNetAlarmTable.
OBJECT-TYPE    
  INTEGER  

ddsNetStatusSummary 1.3.6.1.4.1.425.8.4.2.1.4
This object provides a summary of the port status.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

ddsNetAlarmSummary 1.3.6.1.4.1.425.8.4.2.1.5
This object provides a summary of the port alarms.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

ddsNetLOSStatus 1.3.6.1.4.1.425.8.4.2.1.6
Reports if a Loss of Signal condition exists.
OBJECT-TYPE    
  INTEGER ddsNetStatusLOSOther(1), ddsNetStatusNoLOS(2), ddsNetStatusLOS(3)  

ddsNetLOSCount 1.3.6.1.4.1.425.8.4.2.1.7
This count contains the number of consecutive seconds the unit received signal has been interrupted.
OBJECT-TYPE    
  INTEGER  

ddsNetLOSThreshold 1.3.6.1.4.1.425.8.4.2.1.8
A period, measured in seconds, in which the DDS received signal is interrupted.
OBJECT-TYPE    
  INTEGER ddsNetLOSThresholdOther(1), ddsNetLOSThresholdNone(2), ddsNetLOSThreshold1(3), ddsNetLOSThreshold2(4), ddsNetLOSThreshold3(5), ddsNetLOSThreshold4(6), ddsNetLOSThreshold5(7), ddsNetLOSThreshold10(8), ddsNetLOSThreshold20(9), ddsNetLOSThreshold30(10)  

ddsNetLOSAlarm 1.3.6.1.4.1.425.8.4.2.1.9
This status indicates if the Loss of Signal Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER ddsNetLOSAlarmOther(1), ddsNetLOSAlarmNone(2), ddsNetLOSAlarmThresholdExceeded(3)  

ddsNetOOFStatus 1.3.6.1.4.1.425.8.4.2.1.10
Reports if an Out of Frame condition exists.
OBJECT-TYPE    
  INTEGER ddsNetStatusOOFOther(1), ddsNetStatusNoOOF(2), ddsNetStatusOOF(3)  

ddsNetOOFCount 1.3.6.1.4.1.425.8.4.2.1.11
This count contains the number of consecutive seconds the unit has received the out of frame code.
OBJECT-TYPE    
  INTEGER  

ddsNetOOFThreshold 1.3.6.1.4.1.425.8.4.2.1.12
A period, measured in seconds, in which the Out Of Frame code is received or a frame sync loss occurred.
OBJECT-TYPE    
  INTEGER ddsNetOOFThresholdOther(1), ddsNetOOFThresholdNone(2), ddsNetOOFThreshold1(3), ddsNetOOFThreshold2(4), ddsNetOOFThreshold3(5), ddsNetOOFThreshold4(6), ddsNetOOFThreshold5(7), ddsNetOOFThreshold10(8), ddsNetOOFThreshold20(9), ddsNetOOFThreshold30(10)  

ddsNetOOFAlarm 1.3.6.1.4.1.425.8.4.2.1.13
This status indicates if the Out of Frame Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER ddsNetOOFSAlarmOther(1), ddsNetOOFSAlarmNone(2), ddsNetOOFSAlarmThresholdExceeded(3)  

ddsNetOOSStatus 1.3.6.1.4.1.425.8.4.2.1.14
Reports if Out of Service codes are received.
OBJECT-TYPE    
  INTEGER ddsNetStatusOOSOther(1), ddsNetStatusNoOOS(2), ddsNetStatusOOS(3)  

ddsNetOOSCount 1.3.6.1.4.1.425.8.4.2.1.15
This count contains the number of consecutive seconds the unit has received the out of service code.
OBJECT-TYPE    
  INTEGER  

ddsNetOOSThreshold 1.3.6.1.4.1.425.8.4.2.1.16
A period, measured in seconds, in which the Out Of Service code is received.
OBJECT-TYPE    
  INTEGER ddsNetOOSThresholdOther(1), ddsNetOOSThresholdNone(2), ddsNetOOSThreshold1(3), ddsNetOOSThreshold2(4), ddsNetOOSThreshold3(5), ddsNetOOSThreshold4(6), ddsNetOOSThreshold5(7), ddsNetOOSThreshold10(8), ddsNetOOSThreshold20(9), ddsNetOOSThreshold30(10)  

ddsNetOOSAlarm 1.3.6.1.4.1.425.8.4.2.1.17
This status indicates if the Out of Service Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER ddsNetOOSAlarmOther(1), ddsNetOOSAlarmNone(2), ddsNetOOSAlarmThresholdExceeded(3)  

ddsNetFDLStatus 1.3.6.1.4.1.425.8.4.2.1.18
Reports if Facility Data Link errors have occurred.
OBJECT-TYPE    
  INTEGER ddsNetStatusFDLOther(1), ddsNetStatusNoFDL(2), ddsNetStatusFDL(3)  

ddsNetFDLCount 1.3.6.1.4.1.425.8.4.2.1.19
This count contains the number of consecutive seconds in which FDL errors have occurred.
OBJECT-TYPE    
  INTEGER  

ddsNetFDLThreshold 1.3.6.1.4.1.425.8.4.2.1.20
A period, measured in seconds, in which FDL errors have occurred.
OBJECT-TYPE    
  INTEGER ddsNetFDLThresholdOther(1), ddsNetFDLThresholdNone(2), ddsNetFDLThreshold1(3), ddsNetFDLThreshold2(4), ddsNetFDLThreshold3(5), ddsNetFDLThreshold4(6), ddsNetFDLThreshold5(7), ddsNetFDLThreshold10(8), ddsNetFDLThreshold20(9), ddsNetFDLThreshold30(10)  

ddsNetFDLAlarm 1.3.6.1.4.1.425.8.4.2.1.21
This status indicates if the Facility Data Link threshold is exceeded.
OBJECT-TYPE    
  INTEGER ddsNetFDLAlarmOther(1), ddsNetFDLAlarmNone(2), ddsNetFDLAlarmThresholdExceeded(3)  

ddsNetAlarmResetTimer 1.3.6.1.4.1.425.8.4.2.1.22
Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.
OBJECT-TYPE    
  INTEGER  

ddsNetAlarmReset 1.3.6.1.4.1.425.8.4.2.1.23
This is used to clear the current alarm counts.
OBJECT-TYPE    
  INTEGER ddsNetAlarmResetOther(1), ddsNetAlarmResetClearAlarms(2)  

serialDte 1.3.6.1.4.1.425.8.5
OBJECT IDENTIFIER    

serialDteConfigTable 1.3.6.1.4.1.425.8.5.1
The Serial DTE Config Table.
OBJECT-TYPE    
  SEQUENCE OF  
    SerialDteConfigTableEntry

serialDteConfigTableEntry 1.3.6.1.4.1.425.8.5.1.1
An entry in the serial DTE Config Table.
OBJECT-TYPE    
  SerialDteConfigTableEntry  

serialDteConfigNearIndex 1.3.6.1.4.1.425.8.5.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

serialDteConfigFarIndex 1.3.6.1.4.1.425.8.5.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

serialDteConfigIndex 1.3.6.1.4.1.425.8.5.1.1.3
Index into the DteTable.
OBJECT-TYPE    
  INTEGER  

serialDteDescription 1.3.6.1.4.1.425.8.5.1.1.4
Contains a textual description of the port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

serialDteType 1.3.6.1.4.1.425.8.5.1.1.5
Selects the DTE port type if applicable.
OBJECT-TYPE    
  INTEGER serialDteTypeOther(1), serialDteTypeV35(2), serialDteTypeRS232(3), serialDteTypeEIA530(4)  

serialDteRate 1.3.6.1.4.1.425.8.5.1.1.6
Selects the DTE port bit.
OBJECT-TYPE    
  INTEGER serialDteRateOther(1), serialDteRate2400(2), serialDteRate4800(3), serialDteRate9600(4), serialDteRate19200(5), serialDteRate38400(6), serialDteRate52000(7), serialDteRate56000(8), serialDteRate57600(9), serialDteRate60000(10), serialDteRate64000(11), serialDteRate112000(12), serialDteRate128000(13), serialDteRate168000(14), serialDteRate192000(15), serialDteRate224000(16), serialDteRate256000(17), serialDteRate280000(18), serialDteRate320000(19), serialDteRate336000(20), serialDteRate384000(21), serialDteRate392000(22), serialDteRate448000(23), serialDteRate504000(24), serialDteRate512000(25), serialDteRate560000(26), serialDteRate576000(27), serialDteRate616000(28), serialDteRate640000(29), serialDteRate672000(30), serialDteRate704000(31), serialDteRate728000(32), serialDteRate768000(33), serialDteRate784000(34), serialDteRate832000(35), serialDteRate840000(36), serialDteRate896000(37), serialDteRate952000(38), serialDteRate960000(39), serialDteRate1008000(40), serialDteRate1024000(41), serialDteRate1064000(42), serialDteRate1088000(43), serialDteRate1120000(44), serialDteRate1152000(45), serialDteRate1176000(46), serialDteRate1216000(47), serialDteRate1232000(48), serialDteRate1280000(49), serialDteRate1288000(50), serialDteRate1344000(51), serialDteRate1400000(52), serialDteRate1408000(53), serialDteRate1456000(54), serialDteRate1472000(55), serialDteRate1512000(56), serialDteRate1536000(57), serialDteRate1568000(58), serialDteRate1600000(59), serialDteRate1624000(60), serialDteRate1664000(61), serialDteRate1680000(62), serialDteRate1728000(63), serialDteRate1736000(64), serialDteRate1792000(65), serialDteRate1856000(66), serialDteRate1920000(67), serialDteRate1984000(68), serialDteRate2048000(69), serialDteRate1200(70), serialDteRate14400(71), serialDteRate28800(72), serialDteRate48000(73), serialDteRate31200(74), serialDteRate115200(75)  

serialDteInvertData 1.3.6.1.4.1.425.8.5.1.1.7
Specifies whether transmit and receive are inverted at the port.
OBJECT-TYPE    
  INTEGER serialDteInvertDataOther(1), serialDteInvertDataDisabled(2), serialDteInvertDataEnabled(3)  

serialDteFormat 1.3.6.1.4.1.425.8.5.1.1.8
This variable describes the current operations format of the DTE interface. The values mean: serialDteFormatSync The DTE interface is currently set to operate in Syncronous clocking format serialDteFormatAsync The DTE interface is currently set to operate in the Asyncronous clocking format serialDteFormatNotAvail The DTE interface operating format is not available
OBJECT-TYPE    
  INTEGER serialDteFormatOther(1), serialDteFormatSync(2), serialDteFormatAsync(3), serialDteFormatNotAvail(4)  

serialDteParity 1.3.6.1.4.1.425.8.5.1.1.9
This variable describes the current parity selected for the DTE interface. This variable is only valid when the DTE Mode is set to ASYNC. The values mean: serialDteParityNone The DTE interface is currently set for no parity bit checking or generation serialDteParityOdd The DTE interface is currently set for odd parity serialDteParityEven The DTE interface is currently set for even parity serialDteParityMark The DTE interface is currently set for mark parity serialDteParitySpace The DTE interface is currently set for space parity serialDteParityNotAvail The parity setting on the DTE interface is not available.
OBJECT-TYPE    
  INTEGER serialDteParityOther(1), serialDteParityNone(2), serialDteParityOdd(3), serialDteParityEven(4), serialDteParityMark(5), serialDteParitySpace(6), serialDteParityNotAvail(7)  

serialDteStopBit 1.3.6.1.4.1.425.8.5.1.1.10
This variable describes the stop bit setting for the DTE interface. This variable is only valid when the DTE interface is set to ASYNC. The values mean: serialDteStopBit1 The DTE interface is configured to operate in the ASYNC mode with 1 stop bit serialDteStopBit2 The DTE interface is configured to operate in the ASYNC mode with 2 stop bits serialDteStopBitNotAvail The stop bit information is not available. The DTE interface is probably configured for synchronous operation.
OBJECT-TYPE    
  INTEGER serialDteStopBitOther(1), serialDteStopBit1(2), serialDteStopBit2(3), serialDteStopBitNotAvail(4)  

serialDteMode 1.3.6.1.4.1.425.8.5.1.1.11
This variable describes mode in which data is being sent from the DDS unit back towards the network.
OBJECT-TYPE    
  INTEGER serialDteModeOther(1), serialDteModeDDSI(2), serialDteModeDDSII(3), serialDteModeTxpINormal(4), serialDteModeTxpITDM(5), serialDteModeTxpIINormal(6), serialDteModeTxpIITDM(7)  

serialDteDSR 1.3.6.1.4.1.425.8.5.1.1.12
Selects DSR behavior.
OBJECT-TYPE    
  INTEGER serialDteDSROther(1), serialDteDSRTestOff(2), serialDteDSRForcedOn(3), serialDteDSRForcedOff(4), serialDteDSRInternal(5)  

serialDteDCD 1.3.6.1.4.1.425.8.5.1.1.13
Selects DCD behavior.
OBJECT-TYPE    
  INTEGER serialDteDCDOther(1), serialDteDCDIdleOff(2), serialDteDCDForcedOn(3), serialDteDCDForcedOff(4), serialDteDCDInternal(5), serialDteDCDFarRTS(6)  

serialDteRTS 1.3.6.1.4.1.425.8.5.1.1.14
Selects RTS behavior.
OBJECT-TYPE    
  INTEGER serialDteRTSOther(1), serialDteRTSNormal(2), serialDteRTSForcedOn(3), serialDteRTSExternal(4)  

serialDteRTSDelay 1.3.6.1.4.1.425.8.5.1.1.15
Selects RTS to CTS transition delay.
OBJECT-TYPE    
  INTEGER serialDteRTSDelayOther(1), serialDteRTSDelayNormal(2), serialDteRTSDelayLong(3)  

serialDteDTR 1.3.6.1.4.1.425.8.5.1.1.16
Reports if DTR from the DTE device is false.
OBJECT-TYPE    
  INTEGER serialDteDTROther(1), serialDteDTRFalse(2), serialDteDTRTrue(3)  

serialDteCTS 1.3.6.1.4.1.425.8.5.1.1.17
Specifies the control of the CTS signal at the port.
OBJECT-TYPE    
  INTEGER serialDteCTSOther(1), serialDteCTSForceTrue(2), serialDteCTSForceFalse(3), serialDteCTSInternal(4)  

serialDteV54 1.3.6.1.4.1.425.8.5.1.1.18
Specifies if the unit should respond to inband V.54 loop commands.
OBJECT-TYPE    
  INTEGER serialDteV54Other(1), serialDteV54Disable(2), serialDteV54Enable(3)  

serialDteLL 1.3.6.1.4.1.425.8.5.1.1.19
Specifies if the unit should respond to local loop activation by the local loopback signal (EIA530 or RS-232 pin 18).
OBJECT-TYPE    
  INTEGER serialDteLLOther(1), serialDteLLDisable(2), serialDteLLEnable(3)  

serialDteRL 1.3.6.1.4.1.425.8.5.1.1.20
Specifies if the unit should respond to remote loop activation by the remote loopback signal (EIA530 or RS-232 pin 21).
OBJECT-TYPE    
  INTEGER serialDteRLOther(1), serialDteRLDisable(2), serialDteRLEnable(3)  

serialDteStartChannel 1.3.6.1.4.1.425.8.5.1.1.21
Specifies the starting channel for the interface.
OBJECT-TYPE    
  INTEGER  

serialDteNumberOfChannels 1.3.6.1.4.1.425.8.5.1.1.22
Specifies the number of channels allocated to the interface.
OBJECT-TYPE    
  INTEGER  

serialDteTxClock 1.3.6.1.4.1.425.8.5.1.1.23
Specifies how the interface derives its transmit clock.
OBJECT-TYPE    
  INTEGER serialDteTxClockOther(1), serialDteTxClockInternal(2), serialDteTxClockExternal(3), serialDteTxClockOversample(4)  

serialDteBundle 1.3.6.1.4.1.425.8.5.1.1.24
Specifies the allocation pattern of channels assigned to the serial port.
OBJECT-TYPE    
  INTEGER other(1), contiguous(2), alternate(3)  

serialDteChannelRate 1.3.6.1.4.1.425.8.5.1.1.25
Specifies the rate of all channels assigned to the serial port.
OBJECT-TYPE    
  INTEGER other(1), nx56k(2), nx64k(3)  

serialDteInvertClock 1.3.6.1.4.1.425.8.5.1.1.26
Specifies if an inverted clock is used to send data from the serial port.
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

serialDteAlarmTable 1.3.6.1.4.1.425.8.5.2
The Serial DTE Alarm Table.
OBJECT-TYPE    
  SEQUENCE OF  
    SerialDteAlarmTableEntry

serialDteAlarmTableEntry 1.3.6.1.4.1.425.8.5.2.1
An entry in the serial DTE Alarm Table.
OBJECT-TYPE    
  SerialDteAlarmTableEntry  

serialDteAlarmNearIndex 1.3.6.1.4.1.425.8.5.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

serialDteAlarmFarIndex 1.3.6.1.4.1.425.8.5.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

serialDteAlarmIndex 1.3.6.1.4.1.425.8.5.2.1.3
Index into the serialDteAlarmTable.
OBJECT-TYPE    
  INTEGER  

serialDteDTRAlarmControl 1.3.6.1.4.1.425.8.5.2.1.4
Specifies if the unit should alarm on loss of DTR.
OBJECT-TYPE    
  INTEGER serialDteDTRAlarmOther(1), serialDteDTRAlarmDisable(2), serialDteDTRAlarmEnable(3)  

serialDteDTRAlarmStatus 1.3.6.1.4.1.425.8.5.2.1.5
This status indicates a DTR Loss alarm is active.
OBJECT-TYPE    
  INTEGER serialDteDTRAlarmOther(1), serialDteDTRAlarmNone(2), serialDteDTRAlarmActive(3)  

serialDteStatusSummary 1.3.6.1.4.1.425.8.5.2.1.6
This object provides a summary of the port status.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

serialDteAlarmSummary 1.3.6.1.4.1.425.8.5.2.1.7
This object provides a summary of the port alarms.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

serialDteASCStatus 1.3.6.1.4.1.425.8.5.2.1.8
Reports if an ASC condition exists on the interface.
OBJECT-TYPE    
  INTEGER serialDteStatusASCOther(1), serialDteStatusNoASC(2), serialDteStatusASC(3)  

serialDteASCCount 1.3.6.1.4.1.425.8.5.2.1.9
This count contains the number of ASC seconds received by the interface.
OBJECT-TYPE    
  INTEGER  

serialDteASCThreshold 1.3.6.1.4.1.425.8.5.2.1.10
The number of ASC seconds that must be received before an alarm is declared.
OBJECT-TYPE    
  INTEGER  

serialDteASCAlarm 1.3.6.1.4.1.425.8.5.2.1.11
This status indicates if the ASC Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER serialDteASCAlarmOther(1), serialDteASCAlarmNone(2), serialDteASCAlarmThresholdExceeded(3)  

serialDteFDLStatus 1.3.6.1.4.1.425.8.5.2.1.12
Reports if an FDL error condition exists on the interface.
OBJECT-TYPE    
  INTEGER serialDteStatusFDLOther(1), serialDteStatusNoFDL(2), serialDteStatusFDL(3)  

serialDteFDLCount 1.3.6.1.4.1.425.8.5.2.1.13
This count contains the number of FDL errored seconds received by the interface.
OBJECT-TYPE    
  INTEGER  

serialDteFDLThreshold 1.3.6.1.4.1.425.8.5.2.1.14
The number of FDL errored seconds that must be received before an alarm is declared.
OBJECT-TYPE    
  INTEGER  

serialDteFDLAlarm 1.3.6.1.4.1.425.8.5.2.1.15
This status indicates if the FDL Errored Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER serialDteFDLAlarmOther(1), serialDteFDLAlarmNone(2), serialDteFDLAlarmThresholdExceeded(3)  

serialDteLOSStatus 1.3.6.1.4.1.425.8.5.2.1.16
Reports if an LOS condition exists on the interface.
OBJECT-TYPE    
  INTEGER serialDteStatusLOSOther(1), serialDteStatusNoLOS(2), serialDteStatusLOS(3)  

serialDteLOSCount 1.3.6.1.4.1.425.8.5.2.1.17
This count contains the number of LOS seconds received by the interface.
OBJECT-TYPE    
  INTEGER  

serialDteLOSThreshold 1.3.6.1.4.1.425.8.5.2.1.18
The number of LOS seconds that must be received before an alarm is declared.
OBJECT-TYPE    
  INTEGER  

serialDteLOSAlarm 1.3.6.1.4.1.425.8.5.2.1.19
This status indicates if the LOS Seconds threshold is exceeded.
OBJECT-TYPE    
  INTEGER serialDteLOSAlarmOther(1), serialDteLOSAlarmNone(2), serialDteLOSAlarmThresholdExceeded(3)  

analogDte 1.3.6.1.4.1.425.8.6
OBJECT IDENTIFIER    

analogDteTable 1.3.6.1.4.1.425.8.6.1
The Analog DTE Table.
OBJECT-TYPE    
  SEQUENCE OF  
    AnalogDteTableEntry

analogDteTableEntry 1.3.6.1.4.1.425.8.6.1.1
An entry in the Analog DTE Table.
OBJECT-TYPE    
  AnalogDteTableEntry  

analogDteNearIndex 1.3.6.1.4.1.425.8.6.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

analogDteFarIndex 1.3.6.1.4.1.425.8.6.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

analogDteIndex 1.3.6.1.4.1.425.8.6.1.1.3
Index into the analogDteTable.
OBJECT-TYPE    
  INTEGER  

analogDteDescription 1.3.6.1.4.1.425.8.6.1.1.4
Contains a textual description of the port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

analogDteCardType 1.3.6.1.4.1.425.8.6.1.1.5
Identifies the analog DTE card type.
OBJECT-TYPE    
  INTEGER analogDteCardTypeOther(1), analogDteCardTypeFXS(2), analogDteCardTypeFXO(3), analogDteCardType4WEM(4)  

analogDteMode 1.3.6.1.4.1.425.8.6.1.1.6
Selects whether the port is actively assigned to a netowrk channel or not used.
OBJECT-TYPE    
  INTEGER analogDteModeOther(1), analogDteModeSpare(2), analogDteModeActive(3)  

analogDteState 1.3.6.1.4.1.425.8.6.1.1.7
Displays the port status as either in the Busy or Idle state.
OBJECT-TYPE    
  INTEGER analogDteStateOther(1), analogDteStateIdle(2), analogDteStateBusy(3)  

analogDteElementID 1.3.6.1.4.1.425.8.6.1.1.8
This object signifies the name of the device.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

analogDteSignalling 1.3.6.1.4.1.425.8.6.1.1.9
Selects the supervisory operation of the port.
OBJECT-TYPE    
  INTEGER analogDteSignallingOther(1), analogDteSignallingFXSLS(2), analogDteSignallingFXSGS(3), analogDteSignallingUVG(4), analogDteSignallingMEGLS(5), analogDteSignallingMEGGS(6), analogDteSignallingMEGRLS(7), analogDteSignallingMEGRGS(8), analogDteSignallingPLAR(9), analogDteSignallingSLC96(10), analogDteSignallingDIDDNIS(11), analogDteSignallingDNISWLS(12), analogDteSignallingDNISDLS(13), analogDteSignallingDNISWRLS(14), analogDteSignallingDNISDRLS(15), analogDteSignallingDNISWGS(16), analogDteSignallingDNISDGS(17), analogDteSignallingDNISWRGS(18), analogDteSignallingDNISDRGS(19), analogDteSignallingFXOLS(20), analogDteSignallingFXOGS(21), analogDteSignallingFXOUVG(22), analogDteSignallingFXOUVGR(23), analogDteSignalling4WEMTYPE1(24), analogDteSignalling4WEMTYPE2(25), analogDteSignalling4WEMTYPE3(26), analogDteSignalling4WEMTYPE4(27), analogDteSignalling4WEMTYPE5(28), analogDteSignalling4WEMTO(29)  

analogDteDNISDelay 1.3.6.1.4.1.425.8.6.1.1.10
If the signalling mode has a delay, it can be set from 1 to 5 seconds.
OBJECT-TYPE    
  INTEGER analogDteDNISDelayOther(1), analogDteDNISDelay1Second(2), analogDteDNISDelay2Seconds(3), analogDteDNISDelay3Seconds(4), analogDteDNISDelay4Seconds(5), analogDteDNISDelay5Seconds(6)  

analogDteTxGain 1.3.6.1.4.1.425.8.6.1.1.11
Selects the transmit gain. Values prefixed with m are negative.
OBJECT-TYPE    
  INTEGER analogDteTxGainOther(1), analogDteTxGain3DB(2), analogDteTxGain2DB(3), analogDteTxGain1DB(4), analogDteTxGain0DB(5), analogDteTxGainm1DB(6), analogDteTxGainm2DB(7), analogDteTxGainm3DB(8), analogDteTxGainm4DB(9), analogDteTxGainm5DB(10), analogDteTxGainm6DB(11), analogDteTxGainm7DB(12), analogDteTxGainm8DB(13), analogDteTxGainm9DB(14), analogDteTxGainm10DB(15)  

analogDteRxGain 1.3.6.1.4.1.425.8.6.1.1.12
Selects the receive gain. Values prefixed with m are negative.
OBJECT-TYPE    
  INTEGER analogDteRxGainOther(1), analogDteRxGain2DB(2), analogDteRxGain1DB(3), analogDteRxGain0DB(4), analogDteRxGainm1DB(5), analogDteRxGainm2DB(6), analogDteRxGainm3DB(7), analogDteRxGainm4DB(8), analogDteRxGainm5DB(9), analogDteRxGainm6DB(10), analogDteRxGainm7DB(11), analogDteRxGainm8DB(12), analogDteRxGainm9DB(13), analogDteRxGainm10DB(14), analogDteRxGainm11DB(15), analogDteRxGainm12DB(16), analogDteRxGainm13DB(17), analogDteRxGainm14DB(18), analogDteRxGainm15DB(19), analogDteRxGainm16DB(20)  

connection 1.3.6.1.4.1.425.8.7
OBJECT IDENTIFIER    

connectionTable 1.3.6.1.4.1.425.8.7.1
The connection table.
OBJECT-TYPE    
  SEQUENCE OF  
    ConnectionTableEntry

connectionTableEntry 1.3.6.1.4.1.425.8.7.1.1
An entry in the connection table.
OBJECT-TYPE    
  ConnectionTableEntry  

connectionNearIndex 1.3.6.1.4.1.425.8.7.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

connectionFarIndex 1.3.6.1.4.1.425.8.7.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

connectionTableIndex 1.3.6.1.4.1.425.8.7.1.1.3
The index into the connection table.
OBJECT-TYPE    
  INTEGER  

connectionTableDescription 1.3.6.1.4.1.425.8.7.1.1.4
A description of the connection.
OBJECT-TYPE    
  DisplayString SIZE(0..60)  

connectionChannelTable 1.3.6.1.4.1.425.8.7.2
The channel-level connection table.
OBJECT-TYPE    
  SEQUENCE OF  
    ConnectionChannelEntry

connectionChannelEntry 1.3.6.1.4.1.425.8.7.2.1
An entry in the connectionChannelTable.
OBJECT-TYPE    
  ConnectionChannelEntry  

connectionChannelNearIndex 1.3.6.1.4.1.425.8.7.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

connectionChannelFarIndex 1.3.6.1.4.1.425.8.7.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

connectionChannelLineIndex 1.3.6.1.4.1.425.8.7.2.1.3
Selects instance of line.
OBJECT-TYPE    
  INTEGER  

connectionChannelIndex 1.3.6.1.4.1.425.8.7.2.1.4
The index into the connection table.
OBJECT-TYPE    
  INTEGER  

channelInterfaceAssignment 1.3.6.1.4.1.425.8.7.2.1.5
The channel assignment.
OBJECT-TYPE    
  INTEGER other(1), unassigned(2), dTE(3), remComm(4), port1(5), port2(6), port3(7), port4(8), port5(9), port6(10), port7(11), port8(12), port9(13), port10(14), port11(15), port12(16), port13(17), port14(18), port15(19), port16(20), port17(21), port18(22), port19(23), port20(24), port21(25), port22(26), port23(27), port24(28), port25(29), port26(30), port27(31), port28(32), port29(33), port30(34), port31(35), port32(36), slot2PortA(37), slot2PortB(38), slot3PortA(39), slot3PortB(40), slot4PortA(41), slot4PortB(42), slot5PortA(43), slot5PortB(44), slot6PortA(45), slot6PortB(46), slot2Dsu1PortA(47), slot2Dsu1PortB(48), slot2Dsu2PortA(49), slot2Dsu2PortB(50), slot2Dsu3PortA(51), slot2Dsu3PortB(52), slot2Dsu4PortA(53), slot2Dsu4PortB(54), slot2Dsu5PortA(55), slot2Dsu5PortB(56), slot2Dsu6PortA(57), slot2Dsu6PortB(58), slot3Dsu1PortA(59), slot3Dsu1PortB(60), slot3Dsu2PortA(61), slot3Dsu2PortB(62), slot3Dsu3PortA(63), slot3Dsu3PortB(64), slot3Dsu4PortA(65), slot3Dsu4PortB(66), slot3Dsu5PortA(67), slot3Dsu5PortB(68), slot3Dsu6PortA(69), slot3Dsu6PortB(70), slot4Dsu1PortA(71), slot4Dsu1PortB(72), slot4Dsu2PortA(73), slot4Dsu2PortB(74), slot4Dsu3PortA(75), slot4Dsu3PortB(76), slot4Dsu4PortA(77), slot4Dsu4PortB(78), slot4Dsu5PortA(79), slot4Dsu5PortB(80), slot4Dsu6PortA(81), slot4Dsu6PortB(82), slot5Dsu1PortA(83), slot5Dsu1PortB(84), slot5Dsu2PortA(85), slot5Dsu2PortB(86), slot5Dsu3PortA(87), slot5Dsu3PortB(88), slot5Dsu4PortA(89), slot5Dsu4PortB(90), slot5Dsu5PortA(91), slot5Dsu5PortB(92), slot5Dsu6PortA(93), slot5Dsu6PortB(94), slot6Dsu1PortA(95), slot6Dsu1PortB(96), slot6Dsu2PortA(97), slot6Dsu2PortB(98), slot6Dsu3PortA(99), slot6Dsu3PortB(100), slot6Dsu4PortA(101), slot6Dsu4PortB(102), slot6Dsu5PortA(103), slot6Dsu5PortB(104), slot6Dsu6PortA(105), slot6Dsu6PortB(106)  

channelInterfaceDescription 1.3.6.1.4.1.425.8.7.2.1.6
Contains a description of the interface channel connection.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

channelInterfaceChannel 1.3.6.1.4.1.425.8.7.2.1.7
Displays the corresponding channel of the interface channel connection.
OBJECT-TYPE    
  INTEGER  

channelSignalling 1.3.6.1.4.1.425.8.7.2.1.8
Allows a selection of Clear Channel or Robbed Bit signalling for each DS0.
OBJECT-TYPE    
  INTEGER other(1), clearChannel(2), robbedBit(3)  

maintenance 1.3.6.1.4.1.425.8.8
OBJECT IDENTIFIER    

bertTable 1.3.6.1.4.1.425.8.8.1
BERT control table.
OBJECT-TYPE    
  SEQUENCE OF  
    BertTableEntry

bertTableEntry 1.3.6.1.4.1.425.8.8.1.1
An entry in the BERT control table.
OBJECT-TYPE    
  BertTableEntry  

bertNearIndex 1.3.6.1.4.1.425.8.8.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

bertFarIndex 1.3.6.1.4.1.425.8.8.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

bertIndex 1.3.6.1.4.1.425.8.8.1.1.3
The index into the BERT control table. Selects which BERT chip to use.
OBJECT-TYPE    
  INTEGER  

bertPattern 1.3.6.1.4.1.425.8.8.1.1.4
Selects the test pattern to be used.
OBJECT-TYPE    
  INTEGER bertPatternOther(1), bertPatternQRSS(2), bertPattern63(3), bertPattern511(4), bertPattern2047(5), bertPattern215(6), bertPattern220(7), bertPattern223(8), bertPattern1in8(9), bertPattern3in24(10), bertPatternALT(11), bertPatternCLEAR(12)  

bertLength 1.3.6.1.4.1.425.8.8.1.1.5
Specifies how long the test should run.
OBJECT-TYPE    
  INTEGER bertLengthOther(1), bertLength15minutes(2), bertLength30minutes(3), bertLength60minutes(4), bertLength24hours(5), bertLengthContinuous(6)  

bertPatternSync 1.3.6.1.4.1.425.8.8.1.1.6
Displays the current state of pattern sync during a test.
OBJECT-TYPE    
  INTEGER bertPatternSyncOther(1), bertPatternSyncNoTest(2), bertPatternSyncNoSync(3), bertPatternSyncInsync(4)  

bertElapsedTime 1.3.6.1.4.1.425.8.8.1.1.7
Displays the amount of time elapsed since a timed test began in seconds.
OBJECT-TYPE    
  INTEGER  

bertBitErrors 1.3.6.1.4.1.425.8.8.1.1.8
Displays the total number of bit errors detected since the test began.
OBJECT-TYPE    
  INTEGER  

bertErroredSeconds 1.3.6.1.4.1.425.8.8.1.1.9
Displays the number of asynchronous errored seconds that have been detected since the test began.
OBJECT-TYPE    
  INTEGER  

bertPercentEFS 1.3.6.1.4.1.425.8.8.1.1.10
Displays a ratio derived from the number of error free seconds divided by the number of seconds accumulated in elapsed time.
OBJECT-TYPE    
  INTEGER  

bertCommand 1.3.6.1.4.1.425.8.8.1.1.11
Issues a test command for the interface.
OBJECT-TYPE    
  INTEGER bertCommandOther(1), bertCommandStart(2), bertCommandStop(3), bertCommandResetErrors(4), bertCommandInjectError(5)  

bertInterfaceTable 1.3.6.1.4.1.425.8.8.2
BERT control interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    BertInterfaceTableEntry

bertInterfaceTableEntry 1.3.6.1.4.1.425.8.8.2.1
An entry in the BERT control interface table.
OBJECT-TYPE    
  BertInterfaceTableEntry  

bertInterfaceNearIndex 1.3.6.1.4.1.425.8.8.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

bertInterfaceFarIndex 1.3.6.1.4.1.425.8.8.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

bertChipIndex 1.3.6.1.4.1.425.8.8.2.1.3
Selects which BERT chip to use.
OBJECT-TYPE    
  INTEGER  

bertInterfaceIndex 1.3.6.1.4.1.425.8.8.2.1.4
An index into the MIB-II interfaces table; the interface for the BERT settings.
OBJECT-TYPE    
  INTEGER  

bertInterfaceSetting 1.3.6.1.4.1.425.8.8.2.1.5
Specifies the interface for the BERT chip.
OBJECT-TYPE    
  INTEGER bertInterfaceSettingOther(1), bertInterfaceSettingIdle(2), bertInterfaceSettingChannel1(3), bertInterfaceSettingChannel2(4), bertInterfaceSettingChannel3(5), bertInterfaceSettingChannel4(6), bertInterfaceSettingChannel5(7), bertInterfaceSettingChannel6(8), bertInterfaceSettingChannel7(9), bertInterfaceSettingChannel8(10), bertInterfaceSettingChannel9(11), bertInterfaceSettingChannel10(12), bertInterfaceSettingChannel11(13), bertInterfaceSettingChannel12(14), bertInterfaceSettingChannel13(15), bertInterfaceSettingChannel14(16), bertInterfaceSettingChannel15(17), bertInterfaceSettingChannel16(18), bertInterfaceSettingChannel17(19), bertInterfaceSettingChannel18(20), bertInterfaceSettingChannel19(21), bertInterfaceSettingChannel20(22), bertInterfaceSettingChannel21(23), bertInterfaceSettingChannel22(24), bertInterfaceSettingChannel23(25), bertInterfaceSettingChannel24(26), bertInterfaceSettingChannel25(27), bertInterfaceSettingChannel26(28), bertInterfaceSettingChannel27(29), bertInterfaceSettingChannel28(30), bertInterfaceSettingChannel29(31), bertInterfaceSettingChannel30(32), bertInterfaceSettingChannel31(33), bertInterfaceSettingChannel32(34), bertInterfaceSettingNet(35), bertInterfaceSettingDTE(36), bertInterfaceSettingNotEnabled(37)  

testTable 1.3.6.1.4.1.425.8.8.3
Test control table.
OBJECT-TYPE    
  SEQUENCE OF  
    TestTableEntry

testTableEntry 1.3.6.1.4.1.425.8.8.3.1
An entry in the testTable.
OBJECT-TYPE    
  TestTableEntry  

testNearIndex 1.3.6.1.4.1.425.8.8.3.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

testFarIndex 1.3.6.1.4.1.425.8.8.3.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

testTableIndex 1.3.6.1.4.1.425.8.8.3.1.3
The index into the testTable, one entry for each interface.
OBJECT-TYPE    
  INTEGER  

testType 1.3.6.1.4.1.425.8.8.3.1.4
Identifies the test type for the interface.
OBJECT-TYPE    
  INTEGER testTypeOther(1), testTypeNoTest(2), testTypePLB(3), testTypeLLB(4), testtypeMLB(5), testTypeFarPLB(6), testTypeFarLLB(7), testTypeFarMLB(8), testTypePortLoop(9), testTypeV54Loop(10), testTypeFarV54Loop(11)  

testLoopDirection 1.3.6.1.4.1.425.8.8.3.1.5
This object is the identifier of the current unit loop mode. The values mean: testLoopUnidirectional Line, Data, and V54 loops will be unidirectional Local loop will be bidirectional testLoopBidirectional All loops will be bidirectional
OBJECT-TYPE    
  INTEGER testLoopOther(1), testLoopUnidirectional(2), testLoopBidirectional(3)  

testFarLLBFraming 1.3.6.1.4.1.425.8.8.3.1.6
This setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing.
OBJECT-TYPE    
  INTEGER testFarLLBFramingOther(1), testFarLLBFramingUnframed(2), testFarLLBFramingFramed(3)  

performance 1.3.6.1.4.1.425.8.9
OBJECT IDENTIFIER    

performance24Table 1.3.6.1.4.1.425.8.9.1
Performance table, contains TR54016 standard and enhanced data.
OBJECT-TYPE    
  SEQUENCE OF  
    Performance24TableEntry

performance24TableEntry 1.3.6.1.4.1.425.8.9.1.1
An entry in the performance24Table.
OBJECT-TYPE    
  Performance24TableEntry  

performance24NearIndex 1.3.6.1.4.1.425.8.9.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

performance24FarIndex 1.3.6.1.4.1.425.8.9.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

performance24InterfaceIndex 1.3.6.1.4.1.425.8.9.1.1.3
Selects the interface.
OBJECT-TYPE    
  INTEGER  

performance24Index 1.3.6.1.4.1.425.8.9.1.1.4
The index into the 24-hour performance table.
OBJECT-TYPE    
  INTEGER performance24Summary(1), performance24Current(2), performance24period1(3), performance24period2(4), performance24period3(5), performance24period4(6), performance24period5(7), performance24period6(8), performance24period7(9), performance24period8(10), performance24period9(11), performance24period10(12), performance24period11(13), performance24period12(14), performance24period13(15), performance24period14(16), performance24period15(17), performance24period16(18), performance24period17(19), performance24period18(20), performance24period19(21), performance24period20(22), performance24period21(23), performance24period22(24), performance24period23(25), performance24period24(26), performance24period25(27), performance24period26(28), performance24period27(29), performance24period28(30), performance24period29(31), performance24period30(32), performance24period31(33), performance24period32(34), performance24period33(35), performance24period34(36), performance24period35(37), performance24period36(38), performance24period37(39), performance24period38(40), performance24period39(41), performance24period40(42), performance24period41(43), performance24period42(44), performance24period43(45), performance24period44(46), performance24period45(47), performance24period46(48), performance24period47(49), performance24period48(50), performance24period49(51), performance24period50(52), performance24period51(53), performance24period52(54), performance24period53(55), performance24period54(56), performance24period55(57), performance24period56(58), performance24period57(59), performance24period58(60), performance24period59(61), performance24period60(62), performance24period61(63), performance24period62(64), performance24period63(65), performance24period64(66), performance24period65(67), performance24period66(68), performance24period67(69), performance24period68(70), performance24period69(71), performance24period70(72), performance24period71(73), performance24period72(74), performance24period73(75), performance24period74(76), performance24period75(77), performance24period76(78), performance24period77(79), performance24period78(80), performance24period79(81), performance24period80(82), performance24period81(83), performance24period82(84), performance24period83(85), performance24period84(86), performance24period85(87), performance24period86(88), performance24period87(89), performance24period88(90), performance24period89(91), performance24period90(92), performance24period91(93), performance24period92(94), performance24period93(95), performance24period94(96), performance24period95(97), performance24period96(98)  

performance24ES 1.3.6.1.4.1.425.8.9.1.1.5
The number of Errored Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24BES 1.3.6.1.4.1.425.8.9.1.1.6
The number of Bursty Errored Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24SES 1.3.6.1.4.1.425.8.9.1.1.7
The number of Severely Errored Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24UAS 1.3.6.1.4.1.425.8.9.1.1.8
The number of Unavailable Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24LOFC 1.3.6.1.4.1.425.8.9.1.1.9
The number of Loss of Frame Counts for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24CSS 1.3.6.1.4.1.425.8.9.1.1.10
The number of Controlled Slip Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24CRCES 1.3.6.1.4.1.425.8.9.1.1.11
The number of CRC Errored Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24OOFS 1.3.6.1.4.1.425.8.9.1.1.12
The number of Out of Frame Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24LOSS 1.3.6.1.4.1.425.8.9.1.1.13
The number of Loss of Signal Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24AISS 1.3.6.1.4.1.425.8.9.1.1.14
The number of Alarm Indication Signal Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24RAS 1.3.6.1.4.1.425.8.9.1.1.15
The number of Remote Alarm (Yellow) Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance24BPVS 1.3.6.1.4.1.425.8.9.1.1.16
The number of Bipolar Violation Seconds for the 15-minute period.
OBJECT-TYPE    
  INTEGER  

performance30Table 1.3.6.1.4.1.425.8.9.2
Performance table, contains TR54016 standard and enhanced 30-day data.
OBJECT-TYPE    
  SEQUENCE OF  
    Performance30TableEntry

performance30TableEntry 1.3.6.1.4.1.425.8.9.2.1
An entry in the performance30Table.
OBJECT-TYPE    
  Performance30TableEntry  

performance30NearIndex 1.3.6.1.4.1.425.8.9.2.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

performance30FarIndex 1.3.6.1.4.1.425.8.9.2.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

performance30InterfaceIndex 1.3.6.1.4.1.425.8.9.2.1.3
Selects the interface.
OBJECT-TYPE    
  INTEGER  

performance30Index 1.3.6.1.4.1.425.8.9.2.1.4
The index into the 30-day performance table.
OBJECT-TYPE    
  INTEGER performance30Summary(1), performance30day1(2), performance30day2(3), performance30day3(4), performance30day4(5), performance30day5(6), performance30day6(7), performance30day7(8), performance30day8(9), performance30day9(10), performance30day10(11), performance30day11(12), performance30day12(13), performance30day13(14), performance30day14(15), performance30day15(16), performance30day16(17), performance30day17(18), performance30day18(19), performance30day19(20), performance30day20(21), performance30day21(22), performance30day22(23), performance30day23(24), performance30day24(25), performance30day25(26), performance30day26(27), performance30day27(28), performance30day28(29), performance30day29(30), performance30day30(31)  

performance30ES 1.3.6.1.4.1.425.8.9.2.1.5
The number of Errored Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30BES 1.3.6.1.4.1.425.8.9.2.1.6
The number of Bursty Errored Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30SES 1.3.6.1.4.1.425.8.9.2.1.7
The number of Severely Errored Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30UAS 1.3.6.1.4.1.425.8.9.2.1.8
The number of Unavailable Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30LOFC 1.3.6.1.4.1.425.8.9.2.1.9
The number of Loss of Frame Counts for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30CSS 1.3.6.1.4.1.425.8.9.2.1.10
The number of Controlled Slip Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30CRCES 1.3.6.1.4.1.425.8.9.2.1.11
The number of CRC Errored Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30OOFS 1.3.6.1.4.1.425.8.9.2.1.12
The number of Out of Frame Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30LOSS 1.3.6.1.4.1.425.8.9.2.1.13
The number of Loss of Signal Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30AISS 1.3.6.1.4.1.425.8.9.2.1.14
The number of Alarm Indication Signal Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30RAS 1.3.6.1.4.1.425.8.9.2.1.15
The number of Remote Alarm (Yellow) Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

performance30BPVS 1.3.6.1.4.1.425.8.9.2.1.16
The number of Bipolar Violation Seconds for the 1-day period.
OBJECT-TYPE    
  INTEGER  

itable 1.3.6.1.4.1.425.8.10
OBJECT IDENTIFIER    

iTable 1.3.6.1.4.1.425.8.10.1
The interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    ITableEntry

iTableEntry 1.3.6.1.4.1.425.8.10.1.1
An entry in the interface table.
OBJECT-TYPE    
  ITableEntry  

iTableNearIndex 1.3.6.1.4.1.425.8.10.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

iTableFarIndex 1.3.6.1.4.1.425.8.10.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

iTableIndex 1.3.6.1.4.1.425.8.10.1.1.3
The index into the interface table, used for addressing in above tables.
OBJECT-TYPE    
  INTEGER  

iDescription 1.3.6.1.4.1.425.8.10.1.1.4
Description of the interface.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

iType 1.3.6.1.4.1.425.8.10.1.1.5
Enumerated interface type.
OBJECT-TYPE    
  INTEGER disabled(0), v35(1), eia530(2), rs232(3), voice(4), hsdata(5), dualt1dte(6), dualddsv1(7), hexdds(8), ocudp(9), x21(10), dualddsv2(11), rfdl(128), alt(129), t1dte(130), didte(131), t1ntw(132), e1ntw(133), ddsntw(134), ddsdte(135), ddsdbu(136), fxs(137), fxo(138), eandm(139), e1sig(192)  

iSlot 1.3.6.1.4.1.425.8.10.1.1.6
Device-dependent slot in which the interface resides.
OBJECT-TYPE    
  INTEGER  

iPort 1.3.6.1.4.1.425.8.10.1.1.7
Device-dependent port in which the interface resides.
OBJECT-TYPE    
  INTEGER  

iStatus 1.3.6.1.4.1.425.8.10.1.1.8
Status of the interface.
OBJECT-TYPE    
  INTEGER iStatusOther(1), iStatusOK(2), iStatusErrored(3), iStatusAlarmed(4), iStatusTesting(5)  

traplog 1.3.6.1.4.1.425.8.11
OBJECT IDENTIFIER    

traplogTable 1.3.6.1.4.1.425.8.11.1
The traplog table.
OBJECT-TYPE    
  SEQUENCE OF  
    TraplogEntry

traplogEntry 1.3.6.1.4.1.425.8.11.1.1
An entry in the traplog table.
OBJECT-TYPE    
  TraplogEntry  

traplogIndex 1.3.6.1.4.1.425.8.11.1.1.1
The index into the traplog table.
OBJECT-TYPE    
  INTEGER  

traplogNearIndex 1.3.6.1.4.1.425.8.11.1.1.2
Specifies the near device.
OBJECT-TYPE    
  INTEGER  

traplogFarIndex 1.3.6.1.4.1.425.8.11.1.1.3
Specifies the far device.
OBJECT-TYPE    
  INTEGER  

traplogInterfaceIndex 1.3.6.1.4.1.425.8.11.1.1.4
Specifies the interface.
OBJECT-TYPE    
  INTEGER  

traplogTrapNum 1.3.6.1.4.1.425.8.11.1.1.5
The SNMP trap id.
OBJECT-TYPE    
  INTEGER  

traplogTimeStamp 1.3.6.1.4.1.425.8.11.1.1.6
Time the SNMP was generated.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

traplogDeviceType 1.3.6.1.4.1.425.8.11.1.1.7
Specifies the device type for the trap.
OBJECT-TYPE    
  INTEGER other(1), none(2), t12000(3), e12048(4), e13021(5), t13000(6), t13001(7), t13002(8), t13030(9), t13060(10), t13101(11), t13102(12), t13111(13), t13112(14), dds4001(15), dds4101(16), dds4051(17), dds4151(18), dds41TDM(19), generic54016(20)  

traplogDeleteEntry 1.3.6.1.4.1.425.8.11.2
Writing the index of a trap to this object will delete the trap entry. Writing an index value of 0 will delete all entries.
OBJECT-TYPE    
  INTEGER  

traplogSortOption 1.3.6.1.4.1.425.8.11.3
Determines the order in which traps are presented.
OBJECT-TYPE    
  INTEGER other(1), ascendingtimestamp(2), ascendingunit(3)  

traplogLastTimeStamp 1.3.6.1.4.1.425.8.11.4
The timestamp of the newest trap in the trap log.
OBJECT-TYPE    
  TimeTicks  

unitUtilities 1.3.6.1.4.1.425.8.12
OBJECT IDENTIFIER    

unitUtilitiesTable 1.3.6.1.4.1.425.8.12.1
The unit utilities table.
OBJECT-TYPE    
  SEQUENCE OF  
    UnitUtilitiesTableEntry

unitUtilitiesTableEntry 1.3.6.1.4.1.425.8.12.1.1
An entry in the unit utilities table.
OBJECT-TYPE    
  UnitUtilitiesTableEntry  

unitUtilitiesNearIndex 1.3.6.1.4.1.425.8.12.1.1.1
Selects the near device.
OBJECT-TYPE    
  INTEGER  

unitUtilitiesFarIndex 1.3.6.1.4.1.425.8.12.1.1.2
Selects the far device.
OBJECT-TYPE    
  INTEGER  

unitUtilitiesLocalPassword 1.3.6.1.4.1.425.8.12.1.1.3
The password for local access to a device (VT100, front panel).
OBJECT-TYPE    
  DisplayString  

unitUtilitiesTime 1.3.6.1.4.1.425.8.12.1.1.4
This string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered as 034500 and 3:45PM is entered as 154500.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

unitUtilitiesDate 1.3.6.1.4.1.425.8.12.1.1.5
This string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is entered as 070497.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

unitUtilitiesMaintenanceReset 1.3.6.1.4.1.425.8.12.1.1.6
This field allows resetting the device to default values by reloading the start-up default configuration parameters.
OBJECT-TYPE    
  INTEGER other(1), reset(2), restart(3)  

unitUtilitiesAlarmResetTimer 1.3.6.1.4.1.425.8.12.1.1.7
This field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds.
OBJECT-TYPE    
  INTEGER  

unitUtilitiesAlarmClear 1.3.6.1.4.1.425.8.12.1.1.8
Writing a 2 to this field causes all existing alarms to be cleared immediatedly.
OBJECT-TYPE    
  INTEGER utilitiesAlarmClearOther(1), utilitiesAlarmClearNow(2)  

Defined Objects

MgmtPortsTableEntry  
SEQUENCE    
  INTEGER as mgmtPortsTableIndex  
  DisplayString as mgmtPortsDescription  
  DisplayString as mgmtPortsElementID  
  INTEGER as mgmtPortsMode  
  DisplayString as mgmtPortsDialPrefix  
  DisplayString as mgmtPortsPrimaryDialString  
  DisplayString as mgmtPortsSecondaryDialString  
  DisplayString as mgmtPortsExtInitString  
  INTEGER as mgmtPortsCompressedSlip  
  INTEGER as mgmtPortsInternalModem  

DbuConfigTableEntry  
SEQUENCE    
  INTEGER as dbuNearIndex  
  INTEGER as dbuFarIndex  
  INTEGER as dbuConfigTableIndex  
  DisplayString as dbuDescription  
  INTEGER as dbuRate  
  INTEGER as dbuMode  
  INTEGER as dbuFormat  
  DisplayString as dbuNumber  
  INTEGER as dbuStatus  
  INTEGER as dbuCommand  
  INTEGER as dbuActivator1  
  INTEGER as dbuActivator2  
  DisplayString as dbuDialStr  
  DisplayString as dbuInitStr  
  DisplayString as dbuHangupStr  
  DisplayString as dbuPasswordStr  
  INTEGER as dbuSecurity  
  INTEGER as dbuDtrDial  
  INTEGER as dbuISDNSwitchType  
  INTEGER as dbuISDNSwitchVersion  
  INTEGER as dbuISDNTEI  
  DisplayString as dbuISDNSPID  
  DisplayString as dbuISDNDDNUM  

DbuResetStringsEntry  
SEQUENCE    
  INTEGER as dbuResetNearIndex  
  INTEGER as dbuResetFarIndex  
  INTEGER as dbuResetConfigEntryIndex  
  INTEGER as dbuResetStringsIndex  
  DisplayString as dbuResetString  

DbuStartStopTableEntry  
SEQUENCE    
  INTEGER as dbuStartStopNearIndex  
  INTEGER as dbuStartStopFarIndex  
  INTEGER as dbuStartStopConfigEntryIndex  
  INTEGER as dbuStartStopDayOfWeek  
  INTEGER as dbuStart  
  INTEGER as dbuStop  

T1e1ConfigTableEntry  
SEQUENCE    
  INTEGER as t1e1ConfigNearIndex  
  INTEGER as t1e1ConfigFarIndex  
  INTEGER as t1e1ConfigIndex  
  DisplayString as t1e1Description  
  INTEGER as t1e1Mode  
  INTEGER as t1e1FrameType  
  INTEGER as t1e1LineCode  
  INTEGER as t1e1LineBuildOut  
  INTEGER as t1e1Timing  
  INTEGER as t1e1StationInTiming  
  INTEGER as t1e1StationTiming  
  INTEGER as t1e1PRM  
  INTEGER as t1e1ZeroSuppress  
  INTEGER as t1e1NationalBit  
  INTEGER as t1e1KeepAlive  
  INTEGER as t1e1CRC4Mode  
  INTEGER as t1e1DSXLevel  
  INTEGER as t1e1CRC  
  INTEGER as t1e1FDLPassThrough  
  INTEGER as t1e1AudibleAlarm  

T1e1AlarmTableEntry  
SEQUENCE    
  INTEGER as t1e1AlarmNearIndex  
  INTEGER as t1e1AlarmFarIndex  
  INTEGER as t1e1AlarmIndex  
  DisplayString as t1e1StatusSummary  
  DisplayString as t1e1AlarmSummary  
  INTEGER as t1e1ESStatus  
  INTEGER as t1e1ESCount  
  INTEGER as t1e1ESThreshold  
  INTEGER as t1e1ESAlarm  
  INTEGER as t1e1SESStatus  
  INTEGER as t1e1SESCount  
  INTEGER as t1e1SESThreshold  
  INTEGER as t1e1SESAlarm  
  INTEGER as t1e1LOSSStatus  
  INTEGER as t1e1LOSSCount  
  INTEGER as t1e1LOSSThreshold  
  INTEGER as t1e1LOSSAlarm  
  INTEGER as t1e1UASStatus  
  INTEGER as t1e1UASCount  
  INTEGER as t1e1UASThreshold  
  INTEGER as t1e1UASAlarm  
  INTEGER as t1e1CSSStatus  
  INTEGER as t1e1CSSCount  
  INTEGER as t1e1CSSThreshold  
  INTEGER as t1e1CSSAlarm  
  INTEGER as t1e1BPVSStatus  
  INTEGER as t1e1BPVSCount  
  INTEGER as t1e1BPVSThreshold  
  INTEGER as t1e1BPVSAlarm  
  INTEGER as t1e1OOFSStatus  
  INTEGER as t1e1OOFSCount  
  INTEGER as t1e1OOFSThreshold  
  INTEGER as t1e1OOFSAlarm  
  INTEGER as t1e1AISStatus  
  INTEGER as t1e1AISCount  
  INTEGER as t1e1AISThreshold  
  INTEGER as t1e1AISAlarm  
  INTEGER as t1e1RASStatus  
  INTEGER as t1e1RASCount  
  INTEGER as t1e1RASThreshold  
  INTEGER as t1e1RASAlarm  
  INTEGER as t1e1AlarmResetTimer  
  INTEGER as t1e1AlarmReset  

DdsNetConfigTableEntry  
SEQUENCE    
  INTEGER as ddsNetConfigNearIndex  
  INTEGER as ddsNetConfigFarIndex  
  INTEGER as ddsNetConfigIndex  
  DisplayString as ddsNetDescription  
  INTEGER as ddsNetRate  
  INTEGER as ddsNetMode  
  INTEGER as ddsNetTimingSource  
  INTEGER as ddsNetRemComm  
  INTEGER as ddsNetCircuitAssur  
  INTEGER as ddsNetAntiStrTimer  

DdsNetAlarmTableEntry  
SEQUENCE    
  INTEGER as ddsNetAlarmNearIndex  
  INTEGER as ddsNetAlarmFarIndex  
  INTEGER as ddsNetAlarmIndex  
  DisplayString as ddsNetStatusSummary  
  DisplayString as ddsNetAlarmSummary  
  INTEGER as ddsNetLOSStatus  
  INTEGER as ddsNetLOSCount  
  INTEGER as ddsNetLOSThreshold  
  INTEGER as ddsNetLOSAlarm  
  INTEGER as ddsNetOOFStatus  
  INTEGER as ddsNetOOFCount  
  INTEGER as ddsNetOOFThreshold  
  INTEGER as ddsNetOOFAlarm  
  INTEGER as ddsNetOOSStatus  
  INTEGER as ddsNetOOSCount  
  INTEGER as ddsNetOOSThreshold  
  INTEGER as ddsNetOOSAlarm  
  INTEGER as ddsNetFDLStatus  
  INTEGER as ddsNetFDLCount  
  INTEGER as ddsNetFDLThreshold  
  INTEGER as ddsNetFDLAlarm  
  INTEGER as ddsNetAlarmResetTimer  
  INTEGER as ddsNetAlarmReset  

SerialDteConfigTableEntry  
SEQUENCE    
  INTEGER as serialDteConfigNearIndex  
  INTEGER as serialDteConfigFarIndex  
  INTEGER as serialDteConfigIndex  
  DisplayString as serialDteDescription  
  INTEGER as serialDteType  
  INTEGER as serialDteRate  
  INTEGER as serialDteInvertData  
  INTEGER as serialDteFormat  
  INTEGER as serialDteParity  
  INTEGER as serialDteStopBit  
  INTEGER as serialDteMode  
  INTEGER as serialDteDSR  
  INTEGER as serialDteDCD  
  INTEGER as serialDteRTS  
  INTEGER as serialDteRTSDelay  
  INTEGER as serialDteDTR  
  INTEGER as serialDteCTS  
  INTEGER as serialDteV54  
  INTEGER as serialDteLL  
  INTEGER as serialDteRL  
  INTEGER as serialDteStartChannel  
  INTEGER as serialDteNumberOfChannels  
  INTEGER as serialDteTxClock  
  INTEGER as serialDteBundle  
  INTEGER as serialDteChannelRate  
  INTEGER as serialDteInvertClock  

SerialDteAlarmTableEntry  
SEQUENCE    
  INTEGER as serialDteAlarmNearIndex  
  INTEGER as serialDteAlarmFarIndex  
  INTEGER as serialDteAlarmIndex  
  INTEGER as serialDteDTRAlarmControl  
  INTEGER as serialDteDTRAlarmStatus  
  DisplayString as serialDteStatusSummary  
  DisplayString as serialDteAlarmSummary  
  INTEGER as serialDteASCStatus  
  INTEGER as serialDteASCCount  
  INTEGER as serialDteASCThreshold  
  INTEGER as serialDteASCAlarm  
  INTEGER as serialDteFDLStatus  
  INTEGER as serialDteFDLCount  
  INTEGER as serialDteFDLThreshold  
  INTEGER as serialDteFDLAlarm  
  INTEGER as serialDteLOSStatus  
  INTEGER as serialDteLOSCount  
  INTEGER as serialDteLOSThreshold  
  INTEGER as serialDteLOSAlarm  

AnalogDteTableEntry  
SEQUENCE    
  INTEGER as analogDteNearIndex  
  INTEGER as analogDteFarIndex  
  INTEGER as analogDteIndex  
  DisplayString as analogDteDescription  
  INTEGER as analogDteCardType  
  INTEGER as analogDteMode  
  INTEGER as analogDteState  
  DisplayString as analogDteElementID  
  INTEGER as analogDteSignalling  
  INTEGER as analogDteDNISDelay  
  INTEGER as analogDteTxGain  
  INTEGER as analogDteRxGain  

ConnectionTableEntry  
SEQUENCE    
  INTEGER as connectionNearIndex  
  INTEGER as connectionFarIndex  
  INTEGER as connectionTableIndex  
  DisplayString as connectionTableDescription  

ConnectionChannelEntry  
SEQUENCE    
  INTEGER as connectionChannelNearIndex  
  INTEGER as connectionChannelFarIndex  
  INTEGER as connectionChannelLineIndex  
  INTEGER as connectionChannelIndex  
  INTEGER as channelInterfaceAssignment  
  DisplayString as channelInterfaceDescription  
  INTEGER as channelInterfaceChannel  
  INTEGER as channelSignalling  

BertTableEntry  
SEQUENCE    
  INTEGER as bertNearIndex  
  INTEGER as bertFarIndex  
  INTEGER as bertIndex  
  INTEGER as bertPattern  
  INTEGER as bertLength  
  INTEGER as bertPatternSync  
  INTEGER as bertElapsedTime  
  INTEGER as bertBitErrors  
  INTEGER as bertErroredSeconds  
  INTEGER as bertPercentEFS  
  INTEGER as bertCommand  

BertInterfaceTableEntry  
SEQUENCE    
  INTEGER as bertInterfaceNearIndex  
  INTEGER as bertInterfaceFarIndex  
  INTEGER as bertChipIndex  
  INTEGER as bertInterfaceIndex  
  INTEGER as bertInterfaceSetting  

TestTableEntry  
SEQUENCE    
  INTEGER as testNearIndex  
  INTEGER as testFarIndex  
  INTEGER as testTableIndex  
  INTEGER as testType  
  INTEGER as testLoopDirection  
  INTEGER as testFarLLBFraming  

Performance24TableEntry  
SEQUENCE    
  INTEGER as performance24NearIndex  
  INTEGER as performance24FarIndex  
  INTEGER as performance24InterfaceIndex  
  INTEGER as performance24Index  
  INTEGER as performance24ES  
  INTEGER as performance24BES  
  INTEGER as performance24SES  
  INTEGER as performance24UAS  
  INTEGER as performance24LOFC  
  INTEGER as performance24CSS  
  INTEGER as performance24CRCES  
  INTEGER as performance24OOFS  
  INTEGER as performance24LOSS  
  INTEGER as performance24AISS  
  INTEGER as performance24RAS  
  INTEGER as performance24BPVS  

Performance30TableEntry  
SEQUENCE    
  INTEGER as performance30NearIndex  
  INTEGER as performance30FarIndex  
  INTEGER as performance30InterfaceIndex  
  INTEGER as performance30Index  
  INTEGER as performance30ES  
  INTEGER as performance30BES  
  INTEGER as performance30SES  
  INTEGER as performance30UAS  
  INTEGER as performance30LOFC  
  INTEGER as performance30CSS  
  INTEGER as performance30CRCES  
  INTEGER as performance30OOFS  
  INTEGER as performance30LOSS  
  INTEGER as performance30AISS  
  INTEGER as performance30RAS  
  INTEGER as performance30BPVS  

ITableEntry  
SEQUENCE    
  INTEGER as iTableNearIndex  
  INTEGER as iTableFarIndex  
  INTEGER as iTableIndex  
  DisplayString as iDescription  
  INTEGER as iType  
  INTEGER as iSlot  
  INTEGER as iPort  
  INTEGER as iStatus  

TraplogEntry  
SEQUENCE    
  INTEGER as traplogIndex  
  INTEGER as traplogNearIndex  
  INTEGER as traplogFarIndex  
  INTEGER as traplogInterfaceIndex  
  INTEGER as traplogTrapNum  
  DisplayString as traplogTimeStamp  
  INTEGER as traplogDeviceType  

UnitUtilitiesTableEntry  
SEQUENCE    
  INTEGER as unitUtilitiesNearIndex  
  INTEGER as unitUtilitiesFarIndex  
  DisplayString as unitUtilitiesLocalPassword  
  DisplayString as unitUtilitiesTime  
  DisplayString as unitUtilitiesDate  
  INTEGER as unitUtilitiesMaintenanceReset  
  INTEGER as unitUtilitiesAlarmResetTimer  
  INTEGER as unitUtilitiesAlarmClear