JUNIPER-IF-MIB

File: JUNIPER-IF-MIB.mib (18002 bytes)

Imported modules

SNMPv2-SMI HCNUM-TC IF-MIB
SNMPv2-TC JUNIPER-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Gauge32
Integer32 Counter64 Counter32
CounterBasedGauge64 ifEntry ifIndex
TimeStamp jnxMibs

Defined Objects

ifJnx 1.3.6.1.4.1.2636.3.3
The MIB modules extends the ifTable as defined in IF-MIB.
MODULE-IDENTITY    

ifJnxTable 1.3.6.1.4.1.2636.3.3.1
A list of Juniper's extension to the interface entries. The number of entries is given by the value of ifNumber. This table contains additional objects for the interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    IfJnxEntry

ifJnxEntry 1.3.6.1.4.1.2636.3.3.1.1
An entry containing additional management information applicable to a particular interface.
OBJECT-TYPE    
  IfJnxEntry  

ifIn1SecRate 1.3.6.1.4.1.2636.3.3.1.1.1
The number of bits per second (bps), delivered by this (sub-)layer to its next higher (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifIn1SecOctets 1.3.6.1.4.1.2636.3.3.1.1.2
The number of octets per second (Bps, Bytes per second), delivered by this (sub-)layer to its next higher (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifIn1SecPkts 1.3.6.1.4.1.2636.3.3.1.1.3
The number of packets per second (pps), delivered by this (sub-)layer to its next higher (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifOut1SecRate 1.3.6.1.4.1.2636.3.3.1.1.4
The number of bits per second (bps), delivered by this (sub-)layer to its next lower (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifOut1SecOctets 1.3.6.1.4.1.2636.3.3.1.1.5
The number of octets per second (Bps, Bytes per second), delivered by this (sub-)layer to its next lower (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifOut1SecPkts 1.3.6.1.4.1.2636.3.3.1.1.6
The number of packets per second (pps), delivered by this (sub-)layer to its next lower (sub-)layer.
OBJECT-TYPE    
  Gauge32  

ifHCIn1SecRate 1.3.6.1.4.1.2636.3.3.1.1.7
The number of bits per second (bps), delivered by this (sub-)layer to its next higher (sub-)layer. This object is a 64 bit version of ifIn1SecRate.
OBJECT-TYPE    
  CounterBasedGauge64  

ifHCOut1SecRate 1.3.6.1.4.1.2636.3.3.1.1.8
The number of bits per second (bps), delivered by this (sub-)layer to its next lower (sub-)layer. This object is a 64 bit version of ifOut1SecRate.
OBJECT-TYPE    
  CounterBasedGauge64  

ifJnxInErrors 1.3.6.1.4.1.2636.3.3.1.1.9
Errors: The sum of the incoming frame aborts and FCS errors.
OBJECT-TYPE    
  Counter64  

ifJnxInFrameErrors 1.3.6.1.4.1.2636.3.3.1.1.10
Framing Errors: The number of input packets which were misaligned.
OBJECT-TYPE    
  Counter64  

ifJnxInQDrops 1.3.6.1.4.1.2636.3.3.1.1.11
Drops: The number of packets dropped by the input queue of the I/O Manager ASIC.
OBJECT-TYPE    
  Counter64  

ifJnxInRunts 1.3.6.1.4.1.2636.3.3.1.1.12
Runts: Frames received that are smaller than the runt threshold.
OBJECT-TYPE    
  Counter64  

ifJnxInGiants 1.3.6.1.4.1.2636.3.3.1.1.13
Giants: Frames received that are larger than the giant threshold.
OBJECT-TYPE    
  Counter64  

ifJnxInDiscards 1.3.6.1.4.1.2636.3.3.1.1.14
Policed Discards: Frames that the incoming packet match code discarded because they were not recognized or of interest.
OBJECT-TYPE    
  Counter64  

ifJnxInHslCrcErrors 1.3.6.1.4.1.2636.3.3.1.1.15
HS Link CRC Errors: The number of CRC errors on the high-speed links between the ASICs responsible for handling the router interfaces while receiving packets.
OBJECT-TYPE    
  Counter64  

ifJnxInHslFifoOverFlows 1.3.6.1.4.1.2636.3.3.1.1.16
HS link FIFO overflows: The number of FIFO overflows on the high-speed links between the ASICs responsible for handling the router interfaces.
OBJECT-TYPE    
  Counter64  

ifJnxInL3Incompletes 1.3.6.1.4.1.2636.3.3.1.1.17
L3 incompletes: The number of incoming packets that fail Layer 3 sanity checks of the header.
OBJECT-TYPE    
  Counter64  

ifJnxInL2ChanErrors 1.3.6.1.4.1.2636.3.3.1.1.18
L2 channel errors: the number of incoming packets for which the sofware could not find a valid logical interface.
OBJECT-TYPE    
  Counter64  

ifJnxInL2MismatchTimeouts 1.3.6.1.4.1.2636.3.3.1.1.19
L2 mismatch timeouts: The count of malformed or short packets that cause the incoming packet handler to discard the frame as unreadable.
OBJECT-TYPE    
  Counter64  

ifJnxInInvalidVCs 1.3.6.1.4.1.2636.3.3.1.1.20
Invalid VCs: Number of cells that arrived for a nonexistent virtual circuit.
OBJECT-TYPE    
  Counter64  

ifJnxInFifoErrors 1.3.6.1.4.1.2636.3.3.1.1.21
FIFO errors: The number of FIFO errors in the receive direction as reported by the ASIC on the PIC.
OBJECT-TYPE    
  Counter32  

ifJnxBucketDrops 1.3.6.1.4.1.2636.3.3.1.1.22
Bucket drops: Drops due to traffic load exceeding the interface transmit/receive leaky bucket configuration.
OBJECT-TYPE    
  Counter64  

ifJnxSramErrors 1.3.6.1.4.1.2636.3.3.1.1.23
SRAM errors: This counter increments when a hardware error has occurred in the SRAM on the PIC.
OBJECT-TYPE    
  Counter32  

ifJnxOutErrors 1.3.6.1.4.1.2636.3.3.1.1.24
Errors: The sum of the outgoing frame aborts and FCS errors.
OBJECT-TYPE    
  Counter64  

ifJnxCollisions 1.3.6.1.4.1.2636.3.3.1.1.25
Collisions: The number of output collisions detected on this interface.
OBJECT-TYPE    
  Counter64  

ifJnxCarrierTrans 1.3.6.1.4.1.2636.3.3.1.1.26
Carrier transitions: The number of times the interface saw the carrier signal transition.
OBJECT-TYPE    
  Counter64  

ifJnxOutQDrops 1.3.6.1.4.1.2636.3.3.1.1.27
Drops: The number of packets dropped by the output queue of the I/O Manager ASIC.
OBJECT-TYPE    
  Counter64  

ifJnxOutAgedErrors 1.3.6.1.4.1.2636.3.3.1.1.28
Aged packets: The number of packets that remained in shared packet SDRAM for so long that the system automatically purged them.
OBJECT-TYPE    
  Counter64  

ifJnxOutFifoErrors 1.3.6.1.4.1.2636.3.3.1.1.29
FIFO errors: The number of FIFO errors in the transmit direction as reported by the ASIC on the PIC.
OBJECT-TYPE    
  Counter32  

ifJnxOutHslFifoUnderFlows 1.3.6.1.4.1.2636.3.3.1.1.30
HS link FIFO underflows: The number of FIFO underflows on the high-speed links between the ASICs responsible for handling the router interfaces.
OBJECT-TYPE    
  Counter64  

ifJnxOutHslCrcErrors 1.3.6.1.4.1.2636.3.3.1.1.31
HS Link CRC Errors: The number of CRC errors on the high-speed links between the ASICs responsible for handling the router interfaces while transmitting packets.
OBJECT-TYPE    
  Counter32  

ifChassisTable 1.3.6.1.4.1.2636.3.3.2
A list of Juniper's extension to the interface entries. The number of entries is given by the value of ifNumber. This table contains additional objects for the interface table to facilitate the identification of interfaces and its mapping into the Chassis MIB tables.
OBJECT-TYPE    
  SEQUENCE OF  
    IfChassisEntry

ifChassisEntry 1.3.6.1.4.1.2636.3.3.2.1
An entry containing additional management information applicable to a particular interface.
OBJECT-TYPE    
  IfChassisEntry  

ifChassisFpc 1.3.6.1.4.1.2636.3.3.2.1.1
The number of the FPC card on which the interface is located in the chassis. It is the chassis slot in which the FPC card is installed for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical FPC associated with the specified interface.
OBJECT-TYPE    
  Integer32  

ifChassisPic 1.3.6.1.4.1.2636.3.3.2.1.2
The number of the PIC card on which the interface is located in the chassis. It is the PIC location on the FPC card for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical PIC associated with the specified interface.
OBJECT-TYPE    
  Integer32  

ifChassisPort 1.3.6.1.4.1.2636.3.3.2.1.3
The number of the port on the PIC card on which the interface is located in the chassis. It is the port number on the PIC card for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical port associated with the specified interface.
OBJECT-TYPE    
  Integer32  

ifChassisChannel 1.3.6.1.4.1.2636.3.3.2.1.4
The channel identifier for the specified interface if and only if it is part of a channelized interface. Although the channel is numbered from 0 and up in the interface naming, the return value for this object always starts from 1 according to Network Management convention. For the interface which could not be channelized, this object returns zero.
OBJECT-TYPE    
  Integer32  

ifChassisLogicalUnit 1.3.6.1.4.1.2636.3.3.2.1.5
The logical unit number of the specified interface. It is the logical part of the interface that is configured on the physical or channel part if any. Although the logical unit number is numbered from 0 and up in the interface naming, the return value for this object always starts from 1 according to Network Management convention. For the interface which is really a physical device, this value returns zero.
OBJECT-TYPE    
  Integer32  

ifChassisPicIndex 1.3.6.1.4.1.2636.3.3.2.1.6
The index or indices for the Chassis MIB tables. This is the instance index which keys into the jnxContentsTable in Chassis MIB. For example, it could return an octet string of '8.1.2.0' - meaning a PIC ('8', first digit) at FPC slot 0 ('1-1', second digit minus one if nonzero) PIC number 1 ('2-1', third digit minus one if nonzero) port number whatever (fourth digit currently unused) - which in turn could be plugged in by NMS directly after any MIB objects in the jnxContentsTable, say 'jnxContentsDescr.8.1.2.0', so NMS could get that PIC object for the specified interface. This object is valid only for those interfaces having real and physical PIC cards. Otherwise, it returns an octet string of four zeros '0.0.0.0.'
OBJECT-TYPE    
  OCTET STRING  

Defined Objects

IfJnxEntry  
SEQUENCE    
  Gauge32 as ifIn1SecRate  
  Gauge32 as ifIn1SecOctets  
  Gauge32 as ifIn1SecPkts  
  Gauge32 as ifOut1SecRate  
  Gauge32 as ifOut1SecOctets  
  Gauge32 as ifOut1SecPkts  
  CounterBasedGauge64 as ifHCIn1SecRate  
  CounterBasedGauge64 as ifHCOut1SecRate  
  Counter64 as ifJnxInErrors  
  Counter64 as ifJnxInFrameErrors  
  Counter64 as ifJnxInQDrops  
  Counter64 as ifJnxInRunts  
  Counter64 as ifJnxInGiants  
  Counter64 as ifJnxInDiscards  
  Counter64 as ifJnxInHslCrcErrors  
  Counter64 as ifJnxInHslFifoOverFlows  
  Counter64 as ifJnxInL3Incompletes  
  Counter64 as ifJnxInL2ChanErrors  
  Counter64 as ifJnxInL2MismatchTimeouts  
  Counter64 as ifJnxInInvalidVCs  
  Counter32 as ifJnxInFifoErrors  
  Counter64 as ifJnxBucketDrops  
  Counter32 as ifJnxSramErrors  
  Counter64 as ifJnxOutErrors  
  Counter64 as ifJnxCollisions  
  Counter64 as ifJnxCarrierTrans  
  Counter64 as ifJnxOutQDrops  
  Counter64 as ifJnxOutAgedErrors  
  Counter32 as ifJnxOutFifoErrors  
  Counter64 as ifJnxOutHslFifoUnderFlows  
  Counter32 as ifJnxOutHslCrcErrors  

IfChassisEntry  
SEQUENCE    
  Integer32 as ifChassisFpc  
  Integer32 as ifChassisPic  
  Integer32 as ifChassisPort  
  Integer32 as ifChassisChannel  
  Integer32 as ifChassisLogicalUnit  
  OCTET STRING as ifChassisPicIndex