Juniper-UNI-ATM-MIB

File: Juniper-UNI-ATM-MIB.mib (236592 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
SNMPv2-CONF IF-MIB ATM-TC-MIB
ATM-MIB ATM-FORUM-SNMP-M4-MIB Juniper-MIBs
Juniper-TC

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Integer32 Unsigned32
Counter64 Counter32 IpAddress
TimeTicks TEXTUAL-CONVENTION RowStatus
TruthValue TimeStamp DisplayString
SnmpAdminString MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP InterfaceIndex InterfaceIndexOrZero
ifIndex AtmVpIdentifier AtmVcIdentifier
AtmVorXAdminStatus AtmAddr atmVplVpi
atmVclVpi atmVclVci atmfM4VpTestObject
atmfM4VpTestId atmfM4VpTestType atmfM4VpTestResult
atmfM4VcTestObject atmfM4VcTestId atmfM4VcTestType
atmfM4VcTestResult atmfM4VpTestCode atmfM4VcTestCode
juniMibs JuniNextIfIndex JuniEnable
JuniInterfaceLocationType JuniInterfaceLocationValue

Defined Objects

juniAtmMIB 1.3.6.1.4.1.4874.2.2.8
The ATM MIB for the Juniper enterprise.
MODULE-IDENTITY    

juniAtmObjects 1.3.6.1.4.1.4874.2.2.8.1
OBJECT IDENTIFIER    

juniAtmIfLayer 1.3.6.1.4.1.4874.2.2.8.1.1
OBJECT IDENTIFIER    

juniAtmNextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.1
Coordinate ifIndex value allocation for entries in juniAtmIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmIfTable 1.3.6.1.4.1.4874.2.2.8.1.1.2
This table contains entries for ATM interfaces present in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfEntry

juniAtmIfEntry 1.3.6.1.4.1.4874.2.2.8.1.1.2.1
Each entry describes the characteristics of an ATM interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
OBJECT-TYPE    
  JuniAtmIfEntry  

juniAtmIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.1
The ifIndex of the ATM interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmNextIfIndex.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmIfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmIfRowStatus juniAtmIfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmIfIndex must have been determined previously, by reading juniAtmNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
OBJECT-TYPE    
  RowStatus  

juniAtmIfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.3
The ifIndex of an interface over which this ATM interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmIfIlmiVpi 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.4
The VPI of the ILMI of a major ATM interface.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfIlmiVci 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.5
The VCI of the ILMI of a major ATM interface.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfIlmiVcd 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.6
An integer identifier for the ILMI, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfIlmiPollFrequency 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.7
The amount of time in seconds between successive transmissions of ILMI messages on this interface for the purpose of detecting loss of ILMI connectivity. The distinguished value zero disables ILMI connectivity procedures on this interface.
OBJECT-TYPE    
  Integer32 0..65535  

juniAtmIfIlmiAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.8
The administrative status of ILMI in the ATM interface.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfUniVersion 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.9
Use to specify the User Network Interface (UNI) the router should use when ILMI link auto determination is unsuccesful or ILMI is disabled.
OBJECT-TYPE    
  INTEGER uniVersionAutoConfig(0), version3Dot0(1), version3Dot1(2), version4Dot0(3)  

juniAtmIfOamCellRxAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.10
Use to specify the OAM Cell Receive Administrative state on this interface.
OBJECT-TYPE    
  INTEGER oamCellAdminStateDisabled(0), oamCellAdminStateEnabled(1)  

juniAtmIfInCells 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.11
The total number of cells received on this major interface.
OBJECT-TYPE    
  Counter64  

juniAtmIfOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.12
The total number of cells transmitted on this major interface.
OBJECT-TYPE    
  Counter64  

juniAtmIfVcCount 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.13
The total number of circuits configured on this interface.
OBJECT-TYPE    
  Integer32 0..268431360  

juniAtmIfMapGroup 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.14
The NBMA map group this interface is associated with.
OBJECT-TYPE    
  JuniAtmNbmaMapNameOrNull  

juniAtmIfCacAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.15
The administrative staus of CAC on this ATM major interface.
OBJECT-TYPE    
  JuniEnable  

juniAtmIfCacUbrWeight 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.16
The bandwidth associated with every UBR and UBR with PCR connection configured on the ATM major interface. This value is used for CAC computation. The units are kilo-bits per second (kbps).
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacSubscriptionBandwidth 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.17
The subscribed bandwidth of the ATM major interface. If this value is not specified or set to 0, the effective port bandwidth is used. When a Get operation is performed the current effective bandwidth is returned. The units are kilo-bits per second (kbps).
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacAvailableBandwidth 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.18
The available bandwidth in Tx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacAvailableBandwidthRx 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.19
The available bandwidth in Rx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfE164Autoconversion 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.20
The status of E164 autoconversion feature in the ATM interface.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfE164Gateway 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.21
The status of E164 gateway feature in the ATM interface.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfE164OneToOneAddrTrans 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.22
The status of E164 one-to-one address translation feature in the ATM interface.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfOamCellFilter 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.23
The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards received OAM AIS and RDI cells. The value oamCellFilterAll discards all received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateEnabled, this object has no effect.
OBJECT-TYPE    
  INTEGER oamCellFilterAll(0), oamCellFilterAlarm(1)  

juniAtmIfCacUsedBandwidthUpper 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.24
The most significant 32 bits of the CAC used bandwidth on the ATM major interface. The least significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthLower.
OBJECT-TYPE    
  Unsigned32  

juniAtmIfCacUsedBandwidthLower 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.25
The least significant 32 bits of the CAC used bandwidth on the ATM major interface. The most significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthUpper.
OBJECT-TYPE    
  Unsigned32  

juniAtmIfAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.26
The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
OBJECT-TYPE    
  Unsigned32  

juniAtmPvcStatisticsTable 1.3.6.1.4.1.4874.2.2.8.1.1.3
This table contains statistics for PVC entries.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmPvcStatisticsEntry

juniAtmPvcStatisticsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.3.1
Each entry provides statistics on an ATM PVC.
OBJECT-TYPE    
  JuniAtmPvcStatisticsEntry  

juniAtmPvcStatsIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.1
The ifIndex of the ATM interface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmPvcStatsVpi 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.2
The VPI of the ATM VCC used by this ATM interface and PVC.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmPvcStatsVci 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.3
The VCI of the ATM VCC used by this ATM interface and PVC.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmPvcStatsInCells 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.4
Received cells.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInCellOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.5
Received cells octets.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInPackets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.6
Received AAL PDUs.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.7
Received AAL PDU octets.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.8
Transmitted cells.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutCellOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.9
Transmitted cell octets.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutPackets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.10
Transmitted AAL PDUs.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.11
Transmitted AAL PDU octets.
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInCellErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.12
Received cells dropped due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsinPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.13
Received packets dropped due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsOutCellErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.14
Cells not transmitted due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsOutPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.15
Packets not transmitted due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.16
Received packets w/o errors discarded.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketOctetDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.17
Received bytes w/o errors discarded.
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketUnknownProtocol 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.18
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
OBJECT-TYPE    
  Counter32  

juniAtmVpTunnelTable 1.3.6.1.4.1.4874.2.2.8.1.1.4
This table contains entries for ATM VP Tunnels present in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpTunnelEntry

juniAtmVpTunnelEntry 1.3.6.1.4.1.4874.2.2.8.1.1.4.1
Each entry describes the characteristics of an ATM VP Tunnel.
OBJECT-TYPE    
  JuniAtmVpTunnelEntry  

juniAtmVpTunnelIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.1
The ifIndex of the ATM interface. The value of this object is the same as the juniAtmIfIndex object in the juniAtmIfTable. Entries in this table cannot be created unless the underlying ATM interface entry is created first in the juniAtmIfTable.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVpTunnelVpi 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.2
The VPI value for this VP tunnel entry.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmVpTunnelKbps 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.3
The tunnel rate in kilobits per second (kbps) for this entry.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVpTunnelRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.4
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmVpTunnelRowStatus juniAtmVpTunnelKbps In addition, when creating an entry the following condition must hold: A correponding juniAtmVpTunnelIfIndex value must have been created in the juniAtmIfTable previously.
OBJECT-TYPE    
  RowStatus  

juniAtmVpTunnelServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.5
The ATM service category for the tunnel.
OBJECT-TYPE    
  INTEGER nrtVbr(1), cbr(2)  

juniAtmIfCapabilityTable 1.3.6.1.4.1.4874.2.2.8.1.1.5
This table contains entries for ATM interfaces present in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfCapabilityEntry

juniAtmIfCapabilityEntry 1.3.6.1.4.1.4874.2.2.8.1.1.5.1
Each entry describes the capabilities of an ATM interface. A management client can use this table to determine differences in the configurable level of support across entries in this table.
OBJECT-TYPE    
  JuniAtmIfCapabilityEntry  

juniAtmIfCapabilityIndex 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.1
The ifIndex of the ATM interface. The value of this object is the same as juniAtmIfIndex in the juniAtmIfTable.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmIfCapabilityTrafficShaping 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.2
Indicates whether traffic shaping is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
OBJECT-TYPE    
  TruthValue  

juniAtmIfCapabilityOam 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.3
Indicates whether OAM is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
OBJECT-TYPE    
  TruthValue  

juniAtmIfCapabilityDefaultVcPerVp 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.4
The default number of VCs per VP for this interface.
OBJECT-TYPE    
  Integer32 0..65536  

juniAtmIfCapabilityNumVpiVciBits 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.5
The total range of bits used for constructing VPI/VCI identifiers for this interface.
OBJECT-TYPE    
  Integer32 8..28  

juniAtmIfCapabilityMaxVcd 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.6
The maximum configurable value for a VCD on this interface.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCapabilityMaxVpi 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.7
The maximum configurable value for a VPI on this interface.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfCapabilityMaxVci 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.8
The maximum configurable value for a VCI on this interface.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfCapabilityOamCellFilter 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.9
Indicates whether OAM cell filter is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
OBJECT-TYPE    
  TruthValue  

juniAtmIfSvcSignallingTable 1.3.6.1.4.1.4874.2.2.8.1.1.6
This table contains entries for extending the juniAtmIfTable for configuring signalling information for switched virtual connection (SVC).
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfSvcSignallingEntry

juniAtmIfSvcSignallingEntry 1.3.6.1.4.1.4874.2.2.8.1.1.6.1
Each entry provides configuration parameters for ATM signalling on the interface.
OBJECT-TYPE    
  JuniAtmIfSvcSignallingEntry  

juniAtmIfSvcSignallingVpi 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.1
The VPI identifier of the ATM circuit used for signalling for this interface.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfSvcSignallingVci 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.2
The VCI identifier of the ATM circuit used for signalling for this interface.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfSvcSignallingVcd 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.3
An integer identifier for the ATM circuit used for signalling on this interface.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfSvcSignallingAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.4
The administrative status of signalling on the ATM interface.
OBJECT-TYPE    
  AtmVorXAdminStatus  

juniAtmIfPnniRccTable 1.3.6.1.4.1.4874.2.2.8.1.1.7
This table contains entries for extending the juniAtmIfTable for configuring PNNI RCC information.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfPnniRccEntry

juniAtmIfPnniRccEntry 1.3.6.1.4.1.4874.2.2.8.1.1.7.1
Each entry provides configuration parameters for PNNI RCC on the interface.
OBJECT-TYPE    
  JuniAtmIfPnniRccEntry  

juniAtmIfPnniRccVpi 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.1
The VPI identifier of the ATM circuit used for PNNI RCC on this interface.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfPnniRccVci 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.2
The VCI identifier of the ATM circuit used for PNNI RCC on this interface.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfPnniRccVcd 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.3
An integer identifier for the ATM circuit used for PNNI RCC on this interface.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfPnniRccAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.4
The administrative status of PNNI on the ATM interface.
OBJECT-TYPE    
  AtmVorXAdminStatus  

juniAtmOamF4FlowEndToEndCfgTable 1.3.6.1.4.1.4874.2.2.8.1.1.8
This table contains entries for F4 OAM end-to-end flows configured.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmOamF4FlowEndToEndCfgEntry

juniAtmOamF4FlowEndToEndCfgEntry 1.3.6.1.4.1.4874.2.2.8.1.1.8.1
Each entry provides configuration parameters for one F4 OAM end-to-end flow configured for each VPI.
OBJECT-TYPE    
  JuniAtmOamF4FlowEndToEndCfgEntry  

juniAtmOamF4FlowEndToEndIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.1
The ifIndex of the ATM interface to configure the F4 OAM end-to-end flow.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmOamF4FlowEndToEndVpi 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.2
Select the VPI for F4 OAM end-to-end flow configuration.
OBJECT-TYPE    
  Integer32 0..255  

juniAtmOamF4FlowEndToEndLoopbackTimer 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.3
Configure the timer for sending the F4 flow end-to-end loopback OAM cells. Setting this value will enable sending the F4 end cells on the circuit. It is not allowed to set the value to -1 and whenever it is read as -1 that means sending end loopback is not enabled. Setting the loopback timer, other than -1, will enable sending the end cells.
OBJECT-TYPE    
  Integer32 -1..600  

juniAtmOamF4FlowEndToEndCCSink 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.4
Enable/Disable F4 flow end-to-end continuity check sink end point for this VP.
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowEndToEndCCSource 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.5
Enable/Disable F4 flow end-to-end continuity check source end point for this VP.
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowEndToEndRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.6
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowEndToEndRowStatus F4 OAM end loopback and CC tests are mutually exclusive, enabling one will disable the other automatically. So, it is not allowed either at the circuit creation time or after the circuit creation to issue a request to enable end-to-end loopback and CC tests simultaneouly. Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous.
OBJECT-TYPE    
  RowStatus  

juniAtmOamF4FlowSegmentCfgTable 1.3.6.1.4.1.4874.2.2.8.1.1.9
This table contains entries for F4 OAM Segment flows configured.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmOamF4FlowSegmentCfgEntry

juniAtmOamF4FlowSegmentCfgEntry 1.3.6.1.4.1.4874.2.2.8.1.1.9.1
Each entry provides configuration parameters for one F4 OAM Segment flow configured for each VPI.
OBJECT-TYPE    
  JuniAtmOamF4FlowSegmentCfgEntry  

juniAtmOamF4FlowSegmentIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.1
The ifIndex of the ATM interface to configure the F4 OAM segment flow.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmOamF4FlowSegmentVpi 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.2
Select the VPI for F4 OAM segment flow configuration.
OBJECT-TYPE    
  Integer32 0..255  

juniAtmOamF4FlowSegmentCCSink 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.3
Enable/Disable F4 flow segment continuity check sink end point for this VP.
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowSegmentCCSource 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.4
Enable/Disable F4 flow segment continuity check source end point for this VP.
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowSegmentRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.5
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowSegmentRowStatus Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous. F4 OAM segment loopback test is not supported.
OBJECT-TYPE    
  RowStatus  

juniAtmVpDescrTable 1.3.6.1.4.1.4874.2.2.8.1.1.10
This table contains entries for ATM VP Description present in the system. The user can configure a description of up to 32 characters for every VP in the ATM interface. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpDescrEntry

juniAtmVpDescrEntry 1.3.6.1.4.1.4874.2.2.8.1.1.10.1
Each entry contains the description of the VP.
OBJECT-TYPE    
  JuniAtmVpDescrEntry  

juniAtmVpDescription 1.3.6.1.4.1.4874.2.2.8.1.1.10.1.1
The description for this VP. The default value of this object is null string.
OBJECT-TYPE    
  SnmpAdminString SIZE(0..32)  

juniAtmF4FlowOamEndToEndStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.11
This table contains entries for F4 flow EndToEnd OAM circuits stats.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmF4FlowOamEndToEndStatsEntry

juniAtmF4FlowOamEndToEndStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.11.1
Each entry provides stats for one F4 OAM circuit for each VPI.
OBJECT-TYPE    
  JuniAtmF4FlowOamEndToEndStatsEntry  

juniAtmF4FlowInOamEndAisCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.1
Received end-to-end OAM F4 AIS cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.2
Received end-to-end OAM F4 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.3
Received end-to-end OAM F4 CC cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.4
Received end-to-end OAM F4 activation/de-activation cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.5
Total received OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndInLoopbackCmds and juniAtmF4FlowEndToEndInLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.6
Transmitted end-to-end OAM F4 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.7
Transmitted end-to-end OAM F4 CC cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.8
Transmitted end-to-end OAM F4 activation/de-activation cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.9
Total transmitted OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndOutLoopbackCmds and juniAtmF4FlowEndToEndOutLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndActualLoopbackFreq 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.10
Actual end-to-end loopback Frequecy calculated for OAM cells transmission.
OBJECT-TYPE    
  Integer32 0..65535  

juniAtmF4FlowEndLastTimeChanged 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.11
Last time end-to-end F4 OAM flow got changed.
OBJECT-TYPE    
  TimeTicks  

juniAtmF4FlowOamEndVpOperationState 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.12
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
OBJECT-TYPE    
  INTEGER vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)  

juniAtmF4FlowOamEndVpAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.13
End-to-end VP admin state.
OBJECT-TYPE    
  INTEGER down(0), up(1)  

juniAtmF4FlowEndInOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.14
Received end-to-end OAM F4 loopback cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndOutOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.15
Transmitted end-to-end OAM F4 loopback cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.16
Received end-to-end OAM cells that were dropped.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndInLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.17
Received OAM F4 end-to-end loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndInLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.18
Received OAM F4 end-to-end loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndOutLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.19
Transmitted OAM F4 end-to-end loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndOutLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.20
Transmitted OAM F4 end-to-end loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOamSegmentStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.12
This table contains entries for F4 flow Segment OAM circuits stats.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmF4FlowOamSegmentStatsEntry

juniAtmF4FlowOamSegmentStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.12.1
Each entry provides stats for one F4 OAM circuit for each VPI.
OBJECT-TYPE    
  JuniAtmF4FlowOamSegmentStatsEntry  

juniAtmF4FlowInOamSegmentAisCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.1
Received end-to-end OAM F4 AIS cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.2
Received end-to-end OAM F4 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.3
Received end-to-end OAM F4 CC cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.4
Received end-to-end OAM F4 activation/de-activation cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.5
Total received OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentInLoopbackCmds and juniAtmF4FlowSegmentInLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.6
Transmitted end-to-end OAM F4 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.7
Transmitted end-to-end OAM F4 CC cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.8
Transmitted end-to-end OAM F4 activation/de-activation cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.9
Total transmitted OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentOutLoopbackCmds and juniAtmF4FlowSegmentOutLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentLastTimeChanged 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.10
Last time end-to-end F4 OAM flow got changed.
OBJECT-TYPE    
  TimeTicks  

juniAtmF4FlowOamSegmentVpOperationState 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.11
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
OBJECT-TYPE    
  INTEGER vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)  

juniAtmF4FlowOamSegmentVpAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.12
Segment VP admin state.
OBJECT-TYPE    
  INTEGER down(0), up(1)  

juniAtmF4FlowSegmentInOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.13
Received end-to-end OAM F4 loopback cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.14
Transmitted end-to-end OAM F4 loopback cells.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.15
Received end-to-end OAM cells that were dropped.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.16
Received OAM F4 segment loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.17
Received OAM F4 segment loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.18
Transmitted OAM F4 segment loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.19
Transmitted OAM F4 segment loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmMartiniTimeoutTimerTable 1.3.6.1.4.1.4874.2.2.8.1.1.13
This table contains entries for ATM Martini cell aggregation timeout detection. The user can configure timeout values for three timers. A row exists for every separate timer supported. These rows get created as soon as the ERX system comes up.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmMartiniTimeoutTimerEntry

juniAtmMartiniTimeoutTimerEntry 1.3.6.1.4.1.4874.2.2.8.1.1.13.1
Each entry contains the timeout value of ATM Martini cell aggregation timer.
OBJECT-TYPE    
  JuniAtmMartiniTimeoutTimerEntry  

juniAtmMartiniTimeoutTimerIndex 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.1
The ATM Martini cell aggregation timeout timer identifier.
OBJECT-TYPE    
  INTEGER timer1(1), timer2(2), timer3(3)  

juniAtmMartiniTimeoutTimerValue 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.2
The ATM Martini cell aggregation timeout timer value in microseconds.
OBJECT-TYPE    
  Integer32 100..4095  

juniAtmVpStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.14
This table contains entries for ATM VP statistics present in the system. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpStatsEntry

juniAtmVpStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.14.1
Each entry contain the VP statistics.
OBJECT-TYPE    
  JuniAtmVpStatsEntry  

juniAtmVpStatsIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.1
The ifIndex of the ATM interface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVpStatsVpi 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.2
The VPI value of the virtual path for which statistics are retrieved.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmVpStatsInCells 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.3
Received cells.
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.4
Received AAL5 PDUs.
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.5
Received AAL5 PDU octets.
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.6
Transmitted cells.
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.7
Transmitted AAL5 PDUs
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.8
Transmitted AAL5 PDU octets.
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.9
Received packets dropped due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsOutPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.10
Packets not transmitted due to errors.
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.11
Received packets without errors discarded.
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketOctetDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.12
Received bytes without errors discarded.
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketUnknownProtocol 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.13
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsCrcErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.14
Received packets that are discarded because of check sum erros
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsSarTimeouts 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.15
Received packets that are discarded because of SAR timeout
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsOverSizedPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.16
Over sized packets that are received on this VP.
OBJECT-TYPE    
  Counter32  

juniAtmAal5IfLayer 1.3.6.1.4.1.4874.2.2.8.1.2
OBJECT IDENTIFIER    

juniAtmAal5NextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.1
Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmAal5IfTable 1.3.6.1.4.1.4874.2.2.8.1.2.2
This table contains entries for ATM AAL5 interfaces present in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmAal5IfEntry

juniAtmAal5IfEntry 1.3.6.1.4.1.4874.2.2.8.1.2.2.1
Each entry describes the characteristics of an ATM AAL5 interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
OBJECT-TYPE    
  JuniAtmAal5IfEntry  

juniAtmAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.1
The ifIndex of the ATM AAL5 interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmAal5NextIfIndex.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmAal5IfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmAal5IfRowStatus juniAtmAal5IfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmAal5IfIndex must have been determined previously, by reading juniAtmAal5NextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
OBJECT-TYPE    
  RowStatus  

juniAtmAal5IfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.3
The ifIndex of an ATM interface over which this ATM AAL5 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmBulkCircuitsNameTable 1.3.6.1.4.1.4874.2.2.8.1.2.3
The entries in this table provide mappings of ATM bulk virtual circuit range names to local integer identifiers for those profiles. These integers are used as indexes into other MIB tables containing profile configuration parameters associated with the same profile name.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsNameEntry

juniAtmBulkCircuitsNameEntry 1.3.6.1.4.1.4874.2.2.8.1.2.3.1
A mapping of a ATM bulk virtual circuit range name to an integer identifier for that name.
OBJECT-TYPE    
  JuniAtmBulkCircuitsNameEntry  

juniAtmBulkCircuitsNameAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.1
The ifIndex of the ATM AAL5 interface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsNameName 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.2
The ATM bulk virtual circuit range name uniquely identifying this entry.
OBJECT-TYPE    
  DisplayString SIZE(1..80)  

juniAtmBulkCircuitsNameRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.3
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Creating an entry in this table creates corresponding entry in juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes corresponding entries in juniAtmBulkCircuitsIdTable, juniAtmBulkCircuitsTable and juniAtmProfileOverrideAssignIfCircuitTable.
OBJECT-TYPE    
  RowStatus  

juniAtmBulkCircuitsNameId 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.4
The integer identifier associated with this ATM bulk virtual circuit range name. This value of this identifier is assigned by the device when an entry in this table is created.
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsIdTable 1.3.6.1.4.1.4874.2.2.8.1.2.4
Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk virtual circuit names.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsIdEntry

juniAtmBulkCircuitsIdEntry 1.3.6.1.4.1.4874.2.2.8.1.2.4.1
A mapping of an integer identifier to a ATM bulk virtual circuit name.
OBJECT-TYPE    
  JuniAtmBulkCircuitsIdEntry  

juniAtmBulkCircuitsIdAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.1
The ifIndex of the ATM AAL5 interface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsIdId 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.2
The integer identifier associated with this ATM bulk virtual circuit name.
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsIdName 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.3
The ATM bulk virtual circuit name having the associated identifier.
OBJECT-TYPE    
  DisplayString SIZE(1..80)  

juniAtmBulkCircuitsIdNextInstance 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.4
The next available instance value for juniAtmBulkCircuitsEntry.
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsTable 1.3.6.1.4.1.4874.2.2.8.1.2.5
This table contains bulk virtual circuit range parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsEntry

juniAtmBulkCircuitsEntry 1.3.6.1.4.1.4874.2.2.8.1.2.5.1
Each entry describes the characteristics of VC range.
OBJECT-TYPE    
  JuniAtmBulkCircuitsEntry  

juniAtmBulkCircuitsAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.1
The ifIndex of the ATM AAL5 interface on which this bulk virtual circuit sub-range is created.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsId 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.2
The integer identifier associated with this ATM bulk virtual circuit name.
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsInstance 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.3
The unique identifier of the ATM bulk virtual circuit sub-range.
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since none of the VPI/VCI minimum and maximum values have default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI/VCI minimum and maximum values can only be configured upon creation. Deleting an entry in this table deletes corresponding entries in juniAtmProfileOverrideAssignIfCircuitTable.
OBJECT-TYPE    
  RowStatus  

juniAtmBulkCircuitsMinVpi 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.5
The minimum value of VPI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVpi.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmBulkCircuitsMaxVpi 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.6
The maximum value of VPI for this cicuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVpi.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmBulkCircuitsMinVci 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.7
The minimum value of VCI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVci.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmBulkCircuitsMaxVci 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.8
The maximum value of VCI for this circuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVci.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmBulkCircuitsAdminState 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.9
The administrative status of this circuit sub-range.
OBJECT-TYPE    
  JuniEnable  

juniAtmProfileOverrideAssignIfCircuitTable 1.3.6.1.4.1.4874.2.2.8.1.2.6
Table providing overriding profile assignment to a circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci. The entries in this table specify which profile to use when creating and configuring a dynamic interface above a circuit specified by vpi and vci. This entry is effective when the circuit specified by juniAtmProfileOverrideAssignIfCircuitAal5Index, juniAtmProfileOverrideAssignIfCircuitRangeId, juniAtmProfileOverrideAssignIfCircuitVpi, juniAtmProfileOverrideAssignIfCircuitVci is part of bulk-configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmProfileOverrideAssignIfCircuitEntry

juniAtmProfileOverrideAssignIfCircuitEntry 1.3.6.1.4.1.4874.2.2.8.1.2.6.1
An assignment of a profile to a circuit configured as part of bulk-configuration on an AAL5 interface.
OBJECT-TYPE    
  JuniAtmProfileOverrideAssignIfCircuitEntry  

juniAtmProfileOverrideAssignIfCircuitAal5Index 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.1
The ifIndex of the AAL5 interface to which the profile is assigned.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmProfileOverrideAssignIfCircuitRangeId 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.2
The integer identifier associated with the ATM bulk circuit configuration.
OBJECT-TYPE    
  Unsigned32  

juniAtmProfileOverrideAssignIfCircuitVpi 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.3
The VPI value of the circuit to which the profile is assigned.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmProfileOverrideAssignIfCircuitVci 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.4
The VCI value of the circuit to which the profile is assigned.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmProfileOverrideAssignIfCircuitRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.5
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since the VPI, VCI and profileId values do not have any default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI, VCI and profileId values can only be configured upon creation. None of these values can be modified except by deleting the entry.
OBJECT-TYPE    
  RowStatus  

juniAtmProfileOverrideAssignIfCircuitProfileId 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.6
The ID of the profile assigned to the circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci.
OBJECT-TYPE    
  Unsigned32  

juniAtmProfileOverrideAssignIfCircuitOperStatus 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.7
The operational status of the profile override assignment identified by this entry. It returns inactive(0), if a static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will not be used to configure upper dynamic interfaces. It returns active(1), if no static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will be used to configure upper dynamic interfaces.
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

juniAtmSubIfLayer 1.3.6.1.4.1.4874.2.2.8.1.3
OBJECT IDENTIFIER    

juniAtmSubIfNextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.1
Coordinate ifIndex value allocation for entries in juniAtmSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmSubIfTable 1.3.6.1.4.1.4874.2.2.8.1.3.2
This table contains entries for ATM Subinterfaces present in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfEntry

juniAtmSubIfEntry 1.3.6.1.4.1.4874.2.2.8.1.3.2.1
Each entry describes the characteristics of an ATM Subinterface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
OBJECT-TYPE    
  JuniAtmSubIfEntry  

juniAtmSubIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.1
The ifIndex of the ATM Subinterface. When creating entries in this table, suitable values for this object are determined by reading juniAtmSubNextIfIndex.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmSubIfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfRowStatus juniAtmSubIfLowerIndex In addition, when creating an entry the following condition must hold: A value for juniAtmSubIfIndex must have been determined previously, by reading juniAtmSubIfNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfDistinguisher 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.3
An integer identifier for the subinterface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among subinterfaces configured on the same underlying ATM adaptation layer. The upper bound for the value is further constrained to be identical with the maximum number of subinterfaces supported by the lower interface. If this object is not configured, a value will be allocated internally and can be queried after table entry creation has succeeded.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.4
The ifIndex of an ATM AAL5 interface over which this ATM subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmSubIfNbma 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.5
The NBMA administrative setting. Setting this value of this object to true(1) will enable multipoint access on this interface. Setting the value to false(2), will enable point to point access on this interface.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfAddress 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.6
Specifies the local ATM NSAP address of the circuit. A GET operation returns a full 20-octet NSAP. A SET operation only requires 7 octets, since the prefix can be implied.
OBJECT-TYPE    
  AtmAddr SIZE(0 | 7 | 20)  

juniAtmSubIfMtu 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.7
The size of the largest packet which can be sent/received on the interface, specified in octets.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfAdvisoryRxSpeed 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.8
Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for underlying circuit receive speed.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfMartiniMaxCellsPerPacket 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.9
The number of cells that can be aggregated in a single ATM Martini packet in cell-relay mode.
OBJECT-TYPE    
  Integer32 1..190  

juniAtmSubIfMartiniTimeoutTimerId 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.10
The timer identifier used to abandon cell aggregation when no cells are supplied for transmission in ATM Martini cell-relay mode.
OBJECT-TYPE    
  Integer32 1..3  

juniAtmSubIfAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.11
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfVccTable 1.3.6.1.4.1.4874.2.2.8.1.3.3
This table contains entries for ATM VCCs configured on ATM subinterfaces present in the system. An implementation may constrain the number of VCCs permitted to be configured per ATM Subinterface; in particular, an implementation may restrict each ATM Subinterface to have a single VCC. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfVccEntry

juniAtmSubIfVccEntry 1.3.6.1.4.1.4874.2.2.8.1.3.3.1
Each entry describes the characteristics of an ATM subinterface VCC.
OBJECT-TYPE    
  JuniAtmSubIfVccEntry  

juniAtmSubIfVccVpi 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.1
The VPI of the ATM VCC used by this subinterface.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmSubIfVccVci 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.2
The VCI of the ATM VCC used by this subinterface.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmSubIfVccRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.3
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfVccRowStatus In addition, when creating an entry the following conditions must hold: The ATM Subinterface identified by juniAtmSubIfIndex must exist. A positive value configured for juniAtmSubIfVccVcd must not already be assigned to an existing VCC. For each value of juniAtmSubIfVccServiceCategory, additional dependent objects in the entry require configuration as identified here: juniAtmSubIfVccServiceCategory Requires configuration of: ------------------------------------------------------------ ubr ubrPcr juniAtmSubIfVccPcr nrtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs cbr juniAtmSubIfVccPcr rtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs ------------------------------------------------------------ Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfVccVcd 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.4
An integer identifier for the circuit, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among VCCs configured on the same underlying ATM interface. If this object is not configured, or is configured with a value of zero, a value will be allocated internally and can be queried after table entry creation has succeeded.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccType 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.5
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VcMux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)  

juniAtmSubIfVccServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.6
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmSubIfVccPcr 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.7
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccScr 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.8
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccMbs 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.9
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
OBJECT-TYPE    
  Integer32 0..16777215  

juniAtmSubIfInverseArp 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.10
Enables the inverse ARP protocol on this VCC; true(1) enables the protocol, false(2) disables it.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfInverseArpRefresh 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.11
The refresh rate in minutes between inverse ARP protocol messages.
OBJECT-TYPE    
  Integer32 0..60  

juniAtmSubIfVccAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.12
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this VC.
OBJECT-TYPE    
  Unsigned32  

juniAtmCircuitOamTable 1.3.6.1.4.1.4874.2.2.8.1.3.4
This table contains circuit OAM data for a PVC.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmCircuitOamEntry

juniAtmCircuitOamEntry 1.3.6.1.4.1.4874.2.2.8.1.3.4.1
Each entry provides OAM data on an ATM PVC.
OBJECT-TYPE    
  JuniAtmCircuitOamEntry  

juniAtmCircuitOamIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.1
The ifIndex of the ATM subinterface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmCircuitOamVpi 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.2
The VPI of the ATM VCC used by this ATM interface and PVC.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmCircuitOamVci 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.3
The VCI of the ATM VCC used by this ATM interface and PVC.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmCircuitOamAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.4
The administrative state of OAM for the interface identified by this entry.
OBJECT-TYPE    
  INTEGER oamAdminStateDisabled(1), oamAdminStateEnabled(2)  

juniAtmCircuitOamLoopbackOperStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.5
The operational status of OAM for the interface identified by this entry. oamOperStatusNotSupported(0) - OAM not supported on this interface oamOperStatusDisabled(1) - VC integrity disabled oamOperStatusSent(2) - Loopback sent, awaiting response oamOperStatusReceived(3) - Loopback response received, awaiting frequency oamOperStatusFailed(4) - Loopback response not received, or invalid response received
OBJECT-TYPE    
  INTEGER oamOperStatusNotSupported(0), oamOperStatusDisabled(1), oamOperStatusSent(2), oamOperStatusReceived(3), oamOperStatusFailed(4)  

juniAtmCircuitVcOamOperStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.6
The OAM VC operational status of this entry. oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS oamVcOperStateRdiState(1) - RDI cell received oamVcOperStateDownRetry(2) - OAM loopback failed, using retry frequency to verify that the VC is really down oamVcOperStateUpRetry(3) - OAM loopback successful, using retry frequency to verify that the VC is really up oamVcOperStateUp(4) - OAM loopback successful after up retry verification oamVcOperStateDown(5) - OAM loopback failed after down retry verification oamVcOperStateNotManaged(6)- No verification via loopback cells being performed oamVcOperStateVpAis(7) - F4 AIS cell received oamVcOperStateVpRdi(8) - F4 RDI cell received oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure oamVcOperStateSegAis(11) - Segment AIS cell received oamVcOperStateSegRdi(12) - Segment RDI cell received oamVcOperStateGenAis(13) - Connection failure; generating AIS cells.
OBJECT-TYPE    
  INTEGER oamVcOperStateAisState(0), oamVcOperStateRdiState(1), oamVcOperStateDownRetry(2), oamVcOperStateUpRetry(3), oamVcOperStateUp(4), oamVcOperStateDown(5), oamVcOperStateNotManaged(6), oamVcOperStateVpAis(7), oamVcOperStateVpRdi(8), oamVcOperStateVcInVpRdi(9), oamVcoperStateVcInVpAis(10), oamVcOperStateSegAis(11), oamVcOperStateSegRdi(12), oamVcOperStateGenAis(13)  

juniAtmCircuitOamLoopbackFrequency 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.7
The OAM loopback frequency in seconds.
OBJECT-TYPE    
  Integer32 1..600  

juniAtmCircuitInOamF5Cells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.8
Received OAM F5 cells.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.9
Received OAM cells that were dropped.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5Cells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.10
Transmitted OAM F5 cells.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.11
Total received OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitInOamF5EndToEndLoopbackCmds and juniAtmCircuitInOamF5EndToEndLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.12
Total received OAM F5 segment loopback cells. Aggregate of juniAtmCircuitInOamF5SegmentLoopbackCmds and juniAtmCircuitInOamF5SegmentLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5AisCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.13
Received OAM F5 AIS cells.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5RdiCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.14
Received OAM F5 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.15
Total transmitted OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitOutOamF5EndToEndLoopbackCmds and juniAtmCircuitOutOamF5EndToEndLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.16
Total transmitted OAM F5 segment loopback cells. Aggregate of juniAtmCircuitOutOamF5SegmentLoopbackCmds and juniAtmCircuitOutOamF5SegmentLoopbackRsps
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5RdiCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.17
Transmitted OAM F5 RDI cells.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.18
Received OAM F5 end-to-end loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.19
Received OAM F5 end-to-end loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.20
Received OAM F5 segment loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.21
Received OAM F5 segment loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.22
Transmitted OAM F5 end-to-end loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.23
Transmitted OAM F5 end-to-end loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.24
Transmitted OAM F5 segment loopback commands.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.25
Transmitted OAM F5 segment loopback responses.
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOamUpCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.26
Specifies the number of successive loopback cell responses to receive before a PVC is up for connectivity verification.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamDownCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.27
Specifies the number of successive loopback cell responses not received before declaring a PVC down for connectivity verification.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamRetryFrequency 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.28
Specifies the frequency (in seconds) to transmit loopback cells when verifying PVC state (up or down) for connectivity verification.
OBJECT-TYPE    
  Integer32 1..600  

juniAtmCircuitOamAlarmDownCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.29
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring a PVC down.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamAlarmClearTimeout 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.30
Specifies how long to wait (in seconds) before declaring a PVC up after it has stopped receiving alarm cells.
OBJECT-TYPE    
  Integer32 3..60  

juniAtmSubIfVccTrafficShapingTable 1.3.6.1.4.1.4874.2.2.8.1.3.5
This table contains entries for traffic shaping of ATM VCCs configured on ATM subinterfaces present in the system. This table augments the juniAtmSubIfVccTable only for VCCs that support traffic shapping. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfVccTrafficShapingEntry

juniAtmSubIfVccTrafficShapingEntry 1.3.6.1.4.1.4874.2.2.8.1.3.5.1
Each entry describes the traffic shping characteristics of an ATM subinterface VCC.
OBJECT-TYPE    
  JuniAtmSubIfVccTrafficShapingEntry  

juniAtmSubIfVccTrafficShapingCdvt 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.1
The network cell delay variation tolerance (CDVT) in tenths of a microsecond.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfVccTrafficShapingClp0 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.2
Specifies whether or not only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only for VBR circuits.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingTagging 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.3
Specifies whether or not CLP0 cells should be tagged for SCR policing (VBR.3 conformance). Applicable only for VBR circuits.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingPoliceObserve 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.4
Specifies whether of not no policing action is to be taken (note the double negative; if true(1) then no policing action will be taken; if false(2) then policing action will be taken). Regardless of the state of this object, all counters will be incremented.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingPacketShaping 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.5
Specifies whether of not to shape output traffic on a packet boundary.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigTable 1.3.6.1.4.1.4874.2.2.8.1.3.6
This table contains entries for extending the juniAtmSubIfTable to configure switched virtual connection (SVC) on the subinterfaces.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfSvcConfigEntry

juniAtmSubIfSvcConfigEntry 1.3.6.1.4.1.4874.2.2.8.1.3.6.1
Each entry provides configuration parameters for an ATM SVC on the subinterface.
OBJECT-TYPE    
  JuniAtmSubIfSvcConfigEntry  

juniAtmSubIfSvcRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.1
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfSvcConfigDestAtmAddress 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.2
Specifies the destination ATM NSAP address of the circuit.
OBJECT-TYPE    
  AtmAddr SIZE(20)  

juniAtmSubIfSvcConfigCircuitType 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.3
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM.
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1)  

juniAtmSubIfSvcConfigServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.4
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmSubIfSvcConfigPcr 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.5
Peak Cell Rate, in kilo-bits per second (kbps), of this circuit.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigScr 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.6
Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigMbs 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.7
Maximum Burst Size, in cells, of this circuit.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigCdvt 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.8
Specify the network Cell Delay Variation Tolerance.
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigClp0 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.9
Specify that only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance).
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigTagging 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.10
Specify that CLP0 cells should be tagged for SCR policing (VBR.3 conformance).
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigObserve 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.11
Specify that no policing action is to be taken; only counters are incremented.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigPacketDiscard 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.12
Enable early packet Discard for this circuit.
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigDestE164Address 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.13
Specifies the destination ATM E164 address of the circuit.
OBJECT-TYPE    
  AtmAddr SIZE(0 | 8)  

juniAtmSubIfDescriptionExport 1.3.6.1.4.1.4874.2.2.8.1.3.7
Enabling of this object will program the subinterface description down to the applicable line card. Note, the subinterface description sent down to the line card is a truncated version (32 bytes) of the ifAlias.
OBJECT-TYPE    
  TruthValue  

juniAtmNbma 1.3.6.1.4.1.4874.2.2.8.1.4
OBJECT IDENTIFIER    

juniAtmNbmaMapTable 1.3.6.1.4.1.4874.2.2.8.1.4.1
This table contains entries for ATM NBMA maps.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmNbmaMapEntry

juniAtmNbmaMapEntry 1.3.6.1.4.1.4874.2.2.8.1.4.1.1
Each entry describes the characteristics of an ATM NBMA map.
OBJECT-TYPE    
  JuniAtmNbmaMapEntry  

juniAtmNbmaMapName 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.1
The NBMA map name.
OBJECT-TYPE    
  JuniAtmNbmaMapName  

juniAtmNbmaMapVcd 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.2
An integer identifier for the ATM circuit, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmNbmaMapIpAddress 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.3
The IP address associated with this entry.
OBJECT-TYPE    
  IpAddress  

juniAtmNbmaMapVpi 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.4
The VPI identifier of the ATM circuit.
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmNbmaMapVci 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.5
The VCI identifier of the ATM circuit.
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmNbmaMapIfIndex 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.6
The ifIndex of the ATM major interface associated with this entry. The value of this object will be zero when the map is not applied to an interface.
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmNbmaMapBroadcast 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.7
The broadcast enable/disable setting for this entry. The value true(1) enable broadcast support; disable(2) disabled broadcast support for this entry.
OBJECT-TYPE    
  TruthValue  

juniAtmNbmaMapRowStatus 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.8
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy Additional notes to aid the network manager: - NBMA maps are not supported on dynamic interface. - NBMA maps can only be applied to a single major ATM interface at a time. - NBMA maps cannot be deleted unless the map is removed from the ATM interface (juniAtmNbmaMapIfIndex = 0). - The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and juniAtmNbmaMapIfIndex are zero until the map is applied to a major ATM interface. - To create an entry in this table, the following objects must be present in the set PDU: juniAtmNbmaMapIpAddress juniAtmNbmaMapBroadcast juniAtmNbmaMapRowStatus - Once created, only the following objects can be modified: juniAtmNbmaMapBroadcast
OBJECT-TYPE    
  RowStatus  

juniAtmNbmaMapListTable 1.3.6.1.4.1.4874.2.2.8.1.4.2
This table contains entries for ATM NBMA map lists.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmNbmaMapListEntry

juniAtmNbmaMapListEntry 1.3.6.1.4.1.4874.2.2.8.1.4.2.1
Each entry describes the characteristics of an ATM NBMA map.
OBJECT-TYPE    
  JuniAtmNbmaMapListEntry  

juniAtmNbmaMapListName 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.1
The NBMA Map List name.
OBJECT-TYPE    
  JuniAtmNbmaMapName  

juniAtmNbmaMapListRowStatus 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
OBJECT-TYPE    
  RowStatus  

juniAtmPing 1.3.6.1.4.1.4874.2.2.8.1.5
OBJECT IDENTIFIER    

juniAtmPingTestTypes 1.3.6.1.4.1.4874.2.2.8.1.5.1
OBJECT IDENTIFIER    

juniAtmPingTestOamSeg 1.3.6.1.4.1.4874.2.2.8.1.5.1.1
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using segment OAM cells. The test type must have appended to it a code that uniquely identifies an intermediate point responsible for looping back each cell. If this is absent, the loopbacks are performed at the end of the segment or connection. E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks should be performed at the intermediate point labeled 5.
OBJECT-IDENTITY    

juniAtmPingTestOamE2E 1.3.6.1.4.1.4874.2.2.8.1.5.1.2
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using end-to-end OAM cells.
OBJECT-IDENTITY    

juniAtmVpPingTable 1.3.6.1.4.1.4874.2.2.8.1.5.2
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VpTestTable to do ping (multiple loopback) type testing.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpPingEntry

juniAtmVpPingEntry 1.3.6.1.4.1.4874.2.2.8.1.5.2.1
Each entry describes the characteristics, status and results of the most recent ATM ping test.
OBJECT-TYPE    
  JuniAtmVpPingEntry  

juniAtmVpPingProbeCount 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.1
The number of ping probes (OAM cells) to be sent to complete the test.
OBJECT-TYPE    
  Unsigned32 1..32  

juniAtmVpPingTimeOut 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.2
Specifies the time-out value, in seconds, for a remote ping operation.
OBJECT-TYPE    
  Unsigned32 1..5  

juniAtmVpPingCtlTrapGeneration 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.3
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
OBJECT-TYPE    
  BITS testCompletion(0)  

juniAtmVpPingSentProbes 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.4
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingProbeResponses 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.5
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingStartTime 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.6
The time (sysUpTime) when the test started.
OBJECT-TYPE    
  TimeStamp  

juniAtmVpPingMinRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.7
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingMaxRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.8
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingAverageRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.9
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingTable 1.3.6.1.4.1.4874.2.2.8.1.5.3
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VcTestTable to do ping (multiple loopback) type testing.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcPingEntry

juniAtmVcPingEntry 1.3.6.1.4.1.4874.2.2.8.1.5.3.1
Each entry describes the characteristics, status and results of the most recent ATM ping test.
OBJECT-TYPE    
  JuniAtmVcPingEntry  

juniAtmVcPingProbeCount 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.1
The number of ping probes (OAM cells) to be sent to complete the test.
OBJECT-TYPE    
  Unsigned32 1..32  

juniAtmVcPingTimeOut 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.2
Specifies the time-out value, in seconds, for a remote ping operation.
OBJECT-TYPE    
  Unsigned32 1..5  

juniAtmVcPingCtlTrapGeneration 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.3
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
OBJECT-TYPE    
  BITS testCompletion(0)  

juniAtmVcPingSentProbes 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.4
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingProbeResponses 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.5
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingStartTime 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.6
The time (sysUpTime) when the test started.
OBJECT-TYPE    
  TimeStamp  

juniAtmVcPingMinRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.7
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingMaxRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.8
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingAverageRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.9
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
OBJECT-TYPE    
  Unsigned32  

juniAtmPingTestCode 1.3.6.1.4.1.4874.2.2.8.1.5.4
OBJECT IDENTIFIER    

juniAtmPingTestCodeOamDisabled 1.3.6.1.4.1.4874.2.2.8.1.5.4.1
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the juniAtmIfOamCellRxAdminState is set to disabled.
OBJECT-IDENTITY    

juniAtmPingTestCodeCircuitDown 1.3.6.1.4.1.4874.2.2.8.1.5.4.2
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the operational status of the ATM circuit is down.
OBJECT-IDENTITY    

juniAtmPingTestCodeStopped 1.3.6.1.4.1.4874.2.2.8.1.5.4.3
This test code indicates that the ATM ping operation is administratively stopped by an External Management.
OBJECT-IDENTITY    

juniAtmPingTestCodeOamVcOperState 1.3.6.1.4.1.4874.2.2.8.1.5.4.4
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the circuit is down because of a OAM fault condition. This is possible if juniAtmCircuitVcOamOperStatus is one of the following: oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS. oamVcOperStateRdiState(1) - RDI cell received.
OBJECT-IDENTITY    

juniAtmPingTestCodeMaxPingCountReached 1.3.6.1.4.1.4874.2.2.8.1.5.4.5
This test code indicates that the ping operation cannot be initiated as the maximum number of ping possible on this interfaces exceeds the allowable limit.
OBJECT-IDENTITY    

juniAtmPingTestCodeInvalidParams 1.3.6.1.4.1.4874.2.2.8.1.5.4.6
This Test Code identities the Ping operation cannot be initiated as one or more of the Ping Parameters is Invalid.
OBJECT-IDENTITY    

juniAtmLocation 1.3.6.1.4.1.4874.2.2.8.1.6
OBJECT IDENTIFIER    

juniAtmSubIfLocationType 1.3.6.1.4.1.4874.2.2.8.1.6.1
Describes the interpretation of JuniInterfaceLocationValue object values into platform-dependent interface location components, e.g., 'slot.port' on an ERX.
OBJECT-TYPE    
  JuniInterfaceLocationType  

juniAtmSubIfLocationTable 1.3.6.1.4.1.4874.2.2.8.1.6.2
The entries in this table report the ifIndex of ATM Subinterfaces by location.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfLocationEntry

juniAtmSubIfLocationEntry 1.3.6.1.4.1.4874.2.2.8.1.6.2.1
A specification of ATM subinterfaces by location.
OBJECT-TYPE    
  JuniAtmSubIfLocationEntry  

juniAtmSubIfLocationIndex 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.1
The value of a platform interface location.
OBJECT-TYPE    
  JuniInterfaceLocationValue  

juniAtmSubIfLocationIfIndex 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.2
The ifIndex value of this subinterface.
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVcClass 1.3.6.1.4.1.4874.2.2.8.1.7
OBJECT IDENTIFIER    

juniAtmVcClassNameTable 1.3.6.1.4.1.4874.2.2.8.1.7.1
The entries in this table provide mappings of ATM VC class names to local integer identifiers. These integers are used as indexes into other MIB tables containing ATM VC attributes associated with the same VC class name.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassNameEntry

juniAtmVcClassNameEntry 1.3.6.1.4.1.4874.2.2.8.1.7.1.1
A mapping of ATM VC class name to an integer identifier for the ATM VC class.
OBJECT-TYPE    
  JuniAtmVcClassNameEntry  

juniAtmVcClassName 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.1
The ATM VC class name uniquely identifying this entry.
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

juniAtmVcClassNameRowStatus 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.2
Controls creation/deletion of entries in this table. Only the values 'createAndGo' ,'destroy', 'active' and 'notInService' may be SET. The SNMP manager would set the row status to notInService before making any VC class attribute changes explained in juniAtmVcClassTable. Once the VC class attribute changes are complete, the SNMP manager would set the row status to active, upon which the VC class attribute changes would be committed. Any ATM VC class attribute changes that are made when the row status is 'active' are committed right away.
OBJECT-TYPE    
  RowStatus  

juniAtmVcClassNameId 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.3
The integer identifier associated with this VC class name. The value of this identifier is assigned by the device when an entry in this table is created.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassIdTable 1.3.6.1.4.1.4874.2.2.8.1.7.2
Provides inverse mapping of ATM VC class IDs to ATM VC class names.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassIdEntry

juniAtmVcClassIdEntry 1.3.6.1.4.1.4874.2.2.8.1.7.2.1
A mapping of an integer identifier to an ATM VC class name.
OBJECT-TYPE    
  JuniAtmVcClassIdEntry  

juniAtmVcClassIdId 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.1
The integer identifier associated with this ATM VC class name.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassIdName 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.2
The ATM VC class name having the associated identifier.
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

juniAtmVcClassTable 1.3.6.1.4.1.4874.2.2.8.1.7.3
This table contains Juniper ATM VC Class entries which can be used to specify the ATM PVC attributes either at creation or modification time. A row in this table with default values is created when an entry in juniAtmVcClassNameTable is created.
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassEntry

juniAtmVcClassEntry 1.3.6.1.4.1.4874.2.2.8.1.7.3.1
Each entry contains the attributes of the ATM VC which would be applied to the VC either at creation or modification time when this ATM VC class is associated to it.
OBJECT-TYPE    
  JuniAtmVcClassEntry  

juniAtmVcClassId 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.1
The integer identifier associated with this ATM VC class. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable.
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassVccType 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.2
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VC Mux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)  

juniAtmVcClassVccServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.3
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmVcClassVccPcr 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.4
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVcClassVccScr 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.5
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVcClassVccMbs 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.6
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
OBJECT-TYPE    
  Integer32 0..16777215  

juniAtmVcClassVccOamAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.7
The OAM VC integrity administrative state of the ATM VC associated with this class.
OBJECT-TYPE    
  INTEGER oamAdminStateDisabled(1), oamAdminStateEnabled(2)  

juniAtmVcClassVccOamLoopbackFrequency 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.8
The OAM loopback frequency in seconds.
OBJECT-TYPE    
  Integer32 1..600  

juniAtmVcClassVccOamUpCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.9
Specifies the number of successive loopback cell responses to receive before the ATM VC associated with this class is declared up for connectivity verification.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamDownCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.10
Specifies the number of successive loopback cell responses not received before declaring the ATM VC associated with this class as down for connectivity verification.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamRetryFrequency 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.11
Specifies the frequency (in seconds) to transmit loopback cells when verifying the ATM VC operational state associated with this class (up or down) for connectivity verification.
OBJECT-TYPE    
  Integer32 1..600  

juniAtmVcClassVccOamAlarmDownCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.12
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring the ATM VC associated with class as down.
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamAlarmClearTimeout 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.13
Specifies how long to wait (in seconds) before declaring the ATM VC associated with class as up after it has stopped receiving alarm cells.
OBJECT-TYPE    
  Integer32 3..60  

juniAtmVcClassVccInverseArp 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.14
Enables the inverse ARP protocol on the ATM VC associated with this class; true(1) enables the protocol, false(2) disables it.
OBJECT-TYPE    
  TruthValue  

juniAtmVcClassVccInverseArpRefresh 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.15
The refresh rate in minutes between inverse ARP protocol messages.
OBJECT-TYPE    
  Integer32 0..60  

juniAtmTraps 1.3.6.1.4.1.4874.2.2.8.3
OBJECT IDENTIFIER    

juniAtmTrapPrefix 1.3.6.1.4.1.4874.2.2.8.3.0
OBJECT IDENTIFIER    

juniAtmVpPingTestCompleted 1.3.6.1.4.1.4874.2.2.8.3.0.1
Generated at the completion of a AtmfM4VpTest when the corresponding juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit set.
NOTIFICATION-TYPE    
  atmfM4VpTestId  
  atmfM4VpTestType  
  atmfM4VpTestResult  
  juniAtmVpPingProbeCount  
  juniAtmVpPingSentProbes  
  juniAtmVpPingProbeResponses  
  juniAtmVpPingMinRtt  
  juniAtmVpPingMaxRtt  
  juniAtmVpPingAverageRtt  
  atmfM4VpTestCode  

juniAtmVcPingTestCompleted 1.3.6.1.4.1.4874.2.2.8.3.0.2
Generated at the completion of a AtmfM4VcTest when the corresponding juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit set.
NOTIFICATION-TYPE    
  atmfM4VcTestId  
  atmfM4VcTestType  
  atmfM4VcTestResult  
  juniAtmVcPingProbeCount  
  juniAtmVcPingSentProbes  
  juniAtmVcPingProbeResponses  
  juniAtmVcPingMinRtt  
  juniAtmVcPingMaxRtt  
  juniAtmVcPingAverageRtt  
  atmfM4VcTestCode  

juniAtmConformance 1.3.6.1.4.1.4874.2.2.8.4
OBJECT IDENTIFIER    

juniAtmCompliances 1.3.6.1.4.1.4874.2.2.8.4.1
OBJECT IDENTIFIER    

juniAtmCompliance 1.3.6.1.4.1.4874.2.2.8.4.1.1
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for NBMA map lists and ATM ping.
MODULE-COMPLIANCE    

juniAtmCompliance2 1.3.6.1.4.1.4874.2.2.8.4.1.2
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for traffic shapping on VCC subinterfaces.
MODULE-COMPLIANCE    

juniAtmCompliance3 1.3.6.1.4.1.4874.2.2.8.4.1.3
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for connection admission control (CAC).
MODULE-COMPLIANCE    

juniAtmCompliance4 1.3.6.1.4.1.4874.2.2.8.4.1.4
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when ATM SVC, CAC used bandwidth and sub-interface address objects were added.
MODULE-COMPLIANCE    

juniAtmCompliance5 1.3.6.1.4.1.4874.2.2.8.4.1.5
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when CAC recieve bandwith and E164 public addressing support was added.
MODULE-COMPLIANCE    

juniAtmCompliance6 1.3.6.1.4.1.4874.2.2.8.4.1.6
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when F4 flow OAM circuit config and stats tables were added to the Juniper ATM MIB.
MODULE-COMPLIANCE    

juniAtmCompliance7 1.3.6.1.4.1.4874.2.2.8.4.1.7
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when the juniAtmLocationGroup was added.
MODULE-COMPLIANCE    

juniAtmCompliance8 1.3.6.1.4.1.4874.2.2.8.4.1.8
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added to export the subinterface description to the line cards.
MODULE-COMPLIANCE    

juniAtmCompliance9 1.3.6.1.4.1.4874.2.2.8.4.1.9
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was added.
MODULE-COMPLIANCE    

juniAtmCompliance10 1.3.6.1.4.1.4874.2.2.8.4.1.10
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion, juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were deprecated.
MODULE-COMPLIANCE    

juniAtmCompliance11 1.3.6.1.4.1.4874.2.2.8.4.1.11
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmGroup8 was added.
MODULE-COMPLIANCE    

juniAtmCompliance12 1.3.6.1.4.1.4874.2.2.8.4.1.12
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmVpStatsGroup was added.
MODULE-COMPLIANCE    

juniAtmCompliance13 1.3.6.1.4.1.4874.2.2.8.4.1.13
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when SVC support was removed.
MODULE-COMPLIANCE    

juniAtmCompliance14 1.3.6.1.4.1.4874.2.2.8.4.1.14
The compliance statement for entities which implement the Juniper ATM MIB.
MODULE-COMPLIANCE    

juniAtmGroups 1.3.6.1.4.1.4874.2.2.8.4.2
OBJECT IDENTIFIER    

juniAtmGroup 1.3.6.1.4.1.4874.2.2.8.4.2.1
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when the juniAtmIfMapGroup object was added.
OBJECT-GROUP    

juniAtmAal5Group 1.3.6.1.4.1.4874.2.2.8.4.2.2
A collection of objects providing management of AAL5 interfaces in a Juniper product.
OBJECT-GROUP    

juniAtmSubIfGroup 1.3.6.1.4.1.4874.2.2.8.4.2.3
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfNbma, juniAtmSubIfInverseArp, and juniAtmSubIfInverseArpRefresh were added.
OBJECT-GROUP    

juniAtmVpTunnelGroup 1.3.6.1.4.1.4874.2.2.8.4.2.4
A collection of objects providing management of VP tunnels in a Juniper product.
OBJECT-GROUP    

juniAtmNbmaMapGroup 1.3.6.1.4.1.4874.2.2.8.4.2.5
A collection of object providing management of NBMA in a Juniper product.
OBJECT-GROUP    

juniAtmSubIfGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.6
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfAddress was added.
OBJECT-GROUP    

juniAtmVpPingControlGroup 1.3.6.1.4.1.4874.2.2.8.4.2.7
A collection of object providing management of ATM VPL Ping testing in a Juniper product.
OBJECT-GROUP    

juniAtmVcPingControlGroup 1.3.6.1.4.1.4874.2.2.8.4.2.8
A collection of object providing management of ATM VCL Ping testing in a Juniper product.
OBJECT-GROUP    

juniAtmPingTrapGroup 1.3.6.1.4.1.4874.2.2.8.4.2.9
A collection of notifications supporting ATM Ping testing in a Juniper product.
NOTIFICATION-GROUP    

juniAtmGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.10
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC).
OBJECT-GROUP    

juniAtmTrafficShapingGroup 1.3.6.1.4.1.4874.2.2.8.4.2.11
A collection of objects providing management of ATM traffic shaping in a Juniper product.
OBJECT-GROUP    

juniAtmGroup3 1.3.6.1.4.1.4874.2.2.8.4.2.12
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC) used bandwidth.
OBJECT-GROUP    

juniAtmGroup4 1.3.6.1.4.1.4874.2.2.8.4.2.13
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when CAC recieve bandwith and E164 public addressing objects were added.
OBJECT-GROUP    

juniAtmSvcGroup 1.3.6.1.4.1.4874.2.2.8.4.2.14
Obsolete collection of objects providing management of ATM SVC interfaces in a Juniper product. This group became obsolete when E164 public addressing support was added.
OBJECT-GROUP    

juniAtmSubIfGroup3 1.3.6.1.4.1.4874.2.2.8.4.2.15
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfMtu was added.
OBJECT-GROUP    

juniAtmGroup5 1.3.6.1.4.1.4874.2.2.8.4.2.16
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when ATM VP description support was added.
OBJECT-GROUP    

juniAtmSvcGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.17
A collection of objects providing management of ATM SVC interfaces in a Juniper product.
OBJECT-GROUP    

juniAtmPnniGroup 1.3.6.1.4.1.4874.2.2.8.4.2.18
A collection of objects providing management of PNNI Routing Control Channels in a Juniper product.
OBJECT-GROUP    

juniAtmSubIfGroup4 1.3.6.1.4.1.4874.2.2.8.4.2.19
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when support was added to export the subinterface description to the line cards.
OBJECT-GROUP    

juniAtmF4OamCircuitGroup 1.3.6.1.4.1.4874.2.2.8.4.2.20
Obsolete collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
OBJECT-GROUP    

juniAtmGroup6 1.3.6.1.4.1.4874.2.2.8.4.2.21
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when bulk-configuration profile override support was added.
OBJECT-GROUP    

juniAtmLocationGroup 1.3.6.1.4.1.4874.2.2.8.4.2.22
A collection of objects providing interface location information in a Juniper product.
OBJECT-GROUP    

juniAtmSubIfGroup5 1.3.6.1.4.1.4874.2.2.8.4.2.23
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product.
OBJECT-GROUP    

juniAtmMartiniGroup 1.3.6.1.4.1.4874.2.2.8.4.2.24
A collection of objects providing ATM Martini cell aggregation configuration.
OBJECT-GROUP    

juniAtmGroup7 1.3.6.1.4.1.4874.2.2.8.4.2.25
Obsolete collection of objects providing management of ATM interfaces in a Juniper product.
OBJECT-GROUP    

juniAtmGroup8 1.3.6.1.4.1.4874.2.2.8.4.2.26
A collection of objects providing management of ATM interfaces in a Juniper product.
OBJECT-GROUP    

juniAtmVpStatsGroup 1.3.6.1.4.1.4874.2.2.8.4.2.27
A collection of objects providing ATM VP level statistics.
OBJECT-GROUP    

juniAtmSubIfGroup6 1.3.6.1.4.1.4874.2.2.8.4.2.28
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when ATM SVC support was removed.
OBJECT-GROUP    

juniAtmF4OamCircuitGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.29
A collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
OBJECT-GROUP    

juniAtmGroup9 1.3.6.1.4.1.4874.2.2.8.4.2.30
A collection of objects providing management of ATM interfaces in a Juniper product.
OBJECT-GROUP    

juniAtmSubIfGroup7 1.3.6.1.4.1.4874.2.2.8.4.2.31
A collection of objects providing management of ATM subinterfaces in a Juniper product.
OBJECT-GROUP    

juniAtmVcClassGroup 1.3.6.1.4.1.4874.2.2.8.4.2.32
A collection of objects providing management of ATM VC class in a Juniper product.
OBJECT-GROUP    

Defined Objects

JuniAtmNbmaMapName  
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system.
TEXTUAL-CONVENTION    
  OCTET STRING SIZE(1..32)  

JuniAtmNbmaMapNameOrNull  
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system. Differs from JuniAtmNbmaMapName in that it permits a zero-length string.
TEXTUAL-CONVENTION    
  OCTET STRING SIZE(0..32)  

JuniAtmLocationType  
Obsolete description of the platform-dependent interpretation of a JuniAtmLocationValue object. This textual convention has been relpaced by Juniper-TC.JuniInterfaceLocationType.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), slotPort(1)  

JuniAtmLocationValue  
Obsolete value of a platform-dependent interface location, represented as an OCTET STRING. A corresponding JuniAtmLocationType object identified the mapping of octets to location elements, e.g. 'slot.port'. This textual convention has been replaced by Juniper-TC.JuniInterfaceLocationValue.
TEXTUAL-CONVENTION    
  OCTET STRING SIZE(1..16)  

JuniAtmIfEntry  
SEQUENCE    
  InterfaceIndex as juniAtmIfIndex  
  RowStatus as juniAtmIfRowStatus  
  InterfaceIndexOrZero as juniAtmIfLowerIfIndex  
  AtmVpIdentifier as juniAtmIfIlmiVpi  
  AtmVcIdentifier as juniAtmIfIlmiVci  
  Integer32 as juniAtmIfIlmiVcd  
  Integer32 as juniAtmIfIlmiPollFrequency  
  INTEGER as juniAtmIfIlmiAdminState  
  INTEGER as juniAtmIfUniVersion  
  INTEGER as juniAtmIfOamCellRxAdminState  
  Counter64 as juniAtmIfInCells  
  Counter64 as juniAtmIfOutCells  
  Integer32 as juniAtmIfVcCount  
  JuniAtmNbmaMapNameOrNull as juniAtmIfMapGroup  
  JuniEnable as juniAtmIfCacAdminState  
  Integer32 as juniAtmIfCacUbrWeight  
  Integer32 as juniAtmIfCacSubscriptionBandwidth  
  Integer32 as juniAtmIfCacAvailableBandwidth  
  Integer32 as juniAtmIfCacAvailableBandwidthRx  
  INTEGER as juniAtmIfE164Autoconversion  
  INTEGER as juniAtmIfE164Gateway  
  INTEGER as juniAtmIfE164OneToOneAddrTrans  
  INTEGER as juniAtmIfOamCellFilter  
  Unsigned32 as juniAtmIfCacUsedBandwidthUpper  
  Unsigned32 as juniAtmIfCacUsedBandwidthLower  
  Unsigned32 as juniAtmIfAssociatedVcClassId  

JuniAtmPvcStatisticsEntry  
SEQUENCE    
  InterfaceIndex as juniAtmPvcStatsIfIndex  
  AtmVpIdentifier as juniAtmPvcStatsVpi  
  AtmVcIdentifier as juniAtmPvcStatsVci  
  Counter64 as juniAtmPvcStatsInCells  
  Counter64 as juniAtmPvcStatsInCellOctets  
  Counter64 as juniAtmPvcStatsInPackets  
  Counter64 as juniAtmPvcStatsInPacketOctets  
  Counter64 as juniAtmPvcStatsOutCells  
  Counter64 as juniAtmPvcStatsOutCellOctets  
  Counter64 as juniAtmPvcStatsOutPackets  
  Counter64 as juniAtmPvcStatsOutPacketOctets  
  Counter32 as juniAtmPvcStatsInCellErrors  
  Counter32 as juniAtmPvcStatsinPacketErrors  
  Counter32 as juniAtmPvcStatsOutCellErrors  
  Counter32 as juniAtmPvcStatsOutPacketErrors  
  Counter32 as juniAtmPvcStatsInPacketDiscards  
  Counter32 as juniAtmPvcStatsInPacketOctetDiscards  
  Counter32 as juniAtmPvcStatsInPacketUnknownProtocol  

JuniAtmVpTunnelEntry  
SEQUENCE    
  InterfaceIndex as juniAtmVpTunnelIfIndex  
  AtmVpIdentifier as juniAtmVpTunnelVpi  
  Integer32 as juniAtmVpTunnelKbps  
  RowStatus as juniAtmVpTunnelRowStatus  
  INTEGER as juniAtmVpTunnelServiceCategory  

JuniAtmIfCapabilityEntry  
SEQUENCE    
  InterfaceIndex as juniAtmIfCapabilityIndex  
  TruthValue as juniAtmIfCapabilityTrafficShaping  
  TruthValue as juniAtmIfCapabilityOam  
  Integer32 as juniAtmIfCapabilityDefaultVcPerVp  
  Integer32 as juniAtmIfCapabilityNumVpiVciBits  
  Integer32 as juniAtmIfCapabilityMaxVcd  
  AtmVpIdentifier as juniAtmIfCapabilityMaxVpi  
  AtmVcIdentifier as juniAtmIfCapabilityMaxVci  
  TruthValue as juniAtmIfCapabilityOamCellFilter  

JuniAtmIfSvcSignallingEntry  
SEQUENCE    
  AtmVpIdentifier as juniAtmIfSvcSignallingVpi  
  AtmVcIdentifier as juniAtmIfSvcSignallingVci  
  Integer32 as juniAtmIfSvcSignallingVcd  
  AtmVorXAdminStatus as juniAtmIfSvcSignallingAdminStatus  

JuniAtmIfPnniRccEntry  
SEQUENCE    
  AtmVpIdentifier as juniAtmIfPnniRccVpi  
  AtmVcIdentifier as juniAtmIfPnniRccVci  
  Integer32 as juniAtmIfPnniRccVcd  
  AtmVorXAdminStatus as juniAtmIfPnniRccAdminStatus  

JuniAtmOamF4FlowEndToEndCfgEntry  
SEQUENCE    
  InterfaceIndex as juniAtmOamF4FlowEndToEndIfIndex  
  Integer32 as juniAtmOamF4FlowEndToEndVpi  
  Integer32 as juniAtmOamF4FlowEndToEndLoopbackTimer  
  TruthValue as juniAtmOamF4FlowEndToEndCCSink  
  TruthValue as juniAtmOamF4FlowEndToEndCCSource  
  RowStatus as juniAtmOamF4FlowEndToEndRowStatus  

JuniAtmOamF4FlowSegmentCfgEntry  
SEQUENCE    
  InterfaceIndex as juniAtmOamF4FlowSegmentIfIndex  
  Integer32 as juniAtmOamF4FlowSegmentVpi  
  TruthValue as juniAtmOamF4FlowSegmentCCSink  
  TruthValue as juniAtmOamF4FlowSegmentCCSource  
  RowStatus as juniAtmOamF4FlowSegmentRowStatus  

JuniAtmVpDescrEntry  
SEQUENCE    
  SnmpAdminString as juniAtmVpDescription  

JuniAtmF4FlowOamEndToEndStatsEntry  
SEQUENCE    
  Counter32 as juniAtmF4FlowInOamEndAisCells  
  Counter32 as juniAtmF4FlowInOamEndRdiCells  
  Counter32 as juniAtmF4FlowInOamEndCCCells  
  Counter32 as juniAtmF4FlowInOamEndCCActDeActCells  
  Counter32 as juniAtmF4FlowInOamEndLoopbackCells  
  Counter32 as juniAtmF4FlowOutEndRdiCells  
  Counter32 as juniAtmF4FlowOutEndCCCells  
  Counter32 as juniAtmF4FlowOutEndCCActDeActCells  
  Counter32 as juniAtmF4FlowOutEndToEndLoopbackCells  
  Integer32 as juniAtmF4FlowEndActualLoopbackFreq  
  TimeTicks as juniAtmF4FlowEndLastTimeChanged  
  INTEGER as juniAtmF4FlowOamEndVpOperationState  
  INTEGER as juniAtmF4FlowOamEndVpAdminState  
  Counter32 as juniAtmF4FlowEndInOamCells  
  Counter32 as juniAtmF4FlowEndOutOamCells  
  Counter32 as juniAtmF4FlowEndInOamCellsDropped  
  Counter32 as juniAtmF4FlowEndToEndInLoopbackCmds  
  Counter32 as juniAtmF4FlowEndToEndInLoopbackRsps  
  Counter32 as juniAtmF4FlowEndToEndOutLoopbackCmds  
  Counter32 as juniAtmF4FlowEndToEndOutLoopbackRsps  

JuniAtmF4FlowOamSegmentStatsEntry  
SEQUENCE    
  Counter32 as juniAtmF4FlowInOamSegmentAisCells  
  Counter32 as juniAtmF4FlowInOamSegmentRdiCells  
  Counter32 as juniAtmF4FlowInOamSegmentCCCells  
  Counter32 as juniAtmF4FlowInOamSegmentCCActDeActCells  
  Counter32 as juniAtmF4FlowInOamSegmentLoopbackCells  
  Counter32 as juniAtmF4FlowOutSegmentRdiCells  
  Counter32 as juniAtmF4FlowOutSegmentCCCells  
  Counter32 as juniAtmF4FlowOutSegmentCCActDeActCells  
  Counter32 as juniAtmF4FlowOutSegmentLoopbackCells  
  TimeTicks as juniAtmF4FlowSegmentLastTimeChanged  
  INTEGER as juniAtmF4FlowOamSegmentVpOperationState  
  INTEGER as juniAtmF4FlowOamSegmentVpAdminState  
  Counter32 as juniAtmF4FlowSegmentInOamCells  
  Counter32 as juniAtmF4FlowSegmentOutOamCells  
  Counter32 as juniAtmF4FlowSegmentInOamCellsDropped  
  Counter32 as juniAtmF4FlowSegmentInLoopbackCmds  
  Counter32 as juniAtmF4FlowSegmentInLoopbackRsps  
  Counter32 as juniAtmF4FlowSegmentOutLoopbackCmds  
  Counter32 as juniAtmF4FlowSegmentOutLoopbackRsps  

JuniAtmMartiniTimeoutTimerEntry  
SEQUENCE    
  INTEGER as juniAtmMartiniTimeoutTimerIndex  
  Integer32 as juniAtmMartiniTimeoutTimerValue  

JuniAtmVpStatsEntry  
SEQUENCE    
  InterfaceIndex as juniAtmVpStatsIfIndex  
  AtmVpIdentifier as juniAtmVpStatsVpi  
  Counter64 as juniAtmVpStatsInCells  
  Counter64 as juniAtmVpStatsInPackets  
  Counter64 as juniAtmVpStatsInPacketOctets  
  Counter64 as juniAtmVpStatsOutCells  
  Counter64 as juniAtmVpStatsOutPackets  
  Counter64 as juniAtmVpStatsOutPacketOctets  
  Counter32 as juniAtmVpStatsInPacketErrors  
  Counter32 as juniAtmVpStatsOutPacketErrors  
  Counter32 as juniAtmVpStatsInPacketDiscards  
  Counter32 as juniAtmVpStatsInPacketOctetDiscards  
  Counter32 as juniAtmVpStatsInPacketUnknownProtocol  
  Counter32 as juniAtmVpStatsCrcErrors  
  Counter32 as juniAtmVpStatsSarTimeouts  
  Counter32 as juniAtmVpStatsOverSizedPackets  

JuniAtmAal5IfEntry  
SEQUENCE    
  InterfaceIndex as juniAtmAal5IfIndex  
  RowStatus as juniAtmAal5IfRowStatus  
  InterfaceIndexOrZero as juniAtmAal5IfLowerIfIndex  

JuniAtmBulkCircuitsNameEntry  
SEQUENCE    
  InterfaceIndex as juniAtmBulkCircuitsNameAal5IfIndex  
  DisplayString as juniAtmBulkCircuitsNameName  
  RowStatus as juniAtmBulkCircuitsNameRowStatus  
  Unsigned32 as juniAtmBulkCircuitsNameId  

JuniAtmBulkCircuitsIdEntry  
SEQUENCE    
  InterfaceIndex as juniAtmBulkCircuitsIdAal5IfIndex  
  Unsigned32 as juniAtmBulkCircuitsIdId  
  DisplayString as juniAtmBulkCircuitsIdName  
  Unsigned32 as juniAtmBulkCircuitsIdNextInstance  

JuniAtmBulkCircuitsEntry  
SEQUENCE    
  InterfaceIndex as juniAtmBulkCircuitsAal5IfIndex  
  Unsigned32 as juniAtmBulkCircuitsId  
  Unsigned32 as juniAtmBulkCircuitsInstance  
  RowStatus as juniAtmBulkCircuitsRowStatus  
  AtmVpIdentifier as juniAtmBulkCircuitsMinVpi  
  AtmVpIdentifier as juniAtmBulkCircuitsMaxVpi  
  AtmVcIdentifier as juniAtmBulkCircuitsMinVci  
  AtmVcIdentifier as juniAtmBulkCircuitsMaxVci  
  JuniEnable as juniAtmBulkCircuitsAdminState  

JuniAtmProfileOverrideAssignIfCircuitEntry  
SEQUENCE    
  InterfaceIndex as juniAtmProfileOverrideAssignIfCircuitAal5Index  
  Unsigned32 as juniAtmProfileOverrideAssignIfCircuitRangeId  
  AtmVpIdentifier as juniAtmProfileOverrideAssignIfCircuitVpi  
  AtmVcIdentifier as juniAtmProfileOverrideAssignIfCircuitVci  
  RowStatus as juniAtmProfileOverrideAssignIfCircuitRowStatus  
  Unsigned32 as juniAtmProfileOverrideAssignIfCircuitProfileId  
  INTEGER as juniAtmProfileOverrideAssignIfCircuitOperStatus  

JuniAtmSubIfEntry  
SEQUENCE    
  InterfaceIndex as juniAtmSubIfIndex  
  RowStatus as juniAtmSubIfRowStatus  
  Integer32 as juniAtmSubIfDistinguisher  
  InterfaceIndexOrZero as juniAtmSubIfLowerIfIndex  
  TruthValue as juniAtmSubIfNbma  
  AtmAddr as juniAtmSubIfAddress  
  Integer32 as juniAtmSubIfMtu  
  Integer32 as juniAtmSubIfAdvisoryRxSpeed  
  Integer32 as juniAtmSubIfMartiniMaxCellsPerPacket  
  Integer32 as juniAtmSubIfMartiniTimeoutTimerId  
  Unsigned32 as juniAtmSubIfAssociatedVcClassId  

JuniAtmSubIfVccEntry  
SEQUENCE    
  AtmVpIdentifier as juniAtmSubIfVccVpi  
  AtmVcIdentifier as juniAtmSubIfVccVci  
  RowStatus as juniAtmSubIfVccRowStatus  
  Integer32 as juniAtmSubIfVccVcd  
  INTEGER as juniAtmSubIfVccType  
  INTEGER as juniAtmSubIfVccServiceCategory  
  Integer32 as juniAtmSubIfVccPcr  
  Integer32 as juniAtmSubIfVccScr  
  Integer32 as juniAtmSubIfVccMbs  
  TruthValue as juniAtmSubIfInverseArp  
  Integer32 as juniAtmSubIfInverseArpRefresh  
  Unsigned32 as juniAtmSubIfVccAssociatedVcClassId  

JuniAtmCircuitOamEntry  
SEQUENCE    
  InterfaceIndex as juniAtmCircuitOamIfIndex  
  AtmVpIdentifier as juniAtmCircuitOamVpi  
  AtmVcIdentifier as juniAtmCircuitOamVci  
  INTEGER as juniAtmCircuitOamAdminStatus  
  INTEGER as juniAtmCircuitOamLoopbackOperStatus  
  INTEGER as juniAtmCircuitVcOamOperStatus  
  Integer32 as juniAtmCircuitOamLoopbackFrequency  
  Counter32 as juniAtmCircuitInOamF5Cells  
  Counter32 as juniAtmCircuitInOamCellsDropped  
  Counter32 as juniAtmCircuitOutOamF5Cells  
  Counter32 as juniAtmCircuitInOamF5EndToEndLoopbackCells  
  Counter32 as juniAtmCircuitInOamF5SegmentLoopbackCells  
  Counter32 as juniAtmCircuitInOamF5AisCells  
  Counter32 as juniAtmCircuitInOamF5RdiCells  
  Counter32 as juniAtmCircuitOutOamF5EndToEndLoopbackCells  
  Counter32 as juniAtmCircuitOutOamF5SegmentLoopbackCells  
  Counter32 as juniAtmCircuitOutOamF5RdiCells  
  Counter32 as juniAtmCircuitInOamF5EndToEndLoopbackCmds  
  Counter32 as juniAtmCircuitInOamF5EndToEndLoopbackRsps  
  Counter32 as juniAtmCircuitInOamF5SegmentLoopbackCmds  
  Counter32 as juniAtmCircuitInOamF5SegmentLoopbackRsps  
  Counter32 as juniAtmCircuitOutOamF5EndToEndLoopbackCmds  
  Counter32 as juniAtmCircuitOutOamF5EndToEndLoopbackRsps  
  Counter32 as juniAtmCircuitOutOamF5SegmentLoopbackCmds  
  Counter32 as juniAtmCircuitOutOamF5SegmentLoopbackRsps  
  Integer32 as juniAtmCircuitOamUpCount  
  Integer32 as juniAtmCircuitOamDownCount  
  Integer32 as juniAtmCircuitOamRetryFrequency  
  Integer32 as juniAtmCircuitOamAlarmDownCount  
  Integer32 as juniAtmCircuitOamAlarmClearTimeout  

JuniAtmSubIfVccTrafficShapingEntry  
SEQUENCE    
  Unsigned32 as juniAtmSubIfVccTrafficShapingCdvt  
  TruthValue as juniAtmSubIfVccTrafficShapingClp0  
  TruthValue as juniAtmSubIfVccTrafficShapingTagging  
  TruthValue as juniAtmSubIfVccTrafficShapingPoliceObserve  
  TruthValue as juniAtmSubIfVccTrafficShapingPacketShaping  

JuniAtmSubIfSvcConfigEntry  
SEQUENCE    
  RowStatus as juniAtmSubIfSvcRowStatus  
  AtmAddr as juniAtmSubIfSvcConfigDestAtmAddress  
  INTEGER as juniAtmSubIfSvcConfigCircuitType  
  INTEGER as juniAtmSubIfSvcConfigServiceCategory  
  Unsigned32 as juniAtmSubIfSvcConfigPcr  
  Unsigned32 as juniAtmSubIfSvcConfigScr  
  Unsigned32 as juniAtmSubIfSvcConfigMbs  
  Unsigned32 as juniAtmSubIfSvcConfigCdvt  
  TruthValue as juniAtmSubIfSvcConfigClp0  
  TruthValue as juniAtmSubIfSvcConfigTagging  
  TruthValue as juniAtmSubIfSvcConfigObserve  
  TruthValue as juniAtmSubIfSvcConfigPacketDiscard  
  AtmAddr as juniAtmSubIfSvcConfigDestE164Address  

JuniAtmNbmaMapEntry  
SEQUENCE    
  JuniAtmNbmaMapName as juniAtmNbmaMapName  
  Integer32 as juniAtmNbmaMapVcd  
  IpAddress as juniAtmNbmaMapIpAddress  
  AtmVpIdentifier as juniAtmNbmaMapVpi  
  AtmVcIdentifier as juniAtmNbmaMapVci  
  InterfaceIndexOrZero as juniAtmNbmaMapIfIndex  
  TruthValue as juniAtmNbmaMapBroadcast  
  RowStatus as juniAtmNbmaMapRowStatus  

JuniAtmNbmaMapListEntry  
SEQUENCE    
  JuniAtmNbmaMapName as juniAtmNbmaMapListName  
  RowStatus as juniAtmNbmaMapListRowStatus  

JuniAtmVpPingEntry  
SEQUENCE    
  Unsigned32 as juniAtmVpPingProbeCount  
  Unsigned32 as juniAtmVpPingTimeOut  
  BITS as juniAtmVpPingCtlTrapGeneration  
  Unsigned32 as juniAtmVpPingSentProbes  
  Unsigned32 as juniAtmVpPingProbeResponses  
  TimeStamp as juniAtmVpPingStartTime  
  Unsigned32 as juniAtmVpPingMinRtt  
  Unsigned32 as juniAtmVpPingMaxRtt  
  Unsigned32 as juniAtmVpPingAverageRtt  

JuniAtmVcPingEntry  
SEQUENCE    
  Unsigned32 as juniAtmVcPingProbeCount  
  Unsigned32 as juniAtmVcPingTimeOut  
  BITS as juniAtmVcPingCtlTrapGeneration  
  Unsigned32 as juniAtmVcPingSentProbes  
  Unsigned32 as juniAtmVcPingProbeResponses  
  TimeStamp as juniAtmVcPingStartTime  
  Unsigned32 as juniAtmVcPingMinRtt  
  Unsigned32 as juniAtmVcPingMaxRtt  
  Unsigned32 as juniAtmVcPingAverageRtt  

JuniAtmSubIfLocationEntry  
SEQUENCE    
  JuniInterfaceLocationValue as juniAtmSubIfLocationIndex  
  InterfaceIndex as juniAtmSubIfLocationIfIndex  

JuniAtmVcClassNameEntry  
SEQUENCE    
  DisplayString as juniAtmVcClassName  
  RowStatus as juniAtmVcClassNameRowStatus  
  Unsigned32 as juniAtmVcClassNameId  

JuniAtmVcClassIdEntry  
SEQUENCE    
  Unsigned32 as juniAtmVcClassIdId  
  DisplayString as juniAtmVcClassIdName  

JuniAtmVcClassEntry  
SEQUENCE    
  Unsigned32 as juniAtmVcClassId  
  INTEGER as juniAtmVcClassVccType  
  INTEGER as juniAtmVcClassVccServiceCategory  
  Integer32 as juniAtmVcClassVccPcr  
  Integer32 as juniAtmVcClassVccScr  
  Integer32 as juniAtmVcClassVccMbs  
  INTEGER as juniAtmVcClassVccOamAdminStatus  
  Integer32 as juniAtmVcClassVccOamLoopbackFrequency  
  Integer32 as juniAtmVcClassVccOamUpCount  
  Integer32 as juniAtmVcClassVccOamDownCount  
  Integer32 as juniAtmVcClassVccOamRetryFrequency  
  Integer32 as juniAtmVcClassVccOamAlarmDownCount  
  Integer32 as juniAtmVcClassVccOamAlarmClearTimeout  
  TruthValue as juniAtmVcClassVccInverseArp  
  Integer32 as juniAtmVcClassVccInverseArpRefresh