LIEBERT-MICRO-UPS-MIB
File:
LIEBERT-MICRO-UPS-MIB.mib (11767 bytes)
Imported modules
Imported symbols
Defined Objects
| emerson |
1.3.6.1.4.1.476 |
| OBJECT IDENTIFIER |
|
|
|
| luCore |
1.3.6.1.4.1.476.1.1.1.1 |
| OBJECT IDENTIFIER |
|
|
|
| lcUpsIdent |
1.3.6.1.4.1.476.1.1.1.1.1 |
| OBJECT IDENTIFIER |
|
|
|
| lcUpsIdentSpecific |
1.3.6.1.4.1.476.1.1.1.1.1.4 |
| A reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value. |
| OBJECT-TYPE |
|
|
|
| |
OBJECT IDENTIFIER |
|
|
| lcUpsAlarm |
1.3.6.1.4.1.476.1.1.1.1.6 |
| OBJECT IDENTIFIER |
|
|
|
| lcUpsAlarmId |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.1 |
| A unique identifier for an alarm condition. This value must remain constant between agent initializations. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..2147483647 |
|
| lcUpsAlarmDescr |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.2 |
| A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. |
| OBJECT-TYPE |
|
|
|
| |
OBJECT IDENTIFIER |
|
|
| lcUpsControlUnixShutdownDelay |
1.3.6.1.4.1.476.1.1.1.1.8.5 |
| Setting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..2147483647 |
|
| lcUpsControlUnixShutdownTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.8.6 |
| When 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..2147483647 |
|
| lcUpsControlCancelCommands |
1.3.6.1.4.1.476.1.1.1.1.8.7 |
| Setting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(1), cancel(2) |
|
| lcUpsControlRebootAgentDelay |
1.3.6.1.4.1.476.1.1.1.1.8.8 |
| Setting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. The command can be cancelled by setting lcUpsControlCancleCommand to the value cancel. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..2147483647 |
|
| lcUpsTraps |
1.3.6.1.4.1.476.1.1.1.1.11 |
| OBJECT IDENTIFIER |
|
|
|
| luExternal |
1.3.6.1.4.1.476.1.1.1.6 |
| OBJECT IDENTIFIER |
|
|
|
| luPrivate |
1.3.6.1.4.1.476.1.1.3 |
| OBJECT IDENTIFIER |
|
|
|
Defined Objects
| LcUpsAlarmEntry |
|
| SEQUENCE |
|
|
|
| |
INTEGER as lcUpsAlarmId |
|
|
| |
OBJECT IDENTIFIER as lcUpsAlarmDescr |
|
|
| |
TimeTicks as lcUpsAlarmTime |
|
|