LIVINGSTON-PM4-MIB

File: LIVINGSTON-PM4-MIB.mib (100407 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB LIVINGSTON-ROOT-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks OBJECT-TYPE TRAP-TYPE
DisplayString PhysAddress sysName
lucentPM4

Defined Objects

lucentPM4Mib 1.3.6.1.4.1.307.1.1.2.1
OBJECT IDENTIFIER    

lucentPM4MibRev 1.3.6.1.4.1.307.1.1.2.1.1
This object specifies the current MIB revision number. Example of the MIB revision can be PM4xxx for PM4 product and PM3xxx for PM3 products etc. Where xxx can be any combination of alpha-numeric characters.
OBJECT-TYPE    
  DisplayString SIZE(1..6)  

lucentPM4SWRev 1.3.6.1.4.1.307.1.1.2.1.2
This object specifies the ComOS revision number. Example of the ComOS revision can be ComOS4.xx. Where xxx can be any combination of alpha-numeric characters.
OBJECT-TYPE    
  DisplayString SIZE(1..10)  

lucentPM4Chassis 1.3.6.1.4.1.307.1.1.2.1.3
OBJECT IDENTIFIER    

lucentPM4ChasSummary 1.3.6.1.4.1.307.1.1.2.1.3.1
This object provides general information about the PortMaster 4 chassis operational status. This object is read-only. The DisplayString represents a summary of all the devices in the chassis as follows: Bytes 1 - 2 '0''0' Byte 3 'U', 'D', 'M', 'F', 'O' Byte 4 space Bytes 5 - 6 '0''1' Byte 7 'U', 'D', 'M', 'F', 'O' Byte 8 space Bytes 9 - 10 '0''2' Byte 11 'U', 'D', 'M', 'F', 'O' Byte 12 space Bytes 13 - 14 '0''3' Byte 15 'U', 'D', 'M', 'F', 'O' Byte 16 space Bytes 17 - 18 '0''4' Byte 19 'U', 'D', 'M', 'F', 'O' Byte 20 space Bytes 21 - 22 '0''5' Byte 23 'U', 'D', 'M', 'F', 'O' Byte 24 space Bytes 25 - 26 '0''6' Byte 27 'U', 'D', 'M', 'F', 'O' Byte 28 space Bytes 29 - 30 '0''7' Byte 31 'U', 'D', 'M', 'F', 'O' Byte 32 space Bytes 33 - 34 '0''8' Byte 35 'U', 'D', 'M', 'F', 'O' Byte 36 space Bytes 37 - 38 '0''9' Byte 39 'U', 'D', 'M', 'F', 'O' Byte 40 space Bytes 41 - 42 '1''0' Byte 43 'U', 'D', 'M', 'F', 'O' Byte 44 space Bytes 45 - 46 '1''1' Byte 47 'U', 'D', 'M', 'F', 'O' Byte 48 space Bytes 49 - 50 '1''2' Byte 51 'U', 'D', 'M', 'F', 'O' Byte 52 space Bytes 53 - 54 '1''3' Byte 55 'U', 'D', 'M', 'F', 'O' Byte 56 space Bytes 57 - 58 '1''4' Byte 59 'U', 'D', 'M', 'F', 'O' Byte 60 space Bytes 61 - 62 '1''5' Byte 63 'U', 'D', 'M', 'F', 'O' Byte 64 space Bytes 65 - 66 'P''1' Byte 67 'U', 'D', 'M', 'F', 'O' Byte 68 space Bytes 69 - 70 'P''2' Byte 71 'U', 'D', 'M', 'F', 'O' Byte 72 space Bytes 73 - 74 'P''3' Byte 75 'U', 'D', 'M', 'F', 'O' Byte 76 space Bytes 77 - 78 'D''1' Byte 79 'U', 'D', 'M', 'F', 'O' Byte 80 space Bytes 81 - 82 'D''2' Byte 83 'U', 'D', 'M', 'F', 'O' Byte 84 space Bytes 85 - 86 'F''1' Byte 87 'U', 'D', 'M', 'F', 'O' Byte 88 space Bytes 89 - 90 'F''2' Byte 91 'U', 'D', 'M', 'F', 'O' Byte 92 space Bytes 93 - 94 'F''3' Byte 95 'U', 'D', 'M', 'F', 'O' Byte 96 space Bytes 97 - 98 'F''4' Byte 99 'U', 'D', 'M', 'F', 'O' Legend '#''#' Represents the board number 'F''#' Represents the Fan # 'P''#' Represents the Power Supply # 'D''#' Represents the DC Power Supply # 'U' Up 'D' Down 'M' Maintenance 'F' Failed 'O' Other unknown state.
OBJECT-TYPE    
  DisplayString SIZE(55)  

lucentPM4ChasCmdTable 1.3.6.1.4.1.307.1.1.2.1.3.2
Table describing the commands that can be issued to the agent to perform specific actions to any card, port or device in the system. For example to erase the flash or a particular file from the flash. Note that only a station configured with the appropriate authentication string can issue commands to the agent.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4ChasCmdEntry

lucentPM4ChasCmdEntry 1.3.6.1.4.1.307.1.1.2.1.3.2.1
Entries in the command table for the chassis commands. This describes one entry or row in the command table.
OBJECT-TYPE    
  LucentPM4ChasCmdEntry  

lucentPM4ChasCmdIndex 1.3.6.1.4.1.307.1.1.2.1.3.2.1.1
This object specifies the index in the command table. The values for this object is limited to the size of the command table on the network element. The size of the command table is set to 10 which can be changed if and when users need to schedule more than 10 commands at a given time.
OBJECT-TYPE    
  INTEGER 1..10  

lucentPM4ChasCmdBoardId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2
This object specifies the board for which the command is to be applied. The values for this object is limited to the Max number of boards.
OBJECT-TYPE    
  INTEGER  

lucentPM4ChasCmdUnitType 1.3.6.1.4.1.307.1.1.2.1.3.2.1.3
This object specifies the type of the device to which this command must apply.
OBJECT-TYPE    
  PMUnitType  

lucentPM4ChasCmdUnitIndex 1.3.6.1.4.1.307.1.1.2.1.3.2.1.4
This object specifies the interface index.
OBJECT-TYPE    
  INTEGER  

lucentPM4ChasCmdDevId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.5
This object specifies the sub-unit id for which the command must be applied to. This value will be used by the agent to index to the correct sub-device on a board. For example, this object can have values from 1 - 96 for the modems or 1 - 4 for T1 or 1 - 3 for the E1.
OBJECT-TYPE    
  INTEGER 1..96  

lucentPM4ChasCmdId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.6
This object specifies the command. Each command takes a unique value. The completion status of this command is set in the result object of the table.
OBJECT-TYPE    
  INTEGER eraseflashfile(1), eraseallflash(2), saveall(3), resetport(4), resetfilter(5), adduser(6), deleteuser(7), addlocation(8), diallocation(9), addfilter(10), deletefilter(11), addmodem(12), resetvirtport(13), addospfarea(14), resetospf(15), addprop(16), deleteprop(17), resetprop(18), resetether0(19), resetether1(20), resetall(21), resetconsole(22), version(23), traceroutes(24), ptrace(25), ifconfig(26), eraseconfig(27), erasecomos(28), reboot(29)  

lucentPM4ChasCmdParams 1.3.6.1.4.1.307.1.1.2.1.3.2.1.7
This object specifies the command parameters. Each parameter must be seperated by a blank space. The last parameter is terminated with a ';'.
OBJECT-TYPE    
  OCTET STRING SIZE(0..255)  

lucentPM4ChasCmdResult 1.3.6.1.4.1.307.1.1.2.1.3.2.1.8
This object specifies the command result. The result for each of the previous 10 commands will be stored in a table, which can be retrieved by the client when needed.
OBJECT-TYPE    
  PMDiagCmdStatus  

lucentPM4ConfigMgmt 1.3.6.1.4.1.307.1.1.2.1.4
OBJECT IDENTIFIER    

lucentPM4CmInterfaces 1.3.6.1.4.1.307.1.1.2.1.4.1
OBJECT IDENTIFIER    

lucentPM4CmSerial 1.3.6.1.4.1.307.1.1.2.1.4.1.1
OBJECT IDENTIFIER    

lucentPM4SerialTable 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1
A list of serial interface entries.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4SerialEntry

lucentPM4SerialEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1
A serial interface entry containing objects at the physical and session layer.
OBJECT-TYPE    
  LucentPM4SerialEntry  

lucentPM4SerialBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.1
A unique value for each board in the PortMaster chassis. The Max value of this variable is limited by the number of boards in the chassis. This value is limited to 255.
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialUnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.2
Unit type indicates the serial port. The interface table ifIndex is a combination of board index, unit type and unit index.
OBJECT-TYPE    
  PMUnitType  

lucentPM4SerialIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.3
A unique value for each serial interface on a given board.
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemId 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.4
This object is the cross reference to the modem interface table index. The value is dynamically assigned when the call is established.
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialPortNumber 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.5
A serial port to which this modem is assigned for this call.
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialPhysType 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.6
The type of physical serial interface, distinguished according to the physical/link protocol(s) being currently used on the interface. When this object is set to asyn(2), then the service types dial-in, dial- out, login, and device are valid. When this object is set to sync(3), the serial service types dial-in, dial- out and hardwired are valid.
OBJECT-TYPE    
  INTEGER other(1), async(2), sync(3), isdn(4)  

lucentPM4SerialPortStatus 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.7
The status of the serial interface.
OBJECT-TYPE    
  INTEGER idle(1), connecting(2), established(3), disconnecting(4), command(5), noservice(6)  

lucentPM4SerialDS0State 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.8
Cross reference value for each DS0 for a given T1/E1 line and a given board in the PM4 chassis.
OBJECT-TYPE    
  INTEGER notavailable(1), busyout(2), havecomport(3)  

lucentPM4SerialUser 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.9
Name of the active user. Blank if not active.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

lucentPM4SerialSessionId 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.10
A unique Session Identifier which matches the RADIUS session ID. Blank when not using RADIUS.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

lucentPM4SerialTypeHardwired 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.11
The active type of service being provided by the serial interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeNwDialIn 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.12
The active type of service being provided by the serial interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeNwDialout 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.13
The active type of service being provided by the serial interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeLogin 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.14
The active type of service being provided by the serial interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeDevice 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.15
The active type of service being provided by the serial interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeDeviceName 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.16
Device name if the lucentPM4SerialTypeDevice is enabled. This is a string of characters (e.g. /dev/tty1) indicating the device name.
OBJECT-TYPE    
  DisplayString  

lucentPM4SerialDirection 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.17
The direction the active session was initiated.
OBJECT-TYPE    
  INTEGER in(1), out(2), inout(3)  

lucentPM4SerialStarted 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.18
The amount of time this session has been active.
OBJECT-TYPE    
  TimeTicks  

lucentPM4SerialIdle 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.19
The amount of time this session has been idle.
OBJECT-TYPE    
  TimeTicks  

lucentPM4SerialInSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.20
An estimate of the serial interface's current inbound bandwidth in bits per second.
OBJECT-TYPE    
  Gauge  

lucentPM4SerialOutSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.21
An estimate of the serial interface's current outbound bandwidth in bits per second.
OBJECT-TYPE    
  Gauge  

lucentPM4SerialIpAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.22
The IP address associated with the serial interface. If being used as a network type port, this is the remote user's IP address. If being used as a device or login, this is the IP address of the host the user is connected to.
OBJECT-TYPE    
  IpAddress  

lucentPM4SerialifDescr 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.23
A textual string containing information about the network interface bound to the serial interface.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

lucentPM4SerialInOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.24
The total number of octets received on the serial interface.
OBJECT-TYPE    
  Counter  

lucentPM4SerialOutOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.25
The total number of octets transmitted on the serial interface.
OBJECT-TYPE    
  Counter  

lucentPM4SerialQOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.26
The total number of octets queued on the serial interface.
OBJECT-TYPE    
  Counter  

lucentPM4CmT1E1 1.3.6.1.4.1.307.1.1.2.1.4.1.2
OBJECT IDENTIFIER    

lucentPM4T1E1Table 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1
A list of T1/E1 interface entries.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1Entry

lucentPM4T1E1Entry 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1
A T1/E1 entry containing objects at the physical layer.
OBJECT-TYPE    
  LucentPM4T1E1Entry  

lucentPM4T1E1BoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.1
A unique value for each board in the PM4 chassis.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1UnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.2
This object specifies the type of the unit as the T1/E1 line. This value is a part of the interface table ifIndex.
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1Index 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.3
A unique value for each T1/E1 interface.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1SerialIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.4
The value of the instance for the serial port. This object provides a cross reference from the T1/E1 interface to the serial port to which it is mapped.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1SerialCount 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.5
The number of serial ports assigned to this interface. If this is a Channelized T1/E1, then the count is 24/32. If this is a fractional T1/E1, then the count can be any number between 1 and a number less than 24/32.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PhysType 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.6
The type of interface (T1 or E1).
OBJECT-TYPE    
  INTEGER t1(1), e1(2)  

lucentPM4T1E1Status 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.7
The current operational status of the interface.
OBJECT-TYPE    
  PMEquipPRIStatus  

lucentPM4T1E1Function 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.8
The configured function of the interface.
OBJECT-TYPE    
  INTEGER isdn(1), channelized(2), clear(3), fractional(4), isdnfrac(5)  

lucentPM4T1E1Framing 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.9
The configured line framing.
OBJECT-TYPE    
  INTEGER esf(1), d4(2), crc4(3), fas(4)  

lucentPM4T1E1Encoding 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.10
The configured line signal encoding.
OBJECT-TYPE    
  INTEGER ami(1), b8zs(2), hdb3(3)  

lucentPM4T1E1PCM 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.11
The configured voice modulation.
OBJECT-TYPE    
  INTEGER ulaw(1), alaw(2)  

lucentPM4T1E1SuperSignal 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.12
The configured supervisory signalling mode for this interface.
OBJECT-TYPE    
  INTEGER em(1), groundstart(2)  

lucentPM4T1E1StartMode 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.13
The configured start mode for this interface.
OBJECT-TYPE    
  INTEGER wink(1), immediate(2)  

lucentPM4T1E1ChangeTime 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.14
The amount of time since the last status change.
OBJECT-TYPE    
  TimeTicks  

lucentPM4T1E1RecvLevel 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.15
An estimate of the serial interface's current recieve signal level in DB.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1BlueAlarms 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.16
The total number of Blue Alarms on the interface.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1YellowAlarms 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.17
The total number of Yellow Alarms on the interface.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1CarrierLoss 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.18
The total number of times the interface has lost carrier.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1SyncLoss 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.19
The total number of times the interface has lost frame synchronization.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1BipolarErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.20
The total number of bipolar violations detected on the interface.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1CRCErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.21
The total number of frame level CRC errors detected on the interface.
OBJECT-TYPE    
  Counter  

lucentPM4T1E1SyncErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.22
The total number of frame synchronization errors detected on the interface.
OBJECT-TYPE    
  Counter  

lucentPM4CmModem 1.3.6.1.4.1.307.1.1.2.1.4.1.3
OBJECT IDENTIFIER    

lucentPM4ModemTable 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1
A list of modem entries.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4ModemEntry

lucentPM4ModemEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1
A modem entry containing objects at the session layer.
OBJECT-TYPE    
  LucentPM4ModemEntry  

lucentPM4ModemBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.1
A unique value for each modem interface.
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemUnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.2
Unit type specifies the type of device or interface.
OBJECT-TYPE    
  PMUnitType  

lucentPM4ModemIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.3
A unique value for each modem interface. The value of this object can be 1 - 96 for a Quad T1, 1 - 94 for a Tri E1 card.
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemPortName 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.4
A textual string containing the name of the serial interface (ie. S0, S1, etc).
OBJECT-TYPE    
  DisplayString SIZE(0..8)  

lucentPM4ModemStatus 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.5
A current state of the modem.
OBJECT-TYPE    
  INTEGER none(1), bound(2), connecting(3), active(4), test(5), down(6), ready(7), halt(8), admin(9)  

lucentPM4ModemProtocol 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.6
The error correcting protocol being used in the modem.
OBJECT-TYPE    
  INTEGER none(1), lapm(2), mnp(3), bufferd(4), direct(5), cellular(6)  

lucentPM4ModemCompression 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.7
The compression being used in the modem interface.
OBJECT-TYPE    
  INTEGER none(1), v42bis(2), mnp5(3), stac(4)  

lucentPM4ModemInSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.8
An estimate of the modem interface's current inbound bandwidth in bits per second.
OBJECT-TYPE    
  Gauge  

lucentPM4ModemOutSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.9
An estimate of the modem interface's current outbound bandwidth in bits per second.
OBJECT-TYPE    
  Gauge  

lucentPM4ModemInByteCount 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.10
The total number of bytes received on the serial interface.
OBJECT-TYPE    
  Counter  

lucentPM4ModemOutByteCount 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.11
The total number of bytes transmitted on the serial interface.
OBJECT-TYPE    
  Counter  

lucentPM4ModemRetrains 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.12
The number of retrains attempted by the modem.
OBJECT-TYPE    
  Counter  

lucentPM4ModemRenegotiates 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.13
The number of renegotiates attempted by the modem.
OBJECT-TYPE    
  Counter  

lucentPM4ModemCalls 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.14
The number of times a call received by the modem.
OBJECT-TYPE    
  Counter  

lucentPM4ModemDetects 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.15
The number of analog calls received by the modem.
OBJECT-TYPE    
  Counter  

lucentPM4ModemConnects 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.16
The number of successful calls received by the modem.
OBJECT-TYPE    
  Counter  

lucentPM4CmEther 1.3.6.1.4.1.307.1.1.2.1.4.1.4
OBJECT IDENTIFIER    

lucentPM4EtherTable 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1
A list of ethernet interface entries. This object is not accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4EtherEntry

lucentPM4EtherEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1
Ethernet interface entry containing objects at the Session/Physical layers.
OBJECT-TYPE    
  LucentPM4EtherEntry  

lucentPM4EtherBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.1
A unique value for each ethernet board. The manager card has two ethernet interfaces at present. The ethernet interface in slot 4 has a board ID 10 and if there is a manager card in slot 5, the board ID for the interface would be 11.
OBJECT-TYPE    
  INTEGER  

lucentPM4EtherIfType 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.2
The interface type which together with the board ID and the interface number will uniquely identify the interface.
OBJECT-TYPE    
  PMUnitType  

lucentPM4EtherIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.3
A unique value for each ethernet interface. The manager card has two ethernet interfaces at present. ether0(1) represents 10 Base-T interface and ether1(2) specifies the 10/100 Base-T auto-sensing ethernet interface.
OBJECT-TYPE    
  INTEGER ether0(1), ether1(2), other(3)  

lucentPM4EtherIfIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.4
IfIndex cross reference value for the ethernet interfaces. The manager card has two ethernet interfaces at present. ether0(67436545) represents 10 Base-T interface which corresponds to board 4 and interface 1. The enumerated value ether1(168099841) specifies the 10/100 Base-T auto-sensing ethernet interface which corresponds to board 4 and interface 2. We can add the standby manager card ethernet interfaces when they are available.
OBJECT-TYPE    
  INTEGER ether0(67436545), ether1(168099841)  

lucentPM4EtherPortName 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.5
A printable ASCII string specifying the name of the ethernet port.
OBJECT-TYPE    
  DisplayString SIZE(1..8)  

lucentPM4EtherMacAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.6
Physical address of the interface.
OBJECT-TYPE    
  PhysAddress  

lucentPM4EtherIpAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.7
IP address of the interface.
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherIpGateway 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.8
IP address of the gateway machine.
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherPriNameServer 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.9
IP address of the primary name server.
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherAltNameServer 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.10
IP address of the alternate name server.
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherSubnetMask 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.11
Subnet mask of the interface. Used to partition the network into different branches.
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherInFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.12
IP Input packet filter. Used to control the type of IP packets reaching the interface.
OBJECT-TYPE    
  DisplayString SIZE(1..16)  

lucentPM4EtherOutFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.13
IP output packet filter. Used to control the type of packets sent out of the interface.
OBJECT-TYPE    
  DisplayString SIZE(1..16)  

lucentPM4EtherOptRip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.14
The RIP protocol enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptSlip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.15
The SLIP protocol enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptEtherDown 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.16
Ethernet interface down enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptBcastHigh 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.17
Use high one(s) broadcast address enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptSnmp 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.18
Default SNMP protocol enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoListen 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.19
Do not listen to RIP on the ether interface.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDefaultRip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.20
Default RIP protocol enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDefaultListen 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.21
Default listen enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptIPFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.22
IP filter enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDns 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.23
DNS enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptPmeMsg 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.24
PME Msg. enable/disable option. Whatever that means.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoClip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.25
No Clip enable/disable option. Whatever that means.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptEtherIpx 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.26
Ether IPX enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNetBIOS 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.27
Net BIOS enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptAccounting 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.28
Accounting enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoPAP 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.29
PAP enable/disable option.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4FaultMgmt 1.3.6.1.4.1.307.1.1.2.1.5
OBJECT IDENTIFIER    

lucentPM4FaultMgmtIsolation 1.3.6.1.4.1.307.1.1.2.1.5.1
OBJECT IDENTIFIER    

lucentPM4FaultMgmtChasTrap 1.3.6.1.4.1.307.1.1.2.1.5.1.1
Chassis Trap table which indicates one of several Traps. The chassis trap table stores the previous history of the traps which can be retrieved by the management stations at a later time. This object is not-accessible and present for MIB clarity.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMChasTrapEntry

lucentPM4FMChasTrapEntry 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1
Entry in the chassis Trap table. Each trap is uniquely identified by an index. This object is not accessible and present for MIB clarity.
OBJECT-TYPE    
  LucentPM4FMChasTrapEntry  

lucentPM4FMChasTrapIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.1
Index into the Trap table on the agent. This table stores the previous 500 traps which can be retrieved at any given time.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapBoardID 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.2
Board ID is the board number for which this trap is stored. If the trap is for an auxillary device such as a power supply or fan, this value is set to zero.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapUnitType 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.3
Uniquely specifies the unit type for this trap. The unit can be a board or any other device in the chassis such as a fan or a power supply.
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMChasTrapUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.4
Uniquely specifies the unit index. The unit index is same as the ifIndex for T1/E1 interfaces, or the modemIndex for the modems or fan or power supply index for fan or power supplies.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapStatus 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.5
Trap status specifies the associated object in the Trap is online(2), offline(3), maintenance(4) or fault(5).
OBJECT-TYPE    
  INTEGER other(1), online(2), offline(3), maintenance(4), fault(5), notinstalled(6)  

lucentPM4FMChasTrapSeverity 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.6
Trap severity specifies the severity of the Trap for the associated object.
OBJECT-TYPE    
  PMAlarmType  

lucentPM4FMChasTrapTimeStamp 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.7
This object stores the timestamp of this trap.
OBJECT-TYPE    
  TimeTicks  

lucentPM4FMChasTrapState 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.8
This object stores the Trap state of this trap.
OBJECT-TYPE    
  INTEGER trapsent(1), ackdue(2), acked(3)  

lucentPM4FMBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.2
Board index uniquely specifies the board in the chassis. This object is set to zero for power supplies, fans and other auxillary devices. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.3
Unit index uniquely specifies the T1/E1 line, or modem or any device (logical/physical) in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMUnitType 1.3.6.1.4.1.307.1.1.2.1.5.1.4
Unit type specifies the T1/E1 line, or modem or any device in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMUnitTrapStatus 1.3.6.1.4.1.307.1.1.2.1.5.1.5
Trap status specifies the associated object in the Trap. This object is not accessible other than when produced as the result of a trap.
OBJECT-TYPE    
  INTEGER other(1), offline(2), online(3), failed(4), restored(5), pwrwarn(6), tempwarn(7), temphot(8), dtrloss(9), carrierloss(10), renegotiation(11), los(12), ais(13), redalarm(14), yellowalarm(15), cv(16), crc(17), bpv(18), fer(19), pll(20), es(21), ses(22), sefs(23), uas(24), dm(25), les(26), css(27), bes(28)  

lucentPM4FMUnitTrapSeverity 1.3.6.1.4.1.307.1.1.2.1.5.1.6
Trap severity specifies the severity of the Trap for the associated object. This object is not accessible except when produced as the result of a trap.
OBJECT-TYPE    
  PMAlarmType  

lucentPM4FMTrapConfig 1.3.6.1.4.1.307.1.1.2.1.5.2
OBJECT IDENTIFIER    

lucentPM4FMEqpTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.1
Equipment Trap configuration table configure Traps. The objects in this table are used to enable or disable traps on a per board/interface/device basis. This object is not-accessible and present for MIB clarity.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMEqpTrapCfgEntry

lucentPM4FMEqpTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1
Entry in the equipment Trap config table. Each trap is uniquely identified by the board ID, Unit type and unit index. For auxillary devices such as power supplies and fans, the board index will be zero, the unit index identifies the units and the unit type specifies if the unit is a fan, power supplies etc. This object is not accessible and present for MIB clarity.
OBJECT-TYPE    
  LucentPM4FMEqpTrapCfgEntry  

lucentPM4FMEqpBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.1
Board ID for which the Trap configuration need to apply. The board ID is zero if this trap configuration is for an auxillary device such as fans or power supplies.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEqpUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.2
Unit type alongwith the board index and unit index specifies uniquely the device/interface which is being configured.
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMEqpUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.3
Unit index refers to the interface or sub-device such as a modem, serial port etc. For devices such as power supplies and fans this object is zero.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEqpTrapId 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.4
Trap ID indicating the trap for which the configuration must apply.
OBJECT-TYPE    
  INTEGER boardoffline(1), boardonline(2), pwrsupfail(3), pwrsuprestored(4), fanfail(5), fanrestored(6), boardtempwarn(7), boardtempnormal(8), boardtoohot(9), modemfail(10), linedown(11), lineup(12), linethresh(13), boardpwrshutdown(14), radiusauthfail(15)  

lucentPM4FMEqpTrapCtl 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.5
Trap control which configures the trap off(1) or on(2). When the trap is configured as off(1), the trap is not sent out to the management station. When configures as on(2), the trap is sent to all the management stations configured to receive the trap.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4FMEqpRepTimer 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.6
If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.2
T1/E1 Threshold Trap configuration table to configure the thresholds for various T1/E1 traps. This object is not-accessible and present for MIB clarity.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMThreshT1E1TrapCfgEntry

lucentPM4FMT1E1ThreshTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1
Entry in the T1/E1 threshold trap config table. Each trap is uniquely identified by the board index, unit type and unit index which is the T1/E1 interface number. This object is not accessible and present for MIB clarity.
OBJECT-TYPE    
  LucentPM4FMThreshT1E1TrapCfgEntry  

lucentPM4FMT1E1ThreshBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.1
Board ID for which the Trap threshold configuration must apply. It includes boards 1 - 10 and other devices such as power supplies and fans etc.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.2
Unit type for which the Trap threshold configuration must be applied.
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMT1E1ThreshESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.3
The threshold for errored seconds on the interface. A trap is issued when this set limit is exceeded. When this threshold exceeds, the performance of the interface will degrade. A trap is generated to notify the adminstrator to take appropriate action.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshSESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.4
The threshold for severely errored seconds on the interface. A trap is issued when this limit is exceeded. A severely errored seconds is a second with 320 or more path code violation error events or one or more out of frame defects or detected AIS defect.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshSEFSs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.5
The threshold for severely errored framing seconds. A trap is issued when this threshold is exceeded. A severely errored framing second is a second with one or more frame defects or detected AIS defect.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshUASs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.6
The threshold for unavailable seconds. A trap is issued when this set threshold is exceeded. Unavailable seconds are calculated by counting the number of seconds that the interface is unavailable from the onset of 10 SESs. Once unavailable, the interface becomes available at the onset of 10 contiguous no SESs.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshCSSs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.7
The threshold for controlled slip seconds on the interface. A trap is issued when this set threshold is exceeded. A controlled slip second is a one-second interval containing one or more controlled slips.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshPCVs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.8
The threshold for path code violations on the interface. A trap is issued when this set threshold is exceeded. PCV is a frame syncronization bit error in the D4 and E1-noCRC format interfaces or a CRC error in the ESF (extended super frame) and E1-CRC interface formats.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshLESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.9
The threshold for line errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A line errored second, according to T1M1.3 is a second in which one or more line code violations were detected.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshBESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.10
The threshold for bursty errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A bursty errored second is a second with fewer than 320 and more than 1 path code violations.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshDMs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.11
The threshold for degraded minutes on the interface. A trap is sent to the manager when this set threshold is exceeded. Degraded minutes are determined by collecting all of the available seconds, after removing any severely errored seconds. The resulting seconds is grouped into 60 second intervals and if the cumulative errors during the seconds present in the group exceeds 1E-6.
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshRepTimer 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.12
If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshTrapAck 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.13
If set to ack(3), clears the trap condition. If the value is set to noack(2), leaves the trap condition unchanged.
OBJECT-TYPE    
  INTEGER other(1), noack(2), ack(3)  

lucentPM4FMEnvTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.3
Environment Trap configuration table. This table enables configuration of voltage, power levels and temperature ranges for different units in the chassis. This object is not-accessible and present for MIB clarity.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMEnvTrapCfgEntry

lucentPM4FMEnvTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1
Entry in the environment trap config table. Each trap is uniquely identified by the board index, unit type and unit index. This object is not accessible and present for MIB clarity.
OBJECT-TYPE    
  LucentPM4FMEnvTrapCfgEntry  

lucentPM4FMEnvBoardID 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.1
Board ID specifies the board identifier for this trap. If the trap configuration is for an auxillary device such as a power supply or fan, this object will be set to zero. The unit type and the unit index will uniquely identify the auxillary devices.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.2
Unit for which the Trap configuration must to apply.
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMEnvUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.3
Unit index specifies the interface or sub-unit for this trap (modem or T1/E1 interface etc.). The unit type and the unit index will uniquely identify the auxillary devices.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvOptUnitTemp 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.4
The optimum temperature for this unit. A trap is generated when the temperature deviates from the specified range. The temperature is specified as an integer in degrees farenheit.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitTempRange 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.5
The temperature range above which a trap is generated. The temperature must be specified as an integer in degree Farenhiet (for example +/- 5 degree Far.).
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvOptUnitPwrLvl 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.6
The optimal power level that is appropriate for this unit. A trap is generated when the power level fluctuates outside the limits set.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitPwrRange 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.7
The power range specified in volts. A trap is generated when the power level fluctuates outside the Opt Pwr +/- Range set.
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvTrapCtl 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.8
The trap control used to turn the environment traps on or off for the specified unit(s).
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4PerfMgmt 1.3.6.1.4.1.307.1.1.2.1.6
OBJECT IDENTIFIER    

lucentPM4T1E1PerfMgmt 1.3.6.1.4.1.307.1.1.2.1.6.1
OBJECT IDENTIFIER    

lucentPM4T1E1PMCur 1.3.6.1.4.1.307.1.1.2.1.6.1.1
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMCurEntry

lucentPM4T1E1PMCurEntry 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose.
OBJECT-TYPE    
  LucentPM4T1E1PMCurEntry  

lucentPM4T1E1PMCurBoard 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.1
Board number of the interface. The global interface number is computed by using the Most Significant byte of the ifIndex and the Least Significant 2 bytes represents the interface index. Byte 3 will represent the unit type which would be a T1 or E1.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurUnitType 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.2
Unit type indicates the type of interface as T1/E1 or T3/E3 in future. This is part of the interface table ifIndex which is constructed with boardID, unit type and unit index.
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMCurLineNum 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.3
Line number uniquely identifies the T1/E1 interface on a given board.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.4
Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.5
The number of errored seconds, encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurSESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.6
The number of Severely Errored Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.7
The number of Severely Errored Framing Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurUASs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.8
The number of Unavailable Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurCSSs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.9
The number of Controlled Slip Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurPCVs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.10
The number of Path Coding Violations encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurLESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.11
The number of Line Errored Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurBESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.12
The number of Bursty Errored Seconds encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurDMs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.13
The number of Degraded Minutes encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurLCVs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.14
The number of Line Code Violations encountered by the line in the current 15 mins interval.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMInt 1.3.6.1.4.1.307.1.1.2.1.6.2
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMIntEntry

lucentPM4T1E1PMIntEntry 1.3.6.1.4.1.307.1.1.2.1.6.2.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose.
OBJECT-TYPE    
  LucentPM4T1E1PMIntEntry  

lucentPM4T1E1PMIntBoard 1.3.6.1.4.1.307.1.1.2.1.6.2.1.1
Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntUnitType 1.3.6.1.4.1.307.1.1.2.1.6.2.1.2
Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1.
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMIntLineNum 1.3.6.1.4.1.307.1.1.2.1.6.2.1.3
Line number uniquely identifies the T1/E1 interface for this board.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntInterval 1.3.6.1.4.1.307.1.1.2.1.6.2.1.4
Interval number for a given board. The 24 hr period is divided into 96 15 min intervals, where 1 is the most recent and 96 is the least recent.
OBJECT-TYPE    
  INTEGER 1..96  

lucentPM4T1E1PMIntIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.2.1.5
Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.6
The number of errored seconds, encountered by the line in the last 24 hrs divided into 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntSESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.7
The number of Severely Errored Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.8
The number of Severely Errored Framing Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntUASs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.9
The number of Unavailable Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntCSSs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.10
The number of Controlled Slip Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntPCVs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.11
The number of Path Coding Violations encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntLESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.12
The number of Line Errored Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntBESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.13
The number of Bursty Errored Seconds encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntDMs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.14
The number of Degraded Minutes encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntLCVs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.15
The number of Line Code Violations encountered by the line for one of the 96 15 mins intervals.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotal 1.3.6.1.4.1.307.1.1.2.1.6.3
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMTotalEntry

lucentPM4T1E1PMTotalEntry 1.3.6.1.4.1.307.1.1.2.1.6.3.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose.
OBJECT-TYPE    
  LucentPM4T1E1PMIntEntry  

lucentPM4T1E1PMTotalBoard 1.3.6.1.4.1.307.1.1.2.1.6.3.1.1
Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II. This table stores the cumulative values for the past 24 hr period.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalUnitType 1.3.6.1.4.1.307.1.1.2.1.6.3.1.2
Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1.
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMTotalLineNum 1.3.6.1.4.1.307.1.1.2.1.6.3.1.3
Interface number for a given board. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex in MIB II.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.3.1.4
IfIndex cross reference value. This value is obtained from the Board/board number and interface number by combining them into the LSByte. The upper nibble represents the board and the lower nibble represents the line number.
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.5
The cumulative value of errored seconds, encountered by the line in the last 24 hrs.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalSESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.6
The cumulative value Severely Errored Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.7
The cumulative value of Severely Errored Framing Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalUASs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.8
The cumulative value of Unavailable Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalCSSs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.9
The cumulative value of Controlled Slip Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalPCVs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.10
The cumulative value of Path Coding Violations encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalLESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.11
The cumulative value of Line Errored Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalBESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.12
The cumulative value of Bursty Errored Seconds encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalDMs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.13
The cumulative value of Degraded Minutes encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalLCVs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.14
The cumulative value of Line Code Violations encountered by the line for the 24 hr period.
OBJECT-TYPE    
  Gauge  

lucentPM4SecurityMgmt 1.3.6.1.4.1.307.1.1.2.1.7
OBJECT IDENTIFIER    

lucentPM4AcctMgmt 1.3.6.1.4.1.307.1.1.2.1.8
OBJECT IDENTIFIER    

lucentPM4AcctMgmtComm 1.3.6.1.4.1.307.1.1.2.1.8.1
OBJECT IDENTIFIER    

lucentPM4SnmpCommTable 1.3.6.1.4.1.307.1.1.2.1.8.1.1
The SNMP Community Table. This table contains entries to restrict the SNMP get and set operations.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4SnmpCommEntry

lucentPM4SnmpCommEntry 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1
The entries in the community table.
OBJECT-TYPE    
  LucentPM4SnmpCommEntry  

lucentPM4SnmpCommIndex 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.1
The index of the command in the command table. A MAX of 10 network management stations must be specified along with their community names.
OBJECT-TYPE    
  INTEGER 1..10  

lucentPM4SnmpCommName 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.2
The name of the SNMP Community for SNMP readers and writers. The size of the string is limited to 32 characters. All characters in the string must be printable.
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

lucentPM4SnmpCommIpAddr 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.3
The IP Address of the remote community.
OBJECT-TYPE    
  IpAddress  

lucentPM4SnmpCommReadAccess 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.4
Read access enable or disable for this community. When enabled, it allows read-only variable access using this community string by the SNMP client.
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommWriteAccess 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.5
Write access enable or disable for this community. When enabled, the agent allows write access to the parameters on the agent by the SNMP clients.
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommTraps 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.6
Traps receiving capability enable or disable for this community. When enabled, the SNMP agent forwards the traps generated in the box to this SNMP client.
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommStatus 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.7
The status of the entry for this community. If the status is set to normal, it allows requests from this SNMP client else it discards the requests from this client.
OBJECT-TYPE    
  INTEGER normal(1), delete(2)  

lucentPM4SnmpCommLastError 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.8
If there is an error on a request, this variable may contain a message indicating the error.
OBJECT-TYPE    
  DisplayString SIZE(0..511)  

lucentPM4AcctMgmtCallEvent 1.3.6.1.4.1.307.1.1.2.1.8.2
OBJECT IDENTIFIER    

lucentPM4AMCallEventTable 1.3.6.1.4.1.307.1.1.2.1.8.2.1
Call accounting table containing a list of call events, which may be used for billing purposes.
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4AMCallEventEntry

lucentPM4AMCallEventEntry 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1
The entries in the accounting/billing table.
OBJECT-TYPE    
  LucentPM4AMCallEventEntry  

lucentPM4AMCEIndex 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.1
Call event index used as an index into the call event table. The table stores call events which may be used for billing.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCETimeStamp 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.2
Time stamp for this event in seconds since the last reboot.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEType 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.3
Specifies the type of event associated with this entry in the call event table.
OBJECT-TYPE    
  INTEGER calloriginated(1), callanswered(2), callcleared(3), servicechanged(4), namechanged(5), baudratechanged(6)  

lucentPM4AMCESvcType 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.4
The type of service provided to the user. This field is meaningful if the event type is servicechanged(4), or namechanged(5) events. In all other cases, this object must return none(1).
OBJECT-TYPE    
  INTEGER none(1), ppp(2), slip(3), mpp(4), x25(5), combinet(6), frameRelay(7), euraw(8), euui(9), telnet(10), telnetBinary(11), rawTcp(12), terminalServer(13), mp(14), virtualConnect(15), x25DChannel(16)  

lucentPM4AMCEUName 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.5
User name of the dialed in user. This object returns the valid user name when the event type is servicechanged(4) or namechanged(5). In all other cases, it returns a NULL.
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEModemBoard 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.6
Board ID of the modem which handled this call. This value can be used to diagnose modem related problems (dropping the call, retraining too frequently etc.).
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEModemID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.7
Identifies the specific modem on a board which handled this call. Can be used to diagnose modem related problems.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEModemPort 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.8
A textual string containing the name of the serial interface (ie. S0, S1, etc).
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEDataRate 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.9
Specifies the speed of this connection. Speed is specified as baud rate for modem calls and receive data rate for ISDN calls. This object returns a 0 for call answered and call cleared events.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCECallingPartyID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.10
Calling party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL.
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCECalledPartyID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.11
Called party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL.
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEInOctets 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.12
Total octets received during this call. This object is cleared at the end of each call.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEOutOctets 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.13
Total octets sent out during this call. This object is cleared at the end of each call.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCECallCharge 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.14
Call charge for this call. This object is valid only when the event is call cleared. For all other events this object is set to zero.
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEDisconnReason 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.15
Reason for the disconnect.
OBJECT-TYPE    
  INTEGER notApplicable(1), unknown(2), disconnected(3), clidAuthFailed(4), clidAuthServTimeout(5), clidAuthRequestCallback(6), preT310Timeout(7), noModemAvailable(9), noModemNoCarrier(10), noModemLossCarrier(11), noModemResultCodes(12), noModemOpenFailed(13), noModemOpenFailedDiag(14), tsUserExit(20), tsIdleTimeout(21), tsExitTelnet(22), tsNoIPAddr(23), tsExitTcp(24), tsPassWordFail(25), tsRawTCPDisable(26), tsControlC(27), tsDestroyed(28), tsClosedVirtualConnect(29), tsVirtualConnectDestroyed(30), tsExitRlogin(31), tsRloginBadOption(32), tsErrorResource(33), mpNullMessageTimeout(35), pppLcpTimeout(40), pppLcpNegotiateFail(41), pppPAPAuthFail(42), pppCHAPAuthFail(43), pppRemoteAuthFail(44), pppRcvTerminate(45), pppCloseEvent(46), pppCloseNoNcpsOpened(47), pppCloseUnknownMpBundle(48), pppCloseMpAddChanFail(49), tsExitErrTooMany(50), tsExitErrResource(51), tsExitErrInvalidIP(52), tsExitErrHostName(53), tsExitErrBadPort(54), tsExitErrHostReset(60), tsExitErrConnRefused(61), tsExitErrTimedOut(62), tsExitErrClosed(63), tsExitErrNetUnreach(64), tsExitErrHostUnreach(65), tsExitErrNetAdminUnreach(66), tsExitErrHostAdminUnreach(67), tsExitErrPortUnreach(68), sessTimeOut(100), sessFailSecurity(101), sessCallback(102), invalidProtocol(120), requestByRadiusClient(150), localAdmin(151), localSnmp(152), v110Timeout(160), pppAuthTimeout(170), userCallClearRequest(180), remoteEndHungUp(185), resourceQuiesced(190), maxCallDurationReached(195), lowMemory(201), boardDied(210)  

lucentPM4Traps 1.3.6.1.4.1.307.1.1.2.2
OBJECT IDENTIFIER    

lucentPM4BoardOfflineTrap 1.3.6.1.4.1.307.1.1.2.2.1
Board down trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4BoardOnlineTrap 1.3.6.1.4.1.307.1.1.2.2.2
Board up trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4PwrSupFailTrap 1.3.6.1.4.1.307.1.1.2.2.3
Power supply failed trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4PwrSupWarnTrap 1.3.6.1.4.1.307.1.1.2.2.4
Power supply warning trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when the power supply fluctuates between a set threshold. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4PwrSupRestoredTrap 1.3.6.1.4.1.307.1.1.2.2.5
Power supply restored trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when a failed power supply is restored. This must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4FanFailTrap 1.3.6.1.4.1.307.1.1.2.2.6
Fan failure trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4FanRestoredTrap 1.3.6.1.4.1.307.1.1.2.2.7
Fan restored trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap is issued when the failed fan is restored. This trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4BoardTempWarnTrap 1.3.6.1.4.1.307.1.1.2.2.8
Board temperature warning trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature exceeds a set threshold value. This trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4BoardTempNormalTrap 1.3.6.1.4.1.307.1.1.2.2.9
Board temperature normal trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature returns to normal. This trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4BoardTooHotTrap 1.3.6.1.4.1.307.1.1.2.2.10
Board trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4ModemFailTrap 1.3.6.1.4.1.307.1.1.2.2.11
Modem failure trap. The variable bindings in the Trap packet provide information about the chassis name, modem number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4T1E1LineDownTrap 1.3.6.1.4.1.307.1.1.2.2.12
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4T1E1LineUpTrap 1.3.6.1.4.1.307.1.1.2.2.13
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4T1E1LineThreshTrap 1.3.6.1.4.1.307.1.1.2.2.14
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the trap type. This Trap could be generated when the thresholds for the various performance statistics (ES, SES etc.) exceed. It must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitIndex  
  lucentPM4FMUnitTrapStatus  

lucentPM4BoardPwrOffTrap 1.3.6.1.4.1.307.1.1.2.2.15
This trap is issued when the power supply to the board is not enough. The variable bindings in the Trap packet provide information about the chassis name, board/board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitType  
  lucentPM4FMUnitTrapStatus  

lucentPM4RadiusAuthFailTrap 1.3.6.1.4.1.307.1.1.2.2.16
This trap is issued when the Radius authentication fails. This Trap must be cleared manually. The trap provides information about the board and the modem number.
TRAP-TYPE    
  sysName  
  lucentPM4FMBoardIndex  
  lucentPM4FMUnitIndex  

Defined Objects

PMUnitType  
INTEGER mrgmodule(1), quadt1(2), trie1(3), modem(4), serialport(5), ether0(6), ether1(7), console(8), acpwrsup(9), fan(10), dcpwrsup(11), allunits(255)    

PMEquipPRIStatus  
INTEGER up(1), down(2), loopback(3), fault(4)    

PMEquipStatus  
INTEGER up(1), down(2), maintenance(3), fault(4), other(5)    

PMDiagCmdStatus  
INTEGER success(1), fail(2), inprogress(3), notsupported(4), aborted(5), other(6)    

PMDiagTestCntrl  
INTEGER normal(1), start(2), stop(3), abort(4)    

PMAlarmType  
INTEGER informational(1), warning(2), minor(3), major(4), critical(5)    

LucentPM4ChasCmdEntry  
SEQUENCE    
  INTEGER as lucentPM4ChasCmdIndex  
  INTEGER as lucentPM4ChasCmdBoardId  
  PMUnitType as lucentPM4ChasCmdUnitType  
  INTEGER as lucentPM4ChasCmdUnitIndex  
  INTEGER as lucentPM4ChasCmdDevId  
  INTEGER as lucentPM4ChasCmdId  
  OCTET STRING as lucentPM4ChasCmdParams  
  INTEGER as lucentPM4ChasCmdResult  

LucentPM4SerialEntry  
SEQUENCE    
  INTEGER as lucentPM4SerialBoardIndex  
  PMUnitType as lucentPM4SerialUnitType  
  INTEGER as lucentPM4SerialIndex  
  INTEGER as lucentPM4ModemId  
  INTEGER as lucentPM4SerialPortNumber  
  INTEGER as lucentPM4SerialPhysType  
  INTEGER as lucentPM4SerialPortStatus  
  INTEGER as lucentPM4SerialDS0State  
  DisplayString as lucentPM4SerialUser  
  DisplayString as lucentPM4SerialSessionId  
  INTEGER as lucentPM4SerialTypeHardwired  
  INTEGER as lucentPM4SerialTypeNwDialIn  
  INTEGER as lucentPM4SerialTypeNwDialout  
  INTEGER as lucentPM4SerialTypeLogin  
  INTEGER as lucentPM4SerialTypeDevice  
  DisplayString as lucentPM4SerialTypeDeviceName  
  INTEGER as lucentPM4SerialDirection  
  TimeTicks as lucentPm4SerialStarted  
  TimeTicks as lucentPM4SerialIdle  
  Gauge as lucentPM4SerialInSpeed  
  Gauge as lucentPM4SerialOutSpeed  
  IpAddress as lucentPM4SerialIpAddress  
  DisplayString as lucentPM4SerialifDescr  
  Counter as lucentPM4SerialInOctets  
  Counter as lucentPM4SerialOutOctets  
  Counter as lucentPm4SerialQOctets  

LucentPM4T1E1Entry  
SEQUENCE    
  INTEGER as lucentPM4T1E1BoardIndex  
  PMUnitType as lucentPM4T1E1UnitType  
  INTEGER as lucentPM4T1E1Index  
  INTEGER as lucentPM4T1E1SerialIndex  
  INTEGER as lucentPM4T1E1SerialCount  
  INTEGER as lucentPM4T1E1PhysType  
  INTEGER as lucentPM4T1E1Status  
  INTEGER as lucentPM4T1E1Function  
  INTEGER as lucentPM4T1E1Framing  
  INTEGER as lucentPM4T1E1Encoding  
  INTEGER as lucentPM4T1E1PCM  
  INTEGER as lucentPM4T1E1SuperSignal  
  INTEGER as lucentPM4T1E1StartMode  
  TimeTicks as lucentPM4T1E1ChangeTime  
  Gauge as lucentPM4T1E1RecvLevel  
  Counter as lucentPM4T1E1BlueAlarms  
  Counter as lucentPM4T1E1YellowAlarms  
  Counter as lucentPM4T1E1CarrierLoss  
  Counter as lucentPM4T1E1SyncLoss  
  Counter as lucentPM4T1E1BipolarErrors  
  Counter as lucentPM4T1E1CRCErrors  
  Counter as lucentPM4T1E1SyncErrors  

LucentPM4ModemEntry  
SEQUENCE    
  INTEGER as lucentPM4ModemBoardIndex  
  PMUnitType as lucentPM4ModemUnitType  
  INTEGER as lucentPM4ModemIndex  
  DisplayString as lucentPM4ModemPortName  
  INTEGER as lucentPM4ModemStatus  
  INTEGER as lucentPM4ModemProtocol  
  INTEGER as lucentPM4ModemCompression  
  Gauge as lucentPM4ModemInSpeed  
  Gauge as lucentPM4ModemOutSpeed  
  Counter as lucentPM4ModemInByteCount  
  Counter as lucentPM4ModemOutByteCount  
  Counter as lucentPM4ModemRetrains  
  Counter as lucentPM4ModemRenegotiates  
  Counter as lucentPM4ModemCalls  
  Counter as lucentPM4ModemDetects  
  Counter as lucentPM4ModemConnects  

LucentPM4EtherEntry  
SEQUENCE    
  INTEGER as lucentPM4EtherBoardIndex  
  PMUnitType as lucentPM4EtherIfType  
  INTEGER as lucentPM4EtherIndex  
  INTEGER as lucentPM4EtherIfIndex  
  DisplayString as lucentPM4EtherPortName  
  PhysAddress as lucentPM4EtherMacAddr  
  IpAddress as lucentPM4EtherIPAddr  
  IpAddress as lucentPM4EtherIPGateway  
  IpAddress as lucentPM4EtherPriNameServer  
  IpAddress as lucentPM4EtherAltNameServer  
  IpAddress as lucentPM4EtherSubnetMask  
  DisplayString as lucentPM4EtherInFilter  
  DisplayString as lucentPM4EtherOutFilter  
  INTEGER as lucentPM4EtherOptRip  
  INTEGER as lucentPM4EtherOptSlip  
  INTEGER as lucentPM4EtherOptEtherDown  
  INTEGER as lucentPM4EtherOptBcastHigh  
  INTEGER as lucentPM4EtherOptSnmp  
  INTEGER as lucentPM4EtherOptNoListen  
  INTEGER as lucentPM4EtherOptDefaultRip  
  INTEGER as lucentPM4EtherOptDefaultListen  
  INTEGER as lucentPM4EtherOptIPFilter  
  INTEGER as lucentPM4EtherOptDns  
  INTEGER as lucentPM4EtherOptPmeMsg  
  INTEGER as lucentPM4EtherOptNoClip  
  INTEGER as lucentPM4EtherOptEtherIpx  
  INTEGER as lucentPM4EtherOptNetBIOS  
  INTEGER as lucentPM4EtherOptAccounting  
  INTEGER as lucentPM4EtherOptNoPAP  

LucentPM4FMChasTrapEntry  
SEQUENCE    
  INTEGER as lucentPM4FMChasTrapIndex  
  INTEGER as lucentPM4FMChasBoardID  
  PMUnitType as lucentPM4FMChasTrapUnitType  
  INTEGER as lucentPM4FMChasTrapUnitIndex  
  INTEGER as lucentPM4FMChasTrapStatus  
  INTEGER as lucentPM4FMChasTrapSeverity  
  TimeTicks as lucentPM4FMChasTrapTimeStamp  
  INTEGER as lucentPM4FMChasTrapState  

LucentPM4FMEqpTrapCfgEntry  
SEQUENCE    
  INTEGER as lucentPM4FMEqpBoardIndex  
  PMUnitType as lucentPM4FMEqpUnitType  
  INTEGER as lucentPM4FMEqpunitIndex  
  INTEGER as lucentPM4FMEqpTrapId  
  INTEGER as lucentPM4FMEqpTrapCtl  
  INTEGER as lucentPM4FMEqpTrapRepTimer  

LucentPM4FMThreshT1E1TrapCfgEntry  
SEQUENCE    
  INTEGER as lucentPM4FMT1E1ThreshBoardIndex  
  INTEGER as lucentPM4FMT1E1ThreshUnitType  
  INTEGER as lucentPM4FMT1E1ThreshUnitIndex  
  Gauge as lucentPM4FMT1E1ThreshESs  
  Gauge as lucentPM4FMT1E1ThreshSESs  
  Gauge as lucentPM4FMT1E1ThreshSEFSs  
  Gauge as lucentPM4FMT1E1ThreshUASs  
  Gauge as lucentPM4FMT1E1ThreshCSSs  
  Gauge as lucentPM4FMT1E1ThreshPCVs  
  Gauge as lucentPM4FMT1E1ThreshLESs  
  Gauge as lucentPM4FMT1E1ThreshBESs  
  Gauge as lucentPM4FMT1E1ThreshDMs  
  INTEGER as lucentPM4FMT1E1ThreshTrapRepTimer  
  INTEGER as lucentPM4FMT1E1ThreshTrapAck  

LucentPM4FMEnvTrapCfgEntry  
SEQUENCE    
  INTEGER as lucentPM4FMEnvBoardID  
  PMUnitType as lucentPM4FMEnvUnitType  
  INTEGER as lucentPM4FMEnvUnitIndex  
  INTEGER as lucentPM4FMEnvOptUnitTemp  
  INTEGER as lucentPM4FMEnvUnitTempRange  
  INTEGER as lucentPM4FMEnvOptUnitPwrLvl  
  INTEGER as lucentPM4FMEnvUnitPwrRange  
  INTEGER as lucentPM4FMEnvTrapCtl  
  INTEGER as lucentPM4FMEnvTrapRepTimer  

LucentPM4T1E1PMCurEntry  
SEQUENCE    
  INTEGER as lucentPM4T1E1PMCurBoardID  
  PMUnitType as lucentPM4T1E1PMCurUnitType  
  INTEGER as lucentPM4T1E1PMCurLineNum  
  INTEGER as lucentPM4T1E1PMCurIfIndex  
  Gauge as lucentPM4T1E1PMCurESs  
  Gauge as lucentPM4T1E1PMCurSESs  
  Gauge as lucentPM4T1E1PMCurSEFs  
  Gauge as lucentPM4T1E1PMCurUASs  
  Gauge as lucentPM4T1E1PMCurCSSs  
  Gauge as lucentPM4T1E1PMCurPCVs  
  Gauge as lucentPM4T1E1PMCurLESs  
  Gauge as lucentPM4T1E1PMCurBESs  
  Gauge as lucentPM4T1E1PMCurDMs  
  Gauge as lucentPM4T1E1PMCurLCVs  

LucentPM4T1E1PMIntEntry  
SEQUENCE    
  INTEGER as lucentPM4T1E1PMIntBoard  
  PMUnitType as lucentPM4T1E1PMIntUnitType  
  INTEGER as lucentPM4T1E1PMIntLineNum  
  INTEGER as lucentPM4T1E1PMIntIfIndex  
  INTEGER as lucentPM4T1E1PMIntInterval  
  Gauge as lucentPM4T1E1PMIntESs  
  Gauge as lucentPM4T1E1PMIntSESs  
  Gauge as lucentPM4T1E1PMIntSEFs  
  Gauge as lucentPM4T1E1PMIntUASs  
  Gauge as lucentPM4T1E1PMIntCSSs  
  Gauge as lucentPM4T1E1PMIntPCVs  
  Gauge as lucentPM4T1E1PMIntLESs  
  Gauge as lucentPM4T1E1PMIntBESs  
  Gauge as lucentPM4T1E1PMIntDMs  
  Gauge as lucentPM4T1E1PMIntLCVs  

LucentPM4T1E1PMTotalEntry  
SEQUENCE    
  INTEGER as lucentPM4T1E1PMTotalBoard  
  PMUnitType as lucentPM4T1E1PMTotalUnitType  
  INTEGER as lucentPM4T1E1PMTotalLineNum  
  INTEGER as lucentPM4T1E1PMTotalIfIndex  
  Gauge as lucentPM4T1E1PMTotalESs  
  Gauge as lucentPM4T1E1PMTotalSESs  
  Gauge as lucentPM4T1E1PMTotalSEFs  
  Gauge as lucentPM4T1E1PMTotalUASs  
  Gauge as lucentPM4T1E1PMTotalCSSs  
  Gauge as lucentPM4T1E1PMTotalPCVs  
  Gauge as lucentPM4T1E1PMTotalLESs  
  Gauge as lucentPM4T1E1PMTotalBESs  
  Gauge as lucentPM4T1E1PMTotalDMs  
  Gauge as lucentPM4T1E1PMTotalLCVs  

LucentPM4SnmpCommEntry  
SEQUENCE    
  INTEGER as lucentPM4SnmpCommIndex  
  DisplayString as lucentPM4SnmpCommName  
  IpAddress as lucentPM4SnmpCommIpAddr  
  INTEGER as lucentPM4SnmpCommReadAccess  
  INTEGER as lucentPM4SnmpCommWriteAccess  
  INTEGER as lucentPM4SnmpCommTraps  
  INTEGER as lucentPM4SnmpCommStatus  
  DisplayString as lucentPM4SnmpCommLastError  

LucentPM4AMCallEventEntry  
SEQUENCE    
  INTEGER as lucentPM4AMCEIndex  
  INTEGER as lucentPM4AMCETimeStamp  
  INTEGER as lucentPM4AMCEType  
  INTEGER as lucentPM4AMCESvcType  
  DisplayString as lucentPM4AMCEUName  
  INTEGER as lucentPM4AMCEModemBoard  
  INTEGER as lucentPM4AMCEModemID  
  DisplayString as lucentPM4AMCEModemPort  
  INTEGER as lucentPM4AMCEDataRate  
  DisplayString as lucentPM4AMCECallingPartyID  
  DisplayString as lucentPM4AMCECalledPartyID  
  INTEGER as lucentPM4AMCEInOctets  
  INTEGER as lucentPM4AMCEOutOctets  
  INTEGER as lucentPM4AMCECallCharge  
  INTEGER as lucentPM4AMCEDisconnReason