MC2350-MIB

File: MC2350-MIB.mib (233775 bytes)

Imported modules

SNMPv2-TC RFC1155-SMI RFC-1212
SNMPv2-SMI RFC1213-MIB HOST-RESOURCES-MIB

Imported symbols

TEXTUAL-CONVENTION TimeTicks enterprises
NetworkAddress IpAddress Counter
DateAndTime OBJECT-TYPE Counter32
Integer32 DisplayString PhysAddress
hrDeviceIndex

Defined Objects

minolta 1.3.6.1.4.1.2590
OBJECT IDENTIFIER    

mltMgmt 1.3.6.1.4.1.2590.1
OBJECT IDENTIFIER    

mltMib 1.3.6.1.4.1.2590.1.1
OBJECT IDENTIFIER    

mltSystem 1.3.6.1.4.1.2590.1.1.1
OBJECT IDENTIFIER    

mltPrinter 1.3.6.1.4.1.2590.1.1.1.1
OBJECT IDENTIFIER    

mltPrinterMib 1.3.6.1.4.1.2590.1.1.1.1.6
OBJECT IDENTIFIER    

mltPrtMibInfo 1.3.6.1.4.1.2590.1.1.1.1.6.1
OBJECT IDENTIFIER    

mltPrtMibVersion 1.3.6.1.4.1.2590.1.1.1.1.6.1.1
The standardization version of MIB implemented in a printer. This indicates the version of the Private Printer MIB that is implemented. There are some mib objects that indicate the Mib Version. (mltSysMibVersion, mltPrtMibVersion, mltScnMibVersion, mltNetMibVersion, mltJmMibVersion) But, the each mib version should be same version. Especially, the each major versions must be same. A string specifying Printer MIB Standard specification version. General form is ##.XX. ## is indicating major revision, and XX is minor revision. Decimal point is ASCII-coded period.
OBJECT-TYPE    
  DisplayString SIZE(0..7)  

mltPrtCommand 1.3.6.1.4.1.2590.1.1.1.1.6.4
OBJECT IDENTIFIER    

mltPrtCommandTable 1.3.6.1.4.1.2590.1.1.1.1.6.4.1
The table for showing the command information of printer relation. This table must be implemented even if no function in this table are supported by a model.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtCommandEntry

mltPrtCommandEntry 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'.
OBJECT-TYPE    
  MltPrtCommandEntry  

mltPrtCommandOnline 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.1
Indicate printer online or offline. If printer has no online button, this value should be notSupported (0) as read-only.
OBJECT-TYPE    
  INTEGER notSupported(0), onLine(1), offLine(2)  

mltPrtCommandJobCancel 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.2
Command of cancel job. If printer has not job cancel function, this value should be notSupported (0) as read-only. In normal condition, this value should be notCancel (1). If canceling job, set this object jobCancel (2).
OBJECT-TYPE    
  INTEGER notSupported(0), notCancel(1), jobCancel(2)  

mltPrtCommandJobProceed 1.3.6.1.4.1.2590.1.1.1.1.6.4.1.1.3
Command of proceeds. If printer has not proceed function, this value should be notSupported (0) as read-only. In normal condition, this value should be notProceed (1). If proceeding job, set this object proceed (2).
OBJECT-TYPE    
  INTEGER notSupported(0), notProceed(1), jobProceed(2)  

mltPrtPrintPageTable 1.3.6.1.4.1.2590.1.1.1.1.6.4.2
A table of printable configuration print. If a printer does not support print the test pages from network access, this table needs not to be implemented.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPrintPageEntry

mltPrtPrintPageEntry 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1
Information about printer's configuration prints. Entries may exist in the table for each device index whose device type is 'printer'.
OBJECT-TYPE    
  MltPrtPrintPageEntry  

mltPrtPrintPageIndex 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.1
Index for uniquely distinguishing the page held within a printer. Although the value of index depends on an implementation,
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPrintPageName 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.2
The name of the page, which can be printed. The value that should be implemented depends on an implementation of a model and it should be common with a manual etc.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltPrtPrintCommand 1.3.6.1.4.1.2590.1.1.1.1.6.4.2.1.3
Command of print page. In normal condition , this value should be supported (1). If print page, set this object print (2).
OBJECT-TYPE    
  INTEGER supported(1), print(2)  

mltPrtConfig 1.3.6.1.4.1.2590.1.1.1.1.6.5
OBJECT IDENTIFIER    

mltPrtSysConfigTable 1.3.6.1.4.1.2590.1.1.1.1.6.5.1
A table of configurations for printer. This table must be implemented even if no functions in this table are supported.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtSysConfigEntry

mltPrtSysConfigEntry 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'.
OBJECT-TYPE    
  MltPrtSysConfigEntry  

mltPrtJobLanguage 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.1
Configuration printer job language. Only in the case that a printer has a function of setting(changing) this default printer language, this object is implemented as RW. In the other case, this object should be implemented as RO. In case of PCL/PS printer, default value is Auto(0). If necessary, PCL(1)/PS(2) is changeable. In case of printer has only one interpreter (PCL or PS), this object should be pcl(1) or ps (2) as RO. In case of GDI printer, this value is GDI(3) (RO).
OBJECT-TYPE    
  INTEGER auto(0), pcl(1), ps(2), gdi(3), linePrinter(4), other(7)  

mltPrtPowerSave 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.2
Timer value setting before the power save mode is asserted. Unit is minutes. If '0' is selected, the controller doesn't enter Power Save mode. If this value is -1, printer doesn't support power save mode. If out of spec value is set, Error is returned.
OBJECT-TYPE    
  INTEGER  

mltPrtAutoContinue 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.3
The setting whether printing will automatically recover or not when an Error or Caution occurred. If a device support only the value of 1(off) and 2(ac0Sec), this implementation is allowed.
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), ac0Sec(2), ac10Sec(3), ac20Sec(4), ac30Sec(5), ac60Sec(6), ac90Sec(7), ac120Sec(8)  

mltPrtPaperTimeOut 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.4
Setting which decides whether automatic recover should be proceed or not when an error related to paper occurred.
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), proceedJob(2), cancelJob(3)  

mltPrtPsErrorPrint 1.3.6.1.4.1.2590.1.1.1.1.6.5.1.1.5
The setting whether the printer prints PostScript Error Page when PostScript Error occurred during job processing. About PS error, since it is the function of a printer controller, all the devices with PS should be implemented If a device has no PostScript interpreter, this value should be always notSupported(0) as RO.
OBJECT-TYPE    
  INTEGER notSupported(0), off(1), on(2)  

mltPrtPrintConfigTable 1.3.6.1.4.1.2590.1.1.1.1.6.5.2
A table of configurations for printer. This table must be implemented even if no functions in this table are supported.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPrintConfigEntry

mltPrtPrintConfigEntry 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'
OBJECT-TYPE    
  MltPrtPrintConfigEntry  

mltPrtCopies 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.1
The number of printing copies. If set value is over limit, printer should return error. About device which has no PCL interpreter, This value should be -1, because of no default copies setting.
OBJECT-TYPE    
  INTEGER  

mltPrtPaperSize 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.2
Paper size of printing. The value of the mltPaperSizeIndex corresponding to the current paper size. About device which has no PCL interpreter, This value should be -1, because of no default paper size setting.
OBJECT-TYPE    
  INTEGER  

mltPrtPaperSource 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.3
Feeders for printing. The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. If value is 0, this means 'Auto'. About device which has no PCL interpreter, This value should be -1, because of no default paper source setting.
OBJECT-TYPE    
  INTEGER  

mltPrtFineArt 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.4
Smooting setting. If printer has no smoothing function, this value should be notSupported(0) and RO. If printer supports only On/Off , this value should be on(1) or offSwitch(2). If printer supports 4 steps, this value should be dark(3), medium(4), light(5) and offStep(6).
OBJECT-TYPE    
  INTEGER notSupported(0), on(1), offSwitch(2), dark(3), medium(4), light(5), offStep(6)  

mltPrtTonerSave 1.3.6.1.4.1.2590.1.1.1.1.6.5.2.1.5
Toner saving setting. If printer is not supporting toner save function, this value should be notSupported(0) and RO. If printer is supporting toner save function, this value should be on(1) or off(2) and RW.
OBJECT-TYPE    
  INTEGER notSupported(0), on(1), off(2)  

mltPrtFont 1.3.6.1.4.1.2590.1.1.1.1.6.6
OBJECT IDENTIFIER    

mltPrtPclFontTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.1
This table shows PCL font information of printer has. Since it is a function peculiar to PCL, it is not necessary to implement this table in the device in which PCL is not installed or PCL font management function is not installed.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPclFontEntry

mltPrtPclFontEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1
Information about printer's PCL fonts. Entries may exist in the table for each device index whose device type is 'printer'.
OBJECT-TYPE    
  MltPrtPclFontEntry  

mltPrtPclFontIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.1
A unique value used to identify this entry.
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtPclFontName 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.2
The name of PCL Font.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltPrtPclFontNumber 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.3
The number of PCL Font. The number for managing the font, which a printer holds inside.
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPclFontSource 1.3.6.1.4.1.2590.1.1.1.1.6.6.1.1.4
The information of a place that PCL font exists.
OBJECT-TYPE    
  INTEGER unknown(0), internalRom(1), internalHd(2), downLoadRam(3), downLoadHd(4), downLoadFlashRom(5)  

mltPrtPsFontTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.2
This table shows PostScript font information of printer has. Since it is a function peculiar to PS, it is not necessary to implement this table in the device in which PS is not installed.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPsFontEntry

mltPrtPsFontEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1
Information about printer's PS fonts. Entries may exist in the table for each device index whose device type is 'printer'.
OBJECT-TYPE    
  MltPrtPsFontEntry  

mltPrtPsFontIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.1
A unique value used to identify this entry.
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtPsFontName 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.2
The name of PS Font.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltPrtPsFontNumber 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.3
The number of PS Font. This number is used in order to administrate printer's fonts. If a printer does not manage this number, this value should be implemented same as mltPrtPsFontIndex.
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPsFontSource 1.3.6.1.4.1.2590.1.1.1.1.6.6.2.1.4
The information of a place that PS font exists
OBJECT-TYPE    
  INTEGER unknown(0), internalRom(1), internalHd(2), downLoadRam(3), downLoadHd(4), downLoadFlashRom(5)  

mltPrtSymbolSetTable 1.3.6.1.4.1.2590.1.1.1.1.6.6.3
This table shows symbol sets a printer has. If no function in this table is supported by a device, this table needs not to be implemented.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtSymbolSetEntry

mltPrtSymbolSetEntry 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1
Information about printer's symbol sets. Entries may exist in the table for each device index whose device type is 'printer'.
OBJECT-TYPE    
  MltPrtSymbolSetEntry  

mltPrtSymbolSetIndex 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.1
A unique value used to identify this entry.
OBJECT-TYPE    
  INTEGER 1..65535  

mltPrtSymbolSetName 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.2
The name of SymbolSet (CodedCharSet).
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltPrtCharSetID 1.3.6.1.4.1.2590.1.1.1.1.6.6.3.1.3
The ID of Code CharSet. Refer to the following URL that IANA administrates regarding character code sets: http://www.iana.org/assignments/character-sets
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPaper 1.3.6.1.4.1.2590.1.1.1.1.6.7
OBJECT IDENTIFIER    

mltPrtPaperSizeTable 1.3.6.1.4.1.2590.1.1.1.1.6.7.1
A table of the printer selectable paper sizes. Even if a printer can not recognize the supportable paper, one object ('unknown' or 'other') must be loaded at least.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtPaperSizeEntry

mltPrtPaperSizeEntry 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is 'printer'
OBJECT-TYPE    
  MltPrtPaperSizeEntry  

mltPaperSizeIndex 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.1
A unique value used to identify this entry.
OBJECT-TYPE    
  INTEGER 1..65535  

mltPaperSizeName 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.2
The name of paper size. e.g., letter, legal, A4, B5 etc.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltPaperFeedDir 1.3.6.1.4.1.2590.1.1.1.1.6.7.1.1.3
This value shows paper feeding orientation.
OBJECT-TYPE    
  INTEGER other(0), sef(1), lef(2)  

mltPrtRemotePanel 1.3.6.1.4.1.2590.1.1.1.1.6.10
OBJECT IDENTIFIER    

mltPrtRemotePanelButtonTable 1.3.6.1.4.1.2590.1.1.1.1.6.10.1
A table of printer's remote operational panel button.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrtRemotePanelButtonEntry

mltPrtRemotePanelButtonEntry 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1
An entry exists in this table for each device entry in the hostmib device table whose type is `printer'
OBJECT-TYPE    
  MltPrtRemotePanelButtonEntry  

mltPrtPanelButtonIndex 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.1
A unique value used by the operational panel button to identify table
OBJECT-TYPE    
  INTEGER 0..65535  

mltPrtPanelButtonName 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.2
The name of panel button.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltPrtPanelButtonPush 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.3
This value indicates panel button status, and make pushing button. noAction (0) -- indicate steady. push (1) -- To set 1 means push panel button. longPush (2) -- To set 2 means push button long time. shiftPush (3) -- To set 3 means push panel bottom and shift button same time.
OBJECT-TYPE    
  INTEGER noAction(0), push(1), longPush(2), shiftPush(3)  

mltPrtPanelButtonDescr 1.3.6.1.4.1.2590.1.1.1.1.6.10.1.1.4
An explanation of panel button function etc.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltSysMib 1.3.6.1.4.1.2590.1.1.1.5
OBJECT IDENTIFIER    

mltSysMibVersion 1.3.6.1.4.1.2590.1.1.1.5.1
The version information of Standard MIB specification. This indicates the version of the Private System MIB which is implemented. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
OBJECT-TYPE    
  DisplayString SIZE(0..7)  

mltSysGeneralInfo 1.3.6.1.4.1.2590.1.1.1.5.2
OBJECT IDENTIFIER    

mltSysPriorityDevice 1.3.6.1.4.1.2590.1.1.1.5.2.2
This object shows the function which operates with highest priority in a system. When it can set up by user choice etc., it should be RW. If setup change is impossible from MIB, the implementation of RO is acceptable. There is no function with highest priority or no preference order of function, implement RO as 0.
OBJECT-TYPE    
  INTEGER  

mltSysCurrentDateTime 1.3.6.1.4.1.2590.1.1.1.5.2.4
Time, which is set in the system and specifies by DateAndTime If not having a clock function, implement 0x00 in all Bytes.
OBJECT-TYPE    
  DateAndTime  

mltSysContact 1.3.6.1.4.1.2590.1.1.1.5.3
OBJECT IDENTIFIER    

mltSysContactSiteName 1.3.6.1.4.1.2590.1.1.1.5.3.1
The name of a support contact for system. If device cannot support this object, device should be implement '-' as read-only
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

mltSysContactInfo 1.3.6.1.4.1.2590.1.1.1.5.3.2
Explanation of a support contact for system. Default value shall be a blank, and a service person or a user shall input it. If device cannot support this object, device should be implement '-' as read-only
OBJECT-TYPE    
  DisplayString SIZE(0..128)  

mltSysProductHelpURL 1.3.6.1.4.1.2590.1.1.1.5.3.3
URL of the support contact for system. If device cannot support this object, device should be implement '-' as read-only
OBJECT-TYPE    
  DisplayString SIZE(0..128)  

mltSysCorpURL 1.3.6.1.4.1.2590.1.1.1.5.3.4
URL of the company which provides a system. If device cannot support this object, device should be implement '-' as read-only
OBJECT-TYPE    
  DisplayString SIZE(0..128)  

mltSysSuppliesInfo 1.3.6.1.4.1.2590.1.1.1.5.3.5
A telephone number or E-mail addresses for the supplies and accessories, etc. In the support contact in which a system has. Default shall be a blank, and a service person or a user shall input it. If device cannot support this object, device should be implement '-' as read-only
OBJECT-TYPE    
  DisplayString SIZE(0..128)  

mltSysVersion 1.3.6.1.4.1.2590.1.1.1.5.5
OBJECT IDENTIFIER    

mltSysVersionTable 1.3.6.1.4.1.2590.1.1.1.5.5.1
The table for showing ROM and F/W version in which a system has.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysVersionEntry

mltSysVersionEntry 1.3.6.1.4.1.2590.1.1.1.5.5.1.1
The version information of FW or ROM.
OBJECT-TYPE    
  MltSysVersionEntry  

mltSysVersionIndex 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.1
Index for uniquely showing the version information in which a system has. The number and the order of index depends on an implementation of a model. Implement the maximum number of index of ROM and F/W which is possible to detect/display, regardless of the availability of installation of Option etc. The number of indexes to hold shall be always fixed regardless of the option installation state.
OBJECT-TYPE    
  INTEGER  

mltSysVerName 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.2
The name of the function which shows a version. For example, 'MSC/Panel ROM Version', 'Printer ROM Version', etc.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltSysVersionCode 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.3
The version of ROM and F/W. It shall be written by 15 or less characters. '[Product Code(4)]-[Block Code(2)][Stage Code(1)] [Specification Code(1)]-[Change Management Code(2)] -[Shipment Destination Code(2)]' supports. For corresponding to the other written methods, it was made into the maximum 31 characters, on the definition. When the value cannot acquire although index is set by Option etc., display '-' (hyphen).
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltSysVerDescr 1.3.6.1.4.1.2590.1.1.1.5.5.1.1.4
Explanation of a version. As for the contents to indicate, depends on an implementation of a model. However, since not supporting this object is not acceptable, implement Null (Zero-Length) at least.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltSysComponent 1.3.6.1.4.1.2590.1.1.1.5.6
OBJECT IDENTIFIER    

mltSysCompConfigID 1.3.6.1.4.1.2590.1.1.1.5.6.1
Shows the ID by the combination of the structure of Device. A project should prepare ID which is worth for the number of combination, such as Option. If system has no option or cannot detect option installed, this value should be always 0.
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayTable 1.3.6.1.4.1.2590.1.1.1.5.6.2
The table for showing the information of Input tray that is installed in a system. As a principle, the un-acquirable information shall be displayed if there is only prtInputTable, and this table is premised on that PrinterMIB is being implemented. It shall display about InputTray which is installed like prtInputTable. If a system does not have a printer engine (has no input tray and no PrinterMIB), this table does not need to implement.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysInputTrayEntry

mltSysInputTrayEntry 1.3.6.1.4.1.2590.1.1.1.5.6.2.1
The information of paper input tray.
OBJECT-TYPE    
  MltSysInputTrayEntry  

mltSysInputTrayIndex 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.1
Index for showing InputTray in a system. Index depends on the state of the implementation of a model, and shall be taken the amount which is worth for the number of InputTray in the order from 1.
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayRefIndex 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.2
The value of prtInputIndex of a tray which mltSysInputTrayIndex shows.
OBJECT-TYPE    
  INTEGER  

mltSysInputTrayName 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.3
The name of InputTray. Default value depends on a model. In principle, use the name unified by DriverUI. Set of the character string up to 15 characters shall be possible. implementation of RO is also accepted when there are capacity restrictions of NVRAM. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltSysInputTrayCapacitySence 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.4
This item shows the detection method of paper residual quantity, and is used for distinction of the value displayed in prtInputCurrentLevel. The details of a residual quantity display are indicated to prtInputCurrentLevel.
OBJECT-TYPE    
  INTEGER noSensor(0), emptyOnly(1), nearEmpty(2), linearSense(3)  

mltSysInputTraySpecialPaper 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.5
Shows the media type of InputTray. If this value is RW and when a setup is changed by MIB, it shall be reflected in a setup of a printer engine. In a unavoidable case, the access way may be RO.
OBJECT-TYPE    
  INTEGER other(0), unknown(1), plainPaper(10), plainPaper-NotFor2Sided(11), plainPaper-Recycled(12), plainPaper-Exclusive(14), plainPaper-Color(16), thick(20), thick1(22), thick1-2side(23), thick2(24), thick2-2side(25), thick3(26), thick3-2side(27), ohp(30), thin(36), envelope(40), envelope-2side(41), label(42), postCard(44), letterHead(46), tab(48)  

mltSysInputTrayPaperAttribute 1.3.6.1.4.1.2590.1.1.1.5.6.2.1.6
Shows the paper attribute of InputTray. If this value is RW and when a setup is changed by MIB, it shall be reflected in a setup of a printer engine. In a unavoidable case, the access way may be RO.
OBJECT-TYPE    
  INTEGER notSupported(0), s0-normalPaper(1), s1-recyclePaper(2), s2-specialPaper(3), s3-reusePaper(4)  

mltSysOutputTrayTable 1.3.6.1.4.1.2590.1.1.1.5.6.3
The table for showing the information of OutputTray relation in a system. Index shall be mltSysOutputTrayIndex. This table is for displaying the tray information of OutputOption (Finisher), and shall not include the function information of Finisher. If a system does not have a printer engine (has no output tray and no PrinterMIB), this table may not be implemented.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysOutputTrayEntry

mltSysOutputTrayEntry 1.3.6.1.4.1.2590.1.1.1.5.6.3.1
The information of paper output tray.
OBJECT-TYPE    
  MltSysOutputTrayEntry  

mltSysOutputTrayIndex 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.1
Index for showing OutputTray in a system. Index depends on the implementation of a model, and shall be taken the amount which is worth for the number of Output in the order from 1. In principle, when the top tray is set as 1, index shall be increased in progress of going to the lower part. As for the middle processing tray that does not become papers' final output destination, is not treated as OutputTray.
OBJECT-TYPE    
  INTEGER  

mltSysOutputTrayRefIndex 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.2
Value of prtOutputIndex of the tray which mltSysOutputTrayIndex shows.
OBJECT-TYPE    
  INTEGER  

mltSysOutputTrayDefaultName 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.3
The name of OutputTray. Unify with the notation of a manual or a driver.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltSysOutputTrayNickName 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.4
The name of OutputTray in which a user can set up. In MailBin, use it in order to indicate a user's name, etc. which each Tray set up. The recommendation default is the same as mltSysOutputTrayDefaultName. Set of the character string up to 15 characters shall be possible, and neither retrenchment of the number of characters which can be written in, nor implementation of RO shall be accepted. However, the implementation of RO is accepted only to the thing without MailBin as OutputOption. Moreover, being reflected in the display screen of a printer driver is desirable. Since this item is the value used when a user does a remote management, it is not necessary to link it with a setup of a printer engine. SNMP agent holds value, and should just provide the convenience to the user who remote accesses. If device cannot support this function, this object should be '-' as ReadOnly.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltSysOutputTrayType 1.3.6.1.4.1.2590.1.1.1.5.6.3.1.5
Shows the type of tray in OutputTray. This is an item for judging whether it is MailBin, and it is used in order to judge whether the writing of NickName should be possible.
OBJECT-TYPE    
  INTEGER other(0), standardBin(1), sortBin(3), mailBox(4), fixedMailBin(5)  

mltSysCounter 1.3.6.1.4.1.2590.1.1.1.5.7
OBJECT IDENTIFIER    

mltSysCounterConfig 1.3.6.1.4.1.2590.1.1.1.5.7.1
OBJECT IDENTIFIER    

mltSysSupportedCounterType 1.3.6.1.4.1.2590.1.1.1.5.7.1.1
Shows the type of a counter installed in a system. The counter which a system has can specify by referring to this. Displays the counter to support with Bitmap and shows the supporting counter by the total. Bit Value CounterType --- ----- --------------- 0 1 GeneralCounter 1 2 PrintFunctionCounter 2 4 SendFunctionCounter 3 8 PapersSizeCounter 4 16 DivCounter 5 32 TonerLifeCounter It becomes 63 when implementing all the counters.
OBJECT-TYPE    
  INTEGER  

mltSysDuplexCountMode 1.3.6.1.4.1.2590.1.1.1.5.7.1.2
Sets up whether Duplex printing is counted two times to TotalCounter at the time. This setup is reflected to all TotalCounters. This object may be implemented with RO access. If a system doesn't have this setting (e.g. printer), the value of the static count mode (1 or 2) must be implemented. Basically this value must not be '0'. This is also applied to mtSysLargeSizeCountMode and mltSysLargeSizeMode same.
OBJECT-TYPE    
  INTEGER unknown(0), singleCount(1), doubleCount(2)  

mltSysLargeSizeCountMode 1.3.6.1.4.1.2590.1.1.1.5.7.1.3
Sets up whether LargeSize is counted two times to TotalCounter at the time. This setup is reflected to all TotalCounters. This object may be implemented with RO access. This setting is the item of a service choice. A setup of a service choice is reflected to this object. Also enable operation from PageScope. Management of the access rights supports by PageScope side.
OBJECT-TYPE    
  INTEGER unknown(0), singleCount(1), doubleCount(2)  

mltSysLargeSizeType 1.3.6.1.4.1.2590.1.1.1.5.7.1.4
Sets up the type of paper counted as LargeSize. noLargeSize(0): indicates that the count of LargeSize is not performed or not detect large size type. typeA(1): For US is 11x17, For EU is A3, For Japan is A3. typeB(2): For US is 11x17, For EU is A3/B4, For Japan is A3/B4. typeC(3): For US is 11x17/11x14/8.5x14, For EU is A3/B4, For Japan A3/B4. This object may be implemented with RO access. The choice item of EP-NET. Also enable operation from PageScope.
OBJECT-TYPE    
  INTEGER noLargeSize(0), typeA(1), typeB(2), typeC(3)  

mltSysColorCountSupportType 1.3.6.1.4.1.2590.1.1.1.5.7.1.5
It is shown what kind of counter by the color is supported. The color counter which a device supports can be specified by referring to this. Displays the type of counter to support with Bitmap and shows the supporting counter by the total. The type counter that is shown in here shall be held by the color-related counter. Bit Value CounterType --- ----- ----------------- 0 1 reserved 1 2 bw --The monochrome counter --in a color machine 2 4 fourColor (4c) --Full color -- (All of C, M, Y, and K are used) 3 8 threeColor (3c) --Monochrome color --(monochrome is taken out using -- three colors of C, M, and Y) 4 16 cmy --CMY: (using any 1 color of C/M/Y) 5 32 rgb --RGB: (using three colors of CMY) 6 64 monoColor --The total of 3C, CMY, and RGB 7 128 paperPath --PaperPath counter
OBJECT-TYPE    
  INTEGER  

mltSysSystemCounter 1.3.6.1.4.1.2590.1.1.1.5.7.2
OBJECT IDENTIFIER    

mltSysGeneralCounter 1.3.6.1.4.1.2590.1.1.1.5.7.2.1
OBJECT IDENTIFIER    

mltSysTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.1
The total print count of a system. Displays the total of Copy, Print, and Receiving Job. About the count method of Duplex and LargeSize, it depends on a setup. A count shall be an output count. About a color machine, it shall be the total of all color classifications.
OBJECT-TYPE    
  Integer32  

mltSysLargeSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.2
The total print count of LargeSize paper. About the type of LargeSize, it depends on a setup of mltSysLargeSizeType. When the setup of mltSysLargeSizeType is noCount(0), this counter always shall be -1. In addition, also in the system without A4 machine, etc., this counter should be -1.
OBJECT-TYPE    
  Integer32  

mltSysDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.3
The total print count of Duplex (back). In the system without Duplex mechanism, it should be -1.
OBJECT-TYPE    
  Integer32  

mltSysLargeDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.4
The total print count of LargeSize, and also Duplex (back). About the type of LargeSize, it depends on a setup of mltSysLargeSizeType. When the setup of mltSysLargeSizeType is noCount(0), this counter always shall be -1. In addition, in the system of A4 machine or in the system without Duplex, this counter always should be -1.
OBJECT-TYPE    
  Integer32  

mltSysSendTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.5
Total count scaned as a transmitting function in the system. It shall be the total of mltSysSendScanCount. In the device without Scan function, it always shall be -1.
OBJECT-TYPE    
  Integer32  

mltSysTotalJamCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.6
The number of times of Jam occurred in the system. It shall be the total of all Jam counters. (including ADF jams).
OBJECT-TYPE    
  Integer32  

mltSysTotalTroubleCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.1.7
The number of times of Trouble (FatalError) occurred in the system. It shall be the total of all Trouble counters.
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.2
The table for showing the counter by the color and function. In the monochrome machine of a single function, it is not necessary to implement.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysPrintFunctionCounterEntry

mltSysPrintFunctionCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1
The counters of color and print functions.
OBJECT-TYPE    
  MltSysPrintFunctionCounterEntry  

mltSysPrintFunctionColorIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.1
Index for showing the color in the counter by color/function. By the color, index shall be attached in the order of the following. No. Function -------------------- 1 BW 2 4C 3 3C 4 CMY 5 RGB 6 MonoColor
OBJECT-TYPE    
  INTEGER  

mltSysPrintFunctionIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.2
Index for showing the function in the counter by color/function. By the function, index shall be attached in the order of the following. No. Function -------------------- 1 copy 2 printer 3 received Job 4 fax received Job 5 reportPrint Although classifying into printer/receive Job/fax receive job as a printing function is recommended, the implementation of multiple counting as a printer function is also accepted.
OBJECT-TYPE    
  INTEGER  

mltSysPrintFunctionColorType 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.3
Shows the color mode in the counter by color/function.
OBJECT-TYPE    
  INTEGER bw(1), fourColor(2), threeColor(3), cmy(4), rgb(5), monoColor(6), paperPath(7)  

mltSysPrintFunctionType 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.4
Shows the function in the counter by color/function. Although classifying into printer/receive Job/fax receive job as a printing function is recommended, the implementation of multiple counting as a printer function is also accepted.
OBJECT-TYPE    
  INTEGER copyFunction(1), printFunction(2), receiveFunction(3), faxReceiveFunction(4), reportPrint(5)  

mltSysPrintFunctionTotalCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.5
The total print count in a specified function. About the count method, complies with GeneralCounter
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.6
The print count of Duplex (back) in a specified function. The print count of the LargeSize paper in a specified function. About the count method, complies with GeneralCounter.
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionLargeSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.7
The print count of the LargeSize paper in a specified function. About the count method, complies with GeneralCounter.
OBJECT-TYPE    
  Integer32  

mltSysPrintFunctionLargeDuplexCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.2.1.8
The print count of LargeSize and Duplex (back) in a specified function. About the count method, complies with GeneralCounter.
OBJECT-TYPE    
  Integer32  

mltSysSizeCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.4
The table of the counter by the paper sizes (types). The model which supports plural paper sizes has to implement. Regardless of shipment destination, having a counter to all the paper sizes that can be printed is recommended. By implementation, implementing different size counter by shipment destination is also accepted. It shall also have index by the functions so that it can correspond to the counter by sizes by the functions.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysSizeCounterEntry

mltSysSizeCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1
The information of paper size counters.
OBJECT-TYPE    
  MltSysSizeCounterEntry  

mltSysSizeFunctionIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.1
Index for showing the function which becomes the count object in the counter by paper sizes. Although Index shall be attached in the order of the following by the function, having Index by fixation shall not require. No. Function -------------------- 1 Total
OBJECT-TYPE    
  INTEGER  

mltSysSizeTypeIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.2
Index for showing the paper which becomes the count object in the counter by paper sizes. Only the type of corresponding paper shall be taken in the order from 1. Using fixed index for every paper does not require.
OBJECT-TYPE    
  INTEGER  

mltSysSizeFunction 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.3
Shows the function which becomes the count object in the counter by paper size.
OBJECT-TYPE    
  INTEGER total(0)  

mltSysSizeType 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.4
Shows the paper which becomes the count object in the counter by paper sizes.
OBJECT-TYPE    
  INTEGER otherPaperSize(0), unknownPaperSize(1), a0(11), a1(12), a2(13), a3(14), a4(15), a5(16), a6(17), b0(21), b1(22), b2(23), b3(24), b4(25), b5(26), b6(27), us12x14(30), ledger(31), us11x15(32), us11x14(33), comp(34), us10x14(35), us9-1by4x14(36), legal(37), us8-1by4x11-3by4(38), letter(39), govermentLetter(40), quarto(41), executive(42), statement(43), fls(50), fls0(51), fls1(52), fls2(53), fls3(54), hagaki(61), oufuku-Hagaki(62), envelopeB5(63), envelopeCom10(64), envelopeC5(65), envelopeDL(66), envelopeMonarch(67), envelopeC6(68), youkei-0Gou(70), youkei-4Gou(71), youkei-6Gou(72), choukei-3Gou(83), choukei-4Gou(84), kakugata-3Gou(93), special0(100), special1(101), special2(102), special3(103), special4(104), special5(106), a3W(114), a4W(115), a5W(116), a6W(117), otherPaperAttribute(199), unknownPaperAttribute(200), plain(201), exclusive(202), notFor2Sided(203), specialPaper(204), cover(205), inserter(206), reuse(207), otherMediaType(208), unknownMediaType(209), plainPaper(210), plainPaper-2side(211), plainPaper-Recycled(212), plainPaper-Exclusive(214), plainPaper-Color(216), thick1(222), thick1-2side(223), thick2(224), thick2-2side(225), thick3(226), thick3-2side(227), ohp(230), thin(236), envelope(240), envelope-2side(241), label(242), postCard(244), letterHead(246), tab(248)  

mltSysSizeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.4.1.5
The number of print of the specified function and specified size, media type, or attribute.
OBJECT-TYPE    
  Integer32  

mltSysTonerLifeCounterTable 1.3.6.1.4.1.2590.1.1.1.5.7.2.5
The table of toner life counter.
OBJECT-TYPE    
  SEQUENCE OF  
    MltSysTonerLifeCounterEntry

mltSysTonerLifeCounterEntry 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1
The information of toner life counters.
OBJECT-TYPE    
  MltSysTonerLifeCounterEntry  

mltSysTonerTypeIndex 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.1
Index for Toner used as the count object in TonerLife counter being shown.
OBJECT-TYPE    
  INTEGER  

mltSysTonerType 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.2
Toner used as the count object in TonerLife counter is shown.
OBJECT-TYPE    
  INTEGER other(0), cyan(1), magenta(2), yellow(3), black(4)  

mltTonerTypeCount 1.3.6.1.4.1.2590.1.1.1.5.7.2.5.1.3
TonerLife count. This is used for calculation of Coverage, by the amount of Toner consumption, etc. by counting Dot number used for every Toner. 1unit is 2M Dots.
OBJECT-TYPE    
  Counter32  

mltInterface 1.3.6.1.4.1.2590.1.1.2
OBJECT IDENTIFIER    

mltNetwork 1.3.6.1.4.1.2590.1.1.2.1
OBJECT IDENTIFIER    

mltNetworkMib 1.3.6.1.4.1.2590.1.1.2.1.5
OBJECT IDENTIFIER    

mltNetMibVersion 1.3.6.1.4.1.2590.1.1.2.1.5.1
The standardization version of MIB implemented in Network. This indicates the version of the Private Network MIB. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
OBJECT-TYPE    
  DisplayString SIZE(0..7)  

mltNetGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.2
OBJECT IDENTIFIER    

mltNetGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.2.1
Table for showing the general information of Network relation.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetGeneralEntry

mltNetGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1
General information of network interface.
OBJECT-TYPE    
  MltNetGeneralEntry  

mltNetGeneralIndex 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.1
Index for showing NetworkInterface installed to a device. Basically, it shall take the same value with ifIndex.
OBJECT-TYPE    
  INTEGER  

mltNetFirmVersion 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.2
Shows the FW version of NetworkInterface. Write it as ##.xx. ## shall be a major version and xx shall be a minor version. If there is no original FW of NetworkInterface, implement character strings of '-' (hyphen).
OBJECT-TYPE    
  DisplayString SIZE(0..7)  

mltNetHardwareAddress 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.3
MAC address of NetworkInterface. (Hardware address) In the device of our company, it was made into RW since MAC address needs to be written at the time of shipment. Implement as RO when the writing of MAC address is unnecessary. Moreover, in a management tool side, be sure to handle it as RO.
OBJECT-TYPE    
  PhysAddress  

mltNetSerialNumber 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.4
The serial number of NetworkInterface. Implement '-' (hyphen) in the device without a serial number. In the device of our company, it was made into RW since serial number may need to be written at the time of shipment. Implement as RO when the writing of serial number is unnecessary. Moreover, in a management tool side, be sure to handle it as RO.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetSupportedConnector 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.5
An integer bitmap value specifying network connector information. Each bit in the integer is defined as follows. bit Value Connector --- ----- --------- 0 1 Reserved 1 2 Ethernet AUI -- 10Base5 2 4 Ethernet BNC -- 10Base2 3 8 Ethernet RJ45 -- 10/100BaseT 4 16 Ethernet Fiber -- 10/100BaseF 5 32 Reserved 6 64 Reserved 7 128 TokenRing STP(DB-15) 8 256 TokenRing UTP(RJ-45) 9 512 TokenRing Fiber 10 1024 Reserved 11 2048 wirelessA -- 802.11a 12 4096 wirelessB -- 802.11b 13 8132 blueTooth 14 16364 ieee1394 -- IP over IEEE1394
OBJECT-TYPE    
  INTEGER  

mltNetCurrentConnector 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.6
Shows the connector that is working on NetworkInterface.
OBJECT-TYPE    
  INTEGER notWorking(0), etherAUI(1), etherBNC(2), etherRJ(3), etherFiber(4), tokenSTP(7), tokenUTP(8), tokenFiber(9), wirelessA(11), wirelessB(12), blueTooth(13), ieee1394(14)  

mltNetSpeedConfig 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.7
Sets up the speed of NetworkInterface. Refer to ifSpeed for checking the present speed of operation. If this setting can not be set from Network access, a device should implement a current set value with RO access.
OBJECT-TYPE    
  INTEGER other(0), autoDetectEther(1), et10MbpsHalfDuplex(2), et10MbpsFullDuplex(3), et100MbpsHalfDuplex(4), et100MbpsFullDuplex(5), etGbpsHalfDuplex(6), etGbpsFullDuplex(7), autoDetectToken(10), tr4Mbps(11), tr16Mbps(12), tr32Mbps(13), autoDetectWireless(20), wireless1Mbps(21), wireless2Mbps(22), wireless5-5Mbps(23), wireless11Mbps(24)  

mltNetInterfaceType 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.8
Shows the type of NetworkInterface.
OBJECT-TYPE    
  INTEGER other(0), ieee1284(1), ieee1394(2), usb(3), dual1284(10), dpo(11), psio(12), onBoardDPO(100), noPhysicalNIC(101), onBoard(102), onBoardOneChip(103), onBoardPSIO(104), pciNonIntelligent(201), pciIntelligent(202)  

mltNetIfDescr 1.3.6.1.4.1.2590.1.1.2.1.5.2.1.1.9
Explanation of NetworkInterface. Shows the type of port and the version information. The name to indicate is determined at Project side and implementation of NullString is not accepted. Even if a device have a no description about this, '-' need to be implemented.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetProtocol 1.3.6.1.4.1.2590.1.1.2.1.5.3
OBJECT IDENTIFIER    

mltNetProtocolTable 1.3.6.1.4.1.2590.1.1.2.1.5.3.1
The table for showing the protocol information which NetworkInterface supports.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetProtocolEntry

mltNetProtocolEntry 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1
The information of protocol.
OBJECT-TYPE    
  MltNetProtocolEntry  

mltNetProtocolIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.1
Index for showing NetworkInterface that a system has. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetProtocolIndex 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.2
Index for uniquely showing the protocol which a system supports. Index shall be assigned in the following order is recommended. No. Protocol -------------------- 1 TCP/IP 2 NetWare(IPX/SPX) 3 AppleTalk 4 SMB
OBJECT-TYPE    
  INTEGER  

mltNetProtocolType 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.3
Shows the type of supporting protocol.
OBJECT-TYPE    
  INTEGER unknown(0), tcp-ip(1), netWare(2), appleTalk(3), smb(4), other(7)  

mltNetProtocolDescr 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.4
Description that shows a protocol. Although the value to indicate shall depend on an implementation, the general protocol name, such as 'TCP/IP', 'NetWare', etc., shall be indicated in principle. Implementation of Null is not accepted.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetProtocolVer 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.5
The version of the implemented protocol stack. Implement '-' (hyphen) when there is no version notation. Implementation of Null is not accepted.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetProtocolOnOff 1.3.6.1.4.1.2590.1.1.2.1.5.3.1.1.6
Sets up a states display of On and Off of the function of each protocol. If this setting can not be set from Network access, a device should implement a current set value with RO access.
OBJECT-TYPE    
  INTEGER notSupported(0), enable(1), disable(2)  

mltNetCommand 1.3.6.1.4.1.2590.1.1.2.1.5.5
OBJECT IDENTIFIER    

mltNetCommandTable 1.3.6.1.4.1.2590.1.1.2.1.5.5.1
The table for showing the command information which NetworkInterface supports.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetCommandEntry

mltNetCommandEntry 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1
The information of command for network interface.
OBJECT-TYPE    
  MltNetCommandEntry  

mltNetCommandIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.1
Index for uniquely showing the destination of command. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetCommandReset 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.2
The command that performs independent reset of NetworkInterface. When reset(2) is set, an agent side shall surely return Reply. Implementation that performs Reset immediately without returning Reply is not accepted. Return Reply of an error, when Reset command is invalid. After reset(2) is set, about the timing which is actually performing Reset depends on an implementation, and it shall not be defined in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), reset(2)  

mltNetCommandDefault 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.3
The command for returning a setup about NetworkInterface to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetCommandPrintNicConfig 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.4
The command for making it perform the output of ConfigPage which Network Interface has at the time of normal operation. Independent ConfigPage of two or more kinds of Network is not considered.
OBJECT-TYPE    
  INTEGER notSupported(10), supported(11), printing(12)  

mltNetCommandStartupConfig 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.5
The command that sets up the availability of the output of ConfigPage of NetworkInterface at the time of starting. Independent StartupPage of two or more kinds of Network is not considered.
OBJECT-TYPE    
  INTEGER notSupported(10), supported(11), printStartUp(12)  

mltNetCommandDownLoad 1.3.6.1.4.1.2590.1.1.2.1.5.5.1.1.6
The command that sets up the mode that updates FW of NetworkInterface. Since this setup needs to operate with Admin authority, do not perform both display and writing at the management tool side.
OBJECT-TYPE    
  INTEGER notSupported(0), notDownLoad(1), downLoading(2)  

mltNetSnmp 1.3.6.1.4.1.2590.1.1.2.1.5.6
OBJECT IDENTIFIER    

mltNetSnmpCommTable 1.3.6.1.4.1.2590.1.1.2.1.5.6.1
The table for showing the information of Community of SNMP which a system has. In addition, Community name shall be the common to the whole system on the premise, and shall not have independent Community for every NetworkInterface. In having Community independently by Intelligent NIC etc., it shall have NetworkMIB independently to each and is not managed by unified agent.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSnmpCommEntry

mltNetSnmpCommEntry 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1
OBJECT-TYPE    
  MltNetSnmpCommEntry  

mltNetSnmpCommIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.1
Index for identifying each SNMP community. Although about Community number to support, Community name, and each access rights are dependent on an implementation, having the following three Communities is recommended. public (RO) private (RW) admin (RW) It shall be indispensable at least to have public (RW) or to have the two of public (RO) and private (RW).
OBJECT-TYPE    
  INTEGER  

mltNetSnmpCommName 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.2
Community name of SNMP. Having the above-mentioned name as default is recommended. This item does not accept the implementation of RO. Community name has to be changeable. But if Community name can not be changeable, 'public' or 'private' is recommended to be implemented as Community name with RO access.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetSnmpCommAccessRight 1.3.6.1.4.1.2590.1.1.2.1.5.6.1.1.3
Shows the access rights of SNMP community. If this setting can not be set from Network access, a device should implement a current set value with RO access.
OBJECT-TYPE    
  INTEGER none(0), readOnly(1), writeOnly(2), readWrite(3)  

mltNetSnmpTrapTable 1.3.6.1.4.1.2590.1.1.2.1.5.6.2
The table for showing the information of destination of Trap of SNMP. When it does not have Trap function of SNMP, this Table does not need to implement.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSnmpTrapEntry

mltNetSnmpTrapEntry 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1
OBJECT-TYPE    
  MltNetSnmpTrapEntry  

mltNetSnmpTrapIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.1
The index for uniquely showing the NetworkInterface which becomes the sender of Trap. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSnmpTrapIndex 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.2
The index for uniquely showing the destination of Trap. In Default, it shall have at least one TrapAddress in a Table.
OBJECT-TYPE    
  INTEGER  

mltNetSnmpTrapCommunity 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.3
Community name at the time of transmitting Trap. In Default, it shall have public. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetSnmpTrapIpAddress 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.4
IP address of Trap destination. It shall be 255.255.255.255 (BroadCast) in Default. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  IpAddress  

mltNetSnmpTrapIpxAddress 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.5
IPX address of the destination of Trap. It shall be 'FFFFFFFF:FFFFFFFFFFFFFFFF' in Default. When it does not have Trap transmitting function in IPX, the character string of '-' (hyphen) shall be displayed. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSnmpTrapOnOff 1.3.6.1.4.1.2590.1.1.2.1.5.6.2.1.6
On/Off of transmission of Trap is controlled. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

mltNetTcpip 1.3.6.1.4.1.2590.1.1.2.1.5.7
OBJECT IDENTIFIER    

mltNetTcpipGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.7.1
OBJECT IDENTIFIER    

mltNetTcpipGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1
Table with the basic information of TCP/IP relation which NetworkInterface has.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetTcpipGeneralEntry

mltNetTcpipGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1
OBJECT-TYPE    
  MltNetTcpipGeneralEntry  

mltNetTcpipIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.1
Index for uniquely showing NetworkInterface which IP address is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.2
The command that returns all setup about TCP/IP to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetTcpipAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.3
IP address of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  IpAddress  

mltNetTcpipSubnet 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.4
Subnet mask of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  IpAddress  

mltNetTcpipGateway 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.5
DefaultGateway of NetworkInterface. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  IpAddress  

mltNetTcpipUseBootProtocol 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.6
Specifies the IP address acquisition method of NetworkInterface. The value taken by default depends on the implementation of a model. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  INTEGER neverUse(0), useWhenNoAddress(1), useEveryTime(2)  

mltNetTcpipBootProtocolEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.7
Bitmap for specifying BootProtocol used in order to determine the IP address of NetworkInterface. The value that should have by Default depends on the implementation of a model. An integer bitmap value specifying bootProtocols. Each bit in the integer is defined as follows. bit Value Type --- ----- --------- 0 1 Arp & Ping 1 2 RARP 2 4 BootP 3 8 DHCP 4 16 AutoIP If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  INTEGER  

mltNetTcpipAddressServer 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.8
IP address of Server which offered IP address when IP address was acquired by bootProtocol. When it is manually inputted or Address in NVRAM is used, '0.0.0.0' shall be inputted for this value. This value shall be held even if turning a power supply off.
OBJECT-TYPE    
  IpAddress  

mltNetTcpipRawPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.9
Port number for RAW socket printing. Default shall be '9100'. In addition, two or more RAW Port printings shall not be supported. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  INTEGER  

mltNetTcpipSupportService 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.10
In NetworkInterface, shows the service supported on TCP/IP by Bitmap. An integer bitmap value specifying TCP/IP support service information. Each bit in the integer is defined as follows. bit Value Service --- ----- --------- 0 1 Reserved 1 2 Reserved 2 4 LPD 3 8 Reserved for LPR 4 16 telnet 5 32 Reserved for telnet client 6 64 ftp server 7 128 ftp client 8 256 http server 9 512 Reserved for http client 10 1024 Reserved for POP3 server 11 2048 POP3 client 12 4096 Reserved for SMTP server 13 8132 SMTP client 14 16364 ipp 15 32768 Reserved 16 65536 Reserved 17 131072 slp 18 262144 Reserved for IMAP server 19 524288 IMAP client 20 1048576 Reserved 21 2097152 Reserved for UPnP
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsSupport 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.11
Sets up the availability of use of DNS. The following value shall be used. When DNS is not being supported, always takes 0. When supporting, Default shall be noUse(2). If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  INTEGER notSupported(0), use(1), noUse(2)  

mltNetTcpipDnsHostName 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.12
The host name of NetworkInterface used by DNS. Default in the case of supporting DNS is Null (size =0). When DNS is not being supported, implement '-' (hyphen) and shall be RO. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetTcpipDnsDomainName 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.1.1.13
Domain name to which NetworkInterface used by DNS belongs. Default in the case of supporting DNS is Null (size =0). When DNS is not being supported, implement '-' (hyphen) and shall be RO. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetTcpipDnsTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2
The table for showing DNS Server.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetTcpipDnsEntry

mltNetTcpipDnsEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1
OBJECT-TYPE    
  MltNetTcpipDnsEntry  

mltNetTcpipDnsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.1
The index for uniquely showing NetworkInterface to which IP address is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsServerIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.2
The index for uniquely showing each DNS Server. It shall have at least one or more Indexes as Default. The number of Indexes depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetTcpipDnsServerAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.1.2.1.3
IP address of DNS Server. If this setting can not be set from Network access, a device should implement this value with RO access.
OBJECT-TYPE    
  IpAddress  

mltNetLpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.2
OBJECT IDENTIFIER    

mltNetLpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1
The table for showing the general information of lpd.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetLpdGeneralEntry

mltNetLpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1
OBJECT-TYPE    
  MltNetLpdGeneralEntry  

mltNetLpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.1
The index for uniquely specifying NetworkInterface to which lpd is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetLpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.2
Sets up Enable/Disable of service of lpd.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetLpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.1.1.3
Specifies Port number which lpd uses. Default is 515.
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2
The table for showing the information of Queue of lpd.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetLpdQueueEntry

mltNetLpdQueueEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1
OBJECT-TYPE    
  MltNetLpdQueueEntry  

mltNetLpdQueueIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.1
The index for uniquely specifying NetworkInterface to which each Queue is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.2
The index for uniquely showing Queue set up for every NetworkInterface. The number of Indexes depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueName 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.3
The name of Queue used at the time of printing by lpd. The value of Default depends on a model. Default shall be '-' (hyphen) when printing function has no relation to the name of Queue.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetLpdQueueDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.4
It recommends describing the information which serves as help when a user performs a setup for lpr printing.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetLpdQueueFilter 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.5
Selects Filter function set as Queue by Bitmap. When there is no Filter function in Queue, shall always be 0. Each bit in the integer is defined as follows. bit Value Filter --- ----- --------- 0 1 FF (Form Feed) 1 2 LF (Line Feed) 2 4 CR (Carriage Return) 3 8 PS (Add PostScript Header) 4 16 reserved 5 32 rejectPS 6 64 rejectPCL 7 128 rejectASCIIt
OBJECT-TYPE    
  INTEGER  

mltNetLpdQueueBanner 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.6
A setup of BannerPage set in Queue.
OBJECT-TYPE    
  INTEGER noBanner(0), ascii(1), pcl(2), ps(3)  

mltNetLpdQueueEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.2.2.1.7
Sets up Enable/Disable of each Queue.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetFtpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.6
OBJECT IDENTIFIER    

mltNetFtpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1
The table for showing the general information of FTP Server.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetFtpdGeneralEntry

mltNetFtpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1
OBJECT-TYPE    
  MltNetFtpdGeneralEntry  

mltNetFtpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.1
The index for uniquely specifying NetworkInterface to which FTP server is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetFtpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.2
Sets up Enable/Disable of service of FTP.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetFtpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.1.1.3
Specifies Port number which FTP Server uses. Default is 21.
OBJECT-TYPE    
  INTEGER  

mltNetFtpdConfigTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2
The table for showing the User information connectable to FTPServer.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetFtpdConfigEntry

mltNetFtpdConfigEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1
OBJECT-TYPE    
  MltNetFtpdConfigEntry  

mltNetFtpdConfigIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.1
The Index for uniquely specifying NetworkInterface to which each User considers as an object. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetFtpdUserIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.2
The index for uniquely showing the User. The number of Indexes depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetFtpdUser 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.3
Login user name of FTP Server.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetFtpdUserPassWd 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.4
Password of FTP Server. When it is gotten, applying scramble to value is not accepted. About security, support by the management tool side.
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

mltNetFtpdCapability 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.5
Shows the function permitted to each user on FTP Server by Bitmap. An integer bitmap value specifying FTP function information. Each bit in the integer is defined as follows. bit Value Filter --- ----- --------- 0 1 putting job & No Filter 1 2 putting job & CR-LF invert 2 4 get (status or job or Driver) 3 8 put NIC Firmware 4 16 put Printer Font 5 32 reserved
OBJECT-TYPE    
  INTEGER  

mltNetFtpdDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.6.2.1.6
Explanation etc. of the function set to each user is indicated.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetHttpd 1.3.6.1.4.1.2590.1.1.2.1.5.7.8
OBJECT IDENTIFIER    

mltNetHttpdGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1
The table for showing the general information about HTTP Server.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetHttpdGeneralEntry

mltNetHttpdGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1
OBJECT-TYPE    
  MltNetHttpdGeneralEntry  

mltNetHttpdIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.1
Index for uniquely showing NetworkInterface to which HTTP Server is set up. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetHttpdEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.2
Sets up Enable/Disable of service of HTTP Server.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetHttpdPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.3
The port number which HTTP Server uses. Default is 80.
OBJECT-TYPE    
  INTEGER  

mltNetHttpdDescr 1.3.6.1.4.1.2590.1.1.2.1.5.7.8.1.1.4
Indicates the information, such as a version of HTTP Server.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSmtpClient 1.3.6.1.4.1.2590.1.1.2.1.5.7.13
OBJECT IDENTIFIER    

mltNetSmtpGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1
The table for showing the general information of SMTP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmtpGeneralEntry

mltNetSmtpGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1
OBJECT-TYPE    
  MltNetSmtpGeneralEntry  

mltNetSmtpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.1
The index for uniquely specifying NetworkInterface to which SMTP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSmtpEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.2
Sets up Enable/Disable of service of SMTP.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetSmtpServerAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.3
Shows the IP address of SMTP Server. Considering about specification by Domain name, it is made into DisplayString. In the case of specifying by the IP address, it shall be handled as a character string of maximum 15 characters of 'xxx.xxx.xxx.xxx'. Whether to accept a setup by Domain name is dependent on an implementation of a model.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetSmtpPort 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.1.1.4
Specifies Port number which SMTP uses. Default is 25.
OBJECT-TYPE    
  INTEGER  

mltNetSmtpAccountTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2
The table for showing Account information of SMTP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmtpAccountEntry

mltNetSmtpAccountEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1
OBJECT-TYPE    
  MltNetSmtpAccountEntry  

mltNetSmtpAccountIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.1
The index for uniquely specifying NetworkInterface to which each From setup makes into the object. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSmtpAccountIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.2
The index for uniquely showing e-mail From address setup. Although the number of index depends on an implementation, index of the number of functions in which EP-NET and Scan function etc. are supporting needs to be prepared in Default.
OBJECT-TYPE    
  INTEGER  

mltNetSmtpFromAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.3
The address of From Field used by SMTP.
OBJECT-TYPE    
  DisplayString SIZE(0..129)  

mltNetSmtpReplyAddress 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.4
The address of RepryTo used by SMTP.
OBJECT-TYPE    
  DisplayString SIZE(0..129)  

mltNetSmtpConnTimeout 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.5
Timeout setup in SMTP. A unit is second. It shall be possible to set the number between 30-300. Default is 60 (seconds).
OBJECT-TYPE    
  INTEGER  

mltNetSmtpPurpose 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.6
Displays the use of From setup of SMTP.
OBJECT-TYPE    
  INTEGER other(0), epNet(1), scanFunction(2)  

mltNetSmtpDescription 1.3.6.1.4.1.2590.1.1.2.1.5.7.13.2.1.7
Description of each From setup. Default is dependent on an implementation.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetIpp 1.3.6.1.4.1.2590.1.1.2.1.5.7.14
OBJECT IDENTIFIER    

mltNetIppGeneral 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1
OBJECT IDENTIFIER    

mltNetIppGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1
The table for showing the general information of IPP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppGeneralEntry

mltNetIppGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1
OBJECT-TYPE    
  MltNetIppGeneralEntry  

mltNetIppGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetIppServiceEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.2
Sets up Enable/Disable of service of IPP
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetIppDefaultPortIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.1.1.3
mltNetIppPortIndex which shows Default Port number used by IPP.
OBJECT-TYPE    
  INTEGER  

mltNetIppPortTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2
The table for showing Port information of IPP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppPortEntry

mltNetIppPortEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1
OBJECT-TYPE    
  MltNetIppPortEntry  

mltNetIppPortIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of Index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetIppPortIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.2
The index for uniquely showing Port.
OBJECT-TYPE    
  INTEGER  

mltNetIppPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.1.2.1.3
Port number. '631' is supported at least.
OBJECT-TYPE    
  INTEGER  

mltNetIppPrtDescrAttribute 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2
OBJECT IDENTIFIER    

mltNetIppPrtDescGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1
The table for showing the general information about Printer Description Attribute of IPP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppPrtDescGeneralEntry

mltNetIppPrtDescGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1
OBJECT-TYPE    
  MltNetIppPrtDescGeneralEntry  

mltIppPrtDescGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppPrtName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.2
'printer-name' attribute is shown.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppPrtMoreInfo 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.3
'printer-more-info' attribute is shown.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppPrtState 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.4
'printer-state' attribute is shown.
OBJECT-TYPE    
  INTEGER idle(3), processing(4), stopped(5)  

mltIppCharSetConfiguredIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.5
Index which shows 'charset-configured.'
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLanguageConfiguredIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.6
'natural-language-configured' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatDefaultIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.7
'document-format-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppPrinterIsAcceptingJobs 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.8
'printer-is-accepting-jobs' attribute is shown.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppQueuedJobCount 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.9
'queued-job-count' attribute is shown.
OBJECT-TYPE    
  Counter  

mltIppColorSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.10
'color-supported' attribute is shown.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppPdlOverrideSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.11
'pdl-override-supported' attribute is shown.
OBJECT-TYPE    
  INTEGER attempted(3), notAttempted(4)  

mltIppPrinterUpTime 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.12
'printer-up-time' attribute is shown.
OBJECT-TYPE    
  TimeTicks  

mltIppPrtLocation 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.13
'printer-location' attribute is shown.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppPrinterCurrentTime 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.1.1.21
'printer-current-up-time' attribute is shown.
OBJECT-TYPE    
  DateAndTime  

mltIppUriSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2
The table for showing 'printer-uri-authentication-supported' and 'printer-uri-security-supported' to 'printer-uri-supported' attribute and each 'printer-uri'.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppUriSupportedEntry

mltIppUriSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1
OBJECT-TYPE    
  MltIppUriSupportedEntry  

mltIppUriIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppUriIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.2
Index for uniquely showing 'printer-uri'.
OBJECT-TYPE    
  INTEGER  

mltIppUri 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.3
'printer-uri' to support is shown.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppUriSecurity 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.4
'printer-uri-security' to 'printer-uri' to support is shown.
OBJECT-TYPE    
  INTEGER none(3), ssl3(4), tls(5)  

mltIppUriAuthentication 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.2.1.5
'printer-uri-authentication' to 'printer-uri' to support is shown. This item is an IPP Ver1.1 support item. In implementation of IPP Ver1.0, it is not necessary to implement this item.
OBJECT-TYPE    
  INTEGER none(3), requestingUserName(4), basic(5), digest(6), certificate(7)  

mltIppPrtStateReasonsTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3
The table which shows 'printer-state-reasons' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppPrtStateReasonsEntry

mltIppPrtStateReasonsEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1
OBJECT-TYPE    
  MltIppPrtStateReasonsEntry  

mltIppPrtStateReasonIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppPrtStateReasonIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.2
Index for uniquely showing 'printer-state-reasons'.
OBJECT-TYPE    
  INTEGER  

mltIppPrinterStateReason 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.3
'printer-state-reasons' attribute is shown. mltIppPrtStateReasonSuffix shows suffix of '-report', '-warning', and '-error'
OBJECT-TYPE    
  INTEGER other(2), none(3), mediaNeeded(4), mediaJam(5), movingToPaused(6), paused(7), shutDown(8), connectingToDevice(9), timedOut(10), stopping(11), stoppedPartly(12), tonerLow(13), tonerEmpty(14), spoolAreaFull(15), coverOpen(16), interlockOpen(17), doorOpen(18), inputTrayMissing(19), mediaLow(20), mediaEmpty(21), outputTrayMissing(22), outputAreaAlmostFull(23), outputAreaFull(24), markerSupplyLow(25), markerSupplyEmpty(26), markerWasteAlmostFull(27), markerWasteFull(28), fuserOverTemp(29), fuserUnderTemp(30), opcNearEndOfLife(31), opcLifeOver(32), developerLow(33), developerEmpty(34), interpreterResourceUnavailable(35)  

mltIppPrtStateReasonSuffix 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.3.1.4
Three suffixes ('-report', '-warning', and '-error') of 'printer-state-reasons' attribute are shown.
OBJECT-TYPE    
  INTEGER report(3), warning(4), error(5)  

mltIppVersionsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4
Table which shows 'ipp-versions-supported.' This item is an IPP Ver1.1 support item. In implementation of IPP Ver1.0, it is not necessary to implement this item.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppVersionsSupportedEntry

mltIppVersionsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1
OBJECT-TYPE    
  MltIppVersionsSupportedEntry  

mltIppVersionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppVersionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.2
Index for uniquely showing 'ipp-version'.
OBJECT-TYPE    
  INTEGER  

mltIppVersionType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.4.1.3
'ipp-version' to support is shown
OBJECT-TYPE    
  INTEGER ipp10(3), ipp11(4)  

mltIppOperationSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5
Table which has 'operation-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppOperationSupportedEntry

mltIppOperationSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1
OBJECT-TYPE    
  MltIppOperationSupportedEntry  

mltIppOperationIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppOperationIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.2
Index which shows 'operation' to support.
OBJECT-TYPE    
  INTEGER  

mltIppOperationType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.3
Type of 'operation' is shown
OBJECT-TYPE    
  INTEGER printJob(2), printURI(3), validateJob(4), createJob(5), sendDocument(6), sendURI(7), cancelJob(8), getJobAttributes(9), getJobs(10), getPrinterAttributes(11), holdJobs(12), releaseJob(13), restartJob(14), pausePrinter(16), resumePrinter(17), purgeJobs(18)  

mltIppOperationEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.5.1.4
This shows Opeartor's Enable/Disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppCharSetSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6
Table which shows 'charset-supported.'
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppCharSetSupportedEntry

mltIppCharSetSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1
OBJECT-TYPE    
  MltIppCharSetSupportedEntry  

mltIppCharSetIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppCharSetIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.2
Index for uniquely showing 'charset'.
OBJECT-TYPE    
  INTEGER  

mltIppCharSetName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.3
A parameter should follow regulation of IANA of the following. http://www.iana.org/assignments/character-set
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppCharSetCode 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.6.1.4
The code of 'charset' to support A parameter should follow regulation of IANA of the following. http://www.iana.org/assignments/character-set
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLanguageSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7
Table which shows 'generated-natural-language-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppNaturalLanguageSupportedEntry

mltIppNaturalLanguageSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1
OBJECT-TYPE    
  MltIppNaturalLanguageSupportedEntry  

mltIppNaturalLangIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLangIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.2
Index for uniquely showing 'natural-language'.
OBJECT-TYPE    
  INTEGER  

mltIppNaturalLangName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.7.1.3
The name of 'natural-language' to support.
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppDocFormatSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8
Table which shows 'document-format-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppDocFormatSupportedEntry

mltIppDocFormatSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1
OBJECT-TYPE    
  MltIppDocFormatSupportedEntry  

mltIppDocFormatIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.2
The index for uniquely showing 'document-format'.
OBJECT-TYPE    
  INTEGER  

mltIppDocFormatName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.8.1.3
The name of 'document-format' to support is shown
OBJECT-TYPE    
  DisplayString SIZE(0..127)  

mltIppCompressionSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10
Table which shows 'compression-supported.'
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppCompressionSupportedEntry

mltIppCompressionSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1
OBJECT-TYPE    
  MltIppCompressionSupportedEntry  

mltIppCompressionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.1
Index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppCompressionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.2
Index for uniquely showing 'compression'.
OBJECT-TYPE    
  INTEGER  

mltIppCompressionType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.2.10.1.3
'compression' currently supported is shown.
OBJECT-TYPE    
  INTEGER none(3), deflate(4), gzip(5), compress(6)  

mltNetIppJobTemplateAttribute 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3
OBJECT IDENTIFIER    

mltNetIppJobTemplateGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1
The table for showing the general information about Job Template Attribute of IPP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetIppJobTemplateGeneralEntry

mltNetIppJobTemplateGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1
OBJECT-TYPE    
  MltNetIppJobTemplateGeneralEntry  

mltIppJobTemplateGeneralIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppJobPriorityDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.2
'job-priority-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppJobPrioritySupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.3
'job-priority-supported' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.4
'job-hold-until-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.5
'ipp-job-sheets-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppCopiesDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.6
'copies-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppCopiesMaxSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.7
'copies-supported' attribute is shown. Since MIN value is surely 1, only MAX is shown.
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.8
'finishings-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppPageRangesSupported 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.9
'page-ranges-supported' attribute is shown.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltIppSidesDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.10
'sides-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.11
'number-up-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.12
'orientation-requested-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppMediaDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.13
'media-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppPrinterResolutionDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.14
'printer-resolution-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppPrintQualityDefault 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.1.1.15
'print-quality-default' attribute is shown.
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2
Table which shows 'job-hold-until-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppJobHoldUntilSupportedEntry

mltIppJobHoldUntilSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1
OBJECT-TYPE    
  MltIppJobHoldUntilSupportedEntry  

mltIppJobHoldUntilIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.2
Index for uniquely showing 'job-hold-until'.
OBJECT-TYPE    
  INTEGER  

mltIppJobHoldUntilType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.2.1.3
Type of 'job-hold-until' to support.
OBJECT-TYPE    
  INTEGER noHold(3), indefinite(4), dayTime(5), evening(6), night(7), weekend(8), secondShift(9), thirdShift(10)  

mltIppJobSheetsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3
Table which shows 'ipp-job-sheets-supported'.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppJobSheetsSupportedEntry

mltIppJobSheetsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1
OBJECT-TYPE    
  MltIppJobSheetsSupportedEntry  

mltIppJobSheetsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.2
Index for uniquely showing 'job-sheets'.
OBJECT-TYPE    
  INTEGER  

mltIppJobSheetsType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.3.1.3
Type of 'job-sheets' to support is shown.
OBJECT-TYPE    
  INTEGER none(3), standard(4)  

mltIppFinishingsSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4
Table which shows 'finishings-supported'.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppFinishingsSupportedEntry

mltIppFinishingsSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1
OBJECT-TYPE    
  MltIppFinishingsSupportedEntry  

mltIppFinishingsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.2
Index for uniquely showing 'finishings'.
OBJECT-TYPE    
  INTEGER  

mltIppFinishingsType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.4.1.3
Type of 'finishings' to support.
OBJECT-TYPE    
  INTEGER none(3), staple(4), punch(5), cover(6), bind(7), saddle-stitch(8), edge-stitch(9), staple-top-left(20), staple-bottom-left(21), staple-top-right(22), staple-bottom-right(23), edge-stitch-left(24), edge-stitch-top(25), edge-stitch-right(26), edge-stitch-bottom(27), staple-dual-left(28), staple-dual-top(29), staple-dual-right(30), staple-dual-bottom(31)  

mltIppSidesSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5
Table which shows 'sides-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppSidesSupportedEntry

mltIppSidesSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1
OBJECT-TYPE    
  MltIppSidesSupportedEntry  

mltIppSidesIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppSidesIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.2
Index for uniquely showing 'sides'.
OBJECT-TYPE    
  INTEGER  

mltIppSidesType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.5.1.3
Type of 'sides' to support
OBJECT-TYPE    
  INTEGER one-sided(3), two-sided-long-edge(4), two-sided-short-edge(5)  

mltIppNumberUpSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6
Table which shows 'number-up-supported'.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppNumberUpSupportedEntry

mltIppNumberUpSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1
OBJECT-TYPE    
  MltIppNumberUpSupportedEntry  

mltIppNumberUpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.2
Index for uniquely showing 'number-up'.
OBJECT-TYPE    
  INTEGER  

mltIppNumberUpType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.6.1.3
The 'number-up' value to support is shown.
OBJECT-TYPE    
  INTEGER num1Up(1), num2Up(2), num4Up(3), num9Up(4), num16Up(5)  

mltIppOrientationRequestedSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7
'orientation-requested-supported' attribute is shown.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppOrientationRequestedSupportedEntry

mltIppOrientationRequestedSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1
OBJECT-TYPE    
  MltIppOrientationRequestedSupportedEntry  

mltIppOrientationRequestedIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.2
Index for uniquely showing 'orientation-requested'.
OBJECT-TYPE    
  INTEGER  

mltIppOrientationRequestedType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.7.1.3
Type of 'orientation-requested' to support.
OBJECT-TYPE    
  INTEGER portrait(3), landscape(4), reverse-landscape(5), reverse-portrait(6)  

mltIppMediaSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8
Table which shows 'media-supported' attribute.
OBJECT-TYPE    
  SEQUENCE OF  
    MltIppMediaSupportedEntry

mltIppMediaSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1
OBJECT-TYPE    
  MltIppMediaSupportedEntry  

mltIppMediaIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltIppMediaIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.2
Index for uniquely showing 'media'.
OBJECT-TYPE    
  INTEGER  

mltIppMediaName 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.3
The name of 'media' currently supported. Refer to Bergman, R, 'Media Size Standardized Names', PWG Draft Standard D0.5, March 26, 2001.
OBJECT-TYPE    
  OCTET STRING SIZE(0..63)  

mltIppMediaType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.4
mediatype of 'media' currently supported.
OBJECT-TYPE    
  OCTET STRING SIZE(0..63)  

mltIppMediaColor 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.5
The color of 'media' currently supported.
OBJECT-TYPE    
  OCTET STRING SIZE(0..63)  

mltIppMediaInputTray 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.8.1.6
Tray to which 'media' currently supported is set.
OBJECT-TYPE    
  OCTET STRING SIZE(0..63)  

mltPrinterResolutionSupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9
Table which shows 'printer-resolution-supported'.
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrinterResolutionSupportedEntry

mltPrinterResolutionSupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1
OBJECT-TYPE    
  MltPrinterResolutionSupportedEntry  

mltPrinterResolutionIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltPrinterResolutionIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.2
Index for uniquely showing 'printer-resolution'.
OBJECT-TYPE    
  INTEGER  

mltPrinterResolutionFeedDir 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.3
The value of Feed direction of 'printer-resolution' to support.
OBJECT-TYPE    
  Integer32  

mltPrinterResolutionXFeedDir 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.4
The value of XFeed direction of 'printer-resolution' to support.
OBJECT-TYPE    
  Integer32  

mltPrinterResolutionUnit 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.9.1.5
Unit of 'printer-resolution' to support .
OBJECT-TYPE    
  INTEGER other(1), tenThousandthsOfInches(3), micrometers(4)  

mltPrintQualitySupportedTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10
Table which shows 'print-quality-supported' attribute
OBJECT-TYPE    
  SEQUENCE OF  
    MltPrintQualitySupportedEntry

mltPrintQualitySupportedEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1
OBJECT-TYPE    
  MltPrintQualitySupportedEntry  

mltPrintQualityIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.1
The index for uniquely specifying NetworkInterface to which IPP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltPrintQualityIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.2
Index for uniquely showing 'print-quality'.
OBJECT-TYPE    
  INTEGER  

mltPrintQualityType 1.3.6.1.4.1.2590.1.1.2.1.5.7.14.3.10.1.3
Type of 'print-quality' to support.
OBJECT-TYPE    
  INTEGER draft(3), normal(4), high(5)  

mltNetSlp 1.3.6.1.4.1.2590.1.1.2.1.5.7.17
OBJECT IDENTIFIER    

mltNetSlpGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1
Table for showing the general information of SLP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSlpGeneralEntry

mltNetSlpGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1
OBJECT-TYPE    
  MltNetSlpGeneralEntry  

mltNetSlpIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.1
The index for uniquely specifying NetworkInterface to which SLP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSlpEnable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.2
Enable/Disable of service of SLP is set up.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mltNetSlpPortNumber 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.3
Port number of SLP is shown. Default is 427.
OBJECT-TYPE    
  INTEGER  

mltNetSlpMTU 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.4
MTU value of LP gas is shown. Default shall be 1400.
OBJECT-TYPE    
  INTEGER  

mltNetSlpTTL 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.5
TTL value of SLP is shown. Default shall be 255.
OBJECT-TYPE    
  INTEGER  

mltNetSlpBroadcastSupport 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.1.1.6
Support of multicasting and broadcasting is shown.
OBJECT-TYPE    
  INTEGER broadcastOnly(1), multicastOnly(2), both(3)  

mltNetSlpConfigTable 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2
The table for showing the setup information of SLP.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSlpConfigEntry

mltNetSlpConfigEntry 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1
OBJECT-TYPE    
  MltNetSlpConfigEntry  

mltNetSlpConfigIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.1
The index for uniquely specifying NetworkInterface to which SLP is set. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSlpIndex 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.2
Index for showing a specific entry. Default is 1.
OBJECT-TYPE    
  INTEGER  

mltNetSlpService 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.3
The character string which shows the service registered into DA. Example: 'service:printer:help'
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSlpScope 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.4
The character string which shows the scope of SLP. Default character string is 'default'.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSlpLifetime 1.3.6.1.4.1.2590.1.1.2.1.5.7.17.2.1.5
The value which shows LifeTime of a registration. A unit is second. Default is 10800 (3 hours).
OBJECT-TYPE    
  INTEGER  

mltNetNetWare 1.3.6.1.4.1.2590.1.1.2.1.5.8
OBJECT IDENTIFIER    

mltNetNwGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.1
Table with the basic information of NetWare relation which NetworkInterface has
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwGeneralEntry

mltNetNwGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1
OBJECT-TYPE    
  MltNetNwGeneralEntry  

mltNetNwIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetNwDefault 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.2
The command which restores all setup about NetWare to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetNwFrameTypeConfig 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.3
A setup of FrameType used by NetWare (IPX). It is set by using Bitmap of the following. 1 (Auto-Sense) is recommended for the Default. Although Auto-Sense and other value do not exist together, about Binding two or more FrameTypes simultaneously, it is dependent on the implementation of a model. Bit Value FrameType ---- ---- ---------- 0 1 Reserved 1 2 802.3 2 4 EthernetII 3 8 802.3-SNAP 4 16 802.2 (4) 5 32 Reserved 6 64 802.5-TokenRing 7 128 TokenRing-SNAP
OBJECT-TYPE    
  INTEGER  

mltNetNwPrintMode 1.3.6.1.4.1.2590.1.1.2.1.5.8.1.1.4
The mode of NetworkInterface used by NetWare is set up. Default shall be pServerMode(1). When not supporting NPrinter, it shall be the implementation of RO.
OBJECT-TYPE    
  INTEGER pServerMode(1), nPrinterMode(2)  

mltNetNwFrameTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.2
The information of FrameType which is working in NetWare is shown.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwFrameEntry

mltNetNwFrameEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1
OBJECT-TYPE    
  MltNetNwFrameEntry  

mltNetNwFrameIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetNwFrameIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.2
Index for showing FrameType which is operating by NetworkInterface.
OBJECT-TYPE    
  INTEGER  

mltNetNwFrameType 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.3
FrameType is shown.
OBJECT-TYPE    
  INTEGER ethernet8023(1), ethernetII(2), ethernetSnap(3), ethernet8022(4), tokenRing8025(6), tokenRingSnap(7)  

mltNetNwNetworkNumber 1.3.6.1.4.1.2590.1.1.2.1.5.8.2.1.4
Network number which each FrameType is using is displayed. The notation of a number is indicated by Hexadecimal numbers.
OBJECT-TYPE    
  OCTET STRING SIZE(0..8)  

mltNetNwPserverTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.3
The table for showing the setup of PrintServer.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwPserverEntry

mltNetNwPserverEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1
OBJECT-TYPE    
  MltNetNwPserverEntry  

mltNetNwPsIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetNwPsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.2
Index for uniquely showing PrintServer. The number of indexes depends on an implementation. The number of indexes which can be implemented and the number of defaults depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetNwPsName 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.3
The name of PrintServer. Default is dependent on an implementation.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetNwPsPasswd 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.4
Password of PrintServer. Default is Null. When it is gotten, applying scramble to value is not accepted. About security, support by the management tool side.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetNwPsMode 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.5
The mode in which PrintServer supports is shown.
OBJECT-TYPE    
  INTEGER both(0), binderyMode(1), ndsMode(2)  

mltNetNwPsPrefFServer 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.6
Value of Preferred FileServer used in Bindery mode. It shall be NullString when set only to NDS mode. In the system which does not set up PreferredFileServer, implement '-' (hyphen) and shall be RO.
OBJECT-TYPE    
  DisplayString SIZE(0..47)  

mltNetNwPsPrefTree 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.7
Value of Preferred Tree used in NDS mode. It shall be NullString when set only to Bindery mode. In the system which does not set up PreferredTree, implement 'N/A' and shall be RO.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetNwPsPrefContext 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.8
Value of Preferred Context used in NDS mode. It shall be NullString when set only to Bindery mode. In the system which does not set up PreferredContext, implement 'N/A' and shall be RO.
OBJECT-TYPE    
  DisplayString SIZE(0..191)  

mltNetNwPsPollingRate 1.3.6.1.4.1.2590.1.1.2.1.5.8.3.1.9
The interval at which PrinteServer scans Queue. Unit is second. Range which can be set up shall be 1 - 65535. Default is 1 (second).
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.4
Table which shows the information of Queue which NetworkInterface has managed.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwQueueEntry

mltNetNwQueueEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1
OBJECT-TYPE    
  MltNetNwQueueEntry  

mltNetNwQueueIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.1
The index for uniquely showing Queue.
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueName 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.2
The name of Queue.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetNwQueueRefIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.3
NetworkInterface which is managing Queue is shown. Use the value of mltNetNwPsIfIndex.
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueRefPsIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.4
PrintServer which is managing Queue is shown. Use the value of mltNetNwPsIndex.
OBJECT-TYPE    
  INTEGER  

mltNetNwQueueStatus 1.3.6.1.4.1.2590.1.1.2.1.5.8.4.1.5
The state of Queue is shown.
OBJECT-TYPE    
  INTEGER unknown(0), available(1), allocated(2), inUse(3)  

mltNetNwNPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.8.5
Table which shows the information of NPrinter which NetworkInterface is managing. In the system without Nprinter function, it is not necessary to implement this table.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetNwNPrinterEntry

mltNetNwNPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1
OBJECT-TYPE    
  MltNetNwNPrinterEntry  

mltNetNwNPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetNwNPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.2
Index for uniquely showing Nprinter.
OBJECT-TYPE    
  INTEGER  

mltNetNwNPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.3
The name of Nprinter.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltNetNwNPrinterNumber 1.3.6.1.4.1.2590.1.1.2.1.5.8.5.1.4
Printer number of NPrinter. Default shall be 1.
OBJECT-TYPE    
  INTEGER  

mltNetAppleTalk 1.3.6.1.4.1.2590.1.1.2.1.5.9
OBJECT IDENTIFIER    

mltNetAppleTalkGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.9.1
Table with the basic information of AppleTalk relation which NetworkInterface has.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetAppleTalkGeneralEntry

mltNetAppleTalkGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1
OBJECT-TYPE    
  MltNetAppleTalkGeneralEntry  

mltNetAtIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetAtDefault 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.2
The command which restores all setup about AppleTalk to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetAtNetNumber 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.3
NetworkNumber in Network of AppleTalk. Display the value acquired at the time of Apple Talk starting. When it is unknown, shall be -2 (unknown).
OBJECT-TYPE    
  INTEGER  

mltNetAtNodeNumber 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.4
Node Number in Network of AppleTalk. Display the value acquired at the time of Apple Talk starting. When it is unknown, shall be -2 (unknown).
OBJECT-TYPE    
  INTEGER  

mltNetAtDesiredZone 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.5
Setting value of Zone name in Apple Talk. Default shall be '*'.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetAtCurrentZone 1.3.6.1.4.1.2590.1.1.2.1.5.9.1.1.6
Zone name to which device is operating. In environment of operation, it may differ from the above-mentioned value.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetAtPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.9.2
The table for showing the setup of AppleTalkPrinter.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetAtPrinterEntry

mltNetAtPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1
OBJECT-TYPE    
  MltNetAtPrinterEntry  

mltNetAtPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetAtPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.2
The index for uniquely showing AppleTalkPrinter. The number of indexed depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetAtPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.3
The name of AppleTalkPrinter. When performing the operation, the name in an actual operation environment should be shown.
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

mltNetAtPrinterType 1.3.6.1.4.1.2590.1.1.2.1.5.9.2.1.4
Type of AppleTalk Printer. Default is 'LaserWriter'.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSmb 1.3.6.1.4.1.2590.1.1.2.1.5.10
OBJECT IDENTIFIER    

mltNetSmbGeneralTable 1.3.6.1.4.1.2590.1.1.2.1.5.10.1
The table with the basic information of SMB relation which NetworkInterface has.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmbGeneralEntry

mltNetSmbGeneralEntry 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1
OBJECT-TYPE    
  MltNetSmbGeneralEntry  

mltNetSmbIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSmbDefault 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.2
The command which restores all setup about SMB to FactoryDefault. When resetToDefault(2) is set, an agent side shall surely return Reply. In principle, when resetToDefault(2) is set, about the timing in which the setup returns to default depends on an implementation and it does not define in MIB.
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1), resetToDefault(2)  

mltNetSmbWorkGroupName 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.3
WorkGroup name in Windows Network. Default shall be 'WORKGROUP'. Only the implementation of capital letters is accepted about this item.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSmbHostName 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.4
Host name in Windows Network. Default is dependent on an implementation. Only the implementation of capital letters is accepted about this item
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSmbWinsSupport 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.5
Sets up the availability of use of WINS. Default is disable(2).
OBJECT-TYPE    
  INTEGER notSupported(0), enable(1), disable(2)  

mltNetSmbWinsPrimaryServer 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.6
Sets up PrimaryServer of Wins. Default is 0.0.0.0
OBJECT-TYPE    
  IpAddress  

mltNetSmbWinsSecondaryServer 1.3.6.1.4.1.2590.1.1.2.1.5.10.1.1.7
Sets up Secondary Server of Wins. Default is 0.0.0.0.
OBJECT-TYPE    
  IpAddress  

mltNetSmbPrinterTable 1.3.6.1.4.1.2590.1.1.2.1.5.10.2
The table which has the information of Printer relation in SMB.
OBJECT-TYPE    
  SEQUENCE OF  
    MltNetSmbPrinterEntry

mltNetSmbPrinterEntry 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1
OBJECT-TYPE    
  MltNetSmbPrinterEntry  

mltNetSmbPrinterIfIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.1
The index for uniquely showing NetworkInterface. The value of index shall be the same value with mltNetGeneralIndex (ifIndex).
OBJECT-TYPE    
  INTEGER  

mltNetSmbPrinterIndex 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.2
Index for uniquely showing Printer in SMB. The number of indexes depends on an implementation.
OBJECT-TYPE    
  INTEGER  

mltNetSmbPrinterName 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.3
Printer name in SMB. Default is dependent on the implementation of a model. About the availability of Printer name change shall also be dependent on an implementation.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltNetSmbPrinterDescr 1.3.6.1.4.1.2590.1.1.2.1.5.10.2.1.4
Explanation of Printer. About the written contents is dependent on the implementation of a model; however, implementation of NullString is not accepted. At least input the character string which is same as Default Printer name.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltDevice 1.3.6.1.4.1.2590.1.1.3
OBJECT IDENTIFIER    

mltJob 1.3.6.1.4.1.2590.1.1.4
OBJECT IDENTIFIER    

mltJobManagement 1.3.6.1.4.1.2590.1.1.4.1
OBJECT IDENTIFIER    

mltJmMibVersion 1.3.6.1.4.1.2590.1.1.4.1.1
The standardization version of MIB implemented in JobManagement relation. This indicates the version of the Private Job Management MIB that is implemented. There are some mib objects that indicate the Mib Version. (mltSysMibVersion, mltPrtMibVersion, mltScnMibVersion, mltNetMiIbVersion, mltJmMibVersion) But, the each mib version should be same version. Especially, the each major versions must be same. The version information of Standard MIB specification. General form is AA.BC. AA is indicating major revision, and B and C is minor revision. Decimal point is ASCII-coded period.
OBJECT-TYPE    
  DisplayString SIZE(0..7)  

mltJmGeneral 1.3.6.1.4.1.2590.1.1.4.1.2
OBJECT IDENTIFIER    

mltJmGeneralTable 1.3.6.1.4.1.2590.1.1.4.1.2.1
This table indicates the general information about Job Management. This table contains the number of active jobs, oldest/newest jobs, the number of preservation of a history, and so on.
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmGeneralEntry

mltJmGeneralEntry 1.3.6.1.4.1.2590.1.1.4.1.2.1.1
OBJECT-TYPE    
  MltJmGeneralEntry  

mltJmGeneralJobSetIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.1
A unique value for each job set in this MIB. JobSet shows the system of the serial number used for Job management. In managing a serial number to 1 by all the functions of a device according to 'Job management standard specifications', it sets the number of JobSets to 1. In managing a serial number for every functional classification, only the number of functional classifications shall have JobSet.
OBJECT-TYPE    
  INTEGER  

mltJmGeneralNumberOfActiveJobs 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.2
The current number of 'active' jobs in the mltJmJobTable. when the device has no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
OBJECT-TYPE    
  INTEGER  

mltJmGeneralOldestActiveJobIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.3
The mltJmJobIndex of the oldest job that is still in one of the 'active' states. In other words, the index of the 'active' job that has been in the job tables the longest. If there are no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
OBJECT-TYPE    
  INTEGER  

mltJmGeneralNewestActiveJobIndex 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.4
The mltJmJobIndex of the newest job that is in one of the 'active' states. In other words, the index of the 'active' job that has been most recently added to the job tables. If there are no active jobs, this value should be 0. The device that cannot support to count active jobs should implement (-2) as fixed value.
OBJECT-TYPE    
  INTEGER  

mltJmGeneralJobPersistence 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.5
The number holding the information (Index) on Job is specified after an end of Job. About the number which should hold the history information on Job, it shall be dependent on implementation of a model. If a device can not support this, '-2'(Not Support) should be implemented.
OBJECT-TYPE    
  INTEGER  

mltJmGeneralJobSetType 1.3.6.1.4.1.2590.1.1.4.1.2.1.1.6
The type of JobSet.
OBJECT-TYPE    
  INTEGER mfpAll(0), copy(1), print(2), receiveJob(3), sendJob(4), faxReceive(5), faxSend(6), other(7)  

mltJmJob 1.3.6.1.4.1.2590.1.1.4.1.3
OBJECT IDENTIFIER    

mltJmJobTable 1.3.6.1.4.1.2590.1.1.4.1.3.1
The table indicates the detailed information of jobs.
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmJobEntry

mltJmJobEntry 1.3.6.1.4.1.2590.1.1.4.1.3.1.1
OBJECT-TYPE    
  MltJmJobEntry  

mltJmJobJobSetIndex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.1
A unique value for each job set in this MIB. JobSet shows the system of the serial number used for Job management. This index is the same as mltJmGeneralJobSetIndex.
OBJECT-TYPE    
  INTEGER  

mltJmJobIndex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.2
The sequential, monotonously increasing identifier index for the job generated by the device when that device accepted the job. [ This Index shall hold also in power supply On./Off. After attainment is automatically re-started from 1 to maximum.
OBJECT-TYPE    
  INTEGER 1..65535  

mltJmJobFunction 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.3
This value indicates the function of job sender. receiveJob(3) may include FAX and iFAX jobs.
OBJECT-TYPE    
  INTEGER unknown(0), copy(1), print(2), receiveJob(3), sendJob(4), faxReceive(5), faxSend(6), other(7)  

mltJmJobStatus 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.4
This value indicates the status of job.
OBJECT-TYPE    
  INTEGER unknown(0), other(1), cancelRequest(2), puaseRequest(3), restartRequest(4), pending(10), pendingHeld(11), pendingPaused(12), processing(20), sending(21), receiving(22), printing(23), scanning(24), processingStopped(25), completed(30), caution(31), aborted(32), canceled(33)  

mltJmJobReceivedTime 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.6
Registration time of Job. About TimeZone, it is not indispensable. When you cannot perform acquisition of time information, be referred to as Null (Zero-Length).
OBJECT-TYPE    
  DateAndTime  

mltJmJobCompleteTime 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.7
Completion time of Job. About TimeZone, it is not indispensable. When you await and completion time cannot be written by Job etc., be referred to as Null (Zero-Length).
OBJECT-TYPE    
  DateAndTime  

mltJmJobPriority 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.8
It is used when controlling the priority of Job. When device cannot support to change of a priority, this value should be notSupported (0) as RO. When device support to change of a priority, it uses the value of 1 to 5. In this case, implementation as RW is mandatory.
OBJECT-TYPE    
  INTEGER notSupported(0), lowestPriority(1), lowPriority(2), normalPriority(3), highPriority(4), highestPriority(5)  

mltJmJobDivNumber 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.9
The division number of job. 0-999 is used. When the device does not perform division control, this value should be (-2). (-2) means unknown.
OBJECT-TYPE    
  INTEGER  

mltJmJobOwner 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.10
The owner of job. If device cannot detect the name of owner , this value should be '-', of 'unknown'. The implementation of zero-length is not accepted.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltJmJobType 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.11
The type of job. When the job type is not detected, this value should be other(0).
OBJECT-TYPE    
  INTEGER other(0), eMail(11), iFaxSend(12), scanToServer(13), scanToPC(14), scanToHDD(15), twain(16), normalPrint(20), ippPrint(21), securePrint(22), timerPrint(23), printToHDD(24), proofAndPrint(25), reportPrint(29), iFaxReceive(31), normalCopy(40), faxRecieved(51), faxSend(52)  

mltJmJobName 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.12
The name of job. If device cannot detect job name, this value should be '-', of 'unknown'. The implementation of zero-length is not accepted.
OBJECT-TYPE    
  DisplayString SIZE(0..31)  

mltJmJobDocPageNumbers 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.13
The page numbers of job. When device cannot detect page numbers this value should be (-2).
OBJECT-TYPE    
  Integer32  

mltJmJobDocCopyNumbers 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.14
Number of copies of Job. When device cannot detect the number of copies, this value should be (-2).
OBJECT-TYPE    
  Integer32  

mltJmJobPageSize 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.15
The paper/picture size of Job. In case of output job, this value shows output paper size. Incase of scanned job, this value shows the size of picture. In Job of mixed size, the last page should be displayed.
OBJECT-TYPE    
  INTEGER otherPaperSize(0), unknownPaperSize(1), a0(11), a1(12), a2(13), a3(14), a4(15), a5(16), a6(17), b0(21), b1(22), b2(23), b3(24), b4(25), b5(26), b6(27), us12x14(30), ledger(31), us11x15(32), us11x14(33), comp(34), us10x14(35), us9-1by4x14(36), legal(37), us8-1by4x11-3by4(38), letter(39), govLetter(40), quarto(41), executive(42), statement(43), govRegal(44), us3x5(46), us4x6(47), fls(50), fls0(51), fls1(52), fls2(53), fls3(54), hagaki(61), oufuku-Hagaki(62), envelopeB5(63), envelopeCom10(64), envelopeC5(65), envelopeDL(66), envelopeMonarch(67), envelopeC6(68), youkei-0Gou(70), youkei-1Gou(71), youkei-4Gou(74), youkei-6Gou(76), choukei-3Gou(83), choukei-4Gou(84), kakugata-3Gou(93), a3W(114), a4W(115), a5W(116), a6W(117)  

mltJmJobDestination 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.16
The destination of job. If destination is unknown, this value should be '-'.
OBJECT-TYPE    
  DisplayString SIZE(0..63)  

mltJmJobDataSize 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.18
The data size of job. A unit is KByte. In case of printing job, this value should be the size of printing date. In case of send job, this value should be not the size of picture but the size of transefered data. When the device cannot detect data size, this value should be (-2).
OBJECT-TYPE    
  Integer32  

mltJmJobColorMode 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.19
The type of color mode.
OBJECT-TYPE    
  INTEGER other(0), unknown(1), color(2), grayScale(3), blackWhite(4)  

mltJmJobFormat 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.20
The data format of job.
OBJECT-TYPE    
  INTEGER other(0), unknown(1), raw(2), tiff(3), tiff-MH(4), tiff-MR(5), tiff-MMR(6), jpeg(7), pdf(8), pcl(9), postScript(10), gdi(11), linePrinter(12)  

mltJmJobXResolution 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.21
Resolution of the X direction of Job. A unit is dpi.
OBJECT-TYPE    
  INTEGER  

mltJmJobYResolution 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.22
Resolution of the Y direction of Job. A unit is dpi.
OBJECT-TYPE    
  INTEGER  

mltJmJobDuplex 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.23
A duplex setting of job.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

mltJmJobOutputPages 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.25
The page numbers which the output ended in Job. If a device can not recognize this information, '-2'(Not Support) should be implemented.
OBJECT-TYPE    
  Integer32  

mltJmJobOutputSheets 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.26
The sheets numbers which the output ended in Job. If a device can not recognize this information, '-2'(Not Support) should be implemented.
OBJECT-TYPE    
  Integer32  

mltJmJobMediaType 1.3.6.1.4.1.2590.1.1.4.1.3.1.1.27
The media type of job.
OBJECT-TYPE    
  INTEGER otherMediaType(208), unknownMediaType(209), plainPaper(210), plainPaper2side(211), plainPaperRecycled(212), plainPaperExclusive(214), plainPaperColor(216), thick1(222), thick1-2side(223), thick2(224), thick2-2side(225), thick3(226), thick3-2side(227), ohp(230), thin(236), envelope(240), envelope-2side(241), label(242), postCard(244), letterHead(246), tab(248)  

mltJmReport 1.3.6.1.4.1.2590.1.1.4.1.4
OBJECT IDENTIFIER    

mltJmReportTable 1.3.6.1.4.1.2590.1.1.4.1.4.1
Table for setting up the report of job history management information. If a device does not support all this functions, this table needs not to be implemented.
OBJECT-TYPE    
  SEQUENCE OF  
    MltJmReportEntry

mltJmReportEntry 1.3.6.1.4.1.2590.1.1.4.1.4.1.1
OBJECT-TYPE    
  MltJmReportEntry  

mltJmReportIndex 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.1
A unique value for each report destinations.
OBJECT-TYPE    
  INTEGER  

mltJmReportAddress 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.2
E-mail address of report destination.
OBJECT-TYPE    
  DisplayString SIZE(0..129)  

mltJmKeepAliveCount 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.3
The counter that controls existence of transmission to Job history information. Default shall set to 0 and, in 0, it shall not transmit to the specified address. A positive number is set when demanding transmission of Job history information. Transmission will be stopped, if it subtracts every 1 and is set to 0, whenever this counter will pass on the 1st. The side that demands transmission of Job history information makes transmission continue by rewriting this counter periodically. Moreover, when E-mail environment is not ready (grade to which the SMTP server is not set), display -1. When there is no transmitting control function, this value should be -3.
OBJECT-TYPE    
  INTEGER  

mltJmReportInterval 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.5
The number of cases that transmits Job history at once is set up.
OBJECT-TYPE    
  INTEGER notSend(0), each1(1), each10(2), each50(3), each100(4), each250(5), each500(6)  

mltJmReporIntervalSelection 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.6
The maximum of the number of cases to which once transmits Job history is shown.
OBJECT-TYPE    
  INTEGER notSend(0), each1(1), each10(2), each50(3), each100(4), each250(5), each500(6)  

mltJmReportRequest 1.3.6.1.4.1.2590.1.1.4.1.4.1.1.7
The request command of reporting job history. default : 0 send request : 1
OBJECT-TYPE    
  INTEGER  

mltDirectory 1.3.6.1.4.1.2590.2
OBJECT IDENTIFIER    

Defined Objects

CodedCharSet  
A coded character set value that specifies both a set of characters that may be used and an encoding (as one or more octets) that is used to represent the characters in the set. These values are to be used to identify the encoding employed for strings in the MIB where this is not fixed by the MIB.
TEXTUAL-CONVENTION    
  INTEGER other(1)  

MltPrtCommandEntry  
SEQUENCE    
  INTEGER as mltPrtCommandOnline  
  INTEGER as mltPrtCommandJobCancel  
  INTEGER as mltPrtCommandJobProceed  

MltPrtPrintPageEntry  
SEQUENCE    
  INTEGER as mltPrtPrintPageIndex  
  DisplayString as mltPrtPrintPageName  
  INTEGER as mltPrtPrintCommand  

MltPrtSysConfigEntry  
SEQUENCE    
  INTEGER as mltPrtJobLanguage  
  INTEGER as mltPrtPowerSave  
  INTEGER as mltPrtAutoContinue  
  INTEGER as mltPrtPaperTimeOut  
  INTEGER as mltPrtPsErrorPrint  

MltPrtPrintConfigEntry  
SEQUENCE    
  INTEGER as mltPrtCopies  
  INTEGER as mltPrtPaperSize  
  INTEGER as mltPrtPaperSource  
  INTEGER as mltPrtFineArt  
  INTEGER as mltPrtTonerSave  

MltPrtPclFontEntry  
SEQUENCE    
  INTEGER as mltPrtPclFontIndex  
  DisplayString as mltPrtPclFontName  
  INTEGER as mltPrtPclFontNumber  
  INTEGER as mltPrtPclFontSource  

MltPrtPsFontEntry  
SEQUENCE    
  INTEGER as mltPrtPsFontIndex  
  DisplayString as mltPrtPsFontName  
  INTEGER as mltPrtPsFontNumber  
  INTEGER as mltPrtPsFontSource  

MltPrtSymbolSetEntry  
SEQUENCE    
  INTEGER as mltPrtSymbolSetIndex  
  DisplayString as mltPrtSymbolSetName  
  INTEGER as mltPrtCharSetID  

MltPrtPaperSizeEntry  
SEQUENCE    
  INTEGER as mltPaperSizeIndex  
  DisplayString as mltPaperSizeName  
  INTEGER as mltPaperFeedDir  

MltPrtRemotePanelButtonEntry  
SEQUENCE    
  INTEGER as mltPrtPanelButtonIndex  
  DisplayString as mltPrtPanelButtonName  
  INTEGER as mltPrtPanelButtonPush  
  DisplayString as mltPrtPanelButtonDescr  

MltSysVersionEntry  
SEQUENCE    
  INTEGER as mltSysVersionIndex  
  DisplayString as mltSysVerName  
  DisplayString as mltSysVersionCode  
  DisplayString as mltSysVerDescr  

MltSysInputTrayEntry  
SEQUENCE    
  INTEGER as mltSysInputTrayIndex  
  INTEGER as mltSysInputTrayRefIndex  
  DisplayString as mltSysInputTrayName  
  INTEGER as mltSysInputTrayCapacitySence  
  INTEGER as mltSysInputTraySpecialPaper  
  INTEGER as mltSysInputTrayPaperAttribute  

MltSysOutputTrayEntry  
SEQUENCE    
  INTEGER as mltSysOutputTrayIndex  
  INTEGER as mltSysOutputTrayRefIndex  
  DisplayString as mltSysOutputTrayDefaultName  
  DisplayString as mltSysOutputTrayNickName  
  INTEGER as mltSysOutputTrayType  

MltSysPrintFunctionCounterEntry  
SEQUENCE    
  INTEGER as mltSysPrintFunctionColorIndex  
  INTEGER as mltSysPrintFunctionIndex  
  INTEGER as mltSysPrintFunctionColorType  
  INTEGER as mltSysPrintFunctionType  
  Integer32 as mltSysPrintFunctionTotalCount  
  Integer32 as mltSysPrintFunctionDuplexCount  
  Integer32 as mltSysPrintFunctionLargeSizeCount  
  Integer32 as mltSysPrintFunctionLargeDuplexCount  

MltSysSizeCounterEntry  
SEQUENCE    
  INTEGER as mltSysSizeFunctionIndex  
  INTEGER as mltSysSizeTypeIndex  
  INTEGER as mltSysSizeFunction  
  INTEGER as mltSysSizeType  
  Integer32 as mltSysSizeCount  

MltSysTonerLifeCounterEntry  
SEQUENCE    
  INTEGER as mltSysTonerTypeIndex  
  INTEGER as mltSysTonerType  
  Counter32 as mltTonerTypeCount  

MltNetGeneralEntry  
SEQUENCE    
  INTEGER as mltNetGeneralIndex  
  DisplayString as mltNetFirmVersion  
  PhysAddress as mltNetHardwareAddress  
  DisplayString as mltNetSerialNumber  
  INTEGER as mltNetSupportedConnector  
  INTEGER as mltNetCurrentConnector  
  INTEGER as mltNetSpeedConfig  
  INTEGER as mltNetInterfaceType  
  DisplayString as mltNetIfDescr  

MltNetProtocolEntry  
SEQUENCE    
  INTEGER as mltNetProtocolIfIndex  
  INTEGER as mltNetProtocolIndex  
  INTEGER as mltNetProtocolType  
  DisplayString as mltNetProtocolDescr  
  DisplayString as mltNetProtocolVer  
  INTEGER as mltNetProtocolOnOff  

MltNetCommandEntry  
SEQUENCE    
  INTEGER as mltNetCommandIfIndex  
  INTEGER as mltNetCommandReset  
  INTEGER as mltNetCommandDefault  
  INTEGER as mltNetCommandPrintNicConfig  
  INTEGER as mltNetCommandStartupConfig  
  INTEGER as mltNetCommandDownLoad  

MltNetSnmpCommEntry  
SEQUENCE    
  INTEGER as mltNetSnmpCommIndex  
  DisplayString as mltNetSnmpCommName  
  INTEGER as mltNetSnmpCommAccessRight  

MltNetSnmpTrapEntry  
SEQUENCE    
  INTEGER as mltNetSnmpTrapIfIndex  
  INTEGER as mltNetSnmpTrapIndex  
  DisplayString as mltNetSnmpTrapCommunity  
  IpAddress as mltNetSnmpTrapIpAddress  
  DisplayString as mltNetSnmpTrapIpxAddress  
  INTEGER as mltNetSnmpTrapOnOff  

MltNetTcpipGeneralEntry  
SEQUENCE    
  INTEGER as mltNetTcpipIfIndex  
  INTEGER as mltNetTcpipDefault  
  IpAddress as mltNetTcpipAddress  
  IpAddress as mltNetTcpipSubnet  
  IpAddress as mltNetTcpipGateway  
  INTEGER as mltNetTcpipUseBootProtocol  
  INTEGER as mltNetTcpipBootProtocolEnable  
  IpAddress as mltNetTcpipAddressServer  
  INTEGER as mltNetTcpipRawPortNumber  
  INTEGER as mltNetTcpipSupportService  
  INTEGER as mltNetTcpipDnsSupport  
  DisplayString as mltNetTcpipDnsHostName  
  DisplayString as mltNetTcpipDnsDomainName  

MltNetTcpipDnsEntry  
SEQUENCE    
  INTEGER as mltNetTcpipDnsIfIndex  
  INTEGER as mltNetTcpipDnsServerIndex  
  IpAddress as mltNetTcpipDnsServerAddress  

MltNetLpdGeneralEntry  
SEQUENCE    
  INTEGER as mltNetLpdIfIndex  
  INTEGER as mltNetLpdEnable  
  INTEGER as mltNetLpdPort  

MltNetLpdQueueEntry  
SEQUENCE    
  INTEGER as mltNetLpdQueueIfIndex  
  INTEGER as mltNetLpdQueueIndex  
  DisplayString as mltNetLpdQueueName  
  DisplayString as mltNetLpdQueueDescr  
  INTEGER as mltNetLpdQueueFilter  
  INTEGER as mltNetLpdQueueBanner  
  INTEGER as mltNetLpdQueueEnable  

MltNetFtpdGeneralEntry  
SEQUENCE    
  INTEGER as mltNetFtpdIfIndex  
  INTEGER as mltNetFtpdEnable  
  INTEGER as mltNetFtpdPort  

MltNetFtpdConfigEntry  
SEQUENCE    
  INTEGER as mltNetFtpdConfigIfIndex  
  INTEGER as mltNetFtpdUserIndex  
  DisplayString as mltNetFtpdUser  
  DisplayString as mltNetFtpdUserPassWd  
  INTEGER as mltNetFtpdCapability  
  DisplayString as mltNetFtpdDescr  

MltNetHttpdGeneralEntry  
SEQUENCE    
  INTEGER as mltNetHttpdIfIndex  
  INTEGER as mltNetHttpdEnable  
  INTEGER as mltNetHttpdPort  
  DisplayString as mltNetHttpdDescr  

MltNetSmtpGeneralEntry  
SEQUENCE    
  INTEGER as mltNetSmtpIfIndex  
  INTEGER as mltNetSmtpEnable  
  DisplayString as mltNetSmtpServerAddress  
  INTEGER as mltNetSmtpPort  

MltNetSmtpAccountEntry  
SEQUENCE    
  INTEGER as mltNetSmtpAccountIfIndex  
  INTEGER as mltNetSmtpAccountIndex  
  DisplayString as mltNetSmtpFromAddress  
  DisplayString as mltNetSmtpReplyAddress  
  INTEGER as mltNetSmtpConnTimeout  
  INTEGER as mltNetSmtpPurpose  
  DisplayString as mltNetSmtpDescription  

MltNetIppGeneralEntry  
SEQUENCE    
  INTEGER as mltNetIppGeneralIfIndex  
  INTEGER as mltNetIppServiceEnable  
  INTEGER as mltNetIppDefaultPortIndex  

MltNetIppPortEntry  
SEQUENCE    
  INTEGER as mltNetIppPortIfIndex  
  INTEGER as mltNetIppPortIndex  
  INTEGER as mltNetIppPortNumber  

MltNetIppPrtDescGeneralEntry  
SEQUENCE    
  INTEGER as mltIppPrtDescGeneralIfIndex  
  DisplayString as mltIppPrtName  
  DisplayString as mltIppPrtMoreInfo  
  INTEGER as mltIppPrtState  
  INTEGER as mltIppCharSetConfiguredIndex  
  INTEGER as mltIppNaturalLanguageConfiguredIndex  
  INTEGER as mltIppDocFormatDefaultIndex  
  INTEGER as mltIppPrinterIsAcceptingJobs  
  Counter as mltIppQueuedJobCount  
  INTEGER as mltIppColorSupported  
  INTEGER as mltIppPdlOverrideSupported  
  TimeTicks as mltIppPrinterUpTime  
  DisplayString as mltIppPrtLocation  
  DateAndTime as mltIppPrinterCurrentTime  

MltIppUriSupportedEntry  
SEQUENCE    
  INTEGER as mltIppUriIfIndex  
  INTEGER as mltIppUriIndex  
  DisplayString as mltIppUri  
  INTEGER as mltIppUriSecurity  
  INTEGER as mltIppUriAuthentication  

MltIppPrtStateReasonsEntry  
SEQUENCE    
  INTEGER as mltIppPrtStateReasonIfIndex  
  INTEGER as mltIppPrtStateReasonIndex  
  INTEGER as mltIppPrinterStateReason  
  INTEGER as mltIppPrtStateReasonSuffix  

MltIppVersionsSupportedEntry  
SEQUENCE    
  INTEGER as mltIppVersionIfIndex  
  INTEGER as mltIppVersionIndex  
  INTEGER as mltIppVersionType  

MltIppOperationSupportedEntry  
SEQUENCE    
  INTEGER as mltIppOperationIfIndex  
  INTEGER as mltIppOperationIndex  
  INTEGER as mltIppOperationType  
  INTEGER as mltIppOperationEnable  

MltIppCharSetSupportedEntry  
SEQUENCE    
  INTEGER as mltIppCharSetIfIndex  
  INTEGER as mltIppCharSetIndex  
  DisplayString as mltIppCharSetName  
  INTEGER as mltIppCharSetCode  

MltIppNaturalLanguageSupportedEntry  
SEQUENCE    
  INTEGER as mltIppNaturalLangIfIndex  
  INTEGER as mltIppNaturalLangIndex  
  DisplayString as mltIppNaturalLangName  

MltIppDocFormatSupportedEntry  
SEQUENCE    
  INTEGER as mltIppDocFormatIfIndex  
  INTEGER as mltIppDocFormatIndex  
  DisplayString as mltIppDocFormatName  

MltIppCompressionSupportedEntry  
SEQUENCE    
  INTEGER as mltIppCompressionIfIndex  
  INTEGER as mltIppCompressionIndex  
  INTEGER as mltIppCompressionType  

MltNetIppJobTemplateGeneralEntry  
SEQUENCE    
  INTEGER as mltIppJobTemplateGeneralIfIndex  
  INTEGER as mltIppJobPriorityDefault  
  INTEGER as mltIppJobPrioritySupported  
  INTEGER as mltIppJobHoldUntilDefault  
  INTEGER as mltIppJobSheetsDefault  
  INTEGER as mltIppCopiesDefault  
  INTEGER as mltIppCopiesMaxSupported  
  INTEGER as mltIppFinishingsDefault  
  INTEGER as mltIppPageRangesSupported  
  INTEGER as mltIppSidesDefault  
  INTEGER as mltIppNumberUpDefault  
  INTEGER as mltIppOrientationRequestedDefault  
  INTEGER as mltIppMediaDefault  
  INTEGER as mltIppPrinterResolutionDefault  
  INTEGER as mltIppPrintQualityDefault  

MltIppJobHoldUntilSupportedEntry  
SEQUENCE    
  INTEGER as mltIppJobHoldUntilIfIndex  
  INTEGER as mltIppJobHoldUntilIndex  
  INTEGER as mltIppJobHoldUntilType  

MltIppJobSheetsSupportedEntry  
SEQUENCE    
  INTEGER as mltIppJobSheetsIfIndex  
  INTEGER as mltIppJobSheetsIndex  
  INTEGER as mltIppJobSheetsType  

MltIppFinishingsSupportedEntry  
SEQUENCE    
  INTEGER as mltIppFinishingsIfIndex  
  INTEGER as mltIppFinishingsIndex  
  INTEGER as mltIppFinishingsType  

MltIppSidesSupportedEntry  
SEQUENCE    
  INTEGER as mltIppSidesIfIndex  
  INTEGER as mltIppSidesIndex  
  INTEGER as mltIppSidesType  

MltIppNumberUpSupportedEntry  
SEQUENCE    
  INTEGER as mltIppNumberUpIfIndex  
  INTEGER as mltIppNumberUpIndex  
  INTEGER as mltIppNumberUpType  

MltIppOrientationRequestedSupportedEntry  
SEQUENCE    
  INTEGER as mltIppOrientationRequestedIfIndex  
  INTEGER as mltIppOrientationRequestedIndex  
  INTEGER as mltIppOrientationRequestedType  

MltIppMediaSupportedEntry  
SEQUENCE    
  INTEGER as mltIppMediaIfIndex  
  INTEGER as mltIppMediaIndex  
  OCTET STRING as mltIppMediaName  
  OCTET STRING as mltIppMediaType  
  OCTET STRING as mltIppMediaColor  
  OCTET STRING as mltIppMediaInputTray  

MltPrinterResolutionSupportedEntry  
SEQUENCE    
  INTEGER as mltPrinterResolutionIfIndex  
  INTEGER as mltPrinterResolutionIndex  
  Integer32 as mltPrinterResolutionFeedDir  
  Integer32 as mltPrinterResolutionXFeedDir  
  INTEGER as mltPrinterResolutionUnit  

MltPrintQualitySupportedEntry  
SEQUENCE    
  INTEGER as mltPrintQualityIfIndex  
  INTEGER as mltPrintQualityIndex  
  INTEGER as mltPrintQualityType  

MltNetSlpGeneralEntry  
SEQUENCE    
  INTEGER as mltNetSlpIfIndex  
  INTEGER as mltNetSlpEnable  
  INTEGER as mltNetSlpPortNumber  
  INTEGER as mltNetSlpMTU  
  INTEGER as mltNetSlpTTL  
  INTEGER as mltNetSlpBroadcastSupport  

MltNetSlpConfigEntry  
SEQUENCE    
  INTEGER as mltNetSlpConfigIfIndex  
  INTEGER as mltNetSlpIndex  
  DisplayString as mltNetSlpService  
  DisplayString as mltNetSlpScope  
  INTEGER as mltNetSlpLifetime  

MltNetNwGeneralEntry  
SEQUENCE    
  INTEGER as mltNetNwIfIndex  
  INTEGER as mltNetNwDefault  
  INTEGER as mltNetNwFrameTypeConfig  
  INTEGER as mltNetNwPrintMode  

MltNetNwFrameEntry  
SEQUENCE    
  INTEGER as mltNetNwFrameIfIndex  
  INTEGER as mltNetNwFrameIndex  
  INTEGER as mltNetNwFrameType  
  OCTET STRING as mltNetNwNetworkNumber  

MltNetNwPserverEntry  
SEQUENCE    
  INTEGER as mltNetNwPsIfIndex  
  INTEGER as mltNetNwPsIndex  
  DisplayString as mltNetNwPsName  
  DisplayString as mltNetNwPsPasswd  
  INTEGER as mltNetNwPsMode  
  DisplayString as mltNetNwPsPrefFServer  
  DisplayString as mltNetNwPsPrefTree  
  DisplayString as mltNetNwPsPrefContext  
  INTEGER as mltNetNwPsPollingRate  

MltNetNwQueueEntry  
SEQUENCE    
  INTEGER as mltNetNwQueueIndex  
  DisplayString as mltNetNwQueueName  
  INTEGER as mltNetNwQueueRefIfIndex  
  INTEGER as mltNetNwQueueRefPsIndex  
  INTEGER as mltNetNwQueueStatus  

MltNetNwNPrinterEntry  
SEQUENCE    
  INTEGER as mltNetNwNPrinterIfIndex  
  INTEGER as mltNetNwNPrinterIndex  
  DisplayString as mltNetNwNPrinterName  
  INTEGER as mltNetNwNPrinterNumber  

MltNetAppleTalkGeneralEntry  
SEQUENCE    
  INTEGER as mltNetAtIfIndex  
  INTEGER as mltNetAtDefault  
  INTEGER as mltNetAtNetNumber  
  INTEGER as mltNetAtNodeNumber  
  DisplayString as mltNetAtDesiredZone  
  DisplayString as mltNetAtCurrentZone  

MltNetAtPrinterEntry  
SEQUENCE    
  INTEGER as mltNetAtPrinterIfIndex  
  INTEGER as mltNetAtPrinterIndex  
  DisplayString as mltNetAtPrinterName  
  DisplayString as mltNetAtPrinterType  

MltNetSmbGeneralEntry  
SEQUENCE    
  INTEGER as mltNetSmbIfIndex  
  INTEGER as mltNetSmbDefault  
  DisplayString as mltNetSmbWorkGroupName  
  DisplayString as mltNetSmbHostName  
  INTEGER as mltNetSmbWinsSupport  
  IpAddress as mltNetSmbWinsPrimaryServer  
  IpAddress as mltNetSmbWinsSecondaryServer  

MltNetSmbPrinterEntry  
SEQUENCE    
  INTEGER as mltNetSmbPrinterIfIndex  
  INTEGER as mltNetSmbPrinterIndex  
  DisplayString as mltNetSmbPrinterName  
  DisplayString as mltNetSmbPrinterDescr  

MltJmGeneralEntry  
SEQUENCE    
  INTEGER as mltJmGeneralJobSetIndex  
  INTEGER as mltJmGeneralNumberOfActiveJobs  
  INTEGER as mltJmGeneralOldestActiveJobIndex  
  INTEGER as mltJmGeneralNewestActiveJobIndex  
  INTEGER as mltJmGeneralJobPersistence  
  INTEGER as mltJmGeneralJobSetType  

MltJmJobEntry  
SEQUENCE    
  INTEGER as mltJmJobJobSetIndex  
  INTEGER as mltJmJobIndex  
  INTEGER as mltJmJobFunction  
  INTEGER as mltJmJobStatus  
  DateAndTime as mltJmJobReceivedTime  
  DateAndTime as mltJmJobCompleteTime  
  INTEGER as mltJmJobPriority  
  INTEGER as mltJmJobDivNumber  
  DisplayString as mltJmJobOwner  
  INTEGER as mltJmJobType  
  DisplayString as mltJmJobName  
  Integer32 as mltJmJobDocPageNumbers  
  Integer32 as mltJmJobDocCopyNumbers  
  INTEGER as mltJmJobPageSize  
  DisplayString as mltJmJobDestination  
  Integer32 as mltJmJobDataSize  
  INTEGER as mltJmJobColorMode  
  INTEGER as mltJmJobFormat  
  INTEGER as mltJmJobXResolution  
  INTEGER as mltJmJobYResolution  
  INTEGER as mltJmJobDuplex  
  Integer32 as mltJmJobOutputPages  
  Integer32 as mltJmJobOutputSheets  
  INTEGER as mltJmJobMediaType  

MltJmReportEntry  
SEQUENCE    
  INTEGER as mltJmReportIndex  
  DisplayString as mltJmReportAddress  
  INTEGER as mltJmKeepAliveCount  
  INTEGER as mltJmReportInterval  
  INTEGER as mltJmReporIntervalSelection  
  INTEGER as mltJmReportRequest