MICROSENS-CWDM8-MIB
File:
MICROSENS-CWDM8-MIB.mib (41390 bytes)
Imported modules
Imported symbols
Defined Objects
| cwdm |
1.3.6.1.4.1.3181.6 |
| OBJECT IDENTIFIER |
|
|
|
| deviceTableEntry |
1.3.6.1.4.1.3181.6.4.1.1 |
| An entry in the port table. |
| OBJECT-TYPE |
|
|
|
| |
DeviceList |
|
|
| deviceTemperature |
1.3.6.1.4.1.3181.6.4.1.1.5 |
| This entry describes the temperature of the device in degree centigrade. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| deviceTempAlarmThreshold |
1.3.6.1.4.1.3181.6.4.1.1.6 |
| This entry describes the current temperature-alarm threshold value of the device in degree centigrade. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| deviceTempAlarm |
1.3.6.1.4.1.3181.6.4.1.1.7 |
| This entry describes if a temperature-alarm condition has occurred or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
alarm(1), no-alarm(0), unknown(-255) |
|
| deviceTempShutdown |
1.3.6.1.4.1.3181.6.4.1.1.8 |
| This entry describes if a temperature-shutdown condition has occurred or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
alarm(1), no-alarm(0), unknown(-255) |
|
| deviceTrPowerFailureAlarm |
1.3.6.1.4.1.3181.6.4.1.1.9 |
| This entry describes if a transceiver-board power-supply-alarm condition has occurred or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
no-alarm(0), alarm-channel-1-4(1), alarm-channel-5-8(2), alarm-channel-1-8(3), unknown(-255) |
|
| deviceMinorAlarm |
1.3.6.1.4.1.3181.6.4.1.1.10 |
| This entry describes if a minor-alarm condition has occurred or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
alarm(1), no-alarm(0), unknown(-255) |
|
| deviceMajorAlarm |
1.3.6.1.4.1.3181.6.4.1.1.11 |
| This entry describes if a major-alarm condition has occurred or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
alarm(1), no-alarm(0), unknown(-255) |
|
| portTableEntry |
1.3.6.1.4.1.3181.6.4.2.1 |
| An entry in the port table. |
| OBJECT-TYPE |
|
|
|
| |
PortList |
|
|
| portId |
1.3.6.1.4.1.3181.6.4.2.1.1 |
| This entry describes the port id. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| portChannelEnabled |
1.3.6.1.4.1.3181.6.4.2.1.2 |
| This entry describes the channel's status. A value of 1 indicates that the channel is enabled, a value of 0 indicates that the channel is not enabled. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disabled(0), enabled(1), unknown(-255) |
|
| portLinkThroughLocalLine |
1.3.6.1.4.1.3181.6.4.2.1.3 |
| This entry describes the local-line link-through-status of the port. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disabled(0), enabled(1), unknown(-255) |
|
| portLinkThroughLineLocal |
1.3.6.1.4.1.3181.6.4.2.1.4 |
| This entry describes the line-local link-through-status of the port. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
disabled(0), enabled(1), unknown(-255) |
|
| portLocalModuleInstalled |
1.3.6.1.4.1.3181.6.4.2.1.5 |
| This entry describes if a local transceiver module is installed or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
not-installed(0), installed(1), unknown(-255) |
|
| portLineModuleInstalled |
1.3.6.1.4.1.3181.6.4.2.1.6 |
| This entry describes if a line transceiver module is installed or not. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
not-installed(0), installed(1), unknown(-255) |
|
| portLocalLink |
1.3.6.1.4.1.3181.6.4.2.1.7 |
| This entry describes the port's local link status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
off(0), on(1), unknown(-255) |
|
| portLineLink |
1.3.6.1.4.1.3181.6.4.2.1.8 |
| This entry describes the port's line link status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
off(0), on(1), unknown(-255) |
|
| portLocalTxFault |
1.3.6.1.4.1.3181.6.4.2.1.9 |
| This entry describes the port's local-tx-fault status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
no-error(0), error(1), unknown(-255) |
|
| portLineTxFault |
1.3.6.1.4.1.3181.6.4.2.1.10 |
| This entry describes the port's line-tx-fault status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
no-error(0), error(1), unknown(-255) |
|
| portLocalPowerFault |
1.3.6.1.4.1.3181.6.4.2.1.11 |
| This entry describes the port's local-power-fault status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
no-error(0), error(1), unknown(-255) |
|
| portLinePowerFault |
1.3.6.1.4.1.3181.6.4.2.1.12 |
| This entry describes the port's line-power-fault status. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
no-error(0), error(1), unknown(-255) |
|
| portRateSelect |
1.3.6.1.4.1.3181.6.4.2.1.13 |
| This entry describes the port's local data rate. A value of 1 describes full data rate, a value of 0 describes reduced data rate. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
reduced(0), full(1), unknown(-255) |
|
| localModuleTableEntry |
1.3.6.1.4.1.3181.6.4.3.1 |
| An entry in the local module table. |
| OBJECT-TYPE |
|
|
|
| |
LocalModuleList |
|
|
| localModuleConnector |
1.3.6.1.4.1.3181.6.4.3.1.2 |
| This entry describes the connector-type of the port. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), sc(1), style1-copper(2), style2-copper(3), bnc-tnc(4), coaxial-headers(5), fiberjack(6), lc(7), mt-rj(8), mu(9), sg(10), opticalpigtail(11), hssdc2(32), copperpigtail(33) |
|
| localModuleTrCodeSonet |
1.3.6.1.4.1.3181.6.4.3.1.3 |
| This entry describes the SONET compliance of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), oc3-multi-mode-short-reach(1), oc3-single-mode-intermediate-reach(2), oc3-single-mode-long-reach(4), oc12-multi-mode-short-reach(16), oc12-single-mode-intermediate-reach(32), oc12-single-mode-long-reach(64), oc48-short-reach(128), oc48-intermediate-reach(256), oc48-long-reach(512) |
|
| localModuleTrCodeGigabit |
1.3.6.1.4.1.3181.6.4.3.1.4 |
| This entry describes the Gigabit Ethernet compliance of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), base-1000-sx(1), base-1000-lx(2), base-1000-cx(4), base-1000-t(8) |
|
| localModuleTrCodeFbLinkLength |
1.3.6.1.4.1.3181.6.4.3.1.5 |
| This entry describes the fibre channel link length of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), long-distance(1), intermediate-distance(2), short-distance(4) |
|
| localModuleTrCodeFbTrTech |
1.3.6.1.4.1.3181.6.4.3.1.6 |
| This entry describes the fibre channel transmitter technology of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), longwave-laser-LL(1), shortwave-laser-OFC(2), shortwave-laser-no-OFC(4), electrical-intra-enclosure(8), electrical-inter-enclosure(16), longwave-laser-LC(32) |
|
| localModuleTrCodeFbSpeed |
1.3.6.1.4.1.3181.6.4.3.1.8 |
| This entry describes the fibre channel speed of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), speed-100MBytes-per-sec(1), speed-200MBytes-per-sec(4), speed-400MBytes-per-sec(16) |
|
| localModuleBrNominal |
1.3.6.1.4.1.3181.6.4.3.1.9 |
| This entry describes the nominal bit rate, specified in units of 100 Megabits per second. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| localModuleLength9km |
1.3.6.1.4.1.3181.6.4.3.1.10 |
| This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the transceiver supports a link length greater than 254 km. A value of zero means that the transceiver does not support single-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| localModuleLength9m |
1.3.6.1.4.1.3181.6.4.3.1.11 |
| This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link length greater than 25.4 km. A value of zero means that the transceiver does not support single-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| localModuleLength50 |
1.3.6.1.4.1.3181.6.4.3.1.12 |
| This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multi-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| localModuleLength62 |
1.3.6.1.4.1.3181.6.4.3.1.13 |
| This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| localModuleLengthCopper |
1.3.6.1.4.1.3181.6.4.3.1.14 |
| This entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link length greater than 254 m. A value of zero means that the transceiver does not support copper cables. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleTableEntry |
1.3.6.1.4.1.3181.6.4.4.1 |
| An entry in the line module table. |
| OBJECT-TYPE |
|
|
|
| |
LineModuleList |
|
|
| lineModuleConnector |
1.3.6.1.4.1.3181.6.4.4.1.2 |
| This entry describes the connector-type of the port. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), sc(1), style1-copper(2), style2-copper(3), bnc-tnc(4), coaxial-headers(5), fiberjack(6), lc(7), mt-rj(8), mu(9), sg(10), opticalpigtail(11), hssdc2(32), copperpigtail(33) |
|
| lineModuleTrCodeSonet |
1.3.6.1.4.1.3181.6.4.4.1.3 |
| This entry describes the SONET compliance of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), oc3-multi-mode-short-reach(1), oc3-single-mode-intermediate-reach(2), oc3-single-mode-long-reach(4), oc12-multi-mode-short-reach(16), oc12-single-mode-intermediate-reach(32), oc12-single-mode-long-reach(64), oc48-short-reach(128), oc48-intermediate-reach(256), oc48-long-reach(512) |
|
| lineModuleTrCodeGigabit |
1.3.6.1.4.1.3181.6.4.4.1.4 |
| This entry describes the Gigabit Ethernet compliance of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), base-1000-SX(1), base-1000-LX(2), base-1000-CX(4), base-1000-T(8) |
|
| lineModuleTrCodeFbLinkLength |
1.3.6.1.4.1.3181.6.4.4.1.5 |
| This entry describes the fibre channel link length of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), long-distance(1), intermediate-distance(2), short-distance(4) |
|
| lineModuleTrCodeFbTrTech |
1.3.6.1.4.1.3181.6.4.4.1.6 |
| This entry describes the fibre channel transmitter technology of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), longwave-laser-LL(1), shortwave-laser-OFC(2), shortwave-laser-no-OFC(4), electrical-intra-enclosure(8), electrical-inter-enclosure(16), longwave-laser-LC(32) |
|
| lineModuleTrCodeFbSpeed |
1.3.6.1.4.1.3181.6.4.4.1.8 |
| This entry describes the fibre channel speed of the transceiver. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(0), speed-100MBytes-per-sec(1), speed-200MBytes-per-sec(4), speed-400MBytes-per-sec(16) |
|
| lineModuleBrNominal |
1.3.6.1.4.1.3181.6.4.4.1.9 |
| This entry describes the nominal bit rate, specified in units of 100 Megabits per second. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleLength9km |
1.3.6.1.4.1.3181.6.4.4.1.10 |
| This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the transceiver supports a link length greater than 254 km. A value of zero means that the transceiver does not support single-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleLength9m |
1.3.6.1.4.1.3181.6.4.4.1.11 |
| This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link length greater than 25.4 km. A value of zero means that the transceiver does not support single-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleLength50 |
1.3.6.1.4.1.3181.6.4.4.1.12 |
| This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multi-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleLength62 |
1.3.6.1.4.1.3181.6.4.4.1.13 |
| This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineModuleLengthCopper |
1.3.6.1.4.1.3181.6.4.4.1.14 |
| This entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link length greater than 254 m. A value of zero means that the transceiver does not support copper cables. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| powerTableEntry |
1.3.6.1.4.1.3181.6.4.5.1 |
| An entry in the power-supply table. |
| OBJECT-TYPE |
|
|
|
| |
PowerList |
|
|
| powerId |
1.3.6.1.4.1.3181.6.4.5.1.1 |
| This entry describes the power-supply module id. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| powerTemperature |
1.3.6.1.4.1.3181.6.4.5.1.5 |
| This entry describes the temperature of the power-supply module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| powerStatus |
1.3.6.1.4.1.3181.6.4.5.1.6 |
| This entry describes the operational status of the power-supply module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), not-active(0), active(1) |
|
| powerSuppliedPower |
1.3.6.1.4.1.3181.6.4.5.1.7 |
| This entry describes the power output of the power-supply module in watt. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| powerLoad |
1.3.6.1.4.1.3181.6.4.5.1.8 |
| This entry describes the load level of the power-supply module in percent. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| powerFanStatus |
1.3.6.1.4.1.3181.6.4.5.1.9 |
| This entry describes the fan status of the power-supply module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), not-active(0), active(1) |
|
| lineIfTableEntry |
1.3.6.1.4.1.3181.6.4.6.1 |
| An entry in the line-interface table. |
| OBJECT-TYPE |
|
|
|
| |
LineIfList |
|
|
| lineIfId |
1.3.6.1.4.1.3181.6.4.6.1.1 |
| This entry describes the power-supply module id. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| lineIfWestLinkStatus |
1.3.6.1.4.1.3181.6.4.6.1.4 |
| This entry describes the west-link status of the interface module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), off(0), on(1) |
|
| lineIfEastLinkStatus |
1.3.6.1.4.1.3181.6.4.6.1.5 |
| This entry describes the east-link status of the interface module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), off(0), on(1) |
|
| lineIfWestChannelStatus |
1.3.6.1.4.1.3181.6.4.6.1.6 |
| This entry describes the west-channel status of the interface module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), not-in-use(0), in-use(1) |
|
| lineIfEastChannelStatus |
1.3.6.1.4.1.3181.6.4.6.1.7 |
| This entry describes the east-channel status of the interface module. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255), not-in-use(0), in-use(1) |
|
| lineIfWestLinkRcvPower |
1.3.6.1.4.1.3181.6.4.6.1.8 |
| This entry describes the west-link receive power of the interface module in micro watts. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| lineIfEastLinkRcvPower |
1.3.6.1.4.1.3181.6.4.6.1.9 |
| This entry describes the east-link receive power of the interface module in micro watts. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(-255) |
|
| passiveTableEntry |
1.3.6.1.4.1.3181.6.4.7.1 |
| An entry in the passive table. |
| OBJECT-TYPE |
|
|
|
| |
PassiveList |
|
|
| passiveId |
1.3.6.1.4.1.3181.6.4.7.1.1 |
| This entry describes the passive optical module id. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| channelCount |
1.3.6.1.4.1.3181.6.4.100 |
| This entry describes the number of channels in the CWDM-system. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
Defined Objects
| DeviceList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as deviceId |
|
|
| |
DisplayString as deviceArtNo |
|
|
| |
DisplayString as deviceSerNo |
|
|
| |
DisplayString as deviceDesc |
|
|
| |
INTEGER as deviceTemperature |
|
|
| |
INTEGER as deviceTempAlarmThreshold |
|
|
| |
INTEGER as deviceTempAlarm |
|
|
| |
INTEGER as deviceTempShutdown |
|
|
| |
INTEGER as deviceTrPowerFailureAlarm |
|
|
| |
INTEGER as deviceMinorAlarm |
|
|
| |
INTEGER as deviceMajorAlarm |
|
|
| PortList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as portId |
|
|
| |
INTEGER as portChannelEnabled |
|
|
| |
INTEGER as portLinkThroughLocalLine |
|
|
| |
INTEGER as portLinkThroughLineLocal |
|
|
| |
INTEGER as portLocalModuleInstalled |
|
|
| |
INTEGER as portLineModuleInstalled |
|
|
| |
INTEGER as portLocalLink |
|
|
| |
INTEGER as portLineLink |
|
|
| |
INTEGER as portLocalTxFault |
|
|
| |
INTEGER as portLineTxFault |
|
|
| |
INTEGER as portLocalPowerFault |
|
|
| |
INTEGER as portLinePowerFault |
|
|
| |
INTEGER as portRateSelect |
|
|
| LocalModuleList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as localModuleId |
|
|
| |
INTEGER as localModuleConnector |
|
|
| |
INTEGER as localModuleTrCodeSonet |
|
|
| |
INTEGER as localModuleTrCodeGigabit |
|
|
| |
INTEGER as localModuleTrCodeFbLinkLength |
|
|
| |
INTEGER as localModuleTrCodeFbTrTech |
|
|
| |
INTEGER as localModuleTrCodeFbTrMedia |
|
|
| |
INTEGER as localModuleTrCodeFbSpeed |
|
|
| |
INTEGER as localModuleBrNominal |
|
|
| |
INTEGER as localModuleLength9km |
|
|
| |
INTEGER as localModuleLength9m |
|
|
| |
INTEGER as localModuleLength50 |
|
|
| |
INTEGER as localModuleLength62 |
|
|
| |
INTEGER as localModuleLengthCopper |
|
|
| |
DisplayString as localModuleVendorSN |
|
|
| |
DisplayString as localModuleDateCode |
|
|
| |
INTEGER as localModuleLaserCurrent |
|
|
| |
INTEGER as localModuleTransmittedPower |
|
|
| |
INTEGER as localModuleReceivedPower |
|
|
| |
INTEGER as localModuleLaserTemperature |
|
|
| |
INTEGER as localModuleVoltage |
|
|
| LineModuleList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as lineModuleId |
|
|
| |
INTEGER as lineModuleConnector |
|
|
| |
INTEGER as lineModuleTrCodeSonet |
|
|
| |
INTEGER as lineModuleTrCodeGigabit |
|
|
| |
INTEGER as lineModuleTrCodeFbLinkLength |
|
|
| |
INTEGER as lineModuleTrCodeFbTrTech |
|
|
| |
INTEGER as lineModuleTrCodeFbTrMedia |
|
|
| |
INTEGER as lineModuleTrCodeFbSpeed |
|
|
| |
INTEGER as lineModuleBrNominal |
|
|
| |
INTEGER as lineModuleLength9km |
|
|
| |
INTEGER as lineModuleLength9m |
|
|
| |
INTEGER as lineModuleLength50 |
|
|
| |
INTEGER as lineModuleLength62 |
|
|
| |
INTEGER as lineModuleLengthCopper |
|
|
| |
DisplayString as lineModuleVendorSN |
|
|
| |
DisplayString as lineModuleDateCode |
|
|
| |
INTEGER as lineModuleLaserCurrent |
|
|
| |
INTEGER as lineModuleTransmittedPower |
|
|
| |
INTEGER as lineModuleReceivedPower |
|
|
| |
INTEGER as lineModuleLaserTemperature |
|
|
| |
INTEGER as lineModuleVoltage |
|
|
| PowerList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as powerId |
|
|
| |
DisplayString as powerArtNo |
|
|
| |
DisplayString as powerSerNo |
|
|
| |
DisplayString as powerDesc |
|
|
| |
INTEGER as powerTemperature |
|
|
| |
INTEGER as powerStatus |
|
|
| |
INTEGER as powerSuppliedPower |
|
|
| |
INTEGER as powerLoad |
|
|
| |
INTEGER as powerFanStatus |
|
|
| LineIfList |
|
| SEQUENCE |
|
|
|
| |
INTEGER as lineIfId |
|
|
| |
DisplayString as lineIfArtNo |
|
|
| |
DisplayString as lineIfSerNo |
|
|
| |
INTEGER as lineIfWestLinkStatus |
|
|
| |
INTEGER as lineIfEastLinkStatus |
|
|
| |
INTEGER as lineIfWestChannelStatus |
|
|
| |
INTEGER as lineIfEastChannelStatus |
|
|
| |
INTEGER as lineIfWestLinkRcvPower |
|
|
| |
INTEGER as lineIfEastLinkRcvPower |
|
|