MSSSERVER8260-MIB
File:
MSSSERVER8260-MIB.mib (8686 bytes)
Imported modules
Imported symbols
Defined Objects
| ibm |
1.3.6.1.4.1.2 |
| OBJECT IDENTIFIER |
|
|
|
| ibmProd |
1.3.6.1.4.1.2.6 |
| OBJECT IDENTIFIER |
|
|
|
| nwaysMSS |
1.3.6.1.4.1.2.6.118 |
| OBJECT IDENTIFIER |
|
|
|
| mss8260ResetFlag |
1.3.6.1.4.1.2.6.118.3.1.1 |
| The flag that controls the reset process in this blade. This variable shall assume a value of noreset(1) in the absence of a request for a reset from the management application. This variable shall assume a value of reboot(2) if the management application requests that this blade execute a complete hardware reboot which reloads the code load from storage. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
noreset(1), reboot(2) |
|
| mss8260DRAMinstalled |
1.3.6.1.4.1.2.6.118.3.1.2 |
| The total amount of dynamic RAM installed on this blade. The amount is in units of megabytes. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| mss8260NotifyStatus |
1.3.6.1.4.1.2.6.118.3.1.3 |
| The status of the trap reporting service in this blade. This variable shall assume a value of enabled(1) if this blade is permitted to send traps. This variable shall assume a value of disabled(2) if this blade is prohibited from sending traps. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
enabled(1), disabled(2) |
|
| mss8260TempThresholdStatus |
1.3.6.1.4.1.2.6.118.3.1.4 |
| The status of the temperature in this blade. This variable shall assume a value of normal(1) if the temperature is within proper operating range for this blade. This variable shall assume a value of warning(2) if the temperature becomes elevated but this blade can still operate. This variable shall assume a value of shutdown(3) if the temperature is beyond the operating limits of this blade. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
normal(1), warning(2), shutdown(3) |
|
| mssServer8260ELSTrapV2 |
1.3.6.1.4.1.2.6.118.3.2 |
| The trap announces an Event Logging System (ELS) event occurred. The variable proElsSubSysEventMsg provides a textual description of the event. The variable is in one of two formats. If ELS timestamping is enabled, the format is hr:min:sec subsys_name.event_num: message_text. An example would be 09:32:56 IP.008: no rte 9.7.1.8 -> 9.7.4.3 dsc. If ELS timestamping is disabled, the format is subsys_name.event_num: message_text. An example would be IP.008: no rte 9.7.1.8 -> 9.7.4.3 dsc. |
| TRAP-TYPE |
|
|
|
| |
proElsSubSysEventMsg |
|
|
| mss8260PCAdapEntry |
1.3.6.1.4.1.2.6.118.3.2.2.1 |
| A PC adapter entry containing objects to describe the operational aspects of the PC adapter on this blade. |
| OBJECT-TYPE |
|
|
|
| |
Mss8260PCAdapEntry |
|
|
| mss8260PCAdapSlotNum |
1.3.6.1.4.1.2.6.118.3.2.2.1.1 |
| The relative slot location at which the adapter is attached to this blade. Slots are numbered from 1 to 2 (bottom to top) when facing this blade. This variable serves as the index for the mss8260PCAdapTable. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
|
|
| mss8260PCAdapType |
1.3.6.1.4.1.2.6.118.3.2.2.1.2 |
| The type of PC adapter that is inserted into this slot. The variable shall assume a value of unknown(1) if the adapter in the slot is not supported by this blade. The variable shall assume a value of harddrive(2) if the slot contains a PC disk drive. The variable shall assume a value of modem(3) if the slot contains a PC data/fax/voice modem. The variable shall assume a value of flashcard(5) if the slot contains a PC flash card. This variable shall assume a value of notPresent(4), when a PC card is not plugged into the corrisponding slot. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
unknown(1), harddrive(2), modem(3), notPresent(4), flashcard(5) |
|
| mss8260PCAdapTypeChg |
1.3.6.1.4.1.2.6.118.3.3 |
| The trap announces a change in the type of PC card. It shall be sent if the value of the mss8260PCAdapType changes and mss8260NotifyStatus has a value of enabled(1). |
| TRAP-TYPE |
|
|
|
| |
mss8260PCAdapType |
|
|
Defined Objects
| Mss8260PCAdapEntry |
|
| SEQUENCE |
|
|
|
| |
INTEGER as mss8260PCAdapSlotNum |
|
|
| |
INTEGER as mss8260PCAdapType |
|
|