| RFC1155-SMI | RFC-1212 |
| Counter | enterprises | OBJECT-TYPE |
| codex | 1.3.6.1.4.1.449 | ||
| OBJECT IDENTIFIER | |||
| cdxProductSpecific | 1.3.6.1.4.1.449.2 | ||
| OBJECT IDENTIFIER | |||
| cdx6500 | 1.3.6.1.4.1.449.2.1 | ||
| OBJECT IDENTIFIER | |||
| cdx6500Configuration | 1.3.6.1.4.1.449.2.1.2 | ||
| OBJECT IDENTIFIER | |||
| cdx6500CfgProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1 | ||
| OBJECT IDENTIFIER | |||
| cdx6500PCTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.1 | ||
| OBJECT IDENTIFIER | |||
| cdx6500PPCTMX25PortTables | 1.3.6.1.4.1.449.2.1.2.1.1.4 | ||
| OBJECT IDENTIFIER | |||
| cdx6500PPCTMX25PortTable | 1.3.6.1.4.1.449.2.1.2.1.1.4.1 | ||
| All of the common configuration parameters relevant to the MX.25 port table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500PPCTMX25PortEntry | |||
| cdx6500PPCTMX25PortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1 | ||
| A row of MX.25 Port configuration parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500PPCTMX25PortEntry | |||
| cdx6500mx25pCfgPortNum | 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1.1 | ||
| MX25 Port Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25pSubType | 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1.2 | ||
| This is the mode in which this MX25 port will run. newvalMaster : same functionality as 'master', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | master(0), slave(1), newvalMaster(50) | ||
| cdx6500PPCTMX25MPortTable | 1.3.6.1.4.1.449.2.1.2.1.1.4.2 | ||
| All of the configuration parameters relevant to the MX.25 Master port table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500PPCTMX25MPortEntry | |||
| cdx6500PPCTMX25MPortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1 | ||
| A row of MX.25 Master Port configuration parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500PPCTMX25MPortEntry | |||
| cdx6500mx25mpCfgPortNum | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.1 | ||
| MX25 Port Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25mpSubType | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.2 | ||
| This is the mode in which this MX25 port will run. newvalMaster : same functionality as 'master', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | master(0), newvalMaster(50) | ||
| cdx6500mx25mpClockSource | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.3 | ||
| int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration added for RFc1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | int(0), ext(1), newvalInt(50) | ||
| cdx6500mx25mpClockSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.4 | ||
| This is the speed of the port in bits per second, when using internal clocking. | |||
| OBJECT-TYPE | |||
| INTEGER | 1200..80000 | ||
| cdx6500mx25mpStationCnt | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.5 | ||
| The number of slave stations on the MX25 line. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..32 | ||
| cdx6500mx25mpPollTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.6 | ||
| Worst case delay for a slave to respond to a poll frame sent by the master, including modem turn around time, etc. Value in 10ths of second ( 30 = 3.0 seconds ). | |||
| OBJECT-TYPE | |||
| INTEGER | 1..255 | ||
| cdx6500mx25mpPollPeriod | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.7 | ||
| Time in milliseconds between polls when no data is exchanged. | |||
| OBJECT-TYPE | |||
| INTEGER | 50..250 | ||
| cdx6500mx25mpTries | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.8 | ||
| Maximum number of attempts to complete a transmission. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..16 | ||
| cdx6500mx25mpRestartTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.9 | ||
| Restart-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25mpResetTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.10 | ||
| Reset-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25mpCallTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.11 | ||
| Call-Request timeout timer in seconds. If timer expires, call is cleared. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..200 | ||
| cdx6500mx25mpClearTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.12 | ||
| Clear-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25mpPortControl | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.13 | ||
| Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(2..8) | ||
| cdx6500mx25mpTXEncoding | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.14 | ||
| This is the data encoding used on the MX25 link. nrz - Non Return to Zero. nrzi - Non Return to Zero Inverted. newvalNrz : same functionality as 'nrz', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | nrz(0), nrzi(1), newvalNrz(50) | ||
| cdx6500mx25mpElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.15 | ||
| Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled | |||
| OBJECT-TYPE | |||
| INTEGER | v24(1), v35(2), v36(3), x21(4), none(5) | ||
| cdx6500mx25mpV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.16 | ||
| Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal | |||
| OBJECT-TYPE | |||
| INTEGER | ri(1), tm(2) | ||
| cdx6500mx25mpHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.17 | ||
| Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable | |||
| OBJECT-TYPE | |||
| INTEGER | none(1), xover(2) | ||
| cdx6500PPCTMX25SPortTable | 1.3.6.1.4.1.449.2.1.2.1.1.4.3 | ||
| All of the configuration parameters relevant to the MX.25 Slave port table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500PPCTMX25SPortEntry | |||
| cdx6500PPCTMX25SPortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1 | ||
| A row of MX.25 Slave Port configuration parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500PPCTMX25SPortEntry | |||
| cdx6500mx25spCfgPortNum | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.1 | ||
| MX25 Port Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25spSubType | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.2 | ||
| This is the mode in which this MX25 port will run. | |||
| OBJECT-TYPE | |||
| INTEGER | slave(1) | ||
| cdx6500mx25spClockSource | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.3 | ||
| int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | int(0), ext(1), newvalInt(50) | ||
| cdx6500mx25spClockSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.4 | ||
| This is the speed of the port in bits per second, when using internal clocking. | |||
| OBJECT-TYPE | |||
| INTEGER | 1200..80000 | ||
| cdx6500mx25spStationAddress | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.5 | ||
| The station address on the multidrop line. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..2) | ||
| cdx6500mx25spPVCChannels | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.6 | ||
| Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..128 | ||
| cdx6500mx25spStartingPVC | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.7 | ||
| This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..255 | ||
| cdx6500mx25spSVCChannels | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.8 | ||
| Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..255 | ||
| cdx6500mx25spStartingSVC | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.9 | ||
| This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..255 | ||
| cdx6500mx25spPollTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.10 | ||
| Worst case delay for a slave to respond to a poll frame sent by the master, including modem turn around time, etc. Value in 10ths of second ( 30 = 3.0 seconds ). | |||
| OBJECT-TYPE | |||
| INTEGER | 1..255 | ||
| cdx6500mx25spTries | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.11 | ||
| Maximum number of attempts to complete a transmission. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..16 | ||
| cdx6500mx25spFrameWinSize | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.12 | ||
| Frame level window size must be set to the same value in devices at each end of the link. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..7 | ||
| cdx6500mx25spPacketWinSize | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.13 | ||
| Packet level window size must be set to the same value in devices at each end of the link. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..7 | ||
| cdx6500mx25spRestartTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.14 | ||
| Restart-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25spResetTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.15 | ||
| Reset-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25spCallTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.16 | ||
| Call-Request timeout timer in seconds. If timer expires, call is cleared. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..200 | ||
| cdx6500mx25spClearTimer | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.17 | ||
| Clear-Request timeout timer in seconds. If timer expires, request is sent again. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..255 | ||
| cdx6500mx25spMX25Options | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.18 | ||
| Select options on this MX.25 port as follows: NONE - no option specified. HOLD - hold calls over link restart. CUG - check closed user group; otherwise, CUG passes transparently. INL - inter-node link. Link goes to another 6500 device. INLA - set with INL option when an MX.25 link connection is to a 6500 node using 2.12.04 or earlier. DELAY - enable Delay and Path trace on this link (link must connected to Rel. 4.xx node) Any combination of the above specified by summing (e.g. HOLD+CUG+. . .). | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(3..22) | ||
| cdx6500mx25spRCDestination | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.19 | ||
| All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..32) | ||
| cdx6500mx25spCUG | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.20 | ||
| The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --) and separated by a comma. (e.g. 12,34,56,09,02,03 ). -- - No CUG Membership 00-99 - CUG Membership | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..23) | ||
| cdx6500mx25spBillingRecords | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.21 | ||
| This controls whether billing (accounting) records will be created for calls on this port. newvalOff - same functionality as 'off', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | off(0), on(1), newvalOff(50) | ||
| cdx6500mx25spPortControl | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.22 | ||
| Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(2..8) | ||
| cdx6500mx25spTXEncoding | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.23 | ||
| This is the data encoding used on the MX25 link. nrz - Non Return to Zero. nrzi - Non Return to Zero Inverted. newvalNrz - same functionality as 'nrz', new enumeration added for RFC1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | nrz(0), nrzi(1), newvalNrz(50) | ||
| cdx6500mx25spUpperQueue | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.24 | ||
| This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..15 | ||
| cdx6500mx25spLowerQueue | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.25 | ||
| This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..4 | ||
| cdx6500mx25spElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.26 | ||
| Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled | |||
| OBJECT-TYPE | |||
| INTEGER | v24(1), v35(2), v36(3), x21(4), none(5) | ||
| cdx6500mx25spV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.27 | ||
| Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal | |||
| OBJECT-TYPE | |||
| INTEGER | ri(1), tm(2) | ||
| cdx6500mx25spHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.28 | ||
| Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable | |||
| OBJECT-TYPE | |||
| INTEGER | none(1), xover(2) | ||
| cdx6500PCTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.3 | ||
| OBJECT IDENTIFIER | |||
| cdx6500SPCTMX25StationTable | 1.3.6.1.4.1.449.2.1.2.1.3.1 | ||
| All of the configuration parameters relevant to the MX.25 station table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500SPCTMX25StationEntry | |||
| cdx6500SPCTMX25StationEntry | 1.3.6.1.4.1.449.2.1.2.1.3.1.1 | ||
| A row of MX.25 station configuration parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500SPCTMX25StationEntry | |||
| cdx6500mx25sCfgPortNum | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.1 | ||
| MX25 Port Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25sCfgStationNum | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.2 | ||
| The number of the controller on the multidrop line. Also used for routing purposes. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..4 | ||
| cdx6500mx25sStationAddress | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.3 | ||
| The station address on the multidrop line. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..2) | ||
| cdx6500mx25sPVCChannels | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.4 | ||
| Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..128 | ||
| cdx6500mx25sStartingPVC | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.5 | ||
| This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..255 | ||
| cdx6500mx25sSVCChannels | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.6 | ||
| Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..255 | ||
| cdx6500mx25sStartingSVC | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.7 | ||
| This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..255 | ||
| cdx6500mx25sFrameWinSize | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.8 | ||
| Frame level window size must be set to the same value in devices at each end of the link. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..7 | ||
| cdx6500mx25sPacketWinSize | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.9 | ||
| Packet level window size must be set to the same value in devices at each end of the link. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..7 | ||
| cdx6500mx25sMX25Options | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.10 | ||
| Select options on this MX.25 port as follows: NONE - no option specified HOLD - hold calls over link restart CUG - check closed user group; otherwise, CUG passes transparently INL - inter-node link. Link goes to another 6500 device INLA - set with INL option when an MX.25 link connection is to a 6500 node using 2.12.04 or earlier Any combination of the above specified by summing (e.g. HOLD+CUG+. . .). | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(3..22) | ||
| cdx6500mx25sRCDestination | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.11 | ||
| All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..32) | ||
| cdx6500mx25sCUG | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.12 | ||
| The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --) and separated by a comma. (e.g. 12,34,56,09,02,03). -- - No CUG Membership 00-99 - CUG Membership | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..23) | ||
| cdx6500mx25sBillingRecords | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.13 | ||
| This controls whether billing (accounting) records will be created for calls on this port. newvalOff - same functionality as 'off', new enumeration added for RFc1155 compatibility. | |||
| OBJECT-TYPE | |||
| INTEGER | off(0), on(1), newvalOff(50) | ||
| cdx6500mx25sUpperQueue | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.14 | ||
| This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel. | |||
| OBJECT-TYPE | |||
| INTEGER | 5..15 | ||
| cdx6500mx25sLowerQueue | 1.3.6.1.4.1.449.2.1.2.1.3.1.1.15 | ||
| This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..4 | ||
| cdx6500Statistics | 1.3.6.1.4.1.449.2.1.3 | ||
| OBJECT IDENTIFIER | |||
| cdx6500StatProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1 | ||
| OBJECT IDENTIFIER | |||
| cdx6500PSTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.1 | ||
| OBJECT IDENTIFIER | |||
| cdx6500PPSTMX25PortTable | 1.3.6.1.4.1.449.2.1.3.1.1.4 | ||
| All of the statistics parameters relevant to the MX25 Port table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500PPSTMX25PortEntry | |||
| cdx6500PPSTMX25PortEntry | 1.3.6.1.4.1.449.2.1.3.1.1.4.1 | ||
| A row of MX25 Port statistics parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500PPSTMX25PortEntry | |||
| cdx6500mx25pStatsPortNum | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.1 | ||
| Number of the port. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25pPortStatus | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.2 | ||
| Status of this port : Up - Port is active. Down - Port Is inactive. Disabled - An operator has disabled the port. Busy Out - an operator has busied out the port. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(2..8) | ||
| cdx6500mx25pPortSpeed | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.3 | ||
| This is the speed of the port when Clock=Int; this is the detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext but clocking is not being received from attached device. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25pCharInTotal | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.4 | ||
| Number of characters received by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25pCharOutTotal | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.5 | ||
| Number of characters sent by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25pCharsInPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.6 | ||
| Summary of the characters being received over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25pCharsOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.7 | ||
| Summary of the characters being sent over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25pFrameInTotal | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.8 | ||
| Number of frames received by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25pFrameOutTotal | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.9 | ||
| Number of frames sent by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25pFramesInPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.10 | ||
| Summary of the frames being received over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25pFramesOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.1.4.1.11 | ||
| Summary of the frames being sent over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500PSTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.3 | ||
| OBJECT IDENTIFIER | |||
| cdx6500SPSTMX25StationTable | 1.3.6.1.4.1.449.2.1.3.1.3.1 | ||
| All of the statistics parameters relevant to the MX25 Station table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500SPSTMX25StationEntry | |||
| cdx6500SPSTMX25StationEntry | 1.3.6.1.4.1.449.2.1.3.1.3.1.1 | ||
| A row of MX25 Station statistics parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500SPSTMX25StationEntry | |||
| cdx6500mx25sStatsPortNum | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.1 | ||
| Number of the port. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25sStatsStationNum | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.2 | ||
| Station reference number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..4 | ||
| cdx6500mx25sStatsStnAddr | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.3 | ||
| Configured station address. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..2) | ||
| cdx6500mx25sCharInTotal | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.4 | ||
| Number of characters received by the port since the last node, port, or statistics reset | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25sCharOutTotal | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.5 | ||
| Number of characters sent by the port since the last node, port, or statistics reset | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25sCharsInPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.6 | ||
| Summary of the characters being received over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25sCharsOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.7 | ||
| Summary of the characters being sent over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25sFrameInTotal | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.8 | ||
| Number of frames received by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25sFrameOutTotal | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.9 | ||
| Number of frames sent by the port since the last node, port, or statistics reset. | |||
| OBJECT-TYPE | |||
| Counter | |||
| cdx6500mx25sFramesInPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.10 | ||
| Summary of the frames being received over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25sFramesOutPerSec | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.11 | ||
| Summary of the frames being sent over the port. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500mx25sCallCount | 1.3.6.1.4.1.449.2.1.3.1.3.1.1.12 | ||
| Current number of calls. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cdx6500Controls | 1.3.6.1.4.1.449.2.1.4 | ||
| OBJECT IDENTIFIER | |||
| cdx6500ContMX25 | 1.3.6.1.4.1.449.2.1.4.6 | ||
| OBJECT IDENTIFIER | |||
| cdx6500ContMX25StationTable | 1.3.6.1.4.1.449.2.1.4.6.1 | ||
| All of the control parameters relevant to the MX25 Station table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cdx6500ContMX25StationEntry | |||
| cdx6500ContMX25StationEntry | 1.3.6.1.4.1.449.2.1.4.6.1.1 | ||
| A row of MX25 Station Control parameters. | |||
| OBJECT-TYPE | |||
| Cdx6500ContMX25StationEntry | |||
| cdx6500mx25sContPortNum | 1.3.6.1.4.1.449.2.1.4.6.1.1.1 | ||
| MX25 Port Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..54 | ||
| cdx6500mx25sContStationNum | 1.3.6.1.4.1.449.2.1.4.6.1.1.2 | ||
| MX25 Station Number. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..4 | ||
| cdx6500mx25sContBootStation | 1.3.6.1.4.1.449.2.1.4.6.1.1.3 | ||
| Boots the specified MX25 station. boot - Boot Station. noBoot - Do not boot Station. | |||
| OBJECT-TYPE | |||
| INTEGER | boot(1), noBoot(2) | ||
| cdx6500mx25sContDisableStation | 1.3.6.1.4.1.449.2.1.4.6.1.1.4 | ||
| Disables the specified MX25 station. disable - Disable Station. noDisable - Do not disable Station. | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), noDisable(2) | ||
| cdx6500mx25sContEnableStation | 1.3.6.1.4.1.449.2.1.4.6.1.1.5 | ||
| Enables the specified MX25 station. enable - Enable Station. noEnable - Do not enable Station. | |||
| OBJECT-TYPE | |||
| INTEGER | enable(1), noEnable(2) | ||
| cdx6500mx25sContBusyOutStation | 1.3.6.1.4.1.449.2.1.4.6.1.1.6 | ||
| Busy outs the specified MX25 station. busyOut - Busyout Station. noBusyOut - Do not busyout Station. | |||
| OBJECT-TYPE | |||
| INTEGER | busyOut(1), noBusyOut(2) | ||
| cdx6500mx25sContResetStnStats | 1.3.6.1.4.1.449.2.1.4.6.1.1.7 | ||
| Busy outs the specified MX25 station. reset - Reset Station Statistics. noReset - Do not reset Station Statistics. | |||
| OBJECT-TYPE | |||
| INTEGER | reset(1), noReset(2) | ||
| DisplayString | |||
| OCTET STRING | |||
| Cdx6500PPCTMX25PortEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25pCfgPortNum | |||
| INTEGER as cdx6500mx25pSubType | |||
| Cdx6500PPCTMX25MPortEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25mpCfgPortNum | |||
| INTEGER as cdx6500mx25mpSubType | |||
| INTEGER as cdx6500mx25mpClockSource | |||
| INTEGER as cdx6500mx25mpClockSpeed | |||
| INTEGER as cdx6500mx25mpStationCnt | |||
| INTEGER as cdx6500mx25mpPollTimer | |||
| INTEGER as cdx6500mx25mpPollPeriod | |||
| INTEGER as cdx6500mx25mpTries | |||
| INTEGER as cdx6500mx25mpRestartTimer | |||
| INTEGER as cdx6500mx25mpResetTimer | |||
| INTEGER as cdx6500mx25mpCallTimer | |||
| INTEGER as cdx6500mx25mpClearTimer | |||
| DisplayString as cdx6500mx25mpPortControl | |||
| INTEGER as cdx6500mx25mpTXEncoding | |||
| INTEGER as cdx6500mx25mpElectricalInterfaceType | |||
| INTEGER as cdx6500mx25mpV24ElectricalInterfaceOption | |||
| INTEGER as cdx6500mx25mpHighSpeedElectricalInterfaceOption | |||
| Cdx6500PPCTMX25SPortEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25spCfgPortNum | |||
| INTEGER as cdx6500mx25spSubType | |||
| INTEGER as cdx6500mx25spClockSource | |||
| INTEGER as cdx6500mx25spClockSpeed | |||
| DisplayString as cdx6500mx25spStationAddress | |||
| INTEGER as cdx6500mx25spPVCChannels | |||
| INTEGER as cdx6500mx25spStartingPVC | |||
| INTEGER as cdx6500mx25spSVCChannels | |||
| INTEGER as cdx6500mx25spStartingSVC | |||
| INTEGER as cdx6500mx25spPollTimer | |||
| INTEGER as cdx6500mx25spTries | |||
| INTEGER as cdx6500mx25spFrameWinSize | |||
| INTEGER as cdx6500mx25spPacketWinSize | |||
| INTEGER as cdx6500mx25spRestartTimer | |||
| INTEGER as cdx6500mx25spResetTimer | |||
| INTEGER as cdx6500mx25spCallTimer | |||
| INTEGER as cdx6500mx25spClearTimer | |||
| DisplayString as cdx6500mx25spMX25Options | |||
| DisplayString as cdx6500mx25spRCDestination | |||
| DisplayString as cdx6500mx25spCUG | |||
| INTEGER as cdx6500mx25spBillingRecords | |||
| DisplayString as cdx6500mx25spPortControl | |||
| INTEGER as cdx6500mx25spTXEncoding | |||
| INTEGER as cdx6500mx25spUpperQueue | |||
| INTEGER as cdx6500mx25spLowerQueue | |||
| INTEGER as cdx6500mx25spElectricalInterfaceType | |||
| INTEGER as cdx6500mx25spV24ElectricalInterfaceOption | |||
| INTEGER as cdx6500mx25spHighSpeedElectricalInterfaceOption | |||
| Cdx6500PPSTMX25PortEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25pStatsPortNum | |||
| DisplayString as cdx6500mx25pPortStatus | |||
| INTEGER as cdx6500mx25pPortSpeed | |||
| Counter as cdx6500mx25pCharInTotal | |||
| Counter as cdx6500mx25pCharOutTotal | |||
| INTEGER as cdx6500mx25pCharsInPerSec | |||
| INTEGER as cdx6500mx25pCharsOutPerSec | |||
| Counter as cdx6500mx25pFrameInTotal | |||
| Counter as cdx6500mx25pFrameOutTotal | |||
| INTEGER as cdx6500mx25pFramesInPerSec | |||
| INTEGER as cdx6500mx25pFramesOutPerSec | |||
| Cdx6500SPCTMX25StationEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25sCfgPortNum | |||
| INTEGER as cdx6500mx25sCfgStationNum | |||
| DisplayString as cdx6500mx25sStationAddress | |||
| INTEGER as cdx6500mx25sPVCChannels | |||
| INTEGER as cdx6500mx25sStartingPVC | |||
| INTEGER as cdx6500mx25sSVCChannels | |||
| INTEGER as cdx6500mx25sStartingSVC | |||
| INTEGER as cdx6500mx25sFrameWinSize | |||
| INTEGER as cdx6500mx25sPacketWinSize | |||
| DisplayString as cdx6500mx25sMX25Options | |||
| DisplayString as cdx6500mx25sRCDestination | |||
| DisplayString as cdx6500mx25sCUG | |||
| INTEGER as cdx6500mx25sBillingRecords | |||
| INTEGER as cdx6500mx25sUpperQueue | |||
| INTEGER as cdx6500mx25sLowerQueue | |||
| Cdx6500SPSTMX25StationEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25sStatsPortNum | |||
| INTEGER as cdx6500mx25sStatsStationNum | |||
| DisplayString as cdx6500mx25sStatsStnAddr | |||
| Counter as cdx6500mx25sCharInTotal | |||
| Counter as cdx6500mx25sCharOutTotal | |||
| INTEGER as cdx6500mx25sCharsInPerSec | |||
| INTEGER as cdx6500mx25sCharsOutPerSec | |||
| Counter as cdx6500mx25sFrameInTotal | |||
| Counter as cdx6500mx25sFrameOutTotal | |||
| INTEGER as cdx6500mx25sFramesInPerSec | |||
| INTEGER as cdx6500mx25sFramesOutPerSec | |||
| INTEGER as cdx6500mx25sCallCount | |||
| Cdx6500ContMX25StationEntry | |||
| SEQUENCE | |||
| INTEGER as cdx6500mx25sContPortNum | |||
| INTEGER as cdx6500mx25sContStationNum | |||
| INTEGER as cdx6500mx25sContBootStation | |||
| INTEGER as cdx6500mx25sContDisableStation | |||
| INTEGER as cdx6500mx25sContEnableStation | |||
| INTEGER as cdx6500mx25sContBusyOutStation | |||
| INTEGER as cdx6500mx25sContResetStnStats | |||