NETBOTZ-MIB

File: NETBOTZ-MIB.mib (130674 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC1155-SMI
RFC-1215

Imported symbols

OBJECT-TYPE DisplayString enterprises
TRAP-TYPE TimeTicks IpAddress

Defined Objects

netBotz 1.3.6.1.4.1.5528
OBJECT IDENTIFIER    

netBotz-reg 1.3.6.1.4.1.5528.10
OBJECT IDENTIFIER    

netBotz-generic 1.3.6.1.4.1.5528.20
OBJECT IDENTIFIER    

netBotz-products 1.3.6.1.4.1.5528.30
OBJECT IDENTIFIER    

netBotz-prd-bot 1.3.6.1.4.1.5528.30.10
OBJECT IDENTIFIER    

netBotz-prd-bot-temp 1.3.6.1.4.1.5528.30.10.1
The reading of the temperature probe, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-low-trap 1.3.6.1.4.1.5528.30.10.1
NetBotz Low Trap. This trap indicates that a lower limit has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity 1.3.6.1.4.1.5528.30.10.2
The reading of the humidity probe, in percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-high-trap 1.3.6.1.4.1.5528.30.10.2
NetBotz High Trap. This trap indicates that an upper limit has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow 1.3.6.1.4.1.5528.30.10.3
The reading of the airflow probe. Each unit represents approximately 40 feet/minute or 13 meters/minute of airflow velocity.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-clear 1.3.6.1.4.1.5528.30.10.3
NetBotz Cleared Trap. The trap has been cleared because the value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio 1.3.6.1.4.1.5528.30.10.4
The reading of the audio alarm probe on/off.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-offline-trap 1.3.6.1.4.1.5528.30.10.4
NetBotz Device Offline Trap. This trap indicates that a device or function has been determined to be offline.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-doorajar 1.3.6.1.4.1.5528.30.10.5
The reading of the door switch probe open(0) or closed(1).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-online-trap 1.3.6.1.4.1.5528.30.10.5
NetBotz Device Online Trap. This trap indicates that a device or function has been determined to be online.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temp-min 1.3.6.1.4.1.5528.30.10.6
The temperature probe minimum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-temp-max 1.3.6.1.4.1.5528.30.10.7
The temperature probe maximum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-humidity-min 1.3.6.1.4.1.5528.30.10.8
The humidity probe minimum, from 10 to 90 percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-humidity-max 1.3.6.1.4.1.5528.30.10.9
The humidity probe maximum, from 10 to 90 percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-airflow-mins 1.3.6.1.4.1.5528.30.10.10
Minutes without airflow before alarm set.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-secs 1.3.6.1.4.1.5528.30.10.11
Seconds of alarm audio before alarm set.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-temp-enabled 1.3.6.1.4.1.5528.30.10.12
Temperature probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-hum-enabled 1.3.6.1.4.1.5528.30.10.13
Humidity probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-air-enabled 1.3.6.1.4.1.5528.30.10.14
Airflow probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-enabled 1.3.6.1.4.1.5528.30.10.15
Audio probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-switch-state 1.3.6.1.4.1.5528.30.10.16
Switch state setting. The state controls which condition of the door switch indicates an alarm. If set to 0, alarm is set when the switch is closed. If set to 1, alarm is set when the switch is open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-switch-enabled 1.3.6.1.4.1.5528.30.10.17
Door switch enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-level 1.3.6.1.4.1.5528.30.10.18
Audio level setting. This is the relative audio level, from 0-11, above which an alarm will be sent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-doorpic-delay 1.3.6.1.4.1.5528.30.10.19
Number of seconds between door alert and first picture.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-index 1.3.6.1.4.1.5528.30.10.20
The crawler ID of the last trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-address 1.3.6.1.4.1.5528.30.10.21
The IP address of the last trap.
OBJECT-TYPE    
  IpAddress  

netBotz-prd-bot-trap-oid 1.3.6.1.4.1.5528.30.10.22
The object id of the last trap.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

netBotz-prd-bot-trap-value 1.3.6.1.4.1.5528.30.10.23
The value of the last object trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-date 1.3.6.1.4.1.5528.30.10.24
The date and time of a specific trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-refresh 1.3.6.1.4.1.5528.30.10.26
Rate of web page refresh, in seconds. This must be greater than 5 seconds.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-airflow-level 1.3.6.1.4.1.5528.30.10.27
Airflow alert level. This is the relative level of airflow below which an alarm will be sent. The range is 1-11. Each unit is approximately 40 feet/second or 13 meters/second of airflow velocity.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-doorpic-count 1.3.6.1.4.1.5528.30.10.28
Number of pictures to take when door activated. These pictures will be sent as attachments to the door alert e-mail. The range is from 0 to 5 pictures.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1 1.3.6.1.4.1.5528.30.10.29
The reading of the first amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-enabled 1.3.6.1.4.1.5528.30.10.30
Amperage[1] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-min 1.3.6.1.4.1.5528.30.10.31
The amperage[1] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-max 1.3.6.1.4.1.5528.30.10.32
The amperage[1] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2 1.3.6.1.4.1.5528.30.10.34
The reading of the second amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-enabled 1.3.6.1.4.1.5528.30.10.35
Amperage[2] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-min 1.3.6.1.4.1.5528.30.10.36
The amperage[2] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-max 1.3.6.1.4.1.5528.30.10.37
The amperage[2] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3 1.3.6.1.4.1.5528.30.10.39
The reading of the third amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-enabled 1.3.6.1.4.1.5528.30.10.40
Amperage[3] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-min 1.3.6.1.4.1.5528.30.10.41
The amperage[3] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-max 1.3.6.1.4.1.5528.30.10.42
The amperage[3] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total 1.3.6.1.4.1.5528.30.10.44
The total of the readings of all amperage probes, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-enabled 1.3.6.1.4.1.5528.30.10.45
Total amperage alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-min 1.3.6.1.4.1.5528.30.10.46
The total amperage minimum, from 0 to 90000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-max 1.3.6.1.4.1.5528.30.10.47
The total amperage maximum, from 0 to 90000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-support-enabled 1.3.6.1.4.1.5528.30.10.48
Total Amperage Support enabled(Y) or disabled(N).
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-amps1-uV-per-10mA 1.3.6.1.4.1.5528.30.10.49
The scaling factor used for the first amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-uV-per-10mA 1.3.6.1.4.1.5528.30.10.50
The scaling factor used for the second amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-uV-per-mA 1.3.6.1.4.1.5528.30.10.51
The scaling factor used for the third amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-max-range 1.3.6.1.4.1.5528.30.10.52
The maximum RMS milliamps measureable by the first Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-max-range 1.3.6.1.4.1.5528.30.10.53
The maximum RMS milliamps measureable by the second Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-max-range 1.3.6.1.4.1.5528.30.10.54
The maximum RMS milliamps measureable by the third Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4 1.3.6.1.4.1.5528.30.10.55
The reading of the fourth amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-enabled 1.3.6.1.4.1.5528.30.10.56
Amperage[4] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-min 1.3.6.1.4.1.5528.30.10.57
The amperage[4] probe minimum, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-max 1.3.6.1.4.1.5528.30.10.58
The amperage[4] probe maximum, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-uV-per-10mA 1.3.6.1.4.1.5528.30.10.60
The scaling factor used for the fourth amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-max-range 1.3.6.1.4.1.5528.30.10.61
The maximum RMS milliamps measureable by the fourth Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1 1.3.6.1.4.1.5528.30.10.62
The reading of the external temperature probe on port 1, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2 1.3.6.1.4.1.5528.30.10.63
The reading of the external temperature probe on port 2, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3 1.3.6.1.4.1.5528.30.10.64
The reading of the external temperature probe on port 3, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-enabled 1.3.6.1.4.1.5528.30.10.66
External temperature probe on port 1 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-min 1.3.6.1.4.1.5528.30.10.67
The external temperature probe on port 1 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-max 1.3.6.1.4.1.5528.30.10.68
The external temperature probe on port 1 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-enabled 1.3.6.1.4.1.5528.30.10.69
External temperature probe on port 2 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-min 1.3.6.1.4.1.5528.30.10.70
The external temperature probe on port 2 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-max 1.3.6.1.4.1.5528.30.10.71
The external temperature probe on port 2 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-enabled 1.3.6.1.4.1.5528.30.10.72
External temperature probe on port 3 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-min 1.3.6.1.4.1.5528.30.10.73
The external temperature probe on port 3 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-max 1.3.6.1.4.1.5528.30.10.74
The external temperature probe on port 3 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.78
The scaling factor used for the external temperature probe on port 1 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.79
The offset used for the external temperature probe on port 1 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-min-range 1.3.6.1.4.1.5528.30.10.80
The minimum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-max-range 1.3.6.1.4.1.5528.30.10.81
The maximum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.82
The scaling factor used for the external temperature probe on port 2 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.83
The offset used for the external temperature probe on port 2 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-min-range 1.3.6.1.4.1.5528.30.10.84
The minimum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-max-range 1.3.6.1.4.1.5528.30.10.85
The maximum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.86
The scaling factor used for the external temperature probe on port 3 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.87
The offset used for the external temperature probe on port 3 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-min-range 1.3.6.1.4.1.5528.30.10.88
The minimum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-max-range 1.3.6.1.4.1.5528.30.10.89
The maximum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-port1-module-id 1.3.6.1.4.1.5528.30.10.94
The module ID of the sensor module installed on port 1. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port1-module-type 1.3.6.1.4.1.5528.30.10.95
The type of sensor module installed on port 1. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port2-module-id 1.3.6.1.4.1.5528.30.10.96
The module ID of the sensor module installed on port 2. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port2-module-type 1.3.6.1.4.1.5528.30.10.97
The type of sensor module installed on port 2. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port3-module-id 1.3.6.1.4.1.5528.30.10.98
The module ID of the sensor module installed on port 3. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port3-module-type 1.3.6.1.4.1.5528.30.10.99
The type of sensor module installed on port 3. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port4-module-id 1.3.6.1.4.1.5528.30.10.100
The module ID of the sensor module installed on port 4. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port4-module-type 1.3.6.1.4.1.5528.30.10.101
The type of sensor module installed on port 4. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-amp1-total-amp-seconds 1.3.6.1.4.1.5528.30.10.102
The accumulated total of amp-seconds on the AmpDetect on port 1.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp1-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.103
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 1. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp2-total-amp-seconds 1.3.6.1.4.1.5528.30.10.104
The accumulated total of amp-seconds on the AmpDetect on port 2.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp2-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.105
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 2. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp3-total-amp-seconds 1.3.6.1.4.1.5528.30.10.106
The accumulated total of amp-seconds on the AmpDetect on port 3.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp3-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.107
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 3. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp4-total-amp-seconds 1.3.6.1.4.1.5528.30.10.108
The accumulated total of amp-seconds on the AmpDetect on port 4.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp4-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.109
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 4. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amptotal-total-amp-seconds 1.3.6.1.4.1.5528.30.10.110
The accumulated total of amp-seconds on the total of all AmpDetects.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amptotal-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.111
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds for all AmpDetects. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1 1.3.6.1.4.1.5528.30.10.112
The current value of the external dry contact sensor on Ext1: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2 1.3.6.1.4.1.5528.30.10.113
The current value of the external dry contact sensor on Ext2: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3 1.3.6.1.4.1.5528.30.10.114
The current value of the external dry contact sensor on Ext3: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4 1.3.6.1.4.1.5528.30.10.115
The current value of the external dry contact sensor on Ext4: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-alarm-value 1.3.6.1.4.1.5528.30.10.116
The value to generate alarms on for the external dry contact sensor on Ext1: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-enabled 1.3.6.1.4.1.5528.30.10.117
External dry contact sensor on Ext1 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-alarm-value 1.3.6.1.4.1.5528.30.10.118
The value to generate alarms on for the external dry contact sensor on Ext2: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-enabled 1.3.6.1.4.1.5528.30.10.119
External dry contact sensor on Ext2 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-alarm-value 1.3.6.1.4.1.5528.30.10.120
The value to generate alarms on for the external dry contact sensor on Ext3: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-enabled 1.3.6.1.4.1.5528.30.10.121
External dry contact sensor on Ext3 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-alarm-value 1.3.6.1.4.1.5528.30.10.122
The value to generate alarms on for the external dry contact sensor on Ext4: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-enabled 1.3.6.1.4.1.5528.30.10.123
External dry contact sensor on Ext4 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-label 1.3.6.1.4.1.5528.30.10.124
The sensor name/label for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-open-label 1.3.6.1.4.1.5528.30.10.125
The sensor name/label for the open(0) state for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-closed-label 1.3.6.1.4.1.5528.30.10.126
The sensor name/label for the closed(0) state for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-open-to-close-millis 1.3.6.1.4.1.5528.30.10.127
The minimum number of milliseconds that the dry contact sensor on Ext1 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-close-to-open-millis 1.3.6.1.4.1.5528.30.10.128
The minimum number of milliseconds that the dry contact sensor on Ext1 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-response 1.3.6.1.4.1.5528.30.10.129
The type of alert response for the dry contact sensor on Ext1: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-label 1.3.6.1.4.1.5528.30.10.130
The sensor name/label for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-open-label 1.3.6.1.4.1.5528.30.10.131
The sensor name/label for the open(0) state for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-closed-label 1.3.6.1.4.1.5528.30.10.132
The sensor name/label for the closed(0) state for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-open-to-close-millis 1.3.6.1.4.1.5528.30.10.133
The minimum number of milliseconds that the dry contact sensor on Ext2 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-close-to-open-millis 1.3.6.1.4.1.5528.30.10.134
The minimum number of milliseconds that the dry contact sensor on Ext2 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-response 1.3.6.1.4.1.5528.30.10.135
The type of alert response for the dry contact sensor on Ext2: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-label 1.3.6.1.4.1.5528.30.10.136
The sensor name/label for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-open-label 1.3.6.1.4.1.5528.30.10.137
The sensor name/label for the open(0) state for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-closed-label 1.3.6.1.4.1.5528.30.10.138
The sensor name/label for the closed(0) state for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-open-to-close-millis 1.3.6.1.4.1.5528.30.10.139
The minimum number of milliseconds that the dry contact sensor on Ext3 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-close-to-open-millis 1.3.6.1.4.1.5528.30.10.140
The minimum number of milliseconds that the dry contact sensor on Ext3 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-response 1.3.6.1.4.1.5528.30.10.141
The type of alert response for the dry contact sensor on Ext3: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-cam-motion 1.3.6.1.4.1.5528.30.10.148
The current motion reading for the camera motion sensor (0=none, 1=motion detected)
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-cam-motion-enabled 1.3.6.1.4.1.5528.30.10.149
Camera motion sensor alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-cam-motion-sensitivity 1.3.6.1.4.1.5528.30.10.150
Camera motion sensor sensitivity: 1=max, 11=min, 0=disabled.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-cam-motion-delay 1.3.6.1.4.1.5528.30.10.151
Camera motion sensor delay. This is the minimum number of milliseconds of detected motion required before the alarm is triggered.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-camera-event-autocycle 1.3.6.1.4.1.5528.30.10.152
Enables (1) or disables (0) the option to have the camera-based responses to alarm conditions automatically cycle as long as the condition persists.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-num-pix-before-alarm 1.3.6.1.4.1.5528.30.10.153
Controls the number of pictures to be captured before any triggered alarm.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-delay-before-event-pix 1.3.6.1.4.1.5528.30.10.154
Controls the number of milliseconds before the first picture is captured after any triggered alarm.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-delay-between-event-pix 1.3.6.1.4.1.5528.30.10.155
Controls the number of milliseconds between pictures captured after any triggered alarm.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crawlers 1.3.6.1.4.1.5528.30.20
OBJECT IDENTIFIER    

netbotz-crawlers 1.3.6.1.4.1.5528.30.20.5528
OBJECT IDENTIFIER    

netBotz-prd-crl-mib2 1.3.6.1.4.1.5528.30.20.5528.1
OBJECT IDENTIFIER    

netBotz-prd-crl-mib2-ping 1.3.6.1.4.1.5528.30.20.5528.1.3
NetBotz device ping. This object indicates the status of a ping on a device monitored by a NetBotz device.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-ping-offline-trap 1.3.6.1.4.1.5528.30.20.5528.1.3.4
NetBotz Ping Trap. This trap indicates that replies to a set of pings were not received from a monitored IP address.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-ping-online-trap 1.3.6.1.4.1.5528.30.20.5528.1.3.5
NetBotz Ping Trap. This trap indicates that replies to a set of pings were received from a monitored IP address after a period when no replies had been received.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-mib2-uptime 1.3.6.1.4.1.5528.30.20.5528.1.8
The uptime of a device monitored by a NetBotz device.
OBJECT-TYPE    
  TimeTicks  

netBotz-prd-crl-uptime-online-trap 1.3.6.1.4.1.5528.30.20.5528.1.8.5
NetBotz Uptime Trap. This trap indicates that a device restart has been detected due to the uptime of the device being reported as less than the previously reported reading.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-mib2-snmpstatus 1.3.6.1.4.1.5528.30.20.5528.1.9
The SNMP status of a device monitored by a NetBotz device.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-crl-snmp-offline-trap 1.3.6.1.4.1.5528.30.20.5528.1.9.4
NetBotz SNMP Offline Trap. This trap indicates that an SNMP request was not possible on an IP address.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-snmp-online-trap 1.3.6.1.4.1.5528.30.20.5528.1.9.5
NetBotz SNMP Online Trap. This trap indicates that an SNMP request succeeded on an IP address where it had previously failed.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-mib2if 1.3.6.1.4.1.5528.30.20.5528.2
OBJECT IDENTIFIER    

netBotz-prd-crl-mib2if-opstatus 1.3.6.1.4.1.5528.30.20.5528.2.6
The operational status of a device monitored by a NetBotz device.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-opstatus-mismatch-trap 1.3.6.1.4.1.5528.30.20.5528.2.6.1
NetBotz Interface Status Mismatch Trap. This trap indicates that the operational status of a device interface does not match the administrative status.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-opstatus-match-trap 1.3.6.1.4.1.5528.30.20.5528.2.6.2
NetBotz Interface Status Match Trap. This trap indicates that the operational status of a device interface now matches the administrative status. This trap indicates a transition from a state in which the administrative and operational status did not match.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crl-opstatus-offline-trap 1.3.6.1.4.1.5528.30.20.5528.2.6.4
NetBotz Interface Offline Trap. This trap indicates that an interface on a device did not respond to an SNMP query on the ifAdminStatus or ifOperStatus objects.
TRAP-TYPE    
  netBotz-prd-crl-trap-index  
  netBotz-prd-crl-trap-address  
  netBotz-prd-crl-trap-oid  
  netBotz-prd-crl-trap-botoid  
  netBotz-prd-crl-trap-value  
  netBotz-prd-crl-trap-date  
  netBotz-prd-crl-trap-attrib  
  netBotz-prd-crl-trap-desc  
  netBotz-ismetric  

netBotz-prd-crltrap 1.3.6.1.4.1.5528.30.21
OBJECT IDENTIFIER    

netBotz-prd-crl-trap-index 1.3.6.1.4.1.5528.30.21.20
The ID of the crawler which sent the last trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-trap-address 1.3.6.1.4.1.5528.30.21.21
The IP address of the last trap.
OBJECT-TYPE    
  IpAddress  

netBotz-prd-crl-trap-oid 1.3.6.1.4.1.5528.30.21.22
The object id of the attribute on the target device which is the concern of the last trap.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

netBotz-prd-crl-trap-botoid 1.3.6.1.4.1.5528.30.21.23
The object id of the attribute on the NetBotz device which is the concern of the last trap.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

netBotz-prd-crl-trap-value 1.3.6.1.4.1.5528.30.21.24
The value of the attribute associated with the last trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-trap-date 1.3.6.1.4.1.5528.30.21.25
The date and time of a specific trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-trap-attrib 1.3.6.1.4.1.5528.30.21.26
The identification number of the attribute in error
OBJECT-TYPE    
  INTEGER  

netBotz-prd-crl-trap-desc 1.3.6.1.4.1.5528.30.21.27
Description or name of the attribute in error
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-traps 1.3.6.1.4.1.5528.30.100
OBJECT IDENTIFIER    

netBotz-prd-bot-temperature-traps 1.3.6.1.4.1.5528.30.100.1
OBJECT IDENTIFIER    

netBotz-prd-bot-temperature-low-trap 1.3.6.1.4.1.5528.30.100.1.1
NetBotz Temperature Low Trap. This trap indicates that the lower limit for temperature has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temperature-high-trap 1.3.6.1.4.1.5528.30.100.1.2
NetBotz Temperature High Trap. This trap indicates that the upper limit for temperature has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temperature-trap-clear 1.3.6.1.4.1.5528.30.100.1.3
NetBotz Temperature Cleared Trap. The trap has been cleared because the temperature value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-traps 1.3.6.1.4.1.5528.30.100.2
OBJECT IDENTIFIER    

netBotz-prd-bot-humidity-low-trap 1.3.6.1.4.1.5528.30.100.2.1
NetBotz Humidity Low Trap. This trap indicates that the lower limit for humidity has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-high-trap 1.3.6.1.4.1.5528.30.100.2.2
NetBotz Humidity High Trap. This trap indicates that the upper limit for humidity has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-trap-clear 1.3.6.1.4.1.5528.30.100.2.3
NetBotz Humidity Cleared Trap. The trap has been cleared because the humidity value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow-traps 1.3.6.1.4.1.5528.30.100.3
OBJECT IDENTIFIER    

netBotz-prd-bot-airflow-low-trap 1.3.6.1.4.1.5528.30.100.3.1
NetBotz Airflow Low Trap. This trap indicates that the lower limit for airflow has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow-trap-clear 1.3.6.1.4.1.5528.30.100.3.3
NetBotz Airflow Cleared Trap. The trap has been cleared because the airflow value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio-traps 1.3.6.1.4.1.5528.30.100.4
OBJECT IDENTIFIER    

netBotz-prd-bot-audio-high-trap 1.3.6.1.4.1.5528.30.100.4.2
NetBotz Audio High Trap. This trap indicates that the upper limit for audio has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio-trap-clear 1.3.6.1.4.1.5528.30.100.4.3
NetBotz Audio Cleared Trap. The trap has been cleared because the audio value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-door-traps 1.3.6.1.4.1.5528.30.100.5
OBJECT IDENTIFIER    

netBotz-prd-bot-door-trap-tripped 1.3.6.1.4.1.5528.30.100.5.2
NetBotz Door Sensor Tripped Trap. This trap indicates that the door sensor has been triggered (i.e. opened, if the thresdhold has been set to trip on open, closed if otherwise).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-door-trap-clear 1.3.6.1.4.1.5528.30.100.5.3
NetBotz Door Cleared Trap. The trap has been cleared because the door sensor has returned to normal (i.e. been closed, if the threshold has been set to trip on open).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-traps 1.3.6.1.4.1.5528.30.100.6
OBJECT IDENTIFIER    

netBotz-prd-bot-amp1-low-trap 1.3.6.1.4.1.5528.30.100.6.1
NetBotz Amp1 Low Trap. This trap indicates that the lower limit for the first amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-high-trap 1.3.6.1.4.1.5528.30.100.6.2
NetBotz Amp1 High Trap. This trap indicates that the upper limit for the first amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-trap-clear 1.3.6.1.4.1.5528.30.100.6.3
NetBotz Amp1 Cleared Trap. The trap has been cleared because the first amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-sensor-unplugged 1.3.6.1.4.1.5528.30.100.6.6
NetBotz Amp 1 Sensor Unplugged Trap. The sensor for the first AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-sensor-replugged 1.3.6.1.4.1.5528.30.100.6.7
NetBotz Amp 1 Sensor Replugged Trap. The sensor for the first AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-traps 1.3.6.1.4.1.5528.30.100.7
OBJECT IDENTIFIER    

netBotz-prd-bot-amp2-low-trap 1.3.6.1.4.1.5528.30.100.7.1
NetBotz Amp2 Low Trap. This trap indicates that the lower limit for the second amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-high-trap 1.3.6.1.4.1.5528.30.100.7.2
NetBotz Amp2 High Trap. This trap indicates that the upper limit for the second amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-trap-clear 1.3.6.1.4.1.5528.30.100.7.3
NetBotz Amp2 Cleared Trap. The trap has been cleared because the second amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-sensor-unplugged 1.3.6.1.4.1.5528.30.100.7.6
NetBotz Amp 2 Sensor Unplugged Trap. The sensor for the second AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-sensor-replugged 1.3.6.1.4.1.5528.30.100.7.7
NetBotz Amp 2 Sensor Replugged Trap. The sensor for the second AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-traps 1.3.6.1.4.1.5528.30.100.8
OBJECT IDENTIFIER    

netBotz-prd-bot-amp3-low-trap 1.3.6.1.4.1.5528.30.100.8.1
NetBotz Amp3 Low Trap. This trap indicates that the lower limit for the third amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-high-trap 1.3.6.1.4.1.5528.30.100.8.2
NetBotz Amp3 High Trap. This trap indicates that the upper limit for the third amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-trap-clear 1.3.6.1.4.1.5528.30.100.8.3
NetBotz Amp3 Cleared Trap. The trap has been cleared because the third amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-sensor-unplugged 1.3.6.1.4.1.5528.30.100.8.6
NetBotz Amp 3 Sensor Unplugged Trap. The sensor for the third AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-sensor-replugged 1.3.6.1.4.1.5528.30.100.8.7
NetBotz Amp 3 Sensor Replugged Trap. The sensor for the third AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-traps 1.3.6.1.4.1.5528.30.100.9
OBJECT IDENTIFIER    

netBotz-prd-bot-amp4-low-trap 1.3.6.1.4.1.5528.30.100.9.1
NetBotz Amp4 Low Trap. This trap indicates that the lower limit for the fourth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-high-trap 1.3.6.1.4.1.5528.30.100.9.2
NetBotz Amp4 High Trap. This trap indicates that the upper limit for the fourth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-trap-clear 1.3.6.1.4.1.5528.30.100.9.3
NetBotz Amp4 Cleared Trap. The trap has been cleared because the fourth amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-sensor-unplugged 1.3.6.1.4.1.5528.30.100.9.6
NetBotz Amp 4 Sensor Unplugged Trap. The sensor for the fourth AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-sensor-replugged 1.3.6.1.4.1.5528.30.100.9.7
NetBotz Amp 4 Sensor Replugged Trap. The sensor for the fourth AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-traps 1.3.6.1.4.1.5528.30.100.10
OBJECT IDENTIFIER    

netBotz-prd-bot-amp-total-low-trap 1.3.6.1.4.1.5528.30.100.10.1
NetBotz Total Amps Low Trap. This trap indicates that the lower limit for the total amperage has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-high-trap 1.3.6.1.4.1.5528.30.100.10.2
NetBotz Total Amps High Trap. This trap indicates that the upper limit for the total amperage has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-trap-clear 1.3.6.1.4.1.5528.30.100.10.3
NetBotz Total Amps Cleared Trap. The trap has been cleared because the total amperage value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-traps 1.3.6.1.4.1.5528.30.100.11
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp1-low-trap 1.3.6.1.4.1.5528.30.100.11.1
NetBotz External Temperature 1 Low Trap. This trap indicates that the lower limit for external temperature probe on port 1 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-high-trap 1.3.6.1.4.1.5528.30.100.11.2
NetBotz External Temperature 1 High Trap. This trap indicates that the upper limit for external temperature probe on port 1 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-trap-clear 1.3.6.1.4.1.5528.30.100.11.3
NetBotz External Temperature 1 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 1 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-sensor-unplugged 1.3.6.1.4.1.5528.30.100.11.6
NetBotz External Temperature 1 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-sensor-replugged 1.3.6.1.4.1.5528.30.100.11.7
NetBotz External Temperature 1 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-traps 1.3.6.1.4.1.5528.30.100.12
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp2-low-trap 1.3.6.1.4.1.5528.30.100.12.1
NetBotz External Temperature 2 Low Trap. This trap indicates that the lower limit for external temperature probe on port 2 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-high-trap 1.3.6.1.4.1.5528.30.100.12.2
NetBotz External Temperature 2 High Trap. This trap indicates that the upper limit for external temperature probe on port 2 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-trap-clear 1.3.6.1.4.1.5528.30.100.12.3
NetBotz External Temperature 2 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 2 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-sensor-unplugged 1.3.6.1.4.1.5528.30.100.12.6
NetBotz External Temperature 2 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-sensor-replugged 1.3.6.1.4.1.5528.30.100.12.7
NetBotz External Temperature 2 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-traps 1.3.6.1.4.1.5528.30.100.13
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp3-low-trap 1.3.6.1.4.1.5528.30.100.13.1
NetBotz External Temperature 3 Low Trap. This trap indicates that the lower limit for external temperature probe on port 3 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-high-trap 1.3.6.1.4.1.5528.30.100.13.2
NetBotz External Temperature 3 High Trap. This trap indicates that the upper limit for external temperature probe on port 3 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-trap-clear 1.3.6.1.4.1.5528.30.100.13.3
NetBotz External Temperature 3 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 3 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-sensor-unplugged 1.3.6.1.4.1.5528.30.100.13.6
NetBotz External Temperature 3 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-sensor-replugged 1.3.6.1.4.1.5528.30.100.13.7
NetBotz External Temperature 3 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-traps 1.3.6.1.4.1.5528.30.100.14
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp4-low-trap 1.3.6.1.4.1.5528.30.100.14.1
NetBotz External Temperature 4 Low Trap. This trap indicates that the lower limit for external temperature probe on port 4 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-high-trap 1.3.6.1.4.1.5528.30.100.14.2
NetBotz External Temperature 4 High Trap. This trap indicates that the upper limit for external temperature probe on port 4 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-trap-clear 1.3.6.1.4.1.5528.30.100.14.3
NetBotz External Temperature 4 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 4 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-sensor-unplugged 1.3.6.1.4.1.5528.30.100.14.6
NetBotz External Temperature 4 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-sensor-replugged 1.3.6.1.4.1.5528.30.100.14.7
NetBotz External Temperature 4 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry1-traps 1.3.6.1.4.1.5528.30.100.15
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry1-triggered-trap 1.3.6.1.4.1.5528.30.100.15.2
NetBotz External Dry Contact 1 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext1 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry1-trap-clear 1.3.6.1.4.1.5528.30.100.15.3
NetBotz External Dry Contact 1 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext1 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry2-traps 1.3.6.1.4.1.5528.30.100.16
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry2-triggered-trap 1.3.6.1.4.1.5528.30.100.16.2
NetBotz External Dry Contact 2 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext2 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry2-trap-clear 1.3.6.1.4.1.5528.30.100.16.3
NetBotz External Dry Contact 2 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext2 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry3-traps 1.3.6.1.4.1.5528.30.100.17
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry3-triggered-trap 1.3.6.1.4.1.5528.30.100.17.2
NetBotz External Dry Contact 3 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext3 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry3-trap-clear 1.3.6.1.4.1.5528.30.100.17.3
NetBotz External Dry Contact 3 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext3 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry4-traps 1.3.6.1.4.1.5528.30.100.18
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry4-triggered-trap 1.3.6.1.4.1.5528.30.100.18.2
NetBotz External Dry Contact 4 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext4 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry4-trap-clear 1.3.6.1.4.1.5528.30.100.18.3
NetBotz External Dry Contact 4 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext4 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp5-traps 1.3.6.1.4.1.5528.30.100.19
OBJECT IDENTIFIER    

netBotz-prd-bot-amp5-low-trap 1.3.6.1.4.1.5528.30.100.19.1
NetBotz Amp 5 Low Trap. This trap indicates that the lower limit for the fifth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp5-high-trap 1.3.6.1.4.1.5528.30.100.19.2
NetBotz Amp 5 High Trap. This trap indicates that the upper limit for the fifth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp5-trap-clear 1.3.6.1.4.1.5528.30.100.19.3
NetBotz Amp 5 Cleared Trap. The trap has been cleared because the fifth amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp5-sensor-unplugged 1.3.6.1.4.1.5528.30.100.19.6
NetBotz Amp 5 Sensor Unplugged Trap. The sensor for the fifth AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp5-sensor-replugged 1.3.6.1.4.1.5528.30.100.19.7
NetBotz Amp 5 Sensor Replugged Trap. The sensor for the fifth AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp6-traps 1.3.6.1.4.1.5528.30.100.20
OBJECT IDENTIFIER    

netBotz-prd-bot-amp6-low-trap 1.3.6.1.4.1.5528.30.100.20.1
NetBotz Amp 6 Low Trap. This trap indicates that the lower limit for the sixth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp6-high-trap 1.3.6.1.4.1.5528.30.100.20.2
NetBotz Amp 6 High Trap. This trap indicates that the upper limit for the sixth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp6-trap-clear 1.3.6.1.4.1.5528.30.100.20.3
NetBotz Amp 6 Cleared Trap. The trap has been cleared because the sixth amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp6-sensor-unplugged 1.3.6.1.4.1.5528.30.100.20.6
NetBotz Amp 6 Sensor Unplugged Trap. The sensor for the sixth AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp6-sensor-replugged 1.3.6.1.4.1.5528.30.100.20.7
NetBotz Amp 6 Sensor Replugged Trap. The sensor for the sixth AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp7-traps 1.3.6.1.4.1.5528.30.100.21
OBJECT IDENTIFIER    

netBotz-prd-bot-amp7-low-trap 1.3.6.1.4.1.5528.30.100.21.1
NetBotz Amp 7 Low Trap. This trap indicates that the lower limit for the seventh amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp7-high-trap 1.3.6.1.4.1.5528.30.100.21.2
NetBotz Amp 7 High Trap. This trap indicates that the upper limit for the seventh amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp7-trap-clear 1.3.6.1.4.1.5528.30.100.21.3
NetBotz Amp 7 Cleared Trap. The trap has been cleared because the seventh amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp7-sensor-unplugged 1.3.6.1.4.1.5528.30.100.21.6
NetBotz Amp 7 Sensor Unplugged Trap. The sensor for the seventh AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp7-sensor-replugged 1.3.6.1.4.1.5528.30.100.21.7
NetBotz Amp 7 Sensor Replugged Trap. The sensor for the seventh AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp5-traps 1.3.6.1.4.1.5528.30.100.22
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp5-low-trap 1.3.6.1.4.1.5528.30.100.22.1
NetBotz External Temperature 5 Low Trap. This trap indicates that the lower limit for external temperature probe on port 5 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp5-high-trap 1.3.6.1.4.1.5528.30.100.22.2
NetBotz External Temperature 5 High Trap. This trap indicates that the upper limit for external temperature probe on port 5 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp5-trap-clear 1.3.6.1.4.1.5528.30.100.22.3
NetBotz External Temperature 5 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 5 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp5-sensor-unplugged 1.3.6.1.4.1.5528.30.100.22.6
NetBotz External Temperature 5 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp5-sensor-replugged 1.3.6.1.4.1.5528.30.100.22.7
NetBotz External Temperature 5 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp6-traps 1.3.6.1.4.1.5528.30.100.23
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp6-low-trap 1.3.6.1.4.1.5528.30.100.23.1
NetBotz External Temperature 6 Low Trap. This trap indicates that the lower limit for external temperature probe on port 6 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp6-high-trap 1.3.6.1.4.1.5528.30.100.23.2
NetBotz External Temperature 6 High Trap. This trap indicates that the upper limit for external temperature probe on port 6 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp6-trap-clear 1.3.6.1.4.1.5528.30.100.23.3
NetBotz External Temperature 6 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 6 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp6-sensor-unplugged 1.3.6.1.4.1.5528.30.100.23.6
NetBotz External Temperature 6 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp6-sensor-replugged 1.3.6.1.4.1.5528.30.100.23.7
NetBotz External Temperature 6 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp7-traps 1.3.6.1.4.1.5528.30.100.24
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp7-low-trap 1.3.6.1.4.1.5528.30.100.24.1
NetBotz External Temperature 7 Low Trap. This trap indicates that the lower limit for external temperature probe on port 7 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp7-high-trap 1.3.6.1.4.1.5528.30.100.24.2
NetBotz External Temperature 7 High Trap. This trap indicates that the upper limit for external temperature probe on port 7 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp7-trap-clear 1.3.6.1.4.1.5528.30.100.24.3
NetBotz External Temperature 7 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 7 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp7-sensor-unplugged 1.3.6.1.4.1.5528.30.100.24.6
NetBotz External Temperature 7 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp7-sensor-replugged 1.3.6.1.4.1.5528.30.100.24.7
NetBotz External Temperature 7 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry5-traps 1.3.6.1.4.1.5528.30.100.25
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry5-triggered-trap 1.3.6.1.4.1.5528.30.100.25.2
NetBotz External Dry Contact 5 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext5 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry5-trap-clear 1.3.6.1.4.1.5528.30.100.25.3
NetBotz External Dry Contact 5 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext5 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry6-traps 1.3.6.1.4.1.5528.30.100.26
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry6-triggered-trap 1.3.6.1.4.1.5528.30.100.26.2
NetBotz External Dry Contact 6 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext6 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry6-trap-clear 1.3.6.1.4.1.5528.30.100.26.3
NetBotz External Dry Contact 6 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext6 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry7-traps 1.3.6.1.4.1.5528.30.100.27
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry7-triggered-trap 1.3.6.1.4.1.5528.30.100.27.2
NetBotz External Dry Contact 7 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext7 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry7-trap-clear 1.3.6.1.4.1.5528.30.100.27.3
NetBotz External Dry Contact 7 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext7 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-camera-motion-traps 1.3.6.1.4.1.5528.30.100.28
OBJECT IDENTIFIER    

netBotz-prd-bot-camera-motion-trap-tripped 1.3.6.1.4.1.5528.30.100.28.2
NetBotz Camera Motion Sensor Tripped Trap. This trap indicates that the camera motion sensor has been triggered (motion has been detected).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-camera-motion-trap-clear 1.3.6.1.4.1.5528.30.100.28.3
NetBotz Camera Motion Cleared Trap. The trap has been cleared because the camera motion sensor has returned to normal (no longer is detecting motion).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-WallBotz-300 1.3.6.1.4.1.5528.30.1000
OBJECT IDENTIFIER    

netBotz-prd-RackBotz-300 1.3.6.1.4.1.5528.30.1001
OBJECT IDENTIFIER    

netBotz-prd-RackBotz-300U 1.3.6.1.4.1.5528.30.1002
OBJECT IDENTIFIER    

netBotz-prd-WallBotz-400 1.3.6.1.4.1.5528.30.1003
OBJECT IDENTIFIER    

netBotz-prd-RackBotz-400 1.3.6.1.4.1.5528.30.1004
OBJECT IDENTIFIER    

netBotz-prd-RackBotz-303 1.3.6.1.4.1.5528.30.1006
OBJECT IDENTIFIER    

netBotz-prd-WallBotz-310 1.3.6.1.4.1.5528.30.1007
OBJECT IDENTIFIER    

netBotz-prd-RackBotz-310 1.3.6.1.4.1.5528.30.1008
OBJECT IDENTIFIER    

expPortTable 1.3.6.1.4.1.5528.31
A list of expansion port entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ExpPortEntry

expPortEntry 1.3.6.1.4.1.5528.31.1
An expansion port entry for a single port
OBJECT-TYPE    
  ExpPortEntry  

expPort-module-id 1.3.6.1.4.1.5528.31.1.1
The module ID of the sensor module installed. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

expPort-module-type 1.3.6.1.4.1.5528.31.1.2
The type of sensor module installed. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

expPort-amps 1.3.6.1.4.1.5528.31.1.20
The reading of the amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

expPort-total-amp-seconds 1.3.6.1.4.1.5528.31.1.21
The accumulated total of amp-seconds on the AmpDetect.
OBJECT-TYPE    
  INTEGER  

expPort-total-amp-seconds-since-time 1.3.6.1.4.1.5528.31.1.22
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

expPort-amps-enabled 1.3.6.1.4.1.5528.31.1.23
Amperage probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

expPort-amps-min 1.3.6.1.4.1.5528.31.1.24
The amperage probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

expPort-amps-max 1.3.6.1.4.1.5528.31.1.25
The amperage probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

expPort-amps-uV-per-10mA 1.3.6.1.4.1.5528.31.1.26
The scaling factor used for the amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

expPort-amps-max-range 1.3.6.1.4.1.5528.31.1.27
The maximum RMS milliamps measureable by the AmpDetect.
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp 1.3.6.1.4.1.5528.31.1.40
The reading of the external temperature probe, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-enabled 1.3.6.1.4.1.5528.31.1.41
External temperature probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-min 1.3.6.1.4.1.5528.31.1.42
The external temperature probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-max 1.3.6.1.4.1.5528.31.1.43
The external temperature probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-uV-per-degreeC 1.3.6.1.4.1.5528.31.1.44
The scaling factor used for the external temperature probe to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-uV-at-0-degreeC 1.3.6.1.4.1.5528.31.1.45
The offset used for the external temperature probe of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-min-range 1.3.6.1.4.1.5528.31.1.46
The minimum temperature measureable by the temperature sensor, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

expPort-ext-temp-max-range 1.3.6.1.4.1.5528.31.1.47
The maximum temperature measureable by the temperature sensor, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry 1.3.6.1.4.1.5528.31.1.60
The current value of the external dry contact sensor: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry-alarm-value 1.3.6.1.4.1.5528.31.1.61
The value to generate alarms on for the external dry contact sensor: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry-enabled 1.3.6.1.4.1.5528.31.1.62
External dry contact sensor alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry-label 1.3.6.1.4.1.5528.31.1.63
The sensor name/label for the dry contact sensor
OBJECT-TYPE    
  DisplayString  

expPort-ext-dry-open-label 1.3.6.1.4.1.5528.31.1.64
The sensor name/label for the open(0) state for the dry contact sensor
OBJECT-TYPE    
  DisplayString  

expPort-ext-dry-closed-label 1.3.6.1.4.1.5528.31.1.65
The sensor name/label for the closed(0) state for the dry contact sensor
OBJECT-TYPE    
  DisplayString  

expPort-ext-dry-open-to-close-millis 1.3.6.1.4.1.5528.31.1.66
The minimum number of milliseconds that the dry contact sensor must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry-close-to-open-millis 1.3.6.1.4.1.5528.31.1.67
The minimum number of milliseconds that the dry contact sensor must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

expPort-ext-dry-response 1.3.6.1.4.1.5528.31.1.68
The type of alert response for the dry contact sensor: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-snmp 1.3.6.1.4.1.5528.40
OBJECT IDENTIFIER    

netBotz-snmp-traptarget 1.3.6.1.4.1.5528.40.1
Target of traps from the NetBotz device. This field contains the IP address where NetBotz traps are to be sent.
OBJECT-TYPE    
  IpAddress  

netBotz-snmp-community 1.3.6.1.4.1.5528.40.2
The read/write community of the NetBotz device.
OBJECT-TYPE    
  DisplayString  

netBotz-snmp-timeout 1.3.6.1.4.1.5528.40.3
SNMP Timeout period.
OBJECT-TYPE    
  INTEGER  

netBotz-snmp-retries 1.3.6.1.4.1.5528.40.4
SNMP Retry count.
OBJECT-TYPE    
  INTEGER  

netBotz-userid-1 1.3.6.1.4.1.5528.40.5
The userID of the supervisor account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-password-1 1.3.6.1.4.1.5528.40.6
The password of the supervisor account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-userid-2 1.3.6.1.4.1.5528.40.7
The userID of the full read access account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-password-2 1.3.6.1.4.1.5528.40.8
The password of the full read access account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-userid-3 1.3.6.1.4.1.5528.40.9
The userID of the minimum read access account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-password-3 1.3.6.1.4.1.5528.40.10
The password of the minimum read access account (write-only).
OBJECT-TYPE    
  DisplayString  

netBotz-snmp-traptarget2 1.3.6.1.4.1.5528.40.11
Second target of traps from the NetBotz device. This field contains an additional IP address where NetBotz traps are to be sent.
OBJECT-TYPE    
  IpAddress  

netBotz-snmp-read-community 1.3.6.1.4.1.5528.40.12
The read-only community of the NetBotz device.
OBJECT-TYPE    
  DisplayString  

netBotz-device 1.3.6.1.4.1.5528.50
OBJECT IDENTIFIER    

netBotz-dev-host 1.3.6.1.4.1.5528.50.1
NetBotz device's host name.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-domain 1.3.6.1.4.1.5528.50.2
NetBotz device's default DNS domain.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-ip 1.3.6.1.4.1.5528.50.3
NetBotz device's IP address.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-netmask 1.3.6.1.4.1.5528.50.4
NetBotz device's netmask.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-gateway 1.3.6.1.4.1.5528.50.5
NetBotz device's default gateway/router. 0.0.0.0 if not defined.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-primarydns 1.3.6.1.4.1.5528.50.6
Primary Domain Name Server. 0.0.0.0 if not defined.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-secondarydns 1.3.6.1.4.1.5528.50.7
Secondary Domain Name Server. 0.0.0.0 if not defined.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-smtp 1.3.6.1.4.1.5528.50.8
SMTP server address. This is the mail server used for sending alert e-mails.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-smtpport 1.3.6.1.4.1.5528.50.9
SMTP port. Port number of SMTP server used for sending alert e-mails.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-popport 1.3.6.1.4.1.5528.50.10
POP port. Currently, not used.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-loglevel 1.3.6.1.4.1.5528.50.11
This field contains the log level of the NetBotz device. Log messages will be filtered, so that only same or lower-level messages will be passed. The default log level is 5, for warnings and lower levels. The log levels are the following: 1 - emergency 2 - alert 3 - critical 4 - error 5 - warning 6 - notice 7 - info 8 - trace
OBJECT-TYPE    
  INTEGER  

netBotz-dev-logaddress 1.3.6.1.4.1.5528.50.12
This field contains an IP address to receive log messages from the NetBotz device. 0.0.0.0 for no external logging.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-logport 1.3.6.1.4.1.5528.50.13
Port to use in conjunction with the log address, for log messages from the NetBotz device to be sent to an external IP address. 0 = no external logging.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-primaryemail 1.3.6.1.4.1.5528.50.14
The primary email addresses for alerts and messages (list separated by commas for multiple addresses).
OBJECT-TYPE    
  DisplayString  

netBotz-dev-secondaryemail 1.3.6.1.4.1.5528.50.15
The secondary email address for alerts and messages (list separated by commas for multiple addresses).
OBJECT-TYPE    
  DisplayString  

netBotz-dev-pager 1.3.6.1.4.1.5528.50.16
The pager number for alerts and messages. Currently, not used.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-serialno 1.3.6.1.4.1.5528.50.17
The serial number of the NetBotz device.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-pop 1.3.6.1.4.1.5528.50.18
POP server name. Currently, not used.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-version 1.3.6.1.4.1.5528.50.19
The current NetBotz device firmware version.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-registered 1.3.6.1.4.1.5528.50.20
Indicates if the device has been registered with NetBotz, Inc. 1=registered, 0=not registered.
OBJECT-TYPE    
  INTEGER  

netBotz-default-applet 1.3.6.1.4.1.5528.50.21
Setting to control if default web page should launch applet by default(1) or the HTML status page(0).
OBJECT-TYPE    
  INTEGER  

netBotz-guibar-color 1.3.6.1.4.1.5528.50.22
Setting for color of GUI bar (RGB). Value = 0xRRGGBB.
OBJECT-TYPE    
  INTEGER  

netBotz-locale 1.3.6.1.4.1.5528.50.23
The locale ID of the NetBotz device. Format is ISO 639 language (lower case), an underscore, and ISO 3166 country (upper case). Some locales are just the ISO 639 language code.
OBJECT-TYPE    
  DisplayString  

netBotz-timezone 1.3.6.1.4.1.5528.50.24
The timezone ID of the NetBotz device.
OBJECT-TYPE    
  DisplayString  

netBotz-24hourpreferred 1.3.6.1.4.1.5528.50.25
Indicates if 24-hour(1) versus 12-hour(0) time format is preferred.
OBJECT-TYPE    
  INTEGER  

netBotz-utc-clock 1.3.6.1.4.1.5528.50.26
Current time of clock on NetBotz device, in UTC seconds (seconds since 1/1/1970 12:00am GMT).
OBJECT-TYPE    
  INTEGER  

netBotz-ismetric 1.3.6.1.4.1.5528.50.27
Units are metric (1) or U.S. (0). Applies to temperature and airflow rate.
OBJECT-TYPE    
  INTEGER  

netBotz-alert-url 1.3.6.1.4.1.5528.50.28
The URL, if defined, to which non-picture alerts are HTTP POSTed
OBJECT-TYPE    
  DisplayString  

netBotz-picture-alert-url 1.3.6.1.4.1.5528.50.29
The URL, if defined, to which picture alerts are HTTP POSTed, using multipart/form-data encoding.
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-data-url 1.3.6.1.4.1.5528.50.30
The URL, if defined, to which sensor data is periodically HTTP POSTed.
OBJECT-TYPE    
  DisplayString  

netBotz-alert-url-logon 1.3.6.1.4.1.5528.50.31
The user ID and password, if defined, used for POSTing non-picture alerts. Field is write-only, and formatted /
OBJECT-TYPE    
  DisplayString  

netBotz-picture-alert-url-logon 1.3.6.1.4.1.5528.50.32
The user ID and password, if defined, used for POSTing picture alerts. Field is write-only, and formatted /
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-data-url-logon 1.3.6.1.4.1.5528.50.33
The user ID and password, if defined, used for POSTing sensor data. Field is write-only, and formatted /
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-data-url-period 1.3.6.1.4.1.5528.50.34
Default number of minutes between periodic sensor data HTTP POSTs.
OBJECT-TYPE    
  INTEGER  

netBotz-sensor-data-url-flags 1.3.6.1.4.1.5528.50.35
Option flags for data POSTs of sensor data. Bit 0=1 if current picture should be included. Bits 1-31 are reserved.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-backup-smtp 1.3.6.1.4.1.5528.50.36
Backup SMTP server address. This is the backup mail server used for sending alert e-mails.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-tertiarydns 1.3.6.1.4.1.5528.50.37
Tertiary Domain Name Server. 0.0.0.0 if not defined.
OBJECT-TYPE    
  IpAddress  

netBotz-dev-ntp-server 1.3.6.1.4.1.5528.50.38
NTP (Network Time Protocol) Server configured for appliance.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-ntp-period 1.3.6.1.4.1.5528.50.39
Hours between automatic refreshes of the appliance clock using the NTP server.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-socks-server 1.3.6.1.4.1.5528.50.40
Socks V4 or V5 proxy server configured for appliance.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-socks-portnum 1.3.6.1.4.1.5528.50.41
Port number of Socks Proxy.
OBJECT-TYPE    
  INTEGER  

netBotz-dev-socks-user-id 1.3.6.1.4.1.5528.50.42
User ID for Socks V4 or V5 proxy server configured for appliance.
OBJECT-TYPE    
  DisplayString  

netBotz-dev-socks-password 1.3.6.1.4.1.5528.50.43
Password for Socks V4 or V5 proxy server configured for appliance.
OBJECT-TYPE    
  DisplayString  

netBotz-alert-ftp-site 1.3.6.1.4.1.5528.50.44
The hostname or dotted-decimal IP address of the FTP server to deliver alerts to
OBJECT-TYPE    
  DisplayString  

netBotz-alert-ftp-path 1.3.6.1.4.1.5528.50.45
The directory on the FTP server to store alerts in.
OBJECT-TYPE    
  DisplayString  

netBotz-alert-ftp-filename 1.3.6.1.4.1.5528.50.46
The base filename for the files on the FTP server to store alerts in.
OBJECT-TYPE    
  DisplayString  

netBotz-alert-ftp-logon 1.3.6.1.4.1.5528.50.47
The user-id and password on the FTP server to store alerts in. Field is write-only, and formatted /
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-ftp-site 1.3.6.1.4.1.5528.50.48
The hostname or dotted-decimal IP address of the FTP server to deliver periodic sensor reports to
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-ftp-path 1.3.6.1.4.1.5528.50.49
The directory on the FTP server to store periodic sensor reports in.
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-ftp-filename 1.3.6.1.4.1.5528.50.50
The base filename for the files on the FTP server to store periodic sensor reports in.
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-ftp-logon 1.3.6.1.4.1.5528.50.51
The user-id and password on the FTP server to store sensor reports in. Field is write-only, and formatted /
OBJECT-TYPE    
  DisplayString  

netBotz-sensor-ftp-period 1.3.6.1.4.1.5528.50.52
The period, in minutes, between delivery of sensor data reports.
OBJECT-TYPE    
  INTEGER  

Defined Objects

ExpPortEntry  
SEQUENCE    
  DisplayString as expPort-module-id  
  DisplayString as expPort-module-type  
  INTEGER as expPort-amps  
  INTEGER as expPort-total-amp-seconds  
  INTEGER as expPort-total-amp-seconds-since-time  
  INTEGER as expPort-amps-enabled  
  INTEGER as expPort-amps-min  
  INTEGER as expPort-amps-max  
  INTEGER as expPort-amps-uV-per-10mA  
  INTEGER as expPort-amps-max-range  
  INTEGER as expPort-ext-temp  
  INTEGER as expPort-ext-temp-enabled  
  INTEGER as expPort-ext-temp-min  
  INTEGER as expPort-ext-temp-max  
  INTEGER as expPort-ext-temp-uV-per-degreeC  
  INTEGER as expPort-ext-temp-uV-at-0-degreeC  
  INTEGER as expPort-ext-temp-min-range  
  INTEGER as expPort-ext-temp-max-range  
  INTEGER as expPort-ext-dry  
  INTEGER as expPort-ext-dry-alarm-value  
  INTEGER as expPort-ext-dry-enabled  
  DisplayString as expPort-ext-dry-label  
  DisplayString as expPort-ext-dry-open-label  
  DisplayString as expPort-ext-dry-closed-label  
  INTEGER as expPort-ext-dry-open-to-close-millis  
  INTEGER as expPort-ext-dry-close-to-open-millis  
  DisplayString as expPort-ext-dry-response