NNCEXTE3-MIB
File:
NNCEXTE3-MIB.mib (27643 bytes)
Imported modules
Imported symbols
Defined Objects
| nncExtE3 |
1.3.6.1.4.1.123.3.40 |
| This module contains definitions for Newbridge extensions to E3 objects. It is used as a supplement to rfc1407. |
| MODULE-IDENTITY |
|
|
|
| nncExtE3Current15MinEntry |
1.3.6.1.4.1.123.3.40.1.1.1 |
| An entry in nncExtE3Current15MinTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3Current15MinEntry |
|
|
| nncExtE3Current15MinESs |
1.3.6.1.4.1.123.3.40.1.1.1.1 |
| The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Current15MinSESs |
1.3.6.1.4.1.123.3.40.1.1.1.2 |
| The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Current15MinSEFs |
1.3.6.1.4.1.123.3.40.1.1.1.3 |
| The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the current 15 minute interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Interval15MinEntry |
1.3.6.1.4.1.123.3.40.1.2.1 |
| An entry in nncExtE3Interval15MinTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3Interval15MinEntry |
|
|
| nncExtE3Interval15MinNumber |
1.3.6.1.4.1.123.3.40.1.2.1.1 |
| A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid). |
| OBJECT-TYPE |
|
|
|
| |
Integer32 |
1..96 |
|
| nncExtE3Interval15MinESs |
1.3.6.1.4.1.123.3.40.1.2.1.2 |
| The counter associated with the number of Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Interval15MinSESs |
1.3.6.1.4.1.123.3.40.1.2.1.3 |
| The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Interval15MinSEFs |
1.3.6.1.4.1.123.3.40.1.2.1.4 |
| The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in one of the previous 15 minute intervals. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Total24HrEntry |
1.3.6.1.4.1.123.3.40.1.3.1 |
| An entry in nncExtE3Total24HrTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3Total24HrEntry |
|
|
| nncExtE3Total24HrESs |
1.3.6.1.4.1.123.3.40.1.3.1.1 |
| The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Total24HrSESs |
1.3.6.1.4.1.123.3.40.1.3.1.2 |
| The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3Total24HrSEFs |
1.3.6.1.4.1.123.3.40.1.3.1.3 |
| The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the previous 24 hours interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndCurrent15MinEntry |
1.3.6.1.4.1.123.3.40.1.4.1 |
| An entry in nncExtE3FarEndCurrent15MinTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3FarEndCurrent15MinEntry |
|
|
| nncExtE3FarEndCurrent15MinFEBEs |
1.3.6.1.4.1.123.3.40.1.4.1.1 |
| The counter associated with the number of Far End Block Errors encountered by a E3 interface in the current 15 minute interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndCurrent15MinESs |
1.3.6.1.4.1.123.3.40.1.4.1.2 |
| The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndCurrent15MinSESs |
1.3.6.1.4.1.123.3.40.1.4.1.3 |
| The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndInterval15MinEntry |
1.3.6.1.4.1.123.3.40.1.5.1 |
| An entry in nncExtE3FarEndInterval15MinTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3FarEndInterval15MinEntry |
|
|
| nncExtE3FarEndInterval15MinNumber |
1.3.6.1.4.1.123.3.40.1.5.1.1 |
| A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid). |
| OBJECT-TYPE |
|
|
|
| |
Integer32 |
1..96 |
|
| nncExtE3FarEndInterval15MinFEBEs |
1.3.6.1.4.1.123.3.40.1.5.1.2 |
| The counter associated with the number of Far End Block Errors encountered by a E3 interface in one of the previous 15 minute intervals. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndInterval15MinESs |
1.3.6.1.4.1.123.3.40.1.5.1.3 |
| The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndInterval15MinSESs |
1.3.6.1.4.1.123.3.40.1.5.1.4 |
| The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndTotal24HrEntry |
1.3.6.1.4.1.123.3.40.1.6.1 |
| An entry in nncExtE3FarEndTotal24HrTable. |
| OBJECT-TYPE |
|
|
|
| |
NncExtE3FarEndTotal24HrEntry |
|
|
| nncExtE3FarEndTotal24HrFEBEs |
1.3.6.1.4.1.123.3.40.1.6.1.1 |
| The counter associated with the number of Far End Block Errors encountered by a E3 interface in the previous 24 hours interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndTotal24HrESs |
1.3.6.1.4.1.123.3.40.1.6.1.2 |
| The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
| nncExtE3FarEndTotal24HrSESs |
1.3.6.1.4.1.123.3.40.1.6.1.3 |
| The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode. |
| OBJECT-TYPE |
|
|
|
| |
Gauge32 |
|
|
Defined Objects
| NncExtE3Current15MinEntry |
|
| SEQUENCE |
|
|
|
| |
Gauge32 as nncExtE3Current15MinESs |
|
|
| |
Gauge32 as nncExtE3Current15MinSESs |
|
|
| |
Gauge32 as nncExtE3Current15MinSEFs |
|
|
| NncExtE3Interval15MinEntry |
|
| SEQUENCE |
|
|
|
| |
Integer32 as nncExtE3Interval15MinNumber |
|
|
| |
Gauge32 as nncExtE3Interval15MinESs |
|
|
| |
Gauge32 as nncExtE3Interval15MinSESs |
|
|
| |
Gauge32 as nncExtE3Interval15MinSEFs |
|
|
| NncExtE3Total24HrEntry |
|
| SEQUENCE |
|
|
|
| |
Gauge32 as nncExtE3Total24HrESs |
|
|
| |
Gauge32 as nncExtE3Total24HrSESs |
|
|
| |
Gauge32 as nncExtE3Total24HrSEFs |
|
|
| NncExtE3FarEndCurrent15MinEntry |
|
| SEQUENCE |
|
|
|
| |
Gauge32 as nncExtE3FarEndCurrent15MinFEBEs |
|
|
| |
Gauge32 as nncExtE3FarEndCurrent15MinESs |
|
|
| |
Gauge32 as nncExtE3FarEndCurrent15MinSESs |
|
|
| NncExtE3FarEndInterval15MinEntry |
|
| SEQUENCE |
|
|
|
| |
Integer32 as nncExtE3FarEndInterval15MinNumber |
|
|
| |
Gauge32 as nncExtE3FarEndInterval15MinFEBEs |
|
|
| |
Gauge32 as nncExtE3FarEndInterval15MinESs |
|
|
| |
Gauge32 as nncExtE3FarEndInterval15MinSESs |
|
|
| NncExtE3FarEndTotal24HrEntry |
|
| SEQUENCE |
|
|
|
| |
Gauge32 as nncExtE3FarEndTotal24HrFEBEs |
|
|
| |
Gauge32 as nncExtE3FarEndTotal24HrESs |
|
|
| |
Gauge32 as nncExtE3FarEndTotal24HrSESs |
|
|