NNCEXTSPVC-MIB

File: NNCEXTSPVC-MIB.mib (147479 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
ATM-MIB SNMPv2-CONF NNCGNI0001-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
NOTIFICATION-TYPE TEXTUAL-CONVENTION RowStatus
ifIndex atmVplVpi atmVclVpi
atmVclVci MODULE-COMPLIANCE OBJECT-GROUP
nncExtensions

Defined Objects

nncExtSpvc 1.3.6.1.4.1.123.3.82
This module contains Alcatel CID's proprietary MIB definition for managing Soft Permanent Virtual Connections (SPVCs). This MIB supports the creation, modification, query, and deletion of SPVCs (Soft Permanent Virtual Connections), on Cell Relay (ATM), Frame Relay, and Circuit Emulation endpoints. For Cell Relay-based endpoints, Permanent Virtual Path Connection (PVPC) and Permanent Virtual Channel Connection (PVCC) are supported, while SPVCCs are supported on Frame Relay and Circuit Emulation endpoints. Cell Relay SPVCs, Frame Relay SPVCs and Circuit Emulation SPVCs are supported in this MIB. SPVCs with any other service types are not supported at this point. For SPVCs interworking across different endpoint types, CR to FR, FR to CR, CR to CE, CE to CR connections are supported. CE to FR or FR to CE are not suppported. Operator directed routing for SPVC connections is not supported at this point. To create an SPVC, the required MIB objects from the destination table must be configured and sent to the destination endpoint. Next, the MIB objects from the source endpoint table (based on the endpoint type and SPVC type - either nncCrSpvpcTable, nncCrSpvccTable, nncFrSpvcTable, or nncCeSpvcTable) are configured and sent to the source endpoint. Assuming a PDU with a RowStatus of 'createAndGo' or 'Active' has been received, if the adminStatus of the SPVC is set to 'enabled', the SPVC will be connected; if the adminStatus of the SPVC is set to 'disabled', the SPVC will be configured but not connected. SPVC creation SET-REQuests can be sent two ways: using a RowStatus value of 'createAndGo', or using multiple SET-REQs using RowStatus values of 'createAndWait' and 'active'. Creating an SPVC using rowStatus=createAndWait(5) In the case of multiple SET-REQs, the RowStatus is set to createAndWait(5) for all but the last SET-REQ, and set to active(1) for the last SET-REQ. The SPVC is configured only after the last PDU (with RowStatus as 'active') is received. Creating an SPVC using rowStatus=createAndGo(4) In the other case, all required MIB objects can fit in one SET-REQ. If using only one SET-REQ, the RowStatus should be set to createAndGo(4). In both cases, default values for MIB objects will be used wherever possible. To delete an SPVC, the correct table objects must be sent to both the destination endpoint and the source endpoint for the given SPVC, using the correct index, and setting the rowStatus to 'destroy'. This will delete the specified SPVC. Some abreviations: abr/ABR/Abr: Available Bit Rate Bwd: Backward. For traffice descriptors from destination endpoint to source endpoint (receiving traffic) cbr/CBR/Cbr: Constant Bit Rate Dst: Destination endpoint Fwd: Forward. For traffic descriptors from source endpoint to destination endpoint (transmitting traffic) nt-vbr/nrtvbr/NRT-VBR: Non-Real-Time Variable Bit Rate Src: Source endpoint Targ: Target. For the destination endpoint info in source endpoint table ubr/UBR/Ubr: Unspecified Bit Rate
MODULE-IDENTITY    

nncExtSpvcObjects 1.3.6.1.4.1.123.3.82.1
OBJECT IDENTIFIER    

nncCrSpvpcTable 1.3.6.1.4.1.123.3.82.1.1
nncCrSpvpcTable contains all the objects sent to a source endpoint that are used to create, modify, query and delete SPVC connections.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCrSpvpcTableEntry

nncCrSpvpcTableEntry 1.3.6.1.4.1.123.3.82.1.1.1
An entry of nncCrSpvpcTable
OBJECT-TYPE    
  NncCrSpvpcTableEntry  

nncCrSpvpcServiceCategory 1.3.6.1.4.1.123.3.82.1.1.1.1
This object is used to set the traffic service category. This object is dependent on the value specified in nncCrSpvpcTrafficDescriptor
OBJECT-TYPE    
  INTEGER cbr(1), nrtvbr(2), abr(3), ubr(4), rtvbr(6)  

nncCrSpvpcTargEpAddr 1.3.6.1.4.1.123.3.82.1.1.1.2
This object is used to specify the 20 byte AESA address for the target endpoint. The address map is as the following: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | 0 | ------------------------------------------------------------------------
OBJECT-TYPE    
  AtmFormatDisplay  

nncCrSpvpcTargVpi 1.3.6.1.4.1.123.3.82.1.1.1.3
This object contains the virtual path identifier (VPI) value for the target endpoint. Range: 0 - 4095
OBJECT-TYPE    
  INTEGER 0..4095  

nncCrSpvpcAdminStatus 1.3.6.1.4.1.123.3.82.1.1.1.4
This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCrSpvpcAdminStatus to determine if the connection is successful.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nncCrSpvpcPriority 1.3.6.1.4.1.123.3.82.1.1.1.5
This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16
OBJECT-TYPE    
  INTEGER 1..16  

nncCrSpvpcMaxAdminWeight 1.3.6.1.4.1.123.3.82.1.1.1.6
This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647
OBJECT-TYPE    
  Integer32 -1..2147483647  

nncCrSpvpcOperation 1.3.6.1.4.1.123.3.82.1.1.1.7
This object is used to request a reroute operation. Querying this object will not provide any useful information.
OBJECT-TYPE    
  INTEGER reRouteDualEp(7)  

nncCrSpvpcCallStatus 1.3.6.1.4.1.123.3.82.1.1.1.8
This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'.
OBJECT-TYPE    
  INTEGER connected(2), waitingForResources(4), readyToConnect(7)  

nncCrSpvpcLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.1.1.9
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncCrSpvpcFwdAbrDynTrfcIcr 1.3.6.1.4.1.123.3.82.1.1.1.10
ABR dynamic traffic descriptor's Initial Cell (Information) Rate for the forward direction. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcFwdAbrDynTrfcRif 1.3.6.1.4.1.123.3.82.1.1.1.11
ABR traffic Rate Increase Factor for the forward direction. Value is expressed as the -power of 2. Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvpcFwdAbrDynTrfcRdf 1.3.6.1.4.1.123.3.82.1.1.1.12
ABR traffic Rate Decrease Factor descriptor for the forward direction. Value is expressed as the -power of 2 Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvpcBwdAbrDynTrfcIcr 1.3.6.1.4.1.123.3.82.1.1.1.13
ABR dynamic traffic descriptor's Initial Cell Rate for the destination endpoint. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcBwdAbrDynTrfcRif 1.3.6.1.4.1.123.3.82.1.1.1.14
ABR traffic Rate Increase Factor for the backward direction. Value is expressed as the -power of 2. Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvpcBwdAbrDynTrfcRdf 1.3.6.1.4.1.123.3.82.1.1.1.15
ABR traffic Rate Decrease Factor descriptor for the backward direction. Value is expressed as the -power of 2 Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvpcSrcBillingFlag 1.3.6.1.4.1.123.3.82.1.1.1.16
Billing Configuration for the source endpoint
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvpcFwdTmTrafficDescriptor 1.3.6.1.4.1.123.3.82.1.1.1.17
This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only)
OBJECT-TYPE    
  INTEGER tagAll(1), p0Plus1(2), p0Plus1SlashS0Plus1(3), p0Plus1SlashS0(4), p0Plus1SlashM0Plus1(5)  

nncCrSpvpcFwdTmPolicingOption 1.3.6.1.4.1.123.3.82.1.1.1.18
Policing Option for an SPVPC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor
OBJECT-TYPE    
  INTEGER disabled(1), tag(2), discard(3)  

nncCrSpvpcFwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.1.1.19
This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcFwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.1.1.20
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvpcFwdTmBucketTwoRate 1.3.6.1.4.1.123.3.82.1.1.1.21
SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcFwdTmBucketTwoMbs 1.3.6.1.4.1.123.3.82.1.1.1.22
This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells
OBJECT-TYPE    
  INTEGER 1..10000  

nncCrSpvpcFwdTmCdv 1.3.6.1.4.1.123.3.82.1.1.1.23
This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds
OBJECT-TYPE    
  INTEGER 250..10000  

nncCrSpvpcFwdTmClr 1.3.6.1.4.1.123.3.82.1.1.1.24
The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-#
OBJECT-TYPE    
  INTEGER 1..7  

nncCrSpvpcBwdTmTrafficDescriptor 1.3.6.1.4.1.123.3.82.1.1.1.25
This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only)
OBJECT-TYPE    
  INTEGER tagAll(1), p0Plus1(2), p0Plus1SlashS0Plus1(3), p0Plus1SlashS0(4), p0Plus1SlashM0Plus1(5)  

nncCrSpvpcBwdTmPolicingOption 1.3.6.1.4.1.123.3.82.1.1.1.26
Policing Option for an SPVPC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor
OBJECT-TYPE    
  INTEGER disabled(1), tag(2), discard(3)  

nncCrSpvpcBwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.1.1.27
This object is for peak information rate (PIR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcBwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.1.1.28
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvpcBwdTmBucketTwoRate 1.3.6.1.4.1.123.3.82.1.1.1.29
SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvpcBwdTmBucketTwoMbs 1.3.6.1.4.1.123.3.82.1.1.1.30
This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells
OBJECT-TYPE    
  INTEGER 1..10000  

nncCrSpvpcBwdTmCdv 1.3.6.1.4.1.123.3.82.1.1.1.31
This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds
OBJECT-TYPE    
  INTEGER 250..10000  

nncCrSpvpcBwdTmClr 1.3.6.1.4.1.123.3.82.1.1.1.32
The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-#
OBJECT-TYPE    
  INTEGER 1..7  

nncCrSpvpcCreator 1.3.6.1.4.1.123.3.82.1.1.1.33
The object retrieves the creator of a SPVC connection.
OBJECT-TYPE    
  INTEGER unknown(0), nmti(1), nm5620(2), snmp(9)  

nncCrSpvpcRowStatus 1.3.6.1.4.1.123.3.82.1.1.1.34
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncCrSpvpcDstCfgTable 1.3.6.1.4.1.123.3.82.1.2
the nncCrSpvpcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCrSpvpcDstCfgTableEntry

nncCrSpvpcDstCfgTableEntry 1.3.6.1.4.1.123.3.82.1.2.1
An entry of nncCrSpvpcDstCfgTable.
OBJECT-TYPE    
  NncCrSpvpcDstCfgTableEntry  

nncCrSpvpcDstCfgCdvt 1.3.6.1.4.1.123.3.82.1.2.1.1
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvpcDstCfgPolicing 1.3.6.1.4.1.123.3.82.1.2.1.2
CR Policing
OBJECT-TYPE    
  INTEGER nullPolicing(0), disabled(1), tag(2), discard(3), useSignalled(4)  

nncCrSpvpcDstCfgBillingFlag 1.3.6.1.4.1.123.3.82.1.2.1.3
Billing Configuration for the destination endpoint.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvpcDstCfgLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.2.1.4
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncCrSpvpcDstCfgRowStatus 1.3.6.1.4.1.123.3.82.1.2.1.5
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncCrSpvccTable 1.3.6.1.4.1.123.3.82.1.3
nncCrSpvccTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query Cell Relay SPVC connections.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCrSpvccTableEntry

nncCrSpvccTableEntry 1.3.6.1.4.1.123.3.82.1.3.1
An entry of nncCrSpvccTable. It contains the objects required to manage CR SPVCs.
OBJECT-TYPE    
  NncCrSpvccTableEntry  

nncCrSpvccServiceCategory 1.3.6.1.4.1.123.3.82.1.3.1.1
This object is used to set the traffic service category. This object is dependent on the value specified in nncCrSpvccTrafficDescriptor
OBJECT-TYPE    
  INTEGER cbr(1), nrtvbr(2), abr(3), ubr(4), rtvbr(6)  

nncCrSpvccTargEpAddr 1.3.6.1.4.1.123.3.82.1.3.1.2
This object is used to specify the AESA address for the target endpoint. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | 0 | ------------------------------------------------------------------------
OBJECT-TYPE    
  AtmFormatDisplay  

nncCrSpvccTargVpi 1.3.6.1.4.1.123.3.82.1.3.1.3
This object contains the virtual path identifier (VPI) value for the target endpoint. Range: 0 - 4095
OBJECT-TYPE    
  INTEGER 0..4095  

nncCrSpvccTargVci 1.3.6.1.4.1.123.3.82.1.3.1.4
This object contains the virtual channel identifier (VCI) value for the target endpoint. Range: 1 - 65535
OBJECT-TYPE    
  INTEGER 1..65535  

nncCrSpvccTargDlci 1.3.6.1.4.1.123.3.82.1.3.1.5
This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the target endpoint, and has only local significance to the specified link. Range: 16 - 1023
OBJECT-TYPE    
  INTEGER 16..1023  

nncCrSpvccTargCeNumber 1.3.6.1.4.1.123.3.82.1.3.1.6
This object contains circuit number, channel group number or both for the Circuit Emulation endpoint. Used in CR to CE connections when nncCrSpvccTargEpType is configured as circuitEmulation(3). For CE connections on unchannelized DS3_CCE card, it's the circuit number 1-28 for UDT circuit number For CE connections on unchannelized E3_CCE card, it's the circuit number 1-16 for UDT circuit number For CE connections on E1/T1 CES, it's channel group number. 0 for UDT mode, both T1 and E1 1-31 for E1 in SDT mode 1-24 for T1 in SDT mode For CE connections on channelized DS3_CCE-2 card, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 28 for channelized DS3, = 0 for unstructured DS3) channelGroupNum (bits 1-8, = 1 to 24 for SDT mode, = 0 for UDT Mode) For CE connections on channelized E3_CCE-2, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 16) channelGroupNum (bits 1-8, = 1 to 31 for SDT mode, = 0 for UDT Mode) Example: Circuit Number = 7, Channel Group = 3 : nncCrSpvccTargCeNumber = (Circuit Number * 256) + Channel Group = 1795 SPVCs across service types other than circuit emulation do not require this object.
OBJECT-TYPE    
  INTEGER 0..65535  

nncCrSpvccTargEpType 1.3.6.1.4.1.123.3.82.1.3.1.7
This object specifies a target endpoint as one of the following types: cellRelay (1) frameRelay (2) circuitEmulation (3)
OBJECT-TYPE    
  INTEGER cellRelay(1), frameRelay(2), circuitEmulation(3)  

nncCrSpvccAdminStatus 1.3.6.1.4.1.123.3.82.1.3.1.8
This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCrSpvccAdminStatus to determine if the connection is successful.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nncCrSpvccPriority 1.3.6.1.4.1.123.3.82.1.3.1.9
This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16
OBJECT-TYPE    
  INTEGER 1..16  

nncCrSpvccMaxAdminWeight 1.3.6.1.4.1.123.3.82.1.3.1.10
This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647
OBJECT-TYPE    
  Integer32 -1..2147483647  

nncCrSpvccOperation 1.3.6.1.4.1.123.3.82.1.3.1.11
This object is used to request a reroute operation. Querying this object will not provide any useful information.
OBJECT-TYPE    
  INTEGER reRouteDualEp(7)  

nncCrSpvccCallStatus 1.3.6.1.4.1.123.3.82.1.3.1.12
This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'.
OBJECT-TYPE    
  INTEGER connected(2), waitingForResources(4), readyToConnect(7)  

nncCrSpvccLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.3.1.13
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncCrSpvccFwdAbrDynTrfcIcr 1.3.6.1.4.1.123.3.82.1.3.1.14
ABR dynamic traffic descriptor's Initial Cell Rate for the forward direction. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccFwdAbrDynTrfcRif 1.3.6.1.4.1.123.3.82.1.3.1.15
ABR traffic Rate Increase Factor for the forward direction. Value is expressed as the -power of 2. Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvccFwdAbrDynTrfcRdf 1.3.6.1.4.1.123.3.82.1.3.1.16
ABR traffic Rate Decrease Factor descriptor for the forward direction. Value is expressed as the -power of 2 Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvccBwdAbrDynTrfcIcr 1.3.6.1.4.1.123.3.82.1.3.1.17
ABR dynamic traffic descriptor's Initial Cell Rate for the destination endpoint. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccBwdAbrDynTrfcRif 1.3.6.1.4.1.123.3.82.1.3.1.18
ABR traffic Rate Increase Factor for the backward direction. Value is expressed as the -power of 2. Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvccBwdAbrDynTrfcRdf 1.3.6.1.4.1.123.3.82.1.3.1.19
ABR traffic Rate Decrease Factor descriptor for the backward direction. Value is expressed as the -power of 2 Range: 0 - 9
OBJECT-TYPE    
  INTEGER 0..9  

nncCrSpvccSrcBillingFlag 1.3.6.1.4.1.123.3.82.1.3.1.20
Billing Configuration for the source endpoint
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccFwdTmTrafficDescriptor 1.3.6.1.4.1.123.3.82.1.3.1.21
This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only)
OBJECT-TYPE    
  INTEGER tagAll(1), p0Plus1(2), p0Plus1SlashS0Plus1(3), p0Plus1SlashS0(4), p0Plus1SlashM0Plus1(5)  

nncCrSpvccFwdTmPolicingOption 1.3.6.1.4.1.123.3.82.1.3.1.22
Policing Option for an SPVCC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor
OBJECT-TYPE    
  INTEGER disabled(1), tag(2), discard(3)  

nncCrSpvccFwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.3.1.23
This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccFwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.3.1.24
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvccFwdTmBucketTwoRate 1.3.6.1.4.1.123.3.82.1.3.1.25
SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccFwdTmBucketTwoMbs 1.3.6.1.4.1.123.3.82.1.3.1.26
This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells
OBJECT-TYPE    
  INTEGER 1..10000  

nncCrSpvccFwdTmCdv 1.3.6.1.4.1.123.3.82.1.3.1.27
This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds
OBJECT-TYPE    
  INTEGER 250..10000  

nncCrSpvccFwdTmClr 1.3.6.1.4.1.123.3.82.1.3.1.28
The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-#
OBJECT-TYPE    
  INTEGER 1..7  

nncCrSpvccFwdTmFrameDiscard 1.3.6.1.4.1.123.3.82.1.3.1.29
The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccBwdTmTrafficDescriptor 1.3.6.1.4.1.123.3.82.1.3.1.30
This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only)
OBJECT-TYPE    
  INTEGER tagAll(1), p0Plus1(2), p0Plus1SlashS0Plus1(3), p0Plus1SlashS0(4), p0Plus1SlashM0Plus1(5)  

nncCrSpvccBwdTmPolicingOption 1.3.6.1.4.1.123.3.82.1.3.1.31
Policing Option for an SPVCC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor
OBJECT-TYPE    
  INTEGER disabled(1), tag(2), discard(3)  

nncCrSpvccBwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.3.1.32
This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccBwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.3.1.33
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvccBwdTmBucketTwoRate 1.3.6.1.4.1.123.3.82.1.3.1.34
SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCrSpvccBwdTmBucketTwoMbs 1.3.6.1.4.1.123.3.82.1.3.1.35
This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrt-VBR and rt-VBR only). Range: 1 - 10000 cells
OBJECT-TYPE    
  INTEGER 1..10000  

nncCrSpvccBwdTmCdv 1.3.6.1.4.1.123.3.82.1.3.1.36
This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds
OBJECT-TYPE    
  INTEGER 250..10000  

nncCrSpvccBwdTmClr 1.3.6.1.4.1.123.3.82.1.3.1.37
The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-#
OBJECT-TYPE    
  INTEGER 1..7  

nncCrSpvccBwdTmFrameDiscard 1.3.6.1.4.1.123.3.82.1.3.1.38
The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccFrBwdTmAr 1.3.6.1.4.1.123.3.82.1.3.1.39
This object is used to specify the Access Rate, in Kb/s.
OBJECT-TYPE    
  INTEGER 0..44210  

nncCrSpvccFrBwdTmCir 1.3.6.1.4.1.123.3.82.1.3.1.40
The committed Information Rate, in Kb/s.
OBJECT-TYPE    
  INTEGER 0..44210  

nncCrSpvccFrBwdTmBc 1.3.6.1.4.1.123.3.82.1.3.1.41
The Committed Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncCrSpvccFrBwdTmBe 1.3.6.1.4.1.123.3.82.1.3.1.42
The Excess Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncCrSpvccFrBwdTmIwf 1.3.6.1.4.1.123.3.82.1.3.1.43
Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4)
OBJECT-TYPE    
  INTEGER none(0), networkInterworking(2), serviceInterworking(3), fFwdInterworking(4)  

nncCrSpvccFrBwdTmPo 1.3.6.1.4.1.123.3.82.1.3.1.44
Policing
OBJECT-TYPE    
  INTEGER disabled(1), enabled(3)  

nncCrSpvccFrBwdTmPacing 1.3.6.1.4.1.123.3.82.1.3.1.45
Pacing
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccFrBwdTmPtclMapping 1.3.6.1.4.1.123.3.82.1.3.1.46
Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmSIWProfile. Values: transparent (0), translated (1) (see also nncFrSpvcTmSIWProfile)
OBJECT-TYPE    
  INTEGER transparent(0), translated(1)  

nncCrSpvccFrBwdTmClpMapping 1.3.6.1.4.1.123.3.82.1.3.1.47
Cell Loss Priority Mapping. Values: cLPEqualsDE (CLP = DE, 0) cLPEquals0 (CLP = 0, 1 ) cLPEquals1 (CLP = 1, 2 )
OBJECT-TYPE    
  INTEGER cLPEqualsDE(0), cLPEquals0(1), cLPEquals1(2)  

nncCrSpvccFrBwdTmDeMapping 1.3.6.1.4.1.123.3.82.1.3.1.48
Discard Eligibility Mapping Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking.
OBJECT-TYPE    
  INTEGER dEEqualsCLP(0), dESSCSor0(1), dEEquals1(2)  

nncCrSpvccFrBwdTmEfciMapping 1.3.6.1.4.1.123.3.82.1.3.1.49
Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (EFCI = FECN, 0) eFCIEquals0 (EFCI = 0, 1)
OBJECT-TYPE    
  INTEGER eFCIEqualsFECN(0), eFCIEquals0(1)  

nncCrSpvccFrBwdTmPvcMgntProfile 1.3.6.1.4.1.123.3.82.1.3.1.50
Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected.
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

nncCrSpvccFrBwdTmSIWProfile 1.3.6.1.4.1.123.3.82.1.3.1.51
The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attributes nncFrSpvcTmIwf and nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 = 16.
OBJECT-TYPE    
  INTEGER 1..16  

nncCrSpvccCreator 1.3.6.1.4.1.123.3.82.1.3.1.52
The object retrieves the creator of a SPVC connection.
OBJECT-TYPE    
  INTEGER unknown(0), nmti(1), nm5620(2), snmp(9)  

nncCrSpvccRowStatus 1.3.6.1.4.1.123.3.82.1.3.1.53
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncCrSpvccDstCfgTable 1.3.6.1.4.1.123.3.82.1.4
the nncCrSpvccDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCrSpvccDstCfgTableEntry

nncCrSpvccDstCfgTableEntry 1.3.6.1.4.1.123.3.82.1.4.1
An entry of nncCrSpvccDstCfgTable.
OBJECT-TYPE    
  NncCrSpvccDstCfgTableEntry  

nncCrSpvccDstCfgCdvt 1.3.6.1.4.1.123.3.82.1.4.1.1
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCrSpvccDstCfgPolicing 1.3.6.1.4.1.123.3.82.1.4.1.2
CR Policing
OBJECT-TYPE    
  INTEGER nullPolicing(0), disabled(1), tag(2), discard(3), useSignalled(4)  

nncCrSpvccDstCfgBillingFlag 1.3.6.1.4.1.123.3.82.1.4.1.3
Billing Configuration for the destination endpoint
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccDstCfgFrVsvdCongestionControl 1.3.6.1.4.1.123.3.82.1.4.1.4
Congestion Control for VS/VD endpoints, also known as Closed Loop Congestion Control (CLCC).
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncCrSpvccDstCfgLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.4.1.5
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncCrSpvccDstCfgRowStatus 1.3.6.1.4.1.123.3.82.1.4.1.6
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncFrSpvcTable 1.3.6.1.4.1.123.3.82.1.5
nncFrSpvcTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query FR SPVCCs.
OBJECT-TYPE    
  SEQUENCE OF  
    NncFrSpvcTableEntry

nncFrSpvcTableEntry 1.3.6.1.4.1.123.3.82.1.5.1
An entry of nncFrSpvcTable.
OBJECT-TYPE    
  NncFrSpvcTableEntry  

nncFrSpvcSrcDlci 1.3.6.1.4.1.123.3.82.1.5.1.1
This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the source endpoint, and has only local significance to the specified link. Range: 16 - 1023
OBJECT-TYPE    
  INTEGER 16..1023  

nncFrSpvcTargEpAddr 1.3.6.1.4.1.123.3.82.1.5.1.2
This object contains the target endpoint's 20-byte ATM End System Address (AESA) proposed by ATM Forum. An endpoint address is created by appending the switch-wide 13-byte Internal Switch Subscriber Address Prefix with a 6-byte End Station Identifier (ESI) followed by a selector byte. The ESI is in IEEE MAC address format and the exact form depends upon the destination endpoint and the SPVC commissioning method. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag1| Port | Circuit | ------------------------------------------------------------------------ 20th byte |Circuit(continued) | Stream | ------------------------------------------------------------------------
OBJECT-TYPE    
  AtmFormatDisplay  

nncFrSpvcTargDlci 1.3.6.1.4.1.123.3.82.1.5.1.3
This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the target endpoint, and has only local significance to the specified link. Range: 16 - 1023
OBJECT-TYPE    
  INTEGER 16..1023  

nncFrSpvcTargVpi 1.3.6.1.4.1.123.3.82.1.5.1.4
This object contains the virtual path identifier (VPI) value for the Cell Relay based target endpoint. Range: 0 - 4095
OBJECT-TYPE    
  INTEGER 0..4095  

nncFrSpvcTargVci 1.3.6.1.4.1.123.3.82.1.5.1.5
This object contains the virtual channel identifier (VCI) value for the cell-relay based target endpoint. Range: 1 - 65535
OBJECT-TYPE    
  INTEGER 1..65535  

nncFrSpvcTargEpType 1.3.6.1.4.1.123.3.82.1.5.1.6
This object specifies a target endpoint as one of the following types: cellRelay (1) frameRelay (2)
OBJECT-TYPE    
  INTEGER cellRelay(1), frameRelay(2)  

nncFrSpvcAdminStatus 1.3.6.1.4.1.123.3.82.1.5.1.7
This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncFrSpvcAdminStatus to determine if the connection is successful.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nncFrSpvcPriority 1.3.6.1.4.1.123.3.82.1.5.1.8
This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16
OBJECT-TYPE    
  INTEGER 1..16  

nncFrSpvcMaxAdminWeight 1.3.6.1.4.1.123.3.82.1.5.1.9
This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647
OBJECT-TYPE    
  Integer32 -1..2147483647  

nncFrSpvcOperation 1.3.6.1.4.1.123.3.82.1.5.1.10
This object is used to request a reroute operation. Querying this object will not provide any useful information.
OBJECT-TYPE    
  INTEGER reRouteDualEp(7)  

nncFrSpvcCallStatus 1.3.6.1.4.1.123.3.82.1.5.1.11
This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'.
OBJECT-TYPE    
  INTEGER connected(2), waitingForResources(4), readyToConnect(7)  

nncFrSpvcLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.5.1.12
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncFrSpvcSrcBillingFlag 1.3.6.1.4.1.123.3.82.1.5.1.13
Billing Configuration for the source endpoint.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcFrPriority 1.3.6.1.4.1.123.3.82.1.5.1.14
Frame Relay Priority.
OBJECT-TYPE    
  INTEGER bestEffort(1), committedThroughput(2), lowLatency(3), realTime(4)  

nncFrSpvcFrVsvdCongestionControl 1.3.6.1.4.1.123.3.82.1.5.1.15
Congestion Control for VS/VD endpoints, also known as Closed Loop Congestion Control (CLCC).
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcFwdFrMir 1.3.6.1.4.1.123.3.82.1.5.1.16
The FR Src->Dst Minimum Information Rate, used to set the minimum rate on a CLCC FR-FR SPVC connection. If nncFrSpvcFrVsvdCongestionControl is not enabled, this attribute has no effect. Range: 0 - 44210 Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcFwdTmAr 1.3.6.1.4.1.123.3.82.1.5.1.17
This object is used to specify the Access Rate, in Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcFwdTmCir 1.3.6.1.4.1.123.3.82.1.5.1.18
The committed Information Rate, in Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcFwdTmBc 1.3.6.1.4.1.123.3.82.1.5.1.19
The Committed Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcFwdTmBe 1.3.6.1.4.1.123.3.82.1.5.1.20
Excess Burst Size, Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcTmIwf 1.3.6.1.4.1.123.3.82.1.5.1.21
Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4)
OBJECT-TYPE    
  INTEGER none(0), networkInterworking(2), serviceInterworking(3), fFwdInterworking(4)  

nncFrSpvcFwdTmPo 1.3.6.1.4.1.123.3.82.1.5.1.22
Policing.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(3)  

nncFrSpvcFwdTmPacing 1.3.6.1.4.1.123.3.82.1.5.1.23
Pacing.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcTmPtclMapping 1.3.6.1.4.1.123.3.82.1.5.1.24
Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmSIWProfile. Values: transparent (0), translated (1) (see also nncFrSpvcTmSIWProfile)
OBJECT-TYPE    
  INTEGER transparent(0), translated(1)  

nncFrSpvcTmClpMapping 1.3.6.1.4.1.123.3.82.1.5.1.25
Cell Loss Priority Mapping, for use in FR-CR interworking SPVCs. Values: cLPEqualsDE (CLP = DE, 0) cLPEquals0 (CLP = 0, 1 ) cLPEquals1 (CLP = 1, 2 )
OBJECT-TYPE    
  INTEGER cLPEqualsDE(0), cLPEquals0(1), cLPEquals1(2)  

nncFrSpvcTmDeMapping 1.3.6.1.4.1.123.3.82.1.5.1.26
Discard Eligibility Mapping, for use in FR-CR interworking SPVCs. Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking.
OBJECT-TYPE    
  INTEGER dEEqualsCLP(0), dESSCSor0(1), dEEquals1(2)  

nncFrSpvcTmEfciMapping 1.3.6.1.4.1.123.3.82.1.5.1.27
Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (EFCI = FECN, 0) eFCIEquals0 (EFCI = 0, 1)
OBJECT-TYPE    
  INTEGER eFCIEqualsFECN(0), eFCIEquals0(1)  

nncFrSpvcTmPvcMgntProfile 1.3.6.1.4.1.123.3.82.1.5.1.28
Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected.
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

nncFrSpvcTmSIWProfile 1.3.6.1.4.1.123.3.82.1.5.1.29
The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attributes nncFrSpvcTmIwf and nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 - 16.
OBJECT-TYPE    
  INTEGER 1..16  

nncFrSpvcTmRemapDlci 1.3.6.1.4.1.123.3.82.1.5.1.30
The source end-point Data Link Connection Identifier for many-to-one Network Interworking (IWF2) connections.
OBJECT-TYPE    
  INTEGER 16..1023  

nncFrSpvcBwdFrMir 1.3.6.1.4.1.123.3.82.1.5.1.31
The FR Dst->Src Minimum Information Rate, used on CLCC-enabled connections. Range: 0 - 44210 Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcBwdTmAr 1.3.6.1.4.1.123.3.82.1.5.1.32
This object is used to specify the Access Rate, in Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcBwdTmCir 1.3.6.1.4.1.123.3.82.1.5.1.33
The committed Information Rate, in Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcBwdTmBc 1.3.6.1.4.1.123.3.82.1.5.1.34
The Committed Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcBwdTmBe 1.3.6.1.4.1.123.3.82.1.5.1.35
The Excess Burst Size, Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcBwdTmPo 1.3.6.1.4.1.123.3.82.1.5.1.36
Policing.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(3)  

nncFrSpvcBwdTmPacing 1.3.6.1.4.1.123.3.82.1.5.1.37
Pacing.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcCrTmServiceCategory 1.3.6.1.4.1.123.3.82.1.5.1.38
This object is used to set the traffic service category for SPVC Connections. This object is dependent on the value specified in nncFrSpvcCrBwdTmTrafficDescriptor.
OBJECT-TYPE    
  INTEGER nrtvbr(2), abr(3), ubr(4), rtvbr(6)  

nncFrSpvcCrBwdTmTrafficDescriptor 1.3.6.1.4.1.123.3.82.1.5.1.39
This object contains the CR traffic descriptor for a FR-CR SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only)
OBJECT-TYPE    
  INTEGER tagAll(1), p0Plus1SlashS0Plus1(3), p0Plus1SlashS0(4), p0Plus1SlashM0Plus1(5)  

nncFrSpvcCrBwdTmPolicingOption 1.3.6.1.4.1.123.3.82.1.5.1.40
Policing Option for a FR SPVC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor
OBJECT-TYPE    
  INTEGER disabled(1), tag(2), discard(3)  

nncFrSpvcCrBwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.5.1.41
Used in FR - CR interworking. This object is for peak cell rate (PCR), the cell rate which the cell endpoint may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncFrSpvcCrBwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.5.1.42
This object is used to set cell delay variation tolerance (CDVT) for the CR endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncFrSpvcCrBwdTmBucketTwoRate 1.3.6.1.4.1.123.3.82.1.5.1.43
Used in FR - CR interworking. The attribute contains the SIR_0, SIR_0+1 or MIR_0+1. This parameter holds the sustained information rate (SIR_0 or SIR_0+1) for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s
OBJECT-TYPE    
  INTEGER 0..2488320  

nncFrSpvcCrBwdTmBucketTwoMbs 1.3.6.1.4.1.123.3.82.1.5.1.44
This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells
OBJECT-TYPE    
  INTEGER 1..10000  

nncFrSpvcCrBwdTmCdv 1.3.6.1.4.1.123.3.82.1.5.1.45
This value is to set the cell delay variation (CDV) at the CR endpoint. Applicable only when the rt-VBR service category is used. Range: 250-10000 microseconds
OBJECT-TYPE    
  INTEGER 250..10000  

nncFrSpvcCrBwdTmClr 1.3.6.1.4.1.123.3.82.1.5.1.46
The object is to set the cell loss ratio (CLR) at the CR endpoint of a FR-CR SPVC. Valid only when using the nrt-VBR service category. Value set as 1.0e-#
OBJECT-TYPE    
  INTEGER 1..7  

nncFrSpvcCrBwdTmFrameDiscard 1.3.6.1.4.1.123.3.82.1.5.1.47
The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcCreator 1.3.6.1.4.1.123.3.82.1.5.1.48
The object retrieves the creator of a given SPVC connection.
OBJECT-TYPE    
  INTEGER unknown(0), nmti(1), nm5620(2), snmp(9)  

nncFrSpvcRowStatus 1.3.6.1.4.1.123.3.82.1.5.1.49
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncFrSpvcDstCfgTable 1.3.6.1.4.1.123.3.82.1.6
the nncFrSpvcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms.
OBJECT-TYPE    
  SEQUENCE OF  
    NncFrSpvcDstCfgTableEntry

nncFrSpvcDstCfgTableEntry 1.3.6.1.4.1.123.3.82.1.6.1
An entry of nncFrSpvcDstCfgTable.
OBJECT-TYPE    
  NncFrSpvcDstCfgTableEntry  

nncFrSpvcDstCfgTmAr 1.3.6.1.4.1.123.3.82.1.6.1.1
This object is used to specify the Access Rate, in Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcDstCfgTmCir 1.3.6.1.4.1.123.3.82.1.6.1.2
The committed Information Rate, Kb/s
OBJECT-TYPE    
  INTEGER 0..44210  

nncFrSpvcDstCfgTmBc 1.3.6.1.4.1.123.3.82.1.6.1.3
The Committed Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcDstCfgTmBe 1.3.6.1.4.1.123.3.82.1.6.1.4
Excess Burst Size, in Kb.
OBJECT-TYPE    
  INTEGER 0..2097151  

nncFrSpvcDstCfgTmIwf 1.3.6.1.4.1.123.3.82.1.6.1.5
Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4)
OBJECT-TYPE    
  INTEGER none(0), networkInterworking(2), serviceInterworking(3), fFwdInterworking(4)  

nncFrSpvcDstCfgTmPo 1.3.6.1.4.1.123.3.82.1.6.1.6
Policing.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(3)  

nncFrSpvcDstCfgTmPacing 1.3.6.1.4.1.123.3.82.1.6.1.7
Pacing.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcDstCfgTmPtclMapping 1.3.6.1.4.1.123.3.82.1.6.1.8
Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmPvcMgntProfile.
OBJECT-TYPE    
  INTEGER transparent(0), translated(1)  

nncFrSpvcDstCfgTmClpMapping 1.3.6.1.4.1.123.3.82.1.6.1.9
Cell Loss Priority Mapping. Values: cLPEqualsDE (CLP = DE) cLPEquals0 (CLP = 0 ) cLPEquals1 (CLP = 1 )
OBJECT-TYPE    
  INTEGER cLPEqualsDE(0), cLPEquals0(1), cLPEquals1(2)  

nncFrSpvcDstCfgTmDeMapping 1.3.6.1.4.1.123.3.82.1.6.1.10
Discard Eligibility Mapping Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking.
OBJECT-TYPE    
  INTEGER dEEqualsCLP(0), dESSCSor0(1), dEEquals1(2)  

nncFrSpvcDstCfgTmEfciMapping 1.3.6.1.4.1.123.3.82.1.6.1.11
Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (0) eFCIEquals0 (1)
OBJECT-TYPE    
  INTEGER eFCIEqualsFECN(0), eFCIEquals0(1)  

nncFrSpvcDstCfgTmPvcMgntProfile 1.3.6.1.4.1.123.3.82.1.6.1.12
Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected.
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

nncFrSpvcDstCfgTmSIWProfile 1.3.6.1.4.1.123.3.82.1.6.1.13
The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attribute nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 = 16.
OBJECT-TYPE    
  INTEGER 1..16  

nncFrSpvcDstCfgTmRemapDlci 1.3.6.1.4.1.123.3.82.1.6.1.14
The source end-point Data Link Connection Identifier for many-to-one Network Interworking (IWF2) connections.
OBJECT-TYPE    
  INTEGER 16..1023  

nncFrSpvcDstCfgBillingFlag 1.3.6.1.4.1.123.3.82.1.6.1.15
Billing Configuration for the destination endpoint.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

nncFrSpvcDstCfgFrPriority 1.3.6.1.4.1.123.3.82.1.6.1.16
Frame Relay Priority.
OBJECT-TYPE    
  INTEGER bestEffort(1), committedThroughput(2), lowLatency(3), realTime(4)  

nncFrSpvcDstCfgLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.6.1.17
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledUniSide(2), enabledNniSide(3)  

nncFrSpvcDstCfgRowStatus 1.3.6.1.4.1.123.3.82.1.6.1.18
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncCeSpvcTable 1.3.6.1.4.1.123.3.82.1.7
nncCeSpvcTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query CE SPVCCs. The table is indexed using ifIndex, which includes the circuit number field.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCeSpvcTableEntry

nncCeSpvcTableEntry 1.3.6.1.4.1.123.3.82.1.7.1
An entry of nncCeSpvcTable.
OBJECT-TYPE    
  NncCeSpvcTableEntry  

nncCeSpvcTargEpAddr 1.3.6.1.4.1.123.3.82.1.7.1.1
This object is used to specify the AESA address of the target endpoint. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | Not used, default 0 | ------------------------------------------------------------------------
OBJECT-TYPE    
  AtmFormatDisplay  

nncCeSpvcTargVpi 1.3.6.1.4.1.123.3.82.1.7.1.2
This object contains the virtual path identifier (VPI) value for the target endpoint. Used in interworking CE to CR connections when nncCeSpvcTargEpType configured as cellRelay(1). Range: 0 - 4095
OBJECT-TYPE    
  INTEGER 0..4095  

nncCeSpvcTargVci 1.3.6.1.4.1.123.3.82.1.7.1.3
This object contains the virtual channel identifier (VCI) value for the target endpoint. Used in interworking CE to CR connections when nncCeSpvcTargEpType configured as cellRelay(1). Range: 1 - 65535
OBJECT-TYPE    
  INTEGER 1..65535  

nncCeSpvcTargCeNumber 1.3.6.1.4.1.123.3.82.1.7.1.4
This object contains circuit number, channel group number or both for the Circuit Emulation endpoint. Used in CE to CE connections when nncCrSpvccTargEpType is configured as circuitEmulation(3). For CE connections on unchannelized DS3_CCE card, it's the circuit number 1-28 for UDT circuit number For CE connections on unchannelized E3_CCE card, it's the circuit number 1-16 for UDT circuit number For CE connections on E1/T1 CES, it's channel group number. 0 for UDT mode, both T1 and E1 1-31 for E1 in SDT mode 1-24 for T1 in SDT mode For CE connections on channelized DS3_CCE-2 card, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 28 for channelized DS3, = 0 for unstructured DS3) channelGroupNum (bits 1-8, = 1 to 24 for SDT mode, = 0 for UDT Mode) For CE connections on channelized E3_CCE-2, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 16) channelGroupNum (bits 1-8, = 1 to 31 for SDT mode, = 0 for UDT Mode) Example: Circuit Number = 7, Channel Group = 3 : nncCrSpvccTargCeNumber = (Circuit Number * 256) + Channel Group = 1795 SPVCs across service types other than circuit emulation do not require this object.
OBJECT-TYPE    
  INTEGER 0..65535  

nncCeSpvcTargEpType 1.3.6.1.4.1.123.3.82.1.7.1.5
This object specifies a target endpoint as one of the following types: cellRelay (1) circuitEmulation (3)
OBJECT-TYPE    
  INTEGER cellRelay(1), circuitEmulation(3)  

nncCeSpvcAdminStatus 1.3.6.1.4.1.123.3.82.1.7.1.6
This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCeSpvcAdminStatus to determine if the connection is successful.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nncCeSpvcPriority 1.3.6.1.4.1.123.3.82.1.7.1.7
This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16
OBJECT-TYPE    
  INTEGER 1..16  

nncCeSpvcMaxAdminWeight 1.3.6.1.4.1.123.3.82.1.7.1.8
This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647
OBJECT-TYPE    
  Integer32 -1..2147483647  

nncCeSpvcOperation 1.3.6.1.4.1.123.3.82.1.7.1.9
This object is used to request a reroute operation. Querying this object will not provide any useful information.
OBJECT-TYPE    
  INTEGER reRouteDualEp(7)  

nncCeSpvcCallStatus 1.3.6.1.4.1.123.3.82.1.7.1.10
This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'.
OBJECT-TYPE    
  INTEGER connected(2), waitingForResources(4), readyToConnect(7)  

nncCeSpvcLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.7.1.11
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. For circuit emulation UNI side is not supported. It can be configured for either NNI side or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledNniSide(3)  

nncCeSpvcFwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.7.1.12
This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s For N x DS0 SDT Basic connections = ((((1 + 1.0 / 128) * 8 * N / K) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 1..47 is the number of data octets per cell. For N x DS0 SDT CAS connections = ((((1 + 1.0 / 128) * 8 * (((Cn * N) + (N % 2)) / (Ck * K))) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 2..47 is the number of data octets per cell. Cn = 49 for T1 Cn = 33 for E1 Ck = 48 for T1 Ck = 32 for E1 = 1755 Kb/s for T1,DS1 UDT connections = 2328 Kb/s for E1 UDT connections = 50842 Kb/s for DS3 UDT connections
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCeSpvcFwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.7.1.13
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCeSpvcBwdTmBucketOneRate 1.3.6.1.4.1.123.3.82.1.7.1.14
This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s For N x DS0 SDT Basic connections = ((((1 + 1.0 / 128) * 8 * N / K) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 1..47 is the number of data octets per cell. For N x DS0 SDT CAS connections = ((((1 + 1.0 / 128) * 8 * (((Cn * N) + (N % 2)) / (Ck * K))) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 2..47 is the number of data octets per cell. Cn = 49 for T1 Cn = 33 for E1 Ck = 48 for T1 Ck = 32 for E1 = 1755 Kb/s for T1,DS1 UDT connections = 2328 Kb/s for E1 UDT connections = 50842 Kb/s for DS3 UDT connections
OBJECT-TYPE    
  INTEGER 0..2488320  

nncCeSpvcBwdTmBucketOneCdvt 1.3.6.1.4.1.123.3.82.1.7.1.15
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCeSpvcCreator 1.3.6.1.4.1.123.3.82.1.7.1.16
The object retrieves the creator of a SPVC connection.
OBJECT-TYPE    
  INTEGER unknown(0), nmti(1), nm5620(2), snmp(9)  

nncCeSpvcRowStatus 1.3.6.1.4.1.123.3.82.1.7.1.17
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncCeSpvcDstCfgTable 1.3.6.1.4.1.123.3.82.1.8
the nncCeSpvcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms.
OBJECT-TYPE    
  SEQUENCE OF  
    NncCeSpvcDstCfgTableEntry

nncCeSpvcDstCfgTableEntry 1.3.6.1.4.1.123.3.82.1.8.1
An entry of nncCeSpvcDstCfgTable.
OBJECT-TYPE    
  NncCeSpvcDstCfgTableEntry  

nncCeSpvcDstCfgCdvt 1.3.6.1.4.1.123.3.82.1.8.1.1
This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds
OBJECT-TYPE    
  INTEGER 1..190000  

nncCeSpvcDstCfgLocRerouteConfig 1.3.6.1.4.1.123.3.82.1.8.1.2
This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. For circuit emulation UNI side is not supported. It can be configured for either NNI side or disabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabledNniSide(3)  

nncCeSpvcDstCfgRowStatus 1.3.6.1.4.1.123.3.82.1.8.1.3
This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy'
OBJECT-TYPE    
  RowStatus  

nncExtSpvcGroups 1.3.6.1.4.1.123.3.82.3
OBJECT IDENTIFIER    

nncCrSpvpcGroup 1.3.6.1.4.1.123.3.82.3.1
Common MIB objects for configuring a CR SPVPC source end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncCrSpvpcDstCfgGroup 1.3.6.1.4.1.123.3.82.3.2
Common MIB objects for configuring a Cell Relay SPVPC destination end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncCrSpvccGroup 1.3.6.1.4.1.123.3.82.3.3
Common MIB objects for configuring a CR SPVC source end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncCrSpvccDstCfgGroup 1.3.6.1.4.1.123.3.82.3.4
Common MIB objects for configuring a Cell Relay SPVC destination end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncFrSpvcGroup 1.3.6.1.4.1.123.3.82.3.5
Common MIB objects for configuring an SPVC using a Frame Relay source end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncFrSpvcDstCfgGroup 1.3.6.1.4.1.123.3.82.3.6
Common MIB objects for configuring a Frame-Relay SPVC destination end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncCeSpvcGroup 1.3.6.1.4.1.123.3.82.3.7
Common MIB objects for configuring a Circuit Emulation-based SPVC source end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncCeSpvcDstCfgGroup 1.3.6.1.4.1.123.3.82.3.8
Common MIB objects for configuring a Circuit Emulation SPVC destination end-point across all Alcatel CID ATM platforms.
OBJECT-GROUP    

nncExtSpvcCompliances 1.3.6.1.4.1.123.3.82.4
OBJECT IDENTIFIER    

nncSpvcCompliance 1.3.6.1.4.1.123.3.82.4.1
The compliance statement for Alcatel CID SPVC MIB implementation.
MODULE-COMPLIANCE    

Defined Objects

AtmFormatDisplay  
This display is for the ATM address prefix format. The following formats which are supported are displayed: DCC ATM Format ------------------------------------------------------------- |A | | | | | | | | | | | | | | | | | | | S| |F | DCC | HO-DSP | ESI | E| |I | | | | | | | | | | | | | | | | | | | L| ------------------------------------------------------------- |...IDP..|......................DSP.........................| |.IDI.| ICD ATM Format ------------------------------------------------------------- |A | | | | | | | | | | | | | | | | | | | S| |F | ICD | HO-DSP | ESI | E| |I | | | | | | | | | | | | | | | | | | | L| ------------------------------------------------------------- |...IDP..|......................DSP.........................| |.IDI.| For the DCC ATM Format, the following format will be displayed: afi-dcc-hodsp-esi-sel For the ICD ATM Format, the following format will be displayed: afi-icd-hodsp-esi-sel Abbreviations: IDP: Initial Domain Part AFI: Authority and Format Identifier IDI: Initial Domain Part DCC: Data Country Code ICD: International Code Designator DSP: Domain Specific Part HO-DSP: The coding of this field is specified by the authority or the coding scheme identified by the IDP. ESI: End System Identifier SEL: Selector
TEXTUAL-CONVENTION    
  OCTET STRING SIZE(20)  

NncCrSpvpcTableEntry  
SEQUENCE    
  INTEGER as nncCrSpvpcServiceCategory  
  AtmFormatDisplay as nncCrSpvpcTargEpAddr  
  INTEGER as nncCrSpvpcTargVpi  
  INTEGER as nncCrSpvpcAdminStatus  
  INTEGER as nncCrSpvpcPriority  
  Integer32 as nncCrSpvpcMaxAdminWeight  
  INTEGER as nncCrSpvpcOperation  
  INTEGER as nncCrSpvpcCallStatus  
  INTEGER as nncCrSpvpcLocRerouteConfig  
  INTEGER as nncCrSpvpcFwdAbrDynTrfcIcr  
  INTEGER as nncCrSpvpcFwdAbrDynTrfcRif  
  INTEGER as nncCrSpvpcFwdAbrDynTrfcRdf  
  INTEGER as nncCrSpvpcBwdAbrDynTrfcIcr  
  INTEGER as nncCrSpvpcBwdAbrDynTrfcRif  
  INTEGER as nncCrSpvpcBwdAbrDynTrfcRdf  
  INTEGER as nncCrSpvpcSrcBillingFlag  
  INTEGER as nncCrSpvpcFwdTmTrafficDescriptor  
  INTEGER as nncCrSpvpcFwdTmPolicingOption  
  INTEGER as nncCrSpvpcFwdTmBucketOneRate  
  INTEGER as nncCrSpvpcFwdTmBucketOneCdvt  
  INTEGER as nncCrSpvpcFwdTmBucketTwoRate  
  INTEGER as nncCrSpvpcFwdTmBucketTwoMbs  
  INTEGER as nncCrSpvpcFwdTmCdv  
  INTEGER as nncCrSpvpcFwdTmClr  
  INTEGER as nncCrSpvpcBwdTmTrafficDescriptor  
  INTEGER as nncCrSpvpcBwdTmPolicingOption  
  INTEGER as nncCrSpvpcBwdTmBucketOneRate  
  INTEGER as nncCrSpvpcBwdTmBucketOneCdvt  
  INTEGER as nncCrSpvpcBwdTmBucketTwoRate  
  INTEGER as nncCrSpvpcBwdTmBucketTwoMbs  
  INTEGER as nncCrSpvpcBwdTmCdv  
  INTEGER as nncCrSpvpcBwdTmClr  
  INTEGER as nncCrSpvpcCreator  
  RowStatus as nncCrSpvpcRowStatus  

NncCrSpvpcDstCfgTableEntry  
SEQUENCE    
  INTEGER as nncCrSpvpcDstCfgCdvt  
  INTEGER as nncCrSpvpcDstCfgPolicing  
  INTEGER as nncCrSpvpcDstCfgBillingFlag  
  INTEGER as nncCrSpvpcDstCfgLocRerouteConfig  
  RowStatus as nncCrSpvpcDstCfgRowStatus  

NncCrSpvccTableEntry  
SEQUENCE    
  INTEGER as nncCrSpvccServiceCategory  
  AtmFormatDisplay as nncCrSpvccTargEpAddr  
  INTEGER as nncCrSpvccTargVpi  
  INTEGER as nncCrSpvccTargVci  
  INTEGER as nncCrSpvccTargDlci  
  INTEGER as nncCrSpvccTargCeNumber  
  INTEGER as nncCrSpvccTargEpType  
  INTEGER as nncCrSpvccAdminStatus  
  INTEGER as nncCrSpvccPriority  
  Integer32 as nncCrSpvccMaxAdminWeight  
  INTEGER as nncCrSpvccOperation  
  INTEGER as nncCrSpvccCallStatus  
  INTEGER as nncCrSpvccLocRerouteConfig  
  INTEGER as nncCrSpvccFwdAbrDynTrfcIcr  
  INTEGER as nncCrSpvccFwdAbrDynTrfcRif  
  INTEGER as nncCrSpvccFwdAbrDynTrfcRdf  
  INTEGER as nncCrSpvccBwdAbrDynTrfcIcr  
  INTEGER as nncCrSpvccBwdAbrDynTrfcRif  
  INTEGER as nncCrSpvccBwdAbrDynTrfcRdf  
  INTEGER as nncCrSpvccSrcBillingFlag  
  INTEGER as nncCrSpvccFwdTmTrafficDescriptor  
  INTEGER as nncCrSpvccFwdTmPolicingOption  
  INTEGER as nncCrSpvccFwdTmBucketOneRate  
  INTEGER as nncCrSpvccFwdTmBucketOneCdvt  
  INTEGER as nncCrSpvccFwdTmBucketTwoRate  
  INTEGER as nncCrSpvccFwdTmBucketTwoMbs  
  INTEGER as nncCrSpvccFwdTmCdv  
  INTEGER as nncCrSpvccFwdTmClr  
  INTEGER as nncCrSpvccFwdTmFrameDiscard  
  INTEGER as nncCrSpvccBwdTmTrafficDescriptor  
  INTEGER as nncCrSpvccBwdTmPolicingOption  
  INTEGER as nncCrSpvccBwdTmBucketOneRate  
  INTEGER as nncCrSpvccBwdTmBucketOneCdvt  
  INTEGER as nncCrSpvccBwdTmBucketTwoRate  
  INTEGER as nncCrSpvccBwdTmBucketTwoMbs  
  INTEGER as nncCrSpvccBwdTmCdv  
  INTEGER as nncCrSpvccBwdTmClr  
  INTEGER as nncCrSpvccBwdTmFrameDiscard  
  INTEGER as nncCrSpvccFrBwdTmAr  
  INTEGER as nncCrSpvccFrBwdTmCir  
  INTEGER as nncCrSpvccFrBwdTmBc  
  INTEGER as nncCrSpvccFrBwdTmBe  
  INTEGER as nncCrSpvccFrBwdTmIwf  
  INTEGER as nncCrSpvccFrBwdTmPo  
  INTEGER as nncCrSpvccFrBwdTmPacing  
  INTEGER as nncCrSpvccFrBwdTmPtclMapping  
  INTEGER as nncCrSpvccFrBwdTmClpMapping  
  INTEGER as nncCrSpvccFrBwdTmDeMapping  
  INTEGER as nncCrSpvccFrBwdTmEfciMapping  
  INTEGER as nncCrSpvccFrBwdTmPvcMgntProfile  
  INTEGER as nncCrSpvccFrBwdTmSIWProfile  
  INTEGER as nncCrSpvccCreator  
  RowStatus as nncCrSpvccRowStatus  

NncCrSpvccDstCfgTableEntry  
SEQUENCE    
  INTEGER as nncCrSpvccDstCfgCdvt  
  INTEGER as nncCrSpvccDstCfgPolicing  
  INTEGER as nncCrSpvccDstCfgBillingFlag  
  INTEGER as nncCrSpvccDstCfgFrVsvdCongestionControl  
  INTEGER as nncCrSpvccDstCfgLocRerouteConfig  
  RowStatus as nncCrSpvccDstCfgRowStatus  

NncFrSpvcTableEntry  
SEQUENCE    
  INTEGER as nncFrSpvcSrcDlci  
  AtmFormatDisplay as nncFrSpvcTargEpAddr  
  INTEGER as nncFrSpvcTargDlci  
  INTEGER as nncFrSpvcTargVpi  
  INTEGER as nncFrSpvcTargVci  
  INTEGER as nncFrSpvcTargEpType  
  INTEGER as nncFrSpvcAdminStatus  
  INTEGER as nncFrSpvcPriority  
  Integer32 as nncFrSpvcMaxAdminWeight  
  INTEGER as nncFrSpvcOperation  
  INTEGER as nncFrSpvcCallStatus  
  INTEGER as nncFrSpvcLocRerouteConfig  
  INTEGER as nncFrSpvcSrcBillingFlag  
  INTEGER as nncFrSpvcFrPriority  
  INTEGER as nncFrSpvcFrVsvdCongestionControl  
  INTEGER as nncFrSpvcFwdFrMir  
  INTEGER as nncFrSpvcFwdTmAr  
  INTEGER as nncFrSpvcFwdTmCir  
  INTEGER as nncFrSpvcFwdTmBc  
  INTEGER as nncFrSpvcFwdTmBe  
  INTEGER as nncFrSpvcTmIwf  
  INTEGER as nncFrSpvcFwdTmPo  
  INTEGER as nncFrSpvcFwdTmPacing  
  INTEGER as nncFrSpvcTmPtclMapping  
  INTEGER as nncFrSpvcTmClpMapping  
  INTEGER as nncFrSpvcTmDeMapping  
  INTEGER as nncFrSpvcTmEfciMapping  
  INTEGER as nncFrSpvcTmPvcMgntProfile  
  INTEGER as nncFrSpvcTmSIWProfile  
  INTEGER as nncFrSpvcTmRemapDlci  
  INTEGER as nncFrSpvcBwdFrMir  
  INTEGER as nncFrSpvcBwdTmAr  
  INTEGER as nncFrSpvcBwdTmCir  
  INTEGER as nncFrSpvcBwdTmBc  
  INTEGER as nncFrSpvcBwdTmBe  
  INTEGER as nncFrSpvcBwdTmPo  
  INTEGER as nncFrSpvcBwdTmPacing  
  INTEGER as nncFrSpvcCrTmServiceCategory  
  INTEGER as nncFrSpvcCrBwdTmTrafficDescriptor  
  INTEGER as nncFrSpvcCrBwdTmPolicingOption  
  INTEGER as nncFrSpvcCrBwdTmBucketOneRate  
  INTEGER as nncFrSpvcCrBwdTmBucketOneCdvt  
  INTEGER as nncFrSpvcCrBwdTmBucketTwoRate  
  INTEGER as nncFrSpvcCrBwdTmBucketTwoMbs  
  INTEGER as nncFrSpvcCrBwdTmCdv  
  INTEGER as nncFrSpvcCrBwdTmClr  
  INTEGER as nncFrSpvcCrBwdTmFrameDiscard  
  INTEGER as nncFrSpvcCreator  
  RowStatus as nncFrSpvcRowStatus  

NncFrSpvcDstCfgTableEntry  
SEQUENCE    
  INTEGER as nncFrSpvcDstCfgTmAr  
  INTEGER as nncFrSpvcDstCfgTmCir  
  INTEGER as nncFrSpvcDstCfgTmBc  
  INTEGER as nncFrSpvcDstCfgTmBe  
  INTEGER as nncFrSpvcDstCfgTmIwf  
  INTEGER as nncFrSpvcDstCfgTmPo  
  INTEGER as nncFrSpvcDstCfgTmPacing  
  INTEGER as nncFrSpvcDstCfgTmPtclMapping  
  INTEGER as nncFrSpvcDstCfgTmClpMapping  
  INTEGER as nncFrSpvcDstCfgTmDeMapping  
  INTEGER as nncFrSpvcDstCfgTmEfciMapping  
  INTEGER as nncFrSpvcDstCfgTmPvcMgntProfile  
  INTEGER as nncFrSpvcDstCfgTmSIWProfile  
  INTEGER as nncFrSpvcDstCfgTmRemapDlci  
  INTEGER as nncFrSpvcDstCfgBillingFlag  
  INTEGER as nncFrSpvcDstCfgFrPriority  
  INTEGER as nncFrSpvcDstCfgLocRerouteConfig  
  RowStatus as nncFrSpvcDstCfgRowStatus  

NncCeSpvcTableEntry  
SEQUENCE    
  AtmFormatDisplay as nncCeSpvcTargEpAddr  
  INTEGER as nncCeSpvcTargVpi  
  INTEGER as nncCeSpvcTargVci  
  INTEGER as nncCeSpvcTargCeNumber  
  INTEGER as nncCeSpvcTargEpType  
  INTEGER as nncCeSpvcAdminStatus  
  INTEGER as nncCeSpvcPriority  
  Integer32 as nncCeSpvcMaxAdminWeight  
  INTEGER as nncCeSpvcOperation  
  INTEGER as nncCeSpvcCallStatus  
  INTEGER as nncCeSpvcLocRerouteConfig  
  INTEGER as nncCeSpvcFwdTmBucketOneRate  
  INTEGER as nncCeSpvcFwdTmBucketOneCdvt  
  INTEGER as nncCeSpvcBwdTmBucketOneRate  
  INTEGER as nncCeSpvcBwdTmBucketOneCdvt  
  INTEGER as nncCeSpvcCreator  
  RowStatus as nncCeSpvcRowStatus  

NncCeSpvcDstCfgTableEntry  
SEQUENCE    
  INTEGER as nncCeSpvcDstCfgCdvt  
  INTEGER as nncCeSpvcDstCfgLocRerouteConfig  