
| RFC1155-SMI | RFC-1212 | NOVELL-IPX-MIB |
| RFC1213-MIB |
| enterprises | Counter | OBJECT-TYPE |
| mibDoc | PhysAddress |
| ripsap | 1.3.6.1.4.1.23.2.20 | ||
| OBJECT IDENTIFIER | |||
| ripsapSystem | 1.3.6.1.4.1.23.2.20.1 | ||
| OBJECT IDENTIFIER | |||
| ripSysTable | 1.3.6.1.4.1.23.2.20.1.1 | ||
| The RIP system table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| RIPSysEntry | |||
| ripSysEntry | 1.3.6.1.4.1.23.2.20.1.1.1 | ||
| Each entry corresponds to one instance of RIP running on the system. | |||
| OBJECT-TYPE | |||
| RIPSysEntry | |||
| ripSysInstance | 1.3.6.1.4.1.23.2.20.1.1.1.1 | ||
| The unique identifier of the instance of RIP to which this row corresponds. This value links the instance of RIP to an instance of IPX running on the system (i.e. the value of ripSysInstance should be the same as a value of ipxSysInstance). This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripSysState | 1.3.6.1.4.1.23.2.20.1.1.1.2 | ||
| Indicates the operational state of this instance of RIP. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| ripSysIncorrectPackets | 1.3.6.1.4.1.23.2.20.1.1.1.3 | ||
| The number of times that an incorrectly formatted RIP packet was received. | |||
| OBJECT-TYPE | |||
| Counter | |||
| sapSysTable | 1.3.6.1.4.1.23.2.20.1.2 | ||
| The SAP system table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| SAPSysEntry | |||
| sapSysEntry | 1.3.6.1.4.1.23.2.20.1.2.1 | ||
| Each entry corresponds to one instance of SAP running on the system. | |||
| OBJECT-TYPE | |||
| SAPSysEntry | |||
| sapSysInstance | 1.3.6.1.4.1.23.2.20.1.2.1.1 | ||
| The unique identifier of the instance of SAP to which this row corresponds. This value links the instance of SAP to an instance of IPX running on the system (i.e. the value of SApSysInstance should be the same as a value of ipxSysInstance). This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapSysState | 1.3.6.1.4.1.23.2.20.1.2.1.2 | ||
| Indicates the operational state of this instance of SAP. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| sapSysIncorrectPackets | 1.3.6.1.4.1.23.2.20.1.2.1.3 | ||
| The number of times that an incorrectly formatted SAP packet was received. | |||
| OBJECT-TYPE | |||
| Counter | |||
| ripsapCircuit | 1.3.6.1.4.1.23.2.20.2 | ||
| OBJECT IDENTIFIER | |||
| ripCircTable | 1.3.6.1.4.1.23.2.20.2.1 | ||
| The RIP Circuit table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| RIPCircEntry | |||
| ripCircEntry | 1.3.6.1.4.1.23.2.20.2.1.1 | ||
| Each entry corresponds to one circuit known to the system. | |||
| OBJECT-TYPE | |||
| RIPCircEntry | |||
| ripCircSysInstance | 1.3.6.1.4.1.23.2.20.2.1.1.1 | ||
| The unique identifier of the instance of RIP and IPX (via ipxSysInstance) to which this entry corresponds. This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircIndex | 1.3.6.1.4.1.23.2.20.2.1.1.2 | ||
| The identifier of this circuit, unique within the instance of RIP. This value corresponds to the circuit identifier found in ipxCircIndex. This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircState | 1.3.6.1.4.1.23.2.20.2.1.1.3 | ||
| Indicates whether RIP information may be sent/received over this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), auto-on(3), auto-off(4) | ||
| ripCircPace | 1.3.6.1.4.1.23.2.20.2.1.1.4 | ||
| The maximum pace, in packets per second, at which RIP packets may be sent on this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircUpdate | 1.3.6.1.4.1.23.2.20.2.1.1.5 | ||
| The RIP periodic update interval, in seconds. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircAgeMultiplier | 1.3.6.1.4.1.23.2.20.2.1.1.6 | ||
| The holding multiplier for information received in RIP periodic updates. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircPacketSize | 1.3.6.1.4.1.23.2.20.2.1.1.7 | ||
| The RIP packet size used on this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| ripCircOutPackets | 1.3.6.1.4.1.23.2.20.2.1.1.8 | ||
| The number of RIP packets sent on this circuit. | |||
| OBJECT-TYPE | |||
| Counter | |||
| ripCircInPackets | 1.3.6.1.4.1.23.2.20.2.1.1.9 | ||
| The number of RIP packets received on this circuit. | |||
| OBJECT-TYPE | |||
| Counter | |||
| sapCircTable | 1.3.6.1.4.1.23.2.20.2.2 | ||
| The SAP Circuit table. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| SAPCircEntry | |||
| sapCircEntry | 1.3.6.1.4.1.23.2.20.2.2.1 | ||
| Each entry corresponds to one circuit known to the system. | |||
| OBJECT-TYPE | |||
| SAPCircEntry | |||
| sapCircSysInstance | 1.3.6.1.4.1.23.2.20.2.2.1.1 | ||
| The unique identifier of the instance of SAP and IPX (via ipxSysInstance) to which this entry corresponds. This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircIndex | 1.3.6.1.4.1.23.2.20.2.2.1.2 | ||
| The identifier of this circuit, unique within the instance of SAP. This value corresponds to the circuit identifier found in ipxCircIndex. This value may be written only when creating a new entry in the table. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircState | 1.3.6.1.4.1.23.2.20.2.2.1.3 | ||
| Indicates whether SAP information may be sent/received over this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), auto-on(3), auto-off(4) | ||
| sapCircPace | 1.3.6.1.4.1.23.2.20.2.2.1.4 | ||
| The maximum pace, in packets per second, at which SAP packets may be sent on this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircUpdate | 1.3.6.1.4.1.23.2.20.2.2.1.5 | ||
| The SAP periodic update interval, in seconds. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircAgeMultiplier | 1.3.6.1.4.1.23.2.20.2.2.1.6 | ||
| The holding multiplier for information received in SAP periodic updates. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircPacketSize | 1.3.6.1.4.1.23.2.20.2.2.1.7 | ||
| The SAP packet size used on this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| sapCircGetNearestServerReply | 1.3.6.1.4.1.23.2.20.2.2.1.8 | ||
| Indicates whether to respond to SAP get nearest server requests received on this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | no(1), yes(2) | ||
| sapCircOutPackets | 1.3.6.1.4.1.23.2.20.2.2.1.9 | ||
| The number of SAP packets sent on this circuit. | |||
| OBJECT-TYPE | |||
| Counter | |||
| sapCircInPackets | 1.3.6.1.4.1.23.2.20.2.2.1.10 | ||
| The number of SAP packets received on this circuit. | |||
| OBJECT-TYPE | |||
| Counter | |||
| RIPSysEntry | |||
| SEQUENCE | |||
| INTEGER as ripSysInstance | |||
| INTEGER as ripSysState | |||
| Counter as ripSysIncorrectPackets | |||
| SAPSysEntry | |||
| SEQUENCE | |||
| INTEGER as sapSysInstance | |||
| INTEGER as sapSysState | |||
| Counter as sapSysIncorrectPackets | |||
| RIPCircEntry | |||
| SEQUENCE | |||
| INTEGER as ripCircSysInstance | |||
| INTEGER as ripCircIndex | |||
| INTEGER as ripCircState | |||
| INTEGER as ripCircPace | |||
| INTEGER as ripCircUpdate | |||
| INTEGER as ripCircAgeMultiplier | |||
| INTEGER as ripCircPacketSize | |||
| Counter as ripCircOutPackets | |||
| Counter as ripCircInPackets | |||
| SAPCircEntry | |||
| SEQUENCE | |||
| INTEGER as sapCircSysInstance | |||
| INTEGER as sapCircIndex | |||
| INTEGER as sapCircState | |||
| INTEGER as sapCircPace | |||
| INTEGER as sapCircUpdate | |||
| INTEGER as sapCircAgeMultiplier | |||
| INTEGER as sapCircPacketSize | |||
| INTEGER as sapCircGetNearestServerReply | |||
| Counter as sapCircOutPackets | |||
| Counter as sapCircInPackets | |||