| RFC-1212 | RFC1213-MIB | CISCO-SMI |
| OBJECT-TYPE | DisplayString | local |
| lenv | 1.3.6.1.4.1.9.2.1 | ||
| OBJECT IDENTIFIER | |||
| envPresent | 1.3.6.1.4.1.9.2.1.77 | ||
| Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt1Descr | 1.3.6.1.4.1.9.2.1.78 | ||
| Description of the test point 1. Typically ambient air or the temperature of air entering the router | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt1Measure | 1.3.6.1.4.1.9.2.1.79 | ||
| Current value of test point 1. Typically a temperature in centigrade. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt2Descr | 1.3.6.1.4.1.9.2.1.80 | ||
| Description of the test point 2. Typically airflow or the temperature of air leaving the router | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt2Measure | 1.3.6.1.4.1.9.2.1.81 | ||
| Current value of test point 2. Typically a temperature in centigrade. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt3Descr | 1.3.6.1.4.1.9.2.1.82 | ||
| Description of the test point 3. Typically +5 volt | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt3Measure | 1.3.6.1.4.1.9.2.1.83 | ||
| Current value of test point 3. Typically the value in millivolts of the +5v supply | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt4Descr | 1.3.6.1.4.1.9.2.1.84 | ||
| Description of the test point 4. Typically +12 volt | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt4Measure | 1.3.6.1.4.1.9.2.1.85 | ||
| Current value of test point 4. Typically the value in millivolts of the +12v supply | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt5Descr | 1.3.6.1.4.1.9.2.1.86 | ||
| Description of the test point 5. Typically -12 volt | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt5Measure | 1.3.6.1.4.1.9.2.1.87 | ||
| Current value of test point 5. Typically the value in millivolts of the -12v supply | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt6Descr | 1.3.6.1.4.1.9.2.1.88 | ||
| Description of the test point 6. Typically -5 volt | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTestPt6Measure | 1.3.6.1.4.1.9.2.1.89 | ||
| Current value of test point 6. Typically the value in millivolts of the -5v supply | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt1MarginVal | 1.3.6.1.4.1.9.2.1.90 | ||
| Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43) | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt2MarginVal | 1.3.6.1.4.1.9.2.1.91 | ||
| Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58) | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt3MarginPercent | 1.3.6.1.4.1.9.2.1.92 | ||
| +/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt4MarginPercent | 1.3.6.1.4.1.9.2.1.93 | ||
| +/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt5MarginPercent | 1.3.6.1.4.1.9.2.1.94 | ||
| +/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt6MarginPercent | 1.3.6.1.4.1.9.2.1.95 | ||
| +/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt1last | 1.3.6.1.4.1.9.2.1.96 | ||
| Value of TestPt1 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt2last | 1.3.6.1.4.1.9.2.1.97 | ||
| Value of TestPt2 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt3last | 1.3.6.1.4.1.9.2.1.98 | ||
| Value of TestPt3 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt4last | 1.3.6.1.4.1.9.2.1.99 | ||
| Value of TestPt4 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt5last | 1.3.6.1.4.1.9.2.1.100 | ||
| Value of TestPt5 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt6last | 1.3.6.1.4.1.9.2.1.101 | ||
| Value of TestPt6 when last shutdown occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| envTestPt1warn | 1.3.6.1.4.1.9.2.1.102 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envTestPt2warn | 1.3.6.1.4.1.9.2.1.103 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envTestPt3warn | 1.3.6.1.4.1.9.2.1.104 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envTestPt4warn | 1.3.6.1.4.1.9.2.1.105 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envTestPt5warn | 1.3.6.1.4.1.9.2.1.106 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envTestPt6warn | 1.3.6.1.4.1.9.2.1.107 | ||
| Is this test point at a warning level? | |||
| OBJECT-TYPE | |||
| INTEGER | warning(1), noWarning(2) | ||
| envFirmVersion | 1.3.6.1.4.1.9.2.1.108 | ||
| Description of Environmental Card firmware | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envTechnicianID | 1.3.6.1.4.1.9.2.1.109 | ||
| Technician ID | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envType | 1.3.6.1.4.1.9.2.1.110 | ||
| The type of environmental card | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envBurnDate | 1.3.6.1.4.1.9.2.1.111 | ||
| The calibration / burn in date | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| envSerialNumber | 1.3.6.1.4.1.9.2.1.112 | ||
| Serial Number of environmental monitor card | |||
| OBJECT-TYPE | |||
| DisplayString | |||