PDN-DIAGNOSTICS-MIB

File: PDN-DIAGNOSTICS-MIB.mib (29783 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB SNMPv2-TC PDN-HEADER-MIB
IF-MIB

Imported symbols

IpAddress OBJECT-TYPE TRAP-TYPE
ifIndex RowStatus DisplayString
AutonomousType pdn-diagnostics ifTestId

Defined Objects

diagTestMIBObjects 1.3.6.1.4.1.1795.2.24.2.16.1
OBJECT IDENTIFIER    

diagIfTest 1.3.6.1.4.1.1795.2.24.2.16.1.1
OBJECT IDENTIFIER    

ifLoopbackTestTable 1.3.6.1.4.1.1795.2.24.2.16.1.1.1
This table contains input and results of a packet loopback test. This table is indexed by ifIndex. This is a interface related test. There can be only one test running per interface. This table should be used in conjunction with ifTestTable(Rfc 1573) with all the semantics of ifTestTable.
OBJECT-TYPE    
  SEQUENCE OF  
    IfLoopbackTestEntry

ifLoopbackTestEntry 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1
An entry containing objects for test input and result for packet loopback test
OBJECT-TYPE    
  IfLoopbackTestEntry  

loopbackTestInputNumCycles 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.1
This object corresponds the number of cycles the test to be run for. One cycle corresponds to a 15 second interval. The default value for this object is 40.
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsPktsSent 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.2
This object corresponds to the number of packets sent
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsPktsRcvdOK 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.3
This object corresponds to the number of packets which were received without any error
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsPktsRcvdErr 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.4
This object corresponds to the number of packets which were received with errors
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsPktsNotRcvd 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.5
This object corresponds to the number of packets which were sent but not received
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsPktErrorRate 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.6
Reflects the error rate of the loopback test. this string will represent a floating point number of the form [ErrRate][eE][+-][ErrRateBase] where ErrRate and ErrRateBase are integers. In Other Words ErrRate * [10^ -ErrRateBase] shown below are example of the values returned. 123456E-5 = 1.23456 344567e-6 = 0.344567
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

loopbackTestResultsErrSecs 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.7
This object corresponds to the number of errored seconds
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsSvrErrSecs 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.8
This object corresponds to the number of severely errored seconds
OBJECT-TYPE    
  INTEGER  

loopbackTestResultsElpTime 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.9
This object corresponds to the number of seconds elapsed since the start of the test.
OBJECT-TYPE    
  INTEGER  

ifBERTObjectsTable 1.3.6.1.4.1.1795.2.24.2.16.1.1.2
This table contains the objects for Bit Error Rate Test. This table is indexed by ifIndex.
OBJECT-TYPE    
  SEQUENCE OF  
    IfBERTObjectsEntry

ifBERTObjectsEntry 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1
An Entry containing objects of BERT.
OBJECT-TYPE    
  IfBERTObjectsEntry  

ifBERTTestDuration 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.1
This object represents the test duration in seconds.
OBJECT-TYPE    
  INTEGER  

ifBERTElapsedTime 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.2
This object represents the elapsed time in seconds.
OBJECT-TYPE    
  INTEGER  

ifBERTDownSyncUP 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.3
This object indicates whether Downstream sync is enabled .
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ifBERTUpSyncUP 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.4
This object indicates whether upstream sync is enabled.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ifBERTSegmentsSent 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.5
This object represents the number of segments sent during the test
OBJECT-TYPE    
  INTEGER  

ifBERTDownMBitsRcvd 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.6
This represents the number of million bits rcvd downstream.
OBJECT-TYPE    
  INTEGER  

ifBERTUpMBitsRcvd 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.7
This represents the number of million bits rcvd upstream.
OBJECT-TYPE    
  INTEGER  

ifBERTDownBitErrDetected 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.8
This represents the number of bit errors detected downstream.
OBJECT-TYPE    
  INTEGER  

ifBERTUpBitErrDetected 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.9
This represents the number of bit errors detected upstream.
OBJECT-TYPE    
  INTEGER  

ifBERTDownBitErrRate 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.10
This string will represent a floating point number of the form [Er rRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers.
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

ifBERTUpBitErrRate 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.11
This object reflects the error rate of BERT in Upstream direction. This string will represent a floating point number of the form [ErrRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers.
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

ifBERTDownErroredSecs 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.12
This represents number of errored seconds downstream. Errored second is a second in which there is at least 1 block error.
OBJECT-TYPE    
  INTEGER  

ifBERTUpErroredSecs 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.13
This represents number of errored seconds upstream. Errored second is a second in which there is at least 1 block error.
OBJECT-TYPE    
  INTEGER  

ifBERTDownLineRate 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.14
This represents the downstream line rate in KBPS
OBJECT-TYPE    
  INTEGER  

ifBERTUpLineRate 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.15
This represents the Upstream line rate in KBPS
OBJECT-TYPE    
  INTEGER  

ifBERTDownMargin 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.16
This represents the Downstream margin in decibels (DB).
OBJECT-TYPE    
  INTEGER  

ifBERTUpMargin 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.17
This represents the upstream margin in decibels (DB).
OBJECT-TYPE    
  INTEGER  

diagApplTest 1.3.6.1.4.1.1795.2.24.2.16.1.2
OBJECT IDENTIFIER    

applMaxNumberOfTests 1.3.6.1.4.1.1795.2.24.2.16.1.2.1
This object identifies the maximum number of application based tests that can be simultaneously instantiated on the device.
OBJECT-TYPE    
  INTEGER  

applCurrentNumberOfTests 1.3.6.1.4.1.1795.2.24.2.16.1.2.2
This object identifies the current number of application based tests that are running on the device.
OBJECT-TYPE    
  INTEGER  

applStopAllTests 1.3.6.1.4.1.1795.2.24.2.16.1.2.3
The value of this object corresponds to stop all application based tests on the device. noOp -- no operation stop -- all the application tests will be stopped but current test results are still available stopAndClear -- all the application tests will be stoped and the results are cleared also
OBJECT-TYPE    
  INTEGER noOp(1), stop(2), stopAndClear(3)  

applNewTestId 1.3.6.1.4.1.1795.2.24.2.16.1.2.4
This value of this object corresponds to getting a magic number to start an application based test. The magic number is used as an index to create a row for the diagApplTestTable. If no new rows can be created, this object will have a value of 0.
OBJECT-TYPE    
  INTEGER  

applTestStatusTable 1.3.6.1.4.1.1795.2.24.2.16.1.2.5
This table controls all the application tests. It defines a test type, starts a test, and clears a test.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplTestStatusEntry

applTestStatusEntry 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1
An entry containing objects for invoking application based tests
OBJECT-TYPE    
  ApplTestStatusEntry  

applTestId 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.1
A unique ID to identify each application test.
OBJECT-TYPE    
  INTEGER  

applTestType 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.2
This object defines the application test type.
OBJECT-TYPE    
  AutonomousType  

applTestStatus 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.3
This object shows the current status of an application test. none - indicates waiting for test parameters. inProgress - indicates the test is in process. success - indicates the test is completed. failed - indicates the test is failed. abort - indicates the test was aborted
OBJECT-TYPE    
  INTEGER none(1), inProgress(2), success(3), failed(4), abort(5)  

applTestErrorCode 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.4
This object shows the reason for a test failure.
OBJECT-TYPE    
  INTEGER none(1), timeout(2), icmpError(3), systemError(4)  

applTestOwner 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.5
The network manager who has started the test
OBJECT-TYPE    
  DisplayString SIZE(1..40)  

applTestRowStatus 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.6
This object is used to create a new row or delete an existing row for an application test.
OBJECT-TYPE    
  RowStatus  

applPingTestTable 1.3.6.1.4.1.1795.2.24.2.16.1.2.6
This table contains objects which allow network manager to ping a destination.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplPingTestEntry

applPingTestEntry 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1
This table contains the input parameters for a ping test and the results of the ping test.
OBJECT-TYPE    
  ApplPingTestEntry  

applPingTestId 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.1
A unique ID to identify each application test.
OBJECT-TYPE    
  INTEGER  

applPingTestIpAddress 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.2
The IP address to be pinged.
OBJECT-TYPE    
  IpAddress  

applPingTestSourceIpAddr 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.3
The Source IP address where we are pinging from. This is an optional object for some devices. See operational specification for its use.
OBJECT-TYPE    
  IpAddress  

applPingTestPacketSize 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.4
This object corresponds to the size of the packet (in bytes) which will be sent during the Ping test. The default value for this object is 64 bytes
OBJECT-TYPE    
  INTEGER  

applPingTestTimeout 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.5
This object corresponds to a timeout value (in seconds) between Pings. The default value for this object is 5 seconds
OBJECT-TYPE    
  INTEGER  

applPingTestMaxPings 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.6
This object corresponds to the maximum number of times the device should Ping for the destination. The default value for this object is 10
OBJECT-TYPE    
  INTEGER  

applPingTestPktsSent 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.7
This object corresponds to the total number of packets sent.
OBJECT-TYPE    
  INTEGER  

applPingTestPktsRecv 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.8
This object corresponds to the total number of packets received without error
OBJECT-TYPE    
  INTEGER  

applPingTestMinTime 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.9
The minimum round trip time.
OBJECT-TYPE    
  INTEGER  

applPingTestMaxTime 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.10
The maximum round trip time.
OBJECT-TYPE    
  INTEGER  

applPingTestAvgTime 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.11
The average round trip time.
OBJECT-TYPE    
  INTEGER  

applPingTestDomain 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.12
This object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use.
OBJECT-TYPE    
  INTEGER noop(1), mgmt(2), service(3)  

applPingTestIfIndex 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.13
This object specifies the interface over which the ping test will take place.
OBJECT-TYPE    
  INTEGER  

applTracerouteConfigTable 1.3.6.1.4.1.1795.2.24.2.16.1.2.7
This table contains objects which allow network manager to enter the parameters of a traceroute test.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplTracerouteConfigEntry

applTracerouteConfigEntry 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1
This table contains the input parameters for a traceroute test.
OBJECT-TYPE    
  ApplTracerouteConfigEntry  

applTracerouteTestId 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.1
A unique ID to identify each application test.
OBJECT-TYPE    
  INTEGER  

applTracerouteIpAddress 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.2
The destination IP address of a traceroute test.
OBJECT-TYPE    
  IpAddress  

applTracerouteSourceIpAddr 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.3
The source IP address of where the traceroute test started. This is an optional object for some devices. See operational specification for its use.
OBJECT-TYPE    
  IpAddress  

applTraceroutePktsSize 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.4
This object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. The default value for this object is 38 bytes
OBJECT-TYPE    
  INTEGER  

applTracerouteTimeout 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.5
This object corresponds to a timeout value (in seconds) of a traceroute test. The default value for this object is 5 seconds
OBJECT-TYPE    
  INTEGER  

applTracerouteMaxHops 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.6
This object corresponds to the maximum number of hops to reach the destination. The default value for this object is device specific. See Operational Specifications
OBJECT-TYPE    
  INTEGER  

applTracerouteDomain 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.7
This object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use.
OBJECT-TYPE    
  INTEGER noop(1), mgmt(2), service(3)  

applTracerouteIfIndex 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.8
This object specifies the interface over which the trace-route test will take place.
OBJECT-TYPE    
  INTEGER  

applTracerouteResultTable 1.3.6.1.4.1.1795.2.24.2.16.1.2.8
This table contains results of traceroute test.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplTracerouteResultEntry

applTracerouteResultEntry 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1
An entry contains the objects for the traceroute test.
OBJECT-TYPE    
  ApplTracerouteResultEntry  

applTracerouteResultTestId 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.1
A unique ID to identify each application test.
OBJECT-TYPE    
  INTEGER  

applTracerouteHopCount 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.2
This object contains the number of hops to reach the gateway.
OBJECT-TYPE    
  INTEGER  

applTracerouteIpAddr 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.3
This object contains the IP address of the gateway.
OBJECT-TYPE    
  IpAddress  

applTraceroutePktSize 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.4
This object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. The default value for this object is 38 bytes
OBJECT-TYPE    
  INTEGER  

applTracerouteProbe1RTT 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.5
This object contains the round trip time (rtt) of the first probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
OBJECT-TYPE    
  INTEGER  

applTracerouteProbe2RTT 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.6
This object contains the round trip time (rtt) of the second probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
OBJECT-TYPE    
  INTEGER  

applTracerouteProbe3RTT 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.7
This object contains the round trip time (rtt) of the third probe sent to the gateway. If the probe has a timeout the rtt is set to -1.
OBJECT-TYPE    
  INTEGER  

diagTest 1.3.6.1.4.1.1795.2.24.2.16.1.3
OBJECT IDENTIFIER    

diagTestTrapEnable 1.3.6.1.4.1.1795.2.24.2.16.1.3.1
This object is used to disable or enable TestOver and TestStart trap for all tests. It is bit sum and possible bit positions are 1 TestStart trap 2 TestOver trap
OBJECT-TYPE    
  INTEGER  

diagTestMIBTraps 1.3.6.1.4.1.1795.2.24.2.16.2
OBJECT IDENTIFIER    

diagApplTestStart 1.3.6.1.4.1.1795.2.24.2.16.2.1
This trap signifies that an application test has been initiated.
TRAP-TYPE    
  ifIndex  
  applTestId  
  applTestType  

diagIfTestStart 1.3.6.1.4.1.1795.2.24.2.16.2.2
This trap signifies that a diagnostic test has been initiated.
TRAP-TYPE    
  ifTestId  

diagApplTestStop 1.3.6.1.4.1.1795.2.24.2.16.2.101
This trap signifies that an application test has completed. This trap compliments the diagApplTestStart trap.
TRAP-TYPE    
  ifIndex  
  applTestId  
  applTestType  
  applTestStatus  

diagIfTestOver 1.3.6.1.4.1.1795.2.24.2.16.2.102
This trap signifies that a diagnostic test has completed. This trap compliments the diagIfTestStart trap
TRAP-TYPE    
  ifTestId  

Defined Objects

IfLoopbackTestEntry  
SEQUENCE    
  INTEGER as loopbackTestInputNumCycles  
  INTEGER as loopbackTestResultsPktsSent  
  INTEGER as loopbackTestResultsPktsRcvdOK  
  INTEGER as loopbackTestResultsPktsRcvdErr  
  INTEGER as loopbackTestResultsPktsNotRcvd  
  DisplayString as loopbackTestResultsPktErrorRate  
  INTEGER as loopbackTestResultsErrSecs  
  INTEGER as loopbackTestResultsSvrErrSecs  
  INTEGER as loopbackTestResultsElpTime  

IfBERTObjectsEntry  
SEQUENCE    
  INTEGER as ifBERTTestDuration  
  INTEGER as ifBERTElapsedTime  
  INTEGER as ifBERTDownSyncUP  
  INTEGER as ifBERTUpSyncUP  
  INTEGER as ifBERTSegmentsSent  
  INTEGER as ifBERTDownMBitsRcvd  
  INTEGER as ifBERTUpMBitsRcvd  
  INTEGER as ifBERTDownBitErrDetected  
  INTEGER as ifBERTUpBitErrDetected  
  DisplayString as ifBERTDownBitErrRate  
  DisplayString as ifBERTUpBitErrRate  
  INTEGER as ifBERTDownErroredSecs  
  INTEGER as ifBERTUpErroredSecs  
  INTEGER as ifBERTDownLineRate  
  INTEGER as ifBERTUpLineRate  
  INTEGER as ifBERTDownMargin  
  INTEGER as ifBERTUpMargin  

ApplTestStatusEntry  
SEQUENCE    
  INTEGER as applTestId  
  AutonomousType as applTestType  
  INTEGER as applTestStatus  
  INTEGER as applTestErrorCode  
  DisplayString as applTestOwner  
  RowStatus as applTestRowStatus  

ApplPingTestEntry  
SEQUENCE    
  INTEGER as applPingTestId  
  IpAddress as applPingTestIpAddress  
  IpAddress as applPingTestSourceIpAddr  
  INTEGER as applPingTestPacketSize  
  INTEGER as applPingTestTimeout  
  INTEGER as applPingTestMaxPings  
  INTEGER as applPingTestPktsSent  
  INTEGER as applPingTestPktsRecv  
  INTEGER as applPingTestMinTime  
  INTEGER as applPingTestMaxTime  
  INTEGER as applPingTestAvgTime  
  INTEGER as applPingTestDomain  
  INTEGER as applPingTestIfIndex  

ApplTracerouteConfigEntry  
SEQUENCE    
  INTEGER as applTracerouteTestId  
  IpAddress as applTracerouteIpAddress  
  IpAddress as applTracerouteSourceIpAddr  
  INTEGER as applTraceroutePktsSize  
  INTEGER as applTracerouteTimeout  
  INTEGER as applTracerouteMaxHops  
  INTEGER as applTracerouteDomain  
  INTEGER as applTracerouteIfIndex  

ApplTracerouteResultEntry  
SEQUENCE    
  INTEGER as applTracerouteResultTestId  
  INTEGER as applTracerouteHopCount  
  IpAddress as applTracerouteIpAddr  
  INTEGER as applTraceroutePktSize  
  INTEGER as applTracerouteProbe1RTT  
  INTEGER as applTracerouteProbe2RTT  
  INTEGER as applTracerouteProbe3RTT