PHIHONG-PoE-MIB

File: PHIHONG-PoE-MIB.mib (17913 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Gauge32
NOTIFICATION-TYPE DisplayString TruthValue
IpAddress enterprises

Defined Objects

phihong 1.3.6.1.4.1.24852
OBJECT IDENTIFIER    

poeProduct 1.3.6.1.4.1.24852.2
OBJECT IDENTIFIER    

poeProductsPart 1.3.6.1.4.1.24852.2.1
the POE controller Part.
OBJECT-TYPE    
  DisplayString  

poeSystem 1.3.6.1.4.1.24852.2.2
OBJECT IDENTIFIER    

poeSystemActionHubReset 1.3.6.1.4.1.24852.2.2.1
Reset the POE controller.
OBJECT-TYPE    
  INTEGER ready(0), reset(1)  

poeSystemActionHubRestoreFactoryDefault 1.3.6.1.4.1.24852.2.2.2
Restore Factory Default to flash. resetpassword means when users forget the password,they can use this entry, and all of the snmp module parameters will be set to default values.
OBJECT-TYPE    
  INTEGER ready(0), restore(1)  

poeSystemActionHubSaveConfiguration 1.3.6.1.4.1.24852.2.2.3
Save the POE parameters to flash
OBJECT-TYPE    
  INTEGER ready(0), save(1)  

poeSystemAllPortPowerEnable 1.3.6.1.4.1.24852.2.2.4
Enables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value disable(1) disables power for all port.
OBJECT-TYPE    
  INTEGER ready(0), disable(1), enable(2)  

poeSystemHWVersion 1.3.6.1.4.1.24852.2.2.6
System hardware version for the Main board
OBJECT-TYPE    
  DisplayString  

poeSystemNumberOfChannel 1.3.6.1.4.1.24852.2.2.7
Number of ports in the system
OBJECT-TYPE    
  INTEGER  

poeSystemProductPartNumber 1.3.6.1.4.1.24852.2.2.8
System Part Number for PowerHub
OBJECT-TYPE    
  DisplayString  

poeSystemFirmwareVersion 1.3.6.1.4.1.24852.2.2.10
System firmware version for the POE
OBJECT-TYPE    
  DisplayString  

poeSystemDescription 1.3.6.1.4.1.24852.2.2.11
System Description 10 characters
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

poeSystemConsumptionPower 1.3.6.1.4.1.24852.2.2.12
Measured usage power expressed in Watts.
OBJECT-TYPE    
  INTEGER  

poeSystemControlACPower 1.3.6.1.4.1.24852.2.2.13
describes the maximum available power in Watts to be supplied by the AC backup source to this device.
OBJECT-TYPE    
  INTEGER  

poeSystemControlDCPower 1.3.6.1.4.1.24852.2.2.14
describes the maximum available power in Watts to be supplied by the DC backup source to this device.
OBJECT-TYPE    
  INTEGER  

poeSystemControlBothPower 1.3.6.1.4.1.24852.2.2.15
describes the maximum available power in Watts to be supplied by Both AC and DC backup source to this device.
OBJECT-TYPE    
  INTEGER  

poeSystemParameters 1.3.6.1.4.1.24852.2.2.16
1st char:Knokoff enable,2nd char:AC Disconnect enable,3th char:Disable Power Management
OBJECT-TYPE    
  DisplayString SIZE(3)  

poeSystemSnmpVersion 1.3.6.1.4.1.24852.2.2.17
The software version for the SNMP device
OBJECT-TYPE    
  DisplayString  

poeSystemPerPortPowerEnable 1.3.6.1.4.1.24852.2.2.18
Enables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value disable(1) disables power for all port.
OBJECT-TYPE    
  DisplayString SIZE(48)  

poeSystemStatus 1.3.6.1.4.1.24852.2.2.19
The status of the POE.
OBJECT-TYPE    
  INTEGER normal(0), overheat(1)  

poePortTable 1.3.6.1.4.1.24852.2.3
OBJECT-TYPE    
  SEQUENCE OF  
    PoePortEntry

poePortEntry 1.3.6.1.4.1.24852.2.3.1
port entry containing data regarding a particular port
OBJECT-TYPE    
  PoePortEntry  

poePortIndex 1.3.6.1.4.1.24852.2.3.1.1
A unique value for each port.
OBJECT-TYPE    
  INTEGER 1..2147483647  

poePortPowerEnable 1.3.6.1.4.1.24852.2.3.1.2
Enables power supply on this port. Setting this object at a value enable(2) enables power and detection mechanism for this port. Setting this object at a value disable(1) disables power for this port.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

poePortControlMaxPower 1.3.6.1.4.1.24852.2.3.1.3
This command specifies the max power in [mWatts] to that port. IF you set this value it will take out this port from the auto mode. The value MUST be more then 0
OBJECT-TYPE    
  INTEGER  

poePortDescription 1.3.6.1.4.1.24852.2.3.1.6
Port Description 10 characters
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

poePortDetectionStatus 1.3.6.1.4.1.24852.2.3.1.7
Port Detection, show the detection status of each port
OBJECT-TYPE    
  INTEGER off(0), discR(1), discC(2), class(3), rampUp(4), ramPOEown(5), sampleI(8), sampleV(9)  

poePortPowerClassifications 1.3.6.1.4.1.24852.2.3.1.8
Port Power Classifications, show the classification of each port
OBJECT-TYPE    
  INTEGER class0(1), class1(2), class2(3), class3(4), class4(5)  

poePortPowerDetectionControl 1.3.6.1.4.1.24852.2.3.1.9
Port Power Detection Control, enable or disable the Power Limit for Management
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

poePortPowerPriority 1.3.6.1.4.1.24852.2.3.1.10
Port Power Priority, show the priority of each port
OBJECT-TYPE    
  INTEGER critical(1), high(2), low(3)  

poePortPower 1.3.6.1.4.1.24852.2.3.1.11
Port Actual Power (in mWattes).
OBJECT-TYPE    
  INTEGER  

poePortVoltage 1.3.6.1.4.1.24852.2.3.1.12
Port Voltage (in dVoltage).
OBJECT-TYPE    
  DisplayString  

poePortCurrent 1.3.6.1.4.1.24852.2.3.1.13
Port Current (in mAmps).
OBJECT-TYPE    
  INTEGER  

poePortResistance 1.3.6.1.4.1.24852.2.3.1.14
Port Resistance (in ohms).
OBJECT-TYPE    
  INTEGER  

poePortFlags 1.3.6.1.4.1.24852.2.3.1.15
1st char:classification(0-3),2nd char:Port bypass detection enable,3th char:Port bypass classifiation enable,4th cahr:Port bypass powerup enable,5th char:Port bypass sampling enable.
OBJECT-TYPE    
  DisplayString SIZE(5)  

poePortBypassFlags 1.3.6.1.4.1.24852.2.3.1.16
1st char:Port bypass detection enable,2nd char:Port bypass classifiation enable,3th cahr:Port bypass powerup enable,4th char:Port bypass sampling enable.
OBJECT-TYPE    
  DisplayString SIZE(4)  

poePortUseClassificationforPowerLimit 1.3.6.1.4.1.24852.2.3.1.17
Use Port classification for power limit , enable or disable the Port classification for power limit.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

poePortLegacyDetection 1.3.6.1.4.1.24852.2.3.1.18
Use Port legacy detection , enable or disable the Port legacy detection.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

poeTrapsControlTable 1.3.6.1.4.1.24852.2.4
A table of objects that display and control the Traps on a PSM device.
OBJECT-TYPE    
  SEQUENCE OF  
    PoeTrapsControlEntry

poeTrapsControlEntry 1.3.6.1.4.1.24852.2.4.1
A set of objects that control the Trap events.
OBJECT-TYPE    
  PoeTrapsControlEntry  

poeTrapsControlGroupIndex 1.3.6.1.4.1.24852.2.4.1.1
This variable uniquely identifies the group.
OBJECT-TYPE    
  INTEGER 0..65535  

poeTrapsControlEnable 1.3.6.1.4.1.24852.2.4.1.2
Enable Traps from Agent
OBJECT-TYPE    
  INTEGER trapsDisabled(1), trapsEnabled(2)  

poeTraps 1.3.6.1.4.1.24852.2.5
OBJECT IDENTIFIER    

poePortHWFailTrap 1.3.6.1.4.1.24852.2.5.1
This trap indicate UV0v failure /UV0v Spike failure /Device A2d failure.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortVoltage  

poePortPeakOverCurrentTrap 1.3.6.1.4.1.24852.2.5.2
This trap indicate peak over current failure.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortCurrent  

poePortOverloadTrap 1.3.6.1.4.1.24852.2.5.3
This trap indicate overload failure. If you put at least 400mA on the output, you will see if your traps work
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortDetectionStatus  

poePortDiscoveryFailTrap 1.3.6.1.4.1.24852.2.5.4
This trap indicate Discovery failure/ Discovery VA2 failure/Discovery RA2 failure/Sample Discovery A2d Failure.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortVoltage  

poePortClassificationFailTrap 1.3.6.1.4.1.24852.2.5.5
This trap indicate Class Violation failure/ Classification A2d failure.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortVoltage  

poePortDisconnectTrap 1.3.6.1.4.1.24852.2.5.6
This trap indicate port is disconnected.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortDetectionStatus  

poePortVoltageFailTrap 1.3.6.1.4.1.24852.2.5.7
This trap indicate if PSM Port is no voltage failure.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  
  poePortVoltage  

poeSystemOverheatTrap 1.3.6.1.4.1.24852.2.5.8
This trap indicate if PSM is overheat.
NOTIFICATION-TYPE    
  poeTrapsControlGroupIndex  

Defined Objects

PoePortEntry  
SEQUENCE    
  INTEGER as poePortIndex  
  INTEGER as poePortPowerEnable  
  INTEGER as poePortControlMaxPower  
  DisplayString as poePortDescription  
  INTEGER as poePortDetectionStatus  
  INTEGER as poePortPowerClassifications  
  INTEGER as poePortPowerDetectionControl  
  INTEGER as poePortPowerPriority  
  INTEGER as poePortPower  
  DisplayString as poePortVoltage  
  INTEGER as poePortCurrent  
  INTEGER as poePortResistance  
  DisplayString as poePortFlags  
  DisplayString as poePortBypassFlags  
  INTEGER as poePortUseClassificationforPowerLimit  
  INTEGER as poePortLegacyDetection  

PoeTrapsControlEntry  
SEQUENCE    
  INTEGER as poeTrapsControlGroupIndex  
  INTEGER as poeTrapsControlEnable