PM8ECCMIB

File: PM8ECCMIB.mib (49409 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215

Imported symbols

enterprises OBJECT-TYPE TRAP-TYPE

Defined Objects

schneiderElectric 1.3.6.1.4.1.3833
OBJECT IDENTIFIER    

transparentFactoryEthernet 1.3.6.1.4.1.3833.1
OBJECT IDENTIFIER    

equipmentProfile 1.3.6.1.4.1.3833.1.7
OBJECT IDENTIFIER    

tfProducts 1.3.6.1.4.1.3833.1.7.255
OBJECT IDENTIFIER    

ecc 1.3.6.1.4.1.3833.1.7.255.15
OBJECT IDENTIFIER    

pm8ecc 1.3.6.1.4.1.3833.1.7.255.15.1
OBJECT IDENTIFIER    

metering 1.3.6.1.4.1.3833.1.7.255.15.1.1
OBJECT IDENTIFIER    

pm8OnBoardAlarmP1 1.3.6.1.4.1.3833.1.7.255.15.1.1
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 1
TRAP-TYPE    
  alarmDateAndTime  
  alarmLabel  
  alarmState  
  alarmValue  
  alarmPriority  

systemWiringTypeTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.1
The wiring system type of the host meter.
OBJECT-TYPE    
  SEQUENCE OF  
    SystemWiringTypeEntry

systemWiringTypeEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1
Host Meter System Wiring Type
OBJECT-TYPE    
  SystemWiringTypeEntry  

swtIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.1
System Wiring Type Table Index
OBJECT-TYPE    
  INTEGER 1..255  

swtWiringType 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.2
Single Phase Line to Neutral 2 Wire 1CT 1PT is '10' Single Phase Line to Line 2 Wire 1CT 1PT is '11' Single Phase 3-Wire 3 wire 2CT 2PT is '12' Three Phase 3 Wire 2CT 2PT is '30' Three Phase 3 Wire 3CT 2PT is '31' Three Phase 3 Wire 1CT 2PT is '32' Three Phase 4 Wire 3CT 3PT is '40' Three Phase 4 Wire 3CT 2PT is '42' Three Phase 4 Wire 1CT 3PT is '44'
OBJECT-TYPE    
  INTEGER 10 | 11 | 12 | 30 | 31 | 32 | 40 | 42 | 44  

loadCurrentTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.2
Host Meter Load Current Table
OBJECT-TYPE    
  SEQUENCE OF  
    LoadCurrentEntry

loadCurrentEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1
Host Meter Load Current Table
OBJECT-TYPE    
  LoadCurrentEntry  

lcIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.1
Load Current Table Index
OBJECT-TYPE    
  INTEGER 1..255  

lcIa 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.2
Host Meter Load Current Phase A Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

lcIb 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.3
Host Meter Load Current Phase B Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

lcIc 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.4
Host Meter Load Current Phase C Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

lcIAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.5
Host Meter Load Current 3 Phase Average Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

powerTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.3
Host Meter Power Table
OBJECT-TYPE    
  SEQUENCE OF  
    PowerEntry

powerEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1
Host Meter Power Table
OBJECT-TYPE    
  PowerEntry  

pIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.1
Power Table Index
OBJECT-TYPE    
  INTEGER 1..255  

pReal 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.2
Host Meter Real Power Units = kW
OBJECT-TYPE    
  OCTET STRING  

pReactive 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.3
Host Meter Reactive Power Units = kVAR
OBJECT-TYPE    
  OCTET STRING  

pApparent 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.4
Host Meter Apparent Power Units = kVA
OBJECT-TYPE    
  OCTET STRING  

powerFactorTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.4
Host Meter Power Factor Table
OBJECT-TYPE    
  SEQUENCE OF  
    PowerFactorEntry

powerFactorEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1
Host Meter Power Factor Table
OBJECT-TYPE    
  PowerFactorEntry  

pfIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.1
Power Factor Table Index
OBJECT-TYPE    
  INTEGER 1..255  

pfPowerFactorTotal 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.2
Host Meter 3 Phase Total Power Factor
OBJECT-TYPE    
  OCTET STRING  

pfPowerFactorDescription 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.3
Describes the current power factor Lead/Lag for IEEE mode Cap/Ind for IEC mode
OBJECT-TYPE    
  OCTET STRING  

voltageTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.5
Host Meter Voltage Table
OBJECT-TYPE    
  SEQUENCE OF  
    VoltageEntry

voltageEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1
Host Meter Voltage Table
OBJECT-TYPE    
  VoltageEntry  

vIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.1
Voltage Table Index
OBJECT-TYPE    
  INTEGER 1..255  

vVab 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.2
Host Meter Voltage Line A to Line B Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVbc 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.3
Host Meter Voltage Line B to Line C Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVca 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.4
Host Meter Voltage Line C to Line A Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVllAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.5
Host Meter Voltage Line to Line Average Voltage Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVan 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.6
Host Meter Voltage Line A to Neutral Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVbn 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.7
Host Meter Voltage Line B to Neutral Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVcn 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.8
Host Meter Voltage Line C to Neutral Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

vVlnAvg 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.9
Host Meter Voltage Line to Neutral 3 Phase Average Units = V (Volts)
OBJECT-TYPE    
  OCTET STRING  

frequencyTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.6
Host Meter Frequency Table
OBJECT-TYPE    
  SEQUENCE OF  
    FrequencyEntry

frequencyEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1
Host Meter Frequency Table
OBJECT-TYPE    
  FrequencyEntry  

fIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.1
Frequency Table Index
OBJECT-TYPE    
  INTEGER 1..255  

fFrequency 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.2
Host Meter Frequency Units = Hz
OBJECT-TYPE    
  OCTET STRING  

currentDemandTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.7
Host Meter Current Demand Table
OBJECT-TYPE    
  SEQUENCE OF  
    CurrentDemandEntry

currentDemandEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1
Host Meter Current Demand Table
OBJECT-TYPE    
  CurrentDemandEntry  

cdIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.1
Demand Current Table Index
OBJECT-TYPE    
  INTEGER 1..255  

cdPhase 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.2
Host Meter Current Demand Phase Name
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

cdPresentCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.3
Host Meter Present Demand Current Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

cdPeakCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.4
Host Meter Peak Current Demand Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

cdLastCurrentDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.5
Host Meter Current Demand Last Interval Units = A (Amps)
OBJECT-TYPE    
  OCTET STRING  

cdPeakDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.6
Host Meter Peak Current Demand Date and Time
OBJECT-TYPE    
  OCTET STRING  

cdResetDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.7
Host Meter Date and Time of Demand Current Reset
OBJECT-TYPE    
  OCTET STRING  

cdPhaseEnum 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.8
Host Meter Current Demand Phase
OBJECT-TYPE    
  INTEGER currentPhaseA(1), currentPhaseB(2), currentPhaseC(3)  

powerDemandTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.8
Host Meter Power Demand
OBJECT-TYPE    
  SEQUENCE OF  
    PowerDemandEntry

powerDemandEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1
Host Meter Power Demand Table
OBJECT-TYPE    
  PowerDemandEntry  

pdIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.1
Power Demand Table Index
OBJECT-TYPE    
  INTEGER 1..255  

pdComponent 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.2
Host Meter Power Demand Component Units: Real = kW Reacitve = kVAR Apparent = kVA
OBJECT-TYPE    
  OCTET STRING SIZE(4..8)  

pdPresentPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.3
Host Meter Present Demand Power
OBJECT-TYPE    
  OCTET STRING  

pdPeakPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.4
Host Meter Peak Power Demand
OBJECT-TYPE    
  OCTET STRING  

pdLastPowerDemand 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.5
Host Meter Power Demand Last Interval
OBJECT-TYPE    
  OCTET STRING  

pdPeakDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.6
Host Meter Peak Power Demand Date and Time
OBJECT-TYPE    
  OCTET STRING  

pdResetDateTime 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.7
Host Meter Date and Time of Power Demand Reset
OBJECT-TYPE    
  OCTET STRING  

pdComponentEnum 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.8
Host Meter Power Demand Component
OBJECT-TYPE    
  INTEGER realPower(1), reactivePower(2), apparentPower(3)  

energyTable 1.3.6.1.4.1.3833.1.7.255.15.1.1.9
Host Meter Energy Table
OBJECT-TYPE    
  SEQUENCE OF  
    EnergyEntry

energyEntry 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1
Host Meter Energy Table
OBJECT-TYPE    
  EnergyEntry  

eIndex 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.1
Energy Table Index
OBJECT-TYPE    
  INTEGER 1..255  

eRealEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.2
Host Meter Real Energy Units = kWh
OBJECT-TYPE    
  OCTET STRING  

eDateTimeRealEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.3
Host Meter Date and Time Real Energy Accumulation was reset
OBJECT-TYPE    
  OCTET STRING  

eReactiveEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.4
Host Meter Reactive Energy Units = kVARh
OBJECT-TYPE    
  OCTET STRING  

eDateTimeReactiveEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.5
Host Meter Date and Time Reative Energy Accumulation was reset
OBJECT-TYPE    
  OCTET STRING  

eApparentEnergy 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.6
Host Meter Apparent Energy Units = kVAh
OBJECT-TYPE    
  OCTET STRING  

eDateTimeApparentEnergyReset 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.7
Host Meter Date and Time Reactive Energy Accumulation was reset
OBJECT-TYPE    
  OCTET STRING  

alarms 1.3.6.1.4.1.3833.1.7.255.15.1.2
OBJECT IDENTIFIER    

pm8OnBoardAlarmP2 1.3.6.1.4.1.3833.1.7.255.15.1.2
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 2
TRAP-TYPE    
  alarmDateAndTime  
  alarmLabel  
  alarmState  
  alarmValue  
  alarmPriority  

alarmConfigurationTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.1
Displays the current configuration of the Host Meter On-board alarms
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmConfigurationEntry

alarmConfigurationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1
Contains configuration information for the Host Meter On-board Alarms
OBJECT-TYPE    
  AlarmConfigurationEntry  

acIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.1
Alarm Configuration Table Index
OBJECT-TYPE    
  INTEGER 1..255  

acPosition 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.2
Indicates the position of the alarm. 1 - 74
OBJECT-TYPE    
  INTEGER 1..74  

acAlarmLabel 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.3
The name of the alarm (user configurable)
OBJECT-TYPE    
  AlarmLabel  

acEnabled 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.4
Indicates whether the alarm is enabled or not. 0 = Disabled 255 = Enabled
OBJECT-TYPE    
  INTEGER 0 | 255  

acStatus 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.5
Indicates whether the alarm is active. 0 = Inactive 1 = Active
OBJECT-TYPE    
  INTEGER 0..1  

acCounter 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.6
Indicates the number of times the alarm has been activated. Note: This counter resets at 32767
OBJECT-TYPE    
  INTEGER 0..32767  

acPriority 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.7
The priority of the alarm. 0 = No Priority 1 = Low Priority 2 = Medium Priority 3 = High Priority
OBJECT-TYPE    
  INTEGER 0..3  

acType 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.8
Indicates the type of the alarm.
OBJECT-TYPE    
  AlarmType  

acAlarmList1 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.9
Used for combinatorial type alarms - The position of the first alarm that is used to evaluate the alarm state.
OBJECT-TYPE    
  INTEGER  

acAlarmList2 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.10
Used for combinatorial type alarms - The position of the second alarm that is used to evaluate the alarm state.
OBJECT-TYPE    
  INTEGER  

acAlarmList3 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.11
Used for combinatorial type alarms - The position of the third alarm that is used to evaluate the alarm state.
OBJECT-TYPE    
  INTEGER  

acAlarmList4 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.12
Used for combinatorial type alarms - The position of the fourth alarm that is used to evaluate the alarm state.
OBJECT-TYPE    
  INTEGER  

alarmSummaryBitmapsTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.2
Indicates the state of the Host Meter On-Board Alarms
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmSummaryBitmapsEntry

alarmSummaryBitmapsEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1
Indicates the status of the Host Meter On-Board Alarms
OBJECT-TYPE    
  AlarmSummaryBitmapsEntry  

alSumIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.1
Alarm Summary Bitmap Table Index
OBJECT-TYPE    
  INTEGER 1..255  

alSumAlarms1to16 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.2
Indicates the status of Alarms 1 - 16 (16-bits, bit-0 = Alarm 1)
OBJECT-TYPE    
  OCTET STRING SIZE(16)  

alSumAlarms17to32 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.3
Indicates the status of Alarms 17 - 32 (16-bits, bit-0 = Alarm 17)
OBJECT-TYPE    
  OCTET STRING SIZE(16)  

alSumAlarms33to48 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.4
Indicates the status of Alarms 33 - 48 (16-bits, bit-0 = Alarm 33)
OBJECT-TYPE    
  OCTET STRING SIZE(16)  

alSumAlarms49to64 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.5
Indicates the status of Alarms 49 - 64 (16-bits, bit-0 = Alarm 49)
OBJECT-TYPE    
  OCTET STRING SIZE(16)  

alSumAlarms65to74 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.6
Indicates the status of Alarms 65 - 74 (16-bits, bit-0 = Alarm 65, bit-9 = Alarm 74)
OBJECT-TYPE    
  OCTET STRING SIZE(16)  

alarmCountersTable 1.3.6.1.4.1.3833.1.7.255.15.1.2.3
Host Meter On-Board Alarm Counters
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmCountersEntry

alarmCountersEntry 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1
Host Meter On-Board Alarm Counters
OBJECT-TYPE    
  AlarmCountersEntry  

alCntIndex 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.1
Alarm Counters Table Index
OBJECT-TYPE    
  INTEGER 1..255  

alCntAlarmPosition 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.2
The Host Meter Alarm Position
OBJECT-TYPE    
  INTEGER 1..74  

alCntCount 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.3
The number of times the Host Meter On-Board alarm has transitioned from an inactive state to an active state
OBJECT-TYPE    
  INTEGER 0..65535  

io 1.3.6.1.4.1.3833.1.7.255.15.1.3
OBJECT IDENTIFIER    

pm8OnBoardAlarmP3 1.3.6.1.4.1.3833.1.7.255.15.1.3
Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 3
TRAP-TYPE    
  alarmDateAndTime  
  alarmLabel  
  alarmState  
  alarmValue  
  alarmPriority  

ioOptionIDTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.1
I/O Option Module Installed on the Host Meter
OBJECT-TYPE    
  SEQUENCE OF  
    IoOptionIDEntry

ioOptionIDEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1
I/O Option Card Installed On-board the Host Meter
OBJECT-TYPE    
  IoOptionIDEntry  

ioIDIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.1
I/O Installed Option ID Table Index
OBJECT-TYPE    
  INTEGER 1..255  

ioIDInstalledOptionSlot1 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.2
0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222
OBJECT-TYPE    
  INTEGER unused(1), io-22(2), io-26(3), io-2222(4)  

ioIDInstalledOptionSlot2 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.3
0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222
OBJECT-TYPE    
  INTEGER unused(1), io-22(2), io-26(3), io-2222(4)  

ioConfigurationTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.2
Displays the current I/O configuration for each I/O point
OBJECT-TYPE    
  SEQUENCE OF  
    IoConfigurationEntry

ioConfigurationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1
Contains configuration information for the Host Meter On-board I/O
OBJECT-TYPE    
  IoConfigurationEntry  

iocIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.1
I/O Configuration Table Index
OBJECT-TYPE    
  INTEGER 1..255  

iocPointNumber 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.2
The point number for this I/O Point
OBJECT-TYPE    
  INTEGER 1..18  

iocLabel 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.3
The name of the I/O Point (user configurable)
OBJECT-TYPE    
  IOPointLabel  

iocStateOrValue 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.4
Displays the current value for the I/O Point Digial I/O: 1 = Active or 0 = Inactive Analog I/O: Scaled input/output value
OBJECT-TYPE    
  OCTET STRING  

iocPointType 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.5
The type of I/O at this point
OBJECT-TYPE    
  IOPointType  

iocMode 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.6
For Digital Inputs and Outputs this object is always 0 indicating “Discrete”. For Analog Inputs and Outputs this object indicates the range of analog I/O values (used without units) 0 = 0 – 1 1 = 0 – 5 2 = 0 – 10 3 = 0 – 20 4 = 1 – 5 5 = 4 – 20 6 = -5 – 5 7 = -10 – 10 8 = -100 – 100 9 = User defined (values default to 0)
OBJECT-TYPE    
  INTEGER 0..9  

iocType 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.7
For Digital Inputs this object indicates input type 1 = Unused 2 = AC/DC For Digital Outputs this object indicates output type 1 = solid state relay 2 = electromechanical relay For Analog Inputs and Outputs this object indicates the digital resolution of the I/O hardware. 0 = 8-Bit, unipolar 1 = 10-Bit, unipolar 2 = 12-Bit, unipolar 3 = 14-Bit, unipolar 4 = 16-Bit, unipolar 5 = 16-Bit, bipolar with sign 6 = reserved 7 = reserved 8 = Resolution for IO2222 Voltage range 0 - 4000 9 = Resolution for IO2222 Current range 800 - 4000
OBJECT-TYPE    
  INTEGER  

iocCount 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.8
Number of times digital I/O point has transitioned from OFF to ON
OBJECT-TYPE    
  OCTET STRING SIZE(8)  

ioStatusBitmapsTable 1.3.6.1.4.1.3833.1.7.255.15.1.3.3
Host Meter I/O Status Bitmaps
OBJECT-TYPE    
  SEQUENCE OF  
    IoStatusBitmapsEntry

ioStatusBitmapsEntry 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1
Host Meter On-Board I/O Status Bitmaps
OBJECT-TYPE    
  IoStatusBitmapsEntry  

ioStatIndex 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.1
I/O Summary Bitmaps Table Index
OBJECT-TYPE    
  INTEGER 1..255  

ioStatSummaryBitmap 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.2
Indicates the Status of the Host Meter I/O Points Bit-0 = I/O Point 1 Bit-1 = I/O Point 2 ... Bit-17 = I/O Point 18
OBJECT-TYPE    
  OCTET STRING SIZE(18)  

meterSystem 1.3.6.1.4.1.3833.1.7.255.15.1.4
OBJECT IDENTIFIER    

meterIdentificationTable 1.3.6.1.4.1.3833.1.7.255.15.1.4.1
Host Meter Identification
OBJECT-TYPE    
  SEQUENCE OF  
    MeterIdentificationEntry

meterIdentificationEntry 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1
Host Meter Identification
OBJECT-TYPE    
  MeterIdentificationEntry  

midIndex 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.1
Meter Identification Table Index
OBJECT-TYPE    
  INTEGER 1..255  

midSerialNumber 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.2
Host meter 32 bit Serial Number
OBJECT-TYPE    
  INTEGER  

midFirmwareVersion 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.3
Host Meter Firmware Version
OBJECT-TYPE    
  OCTET STRING  

midModelNumber 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.4
Host Meter Model Number
OBJECT-TYPE    
  OCTET STRING  

midDeviceName 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.5
Host Meter Label plus Nameplate
OBJECT-TYPE    
  OCTET STRING  

trapVariables 1.3.6.1.4.1.3833.1.7.255.15.1.5
OBJECT IDENTIFIER    

alarmDateAndTime 1.3.6.1.4.1.3833.1.7.255.15.1.5.1
The Date and Time of the alarm state change.
OBJECT-TYPE    
  OCTET STRING  

alarmLabel 1.3.6.1.4.1.3833.1.7.255.15.1.5.2
The Descriptive Label given to the alarm
OBJECT-TYPE    
  OCTET STRING  

alarmState 1.3.6.1.4.1.3833.1.7.255.15.1.5.3
The state of the Alarm - pickup, dropout, unary, diagnostic
OBJECT-TYPE    
  OCTET STRING  

alarmValue 1.3.6.1.4.1.3833.1.7.255.15.1.5.4
The value of the alarm when it changed state.
OBJECT-TYPE    
  INTEGER  

alarmPriority 1.3.6.1.4.1.3833.1.7.255.15.1.5.5
The priority defined for the alarm.
OBJECT-TYPE    
  INTEGER highPriority(1), mediumPriority(2), lowPriority(3)  

mibVersion 1.3.6.1.4.1.3833.1.7.255.15.1.6
This is the current version of the MIB
OBJECT-TYPE    
  OCTET STRING  

Defined Objects

AlarmType  
INTEGER overValue(10), overPower(11), overReversePower(12), underValue(20), underPower(21), phaseRotationReversal(51), phaseLossVoltage(52), phaseLossCurrent(53), powerFactorLeading(54), powerFactorLagging(55), digitalInputOFFtoON(60), digitalInputONtoOFF(61), unaryEvent(70), voltageOrCurrentSwell(80), voltageOrCurrentSag(90), combinatorialAND(100), combinatorialNAND(101), combinatorialOR(102), combinatorialNOR(103), combinatorialXOR(104), combinatorialNOT(105), diagnostic(1280)    

IOPointType  
INTEGER digitalInput(1), digitalOutput(2), analogInput(3), analogOutput(4)    

IOPointLabel  
OCTET STRING SIZE(0..16)    

AlarmLabel  
OCTET STRING SIZE(0..16)    

SystemWiringTypeEntry  
SEQUENCE    
  INTEGER as swtIndex  
  INTEGER as swtWiringType  

LoadCurrentEntry  
SEQUENCE    
  INTEGER as lcIndex  
  OCTET STRING as lcIa  
  OCTET STRING as lcIb  
  OCTET STRING as lcIc  
  OCTET STRING as lcIAvg  

PowerEntry  
SEQUENCE    
  INTEGER as pIndex  
  OCTET STRING as pReal  
  OCTET STRING as pReactive  
  OCTET STRING as pApparent  

PowerFactorEntry  
SEQUENCE    
  INTEGER as pfIndex  
  OCTET STRING as pfPowerFactorTotal  
  OCTET STRING as pfPowerFactorDescription  

VoltageEntry  
SEQUENCE    
  INTEGER as vIndex  
  OCTET STRING as vVab  
  OCTET STRING as vVbc  
  OCTET STRING as vVca  
  OCTET STRING as vVllAvg  
  OCTET STRING as vVan  
  OCTET STRING as vVbn  
  OCTET STRING as vVcn  
  OCTET STRING as vVlnAvg  

FrequencyEntry  
SEQUENCE    
  INTEGER as fIndex  
  OCTET STRING as fFrequency  

CurrentDemandEntry  
SEQUENCE    
  INTEGER as cdIndex  
  OCTET STRING as cdPhase  
  OCTET STRING as cdPresentCurrentDemand  
  OCTET STRING as cdPeakCurrentDemand  
  OCTET STRING as cdLastCurrentDemand  
  OCTET STRING as cdPeakDateTime  
  OCTET STRING as cdResetDateTime  
  INTEGER as cdPhaseEnum  

PowerDemandEntry  
SEQUENCE    
  INTEGER as pdIndex  
  OCTET STRING as pdComponent  
  OCTET STRING as pdPresentPowerDemand  
  OCTET STRING as pdPeakPowerDemand  
  OCTET STRING as pdLastPowerDemand  
  OCTET STRING as pdPeakDateTime  
  OCTET STRING as pdResetDateTime  
  INTEGER as pdComponentEnum  

EnergyEntry  
SEQUENCE    
  INTEGER as eIndex  
  OCTET STRING as eRealEnergy  
  OCTET STRING as eDateTimeRealEnergyReset  
  OCTET STRING as eReactiveEnergy  
  OCTET STRING as eDateTimeReactiveEnergyReset  
  OCTET STRING as eApparentEnergy  
  OCTET STRING as eDateTimeApparentEnergyReset  

AlarmConfigurationEntry  
SEQUENCE    
  INTEGER as acIndex  
  INTEGER as acPosition  
  AlarmLabel as acAlarmLabel  
  INTEGER as acEnabled  
  INTEGER as acStatus  
  INTEGER as acCounter  
  INTEGER as acPriority  
  AlarmType as acType  
  INTEGER as acAlarmList1  
  INTEGER as acAlarmList2  
  INTEGER as acAlarmList3  
  INTEGER as acAlarmList4  

AlarmSummaryBitmapsEntry  
SEQUENCE    
  INTEGER as alSumIndex  
  OCTET STRING as alSumAlarms1to16  
  OCTET STRING as alSumAlarms17to32  
  OCTET STRING as alSumAlarms33to48  
  OCTET STRING as alSumAlarms49to64  
  OCTET STRING as alSumAlarms65to74  

AlarmCountersEntry  
SEQUENCE    
  INTEGER as alCntIndex  
  INTEGER as alCntAlarmPosition  
  INTEGER as alCntCount  

IoOptionIDEntry  
SEQUENCE    
  INTEGER as ioIDIndex  
  INTEGER as ioIDInstalledOptionSlot1  
  INTEGER as ioIDInstalledOptionSlot2  

IoConfigurationEntry  
SEQUENCE    
  INTEGER as iocIndex  
  INTEGER as iocPointNumber  
  IOPointLabel as iocLabel  
  OCTET STRING as iocStateOrValue  
  IOPointType as iocPointType  
  INTEGER as iocMode  
  INTEGER as iocType  
  OCTET STRING as iocCount  

IoStatusBitmapsEntry  
SEQUENCE    
  INTEGER as ioStatIndex  
  OCTET STRING as ioStatSummaryBitmap  

MeterIdentificationEntry  
SEQUENCE    
  INTEGER as midIndex  
  INTEGER as midSerialNumber  
  OCTET STRING as midFirmwareVersion  
  OCTET STRING as midModelNumber  
  OCTET STRING as midDeviceName