PowerNet-MIB

File: PowerNet-MIB.mib (2255207 bytes)

Imported modules

SNMPv2-SMI RFC1155-SMI RFC1213-MIB
RFC-1212 RFC-1215

Imported symbols

Integer32 enterprises IpAddress
Gauge TimeTicks DisplayString
OBJECT-TYPE TRAP-TYPE

Defined Objects

apc 1.3.6.1.4.1.318
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.318.1
OBJECT IDENTIFIER    

communicationLost 1.3.6.1.4.1.318.1
SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress.
TRAP-TYPE    
  mtrapargsString  

hardware 1.3.6.1.4.1.318.1.1
OBJECT IDENTIFIER    

ups 1.3.6.1.4.1.318.1.1.1
OBJECT IDENTIFIER    

upsIdent 1.3.6.1.4.1.318.1.1.1.1
OBJECT IDENTIFIER    

upsBasicIdent 1.3.6.1.4.1.318.1.1.1.1.1
OBJECT IDENTIFIER    

upsBasicIdentModel 1.3.6.1.4.1.318.1.1.1.1.1.1
The UPS model name (e.g. 'APC Smart-UPS 600').
OBJECT-TYPE    
  DisplayString  

upsBasicIdentName 1.3.6.1.4.1.318.1.1.1.1.1.2
An 8 byte ID string identifying the UPS. This object can be set by the administrator.
OBJECT-TYPE    
  DisplayString  

upsAdvIdent 1.3.6.1.4.1.318.1.1.1.1.2
OBJECT IDENTIFIER    

upsAdvIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.1.1.2.1
The firmware revision of the UPS system's microprocessor.
OBJECT-TYPE    
  DisplayString  

upsAdvIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.1.1.2.2
The date when the UPS was manufactured in mm/dd/yy (or yyyy) format.
OBJECT-TYPE    
  DisplayString  

upsAdvIdentSerialNumber 1.3.6.1.4.1.318.1.1.1.1.2.3
An 8-character string identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspond to the serial number on the rear of the UPS.
OBJECT-TYPE    
  DisplayString  

upsAdvIdentFirmwareRevision2 1.3.6.1.4.1.318.1.1.1.1.2.4
The firmware revision of a UPS system co-microprocessor.
OBJECT-TYPE    
  DisplayString  

upsAdvIdentSkuNumber 1.3.6.1.4.1.318.1.1.1.1.2.5
The SKU number of a UPS system.
OBJECT-TYPE    
  DisplayString  

upsBattery 1.3.6.1.4.1.318.1.1.1.2
OBJECT IDENTIFIER    

upsBasicBattery 1.3.6.1.4.1.318.1.1.1.2.1
OBJECT IDENTIFIER    

upsBasicBatteryStatus 1.3.6.1.4.1.318.1.1.1.2.1.1
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime.
OBJECT-TYPE    
  INTEGER unknown(1), batteryNormal(2), batteryLow(3)  

upsBasicBatteryTimeOnBattery 1.3.6.1.4.1.318.1.1.1.2.1.2
The elapsed time since the UPS has switched to battery power.
OBJECT-TYPE    
  TimeTicks  

upsBasicBatteryLastReplaceDate 1.3.6.1.4.1.318.1.1.1.2.1.3
The date when the UPS system's batteries were last replaced in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator. For Symmetra PX 250/500 this OID is read only and is configurable in the local display only.
OBJECT-TYPE    
  DisplayString  

upsAdvBattery 1.3.6.1.4.1.318.1.1.1.2.2
OBJECT IDENTIFIER    

upsAdvBatteryCapacity 1.3.6.1.4.1.318.1.1.1.2.2.1
The remaining battery capacity expressed in percent of full capacity.
OBJECT-TYPE    
  Gauge  

upsAdvBatteryTemperature 1.3.6.1.4.1.318.1.1.1.2.2.2
The current internal UPS temperature expressed in Celsius.
OBJECT-TYPE    
  Gauge  

upsAdvBatteryRunTimeRemaining 1.3.6.1.4.1.318.1.1.1.2.2.3
The UPS battery run time remaining before battery exhaustion.
OBJECT-TYPE    
  TimeTicks  

upsAdvBatteryReplaceIndicator 1.3.6.1.4.1.318.1.1.1.2.2.4
Indicates whether the UPS batteries need replacing.
OBJECT-TYPE    
  INTEGER noBatteryNeedsReplacing(1), batteryNeedsReplacing(2)  

upsAdvBatteryNumOfBattPacks 1.3.6.1.4.1.318.1.1.1.2.2.5
The number of external battery packs connected to the UPS. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryNumOfBadBattPacks 1.3.6.1.4.1.318.1.1.1.2.2.6
The number of external battery packs connected to the UPS that are defective. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryNominalVoltage 1.3.6.1.4.1.318.1.1.1.2.2.7
The nominal battery voltage in Volts.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryActualVoltage 1.3.6.1.4.1.318.1.1.1.2.2.8
The actual battery bus voltage in Volts.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryCurrent 1.3.6.1.4.1.318.1.1.1.2.2.9
The battery current in Amps.
OBJECT-TYPE    
  INTEGER  

upsAdvTotalDCCurrent 1.3.6.1.4.1.318.1.1.1.2.2.10
The total DC current in Amps.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryFullCapacity 1.3.6.1.4.1.318.1.1.1.2.2.11
The full chargeable capacity of the battery which is expressed in percentage.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryActualVoltageTable 1.3.6.1.4.1.318.1.1.1.2.2.12
A list of battery table entries. The number of battery frames present in UPS.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSAdvBatteryActualVoltageEntry

upsAdvBatteryActualVoltageEntry 1.3.6.1.4.1.318.1.1.1.2.2.12.1
Information applicable to each of the Battery frames.
OBJECT-TYPE    
  UPSAdvBatteryActualVoltageEntry  

upsAdvBatteryActualVoltageTableIndex 1.3.6.1.4.1.318.1.1.1.2.2.12.1.1
The Battery Frame identifier. Battery Frame index.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryActualVoltagePolarity 1.3.6.1.4.1.318.1.1.1.2.2.12.1.2
The selected Battery Voltage Polarity. 0 indicates positive polarity. 1 indicates negative polarity.
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsAdvBatteryFrameActualVoltage 1.3.6.1.4.1.318.1.1.1.2.2.12.1.3
The actual battery bus voltage in Volts.
OBJECT-TYPE    
  INTEGER  

upsAdvTotalDCCurrentTable 1.3.6.1.4.1.318.1.1.1.2.2.13
A list of Battery Frame table entries. The number of entries is given by the value of Number of Battery Frames.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSAdvTotalDCCurrentEntry

upsAdvTotalDCCurrentEntry 1.3.6.1.4.1.318.1.1.1.2.2.13.1
An entry containing information applicable to a particular Battery Frame.
OBJECT-TYPE    
  UPSAdvTotalDCCurrentEntry  

upsAdvTotalDCCurrentTableIndex 1.3.6.1.4.1.318.1.1.1.2.2.13.1.1
The Battery Frame identifier. Total DC Current Table Index.
OBJECT-TYPE    
  INTEGER  

upsAdvTotalDCCurrentPolarity 1.3.6.1.4.1.318.1.1.1.2.2.13.1.2
The selected Battery Current Polarity. 0 indicates positive polarity. 1 indicates negative polarity.
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsAdvTotalFrameDCCurrent 1.3.6.1.4.1.318.1.1.1.2.2.13.1.3
The Total DC Current of battery in Amperes.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryCurrentTable 1.3.6.1.4.1.318.1.1.1.2.2.14
A list of Battery Frame table entries. The number of entries is given by number of Battery frames present.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSAdvBatteryCurrentEntry

upsAdvBatteryCurrentEntry 1.3.6.1.4.1.318.1.1.1.2.2.14.1
An entry containing information applicable to a particular battery frame.
OBJECT-TYPE    
  UPSAdvBatteryCurrentEntry  

upsAdvBatteryCurrentTableIndex 1.3.6.1.4.1.318.1.1.1.2.2.14.1.1
The Battery Frame identifier. Battery Current Table Index.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryCurrentIndex 1.3.6.1.4.1.318.1.1.1.2.2.14.1.2
The battery frame identifier.
OBJECT-TYPE    
  INTEGER  

upsAdvBatteryCurrentPolarity 1.3.6.1.4.1.318.1.1.1.2.2.14.1.3
The selected Battery current polarity. 0 indicates positive polarity. 1 indicates negative polarity
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsAdvBatteryFrameCurrent 1.3.6.1.4.1.318.1.1.1.2.2.14.1.4
The Battery current measured in Amperes
OBJECT-TYPE    
  INTEGER  

upsHighPrecBattery 1.3.6.1.4.1.318.1.1.1.2.3
OBJECT IDENTIFIER    

upsHighPrecBatteryCapacity 1.3.6.1.4.1.318.1.1.1.2.3.1
The remaining battery capacity expressed in tenths of percent of full capacity.
OBJECT-TYPE    
  Gauge  

upsHighPrecBatteryTemperature 1.3.6.1.4.1.318.1.1.1.2.3.2
The current internal UPS temperature expressed in tenths of degrees Celsius.
OBJECT-TYPE    
  Gauge  

upsHighPrecBatteryNominalVoltage 1.3.6.1.4.1.318.1.1.1.2.3.3
The nominal battery voltage in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryActualVoltage 1.3.6.1.4.1.318.1.1.1.2.3.4
The actual battery bus voltage in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryCurrent 1.3.6.1.4.1.318.1.1.1.2.3.5
The battery current in tenths of Amps.
OBJECT-TYPE    
  INTEGER  

upsHighPrecTotalDCCurrent 1.3.6.1.4.1.318.1.1.1.2.3.6
The total DC current in tenths of Amps.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryActualVoltageTable 1.3.6.1.4.1.318.1.1.1.2.3.7
A list of Battery frame table entries. The number of entries is given by the number of Battery frames.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSHighPrecBatteryActualVoltageEntry

upsHighPrecBatteryActualVoltageEntry 1.3.6.1.4.1.318.1.1.1.2.3.7.1
An entry containing information applicable to a particular battery frame.
OBJECT-TYPE    
  UPSHighPrecBatteryActualVoltageEntry  

upsHighPrecBatteryActualVoltageTableIndex 1.3.6.1.4.1.318.1.1.1.2.3.7.1.1
The Battery Frame identifier. High Precision Actual Voltage Table Index.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryActualVoltagePolarity 1.3.6.1.4.1.318.1.1.1.2.3.7.1.2
The selected Battery Voltage polarity. 0 indicates positive polarity. 1 indicates negative polarity.
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsHighPrecBatteryVoltage 1.3.6.1.4.1.318.1.1.1.2.3.7.1.3
The actual battery bus voltage expressed as tenths of Volts.
OBJECT-TYPE    
  INTEGER  

upsHighPrecTotalDCCurrentTable 1.3.6.1.4.1.318.1.1.1.2.3.8
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSHighPrecTotalDCCurrentEntry

upsHighPrecTotalDCCurrentEntry 1.3.6.1.4.1.318.1.1.1.2.3.8.1
An entry containing information applicable to a particular battery frame.
OBJECT-TYPE    
  UPSHighPrecTotalDCCurrentEntry  

upsHighPrecTotalDCCurrentTableIndex 1.3.6.1.4.1.318.1.1.1.2.3.8.1.1
The Battery Frame identifier. High precision Total DC Current index.
OBJECT-TYPE    
  INTEGER  

upsHighPrecTotalDCCurrentPolarity 1.3.6.1.4.1.318.1.1.1.2.3.8.1.2
The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity.
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsHighPrecTotalDCFrameCurrent 1.3.6.1.4.1.318.1.1.1.2.3.8.1.3
The total DC current in tenths of Amperes.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryCurrentTable 1.3.6.1.4.1.318.1.1.1.2.3.9
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
OBJECT-TYPE    
  SEQUENCE OF  
    UPSHighPrecBatteryCurrentEntry

upsHighPrecBatteryCurrentEntry 1.3.6.1.4.1.318.1.1.1.2.3.9.1
An entry containing information applicable to a particular battery frame.
OBJECT-TYPE    
  UPSHighPrecBatteryCurrentEntry  

upsHighPrecBatteryCurrentTableIndex 1.3.6.1.4.1.318.1.1.1.2.3.9.1.1
The Battery frame identifier. Battery Frame index.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryCurrentIndex 1.3.6.1.4.1.318.1.1.1.2.3.9.1.2
The Battery frame identifier. Battery Index for each frame.
OBJECT-TYPE    
  INTEGER  

upsHighPrecBatteryCurrentPolarity 1.3.6.1.4.1.318.1.1.1.2.3.9.1.3
The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity.
OBJECT-TYPE    
  INTEGER positive(0), negative(1)  

upsHighPrecBatteryFrameCurrent 1.3.6.1.4.1.318.1.1.1.2.3.9.1.4
The Battery current in tenths of Amperes.
OBJECT-TYPE    
  INTEGER  

upsInput 1.3.6.1.4.1.318.1.1.1.3
OBJECT IDENTIFIER    

upsBasicInput 1.3.6.1.4.1.318.1.1.1.3.1
OBJECT IDENTIFIER    

upsBasicInputPhase 1.3.6.1.4.1.318.1.1.1.3.1.1
The current AC input phase.
OBJECT-TYPE    
  INTEGER  

upsAdvInput 1.3.6.1.4.1.318.1.1.1.3.2
OBJECT IDENTIFIER    

upsAdvInputLineVoltage 1.3.6.1.4.1.318.1.1.1.3.2.1
The current utility line voltage in VAC.
OBJECT-TYPE    
  Gauge  

upsAdvInputMaxLineVoltage 1.3.6.1.4.1.318.1.1.1.3.2.2
The maximum utility line voltage in VAC over the previous 1 minute period.
OBJECT-TYPE    
  Gauge  

upsAdvInputMinLineVoltage 1.3.6.1.4.1.318.1.1.1.3.2.3
The minimum utility line voltage in VAC over the previous 1 minute period.
OBJECT-TYPE    
  Gauge  

upsAdvInputFrequency 1.3.6.1.4.1.318.1.1.1.3.2.4
The current input frequency to the UPS system in Hz.
OBJECT-TYPE    
  Gauge  

upsAdvInputLineFailCause 1.3.6.1.4.1.318.1.1.1.3.2.5
The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) -- if there is no transfer yet. - highLineVoltage(2) -- if the transfer to battery is caused by an over voltage greater than the high transfer voltage. - brownout(3) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - blackout(4) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. - smallMomentarySag(5) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - deepMomentarySag(6) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to - smallMomentarySpike(7) -- if the line failure is caused by a rate of change of input voltage less than ten volts per cycle. - largeMomentarySpike(8) -- if the line failure is caused by a rate of change of input voltage greater than ten volts per cycle. - selfTest(9) -- if the UPS was commanded to do a self test. - rateOfVoltageChange(10) -- if the failure is due to the rate of change of the line voltage.
OBJECT-TYPE    
  INTEGER noTransfer(1), highLineVoltage(2), brownout(3), blackout(4), smallMomentarySag(5), deepMomentarySag(6), smallMomentarySpike(7), largeMomentarySpike(8), selfTest(9), rateOfVoltageChange(10)  

upsAdvInputNominalFrequency 1.3.6.1.4.1.318.1.1.1.3.2.6
The nominal input frequency of the UPS system in Hz.
OBJECT-TYPE    
  INTEGER  

upsAdvInputNominalVoltage 1.3.6.1.4.1.318.1.1.1.3.2.7
The nominal input voltage of the UPS system in VAC.
OBJECT-TYPE    
  INTEGER  

upsAdvInputBypassNominalFrequency 1.3.6.1.4.1.318.1.1.1.3.2.8
The nominal bypass input frequency of the UPS system in Hz.
OBJECT-TYPE    
  INTEGER  

upsAdvInputBypassNominalVoltage 1.3.6.1.4.1.318.1.1.1.3.2.9
The nominal bypass input voltage of the UPS system in VAC.
OBJECT-TYPE    
  INTEGER  

upsAdvInputStatisticsTable 1.3.6.1.4.1.318.1.1.1.3.2.10
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsAdvInputStatisticsEntry

upsAdvInputStatisticsEntry 1.3.6.1.4.1.318.1.1.1.3.2.10.1
An entry containing information applicable to a particular input.
OBJECT-TYPE    
  UpsAdvInputStatisticsEntry  

upsAdvInputStatisticsIndex 1.3.6.1.4.1.318.1.1.1.3.2.10.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

upsAdvInputApparentPower 1.3.6.1.4.1.318.1.1.1.3.2.10.1.2
The input apparent power(sum of all of the three phases) measured in kVA.
OBJECT-TYPE    
  INTEGER  

upsAdvInputVoltageTHD 1.3.6.1.4.1.318.1.1.1.3.2.10.1.3
The input voltage Total Harmonic Distortion in percent.
OBJECT-TYPE    
  INTEGER  

upsAdvInputBypassVoltageTHD 1.3.6.1.4.1.318.1.1.1.3.2.10.1.4
The bypass input voltage Total Harmonic Distortion in percent.
OBJECT-TYPE    
  INTEGER  

upsAdvInputPeakCurrent 1.3.6.1.4.1.318.1.1.1.3.2.10.1.5
The input peak current in Amperes.
OBJECT-TYPE    
  INTEGER  

upsAdvInputBypassPeakCurrent 1.3.6.1.4.1.318.1.1.1.3.2.10.1.6
The bypass input peak current in Amperes.
OBJECT-TYPE    
  INTEGER  

upsHighPrecInput 1.3.6.1.4.1.318.1.1.1.3.3
OBJECT IDENTIFIER    

upsHighPrecInputLineVoltage 1.3.6.1.4.1.318.1.1.1.3.3.1
The current utility line voltage in tenths of VAC.
OBJECT-TYPE    
  Gauge  

upsHighPrecInputMaxLineVoltage 1.3.6.1.4.1.318.1.1.1.3.3.2
The maximum utility line voltage in tenths of VAC over the previous 1 minute period.
OBJECT-TYPE    
  Gauge  

upsHighPrecInputMinLineVoltage 1.3.6.1.4.1.318.1.1.1.3.3.3
The minimum utility line voltage in tenths of VAC over the previous 1 minute period.
OBJECT-TYPE    
  Gauge  

upsHighPrecInputFrequency 1.3.6.1.4.1.318.1.1.1.3.3.4
The current input frequency to the UPS system in tenths of Hz.
OBJECT-TYPE    
  Gauge  

upsOutput 1.3.6.1.4.1.318.1.1.1.4
OBJECT IDENTIFIER    

upsBasicOutput 1.3.6.1.4.1.318.1.1.1.4.1
OBJECT IDENTIFIER    

upsBasicOutputStatus 1.3.6.1.4.1.318.1.1.1.4.1.1
The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1).
OBJECT-TYPE    
  INTEGER unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13), hotStandby(14), onBatteryTest(15)  

upsBasicOutputPhase 1.3.6.1.4.1.318.1.1.1.4.1.2
The current output phase.
OBJECT-TYPE    
  INTEGER  

upsBasicSystemStatus 1.3.6.1.4.1.318.1.1.1.4.1.3
Current state for the whole system (UPS and surrounding breakers) If unable to determine the state of the system this variable is set to unknown(1).
OBJECT-TYPE    
  INTEGER unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13)  

upsBasicSystemInternalTemperature 1.3.6.1.4.1.318.1.1.1.4.1.4
The actual internal temperature of the UPS system in Celsius.
OBJECT-TYPE    
  INTEGER  

upsAdvOutput 1.3.6.1.4.1.318.1.1.1.4.2
OBJECT IDENTIFIER    

upsAdvOutputVoltage 1.3.6.1.4.1.318.1.1.1.4.2.1
The output voltage of the UPS system in VAC.
OBJECT-TYPE    
  Gauge  

upsAdvOutputFrequency 1.3.6.1.4.1.318.1.1.1.4.2.2
The current output frequency of the UPS system in Hz.
OBJECT-TYPE    
  Gauge  

upsAdvOutputLoad 1.3.6.1.4.1.318.1.1.1.4.2.3
The current UPS load expressed in percent of rated capacity.
OBJECT-TYPE    
  Gauge  

upsAdvOutputCurrent 1.3.6.1.4.1.318.1.1.1.4.2.4
The current in amperes drawn by the load on the UPS.
OBJECT-TYPE    
  Gauge  

upsAdvOutputRedundancy 1.3.6.1.4.1.318.1.1.1.4.2.5
The number of power modules which can fail or be removed without causing the UPS to generate a Minimum Redundancy Lost event.
OBJECT-TYPE    
  Gauge  

upsAdvOutputKVACapacity 1.3.6.1.4.1.318.1.1.1.4.2.6
The maximum load that this UPS can support.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputNominalFrequency 1.3.6.1.4.1.318.1.1.1.4.2.7
The nominal output frequency of the UPS system in Hz.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputActivePower 1.3.6.1.4.1.318.1.1.1.4.2.8
The total output active power of the UPS system in W. The total active power is the sum of phase 1, phase 2 and phase 3 power.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputApparentPower 1.3.6.1.4.1.318.1.1.1.4.2.9
The total output apparent power of all phases of the UPS system in VA.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputStatisticsTable 1.3.6.1.4.1.318.1.1.1.4.2.10
A list of input table entries. The number of entries is given by the value of upsPhaseNumOutputs.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsAdvOutputStatisticsEntry

upsAdvOutputStatisticsEntry 1.3.6.1.4.1.318.1.1.1.4.2.10.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  UpsAdvOutputStatisticsEntry  

upsAdvOutputStatisticsIndex 1.3.6.1.4.1.318.1.1.1.4.2.10.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputPeakCurrent 1.3.6.1.4.1.318.1.1.1.4.2.10.1.2
The output peak current in Amperes.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputCurrentTHD 1.3.6.1.4.1.318.1.1.1.4.2.10.1.3
The output current Total Harmonic Distortion in percent.
OBJECT-TYPE    
  INTEGER  

upsAdvOutputCrestFactor 1.3.6.1.4.1.318.1.1.1.4.2.10.1.4
The output current crest factor expressed in tenths.
OBJECT-TYPE    
  INTEGER  

upsHighPrecOutput 1.3.6.1.4.1.318.1.1.1.4.3
OBJECT IDENTIFIER    

upsHighPrecOutputVoltage 1.3.6.1.4.1.318.1.1.1.4.3.1
The output voltage of the UPS system in tenths of VAC.
OBJECT-TYPE    
  Gauge  

upsHighPrecOutputFrequency 1.3.6.1.4.1.318.1.1.1.4.3.2
The current output frequency of the UPS system in tenths of Hz.
OBJECT-TYPE    
  Gauge  

upsHighPrecOutputLoad 1.3.6.1.4.1.318.1.1.1.4.3.3
The current UPS load expressed in tenths of percent of rated capacity.
OBJECT-TYPE    
  Gauge  

upsHighPrecOutputCurrent 1.3.6.1.4.1.318.1.1.1.4.3.4
The current in tenths of amperes drawn by the load on the UPS.
OBJECT-TYPE    
  Gauge  

upsHighPrecOutputEfficiency 1.3.6.1.4.1.318.1.1.1.4.3.5
The efficiency of the UPS in tenths of percent. Result is -1 if UPS supports this oid but the result is not available.
OBJECT-TYPE    
  Integer32  

upsHighPrecOutputEnergyUsage 1.3.6.1.4.1.318.1.1.1.4.3.6
The output energy usage of the UPS in tenths of kWh.
OBJECT-TYPE    
  Gauge  

upsConfig 1.3.6.1.4.1.318.1.1.1.5
OBJECT IDENTIFIER    

upsBasicConfig 1.3.6.1.4.1.318.1.1.1.5.1
OBJECT IDENTIFIER    

upsBasicConfigNumDevices 1.3.6.1.4.1.318.1.1.1.5.1.1
The number of devices that are plugged into the UPS. This value is customer configurable from the device entry table
OBJECT-TYPE    
  INTEGER  

upsBasicConfigDeviceTable 1.3.6.1.4.1.318.1.1.1.5.1.2
A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBasicConfigNumDevices.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsBasicConfigDeviceEntry

upsBasicConfigDeviceEntry 1.3.6.1.4.1.318.1.1.1.5.1.2.1
The devices plugged in to the UPS.
OBJECT-TYPE    
  UpsBasicConfigDeviceEntry  

deviceIndex 1.3.6.1.4.1.318.1.1.1.5.1.2.1.1
The index of the device that is plugged into the UPS.
OBJECT-TYPE    
  INTEGER  

deviceName 1.3.6.1.4.1.318.1.1.1.5.1.2.1.2
The name/description of the device plugged into the UPS.
OBJECT-TYPE    
  DisplayString  

vaRating 1.3.6.1.4.1.318.1.1.1.5.1.2.1.3
The volt-amp rating of the device plugged into the UPS.
OBJECT-TYPE    
  INTEGER  

acceptThisDevice 1.3.6.1.4.1.318.1.1.1.5.1.2.1.4
An entry is added if yes, the entry is deleted if no.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsAdvConfig 1.3.6.1.4.1.318.1.1.1.5.2
OBJECT IDENTIFIER    

upsAdvConfigRatedOutputVoltage 1.3.6.1.4.1.318.1.1.1.5.2.1
The nominal output voltage from the UPS in VAC. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigHighTransferVolt 1.3.6.1.4.1.318.1.1.1.5.2.2
The maximum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigLowTransferVolt 1.3.6.1.4.1.318.1.1.1.5.2.3
The minimum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigAlarm 1.3.6.1.4.1.318.1.1.1.5.2.4
A flag indicating how the UPS should handle audible line fail alarms: timed(1): UPS alarm will sound after a preset timed duration starting from the line fail condition (see OID upsAdvConfigAlarmTimer for the alarm timer value) atLowBattery(2): UPS alarm will sound when the UPS has reached a Low Battery condition during a line fail never(3): Disables the UPS audible alarm mute(4): Mutes the current alarm for some UPSs only when it is in an alarm state and will return to the previously configured option when the UPS recovers from the alarm condition
OBJECT-TYPE    
  INTEGER timed(1), atLowBattery(2), never(3), mute(4)  

upsAdvConfigAlarmTimer 1.3.6.1.4.1.318.1.1.1.5.2.5
The time after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observed only if the value of extControlAlarm is timed(2). Allowed values are 0 or 30 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigMinReturnCapacity 1.3.6.1.4.1.318.1.1.1.5.2.6
The minimum battery capacity required before the UPS will return from a low battery shutdown condition. The capacity is measured from 0% battery capacity (or Low Battery) as a percent of full capacity (100%). In other words, the UPS will not re-energize the output until the battery has charged so that its' capacity is equal to this value. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigSensitivity 1.3.6.1.4.1.318.1.1.1.5.2.7
The sensitivity of the UPS to utility line abnormalities or noises.
OBJECT-TYPE    
  INTEGER auto(1), low(2), medium(3), high(4)  

upsAdvConfigLowBatteryRunTime 1.3.6.1.4.1.318.1.1.1.5.2.8
The desired run time of the UPS, in seconds, once the low battery condition is reached. During this time the UPS will produce a constant warning tone which can not be disabled. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets the value as the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigReturnDelay 1.3.6.1.4.1.318.1.1.1.5.2.9
The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UPS wakes up from 'sleep' mode. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigShutoffDelay 1.3.6.1.4.1.318.1.1.1.5.2.10
The delay in seconds the UPS remains on after being told to turn off. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigUpsSleepTime 1.3.6.1.4.1.318.1.1.1.5.2.11
The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 1/10 of an hour increments. The provided value will be rounded to the closest 1/10 of an hour with one exception: Any value entered between 1 and 540 seconds will be rounded to 360 seconds (or 6 minutes).
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigSetEEPROMDefaults 1.3.6.1.4.1.318.1.1.1.5.2.12
WRITE: Resets the UPS EEPROM variables to default values. READ: returns 0
OBJECT-TYPE    
  INTEGER noSetEEPROMDefaults(1), setEEPROMDefaults(2)  

upsAdvConfigDipSwitchTable 1.3.6.1.4.1.318.1.1.1.5.2.13
Current settings of UPS dip switches.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsAdvConfigDipSwitchEntry

upsAdvConfigDipSwitchEntry 1.3.6.1.4.1.318.1.1.1.5.2.13.1
The current setting of one dip switch.
OBJECT-TYPE    
  UpsAdvConfigDipSwitchEntry  

dipSwitchIndex 1.3.6.1.4.1.318.1.1.1.5.2.13.1.1
The index of a UPS dip switch.
OBJECT-TYPE    
  INTEGER  

dipSwitchStatus 1.3.6.1.4.1.318.1.1.1.5.2.13.1.2
The setting of a UPS dip switch.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

upsAdvConfigBattExhaustThresh 1.3.6.1.4.1.318.1.1.1.5.2.14
The number of seconds prior to battery exhaustion when the UPS will switch off power to its load.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigPassword 1.3.6.1.4.1.318.1.1.1.5.2.15
The password entered at the UPS front panel to enable local configuration of the EEProm. If the password is disabled or is not supported, then the agent returns a null string.
OBJECT-TYPE    
  DisplayString  

upsAdvConfigAllowedSetTable 1.3.6.1.4.1.318.1.1.1.5.2.16
The table listing the allowed values for all discrete configurable UPS variables.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsAdvConfigAllowedSetEntry

upsAdvConfigAllowedSetEntry 1.3.6.1.4.1.318.1.1.1.5.2.16.1
The table entry for a configurable UPS variable.
OBJECT-TYPE    
  UpsAdvConfigAllowedSetEntry  

apcUpsConfigFieldIndex 1.3.6.1.4.1.318.1.1.1.5.2.16.1.1
The index to an eeprom field entry.
OBJECT-TYPE    
  INTEGER  

apcUpsConfigFieldOID 1.3.6.1.4.1.318.1.1.1.5.2.16.1.2
The OID of the current configurable value.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

apcUpsConfigFieldValueRange 1.3.6.1.4.1.318.1.1.1.5.2.16.1.3
The discrete set of allowed values of a configurable register. Individual values are delimited by a comma.
OBJECT-TYPE    
  DisplayString  

upsAdvConfigBattCabAmpHour 1.3.6.1.4.1.318.1.1.1.5.2.17
Configure the amp-hour setting of the UPS battery cabinet.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigPositionSelector 1.3.6.1.4.1.318.1.1.1.5.2.18
Configure UPS position selector. If the UPS doesn't support this configuration it will report unknown (1). The positions are either rack (2) for rack mounted or tower (3) for tower unit.
OBJECT-TYPE    
  INTEGER unknown(1), rack(2), tower(3)  

upsAdvConfigOutputFreqRange 1.3.6.1.4.1.318.1.1.1.5.2.19
Configure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure the output frequency range for automatic. freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 % freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 % freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 % freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 % freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 % freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 % freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 % freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 % freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 % freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 % freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 % freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 % For a list of allowed values and conditions when variable can be set by your UPS model, see the UPS User's Manual.
OBJECT-TYPE    
  INTEGER unknown(1), freqRangeAUTO(2), freqRange60Var1(3), freqRange60Var3(4), freqRange50Var1(5), freqRange50Var3(6), freqRange60Var10(7), freqRange50Var10(8), freqRange60Var1dot0(9), freqRange50Var1dot0(10), freqRange50Pct0dot5(11), freqRange50Pct1(12), freqRange50Pct2(13), freqRange50Pct4(14), freqRange50Pct6(15), freqRange50Pct8(16), freqRange60Pct0dot5(17), freqRange60Pct1(18), freqRange60Pct2(19), freqRange60Pct4(20), freqRange60Pct6(21), freqRange60Pct8(22)  

upsAdvConfigUPSFail 1.3.6.1.4.1.318.1.1.1.5.2.20
Configure the UPS fail action. If UPS fails, and frequency or voltage is out of range it will either GotoBypass (2) or DropLoad (3). This OID will report unknown (1) if it is not supported feature or option.
OBJECT-TYPE    
  INTEGER unknown(1), gotoBypass(2), dropLoad(3)  

upsAdvConfigAlarmRedundancy 1.3.6.1.4.1.318.1.1.1.5.2.21
Configure settings of UPS alarm if the redundancy is under the current redundancy. Use 0 for never.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigAlarmLoadOver 1.3.6.1.4.1.318.1.1.1.5.2.22
Configure settings of UPS alarm if the load is over the current load in kVA. Use -1 for never.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigAlarmRuntimeUnder 1.3.6.1.4.1.318.1.1.1.5.2.23
Configure settings of UPS alarm if the runtime is under the current time of minutes. Use -1 for never.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigVoutReporting 1.3.6.1.4.1.318.1.1.1.5.2.24
Configure the way the UPS scales its output voltage readings. unknown(1) indicates the Vout Reporting is unknown. voutAUTO(2) configure the Vout Reporting for automatic scaling. vout208(3) configure the Vout Reporting for 208 Volts. vout240(4) configure the Vout Reporting for 240 Volts.
OBJECT-TYPE    
  INTEGER unknown(1), voutAUTO(2), vout208(3), vout240(4)  

upsAdvConfigNumExternalBatteries 1.3.6.1.4.1.318.1.1.1.5.2.25
Configure the number of external batteries connected to the UPS.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigSimpleSignalShutdowns 1.3.6.1.4.1.318.1.1.1.5.2.26
Configure Simple Signal shutdown commands from the Simple Signal port to be issued to the UPS. unknown(1) indicates the Simple Signal Shutdown setting is unknown. disabled(2) configure to disable Simple Signal Shutdowns. enabled(3) configure to enable Simple Signal Shutdowns.
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

upsAdvConfigMaxShutdownTime 1.3.6.1.4.1.318.1.1.1.5.2.27
The maximum amount of time for server shutdown to complete before a UPS shutdown occurs.
OBJECT-TYPE    
  INTEGER  

upsAsiUpsControlServerRequestShutdown 1.3.6.1.4.1.318.1.1.1.5.2.28
Start a server shutdown sequence: serverShutdownOff: Shutdown server and turn off UPS serverShutdownReboot: Shutdown server and turn reboot UPS.
OBJECT-TYPE    
  INTEGER serverShutdownOff(1), serverShutdownReboot(2)  

upsAdvConfigMinReturnRuntime 1.3.6.1.4.1.318.1.1.1.5.2.29
The minimum amount of run time in seconds required before the output will be turned on, using power calculation captured at start of last shutdown.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigBasicSignalLowBatteryDuration 1.3.6.1.4.1.318.1.1.1.5.2.30
The duration of runtime in seconds during an on-battery condition at which the UPS will signal the basic low battery shutdown condition.
OBJECT-TYPE    
  TimeTicks  

upsAdvConfigBypassPhaseLockRequired 1.3.6.1.4.1.318.1.1.1.5.2.31
Sets the condition for when bypass is an acceptable mode of operation as a requirement.
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

upsAdvConfigOutputFreqSlewRate 1.3.6.1.4.1.318.1.1.1.5.2.32
The rate at which the UPS will change its output frequency in response to utility frequency changes.
OBJECT-TYPE    
  INTEGER unknown(1), slewRateQuarterHzPerSec(2), slewRateHalfHzPerSec(3), slewRate1HzPerSec(4), slewRate2HzPerSec(5), slewRate4HzPerSec(6), slewRate6HzPerSec(7)  

upsAdvConfigChargerLevel 1.3.6.1.4.1.318.1.1.1.5.2.33
Sets the rate at which the UPS charges its batteries.
OBJECT-TYPE    
  INTEGER unknown(1), low(2), high(3)  

upsAdvConfigBypassToleranceSetting 1.3.6.1.4.1.318.1.1.1.5.2.34
This setting allows selecting from standard bypass tolerance configurations to suit their situation.
OBJECT-TYPE    
  INTEGER unknown(1), wide(2), medium(3), narrow(4), custom(5)  

upsAdvConfigMainsSetting 1.3.6.1.4.1.318.1.1.1.5.2.35
Configure the type of mains supply system. singleInput (1) indicates a single supply system. dualInput (2) indicates a dual supply system.
OBJECT-TYPE    
  INTEGER singleInput(1), dualInput(2)  

upsAdvConfigACWiringSetting 1.3.6.1.4.1.318.1.1.1.5.2.36
Configure the AC wiring of the system. threeWire (1) indicates 3-wire system configuration. fourWire (2) indicates 4-wire system configuration.
OBJECT-TYPE    
  INTEGER threeWire(1), fourWire(2)  

upsAdvConfigUpperOutputVoltTolerance 1.3.6.1.4.1.318.1.1.1.5.2.37
Upper tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage.
OBJECT-TYPE    
  INTEGER 0..100  

upsAdvConfigLowerOutputVoltTolerance 1.3.6.1.4.1.318.1.1.1.5.2.38
Lower tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage.
OBJECT-TYPE    
  INTEGER 0..100  

upsAdvConfigUpperBypassVoltTolerance 1.3.6.1.4.1.318.1.1.1.5.2.39
Upper tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage.
OBJECT-TYPE    
  INTEGER 0..100  

upsAdvConfigLowerBypassVoltTolerance 1.3.6.1.4.1.318.1.1.1.5.2.40
Lower tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage.
OBJECT-TYPE    
  INTEGER 0..100  

upsAdvConfigOutofSyncBypassTransferDelay 1.3.6.1.4.1.318.1.1.1.5.2.41
Configure the time (in milliseconds), indicating the gap in output voltage if an asynchronous transfer to bypass needs to occur.
OBJECT-TYPE    
  INTEGER  

upsAdvConfigWarningAlarmDelay 1.3.6.1.4.1.318.1.1.1.5.2.43
Configure the time delay for reporting warning alarms (in seconds).
OBJECT-TYPE    
  INTEGER  

upsAdvConfigInformationalAlarmDelay 1.3.6.1.4.1.318.1.1.1.5.2.44
Configure the time delay for reporting informational alarms (in seconds).
OBJECT-TYPE    
  INTEGER  

upsControl 1.3.6.1.4.1.318.1.1.1.6
OBJECT IDENTIFIER    

upsBasicControl 1.3.6.1.4.1.318.1.1.1.6.1
OBJECT IDENTIFIER    

upsBasicControlConserveBattery 1.3.6.1.4.1.318.1.1.1.6.1.1
Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noTurnOffUps(1), turnOffUpsToConserveBattery(2)  

upsAdvControl 1.3.6.1.4.1.318.1.1.1.6.2
OBJECT IDENTIFIER    

upsAdvControlUpsOff 1.3.6.1.4.1.318.1.1.1.6.2.1
Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state. Setting this variable to turnUpsOffGracefully(3) causes the UPS to shut off after a delay period. This allows the host to shut down in a graceful manner. When in this state, the UPS will not provide output power regardless of the input line state. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOff(4) command will perform a Synchronized Turn Off of all active Group members regardless of their current AC output status. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5) command will perform a Synchronized Turn Off After Delay of all active Group members regardless of their current AC output status. This unit's Shutdown Delay will be used to execute the Turn Off After Delay command. If this UPS is an active member of an SCG, the turnUpsSyncGroupOffGracefully(6) command will perform a Synchronized Turn Off Gracefully of all active Group members regardless of their current AC output status. This unit's Maximum Shutdown Time and Shutdown Delay will be used to execute the Turn Off Gracefully command. Setting this value to noTurnUpsOff(1) has no effect. The value noTurnUpsOff(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noTurnUpsOff(1), turnUpsOff(2), turnUpsOffGracefully(3), turnUpsSyncGroupOff(4), turnUpsSyncGroupOffAfterDelay(5), turnUpsSyncGroupOffGracefully(6)  

upsAdvControlRebootShutdownUps 1.3.6.1.4.1.318.1.1.1.6.2.2
Setting this variable to rebootShutdownUps(2) causes the UPS to shut off and turn back on (as long as good AC input power is available, otherwise the UPS will remain off until good AC input power is available). Setting this variable to rebootShutdownUpsGracefully(3) causes the UPS to shut off after a delay period and then turn back on. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG) the rebootShutdownSyncGroupUps(4) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. If this UPS is an active member of a SCG the rebootShutdownSyncGroupUpsGracefully(5) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. Setting this value to noRebootShutdownUps(1) has no effect. The value noRebootShutdownUps(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noRebootShutdownUps(1), rebootShutdownUps(2), rebootShutdownUpsGracefully(3), rebootShutdownSyncGroupUps(4), rebootShutdownSyncGroupUpsGracefully(5)  

upsAdvControlUpsSleep 1.3.6.1.4.1.318.1.1.1.6.2.3
Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime. Setting this variable to putUpsToSleepGracefully(3) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime after a delay period. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG), the putUpsSyncGroupToSleep(4) command will perform a Synchronized Sleep of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Shutdown Delay, Sleep Time, and Return Delay will be used to execute the sleep command. If this UPS is an active member of a SCG the putUpsSyncGroupToSleepGracefully(5) command will perform a Synchronized Sleep Gracefully of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Sleep Time, and Return Delay to execute the sleep command. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. Setting this value to noPutUpsToSleep(1) has no effect. The value noPutUpsToSleep(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noPutUpsToSleep(1), putUpsToSleep(2), putUpsToSleepGracefully(3), putUpsSyncGroupToSleep(4), putUpsSyncGroupToSleepGracefully(5)  

upsAdvControlSimulatePowerFail 1.3.6.1.4.1.318.1.1.1.6.2.4
Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The value noSimulatePowerFailure(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noSimulatePowerFailure(1), simulatePowerFailure(2)  

upsAdvControlFlashAndBeep 1.3.6.1.4.1.318.1.1.1.6.2.5
Setting this variable to flashAndBeep(2) causes the UPS to beep and simultaneously turn on the UPS front panel lights (Smart-UPS only). If this UPS is an active member of a Synchronized Control Group (SCG), the flashAndBeepSyncGroup(3) command will Flash and Beep all active Group members regardless of current AC output status. Setting this value to noFlashAndBeep(1) has no effect. Setting this value to flashAndBeepCont (4) commandcauses the UPS to beep and light the front panel lights until the flashAndBeepCancel (5) command is received. The value noFlashAndBeep(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noFlashAndBeep(1), flashAndBeep(2), flashAndBeepSyncGroup(3), flashAndBeepCont(4), flashAndBeepCancel(5)  

upsAdvControlTurnOnUPS 1.3.6.1.4.1.318.1.1.1.6.2.6
Setting this variable to turnOnUPS(2) causes the UPS to be turned on immediately. If this UPS is an active member of a Synchronized Control Group (SCG), the turnOnUPSSyncGroup(3) command will perform a Synchronized Turn On of all active Group members regardless of their current AC output status. Setting this value to noTurnOnUPS(1) has no effect. The value noTurnOnUPS(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noTurnOnUPS(1), turnOnUPS(2), turnOnUPSSyncGroup(3)  

upsAdvControlBypassSwitch 1.3.6.1.4.1.318.1.1.1.6.2.7
This switch puts the UPS in or out of bypass mode.
OBJECT-TYPE    
  INTEGER noBypassSwitch(1), switchToBypass(2), switchOutOfBypass(3)  

upsAdvControlRebootUpsWithOrWithoutAC 1.3.6.1.4.1.318.1.1.1.6.2.8
Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2) causes the UPS to turn off immediately, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off immediately but will turn on based on their individual settings (to allow on sequencing). Setting this variable to rebootUpsDelayedWithOrWithoutAC (3) causes the UPS to turn off after a delay period, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off and on based on their individual settings (to allow off and/or on sequencing). Setting this value to noRebootUpsWithOrWithoutAC (1) has no effect. The value noRebootUpsWithOrWithoutAC (1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noRebootUpsWithOrWithoutAC(1), rebootUpsImmediatelyWithOrWithoutAC(2), rebootUpsDelayedWithOrWithoutAC(3)  

upsAdvControlFirmwareUpdate 1.3.6.1.4.1.318.1.1.1.6.2.9
Setting this variable to firmwareUpdate(2) causes the UPS to begin a firmware update if possible. Setting this value to noFirmwareUpdate(1) will clear the previous results, if any, or otherwise has no effect. Reading this variable will return noFirmwareUpdate(1) when the UPS firmware has not been updated (or previous results have been cleared), updateInProcess(3) when the UPS firmware is being updated, updateSuccessful(4) when the UPS firmware has been successfully updated, or updateFailed(5) if the UPS firmware update failed.
OBJECT-TYPE    
  INTEGER noFirmwareUpdate(1), firmwareUpdate(2), updateInProcess(3), updateSuccessful(4), updateFailed(5)  

upsTest 1.3.6.1.4.1.318.1.1.1.7
OBJECT IDENTIFIER    

upsBasicTest 1.3.6.1.4.1.318.1.1.1.7.1
OBJECT IDENTIFIER    

upsAdvTest 1.3.6.1.4.1.318.1.1.1.7.2
OBJECT IDENTIFIER    

upsAdvTestDiagnosticSchedule 1.3.6.1.4.1.318.1.1.1.7.2.1
The UPS system's automatic battery test schedule.
OBJECT-TYPE    
  INTEGER unknown(1), biweekly(2), weekly(3), atTurnOn(4), never(5), fourWeeks(6), twelveWeeks(7), biweeklySinceLastTest(8), weeklySinceLastTest(9)  

upsAdvTestDiagnostics 1.3.6.1.4.1.318.1.1.1.7.2.2
Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The value noTestDiagnostics(1) will always be returned when the variable is read.
OBJECT-TYPE    
  INTEGER noTestDiagnostics(1), testDiagnostics(2)  

upsAdvTestDiagnosticsResults 1.3.6.1.4.1.318.1.1.1.7.2.3
The results of the last UPS diagnostics test performed.
OBJECT-TYPE    
  INTEGER ok(1), failed(2), invalidTest(3), testInProgress(4)  

upsAdvTestLastDiagnosticsDate 1.3.6.1.4.1.318.1.1.1.7.2.4
The date the last UPS diagnostics test was performed in mm/dd/yy format.
OBJECT-TYPE    
  DisplayString  

upsAdvTestRuntimeCalibration 1.3.6.1.4.1.318.1.1.1.7.2.5
Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsAdvTestCalibrationResult.
OBJECT-TYPE    
  INTEGER noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3)  

upsAdvTestCalibrationResults 1.3.6.1.4.1.318.1.1.1.7.2.6
The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidCalibration(2) indicates last calibration did not take place since the battery capacity was below 100%. Value calibrationInProgress(3) means a calibration is occurring now.
OBJECT-TYPE    
  INTEGER ok(1), invalidCalibration(2), calibrationInProgress(3)  

upsAdvTestCalibrationDate 1.3.6.1.4.1.318.1.1.1.7.2.7
The date the last UPS runtime calibration was performed in mm/dd/yy format.
OBJECT-TYPE    
  DisplayString  

upsAdvTestDiagnosticTime 1.3.6.1.4.1.318.1.1.1.7.2.8
The time of the day to perform automatic battery test. Expressed in 24 hour notation - hh:mm.
OBJECT-TYPE    
  DisplayString  

upsAdvTestDiagnosticDay 1.3.6.1.4.1.318.1.1.1.7.2.9
The day of the week to perform automatic battery test.
OBJECT-TYPE    
  INTEGER monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)  

upsComm 1.3.6.1.4.1.318.1.1.1.8
OBJECT IDENTIFIER    

upsCommStatus 1.3.6.1.4.1.318.1.1.1.8.1
The status of agent's communication with UPS.
OBJECT-TYPE    
  INTEGER ok(1), noComm(2)  

upsPhase 1.3.6.1.4.1.318.1.1.1.9
OBJECT IDENTIFIER    

upsPhaseResetValues 1.3.6.1.4.1.318.1.1.1.9.1
OBJECT IDENTIFIER    

upsPhaseResetMaxMinValues 1.3.6.1.4.1.318.1.1.1.9.1.1
Reset the maximum and minimum UPS values: upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage, upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent, upsPhaseInputMaxPower, upsPhaseInputMinPower, upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent, upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad, upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad, upsPhaseOutputMaxPower, upsPhaseOutputMinPower, upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower.
OBJECT-TYPE    
  INTEGER none(1), reset(2)  

upsPhaseInput 1.3.6.1.4.1.318.1.1.1.9.2
OBJECT IDENTIFIER    

upsPhaseNumInputs 1.3.6.1.4.1.318.1.1.1.9.2.1
The number of input feeds to this device. This variable indicates the number of rows in the input table.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputTable 1.3.6.1.4.1.318.1.1.1.9.2.2
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsPhaseInputEntry

upsPhaseInputEntry 1.3.6.1.4.1.318.1.1.1.9.2.2.1
An entry containing information applicable to a particular input.
OBJECT-TYPE    
  UpsPhaseInputEntry  

upsPhaseInputTableIndex 1.3.6.1.4.1.318.1.1.1.9.2.2.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseNumInputPhases 1.3.6.1.4.1.318.1.1.1.9.2.2.1.2
The number of input phases utilized in this device. The sum of all the upsPhaseNumInputPhases variable indicates the number of rows in the input phase table.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputVoltageOrientation 1.3.6.1.4.1.318.1.1.1.9.2.2.1.3
The input voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
OBJECT-TYPE    
  INTEGER unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)  

upsPhaseInputFrequency 1.3.6.1.4.1.318.1.1.1.9.2.2.1.4
The input frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputType 1.3.6.1.4.1.318.1.1.1.9.2.2.1.5
The input type.
OBJECT-TYPE    
  INTEGER unknown(1), main(2), bypass(3)  

upsPhaseInputName 1.3.6.1.4.1.318.1.1.1.9.2.2.1.6
A name given to a particular input.
OBJECT-TYPE    
  DisplayString  

upsPhaseInputPhaseTable 1.3.6.1.4.1.318.1.1.1.9.2.3
A list of input table entries. The number of entries is given by the sum of the upsPhaseNumInputPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsPhaseInputPhaseEntry

upsPhaseInputPhaseEntry 1.3.6.1.4.1.318.1.1.1.9.2.3.1
An entry containing information applicable to a particular input phase.
OBJECT-TYPE    
  UpsPhaseInputPhaseEntry  

upsPhaseInputPhaseTableIndex 1.3.6.1.4.1.318.1.1.1.9.2.3.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputPhaseIndex 1.3.6.1.4.1.318.1.1.1.9.2.3.1.2
The input phase identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputVoltage 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3
The input voltage in VAC, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMaxVoltage 1.3.6.1.4.1.318.1.1.1.9.2.3.1.4
The maximum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMinVoltage 1.3.6.1.4.1.318.1.1.1.9.2.3.1.5
The minimum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputCurrent 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6
The input current in 0.1 amperes, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMaxCurrent 1.3.6.1.4.1.318.1.1.1.9.2.3.1.7
The maximum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMinCurrent 1.3.6.1.4.1.318.1.1.1.9.2.3.1.8
The minimum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputPower 1.3.6.1.4.1.318.1.1.1.9.2.3.1.9
The input power in Watts, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMaxPower 1.3.6.1.4.1.318.1.1.1.9.2.3.1.10
The maximum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseInputMinPower 1.3.6.1.4.1.318.1.1.1.9.2.3.1.11
The minimum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutput 1.3.6.1.4.1.318.1.1.1.9.3
OBJECT IDENTIFIER    

upsPhaseNumOutputs 1.3.6.1.4.1.318.1.1.1.9.3.1
The number of output feeds to this device. This variable indicates the number of rows in the output table.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputTable 1.3.6.1.4.1.318.1.1.1.9.3.2
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsPhaseOutputEntry

upsPhaseOutputEntry 1.3.6.1.4.1.318.1.1.1.9.3.2.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  UpsPhaseOutputEntry  

upsPhaseOutputTableIndex 1.3.6.1.4.1.318.1.1.1.9.3.2.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseNumOutputPhases 1.3.6.1.4.1.318.1.1.1.9.3.2.1.2
The number of output phases utilized in this device. The sum of all the upsPhaseNumOutputPhases variable indicates the number of rows in the output phase table.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputVoltageOrientation 1.3.6.1.4.1.318.1.1.1.9.3.2.1.3
The output voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
OBJECT-TYPE    
  INTEGER unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)  

upsPhaseOutputFrequency 1.3.6.1.4.1.318.1.1.1.9.3.2.1.4
The output frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPhaseTable 1.3.6.1.4.1.318.1.1.1.9.3.3
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsPhaseOutputPhaseEntry

upsPhaseOutputPhaseEntry 1.3.6.1.4.1.318.1.1.1.9.3.3.1
An entry containing information applicable to a particular output phase.
OBJECT-TYPE    
  UpsPhaseOutputPhaseEntry  

upsPhaseOutputPhaseTableIndex 1.3.6.1.4.1.318.1.1.1.9.3.3.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPhaseIndex 1.3.6.1.4.1.318.1.1.1.9.3.3.1.2
The output phase identifier.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputVoltage 1.3.6.1.4.1.318.1.1.1.9.3.3.1.3
The output voltage in VAC, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputCurrent 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4
The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMaxCurrent 1.3.6.1.4.1.318.1.1.1.9.3.3.1.5
The maximum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMinCurrent 1.3.6.1.4.1.318.1.1.1.9.3.3.1.6
The minimum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7
The output load in VA, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMaxLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.8
The maximum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMinLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.9
The minimum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPercentLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.10
The percentage of the UPS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMaxPercentLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.11
The maximum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMinPercentLoad 1.3.6.1.4.1.318.1.1.1.9.3.3.1.12
The minimum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13
The output power in Watts, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMaxPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.14
The maximum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMinPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.15
The minimum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPercentPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16
The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMaxPercentPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.17
The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputMinPercentPower 1.3.6.1.4.1.318.1.1.1.9.3.3.1.18
The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
OBJECT-TYPE    
  INTEGER  

upsPhaseOutputPowerFactor 1.3.6.1.4.1.318.1.1.1.9.3.3.1.19
The Output power factor of the UPS in hundredth.
OBJECT-TYPE    
  INTEGER  

upsSyncCtrlGroup 1.3.6.1.4.1.318.1.1.1.10
OBJECT IDENTIFIER    

upsSyncCtrlGroupConfig 1.3.6.1.4.1.318.1.1.1.10.1
OBJECT IDENTIFIER    

upsSCGMembershipGroupNumber 1.3.6.1.4.1.318.1.1.1.10.1.1
The SCG Membership Group number (MGN) is a 16-bit number allowing up to 65534 separate groups that can be identified and distinguished per IP subnet. Zero and 65535 are not used. The MGN is used in all communication between members of the SCG and a Network Management Card (NMC) will listen and only respond to commands sent to it using its configured SCG ID.
OBJECT-TYPE    
  INTEGER  

upsSCGActiveMembershipStatus 1.3.6.1.4.1.318.1.1.1.10.1.2
Membership in the configured SCG can be enabled and disabled. If an NMC is configured for an SCG, but has its membership disabled, all synchronized control commands received will be ignored.
OBJECT-TYPE    
  INTEGER enabledSCG(1), disabledSCG(2)  

upsSCGPowerSynchronizationDelayTime 1.3.6.1.4.1.318.1.1.1.10.1.3
The Power Synchronization Delay Time (PSD) setting is the maximum number of seconds an SCG Initiator will wait for all SCG members to recover utility power before completing the reboot sequence of a reboot or sleep command. If all SCG members are ready to proceed, no additional delay is introduced.
OBJECT-TYPE    
  INTEGER  

upsSCGReturnBatteryCapacityOffset 1.3.6.1.4.1.318.1.1.1.10.1.4
A reboot command uses the Initiator's Return battery Capacity (RBC) to control when the SCG completes this operation. In a Normal Control Operation (NCC) the UPS will only complete the reboot if RBC is reached. Due to normal battery charge rate variations it may be desirable for the Followers to complete the reboot if they are within some range of the Initiator's RBC when the Initiator is prepared (charged to RBC) to complete the reboot. The Return Battery Capacity Offset (RBCO) defines a percent battery capacity subtracted from an RBC above which a Follower's battery must be charged for it to complete a reboot. For example, if the Initiator's RBC is 50% and the Initiator's RBCO is 5% then a Follower's battery capacity is within range if it is greater or equal to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot command. The default RBCO is 10%.
OBJECT-TYPE    
  INTEGER  

upsSCGMultiCastIP 1.3.6.1.4.1.318.1.1.1.10.1.5
The MultiCast IP address of the SCG Group.
OBJECT-TYPE    
  IpAddress  

upsSyncCtrlGroupStatus 1.3.6.1.4.1.318.1.1.1.10.2
OBJECT IDENTIFIER    

upsSCGNumOfGroupMembers 1.3.6.1.4.1.318.1.1.1.10.2.1
The number of active, communicating members in the Sync Control Group (SCG). This variable indicates the number of rows in the SCG Status Table.
OBJECT-TYPE    
  INTEGER  

upsSCGStatusTable 1.3.6.1.4.1.318.1.1.1.10.2.2
A list of SCG status table entries. The number of entries is given by the value of upsSCGNumOfGroupMembers.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsSCGStatusEntry

upsSCGStatusEntry 1.3.6.1.4.1.318.1.1.1.10.2.2.1
An entry containing information applicable to a particular SCG Member.
OBJECT-TYPE    
  UpsSCGStatusEntry  

upsSCGStatusTableIndex 1.3.6.1.4.1.318.1.1.1.10.2.2.1.1
The index of a status entry for an active, communicating SCG member.
OBJECT-TYPE    
  INTEGER  

upsSCGMemberIP 1.3.6.1.4.1.318.1.1.1.10.2.2.1.2
The IP address of an active, communicating SCG Member.
OBJECT-TYPE    
  IpAddress  

upsSCGACInputStatus 1.3.6.1.4.1.318.1.1.1.10.2.2.1.3
This OID indicates the AC Input Status of the SCG Member. acInGood(1) indicates the AC Input is within tolerance. acInBad(2) indicates the AC Input is not within tolerance.
OBJECT-TYPE    
  INTEGER acInGood(1), acInBad(2)  

upsSCGACOutputStatus 1.3.6.1.4.1.318.1.1.1.10.2.2.1.4
This OID indicates the AC Output Status of the SCG Member. acOutOn(1) indicates the UPS output is providing power to the load. acOutOff(2) indicates the UPS output is not providing power to the load.
OBJECT-TYPE    
  INTEGER acOutOn(1), acOutOff(2)  

upsState 1.3.6.1.4.1.318.1.1.1.11
OBJECT IDENTIFIER    

upsBasicState 1.3.6.1.4.1.318.1.1.1.11.1
OBJECT IDENTIFIER    

upsBasicStateOutputState 1.3.6.1.4.1.318.1.1.1.11.1.1
An ASCII string containing the 64 flags representing the current state(s) of the UPS. If the Network Card is unable to determine the state of the UPS, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 64, read from left to right. The flags are defined as follows: Flag 1: Abnormal Condition Present Flag 2: On Battery Flag 3: Low Battery Flag 4: On Line Flag 5: Replace Battery Flag 6: Serial Communication Established Flag 7: AVR Boost Active Flag 8: AVR Trim Active Flag 9: Overload Flag 10: Runtime Calibration Flag 11: Batteries Discharged Flag 12: Manual Bypass Flag 13: Software Bypass Flag 14: In Bypass due to Internal Fault Flag 15: In Bypass due to Supply Failure Flag 16: In Bypass due to Fan Failure Flag 17: Sleeping on a Timer Flag 18: Sleeping until Utility Power Returns Flag 19: On Flag 20: Rebooting Flag 21: Battery Communication Lost Flag 22: Graceful Shutdown Initiated Flag 23: Smart Boost or Smart Trim Fault Flag 24: Bad Output Voltage Flag 25: Battery Charger Failure Flag 26: High Battery Temperature Flag 27: Warning Battery Temperature Flag 28: Critical Battery Temperature Flag 29: Self Test In Progress Flag 30: Low Battery / On Battery Flag 31: Graceful Shutdown Issued by Upstream Device Flag 32: Graceful Shutdown Issued by Downstream Device Flag 33: No Batteries Attached Flag 34: Synchronized Command is in Progress Flag 35: Synchronized Sleeping Command is in Progress Flag 36: Synchronized Rebooting Command is in Progress Flag 37: Inverter DC Imbalance Flag 38: Transfer Relay Failure Flag 39: Shutdown or Unable to Transfer Flag 40: Low Battery Shutdown Flag 41: Electronic Unit Fan Failure Flag 42: Main Relay Failure Flag 43: Bypass Relay Failure Flag 44: Temporary Bypass Flag 45: High Internal Temperature Flag 46: Battery Temperature Sensor Fault Flag 47: Input Out of Range for Bypass Flag 48: DC Bus Overvoltage Flag 49: PFC Failure Flag 50: Critical Hardware Fault Flag 51: Green Mode/ECO Mode Flag 52: Hot Standby Flag 53: Emergency Power Off (EPO) Activated Flag 54: Load Alarm Violation Flag 55: Bypass Phase Fault Flag 56: UPS Internal Communication Failure Flag 57: Flag 58: Flag 59: Flag 60: Flag 61: Flag 62: Flag 63: Flag 64:
OBJECT-TYPE    
  DisplayString  

upsAdvState 1.3.6.1.4.1.318.1.1.1.11.2
OBJECT IDENTIFIER    

upsAdvStateAbnormalConditions 1.3.6.1.4.1.318.1.1.1.11.2.1
An ASCII string containing the 32 flags representing the current active UPS faults. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If this variable is not supported by the connected UPS, this variable is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: Flag 1: Power Module Failure Flag 2: Main Intelligence Module Failure Flag 3: Redundant Intelligence Module Failure Flag 4: Battery Failure Flag 5: Load(kVA) Alarm Threshold Violation Flag 6: Redundancy Lost Flag 7: Redundancy Below Alarm Threshold Flag 8: Bypass not in Range; Either Frequency or Voltage Flag 9: Bypass Contactor Stuck in Bypass Condition Flag 10: Bypass Contactor Stuck in On-Line Condition Flag 11: In Bypass due to an Internal Fault Flag 12: In Bypass due to an Overload Flag 13: In Maintenance Bypass Flag 14: Input Circuit Braker Tripped Open Flag 15: System Level Fan Failure Flag 16: Redundant Intelligent Module in Control Flag 17: IIC Inter-Module Communication Failure Flag 18: No Working Power Modules Flag 19: Load Shutdown From Bypass; Input Frequency Flag 20: Runtime Below Alarm Threshold Flag 21: Extended Run Frame Fault Flag 22: Output Voltage out of Range Flag 23: UPS Not Synchronized Flag 24: No Batteries Installed Flag 25: Battery Voltage High Flag 26: UPS Specific Fault Detected Flag 27: Site Wiring Fault Flag 28: Backfeed Protection Relay Opened Flag 29: Flag 30: Flag 31: Flag 32:
OBJECT-TYPE    
  DisplayString  

upsAdvStateSymmetra3PhaseSpecificFaults 1.3.6.1.4.1.318.1.1.1.11.2.2
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra 3-Phase UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: External Switch Gear Failure Flag 2: External Transformer Over Temperature Flag 3: External DC Circuit Breaker Tripped Flag 4: System Power Supply Failure Flag 5: Battery Monitor Card Failure Flag 6: Battery Monitor Card Removed Flag 7: XR Communication Card Failure Flag 8: XR Communication Card Removed Flag 9: External Switch Gear Monitoring Card Failure Flag 10: External Switch Gear Monitoring Card Removed Flag 11: Internal DC Circuit Breaker Tripped Flag 12: Static Bypass Switch Failure Flag 13: System EEPROM Removed Flag 14: System EEPROM Failure Flag 15: UPS in Forced Bypass Flag 16: Static Bypass Switch Module Removed Flag 17: System Start-Up Configuration Fault Flag 18: Battery Charger Shutdown Externally Flag 19: Flag 20: Flag 21: Flag 22: Flag 23: Flag 24: Flag 25: Flag 26: Flag 27: Flag 28: Flag 29: Flag 30: Flag 31: Flag 32: Flag 33: Flag 34: Flag 35: Flag 36: Flag 37: Flag 38: Flag 39: Flag 40: Flag 41: Flag 42: Flag 43: Flag 44: Flag 45: Flag 46: Flag 47: Flag 48: Flag 49: Flag 50: Flag 51: Flag 52: Flag 53: Flag 54: Flag 55: Flag 56: Flag 57: Flag 58: Flag 59: Flag 60: Flag 61: Flag 62: Flag 63: Flag 64:
OBJECT-TYPE    
  DisplayString  

upsAdvStateDP300ESpecificFaults 1.3.6.1.4.1.318.1.1.1.11.2.3
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: Peak Current Limiter Active Flag 2: Bypass Power Supply Fault Flag 3: Delta Current Limiter Active Flag 4: Fan Fault Flag 5: High DC warning Flag 6: Inverter Voltage Error Flag 7: Parallel Synchronization Error Flag 8: Second Power Supply Fault Flag 9: Internal Power Supply Fault Flag 10: Flag 11: Flag 12: Flag 13: Flag 14: Bypass Static Switch High Temperature Flag 15: High Battery Temperature Flag 16: Battery Weak Flag 17: Flag 18: System Locked in Operation Mode Flag 19: RAM1 Memory Write Error Flag 20: Memory Write Error Flag 21: Communication to VQ Bypass Lost Flag 22: Communication to VQ Output Lost Flag 23: Communication to DMU Lost Flag 24: Communication to Controller Lost Flag 25: Communication to Parallel IF Lost Flag 26: External Shutdown Accepted Flag 27: DC Capacitor Charge Error Flag 28: Communication to VQ Mains Lost Flag 29: Bypass Synchronization Error Flag 30: Charge Error Flag 31: SII Aux Input Activiated Flag 32: Flag 33: Blown Inverter Fuse Flag 34: Blown Rectifier Fuse Flag 35: Auxilliary 1 Fault Flag 36: Flag 37: Flag 38: Flag 39: Flag 40: Flag 41: Flag 42: Flag 43: Flag 44: Flag 45: Flag 46: High Temperature Charger Magnetic Flag 47: Flag 48: Battery Monitor Warning Flag 49: Battery Monitor Alarm Flag 50: Flag 51: Flag 52: Flag 53: TSM 1/2/3 Temperature Shutdown Flag 54: Charger 0/30 Temperature Warning Flag 55: Charger 0/30 Temperature Shutdown Flag 56: High Output Voltage Flag 57: SSW Temperature Over 90 Flag 58: Flag 59: Low Current Failure In AC Capacitors Flag 60: Flag 61: Advanced Battery Management Not Installed Flag 62: Flag 63: Flag 64:
OBJECT-TYPE    
  DisplayString  

upsAdvStateSymmetraSpecificFaults 1.3.6.1.4.1.318.1.1.1.11.2.4
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: System Fault Flag 2: Bypass Relay Fault Flag 3: Power Module Turn Off Failure Flag 4: Frame Identification Fault Flag 5: Flag 6: Flag 7: Flag 8: Flag 9: Flag 10: Flag 11: Flag 12: Flag 13: Flag 14: Flag 15: Flag 16: Flag 17: Flag 18: Flag 19: Flag 20: Flag 21: Flag 22: Flag 23: Flag 24: Flag 25: Flag 26: Flag 27: Flag 28: Flag 29: Flag 30: Flag 31: Flag 32: Flag 33: Flag 34: Flag 35: Flag 36: Flag 37: Flag 38: Flag 39: Flag 40: Flag 41: Flag 42: Flag 43: Flag 44: Flag 45: Flag 46: Flag 47: Flag 48: Flag 49: Flag 50: Flag 51: Flag 52: Flag 53: Flag 54: Flag 55: Flag 56: Flag 57: Flag 58: Flag 59: Flag 60: Flag 61: Flag 62: Flag 63: Flag 64:
OBJECT-TYPE    
  DisplayString  

upsAdvStateSmartUPSSpecificFaults 1.3.6.1.4.1.318.1.1.1.11.2.5
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Smart-UPS UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: EPO Switch Activated Flag 2: Static Bypass Switch Fault Flag 3: System Configuration Fault Flag 4: Power Supply Unit Fault Flag 5: Weak Battery Flag 6: High Battery Temperature Flag 7: Internal Mechanical Bypass Flag 8: Loss Of Parallel Redundancy Flag 9: Parallel Bus Communication Fault on Cable 1 Flag 10: Parallel Bus Communication Fault on Cable 2 Flag 11: Auxiliary Bus Communication Fault Flag 12: Parallel Bus Termination Fault on Cable 1 Flag 13: Parallel Bus Termination Fault on Cable 2 Flag 14: Auxiliary Bus Termination Fault Flag 15: No Master Present In The Parallel System Flag 16: Overload on a Parallel Unit Flag 17: Parallel Configuration Fault Flag 18: Flag 19: Flag 20: Flag 21: Flag 22: Flag 23: Flag 24: Flag 25: Flag 26: Flag 27: Flag 28: Flag 29: Flag 30: Flag 31: Flag 32: Flag 33: Flag 34: Flag 35: Flag 36: Flag 37: Flag 38: Flag 39: Flag 40: Flag 41: Flag 42: Flag 43: Flag 44: Flag 45: Flag 46: Flag 47: Flag 48: Flag 49: Flag 50: Flag 51: Flag 52: Flag 53: Flag 54: Flag 55: Flag 56: Flag 57: Flag 58: Flag 59: Flag 60: Flag 61: Flag 62: Flag 63: Flag 64:
OBJECT-TYPE    
  DisplayString  

upsAdvStateSystemMessages 1.3.6.1.4.1.318.1.1.1.11.2.6
An ASCII string containing the 3 digit Decimal code representing the current active message from the System Message Register. Each code should remain active for a minimum of 15 seconds. However, in the worst case scenario, a code could be cleared after only 5 seconds. It is recommended that this object be polled at least once every 4 seconds in order to get the most accurate representation of the current UPS System Message. If the Network Card is unable to determine the value of the System Message Register, this variable is set to 'UNKNOWN'.
OBJECT-TYPE    
  DisplayString  

upsAdvStateTotaltimeonbattery 1.3.6.1.4.1.318.1.1.1.11.2.7
Total time the UPS has been in battery operation.
OBJECT-TYPE    
  DisplayString  

upsAdvStateTotaltimeonbypass 1.3.6.1.4.1.318.1.1.1.11.2.8
Total time the UPS has been in bypass operation.
OBJECT-TYPE    
  DisplayString  

upsAdvStateTotaltimeonNormal 1.3.6.1.4.1.318.1.1.1.11.2.9
Total time the UPS has been in normal operation.
OBJECT-TYPE    
  DisplayString  

upsAdvStateNumberoftimesonbattery 1.3.6.1.4.1.318.1.1.1.11.2.10
Number of times the UPS was on battery. Since the last reset of statistical data.
OBJECT-TYPE    
  INTEGER  

upsAdvStateNumberoftimesbypass 1.3.6.1.4.1.318.1.1.1.11.2.11
Number of times the UPS was in bypass. Since the last reset of statistical data.
OBJECT-TYPE    
  INTEGER  

upsAdvStateNumberoftimesNormal 1.3.6.1.4.1.318.1.1.1.11.2.12
Number of times the UPS was in normal operation. Since the last reset of statistical data.
OBJECT-TYPE    
  INTEGER  

upsAdvStateEcomode 1.3.6.1.4.1.318.1.1.1.11.2.13
Eco mode status. 1: UPS is on Eco-mode 2: UPS is not on Eco-mode.
OBJECT-TYPE    
  INTEGER upsOnEcoMode(1), upsNotOnEcoMode(2)  

upsOutletGroups 1.3.6.1.4.1.318.1.1.1.12
OBJECT IDENTIFIER    

upsOutletGroupStatus 1.3.6.1.4.1.318.1.1.1.12.1
OBJECT IDENTIFIER    

upsOutletGroupStatusTableSize 1.3.6.1.4.1.318.1.1.1.12.1.1
The number of outlet groups for the UPS.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupStatusTable 1.3.6.1.4.1.318.1.1.1.12.1.2
Allows for getting status of the outlet groups. The number of entries is contained in the upsOutletGroupStatusTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsOutletGroupStatusEntry

upsOutletGroupStatusEntry 1.3.6.1.4.1.318.1.1.1.12.1.2.1
The outlet group status to get.
OBJECT-TYPE    
  UpsOutletGroupStatusEntry  

upsOutletGroupStatusIndex 1.3.6.1.4.1.318.1.1.1.12.1.2.1.1
The index to the outlet group entry.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupStatusName 1.3.6.1.4.1.318.1.1.1.12.1.2.1.2
The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID.
OBJECT-TYPE    
  DisplayString  

upsOutletGroupStatusGroupState 1.3.6.1.4.1.318.1.1.1.12.1.2.1.3
Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupStatusOn (1) value will be returned. If the outlet group is off, the upsOutletGroupStatusOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupStatusUnknown (3) value will be returned.
OBJECT-TYPE    
  INTEGER upsOutletGroupStatusOn(1), upsOutletGroupStatusOff(2), upsOutletGroupStatusUnknown(3)  

upsOutletGroupStatusCommandPending 1.3.6.1.4.1.318.1.1.1.12.1.2.1.4
Getting this variable will return the command pending state of the outlet group. If a command is pending on the outlet group, the upsOutletGroupCommandPending (1) value will be returned. If there is not a command pending on the outlet group, the upsOutletGroupNoCommandPending (2) will be returned.
OBJECT-TYPE    
  INTEGER upsOutletGroupCommandPending(1), upsOutletGroupNoCommandPending(2)  

upsOutletGroupStatusOutletType 1.3.6.1.4.1.318.1.1.1.12.1.2.1.5
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
OBJECT-TYPE    
  INTEGER upsSwitchedOutletGroup(1), upsMainOutletGroup(2)  

upsOutletGroupConfig 1.3.6.1.4.1.318.1.1.1.12.2
OBJECT IDENTIFIER    

upsOutletGroupConfigTableSize 1.3.6.1.4.1.318.1.1.1.12.2.1
The number of outlet groups for the UPS.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigTable 1.3.6.1.4.1.318.1.1.1.12.2.2
The list of outlet groups to configure. The number of entries is defined by the upsOutletGroupConfigTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsOutletGroupConfigEntry

upsOutletGroupConfigEntry 1.3.6.1.4.1.318.1.1.1.12.2.2.1
The outlet groups to configure.
OBJECT-TYPE    
  UpsOutletGroupConfigEntry  

upsOutletGroupConfigIndex 1.3.6.1.4.1.318.1.1.1.12.2.2.1.1
The index to the outlet group entry.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigName 1.3.6.1.4.1.318.1.1.1.12.2.2.1.2
The name of the outlet group.
OBJECT-TYPE    
  DisplayString  

upsOutletGroupConfigPowerOnDelay 1.3.6.1.4.1.318.1.1.1.12.2.2.1.3
The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigPowerOffDelay 1.3.6.1.4.1.318.1.1.1.12.2.2.1.4
The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigRebootDuration 1.3.6.1.4.1.318.1.1.1.12.2.2.1.5
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turning the power off, at the start of the sequence, before initiating the power on sequence. Allowed values vary by UPS model.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigMinReturnRuntime 1.3.6.1.4.1.318.1.1.1.12.2.2.1.6
In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runtime (seconds) that is required in order to power the Outlet Group on. Allowed values vary by UPS model.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigOutletType 1.3.6.1.4.1.318.1.1.1.12.2.2.1.7
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
OBJECT-TYPE    
  INTEGER upsSwitchedOutletGroup(1), upsMainOutletGroup(2)  

upsOutletGroupConfigLoadShedControlSkipOffDelay 1.3.6.1.4.1.318.1.1.1.12.2.2.1.8
Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situation, where applicable.
OBJECT-TYPE    
  INTEGER upsOutletGroupConfigSkipOffDelay(1), upsOutletGroupConfigUseOffDelay(2)  

upsOutletGroupConfigLoadShedControlAutoRestart 1.3.6.1.4.1.318.1.1.1.12.2.2.1.9
Configures whether the outlet group will automatically restart after a load shedding situation, where applicable.
OBJECT-TYPE    
  INTEGER upsOutletGroupConfigAutoRestart(1), upsOutletGroupConfigManualRestart(2)  

upsOutletGroupConfigLoadShedControlTimeOnBattery 1.3.6.1.4.1.318.1.1.1.12.2.2.1.10
Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition.
OBJECT-TYPE    
  INTEGER upsOutletGroupConfigDisableTimeOnBatteryLoadShed(1), upsOutletGroupConfigEnableTimeOnBatteryLoadShed(2)  

upsOutletGroupConfigLoadShedControlRuntimeRemaining 1.3.6.1.4.1.318.1.1.1.12.2.2.1.11
Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition.
OBJECT-TYPE    
  INTEGER upsOutletGroupConfigDisableRuntimeRemainingLoadShed(1), upsOutletGroupConfigEnableRuntimeRemainingLoadShed(2)  

upsOutletGroupConfigLoadShedControlInOverload 1.3.6.1.4.1.318.1.1.1.12.2.2.1.12
Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for this load shed condition. Returns -1 if not supported by this outlet group.
OBJECT-TYPE    
  INTEGER upsOutletGroupConfigDisableInOverloadLoadShed(1), upsOutletGroupConfigEnableInOverloadLoadShed(2)  

upsOutletGroupConfigLoadShedTimeOnBattery 1.3.6.1.4.1.318.1.1.1.12.2.2.1.13
When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery OID. Allowed values vary by UPS model.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupConfigLoadShedRuntimeRemaining 1.3.6.1.4.1.318.1.1.1.12.2.2.1.14
When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlRuntimeRemaining OID. Allowed values vary by UPS model.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupControl 1.3.6.1.4.1.318.1.1.1.12.3
OBJECT IDENTIFIER    

upsOutletGroupControlTableSize 1.3.6.1.4.1.318.1.1.1.12.3.1
The number of outlet groups for the UPS.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupControlTable 1.3.6.1.4.1.318.1.1.1.12.3.2
Allows for control of individual outlet groups. The number of entries is contained in the upsOutletGroupControlTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsOutletGroupControlEntry

upsOutletGroupControlEntry 1.3.6.1.4.1.318.1.1.1.12.3.2.1
The outlet group to control.
OBJECT-TYPE    
  UpsOutletGroupControlEntry  

upsOutletGroupControlIndex 1.3.6.1.4.1.318.1.1.1.12.3.2.1.1
The index to the outlet group entry.
OBJECT-TYPE    
  INTEGER  

upsOutletGroupControlName 1.3.6.1.4.1.318.1.1.1.12.3.2.1.2
The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID.
OBJECT-TYPE    
  DisplayString  

upsOutletGroupControlCommand 1.3.6.1.4.1.318.1.1.1.12.3.2.1.3
Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupImmediateOn (1) value will be returned. If the outlet group is off, the upsOutletGroupImmediateOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupControlUnknown (8) value will be returned. Setting this variable to upsOutletGroupImmediateOn (1) will turn the outlet group on immediately. Setting this variable to upsOutletGroupImmediateOff (2) will turn the outlet group off immediately. Setting this variable to upsOutletGroupImmediateRebootWithOrWithoutAC (3) will turn the outlet group off immediately, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedRebootWithOrWithoutAC (6) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupCancelPendingCommand (7) will cause any pending command to this outlet group to be canceled. Setting this variable to upsOutletGroupImmediateRebootShutdown (9) will turn the outlet group off immediately, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. Setting this variable to upsOutletGroupDelayedRebootShutdown (10) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. In systems with a main outlet group, commands to the main outlet group must be performed with caution. It may be clearer to use the ups control commands available from upsAdvControl... OIDs. If any command is made to the main outlet group that will turn it off, one of two things will happen: 1) If any switched outlet group is in a state that prevents this command from occurring on the main outlet group, the command will be rejected. Note that a switched outlet group being on without a command in progress is not a state that normally prevents the command. 2) The command will be accepted and applied to the main outlet group and all switched outlet groups that are on. There is one additional special case for systems with a main outlet group. If the main outlet group is off and a switched outlet group is commanded to turn on, the on command will be applied to both the main outlet group and that switched outlet group.
OBJECT-TYPE    
  INTEGER upsOutletGroupImmediateOn(1), upsOutletGroupImmediateOff(2), upsOutletGroupImmediateRebootWithOrWithoutAC(3), upsOutletGroupDelayedOn(4), upsOutletGroupDelayedOff(5), upsOutletGroupDelayedRebootWithOrWithoutAC(6), upsOutletGroupCancelPendingCommand(7), upsOutletGroupControlUnknown(8), upsOutletGroupImmediateRebootShutdown(9), upsOutletGroupDelayedRebootShutdown(10)  

upsOutletGroupControlOutletType 1.3.6.1.4.1.318.1.1.1.12.3.2.1.4
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
OBJECT-TYPE    
  INTEGER upsSwitchedOutletGroup(1), upsMainOutletGroup(2)  

upsDiagnostics 1.3.6.1.4.1.318.1.1.1.13
OBJECT IDENTIFIER    

upsDiagnosticIM 1.3.6.1.4.1.318.1.1.1.13.1
OBJECT IDENTIFIER    

upsDiagIMTableSize 1.3.6.1.4.1.318.1.1.1.13.1.1
The number of Intelligence Modules in or attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagIMTable 1.3.6.1.4.1.318.1.1.1.13.1.2
Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagIMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagIMEntry

upsDiagIMEntry 1.3.6.1.4.1.318.1.1.1.13.1.2.1
The diagnostics and information of an Intelligence Module.
OBJECT-TYPE    
  UpsDiagIMEntry  

upsDiagIMIndex 1.3.6.1.4.1.318.1.1.1.13.1.2.1.1
The index to the Intelligence Module entry.
OBJECT-TYPE    
  INTEGER  

upsDiagIMType 1.3.6.1.4.1.318.1.1.1.13.1.2.1.2
The type of the Intelligence Module. imUnknown(1) indicates the IM type is unknown. imMIM(2) indicates the IM type is a Main Intelligence Module. imRIM(3) indicates the IM type is Redundant Intelligence Module.
OBJECT-TYPE    
  INTEGER imUnknown(1), imMIM(2), imRIM(3)  

upsDiagIMStatus 1.3.6.1.4.1.318.1.1.1.13.1.2.1.3
The status of the Intelligence Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagIMFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.1.2.1.4
The firmware revision of the Intelligence Module.
OBJECT-TYPE    
  DisplayString  

upsDiagIMSlaveFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.1.2.1.5
The slave firmware revision of the Intelligence Module.
OBJECT-TYPE    
  DisplayString  

upsDiagIMHardwareRev 1.3.6.1.4.1.318.1.1.1.13.1.2.1.6
The hardware revision of the Intelligence Module.
OBJECT-TYPE    
  DisplayString  

upsDiagIMSerialNum 1.3.6.1.4.1.318.1.1.1.13.1.2.1.7
The serial number of the Intelligence Module.
OBJECT-TYPE    
  DisplayString  

upsDiagIMManufactureDate 1.3.6.1.4.1.318.1.1.1.13.1.2.1.8
The manufacture date of the Intelligence Module.
OBJECT-TYPE    
  DisplayString  

upsDiagnosticPowerModules 1.3.6.1.4.1.318.1.1.1.13.2
OBJECT IDENTIFIER    

upsDiagPMTableSize 1.3.6.1.4.1.318.1.1.1.13.2.1
The maximum number of Power Modules supported by the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagPMTable 1.3.6.1.4.1.318.1.1.1.13.2.2
Allows for diagnostics of Individual Power modules. The number of entries is contained in the upsDiagPMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagPMEntry

upsDiagPMEntry 1.3.6.1.4.1.318.1.1.1.13.2.2.1
The diagnostics of an Power Module.
OBJECT-TYPE    
  UpsDiagPMEntry  

upsDiagPMIndex 1.3.6.1.4.1.318.1.1.1.13.2.2.1.1
The index to the Power Module entry.
OBJECT-TYPE    
  INTEGER  

upsDiagPMStatus 1.3.6.1.4.1.318.1.1.1.13.2.2.1.2
The status of the Power Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagPMFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.2.2.1.3
The firmware revision of the Power Module.
OBJECT-TYPE    
  DisplayString  

upsDiagPMHardwareRev 1.3.6.1.4.1.318.1.1.1.13.2.2.1.4
The hardware revision of the Power Module.
OBJECT-TYPE    
  DisplayString  

upsDiagPMSerialNum 1.3.6.1.4.1.318.1.1.1.13.2.2.1.5
The serial number of the Power Module.
OBJECT-TYPE    
  DisplayString  

upsDiagPMManufactureDate 1.3.6.1.4.1.318.1.1.1.13.2.2.1.6
The manufacture date of the Power Module.
OBJECT-TYPE    
  DisplayString  

upsDiagnosticBatteries 1.3.6.1.4.1.318.1.1.1.13.3
OBJECT IDENTIFIER    

upsDiagBatteryTableSize 1.3.6.1.4.1.318.1.1.1.13.3.1
The maximum number of batteries supported by the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagBatteryTable 1.3.6.1.4.1.318.1.1.1.13.3.2
Allows for diagnostics of individual batteries. The number of entries is contained in the upsDiagBattTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagBatteryEntry

upsDiagBatteryEntry 1.3.6.1.4.1.318.1.1.1.13.3.2.1
The diagnostics of a battery.
OBJECT-TYPE    
  UpsDiagBatteryEntry  

upsDiagBatteryFrameIndex 1.3.6.1.4.1.318.1.1.1.13.3.2.1.1
The index to the battery frame entry. Frame 0 indicates the Main frame. Extended Run (XR) frames start from index 1.
OBJECT-TYPE    
  INTEGER  

upsDiagBatteryIndex 1.3.6.1.4.1.318.1.1.1.13.3.2.1.2
The index to the battery entry.
OBJECT-TYPE    
  INTEGER  

upsDiagBatteryStatus 1.3.6.1.4.1.318.1.1.1.13.3.2.1.3
The status of the battery. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the battery status is OK. failed(4) indicates the battery status is failed. highTemperature(5) indicates the battery has a high temperature condition. replaceImmediately(6) indicates the battery must be replaced immediately. lowCapacity(7) indicates the battery has a low capacity.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), failed(4), highTemperature(5), replaceImmediately(6), lowCapacity(7)  

upsDiagBatterySerialNumber 1.3.6.1.4.1.318.1.1.1.13.3.2.1.4
The serial number of the battery.
OBJECT-TYPE    
  DisplayString  

upsDiagBatteryFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.3.2.1.5
The firmware revision of the battery.
OBJECT-TYPE    
  DisplayString  

upsDiagBatteryManufactureDate 1.3.6.1.4.1.318.1.1.1.13.3.2.1.6
The manufacture date of the battery.
OBJECT-TYPE    
  DisplayString  

upsDiagBatteryType 1.3.6.1.4.1.318.1.1.1.13.3.2.1.7
The battery type or rating for the battery.
OBJECT-TYPE    
  DisplayString  

upsDiagnosticSubsystem 1.3.6.1.4.1.318.1.1.1.13.4
OBJECT IDENTIFIER    

upsDiagSubSysFrameTableSize 1.3.6.1.4.1.318.1.1.1.13.4.1
The number of frames attached to the UPS including the Main frame.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysFrameTable 1.3.6.1.4.1.318.1.1.1.13.4.2
Allows for diagnostics of individual XR Frames.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysFrameEntry

upsDiagSubSysFrameEntry 1.3.6.1.4.1.318.1.1.1.13.4.2.1
The diagnostics of an XR Frame.
OBJECT-TYPE    
  UpsDiagSubSysFrameEntry  

upsDiagSubSysFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.2.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysFrameType 1.3.6.1.4.1.318.1.1.1.13.4.2.1.2
The type of Frame. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. frameTypeMain(3) indicates the frame type is the Main Frame. frameTypeXR(4) indicates the frame type is an XR Frame. frameTypeLXR(5) indicates the frame type is an LXR Frame.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), frameTypeMain(3), frameTypeXR(4), frameTypeLXR(5)  

upsDiagSubSysFrameFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.2.1.3
The firmware revision of the frame.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysFrameHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.2.1.4
The hardware revision of the frame.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysFrameSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.2.1.5
The serial number of the frame.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysFrameManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.2.1.6
The manufacture date of the frame.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysIntBypSwitchTableSize 1.3.6.1.4.1.318.1.1.1.13.4.3
The number of Internal Bypass switches attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysIntBypSwitchTable 1.3.6.1.4.1.318.1.1.1.13.4.4
Allows for diagnostics of the Internal Bypass Switch.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysIntBypSwitchEntry

upsDiagSubSysIntBypSwitchEntry 1.3.6.1.4.1.318.1.1.1.13.4.4.1
The diagnostics of the Internal Bypass Switch.
OBJECT-TYPE    
  UpsDiagSubSysIntBypSwitchEntry  

upsDiagSubSysIntBypSwitchFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.4.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysIntBypSwitchIndex 1.3.6.1.4.1.318.1.1.1.13.4.4.1.2
The Internal Bypass Switch index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysIntBypSwitchStatus 1.3.6.1.4.1.318.1.1.1.13.4.4.1.3
The Internal Bypass Switch status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysIntBypSwitchFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.4.1.4
The firmware revision of the Internal Bypass Switch.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysIntBypSwitchHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.4.1.5
The hardware revision of the Internal Bypass Switch.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysIntBypSwitchSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.4.1.6
The serial number of the Internal Bypass Switch.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysIntBypSwitchManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.4.1.7
The manufacture date of the Internal Bypass Switch.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysBattMonitorTableSize 1.3.6.1.4.1.318.1.1.1.13.4.5
The number of Battery Monitor Boards attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysBattMonitorTable 1.3.6.1.4.1.318.1.1.1.13.4.6
Allows for diagnostics of the Battery Monitor Board.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysBattMonitorEntry

upsDiagSubSysBattMonitorEntry 1.3.6.1.4.1.318.1.1.1.13.4.6.1
The diagnostics of the Battery Monitor Board.
OBJECT-TYPE    
  UpsDiagSubSysBattMonitorEntry  

upsDiagSubSysBattMonitorFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.6.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysBattMonitorIndex 1.3.6.1.4.1.318.1.1.1.13.4.6.1.2
The index of the Battery Monitor Board.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysBattMonitorStatus 1.3.6.1.4.1.318.1.1.1.13.4.6.1.3
The status of the Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysBattMonitorFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.6.1.4
The firmware revision of the Battery Monitor Board.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysBattMonitorHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.6.1.5
The hardware revision of the Battery Monitor Board.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysBattMonitorSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.6.1.6
The serial number of the Battery Monitor Board.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysBattMonitorManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.6.1.7
The date of the manufacture for the Battery Monitor Board.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysExternalSwitchGearTableSize 1.3.6.1.4.1.318.1.1.1.13.4.7
The number of External Switch Gears attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalSwitchGearTable 1.3.6.1.4.1.318.1.1.1.13.4.8
Allows for diagnostics of the individual External Switch Gear.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysExternalSwitchGearEntry

upsDiagSubSysExternalSwitchGearEntry 1.3.6.1.4.1.318.1.1.1.13.4.8.1
The diagnostics of an individual External Switch Gear.
OBJECT-TYPE    
  UpsDiagSubSysExternalSwitchGearEntry  

upsDiagSubSysExternalSwitchGearFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.8.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalSwitchGearIndex 1.3.6.1.4.1.318.1.1.1.13.4.8.1.2
The index of the External Switch Gear.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalSwitchGearStatus 1.3.6.1.4.1.318.1.1.1.13.4.8.1.3
The status of the External Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysExternalSwitchGearFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.8.1.4
The firmware revision of the External Switch Gear monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysExternalSwitchGearHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.8.1.5
The hardware revision of the External Switch Gear monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysExternalSwitchGearSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.8.1.6
The serial number of the External Switch Gear monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysExternalSwitchGearManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.8.1.7
The date of the manufacture for the External Switch Gear monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysDisplayInterfaceCardTableSize 1.3.6.1.4.1.318.1.1.1.13.4.9
The number of Display Interface Cards attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDisplayInterfaceCardTable 1.3.6.1.4.1.318.1.1.1.13.4.10
Allows for diagnostics of individual Display Interface Cards.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysDisplayInterfaceCardEntry

upsDiagSubSysDisplayInterfaceCardEntry 1.3.6.1.4.1.318.1.1.1.13.4.10.1
The diagnostics of a Display Interface Card.
OBJECT-TYPE    
  UpsDiagSubSysDisplayInterfaceCardEntry  

upsDiagSubSysDisplayInterfaceCardFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.10.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDisplayInterfaceCardIndex 1.3.6.1.4.1.318.1.1.1.13.4.10.1.2
The index of the Display Interface Card.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDisplayInterfaceCardStatus 1.3.6.1.4.1.318.1.1.1.13.4.10.1.3
The status of the Display Interface Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysDCCircuitBreakerTableSize 1.3.6.1.4.1.318.1.1.1.13.4.11
The number of DC Circuit Breakers attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDCCircuitBreakerTable 1.3.6.1.4.1.318.1.1.1.13.4.12
Allows for diagnostics of individual DC Circuit Breakers.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysDCCircuitBreakerEntry

upsDiagSubSysDCCircuitBreakerEntry 1.3.6.1.4.1.318.1.1.1.13.4.12.1
The diagnostics of a DC Circuit Breaker.
OBJECT-TYPE    
  UpsDiagSubSysDCCircuitBreakerEntry  

upsDiagSubSysDCCircuitBreakerFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.12.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDCCircuitBreakerIndex 1.3.6.1.4.1.318.1.1.1.13.4.12.1.2
The index of the DC Circuit Breaker.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysDCCircuitBreakerStatus 1.3.6.1.4.1.318.1.1.1.13.4.12.1.3
The status of the DC Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagSubSysSystemPowerSupplyTableSize 1.3.6.1.4.1.318.1.1.1.13.4.13
The number of System Power Supplies attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysSystemPowerSupplyTable 1.3.6.1.4.1.318.1.1.1.13.4.14
Allows for diagnostics of individual System Power Supplies.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysSystemPowerSupplyEntry

upsDiagSubSysSystemPowerSupplyEntry 1.3.6.1.4.1.318.1.1.1.13.4.14.1
The diagnostics of a System Power Supply.
OBJECT-TYPE    
  UpsDiagSubSysSystemPowerSupplyEntry  

upsDiagSubSysSystemPowerSupplyFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.14.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysSystemPowerSupplyIndex 1.3.6.1.4.1.318.1.1.1.13.4.14.1.2
The index of a System Power Supply.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysSystemPowerSupplyStatus 1.3.6.1.4.1.318.1.1.1.13.4.14.1.3
The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysSystemPowerSupplyFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.14.1.4
The firmware revision of the System Power Supply monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysSystemPowerSupplyHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.14.1.5
The hardware revision of the System Power Supply monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysSystemPowerSupplySerialNum 1.3.6.1.4.1.318.1.1.1.13.4.14.1.6
The serial number of the System Power Supply monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysSystemPowerSupplyManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.14.1.7
The date of the manufacture for the System Power Supply monitor card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysXRCommunicationCardTableSize 1.3.6.1.4.1.318.1.1.1.13.4.15
The number of XR Communication Cards attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysXRCommunicationCardTable 1.3.6.1.4.1.318.1.1.1.13.4.16
Allows for diagnostics of individual XR Communication Cards.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysXRCommunicationCardEntry

upsDiagSubSysXRCommunicationCardEntry 1.3.6.1.4.1.318.1.1.1.13.4.16.1
The diagnostics of an XR Communication Card.
OBJECT-TYPE    
  UpsDiagSubSysXRCommunicationCardEntry  

upsDiagSubSysXRCommunicationCardFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.16.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysXRCommunicationCardIndex 1.3.6.1.4.1.318.1.1.1.13.4.16.1.2
The index of an XR Communication Card.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysXRCommunicationCardStatus 1.3.6.1.4.1.318.1.1.1.13.4.16.1.3
The status of the XR Communication Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysXRCommunicationCardFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.16.1.4
The firmware revision of the XR Communication card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysXRCommunicationCardSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.16.1.5
The serial number of the XR Communication card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysExternalPowerFrameBoardTableSize 1.3.6.1.4.1.318.1.1.1.13.4.17
The number of External Power Frame Boards attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalPowerFrameBoardTable 1.3.6.1.4.1.318.1.1.1.13.4.18
Allows for diagnostics of individual External Power Frame Boards.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysExternalPowerFrameBoardEntry

upsDiagSubSysExternalPowerFrameBoardEntry 1.3.6.1.4.1.318.1.1.1.13.4.18.1
The diagnostics of an External Power Frame Board.
OBJECT-TYPE    
  UpsDiagSubSysExternalPowerFrameBoardEntry  

upsDiagSubSysExternalPowerFrameBoardFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.18.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalPowerFrameBoardIndex 1.3.6.1.4.1.318.1.1.1.13.4.18.1.2
The index of an External Power Frame Board.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysExternalPowerFrameBoardStatus 1.3.6.1.4.1.318.1.1.1.13.4.18.1.3
The status of the External Power Frame Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysChargerTableSize 1.3.6.1.4.1.318.1.1.1.13.4.19
The number of Chargers attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysChargerTable 1.3.6.1.4.1.318.1.1.1.13.4.20
Allows for diagnostics of individual chargers.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysChargerEntry

upsDiagSubSysChargerEntry 1.3.6.1.4.1.318.1.1.1.13.4.20.1
The diagnostics of a charger.
OBJECT-TYPE    
  UpsDiagSubSysChargerEntry  

upsDiagSubSysChargerFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.20.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysChargerIndex 1.3.6.1.4.1.318.1.1.1.13.4.20.1.2
The index of a charger.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysChargerStatus 1.3.6.1.4.1.318.1.1.1.13.4.20.1.3
The status of the Charger. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysInverterTableSize 1.3.6.1.4.1.318.1.1.1.13.4.21
The number of Inverters attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysInverterTable 1.3.6.1.4.1.318.1.1.1.13.4.22
Allows for diagnostics of individual Inverters.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysInverterEntry

upsDiagSubSysInverterEntry 1.3.6.1.4.1.318.1.1.1.13.4.22.1
The diagnostics of an Inverter.
OBJECT-TYPE    
  UpsDiagSubSysInverterEntry  

upsDiagSubSysInverterFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.22.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysInverterIndex 1.3.6.1.4.1.318.1.1.1.13.4.22.1.2
The index of an Inverter.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysInverterStatus 1.3.6.1.4.1.318.1.1.1.13.4.22.1.3
The status of the Inverter. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysInverterFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.22.1.4
The firmware revision of the Inverter monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysInverterHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.22.1.5
The hardware revision of the Inverter monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysInverterSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.22.1.6
The serial number of the Inverter monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysInverterManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.22.1.7
The date of manufacture for the Inverter monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysPowerFactorCorrectionTableSize 1.3.6.1.4.1.318.1.1.1.13.4.23
The number of Power Factor Correction devices attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysPowerFactorCorrectionTable 1.3.6.1.4.1.318.1.1.1.13.4.24
Allows for diagnostics of individual PowerFactorCorrections.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysPowerFactorCorrectionEntry

upsDiagSubSysPowerFactorCorrectionEntry 1.3.6.1.4.1.318.1.1.1.13.4.24.1
The diagnostics of a Power Factor Correction.
OBJECT-TYPE    
  UpsDiagSubSysPowerFactorCorrectionEntry  

upsDiagSubSysPowerFactorCorrectionFrameIndex 1.3.6.1.4.1.318.1.1.1.13.4.24.1.1
The frame index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysPowerFactorCorrectionIndex 1.3.6.1.4.1.318.1.1.1.13.4.24.1.2
The index of a Power Factor Correction.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysPowerFactorCorrectionStatus 1.3.6.1.4.1.318.1.1.1.13.4.24.1.3
The status of the Power Factor Correction. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)  

upsDiagSubSysPowerFactorCorrectionFirmwareRev 1.3.6.1.4.1.318.1.1.1.13.4.24.1.4
The firmware revision of the Power Factor Correction monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysPowerFactorCorrectionHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.24.1.5
The hardware revision of the Power Factor Correction monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysPowerFactorCorrectionSerialNum 1.3.6.1.4.1.318.1.1.1.13.4.24.1.6
The serial number of the Power Factor Correction monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysPowerFactorCorrectionManufactureDate 1.3.6.1.4.1.318.1.1.1.13.4.24.1.7
The date of the manufacture for the Power Factor Correction monitor.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardTableSize 1.3.6.1.4.1.318.1.1.1.13.4.25
The number of Network Communication Cards attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysNetworkComCardTable 1.3.6.1.4.1.318.1.1.1.13.4.26
Allows for getting diagnostics information of an individual Network Communication Card.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubSysNetworkComCardEntry

upsDiagSubSysNetworkComCardEntry 1.3.6.1.4.1.318.1.1.1.13.4.26.1
The diagnostics of a Network Communication Card.
OBJECT-TYPE    
  UpsDiagSubSysNetworkComCardEntry  

upsDiagSubSysNetworkComCardIndex 1.3.6.1.4.1.318.1.1.1.13.4.26.1.1
The UPS network and display interface communication card index entry.
OBJECT-TYPE    
  INTEGER  

upsDiagSubSysNetworkComCardModelNumber 1.3.6.1.4.1.318.1.1.1.13.4.26.1.2
A character string identifying the model number of the UPS network and display interface communication card. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardSerialNumber 1.3.6.1.4.1.318.1.1.1.13.4.26.1.3
A character string identifying the serial number of the UPS network and display interface communication card. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardDateOfManufacture 1.3.6.1.4.1.318.1.1.1.13.4.26.1.4
The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardHardwareRev 1.3.6.1.4.1.318.1.1.1.13.4.26.1.5
The hardware revision of the UPS network and display interface communication card. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardFirmwareAppRev 1.3.6.1.4.1.318.1.1.1.13.4.26.1.6
An ID string identifying the application firmware revision of the UPS network and display interface communication card.
OBJECT-TYPE    
  DisplayString  

upsDiagSubSysNetworkComCardFirmwareAppOSRev 1.3.6.1.4.1.318.1.1.1.13.4.26.1.7
An ID string identifying the application operating system firmware revision of the UPS network and display interface communication card.
OBJECT-TYPE    
  DisplayString  

upsDiagnosticExternalDevices 1.3.6.1.4.1.318.1.1.1.13.5
OBJECT IDENTIFIER    

upsDiagSwitchGear 1.3.6.1.4.1.318.1.1.1.13.5.1
OBJECT IDENTIFIER    

upsDiagSwitchGearStatus 1.3.6.1.4.1.318.1.1.1.13.5.1.1
The status of the Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6)  

upsDiagSwitchGearInputSwitchStatus 1.3.6.1.4.1.318.1.1.1.13.5.1.2
The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagSwitchGearOutputSwitchStatus 1.3.6.1.4.1.318.1.1.1.13.5.1.3
The status of the Switch Gear Output Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagSwitchGearBypassSwitchStatus 1.3.6.1.4.1.318.1.1.1.13.5.1.4
The status of the Switch Gear Bypass Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagSwitchGearBypassInputSwitchStatus 1.3.6.1.4.1.318.1.1.1.13.5.1.5
The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagSwitchGearBreakerTableSize 1.3.6.1.4.1.318.1.1.1.13.5.1.6
The number of switchgear breakers attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSwitchGearBreakerTable 1.3.6.1.4.1.318.1.1.1.13.5.1.7
Switchgear breaker table.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSwitchGearBreakerEntry

upsDiagSwitchGearBreakerEntry 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1
A list of switchgear breakers.
OBJECT-TYPE    
  UpsDiagSwitchGearBreakerEntry  

switchgearBreakerIndex 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.1
The index of the switchgear breaker.
OBJECT-TYPE    
  INTEGER  

switchgearBreakerPresent 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.2
Indicates if the switchgear breaker is present. notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

switchgearBreakerName 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.3
The name of the switchgear breaker.
OBJECT-TYPE    
  DisplayString  

upsDiagSubFeedBreakerTableSize 1.3.6.1.4.1.318.1.1.1.13.5.1.8
The number of subfeed breakers attached to the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagSubFeedBreakerTable 1.3.6.1.4.1.318.1.1.1.13.5.1.9
Subfeed breaker table.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsDiagSubFeedBreakerEntry

upsDiagSubFeedBreakerEntry 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1
A list of subfeed breakers.
OBJECT-TYPE    
  UpsDiagSubFeedBreakerEntry  

subfeedBreakerIndex 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.1
The index of the subfeed breakers.
OBJECT-TYPE    
  INTEGER  

subfeedBreakerPresent 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.2
Indicates if the subfeed breaker is present. notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

subfeedBreakerRating 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.3
The current rating of the installed subfeed breaker.
OBJECT-TYPE    
  INTEGER  

subfeedBreakerUpperAcceptPowerWarning 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.4
The maximum acceptable load before warning is issued. Expressed as percent of the subfeed breaker rating.
OBJECT-TYPE    
  INTEGER 0..100  

subfeedBreakerUpperAcceptPowerCritical 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.5
The maximum load before a critical alarm occurs. Expressed as percent of the subfeed breaker rating.
OBJECT-TYPE    
  INTEGER 0..125  

upsDiagSwitchGearInstallationLoadPct 1.3.6.1.4.1.318.1.1.1.13.5.1.10
The actual output load expressed as a percentage of the rating of the UPS.
OBJECT-TYPE    
  INTEGER  

upsDiagMCCBBox 1.3.6.1.4.1.318.1.1.1.13.5.2
OBJECT IDENTIFIER    

upsDiagMCCBBoxStatus 1.3.6.1.4.1.318.1.1.1.13.5.2.1
The status of the MCCB Box (Molded Case Circuit Breaker Box) external device. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. opened(3) indicates the circuit is opened. closed(4) indicates the circuit is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsDiagTransformer 1.3.6.1.4.1.318.1.1.1.13.5.3
OBJECT IDENTIFIER    

upsDiagTransformerStatus 1.3.6.1.4.1.318.1.1.1.13.5.3.1
The status of the External Transformer. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition. opened(7) indicates the circuit is opened. closed(8) indicates the circuit is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6), opened(7), closed(8)  

upsDiagnosticComBus 1.3.6.1.4.1.318.1.1.1.13.6
OBJECT IDENTIFIER    

upsDiagComBusInternalMIMStatus 1.3.6.1.4.1.318.1.1.1.13.6.1
The status of the internal MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)  

upsDiagComBusInternalRIMStatus 1.3.6.1.4.1.318.1.1.1.13.6.2
The status of the internal RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)  

upsDiagComBusMIMtoRIMStatus 1.3.6.1.4.1.318.1.1.1.13.6.3
The status of the MIM to RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)  

upsDiagComBusExternalMIMStatus 1.3.6.1.4.1.318.1.1.1.13.6.4
The status of the external MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)  

upsDiagComBusExternalRIMStatus 1.3.6.1.4.1.318.1.1.1.13.6.5
The status of the external RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)  

upsParallelSystem 1.3.6.1.4.1.318.1.1.1.14
OBJECT IDENTIFIER    

upsParallelSysLocalAddress 1.3.6.1.4.1.318.1.1.1.14.1
Defines the UPS ID number in the parallel system.
OBJECT-TYPE    
  INTEGER  

upsParallelSysRemoteAddress 1.3.6.1.4.1.318.1.1.1.14.2
Defines the total number of UPSs in parallel.
OBJECT-TYPE    
  INTEGER  

upsParallelSysRedundancy 1.3.6.1.4.1.318.1.1.1.14.3
The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that there is one redundant unit. nplus2 (3) indicates that there are two redundant units. nplus3 (4) indicates that there are three redundant units. nplus4 (5) indicates that there are four redundant unit. nplus5 (6) indicates that there are five redundant units.
OBJECT-TYPE    
  INTEGER nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)  

upsParallelInputMaximumCurrent 1.3.6.1.4.1.318.1.1.1.14.4
Maximum input RMS current of the parallel system measured in Amperes.
OBJECT-TYPE    
  INTEGER  

upsParallelTotalOutputPower 1.3.6.1.4.1.318.1.1.1.14.5
The Total Ouptut power of UPS in KW when UPS are configured in parallel or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelTotalOutputApparentPower 1.3.6.1.4.1.318.1.1.1.14.6
The Total Ouptut Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputPhaseTable 1.3.6.1.4.1.318.1.1.1.14.7
A list of input table entries.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsParallelInputPhaseEntry

upsParallelInputPhaseEntry 1.3.6.1.4.1.318.1.1.1.14.7.1
An entry containing information applicable to a particular input phase.
OBJECT-TYPE    
  UpsParallelInputPhaseEntry  

upsParallelInputPhaseTableIndex 1.3.6.1.4.1.318.1.1.1.14.7.1.1
The parallel unit identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelInputPhaseIndex 1.3.6.1.4.1.318.1.1.1.14.7.1.2
The input phase identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelInputCurrent 1.3.6.1.4.1.318.1.1.1.14.7.1.3
The input current in amperes, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputActivePower 1.3.6.1.4.1.318.1.1.1.14.7.1.4
The input power in kW, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputApparentPower 1.3.6.1.4.1.318.1.1.1.14.7.1.5
The input apparent power in kVA, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputVoltage 1.3.6.1.4.1.318.1.1.1.14.7.1.6
The input voltage of UPS in volts, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputMaxVoltage 1.3.6.1.4.1.318.1.1.1.14.7.1.7
The peak input voltage in VAC measured since the last reset, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputMaxCurrent 1.3.6.1.4.1.318.1.1.1.14.7.1.8
The peak input current in amperes measured since last reset, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelInputTotalActivePower 1.3.6.1.4.1.318.1.1.1.14.7.1.9
Total active input power of the parallel system in kW.
OBJECT-TYPE    
  INTEGER  

upsParallelInputTotalApparentPower 1.3.6.1.4.1.318.1.1.1.14.7.1.10
Total apparent input power of the parallel system in kVA.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputPhaseTable 1.3.6.1.4.1.318.1.1.1.14.8
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsParallelOutputPhaseEntry

upsParallelOutputPhaseEntry 1.3.6.1.4.1.318.1.1.1.14.8.1
An entry containing information applicable to a particular output phase.
OBJECT-TYPE    
  UpsParallelOutputPhaseEntry  

upsParallelOutputPhaseTableIndex 1.3.6.1.4.1.318.1.1.1.14.8.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputPhaseIndex 1.3.6.1.4.1.318.1.1.1.14.8.1.2
The output phase identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputCurrent 1.3.6.1.4.1.318.1.1.1.14.8.1.3
The output current in amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputLoad 1.3.6.1.4.1.318.1.1.1.14.8.1.4
The output load in VA, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputPercentLoad 1.3.6.1.4.1.318.1.1.1.14.8.1.5
The percentage of the UPS load capacity in VA at present redundancy being used on this output phase, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputPower 1.3.6.1.4.1.318.1.1.1.14.8.1.6
The output power in Watts, or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputApparentPowerTable 1.3.6.1.4.1.318.1.1.1.14.9
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsParallelOutputApparentPowerEntry

upsParallelOutputApparentPowerEntry 1.3.6.1.4.1.318.1.1.1.14.9.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  UpsParallelOutputApparentPowerEntry  

upsParallelOutputApparentPowerTableIndex 1.3.6.1.4.1.318.1.1.1.14.9.1.1
The UPS parallel output identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputApparentPower 1.3.6.1.4.1.318.1.1.1.14.9.1.2
The apparent power of each of UPS in kVA when UPS are configured in parallel.
OBJECT-TYPE    
  INTEGER  

upsParallelDiagSubSysBreakerTable 1.3.6.1.4.1.318.1.1.1.14.10
Allows for diagnostics of parallel Circuit Breakers.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsParallelDiagSubSysBreakerEntry

upsParallelDiagSubSysBreakerEntry 1.3.6.1.4.1.318.1.1.1.14.10.1
The diagnostics of Circuit Breaker.
OBJECT-TYPE    
  UpsParallelDiagSubSysBreakerEntry  

upsParallelDiagSubSysBreakerFrameIndex 1.3.6.1.4.1.318.1.1.1.14.10.1.1
The Parallel UPS index entry.
OBJECT-TYPE    
  INTEGER  

upsParallelDiagSubSysBreakerIndex 1.3.6.1.4.1.318.1.1.1.14.10.1.2
The index of the Circuit Breaker.
OBJECT-TYPE    
  INTEGER  

upsParallelDiagSubSysBreakerStatus 1.3.6.1.4.1.318.1.1.1.14.10.1.3
The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
OBJECT-TYPE    
  INTEGER unknown(1), notInstalled(2), opened(3), closed(4)  

upsParallelDiagSubSysBreakerName 1.3.6.1.4.1.318.1.1.1.14.10.1.4
The name of Circuit Breaker.
OBJECT-TYPE    
  DisplayString  

upsParallelOutputTotalPercentLoad 1.3.6.1.4.1.318.1.1.1.14.11
The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputActivePowerTable 1.3.6.1.4.1.318.1.1.1.14.12
A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsParallelOutputActivePowerEntry

upsParallelOutputActivePowerEntry 1.3.6.1.4.1.318.1.1.1.14.12.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  UpsParallelOutputActivePowerEntry  

upsParallelOutputActivePowerTableIndex 1.3.6.1.4.1.318.1.1.1.14.12.1.1
The UPS parallel output identifier.
OBJECT-TYPE    
  INTEGER  

upsParallelOutputActivePower 1.3.6.1.4.1.318.1.1.1.14.12.1.2
The active power of each UPS in kW when UPSs are configured in parallel.
OBJECT-TYPE    
  INTEGER  

upsParallelSysSwitchGearInstallationLoadPct 1.3.6.1.4.1.318.1.1.1.14.13
The actual output load expressed as a percentage of the rating of the Parallel UPS system.
OBJECT-TYPE    
  INTEGER  

upsParallelSysRedundancyStatus 1.3.6.1.4.1.318.1.1.1.14.14
Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redundant unit. nplus2 (3) two redundant units. nplus3 (4) three redundant units. nplus4 (5) four redundant units. nplus5 (6) five redundant units.
OBJECT-TYPE    
  INTEGER nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)  

upsParallelSysName 1.3.6.1.4.1.318.1.1.1.14.15
An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID.
OBJECT-TYPE    
  DisplayString  

upsPhysicalLayout 1.3.6.1.4.1.318.1.1.1.15
OBJECT IDENTIFIER    

upsIOFrameLayoutPositionID 1.3.6.1.4.1.318.1.1.1.15.1
Defines the position ID of UPS frame.
OBJECT-TYPE    
  INTEGER  

upsBottomFeedFrameLayoutPositionID 1.3.6.1.4.1.318.1.1.1.15.2
Defines the position ID of bottom feed frame.
OBJECT-TYPE    
  INTEGER  

upsSwitchGearLayoutPositionID 1.3.6.1.4.1.318.1.1.1.15.3
Defines the position ID of switchgear.
OBJECT-TYPE    
  INTEGER  

upsBatteryFrameLayoutTableSize 1.3.6.1.4.1.318.1.1.1.15.4
The number of battery frames.
OBJECT-TYPE    
  INTEGER  

upsBatteryFrameLayoutTable 1.3.6.1.4.1.318.1.1.1.15.5
Battery frame layout position ID table.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsBatteryFrameLayoutEntry

upsBatteryFrameLayoutEntry 1.3.6.1.4.1.318.1.1.1.15.5.1
A list of layout position IDs of battery frames.
OBJECT-TYPE    
  UpsBatteryFrameLayoutEntry  

batteryFrameIndex 1.3.6.1.4.1.318.1.1.1.15.5.1.1
The index of the battery frame.
OBJECT-TYPE    
  INTEGER  

batteryFramePositionID 1.3.6.1.4.1.318.1.1.1.15.5.1.2
Defines the position ID of each of the battery frames in the row.
OBJECT-TYPE    
  INTEGER  

upsSideCarFrameLayoutTableSize 1.3.6.1.4.1.318.1.1.1.15.6
The number of sidecar frames.
OBJECT-TYPE    
  INTEGER  

upsSideCarFrameLayoutTable 1.3.6.1.4.1.318.1.1.1.15.7
Sidecar frame layout position ID table.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsSideCarFrameLayoutEntry

upsSideCarFrameLayoutEntry 1.3.6.1.4.1.318.1.1.1.15.7.1
A list of sidecar frame layout position IDs.
OBJECT-TYPE    
  UpsSideCarFrameLayoutEntry  

sideCarFrameIndex 1.3.6.1.4.1.318.1.1.1.15.7.1.1
The index of the sidecar frame.
OBJECT-TYPE    
  INTEGER  

sideCarFramePositionID 1.3.6.1.4.1.318.1.1.1.15.7.1.2
Defines the position ID of each of the sidecar frames in the row.
OBJECT-TYPE    
  INTEGER  

upsPowerFrameLayoutTableSize 1.3.6.1.4.1.318.1.1.1.15.8
The number of power frames.
OBJECT-TYPE    
  INTEGER  

upsPowerFrameLayoutTable 1.3.6.1.4.1.318.1.1.1.15.9
Power frame layout position ID table.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsPowerFrameLayoutEntry

upsPowerFrameLayoutEntry 1.3.6.1.4.1.318.1.1.1.15.9.1
A list of power frame layout position IDs.
OBJECT-TYPE    
  UpsPowerFrameLayoutEntry  

powerFrameIndex 1.3.6.1.4.1.318.1.1.1.15.9.1.1
The index of the power frame.
OBJECT-TYPE    
  INTEGER  

powerFramePositionID 1.3.6.1.4.1.318.1.1.1.15.9.1.2
Defines the position ID of each of the power frames in the row.
OBJECT-TYPE    
  INTEGER  

upsIntegratedATS 1.3.6.1.4.1.318.1.1.1.16
OBJECT IDENTIFIER    

upsIntegratedATSSelectedSource 1.3.6.1.4.1.318.1.1.1.16.1
The source which is currently selected by the ATS to supply the UPS.
OBJECT-TYPE    
  INTEGER noSourceSelected(1), unknown(2), sourceA(3), sourceB(4)  

upsIntegratedATSPreferredSource 1.3.6.1.4.1.318.1.1.1.16.2
The preferred source of power when both sources are OK.
OBJECT-TYPE    
  INTEGER upsIntegratedATSNoSourcePreference(1), upsIntegratedATSPreferSourceA(2), upsIntegratedATSPreferSourceB(3)  

upsIntegratedATSUpsReturnStaggering 1.3.6.1.4.1.318.1.1.1.16.3
This is a delay factor applied to the retransfer of this UPS with integrated ATS. When multiple UPSs are in use from a single source, each UPS can have a unique delay value, which will reduce inrush by preventing all UPSs from transferring at the same time.
OBJECT-TYPE    
  INTEGER  

upsIntegratedATSSourceTableSize 1.3.6.1.4.1.318.1.1.1.16.4
The number of input sources for this integrated ATS.
OBJECT-TYPE    
  INTEGER  

upsIntegratedATSSourceTable 1.3.6.1.4.1.318.1.1.1.16.5
Allows for getting status and settings for the ATS input sources. The number of entries is contained in the upsIntegratedATSSourceTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsIntegratedATSSourceEntry

upsIntegratedATSSourceEntry 1.3.6.1.4.1.318.1.1.1.16.5.1
The input source status to get.
OBJECT-TYPE    
  UpsIntegratedATSSourceEntry  

upsIntegratedATSSourceIndex 1.3.6.1.4.1.318.1.1.1.16.5.1.1
The index to the input source entry.
OBJECT-TYPE    
  INTEGER  

upsIntegratedATSSourceName 1.3.6.1.4.1.318.1.1.1.16.5.1.2
The name of the input source. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

upsIntegratedATSSourceStatus 1.3.6.1.4.1.318.1.1.1.16.5.1.3
Getting this variable will return the input source status.
OBJECT-TYPE    
  INTEGER upsIntegratedATSSourceGood(1), upsIntegratedATSSourceBad(2), upsIntegratedATSSourceUnknown(3)  

upsIntegratedATSLineFailDelay 1.3.6.1.4.1.318.1.1.1.16.5.1.4
The delay between a selected input source becoming bad, and the ATS switching away from that source. This delay is used to make sure that the line has truly failed before the ATS will be switched. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

upsIntegratedATSLineStabilityDelay 1.3.6.1.4.1.318.1.1.1.16.5.1.5
The delay between an unselected input source becoming good, and the ATS switching to that source. This delay is used to make sure that the line has truly returned before the ATS will be switched. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

measureUps 1.3.6.1.4.1.318.1.1.2
OBJECT IDENTIFIER    

mUpsEnviron 1.3.6.1.4.1.318.1.1.2.1
OBJECT IDENTIFIER    

mUpsEnvironAmbientTemperature 1.3.6.1.4.1.318.1.1.2.1.1
The ambient temperature in Celsius for Probe 1.
OBJECT-TYPE    
  Gauge  

mUpsEnvironRelativeHumidity 1.3.6.1.4.1.318.1.1.2.1.2
The relative humidity as a percentage for Probe 1.
OBJECT-TYPE    
  Gauge  

mUpsEnvironAmbientTemperature2 1.3.6.1.4.1.318.1.1.2.1.3
The ambient temperature in Celsius for Probe 2.
OBJECT-TYPE    
  Gauge  

mUpsEnvironRelativeHumidity2 1.3.6.1.4.1.318.1.1.2.1.4
The relative humidity as a percentage for Probe 2.
OBJECT-TYPE    
  Gauge  

mUpsContact 1.3.6.1.4.1.318.1.1.2.2
OBJECT IDENTIFIER    

mUpsContactNumContacts 1.3.6.1.4.1.318.1.1.2.2.1
The number of contacts supported by the Measure-UPS.
OBJECT-TYPE    
  INTEGER  

mUpsContactTable 1.3.6.1.4.1.318.1.1.2.2.2
A list of contacts supported by the Measure-UPS.
OBJECT-TYPE    
  SEQUENCE OF  
    MUpsContactEntry

mUpsContactEntry 1.3.6.1.4.1.318.1.1.2.2.2.1
A contact entry containing information for a given contact.
OBJECT-TYPE    
  MUpsContactEntry  

contactNumber 1.3.6.1.4.1.318.1.1.2.2.2.1.1
An index identifying the contact on the Measure-UPS.
OBJECT-TYPE    
  INTEGER  

normalState 1.3.6.1.4.1.318.1.1.2.2.2.1.2
The normal operating position of the contact. If the normal operating position cannot be set then it is controlled via the dip switch on the Measure-UPS and is therefore read-only.
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3)  

description 1.3.6.1.4.1.318.1.1.2.2.2.1.3
The description of the purpose/use of the contact.
OBJECT-TYPE    
  DisplayString  

monitoringStatus 1.3.6.1.4.1.318.1.1.2.2.2.1.4
A flag indicating whether this contact is monitored, or not.
OBJECT-TYPE    
  INTEGER unknown(1), enabled(2), disabled(3)  

currentStatus 1.3.6.1.4.1.318.1.1.2.2.2.1.5
This value indicates the current state of the contact. If the contact is not in its normal state. This value is set to fault(2).
OBJECT-TYPE    
  INTEGER unknown(1), noFault(2), fault(3)  

miniSNMPadapter 1.3.6.1.4.1.318.1.1.3
OBJECT IDENTIFIER    

serialPort 1.3.6.1.4.1.318.1.1.3.1
OBJECT IDENTIFIER    

serialPort1 1.3.6.1.4.1.318.1.1.3.1.1
OBJECT IDENTIFIER    

serialPort2 1.3.6.1.4.1.318.1.1.3.1.2
OBJECT IDENTIFIER    

serialPort2Config 1.3.6.1.4.1.318.1.1.3.1.2.1
OBJECT IDENTIFIER    

serialPort2Mode 1.3.6.1.4.1.318.1.1.3.1.2.1.1
Setting this variable to passthrough will enable mini's port2 behave like a UPS port. Choosing localConsole will enable the port to be used as local console.
OBJECT-TYPE    
  INTEGER localConsole(1), passthrough(2)  

serialPort2Control 1.3.6.1.4.1.318.1.1.3.1.2.2
OBJECT IDENTIFIER    

setPulseOnTXD 1.3.6.1.4.1.318.1.1.3.1.2.2.1
Setting this variable to setPulseOnTXD(2) causes adapter to generate a PULSE on TXD pin of serial port 2. The duration in the prototype implementation will be 1 second. Setting this value to noSetPulseOnTXD(1) has no effect. The value noSetPulseOnTXD(1) will always be returned when the variable is read. Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD always low or high respectively.
OBJECT-TYPE    
  INTEGER noSetPulseOnTXD(1), setPulseOnTXD(2), setTXDLow(3), setTXDHigh(4)  

masterswitch 1.3.6.1.4.1.318.1.1.4
OBJECT IDENTIFIER    

sPDUIdent 1.3.6.1.4.1.318.1.1.4.1
OBJECT IDENTIFIER    

sPDUIdentHardwareRev 1.3.6.1.4.1.318.1.1.4.1.1
The hardware revision of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentFirmwareRev 1.3.6.1.4.1.318.1.1.4.1.2
An 8 byte ID string identifying the PDU firmware revision. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.4.1.3
The date when the PDU was manufactured in mm/dd/yy format. This value is set at the factory. The year 2000 will be represented by 00.
OBJECT-TYPE    
  DisplayString  

sPDUIdentModelNumber 1.3.6.1.4.1.318.1.1.4.1.4
A 10-character string identifying the model number of the PDU internal. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentSerialNumber 1.3.6.1.4.1.318.1.1.4.1.5
A 12-character string identifying the serial number of the PDU internal microprocessor. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUMasterControl 1.3.6.1.4.1.318.1.1.4.2
OBJECT IDENTIFIER    

sPDUMasterControlSwitch 1.3.6.1.4.1.318.1.1.4.2.1
Setting this OID to turnAllOnNow (1) will turn all outlets on immediately. Setting this OID to turnAllOnSequence (2) will turn all outlets on as defined by each outlet's sPDUOutletPowerOnTime OID value. Setting this OID to turnAllOff (3) will turn all outlets off immediately. Setting this OID to rebootAllNow (4) will reboot all outlets immediately. For MasterSwitch firmware version 1.X, setting this OID to rebootAllSequence (5) reboots all outlets, with power returned to the outlets in the sequence defined by each outlet's sPDUOutletPowerOnTime OID value. For MasterSwitch firmware version 2.X, setting this OID to rebootAllSequence (5) will cause a turnAllOffSequence to be performed. Once all outlets are off, the MasterSwitch will then delay the sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence. For MasterSwitch firmware version 2.X, setting this OID to turnAllOffSequence (7) will turn all outlets off as defined by each outlet's sPDUOutletPowerOffTime OID value. For MasterSwitch firmware version 1.X, setting this OID to turnAllOffSequence (7) will have no effect. Getting this OID will return the noCommand (6) value.
OBJECT-TYPE    
  INTEGER turnAllOnNow(1), turnAllOnSequence(2), turnAllOffNow(3), rebootAllNow(4), rebootAllSequence(5), noCommand(6), turnAllOffSequence(7)  

sPDUMasterState 1.3.6.1.4.1.318.1.1.4.2.2
Getting this OID will cause the status of all outlets to be returned. This OID is provided for informational purposes only. To change the outlet state, the user should use the sPDUOutletCtl OID in the sPDUOutletControlTable. The format of the data returned is a character string consisting of the word 'On' if the outlet is on or 'Off' if the outlet is off. At least one space will delimit each outlet entry in the string. If the outlet states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state.
OBJECT-TYPE    
  DisplayString  

sPDUMasterPending 1.3.6.1.4.1.318.1.1.4.2.3
Getting this OID will cause the command pending status of all outlets to be returned. The format of the data returned is a character string consisting of the word 'Yes' if a command is pending for the outlet or 'No' if there is no command pending for the outlet. At least one space will delimit each outlet entry in the string. If the pending states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state.
OBJECT-TYPE    
  DisplayString  

sPDUMasterConfig 1.3.6.1.4.1.318.1.1.4.3
OBJECT IDENTIFIER    

sPDUMasterConfigPowerOn 1.3.6.1.4.1.318.1.1.4.3.1
The amount of delay, in seconds, between when power is provided to the PDU and when the PDU provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigReboot 1.3.6.1.4.1.318.1.1.4.3.2
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is read-only for the MasterSwitch version 2.X and is the maximum sPDUOutletRebootDuration OID of the individual outlets.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigPDUName 1.3.6.1.4.1.318.1.1.4.3.3
The name of the PDU.
OBJECT-TYPE    
  DisplayString  

sPDUOutletControl 1.3.6.1.4.1.318.1.1.4.4
OBJECT IDENTIFIER    

sPDUOutletControlTableSize 1.3.6.1.4.1.318.1.1.4.4.1
The number of outlets for the PDU.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlTable 1.3.6.1.4.1.318.1.1.4.4.2
Allows for control of individual outlet switches. The number of entries is contained in the sPDUOutletControlTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletControlEntry

sPDUOutletControlEntry 1.3.6.1.4.1.318.1.1.4.4.2.1
The outlets to control.
OBJECT-TYPE    
  SPDUOutletControlEntry  

sPDUOutletControlIndex 1.3.6.1.4.1.318.1.1.4.4.2.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletPending 1.3.6.1.4.1.318.1.1.4.4.2.1.2
Reports whether the current outlet has a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition.
OBJECT-TYPE    
  INTEGER commandPending(1), noCommandPending(2), commandPendingUnknown(3)  

sPDUOutletCtl 1.3.6.1.4.1.318.1.1.4.4.2.1.3
Getting this variable will return the outlet state. If the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to outletOn (1) will turn the outlet on. Setting this variable to outletOff (2) will turn the outlet off. Setting this variable to outletReboot (3) will reboot the outlet. Setting this variable to outletOnWithDelay (5) will turn the outlet on after the sPDUOutletPowerOnTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletOffWithDelay (6) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletRebootWithDelay (7) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration OID time, then turn the outlet back on. This option is not valid for MasterSwitch firmware version 1.X.
OBJECT-TYPE    
  INTEGER outletOn(1), outletOff(2), outletReboot(3), outletUnknown(4), outletOnWithDelay(5), outletOffWithDelay(6), outletRebootWithDelay(7)  

sPDUOutletCtlName 1.3.6.1.4.1.318.1.1.4.4.2.1.4
The name of the outlet. Maximum size is 20 characters. This OID is provided for informational purposes only. This value is set by the sPDUOutletName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfig 1.3.6.1.4.1.318.1.1.4.5
OBJECT IDENTIFIER    

sPDUOutletConfigTableSize 1.3.6.1.4.1.318.1.1.4.5.1
The number of outlets for the PDU.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigTable 1.3.6.1.4.1.318.1.1.4.5.2
The list of outlets to configure. The number of entries is defined by the sPDUOutletConfigTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigEntry

sPDUOutletConfigEntry 1.3.6.1.4.1.318.1.1.4.5.2.1
The outlets to control.
OBJECT-TYPE    
  SPDUOutletConfigEntry  

sPDUOutletConfigIndex 1.3.6.1.4.1.318.1.1.4.5.2.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletPowerOnTime 1.3.6.1.4.1.318.1.1.4.5.2.1.2
The amount of time (in seconds) the outlet will delay powering on when the MasterSwitch is powered on. Allowed values are: -1 never power on automatically. 0 power on with the Master Switch. 15 power on 15 seconds after the MasterSwitch has power applied. 30 power on 30 seconds after the MasterSwitch has power applied. 45 power on 45 seconds after the MasterSwitch has power applied. 60 power on 60 seconds (1 minute) after the MasterSwitch has power applied. 120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied. 300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUOutletName 1.3.6.1.4.1.318.1.1.4.5.2.1.3
The name of the outlet. Maximum size is 20 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletPowerOffTime 1.3.6.1.4.1.318.1.1.4.5.2.1.4
The amount of time (in seconds) the outlet will delay powering off. Allowed values are: -1 never power off automatically. 0 power off with the MasterSwitch. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X.
OBJECT-TYPE    
  INTEGER  

sPDUOutletRebootDuration 1.3.6.1.4.1.318.1.1.4.5.2.1.5
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X.
OBJECT-TYPE    
  INTEGER  

masterswitchVM 1.3.6.1.4.1.318.1.1.5
OBJECT IDENTIFIER    

sPDUIdentVM 1.3.6.1.4.1.318.1.1.5.1
OBJECT IDENTIFIER    

sPDUIdentVMTableSize 1.3.6.1.4.1.318.1.1.5.1.1
The number of MasterSwitch VMs controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUIdentVMTable 1.3.6.1.4.1.318.1.1.5.1.2
Allows for query of the individual MasterSwitch VMs. The number of entries is contained in the sPDUIdentVMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUIdentVMEntry

sPDUIdentVMEntry 1.3.6.1.4.1.318.1.1.5.1.2.1
The MasterSwitch VMs to query.
OBJECT-TYPE    
  SPDUIdentVMEntry  

sPDUIdentVMIndex 1.3.6.1.4.1.318.1.1.5.1.2.1.1
The index to the MasterSwitch VM entry.
OBJECT-TYPE    
  INTEGER  

sPDUIdentNameVM 1.3.6.1.4.1.318.1.1.5.1.2.1.2
A 23-character string identifying the MasterSwitch VM.
OBJECT-TYPE    
  DisplayString  

sPDUIdentHardwareRevVM 1.3.6.1.4.1.318.1.1.5.1.2.1.3
The hardware version of the MasterSwitch VM. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentFirmwareRevVM 1.3.6.1.4.1.318.1.1.5.1.2.1.4
An 6-character ID string identifying the MasterSwitch VM firmware version. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentDateOfManufactureVM 1.3.6.1.4.1.318.1.1.5.1.2.1.5
The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentModelNumberVM 1.3.6.1.4.1.318.1.1.5.1.2.1.6
A 17-character string identifying the model number of the MasterSwitch VM. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentSerialNumberVM 1.3.6.1.4.1.318.1.1.5.1.2.1.7
A 17-character string identifying the serial number of the MasterSwitch VM. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUMasterControlVM 1.3.6.1.4.1.318.1.1.5.2
OBJECT IDENTIFIER    

sPDUMasterControlVMTableSize 1.3.6.1.4.1.318.1.1.5.2.1
The number of MasterSwitch VMs controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterControlVMTable 1.3.6.1.4.1.318.1.1.5.2.2
Allows for control of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterControlVMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterControlVMEntry

sPDUMasterControlVMEntry 1.3.6.1.4.1.318.1.1.5.2.2.1
The MasterSwitch VMs to control.
OBJECT-TYPE    
  SPDUMasterControlVMEntry  

sPDUMasterControlVMIndex 1.3.6.1.4.1.318.1.1.5.2.2.1.1
The index to the MasterSwitch VM entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterControlVMName 1.3.6.1.4.1.318.1.1.5.2.2.1.2
The name of the MasterSwitch VM. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigVMName OID.
OBJECT-TYPE    
  DisplayString  

sPDUMasterControlVMCommand 1.3.6.1.4.1.318.1.1.5.2.2.1.3
Setting this OID to immediateAllOnVM (2) will turn all outlets on immediately. Setting this OID to immediateAllOffVM (3) will turn all outlets off immediately. Setting this OID to immediateAllRebootVM (4) will reboot all outlets immediately. Setting this OID to delayedAllOnVM (5) will turn all outlets on as defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value. Setting this OID to delayedAllOffVM (6) will turn all outlets off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value. Setting this OID to sequencedAllRebootVM (7) will cause a immediateAllOffVM command to be performed. The MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM command to be performed. Each outlet will then wait its sPDUOutletConfigVMRebootDuration before returning power to the outlet. Setting this OID to delayedSequenceAllRebootVM (9) will cause a delayedAllOffVM command to be performed. Once all outlets are off, the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending commands on the MasterSwitch VM to be canceled. Setting this OID to audioAlarmMute (11) will temporarily silence the audible alarm for the duration of the current overload condition. The audible alarm will be activated on subsequent overload alarms. Getting this OID will return the noCommandAllVM (1) value.
OBJECT-TYPE    
  INTEGER noCommandAllVM(1), immediateAllOnVM(2), immediateAllOffVM(3), immediateAllRebootVM(4), delayedAllOnVM(5), delayedAllOffVM(6), sequencedAllRebootVM(7), delayedAllRebootVM(8), delayedSequenceAllRebootVM(9), cancelAllPendingCommandsVM(10), audioAlarmMute(11)  

sPDUMasterConfigVM 1.3.6.1.4.1.318.1.1.5.3
OBJECT IDENTIFIER    

sPDUMasterConfigVMTableSize 1.3.6.1.4.1.318.1.1.5.3.1
The number of MasterSwitch VMs configurable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigVMTable 1.3.6.1.4.1.318.1.1.5.3.2
Allows for configuration of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterConfigVMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterConfigVMEntry

sPDUMasterConfigVMEntry 1.3.6.1.4.1.318.1.1.5.3.2.1
The MasterSwitch VMs to configure.
OBJECT-TYPE    
  SPDUMasterConfigVMEntry  

sPDUMasterConfigVMIndex 1.3.6.1.4.1.318.1.1.5.3.2.1.1
The index to the MasterSwitch VM entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigVMName 1.3.6.1.4.1.318.1.1.5.3.2.1.2
The name of the MasterSwitch VM. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUMasterConfigVMColdstartDelay 1.3.6.1.4.1.318.1.1.5.3.2.1.3
The amount of delay, in seconds, between when power is provided to the MasterSwitch VM and when the MasterSwitch VM provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigVMAudioAlarmActivated 1.3.6.1.4.1.318.1.1.5.3.2.1.4
Setting this OID to audioAlarmActiveNever (1) will disable the audio alarm on the MasterSwitch VM. Setting this OID to audioAlarmActiveOnOverload (2) will activate the audio alarm on the MasterSwitch VM when an overload condition is present. Setting this OID to audioAlarmActiveOnOverloadImminent (3) will activate the audio alarm on the MasterSwitch VM when the load on the MasterSwitch VM has surpassed the sPDUMasterConfigVMHighLoadWarningThreshold OID value.
OBJECT-TYPE    
  INTEGER audioAlarmActiveNever(1), audioAlarmActiveOnOverload(2), audioAlarmActiveOnOverloadImminent(3)  

sPDUMasterConfigVMHighLoadWarningThreshold 1.3.6.1.4.1.318.1.1.5.3.2.1.5
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented as a percentage of full load.
OBJECT-TYPE    
  INTEGER 0..100  

sPDUMasterConfigVMLowLoadWarningThreshold 1.3.6.1.4.1.318.1.1.5.3.2.1.6
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented as a percentage of full load.
OBJECT-TYPE    
  INTEGER 0..100  

sPDUMasterConfigVMOverloadRestriction 1.3.6.1.4.1.318.1.1.5.3.2.1.7
This OID controls the behavior of the MasterSwitch VM when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets to turn on. Setting this OID to restrictOnWarning (2) will not allow outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets to turn on if the MasterSwitch Vm is in an overload condition.
OBJECT-TYPE    
  INTEGER alwaysAllowTurnON(1), restrictOnWarning(2), restrictOnOverload(3)  

sPDUMasterStatusVM 1.3.6.1.4.1.318.1.1.5.4
OBJECT IDENTIFIER    

sPDUMasterStatusVMTableSize 1.3.6.1.4.1.318.1.1.5.4.1
The number of MasterSwitch VMs at this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusVMTable 1.3.6.1.4.1.318.1.1.5.4.2
Allows for gathering of status from the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterStatusVMTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterStatusVMEntry

sPDUMasterStatusVMEntry 1.3.6.1.4.1.318.1.1.5.4.2.1
The MasterSwitch VMs to gather status from.
OBJECT-TYPE    
  SPDUMasterStatusVMEntry  

sPDUMasterStatusVMIndex 1.3.6.1.4.1.318.1.1.5.4.2.1.1
The index to the MasterSwitch VM entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusVMName 1.3.6.1.4.1.318.1.1.5.4.2.1.2
The name of the MasterSwitch VM. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUMasterStatusVMCommandPending 1.3.6.1.4.1.318.1.1.5.4.2.1.3
Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending commands.
OBJECT-TYPE    
  INTEGER commandPendingMasterTrueVM(1), commandPendingMasterFalseVM(2)  

sPDUMasterStatusVMOverloadCondition 1.3.6.1.4.1.318.1.1.5.4.2.1.4
Getting this OID will return overloadConditionTrueVM (1) if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overloadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated.
OBJECT-TYPE    
  INTEGER overloadConditionTrueVM(1), overloadConditionFalseVM(2)  

sPDUMasterStatusVMLowLoadCondition 1.3.6.1.4.1.318.1.1.5.4.2.1.5
Getting this OID will return lowLoadConditionTrueVM (1) if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated.
OBJECT-TYPE    
  INTEGER lowLoadConditionTrueVM(1), lowLoadConditionFalseVM(2)  

sPDUMasterStatusVMCurrentLoad 1.3.6.1.4.1.318.1.1.5.4.2.1.6
Getting this OID will return the total amount of power being consumed by the load. It is represented as a percentage of full load.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusVMMaxLoad 1.3.6.1.4.1.318.1.1.5.4.2.1.7
Getting this OID will return the total amount of power that this MasterSwitch VM can provide. It is represented in Amps.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusVMOutletCount 1.3.6.1.4.1.318.1.1.5.4.2.1.8
Getting this OID will return the number of controllable outlets for this MasterSwitch VM.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusVMRebootDuration 1.3.6.1.4.1.318.1.1.5.4.2.1.9
Getting this OID will return the largest sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlVM 1.3.6.1.4.1.318.1.1.5.5
OBJECT IDENTIFIER    

sPDUOutletControlVMTable 1.3.6.1.4.1.318.1.1.5.5.1
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletControlVMEntry

sPDUOutletControlVMEntry 1.3.6.1.4.1.318.1.1.5.5.1.1
The outlets to control.
OBJECT-TYPE    
  SPDUOutletControlVMEntry  

sPDUOutletControlVMIndex 1.3.6.1.4.1.318.1.1.5.5.1.1.1
The index to the MasterSwitch VM.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlVMName 1.3.6.1.4.1.318.1.1.5.5.1.1.2
The name of the MasterSwitch VM. Maximum size is 23 characters. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletControlVMOutletIndex 1.3.6.1.4.1.318.1.1.5.5.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlVMOutletName 1.3.6.1.4.1.318.1.1.5.5.1.1.4
The name of the outlet. Maximum size is 23 characters. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletControlVMOutletCommand 1.3.6.1.4.1.318.1.1.5.5.1.1.5
Getting this variable will return the outlet state. If the outlet is on, the immediateOnVM (1) value will be returned. If the outlet is off, the immediateOffVM (2) value will be returned. Setting this variable to immediateOnVM (1) will immediately turn the outlet on. Setting this variable to immediateOffVM (2) will immediately turn the outlet off. Setting this variable to immediateRebootVM (3) will immediately reboot the outlet. Setting this variable to delayedOnVM (4) will turn the outlet on after the sPDUOutletConfigVMPowerOnTime OID time has elapsed. Setting this variable to delayedOffVM (5) will turn the outlet off after the sPDUOutletConfigVMPowerOffTime OID time has elapsed. Setting this variable to delayedRebootVM (6) will cause the MasterSwitch VM to perform a delayedOffVM command, wait the sPDUOutletConfigVMRebootDuration OID time, and then perform the immediateOnVM command. Setting this variable to cancelPendingCommandVM (7) will cause any pending command to this outlet to be canceled.
OBJECT-TYPE    
  INTEGER immediateOnVM(1), immediateOffVM(2), immediateRebootVM(3), delayedOnVM(4), delayedOffVM(5), delayedRebootVM(6), cancelPendingCommandVM(7)  

sPDUOutletConfigVM 1.3.6.1.4.1.318.1.1.5.6
OBJECT IDENTIFIER    

sPDUOutletConfigVMTable 1.3.6.1.4.1.318.1.1.5.6.1
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigVMEntry

sPDUOutletConfigVMEntry 1.3.6.1.4.1.318.1.1.5.6.1.1
The outlets to configure.
OBJECT-TYPE    
  SPDUOutletConfigVMEntry  

sPDUOutletConfigVMIndex 1.3.6.1.4.1.318.1.1.5.6.1.1.1
The index to the MasterSwitch VM.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigVMName 1.3.6.1.4.1.318.1.1.5.6.1.1.2
The name of the MasterSwitch VM. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigVMOutletIndex 1.3.6.1.4.1.318.1.1.5.6.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigVMOutletName 1.3.6.1.4.1.318.1.1.5.6.1.1.4
The name of the outlet. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigVMPowerOnTime 1.3.6.1.4.1.318.1.1.5.6.1.1.5
The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 never power on. 0 power on immediately. 15 power on 15 seconds after being commanded. 30 power on 30 seconds after being commanded. 45 power on 45 seconds after being commanded. 60 power on 60 seconds (1 minute) after being commanded. 120 power on 120 seconds (2 minutes) after being commanded. 300 power on 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigVMPowerOffTime 1.3.6.1.4.1.318.1.1.5.6.1.1.6
The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 never power off automatically. 0 power off immediately. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigVMRebootDuration 1.3.6.1.4.1.318.1.1.5.6.1.1.7
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
OBJECT-TYPE    
  INTEGER  

sPDUOutletStatusVM 1.3.6.1.4.1.318.1.1.5.7
OBJECT IDENTIFIER    

sPDUOutletStatusVMTable 1.3.6.1.4.1.318.1.1.5.7.1
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletStatusVMEntry

sPDUOutletStatusVMEntry 1.3.6.1.4.1.318.1.1.5.7.1.1
The outlets to gather status from.
OBJECT-TYPE    
  SPDUOutletStatusVMEntry  

sPDUOutletStatusVMIndex 1.3.6.1.4.1.318.1.1.5.7.1.1.1
The index to the MasterSwitch VM.
OBJECT-TYPE    
  INTEGER  

sPDUOutletStatusVMName 1.3.6.1.4.1.318.1.1.5.7.1.1.2
The name of the MasterSwitch VM. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletStatusVMOutletIndex 1.3.6.1.4.1.318.1.1.5.7.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletStatusVMOutletName 1.3.6.1.4.1.318.1.1.5.7.1.1.4
The name of the outlet. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletStatusVMOutletState 1.3.6.1.4.1.318.1.1.5.7.1.1.5
Getting this variable will return the outlet state. If the outlet is on, the outletStatusOnVM (1) value will be returned. If the outlet is off, the outletStatusOffVM (2) value will be returned.
OBJECT-TYPE    
  INTEGER outletStatusVMOn(1), outletStatusVMOff(2)  

sPDUOutletStatusVMCommandPending 1.3.6.1.4.1.318.1.1.5.7.1.1.6
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusVMCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusVMNoCommandPending (2) will be returned.
OBJECT-TYPE    
  INTEGER outletStatusVMCommandPending(1), outletStatusVMNoCommandPending(2)  

masterswitchMSP 1.3.6.1.4.1.318.1.1.6
OBJECT IDENTIFIER    

sPDUIdentMSP 1.3.6.1.4.1.318.1.1.6.1
OBJECT IDENTIFIER    

sPDUIdentMSPTableSize 1.3.6.1.4.1.318.1.1.6.1.1
The number of MasterSwitch pluses controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUIdentMSPTable 1.3.6.1.4.1.318.1.1.6.1.2
Allows for query of the individual MasterSwitch pluses. The number of entries is contained in the sPDUIdentMSPTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUIdentMSPEntry

sPDUIdentMSPEntry 1.3.6.1.4.1.318.1.1.6.1.2.1
The MasterSwitch pluses to query.
OBJECT-TYPE    
  SPDUIdentMSPEntry  

sPDUIdentMSPIndex 1.3.6.1.4.1.318.1.1.6.1.2.1.1
The index to the MasterSwitch plus entry.
OBJECT-TYPE    
  INTEGER  

sPDUIdentNameMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUIdentHardwareRevMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.3
The hardware version of the MasterSwitch plus. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentFirmwareRevMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.4
An 6-character ID string identifying the MasterSwitch plus firmware version. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentDateOfManufactureMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.5
The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentModelNumberMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.6
A 17-character string identifying the model number of the MasterSwitch plus. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUIdentSerialNumberMSP 1.3.6.1.4.1.318.1.1.6.1.2.1.7
A 17-character string identifying the serial number of the MasterSwitch plus. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sPDUMasterControlMSP 1.3.6.1.4.1.318.1.1.6.2
OBJECT IDENTIFIER    

sPDUMasterControlMSPTableSize 1.3.6.1.4.1.318.1.1.6.2.1
The number of MasterSwitch pluses controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterControlMSPTable 1.3.6.1.4.1.318.1.1.6.2.2
Allows for control of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterControlMSPTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterControlMSPEntry

sPDUMasterControlMSPEntry 1.3.6.1.4.1.318.1.1.6.2.2.1
The MasterSwitch pluses to control.
OBJECT-TYPE    
  SPDUMasterControlMSPEntry  

sPDUMasterControlMSPIndex 1.3.6.1.4.1.318.1.1.6.2.2.1.1
The index to the MasterSwitch plus entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterControlMSPName 1.3.6.1.4.1.318.1.1.6.2.2.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUMasterControlMSPCommand 1.3.6.1.4.1.318.1.1.6.2.2.1.3
Setting this OID to immediateAllOnMSP (2) will turn all outlets on immediately. Setting this OID to sequencedAllOnMSP (3) will turn all outlets on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to immediateAllOffMSP (4) will turn all outlets off immediately. Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPRebootDuration OID time value. Setting this OID to immediateAllRebootMSP (6) will reboot all outlets immediately. Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each outlet will then turn on after the sum of its sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID values. Setting this OID to overrideAllBatCapThreshMSP (8) will cause the outlet to ignore the Battery Capacity Threshold and proceed turning on the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending commands on the MasterSwitch plus to be canceled. Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of the MasterSwitch plus to be restored to the factory defaults. Getting this OID will return the noCommandAllMSP (1) value.
OBJECT-TYPE    
  INTEGER noCommandAllMSP(1), immediateAllOnMSP(2), sequencedAllOnMSP(3), immediateAllOffMSP(4), gracefulAllRebootMSP(5), immediateAllRebootMSP(6), gracefulAllShutdownMSP(7), overrideAllBatCapThreshMSP(8), cancelAllPendingCommandsMSP(9), restoreFactoryDefaultsMSP(10)  

sPDUMasterConfigMSP 1.3.6.1.4.1.318.1.1.6.3
OBJECT IDENTIFIER    

sPDUMasterConfigMSPTableSize 1.3.6.1.4.1.318.1.1.6.3.1
The number of MasterSwitch pluses configurable by this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigMSPTable 1.3.6.1.4.1.318.1.1.6.3.2
Allows for configuration of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterConfigMSPTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterConfigMSPEntry

sPDUMasterConfigMSPEntry 1.3.6.1.4.1.318.1.1.6.3.2.1
The MasterSwitch pluses to configure.
OBJECT-TYPE    
  SPDUMasterConfigMSPEntry  

sPDUMasterConfigMSPIndex 1.3.6.1.4.1.318.1.1.6.3.2.1.1
The index to the MasterSwitch plus entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterConfigMSPName 1.3.6.1.4.1.318.1.1.6.3.2.1.2
The name of the MasterSwitch plus. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUMasterConfigMSPPowerOnTimeDelay 1.3.6.1.4.1.318.1.1.6.3.2.1.3
The amount of delay, in seconds, between when power is provided to the MasterSwitch plus and when the MasterSwitch plus provides basic master power to the outlets. Allowed values are: 0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs). 0 indicates to apply power immediately.
OBJECT-TYPE    
  INTEGER 0..9999  

sPDUMasterConfigMSPManualButton 1.3.6.1.4.1.318.1.1.6.3.2.1.4
Setting this OID to manualButtonDisabled (1) will disable the manual button on the MasterSwitch plus. Setting this OID to manualButtonEnabled (2) will enable the manual button on the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER manualButtonDisabled(1), manualButtonEnabled(2)  

sPDUMasterStatusMSP 1.3.6.1.4.1.318.1.1.6.4
OBJECT IDENTIFIER    

sPDUMasterStatusMSPTableSize 1.3.6.1.4.1.318.1.1.6.4.1
The number of MasterSwitch pluses at this IP address.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusMSPTable 1.3.6.1.4.1.318.1.1.6.4.2
Allows for gathering of status from the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterStatusMSPTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUMasterStatusMSPEntry

sPDUMasterStatusMSPEntry 1.3.6.1.4.1.318.1.1.6.4.2.1
The MasterSwitch pluses to gather status from.
OBJECT-TYPE    
  SPDUMasterStatusMSPEntry  

sPDUMasterStatusMSPIndex 1.3.6.1.4.1.318.1.1.6.4.2.1.1
The index to the MasterSwitch plus entry.
OBJECT-TYPE    
  INTEGER  

sPDUMasterStatusMSPName 1.3.6.1.4.1.318.1.1.6.4.2.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUMasterStatusMSPOutletCount 1.3.6.1.4.1.318.1.1.6.4.2.1.3
Getting this OID will return the number of controllable outlets for this MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlMSP 1.3.6.1.4.1.318.1.1.6.5
OBJECT IDENTIFIER    

sPDUOutletControlMSPTable 1.3.6.1.4.1.318.1.1.6.5.1
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletControlMSPEntry

sPDUOutletControlMSPEntry 1.3.6.1.4.1.318.1.1.6.5.1.1
The outlets to control.
OBJECT-TYPE    
  SPDUOutletControlMSPEntry  

sPDUOutletControlMSPIndex 1.3.6.1.4.1.318.1.1.6.5.1.1.1
The index to the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlMSPName 1.3.6.1.4.1.318.1.1.6.5.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletControlMSPOutletIndex 1.3.6.1.4.1.318.1.1.6.5.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletControlMSPOutletName 1.3.6.1.4.1.318.1.1.6.5.1.1.4
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletControlMSPOutletCommand 1.3.6.1.4.1.318.1.1.6.5.1.1.5
Getting this variable will return the outlet state. If the outlet is on, the immediateOnMSP (1) value will be returned. If the outlet is off, the immediateOffMSP (3) value will be returned. Setting this variable to immediateOnMSP (1) will immediately turn the outlet on. Setting this variable to delayedOnMSP (2) will turn the outlet on after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to immediateOffMSP (3) will immediately turn the outlet off. Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed. Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet. Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to ignore the Battery Capacity Threshold and proceed waiting on the sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on. Setting this variable to cancelPendingCommandMSP (8) will cause any pending command to this outlet to be canceled.
OBJECT-TYPE    
  INTEGER immediateOnMSP(1), delayedOnMSP(2), immediateOffMSP(3), gracefulRebootMSP(4), immediateRebootMSP(5), gracefulshutdownMSP(6), overrideBatCapThreshMSP(7), cancelPendingCommandMSP(8)  

sPDUOutletConfigMSP 1.3.6.1.4.1.318.1.1.6.6
OBJECT IDENTIFIER    

sPDUOutletConfigMSPall 1.3.6.1.4.1.318.1.1.6.6.1
OBJECT IDENTIFIER    

sPDUOutletConfigMSPallTable 1.3.6.1.4.1.318.1.1.6.6.1.1
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigMSPallEntry

sPDUOutletConfigMSPallEntry 1.3.6.1.4.1.318.1.1.6.6.1.1.1
The outlets to configure.
OBJECT-TYPE    
  SPDUOutletConfigMSPallEntry  

sPDUOutletConfigMSPallIndex 1.3.6.1.4.1.318.1.1.6.6.1.1.1.1
The index to the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPallName 1.3.6.1.4.1.318.1.1.6.6.1.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPallOutletIndex 1.3.6.1.4.1.318.1.1.6.6.1.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPallOutletName 1.3.6.1.4.1.318.1.1.6.6.1.1.1.4
The name of the outlet. Maximum size is 23 characters.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPallOutletCtrlMode 1.3.6.1.4.1.318.1.1.6.6.1.1.1.5
Setting this OID to modeGracefulShutdown (1) will put this outlet into the Graceful Shutdown control mode. Setting this OID to modeAnnunciator (2) will put this outlet into the Annunciator control mode.
OBJECT-TYPE    
  INTEGER modeGracefulShutdown(1), modeAnnunciator(2)  

sPDUOutletConfigMSPgs 1.3.6.1.4.1.318.1.1.6.6.2
OBJECT IDENTIFIER    

sPDUOutletConfigMSPgsTable 1.3.6.1.4.1.318.1.1.6.6.2.1
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigMSPgsEntry

sPDUOutletConfigMSPgsEntry 1.3.6.1.4.1.318.1.1.6.6.2.1.1
The outlets to configure.
OBJECT-TYPE    
  SPDUOutletConfigMSPgsEntry  

sPDUOutletConfigMSPgsIndex 1.3.6.1.4.1.318.1.1.6.6.2.1.1.1
The index to the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPgsName 1.3.6.1.4.1.318.1.1.6.6.2.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPgsOutletIndex 1.3.6.1.4.1.318.1.1.6.6.2.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPgsOutletName 1.3.6.1.4.1.318.1.1.6.6.2.1.1.4
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPgsOutletCtrlMode 1.3.6.1.4.1.318.1.1.6.6.2.1.1.5
The Control Mode of the outlet. This OID is provided for informational purposes only.
OBJECT-TYPE    
  INTEGER modeGracefulShutdown(1), modeAnnunciator(2)  

sPDUOutletConfigMSPgsDeviceConfirm 1.3.6.1.4.1.318.1.1.6.6.2.1.1.6
Setting this OID to deviceConfirmNo (1) cause the outlet to NOT wait for device confirmation while performing graceful operations. Setting this OID to deviceConfirmYes (2) cause the outlet to wait for device confirmation while performing graceful operations.
OBJECT-TYPE    
  INTEGER deviceConfirmNo(1), deviceConfirmYes(2)  

sPDUOutletConfigMSPgsLowBattWarning 1.3.6.1.4.1.318.1.1.6.6.2.1.1.7
The amount of delay, in 6 second intervals, between when the UPS goes on battery and the power down sequence for the outlet is initiated. Allowed values are: -2 - Never initiate the power down sequence on low battery warning. -1 - Initiate power down sequence based on remaining runtime. 1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs). 0 indicates to immediately initiate power down sequence on low battery warning.
OBJECT-TYPE    
  INTEGER -2..9999  

sPDUOutletConfigMSPgsLowBattMult 1.3.6.1.4.1.318.1.1.6.6.2.1.1.8
Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is set to -1 (On Runtime Remaining). Allows you to set the value to stagger the shutdown sequence of the outlets. 1 provides the longest delay (the outlet to shutoff first), and 7 would provide the shortest delay (the outlet to shut off last). Allowed values are: 1 - 7.
OBJECT-TYPE    
  INTEGER 1..7  

sPDUOutletConfigMSPgsRestartDelay 1.3.6.1.4.1.318.1.1.6.6.2.1.1.9
The amount of delay, in 6 minute intervals, between when the outlet is turned off and the outlet is turned back on when performing a Graceful Shutdown. Allowed values are: -1 - Never turn outlet back on after a Graceful shutdown. 0 - 9999 six minute intervals (0 - 999hrs, 54 mins).
OBJECT-TYPE    
  INTEGER -1..9999  

sPDUOutletConfigMSPgsPowerOnDelay 1.3.6.1.4.1.318.1.1.6.6.2.1.1.10
The amount of delay, in seconds, between the UPS entering normal (on-line) state and the outlet being powered on. Allowed values are: -1 - Remain Off when the UPS enters the on-line state. 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
OBJECT-TYPE    
  INTEGER -1..9999  

sPDUOutletConfigMSPgsPowerOffDelay 1.3.6.1.4.1.318.1.1.6.6.2.1.1.11
The amount of delay, in seconds, between when the server shuts down and the outlet is powered off. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
OBJECT-TYPE    
  INTEGER 0..9999  

sPDUOutletConfigMSPgsBattCapThresh 1.3.6.1.4.1.318.1.1.6.6.2.1.1.12
The minimum battery capacity, as a percent (0-100%), required of the UPS before an outlet will be allowed to power on. Allowed values are: 0 - 100 percent.
OBJECT-TYPE    
  INTEGER 0..100  

sPDUOutletConfigMSPgsRebootDuration 1.3.6.1.4.1.318.1.1.6.6.2.1.1.13
The amount of delay, in seconds, from outlet off until outlet on during a reboot. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
OBJECT-TYPE    
  INTEGER 0..9999  

sPDUOutletConfigMSPannun 1.3.6.1.4.1.318.1.1.6.6.3
OBJECT IDENTIFIER    

sPDUOutletConfigMSPannunTable 1.3.6.1.4.1.318.1.1.6.6.3.1
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigMSPannunEntry

sPDUOutletConfigMSPannunEntry 1.3.6.1.4.1.318.1.1.6.6.3.1.1
The outlets to configure.
OBJECT-TYPE    
  SPDUOutletConfigMSPannunEntry  

sPDUOutletConfigMSPannunIndex 1.3.6.1.4.1.318.1.1.6.6.3.1.1.1
The index to the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPannunName 1.3.6.1.4.1.318.1.1.6.6.3.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPannunOutletIndex 1.3.6.1.4.1.318.1.1.6.6.3.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPannunOutletName 1.3.6.1.4.1.318.1.1.6.6.3.1.1.4
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPannunOutletCtrlMode 1.3.6.1.4.1.318.1.1.6.6.3.1.1.5
The Control Mode of the outlet. This OID is provided for informational purposes only.
OBJECT-TYPE    
  INTEGER modeGracefulShutdown(1), modeAnnunciator(2)  

sPDUOutletConfigMSPannunInitialState 1.3.6.1.4.1.318.1.1.6.6.3.1.1.6
Setting this OID to initialStateOff (1) causes the outlet to default to off when in the non-alarmed condition. Setting this OID to initialStateOn (2) causes the outlet to default to on when in the non-alarmed condition.
OBJECT-TYPE    
  INTEGER initialStateOff(1), initialStateOn(2)  

sPDUOutletConfigMSPannunAlarmActionDly 1.3.6.1.4.1.318.1.1.6.6.3.1.1.7
The amount of time, in seconds, that an enabled Measure-UPS alarm must be asserted before an alarm condition is recognized. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
OBJECT-TYPE    
  INTEGER 0..9999  

sPDUOutletConfigMSPmups 1.3.6.1.4.1.318.1.1.6.6.4
OBJECT IDENTIFIER    

sPDUOutletConfigMSPmupsTable 1.3.6.1.4.1.318.1.1.6.6.4.1
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletConfigMSPmupsEntry

sPDUOutletConfigMSPmupsEntry 1.3.6.1.4.1.318.1.1.6.6.4.1.1
The outlets to configure.
OBJECT-TYPE    
  SPDUOutletConfigMSPmupsEntry  

sPDUOutletConfigMSPmupsIndex 1.3.6.1.4.1.318.1.1.6.6.4.1.1.1
The index to the MasterSwitch plus.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPmupsName 1.3.6.1.4.1.318.1.1.6.6.4.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPmupsOutletIndex 1.3.6.1.4.1.318.1.1.6.6.4.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletConfigMSPmupsOutletName 1.3.6.1.4.1.318.1.1.6.6.4.1.1.4
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletConfigMSPmupsZone1 1.3.6.1.4.1.318.1.1.6.6.4.1.1.5
Setting this OID to disableAlarm (1) disables the Zone 1 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 1 alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsZone2 1.3.6.1.4.1.318.1.1.6.6.4.1.1.6
Setting this OID to disableAlarm (1) disables the Zone 2 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 2 alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsZone3 1.3.6.1.4.1.318.1.1.6.6.4.1.1.7
Setting this OID to disableAlarm (1) disables the Zone 3 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 3 alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsZone4 1.3.6.1.4.1.318.1.1.6.6.4.1.1.8
Setting this OID to disableAlarm (1) disables the Zone 4 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 4 alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP1LowHum 1.3.6.1.4.1.318.1.1.6.6.4.1.1.9
Setting this OID to disableAlarm (1) disables the Probe 1 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low humidity alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP1HiHum 1.3.6.1.4.1.318.1.1.6.6.4.1.1.10
Setting this OID to disableAlarm (1) disables the Probe 1 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high humidity alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP1LowTemp 1.3.6.1.4.1.318.1.1.6.6.4.1.1.11
Setting this OID to disableAlarm (1) disables the Probe 1 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low temperature alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP1HiTemp 1.3.6.1.4.1.318.1.1.6.6.4.1.1.12
Setting this OID to disableAlarm (1) disables the Probe 1 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high temperature alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP2LowHum 1.3.6.1.4.1.318.1.1.6.6.4.1.1.13
Setting this OID to disableAlarm (1) disables the Probe 2 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low humidity alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP2HiHum 1.3.6.1.4.1.318.1.1.6.6.4.1.1.14
Setting this OID to disableAlarm (1) disables the Probe 2 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high humidity alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP2LowTemp 1.3.6.1.4.1.318.1.1.6.6.4.1.1.15
Setting this OID to disableAlarm (1) disables the Probe 2 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low temperature alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletConfigMSPmupsP2HiTemp 1.3.6.1.4.1.318.1.1.6.6.4.1.1.16
Setting this OID to disableAlarm (1) disables the Probe 2 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high temperature alarm for this outlet.
OBJECT-TYPE    
  INTEGER disableAlarm(1), enableAlarm(2)  

sPDUOutletStatusMSP 1.3.6.1.4.1.318.1.1.6.7
OBJECT IDENTIFIER    

sPDUOutletStatusMSPTable 1.3.6.1.4.1.318.1.1.6.7.1
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SPDUOutletStatusMSPEntry

sPDUOutletStatusMSPEntry 1.3.6.1.4.1.318.1.1.6.7.1.1
The outlets to gather status from.
OBJECT-TYPE    
  SPDUOutletStatusMSPEntry  

sPDUOutletStatusMSPIndex 1.3.6.1.4.1.318.1.1.6.7.1.1.1
The index to the MasterSwitch MSP.
OBJECT-TYPE    
  INTEGER  

sPDUOutletStatusMSPName 1.3.6.1.4.1.318.1.1.6.7.1.1.2
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
OBJECT-TYPE    
  DisplayString  

sPDUOutletStatusMSPOutletIndex 1.3.6.1.4.1.318.1.1.6.7.1.1.3
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sPDUOutletStatusMSPOutletName 1.3.6.1.4.1.318.1.1.6.7.1.1.4
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

sPDUOutletStatusMSPOutletState 1.3.6.1.4.1.318.1.1.6.7.1.1.5
Getting this variable will return the outlet state. If the outlet is on, the outletStatusMSPOn (1) value will be returned. If the outlet is off, the outletStatusMSPOff (2) value will be returned.
OBJECT-TYPE    
  INTEGER outletStatusMSPOn(1), outletStatusMSPOff(2)  

sPDUOutletStatusMSPCommandPending 1.3.6.1.4.1.318.1.1.6.7.1.1.6
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusMSPCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusMSPNoCommandPending (2) will be returned.
OBJECT-TYPE    
  INTEGER outletStatusMSPCommandPending(1), outletStatusMSPNoCommandPending(2)  

sPDUOutletStatusMSPOutletCtrlMode 1.3.6.1.4.1.318.1.1.6.7.1.1.7
The Control Mode of the outlet. This OID is provided for informational purposes only.
OBJECT-TYPE    
  INTEGER modeGracefulShutdown(1), modeAnnunciator(2)  

dcDM3 1.3.6.1.4.1.318.1.1.7
OBJECT IDENTIFIER    

dm3Ident 1.3.6.1.4.1.318.1.1.7.1
OBJECT IDENTIFIER    

dm3IdentSystem 1.3.6.1.4.1.318.1.1.7.1.1
OBJECT IDENTIFIER    

dm3IdentSysDescriptionTableSize 1.3.6.1.4.1.318.1.1.7.1.1.1
The number of DC description records.
OBJECT-TYPE    
  INTEGER  

dm3IdentSysDescriptionTable 1.3.6.1.4.1.318.1.1.7.1.1.2
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3IdentSysDescriptionTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3IdentSysDescriptionEntry

dm3IdentSysDescriptionEntry 1.3.6.1.4.1.318.1.1.7.1.1.2.1
The powerplant description record to reference.
OBJECT-TYPE    
  Dm3IdentSysDescriptionEntry  

dm3IdentSysDescriptionIndex 1.3.6.1.4.1.318.1.1.7.1.1.2.1.1
The index to the DC powerplant description record.
OBJECT-TYPE    
  INTEGER  

dm3IdentSysDescriptionText 1.3.6.1.4.1.318.1.1.7.1.1.2.1.2
A 16 character text field describing the DC power plant device. This field can be configured from the dm3ConfigSysDescriptionText OID.
OBJECT-TYPE    
  DisplayString  

dm3IdentSysModel 1.3.6.1.4.1.318.1.1.7.1.1.3
Model type of the DC power plant.
OBJECT-TYPE    
  INTEGER  

dm3IdentSysCntrlRev 1.3.6.1.4.1.318.1.1.7.1.1.4
Integer representation of the hardware revision of the Master Controller board.
OBJECT-TYPE    
  INTEGER  

dm3IdentSysFWVersion 1.3.6.1.4.1.318.1.1.7.1.1.5
Integer representation of the power plant Master Controller firmware revision.
OBJECT-TYPE    
  INTEGER  

dm3Config 1.3.6.1.4.1.318.1.1.7.2
OBJECT IDENTIFIER    

dm3ConfigSystem 1.3.6.1.4.1.318.1.1.7.2.1
OBJECT IDENTIFIER    

dm3ConfigSysDescriptionTableSize 1.3.6.1.4.1.318.1.1.7.2.1.1
The number of DC description records.
OBJECT-TYPE    
  INTEGER  

dm3ConfigSysDescriptionTable 1.3.6.1.4.1.318.1.1.7.2.1.2
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigSysDescriptionEntry

dm3ConfigSysDescriptionEntry 1.3.6.1.4.1.318.1.1.7.2.1.2.1
The powerplant description record to reference.
OBJECT-TYPE    
  Dm3ConfigSysDescriptionEntry  

dm3ConfigSysDescriptionIndex 1.3.6.1.4.1.318.1.1.7.2.1.2.1.1
The index to the DC powerplant description record.
OBJECT-TYPE    
  INTEGER  

dm3ConfigSysDescriptionText 1.3.6.1.4.1.318.1.1.7.2.1.2.1.2
16 character text field describing the DC power plant device.
OBJECT-TYPE    
  DisplayString  

dm3ConfigSysHighTempThresh 1.3.6.1.4.1.318.1.1.7.2.1.3
Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigSysHighTempAlarm 1.3.6.1.4.1.318.1.1.7.2.1.4
For the System High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigSysLowTempThresh 1.3.6.1.4.1.318.1.1.7.2.1.5
Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigSysLowTempAlarm 1.3.6.1.4.1.318.1.1.7.2.1.6
For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigSysHardwareTempAlarm 1.3.6.1.4.1.318.1.1.7.2.1.7
For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigSysRemoteAccess 1.3.6.1.4.1.318.1.1.7.2.1.8
This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Setting this OID to accessDisabled (2) will disable the ability to remotely configure the DC powerplant. Once remote access is disabled, it can only be restored from the front panel of the DC power plant.
OBJECT-TYPE    
  INTEGER accessEnabled(1), accessDisabled(2)  

dm3ConfigLVD 1.3.6.1.4.1.318.1.1.7.2.2
OBJECT IDENTIFIER    

dm3ConfigLVDTableSize 1.3.6.1.4.1.318.1.1.7.2.2.1
The number of DC powerplant LVDs controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3ConfigLVDTable 1.3.6.1.4.1.318.1.1.7.2.2.2
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3ConfigLVDTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigLVDEntry

dm3ConfigLVDEntry 1.3.6.1.4.1.318.1.1.7.2.2.2.1
The LVD to configure.
OBJECT-TYPE    
  Dm3ConfigLVDEntry  

dm3ConfigLVDIndex 1.3.6.1.4.1.318.1.1.7.2.2.2.1.1
The index to the DC powerplant LVD.
OBJECT-TYPE    
  INTEGER  

dm3ConfigLVDName 1.3.6.1.4.1.318.1.1.7.2.2.2.1.2
The name of the LVD. The maximum value is 16 characters.
OBJECT-TYPE    
  DisplayString  

dm3ConfigLVDEnable 1.3.6.1.4.1.318.1.1.7.2.2.2.1.3
This OID is used to control and indicate if the LVD is on or off. Setting this OID to enabledYes (1) will enable (turn on) the LVD. Setting this OID to enabledNo (2) will disable (turn off) the LVD.
OBJECT-TYPE    
  INTEGER enabledYes(1), enabledNo(2)  

dm3ConfigLVDTripThresh 1.3.6.1.4.1.318.1.1.7.2.2.2.1.4
LVD Trip threshold. If voltage exceeds threshold, the LVD will trip. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigLVDResetThresh 1.3.6.1.4.1.318.1.1.7.2.2.2.1.5
LVD Reset threshold. If voltage exceeds threshold, the LVD will reset. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigLVDOpenAlarm 1.3.6.1.4.1.318.1.1.7.2.2.2.1.6
For the LVD Open Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigLVDHWAlarm 1.3.6.1.4.1.318.1.1.7.2.2.2.1.7
For the LVD Hardware Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattery 1.3.6.1.4.1.318.1.1.7.2.3
OBJECT IDENTIFIER    

dm3ConfigBattFloatVolt 1.3.6.1.4.1.318.1.1.7.2.3.1
Battery Float Voltage. This setting controls the power plant voltage. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattMaxRecharge 1.3.6.1.4.1.318.1.1.7.2.3.2
Battery Maximum Recharge Rate. This setting controls the battery max recharge rate. The value is based on C/20 for 240 AHr battery string. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattDischargeThresh 1.3.6.1.4.1.318.1.1.7.2.3.3
Battery discharge threshold. If battery output current exceeds threshold a battery discharge alarm will occur. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattDischargeAlarm 1.3.6.1.4.1.318.1.1.7.2.3.4
For the Battery Discharge Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattHighVoltThresh 1.3.6.1.4.1.318.1.1.7.2.3.5
Battery high voltage threshold. If system battery voltage exceeds threshold a battery high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattHighVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.3.6
For the Battery High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattLowVoltThresh 1.3.6.1.4.1.318.1.1.7.2.3.7
Battery low voltage threshold. If system battery voltage is under threshold a battery low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattLowVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.3.8
For the Battery Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattHighTempThresh 1.3.6.1.4.1.318.1.1.7.2.3.9
Battery high temperature threshold. If system battery temperature exceeds threshold a battery high temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattHighTempAlarm 1.3.6.1.4.1.318.1.1.7.2.3.10
For the Battery High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattLowTempThresh 1.3.6.1.4.1.318.1.1.7.2.3.11
Battery low temperature threshold. If system battery temperature is under threshold a battery low temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattLowTempAlarm 1.3.6.1.4.1.318.1.1.7.2.3.12
For the Battery Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattAmpHour 1.3.6.1.4.1.318.1.1.7.2.3.13
Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigCompMethod 1.3.6.1.4.1.318.1.1.7.2.3.14
This OID is used to configure and get the state of the battery temperature compensation. Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation. Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation.
OBJECT-TYPE    
  INTEGER tempcompOn(1), tempcompOff(2)  

dm3ConfigCompTempCoeff 1.3.6.1.4.1.318.1.1.7.2.3.15
Compensation Temperature Coefficient. (uV/degC/cell). Units are presented in microvolts. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigHighKneeTemp 1.3.6.1.4.1.318.1.1.7.2.3.16
High Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigLowKneeTemp 1.3.6.1.4.1.318.1.1.7.2.3.17
Low Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBattHwCurrentAlarm 1.3.6.1.4.1.318.1.1.7.2.3.18
For the Battery Current Hardware Alarm (indicating current is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigBattHwTempAlarm 1.3.6.1.4.1.318.1.1.7.2.3.19
For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigPowerModules 1.3.6.1.4.1.318.1.1.7.2.4
OBJECT IDENTIFIER    

dm3ConfigRectifier 1.3.6.1.4.1.318.1.1.7.2.4.1
OBJECT IDENTIFIER    

dm3ConfigRectThresh 1.3.6.1.4.1.318.1.1.7.2.4.1.1
OBJECT IDENTIFIER    

dm3ConfigRectHighVoltThresh 1.3.6.1.4.1.318.1.1.7.2.4.1.1.1
Rectifier high voltage threshold. If rectifier voltage exceeds threshold a rectifier high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigRectLowVoltThresh 1.3.6.1.4.1.318.1.1.7.2.4.1.1.2
Rectifier low voltage threshold. If rectifier voltage is under threshold a rectifier low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigRectFailSafe 1.3.6.1.4.1.318.1.1.7.2.4.1.1.3
Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigRectFailComm 1.3.6.1.4.1.318.1.1.7.2.4.1.1.4
Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller at which the rectifier will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigRectAlarms 1.3.6.1.4.1.318.1.1.7.2.4.1.2
OBJECT IDENTIFIER    

dm3ConfigRectHighVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.1
For the Rectifier High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRectLowVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.2
For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRectConfigAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.3
This alarm is activated when a new rectifier is detected; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRect1ofNAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.4
This setting indicates the action if ONE rectifier of a N+1 system has failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRect2ofNAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.5
This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRectDiagAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.6
For the Rectifier Controller Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRectImbalanceAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.7
For the Rectifier Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigRectCurrLimitAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.8
For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRectStandbyAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.9
For the Rectifier Standby Alarm (indicating output DC has been turned off); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRectFanFailAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.10
For the Rectifier Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRectFailAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.11
For the Rectifier Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRectHwVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.1.2.12
For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConverter 1.3.6.1.4.1.318.1.1.7.2.4.2
OBJECT IDENTIFIER    

dm3ConfigConvThresh 1.3.6.1.4.1.318.1.1.7.2.4.2.1
OBJECT IDENTIFIER    

dm3ConfigConvHighVoltThresh 1.3.6.1.4.1.318.1.1.7.2.4.2.1.1
Converter high voltage threshold. If converter voltage exceeds threshold a converter high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvLowVoltThresh 1.3.6.1.4.1.318.1.1.7.2.4.2.1.2
Converter low voltage threshold. If converter voltage exceeds threshold a converter low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvFailSafe 1.3.6.1.4.1.318.1.1.7.2.4.2.1.3
Converter Fail Safe point. This OID represents the value sent to converter controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvSetPoint 1.3.6.1.4.1.318.1.1.7.2.4.2.1.4
Converter Set point. This OID represents the initial set point used in the voltage control loop. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvFailMax 1.3.6.1.4.1.318.1.1.7.2.4.2.1.5
Converter Fail Maximum limit. This OID represents the value sent to the converter controllers to define the maximum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvFailMin 1.3.6.1.4.1.318.1.1.7.2.4.2.1.6
Converter Fail Minimum limit. This OID represents the value sent to the converter controllers to define the minimum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvFailComm 1.3.6.1.4.1.318.1.1.7.2.4.2.1.7
Converter Communication Fail timeout. This OID represents the time interval in which there is no communication between the converter and the master controller at which the converter will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigConvAlarms 1.3.6.1.4.1.318.1.1.7.2.4.2.2
OBJECT IDENTIFIER    

dm3ConfigConvHighVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.1
For the Converter High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConvLowVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.2
For the Converter Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConvConfigAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.3
For the Converter Configuration Alarm (indicating a new converter has been detected); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConv1ofNAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.4
For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConv2ofNAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.5
For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigConvDiagAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.6
For the Converter Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvImbalanceAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.7
For the Converter Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvCurrLimitAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.8
For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvStandbyAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.9
For the Converter Standby Alarm (indicating the converter is in the Standby state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvFanFailAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.10
For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvFailAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.11
For the Converter Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigConvHwVoltAlarm 1.3.6.1.4.1.318.1.1.7.2.4.2.2.12
For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)  

dm3ConfigRelays 1.3.6.1.4.1.318.1.1.7.2.5
OBJECT IDENTIFIER    

dm3ConfigOutputRelays 1.3.6.1.4.1.318.1.1.7.2.5.1
OBJECT IDENTIFIER    

dm3ConfigOutRlyTableSize 1.3.6.1.4.1.318.1.1.7.2.5.1.1
The number of DC powerplant Output Relays controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3ConfigOutRlyTable 1.3.6.1.4.1.318.1.1.7.2.5.1.2
Allows for accessing settings of the Output Relays. The number of entries is contained in the dm3ConfigOutRlyTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigOutRlyEntry

dm3ConfigOutRlyEntry 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1
The output relay to configure.
OBJECT-TYPE    
  Dm3ConfigOutRlyEntry  

dm3ConfigOutRlyIndex 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.1
The index to the DC powerplant output relay.
OBJECT-TYPE    
  INTEGER  

dm3ConfigOutRlyName 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.2
The name of the output relay. The maximum value is 16 characters.
OBJECT-TYPE    
  DisplayString  

dm3ConfigOutRlyDelay 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.3
Output Relay Delay. This OID represents the time delay from the initiation of an output relay action to when the output relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Delay for Major and Minor alarms is not configurable and is always set to 0. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigOutRlyAlarm 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.4
Output Relay Alarm. This setting indicates what action to perform in the event of an output relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Relay Alarm for Major and Minor alarms is not configurable and is always set to alarmMajor and alarmMinor respectively.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigInputRelays 1.3.6.1.4.1.318.1.1.7.2.5.2
OBJECT IDENTIFIER    

dm3ConfigInRlyTableSize 1.3.6.1.4.1.318.1.1.7.2.5.2.1
The number of DC powerplant Input Relays controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3ConfigInRlyTable 1.3.6.1.4.1.318.1.1.7.2.5.2.2
Allows for accessing settings of the Input Relays. The number of entries is contained in the dm3ConfigInRlyTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigInRlyEntry

dm3ConfigInRlyEntry 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1
The input relay to configure.
OBJECT-TYPE    
  Dm3ConfigInRlyEntry  

dm3ConfigInRlyIndex 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.1
The index to the DC powerplant input relay.
OBJECT-TYPE    
  INTEGER  

dm3ConfigInRlyName 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.2
The name of the input relay. The maximum value is 16 characters.
OBJECT-TYPE    
  DisplayString  

dm3ConfigInRlyDelay 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.3
Input Relay Delay. This OID represents the time delay from the initiation of an input relay action to when the input relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
OBJECT-TYPE    
  INTEGER  

dm3ConfigInRlyAlarm 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.4
Input Relay Alarm. This setting indicates what action to perform in the event of an input relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigDistribution 1.3.6.1.4.1.318.1.1.7.2.6
OBJECT IDENTIFIER    

dm3ConfigBreakers 1.3.6.1.4.1.318.1.1.7.2.6.1
OBJECT IDENTIFIER    

dm3ConfigBreakersTableSize 1.3.6.1.4.1.318.1.1.7.2.6.1.1
The number of DC powerplant circuit breakers controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBreakersTable 1.3.6.1.4.1.318.1.1.7.2.6.1.2
Allows for accessing settings of the circuit breakers. The number of entries is contained in the dm3ConfigBreakersTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigBreakersEntry

dm3ConfigBreakersEntry 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1
The circuit breaker to configure.
OBJECT-TYPE    
  Dm3ConfigBreakersEntry  

dm3ConfigBreakersIndex 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.1
The index to the DC powerplant circuit breaker.
OBJECT-TYPE    
  INTEGER  

dm3ConfigBreakersName 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.2
The name of the circuit breaker. The maximum value is 16 characters.
OBJECT-TYPE    
  DisplayString  

dm3ConfigBreakersAlarm 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.3
Circuit Breaker Alarm. This setting indicates what action to perform in the event of a circuit breaker alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3ConfigFuses 1.3.6.1.4.1.318.1.1.7.2.6.2
OBJECT IDENTIFIER    

dm3ConfigFusesTableSize 1.3.6.1.4.1.318.1.1.7.2.6.2.1
The number of DC powerplant Fuses controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3ConfigFusesTable 1.3.6.1.4.1.318.1.1.7.2.6.2.2
Allows for accessing settings of the Fuses. The number of entries is contained in the dm3ConfigFusesTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3ConfigFusesEntry

dm3ConfigFusesEntry 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1
The fuse to configure.
OBJECT-TYPE    
  Dm3ConfigFusesEntry  

dm3ConfigFusesIndex 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.1
The index to the DC powerplant fuse.
OBJECT-TYPE    
  INTEGER  

dm3ConfigFusesName 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.2
The name of the fuse. The maximum value is 16 characters.
OBJECT-TYPE    
  DisplayString  

dm3ConfigFusesAlarm 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.3
Fuses Alarm. This setting indicates what action to perform in the event of a Fuse alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
OBJECT-TYPE    
  INTEGER alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)  

dm3Status 1.3.6.1.4.1.318.1.1.7.3
OBJECT IDENTIFIER    

dm3StatusSystem 1.3.6.1.4.1.318.1.1.7.3.1
OBJECT IDENTIFIER    

dm3StatusSystemTemp 1.3.6.1.4.1.318.1.1.7.3.1.1
System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dm3StatusSystemStart 1.3.6.1.4.1.318.1.1.7.3.1.2
Time stamp at DC powerplant initialization. The time is represented as MMM,DD,YYYY,HH:MM:SS.
OBJECT-TYPE    
  DisplayString  

dm3StatusSysRemoteAccess 1.3.6.1.4.1.318.1.1.7.3.1.3
Remote Access indicator This setting indicates if configuration (write) access to the powerplant is enabled or disabled at the powerplant level. This value will be accessEnabled (1) if remote configuration is enabled, and accessDisabled (2) if remote configuration is disabled.
OBJECT-TYPE    
  INTEGER accessEnabled(1), accessDisabled(2)  

dm3StatusSysSecurityLevel 1.3.6.1.4.1.318.1.1.7.3.1.4
This variable shows the current active security access level of controller. This can only be changed directly from the front panel.
OBJECT-TYPE    
  INTEGER  

dm3StatusSysTempSanity 1.3.6.1.4.1.318.1.1.7.3.1.5
System temperature sanity indicator. Indicates if the system temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not.
OBJECT-TYPE    
  INTEGER saneYES(1), saneNO(2)  

dm3StatusSysAlarmState 1.3.6.1.4.1.318.1.1.7.3.1.6
System Alarm State. Reflects the alarm status of the overall DC system. If a minor alarm is present, the value will be alarmMinor(1). If a major alarm is present, the value will be alarmMajor(2). If both minor and a major alarm is present, the value will be alarmBoth(3). If no alarm is present, the value will be alarmNone(4).
OBJECT-TYPE    
  INTEGER alarmMinor(1), alarmMajor(2), alarmBoth(3), alarmNone(4)  

dm3StatusSysTempUnits 1.3.6.1.4.1.318.1.1.7.3.1.7
The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

dm3StatusAlarms 1.3.6.1.4.1.318.1.1.7.3.2
OBJECT IDENTIFIER    

dm3StatusAlarmsTableSize 1.3.6.1.4.1.318.1.1.7.3.2.1
The number of DC powerplant alarms viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusAlarmsTable 1.3.6.1.4.1.318.1.1.7.3.2.2
Allows for accessing system alarms. The number of entries is contained in the dm3StatusAlarmsTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusAlarmsEntry

dm3StatusAlarmsEntry 1.3.6.1.4.1.318.1.1.7.3.2.2.1
The alarm to display.
OBJECT-TYPE    
  Dm3StatusAlarmsEntry  

dm3StatusAlarmsIndex 1.3.6.1.4.1.318.1.1.7.3.2.2.1.1
The index of the system alarm.
OBJECT-TYPE    
  INTEGER  

dm3StatusAlarmsText 1.3.6.1.4.1.318.1.1.7.3.2.2.1.2
The 16 character text describing the active alarm condition.
OBJECT-TYPE    
  DisplayString  

dm3StatusBattery 1.3.6.1.4.1.318.1.1.7.3.3
OBJECT IDENTIFIER    

dm3StatusBattCurrent 1.3.6.1.4.1.318.1.1.7.3.3.1
Battery Current: This OID shows the battery current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusBattTemp 1.3.6.1.4.1.318.1.1.7.3.3.2
Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dm3StatusBattCurrentSanity 1.3.6.1.4.1.318.1.1.7.3.3.3
Battery current sanity indicator. Indicates if the battery current is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates current is reasonable, a value of saneNo (2) indicates it is not.
OBJECT-TYPE    
  INTEGER saneYES(1), saneNO(2)  

dm3StatusBattTempSanity 1.3.6.1.4.1.318.1.1.7.3.3.4
Battery temperature sanity indicator. Indicates if the battery temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not.
OBJECT-TYPE    
  INTEGER saneYES(1), saneNO(2)  

dm3StatusOEM 1.3.6.1.4.1.318.1.1.7.3.4
OBJECT IDENTIFIER    

dm3StatusOEMrectOffset 1.3.6.1.4.1.318.1.1.7.3.4.1
This OID shows the rectifier offset value in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dm3StatusOEMrectGain 1.3.6.1.4.1.318.1.1.7.3.4.2
This OID shows the rectifier gain value in thousandths of Volts (mV/V).
OBJECT-TYPE    
  INTEGER  

dm3StatusOEMconvOffset 1.3.6.1.4.1.318.1.1.7.3.4.3
This OID shows the converter offset value in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dm3StatusOEMconvGain 1.3.6.1.4.1.318.1.1.7.3.4.4
This OID shows the converter gain value in thousandths of Volts (mV/V).
OBJECT-TYPE    
  INTEGER  

dm3StatusOEMshuntOffset 1.3.6.1.4.1.318.1.1.7.3.4.5
This OID shows the shunt offset value in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusOEMshuntGain 1.3.6.1.4.1.318.1.1.7.3.4.6
This OID shows the shunt gain value in thousandths of Amps (mA/A).
OBJECT-TYPE    
  INTEGER  

dm3StatusLVD 1.3.6.1.4.1.318.1.1.7.3.5
OBJECT IDENTIFIER    

dm3StatusLVDTableSize 1.3.6.1.4.1.318.1.1.7.3.5.1
The number of DC powerplant LVDs viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusLVDTable 1.3.6.1.4.1.318.1.1.7.3.5.2
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3StatusLVDTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusLVDEntry

dm3StatusLVDEntry 1.3.6.1.4.1.318.1.1.7.3.5.2.1
The LVD to gather status from.
OBJECT-TYPE    
  Dm3StatusLVDEntry  

dm3StatusLVDIndex 1.3.6.1.4.1.318.1.1.7.3.5.2.1.1
The index to the DC powerplant LVD.
OBJECT-TYPE    
  INTEGER  

dm3StatusLVDName 1.3.6.1.4.1.318.1.1.7.3.5.2.1.2
The name of the LVD. The maximum size is 16 characters. The name is set by using the dm3ConfigLVDName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

dm3StatusLVDState 1.3.6.1.4.1.318.1.1.7.3.5.2.1.3
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
OBJECT-TYPE    
  INTEGER statusClosed(1), statusOpened(2)  

dm3StatusLVDHwFault 1.3.6.1.4.1.318.1.1.7.3.5.2.1.4
Getting this OID will return statusFault (1) if the LVD is faulted. statusNofault (2) will be returned if the LVD is not faulted.
OBJECT-TYPE    
  INTEGER statusFault(1), statusNofault(2)  

dm3StatusPowerModules 1.3.6.1.4.1.318.1.1.7.3.6
OBJECT IDENTIFIER    

dm3StatusRectifier 1.3.6.1.4.1.318.1.1.7.3.6.1
OBJECT IDENTIFIER    

dm3StatusRectTableSize 1.3.6.1.4.1.318.1.1.7.3.6.1.1
The number of DC powerplant rectifiers viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectTable 1.3.6.1.4.1.318.1.1.7.3.6.1.2
Allows for accessing settings of the rectifiers. The number of entries is contained in the dm3StatusRectTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusRectEntry

dm3StatusRectEntry 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1
The rectifier to gather status from.
OBJECT-TYPE    
  Dm3StatusRectEntry  

dm3StatusRectIndex 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.1
The index to the DC powerplant rectifier.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectID 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.2
This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectDesc 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.3
This OID shows the 16-character rectifier description.
OBJECT-TYPE    
  DisplayString  

dm3StatusRectCurrent 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.4
This OID shows the rectifier current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusRectCurrentLimit 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.5
Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state. statusFalse (2) will be returned if the rectifier is not in the Current Limit state.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectStandby 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.6
Getting this OID will return statusTrue (1) if the rectifier is in the Standby state. statusFalse (2) will be returned if the rectifier is not in the Standby state.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectFanFail 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.7
Getting this OID will return statusTrue (1) if the rectifier Fan has failed. statusFalse (2) will be returned if the rectifier Fan has not failed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectFail 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.8
Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectDevType 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.9
This OID shows the rectifier device type.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectPhyAddr 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.10
This OID shows the rectifier physical address (the address on the bus).
OBJECT-TYPE    
  INTEGER  

dm3StatusRectCfg 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.11
Getting this OID will return statusTrue (1) if the rectifier is present after power-up or set-configuration. statusFalse (2) will be returned if the rectifier is not configured.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectPcbRev 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.12
This OID shows the rectifier device PCB serial number.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectFwVer 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.13
This OID shows the rectifier device firmware revision.
OBJECT-TYPE    
  INTEGER  

dm3StatusRectPresent 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.14
Getting this OID will return statusTrue (1) if the rectifier is present. statusFalse (2) will be returned if the rectifier is not present.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectDiagPass 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.15
Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed. statusFalse (2) will be returned if the rectifier diagnostics have not passed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusRectState 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.16
This OID shows the rectifier device state as defined by the device status register.
OBJECT-TYPE    
  INTEGER  

dm3StatusSysRectVoltSanity 1.3.6.1.4.1.318.1.1.7.3.6.1.3
Rectifier voltage sanity indicator. Indicates if the rectifier voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not.
OBJECT-TYPE    
  INTEGER saneYES(1), saneNO(2)  

dm3StatusSysRectAvailable 1.3.6.1.4.1.318.1.1.7.3.6.1.4
Getting this OID will return statusTrue (1) if the rectifier is available. statusFalse (2) will be returned if the rectifier is not available.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusSysRectType 1.3.6.1.4.1.318.1.1.7.3.6.1.5
This OID shows the type of rectifier the system has. There can only be a single type of rectifier in the power plant
OBJECT-TYPE    
  INTEGER  

dm3StatusSysRectVoltage 1.3.6.1.4.1.318.1.1.7.3.6.1.6
This OID shows the system level rectifier voltage in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dm3StatusSysRectCurrent 1.3.6.1.4.1.318.1.1.7.3.6.1.7
This OID shows the system level rectifier current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusConverter 1.3.6.1.4.1.318.1.1.7.3.6.2
OBJECT IDENTIFIER    

dm3StatusConvTableSize 1.3.6.1.4.1.318.1.1.7.3.6.2.1
The number of DC powerplant converters viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvTable 1.3.6.1.4.1.318.1.1.7.3.6.2.2
Allows for viewing status of the converters. The number of entries is contained in the dm3StatusConvTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusConvEntry

dm3StatusConvEntry 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1
The converter to gather status from.
OBJECT-TYPE    
  Dm3StatusConvEntry  

dm3StatusConvIndex 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.1
The index to the DC powerplant converter.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvID 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.2
This OID shows the converter ID. This enumerates the number of the converter within a group of converters.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvDesc 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.3
This OID shows the 16 character converter description.
OBJECT-TYPE    
  DisplayString  

dm3StatusConvCurrent 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.4
This OID shows the converter current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusConvCurrentLimit 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.5
Getting this OID will return statusTrue (1) if the converter is in the Current Limit state. statusFalse (2) will be returned if the converter is not in the Current Limit state.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvStandby 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.6
Getting this OID will return statusTrue (1) if the converter is in the Standby state. statusFalse (2) will be returned if the converter is not in the Standby state.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvFanFail 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.7
Getting this OID will return statusTrue (1) if the converter Fan has failed. statusFalse (2) will be returned if the converter Fan has not failed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvFail 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.8
Getting this OID will return statusTrue (1) if the converter has failed. statusFalse (2) will be returned if the converter has not failed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvDevType 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.9
This OID shows the converter device type.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvPhyAddr 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.10
This OID shows the converter physical address (the address on the bus).
OBJECT-TYPE    
  INTEGER  

dm3StatusConvCfg 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.11
Getting this OID will return statusTrue (1) if the converter is present after power-up or set-configuration. statusFalse (2) will be returned if the converter is not configured.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvPcbRev 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.12
This OID shows the converter device PCB serial number.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvFwVer 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.13
This OID shows the converter device firmware version.
OBJECT-TYPE    
  INTEGER  

dm3StatusConvPresent 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.14
Getting this OID will return statusTrue (1) if the converter is present. statusFalse (2) will be returned if the converter is not present.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvDiagPass 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.15
Getting this OID will return statusTrue (1) if the converter diagnostics have passed. statusFalse (2) will be returned if the converter diagnostics have not passed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusConvState 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.16
This OID shows the converter state as defined by the device status register.
OBJECT-TYPE    
  INTEGER  

dm3StatusSysConvVoltSanity 1.3.6.1.4.1.318.1.1.7.3.6.2.3
Converter voltage sanity indicator. Indicates if the converter voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not.
OBJECT-TYPE    
  INTEGER saneYES(1), saneNO(2)  

dm3StatusSysConvAvailable 1.3.6.1.4.1.318.1.1.7.3.6.2.4
Getting this OID will return statusTrue (1) if the converter is available. statusFalse (2) will be returned if the converter is not available.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dm3StatusSysConvType 1.3.6.1.4.1.318.1.1.7.3.6.2.5
This OID shows the converter type.
OBJECT-TYPE    
  INTEGER  

dm3StatusSysConvVoltage 1.3.6.1.4.1.318.1.1.7.3.6.2.6
This OID shows the system level converter voltage in thousandths of volts (mV).
OBJECT-TYPE    
  INTEGER  

dm3StatusSysConvCurrent 1.3.6.1.4.1.318.1.1.7.3.6.2.7
This OID shows the system level converter current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dm3StatusRelays 1.3.6.1.4.1.318.1.1.7.3.7
OBJECT IDENTIFIER    

dm3StatusOutputRelays 1.3.6.1.4.1.318.1.1.7.3.7.1
OBJECT IDENTIFIER    

dm3StatusOutRlyTableSize 1.3.6.1.4.1.318.1.1.7.3.7.1.1
The number of DC powerplant output relays viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusOutRlyTable 1.3.6.1.4.1.318.1.1.7.3.7.1.2
Allows for viewing status of the output relays. The number of entries is contained in the dm3StatusOutRlyTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusOutRlyEntry

dm3StatusOutRlyEntry 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1
The output relay to gather status from.
OBJECT-TYPE    
  Dm3StatusOutRlyEntry  

dm3StatusOutRlyIndex 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.1
The index to the DC powerplant output relay.
OBJECT-TYPE    
  INTEGER  

dm3StatusOutRlyName 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.2
The name of the output relay. The maximum size is 16 characters. The name is set by using the dm3ConfigOutRlyName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

dm3StatusOutRlyStatus 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.3
Getting this OID will return statusOn (1) if the output relay is enabled/on. statusOff (2) will be returned if the output relay is disabled/off.
OBJECT-TYPE    
  INTEGER statusOn(1), statusOff(2)  

dm3StatusInputRelays 1.3.6.1.4.1.318.1.1.7.3.7.2
OBJECT IDENTIFIER    

dm3StatusInRlyTableSize 1.3.6.1.4.1.318.1.1.7.3.7.2.1
The number of DC powerplant input relays viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusInRlyTable 1.3.6.1.4.1.318.1.1.7.3.7.2.2
Allows for viewing status of the input relays. The number of entries is contained in the dm3StatusInRlyTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusInRlyEntry

dm3StatusInRlyEntry 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1
The input relays to gather status from.
OBJECT-TYPE    
  Dm3StatusInRlyEntry  

dm3StatusInRlyIndex 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.1
The index to the DC powerplant input relay.
OBJECT-TYPE    
  INTEGER  

dm3StatusInRlyName 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.2
The name of the input relay. The maximum size is 16 characters. The name is set by using the dm3ConfigInRlyName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

dm3StatusInRlyStatus 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.3
Getting this OID will return statusOn (1) if the input relay is enabled/on. statusOff (2) will be returned if the input relay is disabled/off.
OBJECT-TYPE    
  INTEGER statusOn(1), statusOff(2)  

dm3StatusDistribution 1.3.6.1.4.1.318.1.1.7.3.8
OBJECT IDENTIFIER    

dm3StatusBreakers 1.3.6.1.4.1.318.1.1.7.3.8.1
OBJECT IDENTIFIER    

dm3StatusBreakersTableSize 1.3.6.1.4.1.318.1.1.7.3.8.1.1
The number of DC powerplant circuit breakers viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusBreakersTable 1.3.6.1.4.1.318.1.1.7.3.8.1.2
Allows for viewing status of the circuit breakers. The number of entries is contained in the dm3StatusBreakersTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusBreakersEntry

dm3StatusBreakersEntry 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1
The circuit breaker to gather status from.
OBJECT-TYPE    
  Dm3StatusBreakersEntry  

dm3StatusBreakersIndex 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.1
The index to the DC powerplant circuit breaker.
OBJECT-TYPE    
  INTEGER  

dm3StatusBreakersName 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.2
The name of the circuit breaker. The maximum size is 16 characters. The name is set by using the dm3ConfigBreakersName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

dm3StatusBreakersStatus 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.3
Getting this OID will return statusClosed (1) if the circuit breaker is closed. statusOpen (2) will be returned if the circuit breaker is open.
OBJECT-TYPE    
  INTEGER statusClosed(1), statusOpen(2)  

dm3StatusFuses 1.3.6.1.4.1.318.1.1.7.3.8.2
OBJECT IDENTIFIER    

dm3StatusFusesTableSize 1.3.6.1.4.1.318.1.1.7.3.8.2.1
The number of DC powerplant fuses controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dm3StatusFusesTable 1.3.6.1.4.1.318.1.1.7.3.8.2.2
Allows for viewing status of the fuses. The number of entries is contained in the dm3StatusFusesTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dm3StatusFusesEntry

dm3StatusFusesEntry 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1
The fuse to gather status from.
OBJECT-TYPE    
  Dm3StatusFusesEntry  

dm3StatusFusesIndex 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.1
The index to the DC powerplant fuse.
OBJECT-TYPE    
  INTEGER  

dm3StatusFusesName 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.2
The name of the fuse. The maximum size is 16 characters. The name is set by using the dm3ConfigFuseName OID. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

dm3StatusFusesStatus 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.3
Getting this OID will return statusClosed (1) if the fuse is closed. statusOpen (2) will be returned if the fuse is open.
OBJECT-TYPE    
  INTEGER statusClosed(1), statusOpen(2)  

automaticTransferSwitch 1.3.6.1.4.1.318.1.1.8
OBJECT IDENTIFIER    

atsIdent 1.3.6.1.4.1.318.1.1.8.1
OBJECT IDENTIFIER    

atsIdentHardwareRev 1.3.6.1.4.1.318.1.1.8.1.1
The hardware revision of the Automatic Transfer Switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

atsIdentFirmwareRev 1.3.6.1.4.1.318.1.1.8.1.2
A string identifying the Automatic Transfer Switch firmware revision.
OBJECT-TYPE    
  DisplayString  

atsIdentFirmwareDate 1.3.6.1.4.1.318.1.1.8.1.3
The date of release for this Automatic Transfer Switch firmware revision.
OBJECT-TYPE    
  DisplayString  

atsIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.8.1.4
The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

atsIdentModelNumber 1.3.6.1.4.1.318.1.1.8.1.5
A string identifying the model number of the Automatic Transfer Switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

atsIdentSerialNumber 1.3.6.1.4.1.318.1.1.8.1.6
A string identifying the serial number of the Automatic Transfer Switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

atsIdentNominalLineVoltage 1.3.6.1.4.1.318.1.1.8.1.7
RMS Utility Voltage measured in Volts.
OBJECT-TYPE    
  INTEGER  

atsIdentNominalLineFrequency 1.3.6.1.4.1.318.1.1.8.1.8
Utility Power Frequency measured in Hertz.
OBJECT-TYPE    
  INTEGER  

atsIdentDeviceRating 1.3.6.1.4.1.318.1.1.8.1.9
This gives the device rating in Amps
OBJECT-TYPE    
  INTEGER  

atsCalibration 1.3.6.1.4.1.318.1.1.8.2
OBJECT IDENTIFIER    

atsCalibrationInput 1.3.6.1.4.1.318.1.1.8.2.1
OBJECT IDENTIFIER    

atsCalibrationNumInputs 1.3.6.1.4.1.318.1.1.8.2.1.1
The number of inputs to this device.
OBJECT-TYPE    
  INTEGER  

atsCalibrationNumInputPhases 1.3.6.1.4.1.318.1.1.8.2.1.2
The number of phases per input for this device.
OBJECT-TYPE    
  INTEGER  

atsCalibrationInputPhaseTable 1.3.6.1.4.1.318.1.1.8.2.1.3
The number of phases per input line to this device.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSCalibrationInputPhaseEntry

atsCalibrationInputPhaseEntry 1.3.6.1.4.1.318.1.1.8.2.1.3.1
An entry containing calibration information applicable to a particular input phase.
OBJECT-TYPE    
  ATSCalibrationInputPhaseEntry  

atsCalibrationInputTableIndex 1.3.6.1.4.1.318.1.1.8.2.1.3.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

atsCalibrationInputPhaseTableIndex 1.3.6.1.4.1.318.1.1.8.2.1.3.1.2
The input phase identifier.
OBJECT-TYPE    
  INTEGER  

atsLineVoltageCalibrationFactor 1.3.6.1.4.1.318.1.1.8.2.1.3.1.3
The Line Voltage Calibration factor. This value is set at the factory.
OBJECT-TYPE    
  INTEGER  

atsCalibrationPowerSupply 1.3.6.1.4.1.318.1.1.8.2.2
OBJECT IDENTIFIER    

atsCalibrationPowerSupplyVoltages 1.3.6.1.4.1.318.1.1.8.2.2.1
The number of power supply voltages supported by this device. This variable indicates the number of rows in the atsCalibrationPowerSupplyTable.
OBJECT-TYPE    
  INTEGER  

atsCalibrationPowerSupplyVoltageTable 1.3.6.1.4.1.318.1.1.8.2.2.2
A list of Power Supply table entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSCalibrationPowerSupplyVoltageEntry

atsCalibrationPowerSupplyVoltageEntry 1.3.6.1.4.1.318.1.1.8.2.2.2.1
An entry containing information applicable to a particular Power Supply Voltage.
OBJECT-TYPE    
  ATSCalibrationPowerSupplyVoltageEntry  

atsCalibrationPowerSupplyVoltageTableIndex 1.3.6.1.4.1.318.1.1.8.2.2.2.1.1
The power supply voltage identifier.
OBJECT-TYPE    
  INTEGER  

atsCalibrationPowerSupplyVoltage 1.3.6.1.4.1.318.1.1.8.2.2.2.1.2
This value describes the power supply voltage of 24V Source A, 24V Source B, +12V, -12V and 5V.
OBJECT-TYPE    
  INTEGER powerSupply24V(1), powerSupply12V(2), powerSupply(3), powerSupply24VSourceB(4), powerSupplyMinus12V(5)  

atsPowerSupplyVoltageCalibrationFactor 1.3.6.1.4.1.318.1.1.8.2.2.2.1.3
The Line Voltage Calibration factor. This value is set at the factory.
OBJECT-TYPE    
  INTEGER  

atsCalibrationOutput 1.3.6.1.4.1.318.1.1.8.2.3
OBJECT IDENTIFIER    

atsCalibrationNumOutputs 1.3.6.1.4.1.318.1.1.8.2.3.1
The number of output lines from this device. This variable indicates the number of rows in the atsCalibrationOutputTable.
OBJECT-TYPE    
  INTEGER  

atsCalibrationNumOutputPhases 1.3.6.1.4.1.318.1.1.8.2.3.2
The number of output phases utilized in this device.
OBJECT-TYPE    
  INTEGER  

atsCalibrationOutputTable 1.3.6.1.4.1.318.1.1.8.2.3.3
A list of output table entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSCalibrationOutputEntry

atsCalibrationOutputEntry 1.3.6.1.4.1.318.1.1.8.2.3.3.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  ATSCalibrationOutputEntry  

atsCalibrationOutputTableIndex 1.3.6.1.4.1.318.1.1.8.2.3.3.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

atsCalibrationOutputPhasesTableIndex 1.3.6.1.4.1.318.1.1.8.2.3.3.1.2
Description of each calibration factor for each output phase utilized in this device and one for neutral.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3), neutral(4)  

atsOutputCurrentCalibrationFactor 1.3.6.1.4.1.318.1.1.8.2.3.3.1.3
The output current calibration factor measured in Amps.
OBJECT-TYPE    
  INTEGER  

atsControl 1.3.6.1.4.1.318.1.1.8.3
OBJECT IDENTIFIER    

atsControlResetATS 1.3.6.1.4.1.318.1.1.8.3.1
Setting this variable will cause the Automatic Transfer Switch to perform a power-on reset.
OBJECT-TYPE    
  INTEGER none(1), reset(2)  

atsControlClearAllAlarms 1.3.6.1.4.1.318.1.1.8.3.2
Setting this variable will clear all alarms in the Automatic Transfer Switch. Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER none(1), clear(2)  

atsConfig 1.3.6.1.4.1.318.1.1.8.4
OBJECT IDENTIFIER    

atsConfigProductName 1.3.6.1.4.1.318.1.1.8.4.1
A configurable character string.
OBJECT-TYPE    
  DisplayString  

atsConfigPreferredSource 1.3.6.1.4.1.318.1.1.8.4.2
This variable returns the preferred source of power when both sources are OK.
OBJECT-TYPE    
  INTEGER sourceA(1), sourceB(2), none(3)  

atsConfigFrontPanelLockout 1.3.6.1.4.1.318.1.1.8.4.3
Setting this variable to disableFrontPanel(1), prevents source preference configuration of the Automatic Transfer Switch via the Front Panel. Setting this variable to enableFrontPanel(2)allows, source preference configuration of the Automatic Transfer Switch via the Front Panel.
OBJECT-TYPE    
  INTEGER disableFrontPanel(1), enableFrontPanel(2)  

atsConfigVoltageSensitivity 1.3.6.1.4.1.318.1.1.8.4.4
This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(2) for frequent small line voltage changes.
OBJECT-TYPE    
  INTEGER high(1), low(2)  

atsConfigTransferVoltageRange 1.3.6.1.4.1.318.1.1.8.4.5
This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the Automatic Transfer Switch will switch over (transfer) to the alternate power source.
OBJECT-TYPE    
  INTEGER wide(1), medium(2), narrow(3)  

atsConfigCurrentLimit 1.3.6.1.4.1.318.1.1.8.4.6
The threshold (in Amps) at which an Over Current Alarm will be generated. This OID returns the overload threshold value of the OID atsConfigPhaseOverLoadThreshold for the 1U ATS and OID atsConfigBankOverLoadThreshold of total for the 2U ATS. Setting this OID does not have any impact on the device.
OBJECT-TYPE    
  INTEGER 0..20  

atsConfigResetValues 1.3.6.1.4.1.318.1.1.8.4.7
Resets the ATS configuration to its default values. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER none(1), reset(2)  

atsConfigLineVRMS 1.3.6.1.4.1.318.1.1.8.4.8
To configure the input RMS voltage.
OBJECT-TYPE    
  INTEGER  

atsConfigLineVRMSNarrowLimit 1.3.6.1.4.1.318.1.1.8.4.9
To configure the Line VRMS Narrow Limit.
OBJECT-TYPE    
  INTEGER  

atsConfigLineVRMSMediumLimit 1.3.6.1.4.1.318.1.1.8.4.10
To configure the Line VRMS Medium Limit.
OBJECT-TYPE    
  INTEGER  

atsConfigLineVRMSWideLimit 1.3.6.1.4.1.318.1.1.8.4.11
To configure the Line VRMS Wide Limit.
OBJECT-TYPE    
  INTEGER  

atsConfigFrequencyDeviation 1.3.6.1.4.1.318.1.1.8.4.12
To configure the frequency deviation.
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3)  

atsConfigBankTableSize 1.3.6.1.4.1.318.1.1.8.4.13
The size of the bank table.
OBJECT-TYPE    
  INTEGER  

atsConfigBankTable 1.3.6.1.4.1.318.1.1.8.4.14
Allows for configuration of each ATS bank.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSConfigBankEntry

atsConfigBankEntry 1.3.6.1.4.1.318.1.1.8.4.14.1
This gives access to bank current threshold
OBJECT-TYPE    
  ATSConfigBankEntry  

atsConfigBankTableIndex 1.3.6.1.4.1.318.1.1.8.4.14.1.1
An index to the bank table entry.
OBJECT-TYPE    
  INTEGER  

atsConfigBank 1.3.6.1.4.1.318.1.1.8.4.14.1.2
The bank number of an ATS
OBJECT-TYPE    
  INTEGER total(1), bank1(2), bank2(3)  

atsConfigBankLowLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.14.1.3
A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigBankNearOverLoadThreshold OID.
OBJECT-TYPE    
  INTEGER  

atsConfigBankNearOverLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.14.1.4
A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigBankLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigBankOverLoadThreshold OID.
OBJECT-TYPE    
  INTEGER  

atsConfigBankOverLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.14.1.5
A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigBankNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID.
OBJECT-TYPE    
  INTEGER  

atsConfigPhaseTableSize 1.3.6.1.4.1.318.1.1.8.4.15
The size of the phase table.
OBJECT-TYPE    
  INTEGER  

atsConfigPhaseTable 1.3.6.1.4.1.318.1.1.8.4.16
Allows for configuration of each ATS phase.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSConfigPhaseEntry

atsConfigPhaseEntry 1.3.6.1.4.1.318.1.1.8.4.16.1
This gives access to phase threshold
OBJECT-TYPE    
  ATSConfigPhaseEntry  

atsConfigPhaseTableIndex 1.3.6.1.4.1.318.1.1.8.4.16.1.1
The index to the phase table entry.
OBJECT-TYPE    
  INTEGER  

atsConfigPhase 1.3.6.1.4.1.318.1.1.8.4.16.1.2
The phase number of an ATS
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

atsConfigPhaseLowLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.16.1.3
A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigPhaseNearOverLoadThreshold OID.
OBJECT-TYPE    
  INTEGER  

atsConfigPhaseNearOverLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.16.1.4
A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigPhaseLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigPhaseOverLoadThreshold OID.
OBJECT-TYPE    
  INTEGER  

atsConfigPhaseOverLoadThreshold 1.3.6.1.4.1.318.1.1.8.4.16.1.5
A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigPhaseNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID.
OBJECT-TYPE    
  INTEGER  

atsStatus 1.3.6.1.4.1.318.1.1.8.5
OBJECT IDENTIFIER    

atsStatusDeviceStatus 1.3.6.1.4.1.318.1.1.8.5.1
OBJECT IDENTIFIER    

atsStatusCommStatus 1.3.6.1.4.1.318.1.1.8.5.1.1
This variable returns the current communication status of the Automatic Transfer Switch.
OBJECT-TYPE    
  INTEGER atsNeverDiscovered(1), atsCommEstablished(2), atsCommLost(3)  

atsStatusSelectedSource 1.3.6.1.4.1.318.1.1.8.5.1.2
This variable returns the current source of power.
OBJECT-TYPE    
  INTEGER sourceA(1), sourceB(2)  

atsStatusRedundancyState 1.3.6.1.4.1.318.1.1.8.5.1.3
This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails. atsFullyRedundant(2) indicates that the ATS will switch over to the alternate power source if the current source fails.
OBJECT-TYPE    
  INTEGER atsRedundancyLost(1), atsFullyRedundant(2)  

atsStatusOverCurrentState 1.3.6.1.4.1.318.1.1.8.5.1.4
This variable returns the output current state of the ATS. atsOverCurrent(1) indicates that the ATS has exceeded the output current threshold and will not allow a switch over to the alternate power source if the current source fails. atsCurrentOK(2) indicates that the output current is below the output current threshold. This OID returns the value of the OID atsOutputPhaseState for the 1U ATS and OID atsOutputBankState for the 2U ATS.
OBJECT-TYPE    
  INTEGER atsOverCurrent(1), atsCurrentOK(2)  

atsStatus5VPowerSupply 1.3.6.1.4.1.318.1.1.8.5.1.5
This variable returns the present state of the ATS 5V power supply. atsPowerSupplyFailure(1) indicates the 5V power supply has failed and that the ATS serial port Configuration Menu is not accessible . atsPowerSupplyOK(2) indicates that the ATS 5V power supply is operating within tolerance.
OBJECT-TYPE    
  INTEGER atsPowerSupplyFailure(1), atsPowerSupplyOK(2)  

atsStatus24VPowerSupply 1.3.6.1.4.1.318.1.1.8.5.1.6
This variable returns the present state of the ATS 24V power supply for Source A. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance.
OBJECT-TYPE    
  INTEGER atsPowerSupplyFailure(1), atsPowerSupplyOK(2)  

atsStatus24VSourceBPowerSupply 1.3.6.1.4.1.318.1.1.8.5.1.7
This variable returns the present state of the ATS 24V power supply for Source B. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance.
OBJECT-TYPE    
  INTEGER atsPowerSupplyFailure(1), atsPowerSupplyOK(2)  

atsStatusPlus12VPowerSupply 1.3.6.1.4.1.318.1.1.8.5.1.8
This variable returns the present state of the ATS 12V power supply. atsPowerSupplyFailure(1) indicates the 12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS 12V power supply is operating within tolerance.
OBJECT-TYPE    
  INTEGER atsPowerSupplyFailure(1), atsPowerSupplyOK(2)  

atsStatusMinus12VPowerSupply 1.3.6.1.4.1.318.1.1.8.5.1.9
This variable returns the present state of the ATS -12V power supply. atsPowerSupplyFailure(1) indicates the -12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS -12V power supply is operating within tolerance.
OBJECT-TYPE    
  INTEGER atsPowerSupplyFailure(1), atsPowerSupplyOK(2)  

atsStatusSwitchStatus 1.3.6.1.4.1.318.1.1.8.5.1.10
This variable returns the status of the ATS.
OBJECT-TYPE    
  INTEGER fail(1), ok(2)  

atsStatusFrontPanel 1.3.6.1.4.1.318.1.1.8.5.1.11
This variable returns the present state of the ATS front panel. locked(1): Front panel button cannot be used to change the sources. unlocked(2): Front panel button can be used to change the sources.
OBJECT-TYPE    
  INTEGER locked(1), unlocked(2)  

atsStatusSourceAStatus 1.3.6.1.4.1.318.1.1.8.5.1.12
This variable returns the status of the Source A.
OBJECT-TYPE    
  INTEGER fail(1), ok(2)  

atsStatusSourceBStatus 1.3.6.1.4.1.318.1.1.8.5.1.13
This variable returns the status of the Source B.
OBJECT-TYPE    
  INTEGER fail(1), ok(2)  

atsStatusPhaseSyncStatus 1.3.6.1.4.1.318.1.1.8.5.1.14
This variable returns the status of the phase synch.
OBJECT-TYPE    
  INTEGER inSync(1), outOfSync(2)  

atsStatusVoltageOutStatus 1.3.6.1.4.1.318.1.1.8.5.1.15
This variable returns the output voltage status.
OBJECT-TYPE    
  INTEGER fail(1), ok(2)  

atsStatusHardwareStatus 1.3.6.1.4.1.318.1.1.8.5.1.16
This variable returns the status of display board hardware.
OBJECT-TYPE    
  INTEGER fail(1), ok(2)  

atsStatusResetValues 1.3.6.1.4.1.318.1.1.8.5.2
OBJECT IDENTIFIER    

atsStatusResetMaxMinValues 1.3.6.1.4.1.318.1.1.8.5.2.1
Resets the maximum and minimum ATS values: atsInputMaxVoltage, atsInputMinVoltage, atsInputMaxCurrent, atsInputMinCurrent, atsInputMaxPower, atsInputMinPower, atsOutputMaxCurrent, atsOutputMinCurrent, atsOutputMaxLoad, atsOutputMinLoad, atsOutputMaxPercentLoad, atsOutputMinPercentLoad, atsOutputMaxPower, atsOutputMinPower, atsOutputMaxPercentPower, atsOutputMinPercentPower. These variables represent the maximum and minimum ATS values since the last time they were read or reset by this OID. Values unsupported by this ATS will return (-1).
OBJECT-TYPE    
  INTEGER none(1), reset(2)  

atsStatusInput 1.3.6.1.4.1.318.1.1.8.5.3
OBJECT IDENTIFIER    

atsNumInputs 1.3.6.1.4.1.318.1.1.8.5.3.1
The number of input feeds to this device. This variable indicates the number of rows in the input table.
OBJECT-TYPE    
  INTEGER  

atsInputTable 1.3.6.1.4.1.318.1.1.8.5.3.2
A list of input table entries. The number of entries is given by the value of atsNumInputs.
OBJECT-TYPE    
  SEQUENCE OF  
    AtsInputEntry

atsInputEntry 1.3.6.1.4.1.318.1.1.8.5.3.2.1
An entry containing information applicable to a particular input.
OBJECT-TYPE    
  AtsInputEntry  

atsInputTableIndex 1.3.6.1.4.1.318.1.1.8.5.3.2.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

atsNumInputPhases 1.3.6.1.4.1.318.1.1.8.5.3.2.1.2
The number of input phases utilized in this device. The sum of all the atsNumInputPhases variable indicates the number of rows in the input phase table.
OBJECT-TYPE    
  INTEGER  

atsInputVoltageOrientation 1.3.6.1.4.1.318.1.1.8.5.3.2.1.3
The input voltage orientation: 1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
OBJECT-TYPE    
  INTEGER unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)  

atsInputFrequency 1.3.6.1.4.1.318.1.1.8.5.3.2.1.4
The input frequency in Hertz, or -1 if it's unsupported by this Source.
OBJECT-TYPE    
  INTEGER  

atsInputType 1.3.6.1.4.1.318.1.1.8.5.3.2.1.5
The input type.
OBJECT-TYPE    
  INTEGER unknown(1), main(2), bypass(3)  

atsInputName 1.3.6.1.4.1.318.1.1.8.5.3.2.1.6
A name given to a particular input.
OBJECT-TYPE    
  DisplayString  

atsInputPhaseTable 1.3.6.1.4.1.318.1.1.8.5.3.3
A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    AtsInputPhaseEntry

atsInputPhaseEntry 1.3.6.1.4.1.318.1.1.8.5.3.3.1
An entry containing information applicable to a particular input phase.
OBJECT-TYPE    
  AtsInputPhaseEntry  

atsInputPhaseTableIndex 1.3.6.1.4.1.318.1.1.8.5.3.3.1.1
The input identifier.
OBJECT-TYPE    
  INTEGER  

atsInputPhaseIndex 1.3.6.1.4.1.318.1.1.8.5.3.3.1.2
The input phase identifier.
OBJECT-TYPE    
  INTEGER  

atsInputVoltage 1.3.6.1.4.1.318.1.1.8.5.3.3.1.3
The input voltage in VAC, or -1 if it's unsupported by this Source.
OBJECT-TYPE    
  INTEGER  

atsInputMaxVoltage 1.3.6.1.4.1.318.1.1.8.5.3.3.1.4
The maximum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsInputMinVoltage 1.3.6.1.4.1.318.1.1.8.5.3.3.1.5
The minimum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsInputCurrent 1.3.6.1.4.1.318.1.1.8.5.3.3.1.6
The input current in amperes, or -1 if it's unsupported by this Source.
OBJECT-TYPE    
  INTEGER  

atsInputMaxCurrent 1.3.6.1.4.1.318.1.1.8.5.3.3.1.7
The maximum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsInputMinCurrent 1.3.6.1.4.1.318.1.1.8.5.3.3.1.8
The minimum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsInputPower 1.3.6.1.4.1.318.1.1.8.5.3.3.1.9
The input power in Watts, or -1 if it's unsupported by this Source.
OBJECT-TYPE    
  INTEGER  

atsInputMaxPower 1.3.6.1.4.1.318.1.1.8.5.3.3.1.10
The maximum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsInputMinPower 1.3.6.1.4.1.318.1.1.8.5.3.3.1.11
The minimum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsStatusOutput 1.3.6.1.4.1.318.1.1.8.5.4
OBJECT IDENTIFIER    

atsNumOutputs 1.3.6.1.4.1.318.1.1.8.5.4.1
The number of output feeds to this device. This variable indicates the number of rows in the output table.
OBJECT-TYPE    
  INTEGER  

atsOutputTable 1.3.6.1.4.1.318.1.1.8.5.4.2
A list of output table entries. The number of entries is given by the value of atsOutputNumPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    AtsOutputEntry

atsOutputEntry 1.3.6.1.4.1.318.1.1.8.5.4.2.1
An entry containing information applicable to a particular output.
OBJECT-TYPE    
  AtsOutputEntry  

atsOutputTableIndex 1.3.6.1.4.1.318.1.1.8.5.4.2.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

atsNumOutputPhases 1.3.6.1.4.1.318.1.1.8.5.4.2.1.2
The number of output phases utilized in this device. The sum of all the atsNumOutputPhases variable indicates the number of rows in the output phase table.
OBJECT-TYPE    
  INTEGER  

atsOutputVoltageOrientation 1.3.6.1.4.1.318.1.1.8.5.4.2.1.3
The output voltage orientation: 1: unknown for this ATS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
OBJECT-TYPE    
  INTEGER unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)  

atsOutputFrequency 1.3.6.1.4.1.318.1.1.8.5.4.2.1.4
The output frequency in Hertz, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputPhaseTable 1.3.6.1.4.1.318.1.1.8.5.4.3
A list of output table entries. The number of entries is given by the sum of the atsNumOutputPhases.
OBJECT-TYPE    
  SEQUENCE OF  
    AtsOutputPhaseEntry

atsOutputPhaseEntry 1.3.6.1.4.1.318.1.1.8.5.4.3.1
An entry containing information applicable to a particular output phase.
OBJECT-TYPE    
  AtsOutputPhaseEntry  

atsOutputPhaseTableIndex 1.3.6.1.4.1.318.1.1.8.5.4.3.1.1
The output identifier.
OBJECT-TYPE    
  INTEGER  

atsOutputPhaseIndex 1.3.6.1.4.1.318.1.1.8.5.4.3.1.2
Description of each output phase utilized in this device and one for neutral.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3), neutral(4)  

atsOutputVoltage 1.3.6.1.4.1.318.1.1.8.5.4.3.1.3
The output voltage in VAC, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputCurrent 1.3.6.1.4.1.318.1.1.8.5.4.3.1.4
The output current in 0.1 amperes drawn by the load on the ATS, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputMaxCurrent 1.3.6.1.4.1.318.1.1.8.5.4.3.1.5
The maximum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputMinCurrent 1.3.6.1.4.1.318.1.1.8.5.4.3.1.6
The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.7
The output load in VA, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputMaxLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.8
The maximum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputMinLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.9
The minimum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.10
The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputMaxPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.11
The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputMinPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.3.1.12
The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.13
The output power in Watts, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputMaxPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.14
The maximum output power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputMinPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.15
The minimum output power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.16
The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputMaxPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.17
The maximum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputMinPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.3.1.18
The minimum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputPhaseState 1.3.6.1.4.1.318.1.1.8.5.4.3.1.19
Getting this OID will return the phase load state. normal(1) indicates that the bank is operating properly within the atsConfigPhaseLowLoadThreshold and atsConfigPhaseNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigPhaseLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigPhaseNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigPhaseOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER normal(1), lowload(2), nearoverload(3), overload(4)  

atsOutputBankTableSize 1.3.6.1.4.1.318.1.1.8.5.4.4
The size of the bank table.
OBJECT-TYPE    
  INTEGER  

atsOutputBankTable 1.3.6.1.4.1.318.1.1.8.5.4.5
Allows for getting table entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ATSOutputBankEntry

atsOutputBankEntry 1.3.6.1.4.1.318.1.1.8.5.4.5.1
This gives access to bank table entries
OBJECT-TYPE    
  ATSOutputBankEntry  

atsOutputBankTableIndex 1.3.6.1.4.1.318.1.1.8.5.4.5.1.1
The index to the bank table entry.
OBJECT-TYPE    
  INTEGER  

atsOutputPhase 1.3.6.1.4.1.318.1.1.8.5.4.5.1.2
The phase number of an ATS
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

atsOutputBank 1.3.6.1.4.1.318.1.1.8.5.4.5.1.3
The bank number of an ATS
OBJECT-TYPE    
  INTEGER total(1), bank1(2), bank2(3)  

atsOutputBankCurrent 1.3.6.1.4.1.318.1.1.8.5.4.5.1.4
Getting this OID will return the bank current measured in tenths of Amps.
OBJECT-TYPE    
  Gauge  

atsOutputBankState 1.3.6.1.4.1.318.1.1.8.5.4.5.1.5
Getting this OID will return the bank load state. normal(1) indicates that the bank is operating properly within the atsConfigBankLowLoadThreshold and atsConfigBankNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigBankLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigBankNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigBankOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER normal(1), lowload(2), nearoverload(3), overload(4)  

atsOutputBankOutputVoltage 1.3.6.1.4.1.318.1.1.8.5.4.5.1.6
The output voltage in VAC, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMaxCurrent 1.3.6.1.4.1.318.1.1.8.5.4.5.1.7
The maximum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMinCurrent 1.3.6.1.4.1.318.1.1.8.5.4.5.1.8
The minimum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.9
The output load, on the bank represented by OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMaxLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.10
The maximum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMinLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.11
The minimum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.12
The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank. Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMaxPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.13
The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMinPercentLoad 1.3.6.1.4.1.318.1.1.8.5.4.5.1.14
The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.15
The output power in Watts on the bank represented by OID atsOutputBank or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMaxPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.16
The maximum output power in Watts measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMinPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.17
The minimum output power in Watts measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.18
The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, or -1 if it's unsupported by this ATS.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMaxPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.19
The maximum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

atsOutputBankMinPercentPower 1.3.6.1.4.1.318.1.1.8.5.4.5.1.20
The minimum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
OBJECT-TYPE    
  INTEGER  

dc2 1.3.6.1.4.1.318.1.1.9
OBJECT IDENTIFIER    

dcmim2Ident 1.3.6.1.4.1.318.1.1.9.1
OBJECT IDENTIFIER    

dcmim2IdentSystem 1.3.6.1.4.1.318.1.1.9.1.1
OBJECT IDENTIFIER    

dcmim2IdentSysFWVersion 1.3.6.1.4.1.318.1.1.9.1.1.1
Integer representation of the power plant Master Controller firmware revision.
OBJECT-TYPE    
  INTEGER  

dcmim2Control 1.3.6.1.4.1.318.1.1.9.2
OBJECT IDENTIFIER    

dcmim2ControlSystem 1.3.6.1.4.1.318.1.1.9.2.1
OBJECT IDENTIFIER    

dcmim2ControlRunFunctBatteryTest 1.3.6.1.4.1.318.1.1.9.2.1.1
Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery functional test off. Setting this OID to battTestOn (2) will turn the battery functional test on.
OBJECT-TYPE    
  INTEGER battTestOff(1), battTestOn(2)  

dcmim2ControlRunCapacityBatteryTest 1.3.6.1.4.1.318.1.1.9.2.1.2
Getting this OID will return the battery capacity test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery capacity test off. Setting this OID to battTestOn (2) will turn the battery capacity test on.
OBJECT-TYPE    
  INTEGER battTestOff(1), battTestOn(2)  

dcmim2Config 1.3.6.1.4.1.318.1.1.9.3
OBJECT IDENTIFIER    

dcmim2ConfigSystem 1.3.6.1.4.1.318.1.1.9.3.1
OBJECT IDENTIFIER    

dcmim2ConfigSysHighTempTrip 1.3.6.1.4.1.318.1.1.9.3.1.1
Trip level (threshold) at which System High Temp alarm condition is created. Range 28 to 100 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigSysHighTempReset 1.3.6.1.4.1.318.1.1.9.3.1.2
Level at which System High Temp alarm condition is reset (cleared). Range 25 to (upper temp - 3) (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigSysLowTempTrip 1.3.6.1.4.1.318.1.1.9.3.1.3
Trip level (threshold) at which System Low Temp alarm condition is created. Range -100 to 10 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigSysLowTempReset 1.3.6.1.4.1.318.1.1.9.3.1.4
Level at which System Low Temp alarm condition is reset (cleared). Range (lower temp + 3) to 13 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattery 1.3.6.1.4.1.318.1.1.9.3.2
OBJECT IDENTIFIER    

dcmim2ConfigBattFloatVolt 1.3.6.1.4.1.318.1.1.9.3.2.1
Battery Float Voltage defined at 25 degrees Celsius. Values are represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattMaxRecharge 1.3.6.1.4.1.318.1.1.9.3.2.2
Battery Maximum Recharge Rate. This is the maximum current used during battery charging. Values are represented in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattMfgCapacity 1.3.6.1.4.1.318.1.1.9.3.2.3
Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattType 1.3.6.1.4.1.318.1.1.9.3.2.4
Type of battery in the powerplant Valid values range from 0 to 254.
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattFunctTestDuration 1.3.6.1.4.1.318.1.1.9.3.2.5
Duration of the battery functional test. Values are represented in thousandths of seconds (mSecs).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattFunctTestThresh 1.3.6.1.4.1.318.1.1.9.3.2.6
Threshold the battery voltage of the system must remain above in order to pass the battery functional test. Values are represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattCapacityTestPercent 1.3.6.1.4.1.318.1.1.9.3.2.7
Threshold for good battery capacity test results. Values range from 0 to 100 percent.
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattCapacityTestEndThresh 1.3.6.1.4.1.318.1.1.9.3.2.8
Safeguard voltage at which battery capacity test will end if there is a battery problem. Values are represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigBattCapacityTestCurrent 1.3.6.1.4.1.318.1.1.9.3.2.9
Constant current value used during battery capacity testing. Values are represented in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigLVD 1.3.6.1.4.1.318.1.1.9.3.3
OBJECT IDENTIFIER    

dcmim2ConfigLVDTableSize 1.3.6.1.4.1.318.1.1.9.3.3.1
The number of DC powerplant LVDs controllable by this IP address.
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigLVDTable 1.3.6.1.4.1.318.1.1.9.3.3.2
Allows for accessing settings of the LVDs. The number of entries is contained in the dcmim2ConfigLVDTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dcmim2ConfigLVDEntry

dcmim2ConfigLVDEntry 1.3.6.1.4.1.318.1.1.9.3.3.2.1
The LVD to configure.
OBJECT-TYPE    
  Dcmim2ConfigLVDEntry  

dcmim2ConfigLVDIndex 1.3.6.1.4.1.318.1.1.9.3.3.2.1.1
The index to the DC powerplant LVD.
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigLVDTrip 1.3.6.1.4.1.318.1.1.9.3.3.2.1.2
LVD Trip threshold. System bus voltage at which LVD will trip (open) during a battery backup operation. Values are represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigLVDReset 1.3.6.1.4.1.318.1.1.9.3.3.2.1.3
LVD Reset threshold. System bus voltage at which LVD will reset (close) after AC power has been restored. Values are represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2ConfigLVDState 1.3.6.1.4.1.318.1.1.9.3.3.2.1.4
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
OBJECT-TYPE    
  INTEGER statusClosed(1), statusOpened(2)  

dcmim2Status 1.3.6.1.4.1.318.1.1.9.4
OBJECT IDENTIFIER    

dcmim2StatusSystem 1.3.6.1.4.1.318.1.1.9.4.1
OBJECT IDENTIFIER    

dcmim2StatusSysRectCurrent 1.3.6.1.4.1.318.1.1.9.4.1.1
System (Total Rectifier) current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusSysLoadCurrent 1.3.6.1.4.1.318.1.1.9.4.1.2
Load current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusSysBusVoltage 1.3.6.1.4.1.318.1.1.9.4.1.3
System bus voltage in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusSysAmbientTemp 1.3.6.1.4.1.318.1.1.9.4.1.4
System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusSysUpTime 1.3.6.1.4.1.318.1.1.9.4.1.5
Length of time since the DC Powerplant controller has been powered up.
OBJECT-TYPE    
  DisplayString  

dcmim2StatusSysTempUnits 1.3.6.1.4.1.318.1.1.9.4.1.6
The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

dcmim2StatusRectifier 1.3.6.1.4.1.318.1.1.9.4.2
OBJECT IDENTIFIER    

dcmim2StatusRectTableSize 1.3.6.1.4.1.318.1.1.9.4.2.1
The number of DC powerplant rectifiers viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusRectTable 1.3.6.1.4.1.318.1.1.9.4.2.2
Allows for accessing settings of the rectifiers. The number of entries is contained in the dcmim2StatusRectTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dcmim2StatusRectEntry

dcmim2StatusRectEntry 1.3.6.1.4.1.318.1.1.9.4.2.2.1
The rectifier to gather status from.
OBJECT-TYPE    
  Dcmim2StatusRectEntry  

dcmim2StatusRectIndex 1.3.6.1.4.1.318.1.1.9.4.2.2.1.1
The index to the DC powerplant rectifier.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusRectDevType 1.3.6.1.4.1.318.1.1.9.4.2.2.1.2
This OID shows the rectifier device type.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusRectID 1.3.6.1.4.1.318.1.1.9.4.2.2.1.3
This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusRectPhyAddr 1.3.6.1.4.1.318.1.1.9.4.2.2.1.4
This OID shows the rectifier physical address (the address on the bus).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusRectFail 1.3.6.1.4.1.318.1.1.9.4.2.2.1.5
Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed.
OBJECT-TYPE    
  INTEGER statusTrue(1), statusFalse(2)  

dcmim2StatusRectCurrent 1.3.6.1.4.1.318.1.1.9.4.2.2.1.6
This OID shows the individual rectifier current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattery 1.3.6.1.4.1.318.1.1.9.4.3
OBJECT IDENTIFIER    

dcmim2StatusBattFloatVolt 1.3.6.1.4.1.318.1.1.9.4.3.1
Battery Float Voltage represented in thousandths of Volts (mV).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattCurrent 1.3.6.1.4.1.318.1.1.9.4.3.2
Battery Current: This OID shows the battery current in thousandths of Amps (mA).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattTemp 1.3.6.1.4.1.318.1.1.9.4.3.3
Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattMfgCapacity 1.3.6.1.4.1.318.1.1.9.4.3.4
Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattTestCapacity 1.3.6.1.4.1.318.1.1.9.4.3.5
Battery capacity (Amp-Hour Size) as determined by the battery capacity test. Values are represented in thousandths of Amp hours (mAHr).
OBJECT-TYPE    
  INTEGER  

dcmim2StatusBattFunctTestResult 1.3.6.1.4.1.318.1.1.9.4.3.6
Results of the last battery functional test that was run.
OBJECT-TYPE    
  INTEGER functTestNotPerformed(1), functTestInProcess(2), functTestInterrupted(3), functTestPass(4), functTestFail(5)  

dcmim2StatusBattCapacityTestResult 1.3.6.1.4.1.318.1.1.9.4.3.7
Results of the last battery capacity test that was run.
OBJECT-TYPE    
  INTEGER capacityTestNotPerformed(1), capacityTestInProcess(2), capacityTestInterrupted(3), capacityTestPass(4), capacityTestFail(5)  

dcmim2StatusLVD 1.3.6.1.4.1.318.1.1.9.4.4
OBJECT IDENTIFIER    

dcmim2StatusLVDTableSize 1.3.6.1.4.1.318.1.1.9.4.4.1
The number of DC powerplant LVDs accessible by this IP address.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusLVDTable 1.3.6.1.4.1.318.1.1.9.4.4.2
Allows for accessing the LVDs. The number of entries is contained in the dcmim2StatusLVDTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dcmim2StatusLVDEntry

dcmim2StatusLVDEntry 1.3.6.1.4.1.318.1.1.9.4.4.2.1
The LVD to access.
OBJECT-TYPE    
  Dcmim2StatusLVDEntry  

dcmim2StatusLVDIndex 1.3.6.1.4.1.318.1.1.9.4.4.2.1.1
The index to the DC powerplant LVD.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusLVDState 1.3.6.1.4.1.318.1.1.9.4.4.2.1.2
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
OBJECT-TYPE    
  INTEGER statusClosed(1), statusOpened(2)  

dcmim2StatusAlarms 1.3.6.1.4.1.318.1.1.9.4.5
OBJECT IDENTIFIER    

dcmim2StatusAlarmsTableSize 1.3.6.1.4.1.318.1.1.9.4.5.1
The number of DC powerplant alarms viewable by this IP address.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusAlarmsTable 1.3.6.1.4.1.318.1.1.9.4.5.2
Allows for accessing system alarms. The number of entries is contained in the dcmim2StatusAlarmsTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    Dcmim2StatusAlarmsEntry

dcmim2StatusAlarmsEntry 1.3.6.1.4.1.318.1.1.9.4.5.2.1
The alarm to display.
OBJECT-TYPE    
  Dcmim2StatusAlarmsEntry  

dcmim2StatusAlarmsIndex 1.3.6.1.4.1.318.1.1.9.4.5.2.1.1
The index of the system alarm.
OBJECT-TYPE    
  INTEGER  

dcmim2StatusAlarmsText 1.3.6.1.4.1.318.1.1.9.4.5.2.1.2
The 16 character text describing the active alarm condition.
OBJECT-TYPE    
  DisplayString  

environmentalMonitor 1.3.6.1.4.1.318.1.1.10
OBJECT IDENTIFIER    

external 1.3.6.1.4.1.318.1.1.10.1
OBJECT IDENTIFIER    

emIdent 1.3.6.1.4.1.318.1.1.10.1.1
OBJECT IDENTIFIER    

emIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.10.1.1.1
The firmware revision of the Environmental Monitor.
OBJECT-TYPE    
  DisplayString  

emConfig 1.3.6.1.4.1.318.1.1.10.1.2
OBJECT IDENTIFIER    

emConfigProbesNumProbes 1.3.6.1.4.1.318.1.1.10.1.2.1
The number of temperature and humidity probes available.
OBJECT-TYPE    
  INTEGER  

emConfigProbesTable 1.3.6.1.4.1.318.1.1.10.1.2.2
A list of probes supported by the Environmental Monitor and their configurations.
OBJECT-TYPE    
  SEQUENCE OF  
    EmConfigProbesEntry

emConfigProbesEntry 1.3.6.1.4.1.318.1.1.10.1.2.2.1
The Environmental Monitor probe configurations.
OBJECT-TYPE    
  EmConfigProbesEntry  

emConfigProbeNumber 1.3.6.1.4.1.318.1.1.10.1.2.2.1.1
The index into an Environmental Monitor probe entry.
OBJECT-TYPE    
  INTEGER  

emConfigProbeName 1.3.6.1.4.1.318.1.1.10.1.2.2.1.2
A descriptive name of the probe set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

emConfigProbeHighTempThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.3
The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeLowTempThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.4
The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeTempUnits 1.3.6.1.4.1.318.1.1.10.1.2.2.1.5
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

emConfigProbeHighHumidThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.6
The high humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

emConfigProbeLowHumidThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.7
The low humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

emConfigProbeHighTempEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.8
The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeLowTempEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.9
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeHighHumidEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.10
The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeLowHumidEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.11
The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeMaxTempThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.12
The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeMinTempThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.13
The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeMaxHumidThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.14
The maximun humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

emConfigProbeMinHumidThreshold 1.3.6.1.4.1.318.1.1.10.1.2.2.1.15
The minimum humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

emConfigProbeMaxTempEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.16
The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeMinTempEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.17
The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeMaxHumidEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.18
The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeMinHumidEnable 1.3.6.1.4.1.318.1.1.10.1.2.2.1.19
The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigProbeTempHysteresis 1.3.6.1.4.1.318.1.1.10.1.2.2.1.20
The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeHumidHysteresis 1.3.6.1.4.1.318.1.1.10.1.2.2.1.21
The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emConfigProbeLocation 1.3.6.1.4.1.318.1.1.10.1.2.2.1.22
A string describing the location of the probe.
OBJECT-TYPE    
  DisplayString  

emConfigContactsNumContacts 1.3.6.1.4.1.318.1.1.10.1.2.3
The number of contacts supported by the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

emConfigContactsTable 1.3.6.1.4.1.318.1.1.10.1.2.4
A list of contacts supported by the Environmental Monitor and their configurations.
OBJECT-TYPE    
  SEQUENCE OF  
    EmConfigContactsEntry

emConfigContactsEntry 1.3.6.1.4.1.318.1.1.10.1.2.4.1
The Environmental Monitor contact configurations.
OBJECT-TYPE    
  EmConfigContactsEntry  

emConfigContactNumber 1.3.6.1.4.1.318.1.1.10.1.2.4.1.1
The index of an Environmental Monitor contact.
OBJECT-TYPE    
  INTEGER  

emConfigContactName 1.3.6.1.4.1.318.1.1.10.1.2.4.1.2
A descriptive name for an Environmental Monitor contact set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

emConfigContactEnable 1.3.6.1.4.1.318.1.1.10.1.2.4.1.3
An Environmental Monitor contact alarm enable/disable. No alarm will be generated if the contact is disabled(1). An alarm will be generated if the contact is enabled(2) and the contact has been faulted.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

emConfigContactSeverity 1.3.6.1.4.1.318.1.1.10.1.2.4.1.4
The severity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3).
OBJECT-TYPE    
  INTEGER critical(1), warning(2), informational(3)  

emConfigContactNormalState 1.3.6.1.4.1.318.1.1.10.1.2.4.1.5
The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

emConfigContactLocation 1.3.6.1.4.1.318.1.1.10.1.2.4.1.6
A descriptive label for the contact denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

emStatus 1.3.6.1.4.1.318.1.1.10.1.3
OBJECT IDENTIFIER    

emStatusCommStatus 1.3.6.1.4.1.318.1.1.10.1.3.1
The communication status between the agent and the Environmental Monitor. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost.
OBJECT-TYPE    
  INTEGER noComm(1), comm(2), commLost(3)  

emStatusProbesNumProbes 1.3.6.1.4.1.318.1.1.10.1.3.2
The number of available probes on the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

emStatusProbesTable 1.3.6.1.4.1.318.1.1.10.1.3.3
A list of probes supported by the Environmental Monitor and their status.
OBJECT-TYPE    
  SEQUENCE OF  
    EmStatusProbesEntry

emStatusProbesEntry 1.3.6.1.4.1.318.1.1.10.1.3.3.1
The status of the probe.
OBJECT-TYPE    
  EmStatusProbesEntry  

emStatusProbeNumber 1.3.6.1.4.1.318.1.1.10.1.3.3.1.1
The index of the probe.
OBJECT-TYPE    
  INTEGER  

emStatusProbeName 1.3.6.1.4.1.318.1.1.10.1.3.3.1.2
A descriptive name for the probe set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

emStatusProbeStatus 1.3.6.1.4.1.318.1.1.10.1.3.3.1.3
The connected status of the probe, either disconnected(1) or connected(2).
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

emStatusProbeCurrentTemp 1.3.6.1.4.1.318.1.1.10.1.3.3.1.4
The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emStatusProbeTempUnits 1.3.6.1.4.1.318.1.1.10.1.3.3.1.5
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

emStatusProbeCurrentHumid 1.3.6.1.4.1.318.1.1.10.1.3.3.1.6
The current humidity reading from the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

emStatusProbeHighTempViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.7
The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'emConfigProbeHighTempThreshold' OID, and the value of the 'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), highTempViolation(2), disabled(3)  

emStatusProbeLowTempViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.8
The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'emConfigProbeLowTempThreshold' OID, and the value of the 'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), lowTempViolation(2), disabled(3)  

emStatusProbeHighHumidViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.9
The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'emConfigProbeHighHumidThreshold' OID, and the value of the 'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3)
OBJECT-TYPE    
  INTEGER noViolation(1), highHumidViolation(2), disabled(3)  

emStatusProbeLowHumidViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.10
The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'emConfigProbeLowHumidThreshold' OID, and the value of the 'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), lowHumidViolation(2), disabled(3)  

emStatusProbeMaxTempViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.11
The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'emConfigProbeMaxTempThreshold' OID, and the value of the 'emConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), maxTempViolation(2), disabled(3)  

emStatusProbeMinTempViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.12
The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'emConfigProbeMinTempThreshold' OID, and the value of the 'emConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), minTempViolation(2), disabled(3)  

emStatusProbeMaxHumidViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.13
The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'emConfigProbeMaxHumidThreshold' OID, and the value of the 'emConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3)
OBJECT-TYPE    
  INTEGER noViolation(1), maxHumidViolation(2), disabled(3)  

emStatusProbeMinHumidViolation 1.3.6.1.4.1.318.1.1.10.1.3.3.1.14
The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'emConfigProbeMinHumidThreshold' OID, and the value of the 'emConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), minHumidViolation(2), disabled(3)  

emStatusContactsNumContacts 1.3.6.1.4.1.318.1.1.10.1.3.4
The number of contacts supported by the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

emStatusContactsTable 1.3.6.1.4.1.318.1.1.10.1.3.5
A list of contacts supported by the Environmental Monitor and their status.
OBJECT-TYPE    
  SEQUENCE OF  
    EmStatusContactsEntry

emStatusContactsEntry 1.3.6.1.4.1.318.1.1.10.1.3.5.1
The status of the contact.
OBJECT-TYPE    
  EmStatusContactsEntry  

emStatusContactNumber 1.3.6.1.4.1.318.1.1.10.1.3.5.1.1
The index of the Environmental Monitor contact.
OBJECT-TYPE    
  INTEGER  

emStatusContactName 1.3.6.1.4.1.318.1.1.10.1.3.5.1.2
A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

emStatusContactStatus 1.3.6.1.4.1.318.1.1.10.1.3.5.1.3
The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'emConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'emContactEnable' OID is enabled. If the 'emConfigContactEnable' OID is disabled, the status will show disabled(3).
OBJECT-TYPE    
  INTEGER noFault(1), fault(2), disabled(3)  

integrated 1.3.6.1.4.1.318.1.1.10.2
OBJECT IDENTIFIER    

iemIdent 1.3.6.1.4.1.318.1.1.10.2.1
OBJECT IDENTIFIER    

iemIdentHardwareRevision 1.3.6.1.4.1.318.1.1.10.2.1.1
The hardware revision of the Integrated Environmental Monitor.
OBJECT-TYPE    
  DisplayString  

iemConfig 1.3.6.1.4.1.318.1.1.10.2.2
OBJECT IDENTIFIER    

iemConfigProbesNumProbes 1.3.6.1.4.1.318.1.1.10.2.2.1
The number of temperature and humidity probes available.
OBJECT-TYPE    
  INTEGER  

iemConfigProbesTable 1.3.6.1.4.1.318.1.1.10.2.2.2
A list of probes supported by the Environmental Monitor and their configurations.
OBJECT-TYPE    
  SEQUENCE OF  
    IemConfigProbesEntry

iemConfigProbesEntry 1.3.6.1.4.1.318.1.1.10.2.2.2.1
The Environmental Monitor probe configurations.
OBJECT-TYPE    
  IemConfigProbesEntry  

iemConfigProbeNumber 1.3.6.1.4.1.318.1.1.10.2.2.2.1.1
The index to a Environmental Monitor probe entry.
OBJECT-TYPE    
  INTEGER  

iemConfigProbeName 1.3.6.1.4.1.318.1.1.10.2.2.2.1.2
A descriptive name for the probe set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemConfigProbeHighTempThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.3
The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeLowTempThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.4
The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeTempUnits 1.3.6.1.4.1.318.1.1.10.2.2.2.1.5
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

iemConfigProbeHighHumidThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.6
The high humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

iemConfigProbeLowHumidThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.7
The low humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

iemConfigProbeHighTempEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.8
The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeLowTempEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.9
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeHighHumidEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.10
The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeLowHumidEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.11
The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeMaxTempThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.12
The maximun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeMinTempThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.13
The minimun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeMaxHumidThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.14
The maximum humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

iemConfigProbeMinHumidThreshold 1.3.6.1.4.1.318.1.1.10.2.2.2.1.15
The minimum humidity alarm threshold for the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

iemConfigProbeMaxTempEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.16
The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeMinTempEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.17
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeMaxHumidEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.18
The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeMinHumidEnable 1.3.6.1.4.1.318.1.1.10.2.2.2.1.19
The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigProbeTempHysteresis 1.3.6.1.4.1.318.1.1.10.2.2.2.1.20
The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeHumidHysteresis 1.3.6.1.4.1.318.1.1.10.2.2.2.1.21
The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemConfigProbeLocation 1.3.6.1.4.1.318.1.1.10.2.2.2.1.22
A string describing the location of the probe.
OBJECT-TYPE    
  DisplayString  

iemConfigContactsNumContacts 1.3.6.1.4.1.318.1.1.10.2.2.3
The number of contacts available on the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

iemConfigContactsTable 1.3.6.1.4.1.318.1.1.10.2.2.4
A list of contacts supported by the Environmental Monitor and their configurations.
OBJECT-TYPE    
  SEQUENCE OF  
    IemConfigContactsEntry

iemConfigContactsEntry 1.3.6.1.4.1.318.1.1.10.2.2.4.1
The Environmental Monitor contact configurations.
OBJECT-TYPE    
  IemConfigContactsEntry  

iemConfigContactNumber 1.3.6.1.4.1.318.1.1.10.2.2.4.1.1
The index of an Environmental Monitor contact.
OBJECT-TYPE    
  INTEGER  

iemConfigContactName 1.3.6.1.4.1.318.1.1.10.2.2.4.1.2
A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemConfigContactEnable 1.3.6.1.4.1.318.1.1.10.2.2.4.1.3
An Environmental Monitor contact alarm enable/disable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

iemConfigContactSeverity 1.3.6.1.4.1.318.1.1.10.2.2.4.1.4
The severtity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). NOTE: informational(3) is deprecated (and no longer valid) for this OID.
OBJECT-TYPE    
  INTEGER critical(1), warning(2), informational(3)  

iemConfigContactNormalState 1.3.6.1.4.1.318.1.1.10.2.2.4.1.5
The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

iemConfigContactLocation 1.3.6.1.4.1.318.1.1.10.2.2.4.1.6
A descriptive label for the contact denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemConfigConfigRelaysNumRelays 1.3.6.1.4.1.318.1.1.10.2.2.5
The number of output relays supported by the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

iemConfigRelaysTable 1.3.6.1.4.1.318.1.1.10.2.2.6
A list of output relays supported by the Environmental Monitor and their configurations.
OBJECT-TYPE    
  SEQUENCE OF  
    IemConfigRelaysEntry

iemConfigRelaysEntry 1.3.6.1.4.1.318.1.1.10.2.2.6.1
The Environmental Monitor output relay configurations.
OBJECT-TYPE    
  IemConfigRelaysEntry  

iemConfigRelayNumber 1.3.6.1.4.1.318.1.1.10.2.2.6.1.1
The index of an Environmental Monitor output relay.
OBJECT-TYPE    
  INTEGER  

iemConfigRelayName 1.3.6.1.4.1.318.1.1.10.2.2.6.1.2
A descriptive name of an Environmental Monitor output relay, set by the user, describing its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemConfigRelayNormalState 1.3.6.1.4.1.318.1.1.10.2.2.6.1.3
The normal state (non-fault state) of an Environmental Monitor output relay, either open(1) or closed(2).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

iemConfigRelayFaultCondition 1.3.6.1.4.1.318.1.1.10.2.2.6.1.4
The fault condition used to activate the output relay.
OBJECT-TYPE    
  INTEGER  

iemStatus 1.3.6.1.4.1.318.1.1.10.2.3
OBJECT IDENTIFIER    

iemStatusProbesNumProbes 1.3.6.1.4.1.318.1.1.10.2.3.1
The number of available probes on the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

iemStatusProbesTable 1.3.6.1.4.1.318.1.1.10.2.3.2
A list of probes supported by the Environmental Monitor and their status.
OBJECT-TYPE    
  SEQUENCE OF  
    IemStatusProbesEntry

iemStatusProbesEntry 1.3.6.1.4.1.318.1.1.10.2.3.2.1
The status of the probe.
OBJECT-TYPE    
  IemStatusProbesEntry  

iemStatusProbeNumber 1.3.6.1.4.1.318.1.1.10.2.3.2.1.1
The index of the probe.
OBJECT-TYPE    
  INTEGER  

iemStatusProbeName 1.3.6.1.4.1.318.1.1.10.2.3.2.1.2
A descriptive name for the probe set by the user.
OBJECT-TYPE    
  DisplayString  

iemStatusProbeStatus 1.3.6.1.4.1.318.1.1.10.2.3.2.1.3
The connected status of the probe, either disconnected(1) or connected(2).
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

iemStatusProbeCurrentTemp 1.3.6.1.4.1.318.1.1.10.2.3.2.1.4
The current temperature reading from the probe displayed in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

iemStatusProbeTempUnits 1.3.6.1.4.1.318.1.1.10.2.3.2.1.5
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

iemStatusProbeCurrentHumid 1.3.6.1.4.1.318.1.1.10.2.3.2.1.6
The current humidity reading from the probe in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

iemStatusProbeHighTempViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.7
The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'iemConfigProbeHighTempThreshold' OID, and the value of the 'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), highTempViolation(2), disabled(3)  

iemStatusProbeLowTempViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.8
The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'iemConfigProbeLowTempThreshold' OID, and the value of the 'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), lowTempViolation(2), disabled(3)  

iemStatusProbeHighHumidViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.9
The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'iemConfigProbeHighHumidThreshold' OID, and the value of the 'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), highHumidViolation(2), disabled(3)  

iemStatusProbeLowHumidViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.10
The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'iemConfigProbeLowHumidThreshold' OID, and the value of the 'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), lowHumidViolation(2), disabled(3)  

iemStatusProbeMaxTempViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.11
The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'iemConfigProbeMaxTempThreshold' OID, and the value of the 'iemConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), maxTempViolation(2), disabled(3)  

iemStatusProbeMinTempViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.12
The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'iemConfigProbeMinTempThreshold' OID, and the value of the 'iemConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), minTempViolation(2), disabled(3)  

iemStatusProbeMaxHumidViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.13
The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'iemConfigProbeMaxHumidThreshold' OID, and the value of the 'iemConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3)
OBJECT-TYPE    
  INTEGER noViolation(1), maxHumidViolation(2), disabled(3)  

iemStatusProbeMinHumidViolation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.14
The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'iemConfigProbeMinHumidThreshold' OID, and the value of the 'iemConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3).
OBJECT-TYPE    
  INTEGER noViolation(1), minHumidViolation(2), disabled(3)  

iemStatusProbeLocation 1.3.6.1.4.1.318.1.1.10.2.3.2.1.15
A descriptive location for the probe set by the user.
OBJECT-TYPE    
  DisplayString  

iemStatusContactsNumContacts 1.3.6.1.4.1.318.1.1.10.2.3.3
The number of contacts supported on the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

iemStatusContactsTable 1.3.6.1.4.1.318.1.1.10.2.3.4
A list of contacts supported by the Environmental Monitor and their status.
OBJECT-TYPE    
  SEQUENCE OF  
    IemStatusContactsEntry

iemStatusContactsEntry 1.3.6.1.4.1.318.1.1.10.2.3.4.1
The status of the contact.
OBJECT-TYPE    
  IemStatusContactsEntry  

iemStatusContactNumber 1.3.6.1.4.1.318.1.1.10.2.3.4.1.1
The index of the Environmental Monitor contact.
OBJECT-TYPE    
  INTEGER  

iemStatusContactName 1.3.6.1.4.1.318.1.1.10.2.3.4.1.2
A descriptive name for the Environmental Monitor contact set by the user, denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemStatusContactStatus 1.3.6.1.4.1.318.1.1.10.2.3.4.1.3
The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'iemConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'iemConfigContactEnable' OID is enabled. If the 'iemConfigContactEnable' OID is disabled, the status will show disabled(3).
OBJECT-TYPE    
  INTEGER noFault(1), fault(2), disabled(3)  

iemStatusRelaysNumRelays 1.3.6.1.4.1.318.1.1.10.2.3.6
The number of output relays supported on the Environmental Monitor.
OBJECT-TYPE    
  INTEGER  

iemStatusRelaysTable 1.3.6.1.4.1.318.1.1.10.2.3.7
A list of output relays supported by the Environmental Monitor and their status.
OBJECT-TYPE    
  SEQUENCE OF  
    IemStatusRelaysEntry

iemStatusRelaysEntry 1.3.6.1.4.1.318.1.1.10.2.3.7.1
The status of the relay.
OBJECT-TYPE    
  IemStatusRelaysEntry  

iemStatusRelayNumber 1.3.6.1.4.1.318.1.1.10.2.3.7.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

iemStatusRelayName 1.3.6.1.4.1.318.1.1.10.2.3.7.1.2
A descriptive name for the output relay set by the user, denoting its location or purpose.
OBJECT-TYPE    
  DisplayString  

iemStatusRelayStatus 1.3.6.1.4.1.318.1.1.10.2.3.7.1.3
The status of the output relay, either faultState(1) or normalState(2).
OBJECT-TYPE    
  INTEGER faultState(1), normalState(2)  

envMgtSystem 1.3.6.1.4.1.318.1.1.10.3
OBJECT IDENTIFIER    

emsIdent 1.3.6.1.4.1.318.1.1.10.3.1
OBJECT IDENTIFIER    

emsIdentEMSName 1.3.6.1.4.1.318.1.1.10.3.1.1
A character string identifying the device.
OBJECT-TYPE    
  DisplayString  

emsIdentProductNumber 1.3.6.1.4.1.318.1.1.10.3.1.2
A character string identifying the model number of the device. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

emsIdentFirmwareRev 1.3.6.1.4.1.318.1.1.10.3.1.3
The firmware revision of the device.
OBJECT-TYPE    
  DisplayString  

emsIdentHardwareRev 1.3.6.1.4.1.318.1.1.10.3.1.4
The hardware revision of the device. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

emsIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.10.3.1.5
The date when the device was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

emsIdentSerialNumber 1.3.6.1.4.1.318.1.1.10.3.1.6
A character string identifying the serial number of the device. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

emsOutputRelayControl 1.3.6.1.4.1.318.1.1.10.3.2
OBJECT IDENTIFIER    

emsOutputRelayControlTable 1.3.6.1.4.1.318.1.1.10.3.2.1
Allows for control of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EmsOutputRelayControlEntry

emsOutputRelayControlEntry 1.3.6.1.4.1.318.1.1.10.3.2.1.1
The output relays to control.
OBJECT-TYPE    
  EmsOutputRelayControlEntry  

emsOutputRelayControlOutputRelayIndex 1.3.6.1.4.1.318.1.1.10.3.2.1.1.1
The index to the output relay entry.
OBJECT-TYPE    
  INTEGER  

emsOutputRelayControlOutputRelayName 1.3.6.1.4.1.318.1.1.10.3.2.1.1.2
The name of the output relay. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

emsOutputRelayControlOutputRelayCommand 1.3.6.1.4.1.318.1.1.10.3.2.1.1.3
Getting this variable will return the output relay state. If the output relay is closed, the immediateCloseEMS (1) value will be returned. If the output relay is open, the immediateOpenEMS (2) value will be returned. Setting this variable to immediateCloseEMS (1) will immediately close the relay. Setting this variable to immediateOpenEMS (2) will immediately open the relay.
OBJECT-TYPE    
  INTEGER immediateCloseEMS(1), immediateOpenEMS(2)  

emsOutletControl 1.3.6.1.4.1.318.1.1.10.3.3
OBJECT IDENTIFIER    

emsOutletControlTable 1.3.6.1.4.1.318.1.1.10.3.3.1
Allows for control of individual outlet switches. The number of entries is contained in the emsStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EmsOutletControlEntry

emsOutletControlEntry 1.3.6.1.4.1.318.1.1.10.3.3.1.1
The outlets to control.
OBJECT-TYPE    
  EmsOutletControlEntry  

emsOutletControlOutletIndex 1.3.6.1.4.1.318.1.1.10.3.3.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

emsOutletControlOutletName 1.3.6.1.4.1.318.1.1.10.3.3.1.1.2
The name of the outlet. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

emsOutletControlOutletCommand 1.3.6.1.4.1.318.1.1.10.3.3.1.1.3
Getting this variable will return the outlet state. If the outlet is on, the immediateOnEMS (1) value will be returned. If the outlet is off, the immediateOffEMS (2) value will be returned. Setting this variable to immediateOnEMS (1) will immediately turn the outlet on. Setting this variable to immediateOffEMS (2) will immediately turn the outlet off.
OBJECT-TYPE    
  INTEGER immediateOnEMS(1), immediateOffEMS(2)  

emsSensorControl 1.3.6.1.4.1.318.1.1.10.3.4
OBJECT IDENTIFIER    

emsSensorControlTable 1.3.6.1.4.1.318.1.1.10.3.4.1
Allows for control/reset of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSSensorControlEntry

emsSensorControlEntry 1.3.6.1.4.1.318.1.1.10.3.4.1.1
The sensors to control/reset.
OBJECT-TYPE    
  EMSSensorControlEntry  

emsSensorControlSensorIndex 1.3.6.1.4.1.318.1.1.10.3.4.1.1.1
The index to the sensor entry.
OBJECT-TYPE    
  INTEGER  

emsSensorControlSensorSystemName 1.3.6.1.4.1.318.1.1.10.3.4.1.1.2
The system name of the sensor. This describes the hardware system intent of this sensor.
OBJECT-TYPE    
  DisplayString  

emsSensorControlSensorUserName 1.3.6.1.4.1.318.1.1.10.3.4.1.1.3
The name of the sensor as given by the system user.
OBJECT-TYPE    
  DisplayString  

emsSensorControlSensorCommand 1.3.6.1.4.1.318.1.1.10.3.4.1.1.4
Getting this variable will return noCommandEMS(1). Setting this variable to resetCommandEMS(2) will issue a reset command to the sensor. Some sensors cannot be manually reset and will not be affected by this command.
OBJECT-TYPE    
  INTEGER noCommandEMS(1), resetCommandEMS(2)  

emsAlarmDeviceControl 1.3.6.1.4.1.318.1.1.10.3.5
OBJECT IDENTIFIER    

emsAlarmDeviceControlTable 1.3.6.1.4.1.318.1.1.10.3.5.1
Allows for control of individual alarm devices. Note: Some alarm devices are not controllable. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EmsAlarmDeviceControlEntry

emsAlarmDeviceControlEntry 1.3.6.1.4.1.318.1.1.10.3.5.1.1
The alarm devices to control.
OBJECT-TYPE    
  EmsAlarmDeviceControlEntry  

emsAlarmDeviceControlDeviceIndex 1.3.6.1.4.1.318.1.1.10.3.5.1.1.1
The index to the alarm device entry.
OBJECT-TYPE    
  INTEGER  

emsAlarmDeviceControlDeviceName 1.3.6.1.4.1.318.1.1.10.3.5.1.1.2
The name of the alarm device. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

emsAlarmDeviceControlDeviceCommand 1.3.6.1.4.1.318.1.1.10.3.5.1.1.3
Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned. Actions resulting from setting this variable are device-dependent. Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on. Setting this variable to alarmDeviceOffEMS (2) will turn that device off.
OBJECT-TYPE    
  INTEGER alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)  

emsConfig 1.3.6.1.4.1.318.1.1.10.3.6
OBJECT IDENTIFIER    

emsConfigName 1.3.6.1.4.1.318.1.1.10.3.6.1
The name of the device.
OBJECT-TYPE    
  DisplayString  

emsConfigCheckLogLight 1.3.6.1.4.1.318.1.1.10.3.6.2
The setting of this OID determines the level of event that will trigger the check-log light on the EMS. This is not available on the EMU2. lightDisabled (1) disables the check-log light. lightOnInformational (2) lights check-log for any event of informational severity or above. lightOnWarning (3) lights check-log for any event of warning severity or above. lightOnSevere (4) lights check-log for any event of severe severity.
OBJECT-TYPE    
  INTEGER lightDisabled(1), lightOnInformational(2), lightOnWarning(3), lightOnSevere(4)  

emsProbeConfig 1.3.6.1.4.1.318.1.1.10.3.7
OBJECT IDENTIFIER    

emsProbeConfigTable 1.3.6.1.4.1.318.1.1.10.3.7.1
Allows for configuration of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSProbeConfigEntry

emsProbeConfigEntry 1.3.6.1.4.1.318.1.1.10.3.7.1.1
The probes to configure.
OBJECT-TYPE    
  EMSProbeConfigEntry  

emsProbeConfigProbeIndex 1.3.6.1.4.1.318.1.1.10.3.7.1.1.1
The index to the probe entry.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeName 1.3.6.1.4.1.318.1.1.10.3.7.1.1.2
The name of the probe.
OBJECT-TYPE    
  DisplayString  

emsProbeConfigProbeHighTempThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.3
Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLowTempThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.4
Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeHighHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.5
Probe high humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLowHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.6
Probe low humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeMaxTempThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.7
Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeMinTempThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.8
Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeDeltaTemp 1.3.6.1.4.1.318.1.1.10.3.7.1.1.9
Probe delta temperature. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeMaxHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.10
Probe maximum humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeMinHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.7.1.1.11
Probe minimum humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeDeltaHumidity 1.3.6.1.4.1.318.1.1.10.3.7.1.1.12
Probe delta humidity. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeSTIncTempVariance 1.3.6.1.4.1.318.1.1.10.3.7.1.1.13
Probe short-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeSTIncTempTime 1.3.6.1.4.1.318.1.1.10.3.7.1.1.14
Probe short-term increasing temperature time used for rate of change alarms. Values are represented in whole number minutes.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeSTDecTempVariance 1.3.6.1.4.1.318.1.1.10.3.7.1.1.15
Probe short-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeSTDecTempTime 1.3.6.1.4.1.318.1.1.10.3.7.1.1.16
Probe short-term decreasing temperature time used for rate of change alarms. Values are represented in whole number minutes.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLTIncTempVariance 1.3.6.1.4.1.318.1.1.10.3.7.1.1.17
Probe long-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLTIncTempTime 1.3.6.1.4.1.318.1.1.10.3.7.1.1.18
Probe long-term increasing temperature time used for rate of change alarms. Values are represented in whole number hours.
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLTDecTempVariance 1.3.6.1.4.1.318.1.1.10.3.7.1.1.19
Probe long-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeConfigProbeLTDecTempTime 1.3.6.1.4.1.318.1.1.10.3.7.1.1.20
Probe long-term decreasing temperature time used for rate of change alarms. Values are represented in whole number hours.
OBJECT-TYPE    
  INTEGER  

emsInputContactConfig 1.3.6.1.4.1.318.1.1.10.3.8
OBJECT IDENTIFIER    

emsInputContactConfigTable 1.3.6.1.4.1.318.1.1.10.3.8.1
Allows for configuration of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSInputContactConfigEntry

emsInputContactConfigEntry 1.3.6.1.4.1.318.1.1.10.3.8.1.1
The input contacts to configure.
OBJECT-TYPE    
  EMSInputContactConfigEntry  

emsInputContactConfigInputContactIndex 1.3.6.1.4.1.318.1.1.10.3.8.1.1.1
The index to the input contact entry.
OBJECT-TYPE    
  INTEGER  

emsInputContactConfigInputContactName 1.3.6.1.4.1.318.1.1.10.3.8.1.1.2
The name of the input contact.
OBJECT-TYPE    
  DisplayString  

emsInputContactConfigInputContactNormalState 1.3.6.1.4.1.318.1.1.10.3.8.1.1.3
Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the input contact
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsOutputRelayConfig 1.3.6.1.4.1.318.1.1.10.3.9
OBJECT IDENTIFIER    

emsOutputRelayConfigTable 1.3.6.1.4.1.318.1.1.10.3.9.1
Allows for configuration of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSOutputRelayConfigEntry

emsOutputRelayConfigEntry 1.3.6.1.4.1.318.1.1.10.3.9.1.1
The output relays to configure.
OBJECT-TYPE    
  EMSOutputRelayConfigEntry  

emsOutputRelayConfigOutputRelayIndex 1.3.6.1.4.1.318.1.1.10.3.9.1.1.1
The index to the output relay entry.
OBJECT-TYPE    
  INTEGER  

emsOutputRelayConfigOutputRelayName 1.3.6.1.4.1.318.1.1.10.3.9.1.1.2
The name of the output relay.
OBJECT-TYPE    
  DisplayString  

emsOutputRelayConfigOutputRelayNormalState 1.3.6.1.4.1.318.1.1.10.3.9.1.1.3
Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the output relay
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsOutletConfig 1.3.6.1.4.1.318.1.1.10.3.10
OBJECT IDENTIFIER    

emsOutletConfigTable 1.3.6.1.4.1.318.1.1.10.3.10.1
Allows for configuration of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSOutletConfigEntry

emsOutletConfigEntry 1.3.6.1.4.1.318.1.1.10.3.10.1.1
The outlets to configure.
OBJECT-TYPE    
  EMSOutletConfigEntry  

emsOutletConfigOutletIndex 1.3.6.1.4.1.318.1.1.10.3.10.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

emsOutletConfigOutletName 1.3.6.1.4.1.318.1.1.10.3.10.1.1.2
The name of the outlet.
OBJECT-TYPE    
  DisplayString  

emsOutletConfigOutletNormalState 1.3.6.1.4.1.318.1.1.10.3.10.1.1.3
Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. Setting this variable will change the normal state of the outlet
OBJECT-TYPE    
  INTEGER normallyOnEMS(1), normallyOffEMS(2)  

emsSensorConfig 1.3.6.1.4.1.318.1.1.10.3.11
OBJECT IDENTIFIER    

emsSensorConfigTable 1.3.6.1.4.1.318.1.1.10.3.11.1
Allows for configuration of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSSensorConfigEntry

emsSensorConfigEntry 1.3.6.1.4.1.318.1.1.10.3.11.1.1
The sensors to configure.
OBJECT-TYPE    
  EMSSensorConfigEntry  

emsSensorConfigSensorIndex 1.3.6.1.4.1.318.1.1.10.3.11.1.1.1
The index to the sensor entry.
OBJECT-TYPE    
  INTEGER  

emsSensorConfigSensorSystemName 1.3.6.1.4.1.318.1.1.10.3.11.1.1.2
The system name of the sensor. This describes the hardware system intent of this sensor.
OBJECT-TYPE    
  DisplayString  

emsSensorConfigSensorUserName 1.3.6.1.4.1.318.1.1.10.3.11.1.1.3
The name of the sensor as given by the system user.
OBJECT-TYPE    
  DisplayString  

emsSensorConfigSensorNormalState 1.3.6.1.4.1.318.1.1.10.3.11.1.1.4
Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the sensor. Note: Only the AUX sensor in the EMS has a configurable Normal State
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsSensorConfigSensorAlarmDelay 1.3.6.1.4.1.318.1.1.10.3.11.1.1.5
The delay (in seconds) after a sensor detects an alarm condition before the condition is reported.
OBJECT-TYPE    
  INTEGER  

emsStatus 1.3.6.1.4.1.318.1.1.10.3.12
OBJECT IDENTIFIER    

emsStatusEMSName 1.3.6.1.4.1.318.1.1.10.3.12.1
A character string identifying the device.
OBJECT-TYPE    
  DisplayString  

emsStatusCommStatus 1.3.6.1.4.1.318.1.1.10.3.12.2
The communication status between the agent and the device. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost.
OBJECT-TYPE    
  INTEGER noComm(1), comm(2), commLost(3)  

emsStatusProbeCount 1.3.6.1.4.1.318.1.1.10.3.12.3
The total number of T/H probes (both local and remote) that is supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusInputContactCount 1.3.6.1.4.1.318.1.1.10.3.12.4
The total number of Input Contacts that is supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusOutputRelayCount 1.3.6.1.4.1.318.1.1.10.3.12.5
The total number of Output Relays that is supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusOutletCount 1.3.6.1.4.1.318.1.1.10.3.12.6
The total number of AC Outlets that is supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusSensorCount 1.3.6.1.4.1.318.1.1.10.3.12.7
The total number of Sensors that is supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusAlinkAruDeviceCount 1.3.6.1.4.1.318.1.1.10.3.12.8
The total number of remote Aru's supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusAlinkProbeDeviceCount 1.3.6.1.4.1.318.1.1.10.3.12.9
The total number of remote T/H probes supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusAlarmDeviceCount 1.3.6.1.4.1.318.1.1.10.3.12.10
The number of alarm devices supported by this device.
OBJECT-TYPE    
  INTEGER  

emsStatusSysTempUnits 1.3.6.1.4.1.318.1.1.10.3.12.11
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

emsStatusCheckLogLight 1.3.6.1.4.1.318.1.1.10.3.12.12
The status of the check-log light on the device. For the EMU2, this will always indicate lightOff(1). lightOff (1) indicates the light is off (no new log entries). lightOn (2) indicates the light is on (new log entries present).
OBJECT-TYPE    
  INTEGER lightOff(1), lightOn(2)  

emsStatusHardwareStatus 1.3.6.1.4.1.318.1.1.10.3.12.13
The status of the EMS hardware. This integer should be interpreted as a bit map, with each bit representing the presence or absence of a specific hardware error condition. 0 indicates there are no error conditions detected in the EMS hardware. 1 indicates a Current Limit error condition related to the Alink port. 2 indicates incorrect hardware is plugged into an EMS port. 3 indicates that both of these error conditions are present.
OBJECT-TYPE    
  INTEGER  

emsProbeStatus 1.3.6.1.4.1.318.1.1.10.3.13
OBJECT IDENTIFIER    

emsProbeStatusTable 1.3.6.1.4.1.318.1.1.10.3.13.1
Allows for access of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSProbeStatusEntry

emsProbeStatusEntry 1.3.6.1.4.1.318.1.1.10.3.13.1.1
The probes to access.
OBJECT-TYPE    
  EMSProbeStatusEntry  

emsProbeStatusProbeIndex 1.3.6.1.4.1.318.1.1.10.3.13.1.1.1
The index to the probe entry.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeName 1.3.6.1.4.1.318.1.1.10.3.13.1.1.2
The name of the probe.
OBJECT-TYPE    
  DisplayString  

emsProbeStatusProbeTemperature 1.3.6.1.4.1.318.1.1.10.3.13.1.1.3
Probe temperature reading. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeHighTempThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.4
Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeLowTempThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.5
Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeHumidity 1.3.6.1.4.1.318.1.1.10.3.13.1.1.6
Probe humidity reading. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeHighHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.7
Probe high humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeLowHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.8
Probe low humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeSerialNumber 1.3.6.1.4.1.318.1.1.10.3.13.1.1.9
A label indicating the type (Local[L] or Remote[R]) and Number of the probe. For example, the first local probe would be L1 and the third remote probe would be R3.
OBJECT-TYPE    
  DisplayString  

emsProbeStatusProbeCommStatus 1.3.6.1.4.1.318.1.1.10.3.13.1.1.10
The state of communications to the probe. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no longer.
OBJECT-TYPE    
  INTEGER commsNeverDiscovered(1), commsEstablished(2), commsLost(3)  

emsProbeStatusProbeAlarmStatus 1.3.6.1.4.1.318.1.1.10.3.13.1.1.11
The alarm status of the probe. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded. 6 0x0020 Short-term decreasing temperature rate exceeded. 7 0x0040 Long-term increasing temperature rate exceeded. 8 0x0080 Long-term decreasing temperature rate exceeded. 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeMaxTempThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.12
Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeMinTempThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.13
Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeMaxHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.14
Probe maximum humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsProbeStatusProbeMinHumidityThresh 1.3.6.1.4.1.318.1.1.10.3.13.1.1.15
Probe minimum humidity threshold. Values are represented in whole number percentage.
OBJECT-TYPE    
  INTEGER  

emsInputContactStatus 1.3.6.1.4.1.318.1.1.10.3.14
OBJECT IDENTIFIER    

emsInputContactStatusTable 1.3.6.1.4.1.318.1.1.10.3.14.1
Allows for access of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSInputContactStatusEntry

emsInputContactStatusEntry 1.3.6.1.4.1.318.1.1.10.3.14.1.1
The input contacts to access.
OBJECT-TYPE    
  EMSInputContactStatusEntry  

emsInputContactStatusInputContactIndex 1.3.6.1.4.1.318.1.1.10.3.14.1.1.1
The index to the input contact entry.
OBJECT-TYPE    
  INTEGER  

emsInputContactStatusInputContactName 1.3.6.1.4.1.318.1.1.10.3.14.1.1.2
The name of the input contact.
OBJECT-TYPE    
  DisplayString  

emsInputContactStatusInputContactState 1.3.6.1.4.1.318.1.1.10.3.14.1.1.3
Getting this variable will return the state of the input contact. If the input contact is closed, the contactClosedEMS (1) value will be returned. If the input contact state is open, the contactOpenEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER contactClosedEMS(1), contactOpenEMS(2)  

emsInputContactStatusInputContactNormalState 1.3.6.1.4.1.318.1.1.10.3.14.1.1.4
Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsOutputRelayStatus 1.3.6.1.4.1.318.1.1.10.3.15
OBJECT IDENTIFIER    

emsOutputRelayStatusTable 1.3.6.1.4.1.318.1.1.10.3.15.1
Allows for access of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSOutputRelayStatusEntry

emsOutputRelayStatusEntry 1.3.6.1.4.1.318.1.1.10.3.15.1.1
The output relays to access.
OBJECT-TYPE    
  EMSOutputRelayStatusEntry  

emsOutputRelayStatusOutputRelayIndex 1.3.6.1.4.1.318.1.1.10.3.15.1.1.1
The index to the output relay entry.
OBJECT-TYPE    
  INTEGER  

emsOutputRelayStatusOutputRelayName 1.3.6.1.4.1.318.1.1.10.3.15.1.1.2
The name of the output relay.
OBJECT-TYPE    
  DisplayString  

emsOutputRelayStatusOutputRelayState 1.3.6.1.4.1.318.1.1.10.3.15.1.1.3
Getting this variable will return the state of the output relay. If the output relay is closed, the relayClosedEMS (1) value will be returned. If the output relay is open, the relayOpenEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER relayClosedEMS(1), relayOpenEMS(2)  

emsOutputRelayStatusOutputRelayNormalState 1.3.6.1.4.1.318.1.1.10.3.15.1.1.4
Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsOutletStatus 1.3.6.1.4.1.318.1.1.10.3.16
OBJECT IDENTIFIER    

emsOutletStatusTable 1.3.6.1.4.1.318.1.1.10.3.16.1
Allows for access of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSOutletStatusEntry

emsOutletStatusEntry 1.3.6.1.4.1.318.1.1.10.3.16.1.1
The outlets to access.
OBJECT-TYPE    
  EMSOutletStatusEntry  

emsOutletStatusOutletIndex 1.3.6.1.4.1.318.1.1.10.3.16.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

emsOutletStatusOutletName 1.3.6.1.4.1.318.1.1.10.3.16.1.1.2
The name of the outlet.
OBJECT-TYPE    
  DisplayString  

emsOutletStatusOutletState 1.3.6.1.4.1.318.1.1.10.3.16.1.1.3
Getting this variable will return the state of the outlet. If the outlet is on, the outletOnEMS (1) value will be returned. If the outlet is off, the outletOffEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER outletOnEMS(1), outletOffEMS(2)  

emsOutletStatusOutletNormalState 1.3.6.1.4.1.318.1.1.10.3.16.1.1.4
Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER normallyOnEMS(1), normallyOffEMS(2)  

emsAlarmDeviceStatus 1.3.6.1.4.1.318.1.1.10.3.17
OBJECT IDENTIFIER    

emsAlarmDeviceStatusTable 1.3.6.1.4.1.318.1.1.10.3.17.1
Allows for access of individual alarm devices. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSAlarmDeviceStatusEntry

emsAlarmDeviceStatusEntry 1.3.6.1.4.1.318.1.1.10.3.17.1.1
The alarm devices to access.
OBJECT-TYPE    
  EMSAlarmDeviceStatusEntry  

emsAlarmDeviceStatusDeviceIndex 1.3.6.1.4.1.318.1.1.10.3.17.1.1.1
The index to the alarm device entry.
OBJECT-TYPE    
  INTEGER  

emsAlarmDeviceStatusDeviceName 1.3.6.1.4.1.318.1.1.10.3.17.1.1.2
The name of the alarm device. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

emsAlarmDeviceStatusDeviceState 1.3.6.1.4.1.318.1.1.10.3.17.1.1.3
Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned.
OBJECT-TYPE    
  INTEGER alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)  

emsSensorStatus 1.3.6.1.4.1.318.1.1.10.3.18
OBJECT IDENTIFIER    

emsSensorStatusTable 1.3.6.1.4.1.318.1.1.10.3.18.1
Allows for access of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    EMSSensorStatusEntry

emsSensorStatusEntry 1.3.6.1.4.1.318.1.1.10.3.18.1.1
The sensors to access.
OBJECT-TYPE    
  EMSSensorStatusEntry  

emsSensorStatusSensorIndex 1.3.6.1.4.1.318.1.1.10.3.18.1.1.1
The index to the sensor entry.
OBJECT-TYPE    
  INTEGER  

emsSensorStatusSensorSystemName 1.3.6.1.4.1.318.1.1.10.3.18.1.1.2
The system name of the sensor. This describes the hardware system intent of this sensor.
OBJECT-TYPE    
  DisplayString  

emsSensorStatusSensorName 1.3.6.1.4.1.318.1.1.10.3.18.1.1.3
The name of the sensor as given by the system user.
OBJECT-TYPE    
  DisplayString  

emsSensorStatusSensorState 1.3.6.1.4.1.318.1.1.10.3.18.1.1.4
Getting this variable will return the sensor state. If the sensor is faulted, the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, the sensorOKEMS (2) value will be returned. If the sensor is not installed, the sensorNotInstalledEMS (3) value will be returned.
OBJECT-TYPE    
  INTEGER sensorFaultedEMS(1), sensorOKEMS(2), sensorNotInstalledEMS(3)  

emsSensorStatusSensorNormalState 1.3.6.1.4.1.318.1.1.10.3.18.1.1.5
Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned.
OBJECT-TYPE    
  INTEGER normallyClosedEMS(1), normallyOpenEMS(2)  

emsSensorStatusSensorAlarmDelay 1.3.6.1.4.1.318.1.1.10.3.18.1.1.6
The delay (in seconds) after a sensor detects an alarm condition before the condition is reported.
OBJECT-TYPE    
  INTEGER  

modEnvMgr 1.3.6.1.4.1.318.1.1.10.4
OBJECT IDENTIFIER    

memModules 1.3.6.1.4.1.318.1.1.10.4.1
OBJECT IDENTIFIER    

memModulesStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.1.1
The number of entries in the memModulesStatusTable.
OBJECT-TYPE    
  INTEGER  

memModulesStatusTable 1.3.6.1.4.1.318.1.1.10.4.1.2
Allows for getting status information from the modules attached to the system.
OBJECT-TYPE    
  SEQUENCE OF  
    MemModulesStatusEntry

memModulesStatusEntry 1.3.6.1.4.1.318.1.1.10.4.1.2.1
The unit to get data from.
OBJECT-TYPE    
  MemModulesStatusEntry  

memModulesStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.1.2.1.1
The module number.
OBJECT-TYPE    
  INTEGER  

memModulesStatusModuleName 1.3.6.1.4.1.318.1.1.10.4.1.2.1.2
The module name.
OBJECT-TYPE    
  DisplayString  

memModulesStatusModuleLocation 1.3.6.1.4.1.318.1.1.10.4.1.2.1.3
The location of the module.
OBJECT-TYPE    
  DisplayString  

memModulesStatusModelNumber 1.3.6.1.4.1.318.1.1.10.4.1.2.1.4
The model number of the module.
OBJECT-TYPE    
  DisplayString  

memModulesStatusSerialNumber 1.3.6.1.4.1.318.1.1.10.4.1.2.1.5
The serial number of the module.
OBJECT-TYPE    
  DisplayString  

memModulesStatusFirmwareRev 1.3.6.1.4.1.318.1.1.10.4.1.2.1.6
The firmware revision of the module.
OBJECT-TYPE    
  DisplayString  

memModulesStatusHardwareRev 1.3.6.1.4.1.318.1.1.10.4.1.2.1.7
The hardware revision.
OBJECT-TYPE    
  DisplayString  

memModulesConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.1.3
The number of entries in the memModulesConfigTable.
OBJECT-TYPE    
  INTEGER  

memModulesConfigTable 1.3.6.1.4.1.318.1.1.10.4.1.4
Allows for getting status information from the modules attached to the system.
OBJECT-TYPE    
  SEQUENCE OF  
    MemModulesConfigEntry

memModulesConfigEntry 1.3.6.1.4.1.318.1.1.10.4.1.4.1
The unit to get data from.
OBJECT-TYPE    
  MemModulesConfigEntry  

memModulesConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.1.4.1.1
The module number.
OBJECT-TYPE    
  INTEGER  

memModulesConfigModuleName 1.3.6.1.4.1.318.1.1.10.4.1.4.1.2
The module name.
OBJECT-TYPE    
  DisplayString  

memModulesConfigModuleLocation 1.3.6.1.4.1.318.1.1.10.4.1.4.1.3
The location of the module.
OBJECT-TYPE    
  DisplayString  

memSensors 1.3.6.1.4.1.318.1.1.10.4.2
OBJECT IDENTIFIER    

memSensorsStatusSysTempUnits 1.3.6.1.4.1.318.1.1.10.4.2.1
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

memSensorsStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.2.2
The number of entries in the memSensorsStatusTable.
OBJECT-TYPE    
  INTEGER  

memSensorsStatusTable 1.3.6.1.4.1.318.1.1.10.4.2.3
Allows for getting sensor status information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemSensorsStatusEntry

memSensorsStatusEntry 1.3.6.1.4.1.318.1.1.10.4.2.3.1
The unit to get data from.
OBJECT-TYPE    
  MemSensorsStatusEntry  

memSensorsStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.2.3.1.1
The number of the module that the sensor is attached to.
OBJECT-TYPE    
  INTEGER  

memSensorsStatusSensorNumber 1.3.6.1.4.1.318.1.1.10.4.2.3.1.2
The number of this sensor on the module.
OBJECT-TYPE    
  INTEGER  

memSensorsStatusSensorName 1.3.6.1.4.1.318.1.1.10.4.2.3.1.3
The sensor name.
OBJECT-TYPE    
  DisplayString  

memSensorsStatusSensorLocation 1.3.6.1.4.1.318.1.1.10.4.2.3.1.4
The location of the sensor.
OBJECT-TYPE    
  DisplayString  

memSensorsTemperature 1.3.6.1.4.1.318.1.1.10.4.2.3.1.5
The sensor's current temperature reading. Units are displayed in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

memSensorsHumidity 1.3.6.1.4.1.318.1.1.10.4.2.3.1.6
The current humidity reading from the sensor.
OBJECT-TYPE    
  INTEGER  

memSensorsCommStatus 1.3.6.1.4.1.318.1.1.10.4.2.3.1.7
The communications status of the sensor.
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

memSensorsAlarmStatus 1.3.6.1.4.1.318.1.1.10.4.2.3.1.8
The alarm status of the sensor.
OBJECT-TYPE    
  INTEGER memNormal(1), memWarning(2), memCritical(3)  

memSensorsConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.2.4
The number of entries in the memSensorsConfigTable.
OBJECT-TYPE    
  INTEGER  

memSensorsConfigTable 1.3.6.1.4.1.318.1.1.10.4.2.5
Allows for getting configuration information from sensors attached to the system.
OBJECT-TYPE    
  SEQUENCE OF  
    MemSensorsConfigEntry

memSensorsConfigEntry 1.3.6.1.4.1.318.1.1.10.4.2.5.1
The unit to get data from.
OBJECT-TYPE    
  MemSensorsConfigEntry  

memSensorsConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.2.5.1.1
The number of the module that the sensor is attached to.
OBJECT-TYPE    
  INTEGER  

memSensorsConfigSensorNumber 1.3.6.1.4.1.318.1.1.10.4.2.5.1.2
The number of this sensor on the module.
OBJECT-TYPE    
  INTEGER  

memSensorsName 1.3.6.1.4.1.318.1.1.10.4.2.5.1.3
A descriptive name for the sensor.
OBJECT-TYPE    
  DisplayString  

memSensorsLocation 1.3.6.1.4.1.318.1.1.10.4.2.5.1.4
The location of the sensor.
OBJECT-TYPE    
  DisplayString  

memSensorsAlarmGeneration 1.3.6.1.4.1.318.1.1.10.4.2.5.1.5
Enable or disable alarm generation on this sensor.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

memSensorsTempMaxThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.6
The temperature at which the MEM will generate a maximum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempHighThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.7
The temperature at which the MEM will generate a high temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempLowThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.8
The temperature at which the MEM will generate a low temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempMinThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.9
The temperature at which the MEM will generate a minimum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempThreshHysteresis 1.3.6.1.4.1.318.1.1.10.4.2.5.1.10
The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempShortDecRateThreshValue 1.3.6.1.4.1.318.1.1.10.4.2.5.1.11
The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempShortDecRateThreshTime 1.3.6.1.4.1.318.1.1.10.4.2.5.1.12
The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

memSensorsTempShortIncRateThreshValue 1.3.6.1.4.1.318.1.1.10.4.2.5.1.13
The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempShortIncRateThreshTime 1.3.6.1.4.1.318.1.1.10.4.2.5.1.14
The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

memSensorsTempLongDecRateThreshValue 1.3.6.1.4.1.318.1.1.10.4.2.5.1.15
The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempLongDecRateThreshTime 1.3.6.1.4.1.318.1.1.10.4.2.5.1.16
The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

memSensorsTempLongIncRateThreshValue 1.3.6.1.4.1.318.1.1.10.4.2.5.1.17
The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
OBJECT-TYPE    
  INTEGER  

memSensorsTempLongIncRateThreshTime 1.3.6.1.4.1.318.1.1.10.4.2.5.1.18
The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

memSensorsHumidityMaxThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.19
The humidity at which the maximum humidity threshold alarm will be generated.
OBJECT-TYPE    
  INTEGER  

memSensorsHumidityHighThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.20
The humidity at which the high humidity threshold alarm will be generated.
OBJECT-TYPE    
  INTEGER  

memSensorsHumidityLowThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.21
The humidity at which the low humidity threshold alarm will be generated.
OBJECT-TYPE    
  INTEGER  

memSensorsHumidityMinThresh 1.3.6.1.4.1.318.1.1.10.4.2.5.1.22
The humidity at which the minimum humidity threshold alarm will be generated.
OBJECT-TYPE    
  INTEGER  

memSensorsHumidityThreshHysteresis 1.3.6.1.4.1.318.1.1.10.4.2.5.1.23
The change in humidity required to cause an active humidity alarm to change to the inactive state.
OBJECT-TYPE    
  INTEGER  

memInputs 1.3.6.1.4.1.318.1.1.10.4.3
OBJECT IDENTIFIER    

memInputsStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.3.1
The number of entries in the memInputsStatusTable.
OBJECT-TYPE    
  INTEGER  

memInputsStatusTable 1.3.6.1.4.1.318.1.1.10.4.3.2
Allows for getting input status information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemInputsStatusEntry

memInputsStatusEntry 1.3.6.1.4.1.318.1.1.10.4.3.2.1
The unit to get data from.
OBJECT-TYPE    
  MemInputsStatusEntry  

memInputsStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.3.2.1.1
The number of the module that the input is attached to.
OBJECT-TYPE    
  INTEGER  

memInputsStatusInputNumber 1.3.6.1.4.1.318.1.1.10.4.3.2.1.2
The number of this input on the module.
OBJECT-TYPE    
  INTEGER  

memInputsStatusInputName 1.3.6.1.4.1.318.1.1.10.4.3.2.1.3
The input name.
OBJECT-TYPE    
  DisplayString  

memInputsStatusInputLocation 1.3.6.1.4.1.318.1.1.10.4.3.2.1.4
The location of the input.
OBJECT-TYPE    
  DisplayString  

memInputsStatusCurrentState 1.3.6.1.4.1.318.1.1.10.4.3.2.1.5
The current state of the input. This OID will return inputStateNotAplicable(4) for analog input types.
OBJECT-TYPE    
  INTEGER inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)  

memInputsStatusCurrentAnalogValue 1.3.6.1.4.1.318.1.1.10.4.3.2.1.6
The current analog value of the input in the units defined by the user.
OBJECT-TYPE    
  DisplayString  

memInputsStatusAlarmStatus 1.3.6.1.4.1.318.1.1.10.4.3.2.1.7
The alarm status of the input.
OBJECT-TYPE    
  INTEGER memNormal(1), memWarning(2), memCritical(3)  

memInputsCommStatus 1.3.6.1.4.1.318.1.1.10.4.3.2.1.8
The communications status of the input. This OID is only supported by NBRK0200.
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

memInputsConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.3.3
The number of entries in the memInputsConfigTable.
OBJECT-TYPE    
  INTEGER  

memInputsConfigTable 1.3.6.1.4.1.318.1.1.10.4.3.4
Allows for getting input configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemInputsConfigEntry

memInputsConfigEntry 1.3.6.1.4.1.318.1.1.10.4.3.4.1
The unit to get data from.
OBJECT-TYPE    
  MemInputsConfigEntry  

memInputsConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.3.4.1.1
The number of the module that the input is attached to.
OBJECT-TYPE    
  INTEGER  

memInputsConfigInputNumber 1.3.6.1.4.1.318.1.1.10.4.3.4.1.2
The number of this input on the module.
OBJECT-TYPE    
  INTEGER  

memInputName 1.3.6.1.4.1.318.1.1.10.4.3.4.1.3
The name of the input.
OBJECT-TYPE    
  DisplayString  

memInputLocation 1.3.6.1.4.1.318.1.1.10.4.3.4.1.4
The location of the input.
OBJECT-TYPE    
  DisplayString  

memInputType 1.3.6.1.4.1.318.1.1.10.4.3.4.1.5
The type of input this contact will take.
OBJECT-TYPE    
  INTEGER noConnection(1), dryContact(2), digital(3), analogmAmps(4), analogVolts(5)  

memInputAlarmGeneration 1.3.6.1.4.1.318.1.1.10.4.3.4.1.6
Enable or disable alarm generation on this input.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

memInputNormalState 1.3.6.1.4.1.318.1.1.10.4.3.4.1.7
Defines the normal (no alarm) state of the input.
OBJECT-TYPE    
  INTEGER inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)  

memInputAbnormalSeverity 1.3.6.1.4.1.318.1.1.10.4.3.4.1.8
Defines the severity of the event that is associated with the abnormal state of the input. This OID will return inputSeverityNotApplicable(4) for analog input types.
OBJECT-TYPE    
  INTEGER inputSeverityinformational(1), inputSeveritywarning(2), inputSeveritysevere(3), inputSeverityNotApplicable(4)  

memInputNumberCalibrationPoints 1.3.6.1.4.1.318.1.1.10.4.3.4.1.9
The number of calibration points that are required for this input.
OBJECT-TYPE    
  INTEGER  

memInputAnalogCalibrationPoint1 1.3.6.1.4.1.318.1.1.10.4.3.4.1.10
The electrical value that the input sensor will measure at the first calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint2 1.3.6.1.4.1.318.1.1.10.4.3.4.1.11
The electrical value that the input sensor will measure at the second calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint3 1.3.6.1.4.1.318.1.1.10.4.3.4.1.12
The electrical value that the input sensor will measure at the third calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint4 1.3.6.1.4.1.318.1.1.10.4.3.4.1.13
The electrical value that the input sensor will measure at the fourth calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint5 1.3.6.1.4.1.318.1.1.10.4.3.4.1.14
The electrical value that the input sensor will measure at the fifth calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint1Value 1.3.6.1.4.1.318.1.1.10.4.3.4.1.15
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the first calibration point.
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint2Value 1.3.6.1.4.1.318.1.1.10.4.3.4.1.16
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the second calibration point.
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint3Value 1.3.6.1.4.1.318.1.1.10.4.3.4.1.17
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the third calibration point.
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint4Value 1.3.6.1.4.1.318.1.1.10.4.3.4.1.18
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fourth calibration point.
OBJECT-TYPE    
  DisplayString  

memInputAnalogCalibrationPoint5Value 1.3.6.1.4.1.318.1.1.10.4.3.4.1.19
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fifth calibration point.
OBJECT-TYPE    
  DisplayString  

memInputAnalogMeasurementUnits 1.3.6.1.4.1.318.1.1.10.4.3.4.1.20
The units of measure to be used for this input.
OBJECT-TYPE    
  DisplayString  

memInputAnalogMaxThresh 1.3.6.1.4.1.318.1.1.10.4.3.4.1.21
The input value at which a maximum threshold violation alarm will be generated on this input.
OBJECT-TYPE    
  DisplayString  

memInputAnalogHighThresh 1.3.6.1.4.1.318.1.1.10.4.3.4.1.22
The input value at which a high threshold violation alarm will be generated on this input.
OBJECT-TYPE    
  DisplayString  

memInputAnalogLowThresh 1.3.6.1.4.1.318.1.1.10.4.3.4.1.23
The input value at which a low threshold violation alarm will be generated on this input.
OBJECT-TYPE    
  DisplayString  

memInputAnalogMinThresh 1.3.6.1.4.1.318.1.1.10.4.3.4.1.24
The input value at which a minimum threshold violation alarm will be generated on this input.
OBJECT-TYPE    
  DisplayString  

memInputAnalogThreshHysteresis 1.3.6.1.4.1.318.1.1.10.4.3.4.1.25
The change in value required to cause an alarm on this input to change from active to inactive.
OBJECT-TYPE    
  DisplayString  

memOutputs 1.3.6.1.4.1.318.1.1.10.4.4
OBJECT IDENTIFIER    

memOutputStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.4.1
The number of entries in the memOutputStatusTable.
OBJECT-TYPE    
  INTEGER  

memOutputStatusTable 1.3.6.1.4.1.318.1.1.10.4.4.2
Allows for getting output status information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemOutputStatusEntry

memOutputStatusEntry 1.3.6.1.4.1.318.1.1.10.4.4.2.1
The unit to get data from.
OBJECT-TYPE    
  MemOutputStatusEntry  

memOutputStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.4.2.1.1
The number of the module that the output is attached to.
OBJECT-TYPE    
  INTEGER  

memOutputStatusOutputNumber 1.3.6.1.4.1.318.1.1.10.4.4.2.1.2
The number of this output on the module.
OBJECT-TYPE    
  INTEGER  

memOutputStatusOutputName 1.3.6.1.4.1.318.1.1.10.4.4.2.1.3
The output name.
OBJECT-TYPE    
  DisplayString  

memOutputStatusOutputLocation 1.3.6.1.4.1.318.1.1.10.4.4.2.1.4
The location of the output.
OBJECT-TYPE    
  DisplayString  

memOutputStatusCurrentState 1.3.6.1.4.1.318.1.1.10.4.4.2.1.5
The state of the output.
OBJECT-TYPE    
  INTEGER memOutputClosed(1), memOutputOpen(2)  

memOutputConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.4.3
The number of entries in the memOutputConfigTable.
OBJECT-TYPE    
  INTEGER  

memOutputConfigTable 1.3.6.1.4.1.318.1.1.10.4.4.4
Allows for getting output configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemOutputConfigEntry

memOutputConfigEntry 1.3.6.1.4.1.318.1.1.10.4.4.4.1
The unit to get data from.
OBJECT-TYPE    
  MemOutputConfigEntry  

memOutputConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.4.4.1.1
The number of the module that the output is attached to.
OBJECT-TYPE    
  INTEGER  

memOutputConfigOutputNumber 1.3.6.1.4.1.318.1.1.10.4.4.4.1.2
The number of this output on the module.
OBJECT-TYPE    
  INTEGER  

memOutputName 1.3.6.1.4.1.318.1.1.10.4.4.4.1.3
The name of the output.
OBJECT-TYPE    
  DisplayString  

memOutputLocation 1.3.6.1.4.1.318.1.1.10.4.4.4.1.4
The location of the output.
OBJECT-TYPE    
  DisplayString  

memOutputNormalState 1.3.6.1.4.1.318.1.1.10.4.4.4.1.5
The state of the output that will not generate an alarm.
OBJECT-TYPE    
  INTEGER memOutputClosed(1), memOutputOpen(2)  

memOutputAction 1.3.6.1.4.1.318.1.1.10.4.4.4.1.6
Manual control actions for the output. SNMP get command will return the state of the output, SNMP set of this OID controls the output.
OBJECT-TYPE    
  INTEGER memActionClose(1), memActionOpen(2)  

memOutlets 1.3.6.1.4.1.318.1.1.10.4.5
OBJECT IDENTIFIER    

memOutletStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.5.1
The number of entries in the memOutletStatusTable.
OBJECT-TYPE    
  INTEGER  

memOutletStatusTable 1.3.6.1.4.1.318.1.1.10.4.5.2
Allows for getting outlet status information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemOutletStatusEntry

memOutletStatusEntry 1.3.6.1.4.1.318.1.1.10.4.5.2.1
The unit to get data from.
OBJECT-TYPE    
  MemOutletStatusEntry  

memOutletStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.5.2.1.1
The number of the module that the outlet is attached to.
OBJECT-TYPE    
  INTEGER  

memOutletStatusOutletNumber 1.3.6.1.4.1.318.1.1.10.4.5.2.1.2
The number of this outlet on the module.
OBJECT-TYPE    
  INTEGER  

memOutletStatusOutletName 1.3.6.1.4.1.318.1.1.10.4.5.2.1.3
The outlet name.
OBJECT-TYPE    
  DisplayString  

memOutletStatusOutletLocation 1.3.6.1.4.1.318.1.1.10.4.5.2.1.4
The location of the outlet.
OBJECT-TYPE    
  DisplayString  

memOutletStatusCurrentState 1.3.6.1.4.1.318.1.1.10.4.5.2.1.5
The state of the outlet.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

memOutletConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.5.3
The number of entries in the memOutletConfigTable.
OBJECT-TYPE    
  INTEGER  

memOutletConfigTable 1.3.6.1.4.1.318.1.1.10.4.5.4
Allows for getting outlet configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemOutletConfigEntry

memOutletConfigEntry 1.3.6.1.4.1.318.1.1.10.4.5.4.1
The unit to get data from.
OBJECT-TYPE    
  MemOutletConfigEntry  

memOutletConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.5.4.1.1
The number of the module that the Outlet is attached to.
OBJECT-TYPE    
  INTEGER  

memOutletConfigOutletNumber 1.3.6.1.4.1.318.1.1.10.4.5.4.1.2
The number of this Outlet on the module.
OBJECT-TYPE    
  INTEGER  

memOutletName 1.3.6.1.4.1.318.1.1.10.4.5.4.1.3
The name of the Outlet.
OBJECT-TYPE    
  DisplayString  

memOutletLocation 1.3.6.1.4.1.318.1.1.10.4.5.4.1.4
The location of the Outlet.
OBJECT-TYPE    
  DisplayString  

memOutletNormalState 1.3.6.1.4.1.318.1.1.10.4.5.4.1.5
The state of the Outlet that will not generate an alarm.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

memOutletAction 1.3.6.1.4.1.318.1.1.10.4.5.4.1.6
Manual control actions for the Outlet. Get displays state of outlet, set controls outlet.
OBJECT-TYPE    
  INTEGER turnOff(1), turnOn(2)  

memBeacons 1.3.6.1.4.1.318.1.1.10.4.6
OBJECT IDENTIFIER    

memBeaconStatusTableSize 1.3.6.1.4.1.318.1.1.10.4.6.1
The number of entries in the memBeaconStatusTable.
OBJECT-TYPE    
  INTEGER  

memBeaconStatusTable 1.3.6.1.4.1.318.1.1.10.4.6.2
Allows for getting beacon status information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemBeaconStatusEntry

memBeaconStatusEntry 1.3.6.1.4.1.318.1.1.10.4.6.2.1
The unit to get data from.
OBJECT-TYPE    
  MemBeaconStatusEntry  

memBeaconStatusModuleNumber 1.3.6.1.4.1.318.1.1.10.4.6.2.1.1
The number of the module that the beacon is attached to.
OBJECT-TYPE    
  INTEGER  

memBeaconStatusBeaconNumber 1.3.6.1.4.1.318.1.1.10.4.6.2.1.2
The number of this beacon on the module.
OBJECT-TYPE    
  INTEGER  

memBeaconStatusBeaconName 1.3.6.1.4.1.318.1.1.10.4.6.2.1.3
The beacon name.
OBJECT-TYPE    
  DisplayString  

memBeaconStatusBeaconLocation 1.3.6.1.4.1.318.1.1.10.4.6.2.1.4
The location of the beacon.
OBJECT-TYPE    
  DisplayString  

memBeaconStatusCurrentState 1.3.6.1.4.1.318.1.1.10.4.6.2.1.5
The state of the beacon.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

memBeaconConfigTableSize 1.3.6.1.4.1.318.1.1.10.4.6.3
The number of entries in the memBeaconConfigTable.
OBJECT-TYPE    
  INTEGER  

memBeaconConfigTable 1.3.6.1.4.1.318.1.1.10.4.6.4
Allows for getting beacon configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    MemBeaconConfigEntry

memBeaconConfigEntry 1.3.6.1.4.1.318.1.1.10.4.6.4.1
The unit to get data from.
OBJECT-TYPE    
  MemBeaconConfigEntry  

memBeaconConfigModuleNumber 1.3.6.1.4.1.318.1.1.10.4.6.4.1.1
The number of the module that the beacon is attached to.
OBJECT-TYPE    
  INTEGER  

memBeaconConfigBeaconNumber 1.3.6.1.4.1.318.1.1.10.4.6.4.1.2
The number of this beacon on the module.
OBJECT-TYPE    
  INTEGER  

memBeaconConfigName 1.3.6.1.4.1.318.1.1.10.4.6.4.1.3
The name of the beacon.
OBJECT-TYPE    
  DisplayString  

memBeaconConfigLocation 1.3.6.1.4.1.318.1.1.10.4.6.4.1.4
The location of the beacon.
OBJECT-TYPE    
  DisplayString  

memBeaconAction 1.3.6.1.4.1.318.1.1.10.4.6.4.1.5
Control action (on/off) for the beacon. Setting this OID will turn the beacon on/off. Getting this OID will respond with the current state.
OBJECT-TYPE    
  INTEGER turnOff(1), turnOn(2)  

netlock 1.3.6.1.4.1.318.1.1.11
OBJECT IDENTIFIER    

nlIdent 1.3.6.1.4.1.318.1.1.11.1
OBJECT IDENTIFIER    

nlStatus 1.3.6.1.4.1.318.1.1.11.2
OBJECT IDENTIFIER    

rPDU 1.3.6.1.4.1.318.1.1.12
OBJECT IDENTIFIER    

rPDUIdent 1.3.6.1.4.1.318.1.1.12.1
OBJECT IDENTIFIER    

rPDUIdentName 1.3.6.1.4.1.318.1.1.12.1.1
The name of the Rack PDU. The maximum string size is device dependent.
OBJECT-TYPE    
  DisplayString  

rPDUIdentHardwareRev 1.3.6.1.4.1.318.1.1.12.1.2
The hardware revision of the Rack PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

rPDUIdentFirmwareRev 1.3.6.1.4.1.318.1.1.12.1.3
An 8-byte ID string identifying the Rack PDU firmware revision. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

rPDUIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.12.1.4
The date when the Rack PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. The year 2000 will be represented by 00.
OBJECT-TYPE    
  DisplayString  

rPDUIdentModelNumber 1.3.6.1.4.1.318.1.1.12.1.5
A 10-character string identifying the model number of the Rack PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

rPDUIdentSerialNumber 1.3.6.1.4.1.318.1.1.12.1.6
A 12-character string identifying the serial number of the Rack PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

rPDUIdentDeviceRating 1.3.6.1.4.1.318.1.1.12.1.7
Getting this OID will return the electrical rating of the device in Amps.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceNumOutlets 1.3.6.1.4.1.318.1.1.12.1.8
Getting this OID will return the number of outlets contained in the device.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceNumPhases 1.3.6.1.4.1.318.1.1.12.1.9
Getting this OID will return the number of phases supported by the device.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceNumBreakers 1.3.6.1.4.1.318.1.1.12.1.10
Getting this OID will return the number of circuit breakers supported by the device. This is the same as the number of banks of outlets. 0 will be returned if the unit has no phase breakers.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceBreakerRating 1.3.6.1.4.1.318.1.1.12.1.11
Getting this OID will return rating of the circuit breakers on the device in Amps if it has any.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceOrientation 1.3.6.1.4.1.318.1.1.12.1.12
Getting this OID will return the intended physical orientation of the device. OrientHorizonatal(1) indicates Horizontal. OrientVertical(2) indicates Vertical.
OBJECT-TYPE    
  INTEGER orientHorizontal(1), orientVertical(2)  

rPDUIdentDeviceOutletLayout 1.3.6.1.4.1.318.1.1.12.1.13
Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available.
OBJECT-TYPE    
  INTEGER seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9)  

rPDUIdentDeviceDisplayOrientation 1.3.6.1.4.1.318.1.1.12.1.14
Getting this OID will return the intended physical orientation of the Seven-Segment Display. Normal(1) indicates Normal. Reverse(2)indicates Upside-Down.
OBJECT-TYPE    
  INTEGER displayNormal(1), displayReverse(2)  

rPDUIdentDeviceLinetoLineVoltage 1.3.6.1.4.1.318.1.1.12.1.15
Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. The valid range is between 0V to 440V
OBJECT-TYPE    
  INTEGER  

rPDUIdentDevicePowerWatts 1.3.6.1.4.1.318.1.1.12.1.16
Getting this OID will return the Power in Watts.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDevicePowerFactor 1.3.6.1.4.1.318.1.1.12.1.17
Getting/setting this OID will return/set the Power Factor in thousanths (1000 is power factor of 1). This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. Valid range is from 0 to 1000.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDevicePowerVA 1.3.6.1.4.1.318.1.1.12.1.18
Getting this OID will return the Power in VA.
OBJECT-TYPE    
  INTEGER  

rPDUIdentDeviceLinetoNeutralVoltage 1.3.6.1.4.1.318.1.1.12.1.19
Getting/Setting this OID will return/set the Line to Neutral Voltage. This OID defaults to the nominal line to neutral voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID applies only to AP7823. For all other models, the OID is fixed at 0. The valid range is between 0V to 440V.
OBJECT-TYPE    
  INTEGER  

rPDULoad 1.3.6.1.4.1.318.1.1.12.2
OBJECT IDENTIFIER    

rPDULoadDevice 1.3.6.1.4.1.318.1.1.12.2.1
OBJECT IDENTIFIER    

rPDULoadDevMaxPhaseLoad 1.3.6.1.4.1.318.1.1.12.2.1.1
Getting this OID will return the maximum rated power that each phase of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the unit is banked.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevNumPhases 1.3.6.1.4.1.318.1.1.12.2.1.2
The number of phases available with this Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevMaxBankLoad 1.3.6.1.4.1.318.1.1.12.2.1.3
Getting this OID will return the maximum rated power that a bank of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the device does not have any banks.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevNumBanks 1.3.6.1.4.1.318.1.1.12.2.1.4
The number of banks of outlets available with this Rack PDU. A bank of outlets has a unique circuit breaker for a subset of the total number of outlets on the rPDU. 0 will be returned if the unit has no banks.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevBankTableSize 1.3.6.1.4.1.318.1.1.12.2.1.5
The size of the Bank Table.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevBankTable 1.3.6.1.4.1.318.1.1.12.2.1.6
Allows for getting the Bank Max Load in the Rack PDU.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDULoadDevBankEntry

rPDULoadDevBankEntry 1.3.6.1.4.1.318.1.1.12.2.1.6.1
The Rack PDU Banks Access.
OBJECT-TYPE    
  RPDULoadDevBankEntry  

rPDULoadDevBankIndex 1.3.6.1.4.1.318.1.1.12.2.1.6.1.1
The index to the Rack PDU bank entry.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevBankNumber 1.3.6.1.4.1.318.1.1.12.2.1.6.1.2
Getting this OID will return the bank number.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevBankMaxLoad 1.3.6.1.4.1.318.1.1.12.2.1.6.1.3
Getting this OID will return the maximum rated power that each bank of the Rack PDU can provide. It is represented in Amps.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevMaxOutletTableSize 1.3.6.1.4.1.318.1.1.12.2.1.7
The size of the Outlet Table.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevMaxOutletTable 1.3.6.1.4.1.318.1.1.12.2.1.8
Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDULoadDevMaxOutletEntry

rPDULoadDevMaxOutletEntry 1.3.6.1.4.1.318.1.1.12.2.1.8.1
This gives access to Max Outlet Load of an Outlet Monitored Rack PDU
OBJECT-TYPE    
  RPDULoadDevMaxOutletEntry  

rPDULoadDevOutletIndex 1.3.6.1.4.1.318.1.1.12.2.1.8.1.1
The index to the Outlet Monitored Rack PDU Max Outlet Load entry.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevOutletNumber 1.3.6.1.4.1.318.1.1.12.2.1.8.1.2
Getting this OID will return the Outlet number.
OBJECT-TYPE    
  INTEGER  

rPDULoadDevMaxOutletLoad 1.3.6.1.4.1.318.1.1.12.2.1.8.1.3
Getting this OID will return the maximum rated power that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps.
OBJECT-TYPE    
  INTEGER  

rPDULoadPhaseConfig 1.3.6.1.4.1.318.1.1.12.2.2
OBJECT IDENTIFIER    

rPDULoadPhaseConfigTable 1.3.6.1.4.1.318.1.1.12.2.2.1
Allows for configuration of each Rack PDU phase. The number of entries is contained in the rPDULoadDevNumPhases OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDULoadPhaseConfigEntry

rPDULoadPhaseConfigEntry 1.3.6.1.4.1.318.1.1.12.2.2.1.1
The Rack PDU phase to configure.
OBJECT-TYPE    
  RPDULoadPhaseConfigEntry  

rPDULoadPhaseConfigIndex 1.3.6.1.4.1.318.1.1.12.2.2.1.1.1
The index to the Rack PDU phase entry.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

rPDULoadPhaseConfigLowLoadThreshold 1.3.6.1.4.1.318.1.1.12.2.2.1.1.2
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadPhaseConfigNearOverloadThreshold 1.3.6.1.4.1.318.1.1.12.2.2.1.1.3
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadPhaseConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadPhaseConfigOverloadThreshold OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadPhaseConfigOverloadThreshold 1.3.6.1.4.1.318.1.1.12.2.2.1.1.4
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxPhaseLoad OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadPhaseConfigAlarm 1.3.6.1.4.1.318.1.1.12.2.2.1.1.5
Getting this OID will return the current Phase Alarm.
OBJECT-TYPE    
  INTEGER noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)  

rPDULoadStatus 1.3.6.1.4.1.318.1.1.12.2.3
OBJECT IDENTIFIER    

rPDULoadStatusTable 1.3.6.1.4.1.318.1.1.12.2.3.1
Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (rPDULoadDevNumPhases OID) and the number of banks of outlets (rPDULoadDevNumBanks) Number of entries = #phases + #banks. NOTE: If a device has phase and bank information, all phase information shall precede the bank information. If a device has total information, it shall precede both the bank and the phase information.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDULoadStatusEntry

rPDULoadStatusEntry 1.3.6.1.4.1.318.1.1.12.2.3.1.1
The Rack PDU phase/bank to gather status from.
OBJECT-TYPE    
  RPDULoadStatusEntry  

rPDULoadStatusIndex 1.3.6.1.4.1.318.1.1.12.2.3.1.1.1
The index to the Rack PDU phase/bank entry. All phase information will precede any bank information
OBJECT-TYPE    
  INTEGER  

rPDULoadStatusLoad 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2
Getting this OID will return the phase/bank load measured in tenths of Amps.
OBJECT-TYPE    
  Gauge  

rPDULoadStatusLoadState 1.3.6.1.4.1.318.1.1.12.2.3.1.1.3
Getting this OID will return the phase/bank load state. phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the phase/bank load has dropped below the rPDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)  

rPDULoadStatusPhaseNumber 1.3.6.1.4.1.318.1.1.12.2.3.1.1.4
The phase number to which this record refers.
OBJECT-TYPE    
  INTEGER  

rPDULoadStatusBankNumber 1.3.6.1.4.1.318.1.1.12.2.3.1.1.5
The bank number to which this record refers. A value of 0 will be returned if any bank is not present or if it is phase related.
OBJECT-TYPE    
  INTEGER  

rPDULoadBankConfig 1.3.6.1.4.1.318.1.1.12.2.4
OBJECT IDENTIFIER    

rPDULoadBankConfigTable 1.3.6.1.4.1.318.1.1.12.2.4.1
Allows for configuration of each Rack PDU bank. The number of entries is contained in the rPDULoadDevNumBanks OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDULoadBankConfigEntry

rPDULoadBankConfigEntry 1.3.6.1.4.1.318.1.1.12.2.4.1.1
The Rack PDU bank to configure.
OBJECT-TYPE    
  RPDULoadBankConfigEntry  

rPDULoadBankConfigIndex 1.3.6.1.4.1.318.1.1.12.2.4.1.1.1
The index to the Rack PDU bank entry.
OBJECT-TYPE    
  INTEGER  

rPDULoadBankConfigLowLoadThreshold 1.3.6.1.4.1.318.1.1.12.2.4.1.1.2
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadBankConfigNearOverloadThreshold OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadBankConfigNearOverloadThreshold 1.3.6.1.4.1.318.1.1.12.2.4.1.1.3
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadBankConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadBankConfigOverloadThreshold OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadBankConfigOverloadThreshold 1.3.6.1.4.1.318.1.1.12.2.4.1.1.4
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadBankConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxBankLoad OID.
OBJECT-TYPE    
  INTEGER  

rPDULoadBankConfigAlarm 1.3.6.1.4.1.318.1.1.12.2.4.1.1.5
Getting this OID will return the current Bank Alarm.
OBJECT-TYPE    
  INTEGER noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)  

rPDUOutlet 1.3.6.1.4.1.318.1.1.12.3
OBJECT IDENTIFIER    

rPDUOutletDevice 1.3.6.1.4.1.318.1.1.12.3.1
OBJECT IDENTIFIER    

rPDUOutletDevCommand 1.3.6.1.4.1.318.1.1.12.3.1.1
Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will reboot all outlets immediately. Setting this OID to delayedAllOn (5) will turn all outlets on as defined by each outlet's rPDUOutletConfigPowerOnTime OID value. Setting this OID to delayedAllOff (6) will turn all outlets off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value. Setting this OID to delayedAllReboot (7) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDUOutletConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be canceled. Getting this OID will return the noCommandAll (1) value.
OBJECT-TYPE    
  INTEGER noCommandAll(1), immediateAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllOn(5), delayedAllOff(6), delayedAllReboot(7), cancelAllPendingCommands(8)  

rPDUOutletDevColdstartDelay 1.3.6.1.4.1.318.1.1.12.3.1.2
The amount of delay, in seconds, between when power is provided to the Switched Rack PDU and when the Switched Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes).
OBJECT-TYPE    
  INTEGER  

rPDUOutletDevNumCntrlOutlets 1.3.6.1.4.1.318.1.1.12.3.1.3
The number of controlled outlets on this Switched Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletDevNumTotalOutlets 1.3.6.1.4.1.318.1.1.12.3.1.4
The total number of outlets on this Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletDevMonitoredOutlets 1.3.6.1.4.1.318.1.1.12.3.1.5
The total number of monitored outlets on this Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletPhase 1.3.6.1.4.1.318.1.1.12.3.2
OBJECT IDENTIFIER    

rPDUOutletPhaseTable 1.3.6.1.4.1.318.1.1.12.3.2.1
Allows for management of outlets on a per phase basis.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletPhaseEntry

rPDUOutletPhaseEntry 1.3.6.1.4.1.318.1.1.12.3.2.1.1
The phase to manage.
OBJECT-TYPE    
  RPDUOutletPhaseEntry  

rPDUOutletPhaseIndex 1.3.6.1.4.1.318.1.1.12.3.2.1.1.1
The index to the Switched Rack PDU phase entry.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

rPDUOutletPhaseOverloadRestriction 1.3.6.1.4.1.318.1.1.12.3.2.1.1.2
This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded.
OBJECT-TYPE    
  INTEGER alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)  

rPDUOutletControl 1.3.6.1.4.1.318.1.1.12.3.3
OBJECT IDENTIFIER    

rPDUOutletControlTable 1.3.6.1.4.1.318.1.1.12.3.3.1
Allows for control of the individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletControlEntry

rPDUOutletControlEntry 1.3.6.1.4.1.318.1.1.12.3.3.1.1
The outlet to control.
OBJECT-TYPE    
  RPDUOutletControlEntry  

rPDUOutletControlIndex 1.3.6.1.4.1.318.1.1.12.3.3.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

rPDUOutletControlOutletName 1.3.6.1.4.1.318.1.1.12.3.3.1.1.2
The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

rPDUOutletControlOutletPhase 1.3.6.1.4.1.318.1.1.12.3.3.1.1.3
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

rPDUOutletControlOutletCommand 1.3.6.1.4.1.318.1.1.12.3.3.1.1.4
Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the rPDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the rPDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDUOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled.
OBJECT-TYPE    
  INTEGER immediateOn(1), immediateOff(2), immediateReboot(3), delayedOn(4), delayedOff(5), delayedReboot(6), cancelPendingCommand(7)  

rPDUOutletControlOutletBank 1.3.6.1.4.1.318.1.1.12.3.3.1.1.5
The bank associated with this outlet.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfig 1.3.6.1.4.1.318.1.1.12.3.4
OBJECT IDENTIFIER    

rPDUOutletConfigTable 1.3.6.1.4.1.318.1.1.12.3.4.1
Allows for configuration of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletConfigEntry

rPDUOutletConfigEntry 1.3.6.1.4.1.318.1.1.12.3.4.1.1
The outlet to configure.
OBJECT-TYPE    
  RPDUOutletConfigEntry  

rPDUOutletConfigIndex 1.3.6.1.4.1.318.1.1.12.3.4.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigOutletName 1.3.6.1.4.1.318.1.1.12.3.4.1.1.2
The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size.
OBJECT-TYPE    
  DisplayString  

rPDUOutletConfigOutletPhase 1.3.6.1.4.1.318.1.1.12.3.4.1.1.3
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

rPDUOutletConfigPowerOnTime 1.3.6.1.4.1.318.1.1.12.3.4.1.1.4
The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigPowerOffTime 1.3.6.1.4.1.318.1.1.12.3.4.1.1.5
The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigRebootDuration 1.3.6.1.4.1.318.1.1.12.3.4.1.1.6
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute).
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigOutletBank 1.3.6.1.4.1.318.1.1.12.3.4.1.1.7
The bank associated with this outlet.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredTableSize 1.3.6.1.4.1.318.1.1.12.3.4.2
The size of the Outlet Config Monitored Table
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredTable 1.3.6.1.4.1.318.1.1.12.3.4.3
Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletConfigMonitoredEntry

rPDUOutletConfigMonitoredEntry 1.3.6.1.4.1.318.1.1.12.3.4.3.1
This gives access to Monitored Outlet entries
OBJECT-TYPE    
  RPDUOutletConfigMonitoredEntry  

rPDUOutletConfigMonitoredIndex 1.3.6.1.4.1.318.1.1.12.3.4.3.1.1
The index to the RACK PDU Phase entry.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredName 1.3.6.1.4.1.318.1.1.12.3.4.3.1.2
The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size.
OBJECT-TYPE    
  DisplayString  

rPDUOutletConfigMonitoredNumber 1.3.6.1.4.1.318.1.1.12.3.4.3.1.3
The outlet number of an Outlet Monitored RACK PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredLowLoadThreshold 1.3.6.1.4.1.318.1.1.12.3.4.3.1.4
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredNearOverloadThreshold 1.3.6.1.4.1.318.1.1.12.3.4.3.1.5
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDUOutletConfigMonitoredLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDUOutletConfigMonitoredOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletConfigMonitoredOverloadThreshold 1.3.6.1.4.1.318.1.1.12.3.4.3.1.6
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxOutletLoad OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
OBJECT-TYPE    
  INTEGER  

rPDUOutletStatus 1.3.6.1.4.1.318.1.1.12.3.5
OBJECT IDENTIFIER    

rPDUOutletStatusTable 1.3.6.1.4.1.318.1.1.12.3.5.1
Allows for getting of status of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID or rPDUOutletDevMonitoredOutlets OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletStatusEntry

rPDUOutletStatusEntry 1.3.6.1.4.1.318.1.1.12.3.5.1.1
The outlet to gather status from.
OBJECT-TYPE    
  RPDUOutletStatusEntry  

rPDUOutletStatusIndex 1.3.6.1.4.1.318.1.1.12.3.5.1.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

rPDUOutletStatusOutletName 1.3.6.1.4.1.318.1.1.12.3.5.1.1.2
The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only.
OBJECT-TYPE    
  DisplayString  

rPDUOutletStatusOutletPhase 1.3.6.1.4.1.318.1.1.12.3.5.1.1.3
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

rPDUOutletStatusOutletState 1.3.6.1.4.1.318.1.1.12.3.5.1.1.4
Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned.
OBJECT-TYPE    
  INTEGER outletStatusOn(1), outletStatusOff(2)  

rPDUOutletStatusCommandPending 1.3.6.1.4.1.318.1.1.12.3.5.1.1.5
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
OBJECT-TYPE    
  INTEGER outletStatusCommandPending(1), outletStatusNoCommandPending(2)  

rPDUOutletStatusOutletBank 1.3.6.1.4.1.318.1.1.12.3.5.1.1.6
The bank associated with this outlet.
OBJECT-TYPE    
  INTEGER  

rPDUOutletStatusLoad 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7
Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. For other models this OID is not supported.
OBJECT-TYPE    
  Gauge  

rPDUOutletBank 1.3.6.1.4.1.318.1.1.12.3.6
OBJECT IDENTIFIER    

rPDUOutletBankTable 1.3.6.1.4.1.318.1.1.12.3.6.1
Allows for management of outlets on a per bank basis.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUOutletBankEntry

rPDUOutletBankEntry 1.3.6.1.4.1.318.1.1.12.3.6.1.1
The bank to manage.
OBJECT-TYPE    
  RPDUOutletBankEntry  

rPDUOutletBankIndex 1.3.6.1.4.1.318.1.1.12.3.6.1.1.1
The index to the Switched Rack PDU bank entry.
OBJECT-TYPE    
  INTEGER  

rPDUOutletBankOverloadRestriction 1.3.6.1.4.1.318.1.1.12.3.6.1.1.2
This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigOverloadThreshold OID is exceeded.
OBJECT-TYPE    
  INTEGER alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)  

rPDUPowerSupply 1.3.6.1.4.1.318.1.1.12.4
OBJECT IDENTIFIER    

rPDUPowerSupplyDevice 1.3.6.1.4.1.318.1.1.12.4.1
OBJECT IDENTIFIER    

rPDUPowerSupply1Status 1.3.6.1.4.1.318.1.1.12.4.1.1
Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(2).
OBJECT-TYPE    
  INTEGER powerSupplyOneOk(1), powerSupplyOneFailed(2)  

rPDUPowerSupply2Status 1.3.6.1.4.1.318.1.1.12.4.1.2
Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(2). Metered Rack PDUs do not have a redundant powersupply.
OBJECT-TYPE    
  INTEGER powerSupplyTwoOk(1), powerSupplyTwoFailed(2), powerSupplyTwoNotPresent(3)  

rPDUPowerSupplyAlarm 1.3.6.1.4.1.318.1.1.12.4.1.3
Getting this OID will return powerSupply Alarm
OBJECT-TYPE    
  INTEGER allAvailablePowerSuppliesOK(1), powerSupplyOneFailed(2), powerSupplyTwoFailed(3), powerSupplyOneandTwoFailed(4)  

rPDUStatus 1.3.6.1.4.1.318.1.1.12.5
OBJECT IDENTIFIER    

rPDUStatusBankTableSize 1.3.6.1.4.1.318.1.1.12.5.1
The size of the Status Bank Table
OBJECT-TYPE    
  INTEGER  

rPDUStatusBankTable 1.3.6.1.4.1.318.1.1.12.5.2
Allows for getting of status of each Rack PDU Bank
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUStatusBankEntry

rPDUStatusBankEntry 1.3.6.1.4.1.318.1.1.12.5.2.1
This gives access to Bank entries
OBJECT-TYPE    
  RPDUStatusBankEntry  

rPDUStatusBankIndex 1.3.6.1.4.1.318.1.1.12.5.2.1.1
The index to the RACK PDU Bank entry.
OBJECT-TYPE    
  INTEGER  

rPDUStatusBankNumber 1.3.6.1.4.1.318.1.1.12.5.2.1.2
Getting this OID will return the bank number.
OBJECT-TYPE    
  INTEGER  

rPDUStatusBankState 1.3.6.1.4.1.318.1.1.12.5.2.1.3
Getting this OID will return the bank load state. bankLoadNormal(1) indicates that the bank is operating properly within the rPDULoadBankConfigLowLoadThreshold and rPDULoadBankConfigNearOverloadThreshold OID values. bankLoadLow(2) indicates that the bank load has dropped below the rPDULoadBankConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadNearOverload(3) indicates that the bank load is greater than or equal to the rPDULoadBankConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadOverload(4) indicates that the bank load is greater than or equal to the rPDULoadBankConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER bankLoadNormal(1), bankLoadLow(2), bankLoadNearOverload(3), bankLoadOverload(4)  

rPDUStatusPhaseTableSize 1.3.6.1.4.1.318.1.1.12.5.3
The size of the Status Phase Table
OBJECT-TYPE    
  INTEGER  

rPDUStatusPhaseTable 1.3.6.1.4.1.318.1.1.12.5.4
Allows for getting of status of each Rack PDU Phase
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUStatusPhaseEntry

rPDUStatusPhaseEntry 1.3.6.1.4.1.318.1.1.12.5.4.1
This gives access to Phase entries
OBJECT-TYPE    
  RPDUStatusPhaseEntry  

rPDUStatusPhaseIndex 1.3.6.1.4.1.318.1.1.12.5.4.1.1
The index to the RACK PDU Phase entry.
OBJECT-TYPE    
  INTEGER  

rPDUStatusPhaseNumber 1.3.6.1.4.1.318.1.1.12.5.4.1.2
Getting this OID will return the phase number.
OBJECT-TYPE    
  INTEGER  

rPDUStatusPhaseState 1.3.6.1.4.1.318.1.1.12.5.4.1.3
Getting this OID will return the Phase load state. phaseLoadNormal(1) indicates that the Phase is operating properly within the rPDULoadPhaseConfigLowLoadThreshold and rPDULoadPhaseConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the Phase load has dropped below the rPDULoadPhaseConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)  

rPDUStatusOutletTableSize 1.3.6.1.4.1.318.1.1.12.5.5
The size of the Status Outlet Table
OBJECT-TYPE    
  INTEGER  

rPDUStatusOutletTable 1.3.6.1.4.1.318.1.1.12.5.6
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
OBJECT-TYPE    
  SEQUENCE OF  
    RPDUStatusOutletEntry

rPDUStatusOutletEntry 1.3.6.1.4.1.318.1.1.12.5.6.1
This gives access to Outlet entries
OBJECT-TYPE    
  RPDUStatusOutletEntry  

rPDUStatusOutletIndex 1.3.6.1.4.1.318.1.1.12.5.6.1.1
The index to the RACK PDU Outlet entry.
OBJECT-TYPE    
  INTEGER  

rPDUStatusOutletNumber 1.3.6.1.4.1.318.1.1.12.5.6.1.2
Getting this OID will return the Outlet number.
OBJECT-TYPE    
  INTEGER  

rPDUStatusOutletState 1.3.6.1.4.1.318.1.1.12.5.6.1.3
Getting this OID will return the Outlet load state. outletLoadNormal(1) indicates that the Outlet is operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold and rPDUOutletConfigMonitoredNearOverloadThreshold OID values. outletLoadLow(2) indicates that the Outlet load has dropped below the rPDUOutletConfigMonitoredLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadNearOverload(3) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadOverload(4) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
OBJECT-TYPE    
  INTEGER outletLoadNormal(1), outletLoadLow(2), outletLoadNearOverload(3), outletLoadOverload(4)  

airConditioners 1.3.6.1.4.1.318.1.1.13
OBJECT IDENTIFIER    

airFM 1.3.6.1.4.1.318.1.1.13.1
OBJECT IDENTIFIER    

airFMIdent 1.3.6.1.4.1.318.1.1.13.1.1
OBJECT IDENTIFIER    

airFMIdentName 1.3.6.1.4.1.318.1.1.13.1.1.1
A character string identifying the device.
OBJECT-TYPE    
  DisplayString  

airFMIdentTableSize 1.3.6.1.4.1.318.1.1.13.1.1.2
The number of entries in the airFMIdentTable.
OBJECT-TYPE    
  INTEGER  

airFMIdentTable 1.3.6.1.4.1.318.1.1.13.1.1.3
Allows for getting identification information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMIdentEntry

airFMIdentEntry 1.3.6.1.4.1.318.1.1.13.1.1.3.1
The module to get information from.
OBJECT-TYPE    
  AirFMIdentEntry  

airFMIdentModuleIndex 1.3.6.1.4.1.318.1.1.13.1.1.3.1.1
The index of the module information.
OBJECT-TYPE    
  INTEGER  

airFMIdentModuleModelNumber 1.3.6.1.4.1.318.1.1.13.1.1.3.1.2
A character string identifying the model number.
OBJECT-TYPE    
  DisplayString  

airFMIdentModuleDateOfMfg 1.3.6.1.4.1.318.1.1.13.1.1.3.1.3
A character string identifying the manufacture date.
OBJECT-TYPE    
  DisplayString  

airFMIdentModuleSerialNumber 1.3.6.1.4.1.318.1.1.13.1.1.3.1.4
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airFMIdentModuleFirmwareRev 1.3.6.1.4.1.318.1.1.13.1.1.3.1.5
A character string identifying the firmware revision.
OBJECT-TYPE    
  DisplayString  

airFMIdentModuleHardwareRev 1.3.6.1.4.1.318.1.1.13.1.1.3.1.6
A character string identifying the hardware revision.
OBJECT-TYPE    
  DisplayString  

airFMIdentLocation 1.3.6.1.4.1.318.1.1.13.1.1.4
A character string identifying the location of the device.
OBJECT-TYPE    
  DisplayString  

airFMIdentContact 1.3.6.1.4.1.318.1.1.13.1.1.5
A character string identifying the person to contact regarding the device.
OBJECT-TYPE    
  DisplayString  

airFMStatus 1.3.6.1.4.1.318.1.1.13.1.2
OBJECT IDENTIFIER    

airFMStatusSystemOn 1.3.6.1.4.1.318.1.1.13.1.2.1
The operating state of the system. This OID has been deprecated in favor of airFMGroupSysStatus.
OBJECT-TYPE    
  INTEGER statusOn(1), statusOff(2)  

airFMStatusSystemAverageRetTempC 1.3.6.1.4.1.318.1.1.13.1.2.2
The system average return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgReturnTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemAverageRetTempF 1.3.6.1.4.1.318.1.1.13.1.2.3
The system average return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgReturnTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemAverageRetHum 1.3.6.1.4.1.318.1.1.13.1.2.4
The system average return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgReturnHum.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemActionTempC 1.3.6.1.4.1.318.1.1.13.1.2.5
The system action air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysCtrlTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemActionTempF 1.3.6.1.4.1.318.1.1.13.1.2.6
The system action air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysCtrlTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemActionHum 1.3.6.1.4.1.318.1.1.13.1.2.7
The system action air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysCtrlHum.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteHighTempC 1.3.6.1.4.1.318.1.1.13.1.2.8
The system remote high air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMaxRemoteTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteHighTempF 1.3.6.1.4.1.318.1.1.13.1.2.9
The system remote high air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMaxRemoteTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteAvgTempC 1.3.6.1.4.1.318.1.1.13.1.2.10
The system remote average air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgRemoteTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteAvgTempF 1.3.6.1.4.1.318.1.1.13.1.2.11
The system remote average air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgRemoteTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteAvgHum 1.3.6.1.4.1.318.1.1.13.1.2.12
The system remote average air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgRemoteHum.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteLowTempC 1.3.6.1.4.1.318.1.1.13.1.2.13
The system remote low air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMinRemoteTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemRemoteLowTempF 1.3.6.1.4.1.318.1.1.13.1.2.14
The system remote low air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMinRemoteTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusSystemCoolingEnabled 1.3.6.1.4.1.318.1.1.13.1.2.15
The state of the system cooling function enable. This OID has been deprecated in favor of airFMSysCoolState.
OBJECT-TYPE    
  INTEGER enabledYes(1), enabledNo(2)  

airFMStatusSystemReheatingEnabled 1.3.6.1.4.1.318.1.1.13.1.2.16
The state of the system reheating function enable. This OID has been deprecated in favor of airFMSysReheatState.
OBJECT-TYPE    
  INTEGER enabledYes(1), enabledNo(2)  

airFMStatusSystemHumidifyEnabled 1.3.6.1.4.1.318.1.1.13.1.2.17
The state of the system humidify function enable. This OID has been deprecated in favor of airFMSysHumState.
OBJECT-TYPE    
  INTEGER enabledYes(1), enabledNo(2)  

airFMStatusSystemDehumidifyEnabled 1.3.6.1.4.1.318.1.1.13.1.2.18
The state of the system dehumidify function enable. This OID has been deprecated in favor of airFMSysDehumState.
OBJECT-TYPE    
  INTEGER enabledYes(1), enabledNo(2)  

airFMStatusModuleTableSize 1.3.6.1.4.1.318.1.1.13.1.2.19
The number of entries in the airFMStatusModuleTable.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleTable 1.3.6.1.4.1.318.1.1.13.1.2.20
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMStatusModuleEntry

airFMStatusModuleEntry 1.3.6.1.4.1.318.1.1.13.1.2.20.1
The module to get status from.
OBJECT-TYPE    
  AirFMStatusModuleEntry  

airFMStatusModuleIndex 1.3.6.1.4.1.318.1.1.13.1.2.20.1.1
The index of the module information.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleOutputCapacity 1.3.6.1.4.1.318.1.1.13.1.2.20.1.2
The module output capacity in kilowatts. This OID has been deprecated in favor of airFMModOutputCapacity.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleSupplyTempC 1.3.6.1.4.1.318.1.1.13.1.2.20.1.3
The module supply air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModSupplyTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleSupplyTempF 1.3.6.1.4.1.318.1.1.13.1.2.20.1.4
The module supply air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModSupplyTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleSupplyHum 1.3.6.1.4.1.318.1.1.13.1.2.20.1.5
The module supply air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModSupplyHum.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleReturnTempC 1.3.6.1.4.1.318.1.1.13.1.2.20.1.6
The module return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModReturnTempC.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleReturnTempF 1.3.6.1.4.1.318.1.1.13.1.2.20.1.7
The module return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModReturnTempF.
OBJECT-TYPE    
  INTEGER  

airFMStatusModuleReturnHum 1.3.6.1.4.1.318.1.1.13.1.2.20.1.8
The module return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModReturnHum.
OBJECT-TYPE    
  INTEGER  

airFMGroup 1.3.6.1.4.1.318.1.1.13.1.3
OBJECT IDENTIFIER    

airFMGroupSysStatus 1.3.6.1.4.1.318.1.1.13.1.3.1
The status of this system within the group.
OBJECT-TYPE    
  INTEGER statusOnLine(1), statusIdle(2), statusLoadShare(3), statusOffLine(4), statusFailed(5), statusDisabled(6), statusUndefined(7)  

airFMGroupSysRuntime 1.3.6.1.4.1.318.1.1.13.1.3.2
The number of hours the system has been running.
OBJECT-TYPE    
  INTEGER  

airFMGroupSysRole 1.3.6.1.4.1.318.1.1.13.1.3.3
The role of this system within the group.
OBJECT-TYPE    
  INTEGER rolePrimary(1), roleBackup(2)  

airFMGroupSysRoles 1.3.6.1.4.1.318.1.1.13.1.3.4
OBJECT IDENTIFIER    

airFMGroupSysRolesTableSize 1.3.6.1.4.1.318.1.1.13.1.3.4.1
The number of entries in the airFMGroupSysRolesTable.
OBJECT-TYPE    
  INTEGER  

airFMGroupSysRolesTable 1.3.6.1.4.1.318.1.1.13.1.3.4.2
Allows for getting information from each system in the group.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMGroupSysRolesEntry

airFMGroupSysRolesEntry 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1
The system to get status from.
OBJECT-TYPE    
  AirFMGroupSysRolesEntry  

airFMGroupSysIndex 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.1
The index of the system information.
OBJECT-TYPE    
  INTEGER  

airFMGroupSysRoleStatus 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.2
The present mode of the System.
OBJECT-TYPE    
  INTEGER reserved1(1), reserved2(2), onLine(3), idle(4), loadShare(5), failed(6), offLine(7)  

airFMGroupSysPresentRole 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.3
The present role of the System in a Group.
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

airFMGroupSysManualRoleSetting 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.4
The manual role setting of the System in a Group. Only applies if Role Assignment Method is set to static (Manually Assigned Roles).
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

airFMGroupSysRunHours 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.5
The total number of hours the System has been contributing to environmental control.
OBJECT-TYPE    
  INTEGER  

airFMGroupSysComm 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.6
Indicates whether a system is communicating with the other Systems in the Group.
OBJECT-TYPE    
  INTEGER commLost(1), commEstablished(2)  

airFMGroupSysIPAddress 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.7
The IP Address of the System.
OBJECT-TYPE    
  IpAddress  

airFMGroupSysRoleAssignment 1.3.6.1.4.1.318.1.1.13.1.3.4.3
The method used to assign roles (i.e. Primary, Backup) to the Systems in a Group. staticManual: Manually assign Primary or Backup to regulate run hours across the Group. dynamicAutomatic: User indicates the number of Systems that will be assigned a primary role in this Group.
OBJECT-TYPE    
  INTEGER staticManual(1), dynamicAutomatic(2)  

airFMGroupAutoRoleNumPrimary 1.3.6.1.4.1.318.1.1.13.1.3.4.4
The number of Systems assigned the 'primary' role in this Group. Only applies if Role Assignment Method is set to dynamic (Automatic Run Hour Balancing).
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4)  

airFMGroupCfg 1.3.6.1.4.1.318.1.1.13.1.3.5
OBJECT IDENTIFIER    

airFMGroupCfgName 1.3.6.1.4.1.318.1.1.13.1.3.5.1
A character string identifying the group name.
OBJECT-TYPE    
  DisplayString  

airFMGroupCfgNumSystems 1.3.6.1.4.1.318.1.1.13.1.3.5.2
The number of Systems in this Group.
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4)  

airFMGroupCfgIdleBlower 1.3.6.1.4.1.318.1.1.13.1.3.5.3
Blower behavior for backup Systems and Systems that have entered a failure mode.
OBJECT-TYPE    
  INTEGER off(1), minimumSpeed(2), normalSpeed(3)  

airFMGroupCfgShutdownSmoke 1.3.6.1.4.1.318.1.1.13.1.3.5.4
If enabled, all Systems in the Group will shut down if smoke is detected.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupCfgShutdownFire 1.3.6.1.4.1.318.1.1.13.1.3.5.5
If enabled, all Systems in the Group will shut down if fire is detected.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupCfgFailoverCommLoss 1.3.6.1.4.1.318.1.1.13.1.3.5.6
Failover on Comm Loss enables an available backup System to run in place of a System that has lost communication with the Group.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupCfgDmdFightStatus 1.3.6.1.4.1.318.1.1.13.1.3.5.7
Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to a Load Sharing Request.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

airFMGroupCfgDmdFightSetting 1.3.6.1.4.1.318.1.1.13.1.3.5.8
Demand Fighting prevents a System from engaging reheat in a Group where any System is cooling.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupCfgSetpointShareStatus 1.3.6.1.4.1.318.1.1.13.1.3.5.9
Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to Load Sharing Request.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

airFMGroupCfgSetpointShareSetting 1.3.6.1.4.1.318.1.1.13.1.3.5.10
All Systems in the Group use the same setpoints.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupCfgResetFieldServiceDefaults 1.3.6.1.4.1.318.1.1.13.1.3.5.11
Setting this OID to reset(2) will reset all Group parameters, which can only be edited by a field service engineer, to their factory default values. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

airFMGroupLoadShare 1.3.6.1.4.1.318.1.1.13.1.3.6
OBJECT IDENTIFIER    

airFMGroupLoadShareCoolRequests 1.3.6.1.4.1.318.1.1.13.1.3.6.1
Systems that are cooling may request assistance from other Systems in the Group.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupLoadShareCoolThreshC 1.3.6.1.4.1.318.1.1.13.1.3.6.2
Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airFMGroupLoadShareCoolThreshF 1.3.6.1.4.1.318.1.1.13.1.3.6.3
Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airFMGroupLoadShareReheatRequests 1.3.6.1.4.1.318.1.1.13.1.3.6.4
Systems that are reheating may request assistance from other Systems in the Group.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupLoadShareReheatThreshC 1.3.6.1.4.1.318.1.1.13.1.3.6.5
Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airFMGroupLoadShareReheatThreshF 1.3.6.1.4.1.318.1.1.13.1.3.6.6
Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airFMGroupLoadShareHumRequests 1.3.6.1.4.1.318.1.1.13.1.3.6.7
Systems that are humidifying may request humidification assistance from other Systems in the Group.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupLoadShareHumThresh 1.3.6.1.4.1.318.1.1.13.1.3.6.8
Humidity threshold at which a System will generate a load sharing request for humidification. Measured in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airFMGroupLoadShareDehumRequests 1.3.6.1.4.1.318.1.1.13.1.3.6.9
Systems that are dehumidifying may request assistance from other Systems in the Group.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airFMGroupLoadShareDehumThresh 1.3.6.1.4.1.318.1.1.13.1.3.6.10
Humidity threshold at which a System will generate a load sharing request for dehumidification. Measured in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airFMGroupFailover 1.3.6.1.4.1.318.1.1.13.1.3.7
OBJECT IDENTIFIER    

airFMGroupFailoverSys 1.3.6.1.4.1.318.1.1.13.1.3.7.1
OBJECT IDENTIFIER    

airFMGroupFailoverSysAnyMinorAlarm 1.3.6.1.4.1.318.1.1.13.1.3.7.1.1
Enabling this OID will cause the system to enter a failure state if any minor system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysAnyMajorAlarm 1.3.6.1.4.1.318.1.1.13.1.3.7.1.2
Enabling this OID will cause the system to enter a failure state if any major system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysHighEnvTemp 1.3.6.1.4.1.318.1.1.13.1.3.7.1.3
Enabling this OID will cause the system to enter a failure state if the high environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysLowEnvTemp 1.3.6.1.4.1.318.1.1.13.1.3.7.1.4
Enabling this OID will cause the system to enter a failure state if the low environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysHighEnvHum 1.3.6.1.4.1.318.1.1.13.1.3.7.1.5
Enabling this OID will cause the system to enter a failure state if the high environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysLowEnvHum 1.3.6.1.4.1.318.1.1.13.1.3.7.1.6
Enabling this OID will cause the system to enter a failure state if the low environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysFireAlarm 1.3.6.1.4.1.318.1.1.13.1.3.7.1.7
Enabling this OID will cause the system to enter a failure state if the fire alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysSmokeAlarm 1.3.6.1.4.1.318.1.1.13.1.3.7.1.8
Enabling this OID will cause the system to enter a failure state if the smoke alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysCommLost 1.3.6.1.4.1.318.1.1.13.1.3.7.1.9
Enabling this OID will cause the system to enter a failure state if the system has lost comm. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysSupplySensorFail 1.3.6.1.4.1.318.1.1.13.1.3.7.1.10
Enabling this OID will cause the system to enter a failure state if the supply sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysReturnSensorFail 1.3.6.1.4.1.318.1.1.13.1.3.7.1.11
Enabling this OID will cause the system to enter a failure state if the return sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysPrimarySensorFail 1.3.6.1.4.1.318.1.1.13.1.3.7.1.12
Enabling this OID will cause the system to enter a failure state if the primary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysSecondarySensorFail 1.3.6.1.4.1.318.1.1.13.1.3.7.1.13
Enabling this OID will cause the system to enter a failure state if the secondary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverSysNoSensorsAvailable 1.3.6.1.4.1.318.1.1.13.1.3.7.1.14
Enabling this OID will cause the system to enter a failure state if no sensors are available. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverMod 1.3.6.1.4.1.318.1.1.13.1.3.7.2
OBJECT IDENTIFIER    

airFMGroupFailoverModMaintRequired 1.3.6.1.4.1.318.1.1.13.1.3.7.2.1
Enabling this OID will cause the system to enter a failure state if maintenance is required on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModCoolFail 1.3.6.1.4.1.318.1.1.13.1.3.7.2.2
Enabling this OID will cause the system to enter a failure state if cooling has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModHumFail 1.3.6.1.4.1.318.1.1.13.1.3.7.2.3
Enabling this OID will cause the system to enter a failure state if the humidifier has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModBlwrCntrl1Fail 1.3.6.1.4.1.318.1.1.13.1.3.7.2.4
Enabling this OID will cause the system to enter a failure state if blower controller 1 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModBlwrCntrl2Fail 1.3.6.1.4.1.318.1.1.13.1.3.7.2.5
Enabling this OID will cause the system to enter a failure state if blower controller 2 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModHighFilterDP 1.3.6.1.4.1.318.1.1.13.1.3.7.2.6
Enabling this OID will cause the system to enter a failure state if a high filter differential pressure is present on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModHighSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.3.7.2.7
Enabling this OID will cause the system to enter a failure state if a high supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModLowSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.3.7.2.8
Enabling this OID will cause the system to enter a failure state if a low supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModLossOrLowAirFlow 1.3.6.1.4.1.318.1.1.13.1.3.7.2.9
Enabling this OID will cause the system to enter a failure state if there is a loss of air flow or low air flow on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModHumReplaceCylinder 1.3.6.1.4.1.318.1.1.13.1.3.7.2.10
Enabling this OID will cause the system to enter a failure state if a humidifier needs its cylinder replaced on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModAirBlockInterlockOpen 1.3.6.1.4.1.318.1.1.13.1.3.7.2.11
Enabling this OID will cause the system to enter a failure state if the air block interlock is open on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModWaterDetected 1.3.6.1.4.1.318.1.1.13.1.3.7.2.12
Enabling this OID will cause the system to enter a failure state if water is detected by a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMGroupFailoverModCondensatePumpFail 1.3.6.1.4.1.318.1.1.13.1.3.7.2.13
Enabling this OID will cause the system to enter a failure state if the condensate pump has failed in a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

airFMSystem 1.3.6.1.4.1.318.1.1.13.1.4
OBJECT IDENTIFIER    

airFMSysStatus 1.3.6.1.4.1.318.1.1.13.1.4.1
OBJECT IDENTIFIER    

airFMSysNumber 1.3.6.1.4.1.318.1.1.13.1.4.1.1
The number of the system within the group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), one(2), two(3), three(4), four(5)  

airFMSysPresentStatus 1.3.6.1.4.1.318.1.1.13.1.4.1.2
The present mode of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), reserved1(2), reserved2(3), onLine(4), idle(5), loadShare(6), failed(7), offLine(8)  

airFMSysPresentRole 1.3.6.1.4.1.318.1.1.13.1.4.1.3
The present role of the System in the Group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), primary(2), backup(3)  

airFMSysRunHours 1.3.6.1.4.1.318.1.1.13.1.4.1.4
The total number of hours the System has been contributing to environmental control. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.5
The temperature of the coolant at the fluid coil inlet. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.6
The temperature of the coolant at the fluid coil inlet. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHotWaterTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.7
The hot water temperature. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHotWaterTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.8
The hot water temperature. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgReturnTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.9
The average return temperature calculated from all present modules. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgReturnTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.10
The average return temperature calculated from all present modules. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgReturnHum 1.3.6.1.4.1.318.1.1.13.1.4.1.11
The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgRemoteTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.12
The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgRemoteTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.13
The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysAvgRemoteHum 1.3.6.1.4.1.318.1.1.13.1.4.1.14
The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysMaxRemoteTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.15
The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysMaxRemoteTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.16
The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysMinRemoteTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.17
The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysMinRemoteTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.18
The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysTempCtrlMethod 1.3.6.1.4.1.318.1.1.13.1.4.1.19
The method of environment temperature control selected to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)  

airFMSysActualTempCtrlMethod 1.3.6.1.4.1.318.1.1.13.1.4.1.20
The actual method of environment temperature control being used to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)  

airFMSysHumCtrlMethod 1.3.6.1.4.1.318.1.1.13.1.4.1.21
The method of environment humidity control selected to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)  

airFMSysActualHumCtrlMethod 1.3.6.1.4.1.318.1.1.13.1.4.1.22
The actual method of environment humidity control being used to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)  

airFMSysCtrlTempC 1.3.6.1.4.1.318.1.1.13.1.4.1.23
The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCtrlTempF 1.3.6.1.4.1.318.1.1.13.1.4.1.24
The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCtrlHum 1.3.6.1.4.1.318.1.1.13.1.4.1.25
The system environmental control air humidity from the sensor denoted by airFMSysActualHumCtrl. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDemands 1.3.6.1.4.1.318.1.1.13.1.4.2
OBJECT IDENTIFIER    

airFMSysDXCoolingDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.1
The direct expansion cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDXDehumDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.2
The direct expansion dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDXActualCoolDehum 1.3.6.1.4.1.318.1.1.13.1.4.2.3
The direct expansion cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidCoolDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.4
The fluid coil cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidDehumDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.5
The fluid coil dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidActualCoolDehum 1.3.6.1.4.1.318.1.1.13.1.4.2.6
The fluid coil cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysElectricReheatDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.7
The electric reheating output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysActualElectricReheat 1.3.6.1.4.1.318.1.1.13.1.4.2.8
The electric reheating output of the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysSteamHotGasReheatDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.9
The steam, hot water, or hot gas reheating output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

airFMSysActualSteamHotGasReheat 1.3.6.1.4.1.318.1.1.13.1.4.2.10
The steam, hot water, or hot gas reheating output of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

airFMSysSteamElectrodeHumDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.11
The steam electrode humidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysActualSteamElectrodeHum 1.3.6.1.4.1.318.1.1.13.1.4.2.12
The average steam electrode humidification output measured for the Modules in the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysSteamHumDmd 1.3.6.1.4.1.318.1.1.13.1.4.2.13
The steam humidification output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

airFMSysActualSteamHum 1.3.6.1.4.1.318.1.1.13.1.4.2.14
The steam humidification output for the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

airFMSysSetup 1.3.6.1.4.1.318.1.1.13.1.4.3
OBJECT IDENTIFIER    

airFMSysNumModules 1.3.6.1.4.1.318.1.1.13.1.4.3.1
The number of Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), one(2), two(3), three(4)  

airFMSysNumPCIOMs 1.3.6.1.4.1.318.1.1.13.1.4.3.2
The number of Programmable Customer Input/Output Modules (PCIOMs) installed in the Main Module of this System. Each PCIOM adds four input contacts and four output relays to the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), one(2), two(3), three(4), four(5)  

airFMSysMainsVlt 1.3.6.1.4.1.318.1.1.13.1.4.3.3
The mains voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  DisplayString  

airFMSysUPSVlt 1.3.6.1.4.1.318.1.1.13.1.4.3.4
The UPS voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  DisplayString  

airFMSysCoilCfg 1.3.6.1.4.1.318.1.1.13.1.4.3.5
The type of cooling coils installed in the Modules in this System: DX coil, DX and MultiCool (chilled water) coils, DX and Economizer coils, or only a Chilled Liquid coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), dx(2), econ(3), multicool(4), chilledWater(5)  

airFMSysRefrigType 1.3.6.1.4.1.318.1.1.13.1.4.3.6
The type of refrigerant used by each compressor in the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), r22(2), r407C(3)  

airFMSysHeatRejection 1.3.6.1.4.1.318.1.1.13.1.4.3.7
The method the Modules in this System use to transfer heat away from the refrigerant. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), airCooled(2), waterCooled(3), glycolCooled(4)  

airFMSysDischAirPtrn 1.3.6.1.4.1.318.1.1.13.1.4.3.8
The discharge air pattern for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), upFlow(2), downFlow(3), horizFlow(4)  

airFMSysAirFltr 1.3.6.1.4.1.318.1.1.13.1.4.3.9
The type of air filters (standard or high efficiency) installed in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), standard(2), highEfficiency(3)  

airFMSysFlowSwitch 1.3.6.1.4.1.318.1.1.13.1.4.3.10
The location of the optional flow switch. None: No flow switch is installed in this System. DX: Coolant input to the heat exchanger (condenser). MultiCool: Chilled water input to the MultiCool coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), dxEcon(3), multiCoolChillWater(4)  

airFMSysCoilFluidVlvAct 1.3.6.1.4.1.318.1.1.13.1.4.3.11
The type of valve actuator installed on the coil fluid valve. The coil fluid valve controls the flow of coolant into a fluid cooling coil, such as a MultiCool or Economizer coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), springAnalog(3), floatingControl(4)  

airFMSysCoilFluidVlvType 1.3.6.1.4.1.318.1.1.13.1.4.3.12
The type of coil fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), twoWay(2), threeWay(3)  

airFMSysCndsrFluidVlvAct 1.3.6.1.4.1.318.1.1.13.1.4.3.13
The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) to regulate head pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), floatingControl(3)  

airFMSysCndsrFluidVlvType 1.3.6.1.4.1.318.1.1.13.1.4.3.14
The type of Condenser fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), twoWay(2), threeWay(3)  

airFMSysHotWaterVlvAct 1.3.6.1.4.1.318.1.1.13.1.4.3.15
The type of valve actuator installed on the hot water valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), springAnalog(3), floatingControl(4)  

airFMSysNumRemoteSensors 1.3.6.1.4.1.318.1.1.13.1.4.3.16
The number of remote sensors detected by the system.
OBJECT-TYPE    
  INTEGER  

airFMSysConfig 1.3.6.1.4.1.318.1.1.13.1.4.4
OBJECT IDENTIFIER    

airFMSysPrimaryControlSensor 1.3.6.1.4.1.318.1.1.13.1.4.4.1
Selects whether return or remote sensors will control the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), return(2), remote(3)  

airFMSysRemoteSensorData 1.3.6.1.4.1.318.1.1.13.1.4.4.2
Selects whether average temperature or max temperature will be used when remote sensors are selected for control of the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), average(2), maximum(3)  

airFMSysFastStartup 1.3.6.1.4.1.318.1.1.13.1.4.4.3
Minimizes the time for the cooling process to begin after other delay constraints have been met. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysStartupDelay 1.3.6.1.4.1.318.1.1.13.1.4.4.4
Set the delay that begins when power is applied and ends when the System starts. This allows you to create a staged restart among your Systems after a power loss. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysModeDelay 1.3.6.1.4.1.318.1.1.13.1.4.4.5
Set the delay between starting the blowers and engaging the modes. It allows the sensors to read room conditions accurately and allows the controller to check for major alarms before engaging a mode. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCommLossShutdownDelay 1.3.6.1.4.1.318.1.1.13.1.4.4.6
Set the delay between an Expansion Module losing communication with the Main Module and the Expansion Module shutting down. A value of -1 will keep the Expansion Module running after a communication loss. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysResetSysFailure 1.3.6.1.4.1.318.1.1.13.1.4.4.7
Setting this OID to reset(2) will allows the system to return from any failure condition, if the failure(s) have cleared. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMSysResetUserDflts 1.3.6.1.4.1.318.1.1.13.1.4.4.8
Setting this OID to reset(2) will reset all system parameters that can be edited by the user to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMSysResetFldSrvcDflts 1.3.6.1.4.1.318.1.1.13.1.4.4.9
Setting this OID to reset(2) will reset all system parameters that can only be edited by the field service engineer to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMSysResetRunHours 1.3.6.1.4.1.318.1.1.13.1.4.4.10
Setting this OID to reset(2) will reset the system Run Hours. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMSysCooling 1.3.6.1.4.1.318.1.1.13.1.4.5
OBJECT IDENTIFIER    

airFMSysCompMinOnTime 1.3.6.1.4.1.318.1.1.13.1.4.5.1
Set the minimum time the compressor continues to operate after it is started. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCompMinOffTime 1.3.6.1.4.1.318.1.1.13.1.4.5.2
Set the minimum time the compressor will remain off after it ceases operation. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCompRotPeriod 1.3.6.1.4.1.318.1.1.13.1.4.5.3
Set how often to perform compressor runtime balancing. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysEconIsolVlvOpenDelay 1.3.6.1.4.1.318.1.1.13.1.4.5.4
Set the delay between opening the Economizer Isolator output relay and engaging the compressors. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysEconIsolVlvCloseDelay 1.3.6.1.4.1.318.1.1.13.1.4.5.5
Set the delay between disengaging the compressor and closing the Economizer Isolator output relay. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCndsrFluidVlvCloseDelay 1.3.6.1.4.1.318.1.1.13.1.4.5.6
Set the time the condenser valve remains open after the compressors disengage. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysInterstageDelay 1.3.6.1.4.1.318.1.1.13.1.4.5.7
The DX interstage delay allows the first compressor's cooling to take effect before engaging the second compressor. This prevents the second compressor from cycling on and off excessively. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolState 1.3.6.1.4.1.318.1.1.13.1.4.5.8
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysCoolEssFunction 1.3.6.1.4.1.318.1.1.13.1.4.5.9
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), yes(2), no(3)  

airFMSysCoolSetpointC 1.3.6.1.4.1.318.1.1.13.1.4.5.10
The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolSetpointF 1.3.6.1.4.1.318.1.1.13.1.4.5.11
The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolDeadbandC 1.3.6.1.4.1.318.1.1.13.1.4.5.12
The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolDeadbandF 1.3.6.1.4.1.318.1.1.13.1.4.5.13
The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolEconIsolFunction 1.3.6.1.4.1.318.1.1.13.1.4.5.14
Set the Economizer Automatic Coolant Isolation valve to enabled or disabled. This valve anticipates a cooling demand and opens the coil fluid valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysSuctPresCompensation 1.3.6.1.4.1.318.1.1.13.1.4.5.15
Set the Suction Pressure Compensation to enabled or disabled. This function attempts to keep the suction pressure from exceeding 95 psi. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysCoilFluidActivThreshC 1.3.6.1.4.1.318.1.1.13.1.4.5.16
The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidActivThreshF 1.3.6.1.4.1.318.1.1.13.1.4.5.17
The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidActivDeadbandC 1.3.6.1.4.1.318.1.1.13.1.4.5.18
The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoilFluidActivDeadbandF 1.3.6.1.4.1.318.1.1.13.1.4.5.19
The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolPIDMethod 1.3.6.1.4.1.318.1.1.13.1.4.5.20
Set the multipliers that the PID algorithm will use to calculate the cool output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), p(2), pi(3), pid(4)  

airFMSysCoolPIDGainP 1.3.6.1.4.1.318.1.1.13.1.4.5.21
Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolPIDResetRateI 1.3.6.1.4.1.318.1.1.13.1.4.5.22
Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysCoolPIDDerivativeD 1.3.6.1.4.1.318.1.1.13.1.4.5.23
Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHumidify 1.3.6.1.4.1.318.1.1.13.1.4.6
OBJECT IDENTIFIER    

airFMSysHumState 1.3.6.1.4.1.318.1.1.13.1.4.6.1
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysHumEssFunction 1.3.6.1.4.1.318.1.1.13.1.4.6.2
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), yes(2), no(3)  

airFMSysHumSetpoint 1.3.6.1.4.1.318.1.1.13.1.4.6.3
The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH below the dehumidification setpoint. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHumDeadband 1.3.6.1.4.1.318.1.1.13.1.4.6.4
The humidity range that controls output when the selected control sensor humidity is below the setpoint. At the top of this range, the humidification mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHumCtrlSetting 1.3.6.1.4.1.318.1.1.13.1.4.6.5
Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point method helps correct for hot spots near the selected control sensors. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), relativeHum(2), dewPoint(3)  

airFMSysActualHumCtrl 1.3.6.1.4.1.318.1.1.13.1.4.6.6
The humidity control method the system is using. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), relativeHum(2), dewPoint(3)  

airFMSysHumSensBand 1.3.6.1.4.1.318.1.1.13.1.4.6.7
The percentage of relative humidity below the setpoint at which the humidifier will output at 100% of capacity. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDehumidify 1.3.6.1.4.1.318.1.1.13.1.4.7
OBJECT IDENTIFIER    

airFMSysDehumState 1.3.6.1.4.1.318.1.1.13.1.4.7.1
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysDehumEssFunction 1.3.6.1.4.1.318.1.1.13.1.4.7.2
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), yes(2), no(3)  

airFMSysDehumSetpoint 1.3.6.1.4.1.318.1.1.13.1.4.7.3
The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH above the humidification setpoint if a humidifier is installed. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDehumDeadband 1.3.6.1.4.1.318.1.1.13.1.4.7.4
The humidity range above the setpoint at which the dehumidification mode will output at 100%. The deadband does not apply to PID controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDehumCapacity 1.3.6.1.4.1.318.1.1.13.1.4.7.5
Set the dehumidification mode to use either half of the cooling coil or the full coil when dehumidifying the room. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), half(2), full(3)  

airFMSysDehumPIDMethod 1.3.6.1.4.1.318.1.1.13.1.4.7.6
Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), p(2), pi(3), pid(4)  

airFMSysDehumPIDGainP 1.3.6.1.4.1.318.1.1.13.1.4.7.7
Set the proportional multiplier to correct for differences between the selected control sensor actual humidity and the setpoint. Measured in %/%RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDehumPIDResetRateI 1.3.6.1.4.1.318.1.1.13.1.4.7.8
Set the integral multiplier to correct for the proportional offset. Measured in %/(%RH * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysDehumPIDDerivativeD 1.3.6.1.4.1.318.1.1.13.1.4.7.9
Set the derivative multiplier to counteract overshoot and droop during changes in the room humidity. Measure in %/(%RH / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheat 1.3.6.1.4.1.318.1.1.13.1.4.8
OBJECT IDENTIFIER    

airFMSysReheatState 1.3.6.1.4.1.318.1.1.13.1.4.8.1
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysReheatEssFunction 1.3.6.1.4.1.318.1.1.13.1.4.8.2
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), yes(2), no(3)  

airFMSysReheatSetpointC 1.3.6.1.4.1.318.1.1.13.1.4.8.3
The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatSetpointF 1.3.6.1.4.1.318.1.1.13.1.4.8.4
The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatDeadbandC 1.3.6.1.4.1.318.1.1.13.1.4.8.5
The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatDeadbandF 1.3.6.1.4.1.318.1.1.13.1.4.8.6
The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatPIDMethod 1.3.6.1.4.1.318.1.1.13.1.4.8.7
Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), p(2), pi(3), pid(4)  

airFMSysReheatPIDGainP 1.3.6.1.4.1.318.1.1.13.1.4.8.8
Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatPIDResetRateI 1.3.6.1.4.1.318.1.1.13.1.4.8.9
Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysReheatPIDDerivativeD 1.3.6.1.4.1.318.1.1.13.1.4.8.10
Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysThresholds 1.3.6.1.4.1.318.1.1.13.1.4.9
OBJECT IDENTIFIER    

airFMSysHighSplyTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.1
The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighSplyTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.2
The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowSplyTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.3
The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowSplyTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.4
The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighCoilFluidTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.5
The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighCoilFluidTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.6
The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowCoilFluidTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.7
The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowCoilFluidTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.8
The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighCtrlTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.9
The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighCtrlTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.10
The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowCtrlTempC 1.3.6.1.4.1.318.1.1.13.1.4.9.11
The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowCtrlTempF 1.3.6.1.4.1.318.1.1.13.1.4.9.12
The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHighCtrlHum 1.3.6.1.4.1.318.1.1.13.1.4.9.13
The high humidity threshold for air monitored by the System. If the humidity exceeds the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysLowCtrlHum 1.3.6.1.4.1.318.1.1.13.1.4.9.14
The low humidity threshold for air monitored by the System. If the humidity drops below the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysTempAlarmDelay 1.3.6.1.4.1.318.1.1.13.1.4.9.15
The amount of time the blower must be on before a temperature alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysHumAlarmDelay 1.3.6.1.4.1.318.1.1.13.1.4.9.16
The amount of time the blower must be on before a humidity alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMSysInputs 1.3.6.1.4.1.318.1.1.13.1.4.10
OBJECT IDENTIFIER    

airFMSysInputTableSize 1.3.6.1.4.1.318.1.1.13.1.4.10.1
The number of entries in the airFMSysInputTable.
OBJECT-TYPE    
  INTEGER  

airFMSysInputTable 1.3.6.1.4.1.318.1.1.13.1.4.10.2
Allows for getting information from each input contact.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysInputEntry

airFMSysInputEntry 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1
The input contact to obtain status from.
OBJECT-TYPE    
  AirFMSysInputEntry  

airFMSysInputIndex 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.1
The number designator of the Input Contact.
OBJECT-TYPE    
  INTEGER  

airFMSysInputName 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.2
The configurable name for the Input Contact. Maximum text input is 13 characters.
OBJECT-TYPE    
  DisplayString  

airFMSysInputStatus 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.3
The state of this contact: Open or Closed. A violation will occur when this relay is not in its normal state.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airFMSysInputNormalState 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.4
Set the normal state of this contact (the state when no alarm/event exists).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airFMSysInputDelay 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.5
Set the delay between this contact exiting its normal state and an alarm being triggered. Measured in seconds.
OBJECT-TYPE    
  INTEGER  

airFMSysInputAlarmAction 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.6
Sets the behavior for this contact when it exits its normal state.
OBJECT-TYPE    
  INTEGER statusOnly(1), minor(2), major(3), remoteRunStop(4), nonessStop(5), immShutdown(6)  

airFMSysOutputs 1.3.6.1.4.1.318.1.1.13.1.4.11
OBJECT IDENTIFIER    

airFMSysOutputTableSize 1.3.6.1.4.1.318.1.1.13.1.4.11.1
The number of entries in the airFMSysOutputTable.
OBJECT-TYPE    
  INTEGER  

airFMSysOutputTable 1.3.6.1.4.1.318.1.1.13.1.4.11.2
Allows for getting information from each output relay.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysOutputEntry

airFMSysOutputEntry 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1
The output relay to obtain status from.
OBJECT-TYPE    
  AirFMSysOutputEntry  

airFMSysOutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.1
The number designator of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysOutputStatus 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.2
The state of this relay: Open or Closed. A violation will occur when this relay is not in its normal state.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airFMSysOutputNormalState 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.3
Set the normal state of this relay (the state when no alarm/event exists).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airFMSysAlarmMap 1.3.6.1.4.1.318.1.1.13.1.4.12
OBJECT IDENTIFIER    

airFMSysAlarmMapSys 1.3.6.1.4.1.318.1.1.13.1.4.12.1
OBJECT IDENTIFIER    

airFMSysAlarmMapSysTableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.1.1
The number of entries in the airFMSysAlarmMapSysTable.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapSysTable 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapSysEntry

airFMSysAlarmMapSysEntry 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1
The system alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapSysEntry  

airFMSysAlarmMapSysOutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapSysAnyAlarm 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.2
System alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSystemOn 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.3
System alarm map setting for System On. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSystemOffline 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.4
System alarm map setting for System Offline. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysHighEnvTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.5
System alarm map setting for High Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysLowEnvTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.6
System alarm map setting for Low Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysHighEnvHum 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.7
System alarm map setting for High Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysLowEnvHum 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.8
System alarm map setting for Low Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysFireDet 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.9
System alarm map setting for Fire Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysSmokeDet 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.10
System alarm map setting for Smoke Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysEconIsol 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.11
System alarm map setting for Econ Isolator. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysSupplySensFail 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.12
System alarm map setting for Supply Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysReturnSensFail 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.13
System alarm map setting for Return Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysRemSensRemoved 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.14
System alarm map setting for Remote Sensor Removed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysPrimSensFail 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.15
System alarm map setting for Primary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysSecSensFail 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.16
System alarm map setting for Secondary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapSysSecSensActive 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.17
System alarm map setting for Secondary Sensor Active. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainMod 1.3.6.1.4.1.318.1.1.13.1.4.12.2
OBJECT IDENTIFIER    

airFMSysAlarmMapMainModTableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.2.1
The number of entries in the airFMSysAlarmMapMainModTable.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapMainModTable 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapMainModEntry

airFMSysAlarmMapMainModEntry 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1
The main module alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapMainModEntry  

airFMSysAlarmMapMainModOutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapMainModAnyAlarm 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.2
Main Module alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModMaintReq 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.3
Main Module alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModCoolFail 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.4
Main Module alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModHighSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.5
Main Module alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModLowSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.6
Main Module alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModHumFail 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.7
Main Module alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModHumReplCyl 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.8
Main Module alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModCondPumpFail 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.9
Main Module alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModBlwrCntl1Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.10
Main Module alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModBlwrCntl2Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.11
Main Module alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModHighFltrDP 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.12
Main Module alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModLowAirFlow 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.13
Main Module alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModAirBlckIntOpen 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.14
Main Module alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapMainModWaterDetected 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.15
Main Module alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1 1.3.6.1.4.1.318.1.1.13.1.4.12.3
OBJECT IDENTIFIER    

airFMSysAlarmMapExpMod1TableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.3.1
The number of entries in the airFMSysAlarmMapExpMod1Table.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapExpMod1Table 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapExpMod1Entry

airFMSysAlarmMapExpMod1Entry 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1
The expansion module 1 alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapExpMod1Entry  

airFMSysAlarmMapExpMod1OutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapExpMod1AnyAlarm 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.2
Exp Module 1 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1MaintReq 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.3
Exp Module 1 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1CoolFail 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.4
Exp Module 1 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1HighSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.5
Exp Module 1 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1LowSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.6
Exp Module 1 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1HumFail 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.7
Exp Module 1 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1HumReplCyl 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.8
Exp Module 1 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1CondPumpFail 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.9
Exp Module 1 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1BlwrCntl1Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.10
Exp Module 1 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1BlwrCntl2Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.11
Exp Module 1 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1HighFltrDP 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.12
Exp Module 1 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1LowAirFlow 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.13
Exp Module 1 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1AirBlckIntOpen 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.14
Exp Module 1 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod1WaterDetected 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.15
Exp Module 1 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2 1.3.6.1.4.1.318.1.1.13.1.4.12.4
OBJECT IDENTIFIER    

airFMSysAlarmMapExpMod2TableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.4.1
The number of entries in the airFMSysAlarmMapExpMod2Table.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapExpMod2Table 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapExpMod2Entry

airFMSysAlarmMapExpMod2Entry 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1
The expansion module 2 alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapExpMod2Entry  

airFMSysAlarmMapExpMod2OutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapExpMod2AnyAlarm 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.2
Exp Module 2 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2MaintReq 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.3
Exp Module 2 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2CoolFail 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.4
Exp Module 2 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2HighSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.5
Exp Module 2 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2LowSupplyTemp 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.6
Exp Module 2 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2HumFail 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.7
Exp Module 2 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2HumReplCyl 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.8
Exp Module 2 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2CondPumpFail 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.9
Exp Module 2 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2BlwrCntl1Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.10
Exp Module 2 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2BlwrCntl2Fail 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.11
Exp Module 2 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2HighFltrDP 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.12
Exp Module 2 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2LowAirFlow 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.13
Exp Module 2 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2AirBlckIntOpen 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.14
Exp Module 2 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapExpMod2WaterDetected 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.15
Exp Module 2 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput 1.3.6.1.4.1.318.1.1.13.1.4.12.5
OBJECT IDENTIFIER    

airFMSysAlarmMapInputTableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.5.1
The number of entries in the airFMSysAlarmMapInputTable.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapInputTable 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapInputEntry

airFMSysAlarmMapInputEntry 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1
The input contact alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapInputEntry  

airFMSysAlarmMapInputOutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapInput1 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.2
Input contact 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput2 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.3
Input contact 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput3 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.4
Input contact 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput4 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.5
Input contact 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput5 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.6
Input contact 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput6 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.7
Input contact 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput7 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.8
Input contact 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput8 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.9
Input contact 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput9 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.10
Input contact 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput10 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.11
Input contact 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput11 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.12
Input contact 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput12 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.13
Input contact 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput13 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.14
Input contact 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput14 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.15
Input contact 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput15 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.16
Input contact 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapInput16 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.17
Input contact 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput 1.3.6.1.4.1.318.1.1.13.1.4.12.6
OBJECT IDENTIFIER    

airFMSysAlarmMapOutputTableSize 1.3.6.1.4.1.318.1.1.13.1.4.12.6.1
The number of entries in the airFMSysAlarmMapOutputTable.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapOutputTable 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2
Allows for getting alarm map information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMSysAlarmMapOutputEntry

airFMSysAlarmMapOutputEntry 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1
The input contact alarm map type to reference.
OBJECT-TYPE    
  AirFMSysAlarmMapOutputEntry  

airFMSysAlarmMapOutputIndex 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.1
The index of the output relay.
OBJECT-TYPE    
  INTEGER  

airFMSysAlarmMapOutput1 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.2
Output relay 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput2 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.3
Output relay 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput3 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.4
Output relay 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput4 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.5
Output relay 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput5 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.6
Output relay 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput6 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.7
Output relay 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput7 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.8
Output relay 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput8 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.9
Output relay 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput9 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.10
Output relay 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput10 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.11
Output relay 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput11 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.12
Output relay 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput12 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.13
Output relay 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput13 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.14
Output relay 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput14 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.15
Output relay 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput15 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.16
Output relay 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMSysAlarmMapOutput16 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.17
Output relay 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

airFMModule 1.3.6.1.4.1.318.1.1.13.1.5
OBJECT IDENTIFIER    

airFMModIdent 1.3.6.1.4.1.318.1.1.13.1.5.1
OBJECT IDENTIFIER    

airFMModIdentTableSize 1.3.6.1.4.1.318.1.1.13.1.5.1.1
The number of entries in the airFMModIdentTable.
OBJECT-TYPE    
  INTEGER  

airFMModIdentTable 1.3.6.1.4.1.318.1.1.13.1.5.1.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModIdentEntry

airFMModIdentEntry 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModIdentEntry  

airFMModIdentModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModModelNumber 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.2
Model number of the Module.
OBJECT-TYPE    
  DisplayString  

airFMModSerialNumber 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.3
Unique identification number for this Module.
OBJECT-TYPE    
  DisplayString  

airFMModManufactureDate 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.4
Date the Module was manufactured.
OBJECT-TYPE    
  DisplayString  

airFMModFirmwareRev 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.5
Revision number of the firmware installed on this Module.
OBJECT-TYPE    
  DisplayString  

airFMModHardwareRev 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.6
Revision number of the hardware installed on this Module.
OBJECT-TYPE    
  DisplayString  

airFMModStatus 1.3.6.1.4.1.318.1.1.13.1.5.2
OBJECT IDENTIFIER    

airFMModStatusTableSize 1.3.6.1.4.1.318.1.1.13.1.5.2.1
The number of entries in the airFMModStatusTable.
OBJECT-TYPE    
  INTEGER  

airFMModStatusTable 1.3.6.1.4.1.318.1.1.13.1.5.2.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModStatusEntry

airFMModStatusEntry 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModStatusEntry  

airFMModStatusModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModSupplyTempC 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.2
The temperature measured at the supply sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModSupplyTempF 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.3
The temperature measured at the supply sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModSupplyHum 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.4
The humidity measured at the supply sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModReturnTempC 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.5
The temperature measured at the return sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModReturnTempF 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.6
The temperature measured at the return sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModReturnHum 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.7
The humidity measured at the return sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModFilterDiffPresPa 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.8
The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModFilterDiffPresInWC 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.9
The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModCoilDiffPresPa 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.10
The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModCoilDiffPresInWC 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.11
The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModProperties 1.3.6.1.4.1.318.1.1.13.1.5.3
OBJECT IDENTIFIER    

airFMModPropTableSize 1.3.6.1.4.1.318.1.1.13.1.5.3.1
The number of entries in the airFMModPropTable.
OBJECT-TYPE    
  INTEGER  

airFMModPropTable 1.3.6.1.4.1.318.1.1.13.1.5.3.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModPropEntry

airFMModPropEntry 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModPropEntry  

airFMModPropModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModOutputCapacity 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2
The cooling capacity (in Kilowatts) of the displayed Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), kw45(2), kw35(3), kw40(4), kw50(5), kw80(6)  

airFMModCapacityCtrl 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3
The method used to load and unload the compressors. Tandem compressor Modules use two stages (one compressor each). Single compressor Modules use hot gas bypass. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), tandem(2), hotGasBypass(3)  

airFMModHeaterType 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4
The type of reheating device installed in this Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), electricSCR(3), steam(4), hotWaterOnOff(5), hotGasReheat(6), hotGasAndElectric(7), hotWaterProp(8)  

airFMModElectricHeaterType 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5
The type/capacity of the electric heater, if installed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), kw10(2), kw15(3)  

airFMModHumidifierType 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6
The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), steamElectrode(3), liveSteam(4)  

airFMModBlwrFreqSetting 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7
Frequency of the blower in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModNomCoilDiffPresPa 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8
The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModNomCoilDiffPresInWC 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9
The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModCondPump 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10
Indicates the presence of a condensate pump in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), notPresent(2), present(3)  

airFMModFireDetector 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11
Indicates the presence of a fire detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), notPresent(2), present(3)  

airFMModSmokeDetector 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12
Indicates the presence of a smoke detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), notPresent(2), present(3)  

airFMModWaterDetector 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13
Indicates the presence of a water leak detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), notPresent(2), present(3)  

airFMModCooling 1.3.6.1.4.1.318.1.1.13.1.5.4
OBJECT IDENTIFIER    

airFMModCoolTableSize 1.3.6.1.4.1.318.1.1.13.1.5.4.1
The number of entries in the airFMModCoolTable.
OBJECT-TYPE    
  INTEGER  

airFMModCoolTable 1.3.6.1.4.1.318.1.1.13.1.5.4.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModCoolEntry

airFMModCoolEntry 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModCoolEntry  

airFMModCoolModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModComp1 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.2
The status of compressor 1 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), off(3)  

airFMModComp2 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.3
The status of compressor 2 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), off(3)  

airFMModSuctPresKPa 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.4
The refrigerant pressure measured at the suction inlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModSuctPresPSI 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.5
The refrigerant pressure measured at the suction inlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModDischPresKPa 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.6
The refrigerant pressure measured at the discharge outlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModDischPresPSI 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.7
The refrigerant pressure measured at the discharge outlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModCondFluidVlvPos 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.8
The position of the condenser fluid valve. The valve regulates the flow of liquid coolant into the heat exchanger (condenser). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModCoilFluidVlvPos 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.9
The position of the coil fluid valve. The valve regulates the flow of liquid coolant in the fluid cooling coil (MultiCool, Economizer, or Chilled Water). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModHumidity 1.3.6.1.4.1.318.1.1.13.1.5.5
OBJECT IDENTIFIER    

airFMModHumTableSize 1.3.6.1.4.1.318.1.1.13.1.5.5.1
The number of entries in the airFMModHumTable.
OBJECT-TYPE    
  INTEGER  

airFMModHumTable 1.3.6.1.4.1.318.1.1.13.1.5.5.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModHumEntry

airFMModHumEntry 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModHumEntry  

airFMModHumModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModHumidifier 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.2
The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), steamElectrode(3), liveSteam(4)  

airFMModElectrodeCurrent 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.3
The current drawn by the electrodes of the steam cylinder humidifier. Measured in tenths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModHumActualOutput 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.4
The humidification output of an individual Module. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModWaterConductivity 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.5
The conductivity of the water in the humidifier cylinder. Measured in microSiemens per centimeter. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModHotWaterVlvPos 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.6
The position of the hot water valve. 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModStmElectHumMode 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.7
Set the humidifier function mode. Off: Remove power from electrodes. Auto: Humidifier controlled by Module controller. Drain: Remove power from electrodes and drain the cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), auto(3), drain(4)  

airFMModBlower1 1.3.6.1.4.1.318.1.1.13.1.5.6
OBJECT IDENTIFIER    

airFMModBlwr1TableSize 1.3.6.1.4.1.318.1.1.13.1.5.6.1
The number of entries in the airFMModBlwr1Table.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1Table 1.3.6.1.4.1.318.1.1.13.1.5.6.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModBlwr1Entry

airFMModBlwr1Entry 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModBlwr1Entry  

airFMModBlwr1ModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1CtrlType 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.2
The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)  

airFMModBlwr1CmdFreq 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.3
The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ActFreq 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.4
The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1Poles 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.5
The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1RatedHorsePower 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.6
The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1RatedCurrent 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.7
The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ActTorq 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.8
The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1Current 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.9
The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1Vlt 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.10
The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1DCLinkVlt 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.11
The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1AccTime 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.12
The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1DecTime 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.13
The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1CapLife 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.14
The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1CtrlCoolFanLife 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.15
The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ElOvMode 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.16
Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), inactive(2), active(3)  

airFMModBlwr1ElOvSetting 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.17
The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ElOvTimeConst 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.18
The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1FanPower 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.19
The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1HeatsinkTempC 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.20
The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1HeatsinkTempF 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.21
The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ChokeTempC 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.22
The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1ChokeTempF 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.23
The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1InverterTempC 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.24
The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr1InverterTempF 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.25
The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlower2 1.3.6.1.4.1.318.1.1.13.1.5.7
OBJECT IDENTIFIER    

airFMModBlwr2TableSize 1.3.6.1.4.1.318.1.1.13.1.5.7.1
The number of entries in the airFMModBlwr2Table.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2Table 1.3.6.1.4.1.318.1.1.13.1.5.7.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModBlwr2Entry

airFMModBlwr2Entry 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModBlwr2Entry  

airFMModBlwr2ModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2CtrlType 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2
The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)  

airFMModBlwr2CmdFreq 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.3
The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ActFreq 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4
The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2Poles 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5
The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2RatedHorsePower 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6
The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2RatedCurrent 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7
The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ActTorq 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8
The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2Current 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9
The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2Vlt 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10
The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2DCLinkVlt 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11
The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2AccTime 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12
The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2DecTime 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13
The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2CapLife 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14
The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2CtrlCoolFanLife 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15
The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ElOvMode 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16
Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), inactive(2), active(3)  

airFMModBlwr2ElOvSetting 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17
The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ElOvTimeConst 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18
The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2FanPower 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19
The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2HeatsinkTempC 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20
The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2HeatsinkTempF 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21
The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ChokeTempC 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22
The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2ChokeTempF 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23
The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2InverterTempC 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24
The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModBlwr2InverterTempF 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25
The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRunHours 1.3.6.1.4.1.318.1.1.13.1.5.8
OBJECT IDENTIFIER    

airFMModRHTableSize 1.3.6.1.4.1.318.1.1.13.1.5.8.1
The number of entries in the airFMModRHTable.
OBJECT-TYPE    
  INTEGER  

airFMModRHTable 1.3.6.1.4.1.318.1.1.13.1.5.8.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModRHEntry

airFMModRHEntry 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModRHEntry  

airFMModRHModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModRHComp1 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.2
Compressor 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHComp2 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.3
Compressor 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHHeater 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.4
Heater run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHHum 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.5
Humidifier run hours A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHBlwr1 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.6
Blower 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHBlwr2 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.7
Blower 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHBlwrCtrl1 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.8
Blower Controller 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHBlwrCtrl2 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.9
Blower Controller 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModRHComp1Reset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.10
Reset the compressor 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModRHComp2Reset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.11
Reset the compressor 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModRHHeaterReset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.12
Reset the heater run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModRHHumReset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.13
Reset the humidifier run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModRHBlwr1Reset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.14
Reset the blower 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModRHBlwr2Reset 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.15
Reset the blower 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntervals 1.3.6.1.4.1.318.1.1.13.1.5.9
OBJECT IDENTIFIER    

airFMModServIntComp1 1.3.6.1.4.1.318.1.1.13.1.5.9.1
The interval at which to generate a maintenance alarm for compressor 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntComp2 1.3.6.1.4.1.318.1.1.13.1.5.9.2
The interval at which to generate a maintenance alarm for compressor 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntHeater 1.3.6.1.4.1.318.1.1.13.1.5.9.3
The interval at which to generate a maintenance alarm for the reheat components. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntHum 1.3.6.1.4.1.318.1.1.13.1.5.9.4
The interval at which to generate a maintenance alarm for the humidifier. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntBlwr1 1.3.6.1.4.1.318.1.1.13.1.5.9.5
The interval at which to generate a maintenance alarm for blower 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntBlwr2 1.3.6.1.4.1.318.1.1.13.1.5.9.6
The interval at which to generate a maintenance alarm for blower 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntBlwrCtrl1 1.3.6.1.4.1.318.1.1.13.1.5.9.7
The interval at which to generate a maintenance alarm for blower controller 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntBlwrCtrl2 1.3.6.1.4.1.318.1.1.13.1.5.9.8
The interval at which to generate a maintenance alarm for blower controller 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER  

airFMModServIntResets 1.3.6.1.4.1.318.1.1.13.1.5.10
OBJECT IDENTIFIER    

airFMModServIntResetTableSize 1.3.6.1.4.1.318.1.1.13.1.5.10.1
The number of entries in the airFMModServIntTable.
OBJECT-TYPE    
  INTEGER  

airFMModServIntResetTable 1.3.6.1.4.1.318.1.1.13.1.5.10.2
Allows for getting information from each module in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMModServIntResetEntry

airFMModServIntResetEntry 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1
The module to get information from.
OBJECT-TYPE    
  AirFMModServIntResetEntry  

airFMModServIntResetModuleIndex 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1
The index of the module.
OBJECT-TYPE    
  INTEGER  

airFMModServIntComp1Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2
Reset the compressor 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntComp2Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3
Reset the compressor 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntHeaterReset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4
Reset the heater service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntHumReset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5
Reset the humidifier service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntBlwr1Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6
Reset the blower 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntBlwr2Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7
Reset the blower 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntBlwrCtrl1Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8
Reset the blower controller 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMModServIntBlwrCtrl2Reset 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9
Reset the blower controller 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
OBJECT-TYPE    
  INTEGER notApplicable(1), noOperation(2), reset(3)  

airFMAlarms 1.3.6.1.4.1.318.1.1.13.1.6
OBJECT IDENTIFIER    

airFMAlarmClearActiveGroupAlarms 1.3.6.1.4.1.318.1.1.13.1.6.1
Clear active group alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value.
OBJECT-TYPE    
  INTEGER noOperation(1), clearAlarms(2)  

airFMAlarmClearActiveSysModAlarms 1.3.6.1.4.1.318.1.1.13.1.6.2
Clear active system and module alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value.
OBJECT-TYPE    
  INTEGER noOperation(1), clearAlarms(2)  

airFMAlarmConditionsTableSize 1.3.6.1.4.1.318.1.1.13.1.6.3
The number of active alarm conditions in the airFMAlarmConditionTable.
OBJECT-TYPE    
  INTEGER  

airFMAlarmConditionsTable 1.3.6.1.4.1.318.1.1.13.1.6.4
Table of active alarm conditions for the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AirFMAlarmConditionsEntry

airFMAlarmConditionsEntry 1.3.6.1.4.1.318.1.1.13.1.6.4.1
Alarm condition specification
OBJECT-TYPE    
  AirFMAlarmConditionsEntry  

airFMAlarmConditionsIndex 1.3.6.1.4.1.318.1.1.13.1.6.4.1.1
Alarm condition index.
OBJECT-TYPE    
  INTEGER  

airFMAlarmSeverity 1.3.6.1.4.1.318.1.1.13.1.6.4.1.2
Severity of the alarm.
OBJECT-TYPE    
  INTEGER informational(1), warningMinor(2), criticalMajor(3)  

airFMAlarmType 1.3.6.1.4.1.318.1.1.13.1.6.4.1.3
Type of alarm.
OBJECT-TYPE    
  INTEGER group(1), system(2), mainMod(3), expMod1(4), expMod2(5)  

airFMEventCode 1.3.6.1.4.1.318.1.1.13.1.6.4.1.4
APC event code for the alarm.
OBJECT-TYPE    
  INTEGER  

airFMAlarmDate 1.3.6.1.4.1.318.1.1.13.1.6.4.1.5
Date the alarm was recorded.
OBJECT-TYPE    
  DisplayString  

airFMAlarmTime 1.3.6.1.4.1.318.1.1.13.1.6.4.1.6
Time the alarm was recorded.
OBJECT-TYPE    
  DisplayString  

airFMAlarmDescription 1.3.6.1.4.1.318.1.1.13.1.6.4.1.7
Description of the alarm.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

airPA 1.3.6.1.4.1.318.1.1.13.2
OBJECT IDENTIFIER    

airPAIdent 1.3.6.1.4.1.318.1.1.13.2.1
OBJECT IDENTIFIER    

airPAIdentName 1.3.6.1.4.1.318.1.1.13.2.1.1
A character string identifying the device name.
OBJECT-TYPE    
  DisplayString  

airPAModelNumber 1.3.6.1.4.1.318.1.1.13.2.1.2
A character string identifying the device model number.
OBJECT-TYPE    
  DisplayString  

airPADateOfManufacture 1.3.6.1.4.1.318.1.1.13.2.1.3
A character string identifying when the device was produced.
OBJECT-TYPE    
  DisplayString  

airPASerialNumber 1.3.6.1.4.1.318.1.1.13.2.1.4
A character string identifying the device serial number.
OBJECT-TYPE    
  DisplayString  

airPAFirmwareRevision 1.3.6.1.4.1.318.1.1.13.2.1.5
A character string identifying the device firmware revision.
OBJECT-TYPE    
  DisplayString  

airPAHardwareRevision 1.3.6.1.4.1.318.1.1.13.2.1.6
A character string identifying the device hardware revision.
OBJECT-TYPE    
  DisplayString  

airPAStatus 1.3.6.1.4.1.318.1.1.13.2.2
OBJECT IDENTIFIER    

airPASystemPower 1.3.6.1.4.1.318.1.1.13.2.2.1
The status of the unit's system power setting. ON(1) The system power is turned on. OFF(2) The system power is turned off.
OBJECT-TYPE    
  INTEGER powerON(1), powerOFF(2)  

airPAOperatingMode 1.3.6.1.4.1.318.1.1.13.2.2.2
The current operating mode of the unit. OFF(1) The system is off. VENTING(2) The system's venting function is active. COOLING(3) The system's cooling function is active.
OBJECT-TYPE    
  INTEGER modeOFF(1), modeVENTING(2), modeCOOLING(3)  

airPASetpointTempF 1.3.6.1.4.1.318.1.1.13.2.2.3
The temperature setpoint in Fahrenheit to which the unit is controlling.
OBJECT-TYPE    
  INTEGER  

airPASetpointTempC 1.3.6.1.4.1.318.1.1.13.2.2.4
The temperature setpoint in Celsius to which the unity is controlling.
OBJECT-TYPE    
  INTEGER  

airPABlowerSpeed 1.3.6.1.4.1.318.1.1.13.2.2.5
The unit's blower speed setting. LOW(1) The blower speed is low. HIGH(2) The blower speed is high.
OBJECT-TYPE    
  INTEGER speedLOW(1), speedHIGH(2)  

airPACompressor 1.3.6.1.4.1.318.1.1.13.2.2.6
The unit's compressor status. ON(1) The compressor is turned on. OFF(2) The compressor is turned off.
OBJECT-TYPE    
  INTEGER statusON(1), statusOFF(2)  

airPACondenserFan 1.3.6.1.4.1.318.1.1.13.2.2.7
The unit's condenser fan status. ON(1) The condenser fan is turned on. OFF(2) The condenser fan is turned off.
OBJECT-TYPE    
  INTEGER statusON(1), statusOFF(2)  

airPACondensatePump 1.3.6.1.4.1.318.1.1.13.2.2.8
The unit's condensate pump status. ON(1) The condensate pump is turned on. OFF(2) The condensate pump is turned off.
OBJECT-TYPE    
  INTEGER statusON(1), statusOFF(2)  

airPASupplyTempF 1.3.6.1.4.1.318.1.1.13.2.2.9
The supply temperature in degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airPASupplyTempC 1.3.6.1.4.1.318.1.1.13.2.2.10
The supply temperature in degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airPAReturnTempF 1.3.6.1.4.1.318.1.1.13.2.2.11
The return temperature in degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airPAReturnTempC 1.3.6.1.4.1.318.1.1.13.2.2.12
The return temperature in degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airPARemoteTempF 1.3.6.1.4.1.318.1.1.13.2.2.13
The remote temperature in degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airPARemoteTempC 1.3.6.1.4.1.318.1.1.13.2.2.14
The remote temperature in degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airPARemoteHumidity 1.3.6.1.4.1.318.1.1.13.2.2.15
The remote humidity.
OBJECT-TYPE    
  INTEGER  

airIR 1.3.6.1.4.1.318.1.1.13.3
OBJECT IDENTIFIER    

airIRAlarms 1.3.6.1.4.1.318.1.1.13.3.1
OBJECT IDENTIFIER    

airIRAlarmConditionsTableSize 1.3.6.1.4.1.318.1.1.13.3.1.1
The number of active alarm conditions in the airIRAlarmConditionTable.
OBJECT-TYPE    
  INTEGER  

airIRAlarmConditionsTable 1.3.6.1.4.1.318.1.1.13.3.1.2
Table of active alarm conditions for the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRAlarmConditionsEntry

airIRAlarmConditionsEntry 1.3.6.1.4.1.318.1.1.13.3.1.2.1
Alarm condition specification
OBJECT-TYPE    
  AirIRAlarmConditionsEntry  

airIRAlarmConditionsIndex 1.3.6.1.4.1.318.1.1.13.3.1.2.1.1
Alarm condition index.
OBJECT-TYPE    
  INTEGER  

airIREventCode 1.3.6.1.4.1.318.1.1.13.3.1.2.1.2
Code for the alarm.
OBJECT-TYPE    
  INTEGER  

airIRAlarmDescription 1.3.6.1.4.1.318.1.1.13.3.1.2.1.3
Description of the alarm.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

airIRRC 1.3.6.1.4.1.318.1.1.13.3.2
OBJECT IDENTIFIER    

airIRRCGroup 1.3.6.1.4.1.318.1.1.13.3.2.1
OBJECT IDENTIFIER    

airIRRCGroupStatus 1.3.6.1.4.1.318.1.1.13.3.2.1.1
OBJECT IDENTIFIER    

airIRRCGroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.2.1.1.1
Group coolant output in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.2.1.1.2
Group coolant demand in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.2.1.1.3
Group air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.2.1.1.4
Group air flow in liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.2.1.1.5
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.1.1.6
Group maximum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.2.1.1.7
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.1.1.8
Group minimum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupSetpoints 1.3.6.1.4.1.318.1.1.13.3.2.1.2
OBJECT IDENTIFIER    

airIRRCGroupSetpointsCoolUS 1.3.6.1.4.1.318.1.1.13.3.2.1.2.1
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupSetpointsCoolMetric 1.3.6.1.4.1.318.1.1.13.3.2.1.2.2
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupSetpointsSupplyAirUS 1.3.6.1.4.1.318.1.1.13.3.2.1.2.3
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupSetpointsSupplyAirMetric 1.3.6.1.4.1.318.1.1.13.3.2.1.2.4
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupSetpointsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.3.2.1.2.5
The preferred fan speed setting.
OBJECT-TYPE    
  INTEGER low(1), med-low(2), med(3), med-high(4), high(5)  

airIRRCGroupSetpointsFanSpeedControl 1.3.6.1.4.1.318.1.1.13.3.2.1.2.6
The fan speed control setting. Automatic(1) - controller manages fan speed. Manual(2) - fan speed is fixed and set by the fan speed preference. See airIRRCGroupSetpointsFanSpeedPreference.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRRCGroupConfig 1.3.6.1.4.1.318.1.1.13.3.2.1.3
OBJECT IDENTIFIER    

airIRRCGroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.3.2.1.3.1
The number of cooling units present in the group.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.3.2.1.3.2
The group configuration type.
OBJECT-TYPE    
  INTEGER racs(1), hacs(2), in-row(3), cacs(4)  

airIRRCGroupConfigPctGlycol 1.3.6.1.4.1.318.1.1.13.3.2.1.3.3
The glycol mixture in percent.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupConfigCoolGainP 1.3.6.1.4.1.318.1.1.13.3.2.1.3.4
The gain component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupConfigCoolResetRateI 1.3.6.1.4.1.318.1.1.13.3.2.1.3.5
The integral component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupConfigCoolDerivativeD 1.3.6.1.4.1.318.1.1.13.3.2.1.3.6
The derivative component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRCGroupConfigMaxFanSpeed 1.3.6.1.4.1.318.1.1.13.3.2.1.3.7
The maximum desired fan speed setting in percent.
OBJECT-TYPE    
  INTEGER  

airIRRCUnit 1.3.6.1.4.1.318.1.1.13.3.2.2
OBJECT IDENTIFIER    

airIRRCUnitIdent 1.3.6.1.4.1.318.1.1.13.3.2.2.1
OBJECT IDENTIFIER    

airIRRCUnitIdentID 1.3.6.1.4.1.318.1.1.13.3.2.2.1.1
The unit identification number.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitIdentName 1.3.6.1.4.1.318.1.1.13.3.2.2.1.2
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentLocation 1.3.6.1.4.1.318.1.1.13.3.2.2.1.3
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentModelNumber 1.3.6.1.4.1.318.1.1.13.3.2.2.1.4
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentSerialNumber 1.3.6.1.4.1.318.1.1.13.3.2.2.1.5
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.3.2.2.1.6
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.3.2.2.1.7
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitIdentManufactureDate 1.3.6.1.4.1.318.1.1.13.3.2.2.1.8
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRRCUnitStatus 1.3.6.1.4.1.318.1.1.13.3.2.2.2
OBJECT IDENTIFIER    

airIRRCUnitStatusOperateMode 1.3.6.1.4.1.318.1.1.13.3.2.2.2.1
The cooling unit operating mode.
OBJECT-TYPE    
  INTEGER standby(1), on(2), idle(3)  

airIRRCUnitStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.2.2.2.2
The unit cooling output in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.2.2.2.3
The unit cooling demand in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.4
The unit air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.5
The unit air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.6
The unit rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.7
The unit rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusSupplyAirTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.8
The unit supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusSupplyAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.9
The unit supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.10
The unit return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.11
The unit return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusContainmtDPUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.12
The unit containment differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusContainmtDPMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.13
The unit containment differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusFilterDPUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.14
The unit air filter differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusFilterDPMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.15
The unit air filter differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusFanSpeed 1.3.6.1.4.1.318.1.1.13.3.2.2.2.16
The unit average fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusInputState 1.3.6.1.4.1.318.1.1.13.3.2.2.2.17
The state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRCUnitStatusOutputState 1.3.6.1.4.1.318.1.1.13.3.2.2.2.18
The state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRCUnitStatusActivePowerSource 1.3.6.1.4.1.318.1.1.13.3.2.2.2.19
The power source that is powering the unit.
OBJECT-TYPE    
  INTEGER sourceA(1), sourceB(2)  

airIRRCUnitStatusFluidValvePosition 1.3.6.1.4.1.318.1.1.13.3.2.2.2.20
The fluid valve position in percent open.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusFluidFlowUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.21
The fluid flow in tenths of gallons per minute.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusFluidFlowMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.22
The fluid flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusEnteringFluidTemperatureUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.23
The temperature of the entering fluid in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusEnteringFluidTemperatureMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.24
The temperature of the entering fluid in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusLeavingFluidTemperatureUS 1.3.6.1.4.1.318.1.1.13.3.2.2.2.25
The temperature of the Leaving fluid in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitStatusLeavingFluidTemperatureMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.2.26
The temperature of the Leaving fluid in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHours 1.3.6.1.4.1.318.1.1.13.3.2.2.3
OBJECT IDENTIFIER    

airIRRCUnitRunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.3.2.2.3.1
Unit air filter run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan1 1.3.6.1.4.1.318.1.1.13.3.2.2.3.2
Unit fan 1 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan2 1.3.6.1.4.1.318.1.1.13.3.2.2.3.3
Unit fan 2 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan3 1.3.6.1.4.1.318.1.1.13.3.2.2.3.4
Unit fan 3 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan4 1.3.6.1.4.1.318.1.1.13.3.2.2.3.5
Unit fan 4 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan5 1.3.6.1.4.1.318.1.1.13.3.2.2.3.6
Unit fan 5 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan6 1.3.6.1.4.1.318.1.1.13.3.2.2.3.7
Unit fan 6 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan7 1.3.6.1.4.1.318.1.1.13.3.2.2.3.8
Unit fan 7 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFan8 1.3.6.1.4.1.318.1.1.13.3.2.2.3.9
Unit fan 8 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFanPowerSupplyLeft 1.3.6.1.4.1.318.1.1.13.3.2.2.3.10
Unit fan left power supply run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursFanPowerSupplyRight 1.3.6.1.4.1.318.1.1.13.3.2.2.3.11
Unit fan right power supply run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitRunHoursCondensatePump 1.3.6.1.4.1.318.1.1.13.3.2.2.3.12
Unit condensate pump run hours.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitServiceIntervals 1.3.6.1.4.1.318.1.1.13.3.2.2.4
OBJECT IDENTIFIER    

airIRRCUnitServiceIntervalsAirFilter 1.3.6.1.4.1.318.1.1.13.3.2.2.4.1
Air filter service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitServiceIntervalsAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.3.2.2.4.2
The air filter service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRCUnitThresholds 1.3.6.1.4.1.318.1.1.13.3.2.2.5
OBJECT IDENTIFIER    

airIRRCUnitThresholdsRackInletHighTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.5.1
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsRackInletHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.5.2
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsSupplyAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.5.3
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsSupplyAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.5.4
Unit supply air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsReturnAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.5.5
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsReturnAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.5.6
Unit return air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsEnteringFluidHighTempUS 1.3.6.1.4.1.318.1.1.13.3.2.2.5.7
Unit entering fluid high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitThresholdsEnteringFluidHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.2.2.5.8
Unit incoming fluid high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitConfig 1.3.6.1.4.1.318.1.1.13.3.2.2.6
OBJECT IDENTIFIER    

airIRRCUnitConfigCoolCapacity 1.3.6.1.4.1.318.1.1.13.3.2.2.6.1
The cooling capacity options setting.
OBJECT-TYPE    
  INTEGER automatic(1), maximum(2)  

airIRRCUnitConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.3.2.2.6.2
The startup delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRRCUnitConfigIdleOnLeakDetect 1.3.6.1.4.1.318.1.1.13.3.2.2.6.3
The idle on leak options setting.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRRCUnitConfigPowerSource 1.3.6.1.4.1.318.1.1.13.3.2.2.6.4
The configured power source of the unit.
OBJECT-TYPE    
  INTEGER sourceA(1), sourceB(2), sourceAandB(3)  

airIRRCUnitConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.3.2.2.6.5
The normal state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRCUnitConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.3.2.2.6.6
The normal state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRCUnitConfigOutputSource 1.3.6.1.4.1.318.1.1.13.3.2.2.6.7
The source of output relay change.
OBJECT-TYPE    
  INTEGER anyAlarm(1), criticalAlarm(2)  

airIRRCUnitConfigIdleOnCoolFail 1.3.6.1.4.1.318.1.1.13.3.2.2.6.8
The idle on cool fail options setting. If yes, the system will go into idle mode when a cooling failure is detected. If no, the system will not go into idle mode when a cooling failure is detected.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRRP 1.3.6.1.4.1.318.1.1.13.3.3
OBJECT IDENTIFIER    

airIRRP100 1.3.6.1.4.1.318.1.1.13.3.3.1
OBJECT IDENTIFIER    

airIRRP100Group 1.3.6.1.4.1.318.1.1.13.3.3.1.1
OBJECT IDENTIFIER    

airIRRP100GroupStatus 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1
OBJECT IDENTIFIER    

airIRRP100GroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.1
Group air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.2
Group air flow in liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.3
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.4
Group maximum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.5
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.6
Group minimum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.7
Group coolant demand in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.8
Group coolant output in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusHumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.9
The amount of humidification the group is demanding from the humidifiers in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusHumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.10
The actual amount of humidification the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusDehumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.11
The amount of dehumidification the group is demanding from the electric heaters in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusDehumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.12
The actual amount of dehumidification the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusReheatDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.13
The amount of heating the group is demanding from the electric heaters in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupStatusReheatOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.14
The actual amount of heating the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpoints 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2
OBJECT IDENTIFIER    

airIRRP100GroupSetpointsCoolUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.1
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsCoolMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.2
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsSupplyAirUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.3
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsSupplyAirMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.4
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsHumidify 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.5
Group humidify setpoint in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsDehumidify 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.6
Group dehumidify setpoint in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsDehumidifyDeadband 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.7
Group dehumidify deadband in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsReheatUS 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.8
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsReheatMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.9
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupSetpointsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.10
The preferred fan speed setting.
OBJECT-TYPE    
  INTEGER low(1), med-low(2), med(3), med-high(4), high(5)  

airIRRP100GroupSetpointsFanSpeedControl 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.11
The fan speed control setting.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRRP100GroupConfig 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3
OBJECT IDENTIFIER    

airIRRP100GroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.1
The number of cooling units present in the group.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.2
The group configuration type.
OBJECT-TYPE    
  INTEGER racs(1), hacs(2), in-row(3)  

airIRRP100GroupConfigCoolGainP 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.3
The gain component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigCoolResetRateI 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.4
The integral component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigCoolDerivativeD 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.5
The derivative component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigHumidifySensitivityBand 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.6
The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigReheatGainP 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.7
The gain component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigReheatResetRateI 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.8
The integral component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigReheatDerivativeD 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.9
The derivative component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigNumberofBackupUnits 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.10
The number of backup units.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigRuntimeBalancingEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.11
Enable or disable runtime balancing feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRRP100GroupConfigLoadAssistEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.12
Enable or disable load assist feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRRP100GroupConfigFullRPBackups 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.13
The number of full featured RPs that can be used as backup units.
OBJECT-TYPE    
  INTEGER  

airIRRP100GroupConfigMaxFanSpeed 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.14
The maximum desired fan speed setting in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100Unit 1.3.6.1.4.1.318.1.1.13.3.3.1.2
OBJECT IDENTIFIER    

airIRRP100UnitIdent 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1
OBJECT IDENTIFIER    

airIRRP100UnitIdentID 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.1
The unit identification number.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitIdentName 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.2
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentLocation 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.3
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentModelNumber 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.4
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentSerialNumber 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.5
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.6
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.7
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitIdentManufactureDate 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.8
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRRP100UnitStatus 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2
OBJECT IDENTIFIER    

airIRRP100UnitStatusOperateMode 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1
The cooling unit operating mode.
OBJECT-TYPE    
  INTEGER standby(1), on(2), idle(3), prestart(4), service(5), backup(6), assist(7)  

airIRRP100UnitStatusRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.2
The unit rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3
The unit rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusSupplyAirTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.4
The unit supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusSupplyAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5
The unit supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.6
The unit return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7
The unit return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusSupplyHumidity 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8
The relative humidity of the supply air in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusReturnHumidity 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.9
The relative humidity of the return air in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.10
The unit air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11
The unit air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusFanSpeed 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12
The unit average fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13
The unit cooling demand in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14
The unit cooling output in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusHumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.15
The amount of humidification the unit is demanding from the humidifier in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusHumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.16
The actual humidification output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusDehumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.17
The amount of dehumidification the unit is demanding in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusDehumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.18
The actual dehumidification output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusReheatDemand 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.19
The amount of heating the unit is demanding from the electric heater in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusReheatOutput 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.20
The actual heating output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusInputState 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21
The state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP100UnitStatusOutputState 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22
The state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP100UnitStatusRackInletTemperature1US 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.23
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTemperature1Metric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTemperature2US 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.25
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTemperature2Metric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTemperature3US 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.27
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusRackInletTemperature3Metric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusFilterDPUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.29
The unit air filter differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusFilterDPMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.30
The unit air filter differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusContainmtDPUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.31
The unit containment differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusContainmtDPMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.32
The unit containment differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusHumidifierCurrent 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33
The humidifier current of the unit in amperes.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusHumidifierWaterConductivity 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.34
The water conductivity in the humidifier of the unit in microSiemens/cm.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveSpeed 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35
The compressor drive speed in hundredths of Hertz.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDrivePower 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.36
The compressor drive power consumption in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveVoltage 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37
The compressor drive voltage consumption in tenths of volts.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveCurrent 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38
The compressor drive voltage consumption in tenths of amperes.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveDCLinkVoltage 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39
The compressor drive DC link voltage in tenths of volts.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveHeatSinkTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.40
The temperature of the compressor drive heatsink in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41
The temperature of the compressor drive heatsink in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveControlCardTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.42
The temperature of the compressor drive control card in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveControlCardTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43
The temperature of the compressor drive control card in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveWarningStatus 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.44
The four byte warning status of the compressor drive in hexadecimal.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusCompressorDriveAlarmStatus 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.45
The four byte alarm status of the compressor drive in hexadecimal.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusSuctionPressureUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.46
Unit suction pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusSuctionPressureMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.47
Unit suction pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusDischargePressureUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.48
Unit discharge pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitStatusDischargePressureMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.49
Unit discharge pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHours 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3
OBJECT IDENTIFIER    

airIRRP100UnitRunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.1
Unit air filter run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursCondensatePump 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.2
Unit condensate pump run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursHumidifier 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.3
Unit fan right power supply run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursFan1 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.4
Unit fan 1 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursHeater1 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.5
Unit heater 1 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursFan2 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.6
Unit fan 2 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursHeater2 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.7
Unit Heater 2 run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursCompressor 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.8
Unit compressor run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitRunHoursSystem 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.9
Total system run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervals 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4
OBJECT IDENTIFIER    

airIRRP100UnitServiceIntervalAirFilter 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.1
Air filter service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.2
The air filter service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitServiceIntervalHumidifier 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.3
Humidifier service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalHumidifierAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.4
The humidifier service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitServiceIntervalHeater 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.5
Heater service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalHeaterAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.6
The heater service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitServiceIntervalCompressor 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.7
Compressor service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalCompressorAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.8
The compressor service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitServiceIntervalCondensatePump 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.9
Condensate pump service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalCondensatePumpAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.10
The condensate pump service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitServiceIntervalFans 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.11
Fans service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitServiceIntervalFansAlarm 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.12
The fans service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitThresholds 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5
OBJECT IDENTIFIER    

airIRRP100UnitThresholdsRackInletHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.1
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsRackInletHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.2
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsSupplyAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.3
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsSupplyAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.4
Unit supply air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsReturnAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.5
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsReturnAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.6
Unit return air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsSupplyHumidityHigh 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.7
Unit supply humidity high threshold in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitThresholdsSupplyHumidityLow 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.8
Unit supply humidity low threshold in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitConfig 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6
OBJECT IDENTIFIER    

airIRRP100UnitConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1
The startup delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRRP100UnitConfigCoolCapacity 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.2
The cooling capacity options setting.
OBJECT-TYPE    
  INTEGER automatic(1), maximum(2)  

airIRRP100UnitConfigIdleOnLeakDetect 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.3
The idle on leak options setting.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRRP100UnitConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.4
The normal state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP100UnitConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.5
The normal state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP100UnitConfigOutputSource 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.6
The source of output relay change.
OBJECT-TYPE    
  INTEGER anyAlarm(1), criticalAlarm(2)  

airIRRP100UnitConfigHumidifyEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.7
Enable/disable humidification.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitConfigHumidifierControl 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.8
The humidifier drain control.
OBJECT-TYPE    
  INTEGER auto(1), drainOff(2)  

airIRRP100UnitConfigDehumidifyEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.9
Enable/disable dehumidification.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitConfigReheatEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.10
Enable/disable reheat.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitConfigHeatAssistEnable 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.11
Enable/disable heat assist.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP100UnitConfigPowerSourceConfig 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.12
Configure the input power source: (1) single feed or (2) dual feed.
OBJECT-TYPE    
  INTEGER single(1), dual(2)  

airIRRP100UnitConfigUnitRoleOverride 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.13
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
OBJECT-TYPE    
  INTEGER automatic(1), forcedOn(2)  

airIRRP500 1.3.6.1.4.1.318.1.1.13.3.3.2
OBJECT IDENTIFIER    

airIRRP500Group 1.3.6.1.4.1.318.1.1.13.3.3.2.1
OBJECT IDENTIFIER    

airIRRP500GroupStatus 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1
OBJECT IDENTIFIER    

airIRRP500GroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.1
Group air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.2
Group air flow in liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.3
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.4
Group maximum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.5
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.6
Group minimum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.7
Group coolant demand in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.8
Group coolant output in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusHumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.9
The amount of humidification the group is demanding from the humidifiers in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusHumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.10
The actual amount of humidification the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusDehumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.11
The amount of dehumidification the group is demanding from the electric heaters in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusDehumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.12
The actual amount of dehumidification the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusReheatDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.13
The amount of heating the group is demanding from the electric heaters in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupStatusReheatOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.14
The actual amount of heating the group is supplying in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpoints 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2
OBJECT IDENTIFIER    

airIRRP500GroupSetpointsCoolUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.1
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsCoolMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.2
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsSupplyAirUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.3
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsSupplyAirMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.4
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsHumidify 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.5
Group humidify setpoint in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsDehumidify 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.6
Group dehumidify setpoint in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsDehumidifyDeadband 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.7
Group dehumidify deadband in percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsReheatUS 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.8
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsReheatMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.9
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupSetpointsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.10
The preferred fan speed setting.
OBJECT-TYPE    
  INTEGER low(1), med-low(2), med(3), med-high(4), high(5)  

airIRRP500GroupSetpointsFanSpeedControl 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.11
The fan speed control setting.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRRP500GroupConfig 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3
OBJECT IDENTIFIER    

airIRRP500GroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.1
The number of cooling units.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.2
The group configuration type.
OBJECT-TYPE    
  INTEGER racs(1), hacs(2), in-row(3)  

airIRRP500GroupConfigPercentGlycol 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.3
The glycol mixture in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigCoolGainP 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.4
The gain component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigCoolResetRateI 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.5
The integral component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigCoolDerivativeD 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.6
The derivative component of the cool PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigHumidifySensitivityBand 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.7
The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigReheatGainP 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.8
The gain component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigReheatResetRateI 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.9
The integral component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigReheatDerivativeD 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.10
The derivative component of the reheat PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigMaxFanSpeed 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.11
The maximum desired fan speed setting in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigNumberofBackupUnits 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.12
The number of backup units.
OBJECT-TYPE    
  INTEGER  

airIRRP500GroupConfigRuntimeBalancingEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.13
Enable or disable runtime balancing feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRRP500GroupConfigLoadAssistEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.14
Enable or disable load assist feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRRP500GroupConfigFullRPBackups 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.15
The number of full featured RPs that can be used as backup units.
OBJECT-TYPE    
  INTEGER  

airIRRP500Unit 1.3.6.1.4.1.318.1.1.13.3.3.2.2
OBJECT IDENTIFIER    

airIRRP500UnitIdent 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1
OBJECT IDENTIFIER    

airIRRP500UnitIdentID 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.1
The unit identification number.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitIdentName 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.2
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentLocation 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.3
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentModelNumber 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.4
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentSerialNumber 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.5
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.6
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.7
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitIdentManufactureDate 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.8
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRRP500UnitStatus 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2
OBJECT IDENTIFIER    

airIRRP500UnitStatusOperateMode 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1
The cooling unit operating mode.
OBJECT-TYPE    
  INTEGER standby(1), on(2), idle(3), prestart(4), backup(5), assist(6)  

airIRRP500UnitStatusMaximumRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.2
The maximum unit rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusMaximumRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.3
The maximum unit rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusSupplyAirTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.4
The unit supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusSupplyAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5
The unit supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.6
The unit return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7
The unit return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusSupplyHumidity 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8
The relative humidity of the supply air in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusReturnHumidity 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.9
The relative humidity of the return air in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.10
The unit air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11
The unit air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusFanSpeed 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12
The unit average fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13
The unit cooling demand in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14
The unit cooling output in tenths of kiloWatts.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusHumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.15
The amount of humidification the unit is demanding from the humidifier in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusHumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.16
The actual humidification output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusDehumidifyDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.17
The amount of dehumidification the unit is demanding in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusDehumidifyOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.18
The actual dehumidification output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusReheatDemand 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.19
The amount of heating the unit is demanding from the electric heater in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusReheatOutput 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.20
The actual heating output of the unit in percent.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusInputState 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21
The state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP500UnitStatusOutputState 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22
The state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP500UnitStatusRackInletTemperature1US 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.23
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusRackInletTemperature1Metric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusRackInletTemperature2US 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.25
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusRackInletTemperature2Metric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusRackInletTemperature3US 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.27
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusRackInletTemperature3Metric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28
The unit rack inlet temperature sensor in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusContainmtDPUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.29
The unit containment differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusContainmtDPMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.30
The unit containment differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusFilterDPUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.31
The unit air filter differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusFilterDPMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.32
The unit air filter differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusHumidifierCurrent 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33
The humidifier current of the unit in amperes.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusHumidifierWaterConductivity 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.34
The water conductivity in the humidifier of the unit in microSiemens/cm.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusActivePowerSource 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.35
The power source that is powering the unit.
OBJECT-TYPE    
  INTEGER sourceA(1), sourceB(2)  

airIRRP500UnitStatusFluidValvePosition 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.36
The fluid valve position in percent open.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusFluidFlowUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.37
The fluid flow in tenths of gallons per minute.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusFluidFlowMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.38
The fluid flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusEnteringFluidTemperatureUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.39
The temperature of the entering fluid in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusEnteringFluidTemperatureMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.40
The temperature of the entering fluid in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusLeavingFluidTemperatureUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.41
The temperature of the Leaving fluid in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitStatusLeavingFluidTemperatureMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.42
The temperature of the Leaving fluid in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHours 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3
OBJECT IDENTIFIER    

airIRRP500UnitRunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.1
Unit air filter run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursCondensatePump 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.2
Unit condensate pump run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursHumidifier 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.3
Unit fan right power supply run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursFan1 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.4
Unit fan 1 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursHeater1 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.5
Unit heater 1 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursFan2 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.6
Unit fan 2 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursHeater2 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.7
Unit Heater 2 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursFan3 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.8
Unit fan 3 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursHeater3 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.9
Unit heater 3 run hours in hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitRunHoursSystem 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.10
Total system run hours.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervals 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4
OBJECT IDENTIFIER    

airIRRP500UnitServiceIntervalAirFilter 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.1
Air filter service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervalAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.2
The air filter service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitServiceIntervalHumidifier 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.3
Humidifier service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervalHumidifierAlarm 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.4
The humidifier service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitServiceIntervalHeater 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.5
Heater service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervalHeaterAlarm 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.6
The heater service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitServiceIntervalCondensatePump 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.7
Condensate pump service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervalCondensatePumpAlarm 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.8
The condensate pump service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitServiceIntervalFans 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.9
Fans service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitServiceIntervalFansAlarm 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.10
The fans service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitThresholds 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5
OBJECT IDENTIFIER    

airIRRP500UnitThresholdsRackInletHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.1
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsRackInletHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.2
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsSupplyAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.3
Unit supply air temperature high threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsSupplyAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.4
Unit supply air high temperature high threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsReturnAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.5
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsReturnAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.6
Unit return air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsSupplyHumidityHigh 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.7
Unit supply humidity high threshold in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsSupplyHumidityLow 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.8
Unit supply humidity low threshold in tenths of percent relative humidity.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsEnteringFluidHighTempUS 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.9
Entering fluid high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitThresholdsEnteringFluidHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.10
Entering fluid high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitConfig 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6
OBJECT IDENTIFIER    

airIRRP500UnitConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.1
The startup delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRRP500UnitConfigCoolCapacity 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.2
The cooling capacity options setting.
OBJECT-TYPE    
  INTEGER automatic(1), maximum(2)  

airIRRP500UnitConfigIdleOnLeakDetect 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.3
The idle on leak options setting.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRRP500UnitConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.4
The normal state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP500UnitConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.5
The normal state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRRP500UnitConfigOutputSource 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.6
The source of output relay change.
OBJECT-TYPE    
  INTEGER anyAlarm(1), criticalAlarm(2)  

airIRRP500UnitConfigHumidifyEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.7
Enable/disable humidification.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitConfigHumidifierControl 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.8
The humidifier drain control.
OBJECT-TYPE    
  INTEGER auto(1), drainOff(2)  

airIRRP500UnitConfigDehumidifyEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.9
Enable/disable dehumidification.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitConfigReheatEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.10
Enable/disable reheat.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitConfigHeatAssistEnable 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.11
Enable/disable heat assist.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRRP500UnitConfigPowerSourceConfig 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.12
Configure the input power source: (1) single feed or (2) dual feed.
OBJECT-TYPE    
  INTEGER single(1), dual(2)  

airIRRP500UnitConfigUnitRoleOverride 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.13
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
OBJECT-TYPE    
  INTEGER automatic(1), forcedOn(2)  

airIRSC 1.3.6.1.4.1.318.1.1.13.3.4
OBJECT IDENTIFIER    

airIRSCUnit 1.3.6.1.4.1.318.1.1.13.3.4.1
OBJECT IDENTIFIER    

airIRSCUnitIdent 1.3.6.1.4.1.318.1.1.13.3.4.1.1
OBJECT IDENTIFIER    

airIRSCUnitIdentName 1.3.6.1.4.1.318.1.1.13.3.4.1.1.1
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentLocation 1.3.6.1.4.1.318.1.1.13.3.4.1.1.2
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentModelNumber 1.3.6.1.4.1.318.1.1.13.3.4.1.1.3
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentSerialNumber 1.3.6.1.4.1.318.1.1.13.3.4.1.1.4
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.3.4.1.1.5
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.3.4.1.1.6
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitIdentManufactureDate 1.3.6.1.4.1.318.1.1.13.3.4.1.1.7
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRSCUnitStatus 1.3.6.1.4.1.318.1.1.13.3.4.1.2
OBJECT IDENTIFIER    

airIRSCUnitStatusOperateMode 1.3.6.1.4.1.318.1.1.13.3.4.1.2.1
The cooling unit operating mode.
OBJECT-TYPE    
  INTEGER standby(1), on(2), idle(3)  

airIRSCUnitStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.4.1.2.2
The unit cooling output in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.4.1.2.3
The unit cooling demand in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.4
The unit air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.5
The unit air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.6
The unit rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.7
The unit rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSupplyAirTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.8
The unit supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSupplyAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.9
The unit supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.10
The unit return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.11
The unit return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuctionTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.12
The unit suction temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuctionTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.13
The unit suction temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuperheatTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.14
The unit superheat temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuperheatTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.15
The unit superheat temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusContainmtDPUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.16
The unit containment differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusContainmtDPMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.17
The unit containment differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusFilterDPUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.18
The unit air filter differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusFilterDPMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.19
The unit air filter differential pressure in Pa.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuctionPressureUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.20
Unit suction pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusSuctionPressureMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.21
Unit suction pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusDischargePressureUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.22
Unit discharge pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusDischargePressureMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.23
Unit discharge pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusEvaporatorFanSpeed 1.3.6.1.4.1.318.1.1.13.3.4.1.2.24
The unit average evaporator fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCondenserFanSpeed 1.3.6.1.4.1.318.1.1.13.3.4.1.2.25
The unit average condenser fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusInputState 1.3.6.1.4.1.318.1.1.13.3.4.1.2.26
The state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRSCUnitStatusOutputState 1.3.6.1.4.1.318.1.1.13.3.4.1.2.27
The state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRSCUnitStatusCondOutletTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.28
The unit condenser outlet air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCondOutletTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.29
The unit condenser outlet air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCondInletTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.2.30
The unit condenser inlet air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCondInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.2.31
The unit condenser inlet air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitStatusCompressor 1.3.6.1.4.1.318.1.1.13.3.4.1.2.32
The state (off/on) of the compressor.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

airIRSCUnitRunHours 1.3.6.1.4.1.318.1.1.13.3.4.1.3
OBJECT IDENTIFIER    

airIRSCUnitRunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.3.4.1.3.1
Unit air filter run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursEvaporatorFan1 1.3.6.1.4.1.318.1.1.13.3.4.1.3.2
Unit evaporator fan 1 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursEvaporatorFan2 1.3.6.1.4.1.318.1.1.13.3.4.1.3.3
Unit evaporator fan 2 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursEvaporatorFan3 1.3.6.1.4.1.318.1.1.13.3.4.1.3.4
Unit evaporator fan 3 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursCondenserFan1 1.3.6.1.4.1.318.1.1.13.3.4.1.3.5
Unit condenser fan 1 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursCondenserFan2 1.3.6.1.4.1.318.1.1.13.3.4.1.3.6
Unit condenser fan 2 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursCondenserFan3 1.3.6.1.4.1.318.1.1.13.3.4.1.3.7
Unit condenser fan 3 run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursFanPowerSupplyLeft 1.3.6.1.4.1.318.1.1.13.3.4.1.3.8
Unit fan left power supply run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursFanPowerSupplyRight 1.3.6.1.4.1.318.1.1.13.3.4.1.3.9
Unit fan right power supply run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursCondensatePump 1.3.6.1.4.1.318.1.1.13.3.4.1.3.10
Unit condensate pump run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitRunHoursCompressor 1.3.6.1.4.1.318.1.1.13.3.4.1.3.11
Unit compressor run hours.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitServiceIntervals 1.3.6.1.4.1.318.1.1.13.3.4.1.4
OBJECT IDENTIFIER    

airIRSCUnitServiceIntervalsAirFilter 1.3.6.1.4.1.318.1.1.13.3.4.1.4.1
Air filter service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitServiceIntervalsAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.3.4.1.4.2
The air filter service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRSCUnitThresholds 1.3.6.1.4.1.318.1.1.13.3.4.1.5
OBJECT IDENTIFIER    

airIRSCUnitThresholdsRackInletHighTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.5.1
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitThresholdsRackInletHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.5.2
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitThresholdsSupplyAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.5.3
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitThresholdsSupplyAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.5.4
Unit supply air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitThresholdsReturnAirHighTempUS 1.3.6.1.4.1.318.1.1.13.3.4.1.5.5
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitThresholdsReturnAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.5.6
Unit return air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetpoints 1.3.6.1.4.1.318.1.1.13.3.4.1.6
OBJECT IDENTIFIER    

airIRSCUnitSetptsCoolSetpointUS 1.3.6.1.4.1.318.1.1.13.3.4.1.6.1
Unit cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetptsCoolSetpointMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.6.2
Unit cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetptsCoolDeadbandUS 1.3.6.1.4.1.318.1.1.13.3.4.1.6.3
Unit cooling deadband in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetptsCoolDeadbandMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.6.4
Unit cooling deadband in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetptsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.3.4.1.6.5
The preferred fan speed setting.
OBJECT-TYPE    
  AirIRSCFanSpeedPreference  

airIRSCUnitSetptsSupplyAirSetpointUS 1.3.6.1.4.1.318.1.1.13.3.4.1.6.6
Unit supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitSetptsSupplyAirSetpointMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.6.7
Unit supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitConfig 1.3.6.1.4.1.318.1.1.13.3.4.1.7
OBJECT IDENTIFIER    

airIRSCUnitConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.3.4.1.7.1
The unit configuration type.
OBJECT-TYPE    
  AirIRSCConfigType  

airIRSCUnitConfigCapacityControlType 1.3.6.1.4.1.318.1.1.13.3.4.1.7.2
The unit capacity control.
OBJECT-TYPE    
  AirIRSCCapacityControlType  

airIRSCUnitConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.3.4.1.7.3
The startup delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitConfigIdleOnLeakDetect 1.3.6.1.4.1.318.1.1.13.3.4.1.7.4
The idle on leak options setting.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRSCUnitConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.3.4.1.7.5
The normal state of the input contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRSCUnitConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.3.4.1.7.6
The normal state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRSCUnitConfigOutputSource 1.3.6.1.4.1.318.1.1.13.3.4.1.7.7
The source of output relay change.
OBJECT-TYPE    
  INTEGER anyAlarm(1), criticalAlarm(2)  

airIRSCUnitConfigAltitudeUS 1.3.6.1.4.1.318.1.1.13.3.4.1.7.8
The altitude of the unit above sea level in feet.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitConfigAltitudeMetric 1.3.6.1.4.1.318.1.1.13.3.4.1.7.9
The altitude of the unit above sea level in meters.
OBJECT-TYPE    
  INTEGER  

airIRSCUnitConfigOpControl 1.3.6.1.4.1.318.1.1.13.3.4.1.7.10
The unit operational control.
OBJECT-TYPE    
  INTEGER standby(1), on(2)  

airIRSCGroup 1.3.6.1.4.1.318.1.1.13.3.4.2
OBJECT IDENTIFIER    

airIRSCGroupStatus 1.3.6.1.4.1.318.1.1.13.3.4.2.1
OBJECT IDENTIFIER    

airIRSCGroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.3.4.2.1.1
The group cooling output in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.3.4.2.1.2
The group cooling demand in tenths of kW.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.3.4.2.1.3
The group air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.1.4
The group air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.4.2.1.5
The group maximum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.1.6
The group maximum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.3.4.2.1.7
The group minimum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.1.8
The group minimum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMaxReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.4.2.1.9
The group maximum return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMaxReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.1.10
The group maximum return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMinReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.3.4.2.1.11
The group minimum return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupStatusMinReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.1.12
The group minimum return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetpoints 1.3.6.1.4.1.318.1.1.13.3.4.2.2
OBJECT IDENTIFIER    

airIRSCGroupSetptsCoolSetpointUS 1.3.6.1.4.1.318.1.1.13.3.4.2.2.1
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetptsCoolSetpointMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.2.2
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetptsCoolDeadbandUS 1.3.6.1.4.1.318.1.1.13.3.4.2.2.3
Group cooling deadband in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetptsCoolDeadbandMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.2.4
Group cooling deadband in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetptsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.3.4.2.2.5
The group preferred fan speed setting.
OBJECT-TYPE    
  AirIRSCFanSpeedPreference  

airIRSCGroupSetptsSupplyAirSetpointUS 1.3.6.1.4.1.318.1.1.13.3.4.2.2.6
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupSetptsSupplyAirSetpointMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.2.7
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupConfig 1.3.6.1.4.1.318.1.1.13.3.4.2.3
OBJECT IDENTIFIER    

airIRSCGroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.3.4.2.3.1
The number of cooling units.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.3.4.2.3.2
The group configuration type.
OBJECT-TYPE    
  AirIRSCConfigType  

airIRSCGroupConfigCapacityControlType 1.3.6.1.4.1.318.1.1.13.3.4.2.3.3
The group capacity control.
OBJECT-TYPE    
  AirIRSCCapacityControlType  

airIRSCGroupConfigAltitudeUS 1.3.6.1.4.1.318.1.1.13.3.4.2.3.4
The group altitude of the units above sea level in feet.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupConfigAltitudeMetric 1.3.6.1.4.1.318.1.1.13.3.4.2.3.5
The group altitude of the units above sea level in meters.
OBJECT-TYPE    
  INTEGER  

airIRSCGroupConfigFanSpeedControl 1.3.6.1.4.1.318.1.1.13.3.4.2.3.6
The group fan speed control.
OBJECT-TYPE    
  AirIRSCFanSpeedControl  

airIRGen2 1.3.6.1.4.1.318.1.1.13.4
OBJECT IDENTIFIER    

airIRG2Ident 1.3.6.1.4.1.318.1.1.13.4.1
OBJECT IDENTIFIER    

airIRG2IdentName 1.3.6.1.4.1.318.1.1.13.4.1.1
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentLocation 1.3.6.1.4.1.318.1.1.13.4.1.2
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentModelNumber 1.3.6.1.4.1.318.1.1.13.4.1.3
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentSerialNumber 1.3.6.1.4.1.318.1.1.13.4.1.4
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.4.1.5
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.4.1.6
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentManufactureDate 1.3.6.1.4.1.318.1.1.13.4.1.7
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRG2IdentUnitSysOID 1.3.6.1.4.1.318.1.1.13.4.1.8
This OID contains an OID path to the device's top level unit data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRG2IdentGroupSysOID 1.3.6.1.4.1.318.1.1.13.4.1.9
This OID contains an OID path to the device's top level group data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRG2Group 1.3.6.1.4.1.318.1.1.13.4.2
OBJECT IDENTIFIER    

airIRG2GroupStatus 1.3.6.1.4.1.318.1.1.13.4.2.1
OBJECT IDENTIFIER    

airIRG2GroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.4.2.1.1
The group cooling output in tenths of kilowatts (kW).
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.4.2.1.2
The group cooling demand in tenths of kilowatts (kW).
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.4.2.1.3
The group air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.4.2.1.4
The group air flow in hundredths of liters per second.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.4.2.1.5
The group maximum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.4.2.1.6
The group maximum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.4.2.1.7
The group minimum rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.4.2.1.8
The group minimum rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMaxReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.4.2.1.9
The group maximum return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMaxReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.4.2.1.10
The group maximum return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMinReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.4.2.1.11
The group minimum return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupStatusMinReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.4.2.1.12
The group minimum return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetpoints 1.3.6.1.4.1.318.1.1.13.4.2.2
OBJECT IDENTIFIER    

airIRG2GroupSetptsCoolSetpointUS 1.3.6.1.4.1.318.1.1.13.4.2.2.1
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetptsCoolSetpointMetric 1.3.6.1.4.1.318.1.1.13.4.2.2.2
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetptsCoolDeadbandUS 1.3.6.1.4.1.318.1.1.13.4.2.2.3
Group cooling deadband in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetptsCoolDeadbandMetric 1.3.6.1.4.1.318.1.1.13.4.2.2.4
Group cooling deadband in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetptsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.4.2.2.5
The group preferred fan speed setting.
OBJECT-TYPE    
  INTEGER low(1), med-low(2), med(3), med-high(4), high(5)  

airIRG2GroupSetptsSupplyAirSetpointUS 1.3.6.1.4.1.318.1.1.13.4.2.2.6
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupSetptsSupplyAirSetpointMetric 1.3.6.1.4.1.318.1.1.13.4.2.2.7
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfig 1.3.6.1.4.1.318.1.1.13.4.2.3
OBJECT IDENTIFIER    

airIRG2GroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.4.2.3.1
The number of cooling units.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.4.2.3.2
The group configuration type.
OBJECT-TYPE    
  INTEGER racs(1), spot(2), in-row(3), hacs(4)  

airIRG2GroupConfigCapacityControlType 1.3.6.1.4.1.318.1.1.13.4.2.3.3
The group capacity control.
OBJECT-TYPE    
  INTEGER discrete(1), proportional(2)  

airIRG2GroupConfigFanSpeedControl 1.3.6.1.4.1.318.1.1.13.4.2.3.4
The group fan speed control.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRG2GroupConfigCoolGainP 1.3.6.1.4.1.318.1.1.13.4.2.3.5
The gain component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfigCoolResetRateI 1.3.6.1.4.1.318.1.1.13.4.2.3.6
The integral component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfigCoolDerivativeD 1.3.6.1.4.1.318.1.1.13.4.2.3.7
The derivative component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfigCoolPIDReset 1.3.6.1.4.1.318.1.1.13.4.2.3.8
Will reset the PID coefficients back to the factory defaults.
OBJECT-TYPE    
  INTEGER readBack(1), reset(2)  

airIRG2GroupConfigNumberofBackupUnits 1.3.6.1.4.1.318.1.1.13.4.2.3.9
The number of backup units.
OBJECT-TYPE    
  INTEGER  

airIRG2GroupConfigRuntimeBalancingEnable 1.3.6.1.4.1.318.1.1.13.4.2.3.10
Enable or disable runtime balancing feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRG2GroupConfigLoadAssistEnable 1.3.6.1.4.1.318.1.1.13.4.2.3.11
Enable or disable load assist feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRG2Alarms 1.3.6.1.4.1.318.1.1.13.4.3
OBJECT IDENTIFIER    

airIRG2AlarmsTableSize 1.3.6.1.4.1.318.1.1.13.4.3.1
The number of active alarms in the airIRG2AlarmsTable.
OBJECT-TYPE    
  INTEGER  

airIRG2AlarmsTable 1.3.6.1.4.1.318.1.1.13.4.3.2
Table of active alarms for the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG2AlarmsEntry

airIRG2AlarmsEntry 1.3.6.1.4.1.318.1.1.13.4.3.2.1
Alarms specification
OBJECT-TYPE    
  AirIRG2AlarmsEntry  

airIRG2AlarmsIndex 1.3.6.1.4.1.318.1.1.13.4.3.2.1.1
Alarm index.
OBJECT-TYPE    
  INTEGER  

airIRG2AlarmsEventCode 1.3.6.1.4.1.318.1.1.13.4.3.2.1.2
Code for the alarm.
OBJECT-TYPE    
  INTEGER  

airIRG2AlarmsDescription 1.3.6.1.4.1.318.1.1.13.4.3.2.1.3
Description of the alarm.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

airIRG2RC 1.3.6.1.4.1.318.1.1.13.4.4
OBJECT IDENTIFIER    

airIRG2RD 1.3.6.1.4.1.318.1.1.13.4.5
OBJECT IDENTIFIER    

airIRG2RDType1 1.3.6.1.4.1.318.1.1.13.4.5.1
OBJECT IDENTIFIER    

airIRG2RDType2 1.3.6.1.4.1.318.1.1.13.4.5.2
OBJECT IDENTIFIER    

airIRG2RDT2Status 1.3.6.1.4.1.318.1.1.13.4.5.2.1
OBJECT IDENTIFIER    

airIRG2RDT2StatusOperateMode 1.3.6.1.4.1.318.1.1.13.4.5.2.1.1
The cooling unit operating mode.
OBJECT-TYPE    
  INTEGER standby(1), on(2), idle(3), reserved(4), service(5)  

airIRG2RDT2StatusCoolOutput 1.3.6.1.4.1.318.1.1.13.4.5.2.1.2
The unit cooling output in tenths of kilowatts (kW).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusCoolDemand 1.3.6.1.4.1.318.1.1.13.4.5.2.1.3
The unit cooling demand in tenths of kilowatts (kW).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.4
The unit air flow in cubic feet per minute.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.5
The unit air flow in liters per second.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusRackInletTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.6
The unit rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.7
The unit rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSupplyAirTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.8
The unit supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSupplyAirTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.9
The unit supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.10
The unit return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.11
The unit return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuctionTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.12
The unit suction temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuctionTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.13
The unit suction temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuperheatTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.14
The unit superheat temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuperheatTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.15
The unit superheat temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusFilterDPUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.16
The unit air filter differential pressure in hundredths of inches of water.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusFilterDPMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.17
The unit air filter differential pressure in pascals (Pa).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuctionPressureUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.18
Unit suction pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusSuctionPressureMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.19
Unit suction pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusDischargePressureUS 1.3.6.1.4.1.318.1.1.13.4.5.2.1.20
Unit discharge pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusDischargePressureMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.1.21
Unit discharge pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusEvaporatorFanSpeed 1.3.6.1.4.1.318.1.1.13.4.5.2.1.22
The unit average evaporator fan speed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusInputState 1.3.6.1.4.1.318.1.1.13.4.5.2.1.23
The state of the input contact.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2StatusOutputState 1.3.6.1.4.1.318.1.1.13.4.5.2.1.24
The state of the output relay.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2StatusOHEInputState 1.3.6.1.4.1.318.1.1.13.4.5.2.1.25
The state of the outside heat exchanger(OHE) input contact.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2StatusOHEOutputState 1.3.6.1.4.1.318.1.1.13.4.5.2.1.26
The state of the outside heat exchanger(OHE) output relay.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2StatusCompressor 1.3.6.1.4.1.318.1.1.13.4.5.2.1.27
The state (off/on) of the compressor.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

airIRG2RDT2StatusFluidValvePos 1.3.6.1.4.1.318.1.1.13.4.5.2.1.28
The position of the fluid valve in percent. This OID is only valid when airIRG2RDT2ConfigUnitType indicates fluidCooled(1).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2StatusHotGasBypassValvePos 1.3.6.1.4.1.318.1.1.13.4.5.2.1.29
The position of the hot gas bypass valve in hundredths of percent.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHours 1.3.6.1.4.1.318.1.1.13.4.5.2.2
OBJECT IDENTIFIER    

airIRG2RDT2RunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.4.5.2.2.1
Unit air filter run hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursCondensatePump 1.3.6.1.4.1.318.1.1.13.4.5.2.2.2
Unit condensate pump run hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursCompressor 1.3.6.1.4.1.318.1.1.13.4.5.2.2.3
Unit compressor run hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursFanPSTableSize 1.3.6.1.4.1.318.1.1.13.4.5.2.2.4
The number of entries in the run hour fan power supply table (airIRG2RDT2RunHoursFanPSTable).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursFanPSTable 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5
Allows for getting run hour information from each power supply.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG2RDT2RunHoursFanPSEntry

airIRG2RDT2RunHoursFanPSEntry 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1
The run hours fan power supply table entry.
OBJECT-TYPE    
  AirIRG2RDT2RunHoursFanPSEntry  

airIRG2RDT2RunHoursFanPSIndex 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.1
Index of run hours fan power supply table.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursFanPSHours 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.2
Fan power supply run time in hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursFanPSPosition 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.3
Position of fan power supply within the unit.
OBJECT-TYPE    
  INTEGER upper(1), lower(2), left(3), right(4)  

airIRG2RDT2RunHoursEvapFanTableSize 1.3.6.1.4.1.318.1.1.13.4.5.2.2.6
The number of entries in the run hour evaporator fan table (airIRG2RDT2RunHoursEvapFanTable).
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursEvapFanTable 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7
Allows for getting information from each evaporator fan run hour in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG2RDT2RunHoursEvapFanEntry

airIRG2RDT2RunHoursEvapFanEntry 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1
Allows for getting information from each evaporator fan run hour in the system.
OBJECT-TYPE    
  AirIRG2RDT2RunHoursEvapFanEntry  

airIRG2RDT2RunHoursEvapFanIndex 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.1
Index of run hours evaporator fan table.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursEvapFanHours 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.2
Evaporator fan run time in hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2RunHoursUnit 1.3.6.1.4.1.318.1.1.13.4.5.2.2.8
Unit run time in hours.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ServiceIntervals 1.3.6.1.4.1.318.1.1.13.4.5.2.3
OBJECT IDENTIFIER    

airIRG2RDT2ServiceIntervalsAirFilter 1.3.6.1.4.1.318.1.1.13.4.5.2.3.1
Air filter service interval in weeks.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ServiceIntervalsAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.4.5.2.3.2
The air filter service interval alarm enable/disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRG2RDT2Thresholds 1.3.6.1.4.1.318.1.1.13.4.5.2.4
OBJECT IDENTIFIER    

airIRG2RDT2ThresholdsRackInletHighTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.4.1
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ThresholdsRackInletHighTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.4.2
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ThresholdsSupplyAirHighTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.4.3
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ThresholdsSupplyAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.4.4
Unit supply air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ThresholdsReturnAirHighTempUS 1.3.6.1.4.1.318.1.1.13.4.5.2.4.5
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ThresholdsReturnAirHighTempMetric 1.3.6.1.4.1.318.1.1.13.4.5.2.4.6
Unit return air high temperature threshold in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2Setpoints 1.3.6.1.4.1.318.1.1.13.4.5.2.5
OBJECT IDENTIFIER    

airIRG2RDT2Config 1.3.6.1.4.1.318.1.1.13.4.5.2.6
OBJECT IDENTIFIER    

airIRG2RDT2ConfigUnitType 1.3.6.1.4.1.318.1.1.13.4.5.2.6.1
The type of the unit.
OBJECT-TYPE    
  INTEGER fluidCooled(1), airCooled(2)  

airIRG2RDT2ConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.4.5.2.6.2
The startup delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRG2RDT2ConfigIdleOnLeakDetect 1.3.6.1.4.1.318.1.1.13.4.5.2.6.3
The idle on leak options setting.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

airIRG2RDT2ConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.4.5.2.6.4
The normal state of the input contact.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2ConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.4.5.2.6.5
The normal state of the output relay.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2ConfigOutputSource 1.3.6.1.4.1.318.1.1.13.4.5.2.6.6
The source of output relay change.
OBJECT-TYPE    
  INTEGER anyAlarm(1), criticalAlarm(2)  

airIRG2RDT2ConfigOHEInputNormalState 1.3.6.1.4.1.318.1.1.13.4.5.2.6.7
The normal state of the outside heat exchanger(OHE) input relay.
OBJECT-TYPE    
  AirIRG2RDType2IOState  

airIRG2RDT2ConfigUnitRoleOverride 1.3.6.1.4.1.318.1.1.13.4.5.2.6.8
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
OBJECT-TYPE    
  INTEGER automatic(1), forcedOn(2)  

airIRG2RDT2ConfigUnitIdleOnCoolFail 1.3.6.1.4.1.318.1.1.13.4.5.2.6.9
When this OID value is (2) yes, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG2SC 1.3.6.1.4.1.318.1.1.13.4.6
OBJECT IDENTIFIER    

airIRG2RA 1.3.6.1.4.1.318.1.1.13.4.7
OBJECT IDENTIFIER    

airInRoom 1.3.6.1.4.1.318.1.1.13.5
OBJECT IDENTIFIER    

airIRmIdent 1.3.6.1.4.1.318.1.1.13.5.1
OBJECT IDENTIFIER    

airIRmIdentName 1.3.6.1.4.1.318.1.1.13.5.1.1
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRmIdentLocation 1.3.6.1.4.1.318.1.1.13.5.1.2
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRmIdentModelNumber 1.3.6.1.4.1.318.1.1.13.5.1.3
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRmIdentSerialNumber 1.3.6.1.4.1.318.1.1.13.5.1.4
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRmIdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.5.1.5
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRmIdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.5.1.6
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRmIdentManufactureDate 1.3.6.1.4.1.318.1.1.13.5.1.7
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRmIdentSysOID 1.3.6.1.4.1.318.1.1.13.5.1.8
This OID contains an OID path to the device's top level data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRmAlarms 1.3.6.1.4.1.318.1.1.13.5.2
OBJECT IDENTIFIER    

airIRmAlarmsTableSize 1.3.6.1.4.1.318.1.1.13.5.2.1
The number of active alarms in the airIRG2AlarmsTable.
OBJECT-TYPE    
  INTEGER  

airIRmAlarmsTable 1.3.6.1.4.1.318.1.1.13.5.2.2
Table of active alarms for the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRmAlarmsEntry

airIRmAlarmsEntry 1.3.6.1.4.1.318.1.1.13.5.2.2.1
Alarms specification
OBJECT-TYPE    
  AirIRmAlarmsEntry  

airIRmAlarmsIndex 1.3.6.1.4.1.318.1.1.13.5.2.2.1.1
Alarm index.
OBJECT-TYPE    
  INTEGER  

airIRmAlarmsEventCode 1.3.6.1.4.1.318.1.1.13.5.2.2.1.2
Code for the alarm.
OBJECT-TYPE    
  INTEGER  

airIRmAlarmsDescription 1.3.6.1.4.1.318.1.1.13.5.2.2.1.3
Description of the alarm.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

airIRmPerimeter 1.3.6.1.4.1.318.1.1.13.5.3
OBJECT IDENTIFIER    

airIRmPmCommon1 1.3.6.1.4.1.318.1.1.13.5.3.2
OBJECT IDENTIFIER    

airIRmPmUnitType 1.3.6.1.4.1.318.1.1.13.5.3.2.1
Unit type (1).
OBJECT-TYPE    
  INTEGER mc(1), dx(2), cw(3), ch(4), ecoCool(5), msc(6), ge1(7), ge2(8), dualFluid(9), cw2(10), unknown(256)  

airIRmPmSwVersion 1.3.6.1.4.1.318.1.1.13.5.3.2.3
Software version (3).
OBJECT-TYPE    
  DisplayString  

airIRmPmBusAddress 1.3.6.1.4.1.318.1.1.13.5.3.2.5
Bus addresss of unit (5).
OBJECT-TYPE    
  INTEGER 0..65535  

airIRmPmControllerType 1.3.6.1.4.1.318.1.1.13.5.3.2.7
Controller type (7).
OBJECT-TYPE    
  INTEGER unknown(1), c4000(2), c1001(3), c1002(4), c5000(5), c6000(6), c1010(7), c7000IOC(8), c7000AT(9), c7000PT(10), c5MSC(11), c7000PT2(12)  

airIRmPmGeneralError 1.3.6.1.4.1.318.1.1.13.5.3.2.8
General Error (8)
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmErrorOnBus 1.3.6.1.4.1.318.1.1.13.5.3.2.9
Error On Bus (9)
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCommon2 1.3.6.1.4.1.318.1.1.13.5.3.3
OBJECT IDENTIFIER    

airIRmPmPCStop 1.3.6.1.4.1.318.1.1.13.5.3.3.1
PC-STOP (1000)
OBJECT-TYPE    
  AirIRmStopState  

airIRmPmRemoteStop 1.3.6.1.4.1.318.1.1.13.5.3.3.2
Remote Stop (1001)
OBJECT-TYPE    
  AirIRmStopState  

airIRmPmLocalStop 1.3.6.1.4.1.318.1.1.13.5.3.3.3
Local Stop (1002)
OBJECT-TYPE    
  AirIRmStopState  

airIRmPmTimerStop 1.3.6.1.4.1.318.1.1.13.5.3.3.4
Timer Stop (1003)
OBJECT-TYPE    
  AirIRmStopState  

airIRmPmSeqStop 1.3.6.1.4.1.318.1.1.13.5.3.3.5
Seq. Stop (1004)
OBJECT-TYPE    
  AirIRmStopState  

airIRmPmRemoteUPS 1.3.6.1.4.1.318.1.1.13.5.3.3.7
Remote UPS (1006)
OBJECT-TYPE    
  INTEGER off(1), on(2)  

airIRmPmLocalUPS 1.3.6.1.4.1.318.1.1.13.5.3.3.8
Local UPS (1007)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmCommonAlarm 1.3.6.1.4.1.318.1.1.13.5.3.3.11
Common alarm (1010).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmResetAllAlarms 1.3.6.1.4.1.318.1.1.13.5.3.3.12
Reset all alarms control (1011).
OBJECT-TYPE    
  INTEGER doNothing(1), reset(2)  

airIRmPmUnitOnOff 1.3.6.1.4.1.318.1.1.13.5.3.3.14
Unit running state (1013).
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmMaintenance 1.3.6.1.4.1.318.1.1.13.5.3.3.15
Maintenance necessary state (1014).
OBJECT-TYPE    
  INTEGER notNecessary(1), necessary(2)  

airIRmPmUnitTemperatureScale 1.3.6.1.4.1.318.1.1.13.5.3.3.23
Current Unit Temperature Scale (1022).
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

airIRmPmUnitWinterMode 1.3.6.1.4.1.318.1.1.13.5.3.3.24
Winter or summer configuration mode (1023).
OBJECT-TYPE    
  INTEGER summer(1), winter(2)  

airIRmPmDayNightMode 1.3.6.1.4.1.318.1.1.13.5.3.3.25
Day or night configuration mode (1024).
OBJECT-TYPE    
  INTEGER day(1), night(2)  

airIRmPmCommon3 1.3.6.1.4.1.318.1.1.13.5.3.4
OBJECT IDENTIFIER    

airIRmPmLastMaintenanceYear 1.3.6.1.4.1.318.1.1.13.5.3.4.1
Last maintenance year (1160).
OBJECT-TYPE    
  INTEGER  

airIRmPmLastMaintenanceMonth 1.3.6.1.4.1.318.1.1.13.5.3.4.2
Last maintenance month (1161).
OBJECT-TYPE    
  INTEGER 1..12  

airIRmPmLastMaintenanceDay 1.3.6.1.4.1.318.1.1.13.5.3.4.3
Last maintenance day (1162).
OBJECT-TYPE    
  INTEGER 1..31  

airIRmPmUnitMaintenanceInterval 1.3.6.1.4.1.318.1.1.13.5.3.4.4
Unit maintenance interval in months (1163).
OBJECT-TYPE    
  INTEGER 1..255  

airIRmPmRuntimeUnit 1.3.6.1.4.1.318.1.1.13.5.3.4.5
Runtime unit in hours (1164).
OBJECT-TYPE    
  INTEGER  

airIRmPmStoptimeUnit 1.3.6.1.4.1.318.1.1.13.5.3.4.6
Unit stoptime in hours (1165)
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeCooling 1.3.6.1.4.1.318.1.1.13.5.3.4.7
Cooling runtime in hours (1166)
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeHeating 1.3.6.1.4.1.318.1.1.13.5.3.4.8
Heating runtime in hours (1167)
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeHumidification 1.3.6.1.4.1.318.1.1.13.5.3.4.9
Humidification runtime in hours (1168)
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeDehumidification 1.3.6.1.4.1.318.1.1.13.5.3.4.10
Dehumidification runtime in hours (1169)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitTemperature 1.3.6.1.4.1.318.1.1.13.5.3.4.11
OBJECT IDENTIFIER    

airIRmPmUnitTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.4.11.1
Unit temperature in tenths of degrees Celsius (1170).
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.4.11.2
Unit temperature in tenths of degrees Fahrenheit (1170).
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitHumidity 1.3.6.1.4.1.318.1.1.13.5.3.4.12
Unit humidity in tenths of %RH (1171).
OBJECT-TYPE    
  INTEGER  

airIRmPmSetpointTemperatureDay 1.3.6.1.4.1.318.1.1.13.5.3.4.14
OBJECT IDENTIFIER    

airIRmPmSetpointTemperatureDayC 1.3.6.1.4.1.318.1.1.13.5.3.4.14.1
Setpoint daytime temperature in tenths of degrees Celsius (1173).
OBJECT-TYPE    
  INTEGER  

airIRmPmSetpointTemperatureDayF 1.3.6.1.4.1.318.1.1.13.5.3.4.14.2
Setpoint daytime temperature in tenths of degrees Fahrenheit (1173).
OBJECT-TYPE    
  INTEGER  

airIRmPmSetpointTemperatureNight 1.3.6.1.4.1.318.1.1.13.5.3.4.15
OBJECT IDENTIFIER    

airIRmPmSetpointTemperatureNightC 1.3.6.1.4.1.318.1.1.13.5.3.4.15.1
Setpoint nighttime temperature in tenths of degrees Celsius (1174).
OBJECT-TYPE    
  INTEGER  

airIRmPmSetpointTemperatureNightF 1.3.6.1.4.1.318.1.1.13.5.3.4.15.2
Setpoint nighttime temperature in tenths of degrees Fahrenheit (1174).
OBJECT-TYPE    
  INTEGER  

airIRmPmSetpointHumidity 1.3.6.1.4.1.318.1.1.13.5.3.4.17
Setpoint humidity in tenths of %RH (1176).
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitControlType 1.3.6.1.4.1.318.1.1.13.5.3.4.24
Current unit control type (1183).
OBJECT-TYPE    
  INTEGER room(1), supply(2), room-SupplyLimit(3), supply-RoomLimit(4)  

airIRmPmWinterModeStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.4.29
OBJECT IDENTIFIER    

airIRmPmWinterModeStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.4.29.1
Winter mode start temperature in tenths of degrees Celsius (1188).
OBJECT-TYPE    
  INTEGER  

airIRmPmWinterModeStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.4.29.2
Winter mode start temperature in tenths of degrees Fahrenheit (1188).
OBJECT-TYPE    
  INTEGER  

airIRmPmWinterModeHysteresis 1.3.6.1.4.1.318.1.1.13.5.3.4.30
OBJECT IDENTIFIER    

airIRmPmWinterModeHysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.4.30.1
Winter mode hysteresis in tenths of Kelvins (1189)
OBJECT-TYPE    
  INTEGER  

airIRmPmWinterModeHysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.4.30.2
Winter mode hysteresis in tenths of degrees Fahrenheit (1189)
OBJECT-TYPE    
  INTEGER  

airIRmPmWaterTemperature 1.3.6.1.4.1.318.1.1.13.5.3.4.32
OBJECT IDENTIFIER    

airIRmPmWaterTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.4.32.1
Water temperature in tenths of degrees Celsius (1191).
OBJECT-TYPE    
  INTEGER  

airIRmPmWaterTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.4.32.2
Water temperature in tenths of degrees Fahrenheit (1191).
OBJECT-TYPE    
  INTEGER  

airIRmPmReturnAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.4.33
OBJECT IDENTIFIER    

airIRmPmReturnAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.4.33.1
Return air temperature in tenths of degrees Celsius (1192).
OBJECT-TYPE    
  INTEGER  

airIRmPmReturnAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.4.33.2
Return air temperature in tenths of degrees Fahrenheit (1192).
OBJECT-TYPE    
  INTEGER  

airIRmPmSupplyAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.4.34
OBJECT IDENTIFIER    

airIRmPmSupplyAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.4.34.1
Supply air temperature in tenths of degrees Celsius (1193).
OBJECT-TYPE    
  INTEGER  

airIRmPmSupplyAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.4.34.2
Supply air temperature in tenths of degrees Fahrenheit (1193).
OBJECT-TYPE    
  INTEGER  

airIRmPmReturnAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.4.35
Return air humidity in tenths of %RH (1194).
OBJECT-TYPE    
  INTEGER  

airIRmPmSupplyAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.4.36
Supply air humidity in tenths of %RH (1195).
OBJECT-TYPE    
  INTEGER  

airIRmPmOutsideAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.4.37
OBJECT IDENTIFIER    

airIRmPmOutsideAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.4.37.1
Outside air temperature in tenths of degrees Celsius (1196)
OBJECT-TYPE    
  INTEGER  

airIRmPmOutsideAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.4.37.2
Outside air temperature in tenths of degrees Fahrenheit (1196)
OBJECT-TYPE    
  INTEGER  

airIRmPmOutsideAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.4.38
Outside air humidity in tenths of percent relative humidity (1197)
OBJECT-TYPE    
  INTEGER  

airIRmPmCoolingPriority 1.3.6.1.4.1.318.1.1.13.5.3.4.39
Cooling priority (1198).
OBJECT-TYPE    
  INTEGER ge(1), cw(2), dx(3)  

airIRmPmWaterTemperature2 1.3.6.1.4.1.318.1.1.13.5.3.4.43
OBJECT IDENTIFIER    

airIRmPmWaterTemperature2C 1.3.6.1.4.1.318.1.1.13.5.3.4.43.1
Water temperature 2 in tenths of degrees Celsius (1202).
OBJECT-TYPE    
  INTEGER  

airIRmPmWaterTemperature2F 1.3.6.1.4.1.318.1.1.13.5.3.4.43.2
Water temperature 2 in tenths of degrees Fahrenheit (1202).
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeFreeCooling 1.3.6.1.4.1.318.1.1.13.5.3.4.44
Freecooling runtime in hours (1203)
OBJECT-TYPE    
  INTEGER  

airIRmPmRuntimeMixedModeFreeCooling 1.3.6.1.4.1.318.1.1.13.5.3.4.45
Mixed mode freecooling runtime in hours (1203)
OBJECT-TYPE    
  INTEGER  

airIRmPmCommon4 1.3.6.1.4.1.318.1.1.13.5.3.5
OBJECT IDENTIFIER    

airIRmPmNumberOfCompressors 1.3.6.1.4.1.318.1.1.13.5.3.5.4
Number of compressors (1761)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfSuctionValves 1.3.6.1.4.1.318.1.1.13.5.3.5.5
Number of suction valves (1762)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfDryCoolers 1.3.6.1.4.1.318.1.1.13.5.3.5.6
Number of drycoolers (1763)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfPumps 1.3.6.1.4.1.318.1.1.13.5.3.5.7
Number of pumps (1764)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfElectricHeaters 1.3.6.1.4.1.318.1.1.13.5.3.5.8
Number of electric heaters (1765)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfHumidifiers 1.3.6.1.4.1.318.1.1.13.5.3.5.9
Number of humidifiers (1766)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfFans 1.3.6.1.4.1.318.1.1.13.5.3.5.10
Number of fans (1767)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfLouvers 1.3.6.1.4.1.318.1.1.13.5.3.5.11
Number of louvers (1768)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfSensors 1.3.6.1.4.1.318.1.1.13.5.3.5.12
Number of sensors (1769)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfExternalAlarmInputs 1.3.6.1.4.1.318.1.1.13.5.3.5.13
Number of external alarm inputs (1770)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfGECWValves 1.3.6.1.4.1.318.1.1.13.5.3.5.14
Number of GE/CW valves (1771)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfHotGasReheat 1.3.6.1.4.1.318.1.1.13.5.3.5.15
Number of hot gas reheaters (1772)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfPWWReheat 1.3.6.1.4.1.318.1.1.13.5.3.5.16
Number of PWW reheaters (1773)
OBJECT-TYPE    
  INTEGER  

airIRmPmNumberOfDehumidifiers 1.3.6.1.4.1.318.1.1.13.5.3.5.17
Number of dehumidifiers (1774)
OBJECT-TYPE    
  INTEGER  

airIRmPmCommon5 1.3.6.1.4.1.318.1.1.13.5.3.6
OBJECT IDENTIFIER    

airIRmPmUnitEvaporationTemperature1 1.3.6.1.4.1.318.1.1.13.5.3.6.1
OBJECT IDENTIFIER    

airIRmPmUnitEvaporationTemperature1C 1.3.6.1.4.1.318.1.1.13.5.3.6.1.1
Unit evaporation temperature 1 in tenths of degrees Celsius (2232)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitEvaporationTemperature1F 1.3.6.1.4.1.318.1.1.13.5.3.6.1.2
Unit evaporation temperature 1 in tenths of degrees Fahrenheit (2232)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitEvaporationPressure1 1.3.6.1.4.1.318.1.1.13.5.3.6.2
Unit evaporation pressure 1 in tenths of Bars (2233)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationTemperature1 1.3.6.1.4.1.318.1.1.13.5.3.6.3
OBJECT IDENTIFIER    

airIRmPmUnitCondensationTemperature1C 1.3.6.1.4.1.318.1.1.13.5.3.6.3.1
Unit condensation temperature 1 in tenths of degrees Celsius (2234)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationTemperature1F 1.3.6.1.4.1.318.1.1.13.5.3.6.3.2
Unit condensation temperature 1 in tenths of degrees Fahrenheit (2234)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationPressure1 1.3.6.1.4.1.318.1.1.13.5.3.6.4
Unit condensation pressure 1 in tenths of Bars (2235)
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitReturnAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.8
OBJECT IDENTIFIER    

airIRmPmMaxLimitReturnAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.8.1
Maximum limit return air temperature in tenths of degrees Celsius (2239).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitReturnAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.8.2
Maximum limit return air temperature in tenths of degrees Fahrenheit (2239).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitReturnAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.9
OBJECT IDENTIFIER    

airIRmPmMinLimitReturnAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.9.1
Minimum limit return air temperature in tenths of degrees Celsius (2240).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitReturnAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.9.2
Minimum limit return air temperature in tenths of degrees Fahrenheit (2240).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitSupplyAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.10
OBJECT IDENTIFIER    

airIRmPmMaxLimitSupplyAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.10.1
Maximum limit supply air temperature in tenths of degrees Celsius (2241).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitSupplyAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.10.2
Maximum limit supply air temperature in tenths of degrees Fahrenheit (2241).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitSupplyAirTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.11
OBJECT IDENTIFIER    

airIRmPmMinLimitSupplyAirTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.11.1
Minimum limit supply air temperature in tenths of degrees Celsius (2242).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitSupplyAirTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.11.2
Minimum limit supply air temperature in tenths of degrees Fahrenheit (2242).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitWaterTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.12
OBJECT IDENTIFIER    

airIRmPmMaxLimitWaterTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.12.1
Maximum limit water temperature in tenths of degrees Celsius (2243).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitWaterTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.12.2
Maximum limit water temperature in tenths of degrees Fahrenheit (2243).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitWaterTemperature 1.3.6.1.4.1.318.1.1.13.5.3.6.13
OBJECT IDENTIFIER    

airIRmPmMinLimitWaterTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.6.13.1
Minimum limit water temperature in tenths of degrees Celsius (2244).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitWaterTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.6.13.2
Minimum limit water temperature in tenths of degrees Fahrenheit (2244).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitReturnAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.6.14
Maximum limit return air humidity in tenths of %RH (2245).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitReturnAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.6.15
Minimum limit return air humidity in tenths of %RH (2246).
OBJECT-TYPE    
  INTEGER  

airIRmPmMaxLimitSupplyAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.6.16
Maximum limit supply air humidity in tenths of %RH (2247).
OBJECT-TYPE    
  INTEGER  

airIRmPmMinLimitSupplyAirHumidity 1.3.6.1.4.1.318.1.1.13.5.3.6.17
Minimum limit supply air humidity in tenths of %RH (2248).
OBJECT-TYPE    
  INTEGER  

airIRmPmLowPressureWinterDelay 1.3.6.1.4.1.318.1.1.13.5.3.6.18
Winter mode low pressure delay in seconds (2249)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationPressure2 1.3.6.1.4.1.318.1.1.13.5.3.6.19
Unit condensation pressure 2 in tenths of Bars (2250)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitOverloadSwitch 1.3.6.1.4.1.318.1.1.13.5.3.6.20
Unit overload switch setting in tenths of Kelvins (2251)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationTemperature2 1.3.6.1.4.1.318.1.1.13.5.3.6.41
OBJECT IDENTIFIER    

airIRmPmUnitCondensationTemperature2C 1.3.6.1.4.1.318.1.1.13.5.3.6.41.1
Unit condensation temperature 2 in tenths of degrees Celsius (2272)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitCondensationTemperature2F 1.3.6.1.4.1.318.1.1.13.5.3.6.41.2
Unit condensation temperature 2 in tenths of degrees Fahrenheit (2272)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitEvaporationPressure2 1.3.6.1.4.1.318.1.1.13.5.3.6.42
Unit evaporation pressure 2 in tenths of Bars (2273)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitEvaporationTemperature2 1.3.6.1.4.1.318.1.1.13.5.3.6.43
OBJECT IDENTIFIER    

airIRmPmUnitEvaporationTemperature2C 1.3.6.1.4.1.318.1.1.13.5.3.6.43.1
Unit evaporation temperature 2 in tenths of degrees Celsius (2274)
OBJECT-TYPE    
  INTEGER  

airIRmPmUnitEvaporationTemperature2F 1.3.6.1.4.1.318.1.1.13.5.3.6.43.2
Unit evaporation temperature 2 in tenths of degrees Fahrenheit (2274)
OBJECT-TYPE    
  INTEGER  

airIRmPmCompressor1 1.3.6.1.4.1.318.1.1.13.5.3.7
OBJECT IDENTIFIER    

airIRmPmCmp1ManOperationActive 1.3.6.1.4.1.318.1.1.13.5.3.7.2
Compressor 1 manual operation active (4401)
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRmPmCmp1ManOperationState 1.3.6.1.4.1.318.1.1.13.5.3.7.3
Compressor 1 manual operation state (4402)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmCmp1Running 1.3.6.1.4.1.318.1.1.13.5.3.7.4
Compressor 1 running (4403)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmCmp1StartTempSummer 1.3.6.1.4.1.318.1.1.13.5.3.7.17
OBJECT IDENTIFIER    

airIRmPmCmp1StartTempSummerK 1.3.6.1.4.1.318.1.1.13.5.3.7.17.1
Compressor 1 summer mode start temperature in tenths of Kelvins (4416)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1StartTempSummerF 1.3.6.1.4.1.318.1.1.13.5.3.7.17.2
Compressor 1 summer mode start temperature in tenths of degrees Fahrenheit (4416)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1HysteresisSummer 1.3.6.1.4.1.318.1.1.13.5.3.7.18
OBJECT IDENTIFIER    

airIRmPmCmp1HysteresisSummerK 1.3.6.1.4.1.318.1.1.13.5.3.7.18.1
Compressor 1 summer mode hysteresis setting in tenths of Kelvins (4417)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1HysteresisSummerF 1.3.6.1.4.1.318.1.1.13.5.3.7.18.2
Compressor 1 summer mode hysteresis setting in tenths of Fahrenheit (4417)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1StartTempWinter 1.3.6.1.4.1.318.1.1.13.5.3.7.19
OBJECT IDENTIFIER    

airIRmPmCmp1StartTempWinterK 1.3.6.1.4.1.318.1.1.13.5.3.7.19.1
Compressor 1 winter mode start temperature in tenths of Kelvins (4418)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1StartTempWinterF 1.3.6.1.4.1.318.1.1.13.5.3.7.19.2
Compressor 1 winter mode start temperature in tenths of degrees Fahrenheit (4418)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1HysteresisWinter 1.3.6.1.4.1.318.1.1.13.5.3.7.20
OBJECT IDENTIFIER    

airIRmPmCmp1HysteresisWinterK 1.3.6.1.4.1.318.1.1.13.5.3.7.20.1
Compressor 1 Winter mode hysteresis setting in tenths of Kelvins (4419)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1HysteresisWinterF 1.3.6.1.4.1.318.1.1.13.5.3.7.20.2
Compressor 1 Winter mode hysteresis setting in tenths of Fahrenheit (4419)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.7.29
Compressor 1 runtime in hours (4428)
OBJECT-TYPE    
  INTEGER  

airIRmPmCompressor2 1.3.6.1.4.1.318.1.1.13.5.3.8
OBJECT IDENTIFIER    

airIRmPmCmp2ManOperationActive 1.3.6.1.4.1.318.1.1.13.5.3.8.2
Compressor 2 manual operation active (4501)
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRmPmCmp2ManOperationState 1.3.6.1.4.1.318.1.1.13.5.3.8.3
Compressor 2 manual operation state (4502)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmCmp2Running 1.3.6.1.4.1.318.1.1.13.5.3.8.4
Compressor 2 running (4503)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmCmp2StartTempSummer 1.3.6.1.4.1.318.1.1.13.5.3.8.17
OBJECT IDENTIFIER    

airIRmPmCmp2StartTempSummerK 1.3.6.1.4.1.318.1.1.13.5.3.8.17.1
Compressor 2 summer mode start temperature in tenths of Kelvins (4516)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2StartTempSummerF 1.3.6.1.4.1.318.1.1.13.5.3.8.17.2
Compressor 2 summer mode start temperature in tenths of degrees Fahrenheit (4516)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2HysteresisSummer 1.3.6.1.4.1.318.1.1.13.5.3.8.18
OBJECT IDENTIFIER    

airIRmPmCmp2HysteresisSummerK 1.3.6.1.4.1.318.1.1.13.5.3.8.18.1
Compressor 2 summer mode hysteresis setting in tenths of Kelvins (4517)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2HysteresisSummerF 1.3.6.1.4.1.318.1.1.13.5.3.8.18.2
Compressor 2 summer mode hysteresis setting in tenths of Fahrenheit (4517)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2StartTempWinter 1.3.6.1.4.1.318.1.1.13.5.3.8.19
OBJECT IDENTIFIER    

airIRmPmCmp2StartTempWinterK 1.3.6.1.4.1.318.1.1.13.5.3.8.19.1
Compressor 2 winter mode start temperature in tenths of Kelvins (4518)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2StartTempWinterF 1.3.6.1.4.1.318.1.1.13.5.3.8.19.2
Compressor 2 winter mode start temperature in tenths of degrees Fahrenheit (4518)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2HysteresisWinter 1.3.6.1.4.1.318.1.1.13.5.3.8.20
OBJECT IDENTIFIER    

airIRmPmCmp2HysteresisWinterK 1.3.6.1.4.1.318.1.1.13.5.3.8.20.1
Compressor 2 Winter mode hysteresis setting in tenths of Kelvins (4519)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2HysteresisWinterF 1.3.6.1.4.1.318.1.1.13.5.3.8.20.2
Compressor 2 Winter mode hysteresis setting in tenths of Fahrenheit (4519)
OBJECT-TYPE    
  INTEGER  

airIRmPmCmp2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.8.29
Compressor 2 runtime in hours (4528)
OBJECT-TYPE    
  INTEGER  

airIRmPmSuctionValve1 1.3.6.1.4.1.318.1.1.13.5.3.9
OBJECT IDENTIFIER    

airIRmPmSuctionValve2 1.3.6.1.4.1.318.1.1.13.5.3.10
OBJECT IDENTIFIER    

airIRmPmEheating1 1.3.6.1.4.1.318.1.1.13.5.3.11
OBJECT IDENTIFIER    

airIRmPmEheating1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.11.2
Electric heater #1 manual operation enable (4801)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating1Running 1.3.6.1.4.1.318.1.1.13.5.3.11.4
Electric heater #1 running state (4803)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmEheating1ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.11.5
Electric heater #1 running in manual operation mode (4804)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating1Type 1.3.6.1.4.1.318.1.1.13.5.3.11.9
Electric heater #1 type (4808)
OBJECT-TYPE    
  INTEGER direct(1), pwm(2)  

airIRmPmEheating1StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.11.10
OBJECT IDENTIFIER    

airIRmPmEheating1StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.11.10.1
Electric heater #1 start temperature in tenths of Kelvins (4809)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating1StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.11.10.2
Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating1Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.11.11
OBJECT IDENTIFIER    

airIRmPmEheating1HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.11.11.1
Electric heater #1 hysteresis in tenths of Kelvins (4810)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating1HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.11.11.2
Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.11.17
Electric heater #1 runtime in hours (4816)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating2 1.3.6.1.4.1.318.1.1.13.5.3.12
OBJECT IDENTIFIER    

airIRmPmEheating2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.12.2
Electric heater #2 manual operation enable (4901)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating2Running 1.3.6.1.4.1.318.1.1.13.5.3.12.4
Electric heater #2 running state (4903)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmEheating2ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.12.5
Electric heater #2 running in manual operation mode (4904)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating2Type 1.3.6.1.4.1.318.1.1.13.5.3.12.9
Electric heater #2 type (4908)
OBJECT-TYPE    
  INTEGER direct(1), pwm(2)  

airIRmPmEheating2StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.12.10
OBJECT IDENTIFIER    

airIRmPmEheating2StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.12.10.1
Electric heater #2 start temperature in tenths of Kelvins (4909)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating2StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.12.10.2
Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating2Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.12.11
OBJECT IDENTIFIER    

airIRmPmEheating2HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.12.11.1
Electric heater #2 hysteresis in tenths of Kelvins (4910)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating2HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.12.11.2
Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.12.17
Electric heater #2 runtime in hours (4916)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating3 1.3.6.1.4.1.318.1.1.13.5.3.13
OBJECT IDENTIFIER    

airIRmPmEheating3ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.13.2
Electric heater #3 manual operation enable (5001)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating3Running 1.3.6.1.4.1.318.1.1.13.5.3.13.4
Electric heater #3 running state (5003)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmEheating3ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.13.5
Electric heater #3 running in manual operation mode (5004)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating3Type 1.3.6.1.4.1.318.1.1.13.5.3.13.9
Electric heater #3 type (5008)
OBJECT-TYPE    
  INTEGER direct(1), pwm(2)  

airIRmPmEheating3StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.13.10
OBJECT IDENTIFIER    

airIRmPmEheating3StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.13.10.1
Electric heater #3 start temperature in tenths of Kelvins (5009)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating3StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.13.10.2
Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating3Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.13.11
OBJECT IDENTIFIER    

airIRmPmEheating3HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.13.11.1
Electric heater #3 hysteresis in tenths of Kelvins (5010)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating3HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.13.11.2
Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating3Runtime 1.3.6.1.4.1.318.1.1.13.5.3.13.17
Electric heater #3 runtime in hours (5016)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating4 1.3.6.1.4.1.318.1.1.13.5.3.14
OBJECT IDENTIFIER    

airIRmPmEheating4ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.14.2
Electric heater #4 manual operation enable (5101)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating4Running 1.3.6.1.4.1.318.1.1.13.5.3.14.4
Electric heater #4 running state (5103)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmEheating4ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.14.5
Electric heater #4 running in manual operation mode (5104)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmEheating4Type 1.3.6.1.4.1.318.1.1.13.5.3.14.9
Electric heater #4 type (5108)
OBJECT-TYPE    
  INTEGER direct(1), pwm(2)  

airIRmPmEheating4StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.14.10
OBJECT IDENTIFIER    

airIRmPmEheating4StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.14.10.1
Electric heater #4 start temperature in tenths of Kelvins (5109)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating4StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.14.10.2
Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating4Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.14.11
OBJECT IDENTIFIER    

airIRmPmEheating4HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.14.11.1
Electric heater #4 hysteresis in tenths of Kelvins (5110)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating4HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.14.11.2
Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110)
OBJECT-TYPE    
  INTEGER  

airIRmPmEheating4Runtime 1.3.6.1.4.1.318.1.1.13.5.3.14.17
Electric heater #4 runtime in hours (5116)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalve 1.3.6.1.4.1.318.1.1.13.5.3.15
OBJECT IDENTIFIER    

airIRmPmGECWvalveManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.15.2
GE/CW valve manual operation enable (5201)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveStartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.15.9
OBJECT IDENTIFIER    

airIRmPmGECWvalveStartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.15.9.1
GE/CW valve start temperature in tenths of Kelvins (5208)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveStartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.15.9.2
GE/CW valve start temperature in tenths of degrees Fahrenheit (5208)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveLinearRange 1.3.6.1.4.1.318.1.1.13.5.3.15.10
OBJECT IDENTIFIER    

airIRmPmGECWvalveLinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.15.10.1
GE/CW valve linear range in tenths of Kelvins (5209)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveLinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.15.10.2
GE/CW valve linear range in tenths of degrees Fahrenheit (5209)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveGEOffTemp 1.3.6.1.4.1.318.1.1.13.5.3.15.12
OBJECT IDENTIFIER    

airIRmPmGECWvalveGEOffTempC 1.3.6.1.4.1.318.1.1.13.5.3.15.12.1
GE/CW valve GE off temperature in tenths of degrees Celsius (5211)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveGEOffTempF 1.3.6.1.4.1.318.1.1.13.5.3.15.12.2
GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveOpeningGrade 1.3.6.1.4.1.318.1.1.13.5.3.15.15
GE/CW valve opening grade in percent (5214)
OBJECT-TYPE    
  INTEGER  

airIRmPmGECWvalveManOpOpeningGrade 1.3.6.1.4.1.318.1.1.13.5.3.15.16
GE/CW valve manual operation opening grade in percent (5215)
OBJECT-TYPE    
  INTEGER  

airIRmPmGvalve 1.3.6.1.4.1.318.1.1.13.5.3.16
OBJECT IDENTIFIER    

airIRmPmGvalveManOperationEnable 1.3.6.1.4.1.318.1.1.13.5.3.16.2
G-valve manual operation enable (5301)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmGvalvePreOpeningTime 1.3.6.1.4.1.318.1.1.13.5.3.16.11
G-valve pre-opening time in seconds (5310)
OBJECT-TYPE    
  INTEGER  

airIRmPmGvalvePreOpeningGrade 1.3.6.1.4.1.318.1.1.13.5.3.16.12
G-valve pre-opening grade in percent (5311)
OBJECT-TYPE    
  INTEGER  

airIRmPmGvalveOpeningGrade 1.3.6.1.4.1.318.1.1.13.5.3.16.13
G-valve opening grade in percent (5312)
OBJECT-TYPE    
  INTEGER  

airIRmPmGvalveManOpOpeningGrade 1.3.6.1.4.1.318.1.1.13.5.3.16.14
G-valve manual operation opening grade in percent (5313)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1 1.3.6.1.4.1.318.1.1.13.5.3.17
OBJECT IDENTIFIER    

airIRmPmDrycooler1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.17.2
Drycooler 1 manual operation enable setting (5401)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler1Running 1.3.6.1.4.1.318.1.1.13.5.3.17.3
Drycooler 1 running (5402)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler1ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.17.5
Drycooler 1 manual operation running (5404)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler1WinterStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.17.9
OBJECT IDENTIFIER    

airIRmPmDrycooler1WinterStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.17.9.1
Drycooler 1 winter mode start temperature in tenths of degrees Celsius (5408)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1WinterStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.17.9.2
Drycooler 1 winter mode start temperature in tenths of degrees Fahrenheit (5408)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1SummerStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.17.10
OBJECT IDENTIFIER    

airIRmPmDrycooler1SummerStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.17.10.1
Drycooler 1 summer mode start temperature in tenths of degrees Celsius (5409)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1SummerStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.17.10.2
Drycooler 1 summer mode start temperature in tenths of degrees Fahrenheit (5409)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.17.11
OBJECT IDENTIFIER    

airIRmPmDrycooler1HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.17.11.1
Drycooler 1 hysteresis in tenths of Kelvins (5410)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.17.11.2
Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.17.16
Drycooler 1 runtime in hours (5415)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2 1.3.6.1.4.1.318.1.1.13.5.3.18
OBJECT IDENTIFIER    

airIRmPmDrycooler2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.18.2
Drycooler 2 manual operation enable setting (5501)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler2Running 1.3.6.1.4.1.318.1.1.13.5.3.18.3
Drycooler 2 running (5502)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler2ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.18.5
Drycooler 2 manual operation running (5504)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler2WinterStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.18.9
OBJECT IDENTIFIER    

airIRmPmDrycooler2WinterStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.18.9.1
Drycooler 2 winter mode start temperature in tenths of degrees Celsius (5508)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2WinterStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.18.9.2
Drycooler 2 winter mode start temperature in tenths of degrees Fahrenheit (5508)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2SummerStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.18.10
OBJECT IDENTIFIER    

airIRmPmDrycooler2SummerStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.18.10.1
Drycooler 2 summer mode start temperature in tenths of degrees Celsius (5509)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2SummerStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.18.10.2
Drycooler 2 summer mode start temperature in tenths of degrees Fahrenheit (5509)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.18.11
OBJECT IDENTIFIER    

airIRmPmDrycooler2HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.18.11.1
Drycooler 2 hysteresis in tenths of Kelvins (5510)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.18.11.2
Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.18.16
Drycooler 2 runtime in hours (5515)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3 1.3.6.1.4.1.318.1.1.13.5.3.19
OBJECT IDENTIFIER    

airIRmPmDrycooler3ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.19.2
Drycooler 3 manual operation enable setting (5601)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler3Running 1.3.6.1.4.1.318.1.1.13.5.3.19.3
Drycooler 3 running (5602)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler3ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.19.5
Drycooler 3 manual operation running (5604)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler3WinterStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.19.9
OBJECT IDENTIFIER    

airIRmPmDrycooler3WinterStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.19.9.1
Drycooler 3 winter mode start temperature in tenths of degrees Celsius (5608)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3WinterStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.19.9.2
Drycooler 3 winter mode start temperature in tenths of degrees Fahrenheit (5608)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3SummerStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.19.10
OBJECT IDENTIFIER    

airIRmPmDrycooler3SummerStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.19.10.1
Drycooler 3 summer mode start temperature in tenths of degrees Celsius (5609)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3SummerStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.19.10.2
Drycooler 3 summer mode start temperature in tenths of degrees Fahrenheit (5609)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.19.11
OBJECT IDENTIFIER    

airIRmPmDrycooler3HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.19.11.1
Drycooler 3 hysteresis in tenths of Kelvins (5610)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.19.11.2
Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler3Runtime 1.3.6.1.4.1.318.1.1.13.5.3.19.16
Drycooler 3 runtime in hours (5615)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4 1.3.6.1.4.1.318.1.1.13.5.3.20
OBJECT IDENTIFIER    

airIRmPmDrycooler4ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.20.2
Drycooler 4 manual operation enable setting (5701)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler4Running 1.3.6.1.4.1.318.1.1.13.5.3.20.3
Drycooler 4 running (5702)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler4ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.20.5
Drycooler 4 manual operation running (5704)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDrycooler4WinterStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.20.9
OBJECT IDENTIFIER    

airIRmPmDrycooler4WinterStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.20.9.1
Drycooler 4 winter mode start temperature in tenths of degrees Celsius (5708)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4WinterStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.20.9.2
Drycooler 4 winter mode start temperature in tenths of degrees Fahrenheit (5708)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4SummerStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.20.10
OBJECT IDENTIFIER    

airIRmPmDrycooler4SummerStartTempC 1.3.6.1.4.1.318.1.1.13.5.3.20.10.1
Drycooler 4 summer mode start temperature in tenths of degrees Celsius (5709)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4SummerStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.20.10.2
Drycooler 4 summer mode start temperature in tenths of degrees Fahrenheit (5709)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.20.11
OBJECT IDENTIFIER    

airIRmPmDrycooler4HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.20.11.1
Drycooler 4 hysteresis in tenths of Kelvins (5710)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.20.11.2
Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710)
OBJECT-TYPE    
  INTEGER  

airIRmPmDrycooler4Runtime 1.3.6.1.4.1.318.1.1.13.5.3.20.16
Drycooler 4 runtime in hours (5715)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1 1.3.6.1.4.1.318.1.1.13.5.3.21
OBJECT IDENTIFIER    

airIRmPmPump1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.21.2
Pump 1 manual operation enable state (5801)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump1Running 1.3.6.1.4.1.318.1.1.13.5.3.21.3
Pump 1 running (5802)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump1ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.21.6
Pump 1 manual operation running (5805)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump1StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.21.10
OBJECT IDENTIFIER    

airIRmPmPump1StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.21.10.1
Pump 1 starting temperature in tenths of Kelvins (5809)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.21.10.2
Pump 1 starting temperature in tenths of degrees Fahrenheit (5809)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.21.11
OBJECT IDENTIFIER    

airIRmPmPump1HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.21.11.1
Pump 1 hysteresis in tenths of Kelvins (5810)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.21.11.2
Pump 1 hysteresis in tenths of degrees Fahrenheit (5810)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.21.12
OBJECT IDENTIFIER    

airIRmPmPump1LinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.21.12.1
Pump 1 linear range in tenths of Kelvins (5811)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1LinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.21.12.2
Pump 1 linear range in tenths of degrees Fahrenheit (5811)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1PressureSetpoint 1.3.6.1.4.1.318.1.1.13.5.3.21.13
Pump 1 pressure setpoint in tenths of Bars (5812)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.21.21
Pump 1 runtime in hours (5820)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1Speed 1.3.6.1.4.1.318.1.1.13.5.3.21.22
Pump 1 speed in percent (5821)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1ControlCycle 1.3.6.1.4.1.318.1.1.13.5.3.21.28
Pump 1 control cycle length in seconds (5827)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1MaxAdjust 1.3.6.1.4.1.318.1.1.13.5.3.21.29
Pump 1 maximum adjustment in percent (5828)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump1ControlFactor 1.3.6.1.4.1.318.1.1.13.5.3.21.30
Pump 1 control factor setting (5829)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2 1.3.6.1.4.1.318.1.1.13.5.3.22
OBJECT IDENTIFIER    

airIRmPmPump2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.22.2
Pump 2 manual operation enable state (5901)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump2Running 1.3.6.1.4.1.318.1.1.13.5.3.22.3
Pump 2 running (5902)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump2ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.22.6
Pump 2 manual operation running (5905)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump2StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.22.10
OBJECT IDENTIFIER    

airIRmPmPump2StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.22.10.1
Pump 2 starting temperature in tenths of Kelvins (5909)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.22.10.2
Pump 2 starting temperature in tenths of degrees Fahrenheit (5909)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.22.11
OBJECT IDENTIFIER    

airIRmPmPump2HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.22.11.1
Pump 2 hysteresis in tenths of Kelvins (5910)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.22.11.2
Pump 2 hysteresis in tenths of degrees Fahrenheit (5910)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.22.12
OBJECT IDENTIFIER    

airIRmPmPump2LinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.22.12.1
Pump 2 linear range in tenths of Kelvins (5911)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2LinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.22.12.2
Pump 2 linear range in tenths of degrees Fahrenheit (5911)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2PressureSetpoint 1.3.6.1.4.1.318.1.1.13.5.3.22.13
Pump 2 pressure setpoint in tenths of Bars (5912)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.22.21
Pump 2 runtime in hours (5920)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2Speed 1.3.6.1.4.1.318.1.1.13.5.3.22.22
Pump 2 speed in percent (5921)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2ControlCycle 1.3.6.1.4.1.318.1.1.13.5.3.22.28
Pump 2 control cycle length in seconds (5927)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2MaxAdjust 1.3.6.1.4.1.318.1.1.13.5.3.22.29
Pump 2 maximum adjustment in percent (5928)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump2ControlFactor 1.3.6.1.4.1.318.1.1.13.5.3.22.30
Pump 2 control factor setting (5929)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3 1.3.6.1.4.1.318.1.1.13.5.3.23
OBJECT IDENTIFIER    

airIRmPmPump3ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.23.2
Pump 3 manual operation enable state (6001)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump3Running 1.3.6.1.4.1.318.1.1.13.5.3.23.3
Pump 3 running (6002)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump3ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.23.6
Pump 3 manual operation running (6005)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump3StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.23.10
OBJECT IDENTIFIER    

airIRmPmPump3StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.23.10.1
Pump 3 starting temperature in tenths of Kelvins (6009)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.23.10.2
Pump 3 starting temperature in tenths of degrees Fahrenheit (6009)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.23.11
OBJECT IDENTIFIER    

airIRmPmPump3HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.23.11.1
Pump 3 hysteresis in tenths of Kelvins (6010)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.23.11.2
Pump 3 hysteresis in tenths of degrees Fahrenheit (6010)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.23.12
OBJECT IDENTIFIER    

airIRmPmPump3LinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.23.12.1
Pump 3 linear range in tenths of Kelvins (6011)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3LinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.23.12.2
Pump 3 linear range in tenths of degrees Fahrenheit (6011)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3PressureSetpoint 1.3.6.1.4.1.318.1.1.13.5.3.23.13
Pump 3 pressure setpoint in tenths of Bars (6012)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3Runtime 1.3.6.1.4.1.318.1.1.13.5.3.23.21
Pump 3 runtime in hours (6020)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3Speed 1.3.6.1.4.1.318.1.1.13.5.3.23.22
Pump 3 speed in percent (6021)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3ControlCycle 1.3.6.1.4.1.318.1.1.13.5.3.23.28
Pump 3 control cycle length in seconds (6027)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3MaxAdjust 1.3.6.1.4.1.318.1.1.13.5.3.23.29
Pump 3 maximum adjustment in percent (6028)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump3ControlFactor 1.3.6.1.4.1.318.1.1.13.5.3.23.30
Pump 3 control factor setting (6029)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4 1.3.6.1.4.1.318.1.1.13.5.3.24
OBJECT IDENTIFIER    

airIRmPmPump4ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.24.2
Pump 4 manual operation enable state (6101)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump4Running 1.3.6.1.4.1.318.1.1.13.5.3.24.3
Pump 4 running (6102)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump4ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.24.6
Pump 4 manual operation running (6105)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPump4StartTemperature 1.3.6.1.4.1.318.1.1.13.5.3.24.10
OBJECT IDENTIFIER    

airIRmPmPump4StartTemperatureK 1.3.6.1.4.1.318.1.1.13.5.3.24.10.1
Pump 4 starting temperature in tenths of Kelvins (6109)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4StartTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.24.10.2
Pump 4 starting temperature in tenths of degrees Fahrenheit (6109)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.24.11
OBJECT IDENTIFIER    

airIRmPmPump4HysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.24.11.1
Pump 4 hysteresis in tenths of Kelvins (6110)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4HysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.24.11.2
Pump 4 hysteresis in tenths of degrees Fahrenheit (6110)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.24.12
OBJECT IDENTIFIER    

airIRmPmPump4LinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.24.12.1
Pump 4 linear range in tenths of Kelvins (6111)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4LinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.24.12.2
Pump 4 linear range in tenths of degrees Fahrenheit (6111)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4PressureSetpoint 1.3.6.1.4.1.318.1.1.13.5.3.24.13
Pump 4 pressure setpoint in tenths of Bars (6112)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4Runtime 1.3.6.1.4.1.318.1.1.13.5.3.24.21
Pump 4 runtime in hours (6120)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4Speed 1.3.6.1.4.1.318.1.1.13.5.3.24.22
Pump 4 speed in percent (6121)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4ControlCycle 1.3.6.1.4.1.318.1.1.13.5.3.24.28
Pump 4 control cycle length in seconds (6127)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4MaxAdjust 1.3.6.1.4.1.318.1.1.13.5.3.24.29
Pump 4 maximum adjustment in percent (6128)
OBJECT-TYPE    
  INTEGER  

airIRmPmPump4ControlFactor 1.3.6.1.4.1.318.1.1.13.5.3.24.30
Pump 4 control factor setting (6129)
OBJECT-TYPE    
  INTEGER  

airIRmPmHotgasHeating 1.3.6.1.4.1.318.1.1.13.5.3.25
OBJECT IDENTIFIER    

airIRmPmHotgasHeatRunning 1.3.6.1.4.1.318.1.1.13.5.3.25.3
Hotgas heat running state. (6202)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmPWWHeating 1.3.6.1.4.1.318.1.1.13.5.3.26
OBJECT IDENTIFIER    

airIRmPmPWWHeatingManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.26.2
PWW-heating manual operation enable (6301)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPWWHeatingRunning 1.3.6.1.4.1.318.1.1.13.5.3.26.3
PWW-heating running (6302)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPWWHeatingManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.26.4
PWW-heating manual operation running (6303)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmPWWHeatingType 1.3.6.1.4.1.318.1.1.13.5.3.26.9
PWW-heating type (6308)
OBJECT-TYPE    
  INTEGER direct(1), undefined(2)  

airIRmPmPWWHeatingStartTemp 1.3.6.1.4.1.318.1.1.13.5.3.26.10
OBJECT IDENTIFIER    

airIRmPmPWWHeatingStartTempK 1.3.6.1.4.1.318.1.1.13.5.3.26.10.1
PWW-heating starting temperature in Kelvins (6309)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingStartTempF 1.3.6.1.4.1.318.1.1.13.5.3.26.10.2
PWW-heating starting temperature in degrees Fahrenheit (6309)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingHysteresis 1.3.6.1.4.1.318.1.1.13.5.3.26.12
OBJECT IDENTIFIER    

airIRmPmPWWHeatingHysteresisK 1.3.6.1.4.1.318.1.1.13.5.3.26.12.1
PWW-heating hysteresis in Kelvins (6311)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingHysteresisF 1.3.6.1.4.1.318.1.1.13.5.3.26.12.2
PWW-heating hysteresis in degrees Fahrenheit (6311)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingLinearRange 1.3.6.1.4.1.318.1.1.13.5.3.26.13
OBJECT IDENTIFIER    

airIRmPmPWWHeatingLinearRangeK 1.3.6.1.4.1.318.1.1.13.5.3.26.13.1
PWW-heating linear range in Kelvins (6312)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingLinearRangeF 1.3.6.1.4.1.318.1.1.13.5.3.26.13.2
PWW-heating linear range in degrees Fahrenheit (6312)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingCurrentValue 1.3.6.1.4.1.318.1.1.13.5.3.26.16
PWW-heating current value in percent (6315)
OBJECT-TYPE    
  INTEGER  

airIRmPmPWWHeatingManOpValue 1.3.6.1.4.1.318.1.1.13.5.3.26.17
PWW-heating manual operation value in percent (6316)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1 1.3.6.1.4.1.318.1.1.13.5.3.27
OBJECT IDENTIFIER    

airIRmPmHumidifier1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.27.2
Humidifier #1 manual operation enable (6401)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmHumidifier1Running 1.3.6.1.4.1.318.1.1.13.5.3.27.3
Humidifier #1 running state (6402)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmHumidifier1ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.27.5
Humidifier #1 manual operation running state (6404)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmHumidifier1Type 1.3.6.1.4.1.318.1.1.13.5.3.27.17
Humidifier #1 type (6416)
OBJECT-TYPE    
  INTEGER direct(1), proportional(2)  

airIRmPmHumidifier1StartHumidity 1.3.6.1.4.1.318.1.1.13.5.3.27.18
Humidifier #1 start humidity in tenths of percent relative humidity (6417)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.27.20
Humidifier #1 hysteresis in tenths of percent relative humidity (6419)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.27.21
Humidifier #1 linear range in tenths of percent relative humidity per Kelvin (6420)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.27.27
Humidifier #1 runtime in hours (6426)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1CurrentValue 1.3.6.1.4.1.318.1.1.13.5.3.27.28
Humidifier #1 current value in percent (6427)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier1ManOpValue 1.3.6.1.4.1.318.1.1.13.5.3.27.29
Humidifier #1 manual operation value in percent (6428)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2 1.3.6.1.4.1.318.1.1.13.5.3.28
OBJECT IDENTIFIER    

airIRmPmHumidifier2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.28.2
Humidifier #2 manual operation enable (6501)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmHumidifier2Running 1.3.6.1.4.1.318.1.1.13.5.3.28.3
Humidifier #2 running state (6502)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmHumidifier2ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.28.5
Humidifier #2 manual operation running state (6504)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmHumidifier2Type 1.3.6.1.4.1.318.1.1.13.5.3.28.17
Humidifier #2 type (6516)
OBJECT-TYPE    
  INTEGER direct(1), proportional(2)  

airIRmPmHumidifier2StartHumidity 1.3.6.1.4.1.318.1.1.13.5.3.28.18
Humidifier #2 start humidity in tenths of percent relative humidity (6517)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2Hysteresis 1.3.6.1.4.1.318.1.1.13.5.3.28.20
Humidifier #2 hysteresis in tenths of percent relative humidity (6519)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2LinearRange 1.3.6.1.4.1.318.1.1.13.5.3.28.21
Humidifier #2 linear range in tenths of percent relative humidity per Kelvin (6520)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.28.27
Humidifier #2 runtime in hours (6526)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2CurrentValue 1.3.6.1.4.1.318.1.1.13.5.3.28.28
Humidifier #2 current value in percent (6527)
OBJECT-TYPE    
  INTEGER  

airIRmPmHumidifier2ManOpValue 1.3.6.1.4.1.318.1.1.13.5.3.28.29
Humidifier #2 manual operation value in percent (6528)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidification 1.3.6.1.4.1.318.1.1.13.5.3.31
OBJECT IDENTIFIER    

airIRmPmDehumidificManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.31.2
Dehumidifier manual operation enable setting (6801)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDehumidificRunning 1.3.6.1.4.1.318.1.1.13.5.3.31.3
Dehumidifier running state (6802)
OBJECT-TYPE    
  AirIRmControlState  

airIRmPmDehumidificManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.31.5
Dehumidifier manual operation running (6804)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmDehumidificStartHumidity 1.3.6.1.4.1.318.1.1.13.5.3.31.10
Dehumidifier start humidity in tenths of percent relative humidity (6809)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificHysteresis 1.3.6.1.4.1.318.1.1.13.5.3.31.12
Dehumidifier hysteresis in tenths of percent relative humidity (6811)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificMinWaterTemp 1.3.6.1.4.1.318.1.1.13.5.3.31.18
OBJECT IDENTIFIER    

airIRmPmDehumidificMinWaterTempC 1.3.6.1.4.1.318.1.1.13.5.3.31.18.1
Dehumidifier minimum water temperature in tenths of degrees Celsius (6817)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificMinWaterTempF 1.3.6.1.4.1.318.1.1.13.5.3.31.18.2
Dehumidifier minimum water temperature in tenths of degrees Fahrenheit (6817)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificMaxWaterTemp 1.3.6.1.4.1.318.1.1.13.5.3.31.19
OBJECT IDENTIFIER    

airIRmPmDehumidificMaxWaterTempC 1.3.6.1.4.1.318.1.1.13.5.3.31.19.1
Dehumidifier maximum water temperature in tenths of degrees Celsius (6818)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificMaxWaterTempF 1.3.6.1.4.1.318.1.1.13.5.3.31.19.2
Dehumidifier maximum water temperature in tenths of degrees Fahrenheit (6818)
OBJECT-TYPE    
  INTEGER  

airIRmPmDehumidificRuntime 1.3.6.1.4.1.318.1.1.13.5.3.31.21
Dehumidifier runtime in hours (6820)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan1 1.3.6.1.4.1.318.1.1.13.5.3.32
OBJECT IDENTIFIER    

airIRmPmFan1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.32.2
Fan 1 manual operation enable (6901)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan1Running 1.3.6.1.4.1.318.1.1.13.5.3.32.3
Fan 1 running (6902)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan1ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.32.6
Fan 1 manual operation running (6905)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan1Type 1.3.6.1.4.1.318.1.1.13.5.3.32.9
Fan 1 type (6908)
OBJECT-TYPE    
  INTEGER direct(1), proportional(2)  

airIRmPmFan1Runtime 1.3.6.1.4.1.318.1.1.13.5.3.32.32
Fan 1 runtime in hours (6931)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan1Speed 1.3.6.1.4.1.318.1.1.13.5.3.32.33
Fan 1 speed in percent (6932)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan1ManOpSpeed 1.3.6.1.4.1.318.1.1.13.5.3.32.34
Fan 1 manual operation speed in percent (6933)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan2 1.3.6.1.4.1.318.1.1.13.5.3.33
OBJECT IDENTIFIER    

airIRmPmFan2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.33.2
Fan 1 manual operation enable (7001)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan2Running 1.3.6.1.4.1.318.1.1.13.5.3.33.3
Fan 1 running (7002)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan2ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.33.6
Fan 1 manual operation running (7005)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan2Type 1.3.6.1.4.1.318.1.1.13.5.3.33.9
Fan 2 type (7008)
OBJECT-TYPE    
  INTEGER direct(1), proportional(2)  

airIRmPmFan2Runtime 1.3.6.1.4.1.318.1.1.13.5.3.33.32
Fan 1 runtime in hours (7031)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan2Speed 1.3.6.1.4.1.318.1.1.13.5.3.33.33
Fan 1 speed in percent (7032)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan2ManOpSpeed 1.3.6.1.4.1.318.1.1.13.5.3.33.34
Fan 1 manual operation speed in percent (7033)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan3 1.3.6.1.4.1.318.1.1.13.5.3.34
OBJECT IDENTIFIER    

airIRmPmFan3ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.34.2
Fan 1 manual operation enable (7101)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan3Running 1.3.6.1.4.1.318.1.1.13.5.3.34.3
Fan 1 running (7102)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan3ManOpRunning 1.3.6.1.4.1.318.1.1.13.5.3.34.6
Fan 1 manual operation running (7105)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmFan3Type 1.3.6.1.4.1.318.1.1.13.5.3.34.9
Fan 3 type (7108)
OBJECT-TYPE    
  INTEGER direct(1), proportional(2)  

airIRmPmFan3Runtime 1.3.6.1.4.1.318.1.1.13.5.3.34.32
Fan 1 runtime in hours (7131)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan3Speed 1.3.6.1.4.1.318.1.1.13.5.3.34.33
Fan 1 speed in percent (7132)
OBJECT-TYPE    
  INTEGER  

airIRmPmFan3ManOpSpeed 1.3.6.1.4.1.318.1.1.13.5.3.34.34
Fan 1 manual operation speed in percent (7133)
OBJECT-TYPE    
  INTEGER  

airIRmPmLouver1 1.3.6.1.4.1.318.1.1.13.5.3.35
OBJECT IDENTIFIER    

airIRmPmLouver1ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.35.2
Louver 1 manual operation enable (7201)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmLouver1Position 1.3.6.1.4.1.318.1.1.13.5.3.35.3
Louver 1 position (7202)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmLouver1ManOpPosition 1.3.6.1.4.1.318.1.1.13.5.3.35.4
Louver 1 manual operation position setting (7203)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmLouver2 1.3.6.1.4.1.318.1.1.13.5.3.36
OBJECT IDENTIFIER    

airIRmPmLouver2ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.36.2
Louver 2 manual operation enable (7301)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmLouver2Position 1.3.6.1.4.1.318.1.1.13.5.3.36.3
Louver 2 position (7302)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmLouver2ManOpPosition 1.3.6.1.4.1.318.1.1.13.5.3.36.4
Louver 2 manual operation position setting (7303)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmLouver3 1.3.6.1.4.1.318.1.1.13.5.3.37
OBJECT IDENTIFIER    

airIRmPmLouver3ManOpEnable 1.3.6.1.4.1.318.1.1.13.5.3.37.2
Louver 3 manual operation enable (7401)
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmLouver3Position 1.3.6.1.4.1.318.1.1.13.5.3.37.3
Louver 3 position (7402)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmLouver3ManOpPosition 1.3.6.1.4.1.318.1.1.13.5.3.37.4
Louver 3 manual operation position setting (7403)
OBJECT-TYPE    
  INTEGER closed(1), open(2)  

airIRmPmAuxAlarm1 1.3.6.1.4.1.318.1.1.13.5.3.38
OBJECT IDENTIFIER    

airIRmPmAuxAlarm2 1.3.6.1.4.1.318.1.1.13.5.3.39
OBJECT IDENTIFIER    

airIRmPmAuxAlarm3 1.3.6.1.4.1.318.1.1.13.5.3.40
OBJECT IDENTIFIER    

airIRmPmAuxAlarm4 1.3.6.1.4.1.318.1.1.13.5.3.41
OBJECT IDENTIFIER    

airIRmPmAuxAlarm5 1.3.6.1.4.1.318.1.1.13.5.3.42
OBJECT IDENTIFIER    

airIRmPmAlarmBits 1.3.6.1.4.1.318.1.1.13.5.3.43
OBJECT IDENTIFIER    

airIRmPmFan1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.1
Fan #1 failure (8500).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFan2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.2
Fan #2 failure (8501).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFan3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.3
Fan #3 failure (8502).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.4
Compressor #1 failure (8503).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.5
Compressor #2 failure (8504).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmWaterDetector 1.3.6.1.4.1.318.1.1.13.5.3.43.6
Water detector alarm (8505).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmPhaseFailure 1.3.6.1.4.1.318.1.1.13.5.3.43.7
Phase failure (8506).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFireSmokeDetector 1.3.6.1.4.1.318.1.1.13.5.3.43.8
Fire/smoke detector (8507).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReturnAirTemperatureTooHigh 1.3.6.1.4.1.318.1.1.13.5.3.43.9
Return air temperature too high (8508).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReturnAirHumidityTooHigh 1.3.6.1.4.1.318.1.1.13.5.3.43.10
Return air humidity too high (8509).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSupplyAirTemperatureTooHigh 1.3.6.1.4.1.318.1.1.13.5.3.43.11
Supply air temperature too high (8510).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSupplyAirHumidityTooHigh 1.3.6.1.4.1.318.1.1.13.5.3.43.12
Supply air humidity too high (8511).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmWaterTemperatureTooHigh 1.3.6.1.4.1.318.1.1.13.5.3.43.13
Water temperature too high (8512).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReturnAirTemperatureTooLow 1.3.6.1.4.1.318.1.1.13.5.3.43.14
Return air temperature too low (8513).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReturnAirHumidityTooLow 1.3.6.1.4.1.318.1.1.13.5.3.43.15
Return air humidity too low (8514).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSupplyAirTemperatureTooLow 1.3.6.1.4.1.318.1.1.13.5.3.43.16
Supply air temperature too low (8515).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSupplyAirHumidityTooLow 1.3.6.1.4.1.318.1.1.13.5.3.43.17
Supply air humidity too low (8516).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmWaterTemperatureTooLow 1.3.6.1.4.1.318.1.1.13.5.3.43.18
Water temperature too low (8517).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.19
Sensor #1 failure (8518).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.20
Sensor #2 failure (8519).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.21
Sensor #3 failure (8520).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor4Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.22
Sensor #4 failure (8521).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor5Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.23
Sensor #5 failure (8522).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor6Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.24
Sensor #6 failure (8523).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor7Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.25
Sensor #7 failure (8524).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor8Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.26
Sensor #8 failure (8525).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor9Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.27
Sensor #9 failure (8526).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor10Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.28
Sensor #10 failure (8527).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor11Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.29
Sensor #11 failure (8528).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor12Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.30
Sensor #12 failure (8529).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor13Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.31
Sensor #13 failure (8530).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor14Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.32
Sensor #14 failure (8531).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor15Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.33
Sensor #15 failure (8532).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor16Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.34
Sensor #16 failure (8533).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor17Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.35
Sensor #17 failure (8534).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor18Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.36
Sensor #18 failure (8535).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor19Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.37
Sensor #19 failure (8536).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor20Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.38
Sensor #20 failure (8537).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor21Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.39
Sensor #21 failure (8538).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor1Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.40
Sensor #1 defect (8539).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor2Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.41
Sensor #2 defect (8540).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor3Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.42
Sensor #3 defect (8541).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor4Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.43
Sensor #4 defect (8542).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor5Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.44
Sensor #5 defect (8543).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor6Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.45
Sensor #6 defect (8544).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor7Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.46
Sensor #7 defect (8545).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor8Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.47
Sensor #8 defect (8546).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor9Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.48
Sensor #9 defect (8547).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor10Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.49
Sensor #10 defect (8548).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor11Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.50
Sensor #11 defect (8549).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor12Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.51
Sensor #12 defect (8550).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor13Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.52
Sensor #13 defect (8551).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor14Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.53
Sensor #14 defect (8552).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor15Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.54
Sensor #15 defect (8553).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor16Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.55
Sensor #16 defect (8554).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor17Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.56
Sensor #17 defect (8555).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor18Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.57
Sensor #18 defect (8556)
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor19Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.58
Sensor #19 defect (8557).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor20Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.59
Sensor #20 defect (8558).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmSensor21Defect 1.3.6.1.4.1.318.1.1.13.5.3.43.60
Sensor #21 defect (8559).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor1Alarm 1.3.6.1.4.1.318.1.1.13.5.3.43.61
Compressor #1 alarm (8560).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor2Alarm 1.3.6.1.4.1.318.1.1.13.5.3.43.62
Compressor #2 alarm (8561).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor1LowPressure 1.3.6.1.4.1.318.1.1.13.5.3.43.63
Compressor #1 low pressure (8562).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmCompressor2LowPressure 1.3.6.1.4.1.318.1.1.13.5.3.43.64
Compressor #2 low pressure (8563).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReheat1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.65
Reheat #1 failure (8564).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReheat2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.66
Reheat #2 failure (8565).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReheat3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.67
Reheat #3 failure (8566).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmReheat4Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.68
Reheat #4 failure (8567).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmDrycooler1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.69
Drycooler #1 failure (8568).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmDrycooler2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.70
Drycooler #2 failure (8569).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmDrycooler3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.71
Drycooler #3 failure (8570).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmDrycooler4Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.72
Drycooler #4 failure (8571).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmPump1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.73
Pump #1 failure (8572).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmPump2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.74
Pump #2 failure (8573).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmPump3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.75
Pump #3 failure (8574).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmPump4Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.76
Pump #4 failure (8575).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier1Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.77
Humidifier #1 failure (8576).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier2Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.78
Humidifier #2 failure (8577).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier3Failure 1.3.6.1.4.1.318.1.1.13.5.3.43.79
Humidifier #3 failure (8578).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier1Alarm5us 1.3.6.1.4.1.318.1.1.13.5.3.43.80
Humidifier #1 5us alarm (8579).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier2Alarm5us 1.3.6.1.4.1.318.1.1.13.5.3.43.81
Humidifier #2 5us alarm (8580).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier3Alarm5us 1.3.6.1.4.1.318.1.1.13.5.3.43.82
Humidifier #3 5us alarm (8581).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier1Alarm20us 1.3.6.1.4.1.318.1.1.13.5.3.43.83
Humidifier #1 20us alarm (8582).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier2Alarm20us 1.3.6.1.4.1.318.1.1.13.5.3.43.84
Humidifier #2 20us alarm (8583).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHumidifier3Alarm20us 1.3.6.1.4.1.318.1.1.13.5.3.43.85
Humidifier #3 20us alarm (8584).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFan1Alarm 1.3.6.1.4.1.318.1.1.13.5.3.43.86
Fan #1 alarm (8585).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFan2Alarm 1.3.6.1.4.1.318.1.1.13.5.3.43.87
Fan #2 alarm (8586).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFan3Alarm 1.3.6.1.4.1.318.1.1.13.5.3.43.88
Fan #3 alarm (8587).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFilter1Clogged 1.3.6.1.4.1.318.1.1.13.5.3.43.89
Filter #1 clogged (8588).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFilter2Clogged 1.3.6.1.4.1.318.1.1.13.5.3.43.90
Filter #2 clogged (8589).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmFilter3Clogged 1.3.6.1.4.1.318.1.1.13.5.3.43.91
Filter #3 clogged (8590).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm1 1.3.6.1.4.1.318.1.1.13.5.3.43.92
Auxiliary #1 alarm (8591).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm2 1.3.6.1.4.1.318.1.1.13.5.3.43.93
Auxiliary #2 alarm (8592).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm3 1.3.6.1.4.1.318.1.1.13.5.3.43.94
Auxiliary #3 alarm (8593).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm4 1.3.6.1.4.1.318.1.1.13.5.3.43.95
Auxiliary #4 alarm (8594).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm5 1.3.6.1.4.1.318.1.1.13.5.3.43.96
Auxiliary #5 alarm (8595).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm6 1.3.6.1.4.1.318.1.1.13.5.3.43.97
Auxiliary #6 alarm (8596).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm7 1.3.6.1.4.1.318.1.1.13.5.3.43.98
Auxiliary #7 alarm (8597).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm8 1.3.6.1.4.1.318.1.1.13.5.3.43.99
Auxiliary #8 alarm (8598).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm9 1.3.6.1.4.1.318.1.1.13.5.3.43.100
Auxiliary #9 alarm (8599).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmAuxiliaryAlarm10 1.3.6.1.4.1.318.1.1.13.5.3.43.101
Auxiliary #10 alarm (8600).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmHotGasHeatingAlarm 1.3.6.1.4.1.318.1.1.13.5.3.43.102
Hot gas heating alarm (8601).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV1PressureSensorError 1.3.6.1.4.1.318.1.1.13.5.3.43.103
EEV1 pressure sensor error (8602).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV1TemperatureSensorError 1.3.6.1.4.1.318.1.1.13.5.3.43.104
EEV1 temperature sensor error (8603).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV1StepperMotorError 1.3.6.1.4.1.318.1.1.13.5.3.43.105
EEV1 stepper motor error (8604).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV2PressureSensorError 1.3.6.1.4.1.318.1.1.13.5.3.43.106
EEV2 pressure sensor error (8605).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV2TemperatureSensorError 1.3.6.1.4.1.318.1.1.13.5.3.43.107
EEV2 temperature sensor error (8606).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmEEV2StepperMotorError 1.3.6.1.4.1.318.1.1.13.5.3.43.108
EEV2 stepper motor error (8607).
OBJECT-TYPE    
  AirIRmAlarmState  

airIRmPmMyZone 1.3.6.1.4.1.318.1.1.13.5.3.44
OBJECT IDENTIFIER    

airIRmPmMyZoneNumber 1.3.6.1.4.1.318.1.1.13.5.3.44.1
My zone number (11700).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneRoomTemperature 1.3.6.1.4.1.318.1.1.13.5.3.44.2
OBJECT IDENTIFIER    

airIRmPmMyZoneRoomTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.44.2.1
My zone room temperature in tenths of degrees Celsius (11701).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneRoomTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.44.2.2
My zone room temperature in tenths of degrees Fahrenheit (11701).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneRoomHumidity 1.3.6.1.4.1.318.1.1.13.5.3.44.3
My zone room humidity in tenths of %RH (11702).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneSupplyTemperature 1.3.6.1.4.1.318.1.1.13.5.3.44.4
OBJECT IDENTIFIER    

airIRmPmMyZoneSupplyTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.44.4.1
My zone supply temperature in tenths of degrees Celsius (11703).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneSupplyTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.44.4.2
My zone supply temperature in tenths of degrees Fahrenheit (11703).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneSupplyHumidity 1.3.6.1.4.1.318.1.1.13.5.3.44.5
My zone supply humidity in tenths of %RH (11704).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneSequencingTime 1.3.6.1.4.1.318.1.1.13.5.3.44.6
My zone sequencing time in minutes (11705).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneNumberOfErrorUnits 1.3.6.1.4.1.318.1.1.13.5.3.44.7
Number of error units in my zone (11706).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneEmergencyTemperature 1.3.6.1.4.1.318.1.1.13.5.3.44.8
OBJECT IDENTIFIER    

airIRmPmMyZoneEmergencyTemperatureC 1.3.6.1.4.1.318.1.1.13.5.3.44.8.1
My zone emergency temperature in tenths of degrees Celsius (11707).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneEmergencyTemperatureF 1.3.6.1.4.1.318.1.1.13.5.3.44.8.2
My zone emergency temperature in tenths of degrees Fahrenheit (11707).
OBJECT-TYPE    
  INTEGER  

airIRmPmMyZoneCWEnergySaveMode 1.3.6.1.4.1.318.1.1.13.5.3.44.9
My zone CW energy save mode (11708).
OBJECT-TYPE    
  AirIRmActivityState  

airIRmPmGlobalZoneData 1.3.6.1.4.1.318.1.1.13.5.3.45
OBJECT IDENTIFIER    

airIRmPmGlobalZoneDataEmergencyOpMode 1.3.6.1.4.1.318.1.1.13.5.3.45.1
Emergency operation mode (11800).
OBJECT-TYPE    
  AirIRmActivityState  

airIRGen3 1.3.6.1.4.1.318.1.1.13.6
OBJECT IDENTIFIER    

airIRG3Ident 1.3.6.1.4.1.318.1.1.13.6.1
OBJECT IDENTIFIER    

airIRG3IdentTableSize 1.3.6.1.4.1.318.1.1.13.6.1.1
The ident table size.
OBJECT-TYPE    
  INTEGER  

airIRG3IdentTable 1.3.6.1.4.1.318.1.1.13.6.1.2
Allows to get ident information of current RDU and its assigned CM's.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3IdentEntry

airIRG3IdentEntry 1.3.6.1.4.1.318.1.1.13.6.1.2.1
The ident table entry.
OBJECT-TYPE    
  AirIRG3IdentEntry  

airIRG3IdentIndex 1.3.6.1.4.1.318.1.1.13.6.1.2.1.1
Index of ident table.
OBJECT-TYPE    
  INTEGER  

airIRG3IdentName 1.3.6.1.4.1.318.1.1.13.6.1.2.1.2
A character string identifying the unit name.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentLocation 1.3.6.1.4.1.318.1.1.13.6.1.2.1.3
A character string identifying the unit location.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentModelNumber 1.3.6.1.4.1.318.1.1.13.6.1.2.1.4
A character string identifying the unit model number.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentSerialNumber 1.3.6.1.4.1.318.1.1.13.6.1.2.1.5
A character string identifying the unit serial number.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentFirmwareRevision 1.3.6.1.4.1.318.1.1.13.6.1.2.1.6
A character string identifying the unit firmware version.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentHardwareRevision 1.3.6.1.4.1.318.1.1.13.6.1.2.1.7
A character string identifying the unit controller hardware revision.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentManufactureDate 1.3.6.1.4.1.318.1.1.13.6.1.2.1.8
A character string identifying the unit manufacture date.
OBJECT-TYPE    
  DisplayString  

airIRG3IdentRDUSysOID 1.3.6.1.4.1.318.1.1.13.6.1.2.1.9
This OID contains an OID path to the RDU data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRG3IdentCMSysOID 1.3.6.1.4.1.318.1.1.13.6.1.2.1.10
This OID contains an OID path to the cooling module data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRG3IdentGroupSysOID 1.3.6.1.4.1.318.1.1.13.6.1.2.1.11
This OID contains an OID path to the group data.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

airIRG3Group 1.3.6.1.4.1.318.1.1.13.6.2
OBJECT IDENTIFIER    

airIRG3GroupTableSize 1.3.6.1.4.1.318.1.1.13.6.2.1
The group table size.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusTable 1.3.6.1.4.1.318.1.1.13.6.2.2
Allows to get group status information.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3GroupStatusEntry

airIRG3GroupStatusEntry 1.3.6.1.4.1.318.1.1.13.6.2.2.1
The group staus table entry.
OBJECT-TYPE    
  AirIRG3GroupStatusEntry  

airIRG3GroupStatusIndex 1.3.6.1.4.1.318.1.1.13.6.2.2.1.1
Index of group status table.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusCoolOutput 1.3.6.1.4.1.318.1.1.13.6.2.2.1.2
The group cooling output in tenths of kilowatts (kW). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusCoolDemand 1.3.6.1.4.1.318.1.1.13.6.2.2.1.3
The group cooling demand in tenths of kilowatts (kW). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAirFlowUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.4
The group air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAirFlowMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.5
The group air flow in liters per second (L/s). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMaxRackInletTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.6
The group maximum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMaxRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.7
The group maximum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMinRackInletTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.8
The group minimum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMinRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.9
The group minimum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMaxReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.10
The group maximum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMaxReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.11
The group maximum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMinReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.12
The group minimum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusMinReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.13
The group minimum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgSupplyTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.14
The group average supply air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgSupplyTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.15
The group average supply air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgReturnTempUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.16
The group average return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgReturnTempMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.17
The group average return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgFanSpeed 1.3.6.1.4.1.318.1.1.13.6.2.2.1.18
The group average fan speed in revolutions per minute (RPM). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgAirFlowUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.19
The group average air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusAvgAirFlowMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.20
The group average air flow in liters per second (L/s). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusTotalAirFlowUS 1.3.6.1.4.1.318.1.1.13.6.2.2.1.21
The group total air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupStatusTotalAirFlowMetric 1.3.6.1.4.1.318.1.1.13.6.2.2.1.22
The group total air flow in liters per second (L/s). Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsTable 1.3.6.1.4.1.318.1.1.13.6.2.3
Allows to access the group setpoints.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3GroupSetpointsEntry

airIRG3GroupSetpointsEntry 1.3.6.1.4.1.318.1.1.13.6.2.3.1
The group setpoints table entry.
OBJECT-TYPE    
  AirIRG3GroupSetpointsEntry  

airIRG3GroupSetpointsIndex 1.3.6.1.4.1.318.1.1.13.6.2.3.1.1
Index of group setpoints table.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsCoolSetpointUS 1.3.6.1.4.1.318.1.1.13.6.2.3.1.2
Group cooling setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsCoolSetpointMetric 1.3.6.1.4.1.318.1.1.13.6.2.3.1.3
Group cooling setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsCoolDeadbandUS 1.3.6.1.4.1.318.1.1.13.6.2.3.1.4
Group cooling deadband in tenths of degrees Fahrenheit. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsCoolDeadbandMetric 1.3.6.1.4.1.318.1.1.13.6.2.3.1.5
Group cooling deadband in tenths of degrees Celsius. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsFanSpeedPreference 1.3.6.1.4.1.318.1.1.13.6.2.3.1.6
The group preferred fan speed setting.
OBJECT-TYPE    
  INTEGER low(1), med-low(2), med(3), med-high(4), high(5)  

airIRG3GroupSetpointsSupplyAirSetpointUS 1.3.6.1.4.1.318.1.1.13.6.2.3.1.7
Group supply air setpoint in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsSupplyAirSetpointMetric 1.3.6.1.4.1.318.1.1.13.6.2.3.1.8
Group supply air setpoint in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupSetpointsAirFlowControl 1.3.6.1.4.1.318.1.1.13.6.2.3.1.9
The group air flow control.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRG3GroupSetpointsLightingOnTime 1.3.6.1.4.1.318.1.1.13.6.2.3.1.10
The group lighting on time in minutes.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigTable 1.3.6.1.4.1.318.1.1.13.6.2.4
Allows to access group configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3GroupConfigEntry

airIRG3GroupConfigEntry 1.3.6.1.4.1.318.1.1.13.6.2.4.1
The group config table entry.
OBJECT-TYPE    
  AirIRG3GroupConfigEntry  

airIRG3GroupConfigIndex 1.3.6.1.4.1.318.1.1.13.6.2.4.1.1
Index of group config table.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigNumberofCoolingUnits 1.3.6.1.4.1.318.1.1.13.6.2.4.1.2
The number of cooling units.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigConfigurationType 1.3.6.1.4.1.318.1.1.13.6.2.4.1.3
The group configuration type. The spot configuration type is not supported. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER racs(1), spot(2), in-row(3), hacs(4)  

airIRG3GroupConfigCapacityControlType 1.3.6.1.4.1.318.1.1.13.6.2.4.1.4
The group capacity control. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER discrete(1), proportional(2)  

airIRG3GroupConfigFanSpeedControl 1.3.6.1.4.1.318.1.1.13.6.2.4.1.5
The group fan speed control.
OBJECT-TYPE    
  INTEGER automatic(1), manual(2)  

airIRG3GroupConfigCoolGainP 1.3.6.1.4.1.318.1.1.13.6.2.4.1.6
The gain component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigCoolResetRateI 1.3.6.1.4.1.318.1.1.13.6.2.4.1.7
The integral component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigCoolDerivativeD 1.3.6.1.4.1.318.1.1.13.6.2.4.1.8
The derivative component of the PID in hundredths.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigCoolPIDReset 1.3.6.1.4.1.318.1.1.13.6.2.4.1.9
Will reset the PID coefficients back to the factory defaults. Readback is not supported, returns -1.
OBJECT-TYPE    
  INTEGER readBack(1), reset(2)  

airIRG3GroupConfigNumberofBackupUnits 1.3.6.1.4.1.318.1.1.13.6.2.4.1.10
The number of backup units.
OBJECT-TYPE    
  INTEGER  

airIRG3GroupConfigRuntimeBalancingEnable 1.3.6.1.4.1.318.1.1.13.6.2.4.1.11
Enable or disable runtime balancing feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRG3GroupConfigLoadAssistEnable 1.3.6.1.4.1.318.1.1.13.6.2.4.1.12
Enable or disable load assist feature.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRG3Alarms 1.3.6.1.4.1.318.1.1.13.6.3
OBJECT IDENTIFIER    

airIRG3AlarmsTableSize 1.3.6.1.4.1.318.1.1.13.6.3.1
The number of active alarms in the airIRG3AlarmsTable.
OBJECT-TYPE    
  INTEGER  

airIRG3AlarmsTable 1.3.6.1.4.1.318.1.1.13.6.3.2
Table of active alarms for the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3AlarmsEntry

airIRG3AlarmsEntry 1.3.6.1.4.1.318.1.1.13.6.3.2.1
Alarms specification
OBJECT-TYPE    
  AirIRG3AlarmsEntry  

airIRG3AlarmsIndex 1.3.6.1.4.1.318.1.1.13.6.3.2.1.1
Alarm index.
OBJECT-TYPE    
  INTEGER  

airIRG3AlarmsEventCode 1.3.6.1.4.1.318.1.1.13.6.3.2.1.2
Event Code for the alarm. Returns (-1) if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3AlarmsDescription 1.3.6.1.4.1.318.1.1.13.6.3.2.1.3
Description of the alarm. Returns (-1) if not supported.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

airIRG3RDU 1.3.6.1.4.1.318.1.1.13.6.4
OBJECT IDENTIFIER    

airIRG3RDUTableSize 1.3.6.1.4.1.318.1.1.13.6.4.1
The RDU table size.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusTable 1.3.6.1.4.1.318.1.1.13.6.4.2
Allows to access RDU status table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDUStatusEntry

airIRG3RDUStatusEntry 1.3.6.1.4.1.318.1.1.13.6.4.2.1
The RDU status table entry.
OBJECT-TYPE    
  AirIRG3RDUStatusEntry  

airIRG3RDUStatusDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.2.1.1
Index of RDU status table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUID 1.3.6.1.4.1.318.1.1.13.6.4.2.1.2
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
OBJECT-TYPE    
  DisplayString  

airIRG3RDUStatusOnReadyStandby 1.3.6.1.4.1.318.1.1.13.6.4.2.1.3
The RDU current status.
OBJECT-TYPE    
  INTEGER standby(1), ready(2), on(3)  

airIRG3RDUStatusOperatingMode 1.3.6.1.4.1.318.1.1.13.6.4.2.1.4
The RDU actual operating mode.
OBJECT-TYPE    
  INTEGER standby(1), ready(2), on(3), stop(4), maintenancemode(5)  

airIRG3RDUStatusLeadPump 1.3.6.1.4.1.318.1.1.13.6.4.2.1.5
The RDU lead pump.
OBJECT-TYPE    
  INTEGER pump1(1), pump2(2)  

airIRG3RDUStatusStartupDelay 1.3.6.1.4.1.318.1.1.13.6.4.2.1.6
The RDU start up delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPumpChangeOverInterval 1.3.6.1.4.1.318.1.1.13.6.4.2.1.7
The RDU pump change over interval in days.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusStopOnLeakDetect 1.3.6.1.4.1.318.1.1.13.6.4.2.1.8
The RDU status of stop on leak detect.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3RDUStatusPowerSource 1.3.6.1.4.1.318.1.1.13.6.4.2.1.9
The RDU power source status.
OBJECT-TYPE    
  INTEGER singleFeed(1), dualFeed(2)  

airIRG3RDUStatusTotalRDUOutputPower 1.3.6.1.4.1.318.1.1.13.6.4.2.1.10
The RDU output power in tenths of kilowatts (kW).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusInletWaterTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.11
The RDU inlet water temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusInletWaterTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.12
The RDU inlet water temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusOutletWaterTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.13
The RDU outlet water temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusOutletWaterTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.14
The RDU outlet water temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserSaturationTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.15
The RDU condenser saturation temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserSaturationTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.16
The RDU condenser saturation temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusDewPointTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.17
The RDU dew point temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusDewPointTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.18
The RDU dew point temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPumpOutletTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.19
The RDU pump outlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPumpOutletTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.20
The RDU pump outlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusSubcoolerOutletTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.21
The RDU sub cooler outlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusSubcoolerOutletTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.22
The RDU sub cooler outlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserOutletTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.23
The RDU condenser outlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserOutletTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.24
The RDU condenser outlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserInletTempUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.25
The RDU condenser inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserInletTempMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.26
The RDU condenser inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserOutletPressureUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.27
The RDU condenser outlet pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCondenserOutletPressureMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.28
The RDU condenser outlet pressure in kiloPascals (KPa).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump1HeadPressureUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.29
The RDU Pump 1 head pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump1HeadPressureMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.30
The RDU Pump 1 head pressure in kiloPascals (KPa).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump2HeadPressureUS 1.3.6.1.4.1.318.1.1.13.6.4.2.1.31
The RDU Pump 2 head pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump2HeadPressureMetric 1.3.6.1.4.1.318.1.1.13.6.4.2.1.32
The RDU Pump 2 head pressure in kiloPascals (KPa).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump1Speed 1.3.6.1.4.1.318.1.1.13.6.4.2.1.33
The RDU Pump 1 speed in revolutions per minute (RPM).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusPump2Speed 1.3.6.1.4.1.318.1.1.13.6.4.2.1.34
The RDU Pump 2 speed in revolutions per minute (RPM).
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusCWValvePosition 1.3.6.1.4.1.318.1.1.13.6.4.2.1.35
The RDU CW Valve position in % open
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusReceiverLiquidLevel 1.3.6.1.4.1.318.1.1.13.6.4.2.1.36
The RDU receiver liquid level in % Full
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusDCPowerSupply1Current 1.3.6.1.4.1.318.1.1.13.6.4.2.1.37
The RDU DC Power Supply 1 Current in Amps
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusDCPowerSupply2Current 1.3.6.1.4.1.318.1.1.13.6.4.2.1.38
The RDU DC Power Supply 2 Current in Amps
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusTotalDCPowerSupplyCurrent 1.3.6.1.4.1.318.1.1.13.6.4.2.1.39
The RDU Total DC Power Supply Current in Amps
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusInputState 1.3.6.1.4.1.318.1.1.13.6.4.2.1.40
The RDU Input state.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRG3RDUStatusOutputState 1.3.6.1.4.1.318.1.1.13.6.4.2.1.41
The RDU Output state
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRG3RDUStatusByPassValvePosition 1.3.6.1.4.1.318.1.1.13.6.4.2.1.42
The RDU By Pass Valve position in % open
OBJECT-TYPE    
  INTEGER  

airIRG3RDUStatusRefrigerantLeakDetector 1.3.6.1.4.1.318.1.1.13.6.4.2.1.43
The RDU refrigerant leak detector status.
OBJECT-TYPE    
  INTEGER suspended(1), calibrating(2), operating(3), disabled(4)  

airIRG3RDURunHoursTable 1.3.6.1.4.1.318.1.1.13.6.4.3
Allows to access RDU run hours table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDURunHoursEntry

airIRG3RDURunHoursEntry 1.3.6.1.4.1.318.1.1.13.6.4.3.1
The RDU run hours table entry.
OBJECT-TYPE    
  AirIRG3RDURunHoursEntry  

airIRG3RDURunHoursDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.3.1.1
Index of RDU run hours table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDURunHoursRDUID 1.3.6.1.4.1.318.1.1.13.6.4.3.1.2
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
OBJECT-TYPE    
  DisplayString  

airIRG3RDURunHoursPump1 1.3.6.1.4.1.318.1.1.13.6.4.3.1.3
The RDU run hours of Pump 1.
OBJECT-TYPE    
  INTEGER  

airIRG3RDURunHoursPump2 1.3.6.1.4.1.318.1.1.13.6.4.3.1.4
The RDU run hours of Pump 2.
OBJECT-TYPE    
  INTEGER  

airIRG3RDURunHoursPowerSupply1 1.3.6.1.4.1.318.1.1.13.6.4.3.1.5
The RDU run hours of power supply 1.
OBJECT-TYPE    
  INTEGER  

airIRG3RDURunHoursPowerSupply2 1.3.6.1.4.1.318.1.1.13.6.4.3.1.6
The RDU run hours of power supply 2.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUServiceIntervalsTable 1.3.6.1.4.1.318.1.1.13.6.4.4
Allows to access RDU service intervals table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDUServiceIntervalsEntry

airIRG3RDUServiceIntervalsEntry 1.3.6.1.4.1.318.1.1.13.6.4.4.1
The service interval table entry.
OBJECT-TYPE    
  AirIRG3RDUServiceIntervalsEntry  

airIRG3RDUServiceIntervalsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.4.1.1
Index of service interval table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUServiceIntervalsRDUID 1.3.6.1.4.1.318.1.1.13.6.4.4.1.2
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
OBJECT-TYPE    
  DisplayString  

airIRG3RDUServiceIntervalsAirFilterInterval 1.3.6.1.4.1.318.1.1.13.6.4.4.1.3
The RDU service interval for air filter in hours. Returns -1 if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUServiceIntervalsAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.6.4.4.1.4
The RDU service interval air filter alarm status. Returns -1 if not supported.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

airIRG3RDUThresholdsTable 1.3.6.1.4.1.318.1.1.13.6.4.5
Allows to access RDU thresholds table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDUThresholdsEntry

airIRG3RDUThresholdsEntry 1.3.6.1.4.1.318.1.1.13.6.4.5.1
The RDU thresholds table entry.
OBJECT-TYPE    
  AirIRG3RDUThresholdsEntry  

airIRG3RDUThresholdsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.5.1.1
Index of RDU thresholds table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUThresholdsRDUID 1.3.6.1.4.1.318.1.1.13.6.4.5.1.2
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
OBJECT-TYPE    
  DisplayString  

airIRG3RDUThresholdsEnteringFluidTempHighUS 1.3.6.1.4.1.318.1.1.13.6.4.5.1.3
The RDU threshold for entering fluid temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUThresholdsEnteringFluidTempHighMetric 1.3.6.1.4.1.318.1.1.13.6.4.5.1.4
The RDU threshold for entering fluid temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUSetpointsTable 1.3.6.1.4.1.318.1.1.13.6.4.6
Allows to access RDU set points table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDUSetpointsEntry

airIRG3RDUSetpointsEntry 1.3.6.1.4.1.318.1.1.13.6.4.6.1
The RDU set points table entry.
OBJECT-TYPE    
  AirIRG3RDUSetpointsEntry  

airIRG3RDUSetpointsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.6.1.1
Index of RDU set points table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUConfigTable 1.3.6.1.4.1.318.1.1.13.6.4.7
Allows to access RDU configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3RDUConfigEntry

airIRG3RDUConfigEntry 1.3.6.1.4.1.318.1.1.13.6.4.7.1
The RDU configuration table entry.
OBJECT-TYPE    
  AirIRG3RDUConfigEntry  

airIRG3RDUConfigDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.4.7.1.1
Index of RDU configuration table.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUConfigRDUID 1.3.6.1.4.1.318.1.1.13.6.4.7.1.2
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
OBJECT-TYPE    
  DisplayString  

airIRG3RDUConfigStopOnLeakDetect 1.3.6.1.4.1.318.1.1.13.6.4.7.1.3
The RDU stop on leak detect set.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3RDUConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.6.4.7.1.4
The RDU start up delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUConfigPumpChangeOverInterval 1.3.6.1.4.1.318.1.1.13.6.4.7.1.5
The RDU pump change over interval in days.
OBJECT-TYPE    
  INTEGER  

airIRG3RDUConfigPowerSource 1.3.6.1.4.1.318.1.1.13.6.4.7.1.6
The RDU power source.
OBJECT-TYPE    
  INTEGER singleFeed(1), dualFeed(2)  

airIRG3RDUConfigOutputSource 1.3.6.1.4.1.318.1.1.13.6.4.7.1.7
The RDU output source.
OBJECT-TYPE    
  INTEGER anyalarm(1), onlycriticalalarms(2)  

airIRG3RDUConfigInputNormalState 1.3.6.1.4.1.318.1.1.13.6.4.7.1.8
The RDU Input Normal State.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRG3RDUConfigOutputNormalState 1.3.6.1.4.1.318.1.1.13.6.4.7.1.9
The RDU Output Normal State.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

airIRG3RDUConfigByPassValveEnabled 1.3.6.1.4.1.318.1.1.13.6.4.7.1.10
The RDU By Pass Valve Enabled State.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3RDUConfigRefrigerantLeakDetectorEnabled 1.3.6.1.4.1.318.1.1.13.6.4.7.1.11
The RDU Refrigerant Leak Detector Enabled State.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3RDUConfigCalibrateRefrigerantLeakDetector 1.3.6.1.4.1.318.1.1.13.6.4.7.1.12
This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. The read returns -1. Only 'yes' is supported.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3RDUConfigOnReadyStandby 1.3.6.1.4.1.318.1.1.13.6.4.7.1.13
This parameter allows to configure RDU on/standby parameter. Ready is currently not supported. If unsupported returns -1.
OBJECT-TYPE    
  INTEGER standby(1), ready(2), on(3)  

airIRG3CM 1.3.6.1.4.1.318.1.1.13.6.5
OBJECT IDENTIFIER    

airIRG3CMTableSize 1.3.6.1.4.1.318.1.1.13.6.5.1
The cooling module table size.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusTable 1.3.6.1.4.1.318.1.1.13.6.5.2
Allows to access CM status table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMStatusEntry

airIRG3CMStatusEntry 1.3.6.1.4.1.318.1.1.13.6.5.2.1
The CM status table entry.
OBJECT-TYPE    
  AirIRG3CMStatusEntry  

airIRG3CMStatusDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.2.1.1
Index of CM status table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusCMID 1.3.6.1.4.1.318.1.1.13.6.5.2.1.2
The CM ID (RDU Number - Group Number - CM Unit Number).
OBJECT-TYPE    
  DisplayString  

airIRG3CMStatusOperatingMode 1.3.6.1.4.1.318.1.1.13.6.5.2.1.3
The current operating mode of the CM.
OBJECT-TYPE    
  INTEGER standBy(1), on(2), idle(3)  

airIRG3CMStatusUnitType 1.3.6.1.4.1.318.1.1.13.6.5.2.1.4
The current CM unit type.
OBJECT-TYPE    
  INTEGER unconfigured(1), oa(2), ra(3)  

airIRG3CMStatusRackInletTempUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.5
The CM rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusRackInletTempMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.6
The CM rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusReturnAirTempUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.7
The CM return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusReturnAirTempMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.8
The CM return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusLiquidTempUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.9
The CM liquid temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusLiquidTempMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.10
The CM liquid temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusVaporTempUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.11
The CM vapor temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusVaporTempMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.12
The CM vapor temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusEvaporatorTempUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.13
The CM saturation temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusEvaporatorTempMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.14
The CM saturation temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusLiquidInletPressureUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.15
The CM Liquid Inlet pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusLiquidInletPressureMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.16
The CM Liquid Inlet pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusVaporOutletPressureUS 1.3.6.1.4.1.318.1.1.13.6.5.2.1.17
The CM Vapor Outlet pressure in pounds per square inch (PSI).
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusVaporOutletPressureMetric 1.3.6.1.4.1.318.1.1.13.6.5.2.1.18
The CM Vapor Outlet pressure in kiloPascals (kPa).
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusExpansionValvePosition 1.3.6.1.4.1.318.1.1.13.6.5.2.1.19
The CM expansion valve position in % open
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusEPRValvePosition 1.3.6.1.4.1.318.1.1.13.6.5.2.1.20
The CM Evaporator Pressure Regulator Valve Position in % open
OBJECT-TYPE    
  INTEGER  

airIRG3CMStatusLocalDisplayOnOffEnabled 1.3.6.1.4.1.318.1.1.13.6.5.2.1.21
The status of the on/off control on the CM local display.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3CMStatusAverageFanSpeed 1.3.6.1.4.1.318.1.1.13.6.5.2.1.22
The CM Average Fan Speed.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursTable 1.3.6.1.4.1.318.1.1.13.6.5.3
Allows to access CM run hours table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMRunHoursEntry

airIRG3CMRunHoursEntry 1.3.6.1.4.1.318.1.1.13.6.5.3.1
The CM run hours table entry.
OBJECT-TYPE    
  AirIRG3CMRunHoursEntry  

airIRG3CMRunHoursDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.3.1.1
Index of CM run hours table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursCMID 1.3.6.1.4.1.318.1.1.13.6.5.3.1.2
The CM ID (RDU Number - Group Number - CM Unit Number).
OBJECT-TYPE    
  DisplayString  

airIRG3CMRunHoursFan1 1.3.6.1.4.1.318.1.1.13.6.5.3.1.3
The CM run hours for Fan1. Returns (-1) if not appilcable.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursFan2 1.3.6.1.4.1.318.1.1.13.6.5.3.1.4
The CM run hours for Fan2. Returns (-1) if not appilcable.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursFan3 1.3.6.1.4.1.318.1.1.13.6.5.3.1.5
The CM run hours for Fan3. Returns (-1) if not appilcable.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursFan4 1.3.6.1.4.1.318.1.1.13.6.5.3.1.6
The CM run hours for Fan4. Returns (-1) if not appilcable.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursFan5 1.3.6.1.4.1.318.1.1.13.6.5.3.1.7
The CM run hours for Fan5. Returns (-1) if not appilcable.
OBJECT-TYPE    
  INTEGER  

airIRG3CMRunHoursAirFilter 1.3.6.1.4.1.318.1.1.13.6.5.3.1.8
The CM run hours for air filter.
OBJECT-TYPE    
  INTEGER  

airIRG3CMServiceIntervalsTable 1.3.6.1.4.1.318.1.1.13.6.5.4
Allows to access CM service intervals table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMServiceIntervalsEntry

airIRG3CMServiceIntervalsEntry 1.3.6.1.4.1.318.1.1.13.6.5.4.1
The CM service interval table entry.
OBJECT-TYPE    
  AirIRG3CMServiceIntervalsEntry  

airIRG3CMServiceIntervalsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.4.1.1
Index of CM service intervals table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMServiceIntervalsCMID 1.3.6.1.4.1.318.1.1.13.6.5.4.1.2
The CM ID (RDU Number - Group Number - CM Unit Number).
OBJECT-TYPE    
  DisplayString  

airIRG3CMServiceIntervalsAirFilterInterval 1.3.6.1.4.1.318.1.1.13.6.5.4.1.3
The CM service interval for air filter in weeks. Supported only for RA. Returns -1 if not supported.
OBJECT-TYPE    
  INTEGER  

airIRG3CMServiceIntervalsAirFilterAlarm 1.3.6.1.4.1.318.1.1.13.6.5.4.1.4
The CM service interval air filter alarm status. Supported only for RA. Returns -1 if not supported.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

airIRG3CMThresholdsTable 1.3.6.1.4.1.318.1.1.13.6.5.5
Allows to access CM thresholds table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMThresholdsEntry

airIRG3CMThresholdsEntry 1.3.6.1.4.1.318.1.1.13.6.5.5.1
The CM thresholds table entry.
OBJECT-TYPE    
  AirIRG3CMThresholdsEntry  

airIRG3CMThresholdsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.5.1.1
Index for CM thresholds table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsCMID 1.3.6.1.4.1.318.1.1.13.6.5.5.1.2
The CM ID (RDU Number - Group Number - CM Unit Number).
OBJECT-TYPE    
  DisplayString  

airIRG3CMThresholdsRackInletTempHighUS 1.3.6.1.4.1.318.1.1.13.6.5.5.1.3
The CM high threshold for rack inlet temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsRackInletTempHighMetric 1.3.6.1.4.1.318.1.1.13.6.5.5.1.4
The CM high threshold for rack inlet temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsSupplyAirTempHighUS 1.3.6.1.4.1.318.1.1.13.6.5.5.1.5
The CM high threshold for supply air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsSupplyAirTempHighMetric 1.3.6.1.4.1.318.1.1.13.6.5.5.1.6
The CM high threshold for supply air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsReturnAirTempHighUS 1.3.6.1.4.1.318.1.1.13.6.5.5.1.7
The CM high threshold for return air temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

airIRG3CMThresholdsReturnAirTempHighMetric 1.3.6.1.4.1.318.1.1.13.6.5.5.1.8
The CM high threshold for return air temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

airIRG3CMSetpointsTable 1.3.6.1.4.1.318.1.1.13.6.5.6
Allows to access CM set points table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMSetpointsEntry

airIRG3CMSetpointsEntry 1.3.6.1.4.1.318.1.1.13.6.5.6.1
The CM set points table entry.
OBJECT-TYPE    
  AirIRG3CMSetpointsEntry  

airIRG3CMSetpointsDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.6.1.1
Index of CM set points table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMConfigTable 1.3.6.1.4.1.318.1.1.13.6.5.7
Allows to access CM configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    AirIRG3CMConfigEntry

airIRG3CMConfigEntry 1.3.6.1.4.1.318.1.1.13.6.5.7.1
The CM configuration table entry.
OBJECT-TYPE    
  AirIRG3CMConfigEntry  

airIRG3CMConfigDeviceIndex 1.3.6.1.4.1.318.1.1.13.6.5.7.1.1
Index of CM configuration table.
OBJECT-TYPE    
  INTEGER  

airIRG3CMConfigCMID 1.3.6.1.4.1.318.1.1.13.6.5.7.1.2
The CM ID (RDU Number - Group Number - CM Unit Number).
OBJECT-TYPE    
  DisplayString  

airIRG3CMConfigStopOnCoolFail 1.3.6.1.4.1.318.1.1.13.6.5.7.1.3
Enable/Disable Stop On cool fail. When enabled, stops the unit if it detects that it is blowing warm air into the cold aisle.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

airIRG3CMConfigStartupDelay 1.3.6.1.4.1.318.1.1.13.6.5.7.1.4
The CM start up delay in seconds.
OBJECT-TYPE    
  INTEGER  

airIRG3CMConfigRemoteOnStandby 1.3.6.1.4.1.318.1.1.13.6.5.7.1.5
The CM configuration for operating mode.
OBJECT-TYPE    
  INTEGER standBy(1), on(2)  

airIRG3CMConfigPowerSource 1.3.6.1.4.1.318.1.1.13.6.5.7.1.6
The CM power source.
OBJECT-TYPE    
  INTEGER singleFeed(1), dualFeed(2)  

rARU 1.3.6.1.4.1.318.1.1.14
OBJECT IDENTIFIER    

rARUIdent 1.3.6.1.4.1.318.1.1.14.1
OBJECT IDENTIFIER    

rARUIdentTable 1.3.6.1.4.1.318.1.1.14.1.1
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUIdentEntry

rARUIdentEntry 1.3.6.1.4.1.318.1.1.14.1.1.1
The device to query.
OBJECT-TYPE    
  RARUIdentEntry  

rARUIdentAruIndex 1.3.6.1.4.1.318.1.1.14.1.1.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUIdentName 1.3.6.1.4.1.318.1.1.14.1.1.1.2
A character string identifying the device.
OBJECT-TYPE    
  DisplayString  

rARUConfig 1.3.6.1.4.1.318.1.1.14.2
OBJECT IDENTIFIER    

rARUConfigTable 1.3.6.1.4.1.318.1.1.14.2.1
Allows for configuration of the individual ARU devices accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUConfigEntry

rARUConfigEntry 1.3.6.1.4.1.318.1.1.14.2.1.1
The ARUs to configure.
OBJECT-TYPE    
  RARUConfigEntry  

rARUConfigAruIndex 1.3.6.1.4.1.318.1.1.14.2.1.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUConfigAruName 1.3.6.1.4.1.318.1.1.14.2.1.1.2
The name of the ARU.
OBJECT-TYPE    
  DisplayString  

rARUConfigAruRemoteSetpoint 1.3.6.1.4.1.318.1.1.14.2.1.1.3
This OID defines the desired base airflow of the ARU, and sets the speed of the ARU fans when the temperature override is inactive. Values specified in cfm (cubic feet per minute) can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). Values (1) through (9) are for support of legacy (1st generation) ARUs. Writing these values to a 2nd generation ARU will result in the following: A value greater than (9) will be ignored by a 1st generation ARU. aruOff (1) - Ignored aru85F-29C (2) - 1200 cfm aru90F-32C (3) - 800 cfm aru95F-35C (4) - 500 cfm aru100F-38C (5) - 400 cfm aru7kW (6) - 1200 cfm aru5kW (7) - 800 cfm aru3kW (8) - 500 cfm aru2kW (9) - 400 cfm NOTE: -1 will be returned if the ARU is not communicating.
OBJECT-TYPE    
  INTEGER aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)  

rARUConfigAruTempOvrdEnableDisable 1.3.6.1.4.1.318.1.1.14.2.1.1.4
This OID is used to enable/disable the remote temperature override setting of the ARU. If this OID is set to 1, the remote setting for temperature override is disabled. If this OID is set to 2, the remote setting for temperature override is enabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

rARUConfigAruTempOvrdSetpoint 1.3.6.1.4.1.318.1.1.14.2.1.1.5
This OID is the Temperature Override setpoint of the ARU. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees using the units specified in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

rARUConfigAruMasterControl 1.3.6.1.4.1.318.1.1.14.2.1.1.6
This is the master on/off control for the ARU.
OBJECT-TYPE    
  INTEGER aruOn(1), aruOff(2)  

rARUStatus 1.3.6.1.4.1.318.1.1.14.3
OBJECT IDENTIFIER    

rARUStatusAruDeviceCount 1.3.6.1.4.1.318.1.1.14.3.1
The total number of ARUs accessible from this IP.
OBJECT-TYPE    
  INTEGER  

rARUStatusSysTempUnits 1.3.6.1.4.1.318.1.1.14.3.2
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

rARUStatusTable 1.3.6.1.4.1.318.1.1.14.3.3
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUStatusEntry

rARUStatusEntry 1.3.6.1.4.1.318.1.1.14.3.3.1
The ARUs to access.
OBJECT-TYPE    
  RARUStatusEntry  

rARUStatusAruIndex 1.3.6.1.4.1.318.1.1.14.3.3.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUStatusAruName 1.3.6.1.4.1.318.1.1.14.3.3.1.2
The name of the ARU.
OBJECT-TYPE    
  DisplayString  

rARUStatusAruRemoteSetpoint 1.3.6.1.4.1.318.1.1.14.3.3.1.3
This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See also the rARUConfigAruRemoteSetpoint OID. NOTE: -1 will be returned if the ARU is not communicating.
OBJECT-TYPE    
  INTEGER aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)  

rARUStatusAruManualSetpoint 1.3.6.1.4.1.318.1.1.14.3.3.1.4
Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will always return a value of aruRem (10). NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees or kW. If the manual setpoint is set to Remote, or if the ARU doesn't have a manual switch, this OID will return aruRem.
OBJECT-TYPE    
  INTEGER aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW(6), aru5kW(7), aru3kW(8), aru2kW(9), aruRem(10)  

rARUStatusAruTemp1 1.3.6.1.4.1.318.1.1.14.3.3.1.5
ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

rARUStatusAruTemp2 1.3.6.1.4.1.318.1.1.14.3.3.1.6
ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

rARUStatusAruTemp3 1.3.6.1.4.1.318.1.1.14.3.3.1.7
ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

rARUStatusAruTempOvrdEnableDisable 1.3.6.1.4.1.318.1.1.14.3.3.1.8
This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting for temperature override is disabled. If this OID is a 2, the remote setting for temperature override is enabled.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

rARUStatusAruTempOvrdSetpoint 1.3.6.1.4.1.318.1.1.14.3.3.1.9
ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
OBJECT-TYPE    
  INTEGER  

rARUStatusAruAlarmState 1.3.6.1.4.1.318.1.1.14.3.3.1.10
An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: Flag 1: Fan Fail 1 Flag 2: Fan Fail 2 Flag 3: Fan Fail 3 Flag 4: Smoke (if ARU is equipped with smoke detector) Flag 5: High Temp (Out of Thermal Control) Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) Flag 7: Fan Fail 4 (Gen 2 ARU only) Flag 8: Reserved
OBJECT-TYPE    
  DisplayString  

rARUStatusAruCommStatus 1.3.6.1.4.1.318.1.1.14.3.3.1.11
The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no device.
OBJECT-TYPE    
  INTEGER commsNeverDiscovered(1), commsEstablished(2), commsLost(3)  

rARUStatusAruTempOvrdStatus 1.3.6.1.4.1.318.1.1.14.3.3.1.12
Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUConfigAruTempOvrdSetpoint OID.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

rARUStatusAruMasterControl 1.3.6.1.4.1.318.1.1.14.3.3.1.13
This is the master on/off control for the ARU.
OBJECT-TYPE    
  INTEGER aruOn(1), aruOff(2)  

rARUStatusAruTotalAirflow 1.3.6.1.4.1.318.1.1.14.3.3.1.14
The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour).
OBJECT-TYPE    
  INTEGER  

rARUFanStatus 1.3.6.1.4.1.318.1.1.14.4
OBJECT IDENTIFIER    

rARUFanStatusTable 1.3.6.1.4.1.318.1.1.14.4.1
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUFanStatusEntry

rARUFanStatusEntry 1.3.6.1.4.1.318.1.1.14.4.1.1
The device to query.
OBJECT-TYPE    
  RARUFanStatusEntry  

rARUFanStatusAruIndex 1.3.6.1.4.1.318.1.1.14.4.1.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUFanStatusNominalFanSpeed 1.3.6.1.4.1.318.1.1.14.4.1.1.2
The nominal rotational speed (RPM) of the fans when they are operating at the 100% level.
OBJECT-TYPE    
  INTEGER  

rARUFanStatusSelectedFanLevel 1.3.6.1.4.1.318.1.1.14.4.1.1.3
The currently selected ARU speed level, specified in percent of full capacity.
OBJECT-TYPE    
  INTEGER  

rARUFanStatusReplacementThreshold 1.3.6.1.4.1.318.1.1.14.4.1.1.4
Threshold above which a run hour alarm will exist, indicating that it might be time to proactively replace a fan.
OBJECT-TYPE    
  INTEGER disabled(1), khr20(2), khr25(3), khr30(4), khr35(5), khr40(6), khr50(7)  

rARUFanStatusFanIndex 1.3.6.1.4.1.318.1.1.14.4.1.1.5
The index to an individual fan table entry.
OBJECT-TYPE    
  INTEGER  

rARUFanStatusFanOperatingStatus 1.3.6.1.4.1.318.1.1.14.4.1.1.6
The current operating state of the fan.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), onOk(3), onDegraded(4), offFailed(5)  

rARUFanStatusFanRpmSpeed 1.3.6.1.4.1.318.1.1.14.4.1.1.7
The current rotational speed of the fan, specified in rotations per minute (RPM).
OBJECT-TYPE    
  INTEGER  

rARUFanStatusFanFlowRate 1.3.6.1.4.1.318.1.1.14.4.1.1.8
The flow rate provided by the fan, based on its measured rotational speed. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour).
OBJECT-TYPE    
  INTEGER  

rARUFanStatusFanInServiceDate 1.3.6.1.4.1.318.1.1.14.4.1.1.9
The installation/replacement date of the fan.
OBJECT-TYPE    
  DisplayString  

rARUFanStatusFanRunhourCounter 1.3.6.1.4.1.318.1.1.14.4.1.1.10
The total time for which the fan has been running. Specified in 10ths of hours.
OBJECT-TYPE    
  INTEGER  

rARUFanStatusFanRunhourReset 1.3.6.1.4.1.318.1.1.14.4.1.1.11
Writing yes to this This OID will reset a fan's total run hour counter, which is shown in the rARUFanStatusFanRunhourCounter OID.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

rARUPower 1.3.6.1.4.1.318.1.1.14.5
OBJECT IDENTIFIER    

rARUPowerStatusTable 1.3.6.1.4.1.318.1.1.14.5.1
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUPowerStatusEntry

rARUPowerStatusEntry 1.3.6.1.4.1.318.1.1.14.5.1.1
The device to query.
OBJECT-TYPE    
  RARUPowerStatusEntry  

rARUPowerStatusAruIndex 1.3.6.1.4.1.318.1.1.14.5.1.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUPowerStatusPrimaryAcPresent 1.3.6.1.4.1.318.1.1.14.5.1.1.2
Indicates whether or not line voltage is present on AC input 1.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

rARUPowerStatusAuxiliaryAcPresent 1.3.6.1.4.1.318.1.1.14.5.1.1.3
Indicates whether or not line voltage is present on AC input 2.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

rARUPowerStatusRedundantAcConfig 1.3.6.1.4.1.318.1.1.14.5.1.1.4
Indicates whether or not a dual cord is in use. When this setting is set to dualCord (2), aruRedundantPowerLostAlarm traps will be generated when either primary or auxiliary input voltage is not present. When this setting is set to singleCord (1), aruRedundantPowerLostAlarm traps will not be generated.
OBJECT-TYPE    
  INTEGER singleCord(1), dualCord(2)  

rARUSensors 1.3.6.1.4.1.318.1.1.14.6
OBJECT IDENTIFIER    

rARUSensorsStatusTableSize 1.3.6.1.4.1.318.1.1.14.6.1
The number of entries in the rARUSensorsStatusTable.
OBJECT-TYPE    
  INTEGER  

rARUSensorsStatusTable 1.3.6.1.4.1.318.1.1.14.6.2
Allows for getting environmental sensor status information.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUSensorsStatusEntry

rARUSensorsStatusEntry 1.3.6.1.4.1.318.1.1.14.6.2.1
The unit to get data from.
OBJECT-TYPE    
  RARUSensorsStatusEntry  

rARUSensorsStatusAruIndex 1.3.6.1.4.1.318.1.1.14.6.2.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUSensorsStatusSensorNumber 1.3.6.1.4.1.318.1.1.14.6.2.1.2
The number of the sensor on the device.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTemperature 1.3.6.1.4.1.318.1.1.14.6.2.1.3
The sensor's current temperature reading. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsConfigTableSize 1.3.6.1.4.1.318.1.1.14.6.3
The number of entries in the rARUSensorsConfigTable.
OBJECT-TYPE    
  INTEGER  

rARUSensorsConfigTable 1.3.6.1.4.1.318.1.1.14.6.4
Allows for getting configuration information from environmental sensors attached to the device.
OBJECT-TYPE    
  SEQUENCE OF  
    RARUSensorsConfigEntry

rARUSensorsConfigEntry 1.3.6.1.4.1.318.1.1.14.6.4.1
The unit to get data from.
OBJECT-TYPE    
  RARUSensorsConfigEntry  

rARUSensorsConfigAruIndex 1.3.6.1.4.1.318.1.1.14.6.4.1.1
The index to the ARU entry.
OBJECT-TYPE    
  INTEGER  

rARUSensorsConfigSensorNumber 1.3.6.1.4.1.318.1.1.14.6.4.1.2
The number of the sensor on the device.
OBJECT-TYPE    
  INTEGER  

rARUSensorsName 1.3.6.1.4.1.318.1.1.14.6.4.1.3
A descriptive name for the sensor.
OBJECT-TYPE    
  DisplayString  

rARUSensorsLocation 1.3.6.1.4.1.318.1.1.14.6.4.1.4
The location of the sensor.
OBJECT-TYPE    
  DisplayString  

rARUSensorsTempMaxThresh 1.3.6.1.4.1.318.1.1.14.6.4.1.5
The temperature at which a maximum temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempHighThresh 1.3.6.1.4.1.318.1.1.14.6.4.1.6
The temperature at which a high temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempLowThresh 1.3.6.1.4.1.318.1.1.14.6.4.1.7
The temperature at which a low temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempMinThresh 1.3.6.1.4.1.318.1.1.14.6.4.1.8
The temperature at which a min temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempThreshHysteresis 1.3.6.1.4.1.318.1.1.14.6.4.1.9
The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempShortDecRateThreshValue 1.3.6.1.4.1.318.1.1.14.6.4.1.10
The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempShortDecRateThreshTime 1.3.6.1.4.1.318.1.1.14.6.4.1.11
The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempShortIncRateThreshValue 1.3.6.1.4.1.318.1.1.14.6.4.1.12
The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempShortIncRateThreshTime 1.3.6.1.4.1.318.1.1.14.6.4.1.13
The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempLongDecRateThreshValue 1.3.6.1.4.1.318.1.1.14.6.4.1.14
The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempLongDecRateThreshTime 1.3.6.1.4.1.318.1.1.14.6.4.1.15
The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempLongIncRateThreshValue 1.3.6.1.4.1.318.1.1.14.6.4.1.16
The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
OBJECT-TYPE    
  INTEGER  

rARUSensorsTempLongIncRateThreshTime 1.3.6.1.4.1.318.1.1.14.6.4.1.17
The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value.
OBJECT-TYPE    
  INTEGER  

xPDU 1.3.6.1.4.1.318.1.1.15
OBJECT IDENTIFIER    

xPDUIdent 1.3.6.1.4.1.318.1.1.15.1
OBJECT IDENTIFIER    

xPDUIdentProductName 1.3.6.1.4.1.318.1.1.15.1.1
The name of the PDU.
OBJECT-TYPE    
  DisplayString  

xPDUIdentHardwareRev 1.3.6.1.4.1.318.1.1.15.1.2
The hardware revision of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xPDUIdentFirmwareAppRev 1.3.6.1.4.1.318.1.1.15.1.3
An ID string identifying the application firmware revision of the PDU.
OBJECT-TYPE    
  DisplayString  

xPDUIdentFirmwareAppOSRev 1.3.6.1.4.1.318.1.1.15.1.4
An ID string identifying the application operating system firmware revision of the PDU.
OBJECT-TYPE    
  DisplayString  

xPDUIdentFirmwareControllerRev 1.3.6.1.4.1.318.1.1.15.1.5
An ID string identifying the PDU controller firmware revision.
OBJECT-TYPE    
  DisplayString  

xPDUIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.15.1.6
The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xPDUIdentModelNumber 1.3.6.1.4.1.318.1.1.15.1.7
A character string identifying the model number of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xPDUIdentSerialNumber 1.3.6.1.4.1.318.1.1.15.1.8
A character string identifying the serial number of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xPDUDevice 1.3.6.1.4.1.318.1.1.15.2
OBJECT IDENTIFIER    

xPDUDeviceNominalMainInputVoltage 1.3.6.1.4.1.318.1.1.15.2.1
The nominal main input voltage to the PDU. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service.
OBJECT-TYPE    
  INTEGER  

xPDUDeviceServiceType 1.3.6.1.4.1.318.1.1.15.2.2
The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye).
OBJECT-TYPE    
  INTEGER threeWire(1), fourWire(2)  

xPDUDeviceNominalOutputVoltage 1.3.6.1.4.1.318.1.1.15.2.3
The nominal line-to-neutral output voltage to the load measured in Volts.
OBJECT-TYPE    
  INTEGER  

xPDUDeviceMainInputBreakerRating 1.3.6.1.4.1.318.1.1.15.2.4
The rating of the main input breaker measured in Amps.
OBJECT-TYPE    
  INTEGER  

xPDUDevicePanelBreakerRating 1.3.6.1.4.1.318.1.1.15.2.5
The rating of the panel breaker measured in Amps.
OBJECT-TYPE    
  INTEGER  

xPDUDeviceTransformerPresent 1.3.6.1.4.1.318.1.1.15.2.6
Indicates whether or not a transformer is installed in the PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceLoadTieBreakerPresent 1.3.6.1.4.1.318.1.1.15.2.7
Indicates whether or not a load tie breaker is installed in the PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceLoadTestPortPresent 1.3.6.1.4.1.318.1.1.15.2.8
Indicates whether or not a load test port is installed in the PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceFusesPresent 1.3.6.1.4.1.318.1.1.15.2.9
Indicates whether or not the UPS feed from the PDU includes fuses.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceFansPresent 1.3.6.1.4.1.318.1.1.15.2.10
Indicates whether or not cooling fans are installed in the PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceBypassInputPresent 1.3.6.1.4.1.318.1.1.15.2.11
Indicates whether or not the PDU is equipped with a second feed for the UPS's bypass input.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceCrossTieOutputPresent 1.3.6.1.4.1.318.1.1.15.2.12
Indicates whether or not the PDU is equipped with a cross-tie output.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceEarthGroundMonitorPresent 1.3.6.1.4.1.318.1.1.15.2.13
Indicates whether or not the PDU can provide ground current measurements.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

xPDUDeviceInfraStruXureType 1.3.6.1.4.1.318.1.1.15.2.14
Indicates the configuration of this PDU system. Type-B PDU is in a distributed UPS system and has bypass capabilities. Type-C PDU receives power from a larger central UPS.
OBJECT-TYPE    
  INTEGER typeB(1), typeC(2)  

xPDUACMonitoringPoint 1.3.6.1.4.1.318.1.1.15.3
OBJECT IDENTIFIER    

xPDUMainInput 1.3.6.1.4.1.318.1.1.15.3.1
OBJECT IDENTIFIER    

xPDUMainInputOverVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.1.1
Threshold above which an input over voltage condition will be generated. Specified as percent deviation from nominal.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUMainInputUnderVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.1.2
Threshold below which an input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUMainInputVoltageTableSize 1.3.6.1.4.1.318.1.1.15.3.1.3
The number of Main input voltage entries.
OBJECT-TYPE    
  INTEGER  

xPDUMainInputVoltagePhaseTable 1.3.6.1.4.1.318.1.1.15.3.1.4
A list of input voltage table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUMainInputVoltageTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUMainInputVoltagePhaseEntry

xPDUMainInputVoltagePhaseEntry 1.3.6.1.4.1.318.1.1.15.3.1.4.1
An entry containing information applicable to a particular main input voltage phase.
OBJECT-TYPE    
  XPDUMainInputVoltagePhaseEntry  

xPDUMainInputVoltagePhaseIndex 1.3.6.1.4.1.318.1.1.15.3.1.4.1.1
Description of each input phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xPDUMainInputVoltageLtoL 1.3.6.1.4.1.318.1.1.15.3.1.4.1.2
Line-to-line PDU input voltage when an isolation transformer is present, or -1 if no transformer present in this PDU. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUMainInputVoltageLtoN 1.3.6.1.4.1.318.1.1.15.3.1.4.1.3
Line-to-neutral PDU input voltage when an isolation transformer is not present, or -1 if a transformer is present in this PDU. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUBypassInput 1.3.6.1.4.1.318.1.1.15.3.2
OBJECT IDENTIFIER    

xPDUBypassInputOverVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.2.1
Threshold above which a bypass input over voltage condition will be generated. Specified as percent deviation from nominal.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUBypassInputUnderVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.2.2
Threshold below which an bypass input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUBypassInputVoltagePhaseTableSize 1.3.6.1.4.1.318.1.1.15.3.2.3
The number of bypass input voltage entries.
OBJECT-TYPE    
  INTEGER  

xPDUBypassInputVoltagePhaseTable 1.3.6.1.4.1.318.1.1.15.3.2.4
A list of output table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUBypassInputVoltagePhaseTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUBypassInputVoltagePhaseEntry

xPDUBypassInputVoltagePhaseEntry 1.3.6.1.4.1.318.1.1.15.3.2.4.1
An entry containing information applicable to a particular bypass input voltage phase.
OBJECT-TYPE    
  XPDUBypassInputVoltagePhaseEntry  

xPDUBypassInputVoltagePhaseIndex 1.3.6.1.4.1.318.1.1.15.3.2.4.1.1
Index of each bypass input phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xPDUBypassInputVoltageLtoL 1.3.6.1.4.1.318.1.1.15.3.2.4.1.2
Line-to-line bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUBypassInputVoltageLtoN 1.3.6.1.4.1.318.1.1.15.3.2.4.1.3
Line-to-neutral bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUUPSInput 1.3.6.1.4.1.318.1.1.15.3.3
OBJECT IDENTIFIER    

xPDUUPSInputVoltagePhaseTableSize 1.3.6.1.4.1.318.1.1.15.3.3.1
The number of UPS input voltage entries.
OBJECT-TYPE    
  INTEGER  

xPDUUPSInputVoltagePhaseTable 1.3.6.1.4.1.318.1.1.15.3.3.2
A list of UPS input table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUUPSInputVoltagePhaseTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUUPSInputVoltagePhaseEntry

xPDUUPSInputVoltagePhaseEntry 1.3.6.1.4.1.318.1.1.15.3.3.2.1
An entry containing information applicable to a particular UPS input voltage phase.
OBJECT-TYPE    
  XPDUUPSInputVoltagePhaseEntry  

xPDUUPSInputVoltagePhaseIndex 1.3.6.1.4.1.318.1.1.15.3.3.2.1.1
Description of each UPS input phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xPDUUPSInputVoltageLtoNPresent 1.3.6.1.4.1.318.1.1.15.3.3.2.1.2
Indicates whether or not voltage is present at the UPS feed.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2), unknown(3)  

xPDUSystemOutput 1.3.6.1.4.1.318.1.1.15.3.4
OBJECT IDENTIFIER    

xPDUSystemOutputFrequency 1.3.6.1.4.1.318.1.1.15.3.4.1
The system output frequency in tenths of Hertz.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputNeutralCurrent 1.3.6.1.4.1.318.1.1.15.3.4.2
Shows the neutral current measured at the system output in tenths of Amps.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputTotalPower 1.3.6.1.4.1.318.1.1.15.3.4.3
Shows the total system output power in tenths of kW.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputTotalApparentPower 1.3.6.1.4.1.318.1.1.15.3.4.4
Shows the total system output power in tenths of kVA.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputTotalPowerFactor 1.3.6.1.4.1.318.1.1.15.3.4.5
Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00). Measured in hundredths.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputFrequencyTolerance 1.3.6.1.4.1.318.1.1.15.3.4.6
Shows the circuit panel output frequency tolerance in Hertz.
OBJECT-TYPE    
  INTEGER freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)  

xPDUSystemOutputMaxKWPower 1.3.6.1.4.1.318.1.1.15.3.4.7
Defines 100% load in kW. Purpose is to set to match UPS capabilities.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputOverVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.4.8
Threshold above which an output over voltage condition will be generated. Specified as percent deviation from nominal.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUSystemOutputUnderVoltThreshold 1.3.6.1.4.1.318.1.1.15.3.4.9
Threshold below which an output under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..30  

xPDUSystemOutputOverCurrentThreshold 1.3.6.1.4.1.318.1.1.15.3.4.10
Threshold above which an over current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUSystemOutputOverCurrentNeutralThreshold 1.3.6.1.4.1.318.1.1.15.3.4.11
Threshold above which an Over current neutral condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUSystemOutputUnderCurrentThreshold 1.3.6.1.4.1.318.1.1.15.3.4.12
Threshold below which an under current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUSystemOutputTableSize 1.3.6.1.4.1.318.1.1.15.3.4.13
The number of System Output phase entries.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputPhaseTable 1.3.6.1.4.1.318.1.1.15.3.4.14
A list of system output table entries. The number of entries is contained in the xPDUSystemOutputTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUSystemOutputPhaseEntry

xPDUSystemOutputPhaseEntry 1.3.6.1.4.1.318.1.1.15.3.4.14.1
An entry containing information applicable to a particular system output phase.
OBJECT-TYPE    
  XPDUSystemOutputPhaseEntry  

xPDUSystemOutputPhaseIndex 1.3.6.1.4.1.318.1.1.15.3.4.14.1.1
Description of each output phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xPDUSystemOutputVoltageLtoL 1.3.6.1.4.1.318.1.1.15.3.4.14.1.2
Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputVoltageLtoN 1.3.6.1.4.1.318.1.1.15.3.4.14.1.3
Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputPhaseCurrent 1.3.6.1.4.1.318.1.1.15.3.4.14.1.4
System load current per phase. Measured in tenths of Amps.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputPower 1.3.6.1.4.1.318.1.1.15.3.4.14.1.5
System output power per phase. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputApparentPower 1.3.6.1.4.1.318.1.1.15.3.4.14.1.6
System output power per phase. Measured in tenths of kVA.
OBJECT-TYPE    
  INTEGER  

xPDUSystemOutputPowerFactor 1.3.6.1.4.1.318.1.1.15.3.4.14.1.7
Indicates the Power Factor of the system output per phase. A value of 100 representing a unity Power Factor (1.00). Measured in hundredths.
OBJECT-TYPE    
  INTEGER  

xPDUGroundMonitorPoint 1.3.6.1.4.1.318.1.1.15.3.5
OBJECT IDENTIFIER    

xPDUGroundCurrent 1.3.6.1.4.1.318.1.1.15.3.5.1
Shows the current measured in the earth ground conductor. Measured in tenths of Amps, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xPDUGroundCurrentThreshold 1.3.6.1.4.1.318.1.1.15.3.5.2
Threshold above which a ground current over current condition will be generated. Specified in tenths of Amps.
OBJECT-TYPE    
  INTEGER 0..50  

xPDUCircuitBreakers 1.3.6.1.4.1.318.1.1.15.4
OBJECT IDENTIFIER    

xPDUSystemBreakers 1.3.6.1.4.1.318.1.1.15.4.1
OBJECT IDENTIFIER    

xPDUSystemBreakerTableSize 1.3.6.1.4.1.318.1.1.15.4.1.1
The number of system breaker entries.
OBJECT-TYPE    
  INTEGER  

xPDUSystemBreakerTable 1.3.6.1.4.1.318.1.1.15.4.1.2
A list of system breaker entries. The number of entries is contained in the xPDUSystemBreakerTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUSystemBreakerEntry

xPDUSystemBreakerEntry 1.3.6.1.4.1.318.1.1.15.4.1.2.1
An entry containing information applicable to a particular system breaker.
OBJECT-TYPE    
  XPDUSystemBreakerEntry  

xPDUSystemBreakerTableIndex 1.3.6.1.4.1.318.1.1.15.4.1.2.1.1
Index of system breaker entries in the table.
OBJECT-TYPE    
  INTEGER  

xPDUSystemBreakerDescription 1.3.6.1.4.1.318.1.1.15.4.1.2.1.2
A brief description of the system breakers.
OBJECT-TYPE    
  DisplayString SIZE(0..79)  

xPDUSystemBreakerPosition 1.3.6.1.4.1.318.1.1.15.4.1.2.1.3
Indicates whether this breaker is open(1) or closed(2).
OBJECT-TYPE    
  INTEGER open(1), closed(2), unknown(3)  

xPDUBranchBreakers 1.3.6.1.4.1.318.1.1.15.4.2
OBJECT IDENTIFIER    

xPDUNumOfBranchBreakers 1.3.6.1.4.1.318.1.1.15.4.2.1
The number of branch breakers (panel positions) in the Panel. returns 42 for a 1-panel or 84 for a 2-panel system.
OBJECT-TYPE    
  INTEGER  

xPDUBranchBreakerTableSize 1.3.6.1.4.1.318.1.1.15.4.2.2
The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID.
OBJECT-TYPE    
  INTEGER  

xPDUBranchBreakerTable 1.3.6.1.4.1.318.1.1.15.4.2.3
A list of branch breaker table entries. The number of entries is given by the value of xPDUBranchBreakerTableSize The number of entries is contained in the xPDUBranchBreakerTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUBranchBreakerEntry

xPDUBranchBreakerEntry 1.3.6.1.4.1.318.1.1.15.4.2.3.1
An entry containing information applicable to a particular branch breaker (panel position).
OBJECT-TYPE    
  XPDUBranchBreakerEntry  

xPDUBranchBreakerTableIndex 1.3.6.1.4.1.318.1.1.15.4.2.3.1.1
Index of branch breaker entries in the table.
OBJECT-TYPE    
  INTEGER  

xPDUBranchBreakerRating 1.3.6.1.4.1.318.1.1.15.4.2.3.1.2
Indicates current rating of this breaker. 0=Breaker is not present. 1=Earth leakage connection. 2=Neutral connection. A value greater than 2 indicates breaker current rating in Amps. A value above 60 Amp will signify a remote feed. The xPDUBranchBreakerRDPFeed OID will indicate which breakers are configured as a remote drop. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUBranchBreakerRDPFeed 1.3.6.1.4.1.318.1.1.15.4.2.3.1.3
Indicates that a breaker position is feeding a remote distribution panel.
OBJECT-TYPE    
  INTEGER remoteDistribution(1), noRemoteDistribution(2)  

xPDUBranchBreakerTieIndicator 1.3.6.1.4.1.318.1.1.15.4.2.3.1.4
Indicates whether or not the breaker in this position is logically associated with the breaker immediately below it. This setting is used grouping the breakers feeding a multi-pole branch circuit. Note: When setting an entry's branch breaker tie indicator to breakerTied, all the positions that are tied to this breaker will take on the rating and thresholds for this entry of the table.
OBJECT-TYPE    
  INTEGER breakerUnTied(1), breakerTied(2)  

xPDUBranchBreakerCurrent 1.3.6.1.4.1.318.1.1.15.4.2.3.1.5
Indicates the branch current in tenths of Amps or -1 when not available.
OBJECT-TYPE    
  INTEGER  

xPDUBranchBreakerOverCurrentThreshold 1.3.6.1.4.1.318.1.1.15.4.2.3.1.6
Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUBranchBreakerUnderCurrentThreshold 1.3.6.1.4.1.318.1.1.15.4.2.3.1.7
Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUBranchBreakerMaxCurrentThreshold 1.3.6.1.4.1.318.1.1.15.4.2.3.1.8
Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUBranchBreakerMinCurrentThreshold 1.3.6.1.4.1.318.1.1.15.4.2.3.1.9
Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
OBJECT-TYPE    
  INTEGER 0..100  

xPDUBranchBreakerName 1.3.6.1.4.1.318.1.1.15.4.2.3.1.10
The description of the purpose/use of the breaker.
OBJECT-TYPE    
  DisplayString  

xPDUBranchBreakerLocation 1.3.6.1.4.1.318.1.1.15.4.2.3.1.11
The description of the location of the breaker.
OBJECT-TYPE    
  DisplayString  

xPDUInputContacts 1.3.6.1.4.1.318.1.1.15.5
OBJECT IDENTIFIER    

xPDUInputContactNumContacts 1.3.6.1.4.1.318.1.1.15.5.1
The number of contacts supported by the PDU.
OBJECT-TYPE    
  INTEGER  

xPDUInputContactTableSize 1.3.6.1.4.1.318.1.1.15.5.2
The number of input contact entries.
OBJECT-TYPE    
  INTEGER  

xPDUInputContactTable 1.3.6.1.4.1.318.1.1.15.5.3
A list of contacts supported by the PDU. The number of entries is contained in the xPDUInputContactTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUInputContactEntry

xPDUInputContactEntry 1.3.6.1.4.1.318.1.1.15.5.3.1
A contact entry containing information for a given contact.
OBJECT-TYPE    
  XPDUInputContactEntry  

xPDUInputContactNumber 1.3.6.1.4.1.318.1.1.15.5.3.1.1
An index identifying the contact on the PDU.
OBJECT-TYPE    
  INTEGER  

xPDUInputContactName 1.3.6.1.4.1.318.1.1.15.5.3.1.2
The description of the purpose/use of the contact.
OBJECT-TYPE    
  DisplayString  

xPDUInputContactNormalState 1.3.6.1.4.1.318.1.1.15.5.3.1.3
The normal operating position of the contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xPDUInputContactCurrentState 1.3.6.1.4.1.318.1.1.15.5.3.1.4
This value indicates the current state of the contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2), unknown(3)  

xPDUOutputRelays 1.3.6.1.4.1.318.1.1.15.6
OBJECT IDENTIFIER    

xPDUOutputRelaysNumRelays 1.3.6.1.4.1.318.1.1.15.6.1
The number of output relays supported by the PDU.
OBJECT-TYPE    
  INTEGER  

xPDUOutputRelaysTableSize 1.3.6.1.4.1.318.1.1.15.6.2
The number of output relay entries.
OBJECT-TYPE    
  INTEGER  

xPDUOutputRelayTable 1.3.6.1.4.1.318.1.1.15.6.3
A list of output relays supported by the PDU. The number of entries is contained in the xPDUOutputRelayTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XPDUOutputRelayEntry

xPDUOutputRelayEntry 1.3.6.1.4.1.318.1.1.15.6.3.1
A output relay entry containing information for a given contact.
OBJECT-TYPE    
  XPDUOutputRelayEntry  

xPDUOutputRelayNumber 1.3.6.1.4.1.318.1.1.15.6.3.1.1
An index identifying the output relay on the PDU.
OBJECT-TYPE    
  INTEGER  

xPDUOutputRelayName 1.3.6.1.4.1.318.1.1.15.6.3.1.2
The description of the purpose/use of the output relay.
OBJECT-TYPE    
  DisplayString  

xPDUOutputRelayNormalState 1.3.6.1.4.1.318.1.1.15.6.3.1.3
The normal operating position of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xPDUOutputRelayCurrentState 1.3.6.1.4.1.318.1.1.15.6.3.1.4
This value indicates the current state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2), unknown(3)  

xPDUMiscGroup 1.3.6.1.4.1.318.1.1.15.7
OBJECT IDENTIFIER    

xPDUEPOMode 1.3.6.1.4.1.318.1.1.15.7.1
Indicates whether the EPO System is armed(1) or disarmed(2).
OBJECT-TYPE    
  INTEGER armed(1), disarmed(2), unknown(3)  

xPDUTransformTempStatus 1.3.6.1.4.1.318.1.1.15.7.2
Indicates if the PDU's isolation transformer is over temperature.
OBJECT-TYPE    
  INTEGER normal(1), overtemp(2), noTransformerPresent(3), unknown(4)  

xPDUCoolingFanStatus 1.3.6.1.4.1.318.1.1.15.7.3
Indicates if one or more of the PDU's cooling fans have failed.
OBJECT-TYPE    
  INTEGER normal(1), failed(2), noCoolingFansPresent(3), unknown(4)  

battMan 1.3.6.1.4.1.318.1.1.16
OBJECT IDENTIFIER    

battManIdent 1.3.6.1.4.1.318.1.1.16.1
OBJECT IDENTIFIER    

battManIdentProductName 1.3.6.1.4.1.318.1.1.16.1.1
The name of the battery manager.
OBJECT-TYPE    
  DisplayString  

battManIdentHardwareRev 1.3.6.1.4.1.318.1.1.16.1.2
The battery manager network interface hardware revision. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

battManIdentFirmwareRev 1.3.6.1.4.1.318.1.1.16.1.3
The battery manager network interface firmware revision. This value is set at the factory and can change with firmware update.
OBJECT-TYPE    
  DisplayString  

battManIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.16.1.4
The date the battery manager was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

battManIdentModelNumber 1.3.6.1.4.1.318.1.1.16.1.5
The battery manager model number character string. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

battManIdentSerialNumber 1.3.6.1.4.1.318.1.1.16.1.6
The battery manager serial number character string. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

battManSystemCalib 1.3.6.1.4.1.318.1.1.16.2
OBJECT IDENTIFIER    

battManOhmicValueCorrectionFactor 1.3.6.1.4.1.318.1.1.16.2.1
The system ohmic value correction factor in percent.
OBJECT-TYPE    
  INTEGER  

battManUnitCalib 1.3.6.1.4.1.318.1.1.16.3
OBJECT IDENTIFIER    

battManUnitCalibTableSize 1.3.6.1.4.1.318.1.1.16.3.1
The number of entries in the battManUnitCalibTable.
OBJECT-TYPE    
  INTEGER  

battManUnitCalibTable 1.3.6.1.4.1.318.1.1.16.3.2
Allows for getting calibration information from each unit in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManUnitCalibEntry

battManUnitCalibEntry 1.3.6.1.4.1.318.1.1.16.3.2.1
The unit to get data from.
OBJECT-TYPE    
  BattManUnitCalibEntry  

battManUnitCalibIndex 1.3.6.1.4.1.318.1.1.16.3.2.1.1
Index of unit calibration entries in the table.
OBJECT-TYPE    
  INTEGER  

battManUnitSerialNumber 1.3.6.1.4.1.318.1.1.16.3.2.1.2
The serial number of the unit.
OBJECT-TYPE    
  DisplayString  

battManBatteryVoltageZeroCalib 1.3.6.1.4.1.318.1.1.16.3.2.1.3
The unit battery voltage zero calibration in millivolts.
OBJECT-TYPE    
  INTEGER  

battManBatteryVoltageSpanCalib 1.3.6.1.4.1.318.1.1.16.3.2.1.4
The unit battery voltage span calibration in percent.
OBJECT-TYPE    
  INTEGER  

battManStringCalib 1.3.6.1.4.1.318.1.1.16.4
OBJECT IDENTIFIER    

battManStringCalibTableSize 1.3.6.1.4.1.318.1.1.16.4.1
The number of entries in the battManStringCalibTable.
OBJECT-TYPE    
  INTEGER  

battManStringCalibTable 1.3.6.1.4.1.318.1.1.16.4.2
Allows for getting calibration information from each string in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManStringCalibEntry

battManStringCalibEntry 1.3.6.1.4.1.318.1.1.16.4.2.1
The string to get data from.
OBJECT-TYPE    
  BattManStringCalibEntry  

battManStringCalibIndex 1.3.6.1.4.1.318.1.1.16.4.2.1.1
Index of string calibration entries in the table.
OBJECT-TYPE    
  INTEGER  

battManDCCurrentZeroCalib 1.3.6.1.4.1.318.1.1.16.4.2.1.2
The string DC current zero calibration in tenths of amps.
OBJECT-TYPE    
  INTEGER  

battManACCurrentZeroCalib 1.3.6.1.4.1.318.1.1.16.4.2.1.3
The string AC current zero calibration in tenths of amps.
OBJECT-TYPE    
  INTEGER  

battManProbeRange 1.3.6.1.4.1.318.1.1.16.4.2.1.4
The string probe range in amps.
OBJECT-TYPE    
  INTEGER amps1000(1), amps500(2), amps100(3), amps200(4), amps2000(5)  

battManBatteryCalib 1.3.6.1.4.1.318.1.1.16.5
OBJECT IDENTIFIER    

battManString1BatteryCalibTableSize 1.3.6.1.4.1.318.1.1.16.5.1
The number of entries in the battManString1BatteryCalibTable.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryCalibTable 1.3.6.1.4.1.318.1.1.16.5.2
Allows for getting calibration information from each battery in String 1.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString1BatteryCalibEntry

battManString1BatteryCalibEntry 1.3.6.1.4.1.318.1.1.16.5.2.1
The string to get data from.
OBJECT-TYPE    
  BattManString1BatteryCalibEntry  

battManString1BatteryCalibIndex 1.3.6.1.4.1.318.1.1.16.5.2.1.1
Index of battery calibration entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryInterTierOhmicValue 1.3.6.1.4.1.318.1.1.16.5.2.1.2
The battery inter-tier ohmic value in ohms. This corresponds to the ohmic value for the positive terminal of the battery.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryCalibTableSize 1.3.6.1.4.1.318.1.1.16.5.3
The number of entries in the battManString2BatteryCalibTable.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryCalibTable 1.3.6.1.4.1.318.1.1.16.5.4
Allows for getting calibration information from each battery in String 2.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString2BatteryCalibEntry

battManString2BatteryCalibEntry 1.3.6.1.4.1.318.1.1.16.5.4.1
The string to get data from.
OBJECT-TYPE    
  BattManString2BatteryCalibEntry  

battManString2BatteryCalibIndex 1.3.6.1.4.1.318.1.1.16.5.4.1.1
Index of battery calibration entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryInterTierOhmicValue 1.3.6.1.4.1.318.1.1.16.5.4.1.2
The battery inter-tier ohmic value in ohms.
OBJECT-TYPE    
  INTEGER  

battManConfig 1.3.6.1.4.1.318.1.1.16.6
OBJECT IDENTIFIER    

battManConfigApplication 1.3.6.1.4.1.318.1.1.16.6.1
This OID has been deprecated.
OBJECT-TYPE    
  INTEGER silcon(1), other(2)  

battManConfigBatteryChemistry 1.3.6.1.4.1.318.1.1.16.6.2
The battery chemistry of the monitored batteries: LeadAcid(1) Lead Acid or Nickel-Cadmium(2) Nickel-Cadmium.
OBJECT-TYPE    
  INTEGER leadAcid(1), nickel-Cadmium(2)  

battManConfigBatteryAHCapacity 1.3.6.1.4.1.318.1.1.16.6.3
The amp hour capacity of the monitored batteries 5-2000 AH.
OBJECT-TYPE    
  INTEGER  

battManConfigNumberofStrings 1.3.6.1.4.1.318.1.1.16.6.4
The number of strings in the battery manager system.
OBJECT-TYPE    
  INTEGER  

battManConfigBatteriesperString 1.3.6.1.4.1.318.1.1.16.6.5
The number of batteries per string.
OBJECT-TYPE    
  INTEGER  

battManConfigCellsperBattery 1.3.6.1.4.1.318.1.1.16.6.6
The number of cells per battery (1 - 6 for lead-acid, 1 - 2 for NiCd.
OBJECT-TYPE    
  INTEGER  

battManConfigMinCellVoltage 1.3.6.1.4.1.318.1.1.16.6.7
The minimum battery cell voltage alarm limit in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxCellVoltage 1.3.6.1.4.1.318.1.1.16.6.8
The maximum battery cell voltage alarm limit in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxPilotTempF 1.3.6.1.4.1.318.1.1.16.6.9
The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxPilotTempC 1.3.6.1.4.1.318.1.1.16.6.10
The maximum pilot battery temperature alarm limit in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxAmbientTempF 1.3.6.1.4.1.318.1.1.16.6.11
The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxAmbientTempC 1.3.6.1.4.1.318.1.1.16.6.12
The maximum ambient temperature alarm limit in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

battManConfigMinAmbientTempF 1.3.6.1.4.1.318.1.1.16.6.13
The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

battManConfigMinAmbientTempC 1.3.6.1.4.1.318.1.1.16.6.14
The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxRippleCurrent 1.3.6.1.4.1.318.1.1.16.6.15
The maximum ripple current alarm limit for the monitored battery strings in percent of AH capacity.
OBJECT-TYPE    
  INTEGER  

battManConfigMaxCurrentAcceptanceDeviation 1.3.6.1.4.1.318.1.1.16.6.16
The maximum current acceptance deviation alarm limit in percent.
OBJECT-TYPE    
  INTEGER  

battManConfigMonitorWireLength 1.3.6.1.4.1.318.1.1.16.6.17
The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet.
OBJECT-TYPE    
  INTEGER fiftyFeetOrLess(1), moreThanFiftyFeet(2)  

battManConfigDischargeVoltageAlarmLevel 1.3.6.1.4.1.318.1.1.16.6.18
The discharge voltage alarm level in percent.
OBJECT-TYPE    
  INTEGER  

battManConfigAutoAnnunciatorReset 1.3.6.1.4.1.318.1.1.16.6.19
The annunciator output signal reset method: disabled(1) means the annunciator signal output will be reset when the reset button is pressed. enabled(2) means the annunciator will stop signaling when all alarm conditions clear.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

battManConfigSuspendCellVoltage 1.3.6.1.4.1.318.1.1.16.6.20
This is used along with the number of cells per battery and the number of batteries per string to determine if a battery string has violated the low voltage limit. If so, the Battery Management System will enter suspend mode. Measured in millivolts DC
OBJECT-TYPE    
  INTEGER  

battManConfigOhmicTestWaitTime 1.3.6.1.4.1.318.1.1.16.6.21
The amount of time in seconds after a discharge event before data will be collected for the ohmic value calculation.
OBJECT-TYPE    
  INTEGER  

battManConfigNumberOfBoosts 1.3.6.1.4.1.318.1.1.16.6.22
The number of consecutive times the Battery Management System applies a charge to each battery during a boost cycle. Batteries with a Rated Battery AH Capacity less than or equal to 120 AH will always have a value of one for Number of Boosts.
OBJECT-TYPE    
  INTEGER  

battManAlarm 1.3.6.1.4.1.318.1.1.16.7
OBJECT IDENTIFIER    

battManAlarmManagementController 1.3.6.1.4.1.318.1.1.16.7.1
The Management Controller Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManAlarmBatteries 1.3.6.1.4.1.318.1.1.16.7.2
The Batteries Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManAlarmCharger 1.3.6.1.4.1.318.1.1.16.7.3
The Charger Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManAlarmEnvironment 1.3.6.1.4.1.318.1.1.16.7.4
The Environment Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemStatus 1.3.6.1.4.1.318.1.1.16.8
OBJECT IDENTIFIER    

battManSystemAmbientTempC 1.3.6.1.4.1.318.1.1.16.8.1
The system ambient temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

battManSystemAmbientTempF 1.3.6.1.4.1.318.1.1.16.8.2
The system ambient temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

battManSystemPilotTempC 1.3.6.1.4.1.318.1.1.16.8.3
The system pilot temperature in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

battManSystemPilotTempF 1.3.6.1.4.1.318.1.1.16.8.4
The system pilot temperature in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

battManSystemAmbientHighTempAlarm 1.3.6.1.4.1.318.1.1.16.8.5
When set to alarm(2), indicates that the system has a high temperature alarm.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemAmbientLowTempAlarm 1.3.6.1.4.1.318.1.1.16.8.6
When set to alarm(2), indicates that the system has a low temperature alarm.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemPilotBatteryHighTempAlarm 1.3.6.1.4.1.318.1.1.16.8.7
When set to alarm(2), indicates that the system has a pilot battery high temperature alarm.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemPilotProbeDisconnected 1.3.6.1.4.1.318.1.1.16.8.8
When set to alarm(2), indicates that the system pilot probe is disconnected.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemAmbientProbeDisconnected 1.3.6.1.4.1.318.1.1.16.8.9
When set to alarm(2), indicates that the system ambient probe is disconnected.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemConfigurationInvalid 1.3.6.1.4.1.318.1.1.16.8.10
When set to alarm(2), indicates that the system is not configured correctly.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManSystemSuspendVoltage 1.3.6.1.4.1.318.1.1.16.8.11
When set to alarm(2), indicates that the system has suspended voltage scans.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringStatus 1.3.6.1.4.1.318.1.1.16.9
OBJECT IDENTIFIER    

battManStringTableSize 1.3.6.1.4.1.318.1.1.16.9.1
The number of entries in the battManStringTable.
OBJECT-TYPE    
  INTEGER  

battManStringTable 1.3.6.1.4.1.318.1.1.16.9.2
Allows for getting information from each string in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManStringEntry

battManStringEntry 1.3.6.1.4.1.318.1.1.16.9.2.1
The string to get data from.
OBJECT-TYPE    
  BattManStringEntry  

battManStringIndex 1.3.6.1.4.1.318.1.1.16.9.2.1.1
Index of string entries in the table.
OBJECT-TYPE    
  INTEGER  

battManStringCurrent 1.3.6.1.4.1.318.1.1.16.9.2.1.2
The string current in tenths of amps.
OBJECT-TYPE    
  INTEGER  

battManStringRippleCurrent 1.3.6.1.4.1.318.1.1.16.9.2.1.3
The string ripple current in tenths of amps.
OBJECT-TYPE    
  INTEGER  

battManStringChargerHighVoltageAlarm 1.3.6.1.4.1.318.1.1.16.9.2.1.4
When set to alarm(2), indicates that the string charger has a high voltage alarm.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringChargerLowVoltageAlarm 1.3.6.1.4.1.318.1.1.16.9.2.1.5
When set to alarm(2), indicates that the string charger has a low voltage alarm.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringCurrentProbeDisconnected 1.3.6.1.4.1.318.1.1.16.9.2.1.6
When set to alarm(2), indicates that the string charger probe is disconnected.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringOnBattery 1.3.6.1.4.1.318.1.1.16.9.2.1.7
When set to alarm(2), indicates that the string is in the on-battery state.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringHighRippleCurrent 1.3.6.1.4.1.318.1.1.16.9.2.1.8
When set to alarm(2), indicates that the string has a high ripple current.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManStringVoltage 1.3.6.1.4.1.318.1.1.16.9.2.1.9
The sum of the voltages for all of the batteries on a string in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManStringDischargeLess5Seconds 1.3.6.1.4.1.318.1.1.16.9.2.1.10
The number of recorded discharges lasting less than 5 seconds.
OBJECT-TYPE    
  INTEGER  

battManStringDischarge5to10Seconds 1.3.6.1.4.1.318.1.1.16.9.2.1.11
The number of recorded discharges lasting between 5 and 10 seconds.
OBJECT-TYPE    
  INTEGER  

battManStringDischarge10to60Seconds 1.3.6.1.4.1.318.1.1.16.9.2.1.12
The number of recorded discharges lasting between 10 and 60 seconds.
OBJECT-TYPE    
  INTEGER  

battManStringDischargeMore60Seconds 1.3.6.1.4.1.318.1.1.16.9.2.1.13
The number of recorded discharges lasting more than 60 seconds (1 minute).
OBJECT-TYPE    
  INTEGER  

battManBatteryStatus 1.3.6.1.4.1.318.1.1.16.10
OBJECT IDENTIFIER    

battManString1BatteryTableSize 1.3.6.1.4.1.318.1.1.16.10.1
The number of entries in the battManString1BatteryTable.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryTable 1.3.6.1.4.1.318.1.1.16.10.2
Allows for getting information from each string in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString1BatteryEntry

battManString1BatteryEntry 1.3.6.1.4.1.318.1.1.16.10.2.1
The string to get data from.
OBJECT-TYPE    
  BattManString1BatteryEntry  

battManString1BatteryIndex 1.3.6.1.4.1.318.1.1.16.10.2.1.1
Index of string entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryVoltage 1.3.6.1.4.1.318.1.1.16.10.2.1.2
The battery voltage in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryLowestVoltage 1.3.6.1.4.1.318.1.1.16.10.2.1.3
The lowest battery discharge voltage during the last power event in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManString1BatteryCellShorted 1.3.6.1.4.1.318.1.1.16.10.2.1.4
When set to alarm(2), indicates that a battery cell is shorted.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryOpenFuseOrConnection 1.3.6.1.4.1.318.1.1.16.10.2.1.5
When set to alarm(2), indicates that a fuse or connection is open.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryLowCapacity 1.3.6.1.4.1.318.1.1.16.10.2.1.6
When set to alarm(2), indicates a battery has low capacity.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryHighOhmicValue 1.3.6.1.4.1.318.1.1.16.10.2.1.7
When set to alarm(2), indicates a battery has a high ohmic value.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryThermalRunaway 1.3.6.1.4.1.318.1.1.16.10.2.1.8
When set to alarm(2), indicates a battery has a thermal runaway condition.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryDryout 1.3.6.1.4.1.318.1.1.16.10.2.1.9
When set to alarm(2), indicates a battery has a dryout condition.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryUserHighVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.2.1.10
When set to alarm(2), indicates a battery has violated the user level high voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryUserLowVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.2.1.11
When set to alarm(2), indicates a battery has violated the user level low voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryChemHighVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.2.1.12
When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryChemLowVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.2.1.13
When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString1BatteryOpenCell 1.3.6.1.4.1.318.1.1.16.10.2.1.14
When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryTableSize 1.3.6.1.4.1.318.1.1.16.10.3
The number of entries in the battManString2BatteryTable.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryTable 1.3.6.1.4.1.318.1.1.16.10.4
Allows for getting information from each string in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString2BatteryEntry

battManString2BatteryEntry 1.3.6.1.4.1.318.1.1.16.10.4.1
The string to get data from.
OBJECT-TYPE    
  BattManString2BatteryEntry  

battManString2BatteryIndex 1.3.6.1.4.1.318.1.1.16.10.4.1.1
Index of string entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryVoltage 1.3.6.1.4.1.318.1.1.16.10.4.1.2
The battery voltage in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryLowestVoltage 1.3.6.1.4.1.318.1.1.16.10.4.1.3
The lowest battery discharge voltage during the last power event in millivolts DC.
OBJECT-TYPE    
  INTEGER  

battManString2BatteryCellShorted 1.3.6.1.4.1.318.1.1.16.10.4.1.4
When set to alarm(2), indicates that a battery cell is shorted.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryOpenFuseOrConnection 1.3.6.1.4.1.318.1.1.16.10.4.1.5
When set to alarm(2), indicates that a fuse or connection is open.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryLowCapacity 1.3.6.1.4.1.318.1.1.16.10.4.1.6
When set to alarm(2), indicates a battery has low capacity.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryHighOhmicValue 1.3.6.1.4.1.318.1.1.16.10.4.1.7
When set to alarm(2), indicates a battery has a high ohmic value.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryThermalRunaway 1.3.6.1.4.1.318.1.1.16.10.4.1.8
When set to alarm(2), indicates a battery has a thermal runaway condition.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryDryout 1.3.6.1.4.1.318.1.1.16.10.4.1.9
When set to alarm(2), indicates a battery has a dryout condition.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryUserHighVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.4.1.10
When set to alarm(2), indicates a battery has violated the user level high voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryUserLowVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.4.1.11
When set to alarm(2), indicates a battery has violated the user level low voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryChemHighVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.4.1.12
When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryChemLowVoltageAlarm 1.3.6.1.4.1.318.1.1.16.10.4.1.13
When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManString2BatteryOpenCell 1.3.6.1.4.1.318.1.1.16.10.4.1.14
When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManInputContactStatus 1.3.6.1.4.1.318.1.1.16.11
OBJECT IDENTIFIER    

battManInputContactTableSize 1.3.6.1.4.1.318.1.1.16.11.1
The number of entries in the battManInputContactTable.
OBJECT-TYPE    
  INTEGER  

battManInputContactTable 1.3.6.1.4.1.318.1.1.16.11.2
Allows for getting information from each contact in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManInputContactEntry

battManInputContactEntry 1.3.6.1.4.1.318.1.1.16.11.2.1
The contact to get data from.
OBJECT-TYPE    
  BattManInputContactEntry  

battManInputContactIndex 1.3.6.1.4.1.318.1.1.16.11.2.1.1
Index of contact entries in the table.
OBJECT-TYPE    
  INTEGER  

battManInputContactName 1.3.6.1.4.1.318.1.1.16.11.2.1.2
The name of the input contact.
OBJECT-TYPE    
  DisplayString  

battManInputContactAlarmState 1.3.6.1.4.1.318.1.1.16.11.2.1.3
When set to alarm(2), indicates that the alarm condition is active for this contact.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManInputContactState 1.3.6.1.4.1.318.1.1.16.11.2.1.4
When set to open(1), the input contact is in the open state. When set to closed(2), the input contact is in the closed state.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

battManInputContactNormalState 1.3.6.1.4.1.318.1.1.16.11.2.1.5
When set to open(1), the input contact is normally open. When set to closed(2), the input contact is normally closed.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

battManInputContactAlarmDelay 1.3.6.1.4.1.318.1.1.16.11.2.1.6
The input contact alarm delay time in seconds.
OBJECT-TYPE    
  INTEGER  

battManControl 1.3.6.1.4.1.318.1.1.16.12
OBJECT IDENTIFIER    

battManRemoteAnnunciatorReset 1.3.6.1.4.1.318.1.1.16.12.1
Setting this OID to reset(2) will reset the user interface annunciator. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

battManResetChargeCurrentDeviationBenchmark 1.3.6.1.4.1.318.1.1.16.12.2
Setting this OID to reset(2) will reset the charge current deviation benchmark. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

battManResetLowestDischargeVoltages 1.3.6.1.4.1.318.1.1.16.12.3
Setting this OID to reset(2) will reset the lowest discharge voltages. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

battManResetDischargeCounters 1.3.6.1.4.1.318.1.1.16.12.4
Setting this OID to reset(2) will reset all discharge event counters. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

battManTestResults 1.3.6.1.4.1.318.1.1.16.13
OBJECT IDENTIFIER    

battManString1OhmicValueLastDischargeInfo 1.3.6.1.4.1.318.1.1.16.13.1
Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded.
OBJECT-TYPE    
  DisplayString  

battManString1OhmicValueTableSize 1.3.6.1.4.1.318.1.1.16.13.2
The number of entries in the battManString1OhmicValueTable.
OBJECT-TYPE    
  INTEGER  

battManString1OhmicValueTable 1.3.6.1.4.1.318.1.1.16.13.3
Allows for getting ohmic value information from each battery in String 1.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString1OhmicValueEntry

battManString1OhmicValueEntry 1.3.6.1.4.1.318.1.1.16.13.3.1
The string to get data from.
OBJECT-TYPE    
  BattManString1OhmicValueEntry  

battManString1OhmicValueIndex 1.3.6.1.4.1.318.1.1.16.13.3.1.1
The battery number.
OBJECT-TYPE    
  INTEGER  

battManString1OhmicValueData 1.3.6.1.4.1.318.1.1.16.13.3.1.2
The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors.
OBJECT-TYPE    
  INTEGER  

battManString1ResponseTestChangeTableSize 1.3.6.1.4.1.318.1.1.16.13.4
The number of entries in the battManString1ResponseTestChangeTable.
OBJECT-TYPE    
  INTEGER  

battManString1ResponseTestChangeTable 1.3.6.1.4.1.318.1.1.16.13.5
Allows for getting response test change information from each battery in String 1.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString1ResponseTestChangeEntry

battManString1ResponseTestChangeEntry 1.3.6.1.4.1.318.1.1.16.13.5.1
The string to get data from.
OBJECT-TYPE    
  BattManString1ResponseTestChangeEntry  

battManString1ResponseTestChangeIndex 1.3.6.1.4.1.318.1.1.16.13.5.1.1
Index of the entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString1ResponseTestChangeData 1.3.6.1.4.1.318.1.1.16.13.5.1.2
The battery response test change in percent.
OBJECT-TYPE    
  INTEGER  

battManString2OhmicValueLastDischargeInfo 1.3.6.1.4.1.318.1.1.16.13.6
Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded.
OBJECT-TYPE    
  DisplayString  

battManString2OhmicValueTableSize 1.3.6.1.4.1.318.1.1.16.13.7
The number of entries in the battManString2OhmicValueTable.
OBJECT-TYPE    
  INTEGER  

battManString2OhmicValueTable 1.3.6.1.4.1.318.1.1.16.13.8
Allows for getting ohmic value information from each battery in String 2.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString2OhmicValueEntry

battManString2OhmicValueEntry 1.3.6.1.4.1.318.1.1.16.13.8.1
The string to get data from.
OBJECT-TYPE    
  BattManString2OhmicValueEntry  

battManString2OhmicValueIndex 1.3.6.1.4.1.318.1.1.16.13.8.1.1
Index of battery calibration entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString2OhmicValueData 1.3.6.1.4.1.318.1.1.16.13.8.1.2
The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors.
OBJECT-TYPE    
  INTEGER  

battManString2ResponseTestChangeTableSize 1.3.6.1.4.1.318.1.1.16.13.9
The number of entries in the battManString2ResponseTestChangeTable.
OBJECT-TYPE    
  INTEGER  

battManString2ResponseTestChangeTable 1.3.6.1.4.1.318.1.1.16.13.10
Allows for getting response test change information from each battery in String 2.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManString2ResponseTestChangeEntry

battManString2ResponseTestChangeEntry 1.3.6.1.4.1.318.1.1.16.13.10.1
The string to get data from.
OBJECT-TYPE    
  BattManString2ResponseTestChangeEntry  

battManString2ResponseTestChangeIndex 1.3.6.1.4.1.318.1.1.16.13.10.1.1
Index of the entries in the table.
OBJECT-TYPE    
  INTEGER  

battManString2ResponseTestChangeData 1.3.6.1.4.1.318.1.1.16.13.10.1.2
The battery response test change in percent.
OBJECT-TYPE    
  INTEGER  

battManUnitStatus 1.3.6.1.4.1.318.1.1.16.14
OBJECT IDENTIFIER    

battManUnitStatusTableSize 1.3.6.1.4.1.318.1.1.16.14.1
The number of entries in the battManUnitStatusTable.
OBJECT-TYPE    
  INTEGER  

battManUnitStatusTable 1.3.6.1.4.1.318.1.1.16.14.2
Allows for getting status information from each unit in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    BattManUnitStatusEntry

battManUnitStatusEntry 1.3.6.1.4.1.318.1.1.16.14.2.1
The unit to get data from.
OBJECT-TYPE    
  BattManUnitStatusEntry  

battManUnitStatusIndex 1.3.6.1.4.1.318.1.1.16.14.2.1.1
Index of unit status entries in the table.
OBJECT-TYPE    
  INTEGER  

battManUnitStatusSerialNumber 1.3.6.1.4.1.318.1.1.16.14.2.1.2
The battery manager unit serial number character string. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

battManUnitHardwareRev 1.3.6.1.4.1.318.1.1.16.14.2.1.3
The battery manager unit hardware revision. This value is set at the factory.
OBJECT-TYPE    
  INTEGER  

battManUnitFirmwareRev 1.3.6.1.4.1.318.1.1.16.14.2.1.4
The battery manager unit firmware revision. This value is set at the factory and can change with firmware update.
OBJECT-TYPE    
  INTEGER  

battManUnitCommLoss 1.3.6.1.4.1.318.1.1.16.14.2.1.5
When set to alarm(2), indicates the system has lost communication with the unit.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

battManUnitRelayStuck 1.3.6.1.4.1.318.1.1.16.14.2.1.6
When set to alarm(2), indicates the unit monitor relay is stuck.
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

xATS 1.3.6.1.4.1.318.1.1.17
OBJECT IDENTIFIER    

xATSIdent 1.3.6.1.4.1.318.1.1.17.1
OBJECT IDENTIFIER    

xATSIdentProductName 1.3.6.1.4.1.318.1.1.17.1.1
The name of the transfer switch unit.
OBJECT-TYPE    
  DisplayString  

xATSIdentHardwareRev 1.3.6.1.4.1.318.1.1.17.1.2
The hardware revision of the transfer switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSIdentFirmwareAppRev 1.3.6.1.4.1.318.1.1.17.1.3
An ID string identifying the application firmware revision of the transfer switch.
OBJECT-TYPE    
  DisplayString  

xATSIdentFirmwareAppOSRev 1.3.6.1.4.1.318.1.1.17.1.4
An ID string identifying the application operating system firmware revision of the transfer switch.
OBJECT-TYPE    
  DisplayString  

xATSIdentFirmwareControllerRev 1.3.6.1.4.1.318.1.1.17.1.5
An ID string identifying the transfer switch controller firmware revision.
OBJECT-TYPE    
  DisplayString  

xATSIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.17.1.6
The date when the transfer switch was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSIdentModelNumber 1.3.6.1.4.1.318.1.1.17.1.7
A character string identifying the model number of the transfer switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSIdentSerialNumber 1.3.6.1.4.1.318.1.1.17.1.8
A character string identifying the serial number of the transfer switch. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSDevice 1.3.6.1.4.1.318.1.1.17.2
OBJECT IDENTIFIER    

xATSDeviceServiceType 1.3.6.1.4.1.318.1.1.17.2.1
The type of utility input to the transfer switch. Either 3 wires (delta), or 4 wires (wye).
OBJECT-TYPE    
  INTEGER threeWire(1), fourWire(2)  

xATSDeviceNominalVoltage 1.3.6.1.4.1.318.1.1.17.2.2
The nominal line-to-neutral system voltage. Measured in Volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSDeviceNominalFrequency 1.3.6.1.4.1.318.1.1.17.2.3
The nominal system frequency. Measured in tenths of Hertz. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSDeviceTransferSwitchRating 1.3.6.1.4.1.318.1.1.17.2.4
The rating of the transfer switch. Measured in Amps.
OBJECT-TYPE    
  INTEGER  

xATSDeviceDCBackUpPresent 1.3.6.1.4.1.318.1.1.17.2.5
Indicates if a DC backup is present or not.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSSwitch 1.3.6.1.4.1.318.1.1.17.3
OBJECT IDENTIFIER    

xATSSwitchStatus 1.3.6.1.4.1.318.1.1.17.3.1
OBJECT IDENTIFIER    

xATSSwitchStatusSelectedSource 1.3.6.1.4.1.318.1.1.17.3.1.1
The source which is currently selected, i.e. supplying power to the load.
OBJECT-TYPE    
  INTEGER none(1), source1(2), source2(3), fault(4), unknown(5)  

xATSSwitchStatusOperationalMode 1.3.6.1.4.1.318.1.1.17.3.1.2
The current operating mode of the transfer switch. When the ATS is in automatic mode, generator starting and ATS transferring is all done automatically as needed based on the state of source 1. Automatic operation is halted when the ATS is in either of the notInAuto modes. A mode of notInAuto indicates that the automatic operation switch is in the disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID. The notInAutoAbnormal condition indicates that an abnormal condition has caused the transfer switch to halt automatic operation. In this case, traps can indicate the exact problem. In the case of notInAutoAbnormal, refer to the operation manual for details on how debug the condition and restore automatic operation.
OBJECT-TYPE    
  INTEGER automatic(1), notInAutoAbnormal(2), notInAuto(3), unknown(4)  

xATSSwitchStatusAutomaticOperationSwitch 1.3.6.1.4.1.318.1.1.17.3.1.3
The position of the automatic operation switch on the front of the transfer switch.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), unknown(3)  

xATSSwitchStatusEngineStartSignal 1.3.6.1.4.1.318.1.1.17.3.1.4
The position of the Start/Stop contact which signals the generator engine to start/run. When the ATS is in automatic mode, generator starting/stopping is under ATS control.
OBJECT-TYPE    
  INTEGER run(1), stop(2), unknown(3)  

xATSSwitchSettings 1.3.6.1.4.1.318.1.1.17.3.2
OBJECT IDENTIFIER    

xATSSwitchSettingsLowVoltageTransferPoint 1.3.6.1.4.1.318.1.1.17.3.2.1
The lowest acceptable voltage condition at source 1. When any phase of source 1 is lower than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsHighVoltageTransferPoint 1.3.6.1.4.1.318.1.1.17.3.2.2
The highest acceptable voltage condition at source 1. When any phase of source 1 is greater than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsMaxFrequencyDeviation 1.3.6.1.4.1.318.1.1.17.3.2.3
The maximum acceptable frequency deviation condition from nominal at source 1. When source 1 frequency is outside the specified range, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in tenths of Hertz above or below nominal. A value of zero indicates that frequency is ignored when determining source quality. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsMinPhaseBalance 1.3.6.1.4.1.318.1.1.17.3.2.4
The minimum required phase balance at source 1. When the percentage difference between the minimum and maximum phase voltage measurements at source 1 is greater than this value, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified as a percentage. A value of zero indicates that phase balance is ignored when determining source quality. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsNominalRotation 1.3.6.1.4.1.318.1.1.17.3.2.5
The nominal phase rotation (or phase sequence) required by the load. For certain types of equipment, such as rotating machinery, phase rotation is critical for proper operation as it determines the direction which motors will rotate (clockwise or counterclockwise). Source quality will be seen as bad if the rotation measured at that ATS input does not match this setting. If this setting is set to any, phase rotation is ignored.
OBJECT-TYPE    
  INTEGER abc(1), cba(2), any(3), unknown(4)  

xATSSwitchSettingsAllowClosedTransfer 1.3.6.1.4.1.318.1.1.17.3.2.6
This setting enables seamless (closed) transfers between sources. When possible, both source 1 and source 2 are closed to the output for a brief time. If closed transfer is not possible within the amount of time specified by the xATSSwitchSettingsMaxSyncTime OID, an open transfer will be executed.
OBJECT-TYPE    
  INTEGER yes(1), no(2), unknown(3)  

xATSSwitchSettingsMaxSyncTime 1.3.6.1.4.1.318.1.1.17.3.2.7
When attempting/seeking to perform a closed transfer, this setting defines the maximum time allowed before the transfer switch will give up and perform an open transfer. Specified in seconds. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsNeutralTransferTime 1.3.6.1.4.1.318.1.1.17.3.2.8
This setting defines how long both source 1 and source 2 will be disconnected from the output, during an open transfer. Specified in seconds. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSwitchSettingsClearLatchedAlarms 1.3.6.1.4.1.318.1.1.17.3.2.9
Clears any latched alarm conditions.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSSwitchSettingsSetToFactoryDefaults 1.3.6.1.4.1.318.1.1.17.3.2.10
Sets all transfer switch settings to factory default values.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSSwitchTimers 1.3.6.1.4.1.318.1.1.17.3.3
OBJECT IDENTIFIER    

xATSSwitchTimersTableSize 1.3.6.1.4.1.318.1.1.17.3.3.1
The number of transfer switch timer entries.
OBJECT-TYPE    
  INTEGER  

xATSSwitchTimersTable 1.3.6.1.4.1.318.1.1.17.3.3.2
A list of timers supported by ATS. The number of entries is contained in the xATSSwitchTimersTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSwitchTimersEntry

xATSSwitchTimersEntry 1.3.6.1.4.1.318.1.1.17.3.3.2.1
An entry containing information about an individual ATS timer.
OBJECT-TYPE    
  XATSSwitchTimersEntry  

xATSSwitchTimersIndex 1.3.6.1.4.1.318.1.1.17.3.3.2.1.1
Index of timer entries in the table.
OBJECT-TYPE    
  INTEGER  

xATSSwitchTimersName 1.3.6.1.4.1.318.1.1.17.3.3.2.1.2
Name of the individual timer.Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers.
OBJECT-TYPE    
  DisplayString  

xATSSwitchTimersAbort 1.3.6.1.4.1.318.1.1.17.3.3.2.1.3
This aborts the individual timer.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSSwitchTimersStatus 1.3.6.1.4.1.318.1.1.17.3.3.2.1.4
The status of the individual timer. Designates whether this timer entry is currently running or inactive.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

xATSSwitchTimersRemainingTime 1.3.6.1.4.1.318.1.1.17.3.3.2.1.5
The time remaining for this timer entry. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

xATSSwitchTimersDelaySetting 1.3.6.1.4.1.318.1.1.17.3.3.2.1.6
The delay settings associated with this timer entry. When this timer entry is active, the timer value must exceed this setting before the ATS behavior associated with this timer is executed. Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers.
OBJECT-TYPE    
  INTEGER  

xATSSwitchBlockMap 1.3.6.1.4.1.318.1.1.17.3.4
OBJECT IDENTIFIER    

xATSSwitchBlockMapTableSize 1.3.6.1.4.1.318.1.1.17.3.4.1
The number of blocking map entries, or how many ATS actions can be blocked.
OBJECT-TYPE    
  INTEGER  

xATSSwitchBlockMapTable 1.3.6.1.4.1.318.1.1.17.3.4.2
A list of blocking maps supported by the ATS. The number of entries is contained in the xATSSwitchBlockMapTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSwitchBlockMapEntry

xATSSwitchBlockMapEntry 1.3.6.1.4.1.318.1.1.17.3.4.2.1
An entry containing information about a specific ATS blocking map.
OBJECT-TYPE    
  XATSSwitchBlockMapEntry  

xATSSwitchBlockMapIndex 1.3.6.1.4.1.318.1.1.17.3.4.2.1.1
Index of blocking map entries in the table.
OBJECT-TYPE    
  INTEGER  

xATSSwitchBlockMapName 1.3.6.1.4.1.318.1.1.17.3.4.2.1.2
A string describing the ATS action to be blocked.
OBJECT-TYPE    
  DisplayString  

xATSSwitchBlockMapStatus 1.3.6.1.4.1.318.1.1.17.3.4.2.1.3
Represents the status of this blocking map entry, in bit-mapped format. A non-zero value indicates that this entry's ATS action is currently being blocked. The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc). bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4.
OBJECT-TYPE    
  INTEGER  

xATSSwitchBlockMapSetting 1.3.6.1.4.1.318.1.1.17.3.4.2.1.4
This setting designates the inputs that block the ATS action The mapping is specified as a bit-field, where each bit set indicates the input that blocks the ATS action associated with the entry. bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4.
OBJECT-TYPE    
  INTEGER  

xATSSwitchStatistics 1.3.6.1.4.1.318.1.1.17.3.5
OBJECT IDENTIFIER    

xATSSwitchStatisticsTableSize 1.3.6.1.4.1.318.1.1.17.3.5.1
The number of transfer switch statistics entries.
OBJECT-TYPE    
  INTEGER  

xATSSwitchStatisticsTable 1.3.6.1.4.1.318.1.1.17.3.5.2
A list of statistics supported by ATS. The number of entries is contained in the xATSSwitchStatisticsTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSwitchStatisticsEntry

xATSSwitchStatisticsEntry 1.3.6.1.4.1.318.1.1.17.3.5.2.1
An entry containing information about an individual ATS statistic.
OBJECT-TYPE    
  XATSSwitchStatisticsEntry  

xATSSwitchStatisticsIndex 1.3.6.1.4.1.318.1.1.17.3.5.2.1.1
Index of ATS statistics entries in the table.
OBJECT-TYPE    
  INTEGER  

xATSSwitchStatisticsName 1.3.6.1.4.1.318.1.1.17.3.5.2.1.2
This is the name of the ATS statistic associated with this entry.
OBJECT-TYPE    
  DisplayString  

xATSSwitchStatisticsValue 1.3.6.1.4.1.318.1.1.17.3.5.2.1.3
This is the value of the ATS statistic associated with this entry.
OBJECT-TYPE    
  DisplayString  

xATSSwitchStatisticsReset 1.3.6.1.4.1.318.1.1.17.3.5.2.1.4
This will reset the individual ATS statistic associated with this entry.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSACMonitoringPoint 1.3.6.1.4.1.318.1.1.17.4
OBJECT IDENTIFIER    

xATSSource1 1.3.6.1.4.1.318.1.1.17.4.1
OBJECT IDENTIFIER    

xATSSource1Name 1.3.6.1.4.1.318.1.1.17.4.1.1
String used to identify source 1.
OBJECT-TYPE    
  DisplayString  

xATSSource1Position 1.3.6.1.4.1.318.1.1.17.4.1.2
The current position of the switch at source 1.
OBJECT-TYPE    
  INTEGER open(1), closed(2), tripped(3), unknown(4)  

xATSSource1Frequency 1.3.6.1.4.1.318.1.1.17.4.1.3
The frequency at source 1 in tenths of Hertz. -1 if unavailable.
OBJECT-TYPE    
  INTEGER  

xATSSource1Quality 1.3.6.1.4.1.318.1.1.17.4.1.4
The current line quality of source 1.
OBJECT-TYPE    
  INTEGER sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)  

xATSSource1Rotation 1.3.6.1.4.1.318.1.1.17.4.1.5
The phase rotation measured at the source 1 input of the ATS. The sequence is a reference to the order in which the three phases pass the zero-crossing boundary in time.
OBJECT-TYPE    
  INTEGER abc(1), cba(2), unknown(3)  

xATSSource1TableSize 1.3.6.1.4.1.318.1.1.17.4.1.6
The number of input voltage entries at the source 1 input of the ATS.
OBJECT-TYPE    
  INTEGER  

xATSSource1PhaseTable 1.3.6.1.4.1.318.1.1.17.4.1.7
A list of voltage table entries for source 1. The number of entries are the phase entries. The number of entries is contained in the xATSSource1TableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSource1PhaseEntry

xATSSource1PhaseEntry 1.3.6.1.4.1.318.1.1.17.4.1.7.1
An entry containing information applicable to a particular input voltage phase at the source 1 input of the ATS.
OBJECT-TYPE    
  XATSSource1PhaseEntry  

xATSSource1Index 1.3.6.1.4.1.318.1.1.17.4.1.7.1.1
Description of each phase utilized at source 1.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xATSSource1VoltageLtoL 1.3.6.1.4.1.318.1.1.17.4.1.7.1.2
Source 1 line-to-line input voltage. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xATSSource1VoltageLtoN 1.3.6.1.4.1.318.1.1.17.4.1.7.1.3
Source 1 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type.
OBJECT-TYPE    
  INTEGER  

xATSSource2 1.3.6.1.4.1.318.1.1.17.4.2
OBJECT IDENTIFIER    

xATSSource2Name 1.3.6.1.4.1.318.1.1.17.4.2.1
String used to identify source 2.
OBJECT-TYPE    
  DisplayString  

xATSSource2Position 1.3.6.1.4.1.318.1.1.17.4.2.2
The current position of the switch at source 2.
OBJECT-TYPE    
  INTEGER open(1), closed(2), tripped(3), unknown(4)  

xATSSource2Frequency 1.3.6.1.4.1.318.1.1.17.4.2.3
The frequency at source 2 in tenths of Hertz. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSource2Quality 1.3.6.1.4.1.318.1.1.17.4.2.4
The current line quality of source 2.
OBJECT-TYPE    
  INTEGER sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)  

xATSSource2Rotation 1.3.6.1.4.1.318.1.1.17.4.2.5
The phase rotation measured at the source 2 input of the ATS. -1 if not available.
OBJECT-TYPE    
  INTEGER abc(1), cba(2), unknown(3)  

xATSSource2TableSize 1.3.6.1.4.1.318.1.1.17.4.2.6
The number of input voltage entries at the source 2 input of the ATS.
OBJECT-TYPE    
  INTEGER  

xATSSource2PhaseTable 1.3.6.1.4.1.318.1.1.17.4.2.7
A list of voltage table entries for the source 2. The number of entries are the phase entries. The number of entries is contained in the xATSSource2TableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSource2PhaseEntry

xATSSource2PhaseEntry 1.3.6.1.4.1.318.1.1.17.4.2.7.1
An entry containing information applicable to a particular input voltage phase at the source 2 input of the ATS.
OBJECT-TYPE    
  XATSSource2PhaseEntry  

xATSSource2Index 1.3.6.1.4.1.318.1.1.17.4.2.7.1.1
Description of each phase utilized at the source 2.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xATSSource2VoltageLtoL 1.3.6.1.4.1.318.1.1.17.4.2.7.1.2
Source 2 line-to-line input voltage. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

xATSSource2VoltageLtoN 1.3.6.1.4.1.318.1.1.17.4.2.7.1.3
Source 2 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutput 1.3.6.1.4.1.318.1.1.17.4.3
OBJECT IDENTIFIER    

xATSSystemOutputFrequency 1.3.6.1.4.1.318.1.1.17.4.3.1
The system output frequency in tenths of Hertz.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputTotalPower 1.3.6.1.4.1.318.1.1.17.4.3.2
Shows the total system output power in tenths of kW.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputTotalApparentPower 1.3.6.1.4.1.318.1.1.17.4.3.3
Shows the total system output power in tenths of kVA.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputTotalPowerFactor 1.3.6.1.4.1.318.1.1.17.4.3.4
Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00) Specified in hundredths.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputFrequencyTolerance 1.3.6.1.4.1.318.1.1.17.4.3.5
Shows the panel output frequency tolerance in +/- Hertz.
OBJECT-TYPE    
  INTEGER freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)  

xATSSystemOutputOverVoltThreshold 1.3.6.1.4.1.318.1.1.17.4.3.6
Threshold above which an output over voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputUnderVoltThreshold 1.3.6.1.4.1.318.1.1.17.4.3.7
Threshold below which an output under voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputOverCurrentThreshold 1.3.6.1.4.1.318.1.1.17.4.3.8
Threshold above which an over current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..100  

xATSSystemOutputUnderCurrentThreshold 1.3.6.1.4.1.318.1.1.17.4.3.9
Threshold below which an under current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled.
OBJECT-TYPE    
  INTEGER 0..100  

xATSSystemOutputAlarmDelayThreshold 1.3.6.1.4.1.318.1.1.17.4.3.10
Delay the generation of an output alarm. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputTableSize 1.3.6.1.4.1.318.1.1.17.4.3.11
The number of system output phase entries.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputPhaseTable 1.3.6.1.4.1.318.1.1.17.4.3.12
A list of system output table entries. The number of entries is contained in the xATSSystemOutputTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSSystemOutputPhaseEntry

xATSSystemOutputPhaseEntry 1.3.6.1.4.1.318.1.1.17.4.3.12.1
An entry containing information applicable to a particular system output phase.
OBJECT-TYPE    
  XATSSystemOutputPhaseEntry  

xATSSystemOutputPhaseIndex 1.3.6.1.4.1.318.1.1.17.4.3.12.1.1
Description of each system output phase utilized in this device.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xATSSystemOutputVoltageLtoL 1.3.6.1.4.1.318.1.1.17.4.3.12.1.2
Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputVoltageLtoN 1.3.6.1.4.1.318.1.1.17.4.3.12.1.3
Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. -1 for a 3-wire service type or if not available.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputPhaseCurrent 1.3.6.1.4.1.318.1.1.17.4.3.12.1.4
System load current per phase. Measured in Amps. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputPower 1.3.6.1.4.1.318.1.1.17.4.3.12.1.5
System output power per phase. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputApparentPower 1.3.6.1.4.1.318.1.1.17.4.3.12.1.6
system output power per phase. Measured in tenths of kVA.
OBJECT-TYPE    
  INTEGER  

xATSSystemOutputPowerFactor 1.3.6.1.4.1.318.1.1.17.4.3.12.1.7
indicates the power factor of the system output per phase. A value of 100 representing a unity power factor (1.00). Measured in hundredths.
OBJECT-TYPE    
  INTEGER  

xATSTesting 1.3.6.1.4.1.318.1.1.17.5
OBJECT IDENTIFIER    

xATSTestingStatus 1.3.6.1.4.1.318.1.1.17.5.1
OBJECT IDENTIFIER    

xATSTestingStatusSelectTestProcess 1.3.6.1.4.1.318.1.1.17.5.1.1
Type of tests that can be selected when no test has been scheduled. engineStartTest and systemLoadTest may be selected when no tests are running. Tests that are selected may be canceled manually.
OBJECT-TYPE    
  INTEGER engineStartTest(1), systemLoadTest(2), generatorHoldTest(3), cancelTest(4)  

xATSTestingStatusTestStatus 1.3.6.1.4.1.318.1.1.17.5.1.2
The present system test status/state.
OBJECT-TYPE    
  INTEGER noTestInProcess(1), testPending(2), startingEngine(3), engineWarmingUp(4), awaitingTransferToS2(5), testingWithLoad(6), awaitingRetransferToS1(7), testingWithoutLoad(8), stoppingEngine(9), holdingOnGenerator(10)  

xATSTestingStatusProfileWarmupTime 1.3.6.1.4.1.318.1.1.17.5.1.3
The amount of time that the generator will warm up during a test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value engineWarmingUp. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

xATSTestingStatusProfileLoadedTime 1.3.6.1.4.1.318.1.1.17.5.1.4
The amount of time that ATS will apply the system load to the generator during a system load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithLoad. Specified in minutes.
OBJECT-TYPE    
  INTEGER  

xATSTestingStatusProfileUnloadedTime 1.3.6.1.4.1.318.1.1.17.5.1.5
The amount of time that the generator will run following the warm up portion of a start test, or the loaded portion of a load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithoutLoad. Specified in seconds.
OBJECT-TYPE    
  INTEGER  

xATSTestingResults 1.3.6.1.4.1.318.1.1.17.5.2
OBJECT IDENTIFIER    

xATSTestingResultsLastDateOfTest 1.3.6.1.4.1.318.1.1.17.5.2.1
Date of the last test that was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the dd/mm/yyyy format, or 'none' if not available.
OBJECT-TYPE    
  DisplayString  

xATSTestingResultsLastResult 1.3.6.1.4.1.318.1.1.17.5.2.2
The result of the last ATS/generator system test.
OBJECT-TYPE    
  INTEGER noResultsAvailable(1), startTestPassed(2), loadTestPassed(3), startSignalFailure(4), failedGenNotInAuto(5), failedGenEmerStop(6), failedGenShutdown(7), failedGenDidNotStart(8), failedS2NeverGood(9), genFailedDuringWarmup(10), failureOnXferToS1(11), genFailedLoaded(12), failureOnRexferToS2(13), failedOnCooldown(14), genFailedToStop(15), failedAtsInternalFault(16), failedAtsNotInAuto(17), canceledManualTest(18), canceledScheduledTest(19)  

xATSTestingResultsTestLastTestTime 1.3.6.1.4.1.318.1.1.17.5.2.3
Time of day at which the last test was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the hh:mm:ss format, or 'none' if not available.
OBJECT-TYPE    
  DisplayString  

xATSTestingResultsLastCrankDuration 1.3.6.1.4.1.318.1.1.17.5.2.4
The time spent cranking the generator before it started during the last test. Specified in seconds, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSTestingResultsLastWarmupDuration 1.3.6.1.4.1.318.1.1.17.5.2.5
The time spent in the engineWarmingUp state during the last system test. Specified in seconds, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSTestingResultsLastLoadedDuration 1.3.6.1.4.1.318.1.1.17.5.2.6
The time spent in the testingWithLoad state during the last system test. Specified in seconds, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSTestingResultsLastUnloadedDuration 1.3.6.1.4.1.318.1.1.17.5.2.7
The time spent in the testingWithoutLoad state during the last system test. Specified in seconds, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSTestingSchedule 1.3.6.1.4.1.318.1.1.17.5.3
OBJECT IDENTIFIER    

xATSTestingScheduleFrequency 1.3.6.1.4.1.318.1.1.17.5.3.1
The frequency of running scheduled tests.
OBJECT-TYPE    
  INTEGER never(1), daily(2), weekly(3), monthly(4)  

xATSTestingScheduleTestDay 1.3.6.1.4.1.318.1.1.17.5.3.2
The desired day for the scheduled test. This object applies only when the xATSTestingScheduleFrequency OID is set to weekly or monthly. For weekly test frequency, the string is the day the test will be run. For monthly test frequency, the string indicates the day, and the instance within the month. For example, for monthly frequency: 2nd Sunday, 3rd Monday, 4th Tuesday, for weekly frequency: Sunday, Monday, Tuesday.
OBJECT-TYPE    
  DisplayString  

xATSTestingScheduleTestTime 1.3.6.1.4.1.318.1.1.17.5.3.3
The time of day that the scheduled test will occur. Specified in the format hh:mm.
OBJECT-TYPE    
  DisplayString  

xATSTestingScheduleTestWithLoadInterval 1.3.6.1.4.1.318.1.1.17.5.3.4
This setting specifies which system tests should include applying the load to the generator. The applyLoadMonthlyDetailed entry in the list will apply load once, for each month represented in the xATSTestingScheduleTestWithLoadSelectMonth OID.
OBJECT-TYPE    
  INTEGER applyLoadEveryTest(1), neverApplyLoad(2), applyLoadMonthly(3), applyLoadMonthlyDetailed(4)  

xATSTestingScheduleTestWithLoadSelectMonth 1.3.6.1.4.1.318.1.1.17.5.3.5
The detailed selection for testing with load on a month-by-month basis. This object is applicable when the xATSTestingScheduleTestWithLoadInterval is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored. Format for this string is a comma-separated entry of months. For example: Jan,Mar,Dec. The string will return 'No Months Scheduled' if no months have been selected.
OBJECT-TYPE    
  DisplayString  

xATSTestingScheduleNextTestDate 1.3.6.1.4.1.318.1.1.17.5.3.6
The date of the next scheduled test, in the format dd-mmm-yyyy.
OBJECT-TYPE    
  DisplayString  

xATSTestingSimulatePowerFail 1.3.6.1.4.1.318.1.1.17.5.4
OBJECT IDENTIFIER    

xATSTestingSimulatePowerFailTest 1.3.6.1.4.1.318.1.1.17.5.4.1
This object executes a simulated power failure for the duration indicated. Simulation can be aborted by selecting cancelSimulation.
OBJECT-TYPE    
  INTEGER cancelSimulation(1), fiveSecondsSimulation(2), tenSecondsSimulation(3), thirtySecondsSimulation(4), oneMinuteSimulation(5), threeMinutesSimulation(6), fiveMinutesSimulation(7), tenMinutesSimulation(8)  

xATSTestingSimulatePowerFailTimeRemaining 1.3.6.1.4.1.318.1.1.17.5.4.2
Indicates the time remaining in seconds, for a simulated power failure. a value of zero indicates that simulated power failure is not active.
OBJECT-TYPE    
  INTEGER  

xATSInputContacts 1.3.6.1.4.1.318.1.1.17.6
OBJECT IDENTIFIER    

xATSInputContactNumContacts 1.3.6.1.4.1.318.1.1.17.6.1
The number of contacts supported by the ATS.
OBJECT-TYPE    
  INTEGER  

xATSInputContactTableSize 1.3.6.1.4.1.318.1.1.17.6.2
The number of input contact entries.
OBJECT-TYPE    
  INTEGER  

xATSInputContactTable 1.3.6.1.4.1.318.1.1.17.6.3
A list of contacts supported by the ATS. The number of entries is contained in the xATSInputContactTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSInputContactEntry

xATSInputContactEntry 1.3.6.1.4.1.318.1.1.17.6.3.1
A contact entry containing information for a given contact.
OBJECT-TYPE    
  XATSInputContactEntry  

xATSInputContactNumber 1.3.6.1.4.1.318.1.1.17.6.3.1.1
An index identifying the contact on the ATS.
OBJECT-TYPE    
  INTEGER  

xATSInputContactName 1.3.6.1.4.1.318.1.1.17.6.3.1.2
The description of the purpose/use of the contact.
OBJECT-TYPE    
  DisplayString  

xATSInputContactNormalState 1.3.6.1.4.1.318.1.1.17.6.3.1.3
The normal operating position of the contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xATSInputContactCurrentState 1.3.6.1.4.1.318.1.1.17.6.3.1.4
This value indicates the current state of the contact.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xATSOutputRelays 1.3.6.1.4.1.318.1.1.17.7
OBJECT IDENTIFIER    

xATSOutputRelayNumRelays 1.3.6.1.4.1.318.1.1.17.7.1
The number of output relays supported by the ATS.
OBJECT-TYPE    
  INTEGER  

xATSOutputRelayTableSize 1.3.6.1.4.1.318.1.1.17.7.2
The number of output relay entries.
OBJECT-TYPE    
  INTEGER  

xATSOutputRelayTable 1.3.6.1.4.1.318.1.1.17.7.3
A list of output relays supported by the ATS. The number of entries is contained in the xATSOutputRelayTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSOutputRelayEntry

xATSOutputRelayEntry 1.3.6.1.4.1.318.1.1.17.7.3.1
A output relay entry containing information for a given contact.
OBJECT-TYPE    
  XATSOutputRelayEntry  

xATSOutputRelayNumber 1.3.6.1.4.1.318.1.1.17.7.3.1.1
An index identifying the output relay on the ATS.
OBJECT-TYPE    
  INTEGER  

xATSOutputRelayName 1.3.6.1.4.1.318.1.1.17.7.3.1.2
The description of the purpose/use of the output relay.
OBJECT-TYPE    
  DisplayString  

xATSOutputRelayNormalState 1.3.6.1.4.1.318.1.1.17.7.3.1.3
The normal operating position of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xATSOutputRelayCurrentState 1.3.6.1.4.1.318.1.1.17.7.3.1.4
This value indicates the current state of the output relay.
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

xATSMisc 1.3.6.1.4.1.318.1.1.17.8
OBJECT IDENTIFIER    

generator 1.3.6.1.4.1.318.1.1.18
OBJECT IDENTIFIER    

xATSGenerator 1.3.6.1.4.1.318.1.1.18.1
OBJECT IDENTIFIER    

xATSGeneratorIdent 1.3.6.1.4.1.318.1.1.18.1.1
OBJECT IDENTIFIER    

xATSGeneratorIdentModelNumber 1.3.6.1.4.1.318.1.1.18.1.1.1
A character string identifying the model number of the generator. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorIdentSerialNumber 1.3.6.1.4.1.318.1.1.18.1.1.2
A character string identifying the serial number of the generator. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorIdentDateofManufacture 1.3.6.1.4.1.318.1.1.18.1.1.3
A character string identifying when the generator was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorIdentVoltageConfiguration 1.3.6.1.4.1.318.1.1.18.1.1.4
The voltage for which the generator's alternator is designed. Specified in Volts line-to-line.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorIdentMaxPowerRating 1.3.6.1.4.1.318.1.1.18.1.1.5
The max power rating of the generator. Specified in kW.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorIdentAlternatorFrequency 1.3.6.1.4.1.318.1.1.18.1.1.6
The frequency for which the generator's alternator is designed. Specified in Hertz.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorStatus 1.3.6.1.4.1.318.1.1.18.1.2
OBJECT IDENTIFIER    

xATSGeneratorStatusGeneratorName 1.3.6.1.4.1.318.1.1.18.1.2.1
The name or label for the generator connected to the source 2 of the ATS.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorStatusOperational 1.3.6.1.4.1.318.1.1.18.1.2.2
The operational status of the generator. unavailable when unrecognized status is received.
OBJECT-TYPE    
  INTEGER nocomm(1), off(2), ready(3), starting(4), idle(5), running(6), normalStop(7), emergencyStop(8), notInAuto(9), shutdown(10), unknown(11)  

xATSGeneratorStatusModeSwitchPosition 1.3.6.1.4.1.318.1.1.18.1.2.3
The position of the generator's auto-mode switch. In automatic mode, the generator is started and stopped via the remote start contact, which has state indicated in the xATSGeneratorStatusRemoteStart OID. In manual mode generator start/stop control is via local command only. Off prevents the generator from running.
OBJECT-TYPE    
  INTEGER off(1), manual(2), automatic(3), unknown(4)  

xATSGeneratorStatusRemoteStart 1.3.6.1.4.1.318.1.1.18.1.2.4
The status of the generator's remote start contact, which is provided as an output from the transfer switch to start/stop the generator when in automatic mode.
OBJECT-TYPE    
  INTEGER stop(1), run(2), unknown(3)  

xATSGeneratorAdvStatus 1.3.6.1.4.1.318.1.1.18.1.3
OBJECT IDENTIFIER    

xATSGeneratorAdvStatusBatteryVoltage 1.3.6.1.4.1.318.1.1.18.1.3.1
The voltage of the generator's starting battery. Measured in tenths of VDC, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorAdvStatusOilPressure 1.3.6.1.4.1.318.1.1.18.1.3.2
The generator's engine oil pressure. Measured in tenths of Psi or kPa, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorAdvStatusCoolantTemperature 1.3.6.1.4.1.318.1.1.18.1.3.3
Current coolant temperature in the generator. Measured in degrees Celsius or Fahrenheit, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorAdvStatusEngineRPM 1.3.6.1.4.1.318.1.1.18.1.3.4
Current engine speed of the generator. Measured in RPM, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorAdvStatusOilLevel 1.3.6.1.4.1.318.1.1.18.1.3.5
Indicates adequate oil level in the generator.
OBJECT-TYPE    
  INTEGER ok(1), low(2), unknown(3)  

xATSGeneratorAdvStatusCoolantLevel 1.3.6.1.4.1.318.1.1.18.1.3.6
Indicates adequate coolant level in the generator.
OBJECT-TYPE    
  INTEGER ok(1), low(2), unknown(3)  

xATSGeneratorOutput 1.3.6.1.4.1.318.1.1.18.1.4
OBJECT IDENTIFIER    

xATSGeneratorOutputFrequency 1.3.6.1.4.1.318.1.1.18.1.4.1
The output frequency of the generator. Measured in tenths of Hertz, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputTotalPower 1.3.6.1.4.1.318.1.1.18.1.4.2
The total output power of the generator. Measured in tenths of tenths of kW, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputTotalApparentPower 1.3.6.1.4.1.318.1.1.18.1.4.3
The total output power of the generator. Measured in tenths of kVA, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputTotalPowerFactor 1.3.6.1.4.1.318.1.1.18.1.4.4
Indicates the total load power factor of the generator. A value of 100 representing a unity power factor (1.00), or -1 when if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputTableSize 1.3.6.1.4.1.318.1.1.18.1.4.5
The number of generator output phase entries.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputPhaseTable 1.3.6.1.4.1.318.1.1.18.1.4.6
A list of generator output table entries. The number of entries is contained in the xATSGeneratorOutputTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    XATSGeneratorOutputPhaseEntry

xATSGeneratorOutputPhaseEntry 1.3.6.1.4.1.318.1.1.18.1.4.6.1
An entry containing information applicable to a particular generator output phase.
OBJECT-TYPE    
  XATSGeneratorOutputPhaseEntry  

xATSGeneratorOutputPhaseIndex 1.3.6.1.4.1.318.1.1.18.1.4.6.1.1
Description of each generator output phase utilized in this device.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

xATSGeneratorOutputVoltageLtoL 1.3.6.1.4.1.318.1.1.18.1.4.6.1.2
Line-to-line generator output voltage. Measured in Volts, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputVoltageLtoN 1.3.6.1.4.1.318.1.1.18.1.4.6.1.3
Line-to-neutral generator output voltage. Measured in volts, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputPhaseCurrent 1.3.6.1.4.1.318.1.1.18.1.4.6.1.4
Generator load current per phase. Measured in Amps, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputPower 1.3.6.1.4.1.318.1.1.18.1.4.6.1.5
Generator output power per phase. Measured in tenths of kW, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputApparentPower 1.3.6.1.4.1.318.1.1.18.1.4.6.1.6
Generator output power per phase. Measured in tenths of kVA, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorOutputPowerFactor 1.3.6.1.4.1.318.1.1.18.1.4.6.1.7
Indicates the load power factor of the generator output per phase. A value of 100 representing a unity power factor (1.00), or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettings 1.3.6.1.4.1.318.1.1.18.1.5
OBJECT IDENTIFIER    

xATSGeneratorSettingsVoltageAdjust 1.3.6.1.4.1.318.1.1.18.1.5.1
The voltage adjust of the generator. Specified in volts line-to-line, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsFrequencyAdjust 1.3.6.1.4.1.318.1.1.18.1.5.2
The frequency adjust of the generator. Specified in tenths of Hertz.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsStartDelay 1.3.6.1.4.1.318.1.1.18.1.5.3
The delay, in seconds, after the remote run signal is activated before the generator's engine will be cranked to start, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsStopDelay 1.3.6.1.4.1.318.1.1.18.1.5.4
The delay, in seconds, before the generator will stop after the remote run signal is deactivated, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsCrankCycleEnable 1.3.6.1.4.1.318.1.1.18.1.5.5
When Crank Cycle is enabled, the engine will be cranked up to the time specified by the xATSGeneratorSettingsCrankTime OID. If the generator's engine does not start, there will be a pause as specified by the xATSGeneratorSettingsCrankRestTime OID before the engine will be cranked again. This cycle is repeated as specified by the xATSGeneratorSettingsNumberCrank OID. When crank cycle is disabled, the generator's engine will be cranked continuously until it starts.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), unknown(3)  

xATSGeneratorSettingsCrankTime 1.3.6.1.4.1.318.1.1.18.1.5.6
The duration of engine cranking, in seconds, when starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsCrankRestTime 1.3.6.1.4.1.318.1.1.18.1.5.7
The pause duration, in seconds, following an unsuccessful attempt to start the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsNumberCrank 1.3.6.1.4.1.318.1.1.18.1.5.8
The number of failed crank attempts before giving up on starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorSettingsMetricUnit 1.3.6.1.4.1.318.1.1.18.1.5.9
Specifies the use of metric units in generator related OIDs, as well as on all other interfaces including the generator's local interface.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

xATSGeneratorService 1.3.6.1.4.1.318.1.1.18.1.6
OBJECT IDENTIFIER    

xATSGeneratorServiceTotalRunHoursLifetime 1.3.6.1.4.1.318.1.1.18.1.6.1
Total time that the generator engine has been run, over the life of the generator. Measured in hours. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceEngineStartsLifetime 1.3.6.1.4.1.318.1.1.18.1.6.2
Number of engine starts over the life of the generator. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceTotalkWhLifetime 1.3.6.1.4.1.318.1.1.18.1.6.3
Total kWh of operation over the life of the generator. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceTotalRunHoursSinceMaintenance 1.3.6.1.4.1.318.1.1.18.1.6.4
Total time that the generator engine has been run, since last service maintenance. Measured in tenths of hours. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceEngineStartsSinceMaintenance 1.3.6.1.4.1.318.1.1.18.1.6.5
Number of engine starts since last service maintenance. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceTotalkWhMaintenance 1.3.6.1.4.1.318.1.1.18.1.6.6
Total kWh of operation since last service maintenance. -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceResetRecord 1.3.6.1.4.1.318.1.1.18.1.6.7
Resets the engine start counter, engine run-hours, and kWh values that have accumulated in the generator since last maintenance. Also, the last service date will be reset to the current system date, and any service alarms will be cleared.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

xATSGeneratorServiceRecordResetDate 1.3.6.1.4.1.318.1.1.18.1.6.8
Date at which the generator's service record was reset, in dd-mmm-yyyy format.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorServiceNextServiceDate 1.3.6.1.4.1.318.1.1.18.1.6.9
Date at which the next generator service is due in dd-mmm-yyyy format. Based on the xATSGeneratorServiceCalendarIntervalThreshold OID or '' if the calendar-based threshold is set to off.
OBJECT-TYPE    
  DisplayString  

xATSGeneratorServiceRunHoursUntilServiceDate 1.3.6.1.4.1.318.1.1.18.1.6.10
Run hours until the next generator service is due, in hours. Based on the xATSGeneratorServiceRunHoursThreshold OID or -1 if the run hour-based threshold is set to off.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorServiceRunHoursThreshold 1.3.6.1.4.1.318.1.1.18.1.6.11
Run hour-based service interval. When the run-hours since service surpasses this threshold, generator service is due.
OBJECT-TYPE    
  INTEGER disabled(1), runThreshold100Hours(2), runThreshold150Hours(3), runThreshold200Hours(4), runThreshold250Hours(5), runThreshold300Hours(6), runThreshold400Hours(7), runThreshold500Hours(8)  

xATSGeneratorServiceCalendarIntervalThreshold 1.3.6.1.4.1.318.1.1.18.1.6.12
Calendar-based service interval. When the next service date, as indicated by the xATSGeneratorServiceNextServiceDate OID is in the past, generator is due for service.
OBJECT-TYPE    
  INTEGER disabled(1), interval1month(2), interval2month(3), interval3month(4), interval6month(5), intervalyearly(6)  

xATSGeneratorFuelSystem 1.3.6.1.4.1.318.1.1.18.1.7
OBJECT IDENTIFIER    

xATSGeneratorFuelSystemType 1.3.6.1.4.1.318.1.1.18.1.7.1
The type of fuel used by the generator.
OBJECT-TYPE    
  INTEGER diesel(1), propane(2), naturalGas(3), unknown(4)  

xATSGeneratorFuelSystemTankSize 1.3.6.1.4.1.318.1.1.18.1.7.2
Size of the generator's fuel tank. Specified in gallons or liters, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorFuelSystemFuelLevel 1.3.6.1.4.1.318.1.1.18.1.7.3
Fuel remaining in the generator tank. Measured in percent of tank fill, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorFuelSystemRuntimePower 1.3.6.1.4.1.318.1.1.18.1.7.4
The power value used in the runtime remaining calculation. Measured in tenths of kW, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorFuelSystemEstimatedRunTime 1.3.6.1.4.1.318.1.1.18.1.7.5
An estimate of available runtime for the generator, based on available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID. Measured in tenths of hours, or -1 if not available.
OBJECT-TYPE    
  INTEGER  

xATSGeneratorFuelSystemLowRunTimeThreshold 1.3.6.1.4.1.318.1.1.18.1.7.6
Threshold below which a low runtime alarm will exist.
OBJECT-TYPE    
  INTEGER disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)  

xATSGeneratorFuelSystemVeryLowRunTimeThreshold 1.3.6.1.4.1.318.1.1.18.1.7.7
Threshold below which a very low runtime alarm will exist.
OBJECT-TYPE    
  INTEGER disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)  

xATSGeneratorFuelSystemLowFuelLevelThreshold 1.3.6.1.4.1.318.1.1.18.1.7.8
Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill.
OBJECT-TYPE    
  INTEGER 0..100  

xATSGeneratorFuelSystemVeryLowFuelLevelThreshold 1.3.6.1.4.1.318.1.1.18.1.7.9
Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill.
OBJECT-TYPE    
  INTEGER 0..100  

consolePortServer 1.3.6.1.4.1.318.1.1.19
OBJECT IDENTIFIER    

cpsAP930x 1.3.6.1.4.1.318.1.1.19.1
OBJECT IDENTIFIER    

cpsAP930xSys 1.3.6.1.4.1.318.1.1.19.1.1
OBJECT IDENTIFIER    

apCPSpname 1.3.6.1.4.1.318.1.1.19.1.1.1
The product's name.
OBJECT-TYPE    
  DisplayString  

apCPSversion 1.3.6.1.4.1.318.1.1.19.1.1.2
The firmware's version.
OBJECT-TYPE    
  DisplayString  

apCPSPower 1.3.6.1.4.1.318.1.1.19.1.1.3
OBJECT IDENTIFIER    

apCPSPwNum 1.3.6.1.4.1.318.1.1.19.1.1.3.1
The number of the power supplies.
OBJECT-TYPE    
  Integer32  

apCPSPw1 1.3.6.1.4.1.318.1.1.19.1.1.3.2
State of the first power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF.
OBJECT-TYPE    
  INTEGER  

apCPSPw2 1.3.6.1.4.1.318.1.1.19.1.1.3.3
State of the second power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF.
OBJECT-TYPE    
  INTEGER  

apCPSPcmcia 1.3.6.1.4.1.318.1.1.19.1.1.4
OBJECT IDENTIFIER    

apCPSNPcmcia 1.3.6.1.4.1.318.1.1.19.1.1.4.1
Number of PCMCIA cards available.
OBJECT-TYPE    
  Integer32  

cpsCardIdentTable 1.3.6.1.4.1.318.1.1.19.1.1.4.2
A table of PCMCIA card identifications.
OBJECT-TYPE    
  SEQUENCE OF  
    CpsCardIdentEntry

cpsCardIdentEntry 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1
Identification information for a PCMCIA card.
OBJECT-TYPE    
  CpsCardIdentEntry  

cpsCardIdentIndex 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.1
Number to identify the socket Card.
OBJECT-TYPE    
  Integer32  

cpsCardIdentProd 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.2
Product identification string.
OBJECT-TYPE    
  DisplayString  

cpsCardIdentMan 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.3
Manufacturer ID code.
OBJECT-TYPE    
  DisplayString  

cpsCardIdentFunc 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.4
Function ID code.
OBJECT-TYPE    
  DisplayString  

cpsCardIdentPCI 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.5
PCI ID
OBJECT-TYPE    
  DisplayString  

cpsCardConfTable 1.3.6.1.4.1.318.1.1.19.1.1.4.3
A table of socket configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    CpsCardConfEntry

cpsCardConfEntry 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1
Configuration information for a socket.
OBJECT-TYPE    
  CpsCardConfEntry  

cpsCardConfIndex 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.1
Number to identify the socket PCMCIA.
OBJECT-TYPE    
  Integer32  

cpsCardConfPower 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.2
Power Settings.
OBJECT-TYPE    
  DisplayString  

cpsCardConfType 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.3
Interface Type.
OBJECT-TYPE    
  DisplayString  

cpsCardConfInter 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.4
Interrupt number.
OBJECT-TYPE    
  DisplayString  

cpsCardConfFunc 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.5
Function.
OBJECT-TYPE    
  DisplayString  

cpsCardConfCardv 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.6
Card values.
OBJECT-TYPE    
  DisplayString  

cpsCardConfPort1 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.7
I/O Port 1.
OBJECT-TYPE    
  DisplayString  

cpsCardConfPort2 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.8
I/O Port 2.
OBJECT-TYPE    
  DisplayString  

cpsCardStatusTable 1.3.6.1.4.1.318.1.1.19.1.1.4.4
A table of current socket status information.
OBJECT-TYPE    
  SEQUENCE OF  
    CpsCardStatusEntry

cpsCardStatusEntry 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1
Current status information for a socket.
OBJECT-TYPE    
  CpsCardStatusEntry  

cpsCardStatusIndex 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.1
Number to identify the socket PCMCIA.
OBJECT-TYPE    
  Integer32 0..2  

cpsCardStatusCard 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.2
Current Card State.
OBJECT-TYPE    
  DisplayString  

cpsCardStatusFunc 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.3
Current Function.
OBJECT-TYPE    
  DisplayString  

apCPSFlashSize 1.3.6.1.4.1.318.1.1.19.1.1.5
Total amount of flash memory in Mbytes.
OBJECT-TYPE    
  Integer32  

apCPSRAMSize 1.3.6.1.4.1.318.1.1.19.1.1.6
Total amount of RAM in Mbytes.
OBJECT-TYPE    
  Integer32  

apCPSCPUfreq 1.3.6.1.4.1.318.1.1.19.1.1.7
CPU clock in MHz.
OBJECT-TYPE    
  Integer32  

apCPSDevId 1.3.6.1.4.1.318.1.1.19.1.1.8
The product's identifier.
OBJECT-TYPE    
  DisplayString  

cpsAP930xConf 1.3.6.1.4.1.318.1.1.19.1.2
OBJECT IDENTIFIER    

cpsHostName 1.3.6.1.4.1.318.1.1.19.1.2.1
The Host Name.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsConsoleBanner 1.3.6.1.4.1.318.1.1.19.1.2.2
The console banner.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

cpsMotd 1.3.6.1.4.1.318.1.1.19.1.2.3
The motd message.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

cpsEthItf 1.3.6.1.4.1.318.1.1.19.1.2.4
OBJECT IDENTIFIER    

cpsEthDhcpc 1.3.6.1.4.1.318.1.1.19.1.2.4.1
0 will indicate DHCP inactive, 1 will indicate DHCP active, 2 will indicate DHCP active and the last parameter is saved.
OBJECT-TYPE    
  INTEGER  

cpsEthIPaddr 1.3.6.1.4.1.318.1.1.19.1.2.4.2
This is the IP address of the Ethernet Interface.
OBJECT-TYPE    
  IpAddress  

cpsEthIPmask 1.3.6.1.4.1.318.1.1.19.1.2.4.3
The mask for the Ethernet network.
OBJECT-TYPE    
  IpAddress  

cpsEthMTU 1.3.6.1.4.1.318.1.1.19.1.2.4.4
The Maximum Transmission Unit size, which determines whether packets should be broken up.
OBJECT-TYPE    
  Integer32  

cpsEthIPaddr2 1.3.6.1.4.1.318.1.1.19.1.2.4.5
The Ethernet secondary IP address.
OBJECT-TYPE    
  IpAddress  

cpsEthIPmask2 1.3.6.1.4.1.318.1.1.19.1.2.4.6
The Ethernet secondary IP mask.
OBJECT-TYPE    
  IpAddress  

cpsNameService 1.3.6.1.4.1.318.1.1.19.1.2.5
OBJECT IDENTIFIER    

cpsResolverOrder 1.3.6.1.4.1.318.1.1.19.1.2.5.1
Specifies how host lookups are to be performed. Valid values : empty, 'hosts', 'bind', 'hosts, bind', 'bind, hosts'
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

cpsMultipleIP 1.3.6.1.4.1.318.1.1.19.1.2.5.2
Valid values are ON or OFF. If set to ON, the resolve library will return all valid addresses for a host that appears in the /etc/hosts file, instead of only the first.
OBJECT-TYPE    
  DisplayString SIZE(0..3)  

cpsDNSserv 1.3.6.1.4.1.318.1.1.19.1.2.5.3
OBJECT IDENTIFIER    

cpsDNSpriserv 1.3.6.1.4.1.318.1.1.19.1.2.5.3.1
Internet Address (in dot notation) of primary name server that the resolver should query.
OBJECT-TYPE    
  IpAddress  

cpsDNSsecserv 1.3.6.1.4.1.318.1.1.19.1.2.5.3.2
Internet Address (in dot notation) of secondary name server that the resolver should query.
OBJECT-TYPE    
  IpAddress  

cpsDNSdomain 1.3.6.1.4.1.318.1.1.19.1.2.5.3.3
Local domain name.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortConf 1.3.6.1.4.1.318.1.1.19.1.2.6
OBJECT IDENTIFIER    

cpsSerialGlobal 1.3.6.1.4.1.318.1.1.19.1.2.6.1
OBJECT IDENTIFIER    

cpsSerialInclude 1.3.6.1.4.1.318.1.1.19.1.2.6.1.1
File used in centralized management.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialNFS 1.3.6.1.4.1.318.1.1.19.1.2.6.1.2
Remote Network File System where data buffering will be written instead of the default directory '/var/run/DB'.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialLockDir 1.3.6.1.4.1.318.1.1.19.1.2.6.1.3
The lock directory.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialRlogin 1.3.6.1.4.1.318.1.1.19.1.2.6.1.4
Location of the rlogin binary that accepts the -i flag.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialPppd 1.3.6.1.4.1.318.1.1.19.1.2.6.1.5
Location of the pppd binary.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialTelnet 1.3.6.1.4.1.318.1.1.19.1.2.6.1.6
Location of the telnet application.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialSsh 1.3.6.1.4.1.318.1.1.19.1.2.6.1.7
Location of the ssh application.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

cpsSerialLocalLogins 1.3.6.1.4.1.318.1.1.19.1.2.6.1.8
This parameter is only necessary when authentication is being performed for a port. This is useful if the Radius authentication server is down. 0 indicates OFF, 1 indicates ON.
OBJECT-TYPE    
  INTEGER  

cpsSerialFacility 1.3.6.1.4.1.318.1.1.19.1.2.6.1.9
This value (0-7) is the Local facility sent to the syslog daemon.
OBJECT-TYPE    
  Integer32  

cpsSerialDBFacility 1.3.6.1.4.1.318.1.1.19.1.2.6.1.10
This value (0-7) is the Local facility sent to the syslog daemon.
OBJECT-TYPE    
  Integer32  

cpsSerialGroupTable 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11
OBJECT-TYPE    
  SEQUENCE OF  
    CpsSerialGroupEntry

cpsSerialGroupEntry 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1
OBJECT-TYPE    
  CpsSerialGroupEntry  

cpsSerialGroupIndex 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.1
Number to identify the group.
OBJECT-TYPE    
  INTEGER  

cpsSerialGroupName 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.2
The group name.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

cpsSerialGroupUsers 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.3
The user's names.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

cpsSerialSpec 1.3.6.1.4.1.318.1.1.19.1.2.6.2
OBJECT IDENTIFIER    

cpsSerialPortTable 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1
This is the specific configuration per serial port.
OBJECT-TYPE    
  SEQUENCE OF  
    CpsSerialPortEntry

cpsSerialPortEntry 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1
One particular serial port configuration.
OBJECT-TYPE    
  CpsSerialPortEntry  

cpsSerialPortNumber 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.1
Number to identify the serial port. Value 0 is ALL.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortTty 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.2
The device name for the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

cpsSerialPortName 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.3
Alias name given to the server connected to the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortSpeed 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.4
The speed of the serial port. Supported values are: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400, and 460800
OBJECT-TYPE    
  Integer32  

cpsSerialPortDataSize 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.5
The data size for the serial port.
OBJECT-TYPE    
  Integer32 4..8  

cpsSerialPortStopBits 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.6
The number of stop bits for the serial port.
OBJECT-TYPE    
  Integer32 0..2  

cpsSerialPortParity 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.7
The parity for the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cpsSerialPortFlowCtrl 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.8
The flow control for the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cpsSerialPortDTRdelay 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.9
This specifies how long (in milliseconds) a DTR signal will be turned off before it is turned on again.
OBJECT-TYPE    
  Integer32  

cpsSerialPortDCDCtrl 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.10
DCD signal controls the connection request. 0 will indicate nocontrol, 1 will indicate control.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortLogUtmp 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.11
Update the login records in /var/run/utmp file. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortLogWtmp 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.12
Update the login records in /var/run/wtmp file. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortLogform 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.13
This is the format to write the login record.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortAuthtype 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.14
Authentication type.
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

cpsSerialPortAuthSrv1 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.15
IP address of the primary authentication server.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortAccSrv1 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.16
IP address of the primary accounting server.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortAuthTmo 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.17
This is the timeout (in seconds) for the authentication query to be answered.
OBJECT-TYPE    
  Integer32  

cpsSerialPortAuthRetr 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.18
This defines the number of times each server is tried before another is contacted.
OBJECT-TYPE    
  Integer32  

cpsSerialPortAuthSrv2 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.19
IP address of the secondary authentication server.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortAccSrv2 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.20
IP address of the secondary accounting server.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortAuthSecret 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.21
This is the shared secret with authentication servers.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortAuthRadP 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.22
Radius state. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortAuthAcc 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.23
Access restriction.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortProtocol 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.24
Defines the serial port's protocol.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortRemoteIP 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.25
This is the default IP address of the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

cpsSerialPortSocketPort 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.26
This defines an alternative labeling system for the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cpsSerialPortRemHost 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.27
The IP address of the host to which the serial port will connect.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortBanner 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.28
This defines the banner.
OBJECT-TYPE    
  DisplayString SIZE(0..250)  

cpsSerialPortPrompt 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.29
This defines the login prompt to the serial port.
OBJECT-TYPE    
  DisplayString SIZE(0..250)  

cpsSerialPortTermType 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.30
This defines the terminal type.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

cpsSerialPortAutomUsr 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.31
This defines the automatic user.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortNetMask 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.32
The network mask used in dial in connection.
OBJECT-TYPE    
  IpAddress  

cpsSerialPortPppMtu 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.33
The PPP MTU - dial in connection.
OBJECT-TYPE    
  Integer32  

cpsSerialPortPppMru 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.34
The PPP MRU - dial in connection.
OBJECT-TYPE    
  Integer32  

cpsSerialPortPppOptions 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.35
The PPP options when the PPP session is autodetected.
OBJECT-TYPE    
  DisplayString  

cpsSerialPortPppFoption 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.36
The PPP forced options when the user has already been authenticated.
OBJECT-TYPE    
  DisplayString  

cpsSerialPortModemChat 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.37
The initchat send to modem connected.
OBJECT-TYPE    
  DisplayString  

cpsSerialPortSttyCmd 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.38
The tty settings after socket connection is established.
OBJECT-TYPE    
  DisplayString SIZE(0..180)  

cpsSerialPortSockTx 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.39
Defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port.
OBJECT-TYPE    
  Integer32  

cpsSerialPortSockPoll 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.40
Keep-alive timer (milliseconds) for the TCP connection.
OBJECT-TYPE    
  Integer32  

cpsSerialPortSockIdle 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.41
The idle timeout in seconds.
OBJECT-TYPE    
  Integer32  

cpsSerialPortDBsize 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.42
Maximum size of the data buffering file.
OBJECT-TYPE    
  Integer32  

cpsSerialPortDBtime 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.43
Timestamp in data buffering. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortDBmode 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.44
Data buffering mode : circ or line.
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cpsSerialPortDBsyslog 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.45
Size of the data buffer sent to syslog.
OBJECT-TYPE    
  Integer32  

cpsSerialPortDBmenu 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.46
Menu type for data buffering. 0 will indicate display Menu, 1 will indicate inactive, 2 will indicate DB, 3 will indicate Parc.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortDBalarm 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.47
Alarm generation status. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortSSHbreak 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.48
Break sequence - ssh session.
OBJECT-TYPE    
  DisplayString SIZE(0..16)  

cpsSerialPortSniffSess 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.49
Sniff session type.
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cpsSerialPortSniffAdm 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.50
List of admin users allowed to sniff session.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortSniffEsc 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.51
Escape sequence used in sniff session.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

cpsSerialPortSniffMsess 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.52
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

cpsSerialPortTelnetMode 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.53
Mode negotiated by client telnet with the server. 0 will indicate text, 1 will indicate binary.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortSysBufSess 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.54
Syslog Buffering at all times. 0 will indicate yes, 1 will indicate no.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortLFSuppress 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.55
LF suppression in socket_server session. 0 will indicate inactive, 1 will indicate active.
OBJECT-TYPE    
  INTEGER  

cpsSerialPortAutoInput 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.56
Input string used for auto answer.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortAutoOutput 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.57
Output string used for auto answer.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

cpsSerialPortBreakInterval 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.58
The break interval in milliseconds.
OBJECT-TYPE    
  Integer32  

cpsAP930xInfo 1.3.6.1.4.1.318.1.1.19.1.3
OBJECT IDENTIFIER    

cpsInfoSerialPortTable 1.3.6.1.4.1.318.1.1.19.1.3.1
This is the information of the specific serial port.
OBJECT-TYPE    
  SEQUENCE OF  
    CpsInfoSerialPortEntry

cpsInfoSerialPortEntry 1.3.6.1.4.1.318.1.1.19.1.3.1.1
One particular serial port.
OBJECT-TYPE    
  CpsInfoSerialPortEntry  

cpsInfoSerialPortNumber 1.3.6.1.4.1.318.1.1.19.1.3.1.1.1
Number to identify the serial port.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortTty 1.3.6.1.4.1.318.1.1.19.1.3.1.1.2
The device name for the serial port.
OBJECT-TYPE    
  DisplayString  

cpsInfoSerialPortName 1.3.6.1.4.1.318.1.1.19.1.3.1.1.3
Alias name given to the server connected to the serial port.
OBJECT-TYPE    
  DisplayString  

cpsInfoSerialPortSpeed 1.3.6.1.4.1.318.1.1.19.1.3.1.1.4
The speed for serial port.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortTxBytes 1.3.6.1.4.1.318.1.1.19.1.3.1.1.5
The number of transmitted bytes by the serial port.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortRXBytes 1.3.6.1.4.1.318.1.1.19.1.3.1.1.6
The number of received bytes by the serial port.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortErrFrame 1.3.6.1.4.1.318.1.1.19.1.3.1.1.7
The number of frame errors.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortErrParity 1.3.6.1.4.1.318.1.1.19.1.3.1.1.8
The number of parity errors.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortErrBreaks 1.3.6.1.4.1.318.1.1.19.1.3.1.1.9
The number of breaks errors.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortErrOverrun 1.3.6.1.4.1.318.1.1.19.1.3.1.1.10
The number of overrun errors.
OBJECT-TYPE    
  Integer32  

cpsInfoSerialPortSigDTR 1.3.6.1.4.1.318.1.1.19.1.3.1.1.11
The state of the DTR signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortSigCD 1.3.6.1.4.1.318.1.1.19.1.3.1.1.12
The state of the DCD signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortSigDSR 1.3.6.1.4.1.318.1.1.19.1.3.1.1.13
The state of the DSR signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortSigRTS 1.3.6.1.4.1.318.1.1.19.1.3.1.1.14
The state of the RTS signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortSigCTS 1.3.6.1.4.1.318.1.1.19.1.3.1.1.15
The state of the CTS signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsInfoSerialPortSigRI 1.3.6.1.4.1.318.1.1.19.1.3.1.1.16
The state of the RI signal. 0 will indicate down, 1 will indicate up.
OBJECT-TYPE    
  INTEGER  

cpsAP930xAdm 1.3.6.1.4.1.318.1.1.19.1.4
OBJECT IDENTIFIER    

apCPSSave 1.3.6.1.4.1.318.1.1.19.1.4.1
Exec saveconf command. 0 will indicate don't save, 1 will indicate save.
OBJECT-TYPE    
  INTEGER  

apCPSSerialHUP 1.3.6.1.4.1.318.1.1.19.1.4.2
Exec signal_ras hup command. 0 will indicate no restart, 1 will indicate restart.
OBJECT-TYPE    
  INTEGER  

accessControl 1.3.6.1.4.1.318.1.1.20
OBJECT IDENTIFIER    

accessPX 1.3.6.1.4.1.318.1.1.20.1
OBJECT IDENTIFIER    

accessPXIdent 1.3.6.1.4.1.318.1.1.20.1.1
OBJECT IDENTIFIER    

accessPXIdentAlarmStatus 1.3.6.1.4.1.318.1.1.20.1.1.1
Access PX alarm status 1 = Normal 2 = Warning 3 = Critical.
OBJECT-TYPE    
  INTEGER  

accessPXIdentProductNumber 1.3.6.1.4.1.318.1.1.20.1.1.2
The product number of the Access PX.
OBJECT-TYPE    
  DisplayString  

accessPXIdentHardwareRev 1.3.6.1.4.1.318.1.1.20.1.1.3
The hardware revision number of the Access PX.
OBJECT-TYPE    
  DisplayString  

accessPXIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.20.1.1.4
The date of manufacture of the Access PX.
OBJECT-TYPE    
  DisplayString  

accessPXIdentSerialNumber 1.3.6.1.4.1.318.1.1.20.1.1.5
The serial number of the Access PX.
OBJECT-TYPE    
  DisplayString  

accessPXConfig 1.3.6.1.4.1.318.1.1.20.1.2
OBJECT IDENTIFIER    

accessPXConfigCardReaderEnableDisableAction 1.3.6.1.4.1.318.1.1.20.1.2.1
Action to disable/enable the card reader.
OBJECT-TYPE    
  INTEGER disabled(1), enable(2)  

accessPXConfigAutoRelockTime 1.3.6.1.4.1.318.1.1.20.1.2.2
Time (10 - 60) in seconds when the door will automatically relock after it has been unlocked and the handle has not been opened.
OBJECT-TYPE    
  INTEGER  

accessPXConfigCardFormat 1.3.6.1.4.1.318.1.1.20.1.2.3
Indicates and controls the HID card format. NOTE: This OID is only valid for HID systems.
OBJECT-TYPE    
  INTEGER hidStd26(1), hid37Bit(2), hid37BitWithFacility(3), hidCorp1000(4)  

accessPXConfigFront 1.3.6.1.4.1.318.1.1.20.1.3
OBJECT IDENTIFIER    

accessPXConfigFrontDoorLockControl 1.3.6.1.4.1.318.1.1.20.1.3.1
Control action (unlock, lock) for the front door. Setting this OID will unlock or lock the front door. Getting this OID will respond with the current state of the front door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected.
OBJECT-TYPE    
  INTEGER unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)  

accessPXConfigFrontDoorMaxOpenTime 1.3.6.1.4.1.318.1.1.20.1.3.2
Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition.
OBJECT-TYPE    
  INTEGER  

accessPXStatusFront 1.3.6.1.4.1.318.1.1.20.1.4
OBJECT IDENTIFIER    

accessPXStatusFrontDoorLock 1.3.6.1.4.1.318.1.1.20.1.4.1
Present state of the front door lock: unlocked, locked, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER unlocked(1), locked(2), notInstalled(3), disconnected(4)  

accessPXStatusFrontDoor 1.3.6.1.4.1.318.1.1.20.1.4.2
Present state of the front door: open, closed, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER open(1), closed(2), notInstalled(3), disconnected(4)  

accessPXStatusFrontDoorHandle 1.3.6.1.4.1.318.1.1.20.1.4.3
Present state of the front door handle: open, closed, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER open(1), closed(2), notInstalled(3), disconnected(4)  

accessPXStatusFrontDoorMaxOpenTime 1.3.6.1.4.1.318.1.1.20.1.4.4
Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition.
OBJECT-TYPE    
  INTEGER  

accessPXStatusFrontDoorAlarmStatus 1.3.6.1.4.1.318.1.1.20.1.4.5
Front door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Front door not installed.
OBJECT-TYPE    
  INTEGER  

accessPXConfigRear 1.3.6.1.4.1.318.1.1.20.1.5
OBJECT IDENTIFIER    

accessPXConfigRearDoorLockControl 1.3.6.1.4.1.318.1.1.20.1.5.1
Control action (unlock, lock) for the rear door. Setting this OID will unlock or lock the rear door. Getting this OID will respond with the current state of the rear door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected.
OBJECT-TYPE    
  INTEGER unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)  

accessPXConfigRearDoorMaxOpenTime 1.3.6.1.4.1.318.1.1.20.1.5.2
Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition.
OBJECT-TYPE    
  INTEGER  

accessPXStatusRear 1.3.6.1.4.1.318.1.1.20.1.6
OBJECT IDENTIFIER    

accessPXStatusRearDoorLock 1.3.6.1.4.1.318.1.1.20.1.6.1
Present state of the rear door lock: unlocked, locked, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER unlocked(1), locked(2), notInstalled(3), disconnected(4)  

accessPXStatusRearDoor 1.3.6.1.4.1.318.1.1.20.1.6.2
Present state of the rear door: open, closed, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER open(1), closed(2), notInstalled(3), disconnected(4)  

accessPXStatusRearDoorHandle 1.3.6.1.4.1.318.1.1.20.1.6.3
Present state of the rear door handle: open, closed, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER open(1), closed(2), notInstalled(3), disconnected(4)  

accessPXStatusRearDoorMaxOpenTime 1.3.6.1.4.1.318.1.1.20.1.6.4
Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition.
OBJECT-TYPE    
  INTEGER  

accessPXStatusRearDoorAlarmStatus 1.3.6.1.4.1.318.1.1.20.1.6.5
Rear door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Rear door not installed.
OBJECT-TYPE    
  INTEGER  

accessPXConfigBeacon 1.3.6.1.4.1.318.1.1.20.1.7
OBJECT IDENTIFIER    

accessPXConfigBeaconName 1.3.6.1.4.1.318.1.1.20.1.7.1
A descriptive name for the Beacon.
OBJECT-TYPE    
  DisplayString  

accessPXConfigBeaconLocation 1.3.6.1.4.1.318.1.1.20.1.7.2
A descriptive name for the location of the Beacon.
OBJECT-TYPE    
  DisplayString  

accessPXConfigBeaconAction 1.3.6.1.4.1.318.1.1.20.1.7.3
Control action (turnOff, turnOn) for the beacon. Setting this OID will turn the beacon off or on. Getting this OID will respond with the current state which could be 1 = off, 2 = on, 3 = not installed, 4 = disconnected.
OBJECT-TYPE    
  INTEGER turnOff(1), turnOn(2), notInstalledReadOnly(3), disconnectedReadOnly(4)  

accessPXStatusBeacon 1.3.6.1.4.1.318.1.1.20.1.8
OBJECT IDENTIFIER    

accessPXStatusBeaconName 1.3.6.1.4.1.318.1.1.20.1.8.1
The name of the beacon.
OBJECT-TYPE    
  DisplayString  

accessPXStatusBeaconLocation 1.3.6.1.4.1.318.1.1.20.1.8.2
The name of the location of the beacon.
OBJECT-TYPE    
  DisplayString  

accessPXStatusBeaconCurrentState 1.3.6.1.4.1.318.1.1.20.1.8.3
The current state of the beacon: off, on, not installed, or disconnected.
OBJECT-TYPE    
  INTEGER off(1), on(2), notInstalled(3), disconnected(4)  

apcLocalDisplay 1.3.6.1.4.1.318.1.1.21
OBJECT IDENTIFIER    

apcLocalDisplayIdent 1.3.6.1.4.1.318.1.1.21.1
OBJECT IDENTIFIER    

apcLocalDisplayIdentDisplayType 1.3.6.1.4.1.318.1.1.21.1.1
Numeric value used to identify the type of display in use.
OBJECT-TYPE    
  INTEGER noDisplayFound(1), powerviewRM(2), powerviewWW(3)  

apcLocalDisplayIdentModelNumber 1.3.6.1.4.1.318.1.1.21.1.2
The model number of the local display.
OBJECT-TYPE    
  DisplayString  

apcLocalDisplayIdentFirmwareRev 1.3.6.1.4.1.318.1.1.21.1.3
The firmware revision number of the local display.
OBJECT-TYPE    
  DisplayString  

apcLocalDisplayIdentOptions 1.3.6.1.4.1.318.1.1.21.1.4
A display-specific string identifying options in the local display.
OBJECT-TYPE    
  DisplayString  

apcLocalDisplayIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.21.1.5
The date of manufacture of the local display, if available.
OBJECT-TYPE    
  DisplayString  

apcLocalDisplayIdentSerialNumber 1.3.6.1.4.1.318.1.1.21.1.6
The serial number of the local display, if available.
OBJECT-TYPE    
  DisplayString  

apcLocalDisplayConfig 1.3.6.1.4.1.318.1.1.21.2
OBJECT IDENTIFIER    

apcLocalDisplayConfigAlarmBeeper 1.3.6.1.4.1.318.1.1.21.2.1
The alarm beeper setting for the local display. When enabled, the alarm beeper will begin to sound whenever there a new alarm becomes active. The alarm beeper will continue to periodically sound until a key is pressed on the display.
OBJECT-TYPE    
  INTEGER beeperDisabled(1), beeperEnabled(2)  

apcLocalDisplayConfigBeeperVolume 1.3.6.1.4.1.318.1.1.21.2.2
The volume setting of the beeper on the local display.
OBJECT-TYPE    
  INTEGER beeperDisabled(1), beeperLow(2), beeperMedium(3), beeperHigh(4)  

apcLocalDisplayConfigCheckLogIndicator 1.3.6.1.4.1.318.1.1.21.2.3
The minimum level event severity level required to illuminate the check log light on the local display. notPresent (1) indicates that the display does not have a check log light.
OBJECT-TYPE    
  INTEGER checklogNotPresent(1), checklogDisabled(2), checklogInformational(3), checklogWarning(4), checklogCritical(5)  

apcLocalDisplayConfigKeyClick 1.3.6.1.4.1.318.1.1.21.2.4
The key click setting of the local display.
OBJECT-TYPE    
  INTEGER keyclickDisabled(1), keyclickEnabled(2)  

apcLocalDisplayConfigContrast 1.3.6.1.4.1.318.1.1.21.2.5
The contrast level of the local display.
OBJECT-TYPE    
  INTEGER contrast1(1), contrast2(2), contrast3(3), contrast4(4), contrast5(5), contrast6(6), contrast7(7), contrast8(8)  

isxModularDistribution 1.3.6.1.4.1.318.1.1.22
OBJECT IDENTIFIER    

isxModularDistInfo 1.3.6.1.4.1.318.1.1.22.1
OBJECT IDENTIFIER    

isxModularDistInfoTableSize 1.3.6.1.4.1.318.1.1.22.1.1
The number of entries in the isxModularDistInfoTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistInfoTable 1.3.6.1.4.1.318.1.1.22.1.2
Allows for getting information about the modular distribution metering equipment.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistInfoEntry

isxModularDistInfoEntry 1.3.6.1.4.1.318.1.1.22.1.2.1
An entry containing information about an individual metering segment.
OBJECT-TYPE    
  IsxModularDistInfoEntry  

isxModularDistInfoSegmentIndex 1.3.6.1.4.1.318.1.1.22.1.2.1.1
The index of the metering segment.
OBJECT-TYPE    
  INTEGER  

isxModularDistInfoMeterModelNumber 1.3.6.1.4.1.318.1.1.22.1.2.1.2
The model number of the metering board for this segment.
OBJECT-TYPE    
  DisplayString  

isxModularDistInfoMeterSerialNumber 1.3.6.1.4.1.318.1.1.22.1.2.1.3
The serial number of the metering board for this segment.
OBJECT-TYPE    
  DisplayString  

isxModularDistInfoMeterDateOfManufacture 1.3.6.1.4.1.318.1.1.22.1.2.1.4
The date of manufacture for the metering board for this segment, in the format mm/dd/yyyy.
OBJECT-TYPE    
  DisplayString  

isxModularDistInfoMeterFirmwareRev 1.3.6.1.4.1.318.1.1.22.1.2.1.5
The firmware revision number of the metering board for this segment.
OBJECT-TYPE    
  DisplayString  

isxModularDistInfoMeterHardwareRev 1.3.6.1.4.1.318.1.1.22.1.2.1.6
The hardware revision number of the metering board for this segment.
OBJECT-TYPE    
  DisplayString  

isxModularDistModules 1.3.6.1.4.1.318.1.1.22.2
OBJECT IDENTIFIER    

isxModularDistModuleInfoTableSize 1.3.6.1.4.1.318.1.1.22.2.1
The number of entries in the isxModularDistModuleInfoTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleInfoTable 1.3.6.1.4.1.318.1.1.22.2.2
Allows for getting basic information about the distribution modules installed in the system.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistModuleInfoEntry

isxModularDistModuleInfoEntry 1.3.6.1.4.1.318.1.1.22.2.2.1
An entry containing information about a specific distribution module.
OBJECT-TYPE    
  IsxModularDistModuleInfoEntry  

isxModularDistModuleInfoModIndex 1.3.6.1.4.1.318.1.1.22.2.2.1.1
The number of the distribution module.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleInfoAlarmStatus 1.3.6.1.4.1.318.1.1.22.2.2.1.2
The status of this module. This reflects the indicator lamp(s) on the front of the module. A value of notPresent indicates that the module is not installed. A value of unknown indicates that there is no communication with the metering segment for this module.
OBJECT-TYPE    
  INTEGER normal(1), warning(2), critical(3), notPresent(4), unknown(5)  

isxModularDistModuleInfoModelNumber 1.3.6.1.4.1.318.1.1.22.2.2.1.3
The model number of the distribution module.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleInfoSerialNumber 1.3.6.1.4.1.318.1.1.22.2.2.1.4
The serial number of the distribution module.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleInfoDateOfManufacture 1.3.6.1.4.1.318.1.1.22.2.2.1.5
The date that the distribution module was manufactured.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleInfoNumCables 1.3.6.1.4.1.318.1.1.22.2.2.1.6
The number of cables provided by this distribution module.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerTableSize 1.3.6.1.4.1.318.1.1.22.2.3
The number of entries in the isxModularDistModuleBreakerTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerTable 1.3.6.1.4.1.318.1.1.22.2.4
Allows for getting operational information about the distribution modules.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistModuleBreakerEntry

isxModularDistModuleBreakerEntry 1.3.6.1.4.1.318.1.1.22.2.4.1
An entry containing information about a specific distribution modules and circuit breakers.
OBJECT-TYPE    
  IsxModularDistModuleBreakerEntry  

isxModularDistModuleBreakerModIndex 1.3.6.1.4.1.318.1.1.22.2.4.1.1
The distribution module number.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerPhaseIndex 1.3.6.1.4.1.318.1.1.22.2.4.1.2
The index to an individual breaker in the distribution module. The index also corresponds to the system phase to which the breaker is attached.
OBJECT-TYPE    
  INTEGER phaseL1(1), phaseL2(2), phaseL3(3)  

isxModularDistModuleBreakerAlarmStatus 1.3.6.1.4.1.318.1.1.22.2.4.1.3
This is a bit map representing the active alarms for this breaker: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerRating 1.3.6.1.4.1.318.1.1.22.2.4.1.4
The current rating of the breaker.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerPhysicalGroup 1.3.6.1.4.1.318.1.1.22.2.4.1.5
Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of 1 indicates breakers that are physically tied together as part of a multi-pole breaker. A value of 0 indicates a single-handle breaker that is not physically tied to another breaker.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerCableNum 1.3.6.1.4.1.318.1.1.22.2.4.1.6
Numeric value used to indicate the distribution cable to which this breaker is connected. These distribution cables are described in the table isxModularDistModuleOutputTable, and indexed by the OID isxModularDistModuleOutputCordIndex.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerPosition 1.3.6.1.4.1.318.1.1.22.2.4.1.7
The physical status of this breaker pole, either closed or open (including tripped).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

isxModularDistModuleBreakerPositionAlarms 1.3.6.1.4.1.318.1.1.22.2.4.1.8
Enable or disable breaker position alarms for this circuit breaker.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleBreakerCurrent 1.3.6.1.4.1.318.1.1.22.2.4.1.9
The current flowing though this breaker. Measured in tenths of amps.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerPercent 1.3.6.1.4.1.318.1.1.22.2.4.1.10
The loading on this breaker as a percentage of the breaker's current rating. Expressed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleBreakerPower 1.3.6.1.4.1.318.1.1.22.2.4.1.11
The power being supplied through this breaker. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputsTableSize 1.3.6.1.4.1.318.1.1.22.2.5
The number of entries in the isxModularDistModuleOutputTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputTable 1.3.6.1.4.1.318.1.1.22.2.6
Allows for getting and setting information related to the load equipment being fed by the distribution modules in the ISX Modular Distribution System.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistModuleOutputEntry

isxModularDistModuleOutputEntry 1.3.6.1.4.1.318.1.1.22.2.6.1
An entry containing information about a specific distribution module and its output distribution cables.
OBJECT-TYPE    
  IsxModularDistModuleOutputEntry  

isxModularDistModuleOutputModIndex 1.3.6.1.4.1.318.1.1.22.2.6.1.1
The number of the distribution module supplying power to the load equipment.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputNumCables 1.3.6.1.4.1.318.1.1.22.2.6.1.2
The number of distribution cables provided by this module.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputCordIndex 1.3.6.1.4.1.318.1.1.22.2.6.1.3
The index of an individual distribution cable supplied by this module.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputName 1.3.6.1.4.1.318.1.1.22.2.6.1.4
A string describing the load equipment being supplied by this distribution cable.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleOutputLocation 1.3.6.1.4.1.318.1.1.22.2.6.1.5
A string describing the location of equipment being supplied by distribution cable.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleOutputStatus 1.3.6.1.4.1.318.1.1.22.2.6.1.6
This reflects the worse case severity for alarms associated with this distribution cable. A value of notPresent indicates that the cable does not exist for this module. A value of unknown indicates that the there is no communication with the metering segment for this distribution cable's module.
OBJECT-TYPE    
  INTEGER normal(1), warning(2), critical(3), notPresent(4), unknown(6)  

isxModularDistModuleOutputAlarmGeneration 1.3.6.1.4.1.318.1.1.22.2.6.1.7
Enable or disable all alarm generation related to this distribution cable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleOutputBreakerMap 1.3.6.1.4.1.318.1.1.22.2.6.1.8
This is a bit map representing the breaker poles within the module that are associated with this distribution cable. The following 3 bits are used to indicate the indices of the breakers feeding the cable: b0 - Module breaker L1 b1 - Module breaker L2 b2 - Module breaker L3 If a bit is set, the breaker is used to feed this distribution cable. These breakers are described in the table isxModularDistModuleBreakerTable, and indexed by the OID isxModularDistModuleBreakerPhaseIndex.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputThresholdMin 1.3.6.1.4.1.318.1.1.22.2.6.1.9
When the current drops below this value a critical alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputThresholdLow 1.3.6.1.4.1.318.1.1.22.2.6.1.10
When the current drops below this value a warning alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputThresholdHigh 1.3.6.1.4.1.318.1.1.22.2.6.1.11
When the current exceeds this value a warning alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputThresholdMax 1.3.6.1.4.1.318.1.1.22.2.6.1.12
When the current exceeds this value a critical alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputAlarmMinEnable 1.3.6.1.4.1.318.1.1.22.2.6.1.13
Enable or disable minimum current alarm generation for this distribution cable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleOutputAlarmLowEnable 1.3.6.1.4.1.318.1.1.22.2.6.1.14
Enable or disable low current alarm generation for this distribution cable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleOutputAlarmHighEnable 1.3.6.1.4.1.318.1.1.22.2.6.1.15
Enable or disable high current alarm generation for this distribution cable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleOutputAlarmMaxEnable 1.3.6.1.4.1.318.1.1.22.2.6.1.16
Enable or disable maximum current alarm generation for this distribution cable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistModuleOutputCableLength 1.3.6.1.4.1.318.1.1.22.2.6.1.17
The length of this distribution cable. Specified in tenths of meters.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputConnectorType 1.3.6.1.4.1.318.1.1.22.2.6.1.18
A string describing the connector on the end of this distribution cable.
OBJECT-TYPE    
  DisplayString  

isxModularDistModuleOutputAvailableVoltages 1.3.6.1.4.1.318.1.1.22.2.6.1.19
This is a bit map representing the voltages that are available at the connector. 6 bits are used to indicate the following: b0 - L1 b1 - L2 b2 - L3 b3 - L1-2 b4 - L2-3 b5 - L3-1
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputTotalPower 1.3.6.1.4.1.318.1.1.22.2.6.1.20
The total power being consumed by the load equipment supplied by this distribution cable. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputKwhUsage 1.3.6.1.4.1.318.1.1.22.2.6.1.21
The total energy consumed by the load equipment fed by this distribution cable. This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate OID, and may be cleared using the isxModularDistModuleOutputKwhReset OID. Measured in tenths of kWh.
OBJECT-TYPE    
  INTEGER  

isxModularDistModuleOutputKwhReset 1.3.6.1.4.1.318.1.1.22.2.6.1.22
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistModuleOutputKwhUsage OID.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

isxModularDistModuleOutputKwhResetDate 1.3.6.1.4.1.318.1.1.22.2.6.1.23
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
OBJECT-TYPE    
  DisplayString  

isxModularDistSubFeeds 1.3.6.1.4.1.318.1.1.22.3
OBJECT IDENTIFIER    

isxModularDistSubFeedInfoTableSize 1.3.6.1.4.1.318.1.1.22.3.1
The number of entries in the isxModularDistSubFeedInfoTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoTable 1.3.6.1.4.1.318.1.1.22.3.2
Allows for getting information about distribution subfeed breakers.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistSubFeedInfoEntry

isxModularDistSubFeedInfoEntry 1.3.6.1.4.1.318.1.1.22.3.2.1
An entry containing information about a specific distribution subfeed.
OBJECT-TYPE    
  IsxModularDistSubFeedInfoEntry  

isxModularDistSubFeedInfoSubIndex 1.3.6.1.4.1.318.1.1.22.3.2.1.1
The index of an individual subfeed.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoName 1.3.6.1.4.1.318.1.1.22.3.2.1.2
A string describing the load equipment being supplied by this subfeed.
OBJECT-TYPE    
  DisplayString  

isxModularDistSubFeedInfoLocation 1.3.6.1.4.1.318.1.1.22.3.2.1.3
A string describing the location of the equipment being supplied by this subfeed.
OBJECT-TYPE    
  DisplayString  

isxModularDistSubFeedInfoBreakerRating 1.3.6.1.4.1.318.1.1.22.3.2.1.4
The current rating of this subfeed breaker.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoBreakerPosition 1.3.6.1.4.1.318.1.1.22.3.2.1.5
The operational status of this breaker, either closed or open (including tripped).
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

isxModularDistSubFeedInfoAlarmStatus 1.3.6.1.4.1.318.1.1.22.3.2.1.6
The worst case alarm status for this subfeed.
OBJECT-TYPE    
  INTEGER normal(1), warning(2), critical(3)  

isxModularDistSubFeedInfoAlarmGeneration 1.3.6.1.4.1.318.1.1.22.3.2.1.7
Enable or disable all alarm generation related to this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoThresholdMin 1.3.6.1.4.1.318.1.1.22.3.2.1.8
When the current drops below this value a critical alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoThresholdLow 1.3.6.1.4.1.318.1.1.22.3.2.1.9
When the current drops below this value a warning alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoThresholdHigh 1.3.6.1.4.1.318.1.1.22.3.2.1.10
When the current exceeds this value a warning alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoThresholdMax 1.3.6.1.4.1.318.1.1.22.3.2.1.11
When the current exceeds this value a critical alarm will exist.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoAlarmMinEnable 1.3.6.1.4.1.318.1.1.22.3.2.1.12
Enable or disable minimum current alarm generation for this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoAlarmLowEnable 1.3.6.1.4.1.318.1.1.22.3.2.1.13
Enable or disable low current alarm generation for this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoAlarmHighEnable 1.3.6.1.4.1.318.1.1.22.3.2.1.14
Enable or disable high current alarm generation for this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoAlarmMaxEnable 1.3.6.1.4.1.318.1.1.22.3.2.1.15
Enable or disable maximum current alarm generation for this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoBreakerAlarmEnable 1.3.6.1.4.1.318.1.1.22.3.2.1.16
Enable or disable breaker position alarms for this subfeed.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSubFeedInfoTotalPower 1.3.6.1.4.1.318.1.1.22.3.2.1.17
The total power being supplied by this subfeed. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoKwhUsage 1.3.6.1.4.1.318.1.1.22.3.2.1.18
The total energy consumed by the load equipment fed by this subfeed. This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate OID, and may be cleared using the isxModularDistSubFeedInfoKwhReset OID. Measured in tenths of kWh.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedInfoKwhReset 1.3.6.1.4.1.318.1.1.22.3.2.1.19
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSubFeedInfoKwhUsage OID.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

isxModularDistSubFeedInfoKwhResetDate 1.3.6.1.4.1.318.1.1.22.3.2.1.20
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
OBJECT-TYPE    
  DisplayString  

isxModularDistSubFeedLoadingTableSize 1.3.6.1.4.1.318.1.1.22.3.3
The number of entries in the isxModularDistSubFeedLoadingTable.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedLoadingTable 1.3.6.1.4.1.318.1.1.22.3.4
Allows for getting subfeed phase loading information.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistSubFeedLoadingEntry

isxModularDistSubFeedLoadingEntry 1.3.6.1.4.1.318.1.1.22.3.4.1
An entry containing data for an individual subfeed.
OBJECT-TYPE    
  IsxModularDistSubFeedLoadingEntry  

isxModularDistSubFeedLoadingSubIndex 1.3.6.1.4.1.318.1.1.22.3.4.1.1
The index of an individual subfeed.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedLoadingPhaseIndex 1.3.6.1.4.1.318.1.1.22.3.4.1.2
Description of each input phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

isxModularDistSubFeedLoadingAlarmStatus 1.3.6.1.4.1.318.1.1.22.3.4.1.3
This is a bit map representing the active alarms for this subfeed: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedLoadingCurrent 1.3.6.1.4.1.318.1.1.22.3.4.1.4
The current flowing though this subfeed phase. Measured in tenths of amps.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedLoadingPercent 1.3.6.1.4.1.318.1.1.22.3.4.1.5
The loading on this subfeed phase as a percentage of the subfeed's current rating. Expressed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

isxModularDistSubFeedLoadingPower 1.3.6.1.4.1.318.1.1.22.3.4.1.6
The power being supplied by this subfeed phase. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistTotals 1.3.6.1.4.1.318.1.1.22.4
OBJECT IDENTIFIER    

isxModularDistSysVoltage 1.3.6.1.4.1.318.1.1.22.4.1
OBJECT IDENTIFIER    

isxModularDistSysOutputVoltageNominalLineToNeutral 1.3.6.1.4.1.318.1.1.22.4.1.1
The nominal line-to-neutral voltage available at the distribution panel.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageNominalLineToLine 1.3.6.1.4.1.318.1.1.22.4.1.2
The nominal line-to-line voltage available at the distribution panel.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputNominalFrequency 1.3.6.1.4.1.318.1.1.22.4.1.3
The nominal system output frequency. Measured in tenths of Hertz.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputFrequency 1.3.6.1.4.1.318.1.1.22.4.1.4
The system output frequency in tenths of Hertz. -1 if not available.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageMonitoring 1.3.6.1.4.1.318.1.1.22.4.1.5
Indicates whether or not output voltage alarm generation is present.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

isxModularDistSysOutputVoltageThresholdMin 1.3.6.1.4.1.318.1.1.22.4.1.6
When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageThresholdLow 1.3.6.1.4.1.318.1.1.22.4.1.7
When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageThresholdHigh 1.3.6.1.4.1.318.1.1.22.4.1.8
When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageThresholdMax 1.3.6.1.4.1.318.1.1.22.4.1.9
When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysOutputVoltageAlarmMinEnable 1.3.6.1.4.1.318.1.1.22.4.1.10
Enable or disable minimum voltage alarm generation for the distribution panel.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysOutputVoltageAlarmLowEnable 1.3.6.1.4.1.318.1.1.22.4.1.11
Enable or disable low voltage alarm generation for the distribution panel.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysOutputVoltageAlarmHighEnable 1.3.6.1.4.1.318.1.1.22.4.1.12
Enable or disable high voltage alarm generation for the distribution panel.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysOutputVoltageAlarmMaxEnable 1.3.6.1.4.1.318.1.1.22.4.1.13
Enable or disable maximum voltage alarm generation for the distribution panel.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysOutputVoltageFrequencyTolerance 1.3.6.1.4.1.318.1.1.22.4.1.14
The circuit panel output frequency tolerance in Hertz. When the system output frequency deviates from the nominal by more than this range, a critical alarm will be generated.
OBJECT-TYPE    
  INTEGER freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10), freqToleranceNotAvailable(11)  

isxModularDistSysVoltageTable 1.3.6.1.4.1.318.1.1.22.4.1.15
Allows for getting the system output voltage information.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistSysVoltageEntry

isxModularDistSysVoltageEntry 1.3.6.1.4.1.318.1.1.22.4.1.15.1
An entry containing data for an individual system output phase.
OBJECT-TYPE    
  IsxModularDistSysVoltageEntry  

isxModularDistSysVoltagePhaseIndex 1.3.6.1.4.1.318.1.1.22.4.1.15.1.1
Description of each phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

isxModularDistSysVoltageAlarmStatus 1.3.6.1.4.1.318.1.1.22.4.1.15.1.2
This is a bit map representing the active alarms for this output phase: b0 - Minimum voltage threshold exceeded (critical) b1 - Low voltage threshold exceeded (warning) b2 - High voltage threshold exceeded (warning) b3 - Maximum voltage threshold exceeded (critical) If a bit is set, the corresponding alarm is active.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysVoltageLtoN 1.3.6.1.4.1.318.1.1.22.4.1.15.1.3
Line-to-neutral system output voltage available at the distribution panel. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysVoltageLtoL 1.3.6.1.4.1.318.1.1.22.4.1.15.1.4
Line-to-line system output voltage available at the distribution panel. Measured in tenths of Volts.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrent 1.3.6.1.4.1.318.1.1.22.4.2
OBJECT IDENTIFIER    

isxModularDistSysCurrentRating 1.3.6.1.4.1.318.1.1.22.4.2.1
The 100 percent current rating of the distribution panel.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentMonitoring 1.3.6.1.4.1.318.1.1.22.4.2.2
Indicates whether or not total output current measurements and alarm generation are present.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

isxModularDistSysCurrentThresholdMin 1.3.6.1.4.1.318.1.1.22.4.2.3
When total system current in any phase drops below this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentThresholdLow 1.3.6.1.4.1.318.1.1.22.4.2.4
When total system current in any phase drops below this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentThresholdHigh 1.3.6.1.4.1.318.1.1.22.4.2.5
When total system current in any phase exceeds this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentThresholdMax 1.3.6.1.4.1.318.1.1.22.4.2.6
When total system current in any phase exceeds this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentAlarmMinEnable 1.3.6.1.4.1.318.1.1.22.4.2.7
Enable or disable minimum total output current alarm generation.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysCurrentAlarmLowEnable 1.3.6.1.4.1.318.1.1.22.4.2.8
Enable or disable low total output current alarm generation.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysCurrentAlarmHighEnable 1.3.6.1.4.1.318.1.1.22.4.2.9
Enable or disable high total output current alarm generation.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysCurrentAlarmMaxEnable 1.3.6.1.4.1.318.1.1.22.4.2.10
Enable or disable maximum total output current alarm generation.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

isxModularDistSysCurrentTable 1.3.6.1.4.1.318.1.1.22.4.2.11
Allows for getting the total system phase current information.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistSysCurrentEntry

isxModularDistSysCurrentEntry 1.3.6.1.4.1.318.1.1.22.4.2.11.1
An entry containing data for an individual system output phase.
OBJECT-TYPE    
  IsxModularDistSysCurrentEntry  

isxModularDistSysCurrentPhaseIndex 1.3.6.1.4.1.318.1.1.22.4.2.11.1.1
Description of each phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

isxModularDistSysCurrentAlarmStatus 1.3.6.1.4.1.318.1.1.22.4.2.11.1.2
This is a bit map representing the active alarms for this output phase: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) If a bit is set, the corresponding alarm is active.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentAmps 1.3.6.1.4.1.318.1.1.22.4.2.11.1.3
The current flowing though this system output phase. Measured in tenths of amps.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysCurrentPercent 1.3.6.1.4.1.318.1.1.22.4.2.11.1.4
The loading on this system output phase as a percentage of the panel current rating. Expressed in tenths of percent.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysPower 1.3.6.1.4.1.318.1.1.22.4.3
OBJECT IDENTIFIER    

isxModularDistSysPowerTotal 1.3.6.1.4.1.318.1.1.22.4.3.1
The total system power being supplied. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysPowerKwhUsage 1.3.6.1.4.1.318.1.1.22.4.3.2
The total system energy consumed by the load equipment. This is the total since the date specified in the isxModularDistSysOutputKwhResetDate OID, and may be cleared using the isxModularDistSysOutputKwhReset OID. Measured in tenths of kWh.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysPowerKwhReset 1.3.6.1.4.1.318.1.1.22.4.3.3
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSysPowerKwhUsage OID.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

isxModularDistSysPowerKwhResetDate 1.3.6.1.4.1.318.1.1.22.4.3.4
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
OBJECT-TYPE    
  DisplayString  

isxModularDistSysPowerTable 1.3.6.1.4.1.318.1.1.22.4.3.5
Allows for getting the total system phase power loading information.
OBJECT-TYPE    
  SEQUENCE OF  
    IsxModularDistSysPowerEntry

isxModularDistSysPowerEntry 1.3.6.1.4.1.318.1.1.22.4.3.5.1
An entry containing data for an individual system output phase.
OBJECT-TYPE    
  IsxModularDistSysPowerEntry  

isxModularDistSysPowerPhaseIndex 1.3.6.1.4.1.318.1.1.22.4.3.5.1.1
Description of each phase entry in the table.
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

isxModularDistSysPowerKw 1.3.6.1.4.1.318.1.1.22.4.3.5.1.2
The power being supplied by this system output phase. Measured in tenths of kW.
OBJECT-TYPE    
  INTEGER  

isxModularDistSysPowerKwhPhaseUsage 1.3.6.1.4.1.318.1.1.22.4.3.5.1.3
The energy consumed by the load equipment on this system output phase. This is the total since the date specified in the isxModularDistSysPowerKwhResetDate OID, and may be cleared using the isxModularDistSysPowerKwhReset OID. Measured in tenths of kWh.
OBJECT-TYPE    
  INTEGER  

isxModularPdu 1.3.6.1.4.1.318.1.1.23
OBJECT IDENTIFIER    

isxModularPduIdent 1.3.6.1.4.1.318.1.1.23.1
OBJECT IDENTIFIER    

isxModularPduIdentModelNumber 1.3.6.1.4.1.318.1.1.23.1.1
A character string identifying the model number of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentSerialNumber 1.3.6.1.4.1.318.1.1.23.1.2
A character string identifying the serial number of the PDU. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentDateOfManufacture 1.3.6.1.4.1.318.1.1.23.1.3
The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentMonitorCardSerialNumber 1.3.6.1.4.1.318.1.1.23.1.4
A character string identifying the serial number of the PDU monitor card. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentMonitorCardHardwareRev 1.3.6.1.4.1.318.1.1.23.1.5
The hardware revision of the PDU monitor card. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentMonitorCardFirmwareAppRev 1.3.6.1.4.1.318.1.1.23.1.6
An ID string identifying the application firmware revision of the PDU monitor card.
OBJECT-TYPE    
  DisplayString  

isxModularPduIdentMonitorCardFirmwareAppOSRev 1.3.6.1.4.1.318.1.1.23.1.7
An ID string identifying the application operating system firmware revision of the PDU monitor card.
OBJECT-TYPE    
  DisplayString  

isxModularPduDevice 1.3.6.1.4.1.318.1.1.23.2
OBJECT IDENTIFIER    

isxModularPduDeviceTransformerPresent 1.3.6.1.4.1.318.1.1.23.2.1
Indicates the type of transformer present in this PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), isoXfmrPresent(2), autoXfmrPresent(3)  

isxModularPduDeviceServiceType 1.3.6.1.4.1.318.1.1.23.2.2
The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye).
OBJECT-TYPE    
  INTEGER threeWire(1), fourWire(2)  

isxModularPduDeviceFansPresent 1.3.6.1.4.1.318.1.1.23.2.3
Indicates whether or not cooling fans are installed in the PDU.
OBJECT-TYPE    
  INTEGER notPresent(1), present(2)  

isxModularPduDeviceNominalMainInputVoltage 1.3.6.1.4.1.318.1.1.23.2.4
The nominal main input voltage to the system. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. -1 if main input voltage is not being measured.
OBJECT-TYPE    
  INTEGER  

isxModularPduStatus 1.3.6.1.4.1.318.1.1.23.3
OBJECT IDENTIFIER    

isxModularPduAlarmStatus 1.3.6.1.4.1.318.1.1.23.3.1
The overall status (worst case) of this PDU.
OBJECT-TYPE    
  INTEGER normal(1), warning(2), critical(3)  

isxModularPduTransformerTempStatus 1.3.6.1.4.1.318.1.1.23.3.2
Indicates if the PDU isolation transformer is over temperature.
OBJECT-TYPE    
  INTEGER normal(1), overtemp(2), noTransformerPresent(3), unknown(4)  

isxModularPduFanStatus 1.3.6.1.4.1.318.1.1.23.3.3
Indicates if one or more of the PDU's cooling fans have failed.
OBJECT-TYPE    
  INTEGER normal(1), failed(2), noCoolingFansPresent(3), unknown(4)  

universalInputOutput 1.3.6.1.4.1.318.1.1.25
OBJECT IDENTIFIER    

uioSensor 1.3.6.1.4.1.318.1.1.25.1
OBJECT IDENTIFIER    

uioSensorStatusTableSize 1.3.6.1.4.1.318.1.1.25.1.1
The number of entries in the uioSensorStatusTable.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusTable 1.3.6.1.4.1.318.1.1.25.1.2
Allows for getting sensor status information.
OBJECT-TYPE    
  SEQUENCE OF  
    UIOSensorStatusEntry

uioSensorStatusEntry 1.3.6.1.4.1.318.1.1.25.1.2.1
The unit from which to get data.
OBJECT-TYPE    
  UIOSensorStatusEntry  

uioSensorStatusPortID 1.3.6.1.4.1.318.1.1.25.1.2.1.1
The ID of the Universal IO port to which the sensor is attached.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusSensorID 1.3.6.1.4.1.318.1.1.25.1.2.1.2
The ID of the sensor.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusSensorName 1.3.6.1.4.1.318.1.1.25.1.2.1.3
The sensor name.
OBJECT-TYPE    
  DisplayString  

uioSensorStatusSensorLocation 1.3.6.1.4.1.318.1.1.25.1.2.1.4
The location of the sensor.
OBJECT-TYPE    
  DisplayString  

uioSensorStatusTemperatureDegF 1.3.6.1.4.1.318.1.1.25.1.2.1.5
The sensor's current temperature reading in tenths of degrees Fahrenheit.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusTemperatureDegC 1.3.6.1.4.1.318.1.1.25.1.2.1.6
The sensor's current temperature reading in tenths of degrees Celsius.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusHumidity 1.3.6.1.4.1.318.1.1.25.1.2.1.7
The current humidity reading in tenths of percent from the sensor.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusViolationStatus 1.3.6.1.4.1.318.1.1.25.1.2.1.8
The violation status of the sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded (Not used). 6 0x0020 Short-term decreasing temperature rate exceeded (Not used). 7 0x0040 Long-term increasing temperature rate exceeded (Not used). 8 0x0080 Long-term decreasing temperature rate exceeded (Not used). 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded.
OBJECT-TYPE    
  INTEGER  

uioSensorStatusAlarmStatus 1.3.6.1.4.1.318.1.1.25.1.2.1.9
The alarm status of the sensor.
OBJECT-TYPE    
  INTEGER uioNormal(1), uioWarning(2), uioCritical(3), sensorStatusNotApplicable(4)  

uioSensorStatusCommStatus 1.3.6.1.4.1.318.1.1.25.1.2.1.10
The communications status of the sensor.
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

uioInputContact 1.3.6.1.4.1.318.1.1.25.2
OBJECT IDENTIFIER    

uioInputContactStatusTableSize 1.3.6.1.4.1.318.1.1.25.2.1
The number of entries in the uioInputContactStatusTable.
OBJECT-TYPE    
  INTEGER  

uioInputContactStatusTable 1.3.6.1.4.1.318.1.1.25.2.2
Allows for getting input contact status information.
OBJECT-TYPE    
  SEQUENCE OF  
    UIOInputContactStatusEntry

uioInputContactStatusEntry 1.3.6.1.4.1.318.1.1.25.2.2.1
The input contact from which to get data.
OBJECT-TYPE    
  UIOInputContactStatusEntry  

uioInputContactStatusPortID 1.3.6.1.4.1.318.1.1.25.2.2.1.1
The ID of the port to which the input contact is attached.
OBJECT-TYPE    
  INTEGER  

uioInputContactStatusContactID 1.3.6.1.4.1.318.1.1.25.2.2.1.2
The ID of the input contact on the module.
OBJECT-TYPE    
  INTEGER  

uioInputContactStatusContactName 1.3.6.1.4.1.318.1.1.25.2.2.1.3
The input contact name.
OBJECT-TYPE    
  DisplayString  

uioInputContactStatusContactLocation 1.3.6.1.4.1.318.1.1.25.2.2.1.4
The location of the input contact.
OBJECT-TYPE    
  DisplayString  

uioInputContactStatusCurrentState 1.3.6.1.4.1.318.1.1.25.2.2.1.5
The current state of the input contact.
OBJECT-TYPE    
  INTEGER uioInputClosed(1), uioInputOpen(2), uioInputDisabled(3), inputStateNotApplicable(4)  

uioInputContactStatusAlarmStatus 1.3.6.1.4.1.318.1.1.25.2.2.1.6
The alarm status of the input contact.
OBJECT-TYPE    
  INTEGER uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)  

uioInputContactStatusCommStatus 1.3.6.1.4.1.318.1.1.25.2.2.1.7
The communications status of the input contact.
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

uioOutputRelay 1.3.6.1.4.1.318.1.1.25.3
OBJECT IDENTIFIER    

uioOutputRelayStatusTableSize 1.3.6.1.4.1.318.1.1.25.3.1
The number of entries in the uioOutputRelayStatusTable.
OBJECT-TYPE    
  INTEGER  

uioOutputRelayStatusTable 1.3.6.1.4.1.318.1.1.25.3.2
Allows for getting output relay status information.
OBJECT-TYPE    
  SEQUENCE OF  
    UIOOutputRelayStatusEntry

uioOutputRelayStatusEntry 1.3.6.1.4.1.318.1.1.25.3.2.1
The unit from which to get data.
OBJECT-TYPE    
  UIOOutputRelayStatusEntry  

uioOutputRelayStatusPortID 1.3.6.1.4.1.318.1.1.25.3.2.1.1
The ID of the module to which the output relay is attached.
OBJECT-TYPE    
  INTEGER  

uioOutputRelayStatusRelayID 1.3.6.1.4.1.318.1.1.25.3.2.1.2
The ID of the output relay on the module.
OBJECT-TYPE    
  INTEGER  

uioOutputRelayStatusRelayName 1.3.6.1.4.1.318.1.1.25.3.2.1.3
The output relay name.
OBJECT-TYPE    
  DisplayString  

uioOutputRelayStatusRelayLocation 1.3.6.1.4.1.318.1.1.25.3.2.1.4
The location of the output relay.
OBJECT-TYPE    
  DisplayString  

uioOutputRelayStatusCurrentState 1.3.6.1.4.1.318.1.1.25.3.2.1.5
The current state of the output relay.
OBJECT-TYPE    
  INTEGER uioOutputClosed(1), uioOutputOpen(2), outputStateNotApplicable(3)  

uioOutputRelayStatusAlarmStatus 1.3.6.1.4.1.318.1.1.25.3.2.1.6
The alarm status of the output relay.
OBJECT-TYPE    
  INTEGER uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)  

uioOutputRelayStatusCommStatus 1.3.6.1.4.1.318.1.1.25.3.2.1.7
The communications status of the output relay.
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

rPDU2 1.3.6.1.4.1.318.1.1.26
OBJECT IDENTIFIER    

rPDU2IdentTableSize 1.3.6.1.4.1.318.1.1.26.1
The total number of Rack PDUs
OBJECT-TYPE    
  INTEGER  

rPDU2IdentTable 1.3.6.1.4.1.318.1.1.26.2
A table of Rack PDU identification data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2IdentEntry

rPDU2IdentEntry 1.3.6.1.4.1.318.1.1.26.2.1
Identification data from Rack PDU being queried
OBJECT-TYPE    
  RPDU2IdentEntry  

rPDU2IdentIndex 1.3.6.1.4.1.318.1.1.26.2.1.1
The index to the Rack PDU identification table entry
OBJECT-TYPE    
  INTEGER  

rPDU2IdentModule 1.3.6.1.4.1.318.1.1.26.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2IdentName 1.3.6.1.4.1.318.1.1.26.2.1.3
A user-defined string identifying the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2IdentLocation 1.3.6.1.4.1.318.1.1.26.2.1.4
A user-defined string identifying the location of the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2IdentHardwareRev 1.3.6.1.4.1.318.1.1.26.2.1.5
The Rack PDU hardware version
OBJECT-TYPE    
  DisplayString  

rPDU2IdentFirmwareRev 1.3.6.1.4.1.318.1.1.26.2.1.6
The Rack PDU firware version
OBJECT-TYPE    
  DisplayString  

rPDU2IdentDateOfManufacture 1.3.6.1.4.1.318.1.1.26.2.1.7
The date the Rack PDU was manufactured in mm/dd/yyyy format
OBJECT-TYPE    
  DisplayString  

rPDU2IdentModelNumber 1.3.6.1.4.1.318.1.1.26.2.1.8
The Rack PDU model number
OBJECT-TYPE    
  DisplayString  

rPDU2IdentSerialNumber 1.3.6.1.4.1.318.1.1.26.2.1.9
The Rack PDU serial number
OBJECT-TYPE    
  DisplayString  

rPDU2IdentContact 1.3.6.1.4.1.318.1.1.26.2.1.10
A user-defined string identifying the person to contact regarding the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceTableSize 1.3.6.1.4.1.318.1.1.26.3
The total number of Rack PDUs
OBJECT-TYPE    
  INTEGER  

rPDU2Device 1.3.6.1.4.1.318.1.1.26.4
OBJECT IDENTIFIER    

rPDU2DeviceConfigTable 1.3.6.1.4.1.318.1.1.26.4.1
A table of Rack PDU configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2DeviceConfigEntry

rPDU2DeviceConfigEntry 1.3.6.1.4.1.318.1.1.26.4.1.1
Configuration data from Rack PDU being queried
OBJECT-TYPE    
  RPDU2DeviceConfigEntry  

rPDU2DeviceConfigIndex 1.3.6.1.4.1.318.1.1.26.4.1.1.1
The index to the Rack PDU table entry
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigModule 1.3.6.1.4.1.318.1.1.26.4.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigName 1.3.6.1.4.1.318.1.1.26.4.1.1.3
A user-defined string identifying the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceConfigLocation 1.3.6.1.4.1.318.1.1.26.4.1.1.4
A user-defined string identifying the location of the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceConfigDisplayOrientation 1.3.6.1.4.1.318.1.1.26.4.1.1.5
Indicates the intended physical orientation of the seven segment display displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation
OBJECT-TYPE    
  INTEGER displayNormal(1), displayReverse(2)  

rPDU2DeviceConfigColdstartDelay 1.3.6.1.4.1.318.1.1.26.4.1.1.6
The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigLowLoadPowerThreshold 1.3.6.1.4.1.318.1.1.26.4.1.1.7
User-defined low power draw alarm threshold, measured in tenths of kilowatts
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigNearOverloadPowerThreshold 1.3.6.1.4.1.318.1.1.26.4.1.1.8
User-defined near power overload threshold, measured in tenths of kilowatts
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigOverloadPowerThreshold 1.3.6.1.4.1.318.1.1.26.4.1.1.9
User-defined power overload threshold, measured in tenths of kilowatts
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceConfigDevicePeakPowerReset 1.3.6.1.4.1.318.1.1.26.4.1.1.10
Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2)  

rPDU2DeviceConfigDeviceEnergyReset 1.3.6.1.4.1.318.1.1.26.4.1.1.11
Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2), notSupported(3)  

rPDU2DeviceConfigOutletsEnergyReset 1.3.6.1.4.1.318.1.1.26.4.1.1.12
Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2), notSupported(3)  

rPDU2DevicePropertiesTable 1.3.6.1.4.1.318.1.1.26.4.2
A table of Rack PDU properties
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2DevicePropertiesEntry

rPDU2DevicePropertiesEntry 1.3.6.1.4.1.318.1.1.26.4.2.1
Properties of the Rack PDU being queried
OBJECT-TYPE    
  RPDU2DevicePropertiesEntry  

rPDU2DevicePropertiesIndex 1.3.6.1.4.1.318.1.1.26.4.2.1.1
The index to the Rack PDU properties table entry
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesModule 1.3.6.1.4.1.318.1.1.26.4.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesName 1.3.6.1.4.1.318.1.1.26.4.2.1.3
A user-defined string identifying the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DevicePropertiesNumOutlets 1.3.6.1.4.1.318.1.1.26.4.2.1.4
The number of outlets on the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesNumSwitchedOutlets 1.3.6.1.4.1.318.1.1.26.4.2.1.5
The number of switched outlets on the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesNumMeteredOutlets 1.3.6.1.4.1.318.1.1.26.4.2.1.6
The number of metered outlets on the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesNumPhases 1.3.6.1.4.1.318.1.1.26.4.2.1.7
The number of phases present in the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesNumMeteredBanks 1.3.6.1.4.1.318.1.1.26.4.2.1.8
The number of metered banks present in the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesMaxCurrentRating 1.3.6.1.4.1.318.1.1.26.4.2.1.9
The maximum current rating, measured in Amps, for the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DevicePropertiesOrientation 1.3.6.1.4.1.318.1.1.26.4.2.1.10
Rack PDU orientation
OBJECT-TYPE    
  INTEGER horizontal(1), vertical(2), verticalISXv2(3)  

rPDU2DevicePropertiesOutletLayout 1.3.6.1.4.1.318.1.1.26.4.2.1.11
Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces for AP88XX SKUs. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available.
OBJECT-TYPE    
  INTEGER seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9)  

rPDU2DevicePropertiesMaxPhaseCurrentRating 1.3.6.1.4.1.318.1.1.26.4.2.1.12
The maximum current rating, measured in Amps, for the Rack PDU
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusTable 1.3.6.1.4.1.318.1.1.26.4.3
A table of Rack PDU status information
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2DeviceStatusEntry

rPDU2DeviceStatusEntry 1.3.6.1.4.1.318.1.1.26.4.3.1
Status information from the Rack PDU being queried
OBJECT-TYPE    
  RPDU2DeviceStatusEntry  

rPDU2DeviceStatusIndex 1.3.6.1.4.1.318.1.1.26.4.3.1.1
The index to the Rack PDU status table entry
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusModule 1.3.6.1.4.1.318.1.1.26.4.3.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusName 1.3.6.1.4.1.318.1.1.26.4.3.1.3
A user-defined string identifying the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceStatusLoadState 1.3.6.1.4.1.318.1.1.26.4.3.1.4
Indicates the present load status of the Rack PDU
OBJECT-TYPE    
  INTEGER lowLoad(1), normal(2), nearOverload(3), overload(4)  

rPDU2DeviceStatusPower 1.3.6.1.4.1.318.1.1.26.4.3.1.5
The power consumption of the Rack PDU load in hundredths of kilowatts
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusPeakPower 1.3.6.1.4.1.318.1.1.26.4.3.1.6
The peak power consumption of the Rack PDU load in hundredths of kilowatts
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusPeakPowerTimestamp 1.3.6.1.4.1.318.1.1.26.4.3.1.7
Indicates the date and time that peak power consumption occurred
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceStatusPeakPowerStartTime 1.3.6.1.4.1.318.1.1.26.4.3.1.8
Indicates the date and time of the last device peak power reset
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceStatusEnergy 1.3.6.1.4.1.318.1.1.26.4.3.1.9
A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceStatusEnergyStartTime 1.3.6.1.4.1.318.1.1.26.4.3.1.10
Indicates the date and time of the last device energy meter reset
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceStatusCommandPending 1.3.6.1.4.1.318.1.1.26.4.3.1.11
Indicates whether or not the device is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition.
OBJECT-TYPE    
  INTEGER commandPending(1), noCommandPending(2), commandPendingUnknown(3)  

rPDU2DeviceStatusPowerSupplyAlarm 1.3.6.1.4.1.318.1.1.26.4.3.1.12
Indicates a power supply alarm is active when value equals alarm (2)
OBJECT-TYPE    
  INTEGER normal(1), alarm(2)  

rPDU2DeviceStatusPowerSupply1Status 1.3.6.1.4.1.318.1.1.26.4.3.1.13
Indicates whether or not an alarm is active in Power Supply 1
OBJECT-TYPE    
  INTEGER normal(1), alarm(2), notInstalled(3)  

rPDU2DeviceStatusPowerSupply2Status 1.3.6.1.4.1.318.1.1.26.4.3.1.14
Indicates whether or not an alarm is active in Power Supply 2
OBJECT-TYPE    
  INTEGER normal(1), alarm(2), notInstalled(3)  

rPDU2DeviceStatusOutletsEnergyStartTime 1.3.6.1.4.1.318.1.1.26.4.3.1.15
Indicates the date and time of the last outlets energy meter reset
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceControlTable 1.3.6.1.4.1.318.1.1.26.4.4
A table of Rack PDU control data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2DeviceControlEntry

rPDU2DeviceControlEntry 1.3.6.1.4.1.318.1.1.26.4.4.1
Control data from Rack PDU being queried
OBJECT-TYPE    
  RPDU2DeviceControlEntry  

rPDU2DeviceControlIndex 1.3.6.1.4.1.318.1.1.26.4.4.1.1
The index to the Rack PDU control table entry
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceControlModule 1.3.6.1.4.1.318.1.1.26.4.4.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2DeviceControlName 1.3.6.1.4.1.318.1.1.26.4.4.1.3
A user-defined string identifying the Rack PDU
OBJECT-TYPE    
  DisplayString  

rPDU2DeviceControlCommand 1.3.6.1.4.1.318.1.1.26.4.4.1.4
Setting this OID to immediateAllOn (1) will turn all outlets on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime OID value. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will cause an immediateAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateAllOn command. Setting this OID to delayedAllReboot (5) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to noCommandAll (6) will have no effect. Setting this OID to delayedAllOff (7) will turn all outlets off as defined by each outlet's rPDU2OutletSwitchedConfigPowerOffTime OID value. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be cancelled. Getting this OID will return the noCommandAll (6) value.
OBJECT-TYPE    
  INTEGER immediateAllOn(1), delayedAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllReboot(5), noCommandAll(6), delayedAllOff(7), cancelAllPendingCommands(8)  

rPDU2PhaseTableSize 1.3.6.1.4.1.318.1.1.26.5
The number of connected Rack PDU phases
OBJECT-TYPE    
  INTEGER  

rPDU2Phase 1.3.6.1.4.1.318.1.1.26.6
OBJECT IDENTIFIER    

rPDU2PhaseConfigTable 1.3.6.1.4.1.318.1.1.26.6.1
A table of Rack PDU phase configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2PhaseConfigEntry

rPDU2PhaseConfigEntry 1.3.6.1.4.1.318.1.1.26.6.1.1
Configuration data from currently queried Rack PDU phase
OBJECT-TYPE    
  RPDU2PhaseConfigEntry  

rPDU2PhaseConfigIndex 1.3.6.1.4.1.318.1.1.26.6.1.1.1
The index to the Rack PDU phase configuration table entry
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseConfigModule 1.3.6.1.4.1.318.1.1.26.6.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseConfigNumber 1.3.6.1.4.1.318.1.1.26.6.1.1.3
The numeric phase ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseConfigOverloadRestriction 1.3.6.1.4.1.318.1.1.26.6.1.1.4
This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail.
OBJECT-TYPE    
  INTEGER alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)  

rPDU2PhaseConfigLowLoadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.6.1.1.5
User-defined low load phase current threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseConfigNearOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.6.1.1.6
User-defined near phase overload warning threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseConfigOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.6.1.1.7
User-defined phase overload current threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2PhasePropertiesTable 1.3.6.1.4.1.318.1.1.26.6.2
A table of Rack PDU phase properties
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2PhasePropertiesEntry

rPDU2PhasePropertiesEntry 1.3.6.1.4.1.318.1.1.26.6.2.1
Properties of the currently queried Rack PDU phase
OBJECT-TYPE    
  RPDU2PhasePropertiesEntry  

rPDU2PhasePropertiesIndex 1.3.6.1.4.1.318.1.1.26.6.2.1.1
The index to the Rack PDU phase properties table entry
OBJECT-TYPE    
  INTEGER  

rPDU2PhasePropertiesModule 1.3.6.1.4.1.318.1.1.26.6.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhasePropertiesNumber 1.3.6.1.4.1.318.1.1.26.6.2.1.3
The numeric phase ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusTable 1.3.6.1.4.1.318.1.1.26.6.3
A table of Rack PDU phase status data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2PhaseStatusEntry

rPDU2PhaseStatusEntry 1.3.6.1.4.1.318.1.1.26.6.3.1
Status data from currently queried Rack PDU phase
OBJECT-TYPE    
  RPDU2PhaseStatusEntry  

rPDU2PhaseStatusIndex 1.3.6.1.4.1.318.1.1.26.6.3.1.1
The index to the Rack PDU phase status table entry
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusModule 1.3.6.1.4.1.318.1.1.26.6.3.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusNumber 1.3.6.1.4.1.318.1.1.26.6.3.1.3
The numeric phase ID
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusLoadState 1.3.6.1.4.1.318.1.1.26.6.3.1.4
Indicates the present load status of the Rack PDU phase being queried
OBJECT-TYPE    
  INTEGER lowLoad(1), normal(2), nearOverload(3), overload(4)  

rPDU2PhaseStatusCurrent 1.3.6.1.4.1.318.1.1.26.6.3.1.5
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU phase being queried
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusVoltage 1.3.6.1.4.1.318.1.1.26.6.3.1.6
Indicates the Voltage, in Volts, of the Rack PDU phase being queried
OBJECT-TYPE    
  INTEGER  

rPDU2PhaseStatusPower 1.3.6.1.4.1.318.1.1.26.6.3.1.7
Indicates the load power, in hundredths of kilowatts, consumed on the Rack PDU phase being queried
OBJECT-TYPE    
  INTEGER  

rPDU2BankTableSize 1.3.6.1.4.1.318.1.1.26.7
The number of connected Rack PDU banks
OBJECT-TYPE    
  INTEGER  

rPDU2Bank 1.3.6.1.4.1.318.1.1.26.8
OBJECT IDENTIFIER    

rPDU2BankConfigTable 1.3.6.1.4.1.318.1.1.26.8.1
A table of Rack PDU bank configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2BankConfigEntry

rPDU2BankConfigEntry 1.3.6.1.4.1.318.1.1.26.8.1.1
Configuration data from currently queried Rack PDU bank
OBJECT-TYPE    
  RPDU2BankConfigEntry  

rPDU2BankConfigIndex 1.3.6.1.4.1.318.1.1.26.8.1.1.1
The index to the Rack PDU bank configuration table entry
OBJECT-TYPE    
  INTEGER  

rPDU2BankConfigModule 1.3.6.1.4.1.318.1.1.26.8.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankConfigNumber 1.3.6.1.4.1.318.1.1.26.8.1.1.3
The numeric bank ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankConfigOverloadRestriction 1.3.6.1.4.1.318.1.1.26.8.1.1.4
This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigNearOverloadCurrentThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigOverloadCurrentThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail.
OBJECT-TYPE    
  INTEGER alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)  

rPDU2BankConfigLowLoadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.8.1.1.5
User-defined low load bank current threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2BankConfigNearOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.8.1.1.6
User-defined near bank overload current warning threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2BankConfigOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.8.1.1.7
User-defined bank overload current threshold in Amps
OBJECT-TYPE    
  INTEGER  

rPDU2BankPropertiesTable 1.3.6.1.4.1.318.1.1.26.8.2
A table of Rack PDU bank properties
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2BankPropertiesEntry

rPDU2BankPropertiesEntry 1.3.6.1.4.1.318.1.1.26.8.2.1
Properties of the currently queried Rack PDU bank
OBJECT-TYPE    
  RPDU2BankPropertiesEntry  

rPDU2BankPropertiesIndex 1.3.6.1.4.1.318.1.1.26.8.2.1.1
The index to the Rack PDU bank properties table entry
OBJECT-TYPE    
  INTEGER  

rPDU2BankPropertiesModule 1.3.6.1.4.1.318.1.1.26.8.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankPropertiesNumber 1.3.6.1.4.1.318.1.1.26.8.2.1.3
The numeric bank ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankPropertiesPhaseLayout 1.3.6.1.4.1.318.1.1.26.8.2.1.4
This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that bank outlets are wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that bank outlets are wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that bank outlets are wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that bank outlets are wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that bank outlets are wired from Phase 3 to Phase 1.
OBJECT-TYPE    
  Rpdu2OutletPhaseLayoutType  

rPDU2BankStatusTable 1.3.6.1.4.1.318.1.1.26.8.3
A table of Rack PDU bank status data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2BankStatusEntry

rPDU2BankStatusEntry 1.3.6.1.4.1.318.1.1.26.8.3.1
Status data from currently queried Rack PDU bank
OBJECT-TYPE    
  RPDU2BankStatusEntry  

rPDU2BankStatusIndex 1.3.6.1.4.1.318.1.1.26.8.3.1.1
The index to the Rack PDU bank status table entry
OBJECT-TYPE    
  INTEGER  

rPDU2BankStatusModule 1.3.6.1.4.1.318.1.1.26.8.3.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankStatusNumber 1.3.6.1.4.1.318.1.1.26.8.3.1.3
The numeric bank ID
OBJECT-TYPE    
  INTEGER  

rPDU2BankStatusLoadState 1.3.6.1.4.1.318.1.1.26.8.3.1.4
Indicates the present load status of the Rack PDU bank being queried
OBJECT-TYPE    
  INTEGER lowLoad(1), normal(2), nearOverload(3), overload(4)  

rPDU2BankStatusCurrent 1.3.6.1.4.1.318.1.1.26.8.3.1.5
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU bank being queried
OBJECT-TYPE    
  INTEGER  

rPDU2Outlet 1.3.6.1.4.1.318.1.1.26.9
OBJECT IDENTIFIER    

rPDU2OutletSwitchedTableSize 1.3.6.1.4.1.318.1.1.26.9.1
The number of switched outlets on connected Rack PDUs
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitched 1.3.6.1.4.1.318.1.1.26.9.2
OBJECT IDENTIFIER    

rPDU2OutletSwitchedConfigTable 1.3.6.1.4.1.318.1.1.26.9.2.1
A table of Rack PDU switched outlet configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletSwitchedConfigEntry

rPDU2OutletSwitchedConfigEntry 1.3.6.1.4.1.318.1.1.26.9.2.1.1
Configuration data from currently queried Rack PDU switched outlet
OBJECT-TYPE    
  RPDU2OutletSwitchedConfigEntry  

rPDU2OutletSwitchedConfigIndex 1.3.6.1.4.1.318.1.1.26.9.2.1.1.1
The index to the Rack PDU switched outlet configuration table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedConfigModule 1.3.6.1.4.1.318.1.1.26.9.2.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedConfigName 1.3.6.1.4.1.318.1.1.26.9.2.1.1.3
The user-defined switched outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletSwitchedConfigNumber 1.3.6.1.4.1.318.1.1.26.9.2.1.1.4
The numeric switched outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedConfigPowerOnTime 1.3.6.1.4.1.318.1.1.26.9.2.1.1.5
The amount of delay, in seconds, between when power is provided to the Rack PDU and when this switched outlet starts providing power
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedConfigPowerOffTime 1.3.6.1.4.1.318.1.1.26.9.2.1.1.6
The amount of time, in seconds, this outlet will delay powering off
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedConfigRebootDuration 1.3.6.1.4.1.318.1.1.26.9.2.1.1.7
After turning power off during a reboot sequence, the amount of time to wait before turning power to this outlet back on
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedPropertiesTable 1.3.6.1.4.1.318.1.1.26.9.2.2
A table of Rack PDU switched outlet properties
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletSwitchedPropertiesEntry

rPDU2OutletSwitchedPropertiesEntry 1.3.6.1.4.1.318.1.1.26.9.2.2.1
Properties of the currently queried Rack PDU switched outlet
OBJECT-TYPE    
  RPDU2OutletSwitchedPropertiesEntry  

rPDU2OutletSwitchedPropertiesIndex 1.3.6.1.4.1.318.1.1.26.9.2.2.1.1
The index to the Rack PDU switched outlet properties table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedPropertiesModule 1.3.6.1.4.1.318.1.1.26.9.2.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedPropertiesName 1.3.6.1.4.1.318.1.1.26.9.2.2.1.3
The user-defined switched outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletSwitchedPropertiesNumber 1.3.6.1.4.1.318.1.1.26.9.2.2.1.4
The numeric switched outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedPropertiesPhaseLayout 1.3.6.1.4.1.318.1.1.26.9.2.2.1.5
This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1.
OBJECT-TYPE    
  Rpdu2OutletPhaseLayoutType  

rPDU2OutletSwitchedPropertiesBank 1.3.6.1.4.1.318.1.1.26.9.2.2.1.6
The numeric bank ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedStatusTable 1.3.6.1.4.1.318.1.1.26.9.2.3
A table of Rack PDU switched outlet status information
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletSwitchedStatusEntry

rPDU2OutletSwitchedStatusEntry 1.3.6.1.4.1.318.1.1.26.9.2.3.1
Status information for currently queried Rack PDU switched outlet
OBJECT-TYPE    
  RPDU2OutletSwitchedStatusEntry  

rPDU2OutletSwitchedStatusIndex 1.3.6.1.4.1.318.1.1.26.9.2.3.1.1
The index to the Rack PDU switched outlet status information table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedStatusModule 1.3.6.1.4.1.318.1.1.26.9.2.3.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedStatusName 1.3.6.1.4.1.318.1.1.26.9.2.3.1.3
The user-defined switched outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletSwitchedStatusNumber 1.3.6.1.4.1.318.1.1.26.9.2.3.1.4
The numeric switched outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedStatusState 1.3.6.1.4.1.318.1.1.26.9.2.3.1.5
Indicates the present switch state of the Rack PDU switched outlet being queried
OBJECT-TYPE    
  INTEGER off(1), on(2)  

rPDU2OutletSwitchedStatusCommandPending 1.3.6.1.4.1.318.1.1.26.9.2.3.1.6
Indicates whether or not the device is processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition.
OBJECT-TYPE    
  INTEGER commandPending(1), noCommandPending(2), commandPendingUnknown(3)  

rPDU2OutletSwitchedControlTable 1.3.6.1.4.1.318.1.1.26.9.2.4
A table of Rack PDU switched outlet control data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletSwitchedControlEntry

rPDU2OutletSwitchedControlEntry 1.3.6.1.4.1.318.1.1.26.9.2.4.1
Control data for currently queried Rack PDU switched outlet
OBJECT-TYPE    
  RPDU2OutletSwitchedControlEntry  

rPDU2OutletSwitchedControlIndex 1.3.6.1.4.1.318.1.1.26.9.2.4.1.1
The index to the Rack PDU switched outlet control data table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedControlModule 1.3.6.1.4.1.318.1.1.26.9.2.4.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedControlName 1.3.6.1.4.1.318.1.1.26.9.2.4.1.3
The user-defined switched outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletSwitchedControlNumber 1.3.6.1.4.1.318.1.1.26.9.2.4.1.4
The numeric switched outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletSwitchedControlCommand 1.3.6.1.4.1.318.1.1.26.9.2.4.1.5
Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will cause the Switched Rack PDU to perform an immediateOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateOn command. Setting this variable to delayedOn (5) will turn the outlet on after the rPDU2OutletSwitchedConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (6) will turn the outlet off after the rPDU2OutletSwitchedConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (7) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (8) will cause any pending command to this outlet to be cancelled.
OBJECT-TYPE    
  INTEGER immediateOn(1), immediateOff(2), immediateReboot(3), outletUnknown(4), delayedOn(5), delayedOff(6), delayedReboot(7), cancelPendingCommand(8)  

rPDU2OutletMeteredTableSize 1.3.6.1.4.1.318.1.1.26.9.3
The number of metered outlets on connect Rack PDUs
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMetered 1.3.6.1.4.1.318.1.1.26.9.4
OBJECT IDENTIFIER    

rPDU2OutletMeteredConfigTable 1.3.6.1.4.1.318.1.1.26.9.4.1
A table of Rack PDU metered outlet configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletMeteredConfigEntry

rPDU2OutletMeteredConfigEntry 1.3.6.1.4.1.318.1.1.26.9.4.1.1
Configuration data from currently queried Rack PDU metered outlet
OBJECT-TYPE    
  RPDU2OutletMeteredConfigEntry  

rPDU2OutletMeteredConfigIndex 1.3.6.1.4.1.318.1.1.26.9.4.1.1.1
The index to the Rack PDU metered outlet configuration table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredConfigModule 1.3.6.1.4.1.318.1.1.26.9.4.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredConfigName 1.3.6.1.4.1.318.1.1.26.9.4.1.1.3
The user-defined metered outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletMeteredConfigNumber 1.3.6.1.4.1.318.1.1.26.9.4.1.1.4
The numeric switched outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredConfigLowLoadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.9.4.1.1.5
User-defined low load outlet current threshold in Watts
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredConfigNearOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.9.4.1.1.6
User-defined near outlet overload warning threshold in Watts
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredConfigOverloadCurrentThreshold 1.3.6.1.4.1.318.1.1.26.9.4.1.1.7
User-defined outlet overload current threshold in Watts
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredPropertiesTable 1.3.6.1.4.1.318.1.1.26.9.4.2
A table of Rack PDU metered outlet properties
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletMeteredPropertiesEntry

rPDU2OutletMeteredPropertiesEntry 1.3.6.1.4.1.318.1.1.26.9.4.2.1
Properties of currently queried Rack PDU metered outlet
OBJECT-TYPE    
  RPDU2OutletMeteredPropertiesEntry  

rPDU2OutletMeteredPropertiesIndex 1.3.6.1.4.1.318.1.1.26.9.4.2.1.1
The index to the Rack PDU metered properties table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredPropertiesModule 1.3.6.1.4.1.318.1.1.26.9.4.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredPropertiesName 1.3.6.1.4.1.318.1.1.26.9.4.2.1.3
The user-defined metered outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletMeteredPropertiesNumber 1.3.6.1.4.1.318.1.1.26.9.4.2.1.4
The numeric metered outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredPropertiesLayout 1.3.6.1.4.1.318.1.1.26.9.4.2.1.5
This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1.
OBJECT-TYPE    
  Rpdu2OutletPhaseLayoutType  

rPDU2OutletMeteredPropertiesPowerRating 1.3.6.1.4.1.318.1.1.26.9.4.2.1.6
Maximum power rating of Rack PDU metered outlet
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredPropertiesBank 1.3.6.1.4.1.318.1.1.26.9.4.2.1.7
This outlet's numeric bank ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusTable 1.3.6.1.4.1.318.1.1.26.9.4.3
A table of Rack PDU metered outlet status data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2OutletMeteredStatusEntry

rPDU2OutletMeteredStatusEntry 1.3.6.1.4.1.318.1.1.26.9.4.3.1
Status data from currently queried Rack PDU metered outlet
OBJECT-TYPE    
  RPDU2OutletMeteredStatusEntry  

rPDU2OutletMeteredStatusIndex 1.3.6.1.4.1.318.1.1.26.9.4.3.1.1
The index to the Rack PDU metered status table entry
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusModule 1.3.6.1.4.1.318.1.1.26.9.4.3.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusName 1.3.6.1.4.1.318.1.1.26.9.4.3.1.3
The user-defined metered outlet ID string
OBJECT-TYPE    
  DisplayString  

rPDU2OutletMeteredStatusNumber 1.3.6.1.4.1.318.1.1.26.9.4.3.1.4
The numeric metered outlet ID
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusState 1.3.6.1.4.1.318.1.1.26.9.4.3.1.5
Indicates the present load status of the Rack PDU metered outlet being queried
OBJECT-TYPE    
  INTEGER lowLoad(1), normal(2), nearOverload(3), overload(4)  

rPDU2OutletMeteredStatusCurrent 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU outlet being queried
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusPower 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7
Indicates the power draw of the load on the Rack PDU outlet being queried
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusPeakPower 1.3.6.1.4.1.318.1.1.26.9.4.3.1.8
Indicates the peak power load draw on the Rack PDU outlet being queried
OBJECT-TYPE    
  INTEGER  

rPDU2OutletMeteredStatusPeakPowerTimestamp 1.3.6.1.4.1.318.1.1.26.9.4.3.1.9
Indicates the date and time that this metered outlet's peak power consumption occurred
OBJECT-TYPE    
  DisplayString  

rPDU2OutletMeteredStatusPeakPowerStartTime 1.3.6.1.4.1.318.1.1.26.9.4.3.1.10
Indicates the start date and time that this metered outlet began recording peak power observations
OBJECT-TYPE    
  DisplayString  

rPDU2OutletMeteredStatusEnergy 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11
A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours
OBJECT-TYPE    
  INTEGER  

rPDU2Sensor 1.3.6.1.4.1.318.1.1.26.10
OBJECT IDENTIFIER    

rPDU2SensorTempHumidityTableSize 1.3.6.1.4.1.318.1.1.26.10.1
The number of connected temperature-humidity sensors
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidity 1.3.6.1.4.1.318.1.1.26.10.2
OBJECT IDENTIFIER    

rPDU2SensorTempHumidityConfigTable 1.3.6.1.4.1.318.1.1.26.10.2.1
A table of temperature-humidity sensor configuration data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2SensorTempHumidityConfigEntry

rPDU2SensorTempHumidityConfigEntry 1.3.6.1.4.1.318.1.1.26.10.2.1.1
Configuration data from temperature-humidity sensor being queried
OBJECT-TYPE    
  RPDU2SensorTempHumidityConfigEntry  

rPDU2SensorTempHumidityConfigIndex 1.3.6.1.4.1.318.1.1.26.10.2.1.1.1
The index to the temperature-humidity sensor configuration data table entry
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigModule 1.3.6.1.4.1.318.1.1.26.10.2.1.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigName 1.3.6.1.4.1.318.1.1.26.10.2.1.1.3
The user-defined temperature-humidity sensor ID string
OBJECT-TYPE    
  DisplayString  

rPDU2SensorTempHumidityConfigNumber 1.3.6.1.4.1.318.1.1.26.10.2.1.1.4
The temperature-humidity sensor numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTemperatureAlarmEnable 1.3.6.1.4.1.318.1.1.26.10.2.1.1.5
Setting this OID enables or disables generation of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

rPDU2SensorTempHumidityConfigHumidityAlarmEnable 1.3.6.1.4.1.318.1.1.26.10.2.1.1.6
Setting this OID enables or disables generation of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable.
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

rPDU2SensorTempHumidityConfigTempMaxThreshF 1.3.6.1.4.1.318.1.1.26.10.2.1.1.7
Sensor maximum temperature alarm threshold in Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTempHighThreshF 1.3.6.1.4.1.318.1.1.26.10.2.1.1.8
Sensor high temperature warning alarm threshold in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTempHysteresisF 1.3.6.1.4.1.318.1.1.26.10.2.1.1.9
Sensor temperature hysteresis setting in Fahrenheit
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTempMaxThreshC 1.3.6.1.4.1.318.1.1.26.10.2.1.1.10
Sensor maximum temperature alarm threshold in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTempHighThreshC 1.3.6.1.4.1.318.1.1.26.10.2.1.1.11
Sensor high temperature warning alarm threshold in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigTempHysteresisC 1.3.6.1.4.1.318.1.1.26.10.2.1.1.12
Sensor temperature hysteresis setting in Celsius
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigHumidityLowThresh 1.3.6.1.4.1.318.1.1.26.10.2.1.1.13
Sensor low humidity warning alarm threshold in percent relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigHumidityMinThresh will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigHumidityMinThresh 1.3.6.1.4.1.318.1.1.26.10.2.1.1.14
Sensor minimum humidity alarm threshold in percent relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigHumidityLowThresh will result in an error.
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityConfigHumidityHysteresis 1.3.6.1.4.1.318.1.1.26.10.2.1.1.15
Sensor humidity hysteresis setting in percent relative humidity
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusTable 1.3.6.1.4.1.318.1.1.26.10.2.2
A table of temperature-humidity sensor status data
OBJECT-TYPE    
  SEQUENCE OF  
    RPDU2SensorTempHumidityStatusEntry

rPDU2SensorTempHumidityStatusEntry 1.3.6.1.4.1.318.1.1.26.10.2.2.1
Status information from temperature-humidity sensor being queried
OBJECT-TYPE    
  RPDU2SensorTempHumidityStatusEntry  

rPDU2SensorTempHumidityStatusIndex 1.3.6.1.4.1.318.1.1.26.10.2.2.1.1
The index to the temperature-humidity status data table entry
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusModule 1.3.6.1.4.1.318.1.1.26.10.2.2.1.2
The user-defined Rack PDU numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusName 1.3.6.1.4.1.318.1.1.26.10.2.2.1.3
The user-defined temperature-humidity sensor ID string
OBJECT-TYPE    
  DisplayString  

rPDU2SensorTempHumidityStatusNumber 1.3.6.1.4.1.318.1.1.26.10.2.2.1.4
The temperature-humidity sensor numeric ID
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusType 1.3.6.1.4.1.318.1.1.26.10.2.2.1.5
The type of the sensor
OBJECT-TYPE    
  INTEGER temperatureOnly(1), temperatureHumidity(2), commsLost(3), notInstalled(4)  

rPDU2SensorTempHumidityStatusCommStatus 1.3.6.1.4.1.318.1.1.26.10.2.2.1.6
The communications status of the sensor
OBJECT-TYPE    
  INTEGER notInstalled(1), commsOK(2), commsLost(3)  

rPDU2SensorTempHumidityStatusTempF 1.3.6.1.4.1.318.1.1.26.10.2.2.1.7
Sensor temperature reading in tenths of degrees Fahrenheit
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusTempC 1.3.6.1.4.1.318.1.1.26.10.2.2.1.8
Sensor temperature reading in tenths of degrees Celsius
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusTempStatus 1.3.6.1.4.1.318.1.1.26.10.2.2.1.9
This OID reports the current state of the temperature probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured temperature lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured temperature lies below the low threshold. A normal (4) response indicates that the probe is present and its measured temperature lies within all temperature thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a temperature above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a temperature above the max threshold.
OBJECT-TYPE    
  INTEGER notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)  

rPDU2SensorTempHumidityStatusRelativeHumidity 1.3.6.1.4.1.318.1.1.26.10.2.2.1.10
Sensor humidity reading in percent relative humidity
OBJECT-TYPE    
  INTEGER  

rPDU2SensorTempHumidityStatusHumidityStatus 1.3.6.1.4.1.318.1.1.26.10.2.2.1.11
This OID reports the current state of the humidity probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidity lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured humidity lies below the low threshold. A normal (4) response indicates that the probe is present and its measured humidity lies within all humidity thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a humidity above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a humidity above the max threshold.
OBJECT-TYPE    
  INTEGER notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)  

rPDU2Group 1.3.6.1.4.1.318.1.1.26.11
OBJECT IDENTIFIER    

rPDU2GroupNumberOfDevices 1.3.6.1.4.1.318.1.1.26.11.1
Getting this OID will return the number of Rack PDU devices contributing to the group power and energy values.
OBJECT-TYPE    
  INTEGER  

rPDU2GroupTotalPower 1.3.6.1.4.1.318.1.1.26.11.2
Getting this OID will return the total power consumption of the Rack PDU group devices in hundredths of kilowatts.
OBJECT-TYPE    
  INTEGER  

rPDU2GroupTotalEnergy 1.3.6.1.4.1.318.1.1.26.11.3
Getting this OID will return the total energy consumption of the Rack PDU group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the rPDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID.
OBJECT-TYPE    
  INTEGER  

rPDU2GroupEnergyReset 1.3.6.1.4.1.318.1.1.26.11.4
Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU group to be reset to zero. Each device in the Rack PDU group will also have its corresponding rPDU2DeviceStatusEnergyStartTime OID value updated. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2), notSupported(3)  

software 1.3.6.1.4.1.318.1.2
OBJECT IDENTIFIER    

powerNetSubAgent 1.3.6.1.4.1.318.1.2.1
OBJECT IDENTIFIER    

powerNetSoftwareSystem 1.3.6.1.4.1.318.1.2.1.1
OBJECT IDENTIFIER    

powerNetSoftwareSystemDescription 1.3.6.1.4.1.318.1.2.1.1.1
A brief description of the PowerNet sub-agent.
OBJECT-TYPE    
  DisplayString SIZE(0..79)  

powerNetSoftwareOid 1.3.6.1.4.1.318.1.2.1.1.2
The object identifier of the PowerNet sub-agent.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

powerNetSoftwareSystemUpTime 1.3.6.1.4.1.318.1.2.1.1.3
The time that the sub-agent has been running.
OBJECT-TYPE    
  TimeTicks  

powerNetSoftwareConfig 1.3.6.1.4.1.318.1.2.1.2
OBJECT IDENTIFIER    

powerNetSoftwareTableSize 1.3.6.1.4.1.318.1.2.1.2.1
The number of software modules supporting the UPS.
OBJECT-TYPE    
  INTEGER  

powerNetSoftwareTable 1.3.6.1.4.1.318.1.2.1.2.2
A list of the software monitoring the UPS.
OBJECT-TYPE    
  SEQUENCE OF  
    PowerNetSoftwareEntry

powerNetSoftwareEntry 1.3.6.1.4.1.318.1.2.1.2.2.1
An entry containing information on a software module.
OBJECT-TYPE    
  PowerNetSoftwareEntry  

moduleNumber 1.3.6.1.4.1.318.1.2.1.2.2.1.1
The index into the Software Entry Table
OBJECT-TYPE    
  INTEGER  

moduleName 1.3.6.1.4.1.318.1.2.1.2.2.1.2
The name of the software module.
OBJECT-TYPE    
  DisplayString SIZE(0..79)  

moduleVersion 1.3.6.1.4.1.318.1.2.1.2.2.1.3
The version of the software module.
OBJECT-TYPE    
  DisplayString SIZE(0..8)  

moduleDate 1.3.6.1.4.1.318.1.2.1.2.2.1.4
The date of the software module represented as mm-dd-yy.
OBJECT-TYPE    
  DisplayString SIZE(0..9)  

system 1.3.6.1.4.1.318.1.3
OBJECT IDENTIFIER    

backUPS 1.3.6.1.4.1.318.1.3.1
OBJECT IDENTIFIER    

smartUPS 1.3.6.1.4.1.318.1.3.2
OBJECT IDENTIFIER    

smartUPS250 1.3.6.1.4.1.318.1.3.2.1
OBJECT IDENTIFIER    

smartUPS400 1.3.6.1.4.1.318.1.3.2.2
OBJECT IDENTIFIER    

smartUPS600 1.3.6.1.4.1.318.1.3.2.3
OBJECT IDENTIFIER    

smartUPS900 1.3.6.1.4.1.318.1.3.2.4
OBJECT IDENTIFIER    

smartUPS1250 1.3.6.1.4.1.318.1.3.2.5
OBJECT IDENTIFIER    

smartUPS2000 1.3.6.1.4.1.318.1.3.2.6
OBJECT IDENTIFIER    

smartUPS450 1.3.6.1.4.1.318.1.3.2.7
OBJECT IDENTIFIER    

smartUPS700 1.3.6.1.4.1.318.1.3.2.8
OBJECT IDENTIFIER    

smartUPS1000 1.3.6.1.4.1.318.1.3.2.9
OBJECT IDENTIFIER    

smartUPS1400 1.3.6.1.4.1.318.1.3.2.10
OBJECT IDENTIFIER    

smartUPS2200 1.3.6.1.4.1.318.1.3.2.11
OBJECT IDENTIFIER    

smartUPS3000 1.3.6.1.4.1.318.1.3.2.12
OBJECT IDENTIFIER    

smartUPS5000 1.3.6.1.4.1.318.1.3.2.13
OBJECT IDENTIFIER    

smartUPS7500 1.3.6.1.4.1.318.1.3.2.14
OBJECT IDENTIFIER    

smartUPS10000 1.3.6.1.4.1.318.1.3.2.15
OBJECT IDENTIFIER    

smartUPS1500 1.3.6.1.4.1.318.1.3.2.16
OBJECT IDENTIFIER    

smartUPS3000DSP 1.3.6.1.4.1.318.1.3.2.17
OBJECT IDENTIFIER    

smartUPS5000DSP 1.3.6.1.4.1.318.1.3.2.18
OBJECT IDENTIFIER    

smartUPS8000 1.3.6.1.4.1.318.1.3.2.19
OBJECT IDENTIFIER    

matrixUPS 1.3.6.1.4.1.318.1.3.3
OBJECT IDENTIFIER    

matrixUPS3000 1.3.6.1.4.1.318.1.3.3.1
OBJECT IDENTIFIER    

matrixUPS5000 1.3.6.1.4.1.318.1.3.3.2
OBJECT IDENTIFIER    

masterSwitch 1.3.6.1.4.1.318.1.3.4
OBJECT IDENTIFIER    

masterSwitchV1 1.3.6.1.4.1.318.1.3.4.1
OBJECT IDENTIFIER    

masterSwitchV2 1.3.6.1.4.1.318.1.3.4.2
OBJECT IDENTIFIER    

masterSwitchVM 1.3.6.1.4.1.318.1.3.4.3
OBJECT IDENTIFIER    

masterSwitchMSP 1.3.6.1.4.1.318.1.3.4.4
OBJECT IDENTIFIER    

masterSwitchrPDU 1.3.6.1.4.1.318.1.3.4.5
OBJECT IDENTIFIER    

masterSwitchrPDU2 1.3.6.1.4.1.318.1.3.4.6
OBJECT IDENTIFIER    

symmetraUPS 1.3.6.1.4.1.318.1.3.5
OBJECT IDENTIFIER    

symmetraUPS4kVA 1.3.6.1.4.1.318.1.3.5.1
OBJECT IDENTIFIER    

symmetraUPS8kVA 1.3.6.1.4.1.318.1.3.5.2
OBJECT IDENTIFIER    

symmetraUPS12kVA 1.3.6.1.4.1.318.1.3.5.3
OBJECT IDENTIFIER    

symmetraUPS16kVA 1.3.6.1.4.1.318.1.3.5.4
OBJECT IDENTIFIER    

dp100E 1.3.6.1.4.1.318.1.3.6
OBJECT IDENTIFIER    

dp300E 1.3.6.1.4.1.318.1.3.7
OBJECT IDENTIFIER    

monitors 1.3.6.1.4.1.318.1.3.8
OBJECT IDENTIFIER    

environmental 1.3.6.1.4.1.318.1.3.8.1
OBJECT IDENTIFIER    

environmentalMgtSystem 1.3.6.1.4.1.318.1.3.8.2
OBJECT IDENTIFIER    

emu2 1.3.6.1.4.1.318.1.3.8.3
OBJECT IDENTIFIER    

mem 1.3.6.1.4.1.318.1.3.8.4
OBJECT IDENTIFIER    

redundantSwitch 1.3.6.1.4.1.318.1.3.9
OBJECT IDENTIFIER    

dcPower 1.3.6.1.4.1.318.1.3.10
OBJECT IDENTIFIER    

dm3 1.3.6.1.4.1.318.1.3.10.1
OBJECT IDENTIFIER    

dcmim2 1.3.6.1.4.1.318.1.3.10.2
OBJECT IDENTIFIER    

automaticXferSwitch 1.3.6.1.4.1.318.1.3.11
OBJECT IDENTIFIER    

netLock 1.3.6.1.4.1.318.1.3.12
OBJECT IDENTIFIER    

symmetra3PhaseUPS 1.3.6.1.4.1.318.1.3.13
OBJECT IDENTIFIER    

symmetra3PhaseUPS40kVA 1.3.6.1.4.1.318.1.3.13.1
OBJECT IDENTIFIER    

symmetra3PhaseUPS60kVA 1.3.6.1.4.1.318.1.3.13.2
OBJECT IDENTIFIER    

symmetra3PhaseUPS80kVA 1.3.6.1.4.1.318.1.3.13.3
OBJECT IDENTIFIER    

symmetra3PhaseUPS20kVA 1.3.6.1.4.1.318.1.3.13.4
OBJECT IDENTIFIER    

networkAir 1.3.6.1.4.1.318.1.3.14
OBJECT IDENTIFIER    

airFMSeries 1.3.6.1.4.1.318.1.3.14.1
OBJECT IDENTIFIER    

rackAirRemovalUnit 1.3.6.1.4.1.318.1.3.14.2
OBJECT IDENTIFIER    

airPASeries 1.3.6.1.4.1.318.1.3.14.3
OBJECT IDENTIFIER    

airIRSC100Series 1.3.6.1.4.1.318.1.3.14.4
OBJECT IDENTIFIER    

airIRRC100Series 1.3.6.1.4.1.318.1.3.14.5
OBJECT IDENTIFIER    

airIRRP100Series 1.3.6.1.4.1.318.1.3.14.6
OBJECT IDENTIFIER    

airIRRP500Series 1.3.6.1.4.1.318.1.3.14.7
OBJECT IDENTIFIER    

airIRRD100Series 1.3.6.1.4.1.318.1.3.14.8
OBJECT IDENTIFIER    

airInRoomPerimeter 1.3.6.1.4.1.318.1.3.14.9
OBJECT IDENTIFIER    

infraStruXurePDU 1.3.6.1.4.1.318.1.3.15
OBJECT IDENTIFIER    

ais5000UPS 1.3.6.1.4.1.318.1.3.16
OBJECT IDENTIFIER    

ais5000UPS10kVA 1.3.6.1.4.1.318.1.3.16.1
OBJECT IDENTIFIER    

ais5000UPS20kVA 1.3.6.1.4.1.318.1.3.16.2
OBJECT IDENTIFIER    

ais5000UPS30kVA 1.3.6.1.4.1.318.1.3.16.3
OBJECT IDENTIFIER    

ais5000UPS40kVA 1.3.6.1.4.1.318.1.3.16.4
OBJECT IDENTIFIER    

ais5000UPS60kVA 1.3.6.1.4.1.318.1.3.16.5
OBJECT IDENTIFIER    

ais5000UPS80kVA 1.3.6.1.4.1.318.1.3.16.6
OBJECT IDENTIFIER    

ais5000UPS100kVA 1.3.6.1.4.1.318.1.3.16.7
OBJECT IDENTIFIER    

smartUPS3Phase 1.3.6.1.4.1.318.1.3.17
OBJECT IDENTIFIER    

smartUPS3Phase10kVA 1.3.6.1.4.1.318.1.3.17.1
OBJECT IDENTIFIER    

smartUPS3Phase15kVA 1.3.6.1.4.1.318.1.3.17.2
OBJECT IDENTIFIER    

smartUPS3Phase20kVA 1.3.6.1.4.1.318.1.3.17.3
OBJECT IDENTIFIER    

smartUPS3Phase30kVA 1.3.6.1.4.1.318.1.3.17.4
OBJECT IDENTIFIER    

smartUPS3Phase40kVA 1.3.6.1.4.1.318.1.3.17.5
OBJECT IDENTIFIER    

battManager 1.3.6.1.4.1.318.1.3.18
OBJECT IDENTIFIER    

infraStruXureATS 1.3.6.1.4.1.318.1.3.19
OBJECT IDENTIFIER    

conPortServ 1.3.6.1.4.1.318.1.3.20
OBJECT IDENTIFIER    

conPortServAP930x 1.3.6.1.4.1.318.1.3.20.1
OBJECT IDENTIFIER    

gutor 1.3.6.1.4.1.318.1.3.21
OBJECT IDENTIFIER    

gutorPEW 1.3.6.1.4.1.318.1.3.21.1
OBJECT IDENTIFIER    

gutorPDW 1.3.6.1.4.1.318.1.3.21.2
OBJECT IDENTIFIER    

gutorWEW 1.3.6.1.4.1.318.1.3.21.3
OBJECT IDENTIFIER    

gutorWDW 1.3.6.1.4.1.318.1.3.21.4
OBJECT IDENTIFIER    

gutorSDC 1.3.6.1.4.1.318.1.3.21.5
OBJECT IDENTIFIER    

accControl 1.3.6.1.4.1.318.1.3.22
OBJECT IDENTIFIER    

accPX 1.3.6.1.4.1.318.1.3.22.1
OBJECT IDENTIFIER    

symmetraPX 1.3.6.1.4.1.318.1.3.23
OBJECT IDENTIFIER    

symmetraPx48kVA 1.3.6.1.4.1.318.1.3.23.1
OBJECT IDENTIFIER    

symmetraPx160kVA 1.3.6.1.4.1.318.1.3.23.2
OBJECT IDENTIFIER    

symmetraPx250kVA 1.3.6.1.4.1.318.1.3.23.3
OBJECT IDENTIFIER    

symmetraPx500kVA 1.3.6.1.4.1.318.1.3.23.4
OBJECT IDENTIFIER    

symmetraPx100kVA 1.3.6.1.4.1.318.1.3.23.5
OBJECT IDENTIFIER    

symmetraPxDisplay 1.3.6.1.4.1.318.1.3.23.6
OBJECT IDENTIFIER    

isxModDistribution 1.3.6.1.4.1.318.1.3.24
OBJECT IDENTIFIER    

isx24ModuleHalfRackPdu 1.3.6.1.4.1.318.1.3.24.1
OBJECT IDENTIFIER    

isx6ModuleRackPdu 1.3.6.1.4.1.318.1.3.24.2
OBJECT IDENTIFIER    

isxServers 1.3.6.1.4.1.318.1.3.25
OBJECT IDENTIFIER    

isxcBasic 1.3.6.1.4.1.318.1.3.25.1
OBJECT IDENTIFIER    

isxcStandard 1.3.6.1.4.1.318.1.3.25.2
OBJECT IDENTIFIER    

isxcEnterprise 1.3.6.1.4.1.318.1.3.25.3
OBJECT IDENTIFIER    

isxcVirtual 1.3.6.1.4.1.318.1.3.25.4
OBJECT IDENTIFIER    

smartUPS2 1.3.6.1.4.1.318.1.3.27
OBJECT IDENTIFIER    

galaxy 1.3.6.1.4.1.318.1.3.28
OBJECT IDENTIFIER    

galaxy7000UPS200kVA 1.3.6.1.4.1.318.1.3.28.1
OBJECT IDENTIFIER    

galaxy7000UPS250kVA 1.3.6.1.4.1.318.1.3.28.2
OBJECT IDENTIFIER    

galaxy7000UPS300kVA 1.3.6.1.4.1.318.1.3.28.3
OBJECT IDENTIFIER    

galaxy7000UPS400kVA 1.3.6.1.4.1.318.1.3.28.4
OBJECT IDENTIFIER    

galaxy7000UPS500kVA 1.3.6.1.4.1.318.1.3.28.5
OBJECT IDENTIFIER    

galaxy7000SSC800kVA 1.3.6.1.4.1.318.1.3.28.6
OBJECT IDENTIFIER    

galaxy7000SSC1200kVA 1.3.6.1.4.1.318.1.3.28.7
OBJECT IDENTIFIER    

galaxy7000SSC2000kVA 1.3.6.1.4.1.318.1.3.28.8
OBJECT IDENTIFIER    

galaxy300UPS10kVA33 1.3.6.1.4.1.318.1.3.28.9
OBJECT IDENTIFIER    

galaxy300UPS15kVA33 1.3.6.1.4.1.318.1.3.28.10
OBJECT IDENTIFIER    

galaxy300UPS20kVA33 1.3.6.1.4.1.318.1.3.28.11
OBJECT IDENTIFIER    

galaxy300UPS30kVA33 1.3.6.1.4.1.318.1.3.28.12
OBJECT IDENTIFIER    

galaxy300UPS40kVA33 1.3.6.1.4.1.318.1.3.28.13
OBJECT IDENTIFIER    

galaxy300UPS10kVA31 1.3.6.1.4.1.318.1.3.28.14
OBJECT IDENTIFIER    

galaxy300UPS15kVA31 1.3.6.1.4.1.318.1.3.28.15
OBJECT IDENTIFIER    

galaxy300UPS20kVA31 1.3.6.1.4.1.318.1.3.28.16
OBJECT IDENTIFIER    

galaxy300UPS30kVA31 1.3.6.1.4.1.318.1.3.28.17
OBJECT IDENTIFIER    

galaxy5000UPS20KVA 1.3.6.1.4.1.318.1.3.28.18
OBJECT IDENTIFIER    

galaxy5000UPS30KVA 1.3.6.1.4.1.318.1.3.28.19
OBJECT IDENTIFIER    

galaxy5000UPS40KVA 1.3.6.1.4.1.318.1.3.28.20
OBJECT IDENTIFIER    

galaxy5000UPS50KVA 1.3.6.1.4.1.318.1.3.28.21
OBJECT IDENTIFIER    

galaxy5000UPS60KVA 1.3.6.1.4.1.318.1.3.28.22
OBJECT IDENTIFIER    

galaxy5000UPS80KVA 1.3.6.1.4.1.318.1.3.28.23
OBJECT IDENTIFIER    

galaxy5000UPS100KVA 1.3.6.1.4.1.318.1.3.28.24
OBJECT IDENTIFIER    

galaxy5000UPS120KVA 1.3.6.1.4.1.318.1.3.28.25
OBJECT IDENTIFIER    

galaxy5000UPS130KVA 1.3.6.1.4.1.318.1.3.28.26
OBJECT IDENTIFIER    

galaxy5500UPS20KVA 1.3.6.1.4.1.318.1.3.28.27
OBJECT IDENTIFIER    

galaxy5500UPS30KVA 1.3.6.1.4.1.318.1.3.28.28
OBJECT IDENTIFIER    

galaxy5500UPS40KVA 1.3.6.1.4.1.318.1.3.28.29
OBJECT IDENTIFIER    

galaxy5500UPS50KVA 1.3.6.1.4.1.318.1.3.28.30
OBJECT IDENTIFIER    

galaxy5500UPS60KVA 1.3.6.1.4.1.318.1.3.28.31
OBJECT IDENTIFIER    

galaxy5500UPS80KVA 1.3.6.1.4.1.318.1.3.28.32
OBJECT IDENTIFIER    

galaxy5500UPS100KVA 1.3.6.1.4.1.318.1.3.28.33
OBJECT IDENTIFIER    

galaxy5500UPS120KVA 1.3.6.1.4.1.318.1.3.28.34
OBJECT IDENTIFIER    

galaxy5500UPS130KVA 1.3.6.1.4.1.318.1.3.28.35
OBJECT IDENTIFIER    

galaxy9000UPS 1.3.6.1.4.1.318.1.3.28.48
OBJECT IDENTIFIER    

galaxy9000SSC 1.3.6.1.4.1.318.1.3.28.49
OBJECT IDENTIFIER    

galaxy9000UPSWithSSC 1.3.6.1.4.1.318.1.3.28.50
OBJECT IDENTIFIER    

galaxy9000FreqConverter 1.3.6.1.4.1.318.1.3.28.51
OBJECT IDENTIFIER    

eps 1.3.6.1.4.1.318.1.3.30
OBJECT IDENTIFIER    

eps6000UPS 1.3.6.1.4.1.318.1.3.30.1
OBJECT IDENTIFIER    

eps6000SSC 1.3.6.1.4.1.318.1.3.30.2
OBJECT IDENTIFIER    

eps6000UPSWithSSC 1.3.6.1.4.1.318.1.3.30.3
OBJECT IDENTIFIER    

eps6000FreqConverter 1.3.6.1.4.1.318.1.3.30.4
OBJECT IDENTIFIER    

eps7000UPS 1.3.6.1.4.1.318.1.3.30.5
OBJECT IDENTIFIER    

eps7000SSC 1.3.6.1.4.1.318.1.3.30.6
OBJECT IDENTIFIER    

eps7000UPSWithSSC 1.3.6.1.4.1.318.1.3.30.7
OBJECT IDENTIFIER    

eps7000FreqConverter 1.3.6.1.4.1.318.1.3.30.8
OBJECT IDENTIFIER    

eps8000UPS 1.3.6.1.4.1.318.1.3.30.9
OBJECT IDENTIFIER    

eps8000SSC 1.3.6.1.4.1.318.1.3.30.10
OBJECT IDENTIFIER    

eps8000UPSWithSSC 1.3.6.1.4.1.318.1.3.30.11
OBJECT IDENTIFIER    

eps8000FreqConverter 1.3.6.1.4.1.318.1.3.30.12
OBJECT IDENTIFIER    

experimental 1.3.6.1.4.1.318.1.4
OBJECT IDENTIFIER    

apcmgmt 1.3.6.1.4.1.318.2
OBJECT IDENTIFIER    

upsOverload 1.3.6.1.4.1.318.2
SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.
TRAP-TYPE    
  mtrapargsString  

mconfig 1.3.6.1.4.1.318.2.1
OBJECT IDENTIFIER    

mconfigNumTrapReceivers 1.3.6.1.4.1.318.2.1.1
The number of managers to send traps to.
OBJECT-TYPE    
  INTEGER  

mconfigTrapReceiverTable 1.3.6.1.4.1.318.2.1.2
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers. Maximum number of Trap Receivers is four.
OBJECT-TYPE    
  SEQUENCE OF  
    MconfigTrapReceiverEntry

mconfigTrapReceiverEntry 1.3.6.1.4.1.318.2.1.2.1
The managers to send traps to.
OBJECT-TYPE    
  MconfigTrapReceiverEntry  

trapIndex 1.3.6.1.4.1.318.2.1.2.1.1
The index to a trap receiver entry.
OBJECT-TYPE    
  INTEGER  

receiverAddr 1.3.6.1.4.1.318.2.1.2.1.2
The IP address of the manager to send a trap to.
OBJECT-TYPE    
  IpAddress  

communityString 1.3.6.1.4.1.318.2.1.2.1.3
The community name to use in the trap when sent to the manager.
OBJECT-TYPE    
  DisplayString  

severity 1.3.6.1.4.1.318.2.1.2.1.4
The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager.
OBJECT-TYPE    
  INTEGER information(1), warning(2), severe(3)  

acceptThisReceiver 1.3.6.1.4.1.318.2.1.2.1.5
The value of yes(1) indicates that trap generation for this manager is enabled. The value of no(2) indicates that trap generation for this manager is disabled
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

receiveTrapType 1.3.6.1.4.1.318.2.1.2.1.6
Type of trap.
OBJECT-TYPE    
  INTEGER powernet(1), ietf(2), both(3)  

mconfigBOOTPEnabled 1.3.6.1.4.1.318.2.1.3
The value of yes(1) indicates the PowerNet Adapter is configured to obtain its IP configuration parameters from a BOOTP server. The value of no(2) indicates adapter will assume IP configuration parameters values saved in adapter's eeprom, which was originally configured at local console.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

mconfigTFTPServerIP 1.3.6.1.4.1.318.2.1.4
The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address is provided by BOOTP server and not allowed to be modified; otherwise, this IP address can be modified. Before using TFTP to load new code image, the image file should be placed in proper directory of the specified TFTP server. This OID is only supported by APC Network Management Cards.
OBJECT-TYPE    
  IpAddress  

newCodeAuthentViaTFTP 1.3.6.1.4.1.318.2.1.5
Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will start to load the remote image file, for authentication only, instead of saving the code into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot the PowerNet adapter and invoke the loader to load and save new code into the flash memory. Otherwise, the current agent code will continue to run. This OID shows the result of the above authentication process. validNewAgentCodeImage (1) means the code image on TFTP server is a valid APC agent code and is different version from the current agent. Once agent identifies this, loader will start to update flash memory with the new agent code. sameAgentCodeImage (2) means the code image on TFTP server is exactly the same as the currently running agent. Currently running agent will not invoke loader to load the same again. invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid APC agent code. Thus, current agent will not load it into the flash memory. The value of this OID will be associated with TRAP codeImageAuthentDone. This OID is only supported by APC Network Management Cards.
OBJECT-TYPE    
  INTEGER unknown(1), validNewAgentCodeImage(2), sameAgentCodeImage(3), invalidAgentCodeImage(4)  

mconfigClock 1.3.6.1.4.1.318.2.1.6
OBJECT IDENTIFIER    

mconfigClockDate 1.3.6.1.4.1.318.2.1.6.1
The current date in the mm/dd/yyyy format. Example: 01/01/2000.
OBJECT-TYPE    
  DisplayString  

mconfigClockTime 1.3.6.1.4.1.318.2.1.6.2
The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am.
OBJECT-TYPE    
  DisplayString  

mcontrol 1.3.6.1.4.1.318.2.2
OBJECT IDENTIFIER    

mcontrolRestartAgent 1.3.6.1.4.1.318.2.2.1
Setting this OID to restartCurrentAgent (1) will restart the same SNMP agent code currently saved in flash memory. Setting this OID to loadAndExecuteNewAgent (3) will enable adapter to load a new agent code into the flash memory and start to execute this new agent code. Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only supported by APC Network Management Cards. Setting this OID to restartWithoutAgent (4) will restart the system and not start the agent. The subsequent time the system restarts the agent will also automatically restart. Setting this OID to resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system. Setting this OID to resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the current setting, set the IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system.
OBJECT-TYPE    
  INTEGER restartCurrentAgent(1), continueCurrentAgent(2), loadAndExecuteNewAgent(3), restartWithoutAgent(4), resetNetworkAndRestart(5), resetNetworkLeaveModeAndRestart(6)  

mtrapargs 1.3.6.1.4.1.318.2.3
OBJECT IDENTIFIER    

mtrapargsInteger 1.3.6.1.4.1.318.2.3.1
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsIpAddress 1.3.6.1.4.1.318.2.3.2
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
OBJECT-TYPE    
  IpAddress  

mtrapargsString 1.3.6.1.4.1.318.2.3.3
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsGauge 1.3.6.1.4.1.318.2.3.4
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  Gauge  

mtrapargsTimeTicks 1.3.6.1.4.1.318.2.3.5
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  TimeTicks  

mtrapargsInteger02 1.3.6.1.4.1.318.2.3.6
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsInteger03 1.3.6.1.4.1.318.2.3.7
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsIpAddress02 1.3.6.1.4.1.318.2.3.8
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
OBJECT-TYPE    
  IpAddress  

mtrapargsIpAddress03 1.3.6.1.4.1.318.2.3.9
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
OBJECT-TYPE    
  IpAddress  

mtrapargsString02 1.3.6.1.4.1.318.2.3.10
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsString03 1.3.6.1.4.1.318.2.3.11
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsGauge02 1.3.6.1.4.1.318.2.3.12
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  Gauge  

mtrapargsGauge03 1.3.6.1.4.1.318.2.3.13
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  Gauge  

mtrapargsTimeTicks02 1.3.6.1.4.1.318.2.3.14
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  TimeTicks  

mtrapargsTimeTicks03 1.3.6.1.4.1.318.2.3.15
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  TimeTicks  

mtrapargsString04 1.3.6.1.4.1.318.2.3.16
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsString05 1.3.6.1.4.1.318.2.3.17
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsInteger04 1.3.6.1.4.1.318.2.3.18
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsInteger05 1.3.6.1.4.1.318.2.3.19
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsString06 1.3.6.1.4.1.318.2.3.20
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsString07 1.3.6.1.4.1.318.2.3.21
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsString08 1.3.6.1.4.1.318.2.3.22
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsOctetString 1.3.6.1.4.1.318.2.3.23
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString02 1.3.6.1.4.1.318.2.3.24
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString03 1.3.6.1.4.1.318.2.3.25
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString04 1.3.6.1.4.1.318.2.3.26
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString05 1.3.6.1.4.1.318.2.3.27
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString06 1.3.6.1.4.1.318.2.3.28
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString07 1.3.6.1.4.1.318.2.3.29
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mtrapargsOctetString08 1.3.6.1.4.1.318.2.3.30
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  OCTET STRING  

mfiletransfer 1.3.6.1.4.1.318.2.4
OBJECT IDENTIFIER    

mfiletransferStatus 1.3.6.1.4.1.318.2.4.1
OBJECT IDENTIFIER    

mfiletransferStatusLastTransferResult 1.3.6.1.4.1.318.2.4.1.1
This OID has been deprecated. Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP server. This OID shows the last attempted file transfer result. lastFileTransferResultSuccessful (1) means the file transfer was successful. lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers. lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason. lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network. lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access. lastFileTransferResultFailureFileNotFound (6) means that the file could not be located. lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown. lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt.
OBJECT-TYPE    
  INTEGER lastFileTransferResultSuccessful(1), lastFileTransferResultNotAvailable(2), lastFileTransferResultFailureUnknown(3), lastFileTransferResultFailureServerInaccessible(4), lastFileTransferResultFailureServerAccessDenied(5), lastFileTransferResultFailureFileNotFound(6), lastFileTransferResultFailureFileTypeUnknown(7), lastFileTransferResultFailureFileCorrupted(8)  

mfiletransferConfig 1.3.6.1.4.1.318.2.4.2
OBJECT IDENTIFIER    

mfiletransferConfigSettings 1.3.6.1.4.1.318.2.4.2.1
OBJECT IDENTIFIER    

mfiletransferConfigSettingsFilename 1.3.6.1.4.1.318.2.4.2.1.1
This OID has been deprecated. The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID. If the file to transfer exists in the default server directory then the path may be omitted.
OBJECT-TYPE    
  DisplayString  

mfiletransferConfigTFTP 1.3.6.1.4.1.318.2.4.2.2
OBJECT IDENTIFIER    

mfiletransferConfigTFTPServerAddress 1.3.6.1.4.1.318.2.4.2.2.1
This OID has been deprecated. The IP Address in dotted decimal notation of the TFTP server involved in the file transfer.
OBJECT-TYPE    
  DisplayString  

mfiletransferConfigFTP 1.3.6.1.4.1.318.2.4.2.3
OBJECT IDENTIFIER    

mfiletransferConfigFTPServerAddress 1.3.6.1.4.1.318.2.4.2.3.1
This OID has been deprecated. The IP Address in dotted decimal notation of the FTP server involved in the file transfer.
OBJECT-TYPE    
  DisplayString  

mfiletransferConfigFTPServerUser 1.3.6.1.4.1.318.2.4.2.3.2
This OID has been deprecated. The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress.
OBJECT-TYPE    
  DisplayString  

mfiletransferConfigFTPServerPassword 1.3.6.1.4.1.318.2.4.2.3.3
This OID has been deprecated. The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress.
OBJECT-TYPE    
  DisplayString  

mfiletransferControl 1.3.6.1.4.1.318.2.4.3
OBJECT IDENTIFIER    

mfiletransferControlInitiateFileTransfer 1.3.6.1.4.1.318.2.4.3.1
This OID has been deprecated. Setting this OID to doNotInitiateFileTransfer (1) will do nothing. Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress. Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process.
OBJECT-TYPE    
  INTEGER doNotInitiateFileTransfer(1), initiateFileTransferDownloadViaTFTP(2), initiateFileTransferDownloadViaFTP(3)  

upsDiagnosticsFailed 1.3.6.1.4.1.318.3
SEVERE: The UPS failed its internal diagnostic self-test.
TRAP-TYPE    
  mtrapargsString  

upsDischarged 1.3.6.1.4.1.318.4
SEVERE: The UPS batteries are discharged; if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot be guaranteed.
TRAP-TYPE    
  mtrapargsString  

upsOnBattery 1.3.6.1.4.1.318.5
WARNING: The UPS has switched to battery backup power.
TRAP-TYPE    
  mtrapargsString  

smartBoostOn 1.3.6.1.4.1.318.6
WARNING: The UPS has enabled SmartBoost(TM).
TRAP-TYPE    
  mtrapargsString  

lowBattery 1.3.6.1.4.1.318.7
SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load.
TRAP-TYPE    
  mtrapargsString  

communicationEstablished 1.3.6.1.4.1.318.8
INFORMATIONAL: Communication with the UPS has been established.
TRAP-TYPE    
  mtrapargsString  

powerRestored 1.3.6.1.4.1.318.9
INFORMATIONAL: Utility power has been restored.
TRAP-TYPE    
  mtrapargsString  

upsDiagnosticsPassed 1.3.6.1.4.1.318.10
INFORMATIONAL: The UPS passed its internal self-test.
TRAP-TYPE    
  mtrapargsString  

returnFromLowBattery 1.3.6.1.4.1.318.11
INFORMATIONAL: The UPS has returned from a low battery condition.
TRAP-TYPE    
  mtrapargsString  

upsTurnedOff 1.3.6.1.4.1.318.12
WARNING: The UPS has been turned 'off' by the management station.
TRAP-TYPE    
  mtrapargsString  

upsSleeping 1.3.6.1.4.1.318.13
WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off.
TRAP-TYPE    
  mtrapargsString  

upsWokeUp 1.3.6.1.4.1.318.14
INFORMATION: The UPS has returned from 'sleep' mode. Power to the load has been restored.
TRAP-TYPE    
  mtrapargsString  

upsRebootStarted 1.3.6.1.4.1.318.15
WARNING: The UPS has started its reboot sequence. The UPS will reboot itself at this time.
TRAP-TYPE    
  mtrapargsString  

upsDipSwitchChanged 1.3.6.1.4.1.318.16
WARNING: The dip switch settings on the UPS have been changed, possibly altering UPS performance.
TRAP-TYPE    
  mtrapargsString  

upsBatteryNeedsReplacement 1.3.6.1.4.1.318.17
SEVERE: The batteries of the UPS need immediate replacement.
TRAP-TYPE    
  mtrapargsString  

contactFault 1.3.6.1.4.1.318.18
SEVERE: One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

contactFaultResolved 1.3.6.1.4.1.318.19
INFORMATIONAL: A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

hardwareFailureBypass 1.3.6.1.4.1.318.20
SEVERE: UPS on bypass due to internal fault
TRAP-TYPE    
  mtrapargsString  

softwareBypass 1.3.6.1.4.1.318.21
WARNING: UPS on bypass - user set via software or panel
TRAP-TYPE    
  mtrapargsString  

switchedBypass 1.3.6.1.4.1.318.22
WARNING: UPS on bypass - initiated by user
TRAP-TYPE    
  mtrapargsString  

returnFromBypass 1.3.6.1.4.1.318.23
INFORMATIONAL: UPS has returned from bypass
TRAP-TYPE    
  mtrapargsString  

bypassPowerSupplyFailure 1.3.6.1.4.1.318.24
SEVERE: Base module bypass power supply needs repair
TRAP-TYPE    
  mtrapargsString  

baseFanFailure 1.3.6.1.4.1.318.25
SEVERE: Base module fan needs repair
TRAP-TYPE    
  mtrapargsString  

batteryPackCommLost 1.3.6.1.4.1.318.26
SEVERE: Check installation of external battery packs signal cable
TRAP-TYPE    
  mtrapargsString  

batteryPackCommEstablished 1.3.6.1.4.1.318.27
INFORMATIONAL: UPS is communicating with the external battery packs.
TRAP-TYPE    
  mtrapargsString  

calibrationStart 1.3.6.1.4.1.318.28
INFORMATIONAL: A battery calibration test has been initiated on the UPS.
TRAP-TYPE    
  mtrapargsString  

restartAgent 1.3.6.1.4.1.318.29
INFORMATIONAL: Agent restarting as commanded by manager.
TRAP-TYPE    
  mtrapargsString  

upsTurnedOn 1.3.6.1.4.1.318.30
INFORMATIONAL: A UPS is turned on.
TRAP-TYPE    
  mtrapargsString  

smartAvrReducing 1.3.6.1.4.1.318.31
WARNING: The UPS is reducing the line voltage via SmartTrim(TM).
TRAP-TYPE    
  mtrapargsString  

codeAuthenticationDone 1.3.6.1.4.1.318.32
INFORMATIONAL: Authentication on agent code image is done.
TRAP-TYPE    
  mconfigTFTPServerIP  
  newCodeAuthentViaTFTP  

upsOverloadCleared 1.3.6.1.4.1.318.33
INFORMATIONAL: The overload condition has been cleared.
TRAP-TYPE    
  mtrapargsString  

smartBoostOff 1.3.6.1.4.1.318.34
INFORMATIONAL: The UPS has returned from SmartBoost(TM).
TRAP-TYPE    
  mtrapargsString  

smartAvrReducingOff 1.3.6.1.4.1.318.35
INFORMATIONAL: The UPS has returned from SmartTrim(TM).
TRAP-TYPE    
  mtrapargsString  

upsBatteryReplaced 1.3.6.1.4.1.318.36
INFORMATIONAL: A bad battery fault has been cleared.
TRAP-TYPE    
  mtrapargsString  

calibrationEnd 1.3.6.1.4.1.318.37
INFORMATIONAL: The UPS has finished calibrating.
TRAP-TYPE    
  mtrapargsString  

dischargeCleared 1.3.6.1.4.1.318.38
INFORMATIONAL: A UPS discharge condition has been cleared.
TRAP-TYPE    
  mtrapargsString  

gracefulShutdown 1.3.6.1.4.1.318.39
INFORMATIONAL: A graceful shutdown has been initiated.
TRAP-TYPE    
  mtrapargsString  

outletOn 1.3.6.1.4.1.318.41
WARNING: The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on.
TRAP-TYPE    
  sPDUOutletControlIndex  

outletOff 1.3.6.1.4.1.318.42
WARNING: The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off.
TRAP-TYPE    
  sPDUOutletControlIndex  

outletReboot 1.3.6.1.4.1.318.43
WARNING: The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted.
TRAP-TYPE    
  sPDUOutletControlIndex  

configChangeSNMP 1.3.6.1.4.1.318.44
WARNING: The SNMP configuration has been changed.
TRAP-TYPE    
  mtrapargsString  

configChangeOutlet 1.3.6.1.4.1.318.45
WARNING: The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration.
TRAP-TYPE    
  sPDUOutletConfigIndex  

accessViolationConsole 1.3.6.1.4.1.318.46
WARNING: Someone has attempted to login via the console with the incorrect password.
TRAP-TYPE    
  mtrapargsString  

accessViolationHTTP 1.3.6.1.4.1.318.47
WARNING: Someone has attempted to login via HTTP with the incorrect password.
TRAP-TYPE    
  mtrapargsString  

passwordChange 1.3.6.1.4.1.318.48
WARNING: The password for the device has been changed.
TRAP-TYPE    
  mtrapargsString  

badVoltage 1.3.6.1.4.1.318.49
WARNING: The output voltage is not within acceptable range.
TRAP-TYPE    
  mtrapargsString  

badVoltageCleared 1.3.6.1.4.1.318.50
INFORMATIONAL: The output voltage has returned to an acceptable level.
TRAP-TYPE    
  mtrapargsString  

chargerFailure 1.3.6.1.4.1.318.51
WARNING: The battery charger has failed.
TRAP-TYPE    
  mtrapargsString  

chargerFailureCleared 1.3.6.1.4.1.318.52
INFORMATIONAL: The battery charger failure condition has been cleared.
TRAP-TYPE    
  mtrapargsString  

batteryOverTemperature 1.3.6.1.4.1.318.53
WARNING: The battery temperature threshold has been violated.
TRAP-TYPE    
  mtrapargsString  

batteryOverTemperatureCleared 1.3.6.1.4.1.318.54
INFORMATIONAL: The battery over temperature has been cleared.
TRAP-TYPE    
  mtrapargsString  

smartRelayFault 1.3.6.1.4.1.318.55
WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault.
TRAP-TYPE    
  mtrapargsString  

smartRelayFaultCleared 1.3.6.1.4.1.318.56
INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared.
TRAP-TYPE    
  mtrapargsString  

humidityThresholdViolation1 1.3.6.1.4.1.318.57
SEVERE: Probe 1 humidity threshold violated. The first variable is the current humidity.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

humidityThresholdViolationCleared1 1.3.6.1.4.1.318.58
INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1.
TRAP-TYPE    
  mtrapargsString  

temperatureThresholdViolation1 1.3.6.1.4.1.318.59
SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

temperatureThresholdViolationCleared1 1.3.6.1.4.1.318.60
INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1.
TRAP-TYPE    
  mtrapargsString  

humidityThresholdViolation2 1.3.6.1.4.1.318.61
SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

humidityThresholdViolationCleared2 1.3.6.1.4.1.318.62
INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2.
TRAP-TYPE    
  mtrapargsString  

temperatureThresholdViolation2 1.3.6.1.4.1.318.63
SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

temperatureThresholdViolationCleared2 1.3.6.1.4.1.318.64
INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2.
TRAP-TYPE    
  mtrapargsString  

mupsCommunicationEstablished 1.3.6.1.4.1.318.65
INFORMATIONAL: Communication with the Environmental Monitor has been established.
TRAP-TYPE    
  mtrapargsString  

mupsCommunicationLost 1.3.6.1.4.1.318.66
SEVERE: Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress.
TRAP-TYPE    
  mtrapargsString  

batteryIncrease 1.3.6.1.4.1.318.67
INFORMATIONAL: The number of batteries has increased.
TRAP-TYPE    
  mtrapargsString  

batteryDecrease 1.3.6.1.4.1.318.68
INFORMATIONAL: The number of batteries has decreased.
TRAP-TYPE    
  mtrapargsString  

powerModuleIncrease 1.3.6.1.4.1.318.69
INFORMATIONAL: The number of power modules has increased.
TRAP-TYPE    
  mtrapargsString  

powerModuleDecrease 1.3.6.1.4.1.318.70
INFORMATIONAL: The number of power modules has decreased.
TRAP-TYPE    
  mtrapargsString  

intelligenceModuleInserted 1.3.6.1.4.1.318.71
INFORMATIONAL: An intelligence module has been inserted.
TRAP-TYPE    
  mtrapargsString  

intelligenceModuleRemoved 1.3.6.1.4.1.318.72
INFORMATIONAL: An intelligence module has been removed.
TRAP-TYPE    
  mtrapargsString  

rintelligenceModuleInserted 1.3.6.1.4.1.318.73
INFORMATIONAL: A redundant intelligence module has been inserted.
TRAP-TYPE    
  mtrapargsString  

rintelligenceModuleRemoved 1.3.6.1.4.1.318.74
INFORMATIONAL: A redundant intelligence module has been removed.
TRAP-TYPE    
  mtrapargsString  

extBatteryFrameIncease 1.3.6.1.4.1.318.75
INFORMATIONAL: An external battery frame has been added.
TRAP-TYPE    
  mtrapargsString  

extBatteryFrameDecrease 1.3.6.1.4.1.318.76
INFORMATIONAL: An external battery frame has been removed.
TRAP-TYPE    
  mtrapargsString  

abnormalCondition 1.3.6.1.4.1.318.77
SEVERE: An abnormal condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

abnormalConditionCleared 1.3.6.1.4.1.318.78
INFORMATIONAL: An abnormal condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

deviceStatusChange 1.3.6.1.4.1.318.79
INFORMATIONAL: The status of the device being monitored has changed.
TRAP-TYPE    
  mtrapargsString  

noBatteries 1.3.6.1.4.1.318.80
WARNING: The UPS has no batteries attached.
TRAP-TYPE    
  mtrapargsString  

noBatteriesCleared 1.3.6.1.4.1.318.81
INFORMATIONAL: The UPS's batteries have been attached.
TRAP-TYPE    
  mtrapargsString  

userAdded 1.3.6.1.4.1.318.82
INFORMATIONAL: A new user has been added.
TRAP-TYPE    
  mtrapargsString  

userDeleted 1.3.6.1.4.1.318.83
INFORMATIONAL: A user has been deleted.
TRAP-TYPE    
  mtrapargsString  

userModified 1.3.6.1.4.1.318.84
INFORMATIONAL: A user has been modified.
TRAP-TYPE    
  mtrapargsString  

msvmCommunicationEstablished 1.3.6.1.4.1.318.85
INFORMATIONAL: Communications with the MasterSwitch VM has been established.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmCommunicationLost 1.3.6.1.4.1.318.86
SEVERE: Communications with the MasterSwitch VM has been lost.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmOverload 1.3.6.1.4.1.318.87
SEVERE: The MasterSwitch VM in an overload condition.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmOverloadCleared 1.3.6.1.4.1.318.88
INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmOutletOn 1.3.6.1.4.1.318.89
INFORMATIONAL: An outlet on the MasterSwitch VM has turned on.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  sPDUOutletControlVMOutletIndex  
  sPDUOutletControlVMOutletName  
  mtrapargsString  

msvmOutletOff 1.3.6.1.4.1.318.90
INFORMATIONAL: An outlet on the MasterSwitch VM has turned off.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  sPDUOutletControlVMOutletIndex  
  sPDUOutletControlVMOutletName  
  mtrapargsString  

msvmDeviceConfigChange 1.3.6.1.4.1.318.91
INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmOutletConfigChange 1.3.6.1.4.1.318.92
INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  sPDUOutletControlVMOutletIndex  
  sPDUOutletControlVMOutletName  
  mtrapargsString  

msvmLowLoad 1.3.6.1.4.1.318.93
INFORMATIONAL: The MasterSwitch VM has violated the low load threshold.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmLowLoadCleared 1.3.6.1.4.1.318.94
INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmNearOverload 1.3.6.1.4.1.318.95
SEVERE: The MasterSwitch VM is approaching an overload condition.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmNearOverloadCleared 1.3.6.1.4.1.318.96
INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsString  

msvmPowerSupplyStatusChange 1.3.6.1.4.1.318.97
WARNING: The power supply status of the MasterSwitch VM has changed.
TRAP-TYPE    
  sPDUMasterControlVMIndex  
  sPDUMasterControlVMName  
  mtrapargsInteger  
  mtrapargsString  

mspCommunicationEstablished 1.3.6.1.4.1.318.98
INFORMATIONAL: Communications with the MasterSwitch plus has been established.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  mtrapargsString  

mspCommunicationLost 1.3.6.1.4.1.318.99
SEVERE: Communications with the MasterSwitch plus has been lost.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  mtrapargsString  

mspOutletOn 1.3.6.1.4.1.318.100
INFORMATIONAL: An outlet on the MasterSwitch plus has turned on.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  sPDUOutletControlMSPOutletIndex  
  sPDUOutletControlMSPOutletName  
  mtrapargsString  

mspOutletOff 1.3.6.1.4.1.318.101
INFORMATIONAL: An outlet on the MasterSwitch plus has turned off.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  sPDUOutletControlMSPOutletIndex  
  sPDUOutletControlMSPOutletName  
  mtrapargsString  

mspDeviceConfigChange 1.3.6.1.4.1.318.102
INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  mtrapargsString  

mspOutletConfigChange 1.3.6.1.4.1.318.103
INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus.
TRAP-TYPE    
  sPDUMasterControlMSPIndex  
  sPDUMasterControlMSPName  
  sPDUOutletControlMSPOutletIndex  
  sPDUOutletControlMSPOutletName  
  mtrapargsString  

rsSourceSwitched 1.3.6.1.4.1.318.104
INFORMATIONAL: The Redundant Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source. The third variable is an integer representing the transfer cause: 0=No Transfers Recorded, 1=Due to user action or preferred switching, 3=Due to line notch or spike, 5=Due to low line voltage, 7=Transfer due to high line voltage, 9=Transfer due to frequency out of range. The fourth variable is a character string listing the transfer cause.
TRAP-TYPE    
  mtrapargsInteger02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

rsLostRedundancy 1.3.6.1.4.1.318.105
SEVERE: The Redundant Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

rsRedundancyRestored 1.3.6.1.4.1.318.106
INFORMATIONAL: Redundancy has been restored to the Redundant Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

rsConfigChange 1.3.6.1.4.1.318.107
INFORMATIONAL: A configuration change has been made on a Redundant Switch.
TRAP-TYPE    
  mtrapargsString  

rsCommunicationEstablished 1.3.6.1.4.1.318.108
INFORMATIONAL: Communications with the Redundant Switch has been established.
TRAP-TYPE    
  mtrapargsString  

rsCommunicationLost 1.3.6.1.4.1.318.109
SEVERE: Communications with the Redundant Switch has been lost.
TRAP-TYPE    
  mtrapargsString  

dcCommunicationEstablished 1.3.6.1.4.1.318.110
INFORMATIONAL: Communications with the DC power plant has been established.
TRAP-TYPE    
  mtrapargsString  

dcCommunicationLost 1.3.6.1.4.1.318.111
SEVERE: Communications with the DC power plant has been lost.
TRAP-TYPE    
  mtrapargsString  

dcPINChanged 1.3.6.1.4.1.318.112
INFORMATIONAL: The active PIN on the DC controller has been changed.
TRAP-TYPE    
  mtrapargsString  

dcMajorAlarm 1.3.6.1.4.1.318.113
SEVERE: A Major alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcMajorAlarmCleared 1.3.6.1.4.1.318.114
INFORMATIONAL: A Major alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcMinorAlarm 1.3.6.1.4.1.318.115
WARNING: A Minor alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcMinorAlarmCleared 1.3.6.1.4.1.318.116
INFORMATIONAL: A Minor alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcOutputRelayOn 1.3.6.1.4.1.318.117
WARNING: An output relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the output relay number that has gone on. The second variable is the 16-character name of the output relay.
TRAP-TYPE    
  dm3StatusOutRlyIndex  
  dm3StatusOutRlyName  
  mtrapargsString  

dcOutputRelayOff 1.3.6.1.4.1.318.118
INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the output relay number that has gone off. The second variable is the 16-character name of the output relay.
TRAP-TYPE    
  dm3StatusOutRlyIndex  
  dm3StatusOutRlyName  
  mtrapargsString  

dcInputRelayOn 1.3.6.1.4.1.318.119
WARNING: An input relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the input relay number that has gone on. The second variable is the 16-character name of the input relay.
TRAP-TYPE    
  dm3StatusInRlyIndex  
  dm3StatusInRlyName  
  mtrapargsString  

dcInputRelayOff 1.3.6.1.4.1.318.120
INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the input relay number that has gone off. The second variable is the 16-character name of the input relay.
TRAP-TYPE    
  dm3StatusInRlyIndex  
  dm3StatusInRlyName  
  mtrapargsString  

logicPowerSuppliesIncreased 1.3.6.1.4.1.318.121
INFORMATIONAL: The number of system power supplies has increased.
TRAP-TYPE    
  mtrapargsString  

logicPowerSuppliesDecreased 1.3.6.1.4.1.318.122
INFORMATIONAL: The number of system power supplies has decreased.
TRAP-TYPE    
  mtrapargsString  

externalSwitchGearClosed 1.3.6.1.4.1.318.123
INFORMATIONAL: External Switch Gear closed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString  

externalSwitchGearOpened 1.3.6.1.4.1.318.124
INFORMATIONAL: External Switch Gear opened.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString  

generalDeviceEvent 1.3.6.1.4.1.318.125
INFORMATIONAL: APC Device event.
TRAP-TYPE    
  mtrapargsString  

atsSourceSwitched 1.3.6.1.4.1.318.126
INFORMATIONAL: The Automatic Transfer Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

atsLostRedundancy 1.3.6.1.4.1.318.127
SEVERE: The Automatic Transfer Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

atsRedundancyRestored 1.3.6.1.4.1.318.128
INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsString  

atsConfigChange 1.3.6.1.4.1.318.129
INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch. The first variable is an integer representing the configuration setting which changed: 0=Transfer Voltage Range, 1=Sensitivity, 2=Preferred Source 3=Front Panel Lockout, 4=Current Limit, 5=Reset XA Processor, 6=Reset to defaults, 7=Product Name, 8=Nominal Voltage, 9=Nominal Line Frequency, 10=Narrow VRMS, 11=Medium VRMS, 12=Wide VRMS,13=Frequency Deviation, 14=ColdStart ATS, 15=Events Count Cleared, 16=Phase or Bank Threshold.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

atsCommunicationEstablished 1.3.6.1.4.1.318.130
INFORMATIONAL: Communications with the Automatic Transfer Switch has been established.
TRAP-TYPE    
  mtrapargsString  

atsCommunicationLost 1.3.6.1.4.1.318.131
SEVERE: Communications with the Automatic Transfer Switch has been lost.
TRAP-TYPE    
  mtrapargsString  

atsOverCurrent 1.3.6.1.4.1.318.132
SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap for phase or total in case banked units
TRAP-TYPE    
  mtrapargsString  

atsOverCurrentCleared 1.3.6.1.4.1.318.133
INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap for phase or total in case banked units
TRAP-TYPE    
  mtrapargsString  

atsPowerSupplyFailure 1.3.6.1.4.1.318.134
SEVERE: The Automatic Transfer Switch Power Supply has failed. The first variable is an integer representing the Power Supply which has failed: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

atsPowerSupplyFailureCleared 1.3.6.1.4.1.318.135
INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared. The first variable is an integer representing the Power Supply which has cleared: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

dcMainsFailAlarm 1.3.6.1.4.1.318.136
WARNING: A Mains Fail alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcMainsFailAlarmCleared 1.3.6.1.4.1.318.137
INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcFanFailAlarm 1.3.6.1.4.1.318.138
WARNING: A Fan Fail alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcFanFailAlarmCleared 1.3.6.1.4.1.318.139
INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierOvertempAlarm 1.3.6.1.4.1.318.140
WARNING: Rect. Overtemp alarm is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierOvertempAlarmCleared 1.3.6.1.4.1.318.141
INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcCurrentLimitAlarm 1.3.6.1.4.1.318.142
WARNING: A Current Limit alarm is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcCurrentLimitAlarmCleared 1.3.6.1.4.1.318.143
INFORMATIONAL: Current Limit alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierFailAlarm 1.3.6.1.4.1.318.144
WARNING: A Rect. Fail alarm is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierFailAlarmCleared 1.3.6.1.4.1.318.145
INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcMultRectFailAlarm 1.3.6.1.4.1.318.146
WARNING: Multiple Rect. Fail alarm is active in the powerplant.
TRAP-TYPE    
  mtrapargsString  

dcMultRectFailAlarmCleared 1.3.6.1.4.1.318.147
INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant.
TRAP-TYPE    
  mtrapargsString  

dcBatteryBreakerAlarm 1.3.6.1.4.1.318.148
WARNING: Batt. Breaker alarm is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcBatteryBreakerAlarmCleared 1.3.6.1.4.1.318.149
INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierOVPAlarm 1.3.6.1.4.1.318.150
WARNING: A Rect. OVP alarm is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcRectifierOVPAlarmCleared 1.3.6.1.4.1.318.151
INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcLVDImminentAlarm 1.3.6.1.4.1.318.152
WARNING: A LVD Imminent alarm is active in the powerplant.
TRAP-TYPE    
  mtrapargsString  

dcLVDImminentAlarmCleared 1.3.6.1.4.1.318.153
INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant.
TRAP-TYPE    
  mtrapargsString  

dcFuseCBAlarm 1.3.6.1.4.1.318.154
WARNING: A Fuse/CB alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcFuseCBAlarmCleared 1.3.6.1.4.1.318.155
INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcBatteryTestFail 1.3.6.1.4.1.318.156
WARNING: A Battery Test failed in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcTemperatureAlarm 1.3.6.1.4.1.318.157
WARNING: A Temperature is active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcTemperatureAlarmCleared 1.3.6.1.4.1.318.158
INFORMATIONAL: A Temperature alarm is no longer active in the power plant.
TRAP-TYPE    
  mtrapargsString  

dcHumidityAlarm 1.3.6.1.4.1.318.159
WARNING: A Humidity alarm is active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcHumidityAlarmCleared 1.3.6.1.4.1.318.160
INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant.
TRAP-TYPE    
  mtrapargsString  

dcBBCommunicationEstablished 1.3.6.1.4.1.318.161
INFORMATIONAL: Power plant bridging board communications established.
TRAP-TYPE    
  mtrapargsString  

dcBBCommunicationLost 1.3.6.1.4.1.318.162
SEVERE: Power plant bridging board communications lost.
TRAP-TYPE    
  mtrapargsString  

iemHighTempThresholdViolation 1.3.6.1.4.1.318.163
SEVERE: High temperature threshold violated on Integrated Environmental Monitor probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name.
TRAP-TYPE    
  iemStatusProbeCurrentTemp  
  iemStatusProbeTempUnits  
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemHighTempThresholdViolationCleared 1.3.6.1.4.1.318.164
INFORMATIONAL: High temperature threshold violated on Integrated Environmental Monitor probe has been cleared. The first variable is the probe number. The second variable is the probe name.
TRAP-TYPE    
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemLowTempThresholdViolation 1.3.6.1.4.1.318.165
SEVERE: Low temperature threshold violated on integrated probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name.
TRAP-TYPE    
  iemStatusProbeCurrentTemp  
  iemStatusProbeTempUnits  
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemLowTempThresholdViolationCleared 1.3.6.1.4.1.318.166
INFORMATIONAL: Low temperature threshold violated on integrated probe has been cleared. The first variable is the probe number. The second variable is the probe name.
TRAP-TYPE    
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemHighHumidThresholdViolation 1.3.6.1.4.1.318.167
SEVERE: High humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name.
TRAP-TYPE    
  iemStatusProbeCurrentHumid  
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemHighHumidThresholdViolationCleared 1.3.6.1.4.1.318.168
INFORMATIONAL: High humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name.
TRAP-TYPE    
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemLowHumidThresholdViolation 1.3.6.1.4.1.318.169
SEVERE: Low humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name.
TRAP-TYPE    
  iemStatusProbeCurrentHumid  
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemLowHumidThresholdViolationCleared 1.3.6.1.4.1.318.170
INFORMATIONAL: Low humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name.
TRAP-TYPE    
  iemStatusProbeNumber  
  iemStatusProbeName  
  mtrapargsString  

iemProbeDisconnected 1.3.6.1.4.1.318.171
WARNING: The temperature/humidity probe on the Integrated Environmental Monitor has been disconnected. This trap is generated when a probe that has been in communication with the Environmental Monitor has been disconnected or can no longer communicate.
TRAP-TYPE    
  mtrapargsString  

iemProbeConnected 1.3.6.1.4.1.318.172
INFORMATIONAL: The temperature/humidity probe on the Integrated Environmental Monitor has been connected. This trap is generated when the Environmental Monitor establishes communication with a probe that had previously not been connected.
TRAP-TYPE    
  mtrapargsString  

iemContactFault 1.3.6.1.4.1.318.173
SEVERE: There is a contact fault on the Integrated Environmental Monitor. The first argument is the number of the contact. The second argument is the name of the contact.
TRAP-TYPE    
  iemStatusContactNumber  
  iemStatusContactName  
  mtrapargsString  

iemContactFaultCleared 1.3.6.1.4.1.318.174
INFORMATIONAL: The contact fault on the Integrated Environmental Monitor has been cleared. The first argument is the number of the contact. The second argument is the name of the contact.
TRAP-TYPE    
  iemStatusContactNumber  
  iemStatusContactName  
  mtrapargsString  

iemRelayFault 1.3.6.1.4.1.318.175
SEVERE: The output relay on the Integrated Environmental Monitor has switched to the fault state. The first argument is the number of the output relay. The second argument is the name of the output relay. The third argument is the event that caused the fault.
TRAP-TYPE    
  iemStatusRelayNumber  
  iemStatusRelayName  
  mtrapargsString02  
  mtrapargsString  

iemRelayFaultCleared 1.3.6.1.4.1.318.176
INFORMATIONAL: The fault condition on the output relay on the Integrated Environmental Monitor has cleared. The first argument is the number of the output relay. The second argument is the name of the output relay.
TRAP-TYPE    
  iemStatusRelayNumber  
  iemStatusRelayName  
  mtrapargsString  

bmBatManCommEstab 1.3.6.1.4.1.318.177
INFORMATIONAL: Serial Communications Established with Battery Manager.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManCommLost 1.3.6.1.4.1.318.178
SEVERE: Serial Communications Lost with Battery Manager.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManKneeAlarm 1.3.6.1.4.1.318.179
SEVERE: Battery Voltage Knee Threshold Alarm Detected.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManKneeAlarmCleared 1.3.6.1.4.1.318.180
INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManChargerAlarm 1.3.6.1.4.1.318.181
WARNING: Charger Alarm Detected.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManChargerAlarmCleared 1.3.6.1.4.1.318.182
INFORMATIONAL: Charger Alarm Cleared.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManBatteryAlarm 1.3.6.1.4.1.318.183
WARNING: Battery Alarm Detected.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManBatteryAlarmCleared 1.3.6.1.4.1.318.184
INFORMATIONAL: Battery Alarm Cleared.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManEnvironmentAlarm 1.3.6.1.4.1.318.185
WARNING: Environment Alarm Detected.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManEnvironmentAlarmCleared 1.3.6.1.4.1.318.186
INFORMATIONAL: Environment Alarm Cleared.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManMaintenanceAlarm 1.3.6.1.4.1.318.187
INFORMATIONAL: Maintenance Alarm Detected.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

bmBatManMaintenanceAlarmCleared 1.3.6.1.4.1.318.188
INFORMATIONAL: Maintenance Alarm Cleared.
TRAP-TYPE    
  mtrapargsInteger  
  mtrapargsString  

pduCommunicationEstablished 1.3.6.1.4.1.318.189
INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduCommunicationLost 1.3.6.1.4.1.318.190
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduUtilityLineUndervoltage 1.3.6.1.4.1.318.191
SEVERE: Utility Line Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduUtilityLineUndervoltageCleared 1.3.6.1.4.1.318.192
INFORMATIONAL: Utility Line Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduUtilityLineOvervoltage 1.3.6.1.4.1.318.193
SEVERE: Utility Line Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduUtilityLineOvervoltageCleared 1.3.6.1.4.1.318.194
INFORMATIONAL: Utility Line Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduGroundOvercurrent 1.3.6.1.4.1.318.195
SEVERE: Ground Overcurrent. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduGroundOvercurrentCleared 1.3.6.1.4.1.318.196
INFORMATIONAL: Ground Overcurrent Cleared. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduCircuitPanelInputUndervoltage 1.3.6.1.4.1.318.197
SEVERE: Circuit Panel Input Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputUndervoltageCleared 1.3.6.1.4.1.318.198
INFORMATIONAL: Circuit Panel Input Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputOvervoltage 1.3.6.1.4.1.318.199
SEVERE: Circuit Panel Input Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputOvervoltageCleared 1.3.6.1.4.1.318.200
INFORMATIONAL: Circuit Panel Input Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputUndercurrent 1.3.6.1.4.1.318.201
SEVERE: Circuit Panel Input Undercurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputUndercurrentCleared 1.3.6.1.4.1.318.202
INFORMATIONAL: Circuit Panel Input Undercurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputOvercurrent 1.3.6.1.4.1.318.203
SEVERE: Circuit Panel Input Overcurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelInputOvercurrentCleared 1.3.6.1.4.1.318.204
INFORMATIONAL: Circuit Panel Input Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduCircuitPanelFrequencyOutOfRange 1.3.6.1.4.1.318.205
SEVERE: Circuit Panel Input Frequency Out Of Range. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduCircuitPanelFrequencyOutofRangeCleared 1.3.6.1.4.1.318.206
INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduCircuitPanelNeutralOvercurrent 1.3.6.1.4.1.318.207
SEVERE: Circuit Panel Input Neutral Overcurrent. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduCircuitPanelNeutralOvercurrentCleared 1.3.6.1.4.1.318.208
INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduSystemOff 1.3.6.1.4.1.318.209
SEVERE: PDU System Off. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduOnBatteryMode 1.3.6.1.4.1.318.210
SEVERE: PDU is in On Battery Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduMaintenanceBypassMode 1.3.6.1.4.1.318.211
INFORMATIONAL: PDU is in Maintenance Bypass Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduAtypicalBypassMode 1.3.6.1.4.1.318.212
WARNING: PDU is in Atypical Bypass Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduNoPanelFeedMode 1.3.6.1.4.1.318.213
SEVERE: PDU is in No Panel Feed Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduUpsOperationMode 1.3.6.1.4.1.318.214
INFORMATIONAL: PDU is in Ups Operation Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduForcedBypassMode 1.3.6.1.4.1.318.215
WARNING: PDU is in Forced Bypass Mode. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduInputTransformerOverTemperature 1.3.6.1.4.1.318.216
SEVERE: Input Transformer Over Temperature. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduInputTransformerOverTemperatureCleared 1.3.6.1.4.1.318.217
INFORMATIONAL: Input Transformer Over Temperature Cleared. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

pduUPSInputVoltageLost 1.3.6.1.4.1.318.218
SEVERE: UPS Input Voltage phase-N Lost. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduUPSInputVoltageRestored 1.3.6.1.4.1.318.219
INFORMATIONAL: UPS Input Voltage phase-N Restored. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduContactFault 1.3.6.1.4.1.318.220
SEVERE: A contact closure in the PDU is in an abnormal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

pduContactFaultCleared 1.3.6.1.4.1.318.221
INFORMATIONAL: A contact closure in the PDU is in a normal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

rPDUBankPhaseLowLoad 1.3.6.1.4.1.318.222
WARNING: A bank or phase on the Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUBankPhaseLowLoadCleared 1.3.6.1.4.1.318.223
INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUBankPhaseNearOverload 1.3.6.1.4.1.318.224
WARNING: A bank or phase of the Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUBankPhaseNearOverloadCleared 1.3.6.1.4.1.318.225
INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUBankPhaseOverload 1.3.6.1.4.1.318.226
SEVERE: A bank or phase of the Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUBankPhaseOverloadCleared 1.3.6.1.4.1.318.227
INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusBankNumber  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

aruDeviceConfigChange 1.3.6.1.4.1.318.228
INFORMATIONAL: Remote ARU Device Configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

rmPDUCommunicationLost 1.3.6.1.4.1.318.229
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  mtrapargsString03  
  mtrapargsString02  
  mtrapargsString  

emsCommunicationEstablished 1.3.6.1.4.1.318.230
INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsCommunicationLost 1.3.6.1.4.1.318.231
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsProbeConnected 1.3.6.1.4.1.318.232
INFORMATIONAL: A probe has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

emsProbeDisconnected 1.3.6.1.4.1.318.233
SEVERE: A probe has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

emsSensorConnected 1.3.6.1.4.1.318.234
INFORMATIONAL: A sensor has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsSensorStatusSensorIndex  
  emsSensorStatusSensorName  
  mtrapargsString  

emsSensorDisconnected 1.3.6.1.4.1.318.235
SEVERE: A sensor has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsSensorStatusSensorIndex  
  emsSensorStatusSensorName  
  mtrapargsString  

emsSensorFault 1.3.6.1.4.1.318.236
SEVERE: A EMS sensor is in the fault condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsSensorStatusSensorIndex  
  emsSensorStatusSensorName  
  mtrapargsString  

emsSensorFaultCleared 1.3.6.1.4.1.318.237
INFORMATIONAL: A EMS sensor fault condition has cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsSensorStatusSensorIndex  
  emsSensorStatusSensorName  
  mtrapargsString  

emsBeaconConnected 1.3.6.1.4.1.318.238
INFORMATIONAL: A beacon has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsBeaconDisconnected 1.3.6.1.4.1.318.239
SEVERE: A beacon has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsBeaconOn 1.3.6.1.4.1.318.240
INFORMATIONAL: A EMS beacon has gone on. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsBeaconOff 1.3.6.1.4.1.318.241
INFORMATIONAL: A EMS beacon has gone off. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsMajorAlarm 1.3.6.1.4.1.318.242
SEVERE: A Major Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsMajorAlarmCleared 1.3.6.1.4.1.318.243
INFORMATIONAL: A Major Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsMinorAlarm 1.3.6.1.4.1.318.244
SEVERE: A Minor Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsMinorAlarmCleared 1.3.6.1.4.1.318.245
INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsOutletStateAbnormal 1.3.6.1.4.1.318.246
WARNING: An outlet on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsOutletStatusOutletIndex  
  emsOutletStatusOutletName  
  emsOutletStatusOutletState  
  emsOutletStatusOutletNormalState  
  mtrapargsString  

emsOutletStateNormal 1.3.6.1.4.1.318.247
INFORMATIONAL: An outlet on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsOutletStatusOutletIndex  
  emsOutletStatusOutletName  
  emsOutletStatusOutletState  
  emsOutletStatusOutletNormalState  
  mtrapargsString  

emsInputContactStateAbnormal 1.3.6.1.4.1.318.248
WARNING: An input contact on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsInputContactStatusInputContactIndex  
  emsInputContactStatusInputContactName  
  emsInputContactStatusInputContactState  
  emsInputContactStatusInputContactNormalState  
  mtrapargsString  

emsInputContactStateNormal 1.3.6.1.4.1.318.249
INFORMATIONAL: An input contact on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsInputContactStatusInputContactIndex  
  emsInputContactStatusInputContactName  
  emsInputContactStatusInputContactState  
  emsInputContactStatusInputContactNormalState  
  mtrapargsString  

emsOutputRelayStateAbnormal 1.3.6.1.4.1.318.250
WARNING: An output relay on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsOutputRelayStatusOutputRelayIndex  
  emsOutputRelayStatusOutputRelayName  
  emsOutputRelayStatusOutputRelayState  
  emsOutputRelayStatusOutputRelayNormalState  
  mtrapargsString  

emsOutputRelayStateNormal 1.3.6.1.4.1.318.251
INFORMATIONAL: An output relay on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsOutputRelayStatusOutputRelayIndex  
  emsOutputRelayStatusOutputRelayName  
  emsOutputRelayStatusOutputRelayState  
  emsOutputRelayStatusOutputRelayNormalState  
  mtrapargsString  

emsDeviceConfigChange 1.3.6.1.4.1.318.252
INFORMATIONAL: A device configuration change has been made on the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

envHighTempThresholdViolation 1.3.6.1.4.1.318.253
SEVERE: High temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envHighTempThresholdViolationCleared 1.3.6.1.4.1.318.254
INFORMATIONAL: High temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLowTempThresholdViolation 1.3.6.1.4.1.318.255
SEVERE: Low temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLowTempThresholdViolationCleared 1.3.6.1.4.1.318.256
INFORMATIONAL: Low temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envHighHumidityThresholdViolation 1.3.6.1.4.1.318.257
SEVERE: High humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envHighHumidityThresholdViolationCleared 1.3.6.1.4.1.318.258
INFORMATIONAL: High humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLowHumidityThresholdViolation 1.3.6.1.4.1.318.259
SEVERE: Low humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLowHumidityThresholdViolationCleared 1.3.6.1.4.1.318.260
INFORMATIONAL: Low humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

rPDUCommunicationEstablished 1.3.6.1.4.1.318.266
INFORMATIONAL: Communication with a Rack PDU has been established. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUCommunicationLost 1.3.6.1.4.1.318.267
SEVERE: Communication with a Rack PDU has been lost. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUOutletOn 1.3.6.1.4.1.318.268
INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletControlIndex  
  rPDUOutletControlOutletName  
  mtrapargsString  

rPDUOutletOff 1.3.6.1.4.1.318.269
INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletControlIndex  
  rPDUOutletControlOutletName  
  mtrapargsString  

rPDUDeviceConfigChange 1.3.6.1.4.1.318.270
INFORMATIONAL: A device configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUOutletConfigChange 1.3.6.1.4.1.318.271
INFORMATIONAL: An outlet configuration change has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletControlIndex  
  rPDUOutletControlOutletName  
  mtrapargsString  

rPDULowLoad 1.3.6.1.4.1.318.272
WARNING: A Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDULowLoadCleared 1.3.6.1.4.1.318.273
INFORMATIONAL: The low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUNearOverload 1.3.6.1.4.1.318.274
WARNING: A Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUNearOverloadCleared 1.3.6.1.4.1.318.275
INFORMATIONAL: The near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUOverload 1.3.6.1.4.1.318.276
SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUOverloadCleared 1.3.6.1.4.1.318.277
INFORMATIONAL: The overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadStatusPhaseNumber  
  mtrapargsString  

rPDUPowerSupply1Fail 1.3.6.1.4.1.318.278
SEVERE: Power Supply 1 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUPowerSupply1Ok 1.3.6.1.4.1.318.279
INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUPowerSupply2Fail 1.3.6.1.4.1.318.280
SEVERE: Power Supply 2 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUPowerSupply2Ok 1.3.6.1.4.1.318.281
INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  mtrapargsString  

rPDUPhaseConfigChange 1.3.6.1.4.1.318.282
INFORMATIONAL: A phase configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the phase index number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDULoadPhaseConfigIndex  
  mtrapargsString  

rPDUCancelPendingCommand 1.3.6.1.4.1.318.283
INFORMATIONAL: A cancel pending command has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number (0 indicates all outlets). The fourth argument is the outlet name (or device name if all outlets).
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletControlIndex  
  rPDUOutletControlOutletName  
  mtrapargsString  

aruAlinkCommunicationEstablished 1.3.6.1.4.1.318.284
INFORMATIONAL: Remote ARU Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruAlinkCommunicationLost 1.3.6.1.4.1.318.285
SEVERE: Remote ARU Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruFanFail 1.3.6.1.4.1.318.286
SEVERE: Remote ARU Fan Fail. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruFanFailCleared 1.3.6.1.4.1.318.287
INFORMATIONAL: Remote ARU Fan Fail Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruSmokeAlarm 1.3.6.1.4.1.318.288
SEVERE: Remote ARU Smoke Alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruSmokeAlarmCleared 1.3.6.1.4.1.318.289
INFORMATIONAL: Remote ARU Smoke Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruHighTemperatureAlarm 1.3.6.1.4.1.318.290
WARNING: ARU Exhaust temperature has exceeded the override threshold and the ARU has increased fan speed to maintain a safe environment in the rack. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruHighTemperatureAlarmCleared 1.3.6.1.4.1.318.291
INFORMATIONAL: ARU temperature override state has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruExhaustTemperatureAlarm 1.3.6.1.4.1.318.292
SEVERE: ARU Extreme Exhaust Temperature Alarm. The ARU is unable to control the temperature within the rack The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruExhaustTemperatureAlarmCleared 1.3.6.1.4.1.318.293
INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

envAlinkCommunicationEstablished 1.3.6.1.4.1.318.294
INFORMATIONAL: Remote Probe Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envAlinkCommunicationLost 1.3.6.1.4.1.318.295
SEVERE: Remote Probe Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

emsAlinkPowerOverload 1.3.6.1.4.1.318.296
SEVERE: Alink Power Overload. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsAlinkPowerOverloadCleared 1.3.6.1.4.1.318.297
INFORMATIONAL: Alink Power Overload Cleared. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

upsOutletGroupTurnedOn 1.3.6.1.4.1.318.298
INFORMATIONAL: The specified Outlet Group turned on.
TRAP-TYPE    
  upsOutletGroupControlIndex  
  mtrapargsString  

upsOutletGroupTurnedOff 1.3.6.1.4.1.318.299
WARNING: The specified Outlet Group turned off.
TRAP-TYPE    
  upsOutletGroupControlIndex  
  mtrapargsString  

smwCriticalCondition 1.3.6.1.4.1.318.300
SEVERE: A Symmetra MW UPS critical condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

smwCriticalConditionCleared 1.3.6.1.4.1.318.301
INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

smwWarningCondition 1.3.6.1.4.1.318.302
WARNING: A Symmetra MW UPS warning condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

smwWarningConditionCleared 1.3.6.1.4.1.318.303
WARNING: A Symmetra MW UPS warning condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

smwInformationalCondition 1.3.6.1.4.1.318.304
INFORMATIONAL: A Symmetra MW UPS informational condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

smwInformationalConditionCleared 1.3.6.1.4.1.318.305
INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsGauge  
  mtrapargsString  

airCriticalCondition 1.3.6.1.4.1.318.306
SEVERE: An Air critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

airCriticalConditionCleared 1.3.6.1.4.1.318.307
INFORMATIONAL: An Air critical condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

airWarningCondition 1.3.6.1.4.1.318.308
WARNING: An Air warning condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

airWarningConditionCleared 1.3.6.1.4.1.318.309
WARNING: An Air warning condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

airInformationalCondition 1.3.6.1.4.1.318.310
INFORMATIONAL: An Air informational condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

airInformationalConditionCleared 1.3.6.1.4.1.318.311
INFORMATIONAL: An Air informational condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

xPDUInputVoltageLowAlarm 1.3.6.1.4.1.318.312
SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUInputVoltageLowAlarmCleared 1.3.6.1.4.1.318.313
INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUInputVoltageHighAlarm 1.3.6.1.4.1.318.314
SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUInputVoltageHighAlarmCleared 1.3.6.1.4.1.318.315
INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUBypassVoltageLowAlarm 1.3.6.1.4.1.318.316
SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBypassVoltageLowAlarmCleared 1.3.6.1.4.1.318.317
INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUBypassVoltageHighAlarm 1.3.6.1.4.1.318.318
SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBypassVoltageHighAlarmCleared 1.3.6.1.4.1.318.319
INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputVoltageLowAlarm 1.3.6.1.4.1.318.320
SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUOutputVoltageLowAlarmCleared 1.3.6.1.4.1.318.321
INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputVoltageHighAlarm 1.3.6.1.4.1.318.322
SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUOutputVoltageHighAlarmCleared 1.3.6.1.4.1.318.323
INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputCurrentLowAlarm 1.3.6.1.4.1.318.324
SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUOutputCurrentLowAlarmCleared 1.3.6.1.4.1.318.325
INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputCurrentHighAlarm 1.3.6.1.4.1.318.326
SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUOutputCurrentHighAlarmCleared 1.3.6.1.4.1.318.327
INFORMATIONAL: The three-phase output current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputFrequencyAlarm 1.3.6.1.4.1.318.328
SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUOutputFrequencyAlarmCleared 1.3.6.1.4.1.318.329
INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUSystemGroundCurrentAlarm 1.3.6.1.4.1.318.330
SEVERE: The earth ground current of the device is over the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUSystemGroundCurrentAlarmCleared 1.3.6.1.4.1.318.331
INFORMATIONAL: The earth ground current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUInputContactStateAbnormal 1.3.6.1.4.1.318.332
SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUInputContactStateNormal 1.3.6.1.4.1.318.333
INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUOutputNeutralCurrentHighAlarm 1.3.6.1.4.1.318.334
WARNING: The three-phase neutral current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUOutputNeutralCurrentHighAlarmCleared 1.3.6.1.4.1.318.335
INFORMATIONAL: The output neutral current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUCoolingFanAlarm 1.3.6.1.4.1.318.336
SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUCoolingFanAlarmCleared 1.3.6.1.4.1.318.337
INFORMATIONAL: The device's cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUTransformerTempAlarm 1.3.6.1.4.1.318.338
SEVERE: The device's isolation transformer is over temperature. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUTransformerTempAlarmCleared 1.3.6.1.4.1.318.339
INFORMATIONAL: The device's isolation transformer is no longer over temperature. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUBranchCurrentLowAlarm 1.3.6.1.4.1.318.340
WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBranchCurrentLowAlarmCleared 1.3.6.1.4.1.318.341
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUBranchCurrentHighAlarm 1.3.6.1.4.1.318.342
WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBranchCurrentHighAlarmCleared 1.3.6.1.4.1.318.343
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUInternalCommError 1.3.6.1.4.1.318.344
SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

emsHardwareStateAbnormal 1.3.6.1.4.1.318.345
SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to the EMS ports or Alink Current limit detection.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

emsHardwareStateNormal 1.3.6.1.4.1.318.346
INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  mtrapargsString  

ceSevereCondition 1.3.6.1.4.1.318.347
SEVERE: A Custom Event severe condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

ceSevereConditionCleared 1.3.6.1.4.1.318.348
INFORMATIONAL: A Custom Event severe condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

ceWarningCondition 1.3.6.1.4.1.318.349
WARNING: A Custom Event warning condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

ceWarningConditionCleared 1.3.6.1.4.1.318.350
INFORMATIONAL: A Custom Event warning condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

ceInformationalCondition 1.3.6.1.4.1.318.351
INFORMATIONAL: A Custom Event informational condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

ceInformationalConditionCleared 1.3.6.1.4.1.318.352
INFORMATIONAL: A Custom Event informational condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsInternalOverTemperature 1.3.6.1.4.1.318.353
WARNING: The internal over temperature condition exists.
TRAP-TYPE    
  mtrapargsString  

upsInternalOverTemperatureCleared 1.3.6.1.4.1.318.354
INFORMATIONAL: The internal over temperature condition cleared.
TRAP-TYPE    
  mtrapargsString  

upsMpuReset 1.3.6.1.4.1.318.355
INFORMATIONAL: The MPU has been reset.
TRAP-TYPE    
  mtrapargsString  

upsOutputSwitchClosed 1.3.6.1.4.1.318.356
INFORMATIONAL: The Output Switch is closed.
TRAP-TYPE    
  mtrapargsString  

upsOutputSwitchOpened 1.3.6.1.4.1.318.357
INFORMATIONAL: The Output Switch is open.
TRAP-TYPE    
  mtrapargsString  

upsCalibrationStackChanged 1.3.6.1.4.1.318.358
INFORMATIONAL: A calibration value in the stack was changed.
TRAP-TYPE    
  mtrapargsString  

envMaxTempThresholdViolation 1.3.6.1.4.1.318.359
SEVERE: Max temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMaxTempThresholdViolationCleared 1.3.6.1.4.1.318.360
INFORMATIONAL: Max temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMinTempThresholdViolation 1.3.6.1.4.1.318.361
SEVERE: Min temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMinTempThresholdViolationCleared 1.3.6.1.4.1.318.362
INFORMATIONAL: Min temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMaxHumidityThresholdViolation 1.3.6.1.4.1.318.363
SEVERE: Max humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMaxHumidityThresholdViolationCleared 1.3.6.1.4.1.318.364
INFORMATIONAL: Max humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMinHumidityThresholdViolation 1.3.6.1.4.1.318.365
SEVERE: Min humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envMinHumidityThresholdViolationCleared 1.3.6.1.4.1.318.366
INFORMATIONAL: Min humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeHumidity  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envSTIncTempRateViolation 1.3.6.1.4.1.318.367
SEVERE: Short-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envSTIncTempRateViolationCleared 1.3.6.1.4.1.318.368
INFORMATIONAL: Short-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envSTDecTempRateViolation 1.3.6.1.4.1.318.369
SEVERE: Short-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envSTDecTempRateViolationCleared 1.3.6.1.4.1.318.370
INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLTIncTempRateViolation 1.3.6.1.4.1.318.371
SEVERE: Long-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLTIncTempRateViolationCleared 1.3.6.1.4.1.318.372
INFORMATIONAL: Long-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLTDecTempRateViolation 1.3.6.1.4.1.318.373
SEVERE: Long-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

envLTDecTempRateViolationCleared 1.3.6.1.4.1.318.374
INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  emsProbeStatusProbeTemperature  
  emsStatusSysTempUnits  
  emsProbeStatusProbeIndex  
  emsProbeStatusProbeName  
  mtrapargsString  

bmsCriticalCondition 1.3.6.1.4.1.318.375
SEVERE: A Battery Management System critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

bmsCriticalConditionCleared 1.3.6.1.4.1.318.376
INFORMATIONAL: A Battery Management System critical condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

bmsWarningCondition 1.3.6.1.4.1.318.377
WARNING: A Battery Management System warning condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

bmsWarningConditionCleared 1.3.6.1.4.1.318.378
WARNING: A Battery Management System warning condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

bmsInformationalCondition 1.3.6.1.4.1.318.379
INFORMATIONAL: A Battery Management System informational condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

bmsInformationalConditionCleared 1.3.6.1.4.1.318.380
INFORMATIONAL: A Battery Management System informational condition was cleared. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

xATSOutputVoltageLowAlarm 1.3.6.1.4.1.318.381
SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSOutputVoltageLowAlarmCleared 1.3.6.1.4.1.318.382
INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSOutputVoltageHighAlarm 1.3.6.1.4.1.318.383
SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSOutputVoltageHighAlarmCleared 1.3.6.1.4.1.318.384
INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSOutputCurrentLowAlarm 1.3.6.1.4.1.318.385
SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSOutputCurrentLowAlarmCleared 1.3.6.1.4.1.318.386
INFORMATIONAL: The three-phase load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSOutputCurrentHighAlarm 1.3.6.1.4.1.318.387
SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSOutputCurrentHighAlarmCleared 1.3.6.1.4.1.318.388
INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSOutputFrequencyAlarm 1.3.6.1.4.1.318.389
SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz. The fourth argument is the frequency deviation threshold in tenths of Hertz, from which the alarm was generated.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSOutputFrequencyAlarmCleared 1.3.6.1.4.1.318.390
INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSInternalCommError 1.3.6.1.4.1.318.391
SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSInternalCommErrorCleared 1.3.6.1.4.1.318.392
INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDataCommMismatchError 1.3.6.1.4.1.318.393
SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDataCommMismatchErrorCleared 1.3.6.1.4.1.318.394
INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGenCommLost 1.3.6.1.4.1.318.395
WARNING: The XATS cannot communicate with the generator. This will make unavailable all the xATSGenerator OIDs. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGenCommEstablished 1.3.6.1.4.1.318.396
INFORMATIONAL: The XATS has established communication with the generator. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSNeutralPosition 1.3.6.1.4.1.318.397
WARNING: XATS has transferred to neutral position. In this position neither Source 1 nor Source 2 is selected, and the XATS will have no output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSSwitchTransferEvent 1.3.6.1.4.1.318.398
INFORMATIONAL: XATS has transferred from one source to the other. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating. (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual). The fourth argument is the input source selected (1=Source 1, 2=Source 2). The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown)
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSInternalATSFault 1.3.6.1.4.1.318.399
SEVERE: An internal XATS fault has been detected. The XATS may have forced itself to not-in-auto mode (abnormal condition), as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSInternalATSFaultCleared 1.3.6.1.4.1.318.400
INFORMATIONAL: The detected internal XATS fault has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSEngineStartAsserted 1.3.6.1.4.1.318.401
INFORMATIONAL: The XATS has asserted the Engine Start contact. This should result in the generator producing output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the reason that the start signal was asserted 1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance, 5=S1 Freq Range, 6=S1 Bad Rotation.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSEngineStopAsserted 1.3.6.1.4.1.318.402
INFORMATIONAL: The XATS has de-asserted the Engine Start contact. This should result in the generator shutting down, and producing no output voltage. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSStartFailure 1.3.6.1.4.1.318.403
SEVERE: The generator failed to start. After assertion of the Engine Start signal, the quality of Source 2 was not seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the line quality at S2 1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance, 4=S2 Freq Range, 5=S2 Bad Rotation.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSStopFailure 1.3.6.1.4.1.318.404
WARNING: The generator failed to stop. After de-assertion of the Engine Start signal, the quality of Source 2 continued to be seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSNotInAutomaticMode 1.3.6.1.4.1.318.405
SEVERE: Automatic Transfer Switch is not in automatic mode. The first argument is the host device serial number. The second argument is the host device name. The xATSSwitchStatusAutoSwitchStatus OID and the xATSSwitchStatusAutoSwitchOperationalMode OID can provide more information about the state of the XATS.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSNotInAutomaticModeCleared 1.3.6.1.4.1.318.406
INFORMATIONAL: Automatic Transfer Switch is in automatic mode. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSEpoTripped 1.3.6.1.4.1.318.407
SEVERE: The device's Emergency Power Off (EPO) circuit is tripped. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSEpoReset 1.3.6.1.4.1.318.408
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been reset to the armed position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSEpoTestMode 1.3.6.1.4.1.318.409
WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSEpoArmed 1.3.6.1.4.1.318.410
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSTestInitiated 1.3.6.1.4.1.318.411
INFORMATIONAL: A scheduled test has been initiated. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSTestCanceled 1.3.6.1.4.1.318.412
INFORMATIONAL: The scheduled test has been canceled The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSTestFailed 1.3.6.1.4.1.318.413
SEVERE: The initiated test has failed. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSTestPassed 1.3.6.1.4.1.318.414
INFORMATIONAL: The initiated test has passed switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSInputContactStateAbnormal 1.3.6.1.4.1.318.415
SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSInputContactStateNormal 1.3.6.1.4.1.318.416
INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString02  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xATSRemoteStartContactMismatch 1.3.6.1.4.1.318.417
SEVERE: The state of the generator's Remote Start input and the ATS's Engine Start output do not match. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSRemoteStartContactMismatchCleared 1.3.6.1.4.1.318.418
INFORMATIONAL: Mismatch in the state of the generator's Remote Start input and the ATS's Engine Start output as been resolved. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDoorOpenAlarm 1.3.6.1.4.1.318.419
WARNING: The XATS exterior panel door is open. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDoorOpenAlarmCleared 1.3.6.1.4.1.318.420
INFORMATIONAL: The external door to the device is closed. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDCBackupAlarm 1.3.6.1.4.1.318.421
WARNING: The XATS's DC backup has been lost. The XATS will lose power on Source 1 failure, causing the Engine Start signal to be asserted. The XATS will then restart from Source 2. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSDCBackupAlarmCleared 1.3.6.1.4.1.318.422
INFORMATIONAL: DC backup alarm has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorLowCoolantLevelAlarm 1.3.6.1.4.1.318.423
SEVERE: Low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowCoolantLevelAlarmCleared 1.3.6.1.4.1.318.424
INFORMATIONAL: The detected low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowCoolantLevelAlarm 1.3.6.1.4.1.318.425
SEVERE: Very low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowCoolantLevelAlarmCleared 1.3.6.1.4.1.318.426
INFORMATIONAL: The detected Very low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorHighCoolantTempAlarm 1.3.6.1.4.1.318.427
SEVERE: High coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorHighCoolantTempAlarmCleared 1.3.6.1.4.1.318.428
INFORMATIONAL: The detected high coolant temperature has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryHighCoolantTempAlarm 1.3.6.1.4.1.318.429
SEVERE: Very high coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryHighCoolantTempAlarmCleared 1.3.6.1.4.1.318.430
INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowCoolantTempAlarm 1.3.6.1.4.1.318.431
WARNING: Low coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowCoolantTempAlarmCleared 1.3.6.1.4.1.318.432
INFORMATIONAL: The low coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowOilLevelAlarm 1.3.6.1.4.1.318.433
SEVERE: Low oil level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowOilLevelAlarmCleared 1.3.6.1.4.1.318.434
INFORMATIONAL: Low oil level alarm has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowBatteryVoltDuringCrankAlarm 1.3.6.1.4.1.318.435
SEVERE: The generator's battery voltage has been detected as low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared 1.3.6.1.4.1.318.436
INFORMATIONAL: The generator's low battery voltage while cranking condition has been cleared. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm 1.3.6.1.4.1.318.437
SEVERE: The generator's battery voltage has been detected as very low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared 1.3.6.1.4.1.318.438
INFORMATIONAL: The generator's high battery voltage while cranking condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorEStop 1.3.6.1.4.1.318.439
SEVERE: The generator's emergency stop input has been activated. After the emergency stop signal has been removed, the E-Stop condition must be cleared before the generator can be started again. E-Stop conditions can only be cleared via the generator front panel. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSGeneratorEStopCleared 1.3.6.1.4.1.318.440
INFORMATIONAL: The generator's emergency stop condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xATSGeneratorHighBatteryVolt 1.3.6.1.4.1.318.441
WARNING: The generator's battery voltage has been detected as high. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorHighBatteryVoltCleared 1.3.6.1.4.1.318.442
INFORMATIONAL: The detected high battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowBatteryVolt 1.3.6.1.4.1.318.443
SEVERE: The generator's battery voltage has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowBatteryVoltCleared 1.3.6.1.4.1.318.444
INFORMATIONAL: The detected low battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorControlSwitchNotAuto 1.3.6.1.4.1.318.445
SEVERE: The control switch on the generator is not in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorControlSwitchNotAutoCleared 1.3.6.1.4.1.318.446
INFORMATIONAL: The control switch on the generator is in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowOilPressure 1.3.6.1.4.1.318.447
SEVERE: The generator's oil pressure has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowOilPressureCleared 1.3.6.1.4.1.318.448
INFORMATIONAL: The detected low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowOilPressure 1.3.6.1.4.1.318.449
SEVERE: The generator's oil pressure has been detected as very low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowOilPressureCleared 1.3.6.1.4.1.318.450
INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOverload 1.3.6.1.4.1.318.451
SEVERE: The generator is overloaded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOverloadCleared 1.3.6.1.4.1.318.452
INFORMATIONAL: The generator is running within loading limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowACVEvent 1.3.6.1.4.1.318.453
SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowACVEventCleared 1.3.6.1.4.1.318.454
INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorHighACVEvent 1.3.6.1.4.1.318.455
SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorHighACVEventCleared 1.3.6.1.4.1.318.456
INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOverspeed 1.3.6.1.4.1.318.457
SEVERE: The generator is running over the acceptable RPM. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOverspeedCleared 1.3.6.1.4.1.318.458
INFORMATIONAL: The generator overspeed shutdown has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorEngineCold 1.3.6.1.4.1.318.459
SEVERE: The generator engine is cold, may not start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorEngineColdCleared 1.3.6.1.4.1.318.460
INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOutputBreakerOpen 1.3.6.1.4.1.318.461
SEVERE: The generators output breaker has been detected as open. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorOutputBreakerOpenCleared 1.3.6.1.4.1.318.462
INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowFuelLevelAlarm 1.3.6.1.4.1.318.463
WARNING: The tank fuel level is below the limits specified in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured fuel level in percent of full.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowFuelLevelAlarmCleared 1.3.6.1.4.1.318.464
INFORMATIONAL: The tank fuel level is back above the specified limit. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorVeryLowFuelLevelAlarm 1.3.6.1.4.1.318.465
SEVERE: The tank fuel level is below the low threshold limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured tank fuel level in percent of full.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowFuelLevelAlarmCleared 1.3.6.1.4.1.318.466
INFORMATIONAL: The detected low tank level has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorLowRunTimeAlarm 1.3.6.1.4.1.318.467
WARNING: The estimated runtime is below the limits specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorLowRunTimeAlarmCleared 1.3.6.1.4.1.318.468
INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorVeryLowRunTimeAlarm 1.3.6.1.4.1.318.469
SEVERE: The estimated runtime is below the limits specified in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorVeryLowRunTimeAlarmCleared 1.3.6.1.4.1.318.470
INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorServiceDueAlarm 1.3.6.1.4.1.318.471
WARNING: The generator is due for scheduled service. Generation of this alarm is based on calendar days since and/or actual generator run-hours since last service. This alarm is cleared using the xATSGeneratorServiceResetRecord OID. (See also: xATSGeneratorServiceCalendarIntervalThreshold and xATSGeneratorServiceRunHoursThreshold OIDs) The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorServiceDueAlarmCleared 1.3.6.1.4.1.318.472
INFORMATIONAL: The generator's service registers have been reset. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSGeneratorShutdown 1.3.6.1.4.1.318.473
SEVERE: The generator is shutdown. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorShutdownCleared 1.3.6.1.4.1.318.474
INFORMATIONAL: The generator shutdown alarm is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorBatteryCharger 1.3.6.1.4.1.318.475
SEVERE: The generator battery charger is nonfunctional. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorBatteryChargerCleared 1.3.6.1.4.1.318.476
INFORMATIONAL: Fault in the generator battery charger is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorGenericEvent 1.3.6.1.4.1.318.477
WARNING: Any generic generator event. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorGenericEventCleared 1.3.6.1.4.1.318.478
INFORMATIONAL: Generated generic generator event is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUInternalCommErrorCleared 1.3.6.1.4.1.318.479
INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUSystemStateAlarm 1.3.6.1.4.1.318.480
SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead to system unavailability. it may signify a temporary condition, when the breakers are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS) The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUSystemStateAlarmCleared 1.3.6.1.4.1.318.481
INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration that is a non-alarm state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUEpoTestMode 1.3.6.1.4.1.318.482
WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUEpoArmed 1.3.6.1.4.1.318.483
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUFuseBlownAlarm 1.3.6.1.4.1.318.484
SEVERE: One or more fuses in this PDU have been detected as open. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUFuseBlownAlarmCleared 1.3.6.1.4.1.318.485
INFORMATIONAL: A previous check fuse alarm in this PDU has cleared. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUBreakerPositionAlarm 1.3.6.1.4.1.318.486
SEVERE: A PDU breaker is in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm is applicable only for PDUs with no system bypass. The fourth argument is the breaker position (1=OPEN, 2=CLOSED).
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUBreakerPositionAlarmCleared 1.3.6.1.4.1.318.487
INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm cleared is applicable only for PDUs with no system bypass.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xPDUBreakerChangeEvent 1.3.6.1.4.1.318.488
INFORMATIONAL: A system breaker or switch within the device has changed state. They are generated when any of the Q1, Q2 or Q3 breakers have changed states. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker that has changed (1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3). The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED). The fifth argument is a 8-bit field representing the state of all breakers in the system, when any of one of the Q1, Q2 or Q3 breakers have changed state. The bit map is represented in the following manner (b7, b6 ... b0) b0 - UPS FEED (Q1) b1 - MAINTENANCE BYPASS (Q3) b2 - UPS OUTPUT (Q2) b3 - MAIN INPUT b4 - BYPASS INPUT b5 - CROSS-TIE OUTPUT Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers are CLOSED and Q3, Q1 breakers are OPEN.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUDataCommMismatchError 1.3.6.1.4.1.318.489
SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUDataCommMismatchErrorCleared 1.3.6.1.4.1.318.490
INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUSystemInMaintenanceBypassMode 1.3.6.1.4.1.318.491
WARNING: The PDU state has changed to maintenance bypass mode. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xPDUSystemInUPSOperationalMode 1.3.6.1.4.1.318.492
INFORMATIONAL: The PDU state has changed to UPS operational mode. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsString  

xATSGeneratorFuelTankRuptureAlarm 1.3.6.1.4.1.318.493
WARNING: Detected a rupture in the inner wall of the generator fuel tank. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorFuelTankRuptureAlarmCleared 1.3.6.1.4.1.318.494
INFORMATIONAL: The rupture in the inner wall of the generator is not detected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorGroundFaultAlarm 1.3.6.1.4.1.318.495
SEVERE: Generator ground fault alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSGeneratorGroundFaultAlarmCleared 1.3.6.1.4.1.318.496
INFORMATIONAL: Generator ground fault alarm cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSOutputLoadPoweredByGeneratorAlarm 1.3.6.1.4.1.318.497
WARNING: The system load on the output of the ATS is being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name. The third argument indicates if the load is powered by the generator, when 'load testing' the generator (1 = LIVE, 2 = TEST).
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSOutputLoadPoweredByGeneratorAlarmCleared 1.3.6.1.4.1.318.498
INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xAPCControllerFirmwareUpdateTransferStart 1.3.6.1.4.1.318.499
INFORMATIONAL: Start controller firmware transfer in the device. The first argument is the host device serial number. The second argument is the host model name that initiated the transfer. The third argument is the name of the file that is transferred. The fourth argument is the updated revision of the file, if available The fifth argument is the reason for the update, if available (1=User request, 2=Automatic upgrade by NMC, 3=Unknown).
TRAP-TYPE    
  mtrapargsString05  
  mtrapargsString04  
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

xAPCControllerFirmwareUpdateTransferComplete 1.3.6.1.4.1.318.500
INFORMATIONAL: Transfer of controller firmware was completed in the device. The first argument is the host device serial number. The second argument is the host device model name that completed the transfer. The third argument is the name of the file that was transferred. The fourth argument is the revision of the file that was transferred, if available.
TRAP-TYPE    
  mtrapargsString05  
  mtrapargsString04  
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

xAPCControllerFirmwareUpdateTransferFailed 1.3.6.1.4.1.318.501
SEVERE: Transfer of controller firmware failed. The first argument is the host device serial number. The second argument is the host device model name that failed to transfer. The third argument is the name of the file that failed the transfer, if available. The fourth argument is the reason for failure.
TRAP-TYPE    
  mtrapargsString05  
  mtrapargsString04  
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

upsPfcInputRelayFailure 1.3.6.1.4.1.318.502
WARNING: The PFC (Power Factor Correction) input relay failure exists.
TRAP-TYPE    
  mtrapargsString  

upsPfcInputRelayFailureCleared 1.3.6.1.4.1.318.503
INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared.
TRAP-TYPE    
  mtrapargsString  

upsInverterOverTemperature 1.3.6.1.4.1.318.504
WARNING: The inverter over temperature condition exists.
TRAP-TYPE    
  mtrapargsString  

upsInverterOverTemperatureCleared 1.3.6.1.4.1.318.505
INFORMATIONAL: The inverter over temperature condition cleared.
TRAP-TYPE    
  mtrapargsString  

upsBatteryOverVoltage 1.3.6.1.4.1.318.506
WARNING: The battery over voltage condition exists.
TRAP-TYPE    
  mtrapargsString  

upsBatteryOverVoltageCleared 1.3.6.1.4.1.318.507
INFORMATIONAL: The battery over voltage condition cleared.
TRAP-TYPE    
  mtrapargsString  

upsEepromFault 1.3.6.1.4.1.318.508
WARNING: The EEPROM fault exists.
TRAP-TYPE    
  mtrapargsString  

upsEepromFaultCleared 1.3.6.1.4.1.318.509
INFORMATIONAL: The EEPROM fault cleared.
TRAP-TYPE    
  mtrapargsString  

aruFanRuntimeAlarm 1.3.6.1.4.1.318.510
WARNING: The total running hours for a fan has exceeded the run hour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsInteger  
  mtrapargsString  

aruFanRuntimeAlarmCleared 1.3.6.1.4.1.318.511
INFORMATIONAL: The total running hours for a fan is no longer above the fan runhour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsInteger  
  mtrapargsString  

aruFanPoorPerformanceAlarm 1.3.6.1.4.1.318.512
WARNING: Poor fan performance has been detected in the ARU, indicating that the fan may be close to failing. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsInteger  
  mtrapargsString  

aruFanPoorPerformanceAlarmCleared 1.3.6.1.4.1.318.513
INFORMATIONAL: Fan performance is no longer degraded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsInteger  
  mtrapargsString  

aruRedundantPowerLostAlarm 1.3.6.1.4.1.318.514
WARNING: One of the redundant line cords on the ARU is no longer receiving AC power. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

aruRedundantPowerLostAlarmCleared 1.3.6.1.4.1.318.515
INFORMATIONAL: Line-cord redundancy has been restored to the ARU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
TRAP-TYPE    
  emsIdentSerialNumber  
  emsIdentEMSName  
  rARUStatusAruIndex  
  rARUStatusAruName  
  mtrapargsString  

apcDeviceConfigChange 1.3.6.1.4.1.318.516
INFORMATIONAL: A device configuration change has been made on the device. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcEnvSensorConnected 1.3.6.1.4.1.318.517
INFORMATIONAL: A sensor has been connected to the host device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvSensorDisconnected 1.3.6.1.4.1.318.518
SEVERE: A sensor has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMaxTempThresholdViolation 1.3.6.1.4.1.318.519
SEVERE: Max temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMaxTempThresholdViolationCleared 1.3.6.1.4.1.318.520
INFORMATIONAL: Max temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvHighTempThresholdViolation 1.3.6.1.4.1.318.521
WARNING: High temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvHighTempThresholdViolationCleared 1.3.6.1.4.1.318.522
INFORMATIONAL: High temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLowTempThresholdViolation 1.3.6.1.4.1.318.523
WARNING: Low temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLowTempThresholdViolationCleared 1.3.6.1.4.1.318.524
INFORMATIONAL: Low temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMinTempThresholdViolation 1.3.6.1.4.1.318.525
SEVERE: Min temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMinTempThresholdViolationCleared 1.3.6.1.4.1.318.526
INFORMATIONAL: Min temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The sixth argument is the sensor number. The seventh argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvSTIncTempRateViolation 1.3.6.1.4.1.318.527
SEVERE: Short-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvSTIncTempRateViolationCleared 1.3.6.1.4.1.318.528
INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvSTDecTempRateViolation 1.3.6.1.4.1.318.529
SEVERE: Short-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvSTDecTempRateViolationCleared 1.3.6.1.4.1.318.530
INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLTIncTempRateViolation 1.3.6.1.4.1.318.531
SEVERE: Long-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLTIncTempRateViolationCleared 1.3.6.1.4.1.318.532
INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLTDecTempRateViolation 1.3.6.1.4.1.318.533
SEVERE: Long-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLTDecTempRateViolationCleared 1.3.6.1.4.1.318.534
INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMaxHumidityThresholdViolation 1.3.6.1.4.1.318.535
SEVERE: Max humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMaxHumidityThresholdViolationCleared 1.3.6.1.4.1.318.536
INFORMATIONAL: Max humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvHighHumidityThresholdViolation 1.3.6.1.4.1.318.537
WARNING: High humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvHighHumidityThresholdViolationCleared 1.3.6.1.4.1.318.538
INFORMATIONAL: High humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLowHumidityThresholdViolation 1.3.6.1.4.1.318.539
WARNING: Low humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvLowHumidityThresholdViolationCleared 1.3.6.1.4.1.318.540
INFORMATIONAL: Low humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMinHumidityThresholdViolation 1.3.6.1.4.1.318.541
SEVERE: Min humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcEnvMinHumidityThresholdViolationCleared 1.3.6.1.4.1.318.542
INFORMATIONAL: Min humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcBeaconConnected 1.3.6.1.4.1.318.543
INFORMATIONAL: A beacon has been connected to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcBeaconDisconnected 1.3.6.1.4.1.318.544
SEVERE: A beacon has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcBeaconOn 1.3.6.1.4.1.318.545
INFORMATIONAL: A beacon has gone on (activated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcBeaconOff 1.3.6.1.4.1.318.546
INFORMATIONAL: A beacon has gone off (deactivated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcOutletStateAbnormal 1.3.6.1.4.1.318.547
WARNING: An outlet on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcOutletStateNormal 1.3.6.1.4.1.318.548
INFORMATIONAL: An outlet on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcOutputRelayStateAbnormal 1.3.6.1.4.1.318.549
WARNING: An output relay on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcOutputRelayStateNormal 1.3.6.1.4.1.318.550
INFORMATIONAL: An output relay on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcHardwareStateAbnormal 1.3.6.1.4.1.318.551
SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to device ports or Alink Current limit detection. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is a hardware specific state code.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString  

apcHardwareStateNormal 1.3.6.1.4.1.318.552
INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcCriticalDiscreteInputContactStateAbnormal 1.3.6.1.4.1.318.553
SEVERE: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcCriticalDiscreteInputContactStateNormal 1.3.6.1.4.1.318.554
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcWarningDiscreteInputContactStateAbnormal 1.3.6.1.4.1.318.555
WARNING: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcWarningDiscreteInputContactStateNormal 1.3.6.1.4.1.318.556
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcInformationalDiscreteInputContactStateAbnormal 1.3.6.1.4.1.318.557
INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcInformationalDiscreteInputContactStateNormal 1.3.6.1.4.1.318.558
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

apcAnalogInputMaxThresholdViolation 1.3.6.1.4.1.318.559
SEVERE: Maximum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputMaxThresholdViolationCleared 1.3.6.1.4.1.318.560
INFORMATIONAL: Maximum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputHighThresholdViolation 1.3.6.1.4.1.318.561
WARNING: High threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputHighThresholdViolationCleared 1.3.6.1.4.1.318.562
INFORMATIONAL: High threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputLowThresholdViolation 1.3.6.1.4.1.318.563
WARNING: Low threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputLowThresholdViolationCleared 1.3.6.1.4.1.318.564
INFORMATIONAL: Low threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputMinThresholdViolation 1.3.6.1.4.1.318.565
SEVERE: Minimum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcAnalogInputMinThresholdViolationCleared 1.3.6.1.4.1.318.566
INFORMATIONAL: Minimum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcDeviceClearLostComms 1.3.6.1.4.1.318.567
INFORMATIONAL: Lost communications reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

apcDeviceConnected 1.3.6.1.4.1.318.568
INFORMATIONAL: A device has been connected to the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcDeviceDisconnected 1.3.6.1.4.1.318.569
SEVERE: A device has been disconnected from the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

apcUnregisteredUserAccessDenied 1.3.6.1.4.1.318.570
INFORMATIONAL: An unregistered user has tried to access the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the unregistered user's RFID.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString05  
  mtrapargsString  

apcRegisteredUserAccessDenied 1.3.6.1.4.1.318.571
INFORMATIONAL: A registered user has been denied access to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the user name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString05  
  mtrapargsString  

apcRegisteredUserConfigChange 1.3.6.1.4.1.318.572
INFORMATIONAL: Registered user configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsString05  
  mtrapargsString  

apcDoorUnlocked 1.3.6.1.4.1.318.573
INFORMATIONAL: A door has been unlocked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString05  
  mtrapargsInteger02  
  mtrapargsString  

apcDoorLocked 1.3.6.1.4.1.318.574
INFORMATIONAL: A door has been locked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString05  
  mtrapargsInteger02  
  mtrapargsString  

apcHandleOpened 1.3.6.1.4.1.318.575
INFORMATIONAL: A door handle has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcHandleClosed 1.3.6.1.4.1.318.576
INFORMATIONAL: A door handle has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorOpened 1.3.6.1.4.1.318.577
INFORMATIONAL: A door has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorClosed 1.3.6.1.4.1.318.578
INFORMATIONAL: A door has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcKeyOverrideUnlocked 1.3.6.1.4.1.318.580
SEVERE: Key override unlock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcKeyOverrideLocked 1.3.6.1.4.1.318.581
INFORMATIONAL: Key override lock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcForcedEntry 1.3.6.1.4.1.318.582
SEVERE: A forced entry condition has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcForcedEntryCleared 1.3.6.1.4.1.318.583
INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcRelockTimeout 1.3.6.1.4.1.318.584
SEVERE: A relock timout has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcRelockTimeoutCleared 1.3.6.1.4.1.318.585
INFORMATIONAL: A relock timout has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorSenseDisconnected 1.3.6.1.4.1.318.586
SEVERE: A door sensor was disconnected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorSenseConnected 1.3.6.1.4.1.318.587
INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorLostComms 1.3.6.1.4.1.318.588
SEVERE: Communications have been lost with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorEstablishedComms 1.3.6.1.4.1.318.589
INFORMATIONAL: Communications have been established with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcRegisteredUserAccessChange 1.3.6.1.4.1.318.590
INFORMATIONAL: Registered user access changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsString05  
  mtrapargsString  

apcUnregisteredUserStatusChange 1.3.6.1.4.1.318.591
INFORMATIONAL: Unregistered user status changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsString05  
  mtrapargsString  

apcDeviceClearUserConfigs 1.3.6.1.4.1.318.592
INFORMATIONAL: User configurations reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger04  
  mtrapargsString  

upsBatteryTempSensorFault 1.3.6.1.4.1.318.600
WARNING: The battery temperature sensor fault exists.
TRAP-TYPE    
  mtrapargsString  

upsBatteryTempSensorFaultCleared 1.3.6.1.4.1.318.601
INFORMATIONAL: The battery temperature sensor fault cleared.
TRAP-TYPE    
  mtrapargsString  

upsBatterySoftBusStartFault 1.3.6.1.4.1.318.602
WARNING: A battery bus soft start fault exists.
TRAP-TYPE    
  mtrapargsString  

upsBatterySoftBusStartFaultCleared 1.3.6.1.4.1.318.603
INFORMATIONAL: A battery bus soft start fault exists cleared.
TRAP-TYPE    
  mtrapargsString  

apcOutputShortCircuit 1.3.6.1.4.1.318.604
WARNING: An output short circuit condition exists.
TRAP-TYPE    
  mtrapargsString  

apcOutputShortCircuitCleared 1.3.6.1.4.1.318.605
INFORMATIONAL: An output short circuit condition cleared.
TRAP-TYPE    
  mtrapargsString  

apcOutputRelayFault 1.3.6.1.4.1.318.606
WARNING: An output relay (or its driver) fault exists.
TRAP-TYPE    
  mtrapargsString  

apcOutputRelayFaultCleared 1.3.6.1.4.1.318.607
INFORMATIONAL: An output relay (or its driver) fault cleared.
TRAP-TYPE    
  mtrapargsString  

upsPfcFault 1.3.6.1.4.1.318.608
WARNING: A PFC fault exists.
TRAP-TYPE    
  mtrapargsString  

upsPfcFaultCleared 1.3.6.1.4.1.318.609
INFORMATIONAL: The PFC fault cleared.
TRAP-TYPE    
  mtrapargsString  

apcDcBusOverVoltage 1.3.6.1.4.1.318.610
WARNING: The DC bus voltage is too high.
TRAP-TYPE    
  mtrapargsString  

apcDcBusOverVoltageCleared 1.3.6.1.4.1.318.611
INFORMATIONAL: The DC bus voltage is too high cleared.
TRAP-TYPE    
  mtrapargsString  

upsInverterFault 1.3.6.1.4.1.318.612
WARNING: The inverter fault exists.
TRAP-TYPE    
  mtrapargsString  

upsInverterFaultCleared 1.3.6.1.4.1.318.613
INFORMATIONAL: The inverter fault cleared.
TRAP-TYPE    
  mtrapargsString  

apcAdConverterFault 1.3.6.1.4.1.318.614
WARNING: The A/D converter fault exists.
TRAP-TYPE    
  mtrapargsString  

apcAdConverterFaultCleared 1.3.6.1.4.1.318.615
INFORMATIONAL: The A/D converter fault cleared.
TRAP-TYPE    
  mtrapargsString  

apcLogicPowerSupplyFault 1.3.6.1.4.1.318.616
WARNING: A logic power supply fault exists.
TRAP-TYPE    
  mtrapargsString  

apcLogicPowerSupplyFaultCleared 1.3.6.1.4.1.318.617
INFORMATIONAL: A logic power supply fault cleared.
TRAP-TYPE    
  mtrapargsString  

apcTransformerDCImbalanceFault 1.3.6.1.4.1.318.618
WARNING: The DC component of the transformer's current is too high.
TRAP-TYPE    
  mtrapargsString  

apcTransformerDCImbalanceFaultCleared 1.3.6.1.4.1.318.619
WARNING: The DC component of the transformer's current is normal.
TRAP-TYPE    
  mtrapargsString  

upsBackfeedRelayFault 1.3.6.1.4.1.318.620
WARNING: The backfeed relay (or its driver) has a fault.
TRAP-TYPE    
  mtrapargsString  

upsBackfeedRelayFaultCleared 1.3.6.1.4.1.318.621
WARNING: The backfeed relay (or its driver) has a fault cleared.
TRAP-TYPE    
  mtrapargsString  

upsBypassRelayFault 1.3.6.1.4.1.318.622
WARNING: A bypass relay (or its driver) has a fault.
TRAP-TYPE    
  mtrapargsString  

upsBypassRelayFaultCleared 1.3.6.1.4.1.318.623
WARNING: A bypass relay (or its driver) has a fault cleared.
TRAP-TYPE    
  mtrapargsString  

xPDUBranchCurrentMinAlarm 1.3.6.1.4.1.318.626
SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBranchCurrentMinAlarmCleared 1.3.6.1.4.1.318.627
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

xPDUBranchCurrentMaxAlarm 1.3.6.1.4.1.318.628
SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

xPDUBranchCurrentMaxAlarmCleared 1.3.6.1.4.1.318.629
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
TRAP-TYPE    
  xPDUIdentSerialNumber  
  xPDUIdentProductName  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsString  

rPDUOutletLowLoad 1.3.6.1.4.1.318.630
WARNING: A Rack PDU has violated the outlet low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

rPDUOutletLowLoadCleared 1.3.6.1.4.1.318.631
INFORMATIONAL: The outlet low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

rPDUOutletNearOverload 1.3.6.1.4.1.318.632
WARNING: A Rack PDU is near an outlet overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

rPDUOutletNearOverloadCleared 1.3.6.1.4.1.318.633
INFORMATIONAL: The outlet near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

rPDUOutletOverload 1.3.6.1.4.1.318.634
SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

rPDUOutletOverloadCleared 1.3.6.1.4.1.318.635
INFORMATIONAL: The outlet overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
TRAP-TYPE    
  rPDUIdentSerialNumber  
  rPDUIdentName  
  rPDUOutletStatusIndex  
  mtrapargsString  

apcTestTrap 1.3.6.1.4.1.318.636
INFORMATIONAL: Trap used to test SNMP trap functionality. The first argument is a place holder for test variables.
TRAP-TYPE    
  mtrapargsInteger02  
  mtrapargsString  

baseFanFailureCleared 1.3.6.1.4.1.318.637
INFORMATIONAL: Base module fan has been repaired
TRAP-TYPE    
  mtrapargsString  

atsLowLoad 1.3.6.1.4.1.318.638
WARNING: ATS has violated the bank or phase low load threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsLowLoadCleared 1.3.6.1.4.1.318.639
INFORMATIONAL: The bank or phase low load condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsNearOverload 1.3.6.1.4.1.318.640
WARNING: ATS has violated the bank or phase near overload threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsNearOverloadCleared 1.3.6.1.4.1.318.641
INFORMATIONAL: The bank or phase near overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsOverload 1.3.6.1.4.1.318.642
SEVERE: ATS is in an overload condition. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsOverloadCleared 1.3.6.1.4.1.318.643
INFORMATIONAL: The bank or phase overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  atsOutputPhaseIndex  
  atsOutputBank  
  mtrapargsString  

atsRMSOverVoltage 1.3.6.1.4.1.318.644
SEVERE: Overvoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSOverVoltageCleared 1.3.6.1.4.1.318.645
INFORMATIONAL: Overvoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSUnderVoltage 1.3.6.1.4.1.318.646
SEVERE: Undervoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSUnderVoltageCleared 1.3.6.1.4.1.318.647
INFORMATIONAL: Undervoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSOverFrequency 1.3.6.1.4.1.318.648
SEVERE: OverFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSOverFrequencyCleared 1.3.6.1.4.1.318.649
INFORMATIONAL: OverFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSUnderFrequency 1.3.6.1.4.1.318.650
SEVERE: UnderFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsRMSUnderFrequencyCleared 1.3.6.1.4.1.318.651
INFORMATIONAL: UnderFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

isxModularDistributionCommLost 1.3.6.1.4.1.318.652
SEVERE: Communication with a metering segment of the modular distribution system has been lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

isxModularDistributionCommEstablished 1.3.6.1.4.1.318.653
INFORMATIONAL: Communication with a metering segment of the modular distribution system has been restored. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

isxModularDistributionModuleInserted 1.3.6.1.4.1.318.654
INFORMATIONAL: A distribution module has been inserted into the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularDistributionModuleRemoved 1.3.6.1.4.1.318.655
INFORMATIONAL: A distribution module has been removed from the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularBreakerOpenAlarm 1.3.6.1.4.1.318.656
SEVERE: A distribution module breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the module breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularBreakerOpenAlarmCleared 1.3.6.1.4.1.318.657
INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularMinCurrentThresholdViolation 1.3.6.1.4.1.318.658
SEVERE: The current in a distribution module is below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularMinCurrentThresholdViolationCleared 1.3.6.1.4.1.318.659
INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularLowCurrentThresholdViolation 1.3.6.1.4.1.318.660
WARNING: The current in a distribution module is below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularLowCurrentThresholdViolationCleared 1.3.6.1.4.1.318.661
INFORMATIONAL: The current in a distribution module is no longer below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularHighCurrentThresholdViolation 1.3.6.1.4.1.318.662
WARNING: The current in a distribution module is above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularHighCurrentThresholdViolationCleared 1.3.6.1.4.1.318.663
INFORMATIONAL: The current in a distribution module is no longer above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularMaxCurrentThresholdViolation 1.3.6.1.4.1.318.664
SEVERE: The current in a distribution module is above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularMaxCurrentThresholdViolationCleared 1.3.6.1.4.1.318.665
INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedBreakerOpenAlarm 1.3.6.1.4.1.318.666
SEVERE: A distribution subfeed breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedBreakerOpenAlarmCleared 1.3.6.1.4.1.318.667
INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedMinCurrentThresholdViolation 1.3.6.1.4.1.318.668
SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedMinCurrentThresholdViolationCleared 1.3.6.1.4.1.318.669
INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedLowCurrentThresholdViolation 1.3.6.1.4.1.318.670
WARNING: The current in a distribution subfeed is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedLowCurrentThresholdViolationCleared 1.3.6.1.4.1.318.671
INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedHighCurrentThresholdViolation 1.3.6.1.4.1.318.672
WARNING: The current in a distribution subfeed is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedHighCurrentThresholdViolationCleared 1.3.6.1.4.1.318.673
INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedMaxCurrentThresholdViolation 1.3.6.1.4.1.318.674
SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsInteger02  
  mtrapargsString04  
  mtrapargsString  

isxModularSubfeedMaxCurrentThresholdViolationCleared 1.3.6.1.4.1.318.675
INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString04  
  mtrapargsString  

isxModularTotalOutputCurrentMinThresholdViolation 1.3.6.1.4.1.318.676
SEVERE: The total output current of the distribution is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularTotalOutputCurrentMinThresholdViolationCleared 1.3.6.1.4.1.318.677
INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularTotalOutputCurrentLowThresholdViolation 1.3.6.1.4.1.318.678
WARNING: The total output current of the distribution is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularTotalOutputCurrentLowThresholdViolationCleared 1.3.6.1.4.1.318.679
INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularTotalOutputCurrentHighThresholdViolation 1.3.6.1.4.1.318.680
WARNING: The total output current of the distribution is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularTotalOutputCurrentHighThresholdViolationCleared 1.3.6.1.4.1.318.681
INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularTotalOutputCurrentMaxThresholdViolation 1.3.6.1.4.1.318.682
SEVERE: The total output current of the distribution is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularTotalOutputCurrentMaxThresholdViolationCleared 1.3.6.1.4.1.318.683
INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputVoltageMinThresholdViolation 1.3.6.1.4.1.318.684
SEVERE: The distribution output voltage is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularOutputVoltageMinThresholdViolationCleared 1.3.6.1.4.1.318.685
INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputVoltageLowThresholdViolation 1.3.6.1.4.1.318.686
WARNING: The distribution output voltage is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularOutputVoltageLowThresholdViolationCleared 1.3.6.1.4.1.318.687
INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputVoltageHighThresholdViolation 1.3.6.1.4.1.318.688
WARNING: The distribution output voltage is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularOutputVoltageHighThresholdViolationCleared 1.3.6.1.4.1.318.689
INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputVoltageMaxThresholdViolation 1.3.6.1.4.1.318.690
SEVERE: The distribution output voltage is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger03  
  mtrapargsString  

isxModularOutputVoltageMaxThresholdViolationCleared 1.3.6.1.4.1.318.691
INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

apcDoorClosedImproperly 1.3.6.1.4.1.318.692
SEVERE: A door has been closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcDoorClosedImproperlyCleared 1.3.6.1.4.1.318.693
INFORMATIONAL: A door is no longer closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcUserScheduleViolation 1.3.6.1.4.1.318.694
SEVERE: A user has had a door opened past the scheduled access period. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

apcUserScheduleViolationCleared 1.3.6.1.4.1.318.695
INFORMATIONAL: User schedule violation has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString04  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputFrequencyThresholdViolation 1.3.6.1.4.1.318.696
SEVERE: The distribution output frequency is outside of the operating range specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the threshold, in tenths of Hertz, from which the alarm was generated.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsString  

isxModularOutputFrequencyViolationCleared 1.3.6.1.4.1.318.697
INFORMATIONAL: The distribution output frequency is no longer out of range. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

atsSourceStatusFail 1.3.6.1.4.1.318.698
SEVERE: ATS Source failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsSourceStatusOk 1.3.6.1.4.1.318.699
INFORMATIONAL: ATS Source OK. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsHardwareStatusFail 1.3.6.1.4.1.318.700
SEVERE: ATS display board hardware failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the failed hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsHardwareStatusOk 1.3.6.1.4.1.318.701
INFORMATIONAL: ATS display board hardware ok. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure.
TRAP-TYPE    
  atsIdentSerialNumber  
  atsConfigProductName  
  mtrapargsInteger  
  mtrapargsString  

atsControllerRestart 1.3.6.1.4.1.318.702
INFORMATIONAL: ATS Controller restarted.
TRAP-TYPE    
  mtrapargsString  

xATSS1BadPhaseRotation 1.3.6.1.4.1.318.724
SEVERE: The device's source 1 phase rotation is bad. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSS1BadPhaseRotationCleared 1.3.6.1.4.1.318.725
INFORMATIONAL: The device's source 1 phase rotation is back to normal. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

xATSS1BadPhaseBalance 1.3.6.1.4.1.318.726
SEVERE: The device's source 1 phase balance is out of bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the minimum phase balance as a percentage.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsInteger  
  mtrapargsString  

xATSS1BadPhaseBalanceCleared 1.3.6.1.4.1.318.727
INFORMATIONAL: The device's source 1 phase balance is back to normal. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  xATSIdentSerialNumber  
  xATSIdentProductName  
  mtrapargsString  

isxModularTransformerOverheating 1.3.6.1.4.1.318.728
SEVERE: The distribution transformer temperature is too hot. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

isxModularTransformerOverheatingCleared 1.3.6.1.4.1.318.729
INFORMATIONAL: The distribution transformer temperature has returned to normal. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

apcInternalCommunicationFault 1.3.6.1.4.1.318.730
SEVERE: An internal UPS communication fault exists.
TRAP-TYPE    
  mtrapargsString  

apcInternalCommunicationFaultCleared 1.3.6.1.4.1.318.731
INFORMATIONAL: An internal UPS communication fault no longer exists.
TRAP-TYPE    
  mtrapargsString  

upsOutletGroupCommand 1.3.6.1.4.1.318.732
WARNING: The specified Outlet Group command has been issued.
TRAP-TYPE    
  upsOutletGroupControlIndex  
  mtrapargsString  

onbatterycommunicationLost 1.3.6.1.4.1.318.733
SEVERE: Communication to the UPS when the UPS is on Battery. Steps to reestablish communication are in progress.
TRAP-TYPE    
  mtrapargsString  

upsCriticalCondition 1.3.6.1.4.1.318.734
SEVERE: A UPS critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsCriticalConditionCleared 1.3.6.1.4.1.318.735
INFORMATIONAL: A UPS critical condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsWarningCondition 1.3.6.1.4.1.318.736
WARNING: A UPS warning condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsWarningConditionCleared 1.3.6.1.4.1.318.737
WARNING: A UPS warning condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsInformationalCondition 1.3.6.1.4.1.318.738
INFORMATIONAL: A UPS informational condition has been detected. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

upsInformationalConditionCleared 1.3.6.1.4.1.318.739
INFORMATIONAL: A UPS informational condition has been cleared. The first variable is the fault condition.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsInteger  
  mtrapargsString  

isxcInformationalAlarm 1.3.6.1.4.1.318.740
INFORMATIONAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcInformationalAlarmCleared 1.3.6.1.4.1.318.741
INFORMATIONAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcWarningAlarm 1.3.6.1.4.1.318.742
WARNING: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcWarningAlarmCleared 1.3.6.1.4.1.318.743
WARNING: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcErrorAlarm 1.3.6.1.4.1.318.744
ERROR: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcErrorAlarmCleared 1.3.6.1.4.1.318.745
ERROR: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcCriticalAlarm 1.3.6.1.4.1.318.746
CRITICAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcCriticalAlarmCleared 1.3.6.1.4.1.318.747
CRITICAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcFailureAlarm 1.3.6.1.4.1.318.748
FAILURE: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

isxcFailureAlarmCleared 1.3.6.1.4.1.318.749
FAILURE: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsOctetString  
  mtrapargsInteger  
  mtrapargsString03  
  mtrapargsOctetString02  
  mtrapargsString04  
  mtrapargsOctetString03  
  mtrapargsString05  
  mtrapargsString06  
  mtrapargsString07  
  mtrapargsOctetString04  
  mtrapargsOctetString05  
  mtrapargsString08  
  mtrapargsOctetString06  
  mtrapargsOctetString07  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsOctetString08  
  mtrapargsString  

rpduCriticalCondition 1.3.6.1.4.1.318.750
SEVERE: A RPDU critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

rpduCriticalConditionCleared 1.3.6.1.4.1.318.751
INFORMATIONAL: A RPDU critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

rpduWarningCondition 1.3.6.1.4.1.318.752
WARNING: A RPDU warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

rpduWarningConditionCleared 1.3.6.1.4.1.318.753
WARNING: A RPDU warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

rpduInformationalCondition 1.3.6.1.4.1.318.754
INFORMATIONAL: A RPDU informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

rpduInformationalConditionCleared 1.3.6.1.4.1.318.755
INFORMATIONAL: A RPDU informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsInteger  
  mtrapargsInteger02  
  mtrapargsInteger03  
  mtrapargsString  

isxModularCoolingFanAlarm 1.3.6.1.4.1.318.756
SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

isxModularCoolingFanAlarmCleared 1.3.6.1.4.1.318.757
INFORMATIONAL: The device's internal cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name.
TRAP-TYPE    
  mtrapargsString02  
  mtrapargsString03  
  mtrapargsString  

upsFirmwareUpdateStarted 1.3.6.1.4.1.318.758
WARNING: Updating UPS firmware.
TRAP-TYPE    
  mtrapargsString  

upsFirmwareUpdateFinished 1.3.6.1.4.1.318.759
INFORMATIONAL: Finished updating UPS firmware.
TRAP-TYPE    
  mtrapargsString  

upsFirmwareUpdateSucceeded 1.3.6.1.4.1.318.760
INFORMATIONAL: UPS firmware update succeeded.
TRAP-TYPE    
  mtrapargsString  

upsFirmwareUpdateFailed 1.3.6.1.4.1.318.761
WARNING: UPS firmware update failed.
TRAP-TYPE    
  mtrapargsString  

upsHasNoValidFirmware 1.3.6.1.4.1.318.762
SEVERE: UPS has no valid firmware.
TRAP-TYPE    
  mtrapargsString  

upsHasNoValidFirmwareCleared 1.3.6.1.4.1.318.763
INFORMATIONAL: UPS now has a valid firmware.
TRAP-TYPE    
  mtrapargsString  

Defined Objects

MconfigTrapReceiverEntry  
SEQUENCE    
  INTEGER as trapIndex  
  IpAddress as receiverAddr  
  DisplayString as communityString  
  INTEGER as severity  
  INTEGER as acceptThisReceiver  
  INTEGER as receiveTrapType  

BattManUnitCalibEntry  
SEQUENCE    
  INTEGER as battManUnitCalibIndex  
  DisplayString as battManUnitSerialNumber  
  INTEGER as battManBatteryVoltageZeroCalib  
  INTEGER as battManBatteryVoltageSpanCalib  

BattManStringCalibEntry  
SEQUENCE    
  INTEGER as battManStringCalibIndex  
  INTEGER as battManDCCurrentZeroCalib  
  INTEGER as battManACCurrentZeroCalib  
  INTEGER as battManProbeRange  

BattManString1BatteryCalibEntry  
SEQUENCE    
  INTEGER as battManString1BatteryCalibIndex  
  INTEGER as battManString1BatteryInterTierOhmicValue  

BattManString2BatteryCalibEntry  
SEQUENCE    
  INTEGER as battManString2BatteryCalibIndex  
  INTEGER as battManString2BatteryInterTierOhmicValue  

BattManInputContactEntry  
SEQUENCE    
  INTEGER as battManInputContactIndex  
  DisplayString as battManInputContactName  
  INTEGER as battManInputContactAlarmState  
  INTEGER as battManInputContactState  
  INTEGER as battManInputContactNormalState  
  INTEGER as battManInputContactAlarmDelay  

BattManStringEntry  
SEQUENCE    
  INTEGER as battManStringIndex  
  INTEGER as battManStringCurrent  
  INTEGER as battManStringRippleCurrent  
  INTEGER as battManStringChargerHighVoltageAlarm  
  INTEGER as battManStringChargerLowVoltageAlarm  
  INTEGER as battManStringCurrentProbeDisconnected  
  INTEGER as battManStringOnBattery  
  INTEGER as battManStringHighRippleCurrent  
  INTEGER as battManStringVoltage  
  INTEGER as battManStringDischargeLess5Seconds  
  INTEGER as battManStringDischarge5to10Seconds  
  INTEGER as battManStringDischarge10to60Seconds  
  INTEGER as battManStringDischargeMore60Seconds  

BattManString1BatteryEntry  
SEQUENCE    
  INTEGER as battManString1BatteryIndex  
  INTEGER as battManString1BatteryVoltage  
  INTEGER as battManString1BatteryLowestVoltage  
  INTEGER as battManString1BatteryCellShorted  
  INTEGER as battManString1BatteryOpenFuseOrConnection  
  INTEGER as battManString1BatteryLowCapacity  
  INTEGER as battManString1BatteryHighOhmicValue  
  INTEGER as battManString1BatteryThermalRunaway  
  INTEGER as battManString1BatteryDryout  
  INTEGER as battManString1BatteryUserHighVoltageAlarm  
  INTEGER as battManString1BatteryUserLowVoltageAlarm  
  INTEGER as battManString1BatteryChemHighVoltageAlarm  
  INTEGER as battManString1BatteryChemLowVoltageAlarm  
  INTEGER as battManString1BatteryOpenCell  

BattManString2BatteryEntry  
SEQUENCE    
  INTEGER as battManString2BatteryIndex  
  INTEGER as battManString2BatteryVoltage  
  INTEGER as battManString2BatteryLowestVoltage  
  INTEGER as battManString2BatteryCellShorted  
  INTEGER as battManString2BatteryOpenFuseOrConnection  
  INTEGER as battManString2BatteryLowCapacity  
  INTEGER as battManString2BatteryHighOhmicValue  
  INTEGER as battManString2BatteryThermalRunaway  
  INTEGER as battManString2BatteryDryout  
  INTEGER as battManString2BatteryUserHighVoltageAlarm  
  INTEGER as battManString2BatteryUserLowVoltageAlarm  
  INTEGER as battManString2BatteryChemHighVoltageAlarm  
  INTEGER as battManString2BatteryChemLowVoltageAlarm  
  INTEGER as battManString2BatteryOpenCell  

BattManString1OhmicValueEntry  
SEQUENCE    
  INTEGER as battManString1OhmicValueIndex  
  INTEGER as battManString1OhmicValueData  

BattManString1ResponseTestChangeEntry  
SEQUENCE    
  INTEGER as battManString1ResponseTestChangeIndex  
  INTEGER as battManString1ResponseTestChangeData  

BattManString2OhmicValueEntry  
SEQUENCE    
  INTEGER as battManString2OhmicValueIndex  
  INTEGER as battManString2OhmicValueData  

BattManString2ResponseTestChangeEntry  
SEQUENCE    
  INTEGER as battManString2ResponseTestChangeIndex  
  INTEGER as battManString2ResponseTestChangeData  

BattManUnitStatusEntry  
SEQUENCE    
  INTEGER as battManUnitStatusIndex  
  DisplayString as battManUnitStatusSerialNumber  
  INTEGER as battManUnitHardwareRev  
  INTEGER as battManUnitFirmwareRev  
  INTEGER as battManUnitCommLoss  
  INTEGER as battManUnitRelayStuck  

XPDUMainInputVoltagePhaseEntry  
SEQUENCE    
  INTEGER as xPDUMainInputVoltagePhaseIndex  
  INTEGER as xPDUMainInputVoltageLtoL  
  INTEGER as xPDUMainInputVoltageLtoN  

XPDUBypassInputVoltagePhaseEntry  
SEQUENCE    
  INTEGER as xPDUBypassInputVoltagePhaseIndex  
  INTEGER as xPDUBypassInputVoltageLtoL  
  INTEGER as xPDUBypassInputVoltageLtoN  

XPDUUPSInputVoltagePhaseEntry  
SEQUENCE    
  INTEGER as xPDUUPSInputVoltagePhaseIndex  
  INTEGER as xPDUUPSInputVoltageLtoNPresent  

XPDUSystemOutputPhaseEntry  
SEQUENCE    
  INTEGER as xPDUSystemOutputPhaseIndex  
  INTEGER as xPDUSystemOutputVoltageLtoL  
  INTEGER as xPDUSystemOutputVoltageLtoN  
  INTEGER as xPDUSystemOutputPhaseCurrent  
  INTEGER as xPDUSystemOutputPower  
  INTEGER as xPDUSystemOutputApparentPower  
  INTEGER as xPDUSystemOutputPowerFactor  

XPDUSystemBreakerEntry  
SEQUENCE    
  INTEGER as xPDUSystemBreakerTableIndex  
  DisplayString as xPDUSystemBreakerDescription  
  INTEGER as xPDUSystemBreakerPosition  

XPDUBranchBreakerEntry  
SEQUENCE    
  INTEGER as xPDUBranchBreakerTableIndex  
  INTEGER as xPDUBranchBreakerRating  
  INTEGER as xPDUBranchBreakerRDPFeed  
  INTEGER as xPDUBranchBreakerTieIndicator  
  INTEGER as xPDUBranchBreakerCurrent  
  INTEGER as xPDUBranchBreakerOverCurrentThreshold  
  INTEGER as xPDUBranchBreakerUnderCurrentThreshold  
  INTEGER as xPDUBranchBreakerMaxCurrentThreshold  
  INTEGER as xPDUBranchBreakerMinCurrentThreshold  
  DisplayString as xPDUBranchBreakerName  
  DisplayString as xPDUBranchBreakerLocation  

XPDUInputContactEntry  
SEQUENCE    
  INTEGER as xPDUInputContactNumber  
  DisplayString as xPDUInputContactName  
  INTEGER as xPDUInputContactNormalState  
  INTEGER as xPDUInputContactCurrentState  

XPDUOutputRelayEntry  
SEQUENCE    
  INTEGER as xPDUOutputRelayNumber  
  DisplayString as xPDUOutputRelayName  
  INTEGER as xPDUOutputRelayNormalState  
  INTEGER as xPDUOutputRelayCurrentState  

XATSSwitchTimersEntry  
SEQUENCE    
  INTEGER as xATSSwitchTimersIndex  
  DisplayString as xATSSwitchTimersName  
  INTEGER as xATSSwitchTimersAbort  
  INTEGER as xATSSwitchTimersStatus  
  INTEGER as xATSSwitchTimersRemainingTime  
  INTEGER as xATSSwitchTimersDelaySetting  

XATSSwitchBlockMapEntry  
SEQUENCE    
  INTEGER as xATSSwitchBlockMapIndex  
  DisplayString as xATSSwitchBlockMapName  
  INTEGER as xATSSwitchBlockMapStatus  
  INTEGER as xATSSwitchBlockMapSetting  

XATSSwitchStatisticsEntry  
SEQUENCE    
  INTEGER as xATSSwitchStatisticsIndex  
  DisplayString as xATSSwitchStatisticsName  
  DisplayString as xATSSwitchStatisticsValue  
  INTEGER as xATSSwitchStatisticsReset  

XATSSource1PhaseEntry  
SEQUENCE    
  INTEGER as xATSSource1Index  
  INTEGER as xATSSource1VoltageLtoL  
  INTEGER as xATSSource1VoltageLtoN  

XATSSource2PhaseEntry  
SEQUENCE    
  INTEGER as xATSSource2Index  
  INTEGER as xATSSource2VoltageLtoL  
  INTEGER as xATSSource2VoltageLtoN  

XATSSystemOutputPhaseEntry  
SEQUENCE    
  INTEGER as xATSSystemOutputPhaseIndex  
  INTEGER as xATSSystemOutputVoltageLtoL  
  INTEGER as xATSSystemOutputVoltageLtoN  
  INTEGER as xATSSystemOutputPhaseCurrent  
  INTEGER as xATSSystemOutputPower  
  INTEGER as xATSSystemOutputApparentPower  
  INTEGER as xATSSystemOutputPowerFactor  

XATSInputContactEntry  
SEQUENCE    
  INTEGER as xATSInputContactNumber  
  DisplayString as xATSInputContactName  
  INTEGER as xATSInputContactNormalState  
  INTEGER as xATSInputContactCurrentState  

XATSOutputRelayEntry  
SEQUENCE    
  INTEGER as xATSOutputRelayNumber  
  DisplayString as xATSOutputRelayName  
  INTEGER as xATSOutputRelayNormalState  
  INTEGER as xATSOutputRelayCurrentState  

XATSGeneratorOutputPhaseEntry  
SEQUENCE    
  INTEGER as xATSGeneratorOutputPhaseIndex  
  INTEGER as xATSGeneratorOutputVoltageLtoL  
  INTEGER as xATSGeneratorOutputVoltageLtoN  
  INTEGER as xATSGeneratorOutputPhaseCurrent  
  INTEGER as xATSGeneratorOutputPower  
  INTEGER as xATSGeneratorOutputApparentPower  
  INTEGER as xATSGeneratorOutputPowerFactor  

CpsCardIdentEntry  
SEQUENCE    
  Integer32 as cpsCardIdentIndex  
  DisplayString as cpsCardIdentProd  
  DisplayString as cpsCardIdentMan  
  DisplayString as cpsCardIdentFunc  
  DisplayString as cpsCardIdentPCI  

CpsCardConfEntry  
SEQUENCE    
  Integer32 as cpsCardConfIndex  
  DisplayString as cpsCardConfPower  
  DisplayString as cpsCardConfType  
  DisplayString as cpsCardConfInter  
  DisplayString as cpsCardConfFunc  
  DisplayString as cpsCardConfCardv  
  DisplayString as cpsCardConfPort1  
  DisplayString as cpsCardConfPort2  

CpsCardStatusEntry  
SEQUENCE    
  Integer32 as cpsCardStatusIndex  
  DisplayString as cpsCardStatusCard  
  DisplayString as cpsCardStatusFunc  

CpsSerialGroupEntry  
SEQUENCE    
  INTEGER as cpsSerialGroupIndex  
  DisplayString as cpsSerialGroupName  
  DisplayString as cpsSerialGroupUsers  

CpsSerialPortEntry  
SEQUENCE    
  INTEGER as cpsSerialPortNumber  
  DisplayString as cpsSerialPortTty  
  DisplayString as cpsSerialPortName  
  Integer32 as cpsSerialPortSpeed  
  Integer32 as cpsSerialPortDataSize  
  Integer32 as cpsSerialPortStopBits  
  DisplayString as cpsSerialPortParity  
  DisplayString as cpsSerialPortFlowCtrl  
  Integer32 as cpsSerialPortDTRdelay  
  INTEGER as cpsSerialPortDCDCtrl  
  INTEGER as cpsSerialPortLogUtmp  
  INTEGER as cpsSerialPortLogWtmp  
  DisplayString as cpsSerialPortLogform  
  DisplayString as cpsSerialPortAuthtype  
  IpAddress as cpsSerialPortAuthSrv1  
  IpAddress as cpsSerialPortAccSrv1  
  Integer32 as cpsSerialPortAuthTmo  
  Integer32 as cpsSerialPortAuthRetr  
  IpAddress as cpsSerialPortAuthSrv2  
  IpAddress as cpsSerialPortAccSrv2  
  DisplayString as cpsSerialPortAuthSecret  
  INTEGER as cpsSerialPortAuthRadP  
  DisplayString as cpsSerialPortAuthAcc  
  DisplayString as cpsSerialPortProtocol  
  DisplayString as cpsSerialPortRemoteIP  
  DisplayString as cpsSerialPortSocketPort  
  IpAddress as cpsSerialPortRemHost  
  DisplayString as cpsSerialPortBanner  
  DisplayString as cpsSerialPortPrompt  
  DisplayString as cpsSerialPortTermType  
  DisplayString as cpsSerialPortAutomUsr  
  IpAddress as cpsSerialPortNetMask  
  Integer32 as cpsSerialPortPppMtu  
  Integer32 as cpsSerialPortPppMru  
  DisplayString as cpsSerialPortPppOptions  
  DisplayString as cpsSerialPortPppFoption  
  DisplayString as cpsSerialPortModemChat  
  DisplayString as cpsSerialPortSttyCmd  
  Integer32 as cpsSerialPortSockTx  
  Integer32 as cpsSerialPortSockPoll  
  Integer32 as cpsSerialPortSockIdle  
  Integer32 as cpsSerialPortDBsize  
  INTEGER as cpsSerialPortDBtime  
  DisplayString as cpsSerialPortDBmode  
  Integer32 as cpsSerialPortDBsyslog  
  INTEGER as cpsSerialPortDBmenu  
  INTEGER as cpsSerialPortDBalarm  
  DisplayString as cpsSerialPortSSHbreak  
  DisplayString as cpsSerialPortSniffSess  
  DisplayString as cpsSerialPortSniffAdm  
  DisplayString as cpsSerialPortSniffEsc  
  DisplayString as cpsSerialPortSniffMsess  
  INTEGER as cpsSerialPortTelnetMode  
  INTEGER as cpsSerialPortSysBufSess  
  INTEGER as cpsSerialPortLFSuppress  
  DisplayString as cpsSerialPortAutoInput  
  DisplayString as cpsSerialPortAutoOutput  
  Integer32 as cpsSerialPortBreakInterval  

CpsInfoSerialPortEntry  
SEQUENCE    
  INTEGER as cpsInfoSerialPortNumber  
  DisplayString as cpsInfoSerialPortTty  
  DisplayString as cpsInfoSerialPortName  
  Integer32 as cpsInfoSerialPortSpeed  
  Integer32 as cpsInfoSerialPortTxBytes  
  Integer32 as cpsInfoSerialPortRXBytes  
  Integer32 as cpsInfoSerialPortErrFrame  
  Integer32 as cpsInfoSerialPortErrParity  
  Integer32 as cpsInfoSerialPortErrBreaks  
  Integer32 as cpsInfoSerialPortErrOverrun  
  INTEGER as cpsInfoSerialPortSigDTR  
  INTEGER as cpsInfoSerialPortSigCD  
  INTEGER as cpsInfoSerialPortSigDSR  
  INTEGER as cpsInfoSerialPortSigRTS  
  INTEGER as cpsInfoSerialPortSigCTS  
  INTEGER as cpsInfoSerialPortSigRI  

PowerNetSoftwareEntry  
SEQUENCE    
  INTEGER as moduleNumber  
  DisplayString as moduleName  
  DisplayString as moduleVersion  
  DisplayString as moduleDate  

UPSAdvBatteryActualVoltageEntry  
SEQUENCE    
  INTEGER as upsAdvBatteryActualVoltageTableIndex  
  INTEGER as upsAdvBatteryActualVoltagePolarity  
  INTEGER as upsAdvBatteryFrameActualVoltage  

UPSAdvTotalDCCurrentEntry  
SEQUENCE    
  INTEGER as upsAdvTotalDCCurrentTableIndex  
  INTEGER as upsAdvTotalDCCurrentPolarity  
  INTEGER as upsAdvTotalFrameDCCurrent  

UPSAdvBatteryCurrentEntry  
SEQUENCE    
  INTEGER as upsAdvBatteryCurrentTableIndex  
  INTEGER as upsAdvBatteryCurrentIndex  
  INTEGER as upsAdvBatteryCurrentPolarity  
  INTEGER as upsAdvBatteryFrameCurrent  

UPSHighPrecBatteryActualVoltageEntry  
SEQUENCE    
  INTEGER as upsHighPrecBatteryActualVoltageTableIndex  
  INTEGER as upsHighPrecBatteryActualVoltagePolarity  
  INTEGER as upsHighPrecBatteryVoltage  

UPSHighPrecTotalDCCurrentEntry  
SEQUENCE    
  INTEGER as upsHighPrecTotalDCCurrentTableIndex  
  INTEGER as upsHighPrecTotalDCCurrentPolarity  
  INTEGER as upsHighPrecTotalDCFrameCurrent  

UPSHighPrecBatteryCurrentEntry  
SEQUENCE    
  INTEGER as upsHighPrecBatteryCurrentTableIndex  
  INTEGER as upsHighPrecBatteryCurrentIndex  
  INTEGER as upsHighPrecBatteryCurrentPolarity  
  INTEGER as upsHighPrecBatteryFrameCurrent  

UpsAdvInputStatisticsEntry  
SEQUENCE    
  INTEGER as upsAdvInputStatisticsIndex  
  INTEGER as upsAdvInputApparentPower  
  INTEGER as upsAdvInputVoltageTHD  
  INTEGER as upsAdvInputBypassVoltageTHD  
  INTEGER as upsAdvInputPeakCurrent  
  INTEGER as upsAdvInputBypassPeakCurrent  

UpsAdvOutputStatisticsEntry  
SEQUENCE    
  INTEGER as upsAdvOutputStatisticsIndex  
  INTEGER as upsAdvOutputPeakCurrent  
  INTEGER as upsAdvOutputCurrentTHD  
  INTEGER as upsAdvOutputCrestFactor  

UpsBasicConfigDeviceEntry  
SEQUENCE    
  INTEGER as deviceIndex  
  DisplayString as deviceName  
  INTEGER as vaRating  
  INTEGER as acceptThisDevice  

UpsAdvConfigDipSwitchEntry  
SEQUENCE    
  INTEGER as dipSwitchIndex  
  INTEGER as dipSwitchStatus  

UpsAdvConfigAllowedSetEntry  
SEQUENCE    
  INTEGER as apcUpsConfigFieldIndex  
  OBJECT IDENTIFIER as apcUpsConfigFieldOID  
  DisplayString as apcUpsConfigFieldValueRange  

UpsSCGStatusEntry  
SEQUENCE    
  INTEGER as upsSCGStatusTableIndex  
  IpAddress as upsSCGMemberIP  
  INTEGER as upsSCGACInputStatus  
  INTEGER as upsSCGACOutputStatus  

MUpsContactEntry  
SEQUENCE    
  INTEGER as contactNumber  
  INTEGER as normalState  
  DisplayString as description  
  INTEGER as monitoringStatus  
  INTEGER as currentStatus  

UpsPhaseInputEntry  
SEQUENCE    
  INTEGER as upsPhaseInputTableIndex  
  INTEGER as upsPhaseNumInputPhases  
  INTEGER as upsPhaseInputVoltageOrientation  
  INTEGER as upsPhaseInputFrequency  
  INTEGER as upsPhaseInputType  
  DisplayString as upsPhaseInputName  

UpsPhaseInputPhaseEntry  
SEQUENCE    
  INTEGER as upsPhaseInputPhaseTableIndex  
  INTEGER as upsPhaseInputPhaseIndex  
  INTEGER as upsPhaseInputVoltage  
  INTEGER as upsPhaseInputMaxVoltage  
  INTEGER as upsPhaseInputMinVoltage  
  INTEGER as upsPhaseInputCurrent  
  INTEGER as upsPhaseInputMaxCurrent  
  INTEGER as upsPhaseInputMinCurrent  
  INTEGER as upsPhaseInputPower  
  INTEGER as upsPhaseInputMaxPower  
  INTEGER as upsPhaseInputMinPower  

UpsPhaseOutputEntry  
SEQUENCE    
  INTEGER as upsPhaseOutputTableIndex  
  INTEGER as upsPhaseNumOutputPhases  
  INTEGER as upsPhaseOutputVoltageOrientation  
  INTEGER as upsPhaseOutputFrequency  

UpsPhaseOutputPhaseEntry  
SEQUENCE    
  INTEGER as upsPhaseOutputPhaseTableIndex  
  INTEGER as upsPhaseOutputPhaseIndex  
  INTEGER as upsPhaseOutputVoltage  
  INTEGER as upsPhaseOutputCurrent  
  INTEGER as upsPhaseOutputMaxCurrent  
  INTEGER as upsPhaseOutputMinCurrent  
  INTEGER as upsPhaseOutputLoad  
  INTEGER as upsPhaseOutputMaxLoad  
  INTEGER as upsPhaseOutputMinLoad  
  INTEGER as upsPhaseOutputPercentLoad  
  INTEGER as upsPhaseOutputMaxPercentLoad  
  INTEGER as upsPhaseOutputMinPercentLoad  
  INTEGER as upsPhaseOutputPower  
  INTEGER as upsPhaseOutputMaxPower  
  INTEGER as upsPhaseOutputMinPower  
  INTEGER as upsPhaseOutputPercentPower  
  INTEGER as upsPhaseOutputMaxPercentPower  
  INTEGER as upsPhaseOutputMinPercentPower  
  INTEGER as upsPhaseOutputPowerFactor  

UpsOutletGroupStatusEntry  
SEQUENCE    
  INTEGER as upsOutletGroupStatusIndex  
  DisplayString as upsOutletGroupStatusName  
  INTEGER as upsOutletGroupStatusGroupState  
  INTEGER as upsOutletGroupStatusCommandPending  
  INTEGER as upsOutletGroupStatusOutletType  

UpsOutletGroupConfigEntry  
SEQUENCE    
  INTEGER as upsOutletGroupConfigIndex  
  DisplayString as upsOutletGroupConfigName  
  INTEGER as upsOutletGroupConfigPowerOnDelay  
  INTEGER as upsOutletGroupConfigPowerOffDelay  
  INTEGER as upsOutletGroupConfigRebootDuration  
  INTEGER as upsOutletGroupConfigMinReturnRuntime  
  INTEGER as upsOutletGroupConfigOutletType  
  INTEGER as upsOutletGroupConfigLoadShedControlSkipOffDelay  
  INTEGER as upsOutletGroupConfigLoadShedControlAutoRestart  
  INTEGER as upsOutletGroupConfigLoadShedControlTimeOnBattery  
  INTEGER as upsOutletGroupConfigLoadShedControlRuntimeRemaining  
  INTEGER as upsOutletGroupConfigLoadShedControlInOverload  
  INTEGER as upsOutletGroupConfigLoadShedTimeOnBattery  
  INTEGER as upsOutletGroupConfigLoadShedRuntimeRemaining  

UpsOutletGroupControlEntry  
SEQUENCE    
  INTEGER as upsOutletGroupControlIndex  
  DisplayString as upsOutletGroupControlName  
  INTEGER as upsOutletGroupControlCommand  
  INTEGER as upsOutletGroupControlOutletType  

UpsDiagIMEntry  
SEQUENCE    
  INTEGER as upsDiagIMIndex  
  INTEGER as upsDiagIMType  
  INTEGER as upsDiagIMStatus  
  DisplayString as upsDiagIMFirmwareRev  
  DisplayString as upsDiagIMSlaveFirmwareRev  
  DisplayString as upsDiagIMHardwareRev  
  DisplayString as upsDiagIMSerialNum  
  DisplayString as upsDiagIMManufactureDate  

UpsDiagPMEntry  
SEQUENCE    
  INTEGER as upsDiagPMIndex  
  INTEGER as upsDiagPMStatus  
  DisplayString as upsDiagPMFirmwareRev  
  DisplayString as upsDiagPMHardwareRev  
  DisplayString as upsDiagPMSerialNum  
  DisplayString as upsDiagPMManufactureDate  

UpsDiagBatteryEntry  
SEQUENCE    
  INTEGER as upsDiagBatteryFrameIndex  
  INTEGER as upsDiagBatteryIndex  
  INTEGER as upsDiagBatteryStatus  
  DisplayString as upsDiagBatterySerialNumber  
  DisplayString as upsDiagBatteryFirmwareRev  
  DisplayString as upsDiagBatteryManufactureDate  
  DisplayString as upsDiagBatteryType  

UpsDiagSubSysFrameEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysFrameIndex  
  INTEGER as upsDiagSubSysFrameType  
  DisplayString as upsDiagSubSysFrameFirmwareRev  
  DisplayString as upsDiagSubSysFrameHardwareRev  
  DisplayString as upsDiagSubSysFrameSerialNum  
  DisplayString as upsDiagSubSysFrameManufactureDate  

UpsDiagSubSysIntBypSwitchEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysIntBypSwitchFrameIndex  
  INTEGER as upsDiagSubSysIntBypSwitchIndex  
  INTEGER as upsDiagSubSysIntBypSwitchStatus  
  DisplayString as upsDiagSubSysIntBypSwitchFirmwareRev  
  DisplayString as upsDiagSubSysIntBypSwitchHardwareRev  
  DisplayString as upsDiagSubSysIntBypSwitchSerialNum  
  DisplayString as upsDiagSubSysIntBypSwitchManufactureDate  

UpsDiagSubSysBattMonitorEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysBattMonitorFrameIndex  
  INTEGER as upsDiagSubSysBattMonitorIndex  
  INTEGER as upsDiagSubSysBattMonitorStatus  
  DisplayString as upsDiagSubSysBattMonitorFirmwareRev  
  DisplayString as upsDiagSubSysBattMonitorHardwareRev  
  DisplayString as upsDiagSubSysBattMonitorSerialNum  
  DisplayString as upsDiagSubSysBattMonitorManufactureDate  

UpsDiagSubSysExternalSwitchGearEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysExternalSwitchGearFrameIndex  
  INTEGER as upsDiagSubSysExternalSwitchGearIndex  
  INTEGER as upsDiagSubSysExternalSwitchGearStatus  
  DisplayString as upsDiagSubSysExternalSwitchGearFirmwareRev  
  DisplayString as upsDiagSubSysExternalSwitchGearHardwareRev  
  DisplayString as upsDiagSubSysExternalSwitchGearSerialNum  
  DisplayString as upsDiagSubSysExternalSwitchGearManufactureDate  

UpsDiagSubSysDisplayInterfaceCardEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysDisplayInterfaceCardFrameIndex  
  INTEGER as upsDiagSubSysDisplayInterfaceCardIndex  
  INTEGER as upsDiagSubSysDisplayInterfaceCardStatus  

UpsDiagSubSysDCCircuitBreakerEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysDCCircuitBreakerFrameIndex  
  INTEGER as upsDiagSubSysDCCircuitBreakerIndex  
  INTEGER as upsDiagSubSysDCCircuitBreakerStatus  

UpsDiagSubSysSystemPowerSupplyEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysSystemPowerSupplyFrameIndex  
  INTEGER as upsDiagSubSysSystemPowerSupplyIndex  
  INTEGER as upsDiagSubSysSystemPowerSupplyStatus  
  DisplayString as upsDiagSubSysSystemPowerSupplyFirmwareRev  
  DisplayString as upsDiagSubSysSystemPowerSupplyHardwareRev  
  DisplayString as upsDiagSubSysSystemPowerSupplySerialNum  
  DisplayString as upsDiagSubSysSystemPowerSupplyManufactureDate  

UpsDiagSubSysXRCommunicationCardEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysXRCommunicationCardFrameIndex  
  INTEGER as upsDiagSubSysXRCommunicationCardIndex  
  INTEGER as upsDiagSubSysXRCommunicationCardStatus  
  DisplayString as upsDiagSubSysXRCommunicationCardFirmwareRev  
  DisplayString as upsDiagSubSysXRCommunicationCardSerialNum  

UpsDiagSubSysExternalPowerFrameBoardEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysExternalPowerFrameBoardFrameIndex  
  INTEGER as upsDiagSubSysExternalPowerFrameBoardIndex  
  INTEGER as upsDiagSubSysExternalPowerFrameBoardStatus  

UpsDiagSubSysChargerEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysChargerFrameIndex  
  INTEGER as upsDiagSubSysChargerIndex  
  INTEGER as upsDiagSubSysChargerStatus  

UpsDiagSubSysInverterEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysInverterFrameIndex  
  INTEGER as upsDiagSubSysInverterIndex  
  INTEGER as upsDiagSubSysInverterStatus  
  DisplayString as upsDiagSubSysInverterFirmwareRev  
  DisplayString as upsDiagSubSysInverterHardwareRev  
  DisplayString as upsDiagSubSysInverterSerialNum  
  DisplayString as upsDiagSubSysInverterManufactureDate  

UpsDiagSubSysPowerFactorCorrectionEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysPowerFactorCorrectionFrameIndex  
  INTEGER as upsDiagSubSysPowerFactorCorrectionIndex  
  INTEGER as upsDiagSubSysPowerFactorCorrectionStatus  
  DisplayString as upsDiagSubSysPowerFactorCorrectionFirmwareRev  
  DisplayString as upsDiagSubSysPowerFactorCorrectionHardwareRev  
  DisplayString as upsDiagSubSysPowerFactorCorrectionSerialNum  
  DisplayString as upsDiagSubSysPowerFactorCorrectionManufactureDate  

UpsDiagSubSysNetworkComCardEntry  
SEQUENCE    
  INTEGER as upsDiagSubSysNetworkComCardIndex  
  DisplayString as upsDiagSubSysNetworkComCardModelNumber  
  DisplayString as upsDiagSubSysNetworkComCardSerialNumber  
  DisplayString as upsDiagSubSysNetworkComCardDateOfManufacture  
  DisplayString as upsDiagSubSysNetworkComCardHardwareRev  
  DisplayString as upsDiagSubSysNetworkComCardFirmwareAppRev  
  DisplayString as upsDiagSubSysNetworkComCardFirmwareAppOSRev  

UpsDiagSwitchGearBreakerEntry  
SEQUENCE    
  INTEGER as switchgearBreakerIndex  
  INTEGER as switchgearBreakerPresent  
  DisplayString as switchgearBreakerName  

UpsDiagSubFeedBreakerEntry  
SEQUENCE    
  INTEGER as subfeedBreakerIndex  
  INTEGER as subfeedBreakerPresent  
  INTEGER as subfeedBreakerRating  
  INTEGER as subfeedBreakerUpperAcceptPowerWarning  
  INTEGER as subfeedBreakerUpperAcceptPowerCritical  

UpsParallelInputPhaseEntry  
SEQUENCE    
  INTEGER as upsParallelInputPhaseTableIndex  
  INTEGER as upsParallelInputPhaseIndex  
  INTEGER as upsParallelInputCurrent  
  INTEGER as upsParallelInputActivePower  
  INTEGER as upsParallelInputApparentPower  
  INTEGER as upsParallelInputVoltage  
  INTEGER as upsParallelInputMaxVoltage  
  INTEGER as upsParallelInputMaxCurrent  
  INTEGER as upsParallelInputTotalActivePower  
  INTEGER as upsParallelInputTotalApparentPower  

UpsParallelOutputPhaseEntry  
SEQUENCE    
  INTEGER as upsParallelOutputPhaseTableIndex  
  INTEGER as upsParallelOutputPhaseIndex  
  INTEGER as upsParallelOutputCurrent  
  INTEGER as upsParallelOutputLoad  
  INTEGER as upsParallelOutputPercentLoad  
  INTEGER as upsParallelOutputPower  

UpsParallelOutputApparentPowerEntry  
SEQUENCE    
  INTEGER as upsParallelOutputApparentPowerTableIndex  
  INTEGER as upsParallelOutputApparentPower  

UpsParallelDiagSubSysBreakerEntry  
SEQUENCE    
  INTEGER as upsParallelDiagSubSysBreakerFrameIndex  
  INTEGER as upsParallelDiagSubSysBreakerIndex  
  INTEGER as upsParallelDiagSubSysBreakerStatus  
  DisplayString as upsParallelDiagSubSysBreakerName  

UpsParallelOutputActivePowerEntry  
SEQUENCE    
  INTEGER as upsParallelOutputActivePowerTableIndex  
  INTEGER as upsParallelOutputActivePower  

UpsBatteryFrameLayoutEntry  
SEQUENCE    
  INTEGER as batteryFrameIndex  
  INTEGER as batteryFramePositionID  

UpsSideCarFrameLayoutEntry  
SEQUENCE    
  INTEGER as sideCarFrameIndex  
  INTEGER as sideCarFramePositionID  

UpsPowerFrameLayoutEntry  
SEQUENCE    
  INTEGER as powerFrameIndex  
  INTEGER as powerFramePositionID  

UpsIntegratedATSSourceEntry  
SEQUENCE    
  INTEGER as upsIntegratedATSSourceIndex  
  DisplayString as upsIntegratedATSSourceName  
  INTEGER as upsIntegratedATSSourceStatus  
  INTEGER as upsIntegratedATSLineFailDelay  
  INTEGER as upsIntegratedATSLineStabilityDelay  

SPDUOutletControlEntry  
SEQUENCE    
  INTEGER as sPDUOutletControlIndex  
  INTEGER as sPDUOutletPending  
  INTEGER as sPDUOutletCtl  
  DisplayString as sPDUOutletCtlName  

SPDUOutletConfigEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigIndex  
  INTEGER as sPDUOutletPowerOnTime  
  DisplayString as sPDUOutletName  
  INTEGER as sPDUOutletPowerOffTime  
  INTEGER as sPDUOutletRebootDuration  

SPDUIdentVMEntry  
SEQUENCE    
  INTEGER as sPDUIdentVMIndex  
  DisplayString as sPDUIdentNameVM  
  DisplayString as sPDUIdentHardwareRevVM  
  DisplayString as sPDUIdentFirmwareRevVM  
  DisplayString as sPDUIdentDateOfManufactureVM  
  DisplayString as sPDUIdentModelNumberVM  
  DisplayString as sPDUIdentSerialNumberVM  

SPDUMasterControlVMEntry  
SEQUENCE    
  INTEGER as sPDUMasterControlVMIndex  
  DisplayString as sPDUMasterControlVMName  
  INTEGER as sPDUMasterControlVMCommand  

SPDUMasterConfigVMEntry  
SEQUENCE    
  INTEGER as sPDUMasterConfigVMIndex  
  DisplayString as sPDUMasterConfigVMName  
  INTEGER as sPDUMasterConfigVMColdstartDelay  
  INTEGER as sPDUMasterConfigVMAudioAlarmActivated  
  INTEGER as sPDUMasterConfigVMHighLoadWarningThreshold  
  INTEGER as sPDUMasterConfigVMLowLoadWarningThreshold  
  INTEGER as sPDUMasterConfigVMOverloadRestriction  

SPDUMasterStatusVMEntry  
SEQUENCE    
  INTEGER as sPDUMasterStatusVMIndex  
  DisplayString as sPDUMasterStatusVMName  
  INTEGER as sPDUMasterStatusVMCommandPending  
  INTEGER as sPDUMasterStatusVMOverloadCondition  
  INTEGER as sPDUMasterStatusVMLowLoadCondition  
  INTEGER as sPDUMasterStatusVMCurrentLoad  
  INTEGER as sPDUMasterStatusVMMaxLoad  
  INTEGER as sPDUMasterStatusVMOutletCount  
  INTEGER as sPDUMasterStatusVMRebootDuration  

SPDUOutletControlVMEntry  
SEQUENCE    
  INTEGER as sPDUOutletControlVMIndex  
  DisplayString as sPDUOutletControlVMName  
  INTEGER as sPDUOutletControlVMOutletIndex  
  DisplayString as sPDUOutletControlVMOutletName  
  INTEGER as sPDUOutletControlVMOutletCommand  

SPDUOutletConfigVMEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigVMIndex  
  DisplayString as sPDUOutletConfigVMName  
  INTEGER as sPDUOutletConfigVMOutletIndex  
  DisplayString as sPDUOutletConfigVMOutletName  
  INTEGER as sPDUOutletConfigVMPowerOnTime  
  INTEGER as sPDUOutletConfigVMPowerOffTime  
  INTEGER as sPDUOutletConfigVMRebootDuration  

SPDUOutletStatusVMEntry  
SEQUENCE    
  INTEGER as sPDUOutletStatusVMIndex  
  DisplayString as sPDUOutletStatusVMName  
  INTEGER as sPDUOutletStatusVMOutletIndex  
  DisplayString as sPDUOutletStatusVMOutletName  
  INTEGER as sPDUOutletStatusVMOutletState  
  INTEGER as sPDUOutletStatusVMCommandPending  

SPDUIdentMSPEntry  
SEQUENCE    
  INTEGER as sPDUIdentMSPIndex  
  DisplayString as sPDUIdentNameMSP  
  DisplayString as sPDUIdentHardwareRevMSP  
  DisplayString as sPDUIdentFirmwareRevMSP  
  DisplayString as sPDUIdentDateOfManufactureMSP  
  DisplayString as sPDUIdentModelNumberMSP  
  DisplayString as sPDUIdentSerialNumberMSP  

SPDUMasterControlMSPEntry  
SEQUENCE    
  INTEGER as sPDUMasterControlMSPIndex  
  DisplayString as sPDUMasterControlMSPName  
  INTEGER as sPDUMasterControlMSPCommand  

SPDUMasterConfigMSPEntry  
SEQUENCE    
  INTEGER as sPDUMasterConfigMSPIndex  
  DisplayString as sPDUMasterConfigMSPName  
  INTEGER as sPDUMasterConfigMSPPowerOnTimeDelay  
  INTEGER as sPDUMasterConfigMSPManualButton  

SPDUMasterStatusMSPEntry  
SEQUENCE    
  INTEGER as sPDUMasterStatusMSPIndex  
  DisplayString as sPDUMasterStatusMSPName  
  INTEGER as sPDUMasterStatusMSPOutletCount  

SPDUOutletControlMSPEntry  
SEQUENCE    
  INTEGER as sPDUOutletControlMSPIndex  
  DisplayString as sPDUOutletControlMSPName  
  INTEGER as sPDUOutletControlMSPOutletIndex  
  DisplayString as sPDUOutletControlMSPOutletName  
  INTEGER as sPDUOutletControlMSPOutletCommand  

SPDUOutletConfigMSPallEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigMSPallIndex  
  DisplayString as sPDUOutletConfigMSPallName  
  INTEGER as sPDUOutletConfigMSPallOutletIndex  
  DisplayString as sPDUOutletConfigMSPallOutletName  
  INTEGER as sPDUOutletConfigMSPallOutletCtrlMode  

SPDUOutletConfigMSPgsEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigMSPgsIndex  
  DisplayString as sPDUOutletConfigMSPgsName  
  INTEGER as sPDUOutletConfigMSPgsOutletIndex  
  DisplayString as sPDUOutletConfigMSPgsOutletName  
  INTEGER as sPDUOutletConfigMSPgsOutletCtrlMode  
  INTEGER as sPDUOutletConfigMSPgsDeviceConfirm  
  INTEGER as sPDUOutletConfigMSPgsLowBattWarning  
  INTEGER as sPDUOutletConfigMSPgsLowBattMult  
  INTEGER as sPDUOutletConfigMSPgsRestartDelay  
  INTEGER as sPDUOutletConfigMSPgsPowerOnDelay  
  INTEGER as sPDUOutletConfigMSPgsPowerOffDelay  
  INTEGER as sPDUOutletConfigMSPgsBattCapThresh  
  INTEGER as sPDUOutletConfigMSPgsRebootDuration  

SPDUOutletConfigMSPannunEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigMSPannunIndex  
  DisplayString as sPDUOutletConfigMSPannunName  
  INTEGER as sPDUOutletConfigMSPannunOutletIndex  
  DisplayString as sPDUOutletConfigMSPannunOutletName  
  INTEGER as sPDUOutletConfigMSPannunOutletCtrlMode  
  INTEGER as sPDUOutletConfigMSPannunInitialState  
  INTEGER as sPDUOutletConfigMSPannunAlarmActionDly  

SPDUOutletConfigMSPmupsEntry  
SEQUENCE    
  INTEGER as sPDUOutletConfigMSPmupsIndex  
  DisplayString as sPDUOutletConfigMSPmupsName  
  INTEGER as sPDUOutletConfigMSPmupsOutletIndex  
  DisplayString as sPDUOutletConfigMSPmupsOutletName  
  INTEGER as sPDUOutletConfigMSPmupsZone1  
  INTEGER as sPDUOutletConfigMSPmupsZone2  
  INTEGER as sPDUOutletConfigMSPmupsZone3  
  INTEGER as sPDUOutletConfigMSPmupsZone4  
  INTEGER as sPDUOutletConfigMSPmupsP1LowHum  
  INTEGER as sPDUOutletConfigMSPmupsP1HiHum  
  INTEGER as sPDUOutletConfigMSPmupsP1LowTemp  
  INTEGER as sPDUOutletConfigMSPmupsP1HiTemp  
  INTEGER as sPDUOutletConfigMSPmupsP2LowHum  
  INTEGER as sPDUOutletConfigMSPmupsP2HiHum  
  INTEGER as sPDUOutletConfigMSPmupsP2LowTemp  
  INTEGER as sPDUOutletConfigMSPmupsP2HiTemp  

SPDUOutletStatusMSPEntry  
SEQUENCE    
  INTEGER as sPDUOutletStatusMSPIndex  
  DisplayString as sPDUOutletStatusMSPName  
  INTEGER as sPDUOutletStatusMSPOutletIndex  
  DisplayString as sPDUOutletStatusMSPOutletName  
  INTEGER as sPDUOutletStatusMSPOutletState  
  INTEGER as sPDUOutletStatusMSPCommandPending  
  INTEGER as sPDUOutletStatusMSPOutletCtrlMode  

RPDULoadDevBankEntry  
SEQUENCE    
  INTEGER as rPDULoadDevBankIndex  
  INTEGER as rPDULoadDevBankNumber  
  INTEGER as rPDULoadDevBankMaxLoad  

RPDULoadDevMaxOutletEntry  
SEQUENCE    
  INTEGER as rPDULoadDevOutletIndex  
  INTEGER as rPDULoadDevOutletNumber  
  INTEGER as rPDULoadDevMaxOutletLoad  

RPDULoadPhaseConfigEntry  
SEQUENCE    
  INTEGER as rPDULoadPhaseConfigIndex  
  INTEGER as rPDULoadPhaseConfigLowLoadThreshold  
  INTEGER as rPDULoadPhaseConfigNearOverloadThreshold  
  INTEGER as rPDULoadPhaseConfigOverloadThreshold  
  INTEGER as rPDULoadPhaseConfigAlarm  

RPDULoadStatusEntry  
SEQUENCE    
  INTEGER as rPDULoadStatusIndex  
  Gauge as rPDULoadStatusLoad  
  INTEGER as rPDULoadStatusLoadState  
  INTEGER as rPDULoadStatusPhaseNumber  
  INTEGER as rPDULoadStatusBankNumber  

RPDULoadBankConfigEntry  
SEQUENCE    
  INTEGER as rPDULoadBankConfigIndex  
  INTEGER as rPDULoadBankConfigLowLoadThreshold  
  INTEGER as rPDULoadBankConfigNearOverloadThreshold  
  INTEGER as rPDULoadBankConfigOverloadThreshold  
  INTEGER as rPDULoadBankConfigAlarm  

RPDUOutletPhaseEntry  
SEQUENCE    
  INTEGER as rPDUOutletPhaseIndex  
  INTEGER as rPDUOutletPhaseOverloadRestriction  

RPDUOutletControlEntry  
SEQUENCE    
  INTEGER as rPDUOutletControlIndex  
  DisplayString as rPDUOutletControlOutletName  
  INTEGER as rPDUOutletControlOutletPhase  
  INTEGER as rPDUOutletControlOutletCommand  
  INTEGER as rPDUOutletControlOutletBank  

RPDUOutletConfigEntry  
SEQUENCE    
  INTEGER as rPDUOutletConfigIndex  
  DisplayString as rPDUOutletConfigOutletName  
  INTEGER as rPDUOutletConfigOutletPhase  
  INTEGER as rPDUOutletConfigPowerOnTime  
  INTEGER as rPDUOutletConfigPowerOffTime  
  INTEGER as rPDUOutletConfigRebootDuration  
  INTEGER as rPDUOutletConfigOutletBank  

RPDUOutletConfigMonitoredEntry  
SEQUENCE    
  INTEGER as rPDUOutletConfigMonitoredIndex  
  DisplayString as rPDUOutletConfigMonitoredName  
  INTEGER as rPDUOutletConfigMonitoredNumber  
  INTEGER as rPDUOutletConfigMonitoredLowLoadThreshold  
  INTEGER as rPDUOutletConfigMonitoredNearOverloadThreshold  
  INTEGER as rPDUOutletConfigMonitoredOverloadThreshold  

RPDUOutletStatusEntry  
SEQUENCE    
  INTEGER as rPDUOutletStatusIndex  
  DisplayString as rPDUOutletStatusOutletName  
  INTEGER as rPDUOutletStatusOutletPhase  
  INTEGER as rPDUOutletStatusOutletState  
  INTEGER as rPDUOutletStatusCommandPending  
  INTEGER as rPDUOutletStatusOutletBank  
  Gauge as rPDUOutletStatusLoad  

RPDUOutletBankEntry  
SEQUENCE    
  INTEGER as rPDUOutletBankIndex  
  INTEGER as rPDUOutletBankOverloadRestriction  

RPDUStatusBankEntry  
SEQUENCE    
  INTEGER as rPDUStatusBankIndex  
  INTEGER as rPDUStatusBankNumber  
  INTEGER as rPDUStatusBankState  

RPDUStatusPhaseEntry  
SEQUENCE    
  INTEGER as rPDUStatusPhaseIndex  
  INTEGER as rPDUStatusPhaseNumber  
  INTEGER as rPDUStatusPhaseState  

RPDUStatusOutletEntry  
SEQUENCE    
  INTEGER as rPDUStatusOutletIndex  
  INTEGER as rPDUStatusOutletNumber  
  INTEGER as rPDUStatusOutletState  

Rpdu2OutletPhaseLayoutType  
INTEGER seqPhase1ToNeutral(1), seqPhase2ToNeutral(2), seqPhase3ToNeutral(3), seqPhase1ToPhase2(4), seqPhase2ToPhase3(5), seqPhase3ToPhase1(6)    

RPDU2IdentEntry  
SEQUENCE    
  INTEGER as rPDU2IdentIndex  
  INTEGER as rPDU2IdentModule  
  DisplayString as rPDU2IdentName  
  DisplayString as rPDU2IdentLocation  
  DisplayString as rPDU2IdentHardwareRev  
  DisplayString as rPDU2IdentFirmwareRev  
  DisplayString as rPDU2IdentDateOfManufacture  
  DisplayString as rPDU2IdentModelNumber  
  DisplayString as rPDU2IdentSerialNumber  
  DisplayString as rPDU2IdentContact  

RPDU2DeviceConfigEntry  
SEQUENCE    
  INTEGER as rPDU2DeviceConfigIndex  
  INTEGER as rPDU2DeviceConfigModule  
  DisplayString as rPDU2DeviceConfigName  
  DisplayString as rPDU2DeviceConfigLocation  
  INTEGER as rPDU2DeviceConfigDisplayOrientation  
  INTEGER as rPDU2DeviceConfigColdstartDelay  
  INTEGER as rPDU2DeviceConfigLowLoadPowerThreshold  
  INTEGER as rPDU2DeviceConfigNearOverloadPowerThreshold  
  INTEGER as rPDU2DeviceConfigOverloadPowerThreshold  
  INTEGER as rPDU2DeviceConfigDevicePeakPowerReset  
  INTEGER as rPDU2DeviceConfigDeviceEnergyReset  
  INTEGER as rPDU2DeviceConfigOutletsEnergyReset  

RPDU2DevicePropertiesEntry  
SEQUENCE    
  INTEGER as rPDU2DevicePropertiesIndex  
  INTEGER as rPDU2DevicePropertiesModule  
  DisplayString as rPDU2DevicePropertiesName  
  INTEGER as rPDU2DevicePropertiesNumOutlets  
  INTEGER as rPDU2DevicePropertiesNumSwitchedOutlets  
  INTEGER as rPDU2DevicePropertiesNumMeteredOutlets  
  INTEGER as rPDU2DevicePropertiesNumPhases  
  INTEGER as rPDU2DevicePropertiesNumMeteredBanks  
  INTEGER as rPDU2DevicePropertiesMaxCurrentRating  
  INTEGER as rPDU2DevicePropertiesOrientation  
  INTEGER as rPDU2DevicePropertiesOutletLayout  
  INTEGER as rPDU2DevicePropertiesMaxPhaseCurrentRating  

RPDU2DeviceStatusEntry  
SEQUENCE    
  INTEGER as rPDU2DeviceStatusIndex  
  INTEGER as rPDU2DeviceStatusModule  
  DisplayString as rPDU2DeviceStatusName  
  INTEGER as rPDU2DeviceStatusLoadState  
  INTEGER as rPDU2DeviceStatusPower  
  INTEGER as rPDU2DeviceStatusPeakPower  
  DisplayString as rPDU2DeviceStatusPeakPowerTimestamp  
  DisplayString as rPDU2DeviceStatusPeakPowerStartTime  
  INTEGER as rPDU2DeviceStatusEnergy  
  DisplayString as rPDU2DeviceStatusEnergyStartTime  
  INTEGER as rPDU2DeviceStatusCommandPending  
  INTEGER as rPDU2DeviceStatusPowerSupplyAlarm  
  INTEGER as rPDU2DeviceStatusPowerSupply1Status  
  INTEGER as rPDU2DeviceStatusPowerSupply2Status  
  DisplayString as rPDU2DeviceStatusOutletsEnergyStartTime  

RPDU2DeviceControlEntry  
SEQUENCE    
  INTEGER as rPDU2DeviceControlIndex  
  INTEGER as rPDU2DeviceControlModule  
  DisplayString as rPDU2DeviceControlName  
  INTEGER as rPDU2DeviceControlCommand  

RPDU2PhaseConfigEntry  
SEQUENCE    
  INTEGER as rPDU2PhaseConfigIndex  
  INTEGER as rPDU2PhaseConfigModule  
  INTEGER as rPDU2PhaseConfigNumber  
  INTEGER as rPDU2PhaseConfigOverloadRestriction  
  INTEGER as rPDU2PhaseConfigLowLoadCurrentThreshold  
  INTEGER as rPDU2PhaseConfigNearOverloadCurrentThreshold  
  INTEGER as rPDU2PhaseConfigOverloadCurrentThreshold  

RPDU2PhasePropertiesEntry  
SEQUENCE    
  INTEGER as rPDU2PhasePropertiesIndex  
  INTEGER as rPDU2PhasePropertiesModule  
  INTEGER as rPDU2PhasePropertiesNumber  

RPDU2PhaseStatusEntry  
SEQUENCE    
  INTEGER as rPDU2PhaseStatusIndex  
  INTEGER as rPDU2PhaseStatusModule  
  INTEGER as rPDU2PhaseStatusNumber  
  INTEGER as rPDU2PhaseStatusLoadState  
  INTEGER as rPDU2PhaseStatusCurrent  
  INTEGER as rPDU2PhaseStatusVoltage  
  INTEGER as rPDU2PhaseStatusPower  

RPDU2BankConfigEntry  
SEQUENCE    
  INTEGER as rPDU2BankConfigIndex  
  INTEGER as rPDU2BankConfigModule  
  INTEGER as rPDU2BankConfigNumber  
  INTEGER as rPDU2BankConfigOverloadRestriction  
  INTEGER as rPDU2BankConfigLowLoadCurrentThreshold  
  INTEGER as rPDU2BankConfigNearOverloadCurrentThreshold  
  INTEGER as rPDU2BankConfigOverloadCurrentThreshold  

RPDU2BankPropertiesEntry  
SEQUENCE    
  INTEGER as rPDU2BankPropertiesIndex  
  INTEGER as rPDU2BankPropertiesModule  
  INTEGER as rPDU2BankPropertiesNumber  
  Rpdu2OutletPhaseLayoutType as rPDU2BankPropertiesPhaseLayout  

RPDU2BankStatusEntry  
SEQUENCE    
  INTEGER as rPDU2BankStatusIndex  
  INTEGER as rPDU2BankStatusModule  
  INTEGER as rPDU2BankStatusNumber  
  INTEGER as rPDU2BankStatusLoadState  
  INTEGER as rPDU2BankStatusCurrent  

RPDU2OutletSwitchedConfigEntry  
SEQUENCE    
  INTEGER as rPDU2OutletSwitchedConfigIndex  
  INTEGER as rPDU2OutletSwitchedConfigModule  
  DisplayString as rPDU2OutletSwitchedConfigName  
  INTEGER as rPDU2OutletSwitchedConfigNumber  
  INTEGER as rPDU2OutletSwitchedConfigPowerOnTime  
  INTEGER as rPDU2OutletSwitchedConfigPowerOffTime  
  INTEGER as rPDU2OutletSwitchedConfigRebootDuration  

RPDU2OutletSwitchedPropertiesEntry  
SEQUENCE    
  INTEGER as rPDU2OutletSwitchedPropertiesIndex  
  INTEGER as rPDU2OutletSwitchedPropertiesModule  
  DisplayString as rPDU2OutletSwitchedPropertiesName  
  INTEGER as rPDU2OutletSwitchedPropertiesNumber  
  Rpdu2OutletPhaseLayoutType as rPDU2OutletSwitchedPropertiesPhaseLayout  
  INTEGER as rPDU2OutletSwitchedPropertiesBank  

RPDU2OutletSwitchedStatusEntry  
SEQUENCE    
  INTEGER as rPDU2OutletSwitchedStatusIndex  
  INTEGER as rPDU2OutletSwitchedStatusModule  
  DisplayString as rPDU2OutletSwitchedStatusName  
  INTEGER as rPDU2OutletSwitchedStatusNumber  
  INTEGER as rPDU2OutletSwitchedStatusState  
  INTEGER as rPDU2OutletSwitchedStatusCommandPending  

RPDU2OutletSwitchedControlEntry  
SEQUENCE    
  INTEGER as rPDU2OutletSwitchedControlIndex  
  INTEGER as rPDU2OutletSwitchedControlModule  
  DisplayString as rPDU2OutletSwitchedControlName  
  INTEGER as rPDU2OutletSwitchedControlNumber  
  INTEGER as rPDU2OutletSwitchedControlCommand  

RPDU2OutletMeteredConfigEntry  
SEQUENCE    
  INTEGER as rPDU2OutletMeteredConfigIndex  
  INTEGER as rPDU2OutletMeteredConfigModule  
  DisplayString as rPDU2OutletMeteredConfigName  
  INTEGER as rPDU2OutletMeteredConfigNumber  
  INTEGER as rPDU2OutletMeteredConfigLowLoadCurrentThreshold  
  INTEGER as rPDU2OutletMeteredConfigNearOverloadCurrentThreshold  
  INTEGER as rPDU2OutletMeteredConfigOverloadCurrentThreshold  

RPDU2OutletMeteredPropertiesEntry  
SEQUENCE    
  INTEGER as rPDU2OutletMeteredPropertiesIndex  
  INTEGER as rPDU2OutletMeteredPropertiesModule  
  DisplayString as rPDU2OutletMeteredPropertiesName  
  INTEGER as rPDU2OutletMeteredPropertiesNumber  
  Rpdu2OutletPhaseLayoutType as rPDU2OutletMeteredPropertiesLayout  
  INTEGER as rPDU2OutletMeteredPropertiesPowerRating  
  INTEGER as rPDU2OutletMeteredPropertiesBank  

RPDU2OutletMeteredStatusEntry  
SEQUENCE    
  INTEGER as rPDU2OutletMeteredStatusIndex  
  INTEGER as rPDU2OutletMeteredStatusModule  
  DisplayString as rPDU2OutletMeteredStatusName  
  INTEGER as rPDU2OutletMeteredStatusNumber  
  INTEGER as rPDU2OutletMeteredStatusState  
  INTEGER as rPDU2OutletMeteredStatusCurrent  
  INTEGER as rPDU2OutletMeteredStatusPower  
  INTEGER as rPDU2OutletMeteredStatusPeakPower  
  DisplayString as rPDU2OutletMeteredStatusPeakPowerTimestamp  
  DisplayString as rPDU2OutletMeteredStatusPeakPowerStartTime  
  INTEGER as rPDU2OutletMeteredStatusEnergy  

RPDU2SensorTempHumidityConfigEntry  
SEQUENCE    
  INTEGER as rPDU2SensorTempHumidityConfigIndex  
  INTEGER as rPDU2SensorTempHumidityConfigModule  
  DisplayString as rPDU2SensorTempHumidityConfigName  
  INTEGER as rPDU2SensorTempHumidityConfigNumber  
  INTEGER as rPDU2SensorTempHumidityConfigTemperatureAlarmEnable  
  INTEGER as rPDU2SensorTempHumidityConfigHumidityAlarmEnable  
  INTEGER as rPDU2SensorTempHumidityConfigTempMaxThreshF  
  INTEGER as rPDU2SensorTempHumidityConfigTempHighThreshF  
  INTEGER as rPDU2SensorTempHumidityConfigTempHysteresisF  
  INTEGER as rPDU2SensorTempHumidityConfigTempMaxThreshC  
  INTEGER as rPDU2SensorTempHumidityConfigTempHighThreshC  
  INTEGER as rPDU2SensorTempHumidityConfigTempHysteresisC  
  INTEGER as rPDU2SensorTempHumidityConfigHumidityLowThresh  
  INTEGER as rPDU2SensorTempHumidityConfigHumidityMinThresh  
  INTEGER as rPDU2SensorTempHumidityConfigHumidityHysteresis  

RPDU2SensorTempHumidityStatusEntry  
SEQUENCE    
  INTEGER as rPDU2SensorTempHumidityStatusIndex  
  INTEGER as rPDU2SensorTempHumidityStatusModule  
  DisplayString as rPDU2SensorTempHumidityStatusName  
  INTEGER as rPDU2SensorTempHumidityStatusNumber  
  INTEGER as rPDU2SensorTempHumidityStatusType  
  INTEGER as rPDU2SensorTempHumidityStatusCommStatus  
  INTEGER as rPDU2SensorTempHumidityStatusTempF  
  INTEGER as rPDU2SensorTempHumidityStatusTempC  
  INTEGER as rPDU2SensorTempHumidityStatusTempStatus  
  INTEGER as rPDU2SensorTempHumidityStatusRelativeHumidity  
  INTEGER as rPDU2SensorTempHumidityStatusHumidityStatus  

Dm3IdentSysDescriptionEntry  
SEQUENCE    
  INTEGER as dm3IdentSysDescriptionIndex  
  DisplayString as dm3IdentSysDescriptionText  

Dm3ConfigSysDescriptionEntry  
SEQUENCE    
  INTEGER as dm3ConfigSysDescriptionIndex  
  DisplayString as dm3ConfigSysDescriptionText  

Dm3ConfigLVDEntry  
SEQUENCE    
  INTEGER as dm3ConfigLVDIndex  
  DisplayString as dm3ConfigLVDName  
  INTEGER as dm3ConfigLVDEnable  
  INTEGER as dm3ConfigLVDTripThresh  
  INTEGER as dm3ConfigLVDResetThresh  
  INTEGER as dm3ConfigLVDOpenAlarm  
  INTEGER as dm3ConfigLVDHWAlarm  

Dm3ConfigOutRlyEntry  
SEQUENCE    
  INTEGER as dm3ConfigOutRlyIndex  
  DisplayString as dm3ConfigOutRlyName  
  INTEGER as dm3ConfigOutRlyDelay  
  INTEGER as dm3ConfigOutRlyAlarm  

Dm3ConfigInRlyEntry  
SEQUENCE    
  INTEGER as dm3ConfigInRlyIndex  
  DisplayString as dm3ConfigInRlyName  
  INTEGER as dm3ConfigInRlyDelay  
  INTEGER as dm3ConfigInRlyAlarm  

Dm3ConfigBreakersEntry  
SEQUENCE    
  INTEGER as dm3ConfigBreakersIndex  
  DisplayString as dm3ConfigBreakersName  
  INTEGER as dm3ConfigBreakersAlarm  

Dm3ConfigFusesEntry  
SEQUENCE    
  INTEGER as dm3ConfigFusesIndex  
  DisplayString as dm3ConfigFusesName  
  INTEGER as dm3ConfigFusesAlarm  

Dm3StatusAlarmsEntry  
SEQUENCE    
  INTEGER as dm3StatusAlarmsIndex  
  DisplayString as dm3StatusAlarmsText  

Dm3StatusLVDEntry  
SEQUENCE    
  INTEGER as dm3StatusLVDIndex  
  DisplayString as dm3StatusLVDName  
  INTEGER as dm3StatusLVDState  
  INTEGER as dm3StatusLVDHwFault  

Dm3StatusRectEntry  
SEQUENCE    
  INTEGER as dm3StatusRectIndex  
  INTEGER as dm3StatusRectID  
  DisplayString as dm3StatusRectDesc  
  INTEGER as dm3StatusRectCurrent  
  INTEGER as dm3StatusRectCurrentLimit  
  INTEGER as dm3StatusRectStandby  
  INTEGER as dm3StatusRectFanFail  
  INTEGER as dm3StatusRectFail  
  INTEGER as dm3StatusRectDevType  
  INTEGER as dm3StatusRectPhyAddr  
  INTEGER as dm3StatusRectCfg  
  INTEGER as dm3StatusRectPcbRev  
  INTEGER as dm3StatusRectFwVer  
  INTEGER as dm3StatusRectPresent  
  INTEGER as dm3StatusRectDiagPass  
  INTEGER as dm3StatusRectState  

Dm3StatusConvEntry  
SEQUENCE    
  INTEGER as dm3StatusConvIndex  
  INTEGER as dm3StatusConvID  
  DisplayString as dm3StatusConvDesc  
  INTEGER as dm3StatusConvCurrent  
  INTEGER as dm3StatusConvCurrentLimit  
  INTEGER as dm3StatusConvStandby  
  INTEGER as dm3StatusConvFanFail  
  INTEGER as dm3StatusConvFail  
  INTEGER as dm3StatusConvDevType  
  INTEGER as dm3StatusConvPhyAddr  
  INTEGER as dm3StatusConvCfg  
  INTEGER as dm3StatusConvPcbRev  
  INTEGER as dm3StatusConvFwVer  
  INTEGER as dm3StatusConvPresent  
  INTEGER as dm3StatusConvDiagPass  
  INTEGER as dm3StatusConvState  

Dm3StatusOutRlyEntry  
SEQUENCE    
  INTEGER as dm3StatusOutRlyIndex  
  DisplayString as dm3StatusOutRlyName  
  INTEGER as dm3StatusOutRlyStatus  

Dm3StatusInRlyEntry  
SEQUENCE    
  INTEGER as dm3StatusInRlyIndex  
  DisplayString as dm3StatusInRlyName  
  INTEGER as dm3StatusInRlyStatus  

Dm3StatusBreakersEntry  
SEQUENCE    
  INTEGER as dm3StatusBreakersIndex  
  DisplayString as dm3StatusBreakersName  
  INTEGER as dm3StatusBreakersStatus  

Dm3StatusFusesEntry  
SEQUENCE    
  INTEGER as dm3StatusFusesIndex  
  DisplayString as dm3StatusFusesName  
  INTEGER as dm3StatusFusesStatus  

ATSCalibrationInputPhaseEntry  
SEQUENCE    
  INTEGER as atsCalibrationInputTableIndex  
  INTEGER as atsCalibrationInputPhaseTableIndex  
  INTEGER as atsLineVoltageCalibrationFactor  

ATSCalibrationPowerSupplyVoltageEntry  
SEQUENCE    
  INTEGER as atsCalibrationPowerSupplyVoltageTableIndex  
  INTEGER as atsCalibrationPowerSupplyVoltage  
  INTEGER as atsPowerSupplyVoltageCalibrationFactor  

ATSCalibrationOutputEntry  
SEQUENCE    
  INTEGER as atsCalibrationOutputTableIndex  
  INTEGER as atsCalibrationOutputPhasesTableIndex  
  INTEGER as atsOutputCurrentCalibrationFactor  

ATSConfigBankEntry  
SEQUENCE    
  INTEGER as atsConfigBankTableIndex  
  INTEGER as atsConfigBank  
  INTEGER as atsConfigBankLowLoadThreshold  
  INTEGER as atsConfigBankNearOverLoadThreshold  
  INTEGER as atsConfigBankOverLoadThreshold  

ATSConfigPhaseEntry  
SEQUENCE    
  INTEGER as atsConfigPhaseTableIndex  
  INTEGER as atsConfigPhase  
  INTEGER as atsConfigPhaseLowLoadThreshold  
  INTEGER as atsConfigPhaseNearOverLoadThreshold  
  INTEGER as atsConfigPhaseOverLoadThreshold  

AtsInputEntry  
SEQUENCE    
  INTEGER as atsInputTableIndex  
  INTEGER as atsNumInputPhases  
  INTEGER as atsInputVoltageOrientation  
  INTEGER as atsInputFrequency  
  INTEGER as atsInputType  
  DisplayString as atsInputName  

AtsInputPhaseEntry  
SEQUENCE    
  INTEGER as atsInputPhaseTableIndex  
  INTEGER as atsInputPhaseIndex  
  INTEGER as atsInputVoltage  
  INTEGER as atsInputMaxVoltage  
  INTEGER as atsInputMinVoltage  
  INTEGER as atsInputCurrent  
  INTEGER as atsInputMaxCurrent  
  INTEGER as atsInputMinCurrent  
  INTEGER as atsInputPower  
  INTEGER as atsInputMaxPower  
  INTEGER as atsInputMinPower  

AtsOutputEntry  
SEQUENCE    
  INTEGER as atsOutputTableIndex  
  INTEGER as atsNumOutputPhases  
  INTEGER as atsOutputVoltageOrientation  
  INTEGER as atsOutputFrequency  

AtsOutputPhaseEntry  
SEQUENCE    
  INTEGER as atsOutputPhaseTableIndex  
  INTEGER as atsOutputPhaseIndex  
  INTEGER as atsOutputVoltage  
  INTEGER as atsOutputCurrent  
  INTEGER as atsOutputMaxCurrent  
  INTEGER as atsOutputMinCurrent  
  INTEGER as atsOutputLoad  
  INTEGER as atsOutputMaxLoad  
  INTEGER as atsOutputMinLoad  
  INTEGER as atsOutputPercentLoad  
  INTEGER as atsOutputMaxPercentLoad  
  INTEGER as atsOutputMinPercentLoad  
  INTEGER as atsOutputPower  
  INTEGER as atsOutputMaxPower  
  INTEGER as atsOutputMinPower  
  INTEGER as atsOutputPercentPower  
  INTEGER as atsOutputMaxPercentPower  
  INTEGER as atsOutputMinPercentPower  
  INTEGER as atsOutputPhaseState  

ATSOutputBankEntry  
SEQUENCE    
  INTEGER as atsOutputBankTableIndex  
  INTEGER as atsOutputPhase  
  INTEGER as atsOutputBank  
  Gauge as atsOutputBankCurrent  
  INTEGER as atsOutputBankState  
  INTEGER as atsOutputBankOutputVoltage  
  INTEGER as atsOutputBankMaxCurrent  
  INTEGER as atsOutputBankMinCurrent  
  INTEGER as atsOutputBankLoad  
  INTEGER as atsOutputBankMaxLoad  
  INTEGER as atsOutputBankMinLoad  
  INTEGER as atsOutputBankPercentLoad  
  INTEGER as atsOutputBankMaxPercentLoad  
  INTEGER as atsOutputBankMinPercentLoad  
  INTEGER as atsOutputBankPower  
  INTEGER as atsOutputBankMaxPower  
  INTEGER as atsOutputBankMinPower  
  INTEGER as atsOutputBankPercentPower  
  INTEGER as atsOutputBankMaxPercentPower  
  INTEGER as atsOutputBankMinPercentPower  

Dcmim2ConfigLVDEntry  
SEQUENCE    
  INTEGER as dcmim2ConfigLVDIndex  
  INTEGER as dcmim2ConfigLVDTrip  
  INTEGER as dcmim2ConfigLVDReset  
  INTEGER as dcmim2ConfigLVDState  

Dcmim2StatusRectEntry  
SEQUENCE    
  INTEGER as dcmim2StatusRectIndex  
  INTEGER as dcmim2StatusRectDevType  
  INTEGER as dcmim2StatusRectID  
  INTEGER as dcmim2StatusRectPhyAddr  
  INTEGER as dcmim2StatusRectFail  
  INTEGER as dcmim2StatusRectCurrent  

Dcmim2StatusLVDEntry  
SEQUENCE    
  INTEGER as dcmim2StatusLVDIndex  
  INTEGER as dcmim2StatusLVDState  

Dcmim2StatusAlarmsEntry  
SEQUENCE    
  INTEGER as dcmim2StatusAlarmsIndex  
  DisplayString as dcmim2StatusAlarmsText  

EmConfigProbesEntry  
SEQUENCE    
  INTEGER as emConfigProbeNumber  
  DisplayString as emConfigProbeName  
  INTEGER as emConfigProbeHighTempThreshold  
  INTEGER as emConfigProbeLowTempThreshold  
  INTEGER as emConfigProbeTempUnits  
  INTEGER as emConfigProbeHighHumidThreshold  
  INTEGER as emConfigProbeLowHumidThreshold  
  INTEGER as emConfigProbeHighTempEnable  
  INTEGER as emConfigProbeLowTempEnable  
  INTEGER as emConfigProbeHighHumidEnable  
  INTEGER as emConfigProbeLowHumidEnable  
  INTEGER as emConfigProbeMaxTempThreshold  
  INTEGER as emConfigProbeMinTempThreshold  
  INTEGER as emConfigProbeMaxHumidThreshold  
  INTEGER as emConfigProbeMinHumidThreshold  
  INTEGER as emConfigProbeMaxTempEnable  
  INTEGER as emConfigProbeMinTempEnable  
  INTEGER as emConfigProbeMaxHumidEnable  
  INTEGER as emConfigProbeMinHumidEnable  
  INTEGER as emConfigProbeTempHysteresis  
  INTEGER as emConfigProbeHumidHysteresis  
  DisplayString as emConfigProbeLocation  

EmConfigContactsEntry  
SEQUENCE    
  INTEGER as emConfigContactNumber  
  DisplayString as emConfigContactName  
  INTEGER as emConfigContactEnable  
  INTEGER as emConfigContactSeverity  
  INTEGER as emConfigContactNormalState  
  DisplayString as emConfigContactLocation  

EmStatusProbesEntry  
SEQUENCE    
  INTEGER as emStatusProbeNumber  
  DisplayString as emStatusProbeName  
  INTEGER as emStatusProbeStatus  
  INTEGER as emStatusProbeCurrentTemp  
  INTEGER as emStatusProbeTempUnits  
  INTEGER as emStatusProbeCurrentHumid  
  INTEGER as emStatusProbeHighTempViolation  
  INTEGER as emStatusProbeLowTempViolation  
  INTEGER as emStatusProbeHighHumidViolation  
  INTEGER as emStatusProbeLowHumidViolation  
  INTEGER as emStatusProbeMaxTempViolation  
  INTEGER as emStatusProbeMinTempViolation  
  INTEGER as emStatusProbeMaxHumidViolation  
  INTEGER as emStatusProbeMinHumidViolation  

EmStatusContactsEntry  
SEQUENCE    
  INTEGER as emStatusContactNumber  
  DisplayString as emStatusContactName  
  INTEGER as emStatusContactStatus  

MemModulesStatusEntry  
SEQUENCE    
  INTEGER as memModulesStatusModuleNumber  
  DisplayString as memModulesStatusModuleName  
  DisplayString as memModulesStatusModuleLocation  
  DisplayString as memModulesStatusModelNumber  
  DisplayString as memModulesStatusSerialNumber  
  DisplayString as memModulesStatusFirmwareRev  
  DisplayString as memModulesStatusHardwareRev  

MemModulesConfigEntry  
SEQUENCE    
  INTEGER as memModulesConfigModuleNumber  
  DisplayString as memModulesConfigModuleName  
  DisplayString as memModulesConfigModuleLocation  

MemSensorsStatusEntry  
SEQUENCE    
  INTEGER as memSensorsStatusModuleNumber  
  INTEGER as memSensorsStatusSensorNumber  
  DisplayString as memSensorsStatusSensorName  
  DisplayString as memSensorsStatusSensorLocation  
  INTEGER as memSensorsTemperature  
  INTEGER as memSensorsHumidity  
  INTEGER as memSensorsCommStatus  
  INTEGER as memSensorsAlarmStatus  

MemSensorsConfigEntry  
SEQUENCE    
  INTEGER as memSensorsConfigModuleNumber  
  INTEGER as memSensorsConfigSensorNumber  
  DisplayString as memSensorsName  
  DisplayString as memSensorsLocation  
  INTEGER as memSensorsAlarmGeneration  
  INTEGER as memSensorsTempMaxThresh  
  INTEGER as memSensorsTempHighThresh  
  INTEGER as memSensorsTempLowThresh  
  INTEGER as memSensorsTempMinThresh  
  INTEGER as memSensorsTempThreshHysteresis  
  INTEGER as memSensorsTempShortDecRateThreshValue  
  INTEGER as memSensorsTempShortDecRateThreshTime  
  INTEGER as memSensorsTempShortIncRateThreshValue  
  INTEGER as memSensorsTempShortIncRateThreshTime  
  INTEGER as memSensorsTempLongDecRateThreshValue  
  INTEGER as memSensorsTempLongDecRateThreshTime  
  INTEGER as memSensorsTempLongIncRateThreshValue  
  INTEGER as memSensorsTempLongIncRateThreshTime  
  INTEGER as memSensorsHumidityMaxThresh  
  INTEGER as memSensorsHumidityHighThresh  
  INTEGER as memSensorsHumidityLowThresh  
  INTEGER as memSensorsHumidityMinThresh  
  INTEGER as memSensorsHumidityThreshHysteresis  

MemInputsStatusEntry  
SEQUENCE    
  INTEGER as memInputsStatusModuleNumber  
  INTEGER as memInputsStatusInputNumber  
  DisplayString as memInputsStatusInputName  
  DisplayString as memInputsStatusInputLocation  
  INTEGER as memInputsStatusCurrentState  
  DisplayString as memInputsStatusCurrentAnalogValue  
  INTEGER as memInputsStatusAlarmStatus  
  INTEGER as memInputsCommStatus  

MemInputsConfigEntry  
SEQUENCE    
  INTEGER as memInputsConfigModuleNumber  
  INTEGER as memInputsConfigInputNumber  
  DisplayString as memInputName  
  DisplayString as memInputLocation  
  INTEGER as memInputType  
  INTEGER as memInputAlarmGeneration  
  INTEGER as memInputNormalState  
  INTEGER as memInputAbnormalSeverity  
  INTEGER as memInputNumberCalibrationPoints  
  DisplayString as memInputAnalogCalibrationPoint1  
  DisplayString as memInputAnalogCalibrationPoint2  
  DisplayString as memInputAnalogCalibrationPoint3  
  DisplayString as memInputAnalogCalibrationPoint4  
  DisplayString as memInputAnalogCalibrationPoint5  
  DisplayString as memInputAnalogCalibrationPoint1Value  
  DisplayString as memInputAnalogCalibrationPoint2Value  
  DisplayString as memInputAnalogCalibrationPoint3Value  
  DisplayString as memInputAnalogCalibrationPoint4Value  
  DisplayString as memInputAnalogCalibrationPoint5Value  
  DisplayString as memInputAnalogMeasurementUnits  
  DisplayString as memInputAnalogMaxThresh  
  DisplayString as memInputAnalogHighThresh  
  DisplayString as memInputAnalogLowThresh  
  DisplayString as memInputAnalogMinThresh  
  DisplayString as memInputAnalogThreshHysteresis  

MemOutputStatusEntry  
SEQUENCE    
  INTEGER as memOutputStatusModuleNumber  
  INTEGER as memOutputStatusOutputNumber  
  DisplayString as memOutputStatusOutputName  
  DisplayString as memOutputStatusOutputLocation  
  INTEGER as memOutputStatusCurrentState  

MemOutputConfigEntry  
SEQUENCE    
  INTEGER as memOutputConfigModuleNumber  
  INTEGER as memOutputConfigOutputNumber  
  DisplayString as memOutputName  
  DisplayString as memOutputLocation  
  INTEGER as memOutputNormalState  
  INTEGER as memOutputAction  

MemOutletStatusEntry  
SEQUENCE    
  INTEGER as memOutletStatusModuleNumber  
  INTEGER as memOutletStatusOutletNumber  
  DisplayString as memOutletStatusOutletName  
  DisplayString as memOutletStatusOutletLocation  
  INTEGER as memOutletStatusCurrentState  

MemOutletConfigEntry  
SEQUENCE    
  INTEGER as memOutletConfigModuleNumber  
  INTEGER as memOutletConfigOutletNumber  
  DisplayString as memOutletName  
  DisplayString as memOutletLocation  
  INTEGER as memOutletNormalState  
  INTEGER as memOutletAction  

MemBeaconStatusEntry  
SEQUENCE    
  INTEGER as memBeaconStatusModuleNumber  
  INTEGER as memBeaconStatusBeaconNumber  
  DisplayString as memBeaconStatusBeaconName  
  DisplayString as memBeaconStatusBeaconLocation  
  INTEGER as memBeaconStatusCurrentState  

MemBeaconConfigEntry  
SEQUENCE    
  INTEGER as memBeaconConfigModuleNumber  
  INTEGER as memBeaconConfigBeaconNumber  
  DisplayString as memBeaconConfigName  
  DisplayString as memBeaconConfigLocation  
  INTEGER as memBeaconAction  

IemConfigProbesEntry  
SEQUENCE    
  INTEGER as iemConfigProbeNumber  
  DisplayString as iemConfigProbeName  
  INTEGER as iemConfigProbeHighTempThreshold  
  INTEGER as iemConfigProbeLowTempThreshold  
  INTEGER as iemConfigProbeTempUnits  
  INTEGER as iemConfigProbeHighHumidThreshold  
  INTEGER as iemConfigProbeLowHumidThreshold  
  INTEGER as iemConfigProbeHighTempEnable  
  INTEGER as iemConfigProbeLowTempEnable  
  INTEGER as iemConfigProbeHighHumidEnable  
  INTEGER as iemConfigProbeLowHumidEnable  
  INTEGER as iemConfigProbeMaxTempThreshold  
  INTEGER as iemConfigProbeMinTempThreshold  
  INTEGER as iemConfigProbeMaxHumidThreshold  
  INTEGER as iemConfigProbeMinHumidThreshold  
  INTEGER as iemConfigProbeMaxTempEnable  
  INTEGER as iemConfigProbeMinTempEnable  
  INTEGER as iemConfigProbeMaxHumidEnable  
  INTEGER as iemConfigProbeMinHumidEnable  
  INTEGER as iemConfigProbeTempHysteresis  
  INTEGER as iemConfigProbeHumidHysteresis  
  DisplayString as iemConfigProbeLocation  

IemConfigContactsEntry  
SEQUENCE    
  INTEGER as iemConfigContactNumber  
  DisplayString as iemConfigContactName  
  INTEGER as iemConfigContactEnable  
  INTEGER as iemConfigContactSeverity  
  INTEGER as iemConfigContactNormalState  
  DisplayString as iemConfigContactLocation  

IemConfigRelaysEntry  
SEQUENCE    
  INTEGER as iemConfigRelayNumber  
  DisplayString as iemConfigRelayName  
  INTEGER as iemConfigRelayNormalState  
  INTEGER as iemConfigRelayFaultCondition  

IemStatusProbesEntry  
SEQUENCE    
  INTEGER as iemStatusProbeNumber  
  DisplayString as iemStatusProbeName  
  INTEGER as iemStatusProbeStatus  
  INTEGER as iemStatusProbeCurrentTemp  
  INTEGER as iemStatusProbeTempUnits  
  INTEGER as iemStatusProbeCurrentHumid  
  INTEGER as iemStatusProbeHighTempViolation  
  INTEGER as iemStatusProbeLowTempViolation  
  INTEGER as iemStatusProbeHighHumidViolation  
  INTEGER as iemStatusProbeLowHumidViolation  
  INTEGER as iemStatusProbeMaxTempViolation  
  INTEGER as iemStatusProbeMinTempViolation  
  INTEGER as iemStatusProbeMaxHumidViolation  
  INTEGER as iemStatusProbeMinHumidViolation  
  DisplayString as iemStatusProbeLocation  

IemStatusContactsEntry  
SEQUENCE    
  INTEGER as iemStatusContactNumber  
  DisplayString as iemStatusContactName  
  INTEGER as iemStatusContactStatus  

IemStatusRelaysEntry  
SEQUENCE    
  INTEGER as iemStatusRelayNumber  
  DisplayString as iemStatusRelayName  
  INTEGER as iemStatusRelayStatus  

EmsOutputRelayControlEntry  
SEQUENCE    
  INTEGER as emsOutputRelayControlOutputRelayIndex  
  DisplayString as emsOutputRelayControlOutputRelayName  
  INTEGER as emsOutputRelayControlOutputRelayCommand  

EmsOutletControlEntry  
SEQUENCE    
  INTEGER as emsOutletControlOutletIndex  
  DisplayString as emsOutletControlOutletName  
  INTEGER as emsOutletControlOutletCommand  

EMSSensorControlEntry  
SEQUENCE    
  INTEGER as emsSensorControlSensorIndex  
  DisplayString as emsSensorControlSensorSystemName  
  DisplayString as emsSensorControlSensorUserName  
  INTEGER as emsSensorControlSensorCommand  

EmsAlarmDeviceControlEntry  
SEQUENCE    
  INTEGER as emsAlarmDeviceControlDeviceIndex  
  DisplayString as emsAlarmDeviceControlDeviceName  
  INTEGER as emsAlarmDeviceControlDeviceCommand  

EMSProbeConfigEntry  
SEQUENCE    
  INTEGER as emsProbeConfigProbeIndex  
  DisplayString as emsProbeConfigProbeName  
  INTEGER as emsProbeConfigProbeHighTempThresh  
  INTEGER as emsProbeConfigProbeLowTempThresh  
  INTEGER as emsProbeConfigProbeHighHumidityThresh  
  INTEGER as emsProbeConfigProbeLowHumidityThresh  
  INTEGER as emsProbeConfigProbeMaxTempThresh  
  INTEGER as emsProbeConfigProbeMinTempThresh  
  INTEGER as emsProbeConfigProbeDeltaTemp  
  INTEGER as emsProbeConfigProbeMaxHumidityThresh  
  INTEGER as emsProbeConfigProbeMinHumidityThresh  
  INTEGER as emsProbeConfigProbeDeltaHumidity  
  INTEGER as emsProbeConfigProbeSTIncTempVariance  
  INTEGER as emsProbeConfigProbeSTIncTempTime  
  INTEGER as emsProbeConfigProbeSTDecTempVariance  
  INTEGER as emsProbeConfigProbeSTDecTempTime  
  INTEGER as emsProbeConfigProbeLTIncTempVariance  
  INTEGER as emsProbeConfigProbeLTIncTempTime  
  INTEGER as emsProbeConfigProbeLTDecTempVariance  
  INTEGER as emsProbeConfigProbeLTDecTempTime  

EMSInputContactConfigEntry  
SEQUENCE    
  INTEGER as emsInputContactConfigInputContactIndex  
  DisplayString as emsInputContactConfigInputContactName  
  INTEGER as emsInputContactConfigInputContactNormalState  

EMSOutputRelayConfigEntry  
SEQUENCE    
  INTEGER as emsOutputRelayConfigOutputRelayIndex  
  DisplayString as emsOutputRelayConfigOutputRelayName  
  INTEGER as emsOutputRelayConfigOutputRelayNormalState  

EMSOutletConfigEntry  
SEQUENCE    
  INTEGER as emsOutletConfigOutletIndex  
  DisplayString as emsOutletConfigOutletName  
  INTEGER as emsOutletConfigOutletNormalState  

EMSSensorConfigEntry  
SEQUENCE    
  INTEGER as emsSensorConfigSensorIndex  
  DisplayString as emsSensorConfigSensorSystemName  
  DisplayString as emsSensorConfigSensorUserName  
  INTEGER as emsSensorConfigSensorNormalState  
  INTEGER as emsSensorConfigSensorAlarmDelay  

EMSProbeStatusEntry  
SEQUENCE    
  INTEGER as emsProbeStatusProbeIndex  
  DisplayString as emsProbeStatusProbeName  
  INTEGER as emsProbeStatusProbeTemperature  
  INTEGER as emsProbeStatusProbeHighTempThresh  
  INTEGER as emsProbeStatusProbeLowTempThresh  
  INTEGER as emsProbeStatusProbeHumidity  
  INTEGER as emsProbeStatusProbeHighHumidityThresh  
  INTEGER as emsProbeStatusProbeLowHumidityThresh  
  DisplayString as emsProbeStatusProbeSerialNumber  
  INTEGER as emsProbeStatusProbeCommStatus  
  INTEGER as emsProbeStatusProbeAlarmStatus  
  INTEGER as emsProbeStatusProbeMaxTempThresh  
  INTEGER as emsProbeStatusProbeMinTempThresh  
  INTEGER as emsProbeStatusProbeMaxHumidityThresh  
  INTEGER as emsProbeStatusProbeMinHumidityThresh  

EMSInputContactStatusEntry  
SEQUENCE    
  INTEGER as emsInputContactStatusInputContactIndex  
  DisplayString as emsInputContactStatusInputContactName  
  INTEGER as emsInputContactStatusInputContactState  
  INTEGER as emsInputContactStatusInputContactNormalState  

EMSOutputRelayStatusEntry  
SEQUENCE    
  INTEGER as emsOutputRelayStatusOutputRelayIndex  
  DisplayString as emsOutputRelayStatusOutputRelayName  
  INTEGER as emsOutputRelayStatusOutputRelayState  
  INTEGER as emsOutputRelayStatusOutputRelayNormalState  

EMSOutletStatusEntry  
SEQUENCE    
  INTEGER as emsOutletStatusOutletIndex  
  DisplayString as emsOutletStatusOutletName  
  INTEGER as emsOutletStatusOutletState  
  INTEGER as emsOutletStatusOutletNormalState  

EMSAlarmDeviceStatusEntry  
SEQUENCE    
  INTEGER as emsAlarmDeviceStatusDeviceIndex  
  DisplayString as emsAlarmDeviceStatusDeviceName  
  INTEGER as emsAlarmDeviceStatusDeviceState  

EMSSensorStatusEntry  
SEQUENCE    
  INTEGER as emsSensorStatusSensorIndex  
  DisplayString as emsSensorStatusSensorSystemName  
  DisplayString as emsSensorStatusSensorName  
  INTEGER as emsSensorStatusSensorState  
  INTEGER as emsSensorStatusSensorNormalState  
  INTEGER as emsSensorStatusSensorAlarmDelay  

AirFMIdentEntry  
SEQUENCE    
  INTEGER as airFMIdentModuleIndex  
  DisplayString as airFMIdentModuleModelNumber  
  DisplayString as airFMIdentModuleDateOfMfg  
  DisplayString as airFMIdentModuleSerialNumber  
  DisplayString as airFMIdentModuleFirmwareRev  
  DisplayString as airFMIdentModuleHardwareRev  

AirFMStatusModuleEntry  
SEQUENCE    
  INTEGER as airFMStatusModuleIndex  
  INTEGER as airFMStatusModuleOutputCapacity  
  INTEGER as airFMStatusModuleSupplyTempC  
  INTEGER as airFMStatusModuleSupplyTempF  
  INTEGER as airFMStatusModuleSupplyHum  
  INTEGER as airFMStatusModuleReturnTempC  
  INTEGER as airFMStatusModuleReturnTempF  
  INTEGER as airFMStatusModuleReturnHum  

AirFMGroupSysRolesEntry  
SEQUENCE    
  INTEGER as airFMGroupSysIndex  
  INTEGER as airFMGroupSysRoleStatus  
  INTEGER as airFMGroupSysPresentRole  
  INTEGER as airFMGroupSysManualRoleSetting  
  INTEGER as airFMGroupSysRunHours  
  INTEGER as airFMGroupSysComm  
  IpAddress as airFMGroupSysIPAddress  

AirFMSysInputEntry  
SEQUENCE    
  INTEGER as airFMSysInputIndex  
  DisplayString as airFMSysInputName  
  INTEGER as airFMSysInputStatus  
  INTEGER as airFMSysInputNormalState  
  INTEGER as airFMSysInputDelay  
  INTEGER as airFMSysInputAlarmAction  

AirFMSysOutputEntry  
SEQUENCE    
  INTEGER as airFMSysOutputIndex  
  INTEGER as airFMSysOutputStatus  
  INTEGER as airFMSysOutputNormalState  

AirFMSysAlarmMapSysEntry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapSysOutputIndex  
  INTEGER as airFMSysAlarmMapSysAnyAlarm  
  INTEGER as airFMSysAlarmMapSystemOn  
  INTEGER as airFMSysAlarmMapSystemOffline  
  INTEGER as airFMSysAlarmMapSysHighEnvTemp  
  INTEGER as airFMSysAlarmMapSysLowEnvTemp  
  INTEGER as airFMSysAlarmMapSysHighEnvHum  
  INTEGER as airFMSysAlarmMapSysLowEnvHum  
  INTEGER as airFMSysAlarmMapSysFireDet  
  INTEGER as airFMSysAlarmMapSysSmokeDet  
  INTEGER as airFMSysAlarmMapSysEconIsol  
  INTEGER as airFMSysAlarmMapSysSupplySensFail  
  INTEGER as airFMSysAlarmMapSysReturnSensFail  
  INTEGER as airFMSysAlarmMapSysRemSensRemoved  
  INTEGER as airFMSysAlarmMapSysPrimSensFail  
  INTEGER as airFMSysAlarmMapSysSecSensFail  
  INTEGER as airFMSysAlarmMapSysSecSensActive  

AirFMSysAlarmMapMainModEntry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapMainModOutputIndex  
  INTEGER as airFMSysAlarmMapMainModAnyAlarm  
  INTEGER as airFMSysAlarmMapMainModMaintReq  
  INTEGER as airFMSysAlarmMapMainModCoolFail  
  INTEGER as airFMSysAlarmMapMainModHighSupplyTemp  
  INTEGER as airFMSysAlarmMapMainModLowSupplyTemp  
  INTEGER as airFMSysAlarmMapMainModHumFail  
  INTEGER as airFMSysAlarmMapMainModHumReplCyl  
  INTEGER as airFMSysAlarmMapMainModCondPumpFail  
  INTEGER as airFMSysAlarmMapMainModBlwrCntl1Fail  
  INTEGER as airFMSysAlarmMapMainModBlwrCntl2Fail  
  INTEGER as airFMSysAlarmMapMainModHighFltrDP  
  INTEGER as airFMSysAlarmMapMainModLowAirFlow  
  INTEGER as airFMSysAlarmMapMainModAirBlckIntOpen  
  INTEGER as airFMSysAlarmMapMainModWaterDetected  

AirFMSysAlarmMapExpMod1Entry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapExpMod1OutputIndex  
  INTEGER as airFMSysAlarmMapExpMod1AnyAlarm  
  INTEGER as airFMSysAlarmMapExpMod1MaintReq  
  INTEGER as airFMSysAlarmMapExpMod1CoolFail  
  INTEGER as airFMSysAlarmMapExpMod1HighSupplyTemp  
  INTEGER as airFMSysAlarmMapExpMod1LowSupplyTemp  
  INTEGER as airFMSysAlarmMapExpMod1HumFail  
  INTEGER as airFMSysAlarmMapExpMod1HumReplCyl  
  INTEGER as airFMSysAlarmMapExpMod1CondPumpFail  
  INTEGER as airFMSysAlarmMapExpMod1BlwrCntl1Fail  
  INTEGER as airFMSysAlarmMapExpMod1BlwrCntl2Fail  
  INTEGER as airFMSysAlarmMapExpMod1HighFltrDP  
  INTEGER as airFMSysAlarmMapExpMod1LowAirFlow  
  INTEGER as airFMSysAlarmMapExpMod1AirBlckIntOpen  
  INTEGER as airFMSysAlarmMapExpMod1WaterDetected  

AirFMSysAlarmMapExpMod2Entry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapExpMod2OutputIndex  
  INTEGER as airFMSysAlarmMapExpMod2AnyAlarm  
  INTEGER as airFMSysAlarmMapExpMod2MaintReq  
  INTEGER as airFMSysAlarmMapExpMod2CoolFail  
  INTEGER as airFMSysAlarmMapExpMod2HighSupplyTemp  
  INTEGER as airFMSysAlarmMapExpMod2LowSupplyTemp  
  INTEGER as airFMSysAlarmMapExpMod2HumFail  
  INTEGER as airFMSysAlarmMapExpMod2HumReplCyl  
  INTEGER as airFMSysAlarmMapExpMod2CondPumpFail  
  INTEGER as airFMSysAlarmMapExpMod2BlwrCntl1Fail  
  INTEGER as airFMSysAlarmMapExpMod2BlwrCntl2Fail  
  INTEGER as airFMSysAlarmMapExpMod2HighFltrDP  
  INTEGER as airFMSysAlarmMapExpMod2LowAirFlow  
  INTEGER as airFMSysAlarmMapExpMod2AirBlckIntOpen  
  INTEGER as airFMSysAlarmMapExpMod2WaterDetected  

AirFMSysAlarmMapInputEntry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapInputOutputIndex  
  INTEGER as airFMSysAlarmMapInput1  
  INTEGER as airFMSysAlarmMapInput2  
  INTEGER as airFMSysAlarmMapInput3  
  INTEGER as airFMSysAlarmMapInput4  
  INTEGER as airFMSysAlarmMapInput5  
  INTEGER as airFMSysAlarmMapInput6  
  INTEGER as airFMSysAlarmMapInput7  
  INTEGER as airFMSysAlarmMapInput8  
  INTEGER as airFMSysAlarmMapInput9  
  INTEGER as airFMSysAlarmMapInput10  
  INTEGER as airFMSysAlarmMapInput11  
  INTEGER as airFMSysAlarmMapInput12  
  INTEGER as airFMSysAlarmMapInput13  
  INTEGER as airFMSysAlarmMapInput14  
  INTEGER as airFMSysAlarmMapInput15  
  INTEGER as airFMSysAlarmMapInput16  

AirFMSysAlarmMapOutputEntry  
SEQUENCE    
  INTEGER as airFMSysAlarmMapOutputIndex  
  INTEGER as airFMSysAlarmMapOutput1  
  INTEGER as airFMSysAlarmMapOutput2  
  INTEGER as airFMSysAlarmMapOutput3  
  INTEGER as airFMSysAlarmMapOutput4  
  INTEGER as airFMSysAlarmMapOutput5  
  INTEGER as airFMSysAlarmMapOutput6  
  INTEGER as airFMSysAlarmMapOutput7  
  INTEGER as airFMSysAlarmMapOutput8  
  INTEGER as airFMSysAlarmMapOutput9  
  INTEGER as airFMSysAlarmMapOutput10  
  INTEGER as airFMSysAlarmMapOutput11  
  INTEGER as airFMSysAlarmMapOutput12  
  INTEGER as airFMSysAlarmMapOutput13  
  INTEGER as airFMSysAlarmMapOutput14  
  INTEGER as airFMSysAlarmMapOutput15  
  INTEGER as airFMSysAlarmMapOutput16  

AirFMModIdentEntry  
SEQUENCE    
  INTEGER as airFMModIdentModuleIndex  
  DisplayString as airFMModModelNumber  
  DisplayString as airFMModSerialNumber  
  DisplayString as airFMModManufactureDate  
  DisplayString as airFMModFirmwareRev  
  DisplayString as airFMModHardwareRev  

AirFMModStatusEntry  
SEQUENCE    
  INTEGER as airFMModStatusModuleIndex  
  INTEGER as airFMModSupplyTempC  
  INTEGER as airFMModSupplyTempF  
  INTEGER as airFMModSupplyHum  
  INTEGER as airFMModReturnTempC  
  INTEGER as airFMModReturnTempF  
  INTEGER as airFMModReturnHum  
  INTEGER as airFMModFilterDiffPresPa  
  INTEGER as airFMModFilterDiffPresInWC  
  INTEGER as airFMModCoilDiffPresPa  
  INTEGER as airFMModCoilDiffPresInWC  

AirFMModPropEntry  
SEQUENCE    
  INTEGER as airFMModPropModuleIndex  
  INTEGER as airFMModOutputCapacity  
  INTEGER as airFMModCapacityCtrl  
  INTEGER as airFMModHeaterType  
  INTEGER as airFMModElectricHeaterType  
  INTEGER as airFMModHumidifierType  
  INTEGER as airFMModBlwrFreqSetting  
  INTEGER as airFMModNomCoilDiffPresPa  
  INTEGER as airFMModNomCoilDiffPresInWC  
  INTEGER as airFMModCondPump  
  INTEGER as airFMModFireDetector  
  INTEGER as airFMModSmokeDetector  
  INTEGER as airFMModWaterDetector  

AirFMModCoolEntry  
SEQUENCE    
  INTEGER as airFMModCoolModuleIndex  
  INTEGER as airFMModComp1  
  INTEGER as airFMModComp2  
  INTEGER as airFMModSuctPresKPa  
  INTEGER as airFMModSuctPresPSI  
  INTEGER as airFMModDischPresKPa  
  INTEGER as airFMModDischPresPSI  
  INTEGER as airFMModCondFluidVlvPos  
  INTEGER as airFMModCoilFluidVlvPos  

AirFMModHumEntry  
SEQUENCE    
  INTEGER as airFMModHumModuleIndex  
  INTEGER as airFMModHumidifier  
  INTEGER as airFMModElectrodeCurrent  
  INTEGER as airFMModHumActualOutput  
  INTEGER as airFMModWaterConductivity  
  INTEGER as airFMModHotWaterVlvPos  
  INTEGER as airFMModStmElectHumMode  

AirFMModBlwr1Entry  
SEQUENCE    
  INTEGER as airFMModBlwr1ModuleIndex  
  INTEGER as airFMModBlwr1CtrlType  
  INTEGER as airFMModBlwr1CmdFreq  
  INTEGER as airFMModBlwr1ActFreq  
  INTEGER as airFMModBlwr1Poles  
  INTEGER as airFMModBlwr1RatedHorsePower  
  INTEGER as airFMModBlwr1RatedCurrent  
  INTEGER as airFMModBlwr1ActTorq  
  INTEGER as airFMModBlwr1Current  
  INTEGER as airFMModBlwr1Vlt  
  INTEGER as airFMModBlwr1DCLinkVlt  
  INTEGER as airFMModBlwr1AccTime  
  INTEGER as airFMModBlwr1DecTime  
  INTEGER as airFMModBlwr1CapLife  
  INTEGER as airFMModBlwr1CtrlCoolFanLife  
  INTEGER as airFMModBlwr1ElOvMode  
  INTEGER as airFMModBlwr1ElOvSetting  
  INTEGER as airFMModBlwr1ElOvTimeConst  
  INTEGER as airFMModBlwr1FanPower  
  INTEGER as airFMModBlwr1HeatsinkTempC  
  INTEGER as airFMModBlwr1HeatsinkTempF  
  INTEGER as airFMModBlwr1ChokeTempC  
  INTEGER as airFMModBlwr1ChokeTempF  
  INTEGER as airFMModBlwr1InverterTempC  
  INTEGER as airFMModBlwr1InverterTempF  

AirFMModBlwr2Entry  
SEQUENCE    
  INTEGER as airFMModBlwr2ModuleIndex  
  INTEGER as airFMModBlwr2CtrlType  
  INTEGER as airFMModBlwr2CmdFreq  
  INTEGER as airFMModBlwr2ActFreq  
  INTEGER as airFMModBlwr2Poles  
  INTEGER as airFMModBlwr2RatedHorsePower  
  INTEGER as airFMModBlwr2RatedCurrent  
  INTEGER as airFMModBlwr2ActTorq  
  INTEGER as airFMModBlwr2Current  
  INTEGER as airFMModBlwr2Vlt  
  INTEGER as airFMModBlwr2DCLinkVlt  
  INTEGER as airFMModBlwr2AccTime  
  INTEGER as airFMModBlwr2DecTime  
  INTEGER as airFMModBlwr2CapLife  
  INTEGER as airFMModBlwr2CtrlCoolFanLife  
  INTEGER as airFMModBlwr2ElOvMode  
  INTEGER as airFMModBlwr2ElOvSetting  
  INTEGER as airFMModBlwr2ElOvTimeConst  
  INTEGER as airFMModBlwr2FanPower  
  INTEGER as airFMModBlwr2HeatsinkTempC  
  INTEGER as airFMModBlwr2HeatsinkTempF  
  INTEGER as airFMModBlwr2ChokeTempC  
  INTEGER as airFMModBlwr2ChokeTempF  
  INTEGER as airFMModBlwr2InverterTempC  
  INTEGER as airFMModBlwr2InverterTempF  

AirFMModRHEntry  
SEQUENCE    
  INTEGER as airFMModRHModuleIndex  
  INTEGER as airFMModRHComp1  
  INTEGER as airFMModRHComp2  
  INTEGER as airFMModRHHeater  
  INTEGER as airFMModRHHum  
  INTEGER as airFMModRHBlwr1  
  INTEGER as airFMModRHBlwr2  
  INTEGER as airFMModRHBlwrCtrl1  
  INTEGER as airFMModRHBlwrCtrl2  
  INTEGER as airFMModRHComp1Reset  
  INTEGER as airFMModRHComp2Reset  
  INTEGER as airFMModRHHeaterReset  
  INTEGER as airFMModRHHumReset  
  INTEGER as airFMModRHBlwr1Reset  
  INTEGER as airFMModRHBlwr2Reset  

AirFMModServIntResetEntry  
SEQUENCE    
  INTEGER as airFMModServIntResetModuleIndex  
  INTEGER as airFMModServIntComp1Reset  
  INTEGER as airFMModServIntComp2Reset  
  INTEGER as airFMModServIntHeaterReset  
  INTEGER as airFMModServIntHumReset  
  INTEGER as airFMModServIntBlwr1Reset  
  INTEGER as airFMModServIntBlwr2Reset  
  INTEGER as airFMModServIntBlwrCtrl1Reset  
  INTEGER as airFMModServIntBlwrCtrl2Reset  

AirFMAlarmConditionsEntry  
SEQUENCE    
  INTEGER as airFMAlarmConditionsIndex  
  INTEGER as airFMAlarmSeverity  
  INTEGER as airFMAlarmType  
  INTEGER as airFMEventCode  
  DisplayString as airFMAlarmDate  
  DisplayString as airFMAlarmTime  
  DisplayString as airFMAlarmDescription  

AirIRAlarmConditionsEntry  
SEQUENCE    
  INTEGER as airIRAlarmConditionsIndex  
  INTEGER as airIREventCode  
  DisplayString as airIRAlarmDescription  

AirIRSCConfigType  
INTEGER racs(1), spot(2), in-row(3)    

AirIRSCCapacityControlType  
INTEGER discrete(1), proportional(2)    

AirIRSCFanSpeedPreference  
INTEGER low(1), med-low(2), med(3), med-high(4), high(5)    

AirIRSCFanSpeedControl  
INTEGER automatic(1), manual(2)    

AirIRG2AlarmsEntry  
SEQUENCE    
  INTEGER as airIRG2AlarmsIndex  
  INTEGER as airIRG2AlarmsEventCode  
  DisplayString as airIRG2AlarmsDescription  

AirIRG2RDType2IOState  
INTEGER open(1), closed(2)    

AirIRG2RDT2RunHoursFanPSEntry  
SEQUENCE    
  INTEGER as airIRG2RDT2RunHoursFanPSIndex  
  INTEGER as airIRG2RDT2RunHoursFanPSPosition  
  INTEGER as airIRG2RDT2RunHoursFanPSHours  

AirIRG2RDT2RunHoursEvapFanEntry  
SEQUENCE    
  INTEGER as airIRG2RDT2RunHoursEvapFanIndex  
  INTEGER as airIRG2RDT2RunHoursEvapFanHours  

AirIRmAlarmState  
INTEGER ok(1), alarm(2)    

AirIRmControlState  
INTEGER off(1), on(2)    

AirIRmStopState  
INTEGER maybeOn(1), unitOff(2)    

AirIRmActivityState  
INTEGER inactive(1), active(2)    

AirIRmAlarmsEntry  
SEQUENCE    
  INTEGER as airIRmAlarmsIndex  
  INTEGER as airIRmAlarmsEventCode  
  DisplayString as airIRmAlarmsDescription  

AirIRG3IdentEntry  
SEQUENCE    
  INTEGER as airIRG3IdentIndex  
  DisplayString as airIRG3IdentName  
  DisplayString as airIRG3IdentLocation  
  DisplayString as airIRG3IdentModelNumber  
  DisplayString as airIRG3IdentSerialNumber  
  DisplayString as airIRG3IdentFirmwareRevision  
  DisplayString as airIRG3IdentHardwareRevision  
  DisplayString as airIRG3IdentManufactureDate  
  OBJECT IDENTIFIER as airIRG3IdentRDUSysOID  
  OBJECT IDENTIFIER as airIRG3IdentCMSysOID  
  OBJECT IDENTIFIER as airIRG3IdentGroupSysOID  

AirIRG3GroupStatusEntry  
SEQUENCE    
  INTEGER as airIRG3GroupStatusIndex  
  INTEGER as airIRG3GroupStatusCoolOutput  
  INTEGER as airIRG3GroupStatusCoolDemand  
  INTEGER as airIRG3GroupStatusAirFlowUS  
  INTEGER as airIRG3GroupStatusAirFlowMetric  
  INTEGER as airIRG3GroupStatusMaxRackInletTempUS  
  INTEGER as airIRG3GroupStatusMaxRackInletTempMetric  
  INTEGER as airIRG3GroupStatusMinRackInletTempUS  
  INTEGER as airIRG3GroupStatusMinRackInletTempMetric  
  INTEGER as airIRG3GroupStatusMaxReturnAirTempUS  
  INTEGER as airIRG3GroupStatusMaxReturnAirTempMetric  
  INTEGER as airIRG3GroupStatusMinReturnAirTempUS  
  INTEGER as airIRG3GroupStatusMinReturnAirTempMetric  
  INTEGER as airIRG3GroupStatusAvgSupplyTempUS  
  INTEGER as airIRG3GroupStatusAvgSupplyTempMetric  
  INTEGER as airIRG3GroupStatusAvgReturnTempUS  
  INTEGER as airIRG3GroupStatusAvgReturnTempMetric  
  INTEGER as airIRG3GroupStatusAvgFanSpeed  
  INTEGER as airIRG3GroupStatusAvgAirFlowUS  
  INTEGER as airIRG3GroupStatusAvgAirFlowMetric  
  INTEGER as airIRG3GroupStatusTotalAirFlowUS  
  INTEGER as airIRG3GroupStatusTotalAirFlowMetric  

AirIRG3GroupSetpointsEntry  
SEQUENCE    
  INTEGER as airIRG3GroupSetpointsIndex  
  INTEGER as airIRG3GroupSetpointsCoolSetpointUS  
  INTEGER as airIRG3GroupSetpointsCoolSetpointMetric  
  INTEGER as airIRG3GroupSetpointsCoolDeadbandUS  
  INTEGER as airIRG3GroupSetpointsCoolDeadbandMetric  
  INTEGER as airIRG3GroupSetpointsFanSpeedPreference  
  INTEGER as airIRG3GroupSetpointsSupplyAirSetpointUS  
  INTEGER as airIRG3GroupSetpointsSupplyAirSetpointMetric  
  INTEGER as airIRG3GroupSetpointsAirFlowControl  
  INTEGER as airIRG3GroupSetpointsLightingOnTime  

AirIRG3GroupConfigEntry  
SEQUENCE    
  INTEGER as airIRG3GroupConfigIndex  
  INTEGER as airIRG3GroupConfigNumberofCoolingUnits  
  INTEGER as airIRG3GroupConfigConfigurationType  
  INTEGER as airIRG3GroupConfigCapacityControlType  
  INTEGER as airIRG3GroupConfigFanSpeedControl  
  INTEGER as airIRG3GroupConfigCoolGainP  
  INTEGER as airIRG3GroupConfigCoolResetRateI  
  INTEGER as airIRG3GroupConfigCoolDerivativeD  
  INTEGER as airIRG3GroupConfigCoolPIDReset  
  INTEGER as airIRG3GroupConfigNumberofBackupUnits  
  INTEGER as airIRG3GroupConfigRuntimeBalancingEnable  
  INTEGER as airIRG3GroupConfigLoadAssistEnable  

AirIRG3AlarmsEntry  
SEQUENCE    
  INTEGER as airIRG3AlarmsIndex  
  INTEGER as airIRG3AlarmsEventCode  
  DisplayString as airIRG3AlarmsDescription  

AirIRG3RDUStatusEntry  
SEQUENCE    
  INTEGER as airIRG3RDUStatusDeviceIndex  
  DisplayString as airIRG3RDUID  
  INTEGER as airIRG3RDUStatusOnReadyStandby  
  INTEGER as airIRG3RDUStatusOperatingMode  
  INTEGER as airIRG3RDUStatusLeadPump  
  INTEGER as airIRG3RDUStatusStartupDelay  
  INTEGER as airIRG3RDUStatusPumpChangeOverInterval  
  INTEGER as airIRG3RDUStatusStopOnLeakDetect  
  INTEGER as airIRG3RDUStatusPowerSource  
  INTEGER as airIRG3RDUStatusTotalRDUOutputPower  
  INTEGER as airIRG3RDUStatusInletWaterTempUS  
  INTEGER as airIRG3RDUStatusInletWaterTempMetric  
  INTEGER as airIRG3RDUStatusOutletWaterTempUS  
  INTEGER as airIRG3RDUStatusOutletWaterTempMetric  
  INTEGER as airIRG3RDUStatusCondenserSaturationTempUS  
  INTEGER as airIRG3RDUStatusCondenserSaturationTempMetric  
  INTEGER as airIRG3RDUStatusDewPointTempUS  
  INTEGER as airIRG3RDUStatusDewPointTempMetric  
  INTEGER as airIRG3RDUStatusPumpOutletTempUS  
  INTEGER as airIRG3RDUStatusPumpOutletTempMetric  
  INTEGER as airIRG3RDUStatusSubcoolerOutletTempUS  
  INTEGER as airIRG3RDUStatusSubcoolerOutletTempMetric  
  INTEGER as airIRG3RDUStatusCondenserOutletTempUS  
  INTEGER as airIRG3RDUStatusCondenserOutletTempMetric  
  INTEGER as airIRG3RDUStatusCondenserInletTempUS  
  INTEGER as airIRG3RDUStatusCondenserInletTempMetric  
  INTEGER as airIRG3RDUStatusCondenserOutletPressureUS  
  INTEGER as airIRG3RDUStatusCondenserOutletPressureMetric  
  INTEGER as airIRG3RDUStatusPump1HeadPressureUS  
  INTEGER as airIRG3RDUStatusPump1HeadPressureMetric  
  INTEGER as airIRG3RDUStatusPump2HeadPressureUS  
  INTEGER as airIRG3RDUStatusPump2HeadPressureMetric  
  INTEGER as airIRG3RDUStatusPump1Speed  
  INTEGER as airIRG3RDUStatusPump2Speed  
  INTEGER as airIRG3RDUStatusCWValvePosition  
  INTEGER as airIRG3RDUStatusReceiverLiquidLevel  
  INTEGER as airIRG3RDUStatusDCPowerSupply1Current  
  INTEGER as airIRG3RDUStatusDCPowerSupply2Current  
  INTEGER as airIRG3RDUStatusTotalDCPowerSupplyCurrent  
  INTEGER as airIRG3RDUStatusInputState  
  INTEGER as airIRG3RDUStatusOutputState  
  INTEGER as airIRG3RDUStatusByPassValvePosition  
  INTEGER as airIRG3RDUStatusRefrigerantLeakDetector  

AirIRG3RDURunHoursEntry  
SEQUENCE    
  INTEGER as airIRG3RDURunHoursDeviceIndex  
  DisplayString as airIRG3RDURunHoursRDUID  
  INTEGER as airIRG3RDURunHoursPump1  
  INTEGER as airIRG3RDURunHoursPump2  
  INTEGER as airIRG3RDURunHoursPowerSupply1  
  INTEGER as airIRG3RDURunHoursPowerSupply2  

AirIRG3RDUServiceIntervalsEntry  
SEQUENCE    
  INTEGER as airIRG3RDUServiceIntervalsDeviceIndex  
  DisplayString as airIRG3RDUServiceIntervalsRDUID  
  INTEGER as airIRG3RDUServiceIntervalsAirFilterInterval  
  INTEGER as airIRG3RDUServiceIntervalsAirFilterAlarm  

AirIRG3RDUThresholdsEntry  
SEQUENCE    
  INTEGER as airIRG3RDUThresholdsDeviceIndex  
  DisplayString as airIRG3RDUThresholdsRDUID  
  INTEGER as airIRG3RDUThresholdsEnteringFluidTempHighUS  
  INTEGER as airIRG3RDUThresholdsEnteringFluidTempHighMetric  

AirIRG3RDUSetpointsEntry  
SEQUENCE    
  INTEGER as airIRG3RDUSetpointsDeviceIndex  

AirIRG3RDUConfigEntry  
SEQUENCE    
  INTEGER as airIRG3RDUConfigDeviceIndex  
  DisplayString as airIRG3RDUConfigRDUID  
  INTEGER as airIRG3RDUConfigStopOnLeakDetect  
  INTEGER as airIRG3RDUConfigStartupDelay  
  INTEGER as airIRG3RDUConfigPumpChangeOverInterval  
  INTEGER as airIRG3RDUConfigPowerSource  
  INTEGER as airIRG3RDUConfigOutputSource  
  INTEGER as airIRG3RDUConfigInputNormalState  
  INTEGER as airIRG3RDUConfigOutputNormalState  
  INTEGER as airIRG3RDUConfigByPassValveEnabled  
  INTEGER as airIRG3RDUConfigRefrigerantLeakDetectorEnabled  
  INTEGER as airIRG3RDUConfigCalibrateRefrigerantLeakDetector  
  INTEGER as airIRG3RDUConfigOnReadyStandby  

AirIRG3CMStatusEntry  
SEQUENCE    
  INTEGER as airIRG3CMStatusDeviceIndex  
  DisplayString as airIRG3CMStatusCMID  
  INTEGER as airIRG3CMStatusOperatingMode  
  INTEGER as airIRG3CMStatusUnitType  
  INTEGER as airIRG3CMStatusRackInletTempUS  
  INTEGER as airIRG3CMStatusRackInletTempMetric  
  INTEGER as airIRG3CMStatusReturnAirTempUS  
  INTEGER as airIRG3CMStatusReturnAirTempMetric  
  INTEGER as airIRG3CMStatusLiquidTempUS  
  INTEGER as airIRG3CMStatusLiquidTempMetric  
  INTEGER as airIRG3CMStatusVaporTempUS  
  INTEGER as airIRG3CMStatusVaporTempMetric  
  INTEGER as airIRG3CMStatusEvaporatorTempUS  
  INTEGER as airIRG3CMStatusEvaporatorTempMetric  
  INTEGER as airIRG3CMStatusLiquidInletPressureUS  
  INTEGER as airIRG3CMStatusLiquidInletPressureMetric  
  INTEGER as airIRG3CMStatusVaporOutletPressureUS  
  INTEGER as airIRG3CMStatusVaporOutletPressureMetric  
  INTEGER as airIRG3CMStatusExpansionValvePosition  
  INTEGER as airIRG3CMStatusEPRValvePosition  
  INTEGER as airIRG3CMStatusLocalDisplayOnOffEnabled  
  INTEGER as airIRG3CMStatusAverageFanSpeed  

AirIRG3CMRunHoursEntry  
SEQUENCE    
  INTEGER as airIRG3CMRunHoursDeviceIndex  
  DisplayString as airIRG3CMRunHoursCMID  
  INTEGER as airIRG3CMRunHoursFan1  
  INTEGER as airIRG3CMRunHoursFan2  
  INTEGER as airIRG3CMRunHoursFan3  
  INTEGER as airIRG3CMRunHoursFan4  
  INTEGER as airIRG3CMRunHoursFan5  
  INTEGER as airIRG3CMRunHoursAirFilter  

AirIRG3CMServiceIntervalsEntry  
SEQUENCE    
  INTEGER as airIRG3CMServiceIntervalsDeviceIndex  
  DisplayString as airIRG3CMServiceIntervalsCMID  
  INTEGER as airIRG3CMServiceIntervalsAirFilterInterval  
  INTEGER as airIRG3CMServiceIntervalsAirFilterAlarm  

AirIRG3CMThresholdsEntry  
SEQUENCE    
  INTEGER as airIRG3CMThresholdsDeviceIndex  
  DisplayString as airIRG3CMThresholdsCMID  
  INTEGER as airIRG3CMThresholdsRackInletTempHighUS  
  INTEGER as airIRG3CMThresholdsRackInletTempHighMetric  
  INTEGER as airIRG3CMThresholdsSupplyAirTempHighUS  
  INTEGER as airIRG3CMThresholdsSupplyAirTempHighMetric  
  INTEGER as airIRG3CMThresholdsReturnAirTempHighUS  
  INTEGER as airIRG3CMThresholdsReturnAirTempHighMetric  

AirIRG3CMSetpointsEntry  
SEQUENCE    
  INTEGER as airIRG3CMSetpointsDeviceIndex  

AirIRG3CMConfigEntry  
SEQUENCE    
  INTEGER as airIRG3CMConfigDeviceIndex  
  DisplayString as airIRG3CMConfigCMID  
  INTEGER as airIRG3CMConfigStopOnCoolFail  
  INTEGER as airIRG3CMConfigStartupDelay  
  INTEGER as airIRG3CMConfigRemoteOnStandby  
  INTEGER as airIRG3CMConfigPowerSource  

RARUIdentEntry  
SEQUENCE    
  INTEGER as rARUIdentAruIndex  
  DisplayString as rARUIdentName  

RARUConfigEntry  
SEQUENCE    
  INTEGER as rARUConfigAruIndex  
  DisplayString as rARUConfigAruName  
  INTEGER as rARUConfigAruRemoteSetpoint  
  INTEGER as rARUConfigAruTempOvrdEnableDisable  
  INTEGER as rARUConfigAruTempOvrdSetpoint  
  INTEGER as rARUConfigAruMasterControl  

RARUStatusEntry  
SEQUENCE    
  INTEGER as rARUStatusAruIndex  
  DisplayString as rARUStatusAruName  
  INTEGER as rARUStatusAruRemoteSetpoint  
  INTEGER as rARUStatusAruManualSetpoint  
  INTEGER as rARUStatusAruTemp1  
  INTEGER as rARUStatusAruTemp2  
  INTEGER as rARUStatusAruTemp3  
  INTEGER as rARUStatusAruTempOvrdEnableDisable  
  INTEGER as rARUStatusAruTempOvrdSetpoint  
  DisplayString as rARUStatusAruAlarmState  
  INTEGER as rARUStatusAruCommStatus  
  INTEGER as rARUStatusAruTempOvrdStatus  
  INTEGER as rARUStatusAruMasterControl  
  INTEGER as rARUStatusAruTotalAirflow  

RARUFanStatusEntry  
SEQUENCE    
  INTEGER as rARUFanStatusAruIndex  
  INTEGER as rARUFanStatusNominalFanSpeed  
  INTEGER as rARUFanStatusSelectedFanLevel  
  INTEGER as rARUFanStatusReplacementThreshold  
  INTEGER as rARUFanStatusFanIndex  
  INTEGER as rARUFanStatusFanOperatingStatus  
  INTEGER as rARUFanStatusFanRpmSpeed  
  INTEGER as rARUFanStatusFanFlowRate  
  DisplayString as rARUFanStatusFanInServiceDate  
  INTEGER as rARUFanStatusFanRunhourCounter  
  INTEGER as rARUFanStatusFanRunhourReset  

RARUPowerStatusEntry  
SEQUENCE    
  INTEGER as rARUPowerStatusAruIndex  
  INTEGER as rARUPowerStatusPrimaryAcPresent  
  INTEGER as rARUPowerStatusAuxiliaryAcPresent  
  INTEGER as rARUPowerStatusRedundantAcConfig  

RARUSensorsStatusEntry  
SEQUENCE    
  INTEGER as rARUSensorsStatusAruIndex  
  INTEGER as rARUSensorsStatusSensorNumber  
  INTEGER as rARUSensorsTemperature  

RARUSensorsConfigEntry  
SEQUENCE    
  INTEGER as rARUSensorsConfigAruIndex  
  INTEGER as rARUSensorsConfigSensorNumber  
  DisplayString as rARUSensorsName  
  DisplayString as rARUSensorsLocation  
  INTEGER as rARUSensorsTempMaxThresh  
  INTEGER as rARUSensorsTempHighThresh  
  INTEGER as rARUSensorsTempLowThresh  
  INTEGER as rARUSensorsTempMinThresh  
  INTEGER as rARUSensorsTempThreshHysteresis  
  INTEGER as rARUSensorsTempShortDecRateThreshValue  
  INTEGER as rARUSensorsTempShortDecRateThreshTime  
  INTEGER as rARUSensorsTempShortIncRateThreshValue  
  INTEGER as rARUSensorsTempShortIncRateThreshTime  
  INTEGER as rARUSensorsTempLongDecRateThreshValue  
  INTEGER as rARUSensorsTempLongDecRateThreshTime  
  INTEGER as rARUSensorsTempLongIncRateThreshValue  
  INTEGER as rARUSensorsTempLongIncRateThreshTime  

IsxModularDistInfoEntry  
SEQUENCE    
  INTEGER as isxModularDistInfoSegmentIndex  
  DisplayString as isxModularDistInfoMeterModelNumber  
  DisplayString as isxModularDistInfoMeterSerialNumber  
  DisplayString as isxModularDistInfoMeterDateOfManufacture  
  DisplayString as isxModularDistInfoMeterFirmwareRev  
  DisplayString as isxModularDistInfoMeterHardwareRev  

IsxModularDistModuleInfoEntry  
SEQUENCE    
  INTEGER as isxModularDistModuleInfoModIndex  
  INTEGER as isxModularDistModuleInfoAlarmStatus  
  DisplayString as isxModularDistModuleInfoModelNumber  
  DisplayString as isxModularDistModuleInfoSerialNumber  
  DisplayString as isxModularDistModuleInfoDateOfManufacture  
  INTEGER as isxModularDistModuleInfoNumCables  

IsxModularDistModuleBreakerEntry  
SEQUENCE    
  INTEGER as isxModularDistModuleBreakerModIndex  
  INTEGER as isxModularDistModuleBreakerPhaseIndex  
  INTEGER as isxModularDistModuleBreakerAlarmStatus  
  INTEGER as isxModularDistModuleBreakerRating  
  INTEGER as isxModularDistModuleBreakerPhysicalGroup  
  INTEGER as isxModularDistModuleBreakerCableNum  
  INTEGER as isxModularDistModuleBreakerPosition  
  INTEGER as isxModularDistModuleBreakerPositionAlarms  
  INTEGER as isxModularDistModuleBreakerCurrent  
  INTEGER as isxModularDistModuleBreakerPercent  
  INTEGER as isxModularDistModuleBreakerPower  

IsxModularDistModuleOutputEntry  
SEQUENCE    
  INTEGER as isxModularDistModuleOutputModIndex  
  INTEGER as isxModularDistModuleOutputNumCables  
  INTEGER as isxModularDistModuleOutputCordIndex  
  DisplayString as isxModularDistModuleOutputName  
  DisplayString as isxModularDistModuleOutputLocation  
  INTEGER as isxModularDistModuleOutputStatus  
  INTEGER as isxModularDistModuleOutputAlarmGeneration  
  INTEGER as isxModularDistModuleOutputBreakerMap  
  INTEGER as isxModularDistModuleOutputThresholdMin  
  INTEGER as isxModularDistModuleOutputThresholdLow  
  INTEGER as isxModularDistModuleOutputThresholdHigh  
  INTEGER as isxModularDistModuleOutputThresholdMax  
  INTEGER as isxModularDistModuleOutputAlarmMinEnable  
  INTEGER as isxModularDistModuleOutputAlarmLowEnable  
  INTEGER as isxModularDistModuleOutputAlarmHighEnable  
  INTEGER as isxModularDistModuleOutputAlarmMaxEnable  
  INTEGER as isxModularDistModuleOutputCableLength  
  DisplayString as isxModularDistModuleOutputConnectorType  
  INTEGER as isxModularDistModuleOutputAvailableVoltages  
  INTEGER as isxModularDistModuleOutputTotalPower  
  INTEGER as isxModularDistModuleOutputKwhUsage  
  INTEGER as isxModularDistModuleOutputKwhReset  
  DisplayString as isxModularDistModuleOutputKwhResetDate  

IsxModularDistSubFeedInfoEntry  
SEQUENCE    
  INTEGER as isxModularDistSubFeedInfoSubIndex  
  DisplayString as isxModularDistSubFeedInfoName  
  DisplayString as isxModularDistSubFeedInfoLocation  
  INTEGER as isxModularDistSubFeedInfoBreakerRating  
  INTEGER as isxModularDistSubFeedInfoBreakerPosition  
  INTEGER as isxModularDistSubFeedInfoAlarmStatus  
  INTEGER as isxModularDistSubFeedInfoAlarmGeneration  
  INTEGER as isxModularDistSubFeedInfoThresholdMin  
  INTEGER as isxModularDistSubFeedInfoThresholdLow  
  INTEGER as isxModularDistSubFeedInfoThresholdHigh  
  INTEGER as isxModularDistSubFeedInfoThresholdMax  
  INTEGER as isxModularDistSubFeedInfoAlarmMinEnable  
  INTEGER as isxModularDistSubFeedInfoAlarmLowEnable  
  INTEGER as isxModularDistSubFeedInfoAlarmHighEnable  
  INTEGER as isxModularDistSubFeedInfoAlarmMaxEnable  
  INTEGER as isxModularDistSubFeedInfoBreakerAlarmEnable  
  INTEGER as isxModularDistSubFeedInfoTotalPower  
  INTEGER as isxModularDistSubFeedInfoKwhUsage  
  INTEGER as isxModularDistSubFeedInfoKwhReset  
  DisplayString as isxModularDistSubFeedInfoKwhResetDate  

IsxModularDistSubFeedLoadingEntry  
SEQUENCE    
  INTEGER as isxModularDistSubFeedLoadingSubIndex  
  INTEGER as isxModularDistSubFeedLoadingPhaseIndex  
  INTEGER as isxModularDistSubFeedLoadingAlarmStatus  
  INTEGER as isxModularDistSubFeedLoadingCurrent  
  INTEGER as isxModularDistSubFeedLoadingPercent  
  INTEGER as isxModularDistSubFeedLoadingPower  

IsxModularDistSysVoltageEntry  
SEQUENCE    
  INTEGER as isxModularDistSysVoltagePhaseIndex  
  INTEGER as isxModularDistSysVoltageAlarmStatus  
  INTEGER as isxModularDistSysVoltageLtoN  
  INTEGER as isxModularDistSysVoltageLtoL  

IsxModularDistSysCurrentEntry  
SEQUENCE    
  INTEGER as isxModularDistSysCurrentPhaseIndex  
  INTEGER as isxModularDistSysCurrentAlarmStatus  
  INTEGER as isxModularDistSysCurrentAmps  
  INTEGER as isxModularDistSysCurrentPercent  

IsxModularDistSysPowerEntry  
SEQUENCE    
  INTEGER as isxModularDistSysPowerPhaseIndex  
  INTEGER as isxModularDistSysPowerKw  
  INTEGER as isxModularDistSysPowerKwhPhaseUsage  

UIOSensorStatusEntry  
SEQUENCE    
  INTEGER as uioSensorStatusPortID  
  INTEGER as uioSensorStatusSensorID  
  DisplayString as uioSensorStatusSensorName  
  DisplayString as uioSensorStatusSensorLocation  
  INTEGER as uioSensorStatusTemperatureDegF  
  INTEGER as uioSensorStatusTemperatureDegC  
  INTEGER as uioSensorStatusHumidity  
  INTEGER as uioSensorStatusViolationStatus  
  INTEGER as uioSensorStatusAlarmStatus  
  INTEGER as uioSensorStatusCommStatus  

UIOInputContactStatusEntry  
SEQUENCE    
  INTEGER as uioInputContactStatusPortID  
  INTEGER as uioInputContactStatusContactID  
  DisplayString as uioInputContactStatusContactName  
  DisplayString as uioInputContactStatusContactLocation  
  INTEGER as uioInputContactStatusCurrentState  
  INTEGER as uioInputContactStatusAlarmStatus  
  INTEGER as uioInputContactStatusCommStatus  

UIOOutputRelayStatusEntry  
SEQUENCE    
  INTEGER as uioOutputRelayStatusPortID  
  INTEGER as uioOutputRelayStatusRelayID  
  DisplayString as uioOutputRelayStatusRelayName  
  DisplayString as uioOutputRelayStatusRelayLocation  
  INTEGER as uioOutputRelayStatusCurrentState  
  INTEGER as uioOutputRelayStatusAlarmStatus  
  INTEGER as uioOutputRelayStatusCommStatus