
| SNMPv2-SMI | SNMPv2-TC | SNMPv2-CONF |
| HOST-RESOURCES-MIB |
| MODULE-IDENTITY | OBJECT-TYPE | Counter32 |
| Integer32 | TimeTicks | NOTIFICATION-TYPE |
| OBJECT-IDENTITY | mib-2 | TEXTUAL-CONVENTION |
| DisplayString | MODULE-COMPLIANCE | OBJECT-GROUP |
| hrDeviceIndex | hrStorageIndex |
| printmib | 1.3.6.1.2.1.43 | ||
| The MIB module for management of printers. | |||
| MODULE-IDENTITY | |||
| prtMIBConformance | 1.3.6.1.2.1.43.2 | ||
| OBJECT IDENTIFIER | |||
| prtMIBCompliance | 1.3.6.1.2.1.43.2.1 | ||
| The compliance statement for agents that implement the printer MIB. | |||
| MODULE-COMPLIANCE | |||
| prtMIBGroups | 1.3.6.1.2.1.43.2.2 | ||
| OBJECT IDENTIFIER | |||
| prtGeneralGroup | 1.3.6.1.2.1.43.2.2.1 | ||
| The general printer group. | |||
| OBJECT-GROUP | |||
| prtResponsiblePartyGroup | 1.3.6.1.2.1.43.2.2.2 | ||
| The responsible party group contains contact information for humans responsible for the printer. | |||
| OBJECT-GROUP | |||
| prtInputGroup | 1.3.6.1.2.1.43.2.2.3 | ||
| The input group. | |||
| OBJECT-GROUP | |||
| prtExtendedInputGroup | 1.3.6.1.2.1.43.2.2.4 | ||
| The extended input group. | |||
| OBJECT-GROUP | |||
| prtInputMediaGroup | 1.3.6.1.2.1.43.2.2.5 | ||
| The input media group. | |||
| OBJECT-GROUP | |||
| prtOutputGroup | 1.3.6.1.2.1.43.2.2.6 | ||
| The output group. | |||
| OBJECT-GROUP | |||
| prtExtendedOutputGroup | 1.3.6.1.2.1.43.2.2.7 | ||
| The extended output group. | |||
| OBJECT-GROUP | |||
| prtOutputDimensionsGroup | 1.3.6.1.2.1.43.2.2.8 | ||
| The output dimensions group | |||
| OBJECT-GROUP | |||
| prtOutputFeaturesGroup | 1.3.6.1.2.1.43.2.2.9 | ||
| The output features group. | |||
| OBJECT-GROUP | |||
| prtMarkerGroup | 1.3.6.1.2.1.43.2.2.10 | ||
| The marker group. | |||
| OBJECT-GROUP | |||
| prtMarkerSuppliesGroup | 1.3.6.1.2.1.43.2.2.11 | ||
| The marker supplies group. | |||
| OBJECT-GROUP | |||
| prtMarkerColorantGroup | 1.3.6.1.2.1.43.2.2.12 | ||
| The marker colorant group. | |||
| OBJECT-GROUP | |||
| prtMediaPathGroup | 1.3.6.1.2.1.43.2.2.13 | ||
| The media path group. | |||
| OBJECT-GROUP | |||
| prtChannelGroup | 1.3.6.1.2.1.43.2.2.14 | ||
| The channel group. | |||
| OBJECT-GROUP | |||
| prtInterpreterGroup | 1.3.6.1.2.1.43.2.2.15 | ||
| The interpreter group. | |||
| OBJECT-GROUP | |||
| prtConsoleGroup | 1.3.6.1.2.1.43.2.2.16 | ||
| The console group. | |||
| OBJECT-GROUP | |||
| prtAlertTableGroup | 1.3.6.1.2.1.43.2.2.17 | ||
| The alert table group. | |||
| OBJECT-GROUP | |||
| prtAuxiliarySheetGroup | 1.3.6.1.2.1.43.2.2.19 | ||
| The auxiliary sheet group. | |||
| OBJECT-GROUP | |||
| prtInputSwitchingGroup | 1.3.6.1.2.1.43.2.2.20 | ||
| The input switching group. | |||
| OBJECT-GROUP | |||
| prtGeneral | 1.3.6.1.2.1.43.5 | ||
| OBJECT IDENTIFIER | |||
| prtGeneralTable | 1.3.6.1.2.1.43.5.1 | ||
| A table of general information per printer. Objects in this table are defined in various places in the MIB, nearby the groups to which they apply. They are all defined here to minimize the number of tables that would otherwise need to exist. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtGeneralEntry | |||
| prtGeneralEntry | 1.3.6.1.2.1.43.5.1.1 | ||
| An entry exists in this table for each device entry in the host resources MIB device table with a device type of 'printer' | |||
| OBJECT-TYPE | |||
| PrtGeneralEntry | |||
| prtGeneralConfigChanges | 1.3.6.1.2.1.43.5.1.1.1 | ||
| Counts configuration changes within the printer. A configuration change is defined to be an action that results in a change to any MIB object other than those that reflect status or level, or those that act as counters or gauges. In addition, any action that results in a row being added or deleted from any table in the Printer MIB is considered a configuration change. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub-units within the printer. This object should be incremented whenever the agent wishes to notify management applications that any cached configuration information for this device is to be considered 'stale'. At this point, the management application should flush any configuration information cached about this device and fetch new configuration information. The following are examples of actions that would cause the prtGeneralConfigChanges object to be incremented: - Adding an output bin - Changing the media in a sensing input tray - Changing the value of prtInputMediaType Note that the prtGeneralConfigChanges counter would not be incremented when an input tray is removed, or the level of an input device changes. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| prtGeneralCurrentLocalization | 1.3.6.1.2.1.43.5.1.1.2 | ||
| The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or to any object that is not explicitly identified as being localized according to prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtGeneralReset | 1.3.6.1.2.1.43.5.1.1.3 | ||
| Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value 'notResetting(3)', and a SET of the value 'notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values 'notResetting' and 'resetToNVRAM'. | |||
| OBJECT-TYPE | |||
| PrtGeneralResetTC | |||
| prtGeneralCurrentOperator | 1.3.6.1.2.1.43.5.1.1.4 | ||
| The name of the person who is responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number. As a convention to facilitate automatic notification of the operator by the agent or the network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, spaces and parentheses, which shall be ignored. Phone numbers may also include ASCII comma characters(hex 2C) that are used to indicate a two- second pause during the dialing sequence. If either the phone, fax, or email information is not available, then a line should not be included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..127) | ||
| prtGeneralServicePerson | 1.3.6.1.2.1.43.5.1.1.5 | ||
| The name of the person responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number. As a convention to facilitate automatic notification of the service person by the agent or a network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, spaces and parentheses, which shall be ignored. Phone numbers can also include one or more ASCII comma characters(hex 2C) to indicate a two-second pause during the dialing sequence. If either the phone, fax, or email information is not available, then a line should not included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..127) | ||
| prtInputDefaultIndex | 1.3.6.1.2.1.43.5.1.1.6 | ||
| The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. This value shall be -1 if there is no default input subunit specified for the printer as a whole. In this case, the actual default input subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputDefaultIndex | 1.3.6.1.2.1.43.5.1.1.7 | ||
| The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. This value shall be -1 if there is no default output subunit specified for the printer as a whole. In this case, the actual default output subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerDefaultIndex | 1.3.6.1.2.1.43.5.1.1.8 | ||
| The value of prtMarkerIndex corresponding to the default marker sub-unit; that is, this object selects the default marker. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtMediaPathDefaultIndex | 1.3.6.1.2.1.43.5.1.1.9 | ||
| The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtConsoleLocalization | 1.3.6.1.2.1.43.5.1.1.10 | ||
| The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management operations. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtConsoleNumberOfDisplayLines | 1.3.6.1.2.1.43.5.1.1.11 | ||
| The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtConsoleNumberOfDisplayChars | 1.3.6.1.2.1.43.5.1.1.12 | ||
| The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtConsoleDisable | 1.3.6.1.2.1.43.5.1.1.13 | ||
| If the object prtConsoleDisable has value 'operatorConsoleDisabled' then input is not accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabled' then input is accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabledLevel1', 'operatorConsoleEnabledLevel2' or 'operatorConsoleEnabledLevel3' then limited input is accepted from the operator console; the limitations are product specific, however, the limitations are generally less restrictive for operatorConsoleEnabledLevel1 than for operatorConsoleEnabledLeve2, which is less restrictive than operatorConsoleEnabledLevel3. The value of the prtConsoleDisable object is a type-2 enumeration. | |||
| OBJECT-TYPE | |||
| INTEGER | operatorConsoleEnabled(3), operatorConsoleDisabled(4), operatorConsoleEnabledLevel1(5), operatorConsoleEnabledLevel2(6), operatorConsoleEnabledLevel3(7) | ||
| prtAuxiliarySheetStartupPage | 1.3.6.1.2.1.43.5.1.1.14 | ||
| Used to enable or disable printing a startup page. If enabled, a startup page will be printed shortly after power-up, when the device is ready. Typical startup pages include test patterns and/or printer configuration information. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtAuxiliarySheetBannerPage | 1.3.6.1.2.1.43.5.1.1.15 | ||
| Used to enable or disable printing banner pages at the beginning of jobs. This is a master switch which applies to all jobs, regardless of interpreter. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtGeneralPrinterName | 1.3.6.1.2.1.43.5.1.1.16 | ||
| An administrator-specified name for this printer. Depending upon implementation of this printer, the value of this object may or may not be same as the value for the MIB-II 'SysName' object. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..127) | ||
| prtGeneralSerialNumber | 1.3.6.1.2.1.43.5.1.1.17 | ||
| A recorded serial number for this device that indexes some type device catalog or inventory. This value is usually set by the device manufacturer but the MIB supports the option of writing for this object for site- specific administration of device inventory or tracking. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtAlertCriticalEvents | 1.3.6.1.2.1.43.5.1.1.18 | ||
| A running counter of the number of critical alert events that have been recorded in the alert table. The value of this object is RESET in the event of a power cycle operation (i.e., the value is not persistent. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| prtAlertAllEvents | 1.3.6.1.2.1.43.5.1.1.19 | ||
| A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| prtStorageRefTable | 1.3.6.1.2.1.43.5.2 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtStorageRefEntry | |||
| prtStorageRefEntry | 1.3.6.1.2.1.43.5.2.1 | ||
| This table will have an entry for each entry in the Host Resources MIB storage table that represents storage associated with a printer managed by this agent. | |||
| OBJECT-TYPE | |||
| PrtStorageRefEntry | |||
| prtStorageRefSeqNumber | 1.3.6.1.2.1.43.5.2.1.1 | ||
| This value will be unique amongst all entries with a common value of hrStorageIndex. This object allows a storage entry to point to the multiple printer devices with which it is associated. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtStorageRefIndex | 1.3.6.1.2.1.43.5.2.1.2 | ||
| The value of the hrDeviceIndex of the printer device that this storageEntry is associated with. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtDeviceRefTable | 1.3.6.1.2.1.43.5.3 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtDeviceRefEntry | |||
| prtDeviceRefEntry | 1.3.6.1.2.1.43.5.3.1 | ||
| This table will have an entry for each entry in the Host Resources MIB device table that represents a device associated with a printer managed by this agent. | |||
| OBJECT-TYPE | |||
| PrtDeviceRefEntry | |||
| prtDeviceRefSeqNumber | 1.3.6.1.2.1.43.5.3.1.1 | ||
| This value will be unique amongst all entries with a common value of hrDeviceIndex. This object allows a device entry to point to the multiple printer devices with which it is associated. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtDeviceRefIndex | 1.3.6.1.2.1.43.5.3.1.2 | ||
| The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtCover | 1.3.6.1.2.1.43.6 | ||
| OBJECT IDENTIFIER | |||
| prtCoverTable | 1.3.6.1.2.1.43.6.1 | ||
| A table of the covers and interlocks of the printer. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtCoverEntry | |||
| prtCoverEntry | 1.3.6.1.2.1.43.6.1.1 | ||
| Information about a cover or interlock. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtCoverEntry | |||
| prtCoverIndex | 1.3.6.1.2.1.43.6.1.1.1 | ||
| A unique value used by the printer to identify this Cover sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new cover sub-units to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtCoverDescription | 1.3.6.1.2.1.43.6.1.1.2 | ||
| The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtCoverStatus | 1.3.6.1.2.1.43.6.1.1.3 | ||
| The status of this cover sub-unit. | |||
| OBJECT-TYPE | |||
| PrtCoverStatusTC | |||
| prtLocalization | 1.3.6.1.2.1.43.7 | ||
| OBJECT IDENTIFIER | |||
| prtLocalizationTable | 1.3.6.1.2.1.43.7.1 | ||
| The available localizations in this printer. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtLocalizationEntry | |||
| prtLocalizationEntry | 1.3.6.1.2.1.43.7.1.1 | ||
| A description of a localization. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtLocalizationEntry | |||
| prtLocalizationIndex | 1.3.6.1.2.1.43.7.1.1.1 | ||
| A unique value used by the printer to identify this localization entry. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new localization data to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtLocalizationLanguage | 1.3.6.1.2.1.43.7.1.1.2 | ||
| A two character language code from ISO 639. Examples en, gb, ca, fr, de. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..2) | ||
| prtLocalizationCountry | 1.3.6.1.2.1.43.7.1.1.3 | ||
| A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ... | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..2) | ||
| prtLocalizationCharacterSet | 1.3.6.1.2.1.43.7.1.1.4 | ||
| The coded character set used for this localization. | |||
| OBJECT-TYPE | |||
| CodedCharSet | |||
| prtInput | 1.3.6.1.2.1.43.8 | ||
| OBJECT IDENTIFIER | |||
| prtInputTable | 1.3.6.1.2.1.43.8.2 | ||
| A table of the devices capable of providing media for input to the printing process. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtInputEntry | |||
| prtInputEntry | 1.3.6.1.2.1.43.8.2.1 | ||
| Attributes of a device capable of providing media for input to the printing process. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtInputEntry | |||
| prtInputIndex | 1.3.6.1.2.1.43.8.2.1.1 | ||
| A unique value used by the printer to identify this input sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of n input sub-units to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtInputType | 1.3.6.1.2.1.43.8.2.1.2 | ||
| The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice. | |||
| OBJECT-TYPE | |||
| PrtInputTypeTC | |||
| prtInputDimUnit | 1.3.6.1.2.1.43.8.2.1.3 | ||
| The unit of measurement for use calculating and relaying dimensional values for this input sub-unit. | |||
| OBJECT-TYPE | |||
| PrtMediaUnitTC | |||
| prtInputMediaDimFeedDirDeclared | 1.3.6.1.2.1.43.8.2.1.4 | ||
| This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputMediaDimXFeedDirDeclared | 1.3.6.1.2.1.43.8.2.1.5 | ||
| This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with this sub- unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub- unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub- unit places no restriction on this parameter. The value (-2) indicates unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputMediaDimFeedDirChosen | 1.3.6.1.2.1.43.8.2.1.6 | ||
| The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken relative to the feed direction associated with that sub-unit and are in input sub-unit dimensional units (MediaUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputMediaDimXFeedDirChosen | 1.3.6.1.2.1.43.8.2.1.7 | ||
| The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (MediaUnit). If the printer supports the declare dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputCapacityUnit | 1.3.6.1.2.1.43.8.2.1.8 | ||
| The unit of measurement for use in calculating and relaying capacity values for this input sub-unit. | |||
| OBJECT-TYPE | |||
| PrtCapacityUnitTC | |||
| prtInputMaxCapacity | 1.3.6.1.2.1.43.8.2.1.9 | ||
| The maximum capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputCurrentLevel | 1.3.6.1.2.1.43.8.2.1.10 | ||
| The current capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that at least one unit remains. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputStatus | 1.3.6.1.2.1.43.8.2.1.11 | ||
| The current status of this input sub-unit. | |||
| OBJECT-TYPE | |||
| PrtSubUnitStatusTC | |||
| prtInputMediaName | 1.3.6.1.2.1.43.8.2.1.12 | ||
| A description of the media contained in this input sub- unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media attributes (e.g. prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputMediaWeight, prtInputMediaType). An example would be 'legal tender bond paper'. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputName | 1.3.6.1.2.1.43.8.2.1.13 | ||
| The name assigned to this input sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputVendorName | 1.3.6.1.2.1.43.8.2.1.14 | ||
| The vendor name of this input sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputModel | 1.3.6.1.2.1.43.8.2.1.15 | ||
| The model name of this input sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputVersion | 1.3.6.1.2.1.43.8.2.1.16 | ||
| The version of this input sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputSerialNumber | 1.3.6.1.2.1.43.8.2.1.17 | ||
| The serial number assigned to this input sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputDescription | 1.3.6.1.2.1.43.8.2.1.18 | ||
| A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtInputSecurity | 1.3.6.1.2.1.43.8.2.1.19 | ||
| Indicates if this input sub-unit has some security associated with it. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtInputMediaWeight | 1.3.6.1.2.1.43.8.2.1.20 | ||
| The weight of the medium associated with this input sub-unit in grams / per meter squared. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputMediaType | 1.3.6.1.2.1.43.8.2.1.21 | ||
| The name of the type of medium associated with this input sub-unit. This name need not be processed by the printer; it might simply be displayed to an operator. The standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are: stationery Separately cut sheets of an opaque material transparency Separately cut sheets of a transparent material envelope Envelopes that can be used for conventional mailing purposes envelope-plain Envelopes that are not preprinted and have no windows envelope-window Envelopes that have windows for addressing purposes continuous-long Continuously connected sheets of an opaque material connected along the long edge continuous-short Continuously connected sheets of an opaque material connected along the short edge tab-stock Media with tabs multi-part-form Form medium composed of multiple layers not pre-attached to one another; each sheet may be drawn separately from an input source labels Label stock multi-layer Form medium composed of multiple layers which are pre-attached to one another; e.g., for use with impact printers. Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputMediaColor | 1.3.6.1.2.1.43.8.2.1.22 | ||
| The name of the color of the medium associated with this input sub-unit using standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white pink yellow buff goldenrod blue green transparent Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtInputMediaFormParts | 1.3.6.1.2.1.43.8.2.1.23 | ||
| The number of parts associated with the medium associated with this input sub-unit if the medium is a multi-part form. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputMediaLoadTimeout | 1.3.6.1.2.1.43.8.2.1.24 | ||
| When the printer is not able to print due to a subunit being empty or the requested media must be manually loaded, the printer will wait for the duration (in seconds) specified by this object. Upon expiration of the time-out, the printer will take the action specified by prtInputNextIndex. The event which causes the printer to enter the waiting state is product specific. If the printer is not waiting for manually fed media, it may switch from an empty subunit to a different subunit without waiting for the time-out to expire. A value of (-1) implies 'other' or 'infinite' which translates to 'wait forever'. The action which causes printing to continue is product specific. A value of (- 2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInputNextIndex | 1.3.6.1.2.1.43.8.2.1.25 | ||
| The value of prtInputIndex corresponding to the input subunit which will be used when this input subunit is emptied and the time-out specified by prtInputMediaLoadTimeout expires. A value of zero(0) indicates that auto input switching will not occur when this input subunit is emptied. If the time-out specified by prtInputLoadMediaTimeout expires and this value is zero(0), the job will be aborted. A value of (-1) means other. The value (-2) means 'unknown' and specifically indicates that an implementation specific method will determine the next input subunit to use at the time this subunit is emptied and the time-out expires. The value(- 3) means input switching is not supported for this subunit. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutput | 1.3.6.1.2.1.43.9 | ||
| OBJECT IDENTIFIER | |||
| prtOutputTable | 1.3.6.1.2.1.43.9.2 | ||
| A table of the devices capable of receiving media delivered from the printing process. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtOutputEntry | |||
| prtOutputEntry | 1.3.6.1.2.1.43.9.2.1 | ||
| Attributes of a device capable of receiving media delivered from the printing process. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtOutputEntry | |||
| prtOutputIndex | 1.3.6.1.2.1.43.9.2.1.1 | ||
| A unique value used by this printer to identify this output sub-unit. Although these values may change due to a major reconfiguration of the sub-unit (e.g. the addition of new output devices to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtOutputType | 1.3.6.1.2.1.43.9.2.1.2 | ||
| The type of technology supported by this output sub- unit. | |||
| OBJECT-TYPE | |||
| PrtOutputTypeTC | |||
| prtOutputCapacityUnit | 1.3.6.1.2.1.43.9.2.1.3 | ||
| The unit of measurement for use in calculating and relaying capacity values for this output sub-unit. | |||
| OBJECT-TYPE | |||
| PrtCapacityUnitTC | |||
| prtOutputMaxCapacity | 1.3.6.1.2.1.43.9.2.1.4 | ||
| The maximum capacity of this output sub-unit in output sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputRemainingCapacity | 1.3.6.1.2.1.43.9.2.1.5 | ||
| The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (PrtCapacityUnitTC)of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (- 3) means that the printer knows that there remains capacity for at least one unit. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputStatus | 1.3.6.1.2.1.43.9.2.1.6 | ||
| The current status of this output sub-unit. | |||
| OBJECT-TYPE | |||
| PrtSubUnitStatusTC | |||
| prtOutputName | 1.3.6.1.2.1.43.9.2.1.7 | ||
| The name assigned to this output sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtOutputVendorName | 1.3.6.1.2.1.43.9.2.1.8 | ||
| The vendor name of this output sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtOutputModel | 1.3.6.1.2.1.43.9.2.1.9 | ||
| The model name assigned to this output sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtOutputVersion | 1.3.6.1.2.1.43.9.2.1.10 | ||
| The version of this output sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtOutputSerialNumber | 1.3.6.1.2.1.43.9.2.1.11 | ||
| The serial number assigned to this output sub-unit. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtOutputDescription | 1.3.6.1.2.1.43.9.2.1.12 | ||
| A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtOutputSecurity | 1.3.6.1.2.1.43.9.2.1.13 | ||
| Indicates if this output sub-unit has some security associated with it and if that security is enabled or not. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtOutputDimUnit | 1.3.6.1.2.1.43.9.2.1.14 | ||
| The unit of measurement for use in calculating and relaying dimensional values for this output sub-unit. | |||
| OBJECT-TYPE | |||
| PrtMediaUnitTC | |||
| prtOutputMaxDimFeedDir | 1.3.6.1.2.1.43.9.2.1.15 | ||
| The maximum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (MediaUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputMaxDimXFeedDir | 1.3.6.1.2.1.43.9.2.1.16 | ||
| The maximum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (MediaUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputMinDimFeedDir | 1.3.6.1.2.1.43.9.2.1.17 | ||
| The minimum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputMinDimXFeedDir | 1.3.6.1.2.1.43.9.2.1.18 | ||
| The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtOutputStackingOrder | 1.3.6.1.2.1.43.9.2.1.19 | ||
| The current state of the stacking order for the associated output sub-unit. 'FirstToLast' means that as pages are output the front of the next page is placed against the back of the previous page. 'LasttoFirst' means that as pages are output the back of the next page is placed against the front of the previous page. | |||
| OBJECT-TYPE | |||
| PrtOutputStackingOrderTC | |||
| prtOutputPageDeliveryOrientation | 1.3.6.1.2.1.43.9.2.1.20 | ||
| The reading surface that will be 'up' when pages are delivered to the associated output sub-unit. Values are faceUp and faceDown. (Note: interpretation of these values is in general context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user). | |||
| OBJECT-TYPE | |||
| PrtOutputPageDeliveryOrientationTC | |||
| prtOutputBursting | 1.3.6.1.2.1.43.9.2.1.21 | ||
| This object indicates that the outputting sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous media is separated into individual sheets, typically by bursting along pre-formed perforations. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtOutputDecollating | 1.3.6.1.2.1.43.9.2.1.22 | ||
| This object indicates that the output supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individual parts within a multi-part form are separated and sorted into separate stacks for each part. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtOutputPageCollated | 1.3.6.1.2.1.43.9.2.1.23 | ||
| This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled. See glossary for definition of how this document defines collation. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtOutputOffsetStacking | 1.3.6.1.2.1.43.9.2.1.24 | ||
| This object indicates that the output supports offset stacking, and if so, whether the feature is enabled. See glossary for how Offset Stacking is defined by this document. | |||
| OBJECT-TYPE | |||
| PresentOnOff | |||
| prtMarker | 1.3.6.1.2.1.43.10 | ||
| OBJECT IDENTIFIER | |||
| prtMarkerTable | 1.3.6.1.2.1.43.10.2 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtMarkerEntry | |||
| prtMarkerEntry | 1.3.6.1.2.1.43.10.2.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtMarkerEntry | |||
| prtMarkerIndex | 1.3.6.1.2.1.43.10.2.1.1 | ||
| A unique value used by the printer to identify this marking SubUnit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marking sub-units to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtMarkerMarkTech | 1.3.6.1.2.1.43.10.2.1.2 | ||
| The type of marking technology used for this marking sub-unit. | |||
| OBJECT-TYPE | |||
| PrtMarkerMarkTechTC | |||
| prtMarkerCounterUnit | 1.3.6.1.2.1.43.10.2.1.3 | ||
| The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets. | |||
| OBJECT-TYPE | |||
| PrtMarkerCounterUnitTC | |||
| prtMarkerLifeCount | 1.3.6.1.2.1.43.10.2.1.4 | ||
| The count of the number of units of measure counted during the life of printer using units of measure as specified by prtMarkerCounterUnit. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| prtMarkerPowerOnCount | 1.3.6.1.2.1.43.10.2.1.5 | ||
| The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by prtMarkerCounterUnit. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| prtMarkerProcessColorants | 1.3.6.1.2.1.43.10.2.1.6 | ||
| The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and prtMarkerSpotColorants cannot both be 0. The value of prtMarkerProcessColorants must be 0 or greater. | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtMarkerSpotColorants | 1.3.6.1.2.1.43.10.2.1.7 | ||
| The number of spot colors supported by this marker. The value of this object and prtMarkerProcessColorants cannot both be 0. Must be 0 or greater. | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtMarkerAddressabilityUnit | 1.3.6.1.2.1.43.10.2.1.8 | ||
| The unit of measure of distances, as applied to the marker's resolution. | |||
| OBJECT-TYPE | |||
| INTEGER | tenThousandthsOfInches(3), micrometers(4) | ||
| prtMarkerAddressabilityFeedDir | 1.3.6.1.2.1.43.10.2.1.9 | ||
| The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerAddressabilityXFeedDir | 1.3.6.1.2.1.43.10.2.1.10 | ||
| The maximum number of addressable marking positions in the cross feed direction in 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (- 1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerNorthMargin | 1.3.6.1.2.1.43.10.2.1.11 | ||
| The margin, in units identified by prtMarkerAddressabilityUnit, from the leading edge of the medium as the medium flows through the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerSouthMargin | 1.3.6.1.2.1.43.10.2.1.12 | ||
| The margin from the South edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerWestMargin | 1.3.6.1.2.1.43.10.2.1.13 | ||
| The margin from the West edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerEastMargin | 1.3.6.1.2.1.43.10.2.1.14 | ||
| The margin from the East edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerStatus | 1.3.6.1.2.1.43.10.2.1.15 | ||
| The current status of this marker sub-unit. | |||
| OBJECT-TYPE | |||
| PrtSubUnitStatusTC | |||
| prtMarkerSupplies | 1.3.6.1.2.1.43.11 | ||
| OBJECT IDENTIFIER | |||
| prtMarkerSuppliesTable | 1.3.6.1.2.1.43.11.1 | ||
| A table of the marker supplies available on this printer. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtMarkerSuppliesEntry | |||
| prtMarkerSuppliesEntry | 1.3.6.1.2.1.43.11.1.1 | ||
| Attributes of a marker supply. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtMarkerSuppliesEntry | |||
| prtMarkerSuppliesIndex | 1.3.6.1.2.1.43.11.1.1.1 | ||
| A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across successive power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtMarkerSuppliesMarkerIndex | 1.3.6.1.2.1.43.11.1.1.2 | ||
| The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated. | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtMarkerSuppliesColorantIndex | 1.3.6.1.2.1.43.11.1.1.3 | ||
| The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table or if this supply does not depend on a single specified colorant. | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtMarkerSuppliesClass | 1.3.6.1.2.1.43.11.1.1.4 | ||
| Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled. | |||
| OBJECT-TYPE | |||
| PrtMarkerSuppliesClassTC | |||
| prtMarkerSuppliesType | 1.3.6.1.2.1.43.11.1.1.5 | ||
| The type of this supply. | |||
| OBJECT-TYPE | |||
| PrtMarkerSuppliesTypeTC | |||
| prtMarkerSuppliesDescription | 1.3.6.1.2.1.43.11.1.1.6 | ||
| The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtMarkerSuppliesSupplyUnit | 1.3.6.1.2.1.43.11.1.1.7 | ||
| Unit of measure of this marker supply container/receptacle. | |||
| OBJECT-TYPE | |||
| PrtMarkerSuppliesSupplyUnitTC | |||
| prtMarkerSuppliesMaxCapacity | 1.3.6.1.2.1.43.11.1.1.8 | ||
| The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerSuppliesLevel | 1.3.6.1.2.1.43.11.1.1.9 | ||
| The current level if this supply is a container; remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read- only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (- 1) means other and specifically indicates that the sub- unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMarkerColorant | 1.3.6.1.2.1.43.12 | ||
| OBJECT IDENTIFIER | |||
| prtMarkerColorantTable | 1.3.6.1.2.1.43.12.1 | ||
| A table of all of the colorants available on the printer. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtMarkerColorantEntry | |||
| prtMarkerColorantEntry | 1.3.6.1.2.1.43.12.1.1 | ||
| Attributes of a colorant available on the printer. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtMarkerColorantEntry | |||
| prtMarkerColorantIndex | 1.3.6.1.2.1.43.12.1.1.1 | ||
| A unique value used by the printer to identify this colorant. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new colorants to the printer). | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtMarkerColorantMarkerIndex | 1.3.6.1.2.1.43.12.1.1.2 | ||
| The value of prtMarkerIndex corresponding to the marker sub-unit with which this colorant entry is associated. | |||
| OBJECT-TYPE | |||
| Integer32 | 0..65535 | ||
| prtMarkerColorantRole | 1.3.6.1.2.1.43.12.1.1.3 | ||
| The role played by this colorant. | |||
| OBJECT-TYPE | |||
| PrtMarkerColorantRoleTC | |||
| prtMarkerColorantValue | 1.3.6.1.2.1.43.12.1.1.4 | ||
| The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white red green blue cyan magenta yellow black Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtMarkerColorantTonality | 1.3.6.1.2.1.43.12.1.1.5 | ||
| The distinct levels of tonality realizable by a marking sub-unit when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least 2. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPath | 1.3.6.1.2.1.43.13 | ||
| OBJECT IDENTIFIER | |||
| prtMediaPathTable | 1.3.6.1.2.1.43.13.4 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtMediaPathEntry | |||
| prtMediaPathEntry | 1.3.6.1.2.1.43.13.4.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtMediaPathEntry | |||
| prtMediaPathIndex | 1.3.6.1.2.1.43.13.4.1.1 | ||
| A unique value used by the printer to identify this media path. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new media paths to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtMediaPathMaxSpeedPrintUnit | 1.3.6.1.2.1.43.13.4.1.2 | ||
| The unit of measure used in specifying the speed of all media paths in the printer. | |||
| OBJECT-TYPE | |||
| PrtMediaPathMaxSpeedPrintUnitTC | |||
| prtMediaPathMediaSizeUnit | 1.3.6.1.2.1.43.13.4.1.3 | ||
| The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer. | |||
| OBJECT-TYPE | |||
| PrtMediaUnitTC | |||
| prtMediaPathMaxSpeed | 1.3.6.1.2.1.43.13.4.1.4 | ||
| The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPathMaxMediaFeedDir | 1.3.6.1.2.1.43.13.4.1.5 | ||
| The maximum physical media size in the feed direction of this media path expressed in units of measure specified by PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited' a value of (-2) implies 'unknown' | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPathMaxMediaXFeedDir | 1.3.6.1.2.1.43.13.4.1.6 | ||
| The maximum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPathMinMediaFeedDir | 1.3.6.1.2.1.43.13.4.1.7 | ||
| The minimum physical media size in the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPathMinMediaXFeedDir | 1.3.6.1.2.1.43.13.4.1.8 | ||
| The minimum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtMediaPathType | 1.3.6.1.2.1.43.13.4.1.9 | ||
| The type of the media path for this media path. | |||
| OBJECT-TYPE | |||
| PrtMediaPathTypeTC | |||
| prtMediaPathDescription | 1.3.6.1.2.1.43.13.4.1.10 | ||
| The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtMediaPathStatus | 1.3.6.1.2.1.43.13.4.1.11 | ||
| The current status of this media path. | |||
| OBJECT-TYPE | |||
| PrtSubUnitStatusTC | |||
| prtChannel | 1.3.6.1.2.1.43.14 | ||
| OBJECT IDENTIFIER | |||
| prtChannelTable | 1.3.6.1.2.1.43.14.1 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtChannelEntry | |||
| prtChannelEntry | 1.3.6.1.2.1.43.14.1.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtChannelEntry | |||
| prtChannelIndex | 1.3.6.1.2.1.43.14.1.1.1 | ||
| A unique value used by the printer to identify this data channel. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new data channels to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtChannelType | 1.3.6.1.2.1.43.14.1.1.2 | ||
| The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with additional details about that channel. | |||
| OBJECT-TYPE | |||
| PrtChannelTypeTC | |||
| prtChannelProtocolVersion | 1.3.6.1.2.1.43.14.1.1.3 | ||
| The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..63) | ||
| prtChannelCurrentJobCntlLangIndex | 1.3.6.1.2.1.43.14.1.1.4 | ||
| The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control functions, such as querying or changing environment variables and identifying job boundaries (e.g. PJL, PostScript, NPAP). A value of zero indicates that there is no current Job Control Language Interpreter for this channel | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtChannelDefaultPageDescLangIndex | 1.3.6.1.2.1.43.14.1.1.5 | ||
| The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Description Language interpreter to be used for the print data unless the Control Language is used to select a specific interpreter (e.g., PCL, PostScript Language, auto- sense). A value of zero indicates that there is no default page description language interpreter for this channel. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtChannelState | 1.3.6.1.2.1.43.14.1.1.6 | ||
| The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not. | |||
| OBJECT-TYPE | |||
| PrtChannelStateTC | |||
| prtChannelIfIndex | 1.3.6.1.2.1.43.14.1.1.7 | ||
| The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is relevant, this is the index of the row representing the topmost layer in the interface hierarchy. A value of zero indicates that no interface is associated with this channel. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtChannelStatus | 1.3.6.1.2.1.43.14.1.1.8 | ||
| The current status of the channel. | |||
| OBJECT-TYPE | |||
| PrtSubUnitStatusTC | |||
| prtChannelInformation | 1.3.6.1.2.1.43.14.1.1.9 | ||
| Auxiliary information to allow a printing application to use the channel for data submission to the printer. An application capable of using a specific PrtChannelType should be able to use the combined information from the prtChannelInformation and other channel and interface group objects to 'bootstrap' its use of the channel. prtChannelInformation is not intended to provide a general channel description, nor to provide information that is available once the channel is in use. The encoding and interpretation of the prtChannelInformation object is specific to channel type. The description of each PrtChannelType enum value for which prtChannelInformation is defined specifies the appropriate encoding and interpretation, including interaction with other objects. For channel types that do not specify a prtChannelInformation value, its value shall be null (0 length). When a new PrtChannelType enumeration value is registered, its accompanying description must specify the encoding and interpretation of the prtChannelInformation value for the channel type. prtChannelInformation semantics for an existing PrtChannelType may be added or amended in the same manner as described in section 2.4.1 for type 2 enumeration values. The prtChannelInformation specifies values for a collection of channel attributes, represented as text according to the following rules: 1. The prtChannelInformation is not affected by localization. 2. The prtChannelInformation is a list of entries representing the attribute values. Each entry consists of the following items, in order: a. a keyword, composed of alphabetic characters (A-Z, a-z) represented by their NVT ASCII [NVT ASCII] codes, that identifies a channel attribute, b. the NVT ASCII code for an Equals Sign (=) (code 61) to delimit the keyword, c. a data value encoded using rules specific to the PrtChannelType to with the prtChannelInformation applies which must in no case allow an octet with value 10 (the NVT ASCII Line Feed code), d. the NVT ASCII code for a Line Feed character (code 10) to delimit the data value. No other octets shall be present. Keywords are case-sensitive. Conventionally, keywords are capitalized (including each word of a multi-word keyword) and since they occupy space in the prtChannelInformation, they are kept short. 3. If a channel attribute has multiple values, it is represented by multiple entries with the same keyword, each specifying one value. Otherwise, there shall be at most one entry for each attribute. 4. By default, entries may appear in any order. If there are ordering constraints for particular entries, these must be specified in their definitions. 5. The prtChannelInformation value by default consists of text represented by NVT ASCII graphics character codes. However, other representations may be specified: a. In cases where the prtChannelInformation value contains information not normally coded in textual form, whatever symbolic representation is conventionally used for the information should be used for encoding the prtChannelInformation value. (For instance, a binary port value might be represented as a decimal number using NVT ASCII codes.) Such encoding must be specified in the definition of the value. b. The value may contain textual information in a character set other than NVT ASCII graphics characters. (For instance, an identifier might consist of ISO 10646 text encoded using the UTF-8 encoding scheme.) Such a character set and its encoding must be specified in the definition of the value. 6. For each PrtChannelType for which prtChannelInformation entries are defined, the descriptive text associated with the PrtChannelType enumeration value shall specify the following information for each entry: Title: Brief description phrase, e.g.: 'Port name', 'Service Name', etc. Keyword: The keyword value, e.g.: 'Port' or 'Service' Syntax: The encoding of the entry value if it cannot be directly represented by NVT ASCII. Status: 'Mandatory', 'Optional', or 'Conditionally Mandatory' Multiplicity: 'Single' or 'Multiple' to indicate whether the entry may be present multiple times. Description: Description of the use of the entry, other information required to complete the definition (e.g.: ordering constraints, interactions between entries). Applications that interpret prtChannelInformation should ignore unrecognized entries, so they are not affected if new entry types are added. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtInterpreter | 1.3.6.1.2.1.43.15 | ||
| OBJECT IDENTIFIER | |||
| prtInterpreterTable | 1.3.6.1.2.1.43.15.1 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtInterpreterEntry | |||
| prtInterpreterEntry | 1.3.6.1.2.1.43.15.1.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtInterpreterEntry | |||
| prtInterpreterIndex | 1.3.6.1.2.1.43.15.1.1.1 | ||
| A unique value for each PDL or control language for which there exists an interpreter or emulator in the printer. The value is used to identify this interpreter. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new interpreters to the printer), values are expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtInterpreterLangFamily | 1.3.6.1.2.1.43.15.1.1.2 | ||
| The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. | |||
| OBJECT-TYPE | |||
| PrtInterpreterLangFamilyTC | |||
| prtInterpreterLangLevel | 1.3.6.1.2.1.43.15.1.1.3 | ||
| The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of the PostScript language. Similarly it might contain '2' for an interpreter which is emulating level 2 of the HPGL language. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..31) | ||
| prtInterpreterLangVersion | 1.3.6.1.2.1.43.15.1.1.4 | ||
| The date code or version of the language which this interpreter is interpreting or emulating. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..31) | ||
| prtInterpreterDescription | 1.3.6.1.2.1.43.15.1.1.5 | ||
| A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interpreters. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtInterpreterVersion | 1.3.6.1.2.1.43.15.1.1.6 | ||
| The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..31) | ||
| prtInterpreterDefaultOrientation | 1.3.6.1.2.1.43.15.1.1.7 | ||
| The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream). | |||
| OBJECT-TYPE | |||
| PrtPrintOrientationTC | |||
| prtInterpreterFeedAddressability | 1.3.6.1.2.1.43.15.1.1.8 | ||
| The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInterpreterXFeedAddressability | 1.3.6.1.2.1.43.15.1.1.9 | ||
| The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtInterpreterDefaultCharSetIn | 1.3.6.1.2.1.43.15.1.1.10 | ||
| The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. (Input octets are presented to the interpreter through a path defined in the channel group.) This value shall be (2) if there is no default. | |||
| OBJECT-TYPE | |||
| CodedCharSet | |||
| prtInterpreterDefaultCharSetOut | 1.3.6.1.2.1.43.15.1.1.11 | ||
| The default character set for data coming from this interpreter through the printer's output channel (i.e. the 'backchannel'). This value shall be (2) if there is no default. | |||
| OBJECT-TYPE | |||
| CodedCharSet | |||
| prtInterpreterTwoWay | 1.3.6.1.2.1.43.15.1.1.12 | ||
| Indicates whether or not this interpreter returns information back to the host. | |||
| OBJECT-TYPE | |||
| PrtInterpreterTwoWayTC | |||
| prtConsoleDisplayBuffer | 1.3.6.1.2.1.43.16 | ||
| OBJECT IDENTIFIER | |||
| prtConsoleDisplayBufferTable | 1.3.6.1.2.1.43.16.5 | ||
| Physical display buffer for printer console display or operator panel | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtConsoleDisplayBufferEntry | |||
| prtConsoleDisplayBufferEntry | 1.3.6.1.2.1.43.16.5.1 | ||
| This table contains one entry for each physical line on the display. Lines cannot be added or deleted. Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtConsoleDisplayBufferEntry | |||
| prtConsoleDisplayBufferIndex | 1.3.6.1.2.1.43.16.5.1.1 | ||
| A unique value for each console line in the printer. The value is used to identify this console line. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new console lines to the printer). Values are normally expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtConsoleDisplayBufferText | 1.3.6.1.2.1.43.16.5.1.2 | ||
| The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is present. Writing a zero length string clears the line. It is an implementation-specific matter as to whether the agent allows a line to be overwritten before it has been cleared. Printer generated strings shall be in the localization specified by prtConsoleLocalization. Management Application generated strings should be localized by the Management Application. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtConsoleLights | 1.3.6.1.2.1.43.17 | ||
| OBJECT IDENTIFIER | |||
| prtConsoleLightTable | 1.3.6.1.2.1.43.17.6 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtConsoleLightEntry | |||
| prtConsoleLightEntry | 1.3.6.1.2.1.43.17.6.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtConsoleLightEntry | |||
| prtConsoleLightIndex | 1.3.6.1.2.1.43.17.6.1.1 | ||
| A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer). Values are normally expected to remain stable across successive printer power cycles. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtConsoleOnTime | 1.3.6.1.2.1.43.17.6.1.2 | ||
| This object, in conjunction with prtConsoleOffTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non- zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the lamp is off. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtConsoleOffTime | 1.3.6.1.2.1.43.17.6.1.3 | ||
| This object, in conjunction with prtConsoleOnTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non- zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the lamp is off. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtConsoleColor | 1.3.6.1.2.1.43.17.6.1.4 | ||
| The color of this light. | |||
| OBJECT-TYPE | |||
| PrtConsoleColorTC | |||
| prtConsoleDescription | 1.3.6.1.2.1.43.17.6.1.5 | ||
| The vendor description or label of this light in the localization specified by prtConsoleLocalization. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtAlert | 1.3.6.1.2.1.43.18 | ||
| OBJECT IDENTIFIER | |||
| prtAlertTable | 1.3.6.1.2.1.43.18.1 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| PrtAlertEntry | |||
| prtAlertEntry | 1.3.6.1.2.1.43.18.1.1 | ||
| Entries may exist in the table for each device index with a device type of 'printer'. | |||
| OBJECT-TYPE | |||
| PrtAlertEntry | |||
| prtAlertIndex | 1.3.6.1.2.1.43.18.1.1.1 | ||
| The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer starting from zero every time the printer is reset. When the printer adds an alert to the table, that alert is assigned the next higher integer value from the last item entered into the table. If the index value reaches its maximum value, the next item entered will cause the index value to roll over and start at zero again. The first event placed in the alert table after a reset of the printer shall have an index value of 1. NOTE: The management application will read the alert table when a trap or event notification occurs or at a periodic rate and then parse the table to determine if any new entries were added by comparing the last known index value with the current highest index value. The management application will then update its copy of the alert table. When the printer discovers that an alert is no longer active, the printer shall remove the row for that alert from the table and shall reduce the number of rows in the table. The printer may add or delete any number of rows from the table at any time. The management station can detect when binary change alerts have been deleted by requesting an attribute of each alert, and noting alerts as deleted when that retrieval is not possible. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..65535 | ||
| prtAlertSeverityLevel | 1.3.6.1.2.1.43.18.1.1.2 | ||
| The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. | |||
| OBJECT-TYPE | |||
| PrtAlertSeverityLevelTC | |||
| prtAlertTrainingLevel | 1.3.6.1.2.1.43.18.1.1.3 | ||
| See textual convention PrtAlertTrainingLevelTC | |||
| OBJECT-TYPE | |||
| PrtAlertTrainingLevelTC | |||
| prtAlertGroup | 1.3.6.1.2.1.43.18.1.1.4 | ||
| The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib. | |||
| OBJECT-TYPE | |||
| PrtAlertGroupTC | |||
| prtAlertGroupIndex | 1.3.6.1.2.1.43.18.1.1.5 | ||
| An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The combination of the prtAlertGroup and the prtAlertGroupIndex defines exactly which printer sub- unit caused the alert; for example, Input #3, Output #2, and Marker #1. Every object in this MIB is indexed with hrDeviceIndex and optionally, another index variable. If this other index variable is present in the table that generated the alert, it will be used as the value for this object. Otherwise, this value shall be -1. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtAlertLocation | 1.3.6.1.2.1.43.18.1.1.6 | ||
| The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7. The value (-2) indicates unknown | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| prtAlertCode | 1.3.6.1.2.1.43.18.1.1.7 | ||
| See associated textual convention PrtAlertCodeTC | |||
| OBJECT-TYPE | |||
| PrtAlertCodeTC | |||
| prtAlertDescription | 1.3.6.1.2.1.43.18.1.1.8 | ||
| A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elaborate on the enumerated alert or provide information in the case where the code is classified as 'other' or 'unknown'. The printer is required to return a description string but the string may be a null string. | |||
| OBJECT-TYPE | |||
| OCTET STRING | SIZE(0..255) | ||
| prtAlertTime | 1.3.6.1.2.1.43.18.1.1.9 | ||
| The value of sysUpTime at the time that this alert was generated. | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| printerV1Alert | 1.3.6.1.2.1.43.18.2 | ||
| The value of the enterprise-specific OID in an SNMPv1 trap sent signaling a critical event in the prtAlertTable. | |||
| OBJECT-IDENTITY | |||
| printerV2AlertPrefix | 1.3.6.1.2.1.43.18.2.0 | ||
| OBJECT IDENTIFIER | |||
| printerV2Alert | 1.3.6.1.2.1.43.18.2.0.1 | ||
| This trap is sent whenever a critical event is added to the prtAlertTable. | |||
| NOTIFICATION-TYPE | |||
| prtAlertIndex | |||
| prtAlertSeverityLevel | |||
| prtAlertGroup | |||
| prtAlertGroupIndex | |||
| prtAlertLocation | |||
| prtAlertCode | |||
| PrtMediaUnitTC | |||
| Units of measure for media dimensions. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | tenThousandthsOfInches(3), micrometers(4) | ||
| PrtCapacityUnitTC | |||
| Units of measure for media capacity. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | tenThousandthsOfInches(3), micrometers(4), sheets(8), feet(16), meters(17) | ||
| PrtPrintOrientationTC | |||
| A generic representation for printing orientation on a 'page'. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), portrait(3), landscape(4) | ||
| PrtCoverStatusTC | |||
| Values for encoding the state of a particular cover or access panel on the printer case or enclosure. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), coverOpen(3), coverClosed(4), interlockOpen(5), interlockClosed(6) | ||
| PrtSubUnitStatusTC | |||
| Status of a printer sub-unit. The SubUnitStatus is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability Value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line State is On-Line 0 State is Off-Line 32 Transitioning Currently at intended state 0 Transitioning to intended state 64 | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | 0..126 | ||
| PresentOnOff | |||
| Presence and configuration of a device or feature. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), on(3), off(4), notPresent(5) | ||
| CodedCharSet | |||
| A coded character set value that specifies both a set of characters that may be used and an encoding (as one or more octets) that is used to represent the characters in the set. These values are to be used to identify the encoding employed for strings in the MIB where this is not fixed by the MIB. Some objects that allow a choice of coded character set are: the prtLocalizationCharacterSet object in the LocalizationTable and prtInterpreterDefaultCharSetIn. The prtGeneralCurrentLocalization and prtConsoleLocalization objects in turn contain the index in the LocalizationTable of the current localization (country, language, and coded character set) of the 'description' objects and the console, respectively. The space of the coded character set enumeration has been divided into three regions. The first region (3- 999) consists of coded character sets that have been standardized by some standard setting organization. This region is intended for standards that do not have subset implementations. The second region (1000-1999) is for the Unicode and ISO/IEC 10646 coded character sets together with a specification of a (set of) sub- repertoires that may occur. The third region (>1999) is intended for vendor specific coded character sets. NOTE: Unicode and ISO 10646 character coded data may be processed and stored in either Big Endian (most significant octet first) or Little Endian (least significant octet first) order. Intel x86, VAX, and Alpha/AXP architectures are examples of Little Endian processor architectures. Furthermore, in environments where either order may occur, so-called Unicode BYTE ORDER MARK (BOM) character (which is ISO 10646 ZERO WIDTH NO BREAK SPACE), coded as FEFF in two octets and 0000FEFF in four octets is used at the beginning of the data as a signature to indicate the order of the following data (See ISO 10646 Annex F). Thus either ordering and BOM may occur in print data streams sent to the interpreter. However, ISO 8824/8825 (ASN.1/BER) used by SNMP is quite clear that Big Endian order shall be used and BOM shall NOT be used in transmission in the protocol. Transmitting Unicode in Big Endian order in SNMP should not prove to be a hardship for Little Endian machines, since SNMP ASN.1/BER requires integers to be transmitted in Big Endian order as well. So SNMP implementations on Little Endian machines are already reversing the order of integers to make them Big Endian for transmission via SNMP. Also Unicode characters are usually treated as two-octet integers, not short text strings, so that it will be straightforward for Little Endian machines to reverse the order of Unicode character octets as well before transmitting them and after receiving them via the SNMP protocol. Where a given coded character set may be known by more than one name, the most commonly known name is used as the name of the enumeration and other names are shown in the comments. The comments also indicate where to find detailed information on the coded character set and briefly characterize its relationship to other similar coded character sets. The current list of character sets and their enumerated values used to reference them is contained in the IANA Character Set registry. The enum value is indicated by the MIB enum entry in the registry. The enum symbol is indicated by the Alias that starts with 'cs' for character set. The IANA character sets registry is available via anonymous ftp. The ftp server is ftp.isi.edu. The subdirectory is /in- notes/iana/assignments/. The file name is character-sets. To add a character set to the IANA Registry: 1. Format an entry like those in the current list, omitting the MIBenum value. 2. Send the entry with a request to add the entry to the character set list to [email protected]. 3. The IANA will supply a unique MIBenum value and update the list. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1) | ||
| PrtGeneralResetTC | |||
| Values for reading and writing the prtGeneralReset object. If a device does not have NVRAM, the device shall none the less respond to a SET with the value resetToNVRAM(5) with some sort of warm reset that resets the device to some implementation-defined state that is preferably under control of the system administrator by some means outside the scope of this MIB specification. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | notResetting(3), powerCycleReset(4), resetToNVRAM(5), resetToFactoryDefaults(6) | ||
| PrtChannelStateTC | |||
| The state of this print job delivery channel. The value determine whether control information and print data is allowed through this channel. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), printDataAccepted(3), noDataAccepted(4) | ||
| PrtChannelTypeTC | |||
| This enumeration indicates the type of channel that is receiving jobs. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), chSerialPort(3), chParallelPort(4), chIEEE1284Port(5), chSCSIPort(6), chAppleTalkPAP(7), chLPDServer(8), chNetwareRPrinter(9), chNetwarePServer(10), chPort9100(11), chAppSocket(12), chFTP(13), chTFTP(14), chDLCLLCPort(15), chIBM3270(16), chIBM5250(17), chFax(18), chIEEE1394(19), chTransport1(20), chCPAP(21), chPCPrint(26), chServerMessageBlock(27), chPSM(28), chSystemObjectManager(31), chDECLAT(32), chNPAP(33), chUSB(34), chIRDA(35), chPrintXChange(36), chPortTCP(37), chBidirPortTCP(38), chUNPP(39), chAppleTalkADSP(40), chPortSPX(41), chPortHTTP(42), chNDPS(43) | ||
| PrtInterpreterLangFamilyTC | |||
| This enumeration indicates the type of interpreter that is receiving jobs. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), langPCL(3), langHPGL(4), langPJL(5), langPS(6), langIPDS(7), langPPDS(8), langEscapeP(9), langEpson(10), langDDIF(11), langInterpress(12), langISO6429(13), langLineData(14), langMODCA(15), langREGIS(16), langSCS(17), langSPDL(18), langTEK4014(19), langPDS(20), langIGP(21), langCodeV(22), langDSCDSE(23), langWPS(24), langLN03(25), langCCITT(26), langQUIC(27), langCPAP(28), langDecPPL(29), langSimpleText(30), langNPAP(31), langDOC(32), langimPress(33), langPinwriter(34), langNPDL(35), langNEC201PL(36), langAutomatic(37), langPages(38), langLIPS(39), langTIFF(40), langDiagnostic(41), langPSPrinter(42), langCaPSL(43), langEXCL(44), langLCDS(45), langXES(46), langPCLXL(47), langART(48), langTIPSI(49), langPrescribe(50), langLinePrinter(51), langIDP(52), langXJCL(53), langPDF(54), langRPDL(55), langIntermecIPL(56), langUBIFingerprint(57), langUBIDirectProtocol(58), langFujitsu(59) | ||
| PrtInputTypeTC | |||
| The type of technology (discriminated primarily according to feeder mechanism type) employed by a specific component or components. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), sheetFeedAutoRemovableTray(3), sheetFeedAutoNonRemovableTray(4), sheetFeedManual(5), continuousRoll(6), continuousFanFold(7) | ||
| PrtOutputTypeTC | |||
| The Type of technology supported by this output sub- unit | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), removableBin(3), unRemovableBin(4), continuousRollDevice(5), mailBox(6), continuousFanFold(7) | ||
| PrtOutputStackingOrderTC | |||
| The current state of the stacking order for the associated output sub-unit. 'firstToLast' means that as pages are output, the front of the next page is placed against the back of the previous page. 'lastToFirst' means that as pages are output, the back of the next page is placed against the front of the previous page. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | unknown(2), firstToLast(3), lastToFirst(4) | ||
| PrtOutputPageDeliveryOrientationTC | |||
| The reading surface that will be 'up' when pages are delivered to the associated output sub-unit. Values are Face-Up and Face-Down (Note: interpretation of these values is, in general, context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | faceUp(3), faceDown(4) | ||
| PrtMarkerMarkTechTC | |||
| The type of marking technology used for this marking sub-unit | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), electrophotographicLED(3), electrophotographicLaser(4), electrophotographicOther(5), impactMovingHeadDotMatrix9pin(6), impactMovingHeadDotMatrix24pin(7), impactMovingHeadDotMatrixOther(8), impactMovingHeadFullyFormed(9), impactBand(10), impactOther(11), inkjetAqueous(12), inkjetSolid(13), inkjetOther(14), pen(15), thermalTransfer(16), thermalSensitive(17), thermalDiffusion(18), thermalOther(19), electroerosion(20), electrostatic(21), photographicMicrofiche(22), photographicImagesetter(23), photographicOther(24), ionDeposition(25), eBeam(26), typesetter(27) | ||
| PrtMarkerCounterUnitTC | |||
| The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | tenThousandthsOfInches(3), micrometers(4), characters(5), lines(6), impressions(7), sheets(8), dotRow(9), hours(11), feet(16), meters(17) | ||
| PrtMarkerSuppliesTypeTC | |||
| The type of this supply. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), toner(3), wasteToner(4), ink(5), inkCartridge(6), inkRibbon(7), wasteInk(8), opc(9), developer(10), fuserOil(11), solidWax(12), ribbonWax(13), wasteWax(14), fuser(15), coronaWire(16), fuserOilWick(17), cleanerUnit(18), fuserCleaningPad(19), transferUnit(20), tonerCartridge(21), fuserOiler(22), water(23), wasteWater(24), glueWaterAdditive(25), wastePaper(26), bindingSupply(27), bandingSupply(28), stitchingWire(29), shrinkWrap(30), paperWrap(31), staples(32), inserts(33), covers(34) | ||
| PrtMarkerSuppliesSupplyUnitTC | |||
| Unit of this marker supply container/receptacle. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | tenThousandthsOfInches(3), micrometers(4), impressions(7), sheets(8), hours(11), thousandthsOfOunces(12), tenthsOfGrams(13), hundrethsOfFluidOunces(14), tenthsOfMilliliters(15), feet(16), meters(17), items(18) | ||
| PrtMarkerSuppliesClassTC | |||
| Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), supplyThatIsConsumed(3), receptacleThatIsFilled(4) | ||
| PrtMarkerColorantRoleTC | |||
| The role played by this colorant. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), process(3), spot(4) | ||
| PrtMediaPathMaxSpeedPrintUnitTC | |||
| The unit of measure used in specifying the speed of all media paths in the printer. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | tenThousandthsOfInchesPerHour(3), micrometersPerHour(4), charactersPerHour(5), linesPerHour(6), impressionsPerHour(7), sheetsPerHour(8), dotRowPerHour(9), feetPerHour(16), metersPerHour(17) | ||
| PrtMediaPathTypeTC | |||
| The type of the media path for this media path. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), longEdgeBindingDuplex(3), shortEdgeBindingDuplex(4), simplex(5) | ||
| PrtInterpreterTwoWayTC | |||
| Indicates whether or not this interpreter returns information back to the host. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | yes(3), no(4) | ||
| PrtConsoleColorTC | |||
| The color of this light. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), white(3), red(4), green(5), blue(6), cyan(7), magenta(8), yellow(9), orange(10) | ||
| PrtAlertSeverityLevelTC | |||
| The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. A warning is defined to be a non- critical alert. The value also indicates whether the event is a binary change event or a unary change event. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), criticalBinaryChangeEvent(3), warningUnaryChangeEvent(4), warningBinaryChangeEvent(5) | ||
| PrtAlertTrainingLevelTC | |||
| The level of training required to handle this alert, if human intervention is required. The noInterventionRequired value should be used if the event does not require any human intervention. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or the training required to handle this alert. The printer will break alerts into these different training levels. It is the responsibility of the management application in the system to determine how a particular alert is handled and how and to whom that alert is routed. The following are the four training levels of alerts: Field Service - Alerts that typically require advanced training and technical knowledge of the printer and its sub-units. An example of a technical person would be a manufacturer's Field Service representative, or other person formally trained by the manufacturer or similar representative. Trained - Alerts that require an intermediate or moderate level of knowledge of the printer and its sub-units. A typical examples of alerts that a trained operator can handle is replacing toner cartridges. Untrained - Alerts that can be fixed without prior training either because the action to correct the alert is obvious or the printer can help the untrained person fix the problem. A typical example of such an alert is reloading paper trays and emptying output bins on a low end printer. Management - Alerts that have to do with overall operation of and configuration of the printer. Examples of management events are configuration change of sub-units. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), untrained(3), trained(4), fieldService(5), management(6), noInterventionRequired(7) | ||
| PrtAlertGroupTC | |||
| The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printer MIB. NOTE: Alert type codes have been added for the host resources MIB storage table and device table. These additional types are for situations in which the printer's storage and device objects must generate alerts (and possibly traps for critical alerts). | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), hostResourcesMIBStorageTable(3), hostResourcesMIBDeviceTable(4), generalPrinter(5), cover(6), localization(7), input(8), output(9), marker(10), markerSupplies(11), markerColorant(12), mediaPath(13), channel(14), interpreter(15), consoleDisplayBuffer(16), consoleLights(17), alert(18), finDevice(30), finSupply(31), finSupplyMediaInput(32), finAttributeTable(33) | ||
| PrtAlertCodeTC | |||
| The code that describes the type of alert for this entry in the table. Binary change event alerts describe states of the subunit while unary change event alerts describe a single event. The same alert code can be used for a binary change event or a unary change event, depending on implementation. Also, the same alert code can be used to indicate a critical or a non-critical (warning) alert, depending on implementation. The value of prtAlertSeverityLevel specifies binary vs. unary and critical vs. non-critical for each event for the implementation. While there are some specific codes for many subunits, the generic codes should be used for most subunit alerts. The network management station can then query the subunit specified by prtAlertGroup to determine further subunit status and other subunit information. An agent shall not add two entries to the alert table for the same event, one containing a generic event code and the other containing a specific event code; the agent shall add only one entry in the alert table for each event; either generic (preferred) or specific, not both. Implementation of the unary change event alertRemovalOfBinaryChangeEntry(1801) is optional. When implemented, this alert code shall indicate to network management stations that the trailing edge of a binary change event has occurred and the corresponding alert entry has been removed from the alert table. As with all events, the alertRemovalOfBinaryChangeEntry(1801) alert shall be placed at the end of the alert table. Such an alert table entry shall specify the following information: prtAlertSeverityLevel warningUnaryChangeEvent(4) prtAlertTrainingLevel noInterventionRequired(7) prtAlertGroup alert(18) prtAlertGroupIndex the index of the row in the alert table of the binary change event that this event has removed. prtAlertLocation unknown (-2) prtAlertCode alertRemovalOfBinaryChangeEntry(1801) prtAlertDescription prtAlertTime the value of sysUpTime at the time of the removal of the binary change event from the alert table. Optionally, the agent may generate a trap coincident with removing the binary change event and placing the unary change event alertRemovalOfBinaryChangeEntry(1801) in the alert table. For such a trap, the prtAlertIndex sent with the above trap parameters shall be the index of the alertRemovalOfBinaryChangeEvent row that was added to the prtAlertTable; not the index of the row that was removed from the prtAlertTable. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | other(1), unknown(2), coverOpened(3), coverClosed(4), interlockOpened(5), interlockClosed(6), configurationChanged(7), jammed(8), subunitMissing(9), subunitLifeAlmostOver(10), subunitLifeOver(11), subunitAlmostEmpty(12), subunitEmpty(13), subunitAlmostFull(14), subunitFull(15), subunitNearLimit(16), subunitAtLimit(17), subunitOpened(18), subunitClosed(19), subunitTurnedOn(20), subunitTurnedOff(21), subunitOffline(22), subunitPowerSaver(23), subunitWarmingUp(24), subunitAdded(25), subunitRemoved(26), subunitResourceAdded(27), subunitResourceRemoved(28), subunitRecoverableFailure(29), subunitUnrecoverableFailure(30), subunitRecoverableStorageError(31), subunitUnrecoverableStorageError(32), subunitMotorFailure(33), subunitMemoryExhausted(34), subunitUnderTemperature(35), subunitOverTemperature(36), subunitTimingFailure(37), subunitThermistorFailure(38), doorOpen(501), doorClosed(502), poweredUp(503), poweredDown(504), printerNMSReset(505), printerManualReset(506), printerReadyToPrint(507), inputMediaTrayMissing(801), inputMediaSizeChanged(802), inputMediaWeightChanged(803), inputMediaTypeChanged(804), inputMediaColorChanged(805), inputMediaFormPartsChange(806), inputMediaSupplyLow(807), inputMediaSupplyEmpty(808), inputMediaChangeRequest(809), inputManualInputRequest(810), inputTrayPositionFailure(811), inputTrayElevationFailure(812), inputCannotFeedSizeSelected(813), outputMediaTrayMissing(901), outputMediaTrayAlmostFull(902), outputMediaTrayFull(903), outputMailboxSelectFailure(904), markerFuserUnderTemperature(1001), markerFuserOverTemperature(1002), markerFuserTimingFailure(1003), markerFuserThermistorFailure(1004), markerAdjustingPrintQuality(1005), markerTonerEmpty(1101), markerInkEmpty(1102), markerPrintRibbonEmpty(1103), markerTonerAlmostEmpty(1104), markerInkAlmostEmpty(1105), markerPrintRibbonAlmostEmpty(1106), markerWasteTonerReceptacleAlmostFull(1107), markerWasteInkReceptacleAlmostFull(1108), markerWasteTonerReceptacleFull(1109), markerWasteInkReceptacleFull(1110), markerOpcLifeAlmostOver(1111), markerOpcLifeOver(1112), markerDeveloperAlmostEmpty(1113), markerDeveloperEmpty(1114), markerTonerCartridgeMissing(1115), mediaPathMediaTrayMissing(1301), mediaPathMediaTrayAlmostFull(1302), mediaPathMediaTrayFull(1303), interpreterMemoryIncreased(1501), interpreterMemoryDecreased(1502), interpreterCartridgeAdded(1503), interpreterCartridgeDeleted(1504), interpreterResourceAdded(1505), interpreterResourceDeleted(1506), interpreterResourceUnavailable(1507), interpreterComplexPageEncountered(1509), alertRemovalOfBinaryChangeEntry(1801) | ||
| PrtGeneralEntry | |||
| SEQUENCE | |||
| Counter32 as prtGeneralConfigChanges | |||
| Integer32 as prtGeneralCurrentLocalization | |||
| PrtGeneralResetTC as prtGeneralReset | |||
| OCTET STRING as prtGeneralCurrentOperator | |||
| OCTET STRING as prtGeneralServicePerson | |||
| Integer32 as prtInputDefaultIndex | |||
| Integer32 as prtOutputDefaultIndex | |||
| Integer32 as prtMarkerDefaultIndex | |||
| Integer32 as prtMediaPathDefaultIndex | |||
| Integer32 as prtConsoleLocalization | |||
| Integer32 as prtConsoleNumberOfDisplayLines | |||
| Integer32 as prtConsoleNumberOfDisplayChars | |||
| INTEGER as prtConsoleDisable | |||
| PresentOnOff as prtAuxiliarySheetStartupPage | |||
| PresentOnOff as prtAuxiliarySheetBannerPage | |||
| OCTET STRING as prtGeneralPrinterName | |||
| OCTET STRING as prtGeneralSerialNumber | |||
| Counter32 as prtAlertCriticalEvents | |||
| Counter32 as prtAlertAllEvents | |||
| PrtCoverEntry | |||
| SEQUENCE | |||
| Integer32 as prtCoverIndex | |||
| OCTET STRING as prtCoverDescription | |||
| PrtCoverStatusTC as prtCoverStatus | |||
| PrtLocalizationEntry | |||
| SEQUENCE | |||
| Integer32 as prtLocalizationIndex | |||
| DisplayString as prtLocalizationLanguage | |||
| DisplayString as prtLocalizationCountry | |||
| CodedCharSet as prtLocalizationCharacterSet | |||
| PrtStorageRefEntry | |||
| SEQUENCE | |||
| Integer32 as prtStorageRefSeqNumber | |||
| Integer32 as prtStorageRefIndex | |||
| PrtDeviceRefEntry | |||
| SEQUENCE | |||
| Integer32 as prtDeviceRefSeqNumber | |||
| Integer32 as prtDeviceRefIndex | |||
| PrtInputEntry | |||
| SEQUENCE | |||
| Integer32 as prtInputIndex | |||
| PrtInputTypeTC as prtInputType | |||
| PrtMediaUnitTC as prtInputDimUnit | |||
| Integer32 as prtInputMediaDimFeedDirDeclared | |||
| Integer32 as prtInputMediaDimXFeedDirDeclared | |||
| Integer32 as prtInputMediaDimFeedDirChosen | |||
| Integer32 as prtInputMediaDimXFeedDirChosen | |||
| PrtCapacityUnitTC as prtInputCapacityUnit | |||
| Integer32 as prtInputMaxCapacity | |||
| Integer32 as prtInputCurrentLevel | |||
| PrtSubUnitStatusTC as prtInputStatus | |||
| OCTET STRING as prtInputMediaName | |||
| OCTET STRING as prtInputName | |||
| OCTET STRING as prtInputVendorName | |||
| OCTET STRING as prtInputModel | |||
| OCTET STRING as prtInputVersion | |||
| OCTET STRING as prtInputSerialNumber | |||
| OCTET STRING as prtInputDescription | |||
| PresentOnOff as prtInputSecurity | |||
| Integer32 as prtInputMediaWeight | |||
| OCTET STRING as prtInputMediaType | |||
| OCTET STRING as prtInputMediaColor | |||
| Integer32 as prtInputMediaFormParts | |||
| Integer32 as prtInputMediaLoadTimeout | |||
| Integer32 as prtInputNextIndex | |||
| PrtOutputEntry | |||
| SEQUENCE | |||
| Integer32 as prtOutputIndex | |||
| PrtOutputTypeTC as prtOutputType | |||
| PrtCapacityUnitTC as prtOutputCapacityUnit | |||
| Integer32 as prtOutputMaxCapacity | |||
| Integer32 as prtOutputRemainingCapacity | |||
| PrtSubUnitStatusTC as prtOutputStatus | |||
| OCTET STRING as prtOutputName | |||
| OCTET STRING as prtOutputVendorName | |||
| OCTET STRING as prtOutputModel | |||
| OCTET STRING as prtOutputVersion | |||
| OCTET STRING as prtOutputSerialNumber | |||
| OCTET STRING as prtOutputDescription | |||
| PresentOnOff as prtOutputSecurity | |||
| PrtMediaUnitTC as prtOutputDimUnit | |||
| Integer32 as prtOutputMaxDimFeedDir | |||
| Integer32 as prtOutputMaxDimXFeedDir | |||
| Integer32 as prtOutputMinDimFeedDir | |||
| Integer32 as prtOutputMinDimXFeedDir | |||
| PrtOutputStackingOrderTC as prtOutputStackingOrder | |||
| PrtOutputPageDeliveryOrientationTC as prtOutputPageDeliveryOrientation | |||
| PresentOnOff as prtOutputBursting | |||
| PresentOnOff as prtOutputDecollating | |||
| PresentOnOff as prtOutputPageCollated | |||
| PresentOnOff as prtOutputOffsetStacking | |||
| PrtMarkerEntry | |||
| SEQUENCE | |||
| Integer32 as prtMarkerIndex | |||
| PrtMarkerMarkTechTC as prtMarkerMarkTech | |||
| PrtMarkerCounterUnitTC as prtMarkerCounterUnit | |||
| Counter32 as prtMarkerLifeCount | |||
| Counter32 as prtMarkerPowerOnCount | |||
| Integer32 as prtMarkerProcessColorants | |||
| Integer32 as prtMarkerSpotColorants | |||
| INTEGER as prtMarkerAddressabilityUnit | |||
| Integer32 as prtMarkerAddressabilityFeedDir | |||
| Integer32 as prtMarkerAddressabilityXFeedDir | |||
| Integer32 as prtMarkerNorthMargin | |||
| Integer32 as prtMarkerSouthMargin | |||
| Integer32 as prtMarkerWestMargin | |||
| Integer32 as prtMarkerEastMargin | |||
| PrtSubUnitStatusTC as prtMarkerStatus | |||
| PrtMarkerSuppliesEntry | |||
| SEQUENCE | |||
| Integer32 as prtMarkerSuppliesIndex | |||
| Integer32 as prtMarkerSuppliesMarkerIndex | |||
| Integer32 as prtMarkerSuppliesColorantIndex | |||
| PrtMarkerSuppliesClassTC as prtMarkerSuppliesClass | |||
| PrtMarkerSuppliesTypeTC as prtMarkerSuppliesType | |||
| OCTET STRING as prtMarkerSuppliesDescription | |||
| PrtMarkerSuppliesSupplyUnitTC as prtMarkerSuppliesSupplyUnit | |||
| Integer32 as prtMarkerSuppliesMaxCapacity | |||
| Integer32 as prtMarkerSuppliesLevel | |||
| PrtMarkerColorantEntry | |||
| SEQUENCE | |||
| Integer32 as prtMarkerColorantIndex | |||
| Integer32 as prtMarkerColorantMarkerIndex | |||
| PrtMarkerColorantRoleTC as prtMarkerColorantRole | |||
| OCTET STRING as prtMarkerColorantValue | |||
| Integer32 as prtMarkerColorantTonality | |||
| PrtMediaPathEntry | |||
| SEQUENCE | |||
| Integer32 as prtMediaPathIndex | |||
| PrtMediaPathMaxSpeedPrintUnitTC as prtMediaPathMaxSpeedPrintUnit | |||
| PrtMediaUnitTC as prtMediaPathMediaSizeUnit | |||
| Integer32 as prtMediaPathMaxSpeed | |||
| Integer32 as prtMediaPathMaxMediaFeedDir | |||
| Integer32 as prtMediaPathMaxMediaXFeedDir | |||
| Integer32 as prtMediaPathMinMediaFeedDir | |||
| Integer32 as prtMediaPathMinMediaXFeedDir | |||
| PrtMediaPathTypeTC as prtMediaPathType | |||
| OCTET STRING as prtMediaPathDescription | |||
| PrtSubUnitStatusTC as prtMediaPathStatus | |||
| PrtChannelEntry | |||
| SEQUENCE | |||
| Integer32 as prtChannelIndex | |||
| PrtChannelTypeTC as prtChannelType | |||
| OCTET STRING as prtChannelProtocolVersion | |||
| Integer32 as prtChannelCurrentJobCntlLangIndex | |||
| Integer32 as prtChannelDefaultPageDescLangIndex | |||
| PrtChannelStateTC as prtChannelState | |||
| Integer32 as prtChannelIfIndex | |||
| PrtSubUnitStatusTC as prtChannelStatus | |||
| OCTET STRING as prtChannelInformation | |||
| PrtInterpreterEntry | |||
| SEQUENCE | |||
| Integer32 as prtInterpreterIndex | |||
| PrtInterpreterLangFamilyTC as prtInterpreterLangFamily | |||
| OCTET STRING as prtInterpreterLangLevel | |||
| OCTET STRING as prtInterpreterLangVersion | |||
| OCTET STRING as prtInterpreterDescription | |||
| OCTET STRING as prtInterpreterVersion | |||
| PrtPrintOrientationTC as prtInterpreterDefaultOrientation | |||
| Integer32 as prtInterpreterFeedAddressability | |||
| Integer32 as prtInterpreterXFeedAddressability | |||
| CodedCharSet as prtInterpreterDefaultCharSetIn | |||
| CodedCharSet as prtInterpreterDefaultCharSetOut | |||
| PrtInterpreterTwoWayTC as prtInterpreterTwoWay | |||
| PrtConsoleDisplayBufferEntry | |||
| SEQUENCE | |||
| Integer32 as prtConsoleDisplayBufferIndex | |||
| OCTET STRING as prtConsoleDisplayBufferText | |||
| PrtConsoleLightEntry | |||
| SEQUENCE | |||
| Integer32 as prtConsoleLightIndex | |||
| Integer32 as prtConsoleOnTime | |||
| Integer32 as prtConsoleOffTime | |||
| PrtConsoleColorTC as prtConsoleColor | |||
| OCTET STRING as prtConsoleDescription | |||
| PrtAlertEntry | |||
| SEQUENCE | |||
| Integer32 as prtAlertIndex | |||
| PrtAlertSeverityLevelTC as prtAlertSeverityLevel | |||
| PrtAlertTrainingLevelTC as prtAlertTrainingLevel | |||
| PrtAlertGroupTC as prtAlertGroup | |||
| Integer32 as prtAlertGroupIndex | |||
| Integer32 as prtAlertLocation | |||
| PrtAlertCodeTC as prtAlertCode | |||
| OCTET STRING as prtAlertDescription | |||
| TimeTicks as prtAlertTime | |||