RC7586-MIB

File: RC7586-MIB.mib (28672 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC CODAN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 TimeTicks IpAddress
Gauge32 Counter32 DisplayString
DateAndTime TEXTUAL-CONVENTION TestAndIncr
TimeInterval TruthValue satcomMibs

Defined Objects

rc7586MIB 1.3.6.1.4.1.23304.2.2
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
MODULE-IDENTITY    

buc1 1.3.6.1.4.1.23304.2.2.1
OBJECT IDENTIFIER    

buc1Configuration 1.3.6.1.4.1.23304.2.2.1.1
OBJECT IDENTIFIER    

buc1TxSettings 1.3.6.1.4.1.23304.2.2.1.1.1
OBJECT IDENTIFIER    

buc1TxOn 1.3.6.1.4.1.23304.2.2.1.1.1.1
Sets Tx on/off. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxDefault 1.3.6.1.4.1.23304.2.2.1.1.1.2
Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxAttenuator 1.3.6.1.4.1.23304.2.2.1.1.1.3
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..15  

buc1PktProtocol 1.3.6.1.4.1.23304.2.2.1.1.2
OBJECT IDENTIFIER    

buc1Protocol 1.3.6.1.4.1.23304.2.2.1.1.2.1
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..4  

buc1Address 1.3.6.1.4.1.23304.2.2.1.1.2.2
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER  

buc1RCSetting 1.3.6.1.4.1.23304.2.2.1.1.3
OBJECT IDENTIFIER    

buc1Mode 1.3.6.1.4.1.23304.2.2.1.1.3.1
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..2  

buc1OnLine 1.3.6.1.4.1.23304.2.2.1.1.3.2
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  TruthValue  

buc1Freqs 1.3.6.1.4.1.23304.2.2.1.1.4
OBJECT IDENTIFIER    

buc1RFFreq 1.3.6.1.4.1.23304.2.2.1.1.4.1
Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER  

buc1IFFreq 1.3.6.1.4.1.23304.2.2.1.1.4.2
Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER  

buc1LOFreq 1.3.6.1.4.1.23304.2.2.1.1.4.3
Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER  

buc1Misc 1.3.6.1.4.1.23304.2.2.1.1.5
OBJECT IDENTIFIER    

buc1SerIf 1.3.6.1.4.1.23304.2.2.1.1.5.1
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1PwrAlarmThresh 1.3.6.1.4.1.23304.2.2.1.1.5.2
Sets/Gets power alarm threshold. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1BurstPwrThresh 1.3.6.1.4.1.23304.2.2.1.1.5.3
Sets/Gets burst power threshold. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1RefSource 1.3.6.1.4.1.23304.2.2.1.1.5.4
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1LEDState 1.3.6.1.4.1.23304.2.2.1.1.5.5
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Status 1.3.6.1.4.1.23304.2.2.1.2
OBJECT IDENTIFIER    

buc1PaStatus 1.3.6.1.4.1.23304.2.2.1.2.1
Gets to 1 when PA is on. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc1TxPower 1.3.6.1.4.1.23304.2.2.1.2.2
Gets Tx power format x.x dB. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1TxBurstPower 1.3.6.1.4.1.23304.2.2.1.2.3
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Faults 1.3.6.1.4.1.23304.2.2.1.2.4
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc1LatchedFaults 1.3.6.1.4.1.23304.2.2.1.2.5
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc1Temperature 1.3.6.1.4.1.23304.2.2.1.2.6
Gets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1MinMaxTemperature 1.3.6.1.4.1.23304.2.2.1.2.7
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1SystemSetting 1.3.6.1.4.1.23304.2.2.1.2.8
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..2047  

buc1SystemPoll 1.3.6.1.4.1.23304.2.2.1.2.9
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.
OBJECT-TYPE    
  INTEGER 0..3  

buc1DeviceType 1.3.6.1.4.1.23304.2.2.1.2.10
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Gateway 1.3.6.1.4.1.23304.2.2.1.2.11
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1IpAddress 1.3.6.1.4.1.23304.2.2.1.2.12
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1MACAddress 1.3.6.1.4.1.23304.2.2.1.2.13
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Netmask 1.3.6.1.4.1.23304.2.2.1.2.14
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1RefPower 1.3.6.1.4.1.23304.2.2.1.2.15
Gets the BUC reference power. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Config 1.3.6.1.4.1.23304.2.2.1.2.16
Gets the BUC configuration. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1BuildStandard 1.3.6.1.4.1.23304.2.2.1.2.17
Gets the BUC build standard. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Info 1.3.6.1.4.1.23304.2.2.1.3
OBJECT IDENTIFIER    

buc1IdInfo 1.3.6.1.4.1.23304.2.2.1.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1Limits 1.3.6.1.4.1.23304.2.2.1.3.2
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc1PktProtocolsInfo 1.3.6.1.4.1.23304.2.2.1.3.3
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.
OBJECT-TYPE    
  DisplayString  

buc2 1.3.6.1.4.1.23304.2.2.2
OBJECT IDENTIFIER    

buc2Configuration 1.3.6.1.4.1.23304.2.2.2.1
OBJECT IDENTIFIER    

buc2TxSettings 1.3.6.1.4.1.23304.2.2.2.1.1
OBJECT IDENTIFIER    

buc2TxOn 1.3.6.1.4.1.23304.2.2.2.1.1.1
Sets Tx on/off. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc2TxDefault 1.3.6.1.4.1.23304.2.2.2.1.1.2
Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc2TxAttenuator 1.3.6.1.4.1.23304.2.2.2.1.1.3
Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..15  

buc2PktProtocol 1.3.6.1.4.1.23304.2.2.2.1.2
OBJECT IDENTIFIER    

buc2Protocol 1.3.6.1.4.1.23304.2.2.2.1.2.1
Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..4  

buc2Address 1.3.6.1.4.1.23304.2.2.2.1.2.2
Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2RCSetting 1.3.6.1.4.1.23304.2.2.2.1.3
OBJECT IDENTIFIER    

buc2Mode 1.3.6.1.4.1.23304.2.2.2.1.3.1
Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..2  

buc2OnLine 1.3.6.1.4.1.23304.2.2.2.1.3.2
Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  TruthValue  

buc2Freqs 1.3.6.1.4.1.23304.2.2.2.1.4
OBJECT IDENTIFIER    

buc2RFFreq 1.3.6.1.4.1.23304.2.2.2.1.4.1
Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2IFFreq 1.3.6.1.4.1.23304.2.2.2.1.4.2
Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2LOFreq 1.3.6.1.4.1.23304.2.2.2.1.4.3
Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2Misc 1.3.6.1.4.1.23304.2.2.2.1.5
OBJECT IDENTIFIER    

buc2SerIf 1.3.6.1.4.1.23304.2.2.2.1.5.1
Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2PwrAlarmThresh 1.3.6.1.4.1.23304.2.2.2.1.5.2
Sets/Gets power alarm threshold. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2BurstPwrThresh 1.3.6.1.4.1.23304.2.2.2.1.5.3
Sets/Gets burst power threshold. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2RefSource 1.3.6.1.4.1.23304.2.2.2.1.5.4
Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2LEDState 1.3.6.1.4.1.23304.2.2.2.1.5.5
Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Status 1.3.6.1.4.1.23304.2.2.2.2
OBJECT IDENTIFIER    

buc2PaStatus 1.3.6.1.4.1.23304.2.2.2.2.1
Gets to 1 when PA is on. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..1  

buc2TxPower 1.3.6.1.4.1.23304.2.2.2.2.2
Gets Tx power format x.x dB. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2TxBurstPower 1.3.6.1.4.1.23304.2.2.2.2.3
Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Faults 1.3.6.1.4.1.23304.2.2.2.2.4
Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2LatchedFaults 1.3.6.1.4.1.23304.2.2.2.2.5
Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER  

buc2Temperature 1.3.6.1.4.1.23304.2.2.2.2.6
Gets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2MinMaxTemperature 1.3.6.1.4.1.23304.2.2.2.2.7
Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2SystemSetting 1.3.6.1.4.1.23304.2.2.2.2.8
Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..2047  

buc2SystemPoll 1.3.6.1.4.1.23304.2.2.2.2.9
Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.
OBJECT-TYPE    
  INTEGER 0..3  

buc2DeviceType 1.3.6.1.4.1.23304.2.2.2.2.10
Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Gateway 1.3.6.1.4.1.23304.2.2.2.2.11
Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2IpAddress 1.3.6.1.4.1.23304.2.2.2.2.12
Gets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2MACAddress 1.3.6.1.4.1.23304.2.2.2.2.13
Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Netmask 1.3.6.1.4.1.23304.2.2.2.2.14
Gets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2RefPower 1.3.6.1.4.1.23304.2.2.2.2.15
Gets the BUC reference power. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Config 1.3.6.1.4.1.23304.2.2.2.2.16
Gets the BUC configuration. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2BuildStandard 1.3.6.1.4.1.23304.2.2.2.2.17
Gets the BUC build standard. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Info 1.3.6.1.4.1.23304.2.2.2.3
OBJECT IDENTIFIER    

buc2IdInfo 1.3.6.1.4.1.23304.2.2.2.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2Limits 1.3.6.1.4.1.23304.2.2.2.3.2
Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

buc2PktProtocolsInfo 1.3.6.1.4.1.23304.2.2.2.3.3
Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.
OBJECT-TYPE    
  DisplayString  

ctrl 1.3.6.1.4.1.23304.2.2.3
OBJECT IDENTIFIER    

settings 1.3.6.1.4.1.23304.2.2.3.1
OBJECT IDENTIFIER    

operationalMode 1.3.6.1.4.1.23304.2.2.3.1.1
Sets 7586 operational mode - Auto, Manual Stream1, Stream2.
OBJECT-TYPE    
  INTEGER 0..2  

onlineStream 1.3.6.1.4.1.23304.2.2.3.1.2
Sets the online stream.
OBJECT-TYPE    
  INTEGER 1..2  

waveguideSwitch 1.3.6.1.4.1.23304.2.2.3.1.3
Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.
OBJECT-TYPE    
  INTEGER 0..2  

startupTime 1.3.6.1.4.1.23304.2.2.3.1.4
Sets Startup time.
OBJECT-TYPE    
  INTEGER 0..50  

lnbCurrentLimit 1.3.6.1.4.1.23304.2.2.3.1.5
Sets LNB current limits.
OBJECT-TYPE    
  DisplayString  

ledState 1.3.6.1.4.1.23304.2.2.3.1.6
Sets 7586 LED.
OBJECT-TYPE    
  INTEGER 0..1  

refSource 1.3.6.1.4.1.23304.2.2.3.1.7
Sets 7586 reference state.
OBJECT-TYPE    
  INTEGER 0..3  

refTrim 1.3.6.1.4.1.23304.2.2.3.1.8
Sets 7586 reference trim.
OBJECT-TYPE    
  DisplayString  

refThresh 1.3.6.1.4.1.23304.2.2.3.1.9
Sets 7586 reference alarm treshold.
OBJECT-TYPE    
  DisplayString  

refPwr 1.3.6.1.4.1.23304.2.2.3.1.10
Gets 7586 reference power.
OBJECT-TYPE    
  DisplayString  

ipAddr 1.3.6.1.4.1.23304.2.2.3.1.11
Gets the 7586 IP address.
OBJECT-TYPE    
  DisplayString  

macAddress 1.3.6.1.4.1.23304.2.2.3.1.12
Gets the 7586 MAC address.
OBJECT-TYPE    
  DisplayString  

netmask 1.3.6.1.4.1.23304.2.2.3.1.13
Gets the 7586 netmask.
OBJECT-TYPE    
  DisplayString  

gateway 1.3.6.1.4.1.23304.2.2.3.1.14
Gets the 7586 gateway address.
OBJECT-TYPE    
  DisplayString  

status 1.3.6.1.4.1.23304.2.2.3.2
OBJECT IDENTIFIER    

lnbCurrent 1.3.6.1.4.1.23304.2.2.3.2.1
Sets 7586 LNB current.
OBJECT-TYPE    
  DisplayString  

lnbVoltage 1.3.6.1.4.1.23304.2.2.3.2.2
Sets 7586 LNB voltage.
OBJECT-TYPE    
  DisplayString  

faults 1.3.6.1.4.1.23304.2.2.3.2.3
Gets the current fault status.
OBJECT-TYPE    
  INTEGER  

info 1.3.6.1.4.1.23304.2.2.3.3
OBJECT IDENTIFIER    

idInfo 1.3.6.1.4.1.23304.2.2.3.3.1
Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.
OBJECT-TYPE    
  DisplayString  

Defined Objects

ComponentRevision  
The hex value in the first octet - xx - represents the major revision no. and the hex value in the second octet - yy - represents the minor revision no.
TEXTUAL-CONVENTION    
  DisplayString SIZE(2)  

FaultStatus7586  
Describes all the possible faults in the system as a bit pattern.
TEXTUAL-CONVENTION    
  BITS dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9)