| RFC-1212 | RFC-1215 | RFC1155-SMI |
| RFC1213-MIB |
| OBJECT-TYPE | TRAP-TYPE | enterprises |
| DisplayString |
| netgear | 1.3.6.1.4.1.4526 | ||
| OBJECT IDENTIFIER | |||
| nasManager | 1.3.6.1.4.1.4526.18 | ||
| OBJECT IDENTIFIER | |||
| nasMgrSoftwareVersion | 1.3.6.1.4.1.4526.18.1 | ||
| Version information for the ReadyNAS NAS Manager software. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..32) | ||
| diskTable | 1.3.6.1.4.1.4526.18.3 | ||
| A table of physical disks attached to the NAS device. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| DiskEntry | |||
| diskEntry | 1.3.6.1.4.1.4526.18.3.1 | ||
| An entry in the physical disk table. | |||
| OBJECT-TYPE | |||
| DiskEntry | |||
| diskNumber | 1.3.6.1.4.1.4526.18.3.1.1 | ||
| Instance number of the disk entry. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| diskChannel | 1.3.6.1.4.1.4526.18.3.1.2 | ||
| Channel number that the disk is connected to. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| diskModel | 1.3.6.1.4.1.4526.18.3.1.3 | ||
| The disk drive's model name. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| diskState | 1.3.6.1.4.1.4526.18.3.1.4 | ||
| The current state of the Disk. Possible states: 0: Online 1: Offline | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| diskTemperature | 1.3.6.1.4.1.4526.18.3.1.5 | ||
| temperature of this disk. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| fanTable | 1.3.6.1.4.1.4526.18.4 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| FanEntry | |||
| fanEntry | 1.3.6.1.4.1.4526.18.4.1 | ||
| OBJECT-TYPE | |||
| FanEntry | |||
| fanNumber | 1.3.6.1.4.1.4526.18.4.1.1 | ||
| Instance number of this fan entry. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..10000000 | ||
| fanRPM | 1.3.6.1.4.1.4526.18.4.1.2 | ||
| The current speed of the fan. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| temperatureTable | 1.3.6.1.4.1.4526.18.5 | ||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| TemperatureEntry | |||
| temperatureEntry | 1.3.6.1.4.1.4526.18.5.1 | ||
| OBJECT-TYPE | |||
| TemperatureEntry | |||
| temperatureNumber | 1.3.6.1.4.1.4526.18.5.1.1 | ||
| Instance number of this temperature probe entry. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| temperatureValue | 1.3.6.1.4.1.4526.18.5.1.2 | ||
| The current temperature of this probe. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| temperatureStatus | 1.3.6.1.4.1.4526.18.5.1.3 | ||
| The current temperature status. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| volumeTable | 1.3.6.1.4.1.4526.18.7 | ||
| A table of active volumes on the NAS device. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| VolumeEntry | |||
| volumeEntry | 1.3.6.1.4.1.4526.18.7.1 | ||
| An entry in the volume table. | |||
| OBJECT-TYPE | |||
| VolumeEntry | |||
| volumeNumber | 1.3.6.1.4.1.4526.18.7.1.1 | ||
| Instance number of the volume entry. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| volumeName | 1.3.6.1.4.1.4526.18.7.1.2 | ||
| The name of the volume. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| volumeRAIDLevel | 1.3.6.1.4.1.4526.18.7.1.3 | ||
| The RAID level of the volume. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| volumeStatus | 1.3.6.1.4.1.4526.18.7.1.4 | ||
| The severity of the volume. Possible values: 1: Clean 2: Error 16: Initialized (Normal) | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| volumeSize | 1.3.6.1.4.1.4526.18.7.1.5 | ||
| The size of the volume in megabytes. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| volumeFreeSpace | 1.3.6.1.4.1.4526.18.7.1.6 | ||
| Free space on the volume in megabytes. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| aryMgrEvts | 1.3.6.1.4.1.4526.18.200 | ||
| OBJECT IDENTIFIER | |||
| controllerNameEv | 1.3.6.1.4.1.4526.18.200.201 | ||
| Controller Name for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..64) | ||
| channelNumberEv | 1.3.6.1.4.1.4526.18.200.202 | ||
| Channel Number for which trap is generated. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..3 | ||
| targetIDEv | 1.3.6.1.4.1.4526.18.200.203 | ||
| SCSI ID of the device for which trap is generated. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..15 | ||
| virtualDiskNameEv | 1.3.6.1.4.1.4526.18.200.204 | ||
| Virtual Disk for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..64) | ||
| arrayDiskNameEv | 1.3.6.1.4.1.4526.18.200.205 | ||
| Array Disk for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..64) | ||
| oldVDConfigEv | 1.3.6.1.4.1.4526.18.200.206 | ||
| Current Virtual Disk configuration for which trap is generated | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..128) | ||
| newVDConfigEv | 1.3.6.1.4.1.4526.18.200.207 | ||
| New Virtual Disk configuration for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(1..128) | ||
| enclosureNumberEv | 1.3.6.1.4.1.4526.18.200.208 | ||
| Enclosure Number for which trap is generated. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unitNumberEv | 1.3.6.1.4.1.4526.18.200.209 | ||
| Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| enclosureNameEv | 1.3.6.1.4.1.4526.18.200.210 | ||
| Enclosure Name for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| unitNameEv | 1.3.6.1.4.1.4526.18.200.211 | ||
| Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| timeEv | 1.3.6.1.4.1.4526.18.200.212 | ||
| Amount of time specified in the trap message. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| volumeNameEv | 1.3.6.1.4.1.4526.18.200.213 | ||
| Volume Drive Letter for which trap is generated. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| nasTraps | 1.3.6.1.4.1.4526.18.300 | ||
| OBJECT IDENTIFIER | |||
| fanFailure | 1.3.6.1.4.1.4526.18.300.10 | ||
| Fan failure, fan speed is %s. | |||
| TRAP-TYPE | |||
| fanFailureMesg | |||
| tempFailure | 1.3.6.1.4.1.4526.18.300.20 | ||
| Temperature sensor reports out of normal range. | |||
| TRAP-TYPE | |||
| tempFailureMesg | |||
| powerVoltage | 1.3.6.1.4.1.4526.18.300.30 | ||
| System power is out of spec, please check system status! | |||
| TRAP-TYPE | |||
| powerFailureMesg | |||
| raidEventNotice | 1.3.6.1.4.1.4526.18.300.40 | ||
| RAID event detected! | |||
| TRAP-TYPE | |||
| raidMesg | |||
| snapshotEventNotice | 1.3.6.1.4.1.4526.18.300.50 | ||
| Snapshot event detected! | |||
| TRAP-TYPE | |||
| snapshotMesg | |||
| hotplugDiskNotice | 1.3.6.1.4.1.4526.18.300.60 | ||
| Hotplug disk event detected! | |||
| TRAP-TYPE | |||
| sataMesg | |||
| upsEventNotice | 1.3.6.1.4.1.4526.18.300.70 | ||
| UPS status. | |||
| TRAP-TYPE | |||
| upsMesg | |||
| volumeNotice | 1.3.6.1.4.1.4526.18.300.80 | ||
| Volume is approaching capacity. | |||
| TRAP-TYPE | |||
| volumeMesg | |||
| diskTempWarning | 1.3.6.1.4.1.4526.18.300.90 | ||
| Disk temperature warning. | |||
| TRAP-TYPE | |||
| volumeMesg | |||
| backupNotice | 1.3.6.1.4.1.4526.18.300.100 | ||
| Backup job status. | |||
| TRAP-TYPE | |||
| backupMesg | |||
| fanFailureMesg | 1.3.6.1.4.1.4526.18.400 | ||
| Failure message for Fan | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| tempFailureMesg | 1.3.6.1.4.1.4526.18.401 | ||
| Failure message for system temperature | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| powerFailureMesg | 1.3.6.1.4.1.4526.18.402 | ||
| Failure message for system power | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| raidMesg | 1.3.6.1.4.1.4526.18.403 | ||
| RAID hotplug event message | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| snapshotMesg | 1.3.6.1.4.1.4526.18.404 | ||
| Snapshot messages | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| upsMesg | 1.3.6.1.4.1.4526.18.405 | ||
| UPS status message | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| sataMesg | 1.3.6.1.4.1.4526.18.406 | ||
| SATA hotplug event messages | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| volumeMesg | 1.3.6.1.4.1.4526.18.407 | ||
| Disk usage warning | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| diskTempWarningMesg | 1.3.6.1.4.1.4526.18.408 | ||
| Disk temperature warning messages | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| backupMesg | 1.3.6.1.4.1.4526.18.409 | ||
| Backup job status messages | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| productID | 1.3.6.1.4.1.4526.100 | ||
| OBJECT IDENTIFIER | |||
| readyNAS | 1.3.6.1.4.1.4526.100.12 | ||
| OBJECT IDENTIFIER | |||
| DiskEntry | |||
| SEQUENCE | |||
| INTEGER as diskNumber | |||
| INTEGER as diskChannel | |||
| DisplayString as diskModel | |||
| DisplayString as diskState | |||
| DisplayString as diskTemperature | |||
| FanEntry | |||
| SEQUENCE | |||
| INTEGER as fanNumber | |||
| INTEGER as fanRPM | |||
| TemperatureEntry | |||
| SEQUENCE | |||
| INTEGER as temperatureNumber | |||
| DisplayString as temperatureValue | |||
| DisplayString as temperatureStatus | |||
| VolumeEntry | |||
| SEQUENCE | |||
| INTEGER as volumeNumber | |||
| DisplayString as volumeName | |||
| DisplayString as volumeRAIDLevel | |||
| DisplayString as volumeStatus | |||
| INTEGER as volumeSize | |||
| INTEGER as volumeFreeSpace | |||