RFC1317-MIB

File: RFC1317-MIB.mib (19260 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

Counter transmission OBJECT-TYPE

Defined Objects

rs232 1.3.6.1.2.1.10.33
OBJECT IDENTIFIER    

rs232Number 1.3.6.1.2.1.10.33.1
The number of ports (regardless of their current state) in the RS-232-like general port table.
OBJECT-TYPE    
  INTEGER  

rs232PortTable 1.3.6.1.2.1.10.33.2
A list of port entries. The number of entries is given by the value of rs232Number.
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232PortEntry

rs232PortEntry 1.3.6.1.2.1.10.33.2.1
Status and parameter values for a port.
OBJECT-TYPE    
  Rs232PortEntry  

rs232PortIndex 1.3.6.1.2.1.10.33.2.1.1
A unique value for each port. Its value ranges between 1 and the value of rs232Number. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next.
OBJECT-TYPE    
  INTEGER  

rs232PortType 1.3.6.1.2.1.10.33.2.1.2
The port's hardware type.
OBJECT-TYPE    
  INTEGER other(1), rs232(2), rs422(3), rs423(4), v35(5)  

rs232PortInSigNumber 1.3.6.1.2.1.10.33.2.1.3
The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect.
OBJECT-TYPE    
  INTEGER  

rs232PortOutSigNumber 1.3.6.1.2.1.10.33.2.1.4
The number of output signals for the port in the output signal table (rs232PortOutSigTable). The table contains entries only for those signals the software can assert.
OBJECT-TYPE    
  INTEGER  

rs232PortInSpeed 1.3.6.1.2.1.10.33.2.1.5
The port's input speed in bits per second.
OBJECT-TYPE    
  INTEGER  

rs232PortOutSpeed 1.3.6.1.2.1.10.33.2.1.6
The port's output speed in bits per second.
OBJECT-TYPE    
  INTEGER  

rs232AsyncPortTable 1.3.6.1.2.1.10.33.3
A list of asynchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for synchronous ports.
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232AsyncPortEntry

rs232AsyncPortEntry 1.3.6.1.2.1.10.33.3.1
Status and parameter values for an asynchronous port.
OBJECT-TYPE    
  Rs232AsyncPortEntry  

rs232AsyncPortIndex 1.3.6.1.2.1.10.33.3.1.1
A unique value for each port. Its value is the same as rs232PortIndex for the port.
OBJECT-TYPE    
  INTEGER  

rs232AsyncPortBits 1.3.6.1.2.1.10.33.3.1.2
The port's number of bits in a character.
OBJECT-TYPE    
  INTEGER 5..8  

rs232AsyncPortStopBits 1.3.6.1.2.1.10.33.3.1.3
The port's number of stop bits.
OBJECT-TYPE    
  INTEGER one(1), two(2), one-and-half(3), dynamic(4)  

rs232AsyncPortParity 1.3.6.1.2.1.10.33.3.1.4
The port's sense of a character parity bit.
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3), mark(4), space(5)  

rs232AsyncPortAutobaud 1.3.6.1.2.1.10.33.3.1.5
A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set.
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

rs232AsyncPortParityErrs 1.3.6.1.2.1.10.33.3.1.6
Total number of characters with a parity error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232AsyncPortFramingErrs 1.3.6.1.2.1.10.33.3.1.7
Total number of characters with a framing error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232AsyncPortOverrunErrs 1.3.6.1.2.1.10.33.3.1.8
Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232SyncPortTable 1.3.6.1.2.1.10.33.4
A list of synchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for asynchronous ports.
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232SyncPortEntry

rs232SyncPortEntry 1.3.6.1.2.1.10.33.4.1
Status and parameter values for a synchronous port.
OBJECT-TYPE    
  Rs232SyncPortEntry  

rs232SyncPortIndex 1.3.6.1.2.1.10.33.4.1.1
A unique value for each port. Its value is the same as rs232PortIndex for the port.
OBJECT-TYPE    
  INTEGER  

rs232SyncPortClockSource 1.3.6.1.2.1.10.33.4.1.2
Source of the port's bit rate clock. 'split' means the tranmit clock is internal and the receive clock is external.
OBJECT-TYPE    
  INTEGER internal(1), external(2), split(3)  

rs232SyncPortFrameCheckErrs 1.3.6.1.2.1.10.33.4.1.3
Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232SyncPortTransmitUnderrunErrs 1.3.6.1.2.1.10.33.4.1.4
Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time.
OBJECT-TYPE    
  Counter  

rs232SyncPortReceiveOverrunErrs 1.3.6.1.2.1.10.33.4.1.5
Total number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver did not accept the data in time.
OBJECT-TYPE    
  Counter  

rs232SyncPortInterruptedFrames 1.3.6.1.2.1.10.33.4.1.6
Total number of frames that failed to be received or transmitted on the port due to loss of modem signals since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232SyncPortAbortedFrames 1.3.6.1.2.1.10.33.4.1.7
Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'.
OBJECT-TYPE    
  Counter  

rs232InSigTable 1.3.6.1.2.1.10.33.5
A list of port input control signal entries.
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232InSigEntry

rs232InSigEntry 1.3.6.1.2.1.10.33.5.1
Input control signal status for a hardware port.
OBJECT-TYPE    
  Rs232InSigEntry  

rs232InSigPortIndex 1.3.6.1.2.1.10.33.5.1.1
The value of rs232PortIndex for the port to which this entry belongs.
OBJECT-TYPE    
  INTEGER  

rs232InSigName 1.3.6.1.2.1.10.33.5.1.2
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector
OBJECT-TYPE    
  INTEGER rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)  

rs232InSigState 1.3.6.1.2.1.10.33.5.1.3
The current signal state.
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

rs232InSigChanges 1.3.6.1.2.1.10.33.5.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
OBJECT-TYPE    
  Counter  

rs232OutSigTable 1.3.6.1.2.1.10.33.6
A list of port output control signal entries.
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232OutSigEntry

rs232OutSigEntry 1.3.6.1.2.1.10.33.6.1
Output control signal status for a hardware port.
OBJECT-TYPE    
  Rs232OutSigEntry  

rs232OutSigPortIndex 1.3.6.1.2.1.10.33.6.1.1
The value of rs232PortIndex for the port to which this entry belongs.
OBJECT-TYPE    
  INTEGER  

rs232OutSigName 1.3.6.1.2.1.10.33.6.1.2
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector
OBJECT-TYPE    
  INTEGER rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)  

rs232OutSigState 1.3.6.1.2.1.10.33.6.1.3
The current signal state.
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

rs232OutSigChanges 1.3.6.1.2.1.10.33.6.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
OBJECT-TYPE    
  Counter  

Defined Objects

Rs232PortEntry  
SEQUENCE    
  INTEGER as rs232PortIndex  
  INTEGER as rs232PortType  
  INTEGER as rs232PortInSigNumber  
  INTEGER as rs232PortOutSigNumber  
  INTEGER as rs232PortInSpeed  
  INTEGER as rs232PortOutSpeed  

Rs232AsyncPortEntry  
SEQUENCE    
  INTEGER as rs232AsyncPortIndex  
  INTEGER as rs232AsyncPortBits  
  INTEGER as rs232AsyncPortStopBits  
  INTEGER as rs232AsyncPortParity  
  INTEGER as rs232AsyncPortAutobaud  
  Counter as rs232AsyncPortParityErrs  
  Counter as rs232AsyncPortFramingErrs  
  Counter as rs232AsyncPortOverrunErrs  

Rs232SyncPortEntry  
SEQUENCE    
  INTEGER as rs232SyncPortIndex  
  INTEGER as rs232SyncPortClockSource  
  Counter as rs232SyncPortFrameCheckErrs  
  Counter as rs232SyncPortTransmitUnderrunErrs  
  Counter as rs232SyncPortReceiveOverrunErrs  
  Counter as rs232SyncPortInterruptedFrames  
  Counter as rs232SyncPortAbortedFrames  

Rs232InSigEntry  
SEQUENCE    
  INTEGER as rs232InSigPortIndex  
  INTEGER as rs232InSigName  
  INTEGER as rs232InSigState  
  Counter as rs232InSigChanges  

Rs232OutSigEntry  
SEQUENCE    
  INTEGER as rs232OutSigPortIndex  
  INTEGER as rs232OutSigName  
  INTEGER as rs232OutSigState  
  Counter as rs232OutSigChanges