RFC1318-MIB

File: RFC1318-MIB.mib (9145 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

Counter transmission OBJECT-TYPE

Defined Objects

para 1.3.6.1.2.1.10.34
OBJECT IDENTIFIER    

paraNumber 1.3.6.1.2.1.10.34.1
The number of ports (regardless of their current state) in the Parallel-printer-like port table.
OBJECT-TYPE    
  INTEGER  

paraPortTable 1.3.6.1.2.1.10.34.2
A list of port entries. The number of entries is given by the value of paraNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    ParaPortEntry

paraPortEntry 1.3.6.1.2.1.10.34.2.1
Status and parameter values for a port.
OBJECT-TYPE    
  ParaPortEntry  

paraPortIndex 1.3.6.1.2.1.10.34.2.1.1
A unique value for each port. Its value ranges between 1 and the value of paraNumber. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next.
OBJECT-TYPE    
  INTEGER  

paraPortType 1.3.6.1.2.1.10.34.2.1.2
The port's hardware type.
OBJECT-TYPE    
  INTEGER other(1), centronics(2), dataproducts(3)  

paraPortInSigNumber 1.3.6.1.2.1.10.34.2.1.3
The number of input signals for the port in the input signal table (paraPortInSigTable). The table contains entries only for those signals the software can detect.
OBJECT-TYPE    
  INTEGER  

paraPortOutSigNumber 1.3.6.1.2.1.10.34.2.1.4
The number of output signals for the port in the output signal table (paraPortOutSigTable). The table contains entries only for those signals the software can assert.
OBJECT-TYPE    
  INTEGER  

paraInSigTable 1.3.6.1.2.1.10.34.3
A list of port input control signal entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ParaInSigEntry

paraInSigEntry 1.3.6.1.2.1.10.34.3.1
Input control signal status for a hardware port.
OBJECT-TYPE    
  ParaInSigEntry  

paraInSigPortIndex 1.3.6.1.2.1.10.34.3.1.1
The value of paraPortIndex for the port to which this entry belongs.
OBJECT-TYPE    
  INTEGER  

paraInSigName 1.3.6.1.2.1.10.34.3.1.2
Identification of a hardware signal.
OBJECT-TYPE    
  INTEGER power(1), online(2), busy(3), paperout(4), fault(5)  

paraInSigState 1.3.6.1.2.1.10.34.3.1.3
The current signal state.
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

paraInSigChanges 1.3.6.1.2.1.10.34.3.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
OBJECT-TYPE    
  Counter  

paraOutSigTable 1.3.6.1.2.1.10.34.4
A list of port output control signal entries.
OBJECT-TYPE    
  SEQUENCE OF  
    ParaOutSigEntry

paraOutSigEntry 1.3.6.1.2.1.10.34.4.1
Output control signal status for a hardware port.
OBJECT-TYPE    
  ParaOutSigEntry  

paraOutSigPortIndex 1.3.6.1.2.1.10.34.4.1.1
The value of paraPortIndex for the port to which this entry belongs.
OBJECT-TYPE    
  INTEGER  

paraOutSigName 1.3.6.1.2.1.10.34.4.1.2
Identification of a hardware signal.
OBJECT-TYPE    
  INTEGER power(1), online(2), busy(3), paperout(4), fault(5)  

paraOutSigState 1.3.6.1.2.1.10.34.4.1.3
The current signal state.
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

paraOutSigChanges 1.3.6.1.2.1.10.34.4.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
OBJECT-TYPE    
  Counter  

Defined Objects

ParaPortEntry  
SEQUENCE    
  INTEGER as paraPortIndex  
  INTEGER as paraPortType  
  INTEGER as paraPortInSigNumber  
  INTEGER as paraPortOutSigNumber  

ParaInSigEntry  
SEQUENCE    
  INTEGER as paraInSigPortIndex  
  INTEGER as paraInSigName  
  INTEGER as paraInSigState  
  Counter as paraInSigChanges  

ParaOutSigEntry  
SEQUENCE    
  INTEGER as paraOutSigPortIndex  
  INTEGER as paraOutSigName  
  INTEGER as paraOutSigState  
  Counter as paraOutSigChanges