| RFC1155-SMI | RFC1213-MIB | RFC-1212 |
| RFC-1215 |
| enterprises | DisplayString | sysName |
| sysDescr | sysContact | sysLocation |
| OBJECT-TYPE | TRAP-TYPE |
| rittal | 1.3.6.1.4.1.2606 | ||
| OBJECT IDENTIFIER | |||
| cmcTc | 1.3.6.1.4.1.2606.4 | ||
| OBJECT IDENTIFIER | |||
| cmcTcMibRev | 1.3.6.1.4.1.2606.4.1 | ||
| OBJECT IDENTIFIER | |||
| alarmSensorUnit1 | 1.3.6.1.4.1.2606.4.1 | ||
| Alarm of Sensor unit 1 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| unit1MsgIndex | |||
| unit1MsgText | |||
| unit1MsgStatus | |||
| unit1SensorValue | |||
| cmcTcMibMajRev | 1.3.6.1.4.1.2606.4.1.1 | ||
| The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| cmcTcMibMinRev | 1.3.6.1.4.1.2606.4.1.2 | ||
| The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..65535 | ||
| cmcTcMibCondition | 1.3.6.1.4.1.2606.4.1.3 | ||
| The overall condition (status) of the system represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC) (5) configuration of sensor units changed or unit detected (red/yellow/green LED on CMC) | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), ok(2), degraded(3), failed(4), configChanged(5) | ||
| cmcTcStatus | 1.3.6.1.4.1.2606.4.2 | ||
| OBJECT IDENTIFIER | |||
| alarmSensorUnit2 | 1.3.6.1.4.1.2606.4.2 | ||
| Alarm of sensor unit 2 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| unit2MsgIndex | |||
| unit2MsgText | |||
| unit2MsgStatus | |||
| unit2SensorValue | |||
| cmcTcStatusDeviceCMC | 1.3.6.1.4.1.2606.4.2.1 | ||
| General Status of CMC-TC unit itself (1) failed (2) OK | |||
| OBJECT-TYPE | |||
| INTEGER | failed(1), ok(2) | ||
| cmcTcUnitsConnected | 1.3.6.1.4.1.2606.4.2.2 | ||
| Number of sensor units connected to the CMC, Port 1 to 4 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcStatusSensorUnit1 | 1.3.6.1.4.1.2606.4.2.3 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit1TypeOfDevice | 1.3.6.1.4.1.2606.4.2.3.1 | ||
| Type of sensor unit connected to port 1 | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6) | ||
| cmcTcUnit1Text | 1.3.6.1.4.1.2606.4.2.3.2 | ||
| Descriptional text for sensor unit connected to port 1 | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| cmcTcUnit1Serial | 1.3.6.1.4.1.2606.4.2.3.3 | ||
| Serialnumber of sensor unit connected to port 1 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit1Status | 1.3.6.1.4.1.2606.4.2.3.4 | ||
| General Status sensor unit connected to port 1 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8) | ||
| cmcTcStatusUnit1Sensors | 1.3.6.1.4.1.2606.4.2.3.5 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit1NumberOfSensors | 1.3.6.1.4.1.2606.4.2.3.5.1 | ||
| Number of sensors connected to sensor unit 1 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit1SensorTable | 1.3.6.1.4.1.2606.4.2.3.5.2 | ||
| Headline of sensor table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit1SensorEntry | |||
| cmcTcUnit1SensorEntry | 1.3.6.1.4.1.2606.4.2.3.5.2.1 | ||
| Entries of sensor table | |||
| OBJECT-TYPE | |||
| CmcTcUnit1SensorEntry | |||
| unit1SensorIndex | 1.3.6.1.4.1.2606.4.2.3.5.2.1.1 | ||
| Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfSensors. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit1SensorType | 1.3.6.1.4.1.2606.4.2.3.5.2.1.2 | ||
| Type of sensor which is connected to sensor unit 1 to sensor[unit1SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage (OK, NOK) 18: voltage value 19: fan status, from CMC-TC-FAS-Unit 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26) | ||
| unit1SensorText | 1.3.6.1.4.1.2606.4.2.3.5.2.1.3 | ||
| Descriptional text for each sensor (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit1SensorStatus | 1.3.6.1.4.1.2606.4.2.3.5.2.1.4 | ||
| Actual status of the sensor | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9) | ||
| unit1SensorValue | 1.3.6.1.4.1.2606.4.2.3.5.2.1.5 | ||
| Value of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit1SensorSetHigh | 1.3.6.1.4.1.2606.4.2.3.5.2.1.6 | ||
| Value for high setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit1SensorSetLow | 1.3.6.1.4.1.2606.4.2.3.5.2.1.7 | ||
| Value for low setpoint of sensor, also used as alarm delay | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit1SensorSetWarn | 1.3.6.1.4.1.2606.4.2.3.5.2.1.8 | ||
| Value for warning setpoint of sensor, also used as fan threshold | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcStatusUnit1Outputs | 1.3.6.1.4.1.2606.4.2.3.6 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit1NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.3.6.1 | ||
| Number of outputs available on sensor unit 1 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit1OutputTable | 1.3.6.1.4.1.2606.4.2.3.6.2 | ||
| Headline of output table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit1OutputEntry | |||
| cmcTcUnit1OutputEntry | 1.3.6.1.4.1.2606.4.2.3.6.2.1 | ||
| Entries of output table | |||
| OBJECT-TYPE | |||
| CmcTcUnit1OutputEntry | |||
| unit1OutputIndex | 1.3.6.1.4.1.2606.4.2.3.6.2.1.1 | ||
| Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfOutputs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit1OutputType | 1.3.6.1.4.1.2606.4.2.3.6.2.1.2 | ||
| Type of output which is connected to sensor unit 1 to output[unit1OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15) | ||
| unit1OutputText | 1.3.6.1.4.1.2606.4.2.3.6.2.1.3 | ||
| Descriptional text for each output (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit1OutputStatus | 1.3.6.1.4.1.2606.4.2.3.6.2.1.4 | ||
| Actual status of the output | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8) | ||
| unit1OutputValue | 1.3.6.1.4.1.2606.4.2.3.6.2.1.5 | ||
| Value for output | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit1OutputSet | 1.3.6.1.4.1.2606.4.2.3.6.2.1.6 | ||
| Command for output | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), lock(3), unlock(4), unlockDelay(5) | ||
| unit1OutputConfig | 1.3.6.1.4.1.2606.4.2.3.6.2.1.7 | ||
| Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control | |||
| OBJECT-TYPE | |||
| INTEGER | disRemote(1), enRemote(2) | ||
| unit1OutputDelay | 1.3.6.1.4.1.2606.4.2.3.6.2.1.8 | ||
| Unsigned Value for delay, after this time the output will fall into the previous state | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit1OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.3.6.2.1.9 | ||
| State for output if timeout (RS422) occurs | |||
| OBJECT-TYPE | |||
| INTEGER | stay(1), off(2), on(3) | ||
| cmcTcStatusUnit1Msg | 1.3.6.1.4.1.2606.4.2.3.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit1NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.3.7.1 | ||
| Number of messages that can be created with sensor unit 1 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit1MsgTable | 1.3.6.1.4.1.2606.4.2.3.7.2 | ||
| Headline of message table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit1MsgEntry | |||
| cmcTcUnit1MsgEntry | 1.3.6.1.4.1.2606.4.2.3.7.2.1 | ||
| Entries of message table | |||
| OBJECT-TYPE | |||
| CmcTcUnit1MsgEntry | |||
| unit1MsgIndex | 1.3.6.1.4.1.2606.4.2.3.7.2.1.1 | ||
| Index for the list of message entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfMsgs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit1MsgText | 1.3.6.1.4.1.2606.4.2.3.7.2.1.2 | ||
| Descriptional text for each message (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit1MsgStatus | 1.3.6.1.4.1.2606.4.2.3.7.2.1.3 | ||
| Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) | ||
| unit1MsgRelay | 1.3.6.1.4.1.2606.4.2.3.7.2.1.4 | ||
| Setup of Alarm relay for this message/alarm 1: no switching of alarm relay 2: switching of alarm relay | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgBeeper | 1.3.6.1.4.1.2606.4.2.3.7.2.1.5 | ||
| Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgTrap1 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.6 | ||
| Trap receiver 1 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgTrap2 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.7 | ||
| Trap receiver 2 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgTrap3 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.8 | ||
| Trap receiver 3 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgTrap4 | 1.3.6.1.4.1.2606.4.2.3.7.2.1.9 | ||
| Trap receiver 4 and Event Logging activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit1MsgQuit | 1.3.6.1.4.1.2606.4.2.3.7.2.1.10 | ||
| Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key | |||
| OBJECT-TYPE | |||
| INTEGER | auto(1), manual(2) | ||
| cmcTcStatusSensorUnit2 | 1.3.6.1.4.1.2606.4.2.4 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit2TypeOfDevice | 1.3.6.1.4.1.2606.4.2.4.1 | ||
| Type of sensor unit connected to port 2 | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6) | ||
| cmcTcUnit2Text | 1.3.6.1.4.1.2606.4.2.4.2 | ||
| Descriptional text for sensor unit connected to port 2 | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| cmcTcUnit2Serial | 1.3.6.1.4.1.2606.4.2.4.3 | ||
| Serialnumber of sensor unit connected to port 2 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit2Status | 1.3.6.1.4.1.2606.4.2.4.4 | ||
| General Status sensor unit connected to port 2 (1) OK (2) error (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required (6) sensor unit detected, needs to be confirmed (8) supply voltage is too low | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8) | ||
| cmcTcStatusUnit2Sensors | 1.3.6.1.4.1.2606.4.2.4.5 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit2NumberOfSensors | 1.3.6.1.4.1.2606.4.2.4.5.1 | ||
| Number of sensors connected to sensor unit 2 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit2SensorTable | 1.3.6.1.4.1.2606.4.2.4.5.2 | ||
| Headline of sensor table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit2SensorEntry | |||
| cmcTcUnit2SensorEntry | 1.3.6.1.4.1.2606.4.2.4.5.2.1 | ||
| Entries of sensor table | |||
| OBJECT-TYPE | |||
| CmcTcUnit2SensorEntry | |||
| unit2SensorIndex | 1.3.6.1.4.1.2606.4.2.4.5.2.1.1 | ||
| Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfSensors. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit2SensorType | 1.3.6.1.4.1.2606.4.2.4.5.2.1.2 | ||
| Type of sensor which is connected to sensor unit 2 to sensor[unit2SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26) | ||
| unit2SensorText | 1.3.6.1.4.1.2606.4.2.4.5.2.1.3 | ||
| Descriptional text for each sensor (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit2SensorStatus | 1.3.6.1.4.1.2606.4.2.4.5.2.1.4 | ||
| Actual status of the sensor | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9) | ||
| unit2SensorValue | 1.3.6.1.4.1.2606.4.2.4.5.2.1.5 | ||
| Value of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit2SensorSetHigh | 1.3.6.1.4.1.2606.4.2.4.5.2.1.6 | ||
| Value for high setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit2SensorSetLow | 1.3.6.1.4.1.2606.4.2.4.5.2.1.7 | ||
| Value for low setpoint of sensor, also used as alarm delay | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit2SensorSetWarn | 1.3.6.1.4.1.2606.4.2.4.5.2.1.8 | ||
| Value for warning setpoint of sensor, also used as fan threshold | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcStatusUnit2Outputs | 1.3.6.1.4.1.2606.4.2.4.6 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit2NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.4.6.1 | ||
| Number of outputs available on sensor unit 2 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit2OutputTable | 1.3.6.1.4.1.2606.4.2.4.6.2 | ||
| Headline of output table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit2OutputEntry | |||
| cmcTcUnit2OutputEntry | 1.3.6.1.4.1.2606.4.2.4.6.2.1 | ||
| Entries of output table | |||
| OBJECT-TYPE | |||
| CmcTcUnit2OutputEntry | |||
| unit2OutputIndex | 1.3.6.1.4.1.2606.4.2.4.6.2.1.1 | ||
| Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfOutputs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit2OutputType | 1.3.6.1.4.1.2606.4.2.4.6.2.1.2 | ||
| Type of output which is connected to sensor unit 2 to output[unit2OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15) | ||
| unit2OutputText | 1.3.6.1.4.1.2606.4.2.4.6.2.1.3 | ||
| Descriptional text for each output (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit2OutputStatus | 1.3.6.1.4.1.2606.4.2.4.6.2.1.4 | ||
| Actual status of the output | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8) | ||
| unit2OutputValue | 1.3.6.1.4.1.2606.4.2.4.6.2.1.5 | ||
| Signed value for output | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit2OutputSet | 1.3.6.1.4.1.2606.4.2.4.6.2.1.6 | ||
| Command for output | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), lock(3), unlock(4), unlockDelay(5) | ||
| unit2OutputConfig | 1.3.6.1.4.1.2606.4.2.4.6.2.1.7 | ||
| Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control | |||
| OBJECT-TYPE | |||
| INTEGER | disRemote(1), enRemote(2) | ||
| unit2OutputDelay | 1.3.6.1.4.1.2606.4.2.4.6.2.1.8 | ||
| Unsigned Value for delay, after this time the output will fall into the previous state | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit2OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.4.6.2.1.9 | ||
| State for output if timeout (RS422) occurs | |||
| OBJECT-TYPE | |||
| INTEGER | stay(1), off(2), on(3) | ||
| cmcTcStatusUnit2Msg | 1.3.6.1.4.1.2606.4.2.4.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit2NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.4.7.1 | ||
| Number of alarms that can be created with sensor unit 2 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit2MsgTable | 1.3.6.1.4.1.2606.4.2.4.7.2 | ||
| Headline of message table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit2MsgEntry | |||
| cmcTcUnit2MsgEntry | 1.3.6.1.4.1.2606.4.2.4.7.2.1 | ||
| Entries of message table | |||
| OBJECT-TYPE | |||
| CmcTcUnit2MsgEntry | |||
| unit2MsgIndex | 1.3.6.1.4.1.2606.4.2.4.7.2.1.1 | ||
| Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfMsgs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit2MsgText | 1.3.6.1.4.1.2606.4.2.4.7.2.1.2 | ||
| Descriptional text for each message (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit2MsgStatus | 1.3.6.1.4.1.2606.4.2.4.7.2.1.3 | ||
| Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) | ||
| unit2MsgRelay | 1.3.6.1.4.1.2606.4.2.4.7.2.1.4 | ||
| Setup of Alarm relay for this alarm 2: no switching of alarm relay 1: switching of alarm relay | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgBeeper | 1.3.6.1.4.1.2606.4.2.4.7.2.1.5 | ||
| Setup of Alarm beeper for this alarm 2: no audible alarm 1: audible alarm | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgTrap1 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.6 | ||
| Trap receiver 1 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgTrap2 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.7 | ||
| Trap receiver 2 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgTrap3 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.8 | ||
| Trap receiver 3 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgTrap4 | 1.3.6.1.4.1.2606.4.2.4.7.2.1.9 | ||
| Trap receiver 4 and Event Logging activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit2MsgQuit | 1.3.6.1.4.1.2606.4.2.4.7.2.1.10 | ||
| Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key | |||
| OBJECT-TYPE | |||
| INTEGER | auto(1), manual(2) | ||
| cmcTcStatusSensorUnit3 | 1.3.6.1.4.1.2606.4.2.5 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit3TypeOfDevice | 1.3.6.1.4.1.2606.4.2.5.1 | ||
| Type of sensor unit connected to port 3 | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6) | ||
| cmcTcUnit3Text | 1.3.6.1.4.1.2606.4.2.5.2 | ||
| Descriptional text for sensor unit connected to port 3 | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| cmcTcUnit3Serial | 1.3.6.1.4.1.2606.4.2.5.3 | ||
| Serialnumber of sensor unit connected to port 3 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit3Status | 1.3.6.1.4.1.2606.4.2.5.4 | ||
| General Status sensor unit connected to port 3 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8) | ||
| cmcTcStatusUnit3Sensors | 1.3.6.1.4.1.2606.4.2.5.5 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit3NumberOfSensors | 1.3.6.1.4.1.2606.4.2.5.5.1 | ||
| Number of sensors connected to sensor unit 3 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit3SensorTable | 1.3.6.1.4.1.2606.4.2.5.5.2 | ||
| Headline of sensor table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit3SensorEntry | |||
| cmcTcUnit3SensorEntry | 1.3.6.1.4.1.2606.4.2.5.5.2.1 | ||
| Entries of sensor table | |||
| OBJECT-TYPE | |||
| CmcTcUnit3SensorEntry | |||
| unit3SensorIndex | 1.3.6.1.4.1.2606.4.2.5.5.2.1.1 | ||
| Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfSensors. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit3SensorType | 1.3.6.1.4.1.2606.4.2.5.5.2.1.2 | ||
| Type of sensor which is connected to sensor unit 3 to sensor[unit3SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26) | ||
| unit3SensorText | 1.3.6.1.4.1.2606.4.2.5.5.2.1.3 | ||
| Descriptional text for each sensor (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit3SensorStatus | 1.3.6.1.4.1.2606.4.2.5.5.2.1.4 | ||
| Actual status of the sensor | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9) | ||
| unit3SensorValue | 1.3.6.1.4.1.2606.4.2.5.5.2.1.5 | ||
| Value of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit3SensorSetHigh | 1.3.6.1.4.1.2606.4.2.5.5.2.1.6 | ||
| Value for high setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit3SensorSetLow | 1.3.6.1.4.1.2606.4.2.5.5.2.1.7 | ||
| Value for low setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit3SensorSetWarn | 1.3.6.1.4.1.2606.4.2.5.5.2.1.8 | ||
| Value for warning setpoint of sensor, also used as fan threshold | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcStatusUnit3Outputs | 1.3.6.1.4.1.2606.4.2.5.6 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit3NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.5.6.1 | ||
| Number of outputs available on sensor unit 3 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit3OutputTable | 1.3.6.1.4.1.2606.4.2.5.6.2 | ||
| Headline of output table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit3OutputEntry | |||
| cmcTcUnit3OutputEntry | 1.3.6.1.4.1.2606.4.2.5.6.2.1 | ||
| Entries of output table | |||
| OBJECT-TYPE | |||
| CmcTcUnit3OutputEntry | |||
| unit3OutputIndex | 1.3.6.1.4.1.2606.4.2.5.6.2.1.1 | ||
| Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfOutputs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit3OutputType | 1.3.6.1.4.1.2606.4.2.5.6.2.1.2 | ||
| Type of output which is connected to sensor unit 3 to output[unit3OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15) | ||
| unit3OutputText | 1.3.6.1.4.1.2606.4.2.5.6.2.1.3 | ||
| Descriptional text for each output (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit3OutputStatus | 1.3.6.1.4.1.2606.4.2.5.6.2.1.4 | ||
| Actual status of the output | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8) | ||
| unit3OutputValue | 1.3.6.1.4.1.2606.4.2.5.6.2.1.5 | ||
| Value for output | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit3OutputSet | 1.3.6.1.4.1.2606.4.2.5.6.2.1.6 | ||
| Command for output | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), lock(3), unlock(4), unlockDelay(5) | ||
| unit3OutputConfig | 1.3.6.1.4.1.2606.4.2.5.6.2.1.7 | ||
| Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control | |||
| OBJECT-TYPE | |||
| INTEGER | disRemote(1), enRemote(2) | ||
| unit3OutputDelay | 1.3.6.1.4.1.2606.4.2.5.6.2.1.8 | ||
| Unsigned Value for delay, after this time the output will fall into the previous state | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit3OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.5.6.2.1.9 | ||
| State for output if timeout (RS422) occurs | |||
| OBJECT-TYPE | |||
| INTEGER | stay(1), off(2), on(3) | ||
| cmcTcStatusUnit3Msg | 1.3.6.1.4.1.2606.4.2.5.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit3NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.5.7.1 | ||
| Number of alarms that can be created with sensor unit 3 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit3MsgTable | 1.3.6.1.4.1.2606.4.2.5.7.2 | ||
| Headline of message table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit3MsgEntry | |||
| cmcTcUnit3MsgEntry | 1.3.6.1.4.1.2606.4.2.5.7.2.1 | ||
| Entries of message table | |||
| OBJECT-TYPE | |||
| CmcTcUnit3MsgEntry | |||
| unit3MsgIndex | 1.3.6.1.4.1.2606.4.2.5.7.2.1.1 | ||
| Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfMsgs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit3MsgText | 1.3.6.1.4.1.2606.4.2.5.7.2.1.2 | ||
| Descriptional text for each message (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit3MsgStatus | 1.3.6.1.4.1.2606.4.2.5.7.2.1.3 | ||
| Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) | ||
| unit3MsgRelay | 1.3.6.1.4.1.2606.4.2.5.7.2.1.4 | ||
| Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgBeeper | 1.3.6.1.4.1.2606.4.2.5.7.2.1.5 | ||
| Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgTrap1 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.6 | ||
| Trap receiver 1 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgTrap2 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.7 | ||
| Trap receiver 2 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgTrap3 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.8 | ||
| Trap receiver 3 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgTrap4 | 1.3.6.1.4.1.2606.4.2.5.7.2.1.9 | ||
| Trap receiver 4 and Event Logging activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit3MsgQuit | 1.3.6.1.4.1.2606.4.2.5.7.2.1.10 | ||
| Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key | |||
| OBJECT-TYPE | |||
| INTEGER | auto(1), manual(2) | ||
| cmcTcStatusSensorUnit4 | 1.3.6.1.4.1.2606.4.2.6 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit4TypeOfDevice | 1.3.6.1.4.1.2606.4.2.6.1 | ||
| Type of sensor unit connected to port 4 | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6) | ||
| cmcTcUnit4Text | 1.3.6.1.4.1.2606.4.2.6.2 | ||
| Descriptional text for sensor unit connected to port 4 | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| cmcTcUnit4Serial | 1.3.6.1.4.1.2606.4.2.6.3 | ||
| Serialnumber of sensor unit connected to port 4 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit4Status | 1.3.6.1.4.1.2606.4.2.6.4 | ||
| General Status sensor unit connected to port 4 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low | |||
| OBJECT-TYPE | |||
| INTEGER | ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8) | ||
| cmcTcStatusUnit4Sensors | 1.3.6.1.4.1.2606.4.2.6.5 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit4NumberOfSensors | 1.3.6.1.4.1.2606.4.2.6.5.1 | ||
| Number of sensors connected to sensor unit 4 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit4SensorTable | 1.3.6.1.4.1.2606.4.2.6.5.2 | ||
| Headline of sensor table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit4SensorEntry | |||
| cmcTcUnit4SensorEntry | 1.3.6.1.4.1.2606.4.2.6.5.2.1 | ||
| Entries of sensor table | |||
| OBJECT-TYPE | |||
| CmcTcUnit4SensorEntry | |||
| unit4SensorIndex | 1.3.6.1.4.1.2606.4.2.6.5.2.1.1 | ||
| Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfSensors. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit4SensorType | 1.3.6.1.4.1.2606.4.2.6.5.2.1.2 | ||
| Type of sensor which is connected to sensor unit 4 to sensor[unit4SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26) | ||
| unit4SensorText | 1.3.6.1.4.1.2606.4.2.6.5.2.1.3 | ||
| Descriptional text for each sensor (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit4SensorStatus | 1.3.6.1.4.1.2606.4.2.6.5.2.1.4 | ||
| Actual status of the sensor | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9) | ||
| unit4SensorValue | 1.3.6.1.4.1.2606.4.2.6.5.2.1.5 | ||
| Value of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit4SensorSetHigh | 1.3.6.1.4.1.2606.4.2.6.5.2.1.6 | ||
| Value for high setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit4SensorSetLow | 1.3.6.1.4.1.2606.4.2.6.5.2.1.7 | ||
| Value for low setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit4SensorSetWarn | 1.3.6.1.4.1.2606.4.2.6.5.2.1.8 | ||
| Value for warning setpoint of sensor, also used as fan threshold | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcStatusUnit4Outputs | 1.3.6.1.4.1.2606.4.2.6.6 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit4NumberOfOutputs | 1.3.6.1.4.1.2606.4.2.6.6.1 | ||
| Number of outputs available on sensor unit 4 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit4OutputTable | 1.3.6.1.4.1.2606.4.2.6.6.2 | ||
| Headline of output table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit4OutputEntry | |||
| cmcTcUnit4OutputEntry | 1.3.6.1.4.1.2606.4.2.6.6.2.1 | ||
| Entries of output table | |||
| OBJECT-TYPE | |||
| CmcTcUnit4OutputEntry | |||
| unit4OutputIndex | 1.3.6.1.4.1.2606.4.2.6.6.2.1.1 | ||
| Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfOutputs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit4OutputType | 1.3.6.1.4.1.2606.4.2.6.6.2.1.2 | ||
| Type of output which is connected to sensor unit 4 to output[unit4OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15) | ||
| unit4OutputText | 1.3.6.1.4.1.2606.4.2.6.6.2.1.3 | ||
| Descriptional text for each output (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit4OutputStatus | 1.3.6.1.4.1.2606.4.2.6.6.2.1.4 | ||
| Actual status of the output | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8) | ||
| unit4OutputValue | 1.3.6.1.4.1.2606.4.2.6.6.2.1.5 | ||
| Value for output | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit4OutputSet | 1.3.6.1.4.1.2606.4.2.6.6.2.1.6 | ||
| Command for output | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), lock(3), unlock(4), unlockDelay(5) | ||
| unit4OutputConfig | 1.3.6.1.4.1.2606.4.2.6.6.2.1.7 | ||
| Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control | |||
| OBJECT-TYPE | |||
| INTEGER | disRemote(1), enRemote(2) | ||
| unit4OutputDelay | 1.3.6.1.4.1.2606.4.2.6.6.2.1.8 | ||
| Unsigned Value for delay, after this time the output will fall into the previous state | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| unit4OutputTimeoutAction | 1.3.6.1.4.1.2606.4.2.6.6.2.1.9 | ||
| State for output if timeout (RS422) occurs | |||
| OBJECT-TYPE | |||
| INTEGER | stay(1), off(2), on(3) | ||
| cmcTcStatusUnit4Msg | 1.3.6.1.4.1.2606.4.2.6.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcUnit4NumberOfMsgs | 1.3.6.1.4.1.2606.4.2.6.7.1 | ||
| Number of alarms that can be created with sensor unit 4 | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcUnit4MsgTable | 1.3.6.1.4.1.2606.4.2.6.7.2 | ||
| Headline of message table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcUnit4MsgEntry | |||
| cmcTcUnit4MsgEntry | 1.3.6.1.4.1.2606.4.2.6.7.2.1 | ||
| Entries of message table | |||
| OBJECT-TYPE | |||
| CmcTcUnit4MsgEntry | |||
| unit4MsgIndex | 1.3.6.1.4.1.2606.4.2.6.7.2.1.1 | ||
| Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfMsgs. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| unit4MsgText | 1.3.6.1.4.1.2606.4.2.6.7.2.1.2 | ||
| Descriptional text for each message (entry in the table) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| unit4MsgStatus | 1.3.6.1.4.1.2606.4.2.6.7.2.1.3 | ||
| Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) | ||
| unit4MsgRelay | 1.3.6.1.4.1.2606.4.2.6.7.2.1.4 | ||
| Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgBeeper | 1.3.6.1.4.1.2606.4.2.6.7.2.1.5 | ||
| Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgTrap1 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.6 | ||
| Trap receiver 1 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgTrap2 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.7 | ||
| Trap receiver 2 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgTrap3 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.8 | ||
| Trap receiver 3 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgTrap4 | 1.3.6.1.4.1.2606.4.2.6.7.2.1.9 | ||
| Trap receiver 4 and Event Logging activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| unit4MsgQuit | 1.3.6.1.4.1.2606.4.2.6.7.2.1.10 | ||
| Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key | |||
| OBJECT-TYPE | |||
| INTEGER | auto(1), manual(2) | ||
| cmcTcStatusExtUnit | 1.3.6.1.4.1.2606.4.2.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcValuesRelay | 1.3.6.1.4.1.2606.4.2.7.1 | ||
| Setup of Alarm relay for alarm ext. unit(s) 1: no switching of alarm relay 2: switching of alarm relay | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcValuesBeeper | 1.3.6.1.4.1.2606.4.2.7.2 | ||
| Setup of Alarm beeper for alarm ext. unit(s) 1: no audible alarm 2: audible alarm | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcValuesTrap1 | 1.3.6.1.4.1.2606.4.2.7.3 | ||
| Trap receiver 1 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcValuesTrap2 | 1.3.6.1.4.1.2606.4.2.7.4 | ||
| Trap receiver 2 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcValuesTrap3 | 1.3.6.1.4.1.2606.4.2.7.5 | ||
| Trap receiver 3 activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcValuesTrap4 | 1.3.6.1.4.1.2606.4.2.7.6 | ||
| Trap receiver 4 and Event Logging activated | |||
| OBJECT-TYPE | |||
| INTEGER | disable(1), enable(2) | ||
| cmcTcNumberOfValues | 1.3.6.1.4.1.2606.4.2.7.7 | ||
| Number of values availabel on extension units connected to the CMC | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcValuesTable | 1.3.6.1.4.1.2606.4.2.7.8 | ||
| Headline of values-table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcValuesEntry | |||
| cmcTcValuesEntry | 1.3.6.1.4.1.2606.4.2.7.8.1 | ||
| Entries of values-table | |||
| OBJECT-TYPE | |||
| CmcTcValuesEntry | |||
| valuesIndex | 1.3.6.1.4.1.2606.4.2.7.8.1.1 | ||
| Index for the list of value entries. Its value ranges between 1 and the value of cmcTcNumberOfValues. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| valuesText | 1.3.6.1.4.1.2606.4.2.7.8.1.2 | ||
| Descriptional text for each value (entry in the table) of the extension card | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| valuesStatus | 1.3.6.1.4.1.2606.4.2.7.8.1.3 | ||
| Actual status of the value of the extension card | |||
| OBJECT-TYPE | |||
| INTEGER | notAvail(1), lost(2), changed(3), ok(4), tooLow(5), tooHigh(6), error(7) | ||
| valuesValue | 1.3.6.1.4.1.2606.4.2.7.8.1.4 | ||
| Value of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| valuesSetHigh | 1.3.6.1.4.1.2606.4.2.7.8.1.5 | ||
| Value for high setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| valuesSetLow | 1.3.6.1.4.1.2606.4.2.7.8.1.6 | ||
| Value for low setpoint of sensor | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcSetup | 1.3.6.1.4.1.2606.4.3 | ||
| OBJECT IDENTIFIER | |||
| alarmSensorUnit3 | 1.3.6.1.4.1.2606.4.3 | ||
| Alarm of sensor unit 3 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| unit3MsgIndex | |||
| unit3MsgText | |||
| unit3MsgStatus | |||
| unit3SensorValue | |||
| cmcTcSetupGeneral | 1.3.6.1.4.1.2606.4.3.1 | ||
| OBJECT IDENTIFIER | |||
| cmcTcSetTempUnit | 1.3.6.1.4.1.2606.4.3.1.1 | ||
| Unit of all temperature values and setpoints, Celsius or Fahrenheit | |||
| OBJECT-TYPE | |||
| INTEGER | celsius(1), fahrenheit(2) | ||
| cmcTcSetBeeper | 1.3.6.1.4.1.2606.4.3.1.2 | ||
| Audible alarm in CMC-TC unit: (2): beeper is on (1): beeper is off (general) | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| cmcTcQuitRelay | 1.3.6.1.4.1.2606.4.3.1.3 | ||
| Enable or disable acknowledging currently active alarm relay (with 'C' on CMC-TC). | |||
| OBJECT-TYPE | |||
| INTEGER | disabled(1), enabled(2) | ||
| cmcTcLogicRelay | 1.3.6.1.4.1.2606.4.3.1.4 | ||
| Logic of alarm relay: (1) Relay will pick up in case of an alarm (2) Relay will release in case of an alarm (3) Relay off (general) | |||
| OBJECT-TYPE | |||
| INTEGER | closeAtAlarm(1), openAtAlarm(2), off(3) | ||
| cmcTcWebAccess | 1.3.6.1.4.1.2606.4.3.1.5 | ||
| Web access via HTTP: (1) view only (2) full Access, read and set (3) Web disabled (general) | |||
| OBJECT-TYPE | |||
| INTEGER | viewOnly(1), fullAccess(2), off(3) | ||
| cmcTcSetupDate | 1.3.6.1.4.1.2606.4.3.1.6 | ||
| actual Date in format DD.MM.YYYY | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| cmcTcSetupTime | 1.3.6.1.4.1.2606.4.3.1.7 | ||
| actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59) | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| cmcTcTimerTable1 | 1.3.6.1.4.1.2606.4.3.1.8 | ||
| OBJECT IDENTIFIER | |||
| cmcTcTimerNumber | 1.3.6.1.4.1.2606.4.3.1.8.1 | ||
| Number of value-table entries=number of outlets available on this unit | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcTimerTable | 1.3.6.1.4.1.2606.4.3.1.8.2 | ||
| Headline of status-table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcTimerEntry | |||
| cmcTcTimerEntry | 1.3.6.1.4.1.2606.4.3.1.8.2.1 | ||
| Entries of timer-table | |||
| OBJECT-TYPE | |||
| CmcTcTimerEntry | |||
| cmcTcTimerIndex | 1.3.6.1.4.1.2606.4.3.1.8.2.1.1 | ||
| Index for the list of timer entries. Its value ranges between 1 and the value of cmcTcTimerNumber. | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| cmcTcTimerStatus | 1.3.6.1.4.1.2606.4.3.1.8.2.1.2 | ||
| Actual status of the timer | |||
| OBJECT-TYPE | |||
| INTEGER | switchedOff(1), switchedOn(2), noTime(3) | ||
| cmcTcTimerDayOfWeek | 1.3.6.1.4.1.2606.4.3.1.8.2.1.3 | ||
| Selection of day of week for timer to switch | |||
| OBJECT-TYPE | |||
| INTEGER | sun(1), mon(2), tue(3), wed(4), thu(5), fri(6), sat(7), sat-sun(8), mon-fri(9), mon-sun(10) | ||
| cmcTcTimeOn | 1.3.6.1.4.1.2606.4.3.1.8.2.1.4 | ||
| Time to switch on current function, Format: HH:MM | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..5) | ||
| cmcTcTimeOff | 1.3.6.1.4.1.2606.4.3.1.8.2.1.5 | ||
| Time to switch off current function, Format: HH:MM | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..5) | ||
| cmcTcTimeControl | 1.3.6.1.4.1.2606.4.3.1.8.2.1.6 | ||
| Control via RTC | |||
| OBJECT-TYPE | |||
| INTEGER | disabled(1), enabled(2) | ||
| cmcTcTimerFunction | 1.3.6.1.4.1.2606.4.3.1.8.2.1.7 | ||
| Function which is controlled via timer 1: unlock via keypad 1 on unit 1 or remote input lock 1 is disabled 2: unlock via keypad 2 on unit 1 or remote input lock 2 is disabled 3 unlock via keypad 1 on unit 2 or remote input lock 1 is disabled 4: unlock via keypad 2 on unit 2 or remote input lock 2 is disabled 5: unlock via keypad 1 on unit 3 or remote input lock 1 is disabled 6: unlock via keypad 2 on unit 3 or remote input lock 2 is disabled 7: unlock via keypad 1 on unit 4 or remote input lock 1 is disabled 8: unlock via keypad 2 on unit 4 or remote input lock 2 is disabled 9: Lock of door 1 on unit 1 will be unlocked 10: Lock of door 2 on unit 1 will be unlocked 11: Lock of door 1 on unit 2 will be unlocked 12: Lock of door 2 on unit 2 will be unlocked 13: Lock of door 1 on unit 3 will be unlocked 14: Lock of door 2 on unit 3 will be unlocked 15: Lock of door 1 on unit 4 will be unlocked 16: Lock of door 2 on unit 4 will be unlocked 17-20: sending Traps to this Trap receiver will be disabled | |||
| OBJECT-TYPE | |||
| INTEGER | disKeypad1-1(1), disKeypad2-1(2), disKeypad1-2(3), disKeypad2-2(4), disKeypad1-3(5), disKeypad2-3(6), disKeypad1-4(7), disKeypad2-4(8), unlDoor1-1(9), unlDoor2-1(10), unlDoor1-2(11), unlDoor2-2(12), unlDoor1-3(13), unlDoor2-3(14), unlDoor1-4(15), unlDoor2-5(16), disTrapRec1(17), disTrapRec2(18), disTrapRec3(19), disTrapRec4(20) | ||
| cmcTcTrapControl | 1.3.6.1.4.1.2606.4.4 | ||
| OBJECT IDENTIFIER | |||
| alarmSensorUnit4 | 1.3.6.1.4.1.2606.4.4 | ||
| Alarm of sensor unit 4 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| unit4MsgIndex | |||
| unit4MsgText | |||
| unit4MsgStatus | |||
| unit4SensorValue | |||
| cmcTcTraps | 1.3.6.1.4.1.2606.4.4.7 | ||
| OBJECT IDENTIFIER | |||
| cmcTcTraptableNumber | 1.3.6.1.4.1.2606.4.4.7.1 | ||
| Number of trapTable entries. The number of trap-receiver | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| cmcTcTrapTableTable | 1.3.6.1.4.1.2606.4.4.7.2 | ||
| A list of trap-receiver entries | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| CmcTcTrapTableEntry | |||
| cmcTcTrapTableEntry | 1.3.6.1.4.1.2606.4.4.7.2.1 | ||
| Entries of trapTable | |||
| OBJECT-TYPE | |||
| CmcTcTrapTableEntry | |||
| trapIndex | 1.3.6.1.4.1.2606.4.4.7.2.1.1 | ||
| Index for the trap-receiver-table. Its value ranges between 1 and the value of traptableNumber | |||
| OBJECT-TYPE | |||
| INTEGER | 1..65535 | ||
| trapStatus | 1.3.6.1.4.1.2606.4.4.7.2.1.2 | ||
| Enable or disable trap receiver | |||
| OBJECT-TYPE | |||
| INTEGER | disabled(1), enabled(2) | ||
| trapIPaddress | 1.3.6.1.4.1.2606.4.4.7.2.1.3 | ||
| IP-address of trap-receiver | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..15) | ||
| cmcTcControl | 1.3.6.1.4.1.2606.4.5 | ||
| OBJECT IDENTIFIER | |||
| alarmUnit1 | 1.3.6.1.4.1.2606.4.5 | ||
| Alarm of unit 1 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| cmcTcUnit1Text | |||
| cmcTcUnit1Status | |||
| cmcTcQuitUnit | 1.3.6.1.4.1.2606.4.5.1 | ||
| Command to quit (acknowledge) alarms of CMC-TC unit. Setting to 'quit' (2) will have same result as pressing 'C' on Units. Variable is automatically set back to 'noQuit' (1). | |||
| OBJECT-TYPE | |||
| INTEGER | noQuit(1), quit(2) | ||
| alarmUnit2 | 1.3.6.1.4.1.2606.4.6 | ||
| Alarm of unit 2 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| cmcTcUnit2Text | |||
| cmcTcUnit2Status | |||
| alarmUnit3 | 1.3.6.1.4.1.2606.4.7 | ||
| Alarm of unit 3 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| cmcTcUnit3Text | |||
| cmcTcUnit3Status | |||
| alarmUnit4 | 1.3.6.1.4.1.2606.4.8 | ||
| Alarm of unit 4 | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| cmcTcUnit4Text | |||
| cmcTcUnit4Status | |||
| alarmValues | 1.3.6.1.4.1.2606.4.9 | ||
| Alarm of values measured by external card | |||
| TRAP-TYPE | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| valuesIndex | |||
| valuesText | |||
| valuesStatus | |||
| configChanged | 1.3.6.1.4.1.2606.4.10 | ||
| The configuration of the cmc has changed, this trap is send if new setup is saved. Configuration can be changed by Terminal, Telnet, Web or SNMP *** NOT IMPLEMENTED *** | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysContact | |||
| sysName | |||
| sysLocation | |||
| CmcTcUnit1SensorEntry | |||
| SEQUENCE | |||
| INTEGER as unit1SensorIndex | |||
| INTEGER as unit1SensorType | |||
| DisplayString as unit1SensorText | SIZE(0..20) | ||
| INTEGER as unit1SensorStatus | |||
| INTEGER as unit1SensorValue | |||
| INTEGER as unit1SensorSetHigh | |||
| INTEGER as unit1SensorSetLow | |||
| INTEGER as unit1SensorSetWarn | |||
| CmcTcUnit1OutputEntry | |||
| SEQUENCE | |||
| INTEGER as unit1OutputIndex | |||
| INTEGER as unit1OutputType | |||
| DisplayString as unit1OutputText | SIZE(0..20) | ||
| INTEGER as unit1OutputStatus | |||
| INTEGER as unit1OutputValue | |||
| INTEGER as unit1OutputSet | |||
| INTEGER as unit1OutputConfig | |||
| INTEGER as unit1OutputDelay | |||
| INTEGER as unit1OutputTimeoutAction | |||
| CmcTcUnit1MsgEntry | |||
| SEQUENCE | |||
| INTEGER as unit1MsgIndex | |||
| DisplayString as unit1MsgText | SIZE(0..20) | ||
| INTEGER as unit1MsgStatus | |||
| INTEGER as unit1MsgRelay | |||
| INTEGER as unit1MsgBeeper | |||
| INTEGER as unit1MsgTrap1 | |||
| INTEGER as unit1MsgTrap2 | |||
| INTEGER as unit1MsgTrap3 | |||
| INTEGER as unit1MsgTrap4 | |||
| INTEGER as unit1MsgQuit | |||
| CmcTcUnit2SensorEntry | |||
| SEQUENCE | |||
| INTEGER as unit2SensorIndex | |||
| INTEGER as unit2SensorType | |||
| DisplayString as unit2SensorText | SIZE(0..20) | ||
| INTEGER as unit2SensorStatus | |||
| INTEGER as unit2SensorValue | |||
| INTEGER as unit2SensorSetHigh | |||
| INTEGER as unit2SensorSetLow | |||
| INTEGER as unit2SensorSetWarn | |||
| CmcTcUnit2OutputEntry | |||
| SEQUENCE | |||
| INTEGER as unit2OutputIndex | |||
| INTEGER as unit2OutputType | |||
| DisplayString as unit2OutputText | SIZE(0..20) | ||
| INTEGER as unit2OutputStatus | |||
| INTEGER as unit2OutputValue | |||
| INTEGER as unit2OutputSet | |||
| INTEGER as unit2OutputConfig | |||
| INTEGER as unit2OutputDelay | |||
| INTEGER as unit2OutputTimeoutAction | |||
| CmcTcUnit2MsgEntry | |||
| SEQUENCE | |||
| INTEGER as unit2MsgIndex | |||
| DisplayString as unit2MsgText | SIZE(0..20) | ||
| INTEGER as unit2MsgStatus | |||
| INTEGER as unit2MsgRelay | |||
| INTEGER as unit2MsgBeeper | |||
| INTEGER as unit2MsgTrap1 | |||
| INTEGER as unit2MsgTrap2 | |||
| INTEGER as unit2MsgTrap3 | |||
| INTEGER as unit2MsgTrap4 | |||
| INTEGER as unit2MsgQuit | |||
| CmcTcUnit3SensorEntry | |||
| SEQUENCE | |||
| INTEGER as unit3SensorIndex | |||
| INTEGER as unit3SensorType | |||
| DisplayString as unit3SensorText | SIZE(0..20) | ||
| INTEGER as unit3SensorStatus | |||
| INTEGER as unit3SensorValue | |||
| INTEGER as unit3SensorSetHigh | |||
| INTEGER as unit3SensorSetLow | |||
| INTEGER as unit3SensorSetWarn | |||
| CmcTcUnit3OutputEntry | |||
| SEQUENCE | |||
| INTEGER as unit3OutputIndex | |||
| INTEGER as unit3OutputType | |||
| DisplayString as unit3OutputText | SIZE(0..20) | ||
| INTEGER as unit3OutputStatus | |||
| INTEGER as unit3OutputValue | |||
| INTEGER as unit3OutputSet | |||
| INTEGER as unit3OutputConfig | |||
| INTEGER as unit3OutputDelay | |||
| INTEGER as unit3OutputTimeoutAction | |||
| CmcTcUnit3MsgEntry | |||
| SEQUENCE | |||
| INTEGER as unit3MsgIndex | |||
| DisplayString as unit3MsgText | SIZE(0..20) | ||
| INTEGER as unit3MsgStatus | |||
| INTEGER as unit3MsgRelay | |||
| INTEGER as unit3MsgBeeper | |||
| INTEGER as unit3MsgTrap1 | |||
| INTEGER as unit3MsgTrap2 | |||
| INTEGER as unit3MsgTrap3 | |||
| INTEGER as unit3MsgTrap4 | |||
| INTEGER as unit3MsgQuit | |||
| CmcTcUnit4SensorEntry | |||
| SEQUENCE | |||
| INTEGER as unit4SensorIndex | |||
| INTEGER as unit4SensorType | |||
| DisplayString as unit4SensorText | SIZE(0..20) | ||
| INTEGER as unit4SensorStatus | |||
| INTEGER as unit4SensorValue | |||
| INTEGER as unit4SensorSetHigh | |||
| INTEGER as unit4SensorSetLow | |||
| INTEGER as unit4SensorSetWarn | |||
| CmcTcUnit4OutputEntry | |||
| SEQUENCE | |||
| INTEGER as unit4OutputIndex | |||
| INTEGER as unit4OutputType | |||
| DisplayString as unit4OutputText | SIZE(0..20) | ||
| INTEGER as unit4OutputStatus | |||
| INTEGER as unit4OutputValue | |||
| INTEGER as unit4OutputSet | |||
| INTEGER as unit4OutputConfig | |||
| INTEGER as unit4OutputDelay | |||
| INTEGER as unit4OutputTimeoutAction | |||
| CmcTcUnit4MsgEntry | |||
| SEQUENCE | |||
| INTEGER as unit4MsgIndex | |||
| DisplayString as unit4MsgText | SIZE(0..20) | ||
| INTEGER as unit4MsgStatus | |||
| INTEGER as unit4MsgRelay | |||
| INTEGER as unit4MsgBeeper | |||
| INTEGER as unit4MsgTrap1 | |||
| INTEGER as unit4MsgTrap2 | |||
| INTEGER as unit4MsgTrap3 | |||
| INTEGER as unit4MsgTrap4 | |||
| INTEGER as unit4MsgQuit | |||
| CmcTcValuesEntry | |||
| SEQUENCE | |||
| INTEGER as valuesIndex | |||
| DisplayString as valuesText | SIZE(0..20) | ||
| INTEGER as valuesStatus | |||
| INTEGER as valuesValue | |||
| INTEGER as valuesSetHigh | |||
| INTEGER as valuesSetLow | |||
| CmcTcTimerEntry | |||
| SEQUENCE | |||
| INTEGER as cmcTcTimerIndex | |||
| INTEGER as cmcTcTimerStatus | |||
| INTEGER as cmcTcTimerDayOfWeek | |||
| DisplayString as cmcTcTimeOn | SIZE(0..5) | ||
| DisplayString as cmcTcTimeOff | SIZE(0..5) | ||
| INTEGER as cmcTcTimeControl | |||
| INTEGER as cmcTcTimerFunction | |||
| CmcTcTrapTableEntry | |||
| SEQUENCE | |||
| INTEGER as trapIndex | |||
| INTEGER as trapStatus | |||
| DisplayString as trapIPaddress | |||