RITTAL-CMC-TC-MIB

File: RITTAL-CMC-TC-MIB.mib (113390 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises DisplayString sysName
sysDescr sysContact sysLocation
OBJECT-TYPE TRAP-TYPE

Defined Objects

rittal 1.3.6.1.4.1.2606
OBJECT IDENTIFIER    

cmcTc 1.3.6.1.4.1.2606.4
OBJECT IDENTIFIER    

cmcTcMibRev 1.3.6.1.4.1.2606.4.1
OBJECT IDENTIFIER    

alarmSensorUnit1 1.3.6.1.4.1.2606.4.1
Alarm of Sensor unit 1
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  unit1MsgIndex  
  unit1MsgText  
  unit1MsgStatus  
  unit1SensorValue  

cmcTcMibMajRev 1.3.6.1.4.1.2606.4.1.1
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level.
OBJECT-TYPE    
  INTEGER 1..65535  

cmcTcMibMinRev 1.3.6.1.4.1.2606.4.1.2
The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
OBJECT-TYPE    
  INTEGER 0..65535  

cmcTcMibCondition 1.3.6.1.4.1.2606.4.1.3
The overall condition (status) of the system represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC) (5) configuration of sensor units changed or unit detected (red/yellow/green LED on CMC)
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4), configChanged(5)  

cmcTcStatus 1.3.6.1.4.1.2606.4.2
OBJECT IDENTIFIER    

alarmSensorUnit2 1.3.6.1.4.1.2606.4.2
Alarm of sensor unit 2
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  unit2MsgIndex  
  unit2MsgText  
  unit2MsgStatus  
  unit2SensorValue  

cmcTcStatusDeviceCMC 1.3.6.1.4.1.2606.4.2.1
General Status of CMC-TC unit itself (1) failed (2) OK
OBJECT-TYPE    
  INTEGER failed(1), ok(2)  

cmcTcUnitsConnected 1.3.6.1.4.1.2606.4.2.2
Number of sensor units connected to the CMC, Port 1 to 4
OBJECT-TYPE    
  INTEGER  

cmcTcStatusSensorUnit1 1.3.6.1.4.1.2606.4.2.3
OBJECT IDENTIFIER    

cmcTcUnit1TypeOfDevice 1.3.6.1.4.1.2606.4.2.3.1
Type of sensor unit connected to port 1
OBJECT-TYPE    
  INTEGER notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6)  

cmcTcUnit1Text 1.3.6.1.4.1.2606.4.2.3.2
Descriptional text for sensor unit connected to port 1
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cmcTcUnit1Serial 1.3.6.1.4.1.2606.4.2.3.3
Serialnumber of sensor unit connected to port 1
OBJECT-TYPE    
  INTEGER  

cmcTcUnit1Status 1.3.6.1.4.1.2606.4.2.3.4
General Status sensor unit connected to port 1 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low
OBJECT-TYPE    
  INTEGER ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8)  

cmcTcStatusUnit1Sensors 1.3.6.1.4.1.2606.4.2.3.5
OBJECT IDENTIFIER    

cmcTcUnit1NumberOfSensors 1.3.6.1.4.1.2606.4.2.3.5.1
Number of sensors connected to sensor unit 1
OBJECT-TYPE    
  INTEGER  

cmcTcUnit1SensorTable 1.3.6.1.4.1.2606.4.2.3.5.2
Headline of sensor table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit1SensorEntry

cmcTcUnit1SensorEntry 1.3.6.1.4.1.2606.4.2.3.5.2.1
Entries of sensor table
OBJECT-TYPE    
  CmcTcUnit1SensorEntry  

unit1SensorIndex 1.3.6.1.4.1.2606.4.2.3.5.2.1.1
Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfSensors.
OBJECT-TYPE    
  INTEGER 1..65535  

unit1SensorType 1.3.6.1.4.1.2606.4.2.3.5.2.1.2
Type of sensor which is connected to sensor unit 1 to sensor[unit1SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage (OK, NOK) 18: voltage value 19: fan status, from CMC-TC-FAS-Unit 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26)  

unit1SensorText 1.3.6.1.4.1.2606.4.2.3.5.2.1.3
Descriptional text for each sensor (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit1SensorStatus 1.3.6.1.4.1.2606.4.2.3.5.2.1.4
Actual status of the sensor
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9)  

unit1SensorValue 1.3.6.1.4.1.2606.4.2.3.5.2.1.5
Value of sensor
OBJECT-TYPE    
  INTEGER  

unit1SensorSetHigh 1.3.6.1.4.1.2606.4.2.3.5.2.1.6
Value for high setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit1SensorSetLow 1.3.6.1.4.1.2606.4.2.3.5.2.1.7
Value for low setpoint of sensor, also used as alarm delay
OBJECT-TYPE    
  INTEGER  

unit1SensorSetWarn 1.3.6.1.4.1.2606.4.2.3.5.2.1.8
Value for warning setpoint of sensor, also used as fan threshold
OBJECT-TYPE    
  INTEGER  

cmcTcStatusUnit1Outputs 1.3.6.1.4.1.2606.4.2.3.6
OBJECT IDENTIFIER    

cmcTcUnit1NumberOfOutputs 1.3.6.1.4.1.2606.4.2.3.6.1
Number of outputs available on sensor unit 1
OBJECT-TYPE    
  INTEGER  

cmcTcUnit1OutputTable 1.3.6.1.4.1.2606.4.2.3.6.2
Headline of output table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit1OutputEntry

cmcTcUnit1OutputEntry 1.3.6.1.4.1.2606.4.2.3.6.2.1
Entries of output table
OBJECT-TYPE    
  CmcTcUnit1OutputEntry  

unit1OutputIndex 1.3.6.1.4.1.2606.4.2.3.6.2.1.1
Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfOutputs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit1OutputType 1.3.6.1.4.1.2606.4.2.3.6.2.1.2
Type of output which is connected to sensor unit 1 to output[unit1OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT)
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15)  

unit1OutputText 1.3.6.1.4.1.2606.4.2.3.6.2.1.3
Descriptional text for each output (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit1OutputStatus 1.3.6.1.4.1.2606.4.2.3.6.2.1.4
Actual status of the output
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8)  

unit1OutputValue 1.3.6.1.4.1.2606.4.2.3.6.2.1.5
Value for output
OBJECT-TYPE    
  INTEGER  

unit1OutputSet 1.3.6.1.4.1.2606.4.2.3.6.2.1.6
Command for output
OBJECT-TYPE    
  INTEGER off(1), on(2), lock(3), unlock(4), unlockDelay(5)  

unit1OutputConfig 1.3.6.1.4.1.2606.4.2.3.6.2.1.7
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control
OBJECT-TYPE    
  INTEGER disRemote(1), enRemote(2)  

unit1OutputDelay 1.3.6.1.4.1.2606.4.2.3.6.2.1.8
Unsigned Value for delay, after this time the output will fall into the previous state
OBJECT-TYPE    
  INTEGER  

unit1OutputTimeoutAction 1.3.6.1.4.1.2606.4.2.3.6.2.1.9
State for output if timeout (RS422) occurs
OBJECT-TYPE    
  INTEGER stay(1), off(2), on(3)  

cmcTcStatusUnit1Msg 1.3.6.1.4.1.2606.4.2.3.7
OBJECT IDENTIFIER    

cmcTcUnit1NumberOfMsgs 1.3.6.1.4.1.2606.4.2.3.7.1
Number of messages that can be created with sensor unit 1
OBJECT-TYPE    
  INTEGER  

cmcTcUnit1MsgTable 1.3.6.1.4.1.2606.4.2.3.7.2
Headline of message table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit1MsgEntry

cmcTcUnit1MsgEntry 1.3.6.1.4.1.2606.4.2.3.7.2.1
Entries of message table
OBJECT-TYPE    
  CmcTcUnit1MsgEntry  

unit1MsgIndex 1.3.6.1.4.1.2606.4.2.3.7.2.1.1
Index for the list of message entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfMsgs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit1MsgText 1.3.6.1.4.1.2606.4.2.3.7.2.1.2
Descriptional text for each message (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit1MsgStatus 1.3.6.1.4.1.2606.4.2.3.7.2.1.3
Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber
OBJECT-TYPE    
  INTEGER notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19)  

unit1MsgRelay 1.3.6.1.4.1.2606.4.2.3.7.2.1.4
Setup of Alarm relay for this message/alarm 1: no switching of alarm relay 2: switching of alarm relay
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgBeeper 1.3.6.1.4.1.2606.4.2.3.7.2.1.5
Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgTrap1 1.3.6.1.4.1.2606.4.2.3.7.2.1.6
Trap receiver 1 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgTrap2 1.3.6.1.4.1.2606.4.2.3.7.2.1.7
Trap receiver 2 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgTrap3 1.3.6.1.4.1.2606.4.2.3.7.2.1.8
Trap receiver 3 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgTrap4 1.3.6.1.4.1.2606.4.2.3.7.2.1.9
Trap receiver 4 and Event Logging activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit1MsgQuit 1.3.6.1.4.1.2606.4.2.3.7.2.1.10
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

cmcTcStatusSensorUnit2 1.3.6.1.4.1.2606.4.2.4
OBJECT IDENTIFIER    

cmcTcUnit2TypeOfDevice 1.3.6.1.4.1.2606.4.2.4.1
Type of sensor unit connected to port 2
OBJECT-TYPE    
  INTEGER notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6)  

cmcTcUnit2Text 1.3.6.1.4.1.2606.4.2.4.2
Descriptional text for sensor unit connected to port 2
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cmcTcUnit2Serial 1.3.6.1.4.1.2606.4.2.4.3
Serialnumber of sensor unit connected to port 2
OBJECT-TYPE    
  INTEGER  

cmcTcUnit2Status 1.3.6.1.4.1.2606.4.2.4.4
General Status sensor unit connected to port 2 (1) OK (2) error (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required (6) sensor unit detected, needs to be confirmed (8) supply voltage is too low
OBJECT-TYPE    
  INTEGER ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8)  

cmcTcStatusUnit2Sensors 1.3.6.1.4.1.2606.4.2.4.5
OBJECT IDENTIFIER    

cmcTcUnit2NumberOfSensors 1.3.6.1.4.1.2606.4.2.4.5.1
Number of sensors connected to sensor unit 2
OBJECT-TYPE    
  INTEGER  

cmcTcUnit2SensorTable 1.3.6.1.4.1.2606.4.2.4.5.2
Headline of sensor table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit2SensorEntry

cmcTcUnit2SensorEntry 1.3.6.1.4.1.2606.4.2.4.5.2.1
Entries of sensor table
OBJECT-TYPE    
  CmcTcUnit2SensorEntry  

unit2SensorIndex 1.3.6.1.4.1.2606.4.2.4.5.2.1.1
Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfSensors.
OBJECT-TYPE    
  INTEGER 1..65535  

unit2SensorType 1.3.6.1.4.1.2606.4.2.4.5.2.1.2
Type of sensor which is connected to sensor unit 2 to sensor[unit2SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26)  

unit2SensorText 1.3.6.1.4.1.2606.4.2.4.5.2.1.3
Descriptional text for each sensor (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit2SensorStatus 1.3.6.1.4.1.2606.4.2.4.5.2.1.4
Actual status of the sensor
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9)  

unit2SensorValue 1.3.6.1.4.1.2606.4.2.4.5.2.1.5
Value of sensor
OBJECT-TYPE    
  INTEGER  

unit2SensorSetHigh 1.3.6.1.4.1.2606.4.2.4.5.2.1.6
Value for high setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit2SensorSetLow 1.3.6.1.4.1.2606.4.2.4.5.2.1.7
Value for low setpoint of sensor, also used as alarm delay
OBJECT-TYPE    
  INTEGER  

unit2SensorSetWarn 1.3.6.1.4.1.2606.4.2.4.5.2.1.8
Value for warning setpoint of sensor, also used as fan threshold
OBJECT-TYPE    
  INTEGER  

cmcTcStatusUnit2Outputs 1.3.6.1.4.1.2606.4.2.4.6
OBJECT IDENTIFIER    

cmcTcUnit2NumberOfOutputs 1.3.6.1.4.1.2606.4.2.4.6.1
Number of outputs available on sensor unit 2
OBJECT-TYPE    
  INTEGER  

cmcTcUnit2OutputTable 1.3.6.1.4.1.2606.4.2.4.6.2
Headline of output table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit2OutputEntry

cmcTcUnit2OutputEntry 1.3.6.1.4.1.2606.4.2.4.6.2.1
Entries of output table
OBJECT-TYPE    
  CmcTcUnit2OutputEntry  

unit2OutputIndex 1.3.6.1.4.1.2606.4.2.4.6.2.1.1
Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfOutputs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit2OutputType 1.3.6.1.4.1.2606.4.2.4.6.2.1.2
Type of output which is connected to sensor unit 2 to output[unit2OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT)
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15)  

unit2OutputText 1.3.6.1.4.1.2606.4.2.4.6.2.1.3
Descriptional text for each output (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit2OutputStatus 1.3.6.1.4.1.2606.4.2.4.6.2.1.4
Actual status of the output
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8)  

unit2OutputValue 1.3.6.1.4.1.2606.4.2.4.6.2.1.5
Signed value for output
OBJECT-TYPE    
  INTEGER  

unit2OutputSet 1.3.6.1.4.1.2606.4.2.4.6.2.1.6
Command for output
OBJECT-TYPE    
  INTEGER off(1), on(2), lock(3), unlock(4), unlockDelay(5)  

unit2OutputConfig 1.3.6.1.4.1.2606.4.2.4.6.2.1.7
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control
OBJECT-TYPE    
  INTEGER disRemote(1), enRemote(2)  

unit2OutputDelay 1.3.6.1.4.1.2606.4.2.4.6.2.1.8
Unsigned Value for delay, after this time the output will fall into the previous state
OBJECT-TYPE    
  INTEGER  

unit2OutputTimeoutAction 1.3.6.1.4.1.2606.4.2.4.6.2.1.9
State for output if timeout (RS422) occurs
OBJECT-TYPE    
  INTEGER stay(1), off(2), on(3)  

cmcTcStatusUnit2Msg 1.3.6.1.4.1.2606.4.2.4.7
OBJECT IDENTIFIER    

cmcTcUnit2NumberOfMsgs 1.3.6.1.4.1.2606.4.2.4.7.1
Number of alarms that can be created with sensor unit 2
OBJECT-TYPE    
  INTEGER  

cmcTcUnit2MsgTable 1.3.6.1.4.1.2606.4.2.4.7.2
Headline of message table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit2MsgEntry

cmcTcUnit2MsgEntry 1.3.6.1.4.1.2606.4.2.4.7.2.1
Entries of message table
OBJECT-TYPE    
  CmcTcUnit2MsgEntry  

unit2MsgIndex 1.3.6.1.4.1.2606.4.2.4.7.2.1.1
Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfMsgs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit2MsgText 1.3.6.1.4.1.2606.4.2.4.7.2.1.2
Descriptional text for each message (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit2MsgStatus 1.3.6.1.4.1.2606.4.2.4.7.2.1.3
Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber
OBJECT-TYPE    
  INTEGER notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19)  

unit2MsgRelay 1.3.6.1.4.1.2606.4.2.4.7.2.1.4
Setup of Alarm relay for this alarm 2: no switching of alarm relay 1: switching of alarm relay
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgBeeper 1.3.6.1.4.1.2606.4.2.4.7.2.1.5
Setup of Alarm beeper for this alarm 2: no audible alarm 1: audible alarm
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgTrap1 1.3.6.1.4.1.2606.4.2.4.7.2.1.6
Trap receiver 1 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgTrap2 1.3.6.1.4.1.2606.4.2.4.7.2.1.7
Trap receiver 2 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgTrap3 1.3.6.1.4.1.2606.4.2.4.7.2.1.8
Trap receiver 3 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgTrap4 1.3.6.1.4.1.2606.4.2.4.7.2.1.9
Trap receiver 4 and Event Logging activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit2MsgQuit 1.3.6.1.4.1.2606.4.2.4.7.2.1.10
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

cmcTcStatusSensorUnit3 1.3.6.1.4.1.2606.4.2.5
OBJECT IDENTIFIER    

cmcTcUnit3TypeOfDevice 1.3.6.1.4.1.2606.4.2.5.1
Type of sensor unit connected to port 3
OBJECT-TYPE    
  INTEGER notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6)  

cmcTcUnit3Text 1.3.6.1.4.1.2606.4.2.5.2
Descriptional text for sensor unit connected to port 3
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cmcTcUnit3Serial 1.3.6.1.4.1.2606.4.2.5.3
Serialnumber of sensor unit connected to port 3
OBJECT-TYPE    
  INTEGER  

cmcTcUnit3Status 1.3.6.1.4.1.2606.4.2.5.4
General Status sensor unit connected to port 3 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low
OBJECT-TYPE    
  INTEGER ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8)  

cmcTcStatusUnit3Sensors 1.3.6.1.4.1.2606.4.2.5.5
OBJECT IDENTIFIER    

cmcTcUnit3NumberOfSensors 1.3.6.1.4.1.2606.4.2.5.5.1
Number of sensors connected to sensor unit 3
OBJECT-TYPE    
  INTEGER  

cmcTcUnit3SensorTable 1.3.6.1.4.1.2606.4.2.5.5.2
Headline of sensor table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit3SensorEntry

cmcTcUnit3SensorEntry 1.3.6.1.4.1.2606.4.2.5.5.2.1
Entries of sensor table
OBJECT-TYPE    
  CmcTcUnit3SensorEntry  

unit3SensorIndex 1.3.6.1.4.1.2606.4.2.5.5.2.1.1
Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfSensors.
OBJECT-TYPE    
  INTEGER 1..65535  

unit3SensorType 1.3.6.1.4.1.2606.4.2.5.5.2.1.2
Type of sensor which is connected to sensor unit 3 to sensor[unit3SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26)  

unit3SensorText 1.3.6.1.4.1.2606.4.2.5.5.2.1.3
Descriptional text for each sensor (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit3SensorStatus 1.3.6.1.4.1.2606.4.2.5.5.2.1.4
Actual status of the sensor
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9)  

unit3SensorValue 1.3.6.1.4.1.2606.4.2.5.5.2.1.5
Value of sensor
OBJECT-TYPE    
  INTEGER  

unit3SensorSetHigh 1.3.6.1.4.1.2606.4.2.5.5.2.1.6
Value for high setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit3SensorSetLow 1.3.6.1.4.1.2606.4.2.5.5.2.1.7
Value for low setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit3SensorSetWarn 1.3.6.1.4.1.2606.4.2.5.5.2.1.8
Value for warning setpoint of sensor, also used as fan threshold
OBJECT-TYPE    
  INTEGER  

cmcTcStatusUnit3Outputs 1.3.6.1.4.1.2606.4.2.5.6
OBJECT IDENTIFIER    

cmcTcUnit3NumberOfOutputs 1.3.6.1.4.1.2606.4.2.5.6.1
Number of outputs available on sensor unit 3
OBJECT-TYPE    
  INTEGER  

cmcTcUnit3OutputTable 1.3.6.1.4.1.2606.4.2.5.6.2
Headline of output table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit3OutputEntry

cmcTcUnit3OutputEntry 1.3.6.1.4.1.2606.4.2.5.6.2.1
Entries of output table
OBJECT-TYPE    
  CmcTcUnit3OutputEntry  

unit3OutputIndex 1.3.6.1.4.1.2606.4.2.5.6.2.1.1
Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfOutputs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit3OutputType 1.3.6.1.4.1.2606.4.2.5.6.2.1.2
Type of output which is connected to sensor unit 3 to output[unit3OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT)
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15)  

unit3OutputText 1.3.6.1.4.1.2606.4.2.5.6.2.1.3
Descriptional text for each output (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit3OutputStatus 1.3.6.1.4.1.2606.4.2.5.6.2.1.4
Actual status of the output
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8)  

unit3OutputValue 1.3.6.1.4.1.2606.4.2.5.6.2.1.5
Value for output
OBJECT-TYPE    
  INTEGER  

unit3OutputSet 1.3.6.1.4.1.2606.4.2.5.6.2.1.6
Command for output
OBJECT-TYPE    
  INTEGER off(1), on(2), lock(3), unlock(4), unlockDelay(5)  

unit3OutputConfig 1.3.6.1.4.1.2606.4.2.5.6.2.1.7
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control
OBJECT-TYPE    
  INTEGER disRemote(1), enRemote(2)  

unit3OutputDelay 1.3.6.1.4.1.2606.4.2.5.6.2.1.8
Unsigned Value for delay, after this time the output will fall into the previous state
OBJECT-TYPE    
  INTEGER  

unit3OutputTimeoutAction 1.3.6.1.4.1.2606.4.2.5.6.2.1.9
State for output if timeout (RS422) occurs
OBJECT-TYPE    
  INTEGER stay(1), off(2), on(3)  

cmcTcStatusUnit3Msg 1.3.6.1.4.1.2606.4.2.5.7
OBJECT IDENTIFIER    

cmcTcUnit3NumberOfMsgs 1.3.6.1.4.1.2606.4.2.5.7.1
Number of alarms that can be created with sensor unit 3
OBJECT-TYPE    
  INTEGER  

cmcTcUnit3MsgTable 1.3.6.1.4.1.2606.4.2.5.7.2
Headline of message table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit3MsgEntry

cmcTcUnit3MsgEntry 1.3.6.1.4.1.2606.4.2.5.7.2.1
Entries of message table
OBJECT-TYPE    
  CmcTcUnit3MsgEntry  

unit3MsgIndex 1.3.6.1.4.1.2606.4.2.5.7.2.1.1
Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfMsgs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit3MsgText 1.3.6.1.4.1.2606.4.2.5.7.2.1.2
Descriptional text for each message (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit3MsgStatus 1.3.6.1.4.1.2606.4.2.5.7.2.1.3
Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber
OBJECT-TYPE    
  INTEGER notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19)  

unit3MsgRelay 1.3.6.1.4.1.2606.4.2.5.7.2.1.4
Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgBeeper 1.3.6.1.4.1.2606.4.2.5.7.2.1.5
Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgTrap1 1.3.6.1.4.1.2606.4.2.5.7.2.1.6
Trap receiver 1 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgTrap2 1.3.6.1.4.1.2606.4.2.5.7.2.1.7
Trap receiver 2 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgTrap3 1.3.6.1.4.1.2606.4.2.5.7.2.1.8
Trap receiver 3 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgTrap4 1.3.6.1.4.1.2606.4.2.5.7.2.1.9
Trap receiver 4 and Event Logging activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit3MsgQuit 1.3.6.1.4.1.2606.4.2.5.7.2.1.10
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

cmcTcStatusSensorUnit4 1.3.6.1.4.1.2606.4.2.6
OBJECT IDENTIFIER    

cmcTcUnit4TypeOfDevice 1.3.6.1.4.1.2606.4.2.6.1
Type of sensor unit connected to port 4
OBJECT-TYPE    
  INTEGER notAvail(1), unitIO(2), unitAccess(3), unitClimate(4), unitFCS(5), unitRTT(6)  

cmcTcUnit4Text 1.3.6.1.4.1.2606.4.2.6.2
Descriptional text for sensor unit connected to port 4
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cmcTcUnit4Serial 1.3.6.1.4.1.2606.4.2.6.3
Serialnumber of sensor unit connected to port 4
OBJECT-TYPE    
  INTEGER  

cmcTcUnit4Status 1.3.6.1.4.1.2606.4.2.6.4
General Status sensor unit connected to port 4 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low
OBJECT-TYPE    
  INTEGER ok(1), error(2), changed(3), quit(4), timeout(5), detected(6), notAvail(7), lowPower(8)  

cmcTcStatusUnit4Sensors 1.3.6.1.4.1.2606.4.2.6.5
OBJECT IDENTIFIER    

cmcTcUnit4NumberOfSensors 1.3.6.1.4.1.2606.4.2.6.5.1
Number of sensors connected to sensor unit 4
OBJECT-TYPE    
  INTEGER  

cmcTcUnit4SensorTable 1.3.6.1.4.1.2606.4.2.6.5.2
Headline of sensor table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit4SensorEntry

cmcTcUnit4SensorEntry 1.3.6.1.4.1.2606.4.2.6.5.2.1
Entries of sensor table
OBJECT-TYPE    
  CmcTcUnit4SensorEntry  

unit4SensorIndex 1.3.6.1.4.1.2606.4.2.6.5.2.1.1
Index for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfSensors.
OBJECT-TYPE    
  INTEGER 1..65535  

unit4SensorType 1.3.6.1.4.1.2606.4.2.6.5.2.1.2
Type of sensor which is connected to sensor unit 4 to sensor[unit4SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), access(4), vibration(5), motion(6), smoke(7), airFlow(8), type6(9), temperature(10), current4to20(11), humidity(12), userNO(13), userNC(14), lock(15), unlock(16), voltOK(17), voltage(18), fanOK(19), readerKeypad(20), dutyPWM(21), fanStatus(22), leakage(23), warningRTT(24), alarmRTT(25), filterRTT(26)  

unit4SensorText 1.3.6.1.4.1.2606.4.2.6.5.2.1.3
Descriptional text for each sensor (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit4SensorStatus 1.3.6.1.4.1.2606.4.2.6.5.2.1.4
Actual status of the sensor
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), warning(7), tooLow(8), tooHigh(9)  

unit4SensorValue 1.3.6.1.4.1.2606.4.2.6.5.2.1.5
Value of sensor
OBJECT-TYPE    
  INTEGER  

unit4SensorSetHigh 1.3.6.1.4.1.2606.4.2.6.5.2.1.6
Value for high setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit4SensorSetLow 1.3.6.1.4.1.2606.4.2.6.5.2.1.7
Value for low setpoint of sensor
OBJECT-TYPE    
  INTEGER  

unit4SensorSetWarn 1.3.6.1.4.1.2606.4.2.6.5.2.1.8
Value for warning setpoint of sensor, also used as fan threshold
OBJECT-TYPE    
  INTEGER  

cmcTcStatusUnit4Outputs 1.3.6.1.4.1.2606.4.2.6.6
OBJECT IDENTIFIER    

cmcTcUnit4NumberOfOutputs 1.3.6.1.4.1.2606.4.2.6.6.1
Number of outputs available on sensor unit 4
OBJECT-TYPE    
  INTEGER  

cmcTcUnit4OutputTable 1.3.6.1.4.1.2606.4.2.6.6.2
Headline of output table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit4OutputEntry

cmcTcUnit4OutputEntry 1.3.6.1.4.1.2606.4.2.6.6.2.1
Entries of output table
OBJECT-TYPE    
  CmcTcUnit4OutputEntry  

unit4OutputIndex 1.3.6.1.4.1.2606.4.2.6.6.2.1.1
Index for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfOutputs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit4OutputType 1.3.6.1.4.1.2606.4.2.6.6.2.1.2
Type of output which is connected to sensor unit 4 to output[unit4OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT)
OBJECT-TYPE    
  INTEGER notAvail(1), failure(2), overflow(3), doorLock(4), univLock1(5), univLock2(6), fan(7), fanSpeedContr(8), universalOut(9), roomLock(10), powerOut(11), doorLockMaster(12), doorLockFRi(13), setpoint(14), setpointTimax(15)  

unit4OutputText 1.3.6.1.4.1.2606.4.2.6.6.2.1.3
Descriptional text for each output (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit4OutputStatus 1.3.6.1.4.1.2606.4.2.6.6.2.1.4
Actual status of the output
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), off(5), on(6), setOff(7), setOn(8)  

unit4OutputValue 1.3.6.1.4.1.2606.4.2.6.6.2.1.5
Value for output
OBJECT-TYPE    
  INTEGER  

unit4OutputSet 1.3.6.1.4.1.2606.4.2.6.6.2.1.6
Command for output
OBJECT-TYPE    
  INTEGER off(1), on(2), lock(3), unlock(4), unlockDelay(5)  

unit4OutputConfig 1.3.6.1.4.1.2606.4.2.6.6.2.1.7
Configuration for output 1: disable remote control (e.g. keypad) 2: enable remote control
OBJECT-TYPE    
  INTEGER disRemote(1), enRemote(2)  

unit4OutputDelay 1.3.6.1.4.1.2606.4.2.6.6.2.1.8
Unsigned Value for delay, after this time the output will fall into the previous state
OBJECT-TYPE    
  INTEGER  

unit4OutputTimeoutAction 1.3.6.1.4.1.2606.4.2.6.6.2.1.9
State for output if timeout (RS422) occurs
OBJECT-TYPE    
  INTEGER stay(1), off(2), on(3)  

cmcTcStatusUnit4Msg 1.3.6.1.4.1.2606.4.2.6.7
OBJECT IDENTIFIER    

cmcTcUnit4NumberOfMsgs 1.3.6.1.4.1.2606.4.2.6.7.1
Number of alarms that can be created with sensor unit 4
OBJECT-TYPE    
  INTEGER  

cmcTcUnit4MsgTable 1.3.6.1.4.1.2606.4.2.6.7.2
Headline of message table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcUnit4MsgEntry

cmcTcUnit4MsgEntry 1.3.6.1.4.1.2606.4.2.6.7.2.1
Entries of message table
OBJECT-TYPE    
  CmcTcUnit4MsgEntry  

unit4MsgIndex 1.3.6.1.4.1.2606.4.2.6.7.2.1.1
Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfMsgs.
OBJECT-TYPE    
  INTEGER 1..65535  

unit4MsgText 1.3.6.1.4.1.2606.4.2.6.7.2.1.2
Descriptional text for each message (entry in the table)
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

unit4MsgStatus 1.3.6.1.4.1.2606.4.2.6.7.2.1.3
Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber
OBJECT-TYPE    
  INTEGER notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19)  

unit4MsgRelay 1.3.6.1.4.1.2606.4.2.6.7.2.1.4
Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgBeeper 1.3.6.1.4.1.2606.4.2.6.7.2.1.5
Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgTrap1 1.3.6.1.4.1.2606.4.2.6.7.2.1.6
Trap receiver 1 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgTrap2 1.3.6.1.4.1.2606.4.2.6.7.2.1.7
Trap receiver 2 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgTrap3 1.3.6.1.4.1.2606.4.2.6.7.2.1.8
Trap receiver 3 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgTrap4 1.3.6.1.4.1.2606.4.2.6.7.2.1.9
Trap receiver 4 and Event Logging activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

unit4MsgQuit 1.3.6.1.4.1.2606.4.2.6.7.2.1.10
Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

cmcTcStatusExtUnit 1.3.6.1.4.1.2606.4.2.7
OBJECT IDENTIFIER    

cmcTcValuesRelay 1.3.6.1.4.1.2606.4.2.7.1
Setup of Alarm relay for alarm ext. unit(s) 1: no switching of alarm relay 2: switching of alarm relay
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcValuesBeeper 1.3.6.1.4.1.2606.4.2.7.2
Setup of Alarm beeper for alarm ext. unit(s) 1: no audible alarm 2: audible alarm
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcValuesTrap1 1.3.6.1.4.1.2606.4.2.7.3
Trap receiver 1 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcValuesTrap2 1.3.6.1.4.1.2606.4.2.7.4
Trap receiver 2 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcValuesTrap3 1.3.6.1.4.1.2606.4.2.7.5
Trap receiver 3 activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcValuesTrap4 1.3.6.1.4.1.2606.4.2.7.6
Trap receiver 4 and Event Logging activated
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cmcTcNumberOfValues 1.3.6.1.4.1.2606.4.2.7.7
Number of values availabel on extension units connected to the CMC
OBJECT-TYPE    
  INTEGER  

cmcTcValuesTable 1.3.6.1.4.1.2606.4.2.7.8
Headline of values-table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcValuesEntry

cmcTcValuesEntry 1.3.6.1.4.1.2606.4.2.7.8.1
Entries of values-table
OBJECT-TYPE    
  CmcTcValuesEntry  

valuesIndex 1.3.6.1.4.1.2606.4.2.7.8.1.1
Index for the list of value entries. Its value ranges between 1 and the value of cmcTcNumberOfValues.
OBJECT-TYPE    
  INTEGER 1..65535  

valuesText 1.3.6.1.4.1.2606.4.2.7.8.1.2
Descriptional text for each value (entry in the table) of the extension card
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

valuesStatus 1.3.6.1.4.1.2606.4.2.7.8.1.3
Actual status of the value of the extension card
OBJECT-TYPE    
  INTEGER notAvail(1), lost(2), changed(3), ok(4), tooLow(5), tooHigh(6), error(7)  

valuesValue 1.3.6.1.4.1.2606.4.2.7.8.1.4
Value of sensor
OBJECT-TYPE    
  INTEGER  

valuesSetHigh 1.3.6.1.4.1.2606.4.2.7.8.1.5
Value for high setpoint of sensor
OBJECT-TYPE    
  INTEGER  

valuesSetLow 1.3.6.1.4.1.2606.4.2.7.8.1.6
Value for low setpoint of sensor
OBJECT-TYPE    
  INTEGER  

cmcTcSetup 1.3.6.1.4.1.2606.4.3
OBJECT IDENTIFIER    

alarmSensorUnit3 1.3.6.1.4.1.2606.4.3
Alarm of sensor unit 3
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  unit3MsgIndex  
  unit3MsgText  
  unit3MsgStatus  
  unit3SensorValue  

cmcTcSetupGeneral 1.3.6.1.4.1.2606.4.3.1
OBJECT IDENTIFIER    

cmcTcSetTempUnit 1.3.6.1.4.1.2606.4.3.1.1
Unit of all temperature values and setpoints, Celsius or Fahrenheit
OBJECT-TYPE    
  INTEGER celsius(1), fahrenheit(2)  

cmcTcSetBeeper 1.3.6.1.4.1.2606.4.3.1.2
Audible alarm in CMC-TC unit: (2): beeper is on (1): beeper is off (general)
OBJECT-TYPE    
  INTEGER off(1), on(2)  

cmcTcQuitRelay 1.3.6.1.4.1.2606.4.3.1.3
Enable or disable acknowledging currently active alarm relay (with 'C' on CMC-TC).
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cmcTcLogicRelay 1.3.6.1.4.1.2606.4.3.1.4
Logic of alarm relay: (1) Relay will pick up in case of an alarm (2) Relay will release in case of an alarm (3) Relay off (general)
OBJECT-TYPE    
  INTEGER closeAtAlarm(1), openAtAlarm(2), off(3)  

cmcTcWebAccess 1.3.6.1.4.1.2606.4.3.1.5
Web access via HTTP: (1) view only (2) full Access, read and set (3) Web disabled (general)
OBJECT-TYPE    
  INTEGER viewOnly(1), fullAccess(2), off(3)  

cmcTcSetupDate 1.3.6.1.4.1.2606.4.3.1.6
actual Date in format DD.MM.YYYY
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

cmcTcSetupTime 1.3.6.1.4.1.2606.4.3.1.7
actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)
OBJECT-TYPE    
  DisplayString SIZE(0..8)  

cmcTcTimerTable1 1.3.6.1.4.1.2606.4.3.1.8
OBJECT IDENTIFIER    

cmcTcTimerNumber 1.3.6.1.4.1.2606.4.3.1.8.1
Number of value-table entries=number of outlets available on this unit
OBJECT-TYPE    
  INTEGER  

cmcTcTimerTable 1.3.6.1.4.1.2606.4.3.1.8.2
Headline of status-table
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcTimerEntry

cmcTcTimerEntry 1.3.6.1.4.1.2606.4.3.1.8.2.1
Entries of timer-table
OBJECT-TYPE    
  CmcTcTimerEntry  

cmcTcTimerIndex 1.3.6.1.4.1.2606.4.3.1.8.2.1.1
Index for the list of timer entries. Its value ranges between 1 and the value of cmcTcTimerNumber.
OBJECT-TYPE    
  INTEGER 1..65535  

cmcTcTimerStatus 1.3.6.1.4.1.2606.4.3.1.8.2.1.2
Actual status of the timer
OBJECT-TYPE    
  INTEGER switchedOff(1), switchedOn(2), noTime(3)  

cmcTcTimerDayOfWeek 1.3.6.1.4.1.2606.4.3.1.8.2.1.3
Selection of day of week for timer to switch
OBJECT-TYPE    
  INTEGER sun(1), mon(2), tue(3), wed(4), thu(5), fri(6), sat(7), sat-sun(8), mon-fri(9), mon-sun(10)  

cmcTcTimeOn 1.3.6.1.4.1.2606.4.3.1.8.2.1.4
Time to switch on current function, Format: HH:MM
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cmcTcTimeOff 1.3.6.1.4.1.2606.4.3.1.8.2.1.5
Time to switch off current function, Format: HH:MM
OBJECT-TYPE    
  DisplayString SIZE(0..5)  

cmcTcTimeControl 1.3.6.1.4.1.2606.4.3.1.8.2.1.6
Control via RTC
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cmcTcTimerFunction 1.3.6.1.4.1.2606.4.3.1.8.2.1.7
Function which is controlled via timer 1: unlock via keypad 1 on unit 1 or remote input lock 1 is disabled 2: unlock via keypad 2 on unit 1 or remote input lock 2 is disabled 3 unlock via keypad 1 on unit 2 or remote input lock 1 is disabled 4: unlock via keypad 2 on unit 2 or remote input lock 2 is disabled 5: unlock via keypad 1 on unit 3 or remote input lock 1 is disabled 6: unlock via keypad 2 on unit 3 or remote input lock 2 is disabled 7: unlock via keypad 1 on unit 4 or remote input lock 1 is disabled 8: unlock via keypad 2 on unit 4 or remote input lock 2 is disabled 9: Lock of door 1 on unit 1 will be unlocked 10: Lock of door 2 on unit 1 will be unlocked 11: Lock of door 1 on unit 2 will be unlocked 12: Lock of door 2 on unit 2 will be unlocked 13: Lock of door 1 on unit 3 will be unlocked 14: Lock of door 2 on unit 3 will be unlocked 15: Lock of door 1 on unit 4 will be unlocked 16: Lock of door 2 on unit 4 will be unlocked 17-20: sending Traps to this Trap receiver will be disabled
OBJECT-TYPE    
  INTEGER disKeypad1-1(1), disKeypad2-1(2), disKeypad1-2(3), disKeypad2-2(4), disKeypad1-3(5), disKeypad2-3(6), disKeypad1-4(7), disKeypad2-4(8), unlDoor1-1(9), unlDoor2-1(10), unlDoor1-2(11), unlDoor2-2(12), unlDoor1-3(13), unlDoor2-3(14), unlDoor1-4(15), unlDoor2-5(16), disTrapRec1(17), disTrapRec2(18), disTrapRec3(19), disTrapRec4(20)  

cmcTcTrapControl 1.3.6.1.4.1.2606.4.4
OBJECT IDENTIFIER    

alarmSensorUnit4 1.3.6.1.4.1.2606.4.4
Alarm of sensor unit 4
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  unit4MsgIndex  
  unit4MsgText  
  unit4MsgStatus  
  unit4SensorValue  

cmcTcTraps 1.3.6.1.4.1.2606.4.4.7
OBJECT IDENTIFIER    

cmcTcTraptableNumber 1.3.6.1.4.1.2606.4.4.7.1
Number of trapTable entries. The number of trap-receiver
OBJECT-TYPE    
  INTEGER  

cmcTcTrapTableTable 1.3.6.1.4.1.2606.4.4.7.2
A list of trap-receiver entries
OBJECT-TYPE    
  SEQUENCE OF  
    CmcTcTrapTableEntry

cmcTcTrapTableEntry 1.3.6.1.4.1.2606.4.4.7.2.1
Entries of trapTable
OBJECT-TYPE    
  CmcTcTrapTableEntry  

trapIndex 1.3.6.1.4.1.2606.4.4.7.2.1.1
Index for the trap-receiver-table. Its value ranges between 1 and the value of traptableNumber
OBJECT-TYPE    
  INTEGER 1..65535  

trapStatus 1.3.6.1.4.1.2606.4.4.7.2.1.2
Enable or disable trap receiver
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

trapIPaddress 1.3.6.1.4.1.2606.4.4.7.2.1.3
IP-address of trap-receiver
OBJECT-TYPE    
  DisplayString SIZE(0..15)  

cmcTcControl 1.3.6.1.4.1.2606.4.5
OBJECT IDENTIFIER    

alarmUnit1 1.3.6.1.4.1.2606.4.5
Alarm of unit 1
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  cmcTcUnit1Text  
  cmcTcUnit1Status  

cmcTcQuitUnit 1.3.6.1.4.1.2606.4.5.1
Command to quit (acknowledge) alarms of CMC-TC unit. Setting to 'quit' (2) will have same result as pressing 'C' on Units. Variable is automatically set back to 'noQuit' (1).
OBJECT-TYPE    
  INTEGER noQuit(1), quit(2)  

alarmUnit2 1.3.6.1.4.1.2606.4.6
Alarm of unit 2
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  cmcTcUnit2Text  
  cmcTcUnit2Status  

alarmUnit3 1.3.6.1.4.1.2606.4.7
Alarm of unit 3
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  cmcTcUnit3Text  
  cmcTcUnit3Status  

alarmUnit4 1.3.6.1.4.1.2606.4.8
Alarm of unit 4
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  cmcTcUnit4Text  
  cmcTcUnit4Status  

alarmValues 1.3.6.1.4.1.2606.4.9
Alarm of values measured by external card
TRAP-TYPE    
  sysContact  
  sysName  
  sysLocation  
  valuesIndex  
  valuesText  
  valuesStatus  

configChanged 1.3.6.1.4.1.2606.4.10
The configuration of the cmc has changed, this trap is send if new setup is saved. Configuration can be changed by Terminal, Telnet, Web or SNMP *** NOT IMPLEMENTED ***
TRAP-TYPE    
  sysDescr  
  sysContact  
  sysName  
  sysLocation  

Defined Objects

CmcTcUnit1SensorEntry  
SEQUENCE    
  INTEGER as unit1SensorIndex  
  INTEGER as unit1SensorType  
  DisplayString as unit1SensorText SIZE(0..20)  
  INTEGER as unit1SensorStatus  
  INTEGER as unit1SensorValue  
  INTEGER as unit1SensorSetHigh  
  INTEGER as unit1SensorSetLow  
  INTEGER as unit1SensorSetWarn  

CmcTcUnit1OutputEntry  
SEQUENCE    
  INTEGER as unit1OutputIndex  
  INTEGER as unit1OutputType  
  DisplayString as unit1OutputText SIZE(0..20)  
  INTEGER as unit1OutputStatus  
  INTEGER as unit1OutputValue  
  INTEGER as unit1OutputSet  
  INTEGER as unit1OutputConfig  
  INTEGER as unit1OutputDelay  
  INTEGER as unit1OutputTimeoutAction  

CmcTcUnit1MsgEntry  
SEQUENCE    
  INTEGER as unit1MsgIndex  
  DisplayString as unit1MsgText SIZE(0..20)  
  INTEGER as unit1MsgStatus  
  INTEGER as unit1MsgRelay  
  INTEGER as unit1MsgBeeper  
  INTEGER as unit1MsgTrap1  
  INTEGER as unit1MsgTrap2  
  INTEGER as unit1MsgTrap3  
  INTEGER as unit1MsgTrap4  
  INTEGER as unit1MsgQuit  

CmcTcUnit2SensorEntry  
SEQUENCE    
  INTEGER as unit2SensorIndex  
  INTEGER as unit2SensorType  
  DisplayString as unit2SensorText SIZE(0..20)  
  INTEGER as unit2SensorStatus  
  INTEGER as unit2SensorValue  
  INTEGER as unit2SensorSetHigh  
  INTEGER as unit2SensorSetLow  
  INTEGER as unit2SensorSetWarn  

CmcTcUnit2OutputEntry  
SEQUENCE    
  INTEGER as unit2OutputIndex  
  INTEGER as unit2OutputType  
  DisplayString as unit2OutputText SIZE(0..20)  
  INTEGER as unit2OutputStatus  
  INTEGER as unit2OutputValue  
  INTEGER as unit2OutputSet  
  INTEGER as unit2OutputConfig  
  INTEGER as unit2OutputDelay  
  INTEGER as unit2OutputTimeoutAction  

CmcTcUnit2MsgEntry  
SEQUENCE    
  INTEGER as unit2MsgIndex  
  DisplayString as unit2MsgText SIZE(0..20)  
  INTEGER as unit2MsgStatus  
  INTEGER as unit2MsgRelay  
  INTEGER as unit2MsgBeeper  
  INTEGER as unit2MsgTrap1  
  INTEGER as unit2MsgTrap2  
  INTEGER as unit2MsgTrap3  
  INTEGER as unit2MsgTrap4  
  INTEGER as unit2MsgQuit  

CmcTcUnit3SensorEntry  
SEQUENCE    
  INTEGER as unit3SensorIndex  
  INTEGER as unit3SensorType  
  DisplayString as unit3SensorText SIZE(0..20)  
  INTEGER as unit3SensorStatus  
  INTEGER as unit3SensorValue  
  INTEGER as unit3SensorSetHigh  
  INTEGER as unit3SensorSetLow  
  INTEGER as unit3SensorSetWarn  

CmcTcUnit3OutputEntry  
SEQUENCE    
  INTEGER as unit3OutputIndex  
  INTEGER as unit3OutputType  
  DisplayString as unit3OutputText SIZE(0..20)  
  INTEGER as unit3OutputStatus  
  INTEGER as unit3OutputValue  
  INTEGER as unit3OutputSet  
  INTEGER as unit3OutputConfig  
  INTEGER as unit3OutputDelay  
  INTEGER as unit3OutputTimeoutAction  

CmcTcUnit3MsgEntry  
SEQUENCE    
  INTEGER as unit3MsgIndex  
  DisplayString as unit3MsgText SIZE(0..20)  
  INTEGER as unit3MsgStatus  
  INTEGER as unit3MsgRelay  
  INTEGER as unit3MsgBeeper  
  INTEGER as unit3MsgTrap1  
  INTEGER as unit3MsgTrap2  
  INTEGER as unit3MsgTrap3  
  INTEGER as unit3MsgTrap4  
  INTEGER as unit3MsgQuit  

CmcTcUnit4SensorEntry  
SEQUENCE    
  INTEGER as unit4SensorIndex  
  INTEGER as unit4SensorType  
  DisplayString as unit4SensorText SIZE(0..20)  
  INTEGER as unit4SensorStatus  
  INTEGER as unit4SensorValue  
  INTEGER as unit4SensorSetHigh  
  INTEGER as unit4SensorSetLow  
  INTEGER as unit4SensorSetWarn  

CmcTcUnit4OutputEntry  
SEQUENCE    
  INTEGER as unit4OutputIndex  
  INTEGER as unit4OutputType  
  DisplayString as unit4OutputText SIZE(0..20)  
  INTEGER as unit4OutputStatus  
  INTEGER as unit4OutputValue  
  INTEGER as unit4OutputSet  
  INTEGER as unit4OutputConfig  
  INTEGER as unit4OutputDelay  
  INTEGER as unit4OutputTimeoutAction  

CmcTcUnit4MsgEntry  
SEQUENCE    
  INTEGER as unit4MsgIndex  
  DisplayString as unit4MsgText SIZE(0..20)  
  INTEGER as unit4MsgStatus  
  INTEGER as unit4MsgRelay  
  INTEGER as unit4MsgBeeper  
  INTEGER as unit4MsgTrap1  
  INTEGER as unit4MsgTrap2  
  INTEGER as unit4MsgTrap3  
  INTEGER as unit4MsgTrap4  
  INTEGER as unit4MsgQuit  

CmcTcValuesEntry  
SEQUENCE    
  INTEGER as valuesIndex  
  DisplayString as valuesText SIZE(0..20)  
  INTEGER as valuesStatus  
  INTEGER as valuesValue  
  INTEGER as valuesSetHigh  
  INTEGER as valuesSetLow  

CmcTcTimerEntry  
SEQUENCE    
  INTEGER as cmcTcTimerIndex  
  INTEGER as cmcTcTimerStatus  
  INTEGER as cmcTcTimerDayOfWeek  
  DisplayString as cmcTcTimeOn SIZE(0..5)  
  DisplayString as cmcTcTimeOff SIZE(0..5)  
  INTEGER as cmcTcTimeControl  
  INTEGER as cmcTcTimerFunction  

CmcTcTrapTableEntry  
SEQUENCE    
  INTEGER as trapIndex  
  INTEGER as trapStatus  
  DisplayString as trapIPaddress