RIVERSTONE-IF-MIB

File: RIVERSTONE-IF-MIB.mib (24695 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
SNMP-FRAMEWORK-MIB IF-MIB RIVERSTONE-TC-MIB
RIVERSTONE-SMI-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Counter64 Integer32 Unsigned32
Gauge32 TEXTUAL-CONVENTION TimeStamp
TruthValue MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP SnmpAdminString ifIndex
RsQueuePolicy riverstoneMibs

Defined Objects

rsIfMIB 1.3.6.1.4.1.5567.2.60
This MIB module extends the IF-MIB.
MODULE-IDENTITY    

rsIfMIBObjects 1.3.6.1.4.1.5567.2.60.1
OBJECT IDENTIFIER    

rsIfStatsTable 1.3.6.1.4.1.5567.2.60.1.1
This table contains additional information for interfaces in the ifTable. An interface would be included in this table only if the value of its ifConnectorPresent is true.
OBJECT-TYPE    
  SEQUENCE OF  
    RsIfStatsEntry

rsIfStatsEntry 1.3.6.1.4.1.5567.2.60.1.1.1
This entry provides additional information for the corresponding interface in the ifTable. Discontinuities in the values of this row can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. The objects in this entry complement other counters in IF-MIB, P/Q-BRIDGE-MIB, EtherLike-MIB. RMON-MIB
OBJECT-TYPE    
  RsIfStatsEntry  

rsIfStatsCapability 1.3.6.1.4.1.5567.2.60.1.1.1.1
The validity of each counter in this table. Each bit refers to one counter. This object indicates if each counter in the row is supported.
OBJECT-TYPE    
  BITS ifTotalUpTime(0), ifTotalDownTime(1), ifUpTransitions(2), ifDownTransitions(3), ifInCorrelatedLayer1Errors(4), ifInBridgedOctets(5), ifInLocalFrames(6), ifInL2TableMisses(7), ifInRoutedOctets(8), ifInRoutedSwitchedPackets(9), ifInRoutedCpuPackets(10), ifInIpTableMisses(11), ifInInvalidMacEncap(12), ifInVlanTableDiscards(13), ifOutBridgedOctets(14), ifOutRoutedOctets(15), ifOutVlanTableDiscards(16)  

rsIfQueuePolicy 1.3.6.1.4.1.5567.2.60.1.1.1.2
The queuing policy used on this physical interface. On the RS platform, the user can see the queue policy by entering: 'qos show weighted-fair port ' in enabled mode.
OBJECT-TYPE    
  RsQueuePolicy  

rsIfMru 1.3.6.1.4.1.5567.2.60.1.1.1.3
The size of the largest frame which can be received by this physical network interface for a specific media type. Frames received that are larger than this size will be dropped and the generic ifInErrors counter will be incremented. Depending on the interface type, a specific (too big) counter will be incremented such as dot3StatsFrameTooLongs. On the RS platform, the user can see the MRU by entering: 'port show mtu ' in enabled mode.
OBJECT-TYPE    
  Integer32  

rsIfForceEtherIIState 1.3.6.1.4.1.5567.2.60.1.1.1.4
The object indicates if the port is configured to force input encapsulation to be interpreted as 'Ethernet II'. If the value is false, this means the port is not an Ethernet port or the Ethernet port is not forcing this input encapsulation. On the RS platform, the user can check for the line 'port set input-encapsulation forced-ethernet_ii' in config mode.
OBJECT-TYPE    
  TruthValue  

rsIfTotalUpTime 1.3.6.1.4.1.5567.2.60.1.1.1.5
The amount of time since the router boots up for which the interface is up. The sum of rsIfTotalUpTime and rsIfTotalDownTime is equal to sysUpTime.
OBJECT-TYPE    
  Counter32  

rsIfTotalDownTime 1.3.6.1.4.1.5567.2.60.1.1.1.6
The amount of time since the router boots up for which the interface is down. The sum of rsIfTotalUpTime and rsIfTotalDownTime is equal to sysUpTime.
OBJECT-TYPE    
  Counter32  

rsIfUpTransitions 1.3.6.1.4.1.5567.2.60.1.1.1.7
The number of times this interface has changed from link-down to link-up.
OBJECT-TYPE    
  Counter32  

rsIfDownTransitions 1.3.6.1.4.1.5567.2.60.1.1.1.8
The number of times this interface has changed from link-up to link-down.
OBJECT-TYPE    
  Counter32  

rsIfInCorrelatedLayer1Errors 1.3.6.1.4.1.5567.2.60.1.1.1.9
The number of frames in error due to physical signal degradation. This counter is a close approximation of the actual number of frames dropped due to layer 1 errors. An empirical experiment was done to correlate the registers to the actual frames dropped in a controlled environment that simulates physical signal degradation. On the RS platform, a number of hardware registers were identified that approximate the actual number of frames dropped. The registers would be different for the different interfaces on the RS platform. Usually on WAN interface, this counter is not supported. Refer to the value of rsIfStatsCapability to determine if this interface supports this counter.
OBJECT-TYPE    
  Counter32  

rsIfInBridgedOctets 1.3.6.1.4.1.5567.2.60.1.1.1.10
The number of bridged octets that are received by this interface. The sum of rsIfInBridgedOctets and rsIfInRoutedOctets is equal to ifInOctets. This object is similar to dot1dTpHCPortInFrames, but bytes are counted instead of frames.
OBJECT-TYPE    
  Counter64  

rsIfInLocalFrames 1.3.6.1.4.1.5567.2.60.1.1.1.11
The number of frames whose destination address is a local MAC address and whose etype is of L2 variety.
OBJECT-TYPE    
  Counter64  

rsIfInL2TableMisses 1.3.6.1.4.1.5567.2.60.1.1.1.12
The number of times that there is no entry in the Forwarding Database. As a result, this frame would go to a CPU.
OBJECT-TYPE    
  Counter64  

rsIfInRoutedOctets 1.3.6.1.4.1.5567.2.60.1.1.1.13
The number of routed octets received by this interface. The sum of rsIfInBridgedOctets and rsIfInRoutedOctets is equal to ifInOctets.
OBJECT-TYPE    
  Counter64  

rsIfInRoutedSwitchedPackets 1.3.6.1.4.1.5567.2.60.1.1.1.14
The number of IP packets that were switched through the fabric without going to the CPU. On the RS platform with HRT disabled, when the L3 flow table does not have a flow entry for a packet, the first packet for the flow would go to the CPU first to establish a flow entry.
OBJECT-TYPE    
  Counter64  

rsIfInRoutedCpuPackets 1.3.6.1.4.1.5567.2.60.1.1.1.15
The number of IP packets sent to the CPU. This counter would increase when a packet is destined to the CPU and the L3 table has its flow entry.
OBJECT-TYPE    
  Counter64  

rsIfInIpTableMisses 1.3.6.1.4.1.5567.2.60.1.1.1.16
The number of times that an appropriate flow for the packet is not found in the L3 flow table. As a result, this packet goes to the CPU to create a L3 flow entry. On the RS platform with HRT mode enabled, the packet would not go to the CPU.
OBJECT-TYPE    
  Counter64  

rsIfInInvalidMacEncap 1.3.6.1.4.1.5567.2.60.1.1.1.17
The number of frames received by this interface that used invalid MAC encapsulation.
OBJECT-TYPE    
  Counter32  

rsIfInVlanTableDiscards 1.3.6.1.4.1.5567.2.60.1.1.1.18
The number of frames received by this interface that were discarded due to VLAN related reasons. This object is similar to dot1qTpVlanPortInDiscards. It would have the same value if this interface belongs to only one VLAN. On some interfaces, this object is not valid. Refer to the value of rsIfStatsCapability to check its validity.
OBJECT-TYPE    
  Counter32  

rsIfOutBridgedOctets 1.3.6.1.4.1.5567.2.60.1.1.1.19
The number of bridged octets that are transmitted by this interface. This object is similar to dot1dTpHCPortInFrames, but bytes are counted instead of frames.
OBJECT-TYPE    
  Counter64  

rsIfOutRoutedOctets 1.3.6.1.4.1.5567.2.60.1.1.1.20
The number of routed octets transmitted by this interface. The sum of rsIfOutBridgedOctets and rsIfOutRoutedOctets is equal to ifOutOctets.
OBJECT-TYPE    
  Counter64  

rsIfOutVlanTableDiscards 1.3.6.1.4.1.5567.2.60.1.1.1.21
The number of frames to be transmitted by this interface but were discarded due to VLAN related reasons. This object is similar to dot1qTpVlanPortOutDiscards. It would have the same value if this interface belongs to only one VLAN. On some interfaces, this object is not valid. Refer to the value of rsIfStatsCapability to check its validity.
OBJECT-TYPE    
  Counter32  

rsIfGaugeTable 1.3.6.1.4.1.5567.2.60.1.2
This table contains gauges for a port interface.
OBJECT-TYPE    
  SEQUENCE OF  
    RsIfGaugeEntry

rsIfGaugeEntry 1.3.6.1.4.1.5567.2.60.1.2.1
This row contains gauges for a port interface. The number of updates done to caluculate the difference of a gauge in the one minute interval may vary across different software versions. If the updates are infrequent for example every 30 seconds, the user would observe a constant value for that 30 seconds. Discontinuities in the values of this row can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
OBJECT-TYPE    
  RsIfGaugeEntry  

rsIfGaugeCapability 1.3.6.1.4.1.5567.2.60.1.2.1.1
The validity of each object in this table. Each bit refers to one object. This object indicates if each counter in the row is supported.
OBJECT-TYPE    
  BITS ifInOneMinBitsPerSec(0), ifInOneMinPktsDiscards(1), ifInOneMinPktsErrors(2), ifInOneMinUnicastPkts(3), ifInOneMinMulticastPkts(4), ifInOneMinBroadcastPkts(5), ifOutOneMinBitsPerSec(6), ifOutOneMinPktsDiscards(7), ifOutOneMinPktsErrors(8), ifOutOneMinUnicastPkts(9), ifOutOneMinMulticastPkts(10), ifOutOneMinBroadcastPkts(11)  

rsIfInOneMinBitsPerSec 1.3.6.1.4.1.5567.2.60.1.2.1.2
The average receive rate across the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfInOneMinPktsDiscards 1.3.6.1.4.1.5567.2.60.1.2.1.3
The number of packets received by this port that were discarded in the one minute interval before the update. On the RS platform, a reason for discarding the packets would be buffer overflow.
OBJECT-TYPE    
  Gauge32  

rsIfInOneMinPktsErrors 1.3.6.1.4.1.5567.2.60.1.2.1.4
The number of packets with error received by this port in the one minute interval before the update. On the RS platform, the number of received packets with 'error' is a sum of: frames with invalid MAC encapsulation, oversize frames, jabbers, undersize frames, frames with bad alignment, frames with bad CRC, internal frame error, input VLAN dropped frames, carrier sense error frames.
OBJECT-TYPE    
  Gauge32  

rsIfInOneMinUnicastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.5
The number of unicast packets received by this port in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfInOneMinMulticastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.6
The number of multicast packets received by this port in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfInOneMinBroadcastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.7
The number of broadcast packets received by this port in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinBitsPerSec 1.3.6.1.4.1.5567.2.60.1.2.1.8
The average transmit rate across the one minute. before the update.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinPktsDiscards 1.3.6.1.4.1.5567.2.60.1.2.1.9
The number of packets to be transmitted that were discarded by the port interface in the minute before the update. On the RS platform, a reason for discarding the packets would be buffer overflow.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinPktsErrors 1.3.6.1.4.1.5567.2.60.1.2.1.10
The number of packets to be transmitted but may or may not have been discarded by the port interface because of 'error' in the one minute interval before the update. On the RS platform, the number of packets with 'error' is a sum of: single collision frames, multiple collision frames, frames dropped because of collisions, deferred transmissions, late collision frames, underruns, internal transmit errors.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinUnicastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.11
The number of unicast packets transmitted in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinMulticastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.12
The number of multicast packets transmitted in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfOutOneMinBroadcastPkts 1.3.6.1.4.1.5567.2.60.1.2.1.13
The number of broadcast packets transmitted in the one minute interval before the update.
OBJECT-TYPE    
  Gauge32  

rsIfConformance 1.3.6.1.4.1.5567.2.60.2
OBJECT IDENTIFIER    

rsIfCompliances 1.3.6.1.4.1.5567.2.60.2.1
OBJECT IDENTIFIER    

rsIfCompliance 1.3.6.1.4.1.5567.2.60.2.1.1
The compliance statement for RIVERSTONE-STATS-MIB.
MODULE-COMPLIANCE    

rsIfGroups 1.3.6.1.4.1.5567.2.60.2.2
OBJECT IDENTIFIER    

rsIfStatsGroup 1.3.6.1.4.1.5567.2.60.2.2.1
The collection of objects representing additional port interface counters and state data.
OBJECT-GROUP    

rsIfGaugeGroup 1.3.6.1.4.1.5567.2.60.2.2.2
The collection of objects representing port interface gauges.
OBJECT-GROUP    

Defined Objects

RsIfStatsEntry  
SEQUENCE    
  BITS as rsIfStatsCapability  
  RsQueuePolicy as rsIfQueuePolicy  
  Integer32 as rsIfMru  
  TruthValue as rsIfForceEtherIIState  
  Counter32 as rsIfTotalUpTime  
  Counter32 as rsIfTotalDownTime  
  Counter32 as rsIfUpTransitions  
  Counter32 as rsIfDownTransitions  
  Counter32 as rsIfInCorrelatedLayer1Errors  
  Counter64 as rsIfInBridgedOctets  
  Counter64 as rsIfInLocalFrames  
  Counter64 as rsIfInL2TableMisses  
  Counter64 as rsIfInRoutedOctets  
  Counter64 as rsIfInRoutedSwitchedPackets  
  Counter64 as rsIfInRoutedCpuPackets  
  Counter64 as rsIfInIpTableMisses  
  Counter32 as rsIfInInvalidMacEncap  
  Counter32 as rsIfInVlanTableDiscards  
  Counter64 as rsIfOutBridgedOctets  
  Counter64 as rsIfOutRoutedOctets  
  Counter32 as rsIfOutVlanTableDiscards  

RsIfGaugeEntry  
SEQUENCE    
  BITS as rsIfGaugeCapability  
  Gauge32 as rsIfInOneMinBitsPerSec  
  Gauge32 as rsIfInOneMinPktsDiscards  
  Gauge32 as rsIfInOneMinPktsErrors  
  Gauge32 as rsIfInOneMinUnicastPkts  
  Gauge32 as rsIfInOneMinMulticastPkts  
  Gauge32 as rsIfInOneMinBroadcastPkts  
  Gauge32 as rsIfOutOneMinBitsPerSec  
  Gauge32 as rsIfOutOneMinPktsDiscards  
  Gauge32 as rsIfOutOneMinPktsErrors  
  Gauge32 as rsIfOutOneMinUnicastPkts  
  Gauge32 as rsIfOutOneMinMulticastPkts  
  Gauge32 as rsIfOutOneMinBroadcastPkts