RS366-OPT-MIB

File: RS366-OPT-MIB.mib (11325 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

enterprises OBJECT-TYPE

Defined Objects

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PPCTRS366PortTable 1.3.6.1.4.1.449.2.1.2.1.1.21
A list of RS366 Port configuration entries.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTRS366PortEntry

cdx6500PPCTRS366PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.21.1
An RS366 Configuration Table entry. Each entry contains the configuration parameters for a single RS366 port.
OBJECT-TYPE    
  Cdx6500PPCTRS366PortEntry  

cdx6500RS366CfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.21.1.1
Port Number.
OBJECT-TYPE    
  INTEGER 1..52  

cdx6500RS366CfgADataPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.21.1.2
Associated Data Port Number
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500RS366CfgContXferMode 1.3.6.1.4.1.449.2.1.2.1.1.21.1.3
modeEon - Transfer control after end of number digit detected. modeEbt - Transfer control after maximum address digits accumulated and answerback tone is received. newvalModeNull - same functionality as 'modeNull', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER modenull(0), modeeon(1), modeebt(2), newvalmodenull(50)  

cdx6500RS366CfgMaxAddrDigits 1.3.6.1.4.1.449.2.1.2.1.1.21.1.4
Number of digits required to transfer control in EBT mode. This parameter is not required in EON mode and it is set to 15 irrespective of the user entry.
OBJECT-TYPE    
  INTEGER 1..15  

cdx6500RS366CfgMaxRespTime 1.3.6.1.4.1.449.2.1.2.1.1.21.1.5
Maximum EIA response time in seconds before a timeout can occur. sec0 - Indicates response time out should be disabled. sec32 - Maximum EIA response time is 32 seconds. sec48 - Maximum EIA response time is 48 seconds. sec96 - Maximum EIA response time is 96 seconds. newvalSec0 - same functionality as 'sec0', new enumeration added for RFC1155 compatibility.
OBJECT-TYPE    
  INTEGER sec0(0), sec32(32), sec48(48), sec96(96), newvalSec0(50)  

cdx6500RS366CfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.21.1.6
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500RS366CfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.21.1.7
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500RS366CfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.21.1.8
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PPSTRS366PortTable 1.3.6.1.4.1.449.2.1.3.1.1.22
A list of RS366 Port statistics.
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTRS366PortEntry

cdx6500PPSTRS366PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.22.1
An RS366 Statistics Table entry. Each entry contains the statistics for a single RS366 port.
OBJECT-TYPE    
  Cdx6500PPSTRS366PortEntry  

cdx6500RS366StatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.22.1.1
Port Number.
OBJECT-TYPE    
  INTEGER 1..52  

cdx6500RS366StatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.22.1.2
Enabled or Disabled.
OBJECT-TYPE    
  DisplayString  

cdx6500RS366StatPortState 1.3.6.1.4.1.449.2.1.3.1.1.22.1.3
Port State.
OBJECT-TYPE    
  DisplayString  

cdx6500RS366StatDataNum 1.3.6.1.4.1.449.2.1.3.1.1.22.1.4
Data Port Number.
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalCalls 1.3.6.1.4.1.449.2.1.3.1.1.22.1.5
Number of calls made.
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatFailedCalls 1.3.6.1.4.1.449.2.1.3.1.1.22.1.6
Number of failed calls.
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalTimeouts 1.3.6.1.4.1.449.2.1.3.1.1.22.1.7
Number of protocol time-outs.
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatTotalIllegalDigits 1.3.6.1.4.1.449.2.1.3.1.1.22.1.8
Number of illegal digits received.
OBJECT-TYPE    
  INTEGER  

cdx6500RS366StatPortConnected 1.3.6.1.4.1.449.2.1.3.1.1.22.1.9
Connected to Data Port.
OBJECT-TYPE    
  DisplayString  

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

Defined Objects

DisplayString  
OCTET STRING    

Cdx6500PPCTRS366PortEntry  
SEQUENCE    
  INTEGER as cdx6500RS366CfgPortNumber  
  INTEGER as cdx6500RS366CfgADataPortNumber  
  INTEGER as cdx6500RS366CfgContXferMode  
  INTEGER as cdx6500RS366CfgMaxAddrDigits  
  INTEGER as cdx6500RS366CfgMaxRespTime  
  INTEGER as cdx6500RS366CfgElectricalInterfaceType  
  INTEGER as cdx6500RS366CfgV24ElectricalInterfaceOption  
  INTEGER as cdx6500RS366CfgHighSpeedElectricalInterfaceOption  

Cdx6500PPSTRS366PortEntry  
SEQUENCE    
  INTEGER as cdx6500RS366StatPortNumber  
  DisplayString as cdx6500RS366StatPortStatus  
  DisplayString as cdx6500RS366StatPortState  
  INTEGER as cdx6500RS366StatDataNum  
  INTEGER as cdx6500RS366StatTotalCalls  
  INTEGER as cdx6500RS366StatFailedCalls  
  INTEGER as cdx6500RS366StatTotalTimeouts  
  INTEGER as cdx6500RS366StatTotalIllegalDigits  
  DisplayString as cdx6500RS366StatPortConnected