SALIX-HNE-MIB

File: SALIX-HNE-MIB.mib (81531 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB SONET-MIB ATM-MIB
ATM-FORUM-M4-MIB ENTITY-MIB HOST-RESOURCES-MIB
SALIX-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 Counter64 Gauge32
IpAddress TEXTUAL-CONVENTION DisplayString
RowStatus TruthValue DateAndTime
MODULE-COMPLIANCE OBJECT-GROUP InterfaceIndex
ifIndex sonetMediumEntry sonetPathCurrentEntry
sonetLineCurrentEntry sonetSectionCurrentEntry sonetPathIntervalEntry
sonetLineIntervalEntry sonetSectionIntervalEntry AtmTrafficDescrParamIndex
atmInterfaceConfEntry atmVplEntry atmVclEntry
atmVclVci atmVclVpi atmVplVpi
atmfM4TcAdaptorEntry atmfM4EquipHolderEntry atmfM4PlugInUnitEntry
atmfM4CellProtoHistIndex entPhysicalIndex PhysicalIndex
hrSWInstalledEntry hrSWInstalledIndex hybridSwitch

Defined Objects

hneMIB 1.3.6.1.4.1.2158.3.1.1
The HNE enterprise specific MIB
MODULE-IDENTITY    

hneMIBObjects 1.3.6.1.4.1.2158.3.1.1.1
OBJECT IDENTIFIER    

hneSystem 1.3.6.1.4.1.2158.3.1.1.1.1
OBJECT IDENTIFIER    

hneSystemHost 1.3.6.1.4.1.2158.3.1.1.1.1.1
OBJECT IDENTIFIER    

hneSystemSync 1.3.6.1.4.1.2158.3.1.1.1.1.2
OBJECT IDENTIFIER    

hneSysSyncTimingMode 1.3.6.1.4.1.2158.3.1.1.1.1.2.1
An identification of the source from which timing is derived by the working sync module within the HNE. Possible values are: internal(1) - the internal oscillator on the sync module will be used as the master clock for system synchronization. line(2) - the sync module is synchronizing with the receive line timing from a signal received by an LIU. external(3) - the Building Integrated Timing System (BITS) available on a T1 line plugged into an LIU will be used as the master clock for system synchronization.
OBJECT-TYPE    
  INTEGER internal(1), line(2), external(3)  

hneSysSyncPrimaryRefLine 1.3.6.1.4.1.2158.3.1.1.1.1.2.2
The interface index of the primary physical line termination point (SONET line) from which the sync module can derive timing. This is used only if the hneSysSyncTimingMode is set to 'line'.
OBJECT-TYPE    
  InterfaceIndex  

hneSysSyncSecondaryRefLine 1.3.6.1.4.1.2158.3.1.1.1.1.2.3
The interface index of the secondary physical line termination point (SONET line) from which the sync module can derive timing. This is used only if the hneSysSyncTimingMode is set to 'line', and the primary reference is unavailable or out of a valid frequency range.
OBJECT-TYPE    
  InterfaceIndex  

hneSysSyncRevertiveSwitch 1.3.6.1.4.1.2158.3.1.1.1.1.2.4
Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is cleared. true(1) - reference switching is revertive false(2) - reference switching is non-revertive
OBJECT-TYPE    
  TruthValue  

hneSysSyncClockMode 1.3.6.1.4.1.2158.3.1.1.1.1.2.5
Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's internal oscillator. normal(2) - mode in which the clock is synchronized to an external reference. holdover(3) - mode in which the clock, after having been synchronized to an external reference, loses that reference and all other external references. fastStart(4) - mode in which the clock is in the process of synchronizing to a reference.
OBJECT-TYPE    
  INTEGER freeRun(1), normal(2), holdover(3), fastStart(4)  

hneSysSyncConfiguredActiveRef 1.3.6.1.4.1.2158.3.1.1.1.1.2.6
The configured active reference line from which the sync module should deriving its timing. This object is relevant if the hneSysSyncTimingMode is set to 'line' or 'external'. Writing a value that is different from its current value will force the Sync module to switch to using the specified reference line. primary(1) - The hneSysSyncPrimaryRefLine is the active reference line secondary (2) - The hneSysSyncSecondaryRefLine is the active reference line
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

hneSysSyncAutoRefSwitch 1.3.6.1.4.1.2158.3.1.1.1.1.2.7
Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - Auto reference switching is disabled
OBJECT-TYPE    
  TruthValue  

hneSysSyncFreeRunAlarm 1.3.6.1.4.1.2158.3.1.1.1.1.2.8
Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disabled
OBJECT-TYPE    
  TruthValue  

hneSysSyncWorking 1.3.6.1.4.1.2158.3.1.1.1.1.2.9
The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to this object, a value not equal to the current value, will: - update the hneSysSyncProtect object with the current value of the hneSysSyncWorking object and - activate the specified sync module to start providing the system synchronization signal. A value of 0 indicates that there are no operational or not installed sync modules in the system. Writing zero, an invalid index, or the current value to this object will have no effect. If the working sync module fails, the system will automatically switch to the sync module specified in the hneSysSyncProtect object.
OBJECT-TYPE    
  PhysicalIndex  

hneSysSyncProtect 1.3.6.1.4.1.2158.3.1.1.1.1.2.10
The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 indicates that there is no redundant sync module available or provisioned as a protect module.
OBJECT-TYPE    
  PhysicalIndex  

hneSysSyncPrimaryRefLineState 1.3.6.1.4.1.2158.3.1.1.1.1.2.11
This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by the sync module. This object is relevant if the hneSysSyncTimingMode is set to 'line' and the hneSysSyncPrimaryRefLine is configured. unknown(0) - the state of the line has not been determined. valid(1) - the line is operating within the frequency specification. lossOfSignalError - loss of signal was detected from the line and has failed the health check. frequencyOffsetError - frequency errors were detected from the line and has failed the health check
OBJECT-TYPE    
  INTEGER unknown(0), valid(1), lossOfSignalError(2), frequencyOffsetError(3)  

hneSysSyncSecondaryRefLineState 1.3.6.1.4.1.2158.3.1.1.1.1.2.12
This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by the sync module. This object is relevant if the 'hneSysSyncTimingMode' is set to 'line' and the 'hneSysSyncPrimaryRefLine' is configured. unknown(0) - the state of the line has not been determined. valid(1) - the line is operating within frequency specification. lossOfSignalError - loss of signal was detected from the line and has failed the health check. frequencyOffsetError - frequency errors were detected from the line and has failed the health check
OBJECT-TYPE    
  INTEGER unknown(0), valid(1), lossOfSignalError(2), frequencyOffsetError(3)  

hneSysSyncCurrentActiveRef 1.3.6.1.4.1.2158.3.1.1.1.1.2.13
Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSysSyncTimingMode is set to 'line' or 'external'. The value of this variable can differ from the 'hneSysSyncConfiguredActiveRef' if the sync module determine an error condition with the 'hneSysSyncConfiguredActiveRef' and has switched to using another SONET line as the active reference. primary(1) - The hneSysSyncPrimaryRefLine is the current active reference line secondary (2) - The hneSysSyncSecondaryRefLine is the current active reference line
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

hneSysSyncForcedState 1.3.6.1.4.1.2158.3.1.1.1.1.2.14
This variable indicates the state of the sync module with regard to switching between the configured active reference, the value of the 'hneSysSyncConfiguredActiveRef' variable, and the alternate active reference. The alternate active reference is identified by the 'hneSysSyncPrimaryRefLine' or 'hneSysSyncSecondaryRefLine' that is not configured as the 'hneSysSyncConfiguredActiveRef'. none(0) - the sync module is in a state where it is free to switch between the configured active reference the alternate active reference. revertiveSwitchInhibit - the state of the sync module after switching from the 'hneSysSyncConfiguredActiveRef' to the 'hneSysSyncCurrentActiveRef' when the 'hneSysSyncRevertiveSwitch' is configured as 'false'. In this state the sync module will not revert back to using the 'hneSysSyncConfiguredActiveRef' unless the 'hneSysSyncCurrentActiveRef' has failed and the state of the active reference defined by the 'hneSysSyncConfiguredActiveRef' variable is 'valid'. autoReferenceSwitchInhibit - the state of the sync module when the 'hneSysSyncAutoReferenceSwitch' variable is configured as 'false'. In this state the sync module will not switch to using the alternate active reference unless the 'hneSysSyncCurrentActiveRef' has failed and the state of the alternate active reference is 'valid'.
OBJECT-TYPE    
  INTEGER none(0), revertiveSwitchInhibit(1), autoReferenceSwitchInhbit(2)  

hneSystemHsf 1.3.6.1.4.1.2158.3.1.1.1.1.3
OBJECT IDENTIFIER    

hneSysHsfWorking 1.3.6.1.4.1.2158.3.1.1.1.1.3.1
The PhysicalIndex of the Hybrid Switch Fabric (HSF) module plug-in unit that is performing switching in the HNE. Writing a new value to this variable will: - update the hneHsfProtect object with the current value of the hneHsfWorking object and - activate the specified HSF module to start performing ATM and TDM switching in the system. A value of 0 indicates that there is no operational switch fabric installed in the HNE. Writing zero, an invalid index, or the current value to this object will have no effect. If the working HSF module fails, the system will automatically switch to the HSF module specified in the hneHsfProtect object.
OBJECT-TYPE    
  PhysicalIndex  

hneSysHsfProtect 1.3.6.1.4.1.2158.3.1.1.1.1.3.2
The entPhysicalIndex of the Hybrid Switch Fabric (HSF) module plug-in unit that is protecting or on standby to the working HSF module, hneHSFWorking. A value of 0 indicates that there are no operational or no additional HSF modules present for redundancy.
OBJECT-TYPE    
  PhysicalIndex  

hneSonet 1.3.6.1.4.1.2158.3.1.1.1.2
OBJECT IDENTIFIER    

hneSonetLineTable 1.3.6.1.4.1.2158.3.1.1.1.2.1
The HNE sonet line table. This table augments the sonetMediumTable defined in the Sonet / SDH MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    HneSonetLineEntry

hneSonetLineEntry 1.3.6.1.4.1.2158.3.1.1.1.2.1.1
An entry in the HNE sonet line table. An entry contains HNE specific sonet line information not found in the Sonet / SDH MIB.
OBJECT-TYPE    
  HneSonetLineEntry  

hneSonetLineTimingSource 1.3.6.1.4.1.2158.3.1.1.1.2.1.1.1
The source of timing for the transmitted signal. This must be set to 'loop' in the 'value added' mode of operation. sync(1) - line timing signal generated by the sync module loop(2) - line timing generated by a line looped back to the line input
OBJECT-TYPE    
  INTEGER sync(1), loop(2)  

hneSonetLineDccSelection 1.3.6.1.4.1.2158.3.1.1.1.2.1.1.2
The selection of which DCC to transmit and receive management traffic on. Only one of the two will be used by the HNE at a time. Possible selections are: section(1) - section overhead will carry the DCC line(2) - line overhead will carry the DCC
OBJECT-TYPE    
  INTEGER section(1), line(2)  

hneSonetLineOverheadLoopThroughModeEnabled 1.3.6.1.4.1.2158.3.1.1.1.2.1.1.3
Indicates whether or not the line overhead bytes of a connection should be looped back through to the outbound path. true(1) - loop through mode is enabled false(2) - loop through mode is not enabled
OBJECT-TYPE    
  TruthValue  

hneSonetProtectionTable 1.3.6.1.4.1.2158.3.1.1.1.2.2
Table giving information about SONET protection switching relationships for signals attached to the HNE. Each record describes a relationship between two SONET lines where one is functioning as the backup for the other.
OBJECT-TYPE    
  SEQUENCE OF  
    HneSonetProtectionEntry

hneSonetProtectionEntry 1.3.6.1.4.1.2158.3.1.1.1.2.2.1
An entry in the HNE protection switching table. An entry contains configuration switching information for the high and low protected interface pair.
OBJECT-TYPE    
  HneSonetProtectionEntry  

hneSonetProtectionInterfaceHigh 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.1
The ifIndex of one of the SONET lines involved in the relationship.
OBJECT-TYPE    
  InterfaceIndex  

hneSonetProtectionInterfaceLow 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.2
The ifIndex of the other SONET lines involved in the relationship.
OBJECT-TYPE    
  InterfaceIndex  

hneSonetProtectionInterfaceWorking 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.3
The ifIndex of the SONET line which is currently carrying live traffic, termed the working or active interface. Writing the value of the protect ifIndex to this value will cause a protection switch.
OBJECT-TYPE    
  InterfaceIndex  

hneSonetProtectionConfig 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.4
The linear APS configuration for the protection relationship. See GR-253-CORE for details.
OBJECT-TYPE    
  INTEGER none(0), onePlusOne(1), oneToOne(2), oneToN(3)  

hneSonetProtectionRevertive 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5
Indication of whether or not the role of 'working' should return after a failure is cleared. See GR-253-CORE. true(1) - protection switching is revertive false(2) - protection switching is non-revertive
OBJECT-TYPE    
  TruthValue  

hneSonetProtectionBiDirectional 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.6
Indication of whether or not protection switching is coordinated on an end-to-end basis or not. If bi-directional, both the east-west and west-east fibers are switched simultaneously. If not, switching on the two fibers is totally independant. true(1) - protection switching is bi-directional false(2) - protection switching is uni-directional
OBJECT-TYPE    
  TruthValue  

hneSonetPathTable 1.3.6.1.4.1.2158.3.1.1.1.2.3
The HNE sonet path table. This table augments the sonetPathCurrentTable defined in the Sonet / SDH MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    HneSonetPathEntry

hneSonetPathEntry 1.3.6.1.4.1.2158.3.1.1.1.2.3.1
An entry in the HNE sonet path table. An entry contains HNE specific sonet path information not found in the Sonet / SDH MIB.
OBJECT-TYPE    
  HneSonetPathEntry  

hneSonetPathContentType 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.1
The type of traffic that is being carried by the sonet path atm(1) - atm cells atmVam(2) - atm value added mode notTerminated(3) - the path is cross-connected through the HNE without being terminated. terminatedNotSpecified(4) - payload of the path is unknown.
OBJECT-TYPE    
  INTEGER atm(1), atmVam(2), notTerminated(3), terminatedNotSpecified(4)  

hneSonetPathOverheadLoopThroughModeEnabled 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.2
Indicates whether or not the path overhead bytes of a connection should be looped back through to the outbound path. true(1) - loop through mode is enabled false(2) - loop through mode is not enabled
OBJECT-TYPE    
  TruthValue  

hneSonetPathSpeMicMode 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.3
Indicates whether or not the SPE MIC should be calculated and inserted in the F2 user byte of the Path overhead. none(0) - SPE MIC is insertion is disabled receive(1) - SPE MIC is inserted only in the receive path transmit(2) - SPE MIC is inserted only in the transmit path receiveTransmit(3) - SPE MIC is inserted in both receive and transmit paths.
OBJECT-TYPE    
  INTEGER none(0), receive(1), transmit(2), receiveTransmit(3)  

hneSonetPathReceiveTraceMessage 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.4
The 64 byte character path trace message expected to be received in the sonet frame path overhead (J1 byte).
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

hneSonetPathTransmitTraceMessage 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.5
The 64 byte character path trace message to be sent in the sonet frame path overhead (J1 byte).
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

hneSonetPathRowStatus 1.3.6.1.4.1.2158.3.1.1.1.2.3.1.6
The status of this entry in the hneSonetPathTable. This object is used to create or delete a hneSonetPathTable entry and the corresponding sonetPathCurrentTable entry defined in the Sonet / SDH MIB. This object must be set to 'createAndGo' to create a new entry in this table. Row status values: active(1) - set by the agent after this entry is created notInService(2) - not applicable notReady(3) - not applicable createAndGo(4) - set by management entity when creating entry createAndWait(5)- not applicable destroy(6) - set by the management entity to destroy entry
OBJECT-TYPE    
  RowStatus  

hneTdm 1.3.6.1.4.1.2158.3.1.1.1.3
OBJECT IDENTIFIER    

hneTdmCrossConnectTable 1.3.6.1.4.1.2158.3.1.1.1.3.1
The HNE TDM cross connect table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneTdmCrossConnectEntry

hneTdmCrossConnectEntry 1.3.6.1.4.1.2158.3.1.1.1.3.1.1
An entry in the HNE TDM cross connect table.
OBJECT-TYPE    
  HneTdmCrossConnectEntry  

hneTdmCrossConnectPathTerminationPoint1 1.3.6.1.4.1.2158.3.1.1.1.3.1.1.1
The physical path termination point carrying TDM data to be cross-connected to the second physical path termination point. The hneTdmCrossConnectPathTerminationPoint1 has a lower ifIndex then the hneTdmCrossConnectPathTerminationPoint2.
OBJECT-TYPE    
  InterfaceIndex  

hneTdmCrossConnectPathTerminationPoint2 1.3.6.1.4.1.2158.3.1.1.1.3.1.1.2
The second physical path termination point carrying TDM data to be cross- connected to the first physical path termination point. The hneTdmCrossConnectPathTerminationPoint2 has a higher ifIndex then the hneTdmCrossConnectPathTerminationPoint1.
OBJECT-TYPE    
  InterfaceIndex  

hneTdmCrossConnectOperStatus 1.3.6.1.4.1.2158.3.1.1.1.3.1.1.3
This attribute indicates the operational state of the TDM cross connection.
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

hneTdmCrossConnectRowStatus 1.3.6.1.4.1.2158.3.1.1.1.3.1.1.4
The status of this entry in the hneTdmCrossConnectTable. This object is used to create or delete a hneTdmCrossConnectTable entry. This object must be set to 'createAndGo' to create a new entry in this table. Row status values: active(1) - set by the agent after this entry is created notInService(2) - not applicable notReady(3) - not applicable createAndGo(4) - set by management entity when creating entry createAndWait(5)- not applicable destroy(6) - set by the management entity to destroy entry
OBJECT-TYPE    
  RowStatus  

hneAtm 1.3.6.1.4.1.2158.3.1.1.1.4
OBJECT IDENTIFIER    

hneAtmInterfaceConfTable 1.3.6.1.4.1.2158.3.1.1.1.4.1
The HNE ATM interface configuration table. This table augments the atmInterfaceConfEntry defined in the ATM MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    HneAtmInterfaceConfEntry

hneAtmInterfaceConfEntry 1.3.6.1.4.1.2158.3.1.1.1.4.1.1
An entry in the HNE ATM interface configuration table. An entry contains HNE specific ATM interface information not found in the ATM MIB.
OBJECT-TYPE    
  HneAtmInterfaceConfEntry  

hneAtmInterfaceValueAddedModeEnabled 1.3.6.1.4.1.2158.3.1.1.1.4.1.1.2
An indication of whether or not value added mode is enabled at the ATM interface. If enabled, received or transmitted cells are routed to the data processor before being forwarded by a Line Interface Unit. true(1) - value added mode is enabled false(2) - value added mode is disabled
OBJECT-TYPE    
  TruthValue  

hneAtmTrafficDescrParamIndexNext 1.3.6.1.4.1.2158.3.1.1.1.4.3
The value to be used when creating an atmTrafficDescrParaEntry. To obtain the index value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index (or -1). A value of -1 indicates that all available entries are assigned.
OBJECT-TYPE    
  AtmTrafficDescrParamIndex  

hneAtmVplTable 1.3.6.1.4.1.2158.3.1.1.1.4.4
The HNE Virtual Path Link (VPL) table. This table augments the atmVplTable defined in the ATM-MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    HneAtmVplEntry

hneAtmVplEntry 1.3.6.1.4.1.2158.3.1.1.1.4.4.1
An entry in the HNE ATM Virtual Path Link Table. This table contains information specific to the HNE implementation.
OBJECT-TYPE    
  HneAtmVplEntry  

hneAtmVplVamMode 1.3.6.1.4.1.2158.3.1.1.1.4.4.1.1
The operational mode of a Value Added Mode VPL that is terminated at a virtual proprietary interface on a Data Processor. The operational modes are: none(0) - Normal loopback mode hostTerminated(1) - Cells received at the Virtual Path Link termination point are routed to the Data Processor in addition to being looped back.
OBJECT-TYPE    
  INTEGER none(0), hostTerminated(1)  

hneAtmfM4 1.3.6.1.4.1.2158.3.1.1.1.5
OBJECT IDENTIFIER    

hneAtmfM4TcAdaptorTable 1.3.6.1.4.1.2158.3.1.1.1.5.1
The HNE sonet path table. This table augments the atmfM4TcAdapterTable defined in the ATM-FORUM-M4-MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    HneAtmfM4TcAdaptorEntry

hneAtmfM4TcAdaptorEntry 1.3.6.1.4.1.2158.3.1.1.1.5.1.1
An entry in the HNE TC adapter table. An entry contains HNE specific TC adapter information.
OBJECT-TYPE    
  HneAtmfM4TcAdaptorEntry  

hneAtmfM4TcHecErroredCellAction 1.3.6.1.4.1.2158.3.1.1.1.5.1.1.1
The action to take when HEC errored cells are detected: pass(1) - forward cells containing HEC errors drop(2) - drop cells containing HEC errors
OBJECT-TYPE    
  INTEGER pass(1), drop(2)  

hnePlugInUnit 1.3.6.1.4.1.2158.3.1.1.1.6
OBJECT IDENTIFIER    

hneMIBTraps 1.3.6.1.4.1.2158.3.1.1.2
OBJECT IDENTIFIER    

hneMIBCompliance 1.3.6.1.4.1.2158.3.1.1.3
OBJECT IDENTIFIER    

hneGroups 1.3.6.1.4.1.2158.3.1.1.3.1
OBJECT IDENTIFIER    

hneSystemGroup 1.3.6.1.4.1.2158.3.1.1.3.1.1
Additional HNE specific objects to the mib-2 system group.
OBJECT-GROUP    

hneSonetGroup 1.3.6.1.4.1.2158.3.1.1.3.1.2
Additional HNE specific objects to the SONET-MIB.
OBJECT-GROUP    

hneTdmGroup 1.3.6.1.4.1.2158.3.1.1.3.1.3
HNE TDM objects.
OBJECT-GROUP    

hneAtmGroup 1.3.6.1.4.1.2158.3.1.1.3.1.4
Additional HNE specific objects to the ATM-MIB.
OBJECT-GROUP    

hneAtmfM4Group 1.3.6.1.4.1.2158.3.1.1.3.1.5
Additional HNE specific objects to the ATM-FORUM-M4-MIB.
OBJECT-GROUP    

hneCompliances 1.3.6.1.4.1.2158.3.1.1.3.2
OBJECT IDENTIFIER    

hneCompliance 1.3.6.1.4.1.2158.3.1.1.3.2.1
The basic implementation requirements for the HNE MIB.
MODULE-COMPLIANCE    

hneMIBStats 1.3.6.1.4.1.2158.3.1.1.4
OBJECT IDENTIFIER    

hneSonetPathCurrentTable 1.3.6.1.4.1.2158.3.1.1.4.5
The HNE SONET/SDH Path Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneSonetPathCurrentEntry

hneSonetPathCurrentEntry 1.3.6.1.4.1.2158.3.1.1.4.5.1
An entry in the HNE sonet path current table. An entry contains HNE specific sonet path information not found in the SONET / SDH MIB.
OBJECT-TYPE    
  HneSonetPathCurrentEntry  

hneSonetPathCurrentRxPosPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.5.1.1
The counter associated with the number of positive pointer justification events that occurred on the receive side of a SONET/SDH path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneSonetPathCurrentRxNegPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.5.1.2
The counter associated with the number of negative pointer justification events that occurred on the receive side of a SONET/SDH path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneSonetPathCurrentTxPosPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.5.1.3
The counter associated with the number of positive pointer justification events that occurred on the transmit side of a SONET/SDH path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneSonetPathCurrentTxNegPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.5.1.4
The counter associated with the number of negative pointer justification events that occurred on the transmit side of a SONET/SDH path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneSonetPathIntervalTable 1.3.6.1.4.1.2158.3.1.1.4.6
The HNE SONET/SDH Path Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneSonetPathIntervalEntry

hneSonetPathIntervalEntry 1.3.6.1.4.1.2158.3.1.1.4.6.1
An entry in the HNE sonet path interval table. An entry contains HNE specific sonet path information not found in the SONET / SDH MIB.
OBJECT-TYPE    
  HneSonetPathIntervalEntry  

hneSonetPathIntervalRxPosPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.6.1.1
The counter associated with the number of positive pointer justification events that occurred on the receive side of a SONET/SDH path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneSonetPathIntervalRxNegPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.6.1.2
The counter associated with the number of negative pointer justification events that occurred on the receive side of a SONET/SDH path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneSonetPathIntervalTxPosPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.6.1.3
The counter associated with the number of positive pointer justification events that occurred on the transmit side of a SONET/SDH path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneSonetPathIntervalTxNegPointerJustCount 1.3.6.1.4.1.2158.3.1.1.4.6.1.4
The counter associated with the number of negative pointer justification events that occurred on the transmit side of a SONET/SDH path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentTable 1.3.6.1.4.1.2158.3.1.1.4.7
The HNE ATM Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneAtmLiuCurrentEntry

hneAtmLiuCurrentEntry 1.3.6.1.4.1.2158.3.1.1.4.7.1
An entry in the HNE line interface unit current entry table. An entry contains atm statistics for an entire line interface unit
OBJECT-TYPE    
  HneAtmLiuCurrentEntry  

hneAtmLiuCurrentPhysLayerCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.1
The counter associated with the number of physical layer cells encountered on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentRxCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.2
The counter associated with the number of cells received on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Counter64  

hneAtmLiuCurrentTxCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.3
The counter associated with the number of cells transmitted on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentCongestionDroppedCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.4
The counter associated with the number of cells dropped due to congestion on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentInvalidCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.5
The counter associated with the number of invalid cells encountered on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentErroredOAMCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.6
The counter associated with the number of errored OAM cells encountered on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentValidOAMCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.7
The counter associated with the number of valid OAM cells encountered on all atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentTxOverrunCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.8
The counter associated with the number of times the output queue of the atm interfaces on a line interface unit was overrun in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentMissingHeaderCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.9
The counter associated with the number of times a physical cell is found missing an internal header in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentNonRoutableCellCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.10
The counter associated with the number of non routable cells encountered on all of the atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentVcSearchFailedCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.11
The counter associated with the number of virtual ciruit search failures encountered on all of the atm interfaces on a line interface unit in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuCurrentInternalParityErrorCount 1.3.6.1.4.1.2158.3.1.1.4.7.1.12
The counter associated with the number of internal parity errors encountered in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryTable 1.3.6.1.4.1.2158.3.1.1.4.8
The HNE ATM Line Interface Unit History table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneAtmLiuHistoryEntry

hneAtmLiuHistoryEntry 1.3.6.1.4.1.2158.3.1.1.4.8.1
An entry in the HNE line interface unit history entry table. An entry contains ATM statistics associated with a sonet line.
OBJECT-TYPE    
  HneAtmLiuHistoryEntry  

hneAtmLiuHistoryPhysLayerCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.1
The counter associated with the number of physical layer cells encountered on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryRxCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.2
The counter associated with the number of cells received on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter64  

hneAtmLiuHistoryTxCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.3
The counter associated with the number of cells transmitted on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryCongestionDroppedCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.4
The counter associated with the number of cells dropped due to congestion on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryInvalidCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.5
The counter associated with the number of invalid cells encountered on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryErroredOAMCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.6
The counter associated with the number of errored OAM cells encountered on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryValidOAMCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.7
The counter associated with the number of valid OAM cells encountered on all ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryTxOverrunCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.8
The counter associated with the number of times the output queue of the ATM interfaces on a line interface unit was overrun in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryMissingHeaderCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.9
The counter associated with the number of times a physical cell is found missing an internal header in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryNonRoutableCellCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.10
The counter associated with the number of non routable cells encountered on all of the ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryVcSearchFailedCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.11
The counter associated with the number of virtual ciruit search failures encountered on all of the ATM interfaces on a line interface unit in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneAtmLiuHistoryInternalParityErrorCount 1.3.6.1.4.1.2158.3.1.1.4.8.1.12
The counter associated with the number of internal parity errors encountered in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentTable 1.3.6.1.4.1.2158.3.1.1.4.9
The HNE ATM Virtual Channel Link Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneVclCurrentEntry

hneVclCurrentEntry 1.3.6.1.4.1.2158.3.1.1.4.9.1
An entry in the HNE vitual channel link current entry table. An entry contains virtual channel statistics.
OBJECT-TYPE    
  HneVclCurrentEntry  

hneVclCurrentBIP16Count 1.3.6.1.4.1.2158.3.1.1.4.9.1.5
The counter associated with the number of virtual channel cells with a Bit Interleave Parity (BIP) error in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentRxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.6
The counter associated with the number of Severely Errored Cell Blocks (SECB) received within virtual channel cells in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentRxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.7
The counter associated with the number of received cells lost within an ingress virtual channel in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentRxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.8
The counter associated with the number of received cells misinserted in an igress virtual channel in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentRxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.9
The counter associated with the number of Bit Interleave Parity Violations (BIPV) received in virtual channel in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentTxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.10
The counter associated with the number of Severely Errored Cell Blocks (SECB) virtual channel cells transmitted in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentTxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.11
The counter associated with the number of transmitted cells lost within an eggress virtual channel in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentTxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.12
The counter associated with the number of transmitted cells misinserted within a eggress virtual channel in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclCurrentTxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.9.1.13
The counter associated with the number of Bit Interleave Parity Violations (BIPV) virtual channel cells transmitted in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryTable 1.3.6.1.4.1.2158.3.1.1.4.10
The HNE ATM Virtual Channel Link History table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneVclHistoryEntry

hneVclHistoryEntry 1.3.6.1.4.1.2158.3.1.1.4.10.1
An entry in the HNE vitual channel link history entry table. An entry contains virtual channel link statistics.
OBJECT-TYPE    
  HneVclHistoryEntry  

hneVclHistoryBIP16Count 1.3.6.1.4.1.2158.3.1.1.4.10.1.5
The counter associated with the number of virtual channel cells with a Bit Interleave Parity (BIP) error in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryRxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.6
The counter associated with the number of Severely Errored Cell Blocks (SECB) received within virtual channel cells in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryRxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.7
The counter associated with the number of received cells lost within an ingress virtual channel in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryRxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.8
The counter associated with the number of received cells misinserted within an igress virtual channel in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryRxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.9
The counter associated with the number of Bit Interleave Parity Violations (BIPV) received in virtual channel in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryTxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.10
The counter associated with the number of Severely Errored Cell Blocks (SECB) virtual channel cells transmitted in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryTxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.11
The counter associated with the number of transmitted cells lost within an eggress virtual channel in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryTxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.12
The counter associated with the number of transmitted cells misinserted within a eggress virtual channel in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVclHistoryTxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.10.1.13
The counter associated with the number of Bit Interleave Parity Violations (BIPV) virtual channel cells transmitted in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentTable 1.3.6.1.4.1.2158.3.1.1.4.11
The HNE ATM Virtual Path Link Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneVplCurrentEntry

hneVplCurrentEntry 1.3.6.1.4.1.2158.3.1.1.4.11.1
An entry in the HNE vitual path link current entry table. An entry contains virtual path statistics.
OBJECT-TYPE    
  HneVplCurrentEntry  

hneVplCurrentBIP16Count 1.3.6.1.4.1.2158.3.1.1.4.11.1.5
The counter associated with the number of virtual path cells with a Bit Interleave Parity error (BIP) in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentRxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.6
The counter associated with the number of Severely Errored Cell Blocks (SECB) received within virtual path cells in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentRxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.7
The counter associated with the number of received cells lost within an ingress virtual path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentRxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.8
The counter associated with the number of received cells misinserted within an igress virtual path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentRxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.9
The counter associated with the number of Bit Interleave Parity Violations (BIPV) received in virtual path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentTxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.10
The counter associated with the number of Severely Errored Cell Blocks (SECB) virtual path cells transmitted in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentTxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.11
The counter associated with the number of transmitted cells lost within an eggress virtual path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentTxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.12
The counter associated with the number of transmitted cells misinserted within a eggress virtual path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplCurrentTxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.11.1.13
The counter associated with the number of Bit Interleave Parity Violations (BIPV) virtual path cells transmitted in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryTable 1.3.6.1.4.1.2158.3.1.1.4.12
The HNE ATM Virtual Path Link History table.
OBJECT-TYPE    
  SEQUENCE OF  
    HneVplHistoryEntry

hneVplHistoryEntry 1.3.6.1.4.1.2158.3.1.1.4.12.1
An entry in the HNE vitual path link history entry table. An entry contains virtual path statistics.
OBJECT-TYPE    
  HneVplHistoryEntry  

hneVplHistoryBIP16Count 1.3.6.1.4.1.2158.3.1.1.4.12.1.5
The counter associated with the number of virtual path cells with a Bit Interleave Parity error (BIP) in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryRxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.6
The counter associated with the number of Severely Errored Cell Blocks (SECB) received within virtual path cells in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryRxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.7
The counter associated with the number of received cells lost within an ingress virtual path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryRxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.8
The counter associated with the number of received cells misinserted within an igress virtual path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryRxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.9
The counter associated with the number of Bit Interleave Parity Violations (BIPV) received in virtual path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryTxSECBCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.10
The counter associated with the number of Severely Errored Cell Blocks (SECB) virtual path cells transmitted in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryTxLostCellCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.11
The counter associated with the number of transmitted cells lost within an eggress virtual path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryTxMisinsertedCellCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.12
The counter associated with the number of transmitted cells misinserted within a eggress virtual path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

hneVplHistoryTxBIPVCount 1.3.6.1.4.1.2158.3.1.1.4.12.1.13
The counter associated with the number of Bit Interleave Parity Violations (BIPV) virtual path cells transmitted in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge32  

Defined Objects

HnePlugInUnitType  
HNE hardware plug-in unit types: unknown(0) - Unknown plug-in unit type mpu(1) - Management Processor Unit dpu(2) - Data Processor Unit smu(3) - Sync Module Unit liu(4) - Line Interface Unit hsf(5) - Hybrid Switch Fabric Unit powerSupply(6) - Power supply fan(7) - Fan Unit hardDrive(8) - Hard drive
TEXTUAL-CONVENTION    
  INTEGER unknown(0), mpu(1), dpu(2), smu(3), liu(4), hsf(5), powerSupply(6), fan(7), hardDrive(8)  

HneSonetLineEntry  
SEQUENCE    
  INTEGER as hneSonetLineTimingSource  
  INTEGER as hneSonetLineDccSelection  
  TruthValue as hneSonetLineOverheadLoopThroughModeEnabled  

HneSonetProtectionEntry  
SEQUENCE    
  InterfaceIndex as hneSonetProtectionInterfaceHigh  
  InterfaceIndex as hneSonetProtectionInterfaceLow  
  InterfaceIndex as hneSonetProtectionInterfaceWorking  
  INTEGER as hneSonetProtectionConfig  
  TruthValue as hneSonetProtectionRevertive  
  TruthValue as hneSonetProtectionBiDirectional  

HneSonetPathEntry  
SEQUENCE    
  INTEGER as hneSonetPathContentType  
  TruthValue as hneSonetPathOverheadLoopThroughModeEnabled  
  INTEGER as hneSonetPathSpeMicMode  
  DisplayString as hneSonetPathReceiveTraceMessage  
  DisplayString as hneSonetPathTransmitTraceMessage  
  RowStatus as hneSonetPathRowStatus  

HneTdmCrossConnectEntry  
SEQUENCE    
  InterfaceIndex as hneTdmCrossConnectPathTerminationPoint1  
  InterfaceIndex as hneTdmCrossConnectPathTerminationPoint2  
  INTEGER as hneTdmCrossConnectOperStatus  
  RowStatus as hneTdmCrossConnectRowStatus  

HneAtmInterfaceConfEntry  
SEQUENCE    
  TruthValue as hneAtmInterfaceValueAddedModeEnabled  

HneAtmVplEntry  
SEQUENCE    
  INTEGER as hneAtmVplVamMode  

HneAtmfM4TcAdaptorEntry  
SEQUENCE    
  INTEGER as hneAtmfM4TcHecErroredCellAction  

HneSonetPathCurrentEntry  
SEQUENCE    
  Gauge32 as hneSonetPathCurrentRxPosPointerJustCount  
  Gauge32 as hneSonetPathCurrentRxNegPointerJustCount  
  Gauge32 as hneSonetPathCurrentTxPosPointerJustCount  
  Gauge32 as hneSonetPathCurrentTxNegPointerJustCount  

HneSonetPathIntervalEntry  
SEQUENCE    
  Gauge32 as hneSonetPathIntervalRxPosPointerJustCount  
  Gauge32 as hneSonetPathIntervalRxNegPointerJustCount  
  Gauge32 as hneSonetPathIntervalTxPosPointerJustCount  
  Gauge32 as hneSonetPathIntervalTxNegPointerJustCount  

HneAtmLiuCurrentEntry  
SEQUENCE    
  Gauge32 as hneAtmLiuCurrentPhysLayerCellCount  
  Counter64 as hneAtmLiuCurrentRxCellCount  
  Gauge32 as hneAtmLiuCurrentTxCellCount  
  Gauge32 as hneAtmLiuCurrentCongestionDroppedCount  
  Gauge32 as hneAtmLiuCurrentInvalidCellCount  
  Gauge32 as hneAtmLiuCurrentErroredOAMCellCount  
  Gauge32 as hneAtmLiuCurrentValidOAMCellCount  
  Gauge32 as hneAtmLiuCurrentTxOverrunCount  
  Gauge32 as hneAtmLiuCurrentMissingHeaderCellCount  
  Gauge32 as hneAtmLiuCurrentNonRoutableCellCount  
  Gauge32 as hneAtmLiuCurrentVcSearchFailedCount  
  Gauge32 as hneAtmLiuCurrentInternalParityErrorCount  

HneAtmLiuHistoryEntry  
SEQUENCE    
  Gauge32 as hneAtmLiuHistoryPhysLayerCellCount  
  Counter64 as hneAtmLiuHistoryRxCellCount  
  Gauge32 as hneAtmLiuHistoryTxCellCount  
  Gauge32 as hneAtmLiuHistoryCongestionDroppedCount  
  Gauge32 as hneAtmLiuHistoryInvalidCellCount  
  Gauge32 as hneAtmLiuHistoryErroredOAMCellCount  
  Gauge32 as hneAtmLiuHistoryValidOAMCellCount  
  Gauge32 as hneAtmLiuHistoryTxOverrunCount  
  Gauge32 as hneAtmLiuHistoryMissingHeaderCellCount  
  Gauge32 as hneAtmLiuHistoryNonRoutableCellCount  
  Gauge32 as hneAtmLiuHistoryVcSearchFailedCount  
  Gauge32 as hneAtmLiuHistoryInternalParityErrorCount  

HneVclCurrentEntry  
SEQUENCE    
  Gauge32 as hneVclCurrentBIP16Count  
  Gauge32 as hneVclCurrentRxSECBCount  
  Gauge32 as hneVclCurrentRxLostCellCount  
  Gauge32 as hneVclCurrentRxMisinsertedCellCount  
  Gauge32 as hneVclCurrentRxBIPVCount  
  Gauge32 as hneVclCurrentTxSECBCount  
  Gauge32 as hneVclCurrentTxLostCellCount  
  Gauge32 as hneVclCurrentTxMisinsertedCellCount  
  Gauge32 as hneVclCurrentTxBIPVCount  

HneVclHistoryEntry  
SEQUENCE    
  Gauge32 as hneVclHistoryBIP16Count  
  Gauge32 as hneVclHistoryRxSECBCount  
  Gauge32 as hneVclHistoryRxLostCellCount  
  Gauge32 as hneVclHistoryRxMisinsertedCellCount  
  Gauge32 as hneVclHistoryRxBIPVCount  
  Gauge32 as hneVclHistoryTxSECBCount  
  Gauge32 as hneVclHistoryTxLostCellCount  
  Gauge32 as hneVclHistoryTxMisinsertedCellCount  
  Gauge32 as hneVclHistoryTxBIPVCount  

HneVplCurrentEntry  
SEQUENCE    
  Gauge32 as hneVplCurrentBIP16Count  
  Gauge32 as hneVplCurrentRxSECBCount  
  Gauge32 as hneVplCurrentRxLostCellCount  
  Gauge32 as hneVplCurrentRxMisinsertedCellCount  
  Gauge32 as hneVplCurrentRxBIPVCount  
  Gauge32 as hneVplCurrentTxSECBCount  
  Gauge32 as hneVplCurrentTxLostCellCount  
  Gauge32 as hneVplCurrentTxMisinsertedCellCount  
  Gauge32 as hneVplCurrentTxBIPVCount  

HneVplHistoryEntry  
SEQUENCE    
  Gauge32 as hneVplHistoryBIP16Count  
  Gauge32 as hneVplHistoryRxSECBCount  
  Gauge32 as hneVplHistoryRxLostCellCount  
  Gauge32 as hneVplHistoryRxMisinsertedCellCount  
  Gauge32 as hneVplHistoryRxBIPVCount  
  Gauge32 as hneVplHistoryTxSECBCount  
  Gauge32 as hneVplHistoryTxLostCellCount  
  Gauge32 as hneVplHistoryTxMisinsertedCellCount  
  Gauge32 as hneVplHistoryTxBIPVCount