SNA-SDLC-MIB

File: SNA-SDLC-MIB.mib (139703 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Counter32 Integer32 TimeTicks
DisplayString RowStatus TimeInterval
MODULE-COMPLIANCE OBJECT-GROUP mib-2
ifIndex ifAdminStatus ifOperStatus

Defined Objects

snaDLC 1.3.6.1.2.1.41
This is the MIB module for objects used to manage SDLC devices.
MODULE-IDENTITY    

sdlc 1.3.6.1.2.1.41.1
OBJECT IDENTIFIER    

sdlcPortGroup 1.3.6.1.2.1.41.1.1
OBJECT IDENTIFIER    

sdlcPortAdminTable 1.3.6.1.2.1.41.1.1.1
This table contains objects that can be changed to manage an SDLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the sdlcPortOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was changed after the interface was started.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcPortAdminEntry

sdlcPortAdminEntry 1.3.6.1.2.1.41.1.1.1.1
A list of configured values for an SDLC port.
OBJECT-TYPE    
  SdlcPortAdminEntry  

sdlcPortAdminName 1.3.6.1.2.1.41.1.1.1.1.1
An octet string that defines the physical port to which this interface is assigned. It has implementation-specific significance. Its value shall be unique within the administered system. It must contain only ASCII printable characters. Should an implementation choose to accept a write operation for this object, it causes the logical port definition associated with the table instance to be moved to a different physical port. A write operation shall not take effect until the port is cycled inactive.
OBJECT-TYPE    
  DisplayString SIZE(1..10)  

sdlcPortAdminRole 1.3.6.1.2.1.41.1.1.1.1.2
This object describes the role that the link station shall assume the next time a connection is established. Even though this is defined as a port object, it is a link station attribute in the sense that a role is per link station. However, it is not possible to vary link station roles on a particular port. For example, if an SDLC port is configured to primary, all link stations on that port must be primary.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), negotiable(3)  

sdlcPortAdminType 1.3.6.1.2.1.41.1.1.1.1.3
This parameter defines whether the SDLC port is to connect to a leased or switched line. A write operation to this administrative value shall not take effect until the SDLC port has been cycled inactive.
OBJECT-TYPE    
  INTEGER leased(1), switched(2)  

sdlcPortAdminTopology 1.3.6.1.2.1.41.1.1.1.1.4
This parameter defines whether the SDLC port is capable of operating in either a point-to-point or multipoint topology. sdlcPortAdminTopology == multipoint implies the port can also operate in a point-to-point topology. sdlcPortAdminTopology == pointToPoint does not imply the port can operate in a multipoint topology. A write operation to this administrative value shall not take effect until the SDLC port has been cycled inactive.
OBJECT-TYPE    
  INTEGER pointToPoint(1), multipoint(2)  

sdlcPortAdminISTATUS 1.3.6.1.2.1.41.1.1.1.1.5
This parameter controls the initial value of the administrative status, ifAdminStatus, of this SDLC port at port start-up. Depending on the implementation, a write operation to this administrative object may not take effect until the SDLC port has been cycled inactive.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

sdlcPortAdminACTIVTO 1.3.6.1.2.1.41.1.1.1.1.6
This parameter defines the period of time (in 1/100ths of a second) that the port will allow a switched line to remain inactive before disconnecting. A switched line is considered to be inactive if there are no I-Frames being transferred. A value of zero indicates no timeout. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminType == switched The object descriptor contains the name of an NCP configuration parameter, ACTIVTO. Please note that the value of this object represents 1/100ths of a second while the NCP ACTIVTO is represented in seconds.
OBJECT-TYPE    
  TimeInterval  

sdlcPortAdminPAUSE 1.3.6.1.2.1.41.1.1.1.1.7
This object defines the minimum elapsed time (in 1/100ths of a second) between any two traversals of the poll list for a primary SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. The object descriptor contains the name of an NCP configuration parameter, PAUSE. Please note that the value of this object represents 1/100ths of a second while the NCP PAUSE is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary
OBJECT-TYPE    
  TimeInterval  

sdlcPortAdminSERVLIM 1.3.6.1.2.1.41.1.1.1.1.8
This object defines the number of times the active poll list will be traversed before polling a station on the slow poll list for a primary, multipoint SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary and sdlcPortAdminTopology == multipoint
OBJECT-TYPE    
  Integer32  

sdlcPortAdminSlowPollTimer 1.3.6.1.2.1.41.1.1.1.1.9
This object describes the elapsed time (in 1/100ths of a second) between polls for failed secondary link station addresses. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary and sdlcPortAdminTopology == multipoint
OBJECT-TYPE    
  TimeInterval  

sdlcPortOperTable 1.3.6.1.2.1.41.1.1.2
This table contains current SDLC port parameters. Many of these objects have corresponding objects in the sdlcPortAdminTable.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcPortOperEntry

sdlcPortOperEntry 1.3.6.1.2.1.41.1.1.2.1
Currently set parameters for a specific SDLC port.
OBJECT-TYPE    
  SdlcPortOperEntry  

sdlcPortOperName 1.3.6.1.2.1.41.1.1.2.1.1
An octet string that describes the physical port to which this interface is currently attached. It has implementation-specific significance.
OBJECT-TYPE    
  DisplayString SIZE(1..8)  

sdlcPortOperRole 1.3.6.1.2.1.41.1.1.2.1.2
This object describes the role that the link station has assumed on this connection. Even though this is defined as a port object, it is a link station attribute in the sense that a role is per link station. However, it is not possible to vary link station roles on a particular port. For example, if an SDLC port is configured to primary, all link stations on that port must be primary. The value of sdlcPortOperRole is undefined(3) whenever the link station role has not yet been established by the mode setting command.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), undefined(3)  

sdlcPortOperType 1.3.6.1.2.1.41.1.1.2.1.3
This parameter defines whether the SDLC port is currently operating as though connected to a leased or switched line.
OBJECT-TYPE    
  INTEGER leased(1), switched(2)  

sdlcPortOperTopology 1.3.6.1.2.1.41.1.1.2.1.4
This parameter defines whether the SDLC port is currently operating in a point-to-point or multipoint topology.
OBJECT-TYPE    
  INTEGER pointToPoint(1), multipoint(2)  

sdlcPortOperISTATUS 1.3.6.1.2.1.41.1.1.2.1.5
This parameter describes the initial value of the administrative status, ifAdminStatus, of this SDLC port at last port start-up.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

sdlcPortOperACTIVTO 1.3.6.1.2.1.41.1.1.2.1.6
This parameter defines the period of time (in 100ths of a second) that the port will allow a switched line to remain inactive before disconnecting. A switched line is considered to be inactive if there are no I-Frames being transferred. The object descriptor contains the name of an NCP configuration parameter, ACTIVTO. Please note that the value of this object represents 1/100ths of a second while the NCP ACTIVTO is represented in seconds. A value of zero indicates no timeout.
OBJECT-TYPE    
  TimeInterval  

sdlcPortOperPAUSE 1.3.6.1.2.1.41.1.1.2.1.7
This object describes the current minimum elapsed time (in 1/100ths of a second) between any two traversals of the poll list for a primary SDLC port. The object descriptor contains the name of an NCP configuration parameter, PAUSE. Please note that the value of this object represents 1/100ths of a second while the NCP PAUSE is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary
OBJECT-TYPE    
  TimeInterval  

sdlcPortOperSlowPollMethod 1.3.6.1.2.1.41.1.1.2.1.8
This object defines the exact method that is in effect for periodically polling failed secondary link station addresses. If sdlcPortOperSlowPollMethod == servlim, then sdlcPortOperSERVLIM defines the actual polling characteristics. If sdlcPortOperSlowPollMethod == pollpause, then sdlcPortOperSlowPollTimer defines the actual polling characteristics. If sdlcPortOperSlowPollMethod == other, then the polling characteristics are modeled in vendor-specific objects. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint
OBJECT-TYPE    
  INTEGER servlim(1), pollpause(2), other(3)  

sdlcPortOperSERVLIM 1.3.6.1.2.1.41.1.1.2.1.9
This object describes the number of times the active poll list is currently being traversed before polling a station on the slow poll list for a primary, multipoint SDLC port. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint
OBJECT-TYPE    
  Integer32  

sdlcPortOperSlowPollTimer 1.3.6.1.2.1.41.1.1.2.1.10
This object describes the elapsed time (in 1/100ths of a second) between polls for failed secondary link station addresses. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint
OBJECT-TYPE    
  TimeInterval  

sdlcPortOperLastModifyTime 1.3.6.1.2.1.41.1.1.2.1.11
This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero.
OBJECT-TYPE    
  TimeTicks  

sdlcPortOperLastFailTime 1.3.6.1.2.1.41.1.1.2.1.12
This object describes the value of sysUpTime when this SDLC port last failed. If the port has not failed, then this value shall be zero.
OBJECT-TYPE    
  TimeTicks  

sdlcPortOperLastFailCause 1.3.6.1.2.1.41.1.1.2.1.13
This enumerated object describes the cause of the last failure of this SDLC port. If the port has not failed, then this object has a value of undefined(1).
OBJECT-TYPE    
  INTEGER undefined(1), physical(2)  

sdlcPortStatsTable 1.3.6.1.2.1.41.1.1.3
Each entry in this table contains statistics for a specific SDLC port.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcPortStatsEntry

sdlcPortStatsEntry 1.3.6.1.2.1.41.1.1.3.1
A list of statistics for an SDLC port.
OBJECT-TYPE    
  SdlcPortStatsEntry  

sdlcPortStatsPhysicalFailures 1.3.6.1.2.1.41.1.1.3.1.1
This object reflects the total number of times this port has failed due to its physical media since port startup. At port startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsInvalidAddresses 1.3.6.1.2.1.41.1.1.3.1.2
This object reflects the total number of frames received by this port with invalid link station addresses.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsDwarfFrames 1.3.6.1.2.1.41.1.1.3.1.3
This object reflects the total number of frames received by this port which were delivered intact by the physical layer but were too short to be legal. Ignoring the frame check sequence (FCS), a frame is considered to be too short if it is less than 2 bytes for sdlcLSOperMODULO of eight, or if it is less than 3 bytes for sdlcLSOperMODULO of onetwentyeight.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsPollsIn 1.3.6.1.2.1.41.1.1.3.1.4
This object reflects the total number of polls received by this port since the port was created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsPollsOut 1.3.6.1.2.1.41.1.1.3.1.5
This object reflects the total number of polls sent by this port since the port was created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsPollRspsIn 1.3.6.1.2.1.41.1.1.3.1.6
This object reflects the total number of poll responses received by this port since the port was created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsPollRspsOut 1.3.6.1.2.1.41.1.1.3.1.7
This object reflects the total number of poll responses sent by this port since the port was created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsLocalBusies 1.3.6.1.2.1.41.1.1.3.1.8
This object reflects the total number of times that the local SDLC link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsRemoteBusies 1.3.6.1.2.1.41.1.1.3.1.9
This object reflects the total number of times that the adjacent (i.e., remote) SDLC link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsIFramesIn 1.3.6.1.2.1.41.1.1.3.1.10
This object reflects the total number of I-Frames that have been received by SDLC link stations on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsIFramesOut 1.3.6.1.2.1.41.1.1.3.1.11
This object reflects the total number of I-Frames that have been transmitted by SDLC link stations on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsOctetsIn 1.3.6.1.2.1.41.1.1.3.1.12
This object reflects the total octets received from adjacent SDLC link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsOctetsOut 1.3.6.1.2.1.41.1.1.3.1.13
This object reflects the total octets transmitted to adjacent SDLC link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsProtocolErrs 1.3.6.1.2.1.41.1.1.3.1.14
This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of having received a protocol violation from the adjacent link station. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsActivityTOs 1.3.6.1.2.1.41.1.1.3.1.15
This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of no activity on the link. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsRNRLIMITs 1.3.6.1.2.1.41.1.1.3.1.16
This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of its RNRLIMIT timer expiring. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsRetriesExps 1.3.6.1.2.1.41.1.1.3.1.17
This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of a retry sequence being exhausted. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsRetransmitsIn 1.3.6.1.2.1.41.1.1.3.1.18
This object reflects the total number of I-Frames retransmitted by remote link stations for all SDLC link stations on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcPortStatsRetransmitsOut 1.3.6.1.2.1.41.1.1.3.1.19
This object reflects the total number of I-Frames retransmitted by all local SDLC link stations on this port. This object is initialized to zero when the port is created.
OBJECT-TYPE    
  Counter32  

sdlcLSGroup 1.3.6.1.2.1.41.1.2
OBJECT IDENTIFIER    

sdlcLSAdminTable 1.3.6.1.2.1.41.1.2.1
This table contains objects that can be changed to manage an SDLC link station. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in sdlcLSAdminTable can be created either by an agent or a management station. The management station can create an entry in sdlcLSAdminTable by setting the appropriate value in sdlcLSAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the sdlcLSOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcLSAdminEntry

sdlcLSAdminEntry 1.3.6.1.2.1.41.1.2.1.1
A list of configured values for an SDLC link station.
OBJECT-TYPE    
  SdlcLSAdminEntry  

sdlcLSAddress 1.3.6.1.2.1.41.1.2.1.1.1
This value is the poll address of the secondary link station for this SDLC link. It uniquely identifies the SDLC link station within a single SDLC port.
OBJECT-TYPE    
  INTEGER 1..255  

sdlcLSAdminName 1.3.6.1.2.1.41.1.2.1.1.2
An octet string that defines the local name of the SDLC link station. This field may be sent in the XID3 control vector 0x0E, type 0xF7.
OBJECT-TYPE    
  DisplayString SIZE(1..10)  

sdlcLSAdminState 1.3.6.1.2.1.41.1.2.1.1.3
This object controls the desired state of the SDLC station. The managed system shall attempt to keep the operational state, sdlcLSOperState, consistent with this value.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

sdlcLSAdminISTATUS 1.3.6.1.2.1.41.1.2.1.1.4
This parameter controls the desired state, sdlcLSAdminState, of the SDLC link station at link station start-up.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

sdlcLSAdminMAXDATASend 1.3.6.1.2.1.41.1.2.1.1.5
This object contains the maximum PDU size that the local link station thinks it can send to the adjacent link station before having received any XID from the ALS. After the maximum PDU size that the ALS can receive is known (via XID exchange) that value is reflected in sdlcLSOperMAXDATASend and takes precedence over this object. This value includes the Transmission Header (TH) and the Request Header (RH).
OBJECT-TYPE    
  Integer32  

sdlcLSAdminMAXDATARcv 1.3.6.1.2.1.41.1.2.1.1.6
This object contains the maximum PDU size that the local link station can receive from the adjacent link station. This value is sent in the XID to the ALS. This value includes the Transmission Header (TH) and the Request Header (RH).
OBJECT-TYPE    
  Integer32  

sdlcLSAdminREPLYTO 1.3.6.1.2.1.41.1.2.1.1.7
This object controls the reply timeout (in 1/100ths of a second) for an SDLC link station. If the link station does not receive a response to a poll or message before the specified time expires then the appropriate error recovery shall be initiated. The object descriptor contains the name of an NCP configuration parameter, REPLYTO. Please note that the value of this object represents 1/100ths of a second while the NCP REPLYTO is represented in 1/10ths of a second. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperREPLYTO, until the link station is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary
OBJECT-TYPE    
  TimeInterval  

sdlcLSAdminMAXIN 1.3.6.1.2.1.41.1.2.1.1.8
This object controls the maximum number of unacknowledged I-frames which an SDLC link station may receive. This should range from 1 to (sdlcLSAdminMODULO - 1). This value is sent in the XID to the ALS. A write operation to this administered value will not change the operational value, sdlcLSOperMAXIN, until the link station is cycled inactive.
OBJECT-TYPE    
  INTEGER 1..127  

sdlcLSAdminMAXOUT 1.3.6.1.2.1.41.1.2.1.1.9
This object controls the maximum number of consecutive unacknowledged I-frames which an SDLC link station shall send without an acknowledgement. This shall range from 1 to (sdlcLSAdminMODULO - 1). For link stations on switched SDLC lines, certain implementations may choose to override this administered value with the value received in the XID exchange. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperMAXOUT, until the link station is cycled inactive. An implementation can support only modulo 8, only modulo 128, or both.
OBJECT-TYPE    
  INTEGER 1..127  

sdlcLSAdminMODULO 1.3.6.1.2.1.41.1.2.1.1.10
This object controls the modulus for an SDLC link station. This modulus determines the size of the rotating acknowledgement window used the SDLC link station pair. A write operation to this administered value will not change the operational value, sdlcLSOperMODULO, until the link station is cycled inactive. An implementation can support only modulo 8, only modulo 128, or both.
OBJECT-TYPE    
  INTEGER eight(8), onetwentyeight(128)  

sdlcLSAdminRETRIESm 1.3.6.1.2.1.41.1.2.1.1.11
This object controls number of retries in a retry sequence for the local SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The number of times that the retry sequence is to be repeated is controlled by the object: sdlcLSAdminRETRIESn. The interval between retry sequences is controlled by the object: sdlcLSAdminRETRIESt. A value of zero indicates no retries. If the value of sdlcLSAdminRETRIESm is zero, then the values of sdlcLSAdminRETRIESt and sdlcLSAdminRETRIESn should also be zero. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESm, until the link station is cycled inactive.
OBJECT-TYPE    
  INTEGER 0..128  

sdlcLSAdminRETRIESt 1.3.6.1.2.1.41.1.2.1.1.12
This object controls the interval (in 1/100ths of a second) between retry sequences for the local SDLC link station if multiple retry sequences are specified . A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The number of repeated retries sequences is controlled by the object: sdlcLSAdminRETRIESn. The retries per sequence is controlled by the object: sdlcLSAdminRETRIESm. The object descriptor contains the name of an NCP configuration parameter, RETRIESt. Please note that the value of this object represents 1/100ths of a second while the NCP RETRIESt is represented in seconds. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESt, until the link station is cycled inactive.
OBJECT-TYPE    
  TimeInterval  

sdlcLSAdminRETRIESn 1.3.6.1.2.1.41.1.2.1.1.13
This object controls the number of times that a retry sequence is repeated for the local SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The interval between retry sequences is controlled by the object: sdlcLSAdminRETRIESn. The retries per sequence is controlled by the object: sdlcLSAdminRETRIESm. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESn, until the link station is cycled inactive.
OBJECT-TYPE    
  Integer32  

sdlcLSAdminRNRLIMIT 1.3.6.1.2.1.41.1.2.1.1.14
This object controls the length of time (in 1/100ths of a second) that an SDLC link station will allow its adjacent link station to remain in a busy (RNR) state before declaring it inoperative. A value of sdlcLSAdminRNRLIMIT == 0 means there is no limit. The object descriptor contains the name of an NCP configuration parameter, RNRLIMIT. Please note that the value of this object represents 1/100ths of a second while the NCP RNRLIMIT is represented in minutes. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRNRLIMIT, until the link station is cycled inactive.
OBJECT-TYPE    
  TimeInterval  

sdlcLSAdminDATMODE 1.3.6.1.2.1.41.1.2.1.1.15
This object controls whether communications mode with the adjacent link station is two-way-alternate (half) or two-way-simultaneous (full). A write operation to this administered value will not change the operational value, sdlcLSOperDATMODE, until the link station is cycled inactive.
OBJECT-TYPE    
  INTEGER half(1), full(2)  

sdlcLSAdminGPoll 1.3.6.1.2.1.41.1.2.1.1.16
This object describes the group poll address for this link station instance. If group poll is not in effect for this link station instance, the value for sdlcLSAdminGPoll should be zero. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperGPoll, until the link station is cycled inactive.
OBJECT-TYPE    
  INTEGER 0..254  

sdlcLSAdminSimRim 1.3.6.1.2.1.41.1.2.1.1.17
This object controls the support for transmission and receipt of SIM and RIM control frames for this link station. The value of this object controls the setting of the transmit-receive capability sent in the XID field.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdlcLSAdminXmitRcvCap 1.3.6.1.2.1.41.1.2.1.1.18
This object controls the transmit-receive capabilities for this SDLC link station. The value of this object establishes the value of the transmit-receive capability indicator sent in the XID image to the adjacent link station.
OBJECT-TYPE    
  INTEGER twa(1), tws(2)  

sdlcLSAdminRowStatus 1.3.6.1.2.1.41.1.2.1.1.19
This object is used by a management station to create or delete the row entry in sdlcLSAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the sdlcLSOperTable with sdlcLSOperState equal to 'discontacted (1)'.
OBJECT-TYPE    
  RowStatus  

sdlcLSOperTable 1.3.6.1.2.1.41.1.2.2
This table contains current SDLC link parameters. Many of these objects have corresponding objects in the sdlcLSAdminTable.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcLSOperEntry

sdlcLSOperEntry 1.3.6.1.2.1.41.1.2.2.1
A list of status and control values for an SDLC link station.
OBJECT-TYPE    
  SdlcLSOperEntry  

sdlcLSOperName 1.3.6.1.2.1.41.1.2.2.1.1
An octet string that defines the name of the remote SDLC link station. This field is received in the XID3 control vector 0x0E, type 0xF7.
OBJECT-TYPE    
  DisplayString SIZE(1..10)  

sdlcLSOperRole 1.3.6.1.2.1.41.1.2.2.1.2
This object reflects the current role that the link station is assuming. The value of sdlcLSOperRole is undefined(3) whenever the link station role has not yet been established by the mode setting command.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), undefined(3)  

sdlcLSOperState 1.3.6.1.2.1.41.1.2.2.1.3
This object describes the operational state of the SDLC link station. The managed system shall attempt to keep this value consistent with the administered state, sdlcLSAdminState
OBJECT-TYPE    
  INTEGER discontacted(1), contactPending(2), contacted(3), discontactPending(4)  

sdlcLSOperMAXDATASend 1.3.6.1.2.1.41.1.2.2.1.4
This object contains the actual maximum PDU size that the local link station can send to the adjacent link station. This object is established from the value received in the XID from the adjacent link station. If no XID is received, then this value is implementation dependent (for instance, it could be the value of sdlcLSAdminMAXDATASend). This value includes the Transmission Header (TH) and the Request Header (RH).
OBJECT-TYPE    
  Integer32  

sdlcLSOperREPLYTO 1.3.6.1.2.1.41.1.2.2.1.5
This object reflects the current reply timeout (in 1/100ths of a second) for an SDLC link station. If the link station does not receive a response to a poll or message before the specified time expires then the appropriate error recovery shall be initiated. The object descriptor contains the name of an NCP configuration parameter, REPLYTO. Please note that the value of this object represents 1/100ths of a second while the NCP REPLYTO is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortOperRole == primary
OBJECT-TYPE    
  TimeInterval  

sdlcLSOperMAXIN 1.3.6.1.2.1.41.1.2.2.1.6
This object reflects the current maximum number of unacknowledged I-frames which an SDLC link station may receive. This shall range from 1 to (sdlcLSOperMODULO - 1).
OBJECT-TYPE    
  INTEGER 1..127  

sdlcLSOperMAXOUT 1.3.6.1.2.1.41.1.2.2.1.7
This object controls the maximum number of consecutive unacknowledged I-frames which an SDLC link station shall send without an acknowledgement. This shall range from 1 to (sdlcLSAdminMODULO - 1). This value may controlled by the administered MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value received during the XID exchange.
OBJECT-TYPE    
  INTEGER 1..127  

sdlcLSOperMODULO 1.3.6.1.2.1.41.1.2.2.1.8
This object reflects the current modulus for an SDLC link station. This modulus determines the size of rotating acknowledgement window used by the SDLC link station pair.
OBJECT-TYPE    
  INTEGER eight(8), onetwentyeight(128)  

sdlcLSOperRETRIESm 1.3.6.1.2.1.41.1.2.2.1.9
This object controls number of retries in a retry sequence for an SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The current number of times that the retry sequence is to be repeated is reflected by the object: sdlcLSOperRETRIESn. The current interval between retry sequences is reflected by the object: sdlcLSOperRETRIESt.
OBJECT-TYPE    
  INTEGER 0..128  

sdlcLSOperRETRIESt 1.3.6.1.2.1.41.1.2.2.1.10
This object reflects the current interval (in 1/100ths of a second) between retry sequences for an SDLC link station if multiple retry sequences are specified. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The object descriptor contains the name of an NCP configuration parameter, RETRIESt. Please note that the value of this object represents 1/100ths of a second while the NCP RETRIESt is represented in seconds. The current number of repeated retries sequences is reflected by the object: sdlcLSOperRETRIESn. The current retries per sequence is reflected by the object: sdlcLSOperRETRIESm.
OBJECT-TYPE    
  TimeInterval  

sdlcLSOperRETRIESn 1.3.6.1.2.1.41.1.2.2.1.11
This object reflects the current number of times that a retry sequence is repeated for an SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The current interval between retry sequences is reflected by the object: sdlcLSOperRETRIESn. The current retries per sequence is reflected by the object: sdlcLSOperRETRIESm.
OBJECT-TYPE    
  INTEGER 0..127  

sdlcLSOperRNRLIMIT 1.3.6.1.2.1.41.1.2.2.1.12
This object reflects the current length of time (in 1/100ths of a second) that an SDLC link station will allow its adjacent link station to remain in a busy (RNR) state before declaring it inoperative. The object descriptor contains the name of an NCP configuration parameter, RNRLIMIT. Please note that the value of this object represents 1/100ths of a second while the NCP RNRLIMIT is represented in minutes. A value of sdlcLSOperRNRLIMIT == 0 means there is no limit.
OBJECT-TYPE    
  TimeInterval  

sdlcLSOperDATMODE 1.3.6.1.2.1.41.1.2.2.1.13
This object reflects whether the current communications mode with the adjacent link station is two-way-alternate (half) or two-way-simultaneous (full).
OBJECT-TYPE    
  INTEGER half(1), full(2)  

sdlcLSOperLastModifyTime 1.3.6.1.2.1.41.1.2.2.1.14
This object describes the value of sysUpTime when this link station definition was last modified. If the link station has not been modified, then this value shall be zero.
OBJECT-TYPE    
  TimeTicks  

sdlcLSOperLastFailTime 1.3.6.1.2.1.41.1.2.2.1.15
This object describes the value of sysUpTime when this SDLC link station last failed. If the link station has not failed, then this value shall be zero.
OBJECT-TYPE    
  TimeTicks  

sdlcLSOperLastFailCause 1.3.6.1.2.1.41.1.2.2.1.16
This enumerated object reflects the cause of the last failure of this SDLC link station. If the link station has not failed, then this object will have a value of undefined(1).
OBJECT-TYPE    
  INTEGER undefined(1), rxFRMR(2), txFRMR(3), noResponse(4), protocolErr(5), noActivity(6), rnrLimit(7), retriesExpired(8)  

sdlcLSOperLastFailCtrlIn 1.3.6.1.2.1.41.1.2.2.1.17
This object reflects the last control octet or octets (depending on modulus) received by this SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

sdlcLSOperLastFailCtrlOut 1.3.6.1.2.1.41.1.2.2.1.18
This object reflects the last control octet or octets (depending on modulus) sent by this SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

sdlcLSOperLastFailFRMRInfo 1.3.6.1.2.1.41.1.2.2.1.19
This object reflects the information field of the FRMR frame if the last failure for this SDLC link station was as a result of an invalid frame. Otherwise, this field has no meaning.
OBJECT-TYPE    
  OCTET STRING SIZE(3)  

sdlcLSOperLastFailREPLYTOs 1.3.6.1.2.1.41.1.2.2.1.20
This object reflects the number of times that the REPLYTO timer had expired for an SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning.
OBJECT-TYPE    
  Counter32  

sdlcLSOperEcho 1.3.6.1.2.1.41.1.2.2.1.21
This object identifies whether the echo bit is in effect for this particular link station.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdlcLSOperGPoll 1.3.6.1.2.1.41.1.2.2.1.22
This object describes the group poll address in effect for this link station instance.
OBJECT-TYPE    
  INTEGER 0..254  

sdlcLSOperSimRim 1.3.6.1.2.1.41.1.2.2.1.23
This object reflects the support for transmission and receipt of SIM and RIM control frames for the adjacent link station. The value of this object is set from the XID field received from the adjacent link station.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdlcLSOperXmitRcvCap 1.3.6.1.2.1.41.1.2.2.1.24
This object reflects the transmit-receive capabilities for the adjacent SDLC link station. The value of this object is the value of the transmit-receive capability indicator received in the XID image from the adjacent link station.
OBJECT-TYPE    
  INTEGER twa(1), tws(2)  

sdlcLSStatsTable 1.3.6.1.2.1.41.1.2.3
Each entry in this table contains statistics for a specific SDLC link station.
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcLSStatsEntry

sdlcLSStatsEntry 1.3.6.1.2.1.41.1.2.3.1
A list of statistics for an SDLC link station.
OBJECT-TYPE    
  SdlcLSStatsEntry  

sdlcLSStatsBLUsIn 1.3.6.1.2.1.41.1.2.3.1.1
This object reflects the total basic link units (BLUs; frames) received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsBLUsOut 1.3.6.1.2.1.41.1.2.3.1.2
This object reflects the total basic link units (BLUs; frames), transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsOctetsIn 1.3.6.1.2.1.41.1.2.3.1.3
This object reflects the total octets received from an adjacent SDLC link station since link station startup. This object covers the address, control, and information field of I-Frames only. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsOctetsOut 1.3.6.1.2.1.41.1.2.3.1.4
This object reflects the total octets transmitted to an adjacent SDLC link station since link station startup. This object covers the address, control, and information field of I-Frames only. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsPollsIn 1.3.6.1.2.1.41.1.2.3.1.5
This object reflects the total polls received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsPollsOut 1.3.6.1.2.1.41.1.2.3.1.6
This object reflects the total polls sent to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsPollRspsOut 1.3.6.1.2.1.41.1.2.3.1.7
This object reflects the total number of poll responses sent to the adjacent SDLC link station since link station startup. This value includes I-frames that are sent in response to a poll. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsPollRspsIn 1.3.6.1.2.1.41.1.2.3.1.8
This object reflects the total number of poll responses received from the adjacent SDLC link station since station startup. This value includes I-frames that are received in response to a poll. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsLocalBusies 1.3.6.1.2.1.41.1.2.3.1.9
This object reflects the total number of times that the local SDLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRemoteBusies 1.3.6.1.2.1.41.1.2.3.1.10
This object reflects the total number of times that an adjacent ( remote) SDLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsIFramesIn 1.3.6.1.2.1.41.1.2.3.1.11
This object reflects the total I-frames received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsIFramesOut 1.3.6.1.2.1.41.1.2.3.1.12
This object reflects the total I-frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsUIFramesIn 1.3.6.1.2.1.41.1.2.3.1.13
This object reflects the total UI-frames received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsUIFramesOut 1.3.6.1.2.1.41.1.2.3.1.14
This object reflects the total UI-frames transmitted to an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsXIDsIn 1.3.6.1.2.1.41.1.2.3.1.15
This object reflects the total XID frames received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsXIDsOut 1.3.6.1.2.1.41.1.2.3.1.16
This object reflects the total XID frames transmitted to an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsTESTsIn 1.3.6.1.2.1.41.1.2.3.1.17
This object reflects the total TEST frames, commands or responses, received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsTESTsOut 1.3.6.1.2.1.41.1.2.3.1.18
This object reflects the total TEST frames, commands or responses, transmitted to an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsREJsIn 1.3.6.1.2.1.41.1.2.3.1.19
This object reflects the total REJ frames received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsREJsOut 1.3.6.1.2.1.41.1.2.3.1.20
This object reflects the total REJ frames transmitted to an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsFRMRsIn 1.3.6.1.2.1.41.1.2.3.1.21
This object reflects the total frame reject (FRMR) frames received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsFRMRsOut 1.3.6.1.2.1.41.1.2.3.1.22
This object reflects the total frame reject (FRMR) frames transmitted to an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsSIMsIn 1.3.6.1.2.1.41.1.2.3.1.23
This object reflects the total set initialization mode (SIM) frames received from an adjacent SDLC link station since link station startup.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsSIMsOut 1.3.6.1.2.1.41.1.2.3.1.24
This object reflects the total set initialization mode (SIM) frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRIMsIn 1.3.6.1.2.1.41.1.2.3.1.25
This object reflects the total request initialization mode (RIM) frames received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRIMsOut 1.3.6.1.2.1.41.1.2.3.1.26
This object reflects the total request initialization mode (RIM) frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsDISCIn 1.3.6.1.2.1.41.1.2.3.1.27
This object reflects the total number of disconnect (DISC) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsDISCOut 1.3.6.1.2.1.41.1.2.3.1.28
This object reflects the total number of disconnect (DISC) requests transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsUAIn 1.3.6.1.2.1.41.1.2.3.1.29
This object reflects the total number of unnumbered acknowledgements (UA) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsUAOut 1.3.6.1.2.1.41.1.2.3.1.30
This object reflects the total number of unnumbered acknowledgements (UA) requests transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsDMIn 1.3.6.1.2.1.41.1.2.3.1.31
This object reflects the total number of disconnect mode (DM) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsDMOut 1.3.6.1.2.1.41.1.2.3.1.32
This object reflects the total number of disconnect mode (DM) requests transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsSNRMIn 1.3.6.1.2.1.41.1.2.3.1.33
This object reflects the total number of set normal response mode (SNRM/SNRME) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsSNRMOut 1.3.6.1.2.1.41.1.2.3.1.34
This object reflects the total number of set normal response mode (SNRM/SNRME) requests transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsProtocolErrs 1.3.6.1.2.1.41.1.2.3.1.35
This object reflects the total occurrences, since link station startup, where this SDLC link station has inactivated the link as a result of receiving a frame from its adjacent link station which was in violation of the protocol. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsActivityTOs 1.3.6.1.2.1.41.1.2.3.1.36
This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of no activity on the link. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRNRLIMITs 1.3.6.1.2.1.41.1.2.3.1.37
This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of its RNRLIMIT timer expiring. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRetriesExps 1.3.6.1.2.1.41.1.2.3.1.38
This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of a retry sequence being exhausted. At link station startup time, this object must be initialized to zero.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRetransmitsIn 1.3.6.1.2.1.41.1.2.3.1.39
This object reflects the total number of information frames retransmitted by the remote link station because the N(s) received from that link station indicated that one or more information frames sent by that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero. Management: If the value of sdlcLSStatsRetransmitsIn grows over time, then the quality of the serial line is in question. You might want to look at decreasing the value for sdlcLSAdminMAXDATASend to compensate for the lower quality line.
OBJECT-TYPE    
  Counter32  

sdlcLSStatsRetransmitsOut 1.3.6.1.2.1.41.1.2.3.1.40
This object reflects the total number of information frames retransmitted to a remote link station because the N(r) received from that link station indicated that one or more information frames sent to that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero. Management: If the value of sdlcLSStatsRetransmitsOut grows over time, then the quality of the serial line is in question. You might want to look at decreasing the value for sdlcLSAdminMAXDATASend to compensate for the lower quality line.
OBJECT-TYPE    
  Counter32  

sdlcTraps 1.3.6.1.2.1.41.1.3
OBJECT IDENTIFIER    

sdlcPortStatusChange 1.3.6.1.2.1.41.1.3.1
This trap indicates that the state of an SDLC port has transitioned to active or inactive.
NOTIFICATION-TYPE    
  ifIndex  
  ifAdminStatus  
  ifOperStatus  
  sdlcPortOperLastFailTime  
  sdlcPortOperLastFailCause  

sdlcLSStatusChange 1.3.6.1.2.1.41.1.3.2
This trap indicates that the state of an SDLC link station has transitioned to contacted or discontacted.
NOTIFICATION-TYPE    
  ifIndex  
  sdlcLSAddress  
  sdlcLSOperState  
  sdlcLSAdminState  
  sdlcLSOperLastFailTime  
  sdlcLSOperLastFailCause  
  sdlcLSOperLastFailFRMRInfo  
  sdlcLSOperLastFailCtrlIn  
  sdlcLSOperLastFailCtrlOut  
  sdlcLSOperLastFailREPLYTOs  

sdlcLSStatusChange1 1.3.6.1.2.1.41.1.3.3
This trap indicates that the state of an SDLC link station has transitioned to contacted or discontacted.
NOTIFICATION-TYPE    
  sdlcLSOperState  
  sdlcLSAdminState  
  sdlcLSOperLastFailTime  
  sdlcLSOperLastFailCause  
  sdlcLSOperLastFailFRMRInfo  
  sdlcLSOperLastFailCtrlIn  
  sdlcLSOperLastFailCtrlOut  
  sdlcLSOperLastFailREPLYTOs  

sdlcConformance 1.3.6.1.2.1.41.1.4
OBJECT IDENTIFIER    

sdlcCompliances 1.3.6.1.2.1.41.1.4.1
OBJECT IDENTIFIER    

sdlcCoreCompliance 1.3.6.1.2.1.41.1.4.1.1
The core compliance statement for all SDLC nodes.
MODULE-COMPLIANCE    

sdlcPrimaryCompliance 1.3.6.1.2.1.41.1.4.1.2
The compliance statement for all nodes that are performing the role of a Primary link station.
MODULE-COMPLIANCE    

sdlcPrimaryMultipointCompliance 1.3.6.1.2.1.41.1.4.1.3
The compliance statement for all nodes that are performing the role of a primary link station on a multipoint line.
MODULE-COMPLIANCE    

sdlcCoreComplianceV11R01 1.3.6.1.2.1.41.1.4.1.4
The core compliance statement for all SDLC nodes.
MODULE-COMPLIANCE    

sdlcGroups 1.3.6.1.2.1.41.1.4.2
OBJECT IDENTIFIER    

sdlcCoreGroups 1.3.6.1.2.1.41.1.4.2.1
OBJECT IDENTIFIER    

sdlcCorePortAdminGroup 1.3.6.1.2.1.41.1.4.2.1.1
The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations.
OBJECT-GROUP    

sdlcCorePortOperGroup 1.3.6.1.2.1.41.1.4.2.1.2
The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations.
OBJECT-GROUP    

sdlcCorePortStatsGroup 1.3.6.1.2.1.41.1.4.2.1.3
The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSAdminGroup 1.3.6.1.2.1.41.1.4.2.1.4
The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSOperGroup 1.3.6.1.2.1.41.1.4.2.1.5
The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSStatsGroup 1.3.6.1.2.1.41.1.4.2.1.6
The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations.
OBJECT-GROUP    

sdlcCorePortAdminGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.7
The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations.
OBJECT-GROUP    

sdlcCorePortOperGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.8
The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations.
OBJECT-GROUP    

sdlcCorePortStatsGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.9
The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSAdminGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.10
The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSOperGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.11
The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations.
OBJECT-GROUP    

sdlcCoreLSStatsGroupV11R01 1.3.6.1.2.1.41.1.4.2.1.12
The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations.
OBJECT-GROUP    

sdlcPrimaryGroups 1.3.6.1.2.1.41.1.4.2.2
OBJECT IDENTIFIER    

sdlcPrimaryGroup 1.3.6.1.2.1.41.1.4.2.2.1
The sdlcPrimaryGroup defines objects which are common to all compliant primary link stations.
OBJECT-GROUP    

sdlcPrimaryMultipointGroup 1.3.6.1.2.1.41.1.4.2.2.2
The sdlcPrimaryMultipointGroup defines objects which are common to all compliant primary link stations that are in a multipoint topology.
OBJECT-GROUP    

Defined Objects

SdlcPortAdminEntry  
SEQUENCE    
  DisplayString as sdlcPortAdminName  
  INTEGER as sdlcPortAdminRole  
  INTEGER as sdlcPortAdminType  
  INTEGER as sdlcPortAdminTopology  
  INTEGER as sdlcPortAdminISTATUS  
  TimeInterval as sdlcPortAdminACTIVTO  
  TimeInterval as sdlcPortAdminPAUSE  
  Integer32 as sdlcPortAdminSERVLIM  
  TimeInterval as sdlcPortAdminSlowPollTimer  

SdlcPortOperEntry  
SEQUENCE    
  DisplayString as sdlcPortOperName  
  INTEGER as sdlcPortOperRole  
  INTEGER as sdlcPortOperType  
  INTEGER as sdlcPortOperTopology  
  INTEGER as sdlcPortOperISTATUS  
  TimeInterval as sdlcPortOperACTIVTO  
  TimeInterval as sdlcPortOperPAUSE  
  INTEGER as sdlcPortOperSlowPollMethod  
  Integer32 as sdlcPortOperSERVLIM  
  TimeInterval as sdlcPortOperSlowPollTimer  
  TimeTicks as sdlcPortOperLastModifyTime  
  TimeTicks as sdlcPortOperLastFailTime  
  INTEGER as sdlcPortOperLastFailCause  

SdlcPortStatsEntry  
SEQUENCE    
  Counter32 as sdlcPortStatsPhysicalFailures  
  Counter32 as sdlcPortStatsInvalidAddresses  
  Counter32 as sdlcPortStatsDwarfFrames  
  Counter32 as sdlcPortStatsPollsIn  
  Counter32 as sdlcPortStatsPollsOut  
  Counter32 as sdlcPortStatsPollRspsIn  
  Counter32 as sdlcPortStatsPollRspsOut  
  Counter32 as sdlcPortStatsLocalBusies  
  Counter32 as sdlcPortStatsRemoteBusies  
  Counter32 as sdlcPortStatsIFramesIn  
  Counter32 as sdlcPortStatsIFramesOut  
  Counter32 as sdlcPortStatsOctetsIn  
  Counter32 as sdlcPortStatsOctetsOut  
  Counter32 as sdlcPortStatsProtocolErrs  
  Counter32 as sdlcPortStatsActivityTOs  
  Counter32 as sdlcPortStatsRNRLIMITs  
  Counter32 as sdlcPortStatsRetriesExps  
  Counter32 as sdlcPortStatsRetransmitsIn  
  Counter32 as sdlcPortStatsRetransmitsOut  

SdlcLSAdminEntry  
SEQUENCE    
  INTEGER as sdlcLSAddress  
  DisplayString as sdlcLSAdminName  
  INTEGER as sdlcLSAdminState  
  INTEGER as sdlcLSAdminISTATUS  
  Integer32 as sdlcLSAdminMAXDATASend  
  Integer32 as sdlcLSAdminMAXDATARcv  
  TimeInterval as sdlcLSAdminREPLYTO  
  INTEGER as sdlcLSAdminMAXIN  
  INTEGER as sdlcLSAdminMAXOUT  
  INTEGER as sdlcLSAdminMODULO  
  INTEGER as sdlcLSAdminRETRIESm  
  TimeInterval as sdlcLSAdminRETRIESt  
  Integer32 as sdlcLSAdminRETRIESn  
  TimeInterval as sdlcLSAdminRNRLIMIT  
  INTEGER as sdlcLSAdminDATMODE  
  INTEGER as sdlcLSAdminGPoll  
  INTEGER as sdlcLSAdminSimRim  
  INTEGER as sdlcLSAdminXmitRcvCap  
  RowStatus as sdlcLSAdminRowStatus  

SdlcLSOperEntry  
SEQUENCE    
  DisplayString as sdlcLSOperName  
  INTEGER as sdlcLSOperRole  
  INTEGER as sdlcLSOperState  
  Integer32 as sdlcLSOperMAXDATASend  
  TimeInterval as sdlcLSOperREPLYTO  
  INTEGER as sdlcLSOperMAXIN  
  INTEGER as sdlcLSOperMAXOUT  
  INTEGER as sdlcLSOperMODULO  
  INTEGER as sdlcLSOperRETRIESm  
  TimeInterval as sdlcLSOperRETRIESt  
  INTEGER as sdlcLSOperRETRIESn  
  TimeInterval as sdlcLSOperRNRLIMIT  
  INTEGER as sdlcLSOperDATMODE  
  TimeTicks as sdlcLSOperLastModifyTime  
  TimeTicks as sdlcLSOperLastFailTime  
  INTEGER as sdlcLSOperLastFailCause  
  OCTET STRING as sdlcLSOperLastFailCtrlIn  
  OCTET STRING as sdlcLSOperLastFailCtrlOut  
  OCTET STRING as sdlcLSOperLastFailFRMRInfo  
  Counter32 as sdlcLSOperLastFailREPLYTOs  
  INTEGER as sdlcLSOperEcho  
  INTEGER as sdlcLSOperGPoll  
  INTEGER as sdlcLSOperSimRim  
  INTEGER as sdlcLSOperXmitRcvCap  

SdlcLSStatsEntry  
SEQUENCE    
  Counter32 as sdlcLSStatsBLUsIn  
  Counter32 as sdlcLSStatsBLUsOut  
  Counter32 as sdlcLSStatsOctetsIn  
  Counter32 as sdlcLSStatsOctetsOut  
  Counter32 as sdlcLSStatsPollsIn  
  Counter32 as sdlcLSStatsPollsOut  
  Counter32 as sdlcLSStatsPollRspsIn  
  Counter32 as sdlcLSStatsPollRspsOut  
  Counter32 as sdlcLSStatsLocalBusies  
  Counter32 as sdlcLSStatsRemoteBusies  
  Counter32 as sdlcLSStatsIFramesIn  
  Counter32 as sdlcLSStatsIFramesOut  
  Counter32 as sdlcLSStatsUIFramesIn  
  Counter32 as sdlcLSStatsUIFramesOut  
  Counter32 as sdlcLSStatsXIDsIn  
  Counter32 as sdlcLSStatsXIDsOut  
  Counter32 as sdlcLSStatsTESTsIn  
  Counter32 as sdlcLSStatsTESTsOut  
  Counter32 as sdlcLSStatsREJsIn  
  Counter32 as sdlcLSStatsREJsOut  
  Counter32 as sdlcLSStatsFRMRsIn  
  Counter32 as sdlcLSStatsFRMRsOut  
  Counter32 as sdlcLSStatsSIMsIn  
  Counter32 as sdlcLSStatsSIMsOut  
  Counter32 as sdlcLSStatsRIMsIn  
  Counter32 as sdlcLSStatsRIMsOut  
  Counter32 as sdlcLSStatsDISCIn  
  Counter32 as sdlcLSStatsDISCOut  
  Counter32 as sdlcLSStatsUAIn  
  Counter32 as sdlcLSStatsUAOut  
  Counter32 as sdlcLSStatsDMIn  
  Counter32 as sdlcLSStatsDMOut  
  Counter32 as sdlcLSStatsSNRMIn  
  Counter32 as sdlcLSStatsSNRMOut  
  Counter32 as sdlcLSStatsProtocolErrs  
  Counter32 as sdlcLSStatsActivityTOs  
  Counter32 as sdlcLSStatsRNRLIMITs  
  Counter32 as sdlcLSStatsRetriesExps  
  Counter32 as sdlcLSStatsRetransmitsIn  