NETBOTZ-PRD-BOT-MIB

File: NETBOTZ-PRD-BOT-MIB.mib (78670 bytes)

Imported modules

RFC-1212 RFC-1215 NETBOTZ-DEVICE-MIB
NETBOTZ-PRODUCTS-MIB NETBOTZ-MIB RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE netBotz-ismetric
netBotz-prd-bot netBotz-products DisplayString
IpAddress

Defined Objects

netBotz-prd-bot-temp 1.3.6.1.4.1.5528.30.10.1
The reading of the temperature probe, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-low-trap 1.3.6.1.4.1.5528.30.10.1
Netbotz Low Trap. This trap indicates that a lower limit has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity 1.3.6.1.4.1.5528.30.10.2
The reading of the humidity probe, in percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-high-trap 1.3.6.1.4.1.5528.30.10.2
Netbotz High Trap. This trap indicates that an upper limit has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow 1.3.6.1.4.1.5528.30.10.3
The reading of the airflow probe. Each unit represents approximately 40 feet/minute or 13 meters/minute of airflow velocity.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-clear 1.3.6.1.4.1.5528.30.10.3
Netbotz Cleared Trap. The trap has been cleared because the value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio 1.3.6.1.4.1.5528.30.10.4
The reading of the audio alarm probe on/off.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-offline-trap 1.3.6.1.4.1.5528.30.10.4
Netbotz Device Offline Trap. This trap indicates that a device or function has been determined to be offline.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-doorajar 1.3.6.1.4.1.5528.30.10.5
The reading of the door switch probe open(0) or closed(1).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-online-trap 1.3.6.1.4.1.5528.30.10.5
Netbotz Device Online Trap. This trap indicates that a device or function has been determined to be online.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temp-min 1.3.6.1.4.1.5528.30.10.6
The temperature probe minimum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-temp-max 1.3.6.1.4.1.5528.30.10.7
The temperature probe maximum, from 35 to 120 degrees F, or 1 to 50 degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-humidity-min 1.3.6.1.4.1.5528.30.10.8
The humidity probe minimum, from 10 to 90 percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-humidity-max 1.3.6.1.4.1.5528.30.10.9
The humidity probe maximum, from 10 to 90 percent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-airflow-mins 1.3.6.1.4.1.5528.30.10.10
Minutes without airflow before alarm set.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-secs 1.3.6.1.4.1.5528.30.10.11
Seconds of alarm audio before alarm set.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-temp-enabled 1.3.6.1.4.1.5528.30.10.12
Temperature probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-hum-enabled 1.3.6.1.4.1.5528.30.10.13
Humidity probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-air-enabled 1.3.6.1.4.1.5528.30.10.14
Airflow probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-enabled 1.3.6.1.4.1.5528.30.10.15
Audio probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-switch-state 1.3.6.1.4.1.5528.30.10.16
Switch state setting. The state controls which condition of the door switch indicates an alarm. If set to 0, alarm is set when the switch is closed. If set to 1, alarm is set when the switch is open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-switch-enabled 1.3.6.1.4.1.5528.30.10.17
Door switch enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-audio-level 1.3.6.1.4.1.5528.30.10.18
Audio level setting. This is the relative audio level, from 0-11, above which an alarm will be sent.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-doorpic-delay 1.3.6.1.4.1.5528.30.10.19
Number of seconds between door alert and first picture.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-index 1.3.6.1.4.1.5528.30.10.20
The crawler ID of the last trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-address 1.3.6.1.4.1.5528.30.10.21
The IP address of the last trap.
OBJECT-TYPE    
  IpAddress  

netBotz-prd-bot-trap-oid 1.3.6.1.4.1.5528.30.10.22
The object id of the last trap.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

netBotz-prd-bot-trap-value 1.3.6.1.4.1.5528.30.10.23
The value of the last object trap.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-trap-date 1.3.6.1.4.1.5528.30.10.24
The date and time of a specific trap. This field contains the number of seconds elapsed since midnight (00:00:00), January 1, 1970
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-refresh 1.3.6.1.4.1.5528.30.10.26
Rate of web page refresh, in seconds. This must be greater than 5 seconds.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-airflow-level 1.3.6.1.4.1.5528.30.10.27
Airflow alert level. This is the relative level of airflow below which an alarm will be sent. The range is 1-11. Each unit is approximately 40 feet/second or 13 meters/second of airflow velocity.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-doorpic-count 1.3.6.1.4.1.5528.30.10.28
Number of pictures to take when door activated. These pictures will be sent as attachments to the door alert e-mail. The range is from 0 to 5 pictures.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1 1.3.6.1.4.1.5528.30.10.29
The reading of the first amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-enabled 1.3.6.1.4.1.5528.30.10.30
Amperage[1] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-min 1.3.6.1.4.1.5528.30.10.31
The amperage[1] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-max 1.3.6.1.4.1.5528.30.10.32
The amperage[1] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2 1.3.6.1.4.1.5528.30.10.34
The reading of the second amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-enabled 1.3.6.1.4.1.5528.30.10.35
Amperage[2] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-min 1.3.6.1.4.1.5528.30.10.36
The amperage[2] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-max 1.3.6.1.4.1.5528.30.10.37
The amperage[2] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3 1.3.6.1.4.1.5528.30.10.39
The reading of the third amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-enabled 1.3.6.1.4.1.5528.30.10.40
Amperage[3] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-min 1.3.6.1.4.1.5528.30.10.41
The amperage[3] probe minimum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-max 1.3.6.1.4.1.5528.30.10.42
The amperage[3] probe maximum, from 0 to 30000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total 1.3.6.1.4.1.5528.30.10.44
The total of the readings of all amperage probes, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-enabled 1.3.6.1.4.1.5528.30.10.45
Total amperage alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-min 1.3.6.1.4.1.5528.30.10.46
The total amperage minimum, from 0 to 90000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-max 1.3.6.1.4.1.5528.30.10.47
The total amperage maximum, from 0 to 90000 milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps-total-support-enabled 1.3.6.1.4.1.5528.30.10.48
Total Amperage Support enabled(Y) or disabled(N).
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-amps1-uV-per-10mA 1.3.6.1.4.1.5528.30.10.49
The scaling factor used for the first amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-uV-per-10mA 1.3.6.1.4.1.5528.30.10.50
The scaling factor used for the second amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-uV-per-mA 1.3.6.1.4.1.5528.30.10.51
The scaling factor used for the third amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps1-max-range 1.3.6.1.4.1.5528.30.10.52
The maximum RMS milliamps measureable by the first Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps2-max-range 1.3.6.1.4.1.5528.30.10.53
The maximum RMS milliamps measureable by the second Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps3-max-range 1.3.6.1.4.1.5528.30.10.54
The maximum RMS milliamps measureable by the third Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4 1.3.6.1.4.1.5528.30.10.55
The reading of the fourth amperage probe, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-enabled 1.3.6.1.4.1.5528.30.10.56
Amperage[4] probe alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-min 1.3.6.1.4.1.5528.30.10.57
The amperage[4] probe minimum, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-max 1.3.6.1.4.1.5528.30.10.58
The amperage[4] probe maximum, in milliamps.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-uV-per-10mA 1.3.6.1.4.1.5528.30.10.60
The scaling factor used for the fourth amperage probe to convert microvolts measured from the Amp Detect into 10s of milliamps of current. Needs to be set based on the type of Amp Detect module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amps4-max-range 1.3.6.1.4.1.5528.30.10.61
The maximum RMS milliamps measureable by the fourth Amp Detect.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1 1.3.6.1.4.1.5528.30.10.62
The reading of the external temperature probe on port 1, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2 1.3.6.1.4.1.5528.30.10.63
The reading of the external temperature probe on port 2, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3 1.3.6.1.4.1.5528.30.10.64
The reading of the external temperature probe on port 3, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4 1.3.6.1.4.1.5528.30.10.65
The reading of the external temperature probe on port 4, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-enabled 1.3.6.1.4.1.5528.30.10.66
External temperature probe on port 1 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-min 1.3.6.1.4.1.5528.30.10.67
The external temperature probe on port 1 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-max 1.3.6.1.4.1.5528.30.10.68
The external temperature probe on port 1 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-enabled 1.3.6.1.4.1.5528.30.10.69
External temperature probe on port 2 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-min 1.3.6.1.4.1.5528.30.10.70
The external temperature probe on port 2 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-max 1.3.6.1.4.1.5528.30.10.71
The external temperature probe on port 2 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-enabled 1.3.6.1.4.1.5528.30.10.72
External temperature probe on port 3 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-min 1.3.6.1.4.1.5528.30.10.73
The external temperature probe on port 3 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-max 1.3.6.1.4.1.5528.30.10.74
The external temperature probe on port 3 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-enabled 1.3.6.1.4.1.5528.30.10.75
External temperature probe on port 4 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-min 1.3.6.1.4.1.5528.30.10.76
The external temperature probe on port 4 probe minimum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-max 1.3.6.1.4.1.5528.30.10.77
The external temperature probe on port 4 probe maximum, in degrees F or degrees C (depends on netBotz-ismetric).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.78
The scaling factor used for the external temperature probe on port 1 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.79
The offset used for the external temperature probe on port 1 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-min-range 1.3.6.1.4.1.5528.30.10.80
The minimum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp1-max-range 1.3.6.1.4.1.5528.30.10.81
The maximum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.82
The scaling factor used for the external temperature probe on port 2 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.83
The offset used for the external temperature probe on port 2 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-min-range 1.3.6.1.4.1.5528.30.10.84
The minimum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp2-max-range 1.3.6.1.4.1.5528.30.10.85
The maximum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.86
The scaling factor used for the external temperature probe on port 3 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.87
The offset used for the external temperature probe on port 3 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-min-range 1.3.6.1.4.1.5528.30.10.88
The minimum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp3-max-range 1.3.6.1.4.1.5528.30.10.89
The maximum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-uV-per-degreeC 1.3.6.1.4.1.5528.30.10.90
The scaling factor used for the external temperature probe on port 4 to convert microvolts measured from the temperature sensor into degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-uV-at-0-degreeC 1.3.6.1.4.1.5528.30.10.91
The offset used for the external temperature probe on port 4 of microvolts measured from the temperature sensor at zero degrees C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-min-range 1.3.6.1.4.1.5528.30.10.92
The minimum temperature measureable by the temperature sensor installed on port 4, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-temp4-max-range 1.3.6.1.4.1.5528.30.10.93
The maximum temperature measureable by the temperature sensor installed on port 4, in tenths of a degree C. Needs to be set based on the type of temperature sensor module installed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-port1-module-id 1.3.6.1.4.1.5528.30.10.94
The module ID of the sensor module installed on port 1. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port1-module-type 1.3.6.1.4.1.5528.30.10.95
The type of sensor module installed on port 1. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port2-module-id 1.3.6.1.4.1.5528.30.10.96
The module ID of the sensor module installed on port 2. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port2-module-type 1.3.6.1.4.1.5528.30.10.97
The type of sensor module installed on port 2. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port3-module-id 1.3.6.1.4.1.5528.30.10.98
The module ID of the sensor module installed on port 3. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port3-module-type 1.3.6.1.4.1.5528.30.10.99
The type of sensor module installed on port 3. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port4-module-id 1.3.6.1.4.1.5528.30.10.100
The module ID of the sensor module installed on port 4. Blank string indicates that no module is installed.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-port4-module-type 1.3.6.1.4.1.5528.30.10.101
The type of sensor module installed on port 4. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact sensor.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-amp1-total-amp-seconds 1.3.6.1.4.1.5528.30.10.102
The accumulated total of amp-seconds on the AmpDetect on port 1.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp1-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.103
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 1. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp2-total-amp-seconds 1.3.6.1.4.1.5528.30.10.104
The accumulated total of amp-seconds on the AmpDetect on port 2.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp2-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.105
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 2. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp3-total-amp-seconds 1.3.6.1.4.1.5528.30.10.106
The accumulated total of amp-seconds on the AmpDetect on port 3.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp3-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.107
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 3. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp4-total-amp-seconds 1.3.6.1.4.1.5528.30.10.108
The accumulated total of amp-seconds on the AmpDetect on port 4.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amp4-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.109
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 4. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amptotal-total-amp-seconds 1.3.6.1.4.1.5528.30.10.110
The accumulated total of amp-seconds on the total of all AmpDetects.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-amptotal-total-amp-seconds-since-time 1.3.6.1.4.1.5528.30.10.111
The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds for all AmpDetects. Writing a value to this attribute resets the accumulated total amp-seconds and sets this time to the current time.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1 1.3.6.1.4.1.5528.30.10.112
The current value of the external dry contact sensor on Ext1: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2 1.3.6.1.4.1.5528.30.10.113
The current value of the external dry contact sensor on Ext2: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3 1.3.6.1.4.1.5528.30.10.114
The current value of the external dry contact sensor on Ext3: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4 1.3.6.1.4.1.5528.30.10.115
The current value of the external dry contact sensor on Ext4: 0=Open, 1=Closed, -1=N/A
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-alarm-value 1.3.6.1.4.1.5528.30.10.116
The value to generate alarms on for the external dry contact sensor on Ext1: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-enabled 1.3.6.1.4.1.5528.30.10.117
External dry contact sensor on Ext1 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-alarm-value 1.3.6.1.4.1.5528.30.10.118
The value to generate alarms on for the external dry contact sensor on Ext2: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-enabled 1.3.6.1.4.1.5528.30.10.119
External dry contact sensor on Ext2 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-alarm-value 1.3.6.1.4.1.5528.30.10.120
The value to generate alarms on for the external dry contact sensor on Ext3: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-enabled 1.3.6.1.4.1.5528.30.10.121
External dry contact sensor on Ext3 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-alarm-value 1.3.6.1.4.1.5528.30.10.122
The value to generate alarms on for the external dry contact sensor on Ext4: 0=Open, 1=Closed
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-enabled 1.3.6.1.4.1.5528.30.10.123
External dry contact sensor on Ext4 alarm enabled(1) or disabled(0).
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-label 1.3.6.1.4.1.5528.30.10.124
The sensor name/label for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-open-label 1.3.6.1.4.1.5528.30.10.125
The sensor name/label for the open(0) state for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-closed-label 1.3.6.1.4.1.5528.30.10.126
The sensor name/label for the closed(0) state for the dry contact sensor on Ext1
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry1-open-to-close-millis 1.3.6.1.4.1.5528.30.10.127
The minimum number of milliseconds that the dry contact sensor on Ext1 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-close-to-open-millis 1.3.6.1.4.1.5528.30.10.128
The minimum number of milliseconds that the dry contact sensor on Ext1 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry1-response 1.3.6.1.4.1.5528.30.10.129
The type of alert response for the dry contact sensor on Ext1: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-label 1.3.6.1.4.1.5528.30.10.130
The sensor name/label for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-open-label 1.3.6.1.4.1.5528.30.10.131
The sensor name/label for the open(0) state for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-closed-label 1.3.6.1.4.1.5528.30.10.132
The sensor name/label for the closed(0) state for the dry contact sensor on Ext2
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry2-open-to-close-millis 1.3.6.1.4.1.5528.30.10.133
The minimum number of milliseconds that the dry contact sensor on Ext2 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-close-to-open-millis 1.3.6.1.4.1.5528.30.10.134
The minimum number of milliseconds that the dry contact sensor on Ext2 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry2-response 1.3.6.1.4.1.5528.30.10.135
The type of alert response for the dry contact sensor on Ext2: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-label 1.3.6.1.4.1.5528.30.10.136
The sensor name/label for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-open-label 1.3.6.1.4.1.5528.30.10.137
The sensor name/label for the open(0) state for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-closed-label 1.3.6.1.4.1.5528.30.10.138
The sensor name/label for the closed(0) state for the dry contact sensor on Ext3
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry3-open-to-close-millis 1.3.6.1.4.1.5528.30.10.139
The minimum number of milliseconds that the dry contact sensor on Ext3 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-close-to-open-millis 1.3.6.1.4.1.5528.30.10.140
The minimum number of milliseconds that the dry contact sensor on Ext3 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry3-response 1.3.6.1.4.1.5528.30.10.141
The type of alert response for the dry contact sensor on Ext3: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry4-label 1.3.6.1.4.1.5528.30.10.142
The sensor name/label for the dry contact sensor on Ext4
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry4-open-label 1.3.6.1.4.1.5528.30.10.143
The sensor name/label for the open(0) state for the dry contact sensor on Ext4
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry4-closed-label 1.3.6.1.4.1.5528.30.10.144
The sensor name/label for the closed(0) state for the dry contact sensor on Ext4
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-ext-dry4-open-to-close-millis 1.3.6.1.4.1.5528.30.10.145
The minimum number of milliseconds that the dry contact sensor on Ext4 must read closed before the state is changed from open to closed.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-close-to-open-millis 1.3.6.1.4.1.5528.30.10.146
The minimum number of milliseconds that the dry contact sensor on Ext4 must read openbefore the state is changed from closed to open.
OBJECT-TYPE    
  INTEGER  

netBotz-prd-bot-ext-dry4-response 1.3.6.1.4.1.5528.30.10.147
The type of alert response for the dry contact sensor on Ext4: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from camera.
OBJECT-TYPE    
  DisplayString  

netBotz-prd-bot-traps 1.3.6.1.4.1.5528.30.100
OBJECT IDENTIFIER    

netBotz-prd-bot-temperature-traps 1.3.6.1.4.1.5528.30.100.1
OBJECT IDENTIFIER    

netBotz-prd-bot-temperature-low-trap 1.3.6.1.4.1.5528.30.100.1.1
Netbotz Temperature Low Trap. This trap indicates that the lower limit for temperature has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temperature-high-trap 1.3.6.1.4.1.5528.30.100.1.2
Netbotz Temperature High Trap. This trap indicates that the upper limit for temperature has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-temperature-trap-clear 1.3.6.1.4.1.5528.30.100.1.3
Netbotz Temperature Cleared Trap. The trap has been cleared because the temperature value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-traps 1.3.6.1.4.1.5528.30.100.2
OBJECT IDENTIFIER    

netBotz-prd-bot-humidity-low-trap 1.3.6.1.4.1.5528.30.100.2.1
Netbotz Humidity Low Trap. This trap indicates that the lower limit for humidity has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-high-trap 1.3.6.1.4.1.5528.30.100.2.2
Netbotz Humidity High Trap. This trap indicates that the upper limit for humidity has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-humidity-trap-clear 1.3.6.1.4.1.5528.30.100.2.3
Netbotz Humidity Cleared Trap. The trap has been cleared because the humidity value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow-traps 1.3.6.1.4.1.5528.30.100.3
OBJECT IDENTIFIER    

netBotz-prd-bot-airflow-low-trap 1.3.6.1.4.1.5528.30.100.3.1
Netbotz Airflow Low Trap. This trap indicates that the lower limit for airflow has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-airflow-trap-clear 1.3.6.1.4.1.5528.30.100.3.3
Netbotz Airflow Cleared Trap. The trap has been cleared because the airflow value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio-traps 1.3.6.1.4.1.5528.30.100.4
OBJECT IDENTIFIER    

netBotz-prd-bot-audio-high-trap 1.3.6.1.4.1.5528.30.100.4.2
Netbotz Audio High Trap. This trap indicates that the upper limit for audio has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-audio-trap-clear 1.3.6.1.4.1.5528.30.100.4.3
Netbotz Audio Cleared Trap. The trap has been cleared because the audio value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-door-traps 1.3.6.1.4.1.5528.30.100.5
OBJECT IDENTIFIER    

netBotz-prd-bot-door-trap-tripped 1.3.6.1.4.1.5528.30.100.5.2
Netbotz Door Sensor Tripped Trap. This trap indicates that the door sensor has been triggered (i.e. opened, if the thresdhold has been set to trip on open, closed if otherwise).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-door-trap-clear 1.3.6.1.4.1.5528.30.100.5.3
Netbotz Door Cleared Trap. The trap has been cleared because the door sensor has returned to normal (i.e. been closed, if the threshold has been set to trip on open).
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-traps 1.3.6.1.4.1.5528.30.100.6
OBJECT IDENTIFIER    

netBotz-prd-bot-amp1-low-trap 1.3.6.1.4.1.5528.30.100.6.1
Netbotz Amp1 Low Trap. This trap indicates that the lower limit for the first amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-high-trap 1.3.6.1.4.1.5528.30.100.6.2
Netbotz Amp1 High Trap. This trap indicates that the upper limit for the first amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-trap-clear 1.3.6.1.4.1.5528.30.100.6.3
Netbotz Amp1 Cleared Trap. The trap has been cleared because the first amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-sensor-unplugged 1.3.6.1.4.1.5528.30.100.6.6
Netbotz Amp 1 Sensor Unplugged Trap. The sensor for the first AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp1-sensor-replugged 1.3.6.1.4.1.5528.30.100.6.7
Netbotz Amp 1 Sensor Replugged Trap. The sensor for the first AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-traps 1.3.6.1.4.1.5528.30.100.7
OBJECT IDENTIFIER    

netBotz-prd-bot-amp2-low-trap 1.3.6.1.4.1.5528.30.100.7.1
Netbotz Amp2 Low Trap. This trap indicates that the lower limit for the second amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-high-trap 1.3.6.1.4.1.5528.30.100.7.2
Netbotz Amp2 High Trap. This trap indicates that the upper limit for the second amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-trap-clear 1.3.6.1.4.1.5528.30.100.7.3
Netbotz Amp2 Cleared Trap. The trap has been cleared because the second amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-sensor-unplugged 1.3.6.1.4.1.5528.30.100.7.6
Netbotz Amp 2 Sensor Unplugged Trap. The sensor for the second AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp2-sensor-replugged 1.3.6.1.4.1.5528.30.100.7.7
Netbotz Amp 2 Sensor Replugged Trap. The sensor for the second AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-traps 1.3.6.1.4.1.5528.30.100.8
OBJECT IDENTIFIER    

netBotz-prd-bot-amp3-low-trap 1.3.6.1.4.1.5528.30.100.8.1
Netbotz Amp3 Low Trap. This trap indicates that the lower limit for the third amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-high-trap 1.3.6.1.4.1.5528.30.100.8.2
Netbotz Amp3 High Trap. This trap indicates that the upper limit for the third amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-trap-clear 1.3.6.1.4.1.5528.30.100.8.3
Netbotz Amp3 Cleared Trap. The trap has been cleared because the third amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-sensor-unplugged 1.3.6.1.4.1.5528.30.100.8.6
Netbotz Amp 3 Sensor Unplugged Trap. The sensor for the third AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp3-sensor-replugged 1.3.6.1.4.1.5528.30.100.8.7
Netbotz Amp 3 Sensor Replugged Trap. The sensor for the third AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-traps 1.3.6.1.4.1.5528.30.100.9
OBJECT IDENTIFIER    

netBotz-prd-bot-amp4-low-trap 1.3.6.1.4.1.5528.30.100.9.1
Netbotz Amp4 Low Trap. This trap indicates that the lower limit for the fourth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-high-trap 1.3.6.1.4.1.5528.30.100.9.2
Netbotz Amp4 High Trap. This trap indicates that the upper limit for the fourth amp detect has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-trap-clear 1.3.6.1.4.1.5528.30.100.9.3
Netbotz Amp4 Cleared Trap. The trap has been cleared because the fourth amp detect value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-sensor-unplugged 1.3.6.1.4.1.5528.30.100.9.6
Netbotz Amp 4 Sensor Unplugged Trap. The sensor for the fourth AmpDetect is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp4-sensor-replugged 1.3.6.1.4.1.5528.30.100.9.7
Netbotz Amp 4 Sensor Replugged Trap. The sensor for the fourth AmpDetect was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-traps 1.3.6.1.4.1.5528.30.100.10
OBJECT IDENTIFIER    

netBotz-prd-bot-amp-total-low-trap 1.3.6.1.4.1.5528.30.100.10.1
Netbotz Total Amps Low Trap. This trap indicates that the lower limit for the total amperage has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-high-trap 1.3.6.1.4.1.5528.30.100.10.2
Netbotz Total Amps High Trap. This trap indicates that the upper limit for the total amperage has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-amp-total-trap-clear 1.3.6.1.4.1.5528.30.100.10.3
Netbotz Total Amps Cleared Trap. The trap has been cleared because the total amperage value has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-traps 1.3.6.1.4.1.5528.30.100.11
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp1-low-trap 1.3.6.1.4.1.5528.30.100.11.1
Netbotz External Temperature 1 Low Trap. This trap indicates that the lower limit for external temperature probe on port 1 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-high-trap 1.3.6.1.4.1.5528.30.100.11.2
Netbotz External Temperature 1 High Trap. This trap indicates that the upper limit for external temperature probe on port 1 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-trap-clear 1.3.6.1.4.1.5528.30.100.11.3
Netbotz External Temperature 1 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 1 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-sensor-unplugged 1.3.6.1.4.1.5528.30.100.11.6
Netbotz External Temperature 1 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp1-sensor-replugged 1.3.6.1.4.1.5528.30.100.11.7
Netbotz External Temperature 1 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-traps 1.3.6.1.4.1.5528.30.100.12
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp2-low-trap 1.3.6.1.4.1.5528.30.100.12.1
Netbotz External Temperature 2 Low Trap. This trap indicates that the lower limit for external temperature probe on port 2 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-high-trap 1.3.6.1.4.1.5528.30.100.12.2
Netbotz External Temperature 2 High Trap. This trap indicates that the upper limit for external temperature probe on port 2 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-trap-clear 1.3.6.1.4.1.5528.30.100.12.3
Netbotz External Temperature 2 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 2 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-sensor-unplugged 1.3.6.1.4.1.5528.30.100.12.6
Netbotz External Temperature 2 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp2-sensor-replugged 1.3.6.1.4.1.5528.30.100.12.7
Netbotz External Temperature 2 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-traps 1.3.6.1.4.1.5528.30.100.13
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp3-low-trap 1.3.6.1.4.1.5528.30.100.13.1
Netbotz External Temperature 3 Low Trap. This trap indicates that the lower limit for external temperature probe on port 3 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-high-trap 1.3.6.1.4.1.5528.30.100.13.2
Netbotz External Temperature 3 High Trap. This trap indicates that the upper limit for external temperature probe on port 3 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-trap-clear 1.3.6.1.4.1.5528.30.100.13.3
Netbotz External Temperature 3 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 3 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-sensor-unplugged 1.3.6.1.4.1.5528.30.100.13.6
Netbotz External Temperature 3 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp3-sensor-replugged 1.3.6.1.4.1.5528.30.100.13.7
Netbotz External Temperature 3 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-traps 1.3.6.1.4.1.5528.30.100.14
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-temp4-low-trap 1.3.6.1.4.1.5528.30.100.14.1
Netbotz External Temperature 4 Low Trap. This trap indicates that the lower limit for external temperature probe on port 4 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-high-trap 1.3.6.1.4.1.5528.30.100.14.2
Netbotz External Temperature 4 High Trap. This trap indicates that the upper limit for external temperature probe on port 4 has been exceeded.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-trap-clear 1.3.6.1.4.1.5528.30.100.14.3
Netbotz External Temperature 4 Cleared Trap. The trap has been cleared because the temperature value for the temperature probe on port 4 has returned to acceptable limits.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-sensor-unplugged 1.3.6.1.4.1.5528.30.100.14.6
Netbotz External Temperature 4 Sensor Unplugged Trap. The sensor is unplugged or malfunctioning.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-temp4-sensor-replugged 1.3.6.1.4.1.5528.30.100.14.7
Netbotz External Temperature 4 Sensor Replugged Trap. The sensor was unplugged, but has been reconnected.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry1-traps 1.3.6.1.4.1.5528.30.100.15
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry1-triggered-trap 1.3.6.1.4.1.5528.30.100.15.2
Netbotz External Dry Contact 1 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext1 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry1-trap-clear 1.3.6.1.4.1.5528.30.100.15.3
Netbotz External Dry Contact 1 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext1 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry2-traps 1.3.6.1.4.1.5528.30.100.16
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry2-triggered-trap 1.3.6.1.4.1.5528.30.100.16.2
Netbotz External Dry Contact 2 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext2 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry2-trap-clear 1.3.6.1.4.1.5528.30.100.16.3
Netbotz External Dry Contact 2 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext2 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry3-traps 1.3.6.1.4.1.5528.30.100.17
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry3-triggered-trap 1.3.6.1.4.1.5528.30.100.17.2
Netbotz External Dry Contact 3 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext3 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry3-trap-clear 1.3.6.1.4.1.5528.30.100.17.3
Netbotz External Dry Contact 3 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext3 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry4-traps 1.3.6.1.4.1.5528.30.100.18
OBJECT IDENTIFIER    

netBotz-prd-bot-ext-dry4-triggered-trap 1.3.6.1.4.1.5528.30.100.18.2
Netbotz External Dry Contact 4 Triggered Trap. This trap indicates that the state of the dry contact sensor on Ext4 matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric  

netBotz-prd-bot-ext-dry4-trap-clear 1.3.6.1.4.1.5528.30.100.18.3
Netbotz External Dry Contact 4 Cleared Trap. The trap has been cleared because the state of the dry contact sensor on Ext4 no longer matches the alarm value.
TRAP-TYPE    
  netBotz-prd-bot-trap-index  
  netBotz-prd-bot-trap-address  
  netBotz-prd-bot-trap-oid  
  netBotz-prd-bot-trap-value  
  netBotz-prd-bot-trap-date  
  netBotz-ismetric