PANDATEL-FOBUS-MODEM-MIB

File: PANDATEL-FOBUS-MODEM-MIB.mib (7835 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
PANDATEL-MODEM-MIB

Imported symbols

enterprises DisplayString OBJECT-TYPE
mdmSpecifics device-id

Defined Objects

fobus 1.3.6.1.4.1.760.1.1.2.1.10.501
OBJECT IDENTIFIER    

fobusModemTable 1.3.6.1.4.1.760.1.1.2.1.10.501.1
This table contains information about all FOBUS units in all racks.
OBJECT-TYPE    
  SEQUENCE OF  
    FobusTableEntry

fobusTableEntry 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1
The index of the table.
OBJECT-TYPE    
  FobusTableEntry  

mdmRack 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.1
The index of the rack where the unit is installed.
OBJECT-TYPE    
  INTEGER  

mdmModem 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.2
This entry displays the slot number where the corresponding unit is installed in the rack.
OBJECT-TYPE    
  INTEGER  

mdmPosition 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.3
This entry displays the location of the corresponding unit: 'local' or 'remote'. The unit which is plugged into a managed rack is 'local', the counterpart is 'remote'.
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

mdmModemName 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.5
The verbal name of this unit.
OBJECT-TYPE    
  DisplayString  

mdmBackupStatus 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.11
The backup status of the unit. The available values depend on the generation of the unit.
OBJECT-TYPE    
  INTEGER other(1), inactive(2), active(3), not-available(4), available(5), disable(6)  


mdmOperationMode 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.66
This entry defines if data is transmitted via port 2 or port 3: 'forced-port2', 'forced-port3', 'automatic'.
OBJECT-TYPE    
  INTEGER other(1), forced-port2(3), forced-port3(4), automatic(5)  

mdmAlarmConditionPort1 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.110
The alarm trigger mode at port 1: 'disable', i.e. no alarm is triggered, or 'link-signal', i.e. an alarm is triggered if the link is down.
OBJECT-TYPE    
  INTEGER other(1), disable(2), link-signal(3)  

mdmAlarmConditionPort2 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.111
The alarm trigger mode at port 2: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. an alarm is triggered if the laser diode is defective, or 'no-link-signal-or-laser-fail', i.e. the link is down or the laser diode is defective.
OBJECT-TYPE    
  INTEGER other(1), disable(2), no-link-signal(3), laser-fail(4), no-link-signal-or-laser-fail(5)  

mdmAlarmConditionPort3 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.112
The alarm trigger mode at port 3: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. an alarm is triggered if the laser diode is defective, or 'no-link-signal-or-laser-fail', i.e. the link is down or the laser diode is defective.
OBJECT-TYPE    
  INTEGER other(1), disable(2), no-link-signal(3), laser-fail(4), no-link-signal-or-laser-fail(5)  

mdmTXLaserStatusPort2 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.121
This entry indicates if the laser diode at port 2 is transmitting data ('enable') or not ('disable').
OBJECT-TYPE    
  INTEGER other(1), disable(2), enable(3)  

mdmTXLaserStatusPort3 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.122
This entry indicates if the laser diode at port 3 is transmitting data ('enable') or not ('disable').
OBJECT-TYPE    
  INTEGER other(1), disable(2), enable(3)  

fobus-modem 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501
OBJECT IDENTIFIER    

Defined Objects

FobusTableEntry  
SEQUENCE    
  INTEGER as mdmRack  
  INTEGER as mdmModem  
  INTEGER as mdmPosition  
  DisplayString as mdmModemName  
  INTEGER as mdmBackupStatus  
  INTEGER as mdmActiveLink  
  INTEGER as mdmOperationMode  
  INTEGER as mdmAlarmConditionPort1  
  INTEGER as mdmAlarmConditionPort2  
  INTEGER as mdmAlarmConditionPort3  
  INTEGER as mdmTXLaserStatusPort2  
  INTEGER as mdmTXLaserStatusPort3