
| RFC1155-SMI | RFC1213-MIB | RFC-1212 |
| PANDATEL-MODEM-MIB |
| enterprises | Gauge | DisplayString |
| OBJECT-TYPE | mdmSpecifics | device-id |
| gmf | 1.3.6.1.4.1.760.1.1.2.1.10.202 | ||
| OBJECT IDENTIFIER | |||
| gmfModemTable | 1.3.6.1.4.1.760.1.1.2.1.10.202.1 | ||
| This table contains information about all GM-F converters in all racks. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| GmfTableEntry | |||
| gmfTableEntry | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1 | ||
| The index of the table. | |||
| OBJECT-TYPE | |||
| GmfTableEntry | |||
| mdmRack | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.1 | ||
| The index of the rack where the converter is installed. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| mdmModem | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.2 | ||
| This entry displays the slot number where the corresponding converter is installed in the rack. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| mdmPosition | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.3 | ||
| This entry displays the location of the corresponding converter: 'local' or 'remote'. The converter which is plugged into a managed rack is 'local', the counterpart is 'remote'. | |||
| OBJECT-TYPE | |||
| INTEGER | local(1), remote(2) | ||
| mdmModemName | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.5 | ||
| The verbal name of this converter. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| mdmInterfaceEmulationMode | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.6 | ||
| Interface mode of the unit: 'dte', 'dce', 'te' or 'nt'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), dte(2), dce(3), te(4), nt(5), unknown(99) | ||
| mdmModemProperty | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.7 | ||
| This entry displays the speed class of the GM-F: 'e1' or 't1'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), e1(2), t1(3), unknown(99) | ||
| mdmLineEmulationMode | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.8 | ||
| Line mode of the unit: 'te' or 'nt'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), te(4), nt(5), unknown(99) | ||
| mdmClockSystem | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.23 | ||
| The clock system of the link: 'dual' or 'single'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), dual(2), single(3) | ||
| mdmClockSource | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.24 | ||
| The clock source of the link: 'internal', 'external', or 'remote'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), internal(2), remote(3), external(4) | ||
| mdmDataRate | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.25 | ||
| The data rate at the interface in bits per seconds. The data rate at the remote counterpart changes simultaneously. A data rate of 2.048 Mbps (E1) automatically disables CRC4, sets mdmStartTimeslot to 'unframed', enables time slot 16, and disables remote access. A data rate of 1.984 Mbps (E1) automatically sets mdmStartTimeslot to 'timeslot-1', enables time slot 16 and sets mdmRemoteAccessMode to 'via timeslot 0 sa4-bit'. A data rate of 1.544 Mbps (T1) automatically sets mdmStartTimeslot to 'unframed' and disables remote access. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1) | ||
| mdmStartTimeslot | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.26 | ||
| This entry determines the start time slot for framing. Start time slot and data rate must match. A start time slot which is too high will be ignored. The remote unit's configuration changes simultaneously. | |||
| OBJECT-TYPE | |||
| INTEGER | timeslot-1(1), timeslot-2(2), timeslot-3(3), timeslot-4(4), timeslot-5(5), timeslot-6(6), timeslot-7(7), timeslot-8(8), timeslot-9(9), timeslot-10(10), timeslot-11(11), timeslot-12(12), timeslot-13(13), timeslot-14(14), timeslot-15(15), timeslot-16(16), timeslot-17(17), timeslot-18(18), timeslot-19(19), timeslot-20(20), timeslot-21(21), timeslot-22(22), timeslot-23(23), timeslot-24(24), timeslot-25(25), timeslot-26(26), timeslot-27(27), timeslot-28(28), timeslot-29(29), timeslot-30(30), timeslot-31(31), unframed(98), other(99), not-available(100) | ||
| mdmTimeslotSize | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.27 | ||
| This entry determines the size of the time slots: 'nx64k' or 'nx56k'. 'nx56k' is valid for T1 units only. The remote unit's configuration changes simultaneously. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), nx64k(2), nx56k(3), not-available(100) | ||
| mdmTimeslot16 | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.40 | ||
| This entry enables or disables time slot 16. If it is disabled, it will not be used for data transmission but for framing. Valid for E1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), disable(2), enable(3), not-available(100) | ||
| mdmCRC4Generation | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.41 | ||
| This entry enables or disables the generation of a CRC4 check sum. Valid for E1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), disable(2), enable(3), not-available(100) | ||
| mdmFramingMode | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.50 | ||
| The T1 framing mode: 'd4' or 'esf'. The remote unit's configuration changes simultaneously. Valid for T1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), d4(2), esf(3), not-available(100) | ||
| mdmCodingMode | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.51 | ||
| The T1 coding mode: 'ami' or 'b8zs'. The remote unit's configuration changes simultaneously. Valid for T1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), ami(2), b8zs(3), not-available(100) | ||
| mdmScrambler | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.63 | ||
| This entry enables or disables scrambling. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), disable(2), enable(3) | ||
| mdmRemoteAccessMode | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.64 | ||
| The remote access mode: 'disable', 'via-next-free-timeslot', 'via-timeslot-0-Sa4-bit', or 'via-unframed-line'. The value 'via-next-free-timeslot' means that one time slot higher than the last data time slot is used for remote access. The value 'via-timeslot-0-Sa4-bit' means that the sa4-bit in time slot 0 is used for remote access (for E1 units only). The value 'via-unframed-line' is valied for data rates of 2048 Kbps (E1) or 1544 Kbps (T1) only. With a data rate of 1536 Kbps (T1). remote management is not available. The remote unit's configuration changes simultaneously. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), disable(2), via-next-free-timeslot(3), via-timeslot-0-Sa4-bit(4), via-unframed-line(6) | ||
| mdmForcedRemoteAccess | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.65 | ||
| Valid if 'mdmRemoteAccessMode' is set to 'via-unframed-line'. Activation of remote management: 'on' or 'off'. Status 'on' enables management of remote unit. During this process the link is restricted to management data. The transmission of user data is interrupted. Status 'off' disables management of remote unit. The link transmits user data. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2), not-available(100) | ||
| mdmTDPhaseLocking | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.67 | ||
| This entry defines the data phase locking for I/F data: 'positive-clock-slope' or 'negative-clock-slope'. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), positive-clock-slope(2), negative-clock-slope(3), unknown(99), not-available(100) | ||
| mdmLineBuiltOut | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.68 | ||
| The T1 transmission mode of the unit. Valid for T1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), dsx-1-0to133-ft(3), dsx-1-133to266-ft(4), dsx-1-266to399-ft(5), dsx-1-399to533-ft(6), dsx-1-533to655-ft(7), csu-0db(8), csu-7db5(9), csu-15db(10), csu-22db5(11), not-available(100) | ||
| mdmCRC6Test | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.100 | ||
| This entry enables the execution of a CRC6 test. Write requests with values other than 'start' or 'stop' will be rejected. Valid for T1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), start(3), stop(4), not-available(100) | ||
| mdmCRC6Status | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.101 | ||
| This entry indicates the status of the CRC6 test. Valid for T1 units only. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), never-started(2), running(5), stopped(6), start-failed(7), not-available(100) | ||
| mdmCRC6Error | 1.3.6.1.4.1.760.1.1.2.1.10.202.1.1.102 | ||
| This entry indicates the number of errors detected during the last 60 seconds. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| gmf-modem | 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.202 | ||
| OBJECT IDENTIFIER | |||
| GmfTableEntry | |||
| SEQUENCE | |||
| INTEGER as mdmRack | |||
| INTEGER as mdmModem | |||
| INTEGER as mdmPosition | |||
| DisplayString as mdmModemName | |||
| INTEGER as mdmInterfaceEmulationMode | |||
| INTEGER as mdmModemProperty | |||
| INTEGER as mdmLineEmulationMode | |||
| INTEGER as mdmClockSystem | |||
| INTEGER as mdmClockSource | |||
| INTEGER as mdmDataRate | |||
| INTEGER as mdmStartTimeslot | |||
| INTEGER as mdmTimeslotSize | |||
| INTEGER as mdmTimeslot16 | |||
| INTEGER as mdmCRC4Generation | |||
| INTEGER as mdmFramingMode | |||
| INTEGER as mdmCodingMode | |||
| INTEGER as mdmScrambler | |||
| INTEGER as mdmRemoteAccessMode | |||
| INTEGER as mdmForcedRemoteAccess | |||
| INTEGER as mdmTDPhaseLocking | |||
| INTEGER as mdmLineBuiltOut | |||
| INTEGER as mdmCRC6Test | |||
| INTEGER as mdmCRC6Status | |||
| Gauge as mdmCRC6Error | |||