RAD-ARC-MIB

File: RAD-ARC-MIB.mib (238366 bytes)

Imported modules

RFC1155-SMI IF-MIB RFC-1212
RFC-1215 RAD-MIB SNMPv2-TC
ATM-MIB SNMPv2-SMI SNMP-FRAMEWORK-MIB

Imported symbols

IpAddress ifIndex InterfaceIndex
ifAlias OBJECT-TYPE TRAP-TYPE
radAtm agnLed agnIndication
atmConfIfInputRate atmConfIfOutputRate DisplayString
RowStatus DateAndTime atmVplVpi
atmVclVpi atmVclVci NOTIFICATION-TYPE
Counter32 Gauge32 Integer32
SnmpAdminString atmInterfaceAlarmStatus alarmSeverity
alarmState

Defined Objects

atmAceSystemTrap 1.3.6.1.4.1.164.6.1.12.0.6
This trap alerts of major problems in the device.
NOTIFICATION-TYPE    
  atmNteEventType  
  agnLed  
  alarmSeverity  

atmAceAlarmForwardingTrap 1.3.6.1.4.1.164.6.1.12.0.7
This trap is sent upon starting or stopping Alarm Forwarding Mechanism.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  

atmAceAlarmLOS 1.3.6.1.4.1.164.6.1.12.0.16
This trap indicates Loss Of Signal.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLOF 1.3.6.1.4.1.164.6.1.12.0.17
This trap indicates Loss Of Frame.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLCD 1.3.6.1.4.1.164.6.1.12.0.18
This trap indicates Loss of Cell Delineation.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmSLM 1.3.6.1.4.1.164.6.1.12.0.19
This trap indicates Signal Line Mismatch.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLOP 1.3.6.1.4.1.164.6.1.12.0.20
This trap indicates Loss of Pointer.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLineAIS 1.3.6.1.4.1.164.6.1.12.0.21
This trap indicates Line AIS.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPathAIS 1.3.6.1.4.1.164.6.1.12.0.22
This trap indicates Path AIS.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLineRDI 1.3.6.1.4.1.164.6.1.12.0.23
This trap indicates Line RDI.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPathRDI 1.3.6.1.4.1.164.6.1.12.0.24
This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmSectionBIP 1.3.6.1.4.1.164.6.1.12.0.25
This trap indicates Section Bit Interleave Parity.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLineBIP 1.3.6.1.4.1.164.6.1.12.0.26
This trap indicates Line Bit Interleave Parity.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPathBIP 1.3.6.1.4.1.164.6.1.12.0.27
This trap indicates Path Bit Interleave Parity.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmLineFEBE 1.3.6.1.4.1.164.6.1.12.0.28
This trap indicates Line Far End Block Error.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPathFEBE 1.3.6.1.4.1.164.6.1.12.0.29
This trap indicates Path Far End Block Error.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPlcpLOF 1.3.6.1.4.1.164.6.1.12.0.30
This trap indicates T3 PLCP Loss Of Frame.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPlcpYELLOW 1.3.6.1.4.1.164.6.1.12.0.31
This trap indicates T3 Plcp Yellow.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPlcpBIP 1.3.6.1.4.1.164.6.1.12.0.32
This trap indicates T3 Plcp Bit Interleave Parity.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPlcpFEBE 1.3.6.1.4.1.164.6.1.12.0.33
This trap indicates T3 Plcp Far End Block Error.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmPlcpP1P2 1.3.6.1.4.1.164.6.1.12.0.34
This trap indicates T3 Plcp Parity errors in P1/P2 bytes.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmUAS 1.3.6.1.4.1.164.6.1.12.0.35
This trap is sent upon UAS start or end per port.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmCluster 1.3.6.1.4.1.164.6.1.12.0.36
This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  atmNteAlarmType  
  atmNteLevel  

atmAceHwFailure 1.3.6.1.4.1.164.6.1.12.0.37
This trap is sent upon HW failure per port.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceUnavailableBwTrap 1.3.6.1.4.1.164.6.1.12.0.38
This trap is sent when Bandwidth allocation is > max possible value for the installed card. For ACE2002 this trap will be sent for the following cases: Card insertion - if the total Input and/or Output Bandwidth is over allocated, then the specific card rate will be set to 0 and this trap will be sent with the Input/Output rates values. Upgrade from former version - when an over allocated Bandwidth is detected, this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF.
NOTIFICATION-TYPE    
  alarmSeverity  
  ifAlias  
  atmConfIfInputRate  
  atmConfIfOutputRate  

atmAceAlarmVpContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.40
This trap indicates Loss of Continuity Check on a VP Connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpAISReception 1.3.6.1.4.1.164.6.1.12.0.41
This trap indicates AIS Reception on a VP Connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpRDIReception 1.3.6.1.4.1.164.6.1.12.0.42
This trap indicates RDI Reception on a VP Connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpErroredCells 1.3.6.1.4.1.164.6.1.12.0.43
This trap indicates Errored Cells on a VP Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpLostCells 1.3.6.1.4.1.164.6.1.12.0.44
This trap indicates Lost Cells on a VP Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.45
This trap indicates Misinserted Cells on a VP Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpUAS 1.3.6.1.4.1.164.6.1.12.0.46
This trap is sent upon UAS start or end per VP.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpLoopback 1.3.6.1.4.1.164.6.1.12.0.47
This trap is sent upon OAM LoopBack fail status per VP.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVpGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.48
This trap indicates GCRA violation on a VP Connection reported by UPC device.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.56
This trap indicates Loss of Continuity Check on a VC Connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcAISReception 1.3.6.1.4.1.164.6.1.12.0.57
This trap indicates AIS Reception on a VC.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcRDIReception 1.3.6.1.4.1.164.6.1.12.0.58
This trap indicates RDI Reception on a VC Connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcErroredCells 1.3.6.1.4.1.164.6.1.12.0.59
This trap indicates Errored Cells on a VC Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcLostCells 1.3.6.1.4.1.164.6.1.12.0.60
This trap indicates Lost Cells on a VC Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.61
This trap indicates Misinserted Cells on a VC Connection reported by PM.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcUnexpectedCell 1.3.6.1.4.1.164.6.1.12.0.62
This trap indicates an unexpected cell from user or network port.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcUAS 1.3.6.1.4.1.164.6.1.12.0.63
This trap is sent upon UAS start or end per VC.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcLoopback 1.3.6.1.4.1.164.6.1.12.0.64
This trap is sent upon OAM LoopBack fail status per VC.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmAceAlarmVcGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.65
This trap indicates GCRA violation on a VC Connection reported by UPC device.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

atmGen 1.3.6.1.4.1.164.12.2
OBJECT IDENTIFIER    

atmPerfHistory 1.3.6.1.4.1.164.12.2.1
OBJECT IDENTIFIER    

atmIfPerformance 1.3.6.1.4.1.164.12.2.1.1
OBJECT IDENTIFIER    

atmIfDataTable 1.3.6.1.4.1.164.12.2.1.1.1
The ATM interface Data table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfDataEntry

atmIfDataEntry 1.3.6.1.4.1.164.12.2.1.1.1.1
An entry in the ATM interface Data table.
OBJECT-TYPE    
  AtmIfDataEntry  

atmIfTimeElapsed 1.3.6.1.4.1.164.12.2.1.1.1.1.1
The number of seconds that have elapsed since the beginning of the near end current error- measurement period.
OBJECT-TYPE    
  Integer32 0..899  

atmIfValidIntervals 1.3.6.1.4.1.164.12.2.1.1.1.1.2
The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

atmIfCurrentTable 1.3.6.1.4.1.164.12.2.1.1.2
The ATM interface Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfCurrentEntry

atmIfCurrentEntry 1.3.6.1.4.1.164.12.2.1.1.2.1
An entry in the ATM interface Current table.
OBJECT-TYPE    
  AtmIfCurrentEntry  

atmIfCurrentTxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.1
The counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmIfCurrentRxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.2
The counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmIfCurrentCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.3
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmIfCurrentUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.4
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmIfCurrentHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.2.1.5
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmIfIntervalTable 1.3.6.1.4.1.164.12.2.1.1.3
The ATM interface Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfIntervalEntry

atmIfIntervalEntry 1.3.6.1.4.1.164.12.2.1.1.3.1
An entry in the ATM interface Interval table.
OBJECT-TYPE    
  AtmIfIntervalEntry  

atmIfIntervalNumber 1.3.6.1.4.1.164.12.2.1.1.3.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmIfIntervalTxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.2
The counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmIfIntervalRxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.3
The counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmIfIntervalCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.4
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmIfIntervalUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.5
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmIfIntervalHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.3.1.6
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

aal5VccXTable 1.3.6.1.4.1.164.12.2.1.1.4
OBJECT IDENTIFIER    

atmPvcPerformance 1.3.6.1.4.1.164.12.2.1.2
OBJECT IDENTIFIER    

atmVpPerformance 1.3.6.1.4.1.164.12.2.1.2.1
OBJECT IDENTIFIER    

atmVpCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.1
The ATM VP Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCurrentEntry

atmVpCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.1.1
An entry in the ATM VP Current table.
OBJECT-TYPE    
  AtmVpCurrentEntry  

atmVpCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.1.1.1
The VPI of the VPL.
OBJECT-TYPE    
  Integer32  

atmVpCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.1.1.2
The counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.1.1.3
The counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.4
The counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.5
The counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.6
The counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.7
The counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.8
The counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.9
The counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.1.1.10
The counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.11
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.1.1.12
The counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.1.1.1.13
Amount of cells dropped in the current 15 minute interval of the VP connection.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.14
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.15
The total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.16
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.17
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.18
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.19
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second).
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.20
The average traffic rate during the last interval of the VP connection.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.21
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second).
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.22
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.23
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.24
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.2
The ATM VP Current table for Performance Management.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMCurrentEntry

atmVpPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.2.1
An entry in the ATM VP Current table for Performance Management.
OBJECT-TYPE    
  AtmVpPMCurrentEntry  

atmVpPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.2.1.1
The VPI of the VPL.
OBJECT-TYPE    
  Integer32  

atmVpPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.1.2.1.2
The direction of performance management.
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.3
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.4
The counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.5
The counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.6
The counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.7
The counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.8
The counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.9
The counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.10
The counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.11
The counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.12
The counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.13
The counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.2.1.14
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.15
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.16
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.3
The ATM Vp Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpIntervalEntry

atmVpIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.3.1
An entry in the ATM Vp Interval table.
OBJECT-TYPE    
  AtmVpIntervalEntry  

atmVpIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.3.1.1
The VPI of the VPL.
OBJECT-TYPE    
  Integer32  

atmVpIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.3.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmVpIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.3.1.3
The counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.3.1.4
The counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.5
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.6
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.7
The counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.8
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.9
The counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.10
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.3.1.11
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.12
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.3.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.1.3.1.14
Amount of cells dropped in the 15 minute interval of the VP connection.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.20
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.21
The average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.22
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.4
The ATM Vp Interval table for Performance Management.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMIntervalEntry

atmVpPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.4.1
An entry in the ATM Vp Interval table for Performance Management.
OBJECT-TYPE    
  AtmVpPMIntervalEntry  

atmVpPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.4.1.1
The VPI of the VPL.
OBJECT-TYPE    
  Integer32  

atmVpPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.1.4.1.2
The direction of performance management.
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.4.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmVpPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.7
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.8
The counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.9
The counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.10
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.11
The counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.12
The counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.13
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.14
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.4.1.15
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.5
The VP QoS table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpQoSEntry

atmVpQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.5.1
.
OBJECT-TYPE    
  AtmVpQoSEntry  

atmVpQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.5.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.1.5.1.2
Elapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received.
OBJECT-TYPE    
  Integer32  

atmVpQoSUAS 1.3.6.1.4.1.164.12.2.1.2.1.5.1.3
Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef).
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.6
The PM VP QoS table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMQoSEntry

atmVpPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.6.1
.
OBJECT-TYPE    
  AtmVpPMQoSEntry  

atmVpPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.1.6.1.1
The direction of performance management.
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.6.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.3
Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.1.6.1.4
Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.5
Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
OBJECT-TYPE    
  Gauge32  

atmVpShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.1.7
The ATM VP shaper statistics table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpShaperStatEntry

atmVpShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.1.7.1
An entry in the ATM VP shaper statistics table.
OBJECT-TYPE    
  AtmVpShaperStatEntry  

atmVpShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.1.7.1.1
The number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
OBJECT-TYPE    
  Counter32  

atmVpShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
OBJECT-TYPE    
  Integer32  

atmVpShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.3
The Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits.
OBJECT-TYPE    
  Integer32  

atmVpShaperLevel 1.3.6.1.4.1.164.12.2.1.2.1.7.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC.
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVpShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.5
The number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only.
OBJECT-TYPE    
  Counter32  

atmVpShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only.
OBJECT-TYPE    
  Counter32  

atmVcPerformance 1.3.6.1.4.1.164.12.2.1.2.2
OBJECT IDENTIFIER    

atmVcCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.1
The ATM VC Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCurrentEntry

atmVcCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.1.1
An entry in the ATM VC Current table.
OBJECT-TYPE    
  AtmVcCurrentEntry  

atmVcCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.1.1.1
The VPI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.1.1.2
The VCI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.1.1.3
The counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.1.1.4
The counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.5
The counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.6
The counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.7
The counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.8
The counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.9
The counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.10
The counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.1.1.11
The counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.12
The counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.1.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.2.1.1.14
Amount of cells dropped in the current 15 minute interval of the VC connection.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.20
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second).
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.21
The average traffic rate during the last interval of the VC connection.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.22
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second).
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.2
The ATM VC Current table for Performance Management.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMCurrentEntry

atmVcPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.2.1
An entry in the ATM VC Current table for Performance Management.
OBJECT-TYPE    
  AtmVcPMCurrentEntry  

atmVcPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.2.1.1
The VPI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.2.1.2
The VCI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.2.2.1.3
The direction of Performance Management.
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.7
The counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.8
The counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.9
The counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.10
The counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.11
The counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.12
The counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.13
The counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.14
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.2.1.15
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVcIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.3
The ATM Vc Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcIntervalEntry

atmVcIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.3.1
An entry in the ATM Vc Interval table.
OBJECT-TYPE    
  AtmVcIntervalEntry  

atmVcIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.3.1.1
The VPI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.3.1.2
The VCI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.3.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmVcIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.3.1.4
The counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.3.1.5
The counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.6
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.7
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.8
The counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.9
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.10
The counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.11
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.3.1.12
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.13
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.3.1.14
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.2.3.1.15
Amount of cells dropped in the 15 minute interval of the VC connection.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.16
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.17
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.18
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.19
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.20
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.21
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.22
The average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.23
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.24
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.25
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.26
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.4
The ATM Vc Interval table for Performance Management.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMIntervalEntry

atmVcPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.4.1
An entry in the ATM Vc Interval table for Performance Management.
OBJECT-TYPE    
  AtmVcPMIntervalEntry  

atmVcPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.4.1.1
The VPI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.4.1.2
The VCI of the VCL.
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.2.4.1.3
The direction of Performance Management.
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.4.1.4
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmVcPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.5
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.6
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.7
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.8
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.9
The counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.10
The counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.11
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.12
The counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.13
The counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.14
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.15
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.4.1.16
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.17
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.18
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmCESAAL1StatsTable 1.3.6.1.4.1.164.12.2.1.2.2.5
This table shows statistics of the structured Circuit-Emulation connections.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmCESAAL1StatsEntry

atmCESAAL1StatsEntry 1.3.6.1.4.1.164.12.2.1.2.2.5.1
defines an entry in the atmCESAAL1StatsTable
OBJECT-TYPE    
  AtmCESAAL1StatsEntry  

atmCESAAL1SeqErrors 1.3.6.1.4.1.164.12.2.1.2.2.5.1.1
number of cells discarded due to wrong sequence number
OBJECT-TYPE    
  Counter32  

atmCESAAL1HdrErrors 1.3.6.1.4.1.164.12.2.1.2.2.5.1.2
number of cells discarded due to bad AAL1 header error. this include correctable and uncorrectable CRC, plus bad parity.
OBJECT-TYPE    
  Counter32  

atmCESAAL1PointerReframes 1.3.6.1.4.1.164.12.2.1.2.2.5.1.3
number of events in which the AAL1 reassembler found that an SDT pointer isn't where it is expected, and the pointer must be reacquired.
OBJECT-TYPE    
  Counter32  

atmCESAAL1BufUnderflows 1.3.6.1.4.1.164.12.2.1.2.2.5.1.4
number of buffer underflows events.
OBJECT-TYPE    
  Counter32  

atmCESAAL1BufOverflows 1.3.6.1.4.1.164.12.2.1.2.2.5.1.5
number of buffer overflows events.
OBJECT-TYPE    
  Counter32  

atmVcQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.6
The ATM VP QoS table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcQoSEntry

atmVcQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.6.1
An entry in the ATM VP table.
OBJECT-TYPE    
  AtmVcQoSEntry  

atmVcQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.6.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.2.6.1.2
Elapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received.
OBJECT-TYPE    
  Integer32  

atmVcQoSUAS 1.3.6.1.4.1.164.12.2.1.2.2.6.1.3
Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef).
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.7
The PM VC QoS table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMQoSEntry

atmVcPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.7.1
An entry in the VC PM QoS table.
OBJECT-TYPE    
  AtmVcPMQoSEntry  

atmVcPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.2.7.1.1
The direction of performance management.
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.7.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.3
Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.2.7.1.4
Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.5
Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
OBJECT-TYPE    
  Gauge32  

atmVcShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.2.8
The ATM VC shaper statistics table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcShaperStatEntry

atmVcShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.2.8.1
An entry in the ATM VC shaper statistics table.
OBJECT-TYPE    
  AtmVcShaperStatEntry  

atmVcShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.2.8.1.1
The number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
OBJECT-TYPE    
  Counter32  

atmVcShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
OBJECT-TYPE    
  Integer32  

atmVcShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.3
The Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits.
OBJECT-TYPE    
  Integer32  

atmVcShaperLevel 1.3.6.1.4.1.164.12.2.1.2.2.8.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC.
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVcShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.5
The number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only.
OBJECT-TYPE    
  Counter32  

atmVcShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only.
OBJECT-TYPE    
  Counter32  

atmIntervalDateTable 1.3.6.1.4.1.164.12.2.1.3
The agent will keep in this group the date & time corresponding to each interval.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIntervalDateEntry

atmIntervalDateEntry 1.3.6.1.4.1.164.12.2.1.3.1
The date & time for the given interval.
OBJECT-TYPE    
  AtmIntervalDateEntry  

atmIntervalDateInterval 1.3.6.1.4.1.164.12.2.1.3.1.1
The interval number defining this entry.
OBJECT-TYPE    
  Integer32 1..96  

atmIntervalDateDate 1.3.6.1.4.1.164.12.2.1.3.1.2
The date corresponding to this interval.
OBJECT-TYPE    
  DisplayString  

atmIntervalDateTime 1.3.6.1.4.1.164.12.2.1.3.1.3
The time corresponding to this interval.
OBJECT-TYPE    
  DisplayString  

atmGenSystem 1.3.6.1.4.1.164.12.2.2
OBJECT IDENTIFIER    

atmGenSysGen 1.3.6.1.4.1.164.12.2.2.1
OBJECT IDENTIFIER    

atmGenSysSelfTestTable 1.3.6.1.4.1.164.12.2.2.1.1
A table containing the results of the initial testing of the device.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysSelfTestEntry

atmGenSysSelfTestEntry 1.3.6.1.4.1.164.12.2.2.1.1.1
An entry in table.
OBJECT-TYPE    
  AtmGenSysSelfTestEntry  

atmGenSysSelfTestIndex 1.3.6.1.4.1.164.12.2.2.1.1.1.1
A running index for the table.
OBJECT-TYPE    
  Integer32  

atmGenSysSelfTestResult 1.3.6.1.4.1.164.12.2.2.1.1.1.2
The results of the initial testing of the device.
OBJECT-TYPE    
  DisplayString  

atmGenSysLogClearAll 1.3.6.1.4.1.164.12.2.2.1.2
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmGenSysLogTable 1.3.6.1.4.1.164.12.2.2.1.3
A copy of the log buffer.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysLogEntry

atmGenSysLogEntry 1.3.6.1.4.1.164.12.2.2.1.3.1
An entry in table.
OBJECT-TYPE    
  AtmGenSysLogEntry  

atmGenSysLogIndex 1.3.6.1.4.1.164.12.2.2.1.3.1.1
The index of the log buffer.
OBJECT-TYPE    
  Integer32 1..2048  

atmGenSysLogMessage 1.3.6.1.4.1.164.12.2.2.1.3.1.2
The log buffer entry message text.
OBJECT-TYPE    
  DisplayString SIZE(80)  

atmGenSysSetDefaultConfg 1.3.6.1.4.1.164.12.2.2.1.4
When set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmGenSysCxRefTable 1.3.6.1.4.1.164.12.2.2.1.5
A Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysCxRefEntry

atmGenSysCxRefEntry 1.3.6.1.4.1.164.12.2.2.1.5.1
The entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)
OBJECT-TYPE    
  AtmGenSysCxRefEntry  

atmGenSysCxRefIndex 1.3.6.1.4.1.164.12.2.2.1.5.1.1
The index specifies an entry in the table of the object.
OBJECT-TYPE    
  Integer32  

atmGenSysCxRefCounter 1.3.6.1.4.1.164.12.2.2.1.5.1.2
The counter counts the number of references that have been made to the object .
OBJECT-TYPE    
  Gauge32  

atmAceStatusChange 1.3.6.1.4.1.164.12.3.0.1
The trap is sent every time there is a change in the state of one of the LEDs.
NOTIFICATION-TYPE    
  agnLed  
  agnIndication  

atmAceAlarmTrap 1.3.6.1.4.1.164.12.3.0.2
The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval.
NOTIFICATION-TYPE    
  atmInterfaceAlarmStatus  

atmAceModuleChangeTrap 1.3.6.1.4.1.164.12.3.0.3
The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out.
NOTIFICATION-TYPE    
  ifIndex  

atmAceRedundancyTrap 1.3.6.1.4.1.164.12.3.0.4
The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link.
NOTIFICATION-TYPE    
  ifIndex  

atmNteSys 1.3.6.1.4.1.164.12.3.1
OBJECT IDENTIFIER    

atmNteSysConfig 1.3.6.1.4.1.164.12.3.1.1
OBJECT IDENTIFIER    

atmNteManagerTable 1.3.6.1.4.1.164.12.3.1.1.1
The Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The PVCs must be from the four allowed. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteManagerEntry

atmNteManagerEntry 1.3.6.1.4.1.164.12.3.1.1.1.1
A single manager and the PVC for receiving traps.
OBJECT-TYPE    
  AtmNteManagerEntry  

atmNteManagerIP 1.3.6.1.4.1.164.12.3.1.1.1.1.1
The IP address of the NMS.
OBJECT-TYPE    
  IpAddress  

atmNteManagerPvc 1.3.6.1.4.1.164.12.3.1.1.1.1.2
A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below.
OBJECT-TYPE    
  Integer32  

atmNteManagerIfIndex 1.3.6.1.4.1.164.12.3.1.1.1.1.3
The ATM interface index of the management port.
OBJECT-TYPE    
  Integer32  

atmNteManagerVpi 1.3.6.1.4.1.164.12.3.1.1.1.1.4
The VPI of the management VCL. Default: 0.
OBJECT-TYPE    
  Integer32  

atmNteManagerVci 1.3.6.1.4.1.164.12.3.1.1.1.1.5
The VCI of the management VCL. Defaults: 32,33,34,35.
OBJECT-TYPE    
  Integer32  

atmNteManagerTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.6
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
OBJECT-TYPE    
  Integer32  

atmNteManagerRowStatus 1.3.6.1.4.1.164.12.3.1.1.1.1.7
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

atmNteManagerNextHop 1.3.6.1.4.1.164.12.3.1.1.1.1.8
This parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route.
OBJECT-TYPE    
  IpAddress  

atmNteManagerVlanSupport 1.3.6.1.4.1.164.12.3.1.1.1.1.9
VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteManagerVlanIdentifier 1.3.6.1.4.1.164.12.3.1.1.1.1.10
VLAN ID. Range is 0..4095.
OBJECT-TYPE    
  Integer32  

atmNteManagerVlanFramePriority 1.3.6.1.4.1.164.12.3.1.1.1.1.11
VLAN Frame priority.Range is 0..7.
OBJECT-TYPE    
  Integer32  

atmNteManagerAlarmTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.12
The value of this object determines the alarm traps that the agent should mask and not send to this NMS. The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. More details on the masked traps exist in the product specification. For products that do not mask specific traps, the value of the bits will be 0.
OBJECT-TYPE    
  OCTET STRING  

atmNteManagerConfigPorts 1.3.6.1.4.1.164.12.3.1.1.1.1.13
This variable defines from which port/s this manager can configure the device. For IPmux 11 the value of this variable will be according to the ports combination: Network =1 User1=2 User2=4 (For Example: All ports = 7).
OBJECT-TYPE    
  Integer32  

atmNteUPLTCR 1.3.6.1.4.1.164.12.3.1.1.2
The Unacceptable ES Limit threshold for Performance Management.
OBJECT-TYPE    
  Integer32  

atmNteDPLTCR 1.3.6.1.4.1.164.12.3.1.1.3
The Degraded ES Limit threshold for Performance Management.
OBJECT-TYPE    
  Integer32  

atmNteSysLogClearAll 1.3.6.1.4.1.164.12.3.1.1.4
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmNteUSESLTCR 1.3.6.1.4.1.164.12.3.1.1.5
The Unacceptable SES Limit threshold for Performance Management.
OBJECT-TYPE    
  Integer32  

atmNteDSESLTCR 1.3.6.1.4.1.164.12.3.1.1.6
The Degraded ES Limit threshold for Performance Management.
OBJECT-TYPE    
  Integer32  

atmNteProtection 1.3.6.1.4.1.164.12.3.1.1.8
OBJECT IDENTIFIER    

atmNteProtectionMode 1.3.6.1.4.1.164.12.3.1.1.8.1
Protection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection.
OBJECT-TYPE    
  INTEGER off(1), mspOn(2), pathOn(3), mspUniOn(4), mspOneToN(5)  



atmNteConfOam 1.3.6.1.4.1.164.12.3.1.1.9
OBJECT IDENTIFIER    

atmNteConfOamSupport 1.3.6.1.4.1.164.12.3.1.1.9.1
OAM support mode, which determines the device location in a segment wise.
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3), vpEndToEndVcSegment(4)  

atmNteConfOamTransmission 1.3.6.1.4.1.164.12.3.1.1.9.2
OBJECT IDENTIFIER    

atmNteConfOamAIS 1.3.6.1.4.1.164.12.3.1.1.9.2.1
Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamRDI 1.3.6.1.4.1.164.12.3.1.1.9.2.2
Defines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk.
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamAddressing 1.3.6.1.4.1.164.12.3.1.1.9.3
OBJECT IDENTIFIER    

atmNteConfLoopbackAddMode 1.3.6.1.4.1.164.12.3.1.1.9.3.1
Loopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfLoopbackSourceAdd 1.3.6.1.4.1.164.12.3.1.1.9.3.2
Loopback source address. This field is relevant when atmNteConfOamAddMode is on.
OBJECT-TYPE    
  OCTET STRING SIZE(2..20)  

atmNteConfOamIfTable 1.3.6.1.4.1.164.12.3.1.1.9.4
OAM support per ATM interface.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfOamIfEntry

atmNteConfOamIfEntry 1.3.6.1.4.1.164.12.3.1.1.9.4.1
.
OBJECT-TYPE    
  AtmNteConfOamIfEntry  

atmNteConfOamIfAisRdi 1.3.6.1.4.1.164.12.3.1.1.9.4.1.1
This parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfCAC 1.3.6.1.4.1.164.12.3.1.1.10
OBJECT IDENTIFIER    

atmNteConfCACMode 1.3.6.1.4.1.164.12.3.1.1.10.1
CAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmNteHostIfTable 1.3.6.1.4.1.164.12.3.1.1.11
Host IP interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteHostIfEntry

atmNteHostIfEntry 1.3.6.1.4.1.164.12.3.1.1.11.1
.
OBJECT-TYPE    
  AtmNteHostIfEntry  

atmNteHostPvcIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.1
A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port.
OBJECT-TYPE    
  Integer32  

atmNteHostIP 1.3.6.1.4.1.164.12.3.1.1.11.1.2
The host interface IP address.
OBJECT-TYPE    
  IpAddress  

atmNteHostMask 1.3.6.1.4.1.164.12.3.1.1.11.1.3
The host interface subnet mask.
OBJECT-TYPE    
  IpAddress  

atmNteHostAtmIfIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.4
ATM interface index. Will be 1 for user port, and 2 for network port.
OBJECT-TYPE    
  Integer32  

atmNteHostVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.5
VPI of the PVC connected to that host interface.
OBJECT-TYPE    
  Integer32  

atmNteHostVci 1.3.6.1.4.1.164.12.3.1.1.11.1.6
VCI of the PVC connected to that host interface.
OBJECT-TYPE    
  Integer32  

atmNteHostRowStatus 1.3.6.1.4.1.164.12.3.1.1.11.1.7
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

atmNteHostRdnVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.8
The VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
OBJECT-TYPE    
  Integer32  

atmNteHostRdnVci 1.3.6.1.4.1.164.12.3.1.1.11.1.9
The VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultNextHop 1.3.6.1.4.1.164.12.3.1.1.11.1.10
The host interface Default Next Hop address. This address will be used as default next hop for every Bundle mapped to this Host.
OBJECT-TYPE    
  IpAddress  

atmNteHostVlanTagging 1.3.6.1.4.1.164.12.3.1.1.11.1.11
VLAN Tag support. no - No support to VLAN. yes - 4 VLAN bytes will be added to each frame connected to this Host.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteHostDefaultVlanID 1.3.6.1.4.1.164.12.3.1.1.11.1.12
Default VLAN ID of this Host.
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultVlanPriority 1.3.6.1.4.1.164.12.3.1.1.11.1.13
Default VLAN priority for this Host.
OBJECT-TYPE    
  Integer32  

atmNteShaperMode 1.3.6.1.4.1.164.12.3.1.1.12
Shaper Mode. vpInbandMng - Vcc within a Vp for management.
OBJECT-TYPE    
  INTEGER normal(1), group(2), aggregate(3), vpInbandMng(4)  

atmNteOutputRate 1.3.6.1.4.1.164.12.3.1.1.13
Aggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate.
OBJECT-TYPE    
  Integer32  

atmNteTosMode 1.3.6.1.4.1.164.12.3.1.1.14
TOS Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

atmNteTosMask 1.3.6.1.4.1.164.12.3.1.1.15
This parameter determines the seqence of bits that will be used for TOS. For ACE101 this parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

atmNteTosHighPriority 1.3.6.1.4.1.164.12.3.1.1.16
Priorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #).
OBJECT-TYPE    
  OCTET STRING SIZE(8)  

atmNtePlugAndPlayActivity 1.3.6.1.4.1.164.12.3.1.1.17
Activity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory.
OBJECT-TYPE    
  INTEGER disable(1), offline(2), online(3)  

atmNteSlotUsage 1.3.6.1.4.1.164.12.3.1.1.18
Applicable to ace2002. Slot 2 might be configured as user slot or as network slot.
OBJECT-TYPE    
  INTEGER notApplicable(1), user(2), network(3)  

atmNteConnectionsMaxNumber 1.3.6.1.4.1.164.12.3.1.1.19
The MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002.
OBJECT-TYPE    
  INTEGER notApplicable(1), max1024(2), max2048(3)  

atmNteDefaultVpi 1.3.6.1.4.1.164.12.3.1.1.20
Default Vpi for management.
OBJECT-TYPE    
  Integer32  

atmNteDefaultVci 1.3.6.1.4.1.164.12.3.1.1.21
Default Vci for management.
OBJECT-TYPE    
  Integer32  

atmNteReservedVpi 1.3.6.1.4.1.164.12.3.1.1.22
Internal use VPI, where shaperMode=vpInbandMng.
OBJECT-TYPE    
  Integer32 0..255  

atmNteRdnManagement 1.3.6.1.4.1.164.12.3.1.1.23
The redundancy management status.
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

atmNtePlugAndPlayIfIndex 1.3.6.1.4.1.164.12.3.1.1.24
The ifIndex of the Plug and Play VCC.
OBJECT-TYPE    
  InterfaceIndex  

atmNteLoopbackTimeout 1.3.6.1.4.1.164.12.3.1.1.25
The Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min.
OBJECT-TYPE    
  Integer32  

atmNteOamTable 1.3.6.1.4.1.164.12.3.1.1.26
This table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteOamEntry

atmNteOamEntry 1.3.6.1.4.1.164.12.3.1.1.26.1
An entry in the OAM table. Each entry in this table will indicate a special OAM.
OBJECT-TYPE    
  AtmNteOamEntry  

atmNteOamMode 1.3.6.1.4.1.164.12.3.1.1.26.1.1
The OAM cell path. endToEnd(1) - the entire path.
OBJECT-TYPE    
  INTEGER endToEnd(1)  

atmNteOamCellType 1.3.6.1.4.1.164.12.3.1.1.26.1.2
This object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell.
OBJECT-TYPE    
  INTEGER aisAndRdi(1), loopback(2)  

atmNteOamLevel 1.3.6.1.4.1.164.12.3.1.1.26.1.3
The level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level.
OBJECT-TYPE    
  INTEGER f5(3)  

atmNteOamEnable 1.3.6.1.4.1.164.12.3.1.1.26.1.4
This parameter determines if the specified OAM cells will be enabled.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmNteDefaultLoopbackThreshold 1.3.6.1.4.1.164.12.3.1.1.27
The Default OAM Loopback Failure Threshold value that will be used for configuration.
OBJECT-TYPE    
  Integer32  

atmNteMaxBurstSize 1.3.6.1.4.1.164.12.3.1.1.28
The Maximum allowed burst size (cell units). This object is applicable for each Physical port.
OBJECT-TYPE    
  Integer32  

atmNteGranularityFactor 1.3.6.1.4.1.164.12.3.1.1.29
This parameter affects the granularity of the guaranteed Rate (SCR+MCR) in spaced connection (cell/sec units). It is also defines the minimum guaranteed rate in spaced connection.
OBJECT-TYPE    
  Integer32  

atmNteTotalInputRate 1.3.6.1.4.1.164.12.3.1.1.30
This parameter indicates the total input rate of the device in cells/sec.
OBJECT-TYPE    
  Integer32  

atmNteTotalOutputRate 1.3.6.1.4.1.164.12.3.1.1.31
This parameter indicates the total output rate of the device in cells/sec.
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingTable 1.3.6.1.4.1.164.12.3.1.1.32
The Alarm Forwarding Mechanism will be operated for this table entries.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmAlarmForwardingEntry

atmAlarmForwardingEntry 1.3.6.1.4.1.164.12.3.1.1.32.1
Each entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
OBJECT-TYPE    
  AtmAlarmForwardingEntry  

atmAlarmForwardingFailPort 1.3.6.1.4.1.164.12.3.1.1.32.1.1
An Index of the port on which a fail occurs.
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingToPort 1.3.6.1.4.1.164.12.3.1.1.32.1.2
An Index of the port that will be affected upon the failure of the atmAlarmForwardingFailPort.
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingRowStatus 1.3.6.1.4.1.164.12.3.1.1.32.1.3
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

atmAlarmForwardingFailureLevel 1.3.6.1.4.1.164.12.3.1.1.32.1.4
This parameter determines the level of failure that will operate the Alarm Forwarding Mechanism.
OBJECT-TYPE    
  BITS physical(0), atm(1)  

atmAlarmForwardingRecoveryMode 1.3.6.1.4.1.164.12.3.1.1.32.1.5
This parameter determines the Recovery Mode. manual - The user should stop the RDI transmission by using the atmAlarmForwardingRecoveryCommand. automatic - The RDI transmission will be automatically stopped upon atmAlarmForwardingFailPort recovery.
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

atmAlarmForwardingRecoveryCommand 1.3.6.1.4.1.164.12.3.1.1.32.1.6
This parameter is a command. It is applicable when atmAlarmForwardingRecoveryMode = manual. on - Will stop the RDI transmission. After setting to 'On' the agent will set this parameter back to 'Off'.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmSysConfigCellTest 1.3.6.1.4.1.164.12.3.1.1.33
OBJECT IDENTIFIER    

atmSysConfigCellTestPort 1.3.6.1.4.1.164.12.3.1.1.33.1
An Index of the port on which the cell test will be sent.
OBJECT-TYPE    
  InterfaceIndex  

atmSysConfigCellTestVpi 1.3.6.1.4.1.164.12.3.1.1.33.2
The VPI on which the cell test will be sent.
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestVci 1.3.6.1.4.1.164.12.3.1.1.33.3
The VCI on which the cell test will be sent.
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestPti 1.3.6.1.4.1.164.12.3.1.1.33.4
The cell type.
OBJECT-TYPE    
  INTEGER user(1), oamSegment(2), oamEndToEnd(3)  

atmSysConfigCellTestClp 1.3.6.1.4.1.164.12.3.1.1.33.5
The type of the Cell.
OBJECT-TYPE    
  INTEGER clp0(1), clp1(2)  

atmSysConfigCellTestOamType 1.3.6.1.4.1.164.12.3.1.1.33.6
The OAM type of the Cell. This object is applicable if atmSysConfigCellTestPti = oamSegment/oamEndToEnd .
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), cc(3), lb(4)  

atmSysConfigCellTestPayload 1.3.6.1.4.1.164.12.3.1.1.33.7
The payload of the cell. For OAM cell the payload is set automatically to 6A.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

atmSysConfigCellTestQuantity 1.3.6.1.4.1.164.12.3.1.1.33.8
Quantity of cells to send.
OBJECT-TYPE    
  Integer32 1..10000  

atmSysConfigCellTestSendCmd 1.3.6.1.4.1.164.12.3.1.1.33.9
Setting the variable to send(3) perfroms cell test. The agent will immediately reset the variable to off(2).
OBJECT-TYPE    
  INTEGER off(2), send(3)  

atmVpCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.34
An extension to the ATM VP Cross Connect table (RFC2515 - atmVpCrossConnectTable).
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCrossConnectExtenEntry

atmVpCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.34.1
An entry in the table.
OBJECT-TYPE    
  AtmVpCrossConnectExtenEntry  

atmVpCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.34.1.1
The Connection's name.
OBJECT-TYPE    
  SnmpAdminString SIZE(1..64)  

atmVcCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.35
An extension to the ATM VC Cross Connect table (RFC2515 - atmVcCrossConnectTable).
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCrossConnectExtenEntry

atmVcCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.35.1
An entry in the table.
OBJECT-TYPE    
  AtmVcCrossConnectExtenEntry  

atmVcCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.35.1.1
The Connection's name.
OBJECT-TYPE    
  SnmpAdminString SIZE(1..64)  

atmNteSysInfo 1.3.6.1.4.1.164.12.3.1.2
OBJECT IDENTIFIER    

atmNteIdTable 1.3.6.1.4.1.164.12.3.1.2.1
The IDs of the cards and of the system.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteIdEntry

atmNteIdEntry 1.3.6.1.4.1.164.12.3.1.2.1.1
.
OBJECT-TYPE    
  AtmNteIdEntry  

atmNteIdIndex 1.3.6.1.4.1.164.12.3.1.2.1.1.1
An Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1. 13 - Fan2.
OBJECT-TYPE    
  Integer32  

atmNteUnitId 1.3.6.1.4.1.164.12.3.1.2.1.1.2
The ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed.
OBJECT-TYPE    
  Integer32  

atmNteUnitVersion 1.3.6.1.4.1.164.12.3.1.2.1.1.3
Hardware and Software version of the module.
OBJECT-TYPE    
  DisplayString  

atmNteCardType 1.3.6.1.4.1.164.12.3.1.2.1.1.4
The card type.
OBJECT-TYPE    
  INTEGER notApplicable(1), sc13mR155(2), st13sR155(3), st13lR155(4), utpR155(5), cxBncR155(6), e3(7), t3(8), e1(9), e1Ltu(10), fc13lR155(11), fc13lhR155(12), fc15lhR155(13), fc13lE3(14), fc13lhE3(15), fc15lhE3(16), fc13lT3(17), fc13lhT3(18), fc15lhT3(19), t1(20), eth(21), ethE1CesBnc(22), ethE1CesRj45(23), ethT1CesRj45(24), e1CesRj45(25), e1CesBnc(26), t1CesRj45(27), e14Ces(28), e14CesRj45(29), t14CesRj45(30), hdlc4port(31), hdlcE14CesBnc(32), hdlcE14CesRj45(33), hdlcT14CesRj45(34), e1Rj45(35), e1Bnc(36), ethE14CesBnc(37), ethE14CesRj45(38), ethT14CesRj45(39), hdlc1portHssi(40), hdlcHssiE14CesBnc(41), hdlcHssiE14CesRj45(42), hdlcHssiT14CesRj45(43), e14ImaRj45(44), e14ImaBnc(45), t14ImaRj45(46), ethE3CesBnc(47), ethT3CesBnc(48), smSf1R155(49), smSf2R155(50), sc13sR155(51), sc13lR155(52), utp25(53), sc13lhR155(54), sc15lhR155(55), sc13ljR155(56), sc13lhjR155(57), sc15lhjR155(58), e18Ces(59), e18CesRj45(60), t18CesRj45(61), sc13mR622(62), sc13lR622(73), sc13lhR622(74), sc15lhR622(75), fr4Port(76), t3j(77), fr1Port(78), hdlc1Port(79), sc13mR155D(80), sc13lR155D(81), fc13lR155D(82), st13lR155D(83), sc13lhR155D(84), fc13lhR155D(85), st13lhR155D(86), e18ImaBnc(87), e18ImaRj45(88), t18ImaRj45(89), lanUtpE(90), lanLc13lE(91), lanLc13mE(92), e14ImaRj45CfgMode(93), e14ImaBncCfgMode(94), t14ImaRj45CfgMode(95), sc13mR155R(96), sc13lR155R(97), fc13lR155R(98), st13lR155R(99), sc13lhR155R(100), fc13lhR155R(101), st13lhR155R(102), fEthUtpD(103), fEthSmD(104), fEthMmD(105), e14CesRj45Unbal(106), sc13mR155n(107), sc13lR155n(108), sc13lhR155n(109), sc15lhR155n(110), fc13lR155n(111), fc13lhR155n(112), fc15lhR155n(113), st13lR155n(114), lanUtp(115), lanLc13l(116), lanLc13m(117), e1FrHdlc(118), e1FrHdlcUnbal(119), t1FrHdlc(120), channelizedT3(121), fc15lhR155D(122), sc15lhR155D(123), smSf1R155D(124), smSf2R155D(125), smSf3R155D(126), fc15lhR155R(127), sc15lhR155R(128), smSf1R155R(129), smSf2R155R(130), smSf3R155R(131), st13lhR155n(132), smSf1R155n(133), smSf2R155n(134), smSf3R155n(135), t18CesNg(136), e18CesUnbalNg(137), e18CesBalNg(138), t14CesNg(139), e14CesUnbalNg(140), e14CesBalNg(141), t18ImaUniNg(142), e18ImaUniUnbalNg(143), e18ImaUniBalNg(144), t14ImaUniNg(145), e14ImaUniUnbalNg(146), e14ImaUniBalNg(147), t1Ces(148), e1CesUnbal(149), e1CesBal(150), empty(255)  

atmNteCardStatus 1.3.6.1.4.1.164.12.3.1.2.1.1.5
Status of the card in the selected slot. notActive - Connections are in NotReady state. No configuration is available for the card. The access to the card HW is blocked. This state is relevant for an extracted card, and for a case in which the card was deactivated. active - The module installed and functions. A card that in this state can be configured. inProgress - The status during proccessing of a command from atmNteCardCmd. empty - No information is valid for the selected slot. This status is relevant to a case in which the card configaration was deleted, or in case in which a slot was empty since the device startup.
OBJECT-TYPE    
  INTEGER notApplicable(1), notActive(2), active(3), inProgress(4), empty(5)  

atmNteCardCmd 1.3.6.1.4.1.164.12.3.1.2.1.1.6
Command on the card that is installed in the selected slot. The commands are applicable according to the value of atmNteCardStatus. See the specification document for details. deleteConfig - Deletes the card configuration. deactivate - All the connections state will be changed to NotReady. The card configuration will be blocked. activate - Does the same as done upon card insertion: Initiates the relevant parameters, activates the physical layer, ATM layer and logical layer.
OBJECT-TYPE    
  INTEGER notApplicable(1), deleteConfig(2), deactivate(3), activate(4)  

atmSysPSunits 1.3.6.1.4.1.164.12.3.1.2.2
The number of power supply units.
OBJECT-TYPE    
  Integer32  

atmSysPSunitsInUse 1.3.6.1.4.1.164.12.3.1.2.3
The main power supply in this unit.
OBJECT-TYPE    
  INTEGER ps1(2), ps2(3)  

atmSysFanUnits 1.3.6.1.4.1.164.12.3.1.2.4
The number of fan units.
OBJECT-TYPE    
  Integer32  

atmSysNetPrts 1.3.6.1.4.1.164.12.3.1.2.5
The number of network ports.
OBJECT-TYPE    
  Integer32  

atmSysNetPrtInUse 1.3.6.1.4.1.164.12.3.1.2.6
The network port in use.
OBJECT-TYPE    
  INTEGER trunk1(2), trunk2(3)  

atmNteBridgingMode 1.3.6.1.4.1.164.12.3.1.2.7
Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
OBJECT-TYPE    
  INTEGER accessOnly(1), accessAndSwitching(2)  

atmSysStats 1.3.6.1.4.1.164.12.3.1.2.8
OBJECT IDENTIFIER    

atmSysCurrentCdc 1.3.6.1.4.1.164.12.3.1.2.8.1
Seconds in which cells dropped was occured in the current 15 minutes interval.
OBJECT-TYPE    
  Gauge32  

atmSysIntervalTable 1.3.6.1.4.1.164.12.3.1.2.8.2
The system level Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSysIntervalEntry

atmSysIntervalEntry 1.3.6.1.4.1.164.12.3.1.2.8.2.1
.
OBJECT-TYPE    
  AtmSysIntervalEntry  

atmSysIntervalNumber 1.3.6.1.4.1.164.12.3.1.2.8.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

atmSysIntervalCdc 1.3.6.1.4.1.164.12.3.1.2.8.2.1.2
Seconds in which cells dropped was occured in 15 minutes interval.
OBJECT-TYPE    
  Gauge32  

atmNteEventType 1.3.6.1.4.1.164.12.3.1.2.9
This parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation.
OBJECT-TYPE    
  INTEGER ps1NotActive(3), ps1Active(4), ps2NotActive(5), ps2Active(6), heatAlarmOff(7), heatAlarmOn(8), inputAlarm1Off(9), inputAlarm1On(10), inputAlarm2Off(11), inputAlarm2On(12), inputAlarm3Off(13), inputAlarm3On(14), inputAlarm4Off(15), inputAlarm4On(16), fan1Ok(17), fan1Fail(18), fan2Ok(19), fan2Fail(20), invalidLogin(21), validLogin(22), powerFailure(23), writeToFlashFailure(24)  

atmNteIntervalMaxNumber 1.3.6.1.4.1.164.12.3.1.2.10
The MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002.
OBJECT-TYPE    
  Integer32 1..96  

atmNteAlarmType 1.3.6.1.4.1.164.12.3.1.2.11
This object specifies the type of the alarm.
OBJECT-TYPE    
  INTEGER notApplicable(1), ais(2), rdi(3), continuityLoss(4), loopback(5)  

atmNteLevel 1.3.6.1.4.1.164.12.3.1.2.12
This object specifies the ATM level.
OBJECT-TYPE    
  INTEGER vp(2), vc(3)  

atmNteConnectionsNumber 1.3.6.1.4.1.164.12.3.1.2.13
This object specifies a quantity of connections.
OBJECT-TYPE    
  Integer32  

atmNteTotalLb 1.3.6.1.4.1.164.12.3.1.2.14
This parameter counts the total number of end-points that were configured with Loopback (LB).
OBJECT-TYPE    
  Integer32  

atmNteTotalCc 1.3.6.1.4.1.164.12.3.1.2.15
This parameter counts the total number of end-points that were configured with Continuity Check (CC).
OBJECT-TYPE    
  Integer32  

atmNteTotalPm 1.3.6.1.4.1.164.12.3.1.2.16
This parameter counts the total number of end-points that were configured with PM.
OBJECT-TYPE    
  Integer32  

atmNteConfVcTable 1.3.6.1.4.1.164.12.3.2.1.4
The ATM VC configuration table. The table is an extension to the atmVclTable of RFC-2515.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfVcEntry

atmNteConfVcEntry 1.3.6.1.4.1.164.12.3.2.1.4.1
An entry in the ATM VC configuration table. ifIndex of the ATM layer.
OBJECT-TYPE    
  AtmNteConfVcEntry  

atmConfVcPolicing 1.3.6.1.4.1.164.12.3.2.1.4.1.1
Policing method desired for this VCL.
OBJECT-TYPE    
  INTEGER none(1), police(2), monitor(3), shaping(4), policingAndShaping(5), notApplicable(255)  

atmConfVcCCAdminStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.2
up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection.
OBJECT-TYPE    
  INTEGER up(2), down(3), source(4), sink(5), listenToActivationCells(6), originateActivationCells(7)  

atmConfVcLoopbackAdminStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.3
up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVcOamSupport value, since this parameter is for LB, while atmConfVcOamSupport is for any other OAM cells.
OBJECT-TYPE    
  INTEGER up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8)  

atmConfVcLoopbackSinkAddress 1.3.6.1.4.1.164.12.3.2.1.4.1.4
Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used.
OBJECT-TYPE    
  OCTET STRING SIZE(2..20)  

atmConfVcCongestionControl 1.3.6.1.4.1.164.12.3.2.1.4.1.5
Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI. For ace2002: 1 - Packet Discard.
OBJECT-TYPE    
  OCTET STRING  

atmConfVcCCDirection 1.3.6.1.4.1.164.12.3.2.1.4.1.6
both(2) - Agent sends OAM CC cells and checks received OAM CC cells. none(3) - Agent does not send and does not check received OAM CC cells. source(4)- Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells.
OBJECT-TYPE    
  INTEGER both(2), none(3), source(4), sink(5)  

atmConfVcCreationTime 1.3.6.1.4.1.164.12.3.2.1.4.1.7
A date-time in which the VC was created.
OBJECT-TYPE    
  DateAndTime  

atmConfVcOamSupport 1.3.6.1.4.1.164.12.3.2.1.4.1.8
OAM support mode, which determines the device location in a segment wise. endToEndAndSegment - In this mode the OAM cells are generated before the ABM (ATM Buffer Manager), so that the PCR and CDVT will not be affected.
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3), endToEndAndSegment(4)  

atmConfVcCCActivationCtrl 1.3.6.1.4.1.164.12.3.2.1.4.1.9
manual(1) - CC Activation process is disable activator(2) - ACE-101 initiate CC Activation process listener(3) - ACE-101 wait to CC Activation request from remote side.
OBJECT-TYPE    
  INTEGER manual(1), activator(2), listener(3)  

atmConfVcCCOperStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.10
initial (1) - The CC activation process is not started. up (2) - Continuity Check (CC) activated. down (3) - CC deactivated. source (4) - OAM CC(Continuity Check) of local agent activated. sink (5) - OAM CC of remote agent activated. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually.
OBJECT-TYPE    
  INTEGER initial(1), up(2), down(3), source(4), sink(5), both(8), timeout(9), denied(10), conflict(11), manual(12)  

atmConfVcLoopbackTraffic 1.3.6.1.4.1.164.12.3.2.1.4.1.11
This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmConfVcLoopbackFailureInd 1.3.6.1.4.1.164.12.3.2.1.4.1.12
This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2).
OBJECT-TYPE    
  INTEGER disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8)  

atmConfVcLoopbackFailureThreshold 1.3.6.1.4.1.164.12.3.2.1.4.1.13
The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1.
OBJECT-TYPE    
  Integer32  

atmConfVcOamDirection 1.3.6.1.4.1.164.12.3.2.1.4.1.14
The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream.
OBJECT-TYPE    
  INTEGER notApplicable(1), downStream(2), upStream(3)  

atmConfVcName 1.3.6.1.4.1.164.12.3.2.1.4.1.15
VC Name.
OBJECT-TYPE    
  DisplayString  

atmConfVcConnected 1.3.6.1.4.1.164.12.3.2.1.4.1.16
This object indicates whether this VC is connected and if connected, what is it connected to.
OBJECT-TYPE    
  INTEGER notConnected(1), mng(2), bridgePort(3), ds0Bundle(4)  

atmConfVcOamDescrIndex 1.3.6.1.4.1.164.12.3.2.1.4.1.17
This parameter indicates the VCL's OAM Descriptor index, according to the OAM Descriptor Configuration Table.
OBJECT-TYPE    
  Integer32  

atmNteLoopback 1.3.6.1.4.1.164.12.3.2.2
OBJECT IDENTIFIER    

atmLoopbackVpTable 1.3.6.1.4.1.164.12.3.2.2.1
This table contains parameters for an OAM VP loopback test.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpEntry

atmLoopbackVpEntry 1.3.6.1.4.1.164.12.3.2.2.1.1
An entry in table atmLoopbackVpTable.
OBJECT-TYPE    
  AtmLoopbackVpEntry  

atmLoopbackVpIfIndex 1.3.6.1.4.1.164.12.3.2.2.1.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpVpi 1.3.6.1.4.1.164.12.3.2.2.1.1.2
The VPI of the OAM VPL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpOperStatus 1.3.6.1.4.1.164.12.3.2.2.1.1.3
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpCDV 1.3.6.1.4.1.164.12.3.2.2.1.1.4
Cell Delay Variation for this sampling.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpAverageDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.5
Average delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMaxDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.6
Maximum delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMinDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.7
Minimum delay.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpErrSessions 1.3.6.1.4.1.164.12.3.2.2.1.1.8
Errored Sessions. Will be updated once in 5 seconds.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcTable 1.3.6.1.4.1.164.12.3.2.2.2
This table contains parameters for an OAM VC loopback test.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcEntry

atmLoopbackVcEntry 1.3.6.1.4.1.164.12.3.2.2.2.1
An entry in table.
OBJECT-TYPE    
  AtmLoopbackVcEntry  

atmLoopbackVcIfIndex 1.3.6.1.4.1.164.12.3.2.2.2.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVpi 1.3.6.1.4.1.164.12.3.2.2.2.1.2
The VPI of the OAM VCL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVci 1.3.6.1.4.1.164.12.3.2.2.2.1.3
The VCI of the OAM VCL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcOperStatus 1.3.6.1.4.1.164.12.3.2.2.2.1.4
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcCDV 1.3.6.1.4.1.164.12.3.2.2.2.1.5
Cell Delay Variation for this sampling.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcAverageDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.6
Average delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMaxDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.7
The maximum delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMinDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.8
The minimum delay.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcErrSessions 1.3.6.1.4.1.164.12.3.2.2.2.1.9
Errored Sessions. Will be updated once in 5 seconds.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlTable 1.3.6.1.4.1.164.12.3.2.2.3
This table contains parameters for an OAM VP loopback test, according interval number.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpIvlEntry

atmLoopbackVpIvlEntry 1.3.6.1.4.1.164.12.3.2.2.3.1
An entry in table.
OBJECT-TYPE    
  AtmLoopbackVpIvlEntry  

atmLoopbackVpIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.3.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlVpi 1.3.6.1.4.1.164.12.3.2.2.3.1.2
The VPI of the OAM VPL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlIvl 1.3.6.1.4.1.164.12.3.2.2.3.1.3
The relevant interval number.
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVpIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.3.1.4
-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK.
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpIvlCDV 1.3.6.1.4.1.164.12.3.2.2.3.1.5
Cell Delay Variation for this interval.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.6
Average delay without including lost cells for this interval.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.7
The maximum delay without including lost cells for this interval.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.8
The minimum delay for this interval.
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.3.1.9
Errored Sessions. Will be updated once in 5 seconds.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlTable 1.3.6.1.4.1.164.12.3.2.2.4
This table contains parameters for an OAM VC loopback test.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcIvlEntry

atmLoopbackVcIvlEntry 1.3.6.1.4.1.164.12.3.2.2.4.1
An entry in table.
OBJECT-TYPE    
  AtmLoopbackVcIvlEntry  

atmLoopbackVcIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.4.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVpi 1.3.6.1.4.1.164.12.3.2.2.4.1.2
The VPI of the OAM VCL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVci 1.3.6.1.4.1.164.12.3.2.2.4.1.3
The VCI of the OAM VCL.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlIvl 1.3.6.1.4.1.164.12.3.2.2.4.1.4
The relevant interval number.
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVcIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.4.1.5
-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK.
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcIvlCDV 1.3.6.1.4.1.164.12.3.2.2.4.1.6
Cell Delay Variation for this interval.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.7
Average delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.8
The maximum delay without including lost cells.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.9
The minimum delay.
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.4.1.10
Errored Sessions. Will be updated once in 5 seconds.
OBJECT-TYPE    
  Integer32  

atmNtePM 1.3.6.1.4.1.164.12.3.2.3
OBJECT IDENTIFIER    

atmVpPmTable 1.3.6.1.4.1.164.12.3.2.3.1
This table contains parameters for VP performance monitoring.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPmEntry

atmVpPmEntry 1.3.6.1.4.1.164.12.3.2.3.1.1
An entry in table.
OBJECT-TYPE    
  AtmVpPmEntry  

atmVpPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.1.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmVpPmVpi 1.3.6.1.4.1.164.12.3.2.3.1.1.2
The VPI of the Performance Monitoring VPL.
OBJECT-TYPE    
  Integer32  

atmVpPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.3
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVpPmDirection 1.3.6.1.4.1.164.12.3.2.3.1.1.4
The direction of PM.
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVpPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.1.1.5
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
OBJECT-TYPE    
  Integer32  

atmVpPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.6
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

atmVpPmSink 1.3.6.1.4.1.164.12.3.2.3.1.1.7
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVpPmSource 1.3.6.1.4.1.164.12.3.2.3.1.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmTable 1.3.6.1.4.1.164.12.3.2.3.2
This table contains parameters for VC performance monitoring.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPmEntry

atmVcPmEntry 1.3.6.1.4.1.164.12.3.2.3.2.1
An entry in table.
OBJECT-TYPE    
  AtmVcPmEntry  

atmVcPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.2.1.1
The interface index of the ATM layer.
OBJECT-TYPE    
  Integer32  

atmVcPmVpi 1.3.6.1.4.1.164.12.3.2.3.2.1.2
The VPI of the Performance Monitoring VCL.
OBJECT-TYPE    
  Integer32  

atmVcPmVci 1.3.6.1.4.1.164.12.3.2.3.2.1.3
The VCI of the PM VCL.
OBJECT-TYPE    
  Integer32  

atmVcPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.4
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVcPmDirection 1.3.6.1.4.1.164.12.3.2.3.2.1.5
The direction of PM.
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVcPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.2.1.6
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
OBJECT-TYPE    
  Integer32  

atmVcPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.7
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

atmVcPmSink 1.3.6.1.4.1.164.12.3.2.3.2.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmSource 1.3.6.1.4.1.164.12.3.2.3.2.1.9
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmNteMdl 1.3.6.1.4.1.164.12.3.3
OBJECT IDENTIFIER    

atmNteMdlConfig 1.3.6.1.4.1.164.12.3.3.1
OBJECT IDENTIFIER    

atmNteMdlConfigTable 1.3.6.1.4.1.164.12.3.3.1.1
Module configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteMdlConfigEntry

atmNteMdlConfigEntry 1.3.6.1.4.1.164.12.3.3.1.1.1
There is an entry in this table just for those modules that have parameters that are relevant to module level only.
OBJECT-TYPE    
  AtmNteMdlConfigEntry  

atmNteMdlSlotIndex 1.3.6.1.4.1.164.12.3.3.1.1.1.1
The slot number.
OBJECT-TYPE    
  Integer32 1..4  

atmNteMdlPrtCpuSharing 1.3.6.1.4.1.164.12.3.3.1.1.1.2
This object lets the user decide what will be the CPU sharing between the ports of the module. This object is applicable for modules in which the same CPU handles the traffic of all ports. equal - All ports will have the same CPU resource. port1 - Port 1 will have higher priority than the other ports.
OBJECT-TYPE    
  INTEGER equal(2), port1(3)  

atmNteMdlInputPriorityMechanism 1.3.6.1.4.1.164.12.3.3.1.1.1.3
This object allows the user to Enable/Disable the Input priority mechanism. This object is applicable for modules with more than one port, in which the total ports input may be greater than the port output. disabled - all LAN VCCs will be transmitted through the same queue (queue 1). Upon congestion frames will be dropped randomly. enabled - the user should configure each port/connection priority. Upon congestion frames will be dropped according to priority.
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

Defined Objects

AtmIfDataEntry  
SEQUENCE    
  Integer32 as atmIfTimeElapsed  
  Integer32 as atmIfValidIntervals  

AtmIfCurrentEntry  
SEQUENCE    
  Gauge32 as atmIfCurrentTxCells  
  Gauge32 as atmIfCurrentRxCells  
  Gauge32 as atmIfCurrentCorrectedHecs  
  Gauge32 as atmIfCurrentUncorrectedHecs  
  Gauge32 as atmIfCurrentHecErrorSeconds  

AtmIfIntervalEntry  
SEQUENCE    
  Integer32 as atmIfIntervalNumber  
  Gauge32 as atmIfIntervalTxCells  
  Gauge32 as atmIfIntervalRxCells  
  Gauge32 as atmIfIntervalCorrectedHecs  
  Gauge32 as atmIfIntervalUncorrectedHecs  
  Gauge32 as atmIfIntervalHecErrorSeconds  

AtmVpCurrentEntry  
SEQUENCE    
  Integer32 as atmVpCurrentVpi  
  Gauge32 as atmVpCurrentRxCellsClp01  
  Gauge32 as atmVpCurrentRxCellsClp0  
  Gauge32 as atmVpCurrentGcra0Violations  
  Gauge32 as atmVpCurrentGcra1Violations  
  Gauge32 as atmVpCurrentRxAIS  
  Gauge32 as atmVpCurrentTxAIS  
  Gauge32 as atmVpCurrentRxRDI  
  Gauge32 as atmVpCurrentTxRDI  
  Gauge32 as atmVpCurrentContinuityLoss  
  Gauge32 as atmVpCurrentUAS  
  Gauge32 as atmVpCurrentSES  
  Gauge32 as atmVpCurrentCDC  
  Gauge32 as atmVpCurrentTotalDiscards  
  Gauge32 as atmVpCurrentClp0Discards  
  Gauge32 as atmVpCurrentTotalCellOuts  
  Gauge32 as atmVpCurrentClp0CellOuts  
  Gauge32 as atmVpCurrentTaggedOuts  
  Gauge32 as atmVpCurrentPCR  
  Gauge32 as atmVpCurrentSCR  
  Gauge32 as atmVpCurrentMCR  
  Gauge32 as atmVpCurrentShaperTotalDiscards  
  Gauge32 as atmVpCurrentShaperClp0Discards  
  Gauge32 as atmVpCurrentShaperClp1Discards  

AtmVpPMCurrentEntry  
SEQUENCE    
  INTEGER as atmVpPMCurrentDir  
  Integer32 as atmVpPMCurrentVpi  
  Gauge32 as atmVpPMCurrentTxClp01  
  Gauge32 as atmVpPMCurrentTxClp0  
  Gauge32 as atmVpPMCurrentRxClp01  
  Gauge32 as atmVpPMCurrentRxClp0  
  Gauge32 as atmVpPMCurrentErroredCells  
  Gauge32 as atmVpPMCurrentLostCells  
  Gauge32 as atmVpPMCurrentMisinsertedCells  
  Gauge32 as atmVpPMCurrentECB  
  Gauge32 as atmVpPMCurrentSECB  
  Gauge32 as atmVpPMCurrentES  
  Gauge32 as atmVpPMCurrentSES  
  Gauge32 as atmVpPMCurrentUAS  
  INTEGER as atmVpPMCurrentIntervalQuality  
  INTEGER as atmVpPMCurrentLastDayQuality  

AtmVpIntervalEntry  
SEQUENCE    
  Integer32 as atmVpIntervalVpi  
  Integer32 as atmVpIntervalNumber  
  Gauge32 as atmVpIntervalRxCellsClp01  
  Gauge32 as atmVpIntervalRxCellsClp0  
  Gauge32 as atmVpIntervalGcra0Violations  
  Gauge32 as atmVpIntervalGcra1Violations  
  Gauge32 as atmVpIntervalRxAIS  
  Gauge32 as atmVpIntervalTxAIS  
  Gauge32 as atmVpIntervalRxRDI  
  Gauge32 as atmVpIntervalTxRDI  
  Gauge32 as atmVpIntervalContinuityLoss  
  Gauge32 as atmVpIntervalUAS  
  Gauge32 as atmVpIntervalSES  
  Gauge32 as atmVpIntervalCDC  
  Gauge32 as atmVpIntervalTotalDiscards  
  Gauge32 as atmVpIntervalClp0Discards  
  Gauge32 as atmVpIntervalTotalCellOuts  
  Gauge32 as atmVpIntervalClp0CellOuts  
  Gauge32 as atmVpIntervalTaggedOuts  
  Gauge32 as atmVpIntervalPCR  
  Gauge32 as atmVpIntervalSCR  
  Gauge32 as atmVpIntervalMCR  
  Gauge32 as atmVpIntervalShaperTotalDiscards  
  Gauge32 as atmVpIntervalShaperClp0Discards  
  Gauge32 as atmVpIntervalShaperClp1Discards  

AtmVpPMIntervalEntry  
SEQUENCE    
  Integer32 as atmVpPMIntervalVpi  
  INTEGER as atmVpPMIntervalDir  
  Integer32 as atmVpPMIntervalNumber  
  Gauge32 as atmVpPMIntervalTxClp01  
  Gauge32 as atmVpPMIntervalTxClp0  
  Gauge32 as atmVpPMIntervalRxClp01  
  Gauge32 as atmVpPMIntervalRxClp0  
  Gauge32 as atmVpPMIntervalErroredCells  
  Gauge32 as atmVpPMIntervalLostCells  
  Gauge32 as atmVpPMIntervalMisinsertedCells  
  Gauge32 as atmVpPMIntervalECB  
  Gauge32 as atmVpPMIntervalSECB  
  Gauge32 as atmVpPMIntervalES  
  Gauge32 as atmVpPMIntervalSES  
  Gauge32 as atmVpPMIntervalUAS  
  INTEGER as atmVpPMIntervalQuality  
  INTEGER as atmVpPMIntervalLastDayQuality  

AtmVpQoSEntry  
SEQUENCE    
  INTEGER as atmVpQoSPeriodRef  
  Integer32 as atmVpQoSElapsedTime  
  Gauge32 as atmVpQoSUAS  

AtmVpPMQoSEntry  
SEQUENCE    
  INTEGER as atmVpPMQoSDirection  
  INTEGER as atmVpPMQoSPeriodRef  
  Gauge32 as atmVpPMQoSCLR  
  Gauge32 as atmVpPMQoSCER  
  Gauge32 as atmVpPMQoSCMR  

AtmVpShaperStatEntry  
SEQUENCE    
  Counter32 as atmVpShaperDiscarded  
  Integer32 as atmVpShaperOccupation  
  Integer32 as atmVpShaperMaxOccupation  
  INTEGER as atmVpShaperLevel  
  Counter32 as atmVpShaperEpdDropped  
  Counter32 as atmVpShaperTotalEpdDropped  

AtmVcCurrentEntry  
SEQUENCE    
  Integer32 as atmVcCurrentVpi  
  Integer32 as atmVcCurrentVci  
  Gauge32 as atmVcCurrentRxCellsClp01  
  Gauge32 as atmVcCurrentRxCellsClp0  
  Gauge32 as atmVcCurrentGcra0Violations  
  Gauge32 as atmVcCurrentGcra1Violations  
  Gauge32 as atmVcCurrentRxAIS  
  Gauge32 as atmVcCurrentTxAIS  
  Gauge32 as atmVcCurrentRxRDI  
  Gauge32 as atmVcCurrentTxRDI  
  Gauge32 as atmVcCurrentContinuityLoss  
  Gauge32 as atmVcCurrentUAS  
  Gauge32 as atmVcCurrentSES  
  Gauge32 as atmVcCurrentCDC  
  Gauge32 as atmVcCurrentTotalDiscards  
  Gauge32 as atmVcCurrentClp0Discards  
  Gauge32 as atmVcCurrentTotalCellOuts  
  Gauge32 as atmVcCurrentClp0CellOuts  
  Gauge32 as atmVcCurrentTaggedOuts  
  Gauge32 as atmVcCurrentPCR  
  Gauge32 as atmVcCurrentSCR  
  Gauge32 as atmVcCurrentMCR  
  Gauge32 as atmVcCurrentShaperTotalDiscards  
  Gauge32 as atmVcCurrentShaperClp0Discards  
  Gauge32 as atmVcCurrentShaperClp1Discards  

AtmVcPMCurrentEntry  
SEQUENCE    
  Integer32 as atmVcPMCurrentVpi  
  Integer32 as atmVcPMCurrentVci  
  Integer32 as atmVcPMCurrentDir  
  Gauge32 as atmVcPMCurrentTxClp01  
  Gauge32 as atmVcPMCurrentTxClp0  
  Gauge32 as atmVcPMCurrentRxClp01  
  Gauge32 as atmVcPMCurrentRxClp0  
  Gauge32 as atmVcPMCurrentErroredCells  
  Gauge32 as atmVcPMCurrentLostCells  
  Gauge32 as atmVcPMCurrentMisinsertedCells  
  Gauge32 as atmVcPMCurrentECB  
  Gauge32 as atmVcPMCurrentSECB  
  Gauge32 as atmVcPMCurrentES  
  Gauge32 as atmVcPMCurrentSES  
  Gauge32 as atmVcPMCurrentUAS  
  INTEGER as atmVcPMCurrentIntervalQuality  
  INTEGER as atmVcPMCurrentLastDayQuality  

AtmVcIntervalEntry  
SEQUENCE    
  Integer32 as atmVcIntervalVpi  
  Integer32 as atmVcIntervalVci  
  Integer32 as atmVcIntervalNumber  
  Gauge32 as atmVcIntervalRxCellsClp01  
  Gauge32 as atmVcIntervalRxCellsClp0  
  Gauge32 as atmVcIntervalGcra0Violations  
  Gauge32 as atmVcIntervalGcra1Violations  
  Gauge32 as atmVcIntervalRxAIS  
  Gauge32 as atmVcIntervalTxAIS  
  Gauge32 as atmVcIntervalRxRDI  
  Gauge32 as atmVcIntervalTxRDI  
  Gauge32 as atmVcIntervalContinuityLoss  
  Gauge32 as atmVcIntervalUAS  
  Gauge32 as atmVcIntervalSES  
  Gauge32 as atmVcIntervalCDC  
  Gauge32 as atmVcIntervalTotalDiscards  
  Gauge32 as atmVcIntervalClp0Discards  
  Gauge32 as atmVcIntervalTotalCellOuts  
  Gauge32 as atmVcIntervalClp0CellOuts  
  Gauge32 as atmVcIntervalTaggedOuts  
  Gauge32 as atmVcIntervalPCR  
  Gauge32 as atmVcIntervalSCR  
  Gauge32 as atmVcIntervalMCR  
  Gauge32 as atmVcIntervalShaperTotalDiscards  
  Gauge32 as atmVcIntervalShaperClp0Discards  
  Gauge32 as atmVcIntervalShaperClp1Discards  

AtmVcPMIntervalEntry  
SEQUENCE    
  Integer32 as atmVcPMIntervalVpi  
  Integer32 as atmVcPMIntervalVci  
  INTEGER as atmVcPMIntervalDir  
  Integer32 as atmVcPMIntervalNumber  
  Gauge32 as atmVcPMIntervalTxClp01  
  Gauge32 as atmVcPMIntervalTxClp0  
  Gauge32 as atmVcPMIntervalRxClp01  
  Gauge32 as atmVcPMIntervalRxClp0  
  Gauge32 as atmVcPMIntervalErroredCells  
  Gauge32 as atmVcPMIntervalLostCells  
  Gauge32 as atmVcPMIntervalMisinsertedCells  
  Gauge32 as atmVcPMIntervalECB  
  Gauge32 as atmVcPMIntervalSECB  
  Gauge32 as atmVcPMIntervalES  
  Gauge32 as atmVcPMIntervalSES  
  Gauge32 as atmVcPMIntervalUAS  
  INTEGER as atmVcPMIntervalQuality  
  INTEGER as atmVcPMIntervalLastDayQuality  

AtmVcQoSEntry  
SEQUENCE    
  INTEGER as atmVcQoSPeriodRef  
  Integer32 as atmVcQoSElapsedTime  
  Gauge32 as atmVcQoSUAS  

AtmVcPMQoSEntry  
SEQUENCE    
  INTEGER as atmVcPMQoSDirection  
  INTEGER as atmVcPMQoSPeriodRef  
  Gauge32 as atmVcPMQoSCLR  
  Gauge32 as atmVcPMQoSCER  
  Gauge32 as atmVcPMQoSCMR  

AtmVcShaperStatEntry  
SEQUENCE    
  Counter32 as atmVcShaperDiscarded  
  Integer32 as atmVcShaperOccupation  
  Integer32 as atmVcShaperMaxOccupation  
  INTEGER as atmVcShaperLevel  
  Counter32 as atmVcShaperEpdDropped  
  Counter32 as atmVcShaperTotalEpdDropped  

AtmIntervalDateEntry  
SEQUENCE    
  Integer32 as atmIntervalDateInterval  
  DisplayString as atmIntervalDateDate  
  DisplayString as atmIntervalDateTime  

AtmNteManagerEntry  
SEQUENCE    
  IpAddress as atmNteManagerIP  
  Integer32 as atmNteManagerPvc  
  Integer32 as atmNteManagerIfIndex  
  Integer32 as atmNteManagerVpi  
  Integer32 as atmNteManagerVci  
  Integer32 as atmNteManagerTrapMask  
  RowStatus as atmNteManagerRowStatus  
  IpAddress as atmNteManagerNextHop  
  INTEGER as atmNteManagerVlanSupport  
  Integer32 as atmNteManagerVlanIdentifier  
  Integer32 as atmNteManagerVlanFramePriority  
  OCTET STRING as atmNteManagerAlarmTrapMask  
  Integer32 as atmNteManagerConfigPorts  

AtmNteConfOamIfEntry  
SEQUENCE    
  INTEGER as atmNteConfOamIfAisRdi  

AtmNteHostIfEntry  
SEQUENCE    
  Integer32 as atmNteHostPvcIndex  
  IpAddress as atmNteHostIP  
  IpAddress as atmNteHostMask  
  Integer32 as atmNteHostAtmIfIndex  
  Integer32 as atmNteHostVpi  
  Integer32 as atmNteHostVci  
  RowStatus as atmNteHostRowStatus  
  Integer32 as atmNteHostRdnVpi  
  Integer32 as atmNteHostRdnVci  
  IpAddress as atmNteHostDefaultNextHop  
  INTEGER as atmNteHostVlanTagging  
  Integer32 as atmNteHostDefaultVlanID  
  Integer32 as atmNteHostDefaultVlanPriority  

AtmNteOamEntry  
SEQUENCE    
  INTEGER as atmNteOamMode  
  INTEGER as atmNteOamCellType  
  INTEGER as atmNteOamLevel  
  INTEGER as atmNteOamEnable  

AtmAlarmForwardingEntry  
SEQUENCE    
  Integer32 as atmAlarmForwardingFailPort  
  Integer32 as atmAlarmForwardingToPort  
  RowStatus as atmAlarmForwardingRowStatus  
  BITS as atmAlarmForwardingFailureLevel  
  INTEGER as atmAlarmForwardingRecoveryMode  
  INTEGER as atmAlarmForwardingRecoveryCommand  

AtmVpCrossConnectExtenEntry  
SEQUENCE    
  SnmpAdminString as atmVpCrossConnectName  

AtmVcCrossConnectExtenEntry  
SEQUENCE    
  SnmpAdminString as atmVcCrossConnectName  

AtmNteIdEntry  
SEQUENCE    
  Integer32 as atmNteIdIndex  
  Integer32 as atmNteUnitId  
  DisplayString as atmNteUnitVersion  
  INTEGER as atmNteCardType  
  INTEGER as atmNteCardStatus  
  INTEGER as atmNteCardCmd  

AtmSysIntervalEntry  
SEQUENCE    
  Integer32 as atmSysIntervalNumber  
  Gauge32 as atmSysIntervalCdc  

AtmLoopbackVpEntry  
SEQUENCE    
  Integer32 as atmLoopbackVpIfIndex  
  Integer32 as atmLoopbackVpVpi  
  INTEGER as atmLoopbackVpOperStatus  
  Integer32 as atmLoopbackVpCDV  
  Integer32 as atmLoopbackVpAverageDelay  
  Integer32 as atmLoopbackVpMaxDelay  
  Integer32 as atmLoopbackVpMinDelay  
  Integer32 as atmLoopbackVpErrSessions  

AtmLoopbackVcEntry  
SEQUENCE    
  Integer32 as atmLoopbackVcIfIndex  
  Integer32 as atmLoopbackVcVpi  
  Integer32 as atmLoopbackVcVci  
  INTEGER as atmLoopbackVcOperStatus  
  Integer32 as atmLoopbackVcCDV  
  Integer32 as atmLoopbackVcAverageDelay  
  Integer32 as atmLoopbackVcMaxDelay  
  Integer32 as atmLoopbackVcMinDelay  
  Integer32 as atmLoopbackVcErrSessions  

AtmLoopbackVpIvlEntry  
SEQUENCE    
  Integer32 as atmLoopbackVpIvlIfIndex  
  Integer32 as atmLoopbackVpIvlVpi  
  Integer32 as atmLoopbackVpIvlIvl  
  INTEGER as atmLoopbackVpIvlOperStatus  
  Integer32 as atmLoopbackVpIvlCDV  
  Integer32 as atmLoopbackVpIvlAverageDelay  
  Integer32 as atmLoopbackVpIvlMaxDelay  
  Integer32 as atmLoopbackVpIvlMinDelay  
  Integer32 as atmLoopbackVpIvlErrSessions  

AtmLoopbackVcIvlEntry  
SEQUENCE    
  Integer32 as atmLoopbackVcIvlIfIndex  
  Integer32 as atmLoopbackVcIvlVpi  
  Integer32 as atmLoopbackVcIvlVci  
  Integer32 as atmLoopbackVcIvlIvl  
  INTEGER as atmLoopbackVcIvlOperStatus  
  Integer32 as atmLoopbackVcIvlCDV  
  Integer32 as atmLoopbackVcIvlAverageDelay  
  Integer32 as atmLoopbackVcIvlMaxDelay  
  Integer32 as atmLoopbackVcIvlMinDelay  
  Integer32 as atmLoopbackVcIvlErrSessions  

AtmVpPmEntry  
SEQUENCE    
  Integer32 as atmVpPmIfIndex  
  Integer32 as atmVpPmVpi  
  INTEGER as atmVpPmAdminStatus  
  INTEGER as atmVpPmDirection  
  Integer32 as atmVpPmBlockSize  
  RowStatus as atmVpPmRowStatus  
  INTEGER as atmVpPmSink  
  INTEGER as atmVpPmSource  

AtmVcPmEntry  
SEQUENCE    
  Integer32 as atmVcPmIfIndex  
  Integer32 as atmVcPmVpi  
  Integer32 as atmVcPmVci  
  INTEGER as atmVcPmAdminStatus  
  INTEGER as atmVcPmDirection  
  Integer32 as atmVcPmBlockSize  
  RowStatus as atmVcPmRowStatus  
  INTEGER as atmVcPmSink  
  INTEGER as atmVcPmSource  

AtmNteMdlConfigEntry  
SEQUENCE    
  Integer32 as atmNteMdlSlotIndex  
  INTEGER as atmNteMdlPrtCpuSharing  
  INTEGER as atmNteMdlInputPriorityMechanism  

AtmGenSysSelfTestEntry  
SEQUENCE    
  Integer32 as atmGenSysSelfTestIndex  
  DisplayString as atmGenSysSelfTestResult  

AtmGenSysLogEntry  
SEQUENCE    
  Integer32 as atmGenSysLogIndex  
  DisplayString as atmGenSysLogMessage  

AtmGenSysCxRefEntry  
SEQUENCE    
  Integer32 as atmGenSysCxRefIndex  
  Gauge32 as atmGenSysCxRefCounter  

AtmCESAAL1StatsEntry  
SEQUENCE    
  Counter32 as atmCESAAL1SeqErrors  
  Counter32 as atmCESAAL1HdrErrors  
  Counter32 as atmCESAAL1PointerReframes  
  Counter32 as atmCESAAL1BufUnderflows  
  Counter32 as atmCESAAL1BufOverflows  

AtmNteConfVcEntry  
SEQUENCE    
  INTEGER as atmConfVcPolicing  
  INTEGER as atmConfVcCCAdminStatus  
  INTEGER as atmConfVcLoopbackAdminStatus  
  OCTET STRING as atmConfVcLoopbackSinkAddress  
  OCTET STRING as atmConfVcCongestionControl  
  INTEGER as atmConfVcCCDirection  
  DateAndTime as atmConfVcCreationTime  
  INTEGER as atmConfVcOamSupport  
  INTEGER as atmConfVcCCActivationCtrl  
  INTEGER as atmConfVcCCOperStatus  
  INTEGER as atmConfVcLoopbackTraffic  
  INTEGER as atmConfVcLoopbackFailureInd  
  Integer32 as atmConfVcLoopbackFailureThreshold  
  INTEGER as atmConfVcOamDirection  
  DisplayString as atmConfVcName  
  INTEGER as atmConfVcConnected  
  Integer32 as atmConfVcOamDescrIndex